Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820
Simulation Timestamp: 2018-10-19 09:20:30
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1724.94 | 550.29 | 610.82 |
Net Site Energy | 1724.94 | 550.29 | 610.82 |
Total Source Energy | 5455.11 | 1740.28 | 1931.71 |
Net Source Energy | 5455.11 | 1740.28 | 1931.71 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 3.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 421.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 287.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 296.75 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1721.20 | 3.74 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 3.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 421.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 287.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 296.75 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 356.00 | 1.32 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 609.50 | 1.32 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 320.72 | 1.19 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 549.10 | 1.19 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1721.20 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1721.20 | 100.00 |
Total On-Site and Utility Electric Sources | 1721.20 | 100.00 |
Total Electricity End Uses | 1721.20 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 7.75 |
Time Setpoint Not Met During Occupied Cooling | 1.75 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1524.25 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Weather File | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Latitude [deg] | 28.58 |
Longitude [deg] | 77.20 |
Elevation [m] | 216.00 |
Time Zone | 5.50 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 02-JUL-17:30 | 03-JAN-06:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 9905.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 35966.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 9108.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 15912.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 96017.22 | 9905.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 9905.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 35966.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 9108.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 15912.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 4.05 | 0.00 | 0.00 | 0.00 |
Cooling | 1334.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 909.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 939.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 5451.05 | 4.05 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 1.44 | 0.00 | 0.00 | 0.00 |
Cooling | 472.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 322.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 332.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1930.28 | 1.44 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 1.44 | 0.00 | 0.00 | 0.00 |
Cooling | 472.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 322.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 332.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1930.28 | 1.44 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 6.30 | 0.00 | 6.30 | Wetbulb [C] | 0.50 | 270.00 |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 42.00 | 9.70 | 22.20 | Wetbulb [C] | 3.20 | 320.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.55 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_1.22_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 5.778 | 0.306 | 0.155 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 5.778 | 0.306 | 0.155 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 5.778 | 0.306 | 0.155 | ||||||||||||
North Total or Average | 112.97 | 5.778 | 0.306 | 0.155 | ||||||||||||
Non-North Total or Average | 193.95 | 5.778 | 0.306 | 0.155 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.76 | 83.76 | 39.44 | |
Exterior Lighting Total | 2508.33 | 39.44 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4787.41 | 3548.88 | 1238.53 | 0.74 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4827.14 | 3586.73 | 1240.41 | 0.74 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8586.16 | 6752.13 | 1834.03 | 0.79 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4138.71 | 3065.55 | 1073.16 | 0.74 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3225.69 | 2360.12 | 865.57 | 0.73 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3216.07 | 2352.54 | 863.53 | 0.73 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3110.44 | 2269.47 | 840.97 | 0.73 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3089.66 | 2266.79 | 822.87 | 0.73 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11406.94 | 8543.32 | 2863.61 | 0.75 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11506.03 | 8635.70 | 2870.33 | 0.75 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10449.59 | 7708.13 | 2741.47 | 0.74 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10168.75 | 7599.12 | 2569.62 | 0.75 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7801.55 | 5781.99 | 2019.56 | 0.74 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7786.21 | 5769.89 | 2016.32 | 0.74 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7527.09 | 5565.66 | 1961.43 | 0.74 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7511.93 | 5553.71 | 1958.23 | 0.74 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7165.97 | 5399.39 | 1766.58 | 0.75 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7178.43 | 5417.87 | 1760.56 | 0.75 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6661.12 | 4969.13 | 1691.99 | 0.75 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6508.76 | 4857.01 | 1651.75 | 0.75 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5082.05 | 3785.85 | 1296.21 | 0.74 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5066.30 | 3773.49 | 1292.81 | 0.74 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5213.79 | 3847.13 | 1366.66 | 0.74 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5216.14 | 3848.97 | 1367.18 | 0.74 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4595.7 | 3.23 | 11.02 | 11.46 | 10.88 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4632.7 | 3.23 | 11.01 | 11.45 | 10.86 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8193.0 | 3.15 | 10.74 | 11.17 | 10.48 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3973.2 | 3.23 | 11.02 | 11.47 | 10.89 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3100.4 | 3.25 | 11.08 | 11.53 | 10.97 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3091.3 | 3.25 | 11.08 | 11.53 | 10.97 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2990.5 | 3.25 | 11.09 | 11.54 | 10.99 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2968.9 | 3.24 | 11.06 | 11.52 | 10.95 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10938.9 | 3.21 | 10.97 | 11.41 | 10.81 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11031.7 | 3.21 | 10.96 | 11.40 | 10.80 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10035.9 | 3.24 | 11.04 | 11.49 | 10.91 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9753.7 | 3.22 | 10.98 | 11.42 | 10.83 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7489.2 | 3.23 | 11.02 | 11.46 | 10.88 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7474.6 | 3.23 | 11.02 | 11.47 | 10.88 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7227.4 | 3.23 | 11.03 | 11.48 | 10.90 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7212.9 | 3.23 | 11.03 | 11.48 | 10.90 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6867.9 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6878.6 | 3.20 | 10.93 | 11.37 | 10.76 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6390.3 | 3.22 | 10.99 | 11.43 | 10.84 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6244.0 | 3.22 | 10.99 | 11.43 | 10.84 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4876.1 | 3.22 | 10.99 | 11.44 | 10.85 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4861.1 | 3.22 | 10.99 | 11.44 | 10.85 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5007.2 | 3.23 | 11.04 | 11.49 | 10.91 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5009.5 | 3.23 | 11.04 | 11.49 | 10.91 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1386.44 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 2768.38 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1337.71 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2675.42 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 1908.62 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 1909.49 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 1903.43 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 1904.30 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 1424.96 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 1424.81 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 1422.53 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 1422.38 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 273.40 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 277.22 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.50 | 561.62 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 235.90 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.16 | 178.50 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.16 | 177.87 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 170.95 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 172.11 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.60 | 667.53 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.60 | 676.67 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.53 | 589.75 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.53 | 591.97 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 445.30 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 444.30 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 427.26 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 426.26 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 425.30 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 427.72 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 386.17 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 377.61 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 293.64 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 292.62 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 294.47 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 294.62 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2531.92 | 3038.31 | 0.203 | 0.244 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:45:00 | 40.84 | 0.00911 |
G NW APARTMENT | 2567.25 | 3080.70 | 0.206 | 0.247 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:45:00 | 40.84 | 0.00911 |
OFFICE | 5089.97 | 6107.97 | 0.418 | 0.501 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | 36.66 | 0.00911 |
G NE APARTMENT | 2184.68 | 2621.61 | 0.176 | 0.211 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 17:30:00 | 40.16 | 0.00911 |
G N1 APARTMENT | 1653.04 | 1983.64 | 0.133 | 0.159 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
G N2 APARTMENT | 1647.19 | 1976.63 | 0.132 | 0.159 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
G S1 APARTMENT | 1583.20 | 1899.83 | 0.127 | 0.153 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
G S2 APARTMENT | 1593.89 | 1912.67 | 0.128 | 0.154 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:30:00 | 38.94 | 0.00911 |
M SW APARTMENT | 6181.82 | 7418.19 | 0.497 | 0.596 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:45:00 | 40.84 | 0.00911 |
M NW APARTMENT | 6266.47 | 7519.77 | 0.503 | 0.604 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 17:00:00 | 40.64 | 0.00911 |
M SE APARTMENT | 5461.56 | 6553.88 | 0.439 | 0.527 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:15:00 | 42.00 | 0.00911 |
M NE APARTMENT | 5482.10 | 6578.53 | 0.440 | 0.528 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 17:15:00 | 40.40 | 0.00911 |
M N1 APARTMENT | 4123.92 | 4948.70 | 0.331 | 0.398 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
M N2 APARTMENT | 4114.57 | 4937.48 | 0.331 | 0.397 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
M S1 APARTMENT | 3956.82 | 4748.18 | 0.318 | 0.381 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
M S2 APARTMENT | 3947.58 | 4737.10 | 0.317 | 0.381 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 18:00:00 | 39.67 | 0.00911 |
T SW APARTMENT | 3938.65 | 4726.38 | 0.316 | 0.380 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:15:00 | 41.22 | 0.00911 |
T NW APARTMENT | 3961.00 | 4753.20 | 0.318 | 0.382 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:30:00 | 41.03 | 0.00911 |
T SE APARTMENT | 3576.18 | 4291.42 | 0.287 | 0.345 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:15:00 | 42.00 | 0.00911 |
T NE APARTMENT | 3496.99 | 4196.39 | 0.281 | 0.337 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:15:00 | 41.85 | 0.00911 |
T N1 APARTMENT | 2719.37 | 3263.25 | 0.218 | 0.262 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:45:00 | 40.84 | 0.00911 |
T N2 APARTMENT | 2709.89 | 3251.87 | 0.218 | 0.261 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:45:00 | 40.84 | 0.00911 |
T S1 APARTMENT | 2727.05 | 3272.46 | 0.219 | 0.263 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:30:00 | 42.00 | 0.00911 |
T S2 APARTMENT | 2728.45 | 3274.14 | 0.219 | 0.263 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:30:00 | 42.00 | 0.00911 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 704.84 | 845.81 | 0.021 | 0.027 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
