COMcheck Desktop 4.0.7

What’s new: 

Version 4.0.7.2 addresses the following:

  • 90.1-2013 and 2016: Corrected an issue where split system AC < 65 kBtu/h was misreporting requirement as 14.0 SEER. Changed it to 13.00 SEER.
  • Corrected an issue where reports were missing "state" output in header section if not performance based projects
  • Resized the output of "notes" (from Project details) to prevent it from running off the right side of envelope report
  • Ontario SB-10 upgraded in COMcheck to SB-10-2017 version; it is based on 90.1-2013

Version 4.0.7.1 addresses the following:

  • 90.1-2016 Code: Removed the restriction that there is a roof and floor. Only a wall is now required.
  • 90.1-2013 Code: Corrected an issue with updating entries in edit mode.
  • 90.1-2013 Code: New Constructions: Added a absolute limit on slab-on-grade feet. Must be less than roof area. (all energy codes). Addition projects can have any size slab.
  • Added a window area adjustment mechanism so that curtain windows that are exactly same size as wall gross area are downsized by 0.5 sf so they simulate.
  • 90.1-2103: Corrected an issue where multiple surfaces with multiple windows were not getting assigned to the parent surface of the window. This sometimes causes windows to fail to fit in the surface and SketchUp couldn't draw the windows.
  • Corrected an issue with calls to the zoneList. Changed AdjustNetArea so it works on a parameter LIST called into function. Impacts 2013/2016 projects.
  • 2015 IECC: Corrected an issue that mistakenly caused the evaluation for economizer to think it is a fan based piece of equipment.
  • Corrected an issue with economizer requirements for 2015 IECC which were excluding the "excepted" capacity for exceptions other than exception 2. When calculating total system capacity it should not exclude these. This was released in 4.0.7.0 for 2012 IECC.

Version 4.0.7.0 addresses the following:

  • Support for ASHRAE 90.1-2016 is now included
  • Service water heating input rating units have been modified to be consistent between the user interface and report output
  • New York City metal building standing seam roof assembly processing has been modified to remove a program shutdown problem when generating reports with that assembly type specified
Version: 
4.0.7
Build: 
4.0.7.2
Release date: 
Monday, November 20, 2017
Platform: 
Windows
Logo: