Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
Simulation Timestamp: 2018-10-19 09:20:31
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1546.64 | 493.41 | 547.68 |
Net Site Energy | 1546.64 | 493.41 | 547.68 |
Total Source Energy | 4592.08 | 1464.96 | 1626.10 |
Net Source Energy | 4592.08 | 1464.96 | 1626.10 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 146.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 66.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 211.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 405.21 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1399.68 | 146.96 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 146.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 66.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 211.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 405.21 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 242.17 | 52.04 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 495.64 | 52.04 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 218.17 | 46.88 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.52 | 46.88 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1399.68 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1399.68 | 100.00 |
Total On-Site and Utility Electric Sources | 1399.68 | 100.00 |
Total Electricity End Uses | 1399.68 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 86.25 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 544.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930 |
Weather File | Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930 |
Latitude [deg] | 47.47 |
Longitude [deg] | -122.3 |
Elevation [m] | 122.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 10-AUG-17:30 | 19-FEB-05:00 | - | - | - | 01-JAN-07:30 |
Heating | 0.00 | 52217.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 18773.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6720.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 22922.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 83445.56 | 52217.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 52217.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 18773.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6720.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 22922.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 159.30 | 0.00 | 0.00 | 0.00 |
Cooling | 211.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 671.21 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1283.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4432.77 | 159.30 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 56.41 | 0.00 | 0.00 | 0.00 |
Cooling | 74.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 237.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 454.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1569.69 | 56.41 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 56.41 | 0.00 | 0.00 | 0.00 |
Cooling | 74.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 237.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 454.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1569.69 | 56.41 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | -4.20 | 0.00 | -4.20 | Wetbulb [C] | 4.30 | 20.00 |
SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 29.40 | 10.40 | 18.30 | Wetbulb [C] | 4.20 | 350.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.52_SHGC_0.40 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.60 | 83.60 | 39.36 | |
Exterior Lighting Total | 2508.33 | 39.36 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2933.70 | 2343.01 | 590.68 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2343.80 | 1871.89 | 471.91 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7400.08 | 5910.11 | 1489.97 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1591.15 | 1270.78 | 320.37 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1310.18 | 1046.38 | 263.80 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1291.91 | 1031.79 | 260.12 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2199.69 | 1741.72 | 457.97 | 0.79 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2242.82 | 1779.51 | 463.31 | 0.79 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8135.17 | 6497.20 | 1637.97 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6474.61 | 5170.98 | 1303.63 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7554.64 | 6033.55 | 1521.09 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4829.24 | 3856.90 | 972.34 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3836.37 | 3063.94 | 772.43 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3803.61 | 3037.77 | 765.84 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6134.31 | 4899.20 | 1235.11 | 0.80 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6155.14 | 4915.84 | 1239.31 | 0.80 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5339.45 | 4264.38 | 1075.07 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4149.30 | 3313.86 | 835.44 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5005.58 | 3997.73 | 1007.85 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3101.11 | 2476.72 | 624.39 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2480.99 | 1975.38 | 505.62 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2482.64 | 1974.08 | 508.55 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4311.50 | 3443.40 | 868.10 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4325.15 | 3454.30 | 870.85 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2794.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2232.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7049.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1515.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1248.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1230.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2097.5 | 3.14 | 10.71 | 11.13 | 10.44 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2138.1 | 3.14 | 10.70 | 11.12 | 10.42 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7750.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6168.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7197.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4600.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3654.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3623.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5843.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5863.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5086.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3952.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4768.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2954.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2364.3 | 3.13 | 10.69 | 11.10 | 10.40 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2366.2 | 3.13 | 10.69 | 11.11 | 10.41 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4107.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4120.4 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1948.11 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1926.74 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 3758.68 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1931.71 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1677.79 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1677.79 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1677.79 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1677.79 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 3796.14 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 3819.21 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 3809.50 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 3832.56 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 3355.59 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 3355.59 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 3355.59 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 3355.59 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 2977.80 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 2991.27 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 2984.71 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 2998.18 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 2317.43 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 2317.63 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 2301.88 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 2302.08 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.18 | 198.51 