Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: International Falls Intl Ap MN USA TMY3 WMO#=727470

Simulation Timestamp: 2018-10-19 09:20:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 2202.10 702.51 779.79
Net Site Energy 2202.10 702.51 779.79
Total Source Energy 5439.82 1735.40 1926.30
Net Source Energy 5439.82 1735.40 1926.30


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 736.55 0.00 0.00 0.00 0.00
Cooling 74.23 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.38 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 207.67 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 467.85 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1465.55 736.55 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 736.55 0.00 0.00 0.00 0.00
Cooling General 74.23 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.38 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 207.67 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 467.85 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.37 0.00 0.00 0.00 0.00 0.00
HVAC 265.49 260.82 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 518.97 260.82 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.20 0.00 0.00 0.00 0.00 0.00
HVAC 239.18 234.97 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 467.54 234.97 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1465.55 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1465.55 100.00
     
Total On-Site and Utility Electric Sources 1465.55 100.00
Total Electricity End Uses 1465.55 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 33.00
Time Setpoint Not Met During Occupied Cooling 4.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 4097.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod International Falls Intl Ap MN USA TMY3 WMO#=727470
Weather File International Falls Intl Ap MN USA TMY3 WMO#=727470
Latitude [deg] 48.57
Longitude [deg] -93.4
Elevation [m] 359.00
Time Zone -6.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 29-JUN-17:30 04-JAN-05:00 - - - 01-JAN-07:15
Heating 0.00 133527.51 0.00 0.00 0.00 0.00
Cooling 23830.29 0.00 0.00 0.00 0.00 0.00
Interior Lighting 8572.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 6585.31 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 26850.23 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 92295.01 133527.51 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 133527.51 0.00 0.00 0.00 0.00
Cooling General 23830.29 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7168.38 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1404.40 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 6585.31 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 26850.23 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 798.42 0.00 0.00 0.00
Cooling 235.09 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 124.72 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 657.70 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1481.67 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4641.40 798.42 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 282.73 0.00 0.00 0.00
Cooling 83.25 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.16 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 232.90 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 524.67 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1643.57 282.73 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 282.73 0.00 0.00 0.00
Cooling 83.25 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.16 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 232.90 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 524.67 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1643.57 282.73 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB -32.70 0.00 -32.70 Wetbulb [C] 2.40 210.00
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 30.10 12.40 21.10 Wetbulb [C] 4.70 200.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.238 0.247 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.238 0.247 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.238 0.247 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.238 0.247 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.238 0.247 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.238 0.247 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.238 0.247 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.238 0.247 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.238 0.247 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.238 0.247 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.238 0.247 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.238 0.247 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.238 0.247 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.238 0.247 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.238 0.247 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.238 0.247 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.238 0.247 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.238 0.247 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.238 0.247 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.238 0.247 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.238 0.247 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.238 0.247 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.238 0.247 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.238 0.247 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.238 0.247 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.238 0.247 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.238 0.247 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.238 0.247 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.42_SHGC_0.45 3.32 0.00 0.00 3.32 3.32 2.493 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 2.23 2.493 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.493 0.426 0.308              
North Total or Average           112.97 2.493 0.426 0.308              
Non-North Total or Average           193.95 2.493 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.64 83.64 39.38
Exterior Lighting Total 2508.33           39.38



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   2852.73 2194.50 658.24 0.77 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   2631.97 2024.80 607.18 0.77 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   7265.92 5802.97 1462.95 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   1938.11 1456.36 481.75 0.75 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1680.49 1255.44 425.05 0.75 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1663.67 1241.52 422.15 0.75 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2089.71 1536.10 553.61 0.74 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2134.84 1575.65 559.20 0.74 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   7862.37 6175.51 1686.86 0.79 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   7204.60 5646.99 1557.62 0.78 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7391.42 5688.25 1703.17 0.77 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   5629.85 4349.95 1279.89 0.77 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4746.07 3653.92 1092.14 0.77 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4717.02 3629.65 1087.38 0.77 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5921.50 4495.09 1426.41 0.76 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5928.24 4505.92 1422.32 0.76 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5190.96 4078.16 1112.80 0.79 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   4580.55 3615.35 965.20 0.79 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   4923.47 3845.25 1078.21 0.78 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   3789.52 2899.91 889.61 0.77 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3001.73 2330.85 670.88 0.78 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2968.82 2303.33 665.49 0.78 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4174.64 3246.52 928.11 0.78 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4188.61 3258.19 930.42 0.78 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 2728.3 3.18 10.85 11.28 10.63
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2517.2 3.18 10.85 11.28 10.63
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 6921.9 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 1858.0 3.21 10.95 11.40 10.79
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1611.9 3.22 10.98 11.42 10.83
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1596.0 3.22 10.99 11.43 10.84
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2007.7 3.24 11.05 11.51 10.94
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2050.2 3.23 11.04 11.49 10.91
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 7503.3 3.15 10.75 11.17 10.49
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 6877.1 3.15 10.76 11.18 10.50
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7068.8 3.18 10.84 11.28 10.63
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 5381.9 3.17 10.83 11.26 10.60
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4538.7 3.18 10.84 11.27 10.62
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4511.2 3.18 10.84 11.28 10.63
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5670.9 3.20 10.91 11.34 10.72
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5676.6 3.19 10.90 11.34 10.71
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 4953.8 3.15 10.75 11.17 10.49
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 4369.2 3.14 10.73 11.15 10.46
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 4701.4 3.16 10.78 11.20 10.53
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 3626.2 3.19 10.87 11.30 10.67
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2868.1 3.17 10.80 11.23 10.57
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2836.9 3.17 10.81 11.24 10.57
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3988.1 3.16 10.80 11.22 10.56
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4001.4 3.16 10.79 11.22 10.55
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   4027.69 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   3954.03 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   7039.97 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   3942.11 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   3126.02 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   3125.76 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   3143.66 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   3280.44 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   7524.13 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   7481.90 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   7492.93 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   7450.66 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   5459.39 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   5458.65 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   5504.87 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   5504.14 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   5731.77 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   5711.44 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   5715.06 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   5694.71 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   4647.24 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   4646.83 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   4666.35 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   4665.94 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.16 177.60 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 163.88 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.44 491.65 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 114.30 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.09 97.76 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.09 96.53 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 116.95 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.11 120.65 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.46 512.91 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.42 467.81 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.41 460.59 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 354.01 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 296.02 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 293.85 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 357.59 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 359.05 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 338.80 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 302.05 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 317.16 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.21 233.12 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 190.87 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 188.42 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 266.36 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 267.40 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1616.85 1940.22 0.132 0.159 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 27.12 0.01270
G NW APARTMENT 1491.92 1790.30 0.122 0.146 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 26.19 0.01270
OFFICE 4387.22 5264.67 0.366 0.439 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 09:00:00 23.28 0.01270
G NE APARTMENT 1040.57 1248.68 0.085 0.102 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 25.26 0.01270
G N1 APARTMENT 889.95 1067.94 0.073 0.087 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 24.92 0.01270
G N2 APARTMENT 878.78 1054.54 0.072 0.086 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 24.92 0.01270
G S1 APARTMENT 1064.68 1277.62 0.087 0.104 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.95 0.01270
G S2 APARTMENT 1098.35 1318.02 0.090 0.108 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 29.79 0.01270
M SW APARTMENT 4669.40 5603.29 0.382 0.458 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 27.12 0.01270
M NW APARTMENT 4258.83 5110.60 0.348 0.418 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 26.19 0.01270
M SE APARTMENT 4192.95 5031.54 0.343 0.411 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 29.79 0.01270
M NE APARTMENT 3222.69 3867.23 0.263 0.316 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.85 0.01270
M N1 APARTMENT 2694.87 3233.84 0.220 0.264 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 24.92 0.01270
M N2 APARTMENT 2675.17 3210.20 0.219 0.262 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 24.92 0.01270
M S1 APARTMENT 3255.39 3906.47 0.266 0.319 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 30.10 0.01270
M S2 APARTMENT 3268.67 3922.40 0.267 0.321 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.95 0.01270
T SW APARTMENT 3084.21 3701.05 0.252 0.302 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 29.54 0.01270
T NW APARTMENT 2749.72 3299.66 0.225 0.270 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 27.12 0.01270
T SE APARTMENT 2887.15 3464.58 0.236 0.283 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.95 0.01270
T NE APARTMENT 2122.13 2546.56 0.173 0.208 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 30.10 0.01270
T N1 APARTMENT 1737.69 2085.23 0.142 0.170 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 26.19 0.01270
T N2 APARTMENT 1715.36 2058.43 0.140 0.168 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 26.19 0.01270
T S1 APARTMENT 2424.85 2909.82 0.198 0.238 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 30.10 0.01270
T S2 APARTMENT 2434.31 2921.17 0.199 0.239 INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 30.10 0.01270