G NW APARTMENT | 703.15 | 843.78 | 0.021 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
OFFICE | 1812.01 | 2174.41 | 0.051 | 0.061 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 6.30 | 0.00607 |
G NE APARTMENT | 700.18 | 840.22 | 0.021 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
G N1 APARTMENT | 355.80 | 426.96 | 0.011 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
G N2 APARTMENT | 355.72 | 426.87 | 0.011 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
G S1 APARTMENT | 358.40 | 430.07 | 0.011 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
G S2 APARTMENT | 421.09 | 505.31 | 0.012 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M SW APARTMENT | 1344.20 | 1613.04 | 0.040 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M NW APARTMENT | 1345.04 | 1614.05 | 0.040 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M SE APARTMENT | 1335.85 | 1603.02 | 0.039 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M NE APARTMENT | 1336.72 | 1604.07 | 0.039 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M N1 APARTMENT | 454.06 | 544.88 | 0.013 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M N2 APARTMENT | 453.81 | 544.57 | 0.013 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M S1 APARTMENT | 453.03 | 543.63 | 0.013 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
M S2 APARTMENT | 452.77 | 543.32 | 0.013 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T SW APARTMENT | 1215.36 | 1458.44 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T NW APARTMENT | 1216.10 | 1459.31 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T SE APARTMENT | 1210.97 | 1453.17 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T NE APARTMENT | 1211.70 | 1454.04 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T N1 APARTMENT | 806.35 | 967.62 | 0.024 | 0.029 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T N2 APARTMENT | 806.23 | 967.47 | 0.024 | 0.029 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T S1 APARTMENT | 804.29 | 965.15 | 0.024 | 0.028 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
T S2 APARTMENT | 804.17 | 965.00 | 0.024 | 0.028 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30 | 0.00607 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.24 | 0.24 | 0.03 | 0.03 |
SPLIT GNW | 0.25 | 0.25 | 0.03 | 0.03 |
SPLIT OFFICE | 0.50 | 0.50 | 0.06 | 0.06 |
SPLIT GNE | 0.21 | 0.21 | 0.03 | 0.03 |
SPLIT GN1 | 0.16 | 0.16 | 0.03 | 0.03 |
SPLIT GN2 | 0.16 | 0.16 | 0.03 | 0.03 |
SPLIT GS1 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT GS2 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT MSW | 0.60 | 0.60 | 0.05 | 0.05 |
SPLIT MNW | 0.60 | 0.60 | 0.05 | 0.05 |
SPLIT MSE | 0.53 | 0.53 | 0.05 | 0.05 |
SPLIT MNE | 0.53 | 0.53 | 0.05 | 0.05 |
SPLIT MN1 | 0.40 | 0.40 | 0.05 | 0.05 |
SPLIT MN2 | 0.40 | 0.40 | 0.05 | 0.05 |
SPLIT MS1 | 0.38 | 0.38 | 0.05 | 0.05 |
SPLIT MS2 | 0.38 | 0.38 | 0.05 | 0.05 |
SPLIT TSW | 0.38 | 0.38 | 0.04 | 0.04 |
SPLIT TNW | 0.38 | 0.38 | 0.04 | 0.04 |
SPLIT TSE | 0.34 | 0.34 | 0.04 | 0.04 |
SPLIT TNE | 0.34 | 0.34 | 0.04 | 0.04 |
SPLIT TN1 | 0.26 | 0.26 | 0.03 | 0.03 |
SPLIT TN2 | 0.26 | 0.26 | 0.03 | 0.03 |
SPLIT TS1 | 0.26 | 0.26 | 0.03 | 0.03 |
SPLIT TS2 | 0.26 | 0.26 | 0.03 | 0.03 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 5195.50 | 3308.25 | 1149.75 |
G NW APARTMENT | 4655.50 | 4061.75 | 1161.75 |
OFFICE | 1420.00 | 470.25 | 25.50 |
G NE APARTMENT | 4676.00 | 4080.00 | 1164.50 |
G N1 APARTMENT | 4329.75 | 4615.25 | 1518.75 |
G N2 APARTMENT | 4329.50 | 4615.25 | 1516.75 |
G S1 APARTMENT | 4892.75 | 3579.25 | 1372.00 |
G S2 APARTMENT | 5022.50 | 3376.75 | 1218.00 |
M SW APARTMENT | 6984.25 | 910.00 | 531.50 |
M NW APARTMENT | 6160.00 | 1561.25 | 554.25 |
M SE APARTMENT | 6982.00 | 857.75 | 462.25 |
M NE APARTMENT | 6187.00 | 1555.00 | 555.25 |
M N1 APARTMENT | 6138.75 | 1449.25 | 710.50 |
M N2 APARTMENT | 6140.25 | 1451.50 | 711.25 |
M S1 APARTMENT | 7207.00 | 816.50 | 653.75 |
M S2 APARTMENT | 7206.25 | 817.50 | 653.50 |
T SW APARTMENT | 6400.00 | 1932.75 | 672.75 |
T NW APARTMENT | 5814.50 | 2476.00 | 695.25 |
T SE APARTMENT | 6419.00 | 1905.00 | 647.00 |
T NE APARTMENT | 5823.75 | 2460.50 | 671.00 |
T N1 APARTMENT | 5808.75 | 2467.00 | 785.75 |
T N2 APARTMENT | 5807.25 | 2469.50 | 786.25 |
T S1 APARTMENT | 6501.00 | 1734.25 | 698.75 |
T S2 APARTMENT | 6502.50 | 1737.25 | 699.50 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 7346.25 | 4643.00 | 1524.25 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
G NW APARTMENT | 0.00 | 0.75 | 0.00 | 0.75 |
OFFICE | 0.00 | 49.75 | 0.00 | 0.00 |
G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G N1 APARTMENT | 5.25 | 0.00 | 5.25 | 0.00 |
G N2 APARTMENT | 5.00 | 0.25 | 5.00 | 0.25 |
G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 0.00 | 0.75 | 0.00 | 0.75 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 7.75 | 51.50 | 7.75 | 1.75 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.372 | 0.036 | 0.000 | 0.060 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.036 | 0.000 | 0.057 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.526 | 0.051 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.036 | 0.000 | 0.057 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.022 | 0.000 | 0.056 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.022 | 0.000 | 0.056 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.022 | 0.000 | 0.060 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.022 | 0.000 | 0.060 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.051 | 0.000 | 0.066 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.051 | 0.000 | 0.065 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.051 | 0.000 | 0.066 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.051 | 0.000 | 0.065 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.031 | 0.000 | 0.065 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.031 | 0.000 | 0.065 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.031 | 0.000 | 0.066 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.031 | 0.000 | 0.066 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.068 | 0.000 | 0.072 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.068 | 0.000 | 0.070 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.068 | 0.000 | 0.072 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.068 | 0.000 | 0.070 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.041 | 0.000 | 0.070 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.041 | 0.000 | 0.070 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.041 | 0.000 | 0.072 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.041 | 0.000 | 0.072 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.508 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.328 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.321 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.316 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.321 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.318 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.318 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.318 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.321 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.321 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.328 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.328 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 296.75 | 0.00 | 01-JAN-00:15 | 29647.28 | 01-JAN-06:15 |