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 158.59 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 500.73 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 107.67 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 88.65 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 87.42 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 146.07 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 149.60 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.49 | 550.47 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 438.11 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.46 | 511.19 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 326.77 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 259.59 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 257.37 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 415.08 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 416.49 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 361.30 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 280.77 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 338.71 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 209.84 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 166.76 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 166.39 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 291.74 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 292.66 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1859.05 | 2230.86 | 0.148 | 0.177 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 16:15:00 | 28.57 | 0.00879 |
G NW APARTMENT | 1485.25 | 1782.30 | 0.118 | 0.142 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 26.90 | 0.00879 |
OFFICE | 4595.79 | 5514.95 | 0.373 | 0.447 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.68 | 0.00879 |
G NE APARTMENT | 1008.26 | 1209.91 | 0.080 | 0.096 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 09:45:00 | 25.01 | 0.00879 |
G N1 APARTMENT | 830.25 | 996.30 | 0.066 | 0.079 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 25.34 | 0.00879 |
G N2 APARTMENT | 818.67 | 982.41 | 0.065 | 0.078 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 25.34 | 0.00879 |
G S1 APARTMENT | 1367.94 | 1641.53 | 0.109 | 0.130 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 29.27 | 0.00879 |
G S2 APARTMENT | 1401.04 | 1681.25 | 0.111 | 0.134 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 29.14 | 0.00879 |
M SW APARTMENT | 5155.17 | 6186.21 | 0.410 | 0.491 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 28.36 | 0.00879 |
M NW APARTMENT | 4102.92 | 4923.50 | 0.326 | 0.391 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 26.90 | 0.00879 |
M SE APARTMENT | 4787.29 | 5744.75 | 0.380 | 0.456 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 29.14 | 0.00879 |
M NE APARTMENT | 3060.20 | 3672.24 | 0.243 | 0.292 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 10:15:00 | 25.84 | 0.00879 |
M N1 APARTMENT | 2431.08 | 2917.30 | 0.193 | 0.232 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 25.34 | 0.00879 |
M N2 APARTMENT | 2410.32 | 2892.38 | 0.191 | 0.230 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 25.34 | 0.00879 |
M S1 APARTMENT | 3887.26 | 4664.71 | 0.309 | 0.371 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 29.27 | 0.00879 |
M S2 APARTMENT | 3900.46 | 4680.55 | 0.310 | 0.372 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 29.27 | 0.00879 |
T SW APARTMENT | 3383.54 | 4060.24 | 0.269 | 0.323 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 29.09 | 0.00879 |
T NW APARTMENT | 2629.37 | 3155.25 | 0.209 | 0.251 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 17:30:00 | 27.42 | 0.00879 |
T SE APARTMENT | 3171.97 | 3806.36 | 0.252 | 0.302 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 29.27 | 0.00879 |
T NE APARTMENT | 1965.13 | 2358.15 | 0.156 | 0.187 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 29.40 | 0.00879 |
T N1 APARTMENT | 1561.69 | 1874.03 | 0.124 | 0.149 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 29.09 | 0.00879 |
T N2 APARTMENT | 1558.24 | 1869.89 | 0.124 | 0.149 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 15:15:00 | 29.24 | 0.00879 |
T S1 APARTMENT | 2732.15 | 3278.58 | 0.217 | 0.260 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 29.40 | 0.00879 |
T S2 APARTMENT | 2740.80 | 3288.96 | 0.218 | 0.261 | SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 29.40 | 0.00879 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 944.76 | 1133.71 | 0.028 | 0.033 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
G NW APARTMENT | 951.38 | 1141.66 | 0.028 | 0.033 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
OFFICE | 2236.08 | 2683.29 | 0.063 | 0.075 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -4.20 | 0.00269 |
G NE APARTMENT | 955.58 | 1146.70 | 0.028 | 0.033 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
G N1 APARTMENT | 531.04 | 637.25 | 0.016 | 0.026 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
G N2 APARTMENT | 531.14 | 637.37 | 0.016 | 0.026 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
G S1 APARTMENT | 525.58 | 630.70 | 0.015 | 0.026 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
G S2 APARTMENT | 605.13 | 726.16 | 0.018 | 0.026 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M SW APARTMENT | 1854.30 | 2225.16 | 0.054 | 0.065 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M NW APARTMENT | 1873.81 | 2248.57 | 0.055 | 0.066 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M SE APARTMENT | 1865.60 | 2238.72 | 0.054 | 0.065 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M NE APARTMENT | 1885.10 | 2262.12 | 0.055 | 0.066 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M N1 APARTMENT | 806.60 | 967.92 | 0.024 | 0.052 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M N2 APARTMENT | 806.91 | 968.29 | 0.024 | 0.052 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M S1 APARTMENT | 788.36 | 946.03 | 0.023 | 0.052 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
M S2 APARTMENT | 788.67 | 946.40 | 0.023 | 0.052 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T SW APARTMENT | 1840.25 | 2208.30 | 0.054 | 0.064 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T NW APARTMENT | 1851.64 | 2221.96 | 0.054 | 0.065 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T SE APARTMENT | 1846.09 | 2215.31 | 0.054 | 0.065 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T NE APARTMENT | 1857.48 | 2228.98 | 0.054 | 0.065 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T N1 APARTMENT | 1281.78 | 1538.13 | 0.037 | 0.045 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T N2 APARTMENT | 1281.94 | 1538.33 | 0.037 | 0.045 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T S1 APARTMENT | 1268.63 | 1522.35 | 0.037 | 0.044 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
T S2 APARTMENT | 1268.80 | 1522.55 | 0.037 | 0.044 | SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -4.20 | 0.00269 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.18 | 0.18 | 0.03 | 0.03 |
SPLIT GNW | 0.14 | 0.14 | 0.03 | 0.03 |
SPLIT OFFICE | 0.45 | 0.45 | 0.08 | 0.08 |
SPLIT GNE | 0.10 | 0.10 | 0.03 | 0.03 |
SPLIT GN1 | 0.08 | 0.08 | 0.03 | 0.03 |
SPLIT GN2 | 0.08 | 0.08 | 0.03 | 0.03 |
SPLIT GS1 | 0.13 | 0.13 | 0.03 | 0.03 |
SPLIT GS2 | 0.13 | 0.13 | 0.03 | 0.03 |
SPLIT MSW | 0.49 | 0.49 | 0.06 | 0.06 |
SPLIT MNW | 0.39 | 0.39 | 0.07 | 0.07 |
SPLIT MSE | 0.46 | 0.46 | 0.07 | 0.07 |
SPLIT MNE | 0.29 | 0.29 | 0.07 | 0.07 |
SPLIT MN1 | 0.23 | 0.23 | 0.05 | 0.05 |
SPLIT MN2 | 0.23 | 0.23 | 0.05 | 0.05 |
SPLIT MS1 | 0.37 | 0.37 | 0.05 | 0.05 |
SPLIT MS2 | 0.37 | 0.37 | 0.05 | 0.05 |
SPLIT TSW | 0.32 | 0.32 | 0.06 | 0.06 |
SPLIT TNW | 0.25 | 0.25 | 0.06 | 0.06 |
SPLIT TSE | 0.30 | 0.30 | 0.06 | 0.06 |
SPLIT TNE | 0.19 | 0.19 | 0.07 | 0.07 |
SPLIT TN1 | 0.15 | 0.15 | 0.04 | 0.04 |
SPLIT TN2 | 0.15 | 0.15 | 0.04 | 0.04 |
SPLIT TS1 | 0.26 | 0.26 | 0.04 | 0.04 |
SPLIT TS2 | 0.26 | 0.26 | 0.04 | 0.04 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 1180.00 | 6217.50 | 70.25 |
G NW APARTMENT | 886.25 | 6637.75 | 156.25 |
OFFICE | 130.25 | 1722.00 | 18.25 |
G NE APARTMENT | 842.75 | 6764.00 | 147.75 |
G N1 APARTMENT | 505.25 | 6803.50 | 18.50 |
G N2 APARTMENT | 502.75 | 6813.25 | 18.25 |
G S1 APARTMENT | 961.00 | 6187.25 | 0.00 |
G S2 APARTMENT | 922.00 | 6220.75 | 3.50 |
M SW APARTMENT | 2678.00 | 3801.50 | 0.00 |
M NW APARTMENT | 2151.50 | 4653.50 | 0.00 |
M SE APARTMENT | 2673.50 | 3838.25 | 0.00 |
M NE APARTMENT | 2130.00 | 4767.75 | 0.00 |
M N1 APARTMENT | 2003.75 | 4346.00 | 0.00 |