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1971.21 2365.45 0.059 0.071 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G NW APARTMENT 1959.34 2351.21 0.059 0.071 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
OFFICE 3969.12 4762.94 0.115 0.139 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G NE APARTMENT 1949.27 2339.12 0.059 0.070 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G N1 APARTMENT 1259.13 1510.96 0.038 0.045 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G N2 APARTMENT 1258.91 1510.69 0.038 0.045 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G S1 APARTMENT 1274.05 1528.86 0.038 0.046 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
G S2 APARTMENT 1389.72 1667.66 0.042 0.050 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -32.70 0.00018
M SW APARTMENT 3594.09 4312.91 0.108 0.130 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M NW APARTMENT 3558.38 4270.06 0.107 0.128 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M SE APARTMENT 3567.71 4281.25 0.107 0.129 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M NE APARTMENT 3531.96 4238.35 0.106 0.127 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M N1 APARTMENT 1848.00 2217.60 0.055 0.067 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M N2 APARTMENT 1847.38 2216.85 0.055 0.067 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M S1 APARTMENT 1886.46 2263.75 0.057 0.068 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
M S2 APARTMENT 1885.84 2263.01 0.057 0.068 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T SW APARTMENT 3462.75 4155.30 0.104 0.125 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T NW APARTMENT 3445.55 4134.67 0.103 0.124 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T SE APARTMENT 3448.61 4138.34 0.104 0.124 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T NE APARTMENT 3431.41 4117.69 0.103 0.124 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T N1 APARTMENT 2545.58 3054.70 0.076 0.092 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T N2 APARTMENT 2545.24 3054.28 0.076 0.092 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T S1 APARTMENT 2561.74 3074.09 0.077 0.092 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018
T S2 APARTMENT 2561.40 3073.68 0.077 0.092 INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -32.70 0.00018


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.16 0.16 0.07 0.07
SPLIT GNW 0.15 0.15 0.07 0.07
SPLIT OFFICE 0.44 0.44 0.14 0.14
SPLIT GNE 0.10 0.10 0.07 0.07
SPLIT GN1 0.09 0.09 0.05 0.05
SPLIT GN2 0.09 0.09 0.05 0.05
SPLIT GS1 0.10 0.10 0.05 0.05
SPLIT GS2 0.11 0.11 0.05 0.05
SPLIT MSW 0.46 0.46 0.13 0.13
SPLIT MNW 0.42 0.42 0.13 0.13
SPLIT MSE 0.41 0.41 0.13 0.13
SPLIT MNE 0.32 0.32 0.13 0.13
SPLIT MN1 0.26 0.26 0.07 0.07
SPLIT MN2 0.26 0.26 0.07 0.07
SPLIT MS1 0.32 0.32 0.07 0.07
SPLIT MS2 0.32 0.32 0.07 0.07
SPLIT TSW 0.30 0.30 0.12 0.12
SPLIT TNW 0.27 0.27 0.12 0.12
SPLIT TSE 0.28 0.28 0.12 0.12
SPLIT TNE 0.21 0.21 0.12 0.12
SPLIT TN1 0.17 0.17 0.09 0.09
SPLIT TN2 0.17 0.17 0.09 0.09
SPLIT TS1 0.24 0.24 0.09 0.09
SPLIT TS2 0.24 0.24 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 4290.25 6665.25 2988.75
G NW APARTMENT 4631.50 6937.00 3529.50
OFFICE 795.50 1658.50 655.75
G NE APARTMENT 4607.50 7045.50 3552.75
G N1 APARTMENT 4072.25 7135.00 3213.50
G N2 APARTMENT 4070.75 7138.25 3217.50
G S1 APARTMENT 3590.00 6701.50 2438.25
G S2 APARTMENT 3751.25 6743.25 2652.25
M SW APARTMENT 3907.00 5102.75 1437.00
M NW APARTMENT 4346.25 5538.00 2081.75
M SE APARTMENT 3897.00 5113.50 1416.75
M NE APARTMENT 4379.25 5574.50 2092.00
M N1 APARTMENT 3702.25 5455.00 1533.00
M N2 APARTMENT 3701.25 5461.75 1532.00
M S1 APARTMENT 2870.00 4944.50 489.00
M S2 APARTMENT 2875.25 4944.25 490.50
T SW APARTMENT 5213.00 5886.75 3188.75
T NW APARTMENT 5513.25 6209.50 3703.00
T SE APARTMENT 5202.50 5885.50 3164.75
T NE APARTMENT 5499.00 6288.50 3701.50
T N1 APARTMENT 5219.50 6285.00 3439.25
T N2 APARTMENT 5219.00 6296.50 3443.50
T S1 APARTMENT 4835.50 5837.50 2835.25
T S2 APARTMENT 4836.00 5836.50 2834.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 6390.75 7268.75 4097.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.75 0.00 0.75 0.00
G NW APARTMENT 5.50 0.00 5.50 0.00
OFFICE 23.50 0.00 0.00 0.00
G NE APARTMENT 2.25 0.00 2.25 0.00
G N1 APARTMENT 3.00 0.25 3.00 0.25
G N2 APARTMENT 1.75 0.25 1.75 0.25
G S1 APARTMENT 1.25 0.00 1.25 0.00
G S2 APARTMENT 0.50 0.00 0.50 0.00
M SW APARTMENT 1.50 0.00 1.50 0.00
M NW APARTMENT 2.00 0.00 2.00 0.00
M SE APARTMENT 1.00 0.00 1.00 0.00
M NE APARTMENT 0.50 0.00 0.50 0.00
M N1 APARTMENT 0.50 0.00 0.50 0.00
M N2 APARTMENT 0.75 0.00 0.75 0.00
M S1 APARTMENT 0.25 0.00 0.25 0.00
M S2 APARTMENT 1.00 0.00 1.00 0.00
T SW APARTMENT 1.25 0.00 1.25 0.00
T NW APARTMENT 1.50 0.00 1.50 0.00
T SE APARTMENT 1.50 0.00 1.50 0.00
T NE APARTMENT 1.25 0.00 1.25 0.00
T N1 APARTMENT 3.00 3.75 3.00 3.75
T N2 APARTMENT 3.25 4.50 3.25 4.50
T S1 APARTMENT 1.25 0.00 1.25 0.00
T S2 APARTMENT 1.50 0.00 1.50 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 56.50 4.75 33.00 4.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.366 0.098 0.000 0.063
G NW APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.060
OFFICE 0.94 1.00 268.97 0.518 0.119 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.060
G N1 APARTMENT 1.71 2.50 268.97 0.353 0.059 0.000 0.060
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.059 0.000 0.060
G S1 APARTMENT 1.71 2.50 268.97 0.353 0.059 0.000 0.062
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.059 0.000 0.062
M SW APARTMENT 1.71 2.50 268.97 0.353 0.141 0.000 0.076
M NW APARTMENT 1.71 2.50 268.97 0.353 0.141 0.000 0.072
M SE APARTMENT 1.71 2.50 268.97 0.353 0.141 0.000 0.076
M NE APARTMENT 1.71 2.50 268.97 0.353 0.141 0.000 0.072
M N1 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.072
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.072
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.076
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.076
T SW APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.090
T NW APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.086
T SE APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.090
T NE APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.086
T N1 APARTMENT 1.71 2.50 268.97 0.353 0.113 0.000 0.085
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.113 0.000 0.085
T S1 APARTMENT 1.71 2.50 268.97 0.353 0.113 0.000 0.090
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.113 0.000 0.090
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.353 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.499 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.362 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 467.85 0.00 01-JAN-00:15 33119.05 27-FEB-07:15
WaterSystems:Electricity 467.85 0.00 01-JAN-00:15 33119.05 27-FEB-07:15
Water Heater:WaterSystems:Electricity 467.85 0.00 01-JAN-00:15 33119.05 27-FEB-07:15
Fans:Electricity 207.67 6585.31 04-JAN-03:00 6585.31 01-JAN-06:30
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
ElectricityPurchased:Plant 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
Cogeneration:ElectricityPurchased 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
ElectricityNet:Plant 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
Cogeneration:ElectricityNet 1465.55 19955.61 01-JAN-03:15 92295.01 29-JUN-17:30
ExteriorLights:Electricity 39.38 0.00 01-JAN-08:15 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.38 0.00 01-JAN-08:15 2508.33 01-JAN-00:15
Electricity:HVAC 281.90 6585.31 04-JAN-03:00 31511.87 29-JUN-16:00
General:Fans:Electricity 207.67 6585.31 04-JAN-03:00 6585.31 01-JAN-06:30
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 74.23 0.00 01-JAN-00:15 24926.56 29-JUN-16:00