WaterSystems:Electricity | 296.75 | 0.00 | 01-JAN-00:15 | 29647.28 | 01-JAN-06:15 |
Water Heater:WaterSystems:Electricity | 296.75 | 0.00 | 01-JAN-00:15 | 29647.28 | 01-JAN-06:15 |
Fans:Electricity | 287.25 | 9108.76 | 15-JAN-21:45 | 9108.76 | 01-JAN-18:30 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
ElectricityPurchased:Plant | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
Cogeneration:ElectricityPurchased | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
ElectricityNet:Plant | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
Cogeneration:ElectricityNet | 1721.20 | 22479.06 | 01-JAN-03:15 | 96017.22 | 02-JUL-17:30 |
ExteriorLights:Electricity | 39.44 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.44 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 708.59 | 9108.76 | 01-JAN-08:30 | 46714.02 | 10-JUN-16:15 |
General:Fans:Electricity | 287.25 | 9108.76 | 15-JAN-21:45 | 9108.76 | 01-JAN-18:30 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 421.34 | 0.00 | 01-JAN-00:15 | 37605.26 | 10-JUN-16:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 3.74 | 0.00 | 01-JAN-11:15 | 9905.98 | 03-JAN-07:00 |
Gas:HVAC | 3.74 | 0.00 | 01-JAN-11:15 | 9905.98 | 03-JAN-07:00 |
Heating:Gas | 3.74 | 0.00 | 01-JAN-11:15 | 9905.98 | 03-JAN-07:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 2605.60 | 1669.70 | 10-FEB-15:00 | 210547.25 | 06-JUN-15:15 |
EnergyTransfer:Building | 989.45 | 1669.70 | 10-FEB-15:00 | 90737.52 | 06-JUN-15:15 |
EnergyTransfer:Zone:G SW APARTMENT | 23.87 | 0.01 | 10-FEB-11:15 | 3038.43 | 06-JUN-16:15 |
Heating:EnergyTransfer | 12.89 | 0.00 | 20-FEB-15:15 | 5005.58 | 02-JAN-05:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.16 | 0.00 | 01-JAN-08:00 | 214.69 | 02-JAN-05:00 |
Cooling:EnergyTransfer | 976.56 | 136.34 | 29-DEC-06:30 | 90737.52 | 06-JUN-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 23.71 | 0.00 | 01-JAN-00:15 | 3038.43 | 06-JUN-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 19.86 | 0.03 | 29-JAN-19:15 | 3050.87 | 06-JUN-16:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.72 | 0.00 | 01-JAN-10:45 | 352.93 | 02-JAN-04:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 19.13 | 0.00 | 01-JAN-00:15 | 3050.87 | 06-JUN-16:30 |
EnergyTransfer:Zone:OFFICE | 34.63 | 0.03 | 06-DEC-01:45 | 4836.39 | 12-JUN-09:45 |
Heating:EnergyTransfer:Zone:OFFICE | 7.11 | 0.00 | 01-JAN-00:15 | 996.69 | 02-MAY-17:30 |
Cooling:EnergyTransfer:Zone:OFFICE | 27.52 | 0.00 | 01-JAN-11:30 | 4836.39 | 12-JUN-09:45 |
EnergyTransfer:Zone:G NE APARTMENT | 19.61 | 0.01 | 17-OCT-04:00 | 2459.05 | 12-JUN-17:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.51 | 0.00 | 01-JAN-09:30 | 378.42 | 02-JAN-04:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 19.10 | 0.00 | 01-JAN-00:15 | 2459.05 | 12-JUN-17:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 14.40 | 0.00 | 19-JAN-11:15 | 1869.04 | 12-JUN-17:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.26 | 0.00 | 01-JAN-06:15 | 270.05 | 21-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 14.14 | 0.00 | 01-JAN-00:15 | 1869.04 | 12-JUN-17:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 14.40 | 0.00 | 16-DEC-08:00 | 1859.78 | 12-JUN-17:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.26 | 0.00 | 01-JAN-06:15 | 254.88 | 23-DEC-02:15 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 14.14 | 0.00 | 01-JAN-00:15 | 1859.78 | 12-JUN-17:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 18.74 | 0.08 | 18-MAR-24:00 | 1894.43 | 27-SEP-14:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 81.90 | 19-FEB-24:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 18.74 | 0.00 | 02-JAN-16:00 | 1894.43 | 27-SEP-14:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 19.75 | 0.01 | 25-FEB-00:45 | 1919.42 | 22-SEP-14:15 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 69.89 | 01-FEB-15:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 19.74 | 0.00 | 02-JAN-16:00 | 1919.42 | 22-SEP-14:15 |
EnergyTransfer:Zone:M SW APARTMENT | 81.48 | 1.39 | 12-JAN-03:15 | 7361.48 | 05-MAY-16:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.02 | 0.00 | 01-JAN-00:15 | 266.45 | 29-DEC-18:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 81.46 | 0.00 | 12-JAN-03:15 | 7361.48 | 05-MAY-16:15 |
EnergyTransfer:Zone:M NW APARTMENT | 65.71 | 0.12 | 16-DEC-03:15 | 7323.18 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.17 | 0.00 | 01-JAN-00:15 | 428.40 | 24-DEC-12:30 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 65.53 | 0.00 | 01-JAN-12:00 | 7323.18 | 06-JUN-16:15 |
EnergyTransfer:Zone:M SE APARTMENT | 81.78 | 1.46 | 29-DEC-23:45 | 6130.89 | 15-APR-14:15 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 225.69 | 29-DEC-17:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 81.77 | 0.00 | 15-JAN-09:30 | 6130.89 | 15-APR-14:15 |
EnergyTransfer:Zone:M NE APARTMENT | 65.80 | 0.13 | 11-JAN-13:00 | 6036.36 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.08 | 0.00 | 01-JAN-00:15 | 379.38 | 04-JAN-14:15 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 65.72 | 0.00 | 01-JAN-12:30 | 6036.36 | 06-JUN-16:15 |
EnergyTransfer:Zone:M N1 APARTMENT | 53.41 | 0.09 | 03-FEB-10:30 | 4471.37 | 12-JUN-17:15 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.02 | 0.00 | 01-JAN-00:15 | 221.64 | 04-JAN-13:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 53.40 | 0.00 | 01-JAN-13:30 | 4471.37 | 12-JUN-17:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 53.43 | 0.27 | 22-JAN-11:45 | 4456.69 | 12-JUN-17:15 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 221.57 | 04-JAN-13:45 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 53.41 | 0.00 | 01-JAN-13:30 | 4456.69 | 12-JUN-17:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 70.03 | 39.08 | 09-FEB-13:30 | 4942.37 | 17-OCT-14:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 70.03 | 39.08 | 09-FEB-13:30 | 4942.37 | 17-OCT-14:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 70.04 | 39.81 | 09-FEB-13:30 | 4943.47 | 17-OCT-14:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 70.04 | 39.81 | 09-FEB-13:30 | 4943.47 | 17-OCT-14:15 |