M N2 APARTMENT | 1991.75 | 4358.50 | 0.00 |
M S1 APARTMENT | 2659.00 | 3180.50 | 0.00 |
M S2 APARTMENT | 2659.50 | 3185.00 | 0.00 |
T SW APARTMENT | 2289.75 | 5188.50 | 302.50 |
T NW APARTMENT | 2140.50 | 5840.75 | 513.25 |
T SE APARTMENT | 2304.25 | 5222.00 | 305.25 |
T NE APARTMENT | 2115.00 | 5990.00 | 503.50 |
T N1 APARTMENT | 1744.00 | 5852.50 | 225.75 |
T N2 APARTMENT | 1739.00 | 5864.00 | 226.00 |
T S1 APARTMENT | 2082.75 | 4928.00 | 108.00 |
T S2 APARTMENT | 2079.00 | 4932.25 | 108.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 3589.00 | 7056.00 | 544.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 10.75 | 0.00 | 10.75 | 0.00 |
G NW APARTMENT | 12.75 | 0.00 | 12.75 | 0.00 |
OFFICE | 2.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 12.25 | 0.00 | 12.25 | 0.00 |
G N1 APARTMENT | 4.75 | 0.00 | 4.75 | 0.00 |
G N2 APARTMENT | 5.25 | 0.00 | 5.25 | 0.00 |
G S1 APARTMENT | 8.00 | 0.00 | 8.00 | 0.00 |
G S2 APARTMENT | 7.25 | 0.00 | 7.25 | 0.00 |
M SW APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
M NW APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
M SE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M NE APARTMENT | 6.00 | 0.00 | 6.00 | 0.00 |
M N1 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M N2 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M S2 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
T NE APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
T N1 APARTMENT | 13.00 | 0.00 | 13.00 | 0.00 |
T N2 APARTMENT | 12.75 | 0.00 | 12.75 | 0.00 |
T S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T S2 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 88.25 | 0.00 | 86.25 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.366 | 0.094 | 0.000 | 0.067 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.094 | 0.000 | 0.066 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.520 | 0.100 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.094 | 0.000 | 0.066 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.057 | 0.000 | 0.065 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.057 | 0.000 | 0.065 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.057 | 0.000 | 0.067 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.057 | 0.000 | 0.067 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.135 | 0.000 | 0.078 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.135 | 0.000 | 0.078 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.135 | 0.000 | 0.078 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.135 | 0.000 | 0.078 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.082 | 0.000 | 0.078 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.082 | 0.000 | 0.078 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.082 | 0.000 | 0.078 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.082 | 0.000 | 0.078 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.179 | 0.000 | 0.088 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.088 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.179 | 0.000 | 0.088 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.088 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.108 | 0.000 | 0.088 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.108 | 0.000 | 0.088 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.108 | 0.000 | 0.088 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.108 | 0.000 | 0.088 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.503 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.369 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.368 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 405.21 | 0.00 | 01-JAN-00:15 | 32493.08 | 05-FEB-07:45 |
WaterSystems:Electricity | 405.21 | 0.00 | 01-JAN-00:15 | 32493.08 | 05-FEB-07:45 |
Water Heater:WaterSystems:Electricity | 405.21 | 0.00 | 01-JAN-00:15 | 32493.08 | 05-FEB-07:45 |
Fans:Electricity | 211.94 | 6720.50 | 05-JAN-17:15 | 6720.50 | 03-JAN-17:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
ElectricityPurchased:Plant | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
Cogeneration:ElectricityPurchased | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
ElectricityNet:Plant | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
Cogeneration:ElectricityNet | 1399.68 | 20090.79 | 01-JAN-03:15 | 83445.56 | 10-AUG-17:30 |
ExteriorLights:Electricity | 39.36 | 0.00 | 01-JAN-08:15 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.36 | 0.00 | 01-JAN-08:15 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 278.68 | 6720.50 | 05-JAN-17:15 | 25901.44 | 29-AUG-15:15 |
General:Fans:Electricity | 211.94 | 6720.50 | 05-JAN-17:15 | 6720.50 | 03-JAN-17:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 66.74 | 0.00 | 01-JAN-00:15 | 19180.94 | 29-AUG-15:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 146.96 | 0.00 | 11-JAN-17:30 | 52217.55 | 19-FEB-06:00 |
Gas:HVAC | 146.96 | 0.00 | 11-JAN-17:30 | 52217.55 | 19-FEB-06:00 |
Heating:Gas | 146.96 | 0.00 | 11-JAN-17:30 | 52217.55 | 19-FEB-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:30 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 785.16 | 2282.32 | 08-MAR-18:00 | 133672.02 | 10-AUG-15:15 |
EnergyTransfer:Building | 398.98 | 1987.70 | 08-MAR-18:00 | 58857.19 | 10-AUG-16:15 |
EnergyTransfer:Zone:G SW APARTMENT | 8.23 | 0.01 | 07-DEC-19:45 | 2003.01 | 10-AUG-16:15 |
Heating:EnergyTransfer | 46.38 | 0.00 | 01-FEB-13:15 | 21795.59 | 19-FEB-04:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 1.79 | 0.00 | 02-JAN-19:30 | 780.94 | 19-FEB-04:00 |
Cooling:EnergyTransfer | 352.59 | 75.70 | 28-JAN-03:45 | 58857.19 | 10-AUG-16:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 6.44 | 0.00 | 01-JAN-00:15 | 2003.01 | 10-AUG-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 7.11 | 0.05 | 08-OCT-12:45 | 1669.94 | 10-AUG-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 2.61 | 0.00 | 02-JAN-19:30 | 876.90 | 19-FEB-08:15 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.49 | 0.00 | 01-JAN-00:15 | 1669.94 | 10-AUG-17:30 |
EnergyTransfer:Zone:OFFICE | 17.99 | 0.03 | 28-APR-02:00 | 3339.07 | 29-AUG-12:30 |
Heating:EnergyTransfer:Zone:OFFICE | 0.15 | 0.00 | 01-JAN-00:15 | 1702.22 | 16-JAN-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 17.84 | 0.00 | 02-JAN-07:30 | 3339.07 | 29-AUG-12:30 |
EnergyTransfer:Zone:G NE APARTMENT | 7.33 | 0.01 | 30-MAR-09:00 | 1144.95 | 24-JUL-18:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 2.60 | 0.00 | 02-JAN-19:30 | 834.28 | 19-FEB-04:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.73 | 0.00 | 01-JAN-00:15 | 1144.95 | 24-JUL-18:00 |
EnergyTransfer:Zone:G N1 APARTMENT | 6.00 | 0.02 | 08-NOV-01:45 | 921.46 | 24-JUL-18:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.78 | 0.00 | 01-JAN-16:15 | 464.37 | 19-FEB-08:15 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 5.23 | 0.00 | 01-JAN-00:15 | 921.46 | 24-JUL-18:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 6.01 | 0.05 | 31-MAY-13:00 | 915.00 | 24-JUL-18:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.78 | 0.00 | 01-JAN-16:15 | 460.76 | 19-FEB-08:15 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 5.23 | 0.00 | 01-JAN-00:15 | 915.00 | 24-JUL-18:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 7.46 | 0.03 | 13-MAY-15:15 | 1289.98 | 29-AUG-12:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.40 | 0.00 | 01-JAN-10:30 | 394.22 | 19-FEB-04:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 7.06 | 0.00 | 01-JAN-00:15 | 1289.98 | 29-AUG-12:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 7.37 | 0.02 | 25-JAN-11:00 | 1283.58 | 29-AUG-12:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.48 | 0.00 | 01-JAN-17:15 | 466.65 | 19-FEB-04:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 6.88 | 0.00 | 01-JAN-00:15 | 1283.58 | 29-AUG-12:30 |
EnergyTransfer:Zone:M SW APARTMENT | 31.48 | 0.43 | 02-DEC-05:30 | 5476.70 | 10-AUG-17:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.85 | 0.00 | 01-JAN-10:15 | 1207.33 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 30.62 | 0.00 | 01-JAN-00:15 | 5476.70 | 10-AUG-17:15 |
EnergyTransfer:Zone:M NW APARTMENT | 23.31 | 0.11 | 20-DEC-22:00 | 4522.47 | 10-AUG-17:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 1.77 | 0.00 | 01-JAN-10:30 | 1412.14 | 19-FEB-06:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.53 | 0.00 | 01-JAN-00:15 | 4522.47 | 10-AUG-17:30 |
EnergyTransfer:Zone:M SE APARTMENT | 31.39 | 0.07 | 01-OCT-09:45 | 4635.54 | 10-AUG-12:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.87 | 0.00 | 01-JAN-10:15 | 1202.90 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 30.52 | 0.00 | 01-JAN-00:15 | 4635.54 | 10-AUG-12:30 |