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 736.55 0.00 10-APR-15:30 133527.51 04-JAN-06:00
Gas:HVAC 736.55 0.00 10-APR-15:30 133527.51 04-JAN-06:00
Heating:Gas 736.55 0.00 10-APR-15:30 133527.51 04-JAN-06:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1484.04 1403.36 07-OCT-13:15 170995.94 04-JAN-06:00
EnergyTransfer:Building 591.12 1351.82 07-OCT-13:30 64173.93 04-JAN-06:00
EnergyTransfer:Zone:G SW APARTMENT 14.99 0.02 16-MAY-09:15 2012.06 04-JAN-08:15
Heating:EnergyTransfer 266.88 0.00 19-MAR-16:15 64173.93 04-JAN-06:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 9.08 0.00 06-JAN-14:00 2012.06 04-JAN-08:15
Cooling:EnergyTransfer 324.24 0.00 01-JAN-07:45 58613.96 30-JUN-17:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 5.92 0.00 01-JAN-00:15 1759.50 01-SEP-15:30
EnergyTransfer:Zone:G NW APARTMENT 15.96 0.01 23-APR-00:45 2275.04 04-JAN-12:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 11.66 0.00 08-FEB-16:15 2275.04 04-JAN-12:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.30 0.00 01-JAN-00:15 1621.49 30-JUN-18:15
EnergyTransfer:Zone:OFFICE 22.18 0.19 07-OCT-11:00 4284.30 24-DEC-07:30
Heating:EnergyTransfer:Zone:OFFICE 1.08 0.00 01-JAN-00:15 4284.30 24-DEC-07:30
Cooling:EnergyTransfer:Zone:OFFICE 21.10 0.00 01-JAN-07:45 3142.68 24-JUL-13:30
EnergyTransfer:Zone:G NE APARTMENT 15.99 0.19 15-MAY-19:15 2180.56 04-JAN-12:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 11.53 0.00 19-MAR-16:15 2180.56 04-JAN-12:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.46 0.00 01-JAN-00:15 1116.90 29-JUN-19:00
EnergyTransfer:Zone:G N1 APARTMENT 10.58 0.04 28-MAY-11:30 1383.72 04-JAN-12:00
Heating:EnergyTransfer:Zone:G N1 APARTMENT 6.38 0.00 29-JAN-17:15 1383.72 04-JAN-12:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 4.21 0.00 01-JAN-00:15 932.94 29-JUN-19:00
EnergyTransfer:Zone:G N2 APARTMENT 10.58 0.02 08-OCT-00:15 1380.23 04-JAN-12:00
Heating:EnergyTransfer:Zone:G N2 APARTMENT 6.37 0.00 04-FEB-18:15 1380.23 04-JAN-12:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 4.20 0.00 01-JAN-00:15 920.73 29-JUN-19:00
EnergyTransfer:Zone:G S1 APARTMENT 10.20 0.04 26-MAR-23:15 1216.50 04-JAN-08:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 4.22 0.00 01-JAN-11:45 1216.50 04-JAN-08:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 5.97 0.00 01-JAN-00:15 1212.08 01-SEP-13:30
EnergyTransfer:Zone:G S2 APARTMENT 10.90 0.03 17-MAY-08:45 1317.39 04-JAN-08:15
Heating:EnergyTransfer:Zone:G S2 APARTMENT 5.14 0.00 02-JAN-11:30 1317.39 04-JAN-08:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 5.76 0.00 01-JAN-00:15 1194.56 01-SEP-13:30
EnergyTransfer:Zone:M SW APARTMENT 38.88 0.08 26-APR-14:00 5156.54 30-JUN-17:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 11.46 0.00 02-JAN-11:45 4127.42 04-JAN-06:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 27.42 0.00 01-JAN-00:15 5156.54 30-JUN-17:15
EnergyTransfer:Zone:M NW APARTMENT 37.39 0.15 22-APR-13:15 4875.86 04-JAN-12:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 17.25 0.00 29-JAN-16:15 4875.86 04-JAN-12:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 20.13 0.00 01-JAN-00:15 4793.31 30-JUN-18:15
EnergyTransfer:Zone:M SE APARTMENT 38.89 0.04 22-MAR-12:30 4276.04 24-JUL-13:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 11.32 0.00 02-JAN-09:30 4104.81 04-JAN-06:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 27.58 0.00 01-JAN-00:15 4276.04 24-JUL-13:30
EnergyTransfer:Zone:M NE APARTMENT 37.51 0.02 21-OCT-14:00 4666.41 04-JAN-12:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 17.09 0.00 17-JAN-13:00 4666.41 04-JAN-12:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 20.42 0.00 01-JAN-00:15 3579.61 29-JUN-18:45
EnergyTransfer:Zone:M N1 APARTMENT 26.62 0.02 22-NOV-15:30 2996.88 30-JUN-18:45
Heating:EnergyTransfer:Zone:M N1 APARTMENT 6.04 0.00 10-JAN-18:15 2550.37 04-JAN-12:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 20.58 0.00 01-JAN-00:15 2996.88 30-JUN-18:45
EnergyTransfer:Zone:M N2 APARTMENT 26.59 0.31 21-OCT-13:00 2968.68 30-JUN-18:45
Heating:EnergyTransfer:Zone:M N2 APARTMENT 6.03 0.00 10-JAN-18:15 2544.15 04-JAN-12:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 20.56 0.00 01-JAN-00:15 2968.68 30-JUN-18:45
EnergyTransfer:Zone:M S1 APARTMENT 32.64 0.20 07-NOV-06:45 3720.80 01-SEP-15:15
Heating:EnergyTransfer:Zone:M S1 APARTMENT 2.73 0.00 01-JAN-10:00 1905.82 04-JAN-06:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 29.91 0.00 01-JAN-00:15 3720.80 01-SEP-15:15
EnergyTransfer:Zone:M S2 APARTMENT 32.64 0.01 03-MAR-05:45 3716.74 01-SEP-15:15
Heating:EnergyTransfer:Zone:M S2 APARTMENT 2.74 0.00 01-JAN-10:00 1905.28 04-JAN-06:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 29.91 0.00 01-JAN-00:15 3716.74 01-SEP-15:15
EnergyTransfer:Zone:T SW APARTMENT 29.65 0.07 01-AUG-08:45 4039.44 04-JAN-06:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 19.04 0.00 06-JAN-14:00 4039.44 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 10.61 0.00 01-JAN-00:15 3422.80 29-JUN-16:15
EnergyTransfer:Zone:T NW APARTMENT 30.70 0.03 27-SEP-06:00 4118.29 04-JAN-06:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 22.71 0.00 08-FEB-14:00 4118.29 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 7.99 0.00 01-JAN-00:15 3196.76 29-JUN-17:30
