The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. This suite of ASHRAE Standard 90.1 prototype buildings covers all the Reference Building types except supermarket, and also adds a new building prototype representing high-rise apartment buildings.The prototype models include 16 building types in 19 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. This combination leads to a set of 1824 building models (in EnergyPlus Version 8.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling...
Publications
To receive updates about BECP publications subscribe to the BECP Mailing List.
Additional resources are also available from the Building America Solution Center.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Full Service Restaurant building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the High-rise Apartment building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Hospital building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Large Hotel building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Large Office building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Mid-rise Apartment building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Outpatient Healthcare building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Primary School building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Quick Service Restaurant building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Secondary School building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Small Hotel building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Small Office building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Stand Alone Retail building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Retail Strip Mall building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Warehouse (non-refrigerated) building type.
The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007, 90.1-2010, 90.1-2013, 90.1-2016, and 90.1-2019. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Medium Office building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Full Service Restaurant building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Strip Mall building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. This combination leads to a set of 1520 building models (in EnergyPlus Version 8.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the High-rise Apartment building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Hospital building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Large Office building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Medium Office building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Mid-rise Apartment building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Outpatient Healthcare building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Primary School building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Quick Service Restaurant building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Secondary School building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Small Hotel building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Small Office building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Stand-alone Retail building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Warehouse (non-refrigerated) building type.
The commercial IECC prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. The prototype models include 16 building types in 19 climate locations for the 2006 IECC, 2009 IECC, 2012 IECC, 2015 IECC and 2018 IECC. Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the building descriptions, thermal zone internal loads, schedules and other key modeling input information.
The following files are for the Large Hotel building type.
EnergyPlus TMY3 weather files for 17 climate locations associated with the ASHRAE Standard 90.1 and IECC Prototype Building Models.
See the Commercial Prototype Building Models page for the individual weather data files listed by Climate Zone. Updated file posted 10/22/18.
See the Residential Prototype Building Models page for the individual weather data files listed by Climate Zone. New file posted 5/24/21.
Since the last publication of the commercial prototype building models, PNNL has made numerous enhancements to the original prototype models compliant with the 2004, 2007, and 2010 editions of Standard 90.1. Those enhancements are described here and were made for several reasons: (1) to change or improve prototype design assumptions; (2) to improve simulation accuracy; (3) to improve simulation infrastructure; and (4) to add additional detail to the models needed to capture certain energy impacts from Standard 90.1 improvements.
The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the 2006, 2009 and 2012 versions of the IECC are available for each state.
Complete IECC Prototype Building Model packages include files for every state by IECC version.
Each ZIP file includes EnergyPlus model input files (.idf) and corresponding output files (.html).
Note: each of these files are over 100 MB in size; download times may vary.
The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the 2006, 2009 and 2012 versions of the IECC are available for each state.
This set of IECC Prototype Building Models is for the state of Vermont, using a customized version of the 2009 IECC as the baseline code with better slab insulation and windows and tighter duct sealing.
Each ZIP file includes EnergyPlus model input files (.idf) and corresponding output files (.html).
This speadsheet provides a summary of the percentage of energy savings with plug loads for the ASHRAE Standard 90.1 Prototype Building Models.