EnergyTransfer:Zone:M NE APARTMENT | 23.66 | 0.00 | 15-FEB-13:15 | 3453.66 | 24-JUL-18:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 1.80 | 0.00 | 01-JAN-10:15 | 1403.20 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 21.86 | 0.00 | 01-JAN-00:15 | 3453.66 | 24-JUL-18:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 24.51 | 0.68 | 18-MAR-14:45 | 2766.95 | 24-JUL-18:30 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.08 | 0.00 | 01-JAN-02:45 | 718.34 | 19-FEB-24:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 24.42 | 0.00 | 01-JAN-00:15 | 2766.95 | 24-JUL-18:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 24.46 | 0.16 | 18-MAR-15:45 | 2756.37 | 24-JUL-18:30 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.08 | 0.00 | 01-JAN-02:45 | 722.20 | 08-JAN-03:15 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 24.38 | 0.00 | 01-JAN-00:15 | 2756.37 | 24-JUL-18:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 33.88 | 1.02 | 14-JAN-04:15 | 3827.34 | 23-SEP-13:30 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:45 | 476.27 | 16-FEB-04:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 33.87 | 0.00 | 01-JAN-00:15 | 3827.34 | 23-SEP-13:30 |
EnergyTransfer:Zone:M S2 APARTMENT | 33.85 | 1.12 | 14-JAN-04:15 | 3833.45 | 23-SEP-13:30 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:45 | 473.62 | 16-FEB-04:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 33.84 | 0.00 | 01-JAN-00:15 | 3833.45 | 23-SEP-13:30 |
EnergyTransfer:Zone:T SW APARTMENT | 15.51 | 0.01 | 14-APR-22:45 | 3567.86 | 10-AUG-16:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 4.66 | 0.00 | 05-JAN-13:15 | 1686.36 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 10.85 | 0.00 | 01-JAN-00:15 | 3567.86 | 10-AUG-16:15 |
EnergyTransfer:Zone:T NW APARTMENT | 13.59 | 0.06 | 03-NOV-22:00 | 2993.33 | 10-AUG-17:15 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 6.11 | 0.00 | 11-JAN-17:00 | 1739.55 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 7.48 | 0.00 | 01-JAN-00:15 | 2993.33 | 10-AUG-17:15 |
EnergyTransfer:Zone:T SE APARTMENT | 15.35 | 0.01 | 18-SEP-03:15 | 3103.67 | 10-AUG-14:15 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 4.62 | 0.00 | 03-JAN-10:45 | 1688.53 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 10.73 | 0.00 | 01-JAN-00:15 | 3103.67 | 10-AUG-14:15 |
EnergyTransfer:Zone:T NE APARTMENT | 13.75 | 0.00 | 21-NOV-19:15 | 2215.54 | 24-JUL-16:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 6.11 | 0.00 | 11-JAN-15:45 | 1742.80 | 19-FEB-07:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 7.65 | 0.00 | 01-JAN-00:15 | 2215.54 | 24-JUL-16:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 10.51 | 0.05 | 03-MAR-07:45 | 1877.75 | 20-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 2.97 | 0.00 | 02-JAN-18:15 | 1142.99 | 19-FEB-06:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.54 | 0.00 | 01-JAN-00:15 | 1877.75 | 20-JUL-17:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 10.49 | 0.03 | 27-FEB-14:15 | 1857.70 | 20-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 2.97 | 0.00 | 02-JAN-18:15 | 1142.54 | 19-FEB-06:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.52 | 0.00 | 01-JAN-00:15 | 1857.70 | 20-JUL-17:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 12.88 | 0.04 | 09-NOV-01:15 | 2699.38 | 10-AUG-14:15 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 1.93 | 0.00 | 01-JAN-18:15 | 1081.81 | 19-FEB-06:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 10.95 | 0.00 | 01-JAN-00:15 | 2699.38 | 10-AUG-14:15 |
EnergyTransfer:Zone:T S2 APARTMENT | 12.88 | 0.00 | 23-FEB-23:45 | 2704.52 | 10-AUG-14:15 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 1.93 | 0.00 | 01-JAN-18:15 | 1081.57 | 19-FEB-06:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 10.94 | 0.00 | 01-JAN-00:15 | 2704.52 | 10-AUG-14:15 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 386.18 | 0.00 | 11-JAN-17:30 | 75568.38 | 29-AUG-15:15 |
HeatingCoils:EnergyTransfer | 117.57 | 0.00 | 11-JAN-17:30 | 41774.04 | 19-FEB-06:00 |
CoolingCoils:EnergyTransfer | 268.61 | 0.00 | 01-JAN-00:15 | 75568.38 | 29-AUG-15:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 1.794 | -6.436 | 0.000 | 0.000 | 3.857 | 2.413 | 12.213 | 11.050 | 0.000 | 0.022 | 0.000 | 0.000 | -6.808 | 0.000 | -4.031 | -14.074 |
G NW APARTMENT | 2.614 | -4.493 | 0.000 | 0.000 | 3.888 | 2.413 | 12.213 | 5.517 | 0.000 | 0.022 | 0.000 | 0.000 | -6.842 | 0.000 | -3.929 | -11.405 |
OFFICE | 0.152 | -17.837 | 0.000 | 0.000 | 0.522 | 21.914 | 7.534 | 10.745 | 0.000 | 0.017 | 0.000 | 0.000 | -6.666 | 0.000 | -3.014 | -13.367 |
G NE APARTMENT | 2.601 | -4.726 | 0.000 | 0.000 | 3.903 | 2.413 | 12.213 | 5.204 | 0.000 | 0.022 | 0.000 | 0.000 | -6.707 | 0.000 | -3.908 | -11.015 |
G N1 APARTMENT | 0.779 | -5.225 | 0.000 | 0.000 | 3.897 | 2.413 | 12.213 | 1.896 | 0.000 | 0.018 | 0.000 | 0.000 | -4.197 | 0.000 | -2.705 | -9.088 |
G N2 APARTMENT | 0.780 | -5.226 | 0.000 | 0.000 | 3.898 | 2.413 | 12.213 | 1.896 | 0.000 | 0.018 | 0.000 | 0.000 | -4.196 | 0.000 | -2.704 | -9.091 |
G S1 APARTMENT | 0.401 | -7.059 | 0.000 | 0.000 | 3.850 | 2.413 | 12.213 | 7.472 | 0.000 | 0.017 | 0.000 | 0.000 | -4.167 | 0.000 | -2.826 | -12.314 |
G S2 APARTMENT | 0.481 | -6.884 | 0.000 | 0.000 | 3.850 | 2.413 | 12.213 | 7.473 | 0.000 | 0.017 | 0.000 | 0.000 | -4.162 | 0.000 | -2.827 | -12.573 |
M SW APARTMENT | 0.854 | -30.622 | 0.000 | 0.000 | 3.695 | 2.413 | 12.213 | 10.583 | 0.000 | 0.030 | 14.300 | 0.000 | -7.635 | 0.000 | -5.831 | -0.000 |
M NW APARTMENT | 1.775 | -21.533 | 0.000 | 0.000 | 3.749 | 2.413 | 12.213 | 5.123 | 0.000 | 0.030 | 9.526 | 0.000 | -7.575 | 0.000 | -5.721 | -0.000 |
M SE APARTMENT | 0.871 | -30.521 | 0.000 | 0.000 | 3.700 | 2.413 | 12.213 | 10.279 | 0.000 | 0.030 | 14.356 | 0.000 | -7.516 | 0.000 | -5.825 | -0.000 |
M NE APARTMENT | 1.799 | -21.863 | 0.000 | 0.000 | 3.764 | 2.413 | 12.213 | 4.805 | 0.000 | 0.030 | 9.944 | 0.000 | -7.410 | 0.000 | -5.695 | -0.001 |
M N1 APARTMENT | 0.082 | -24.425 | 0.000 | 0.000 | 3.727 | 2.413 | 12.213 | 1.651 | 0.000 | 0.022 | 13.002 | 0.000 | -4.737 | 0.000 | -3.949 | -0.000 |
M N2 APARTMENT | 0.080 | -24.382 | 0.000 | 0.000 | 3.729 | 2.413 | 12.213 | 1.651 | 0.000 | 0.022 | 12.955 | 0.000 | -4.734 | 0.000 | -3.947 | -0.000 |
M S1 APARTMENT | 0.012 | -33.868 | 0.000 | 0.000 | 3.652 | 2.413 | 12.213 | 7.172 | 0.000 | 0.023 | 17.157 | 0.000 | -4.733 | 0.000 | -4.039 | -0.000 |
M S2 APARTMENT | 0.011 | -33.836 | 0.000 | 0.000 | 3.652 | 2.413 | 12.213 | 7.172 | 0.000 | 0.023 | 17.123 | 0.000 | -4.732 | 0.000 | -4.039 | -0.000 |
T SW APARTMENT | 4.660 | -10.849 | 0.000 | 0.000 | 3.795 | 2.413 | 12.213 | 10.562 | 0.000 | 0.040 | 0.000 | 0.000 | -7.089 | 0.000 | -7.219 | -8.526 |
T NW APARTMENT | 6.111 | -7.480 | 0.000 | 0.000 | 3.838 | 2.413 | 12.213 | 5.135 | 0.000 | 0.040 | 0.000 | 0.000 | -7.056 | 0.000 | -7.093 | -8.122 |
T SE APARTMENT | 4.623 | -10.730 | 0.000 | 0.000 | 3.801 | 2.413 | 12.213 | 10.279 | 0.000 | 0.040 | 0.000 | 0.000 | -6.990 | 0.000 | -7.214 | -8.436 |
T NE APARTMENT | 6.107 | -7.645 | 0.000 | 0.000 | 3.856 | 2.413 | 12.213 | 4.845 | 0.000 | 0.040 | 0.000 | 0.000 | -6.916 | 0.000 | -7.063 | -7.849 |
T N1 APARTMENT | 2.967 | -7.540 | 0.000 | 0.000 | 3.835 | 2.413 | 12.213 | 1.693 | 0.000 | 0.030 | 0.000 | 0.000 | -4.351 | 0.000 | -4.782 | -6.476 |
T N2 APARTMENT | 2.971 | -7.519 | 0.000 | 0.000 | 3.836 | 2.413 | 12.213 | 1.692 | 0.000 | 0.030 | 0.000 | 0.000 | -4.348 | 0.000 | -4.782 | -6.506 |
T S1 APARTMENT | 1.929 | -10.949 | 0.000 | 0.000 | 3.770 | 2.413 | 12.213 | 7.177 | 0.000 | 0.030 | 0.000 | 0.000 | -4.383 | 0.000 | -4.906 | -7.295 |
T S2 APARTMENT | 1.933 | -10.942 | 0.000 | 0.000 | 3.771 | 2.413 | 12.213 | 7.176 | 0.000 | 0.030 | 0.000 | 0.000 | -4.382 | 0.000 | -4.906 | -7.305 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.043 | 0.000 | 0.001 | 0.000 | 0.000 | -0.894 | 0.000 | -1.115 | -15.105 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 0.183 | 0.000 | 0.047 | 0.000 | 0.000 | -2.327 | 0.000 | -19.582 | -1.656 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.042 | 0.000 | 0.001 | 0.000 | 0.000 | -0.998 | 0.000 | -0.932 | -15.183 |
Total Facility | 46.384 | -352.591 | 0.000 | 0.000 | 87.835 | 128.627 | 294.692 | 148.516 | 0.000 | 0.692 | 108.364 | 0.000 | -142.551 | 0.000 | -134.585 | -185.384 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 10-AUG-16:15 | 0.00 | -2004.13 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2286.28 | 0.00 | 25.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1124.95 |