EnergyTransfer:Zone:T SE APARTMENT 29.43 0.01 14-AUG-11:00 4026.72 04-JAN-06:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 18.88 0.00 13-JAN-12:00 4026.72 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 10.55 0.00 01-JAN-00:15 2989.08 30-JUN-14:15
EnergyTransfer:Zone:T NE APARTMENT 30.59 0.04 16-APR-12:00 4105.33 04-JAN-06:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 22.55 0.00 17-MAR-15:30 4105.33 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 8.04 0.00 01-JAN-00:15 2448.96 29-JUN-16:30
EnergyTransfer:Zone:T N1 APARTMENT 22.36 0.04 11-SEP-13:00 2838.47 04-JAN-06:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 15.09 0.00 08-FEB-14:00 2838.47 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 7.28 0.00 01-JAN-00:15 2096.75 30-JUN-17:30
EnergyTransfer:Zone:T N2 APARTMENT 22.37 0.04 04-OCT-12:00 2838.38 04-JAN-06:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 15.10 0.00 08-FEB-14:00 2838.38 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 7.28 0.00 01-JAN-00:15 2075.17 30-JUN-17:30
EnergyTransfer:Zone:T S1 APARTMENT 21.74 0.47 27-OCT-06:00 2755.52 04-JAN-06:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 11.71 0.00 02-JAN-12:15 2755.52 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 10.04 0.00 01-JAN-00:15 2569.32 30-JUN-14:15
EnergyTransfer:Zone:T S2 APARTMENT 21.75 0.04 09-MAY-02:00 2755.44 04-JAN-06:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 11.71 0.00 02-JAN-11:45 2755.44 04-JAN-06:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 10.04 0.00 01-JAN-00:15 2572.81 01-SEP-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 892.92 0.00 29-APR-17:30 106822.01 04-JAN-06:00
HeatingCoils:EnergyTransfer 589.24 0.00 10-APR-15:30 106822.01 04-JAN-06:00
CoolingCoils:EnergyTransfer 303.68 0.00 01-JAN-00:15 96514.40 30-JUN-15:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 9.076 -5.916 0.000 0.000 3.889 2.413 12.213 11.163 0.000 0.050 0.000 0.000 -10.574 0.000 -6.003 -16.311
G NW APARTMENT 11.658 -4.302 0.000 0.000 3.902 2.413 12.213 5.306 0.000 0.049 0.000 0.000 -11.530 0.000 -5.935 -13.775
OFFICE 1.082 -21.101 0.000 0.000 0.544 21.914 7.534 11.190 0.000 0.038 0.000 0.000 -9.676 0.000 -4.883 -6.642
G NE APARTMENT 11.530 -4.456 0.000 0.000 3.912 2.413 12.213 5.154 0.000 0.049 0.000 0.000 -11.307 0.000 -5.924 -13.583
G N1 APARTMENT 6.378 -4.205 0.000 0.000 3.909 2.413 12.213 1.816 0.000 0.037 0.000 0.000 -7.254 0.000 -3.830 -11.476
G N2 APARTMENT 6.373 -4.204 0.000 0.000 3.909 2.413 12.213 1.816 0.000 0.037 0.000 0.000 -7.253 0.000 -3.830 -11.475
G S1 APARTMENT 4.224 -5.973 0.000 0.000 3.890 2.413 12.213 7.798 0.000 0.037 0.000 0.000 -6.386 0.000 -3.904 -14.312
G S2 APARTMENT 5.137 -5.759 0.000 0.000 3.890 2.413 12.213 7.802 0.000 0.037 0.000 0.000 -6.369 0.000 -3.904 -15.460
M SW APARTMENT 11.455 -27.420 0.000 0.000 3.806 2.413 12.213 10.786 0.000 0.068 6.470 0.000 -11.196 0.000 -8.596 -0.000
M NW APARTMENT 17.253 -20.132 0.000 0.000 3.830 2.413 12.213 5.015 0.000 0.066 0.000 0.000 -12.134 0.000 -8.515 -0.009
M SE APARTMENT 11.315 -27.576 0.000 0.000 3.810 2.413 12.213 10.676 0.000 0.068 6.688 0.000 -11.015 0.000 -8.593 -0.000
M NE APARTMENT 17.086 -20.423 0.000 0.000 3.838 2.413 12.213 4.855 0.000 0.066 0.351 0.000 -11.892 0.000 -8.506 -0.000
M N1 APARTMENT 6.036 -20.580 0.000 0.000 3.826 2.413 12.213 1.642 0.000 0.048 7.572 0.000 -7.687 0.000 -5.483 -0.001
M N2 APARTMENT 6.031 -20.560 0.000 0.000 3.827 2.413 12.213 1.642 0.000 0.048 7.554 0.000 -7.686 0.000 -5.482 -0.000
M S1 APARTMENT 2.728 -29.907 0.000 0.000 3.792 2.413 12.213 7.557 0.000 0.051 13.506 0.000 -6.791 0.000 -5.562 -0.000
M S2 APARTMENT 2.736 -29.905 0.000 0.000 3.793 2.413 12.213 7.556 0.000 0.051 13.496 0.000 -6.790 0.000 -5.562 -0.000
T SW APARTMENT 19.036 -10.612 0.000 0.000 3.859 2.413 12.213 10.748 0.000 0.094 0.000 0.000 -10.713 0.000 -11.106 -15.933
T NW APARTMENT 22.714 -7.986 0.000 0.000 3.878 2.413 12.213 4.999 0.000 0.091 0.000 0.000 -11.648 0.000 -11.001 -15.673
T SE APARTMENT 18.876 -10.549 0.000 0.000 3.863 2.413 12.213 10.659 0.000 0.094 0.000 0.000 -10.553 0.000 -11.107 -15.909
T NE APARTMENT 22.551 -8.039 0.000 0.000 3.888 2.413 12.213 4.862 0.000 0.091 0.000 0.000 -11.425 0.000 -10.995 -15.559
T N1 APARTMENT 15.090 -7.275 0.000 0.000 3.880 2.413 12.213 1.657 0.000 0.068 0.000 0.000 -7.340 0.000 -7.010 -13.695
T N2 APARTMENT 15.096 -7.278 0.000 0.000 3.881 2.413 12.213 1.656 0.000 0.068 0.000 0.000 -7.338 0.000 -7.010 -13.700
T S1 APARTMENT 11.707 -10.036 0.000 0.000 3.852 2.413 12.213 7.548 0.000 0.071 0.000 0.000 -6.494 0.000 -7.116 -14.158
T S2 APARTMENT 11.709 -10.041 0.000 0.000 3.852 2.413 12.213 7.546 0.000 0.071 0.000 0.000 -6.493 0.000 -7.116 -14.153
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.054 0.000 0.002 0.000 0.000 -1.346 0.000 -1.769 -14.011
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.211 0.000 0.110 12.141 0.000 -3.634 0.000 -32.164 -0.000
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.053 0.000 0.002 0.000 0.000 -1.468 0.000 -1.449 -14.209
Total Facility 266.877 -324.237 0.000 0.000 89.322 128.627 294.692 151.768 0.000 1.565 67.778 0.000 -223.995 0.000 -202.355 -250.045


