Insulating Suspended Ceilings

Insulation installed in a suspended ceiling does not meet the infiltration requirements of the International Energy Conservation Code. When the insulation is on the suspended ceiling, the ceiling is defined as part of the building envelope. This requires that it be air-sealed like any other envelope component.