G NW APARTMENT | 10-AUG-17:23 | 0.00 | -1670.05 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1853.40 | 0.00 | 36.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1144.87 |
OFFICE | 29-AUG-12:30 | 0.00 | -3339.16 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 2449.85 | 0.00 | 30.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1376.00 |
G NE APARTMENT | 24-JUL-18:00 | 0.00 | -1144.95 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 574.12 | 0.00 | 43.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -397.19 |
G N1 APARTMENT | 24-JUL-18:15 | 0.00 | -921.45 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 389.23 | 0.00 | 23.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -411.26 |
G N2 APARTMENT | 24-JUL-18:15 | 0.00 | -914.99 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 389.34 | 0.00 | 23.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.83 |
G S1 APARTMENT | 29-AUG-12:30 | 0.00 | -1289.90 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2201.19 | 0.00 | 16.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1385.93 |
G S2 APARTMENT | 29-AUG-12:30 | 0.00 | -1283.50 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2201.30 | 0.00 | 16.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1392.44 |
M SW APARTMENT | 10-AUG-17:10 | 0.00 | -5477.67 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1894.05 | 0.00 | 54.57 | 2604.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 10-AUG-17:30 | 0.00 | -4522.73 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1839.75 | 0.00 | 52.51 | 1705.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 10-AUG-12:30 | 0.00 | -4635.73 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2105.72 | 0.00 | 75.21 | 1996.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 24-JUL-18:00 | 0.00 | -3453.65 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 560.01 | 0.00 | 61.72 | 1907.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 24-JUL-18:30 | 0.00 | -2766.88 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 388.06 | 0.00 | 30.94 | 1428.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 24-JUL-18:30 | 0.00 | -2756.30 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 388.13 | 0.00 | 30.94 | 1417.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 23-SEP-13:30 | 0.00 | -3827.27 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2093.64 | 0.00 | 0.00 | 1318.07 | 0.00 | 0.00 | 0.00 | -36.60 | 0.00 |
M S2 APARTMENT | 23-SEP-13:30 | 0.00 | -3833.38 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2093.60 | 0.00 | 0.00 | 1324.22 | 0.00 | 0.00 | 0.00 | -36.60 | 0.00 |
T SW APARTMENT | 10-AUG-16:08 | 0.00 | -3568.48 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2235.41 | 0.00 | 47.85 | 467.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 10-AUG-17:15 | 0.00 | -2994.17 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 1868.47 | 0.00 | 71.78 | 129.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 10-AUG-14:15 | 0.00 | -3103.57 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1745.25 | 0.00 | 38.48 | 828.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 24-JUL-16:08 | 0.00 | -2215.68 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 621.80 | 0.00 | 76.10 | 700.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 20-JUL-17:30 | 0.00 | -1878.03 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 342.03 | 0.00 | 149.72 | 461.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 20-JUL-17:30 | 0.00 | -1857.97 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 342.34 | 0.00 | 149.72 | 441.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 10-AUG-14:15 | 0.00 | -2699.28 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1532.71 | 0.00 | 23.21 | 651.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 10-AUG-14:15 | 0.00 | -2704.42 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1532.62 | 0.00 | 23.21 | 657.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 10-AUG-16:15 | 0.00 | -58868.92 | 0.00 | 0.00 | 1949.41 | 5316.35 | 14137.32 | 21833.25 | 0.00 | 1725.15 | 13907.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 19-FEB-04:00 | 780.92 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -709.22 | 0.00 | -255.04 | -244.42 |
G NW APARTMENT | 29-OCT-06:01 | 1594.29 | 0.00 | 0.00 | 0.00 | 163.28 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -389.92 | 0.00 | -83.77 | -1760.11 |
OFFICE | 17-DEC-07:01 | 3456.59 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -341.36 | 0.00 | -191.99 | -3497.82 |
G NE APARTMENT | 31-OCT-16:01 | 1620.19 | 0.00 | 0.00 | 0.00 | 99.85 | 144.04 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -283.53 | 0.00 | -259.29 | -1909.88 |
G N1 APARTMENT | 29-MAR-06:01 | 1222.72 | 0.00 | 0.00 | 0.00 | 161.33 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -226.93 | 0.00 | -121.29 | -1512.07 |
G N2 APARTMENT | 29-MAR-06:01 | 1221.68 | 0.00 | 0.00 | 0.00 | 161.33 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -226.93 | 0.00 | -121.28 | -1511.03 |
G S1 APARTMENT | 16-DEC-17:01 | 1350.88 | 0.00 | 0.00 | 0.00 | 99.83 | 144.04 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -306.92 | 0.00 | -100.99 | -1775.47 |
G S2 APARTMENT | 29-NOV-07:01 | 1363.14 | 0.00 | 0.00 | 0.00 | 163.18 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -236.04 | 0.00 | -171.92 | -1594.59 |
M SW APARTMENT | 19-DEC-07:01 | 3113.35 | 0.00 | 0.00 | 0.00 | 163.04 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -481.44 | 0.00 | -115.20 | -3155.99 |
M NW APARTMENT | 19-FEB-06:00 | 1412.07 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -754.02 | 0.00 | -422.09 | -772.36 |
M SE APARTMENT | 21-FEB-07:01 | 1245.08 | 0.00 | 0.00 | 0.00 | 161.66 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -380.52 | 0.00 | -173.51 | -1328.94 |
M NE APARTMENT | 06-MAR-07:01 | 3168.36 | 0.00 | 0.00 | 0.00 | 163.12 | 93.63 | 382.60 | 41.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -290.22 | -3559.32 |
M N1 APARTMENT | 07-JAN-08:28 | 1977.27 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -382.37 | 0.00 | -121.70 | -1978.87 |
M N2 APARTMENT | 07-JAN-08:26 | 1980.72 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -382.35 | 0.00 | -121.71 | -1982.34 |
M S1 APARTMENT | 16-FEB-04:00 | 476.20 | 0.00 | 0.00 | 0.00 | 191.99 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -306.30 | 0.00 | -317.42 | -282.56 |
M S2 APARTMENT | 16-FEB-04:00 | 473.55 | 0.00 | 0.00 | 0.00 | 191.98 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -306.31 | 0.00 | -317.42 | -279.88 |
T SW APARTMENT | 19-FEB-07:00 | 1686.31 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -689.51 | 0.00 | -616.81 | -988.34 |
T NW APARTMENT | 19-FEB-07:00 | 1739.50 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -701.27 | 0.00 | -616.81 | -1029.77 |
T SE APARTMENT | 19-FEB-07:00 | 1688.48 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -699.50 | 0.00 | -616.81 | -980.52 |
T NE APARTMENT | 19-FEB-07:00 | 1742.76 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -711.21 | 0.00 | -616.81 | -1023.09 |
T N1 APARTMENT | 17-APR-06:01 | 1966.66 | 0.00 | 0.00 | 0.00 | 163.42 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -216.10 | 0.00 | -108.27 | -2281.93 |
T N2 APARTMENT | 03-MAR-07:01 | 1963.35 | 0.00 | 0.00 | 0.00 | 163.36 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -214.75 | 0.00 | -115.02 | -2273.17 |
T S1 APARTMENT | 05-MAR-17:01 | 1250.28 | 0.00 | 0.00 | 0.00 | 99.38 | 144.04 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -222.94 | 0.00 | -129.70 | -1729.68 |
T S2 APARTMENT | 18-MAR-06:01 | 1790.31 | 0.00 | 0.00 | 0.00 | 162.72 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -302.52 | 0.00 | -145.34 | -1981.40 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 19-FEB-04:00 | 21284.44 | 0.00 | 0.00 | 0.00 | 4362.43 | 2334.74 | 5313.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14111.25 | 0.00 | -7258.44 | -11925.58 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sec1.1A-General InformationData | |
Weather File | Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 86.25 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 86.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 146.96 | 52217.55 | 0.00 | 0.00 |
Space Cooling | 66.74 | 18773.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 211.94 | 6720.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 405.21 | 22922.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1399.68 | 146.96 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1399.68 |