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 01-SEP-15:30 0.00 -1759.27 0.00 0.00 48.90 100.83 470.90 2702.93 0.00 45.84 0.00 0.00 0.00 0.00 0.00 -1610.12
G NW APARTMENT 29-JUN-17:15 0.00 -1621.21 0.00 0.00 141.82 194.45 588.62 1927.87 0.00 85.82 0.00 0.00 0.00 0.00 0.00 -1317.37
OFFICE 24-JUL-13:30 0.00 -3142.63 0.00 0.00 67.31 1622.34 544.92 1848.16 0.00 49.54 0.00 0.00 0.00 0.00 0.00 -989.64
G NE APARTMENT 29-JUN-19:00 0.00 -1116.81 0.00 0.00 140.88 230.46 547.42 459.04 0.00 83.06 0.00 0.00 0.00 0.00 0.00 -344.05
G N1 APARTMENT 29-JUN-19:00 0.00 -932.84 0.00 0.00 140.89 230.46 547.42 362.95 0.00 50.04 0.00 0.00 0.00 0.00 0.00 -398.92
G N2 APARTMENT 29-JUN-19:00 0.00 -920.64 0.00 0.00 140.84 230.46 547.42 363.10 0.00 49.98 0.00 0.00 0.00 0.00 0.00 -411.16
G S1 APARTMENT 01-SEP-13:30 0.00 -1211.90 0.00 0.00 40.75 28.81 382.60 2035.87 0.00 13.69 0.00 0.00 0.00 0.00 0.00 -1289.83
G S2 APARTMENT 06-JAN-12:34 0.00 -1233.57 0.00 0.00 47.42 28.81 406.15 1880.48 0.00 0.00 0.00 0.00 0.00 0.00 -147.19 -982.10
M SW APARTMENT 30-JUN-17:10 0.00 -5157.56 0.00 0.00 141.82 194.45 588.62 1853.43 0.00 112.37 2266.86 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 30-JUN-18:15 0.00 -4791.89 0.00 0.00 141.82 230.46 547.42 1848.35 0.00 79.10 1944.74 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 24-JUL-13:30 0.00 -4275.91 0.00 0.00 40.75 28.81 382.60 1820.02 0.00 64.15 1939.58 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 29-JUN-18:45 0.00 -3579.50 0.00 0.00 141.08 230.46 547.42 560.03 0.00 123.58 1976.92 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 30-JUN-18:45 0.00 -2996.01 0.00 0.00 141.82 230.46 547.42 549.22 0.00 33.67 1493.43 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 30-JUN-18:45 0.00 -2967.83 0.00 0.00 141.82 230.46 547.42 549.39 0.00 33.67 1465.06 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 01-SEP-15:15 0.00 -3720.46 0.00 0.00 48.90 100.83 470.90 1275.59 0.00 54.03 1770.21 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 01-SEP-15:15 0.00 -3716.40 0.00 0.00 48.90 100.83 470.90 1275.59 0.00 54.03 1766.15 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 29-JUN-16:05 0.00 -3425.57 0.00 0.00 84.77 144.04 588.62 2045.72 0.00 237.01 325.41 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 29-JUN-17:15 0.00 -3201.07 0.00 0.00 141.43 194.45 588.62 1877.64 0.00 161.43 237.50 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 30-JUN-14:15 0.00 -2989.15 0.00 0.00 40.75 50.41 400.26 1479.32 0.00 186.51 831.89 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 29-JUN-16:30 0.00 -2450.51 0.00 0.00 84.27 144.04 588.62 649.36 0.00 207.79 776.43 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 30-JUN-17:23 0.00 -2102.13 0.00 0.00 141.48 194.45 588.62 343.86 0.00 83.07 750.65 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 30-JUN-17:23 0.00 -2075.45 0.00 0.00 141.33 194.45 588.62 343.98 0.00 82.86 724.20 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 30-JUN-14:15 0.00 -2569.29 0.00 0.00 40.75 50.41 400.26 1178.38 0.00 112.49 786.99 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 01-SEP-13:30 0.00 -2572.55 0.00 0.00 40.75 28.81 382.60 1996.45 0.00 21.89 102.05 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-JUN-17:10 0.00 -58627.28 0.00 0.00 3260.21 6475.86 14071.03 17982.19 0.00 2353.80 14484.18 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 04-JAN-08:15 2012.84 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -970.21 0.00 -734.28 -814.02
G NW APARTMENT 04-JAN-12:00 2275.00 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -869.48 0.00 -1107.36 -786.42
OFFICE 20-NOV-07:01 6487.50 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -417.34 0.00 -204.39 -6440.34
G NE APARTMENT 04-JAN-12:00 2180.52 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -817.77 0.00 -1107.36 -743.65
G N1 APARTMENT 04-JAN-12:00 1383.69 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -528.29 0.00 -667.93 -675.73
G N2 APARTMENT 04-JAN-12:00 1380.21 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -528.35 0.00 -667.93 -672.19
G S1 APARTMENT 02-DEC-18:13 1817.40 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -604.83 0.00 -7.99 -2152.66
G S2 APARTMENT 06-JAN-12:38 1680.09 0.00 0.00 0.00 47.42 28.81 406.15 1880.48 0.00 0.00 0.00 0.00 0.00 0.00 -148.44 -3894.50
M SW APARTMENT 04-JAN-06:00 4127.38 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1244.73 0.00 -1316.01 -2103.04
M NW APARTMENT 04-JAN-12:00 4875.79 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -901.79 0.00 -1592.01 -2870.25
M SE APARTMENT 04-JAN-06:00 4104.76 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1224.95 0.00 -1316.01 -2100.20
M NE APARTMENT 04-JAN-12:00 4666.35 0.00 0.00 0.00 47.42 28.81 412.04 0.00 0.00 0.00 0.00 0.00 -847.85 0.00 -1592.01 -2714.75
M N1 APARTMENT 12-MAR-06:30 2903.47 0.00 0.00 0.00 161.22 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -645.47 0.00 0.00 -2895.45
M N2 APARTMENT 12-MAR-06:23 2901.75 0.00 0.00 0.00 161.22 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -645.42 0.00 0.00 -2893.78
M S1 APARTMENT 05-MAR-08:30 3066.98 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -208.37 0.00 0.00 -3364.28
M S2 APARTMENT 15-FEB-01:53 3043.46 0.00 0.00 0.00 189.67 14.40 241.34 0.00 0.00 0.00 0.00 0.00 -640.14 0.00 0.00 -2848.74
T SW APARTMENT 04-JAN-06:00 4039.39 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1216.40 0.00 -1742.07 -1617.33
T NW APARTMENT 04-JAN-06:00 4118.24 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1243.51 0.00 -1742.07 -1669.06
T SE APARTMENT 04-JAN-06:00 4026.67 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1195.66 0.00 -1742.07 -1625.34
T NE APARTMENT 04-JAN-06:00 4105.28 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -1222.82 0.00 -1742.07 -1676.79
T N1 APARTMENT 04-JAN-06:00 2838.44 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -754.28 0.00 -1050.81 -1569.75
T N2 APARTMENT 04-JAN-06:00 2838.35 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -754.28 0.00 -1050.81 -1569.66
T S1 APARTMENT 04-JAN-06:00 2755.50 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -726.92 0.00 -1050.81 -1514.17
T S2 APARTMENT 04-JAN-06:00 2755.42 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -726.92 0.00 -1050.81 -1514.09
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 04-JAN-06:00 64173.23 0.00 0.00 0.00 4362.43 4156.84 6111.77 0.00 0.00 0.00 0.00 0.00 -24167.40 0.00 -26039.00 -28597.87