EnergyTransfer:Zone:T SW APARTMENT | 42.15 | 0.02 | 30-DEC-20:30 | 4681.62 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.59 | 0.00 | 01-JAN-10:00 | 593.90 | 03-JAN-07:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 41.56 | 0.00 | 01-JAN-00:15 | 4681.62 | 06-JUN-16:15 |
EnergyTransfer:Zone:T NW APARTMENT | 35.70 | 0.01 | 12-JAN-12:15 | 4700.77 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 1.12 | 0.00 | 03-JAN-14:45 | 732.25 | 03-JAN-07:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 34.58 | 0.00 | 01-JAN-00:15 | 4700.77 | 06-JUN-16:15 |
EnergyTransfer:Zone:T SE APARTMENT | 41.98 | 0.04 | 04-JAN-01:15 | 4007.39 | 15-APR-14:15 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.44 | 0.00 | 01-JAN-09:00 | 603.20 | 03-JAN-07:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 41.55 | 0.00 | 01-JAN-00:15 | 4007.39 | 15-APR-14:15 |
EnergyTransfer:Zone:T NE APARTMENT | 35.22 | 0.07 | 02-DEC-02:00 | 3898.05 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.83 | 0.00 | 01-JAN-10:30 | 761.05 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 34.39 | 0.00 | 01-JAN-00:15 | 3898.05 | 06-JUN-16:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 28.26 | 0.03 | 01-NOV-03:00 | 3077.62 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.25 | 0.00 | 01-JAN-10:15 | 400.92 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 28.01 | 0.00 | 01-JAN-00:15 | 3077.62 | 06-JUN-16:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 28.26 | 0.00 | 31-DEC-02:30 | 3062.96 | 06-JUN-16:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.24 | 0.00 | 01-JAN-10:15 | 406.11 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 28.02 | 0.00 | 01-JAN-00:15 | 3062.96 | 06-JUN-16:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 35.47 | 0.01 | 14-JAN-06:00 | 3201.73 | 02-OCT-14:15 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 213.32 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 35.43 | 0.00 | 01-JAN-02:15 | 3201.73 | 02-OCT-14:15 |
EnergyTransfer:Zone:T S2 APARTMENT | 35.49 | 0.02 | 18-JAN-04:00 | 3206.41 | 02-OCT-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 215.03 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 35.44 | 0.00 | 01-JAN-02:15 | 3206.41 | 02-OCT-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 1616.15 | 0.00 | 15-JAN-13:15 | 135126.67 | 01-JUL-16:15 |
HeatingCoils:EnergyTransfer | 2.99 | 0.00 | 01-JAN-11:15 | 7924.78 | 03-JAN-07:00 |
CoolingCoils:EnergyTransfer | 1613.15 | 0.00 | 01-JAN-00:15 | 135126.67 | 01-JUL-16:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.162 | -23.710 | 0.000 | 0.000 | 3.596 | 2.413 | 12.213 | 19.256 | 0.000 | 0.506 | 0.000 | 0.000 | -3.770 | 0.000 | -0.841 | -9.825 |
G NW APARTMENT | 0.721 | -19.135 | 0.000 | 0.000 | 3.622 | 2.413 | 12.213 | 13.005 | 0.000 | 0.505 | 0.000 | 0.000 | -3.755 | 0.000 | -0.733 | -8.857 |
OFFICE | 7.111 | -27.518 | 0.000 | 0.000 | 0.517 | 21.914 | 7.534 | 18.038 | 0.000 | 0.332 | 0.000 | 0.000 | -4.292 | 0.000 | -0.217 | -23.419 |
G NE APARTMENT | 0.510 | -19.100 | 0.000 | 0.000 | 3.630 | 2.413 | 12.213 | 12.850 | 0.000 | 0.505 | 0.000 | 0.000 | -3.555 | 0.000 | -0.735 | -8.731 |
G N1 APARTMENT | 0.258 | -14.141 | 0.000 | 0.000 | 3.629 | 2.413 | 12.213 | 6.272 | 0.000 | 0.319 | 0.000 | 0.000 | -2.263 | 0.000 | -0.635 | -8.065 |
G N2 APARTMENT | 0.255 | -14.144 | 0.000 | 0.000 | 3.629 | 2.413 | 12.213 | 6.272 | 0.000 | 0.319 | 0.000 | 0.000 | -2.262 | 0.000 | -0.635 | -8.061 |
G S1 APARTMENT | 0.006 | -18.737 | 0.000 | 0.000 | 3.592 | 2.413 | 12.213 | 12.584 | 0.000 | 0.319 | 0.000 | 0.000 | -2.271 | 0.000 | -0.772 | -9.348 |
G S2 APARTMENT | 0.005 | -19.743 | 0.000 | 0.000 | 3.591 | 2.413 | 12.213 | 12.556 | 0.000 | 0.319 | 0.000 | 0.000 | -2.280 | 0.000 | -0.774 | -8.300 |
M SW APARTMENT | 0.019 | -81.462 | 0.000 | 0.000 | 3.527 | 2.413 | 12.213 | 18.631 | 0.000 | 0.713 | 49.366 | 0.000 | -4.401 | 0.000 | -1.019 | -0.000 |
M NW APARTMENT | 0.172 | -65.533 | 0.000 | 0.000 | 3.540 | 2.413 | 12.213 | 12.406 | 0.000 | 0.712 | 39.546 | 0.000 | -4.470 | 0.000 | -0.999 | -0.000 |
M SE APARTMENT | 0.011 | -81.767 | 0.000 | 0.000 | 3.529 | 2.413 | 12.213 | 18.572 | 0.000 | 0.713 | 49.623 | 0.000 | -4.288 | 0.000 | -1.019 | -0.000 |
M NE APARTMENT | 0.085 | -65.718 | 0.000 | 0.000 | 3.543 | 2.413 | 12.213 | 12.225 | 0.000 | 0.712 | 39.770 | 0.000 | -4.240 | 0.000 | -1.003 | -0.000 |
M N1 APARTMENT | 0.015 | -53.397 | 0.000 | 0.000 | 3.532 | 2.413 | 12.213 | 5.864 | 0.000 | 0.446 | 32.591 | 0.000 | -2.777 | 0.000 | -0.899 | 0.000 |
M N2 APARTMENT | 0.014 | -53.411 | 0.000 | 0.000 | 3.532 | 2.413 | 12.213 | 5.863 | 0.000 | 0.446 | 32.607 | 0.000 | -2.777 | 0.000 | -0.899 | 0.000 |
M S1 APARTMENT | 0.000 | -70.025 | 0.000 | 0.000 | 3.521 | 2.413 | 12.213 | 12.176 | 0.000 | 0.446 | 42.822 | 0.000 | -2.652 | 0.000 | -0.914 | 0.000 |
M S2 APARTMENT | 0.000 | -70.037 | 0.000 | 0.000 | 3.521 | 2.413 | 12.213 | 12.176 | 0.000 | 0.446 | 42.833 | 0.000 | -2.652 | 0.000 | -0.914 | 0.000 |
T SW APARTMENT | 0.589 | -41.558 | 0.000 | 0.000 | 3.567 | 2.413 | 12.213 | 18.244 | 0.000 | 0.932 | 8.805 | 0.000 | -4.080 | 0.000 | -1.124 | -0.000 |
T NW APARTMENT | 1.121 | -34.578 | 0.000 | 0.000 | 3.582 | 2.413 | 12.213 | 12.100 | 0.000 | 0.931 | 7.399 | 0.000 | -4.112 | 0.000 | -1.068 | -0.001 |
T SE APARTMENT | 0.436 | -41.546 | 0.000 | 0.000 | 3.570 | 2.413 | 12.213 | 18.206 | 0.000 | 0.932 | 8.881 | 0.000 | -3.980 | 0.000 | -1.125 | -0.000 |
T NE APARTMENT | 0.827 | -34.390 | 0.000 | 0.000 | 3.586 | 2.413 | 12.213 | 11.963 | 0.000 | 0.931 | 7.460 | 0.000 | -3.918 | 0.000 | -1.085 | -0.000 |
T N1 APARTMENT | 0.247 | -28.008 | 0.000 | 0.000 | 3.577 | 2.413 | 12.213 | 5.759 | 0.000 | 0.580 | 6.685 | 0.000 | -2.529 | 0.000 | -0.936 | -0.000 |
T N2 APARTMENT | 0.243 | -28.018 | 0.000 | 0.000 | 3.577 | 2.413 | 12.213 | 5.757 | 0.000 | 0.580 | 6.700 | 0.000 | -2.528 | 0.000 | -0.937 | -0.000 |
T S1 APARTMENT | 0.041 | -35.431 | 0.000 | 0.000 | 3.558 | 2.413 | 12.213 | 11.968 | 0.000 | 0.581 | 8.136 | 0.000 | -2.486 | 0.000 | -0.994 | -0.000 |
T S2 APARTMENT | 0.041 | -35.443 | 0.000 | 0.000 | 3.558 | 2.413 | 12.213 | 11.967 | 0.000 | 0.581 | 8.148 | 0.000 | -2.485 | 0.000 | -0.994 | -0.000 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.487 | 0.000 | 0.084 | 0.000 | 0.000 | -0.416 | 0.000 | -0.077 | -17.148 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 1.609 | 0.000 | 6.242 | 0.001 | 0.000 | -0.974 | 0.000 | -6.505 | -23.707 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.511 | 0.000 | 0.070 | 0.000 | 0.000 | -0.474 | 0.000 | -0.066 | -17.111 |
Total Facility | 12.891 | -976.552 | 0.000 | 0.000 | 82.623 | 128.627 | 294.692 | 297.317 | 0.000 | 20.204 | 391.375 | 0.000 | -80.685 | 0.000 | -27.920 | -142.575 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 06-JUN-16:02 | 0.00 | -3040.70 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2404.08 | 0.00 | 164.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -344.96 |