Natural Gas | 0.00 | 146.96 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1546.64 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 21.29 |
Fans-Interior | 67.61 |
Service Water Heating | 129.27 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.56 |
Subtotal | 446.52 |
Natural Gas [MJ/m2] | |
Space Heating | 46.88 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 46.88 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 10.67 |
Space Heating | 9.50 |
Space Cooling | 4.32 |
Fans-Interior | 13.70 |
Service Water Heating | 26.20 |
Receptacle Equipment | 33.07 |
Miscellaneous | 2.55 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.177225 |
G NW APARTMENT DIRECT AIR | 0.141589 |
OFFICE DIRECT AIR | 0.447039 |
G NE APARTMENT DIRECT AIR | 0.096121 |
G N1 APARTMENT DIRECT AIR | 0.079148 |
G N2 APARTMENT DIRECT AIR | 0.078044 |
G S1 APARTMENT DIRECT AIR | 0.130406 |
G S2 APARTMENT DIRECT AIR | 0.133562 |
M SW APARTMENT DIRECT AIR | 0.491446 |
M NW APARTMENT DIRECT AIR | 0.391131 |
M SE APARTMENT DIRECT AIR | 0.456376 |
M NE APARTMENT DIRECT AIR | 0.291734 |
M N1 APARTMENT DIRECT AIR | 0.231755 |
M N2 APARTMENT DIRECT AIR | 0.229776 |
M S1 APARTMENT DIRECT AIR | 0.370574 |
M S2 APARTMENT DIRECT AIR | 0.371832 |
T SW APARTMENT DIRECT AIR | 0.322556 |
T NW APARTMENT DIRECT AIR | 0.250659 |
T SE APARTMENT DIRECT AIR | 0.302387 |
T NE APARTMENT DIRECT AIR | 0.187338 |
T N1 APARTMENT DIRECT AIR | 0.148877 |
T N2 APARTMENT DIRECT AIR | 0.148548 |
T S1 APARTMENT DIRECT AIR | 0.260458 |
T S2 APARTMENT DIRECT AIR | 0.261282 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.177225 |
SPLIT GNW MAIN BRANCH | 0.141589 |
SPLIT OFFICE MAIN BRANCH | 0.447039 |
SPLIT GNE MAIN BRANCH | 0.096121 |
SPLIT GN1 MAIN BRANCH | 0.079148 |
SPLIT GN2 MAIN BRANCH | 0.078044 |
SPLIT GS1 MAIN BRANCH | 0.130406 |
SPLIT GS2 MAIN BRANCH | 0.133562 |
SPLIT MSW MAIN BRANCH | 0.491446 |
SPLIT MNW MAIN BRANCH | 0.391131 |
SPLIT MSE MAIN BRANCH | 0.456376 |
SPLIT MNE MAIN BRANCH | 0.291734 |
SPLIT MN1 MAIN BRANCH | 0.231755 |
SPLIT MN2 MAIN BRANCH | 0.229776 |
SPLIT MS1 MAIN BRANCH | 0.370574 |
SPLIT MS2 MAIN BRANCH | 0.371832 |
SPLIT TSW MAIN BRANCH | 0.322556 |
SPLIT TNW MAIN BRANCH | 0.250659 |
SPLIT TSE MAIN BRANCH | 0.302387 |
SPLIT TNE MAIN BRANCH | 0.187338 |
SPLIT TN1 MAIN BRANCH | 0.148877 |
SPLIT TN2 MAIN BRANCH | 0.148548 |
SPLIT TS1 MAIN BRANCH | 0.260458 |
SPLIT TS2 MAIN BRANCH | 0.261282 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.177225 |
SPLIT GNW | 0.141589 |
SPLIT OFFICE | 0.447039 |
SPLIT GNE | 0.096121 |
SPLIT GN1 | 0.079148 |
SPLIT GN2 | 0.078044 |
SPLIT GS1 | 0.130406 |
SPLIT GS2 | 0.133562 |
SPLIT MSW | 0.491446 |
SPLIT MNW | 0.391131 |
SPLIT MSE | 0.456376 |
SPLIT MNE | 0.291734 |
SPLIT MN1 | 0.231755 |
SPLIT MN2 | 0.229776 |
SPLIT MS1 | 0.370574 |
SPLIT MS2 | 0.371832 |
SPLIT TSW | 0.322556 |
SPLIT TNW | 0.250659 |
SPLIT TSE | 0.302387 |
SPLIT TNE | 0.187338 |
SPLIT TN1 | 0.148877 |
SPLIT TN2 | 0.148548 |
SPLIT TS1 | 0.260458 |
SPLIT TS2 | 0.261282 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.177225 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.141589 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.447039 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.096121 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.079148 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.078044 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.130406 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.133562 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.491446 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.391131 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.456376 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.291734 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.231755 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.229776 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.370574 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.371832 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.322556 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.250659 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.302387 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.187338 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.148877 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.148548 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.260458 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.261282 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.177225 | 2933.70 | 0.798655 |
SPLIT GNW COOLING COIL | 0.141589 | 2343.80 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.447039 | 7400.08 | 0.798655 |
SPLIT GNE COOLING COIL | 0.096121 | 1591.15 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.079148 | 1310.18 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.078044 | 1291.91 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.130406 | 2199.69 | 0.791802 |
SPLIT GS2 COOLING COIL | 0.133562 | 2242.82 | 0.793427 |
SPLIT MSW COOLING COIL | 0.491446 | 8135.17 | 0.798655 |
SPLIT MNW COOLING COIL | 0.391131 | 6474.61 | 0.798655 |
SPLIT MSE COOLING COIL | 0.456376 | 7554.64 | 0.798655 |
SPLIT MNE COOLING COIL | 0.291734 | 4829.24 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.231755 | 3836.37 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.229776 | 3803.61 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.370574 | 6134.31 | 0.798655 |
SPLIT MS2 COOLING COIL | 0.371832 | 6155.14 | 0.798655 |
SPLIT TSW COOLING COIL | 0.322556 | 5339.45 | 0.798655 |
SPLIT TNW COOLING COIL | 0.250659 | 4149.30 | 0.798655 |
SPLIT TSE COOLING COIL | 0.302387 | 5005.58 | 0.798655 |
SPLIT TNE COOLING COIL | 0.187338 | 3101.11 | 0.798655 |
SPLIT TN1 COOLING COIL | 0.148877 | 2480.99 | 0.796204 |
SPLIT TN2 COOLING COIL | 0.148548 | 2482.64 | 0.795156 |
SPLIT TS1 COOLING COIL | 0.260458 | 4311.50 | 0.798655 |
SPLIT TS2 COOLING COIL | 0.261282 | 4325.15 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.177225 | 0.177225 | 0.177225 | 0.177225 | 1948.11 | 2933.70 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.141589 | 0.141589 | 0.141589 | 0.141589 | 1926.74 | 2343.80 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.447039 | 0.447039 | 0.447039 | 0.447039 | 3758.68 | 7400.08 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.096121 | 0.096121 | 0.096121 | 0.096121 | 1931.71 | 1591.15 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.079148 | 0.079148 | 0.079148 | 0.079148 | 1677.79 | 1310.18 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.078044 | 0.078044 | 0.078044 | 0.078044 | 1677.79 | 1291.91 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.130406 | 0.130406 | 0.130406 | 0.130406 | 1677.79 | 2199.69 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.133562 | 0.133562 | 0.133562 | 0.133562 | 1677.79 | 2242.82 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.491446 | 0.491446 | 0.491446 | 0.491446 | 3796.14 | 8135.17 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.391131 | 0.391131 | 0.391131 | 0.391131 | 3819.21 | 6474.61 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.456376 | 0.456376 | 0.456376 | 0.456376 | 3809.50 | 7554.64 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.291734 | 0.291734 | 0.291734 | 0.291734 | 3832.56 | 4829.24 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.231755 | 0.231755 | 0.231755 | 0.231755 | 3355.59 | 3836.37 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.229776 | 0.229776 | 0.229776 | 0.229776 | 3355.59 | 3803.61 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.370574 | 0.370574 | 0.370574 | 0.370574 | 3355.59 | 6134.31 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.371832 | 0.371832 | 0.371832 | 0.371832 | 3355.59 | 6155.14 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.322556 | 0.322556 | 0.322556 | 0.322556 | 2977.80 | 5339.45 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.250659 | 0.250659 | 0.250659 | 0.250659 | 2991.27 | 4149.30 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.302387 | 0.302387 | 0.302387 | 0.302387 | 2984.71 | 5005.58 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.187338 | 0.187338 | 0.187338 | 0.187338 | 2998.18 | 3101.11 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.148877 | 0.148877 | 0.148877 | 0.148877 | 2317.43 | 2480.99 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.148548 | 0.148548 | 0.148548 | 0.148548 | 2317.63 | 2482.64 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.260458 | 0.260458 | 0.260458 | 0.260458 | 2301.88 | 4311.50 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.261282 | 0.261282 | 0.261282 | 0.261282 | 2302.08 | 4325.15 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.177225 |