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sec1.1A-General Information

Data
Weather File International Falls Intl Ap MN USA TMY3 WMO#=727470
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 33.00
Number of hours cooling loads not met 4.75
Number of hours not met 37.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 8572.78 0.00 0.00 0.00 0.00
Exterior Lighting 39.38 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 736.55 133527.51 0.00 0.00
Space Cooling 74.23 23830.29 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 207.67 6585.31 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 467.85 26850.23 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 26456.41 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1465.55   736.55   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1465.55
Natural Gas 0.00 736.55
Additional 0.00 0.00
Total 511.42 2202.10


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 23.68
Fans-Interior 66.25
Service Water Heating 149.25
Receptacle Equipment 163.15
Miscellaneous 12.56
Subtotal 467.54


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 234.97
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 234.97


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.49
Space Heating 33.45
Space Cooling 3.37
Fans-Interior 9.43
Service Water Heating 21.25
Receptacle Equipment 23.22
Miscellaneous 1.79



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.158556
G NW APARTMENT DIRECT AIR 0.146306
OFFICE DIRECT AIR 0.438934
G NE APARTMENT DIRECT AIR 0.102043
G N1 APARTMENT DIRECT AIR 0.087273
G N2 APARTMENT DIRECT AIR 0.086178
G S1 APARTMENT DIRECT AIR 0.104409
G S2 APARTMENT DIRECT AIR 0.107711
M SW APARTMENT DIRECT AIR 0.457908
M NW APARTMENT DIRECT AIR 0.417648
M SE APARTMENT DIRECT AIR 0.411198
M NE APARTMENT DIRECT AIR 0.316052
M N1 APARTMENT DIRECT AIR 0.264274
M N2 APARTMENT DIRECT AIR 0.262342
M S1 APARTMENT DIRECT AIR 0.319245
M S2 APARTMENT DIRECT AIR 0.320546
T SW APARTMENT DIRECT AIR 0.302474
T NW APARTMENT DIRECT AIR 0.269657
T SE APARTMENT DIRECT AIR 0.283148
T NE APARTMENT DIRECT AIR 0.208122
T N1 APARTMENT DIRECT AIR 0.170408
T N2 APARTMENT DIRECT AIR 0.168217
T S1 APARTMENT DIRECT AIR 0.237801
T S2 APARTMENT DIRECT AIR 0.238728


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.158556
SPLIT GNW MAIN BRANCH 0.146306
SPLIT OFFICE MAIN BRANCH 0.438934
SPLIT GNE MAIN BRANCH 0.102043
SPLIT GN1 MAIN BRANCH 0.087273
SPLIT GN2 MAIN BRANCH 0.086178
SPLIT GS1 MAIN BRANCH 0.104409
SPLIT GS2 MAIN BRANCH 0.107711
SPLIT MSW MAIN BRANCH 0.457908
SPLIT MNW MAIN BRANCH 0.417648
SPLIT MSE MAIN BRANCH 0.411198
SPLIT MNE MAIN BRANCH 0.316052
SPLIT MN1 MAIN BRANCH 0.264274
SPLIT MN2 MAIN BRANCH 0.262342
SPLIT MS1 MAIN BRANCH 0.319245
SPLIT MS2 MAIN BRANCH 0.320546
SPLIT TSW MAIN BRANCH 0.302474
SPLIT TNW MAIN BRANCH 0.269657
SPLIT TSE MAIN BRANCH 0.283148
SPLIT TNE MAIN BRANCH 0.208122
SPLIT TN1 MAIN BRANCH 0.170408
SPLIT TN2 MAIN BRANCH 0.168217
SPLIT TS1 MAIN BRANCH 0.237801
SPLIT TS2 MAIN BRANCH 0.238728


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.158556
SPLIT GNW 0.146306
SPLIT OFFICE 0.438934
SPLIT GNE 0.102043
SPLIT GN1 0.087273
SPLIT GN2 0.086178
SPLIT GS1 0.104409
SPLIT GS2 0.107711
SPLIT MSW 0.457908
SPLIT MNW 0.417648
SPLIT MSE 0.411198
SPLIT MNE 0.316052
SPLIT MN1 0.264274
SPLIT MN2 0.262342
SPLIT MS1 0.319245
SPLIT MS2 0.320546
SPLIT TSW 0.302474
SPLIT TNW 0.269657
SPLIT TSE 0.283148
SPLIT TNE 0.208122
SPLIT TN1 0.170408
SPLIT TN2 0.168217
SPLIT TS1 0.237801
SPLIT TS2 0.238728


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.158556 0.026898
SPLIT GNW OA CONTROLLER 0.146306 0.025953
SPLIT OFFICE OA CONTROLLER 0.438934 0.038104
SPLIT GNE OA CONTROLLER 0.102043 0.025953
SPLIT GN1 OA CONTROLLER 0.087273 0.025953
SPLIT GN2 OA CONTROLLER 0.086178 0.025953
SPLIT GS1 OA CONTROLLER 0.104409 0.025953
SPLIT GS2 OA CONTROLLER 0.107711 0.025953
SPLIT MSW OA CONTROLLER 0.457908 0.051906
SPLIT MNW OA CONTROLLER 0.417648 0.051906
SPLIT MSE OA CONTROLLER 0.411198 0.051906
SPLIT MNE OA CONTROLLER 0.316052 0.051906
SPLIT MN1 OA CONTROLLER 0.264274 0.051906
SPLIT MN2 OA CONTROLLER 0.262342 0.051906
SPLIT MS1 OA CONTROLLER 0.319245 0.051906
SPLIT MS2 OA CONTROLLER 0.320546 0.051906
SPLIT TSW OA CONTROLLER 0.302474 0.025953
SPLIT TNW OA CONTROLLER 0.269657 0.025953
SPLIT TSE OA CONTROLLER 0.283148 0.025953
SPLIT TNE OA CONTROLLER 0.208122 0.025953
SPLIT TN1 OA CONTROLLER 0.170408 0.025953
SPLIT TN2 OA CONTROLLER 0.168217 0.025953
SPLIT TS1 OA CONTROLLER 0.237801 0.025953
SPLIT TS2 OA CONTROLLER 0.238728 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.158556 2852.73 0.769261
SPLIT GNW COOLING COIL 0.146306 2631.97 0.769307
SPLIT OFFICE COOLING COIL 0.438934 7265.92 0.798655
SPLIT GNE COOLING COIL 0.102043 1938.11 0.751433
SPLIT GN1 COOLING COIL 0.087273 1680.49 0.747065
SPLIT GN2 COOLING COIL 0.086178 1663.67 0.746254
SPLIT GS1 COOLING COIL 0.104409 2089.71 0.735078
SPLIT GS2 COOLING COIL 0.107711 2134.84 0.738061
SPLIT MSW COOLING COIL 0.457908 7862.37 0.785451
SPLIT MNW COOLING COIL 0.417648 7204.60 0.783803
SPLIT MSE COOLING COIL 0.411198 7391.42 0.769575
SPLIT MNE COOLING COIL 0.316052 5629.85 0.772659
SPLIT MN1 COOLING COIL 0.264274 4746.07 0.769885
SPLIT MN2 COOLING COIL 0.262342 4717.02 0.769478
SPLIT MS1 COOLING COIL 0.319245 5921.50 0.759113
SPLIT MS2 COOLING COIL 0.320546 5928.24 0.760077
SPLIT TSW COOLING COIL 0.302474 5190.96 0.785628
SPLIT TNW COOLING COIL 0.269657 4580.55 0.789283
SPLIT TSE COOLING COIL 0.283148 4923.47 0.781005
SPLIT TNE COOLING COIL 0.208122 3789.52 0.765245
SPLIT TN1 COOLING COIL 0.170408 3001.73 0.776501
SPLIT TN2 COOLING COIL 0.168217 2968.82 0.775840
SPLIT TS1 COOLING COIL 0.237801 4174.64 0.777678
SPLIT TS2 COOLING COIL 0.238728 4188.61 0.777869