G NW APARTMENT | 06-JUN-16:25 | 0.00 | -3051.01 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2483.87 | 0.00 | 149.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -400.11 |
OFFICE | 07-MAY-06:01 | 0.00 | -7558.25 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 314.45 | 0.00 | 10.55 | 6658.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 12-JUN-17:08 | 0.00 | -2459.94 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1352.39 | 0.00 | 59.07 | 123.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G N1 APARTMENT | 12-JUN-17:03 | 0.00 | -1869.63 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 927.15 | 0.00 | 35.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18.03 |
G N2 APARTMENT | 12-JUN-17:03 | 0.00 | -1860.37 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 927.35 | 0.00 | 35.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -27.49 |
G S1 APARTMENT | 27-SEP-14:15 | 0.00 | -1894.47 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1579.47 | 0.00 | 48.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -224.62 |
G S2 APARTMENT | 22-SEP-14:15 | 0.00 | -1919.44 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1438.81 | 0.00 | 53.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -64.72 |
M SW APARTMENT | 05-MAY-16:02 | 0.00 | -7365.95 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2332.67 | 0.00 | 290.16 | 3925.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 06-JUN-16:02 | 0.00 | -7327.49 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2529.32 | 0.00 | 235.68 | 3745.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 15-APR-14:15 | 0.00 | -6131.47 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1820.55 | 0.00 | 303.05 | 3516.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 06-JUN-16:02 | 0.00 | -6040.61 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 1457.72 | 0.00 | 235.68 | 3529.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 12-JUN-17:12 | 0.00 | -4473.58 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 923.36 | 0.00 | 51.15 | 2574.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 12-JUN-17:12 | 0.00 | -4458.91 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 923.49 | 0.00 | 51.15 | 2559.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 17-OCT-14:15 | 0.00 | -4942.10 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1772.34 | 0.00 | 74.50 | 2603.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 17-OCT-14:15 | 0.00 | -4943.21 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1772.31 | 0.00 | 74.50 | 2604.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 06-JUN-16:02 | 0.00 | -4683.44 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2325.28 | 0.00 | 311.09 | 1229.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 06-JUN-16:02 | 0.00 | -4702.61 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2462.87 | 0.00 | 311.09 | 1111.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 15-APR-14:15 | 0.00 | -4007.73 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1767.49 | 0.00 | 399.83 | 1348.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 06-JUN-16:02 | 0.00 | -3899.76 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 1414.65 | 0.00 | 311.09 | 1356.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 06-JUN-16:02 | 0.00 | -3079.62 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 925.53 | 0.00 | 187.65 | 1149.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 06-JUN-16:02 | 0.00 | -3064.96 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 925.84 | 0.00 | 187.65 | 1134.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 02-OCT-14:15 | 0.00 | -3201.70 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1631.47 | 0.00 | 49.51 | 1029.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 02-OCT-13:30 | 0.00 | -3206.35 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1832.86 | 0.00 | 42.30 | 879.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 06-JUN-16:07 | 0.00 | -90873.45 | 0.00 | 0.00 | 1949.43 | 5316.35 | 14137.32 | 33834.46 | 0.00 | 9960.14 | 25675.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 08-JAN-07:01 | 1126.66 | 0.00 | 0.00 | 0.00 | 162.69 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -722.84 | 0.00 | 0.00 | -1042.74 |
G NW APARTMENT | 02-JAN-04:00 | 352.91 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -679.53 | 0.00 | 0.00 | -101.13 |
OFFICE | 03-JAN-07:01 | 1955.68 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -738.16 | 0.00 | -20.12 | -1771.96 |
G NE APARTMENT | 06-JAN-08:02 | 451.16 | 0.00 | 0.00 | 0.00 | 74.03 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -36.96 | 0.00 | -2.48 | -917.45 |
G N1 APARTMENT | 01-JAN-07:01 | 1054.57 | 0.00 | 0.00 | 0.00 | 162.98 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -394.79 | 0.00 | 0.00 | -1299.00 |
G N2 APARTMENT | 02-JAN-07:01 | 1039.53 | 0.00 | 0.00 | 0.00 | 163.06 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -407.11 | 0.00 | 0.00 | -1271.71 |
G S1 APARTMENT | 19-FEB-24:00 | 81.89 | 0.00 | 0.00 | 0.00 | 162.99 | 36.01 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -129.11 | 0.00 | -3.78 | -489.40 |
G S2 APARTMENT | 01-FEB-15:00 | 69.89 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 488.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -63.19 | -947.75 |
M SW APARTMENT | 29-DEC-18:00 | 266.53 | 0.00 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 0.00 | 0.00 | 0.00 | 215.59 | 0.00 | -738.46 | 0.00 | -561.07 | 0.00 |
M NW APARTMENT | 24-DEC-12:30 | 428.39 | 0.00 | 0.00 | 0.00 | 41.20 | 28.81 | 406.15 | 342.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -118.09 | -1128.73 |
M SE APARTMENT | 29-DEC-17:00 | 225.75 | 0.00 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 0.00 | 0.00 | 0.00 | 400.44 | 0.00 | -737.40 | 0.00 | -509.42 | 0.00 |
M NE APARTMENT | 04-JAN-14:15 | 379.33 | 0.00 | 0.00 | 0.00 | 40.89 | 28.81 | 382.60 | 308.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -75.77 | -1064.74 |
M N1 APARTMENT | 04-JAN-13:45 | 221.61 | 0.00 | 0.00 | 0.00 | 41.04 | 28.81 | 388.49 | 196.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -78.99 | -797.32 |
M N2 APARTMENT | 04-JAN-13:45 | 221.54 | 0.00 | 0.00 | 0.00 | 41.06 | 28.81 | 388.49 | 196.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -78.71 | -797.75 |
M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 03-JAN-07:00 | 593.86 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -764.25 | 0.00 | -35.04 | -402.93 |
T NW APARTMENT | 03-JAN-07:00 | 732.19 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -754.39 | 0.00 | -35.04 | -551.11 |
T SE APARTMENT | 03-JAN-07:00 | 603.16 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -756.17 | 0.00 | -35.04 | -420.30 |