SPLIT GNW SUPPLY FAN | 0.141589 |
SPLIT OFFICE SUPPLY FAN | 0.447039 |
SPLIT GNE SUPPLY FAN | 0.096121 |
SPLIT GN1 SUPPLY FAN | 0.079148 |
SPLIT GN2 SUPPLY FAN | 0.078044 |
SPLIT GS1 SUPPLY FAN | 0.130406 |
SPLIT GS2 SUPPLY FAN | 0.133562 |
SPLIT MSW SUPPLY FAN | 0.491446 |
SPLIT MNW SUPPLY FAN | 0.391131 |
SPLIT MSE SUPPLY FAN | 0.456376 |
SPLIT MNE SUPPLY FAN | 0.291734 |
SPLIT MN1 SUPPLY FAN | 0.231755 |
SPLIT MN2 SUPPLY FAN | 0.229776 |
SPLIT MS1 SUPPLY FAN | 0.370574 |
SPLIT MS2 SUPPLY FAN | 0.371832 |
SPLIT TSW SUPPLY FAN | 0.322556 |
SPLIT TNW SUPPLY FAN | 0.250659 |
SPLIT TSE SUPPLY FAN | 0.302387 |
SPLIT TNE SUPPLY FAN | 0.187338 |
SPLIT TN1 SUPPLY FAN | 0.148877 |
SPLIT TN2 SUPPLY FAN | 0.148548 |
SPLIT TS1 SUPPLY FAN | 0.260458 |
SPLIT TS2 SUPPLY FAN | 0.261282 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1948.11 |
SPLIT GNW HEATING COIL | 1926.74 |
SPLIT OFFICE HEATING COIL | 3758.68 |
SPLIT GNE HEATING COIL | 1931.71 |
SPLIT GN1 HEATING COIL | 1677.79 |
SPLIT GN2 HEATING COIL | 1677.79 |
SPLIT GS1 HEATING COIL | 1677.79 |
SPLIT GS2 HEATING COIL | 1677.79 |
SPLIT MSW HEATING COIL | 3796.14 |
SPLIT MNW HEATING COIL | 3819.21 |
SPLIT MSE HEATING COIL | 3809.50 |
SPLIT MNE HEATING COIL | 3832.56 |
SPLIT MN1 HEATING COIL | 3355.59 |
SPLIT MN2 HEATING COIL | 3355.59 |
SPLIT MS1 HEATING COIL | 3355.59 |
SPLIT MS2 HEATING COIL | 3355.59 |
SPLIT TSW HEATING COIL | 2977.80 |
SPLIT TNW HEATING COIL | 2991.27 |
SPLIT TSE HEATING COIL | 2984.71 |
SPLIT TNE HEATING COIL | 2998.18 |
SPLIT TN1 HEATING COIL | 2317.43 |
SPLIT TN2 HEATING COIL | 2317.63 |
SPLIT TS1 HEATING COIL | 2301.88 |
SPLIT TS2 HEATING COIL | 2302.08 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | 4.50 |
February | 21.88 | 5.82 |
March | 22.09 | 8.33 |
April | 22.52 | 10.85 |
May | 22.93 | 12.97 |
June | 24.06 | 15.59 |
July | 24.32 | 17.66 |
August | 24.33 | 18.80 |
September | 24.21 | 15.09 |
October | 22.65 | 11.43 |
November | 21.89 | 8.07 |
December | 21.76 | 5.42 |
Annual Sum or Average | 22.87 | 11.24 |
Minimum of Months | 21.72 | 4.50 |
Maximum of Months | 24.33 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.74 | 5.82 |
March | 21.81 | 8.33 |
April | 22.17 | 10.85 |
May | 22.64 | 12.97 |
June | 23.93 | 15.59 |
July | 24.27 | 17.66 |
August | 24.28 | 18.80 |
September | 24.04 | 15.09 |
October | 22.14 | 11.43 |
November | 21.77 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.69 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.28 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.10 | 4.50 |
February | 21.59 | 5.82 |
March | 22.39 | 8.33 |
April | 22.91 | 10.85 |
May | 23.31 | 12.97 |
June | 23.87 | 15.59 |
July | 23.90 | 17.66 |
August | 23.90 | 18.80 |
September | 23.89 | 15.09 |
October | 23.12 | 11.43 |
November | 22.10 | 8.07 |
December | 21.34 | 5.42 |
Annual Sum or Average | 22.79 | 11.24 |
Minimum of Months | 21.10 | 4.50 |
Maximum of Months | 23.90 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.72 | 5.82 |
March | 21.75 | 8.33 |
April | 22.11 | 10.85 |
May | 22.52 | 12.97 |
June | 23.89 | 15.59 |
July | 24.20 | 17.66 |
August | 24.25 | 18.80 |
September | 23.93 | 15.09 |
October | 22.04 | 11.43 |
November | 21.75 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.64 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.25 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.73 | 5.82 |
March | 21.77 | 8.33 |
April | 22.05 | 10.85 |
May | 22.42 | 12.97 |
June | 23.87 | 15.59 |
July | 24.23 | 17.66 |
August | 24.27 | 18.80 |
September | 24.00 | 15.09 |
October | 22.09 | 11.43 |
November | 21.77 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.64 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.27 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.73 | 5.82 |
March | 21.77 | 8.33 |
April | 22.04 | 10.85 |
May | 22.41 | 12.97 |
June | 23.87 | 15.59 |
July | 24.22 | 17.66 |
August | 24.26 | 18.80 |
September | 23.99 | 15.09 |
October | 22.09 | 11.43 |
November | 21.77 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.63 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.26 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | 4.50 |
February | 21.91 | 5.82 |
March | 22.12 | 8.33 |
April | 22.51 | 10.85 |
May | 22.86 | 12.97 |
June | 24.10 | 15.59 |
July | 24.33 | 17.66 |
August | 24.35 | 18.80 |
September | 24.26 | 15.09 |
October | 22.78 | 11.43 |
November | 21.96 | 8.07 |
December | 21.79 | 5.42 |
Annual Sum or Average | 22.90 | 11.24 |
Minimum of Months | 21.73 | 4.50 |
Maximum of Months | 24.35 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | 4.50 |
February | 21.92 | 5.82 |
March | 22.13 | 8.33 |
April | 22.53 | 10.85 |
May | 22.87 | 12.97 |
June | 24.10 | 15.59 |
July | 24.32 | 17.66 |
August | 24.35 | 18.80 |
September | 24.25 | 15.09 |
October | 22.79 | 11.43 |
November | 21.97 | 8.07 |
December | 21.79 | 5.42 |
Annual Sum or Average | 22.90 | 11.24 |
Minimum of Months | 21.73 | 4.50 |
Maximum of Months | 24.35 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | 4.50 |
February | 22.60 | 5.82 |
March | 23.65 | 8.33 |
April | 24.11 | 10.85 |
May | 24.32 | 12.97 |
June | 24.39 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.39 | 15.09 |
October | 24.17 | 11.43 |
November | 22.89 | 8.07 |
December | 22.13 | 5.42 |
Annual Sum or Average | 23.61 | 11.24 |
Minimum of Months | 21.86 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | 4.50 |
February | 22.01 | 5.82 |
March | 22.81 | 8.33 |
April | 23.75 | 10.85 |
May | 24.26 | 12.97 |
June | 24.38 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.38 | 15.09 |
October | 23.77 | 11.43 |
November | 22.34 | 8.07 |
December | 21.72 | 5.42 |
Annual Sum or Average | 23.33 | 11.24 |
Minimum of Months | 21.71 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | 4.50 |
February | 22.56 | 5.82 |
March | 23.64 | 8.33 |
April | 24.11 | 10.85 |
May | 24.31 | 12.97 |
June | 24.38 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.39 | 15.09 |
October | 24.14 | 11.43 |
November | 22.83 | 8.07 |
December | 22.10 | 5.42 |
Annual Sum or Average | 23.60 | 11.24 |
Minimum of Months | 21.84 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | 4.50 |
February | 21.94 | 5.82 |
March | 22.59 | 8.33 |
April | 23.69 | 10.85 |
May | 24.21 | 12.97 |
June | 24.37 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.36 | 15.09 |
October | 23.62 | 11.43 |
November | 22.23 | 8.07 |
December | 21.71 | 5.42 |
Annual Sum or Average | 23.28 | 11.24 |
Minimum of Months | 21.71 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | 4.50 |
February | 22.09 | 5.82 |
March | 23.08 | 8.33 |
April | 23.93 | 10.85 |
May | 24.32 | 12.97 |
June | 24.39 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.39 | 15.09 |
October | 24.02 | 11.43 |
November | 22.57 | 8.07 |
December | 21.76 | 5.42 |
Annual Sum or Average | 23.43 | 11.24 |
Minimum of Months | 21.75 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | 4.50 |
February | 22.09 | 5.82 |
March | 23.05 | 8.33 |
April | 23.93 | 10.85 |
May | 24.32 | 12.97 |
June | 24.39 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.39 | 15.09 |
October | 24.01 | 11.43 |
November | 22.56 | 8.07 |
December | 21.76 | 5.42 |
Annual Sum or Average | 23.43 | 11.24 |
Minimum of Months | 21.75 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 4.50 |
February | 23.00 | 5.82 |
March | 24.03 | 8.33 |
April | 24.27 | 10.85 |
May | 24.37 | 12.97 |
June | 24.40 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.40 | 15.09 |
October | 24.33 | 11.43 |
November | 23.43 | 8.07 |
December | 22.50 | 5.42 |
Annual Sum or Average | 23.81 | 11.24 |
Minimum of Months | 22.10 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 4.50 |
February | 23.00 | 5.82 |
March | 24.03 | 8.33 |
April | 24.27 | 10.85 |
May | 24.37 | 12.97 |
June | 24.40 | 15.59 |
July | 24.40 | 17.66 |
August | 24.40 | 18.80 |
September | 24.40 | 15.09 |
October | 24.33 | 11.43 |
November | 23.42 | 8.07 |
December | 22.50 | 5.42 |
Annual Sum or Average | 23.80 | 11.24 |
Minimum of Months | 22.10 | 4.50 |
Maximum of Months | 24.40 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | 4.50 |
February | 22.20 | 5.82 |
March | 22.67 | 8.33 |
April | 23.29 | 10.85 |
May | 23.81 | 12.97 |
June | 24.21 | 15.59 |
July | 24.37 | 17.66 |
August | 24.36 | 18.80 |
September | 24.21 | 15.09 |