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.158556 0.158556 0.158556 0.158556 4027.69 2852.73 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.146306 0.146306 0.146306 0.146306 3954.03 2631.97 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.438934 0.438934 0.438934 0.438934 7039.97 7265.92 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.102043 0.102043 0.102043 0.102043 3942.11 1938.11 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.087273 0.087273 0.087273 0.087273 3126.02 1680.49 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.086178 0.086178 0.086178 0.086178 3125.76 1663.67 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.104409 0.104409 0.104409 0.104409 3143.66 2089.71 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.107711 0.107711 0.107711 0.107711 3280.44 2134.84 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.457908 0.457908 0.457908 0.457908 7524.13 7862.37 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.417648 0.417648 0.417648 0.417648 7481.90 7204.60 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.411198 0.411198 0.411198 0.411198 7492.93 7391.42 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.316052 0.316052 0.316052 0.316052 7450.66 5629.85 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.264274 0.264274 0.264274 0.264274 5459.39 4746.07 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.262342 0.262342 0.262342 0.262342 5458.65 4717.02 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.319245 0.319245 0.319245 0.319245 5504.87 5921.50 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.320546 0.320546 0.320546 0.320546 5504.14 5928.24 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.302474 0.302474 0.302474 0.302474 5731.77 5190.96 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.269657 0.269657 0.269657 0.269657 5711.44 4580.55 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.283148 0.283148 0.283148 0.283148 5715.06 4923.47 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.208122 0.208122 0.208122 0.208122 5694.71 3789.52 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.170408 0.170408 0.170408 0.170408 4647.24 3001.73 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.168217 0.168217 0.168217 0.168217 4646.83 2968.82 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.237801 0.237801 0.237801 0.237801 4666.35 4174.64 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.238728 0.238728 0.238728 0.238728 4665.94 4188.61 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.158556
SPLIT GNW SUPPLY FAN 0.146306
SPLIT OFFICE SUPPLY FAN 0.438934
SPLIT GNE SUPPLY FAN 0.102043
SPLIT GN1 SUPPLY FAN 0.087273
SPLIT GN2 SUPPLY FAN 0.086178
SPLIT GS1 SUPPLY FAN 0.104409
SPLIT GS2 SUPPLY FAN 0.107711
SPLIT MSW SUPPLY FAN 0.457908
SPLIT MNW SUPPLY FAN 0.417648
SPLIT MSE SUPPLY FAN 0.411198
SPLIT MNE SUPPLY FAN 0.316052
SPLIT MN1 SUPPLY FAN 0.264274
SPLIT MN2 SUPPLY FAN 0.262342
SPLIT MS1 SUPPLY FAN 0.319245
SPLIT MS2 SUPPLY FAN 0.320546
SPLIT TSW SUPPLY FAN 0.302474
SPLIT TNW SUPPLY FAN 0.269657
SPLIT TSE SUPPLY FAN 0.283148
SPLIT TNE SUPPLY FAN 0.208122
SPLIT TN1 SUPPLY FAN 0.170408
SPLIT TN2 SUPPLY FAN 0.168217
SPLIT TS1 SUPPLY FAN 0.237801
SPLIT TS2 SUPPLY FAN 0.238728


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 4027.69
SPLIT GNW HEATING COIL 3954.03
SPLIT OFFICE HEATING COIL 7039.97
SPLIT GNE HEATING COIL 3942.11
SPLIT GN1 HEATING COIL 3126.02
SPLIT GN2 HEATING COIL 3125.76
SPLIT GS1 HEATING COIL 3143.66
SPLIT GS2 HEATING COIL 3280.44
SPLIT MSW HEATING COIL 7524.13
SPLIT MNW HEATING COIL 7481.90
SPLIT MSE HEATING COIL 7492.93
SPLIT MNE HEATING COIL 7450.66
SPLIT MN1 HEATING COIL 5459.39
SPLIT MN2 HEATING COIL 5458.65
SPLIT MS1 HEATING COIL 5504.87
SPLIT MS2 HEATING COIL 5504.14
SPLIT TSW HEATING COIL 5731.77
SPLIT TNW HEATING COIL 5711.44
SPLIT TSE HEATING COIL 5715.06
SPLIT TNE HEATING COIL 5694.71
SPLIT TN1 HEATING COIL 4647.24
SPLIT TN2 HEATING COIL 4646.83
SPLIT TS1 HEATING COIL 4666.35
SPLIT TS2 HEATING COIL 4665.94



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.71 -11.6
March 21.75 -6.2
April 22.07 3.97
May 23.04 13.43
June 24.10 18.03
July 24.34 19.67
August 24.29 17.94
September 23.74 12.29
October 22.10 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.69 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.34 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.71 -6.2
April 21.86 3.97
May 22.86 13.43
June 24.09 18.03
July 24.33 19.67
August 24.25 17.94
September 23.53 12.29
October 21.86 5.42
November 21.71 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.61 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.33 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 17.68 -16.9
February 18.30 -11.6
March 19.52 -6.2
April 21.52 3.97
May 23.26 13.43
June 23.86 18.03
July 23.90 19.67
August 23.89 17.94
September 23.73 12.29
October 22.03 5.42
November 19.91 -2.0
December 17.72 -14.6
     
Annual Sum or Average 21.29 3.36
Minimum of Months 17.68 -16.9
Maximum of Months 23.90 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.70 -6.2
April 21.81 3.97
May 22.76 13.43
June 24.07 18.03
July 24.31 19.67
August 24.21 17.94
September 23.44 12.29
October 21.82 5.42
November 21.71 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.58 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.31 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.70 -6.2
April 21.78 3.97
May 22.65 13.43
June 24.05 18.03
July 24.31 19.67
August 24.24 17.94
September 23.56 12.29
October 21.83 5.42
November 21.71 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.58 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.31 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.70 -6.2
April 21.78 3.97
May 22.64 13.43
June 24.05 18.03
July 24.31 19.67
August 24.23 17.94
September 23.56 12.29
October 21.83 5.42
November 21.71 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.58 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.31 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.71 -11.6
March 21.73 -6.2
April 22.00 3.97
May 22.91 13.43
June 24.10 18.03
July 24.33 19.67
August 24.30 17.94
September 23.85 12.29
October 22.13 5.42
November 21.73 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.69 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.33 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.71 -11.6
March 21.73 -6.2
April 22.00 3.97
May 22.91 13.43
June 24.10 18.03
July 24.33 19.67
August 24.29 17.94
September 23.85 12.29
October 22.14 5.42
November 21.73 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.69 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.33 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.80 -11.6
March 22.00 -6.2
April 22.95 3.97
May 24.26 13.43
June 24.39 18.03
July 24.40 19.67
August 24.40 17.94
September 24.29 12.29
October 23.02 5.42
November 21.83 -2.0
December 21.70 -14.6
     
Annual Sum or Average 23.07 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.75 -6.2
April 22.50 3.97
May 24.18 13.43
June 24.39 18.03
July 24.40 19.67
August 24.39 17.94
September 24.19 12.29
October 22.59 5.42
November 21.73 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.94 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.78 -11.6
March 21.97 -6.2
April 22.97 3.97
May 24.26 13.43
June 24.39 18.03
July 24.40 19.67
August 24.40 17.94
September 24.27 12.29
October 22.96 5.42
November 21.81 -2.0
December 21.70 -14.6
     
Annual Sum or Average 23.06 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.72 -6.2
April 22.45 3.97
May 24.15 13.43
June 24.39 18.03
July 24.40 19.67
August 24.39 17.94
September 24.13 12.29
October 22.44 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.91 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.73 -6.2
April 22.48 3.97
May 24.19 13.43
June 24.40 18.03
July 24.40 19.67
August 24.40 17.94
September 24.27 12.29
October 22.73 5.42
November 21.75 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.96 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.73 -6.2
April 22.47 3.97
May 24.19 13.43
June 24.40 18.03
July 24.40 19.67
August 24.40 17.94
September 24.27 12.29
October 22.71 5.42
November 21.75 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.96 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.85 -11.6
March 22.08 -6.2
April 23.13 3.97
May 24.30 13.43
June 24.40 18.03
July 24.40 19.67
August 24.40 17.94
September 24.35 12.29
October 23.28 5.42
November 21.95 -2.0
December 21.70 -14.6
     