T NE APARTMENT | 02-JAN-05:00 | 761.01 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -671.75 | 0.00 | 0.00 | -545.81 |
T N1 APARTMENT | 02-JAN-05:00 | 400.90 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -411.74 | 0.00 | 0.00 | -445.72 |
T N2 APARTMENT | 02-JAN-05:00 | 406.09 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -411.58 | 0.00 | 0.00 | -451.07 |
T S1 APARTMENT | 21-JAN-07:01 | 1186.17 | 0.00 | 0.00 | 0.00 | 162.38 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -443.98 | 0.00 | 0.00 | -1380.80 |
T S2 APARTMENT | 08-JAN-07:01 | 1195.97 | 0.00 | 0.00 | 0.00 | 162.31 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -436.17 | 0.00 | 0.00 | -1398.34 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 02-JAN-07:01 | 3787.33 | 0.00 | 0.00 | 0.00 | 3654.50 | 4156.84 | 9398.91 | 0.00 | 0.00 | 0.00 | 909.45 | 0.00 | -13627.16 | 0.00 | -8279.87 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Sec1.1A-General InformationData | |
Weather File | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 7.75 |
Number of hours cooling loads not met | 1.75 |
Number of hours not met | 9.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 3.74 | 9905.98 | 0.00 | 0.00 |
Space Cooling | 421.34 | 35966.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 287.25 | 9108.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 296.75 | 15912.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1721.20 | 3.74 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1721.20 |
Natural Gas | 0.00 | 3.74 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1724.94 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 134.42 |
Fans-Interior | 91.64 |
Service Water Heating | 94.67 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.58 |
Subtotal | 549.10 |
Natural Gas [MJ/m2] | |
Space Heating | 1.19 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 1.19 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 9.57 |
Space Heating | 0.22 |
Space Cooling | 24.43 |
Fans-Interior | 16.65 |
Service Water Heating | 17.20 |
Receptacle Equipment | 29.65 |
Miscellaneous | 2.29 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.244085 |
G NW APARTMENT DIRECT AIR | 0.247491 |
OFFICE DIRECT AIR | 0.501396 |
G NE APARTMENT DIRECT AIR | 0.210608 |
G N1 APARTMENT DIRECT AIR | 0.159356 |
G N2 APARTMENT DIRECT AIR | 0.158793 |
G S1 APARTMENT DIRECT AIR | 0.152624 |
G S2 APARTMENT DIRECT AIR | 0.153655 |
M SW APARTMENT DIRECT AIR | 0.595947 |
M NW APARTMENT DIRECT AIR | 0.604108 |
M SE APARTMENT DIRECT AIR | 0.526512 |
M NE APARTMENT DIRECT AIR | 0.528490 |
M N1 APARTMENT DIRECT AIR | 0.397555 |
M N2 APARTMENT DIRECT AIR | 0.396654 |
M S1 APARTMENT DIRECT AIR | 0.381446 |
M S2 APARTMENT DIRECT AIR | 0.380556 |
T SW APARTMENT DIRECT AIR | 0.379700 |
T NW APARTMENT DIRECT AIR | 0.381855 |
T SE APARTMENT DIRECT AIR | 0.344757 |
T NE APARTMENT DIRECT AIR | 0.337123 |
T N1 APARTMENT DIRECT AIR | 0.262156 |
T N2 APARTMENT DIRECT AIR | 0.261242 |
T S1 APARTMENT DIRECT AIR | 0.262896 |
T S2 APARTMENT DIRECT AIR | 0.263031 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.244085 |
SPLIT GNW MAIN BRANCH | 0.247491 |
SPLIT OFFICE MAIN BRANCH | 0.501396 |
SPLIT GNE MAIN BRANCH | 0.210608 |
SPLIT GN1 MAIN BRANCH | 0.159356 |
SPLIT GN2 MAIN BRANCH | 0.158793 |
SPLIT GS1 MAIN BRANCH | 0.152624 |
SPLIT GS2 MAIN BRANCH | 0.153655 |
SPLIT MSW MAIN BRANCH | 0.595947 |
SPLIT MNW MAIN BRANCH | 0.604108 |
SPLIT MSE MAIN BRANCH | 0.526512 |
SPLIT MNE MAIN BRANCH | 0.528490 |
SPLIT MN1 MAIN BRANCH | 0.397555 |
SPLIT MN2 MAIN BRANCH | 0.396654 |
SPLIT MS1 MAIN BRANCH | 0.381446 |
SPLIT MS2 MAIN BRANCH | 0.380556 |
SPLIT TSW MAIN BRANCH | 0.379700 |
SPLIT TNW MAIN BRANCH | 0.381855 |
SPLIT TSE MAIN BRANCH | 0.344757 |
SPLIT TNE MAIN BRANCH | 0.337123 |
SPLIT TN1 MAIN BRANCH | 0.262156 |
SPLIT TN2 MAIN BRANCH | 0.261242 |
SPLIT TS1 MAIN BRANCH | 0.262896 |
SPLIT TS2 MAIN BRANCH | 0.263031 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.244085 |
SPLIT GNW | 0.247491 |
SPLIT OFFICE | 0.501396 |
SPLIT GNE | 0.210608 |
SPLIT GN1 | 0.159356 |
SPLIT GN2 | 0.158793 |
SPLIT GS1 | 0.152624 |
SPLIT GS2 | 0.153655 |
SPLIT MSW | 0.595947 |
SPLIT MNW | 0.604108 |
SPLIT MSE | 0.526512 |
SPLIT MNE | 0.528490 |
SPLIT MN1 | 0.397555 |
SPLIT MN2 | 0.396654 |
SPLIT MS1 | 0.381446 |
SPLIT MS2 | 0.380556 |
SPLIT TSW | 0.379700 |
SPLIT TNW | 0.381855 |
SPLIT TSE | 0.344757 |
SPLIT TNE | 0.337123 |
SPLIT TN1 | 0.262156 |
SPLIT TN2 | 0.261242 |
SPLIT TS1 | 0.262896 |
SPLIT TS2 | 0.263031 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.244085 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.247491 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.501396 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.210608 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.159356 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.158793 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.152624 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.153655 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.595947 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.604108 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.526512 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.528490 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.397555 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.396654 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.381446 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.380556 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.379700 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.381855 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.344757 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.337123 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.262156 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.261242 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.262896 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.263031 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.244085 | 4787.41 | 0.741293 |
SPLIT GNW COOLING COIL | 0.247491 | 4827.14 | 0.743034 |
SPLIT OFFICE COOLING COIL | 0.501396 | 8586.16 | 0.786397 |
SPLIT GNE COOLING COIL | 0.210608 | 4138.71 | 0.740701 |
SPLIT GN1 COOLING COIL | 0.159356 | 3225.69 | 0.731662 |
SPLIT GN2 COOLING COIL | 0.158793 | 3216.07 | 0.731495 |
SPLIT GS1 COOLING COIL | 0.152624 | 3110.44 | 0.729629 |
SPLIT GS2 COOLING COIL | 0.153655 | 3089.66 | 0.733669 |
SPLIT MSW COOLING COIL | 0.595947 | 11406.94 | 0.748959 |
SPLIT MNW COOLING COIL | 0.604108 | 11506.03 | 0.750537 |
SPLIT MSE COOLING COIL | 0.526512 | 10449.59 | 0.737649 |
SPLIT MNE COOLING COIL | 0.528490 | 10168.75 | 0.747302 |
SPLIT MN1 COOLING COIL | 0.397555 | 7801.55 | 0.741133 |
SPLIT MN2 COOLING COIL | 0.396654 | 7786.21 | 0.741040 |
SPLIT MS1 COOLING COIL | 0.381446 | 7527.09 | 0.739417 |
SPLIT MS2 COOLING COIL | 0.380556 | 7511.93 | 0.739318 |