October | 23.14 | 11.43 |
November | 22.18 | 8.07 |
December | 21.89 | 5.42 |
Annual Sum or Average | 23.18 | 11.24 |
Minimum of Months | 21.77 | 4.50 |
Maximum of Months | 24.37 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.86 | 5.82 |
March | 22.19 | 8.33 |
April | 22.92 | 10.85 |
May | 23.62 | 12.97 |
June | 24.12 | 15.59 |
July | 24.33 | 17.66 |
August | 24.31 | 18.80 |
September | 24.01 | 15.09 |
October | 22.60 | 11.43 |
November | 21.91 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.95 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.33 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | 4.50 |
February | 22.18 | 5.82 |
March | 22.66 | 8.33 |
April | 23.31 | 10.85 |
May | 23.79 | 12.97 |
June | 24.19 | 15.59 |
July | 24.35 | 17.66 |
August | 24.35 | 18.80 |
September | 24.18 | 15.09 |
October | 23.12 | 11.43 |
November | 22.16 | 8.07 |
December | 21.88 | 5.42 |
Annual Sum or Average | 23.17 | 11.24 |
Minimum of Months | 21.76 | 4.50 |
Maximum of Months | 24.35 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.82 | 5.82 |
March | 22.07 | 8.33 |
April | 22.89 | 10.85 |
May | 23.53 | 12.97 |
June | 24.05 | 15.59 |
July | 24.27 | 17.66 |
August | 24.27 | 18.80 |
September | 23.89 | 15.09 |
October | 22.48 | 11.43 |
November | 21.87 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.88 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.27 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.86 | 5.82 |
March | 22.14 | 8.33 |
April | 22.93 | 10.85 |
May | 23.67 | 12.97 |
June | 24.15 | 15.59 |
July | 24.33 | 17.66 |
August | 24.32 | 18.80 |
September | 24.01 | 15.09 |
October | 22.59 | 11.43 |
November | 21.93 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.95 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.33 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 4.50 |
February | 21.86 | 5.82 |
March | 22.14 | 8.33 |
April | 22.93 | 10.85 |
May | 23.66 | 12.97 |
June | 24.15 | 15.59 |
July | 24.33 | 17.66 |
August | 24.32 | 18.80 |
September | 24.00 | 15.09 |
October | 22.59 | 11.43 |
November | 21.93 | 8.07 |
December | 21.70 | 5.42 |
Annual Sum or Average | 22.95 | 11.24 |
Minimum of Months | 21.70 | 4.50 |
Maximum of Months | 24.33 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | 4.50 |
February | 22.33 | 5.82 |
March | 22.83 | 8.33 |
April | 23.48 | 10.85 |
May | 23.96 | 12.97 |
June | 24.28 | 15.59 |
July | 24.39 | 17.66 |
August | 24.38 | 18.80 |
September | 24.28 | 15.09 |
October | 23.38 | 11.43 |
November | 22.32 | 8.07 |
December | 21.95 | 5.42 |
Annual Sum or Average | 23.29 | 11.24 |
Minimum of Months | 21.80 | 4.50 |
Maximum of Months | 24.39 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | 4.50 |
February | 22.33 | 5.82 |
March | 22.83 | 8.33 |
April | 23.48 | 10.85 |
May | 23.95 | 12.97 |
June | 24.28 | 15.59 |
July | 24.39 | 17.66 |
August | 24.38 | 18.80 |
September | 24.28 | 15.09 |
October | 23.38 | 11.43 |
November | 22.33 | 8.07 |
December | 21.95 | 5.42 |
Annual Sum or Average | 23.29 | 11.24 |
Minimum of Months | 21.80 | 4.50 |
Maximum of Months | 24.39 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | 4.50 |
February | 22.32 | 5.82 |
March | 23.19 | 8.33 |
April | 24.34 | 10.85 |
May | 25.29 | 12.97 |
June | 25.99 | 15.59 |
July | 26.39 | 17.66 |
August | 26.39 | 18.80 |
September | 25.67 | 15.09 |
October | 23.92 | 11.43 |
November | 22.52 | 8.07 |
December | 21.87 | 5.42 |
Annual Sum or Average | 24.15 | 11.24 |
Minimum of Months | 21.73 | 4.50 |
Maximum of Months | 26.39 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.46 | 4.50 |
February | 20.86 | 5.82 |
March | 21.49 | 8.33 |
April | 22.23 | 10.85 |
May | 22.88 | 12.97 |
June | 24.69 | 15.59 |
July | 25.36 | 17.66 |
August | 25.57 | 18.80 |
September | 24.82 | 15.09 |
October | 22.52 | 11.43 |
November | 21.30 | 8.07 |
December | 20.68 | 5.42 |
Annual Sum or Average | 22.75 | 11.24 |
Minimum of Months | 20.46 | 4.50 |
Maximum of Months | 25.57 | 18.80 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.34 | 4.50 |
February | 24.01 | 5.82 |
March | 25.23 | 8.33 |
April | 26.02 | 10.85 |
May | 26.52 | 12.97 |
June | 26.72 | 15.59 |
July | 26.85 | 17.66 |
August | 26.86 | 18.80 |
September | 26.65 | 15.09 |
October | 26.02 | 11.43 |
November | 24.50 | 8.07 |
December | 23.55 | 5.42 |
Annual Sum or Average | 25.53 | 11.24 |
Minimum of Months | 23.34 | 4.50 |
Maximum of Months | 26.86 | 18.80 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.116367E+12 | 76339.207 | 04-JAN-18:15 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32081.193 | 0.000 | 0.000 | 0.000 |
February | 0.105279E+12 | 73698.125 | 05-FEB-18:30 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 29440.112 | 0.000 | 0.000 | 0.000 |
March | 0.116490E+12 | 71490.302 | 02-MAR-18:00 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 1923.619 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25308.670 | 0.000 | 0.000 | 0.000 |
April | 0.113880E+12 | 78677.416 | 27-APR-17:15 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 13210.104 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23717.629 | 0.000 | 0.000 | 0.000 |
May | 0.119060E+12 | 76022.132 | 05-MAY-17:15 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 9895.824 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24376.625 | 0.000 | 0.000 | 0.000 |
June | 0.117158E+12 | 78250.378 | 20-JUN-17:45 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 12967.239 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23533.456 | 0.000 | 0.000 | 0.000 |
July | 0.124882E+12 | 80854.274 | 31-JUL-17:15 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 16764.774 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22339.817 | 0.000 | 0.000 | 0.000 |
August | 0.126809E+12 | 83445.562 | 10-AUG-17:30 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 18773.167 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22922.712 | 0.000 | 0.000 | 0.000 |
September | 0.117259E+12 | 78856.847 | 11-SEP-17:30 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 11650.044 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25457.120 | 0.000 | 0.000 | 0.000 |
October | 0.115625E+12 | 70910.963 | 04-OCT-17:30 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 6880.049 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22281.231 | 0.000 | 0.000 | 0.000 |
November | 0.111141E+12 | 70252.999 | 04-NOV-17:30 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 3917.933 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22077.052 | 0.000 | 0.000 | 0.000 |
December | 0.115728E+12 | 70606.899 | 27-DEC-18:15 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26348.886 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.139968E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.105279E+12 | 70252.999 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22077.052 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.126809E+12 | 83445.562 | 8572.775 | 26456.413 | 6720.496 | 0.000 | 18773.167 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32081.193 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.441000E+11 | 43434.379 | 15-JAN-04:00 | 43434.379 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 43434.379 |
February | 0.283990E+11 | 52217.547 | 19-FEB-05:00 | 52217.547 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 52217.547 |
March | 0.110478E+11 | 21006.184 | 05-MAR-03:00 | 21006.184 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21006.184 |
April | 0.440410E+10 | 14727.463 | 11-APR-03:00 | 14727.463 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14727.463 |
May | 0.105648E+10 | 10220.557 | 18-MAY-04:00 | 10220.557 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10220.557 |
June | 5302928.428 | 425.969 | 14-JUN-03:15 | 425.969 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 425.969 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.144046E+08 | 888.241 | 27-SEP-03:00 | 888.241 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 888.241 |
October | 0.310133E+10 | 10578.747 | 28-OCT-03:00 | 10578.747 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10578.747 |
November | 0.182453E+11 | 28575.354 | 30-NOV-00:00 | 28575.354 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28575.354 |
December | 0.365864E+11 | 39292.522 | 26-DEC-03:00 | 39292.522 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 39292.522 |
Annual Sum or Average | 0.146960E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.441000E+11 | 52217.547 | 52217.547 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 52217.547 |