Annual Sum or Average 23.14 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.85 -11.6
March 22.08 -6.2
April 23.13 3.97
May 24.30 13.43
June 24.40 18.03
July 24.40 19.67
August 24.40 17.94
September 24.35 12.29
October 23.28 5.42
November 21.95 -2.0
December 21.70 -14.6
     
Annual Sum or Average 23.14 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.40 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.78 -11.6
March 21.94 -6.2
April 22.52 3.97
May 23.78 13.43
June 24.24 18.03
July 24.36 19.67
August 24.31 17.94
September 23.58 12.29
October 22.33 5.42
November 21.78 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.84 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.36 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.75 -6.2
April 22.25 3.97
May 23.67 13.43
June 24.22 18.03
July 24.35 19.67
August 24.28 17.94
September 23.34 12.29
October 22.04 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.73 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.35 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.76 -11.6
March 21.93 -6.2
April 22.54 3.97
May 23.79 13.43
June 24.24 18.03
July 24.35 19.67
August 24.30 17.94
September 23.57 12.29
October 22.30 5.42
November 21.77 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.84 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.35 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.71 -6.2
April 22.21 3.97
May 23.65 13.43
June 24.19 18.03
July 24.32 19.67
August 24.24 17.94
September 23.28 12.29
October 21.98 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.71 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.32 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.72 -6.2
April 22.18 3.97
May 23.67 13.43
June 24.23 18.03
July 24.34 19.67
August 24.29 17.94
September 23.35 12.29
October 22.00 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.72 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.34 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.70 -11.6
March 21.71 -6.2
April 22.17 3.97
May 23.66 13.43
June 24.23 18.03
July 24.34 19.67
August 24.28 17.94
September 23.34 12.29
October 22.00 5.42
November 21.72 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.72 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.34 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.80 -11.6
March 21.95 -6.2
April 22.57 3.97
May 23.85 13.43
June 24.28 18.03
July 24.37 19.67
August 24.34 17.94
September 23.70 12.29
October 22.41 5.42
November 21.80 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.88 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.37 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -16.9
February 21.80 -11.6
March 21.96 -6.2
April 22.58 3.97
May 23.85 13.43
June 24.28 18.03
July 24.37 19.67
August 24.34 17.94
September 23.70 12.29
October 22.41 5.42
November 21.80 -2.0
December 21.70 -14.6
     
Annual Sum or Average 22.88 3.36
Minimum of Months 21.70 -16.9
Maximum of Months 24.37 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.77 -16.9
February 20.41 -11.6
March 21.22 -6.2
April 22.86 3.97
May 25.35 13.43
June 26.29 18.03
July 26.59 19.67
August 26.28 17.94
September 24.84 12.29
October 22.64 5.42
November 21.19 -2.0
December 19.90 -14.6
     
Annual Sum or Average 23.13 3.36
Minimum of Months 19.77 -16.9
Maximum of Months 26.59 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 17.23 -16.9
February 18.12 -11.6
March 19.00 -6.2
April 20.85 3.97
May 23.00 13.43
June 25.11 18.03
July 25.75 19.67
August 25.39 17.94
September 24.21 12.29
October 21.33 5.42
November 19.65 -2.0
December 17.56 -14.6
     
Annual Sum or Average 21.45 3.36
Minimum of Months 17.23 -16.9
Maximum of Months 25.75 19.67



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.51 -16.9
February 22.89 -11.6
March 23.35 -6.2
April 24.66 3.97
May 26.50 13.43
June 26.86 18.03
July 26.97 19.67
August 26.83 17.94
September 26.44 12.29
October 24.78 5.42
November 23.20 -2.0
December 22.50 -14.6
     
Annual Sum or Average 24.80 3.36
Minimum of Months 22.50 -16.9
Maximum of Months 26.97 19.67



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.122394E+12 76727.272 30-JAN-18:30 8572.775 26456.413 6585.311 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32604.443 0.000 0.000 0.000
February 0.111012E+12 76756.338 22-FEB-18:15 8572.775 26456.413 6585.311 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32633.508 0.000 0.000 0.000
March 0.122355E+12 74361.259 10-MAR-18:15 8572.775 26456.413 6585.311 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 30238.430 0.000 0.000 0.000
April 0.117992E+12 80407.923 23-APR-17:00 8572.775 26456.413 6585.311 0.000 11346.161 0.000 0.000 0.000 0.000 0.000 0.000 27447.263 0.000 0.000 0.000
May 0.126929E+12 86198.550 25-MAY-17:15 8572.775 26456.413 6585.311 0.000 16497.521 0.000 0.000 0.000 0.000 0.000 0.000 28086.530 0.000 0.000 0.000
June 0.128884E+12 92295.013 29-JUN-17:30 8572.775 26456.413 6585.311 0.000 23830.286 0.000 0.000 0.000 0.000 0.000 0.000 26850.228 0.000 0.000 0.000
July 0.136455E+12 88453.870 23-JUL-17:00 8572.775 26456.413 6585.311 0.000 18838.035 0.000 0.000 0.000 0.000 0.000 0.000 28001.336 0.000 0.000 0.000
August 0.130396E+12 86151.183 08-AUG-17:30 8572.775 26456.413 6585.311 0.000 19898.595 0.000 0.000 0.000 0.000 0.000 0.000 24638.088 0.000 0.000 0.000
September 0.116617E+12 80401.509 01-SEP-17:15 8572.775 26456.413 6585.311 0.000 14643.259 0.000 0.000 0.000 0.000 0.000 0.000 24143.751 0.000 0.000 0.000
October 0.117228E+12 74458.589 22-OCT-17:30 8572.775 26456.413 6585.311 0.000 4625.447 2508.330 0.000 0.000 0.000 0.000 0.000 25710.313 0.000 0.000 0.000
November 0.114571E+12 72485.852 01-NOV-17:45 8572.775 26456.413 6585.311 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 28363.023 0.000 0.000 0.000
December 0.120719E+12 75422.790 22-DEC-18:45 8572.775 26456.413 6585.311 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 31299.961 0.000 0.000 0.000
                                     
Annual Sum or Average 0.146555E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.111012E+12 72485.852   8572.775 26456.413 6585.311 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 24143.751 0.000 0.000 0.000
Maximum of Months 0.136455E+12 92295.013   8572.775 26456.413 6585.311 0.000 23830.286 2508.330 0.000 0.000 0.000 0.000 0.000 32633.508 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.191158E+12 133527.510 04-JAN-05:00 133527.510 0.000 0.000 0.000 0.000 0.000 133527.510
February 0.132026E+12 116677.276 14-FEB-04:00 116677.276 0.000 0.000 0.000 0.000 0.000 116677.276
March 0.943608E+11 100106.050 05-MAR-03:00 100106.050 0.000 0.000 0.000 0.000 0.000 100106.050
April 0.313906E+11 56785.019 05-APR-02:00 56785.019 0.000 0.000 0.000 0.000 0.000 56785.019
May 0.233321E+10 19050.587 01-MAY-03:00 19050.587 0.000 0.000 0.000 0.000 0.000 19050.587
June 0.138979E+08 1362.354 04-JUN-03:00 1362.354 0.000 0.000 0.000 0.000 0.000 1362.354
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 4049511.300 844.125 19-AUG-05:30 844.125 0.000 0.000 0.000 0.000 0.000 844.125
September 0.718084E+09 4576.159 28-SEP-01:00 4576.159 0.000 0.000 0.000 0.000 0.000 4576.159
October 0.222759E+11 50222.593 30-OCT-06:00 50222.593 0.000 0.000 0.000 0.000 0.000 50222.593
November 0.810623E+11 86906.201 25-NOV-04:00 86906.201 0.000 0.000 0.000 0.000 0.000 86906.201
December 0.181204E+12 129961.276 24-DEC-07:00 129961.276 0.000 0.000 0.000 0.000 0.000 129961.276
                     
Annual Sum or Average 0.736548E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.191158E+12 133527.510   133527.510 0.000 0.000 0.000 0.000 0.000 133527.510