SPLIT TSW COOLING COIL | 0.379700 | 7165.97 | 0.753476 |
SPLIT TNW COOLING COIL | 0.381855 | 7178.43 | 0.754743 |
SPLIT TSE COOLING COIL | 0.344757 | 6661.12 | 0.745991 |
SPLIT TNE COOLING COIL | 0.337123 | 6508.76 | 0.746226 |
SPLIT TN1 COOLING COIL | 0.262156 | 5082.05 | 0.744944 |
SPLIT TN2 COOLING COIL | 0.261242 | 5066.30 | 0.744822 |
SPLIT TS1 COOLING COIL | 0.262896 | 5213.79 | 0.737876 |
SPLIT TS2 COOLING COIL | 0.263031 | 5216.14 | 0.737895 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.244085 | 0.244085 | 0.244085 | 0.244085 | 1386.44 | 4787.41 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.247491 | 0.247491 | 0.247491 | 0.247491 | 1337.71 | 4827.14 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.501396 | 0.501396 | 0.501396 | 0.501396 | 2768.38 | 8586.16 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.210608 | 0.210608 | 0.210608 | 0.210608 | 1337.71 | 4138.71 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.159356 | 0.159356 | 0.159356 | 0.159356 | 1337.71 | 3225.69 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.158793 | 0.158793 | 0.158793 | 0.158793 | 1337.71 | 3216.07 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.152624 | 0.152624 | 0.152624 | 0.152624 | 1337.71 | 3110.44 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.153655 | 0.153655 | 0.153655 | 0.153655 | 1337.71 | 3089.66 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.595947 | 0.595947 | 0.595947 | 0.595947 | 2675.42 | 11406.94 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.604108 | 0.604108 | 0.604108 | 0.604108 | 2675.42 | 11506.03 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.526512 | 0.526512 | 0.526512 | 0.526512 | 2675.42 | 10449.59 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.528490 | 0.528490 | 0.528490 | 0.528490 | 2675.42 | 10168.75 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.397555 | 0.397555 | 0.397555 | 0.397555 | 2675.42 | 7801.55 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.396654 | 0.396654 | 0.396654 | 0.396654 | 2675.42 | 7786.21 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.381446 | 0.381446 | 0.381446 | 0.381446 | 2675.42 | 7527.09 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.380556 | 0.380556 | 0.380556 | 0.380556 | 2675.42 | 7511.93 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.379700 | 0.379700 | 0.379700 | 0.379700 | 1908.62 | 7165.97 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.381855 | 0.381855 | 0.381855 | 0.381855 | 1909.49 | 7178.43 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.344757 | 0.344757 | 0.344757 | 0.344757 | 1903.43 | 6661.12 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.337123 | 0.337123 | 0.337123 | 0.337123 | 1904.30 | 6508.76 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.262156 | 0.262156 | 0.262156 | 0.262156 | 1424.96 | 5082.05 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.261242 | 0.261242 | 0.261242 | 0.261242 | 1424.81 | 5066.30 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.262896 | 0.262896 | 0.262896 | 0.262896 | 1422.53 | 5213.79 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.263031 | 0.263031 | 0.263031 | 0.263031 | 1422.38 | 5216.14 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.244085 |
SPLIT GNW SUPPLY FAN | 0.247491 |
SPLIT OFFICE SUPPLY FAN | 0.501396 |
SPLIT GNE SUPPLY FAN | 0.210608 |
SPLIT GN1 SUPPLY FAN | 0.159356 |
SPLIT GN2 SUPPLY FAN | 0.158793 |
SPLIT GS1 SUPPLY FAN | 0.152624 |
SPLIT GS2 SUPPLY FAN | 0.153655 |
SPLIT MSW SUPPLY FAN | 0.595947 |
SPLIT MNW SUPPLY FAN | 0.604108 |
SPLIT MSE SUPPLY FAN | 0.526512 |
SPLIT MNE SUPPLY FAN | 0.528490 |
SPLIT MN1 SUPPLY FAN | 0.397555 |
SPLIT MN2 SUPPLY FAN | 0.396654 |
SPLIT MS1 SUPPLY FAN | 0.381446 |
SPLIT MS2 SUPPLY FAN | 0.380556 |
SPLIT TSW SUPPLY FAN | 0.379700 |
SPLIT TNW SUPPLY FAN | 0.381855 |
SPLIT TSE SUPPLY FAN | 0.344757 |
SPLIT TNE SUPPLY FAN | 0.337123 |
SPLIT TN1 SUPPLY FAN | 0.262156 |
SPLIT TN2 SUPPLY FAN | 0.261242 |
SPLIT TS1 SUPPLY FAN | 0.262896 |
SPLIT TS2 SUPPLY FAN | 0.263031 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1386.44 |
SPLIT GNW HEATING COIL | 1337.71 |
SPLIT OFFICE HEATING COIL | 2768.38 |
SPLIT GNE HEATING COIL | 1337.71 |
SPLIT GN1 HEATING COIL | 1337.71 |
SPLIT GN2 HEATING COIL | 1337.71 |
SPLIT GS1 HEATING COIL | 1337.71 |
SPLIT GS2 HEATING COIL | 1337.71 |
SPLIT MSW HEATING COIL | 2675.42 |
SPLIT MNW HEATING COIL | 2675.42 |
SPLIT MSE HEATING COIL | 2675.42 |
SPLIT MNE HEATING COIL | 2675.42 |
SPLIT MN1 HEATING COIL | 2675.42 |
SPLIT MN2 HEATING COIL | 2675.42 |
SPLIT MS1 HEATING COIL | 2675.42 |
SPLIT MS2 HEATING COIL | 2675.42 |
SPLIT TSW HEATING COIL | 1908.62 |
SPLIT TNW HEATING COIL | 1909.49 |
SPLIT TSE HEATING COIL | 1903.43 |
SPLIT TNE HEATING COIL | 1904.30 |
SPLIT TN1 HEATING COIL | 1424.96 |
SPLIT TN2 HEATING COIL | 1424.81 |
SPLIT TS1 HEATING COIL | 1422.53 |
SPLIT TS2 HEATING COIL | 1422.38 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:30
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.10 | 13.39 |
February | 23.62 | 16.97 |
March | 24.25 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.39 | 25.09 |
November | 24.11 | 19.63 |
December | 23.39 | 14.52 |
Annual Sum or Average | 24.11 | 24.88 |
Minimum of Months | 23.10 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.54 | 13.39 |
February | 23.32 | 16.97 |
March | 24.18 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.38 | 25.09 |
November | 23.91 | 19.63 |
December | 22.81 | 14.52 |
Annual Sum or Average | 23.96 | 24.88 |
Minimum of Months | 22.54 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.55 | 13.39 |
February | 24.41 | 16.97 |
March | 25.61 | 22.37 |
April | 26.83 | 29.13 |
May | 27.25 | 32.98 |
June | 27.57 | 33.60 |
July | 27.61 | 31.67 |
August | 27.37 | 30.03 |
September | 27.47 | 28.75 |
October | 26.36 | 25.09 |
November | 25.33 | 19.63 |
December | 23.93 | 14.52 |
Annual Sum or Average | 26.11 | 24.88 |
Minimum of Months | 23.55 | 13.39 |
Maximum of Months | 27.61 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.46 | 13.39 |
February | 23.32 | 16.97 |
March | 24.17 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.37 | 25.09 |
November | 23.89 | 19.63 |
December | 22.74 | 14.52 |
Annual Sum or Average | 23.95 | 24.88 |
Minimum of Months | 22.46 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.39 | 13.39 |
February | 23.22 | 16.97 |
March | 24.14 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.37 | 25.09 |
November | 23.88 | 19.63 |
December | 22.69 | 14.52 |
Annual Sum or Average | 23.93 | 24.88 |
Minimum of Months | 22.39 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.39 | 13.39 |
February | 23.22 | 16.97 |
March | 24.14 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.37 | 25.09 |
November | 23.88 | 19.63 |
December | 22.68 | 14.52 |
Annual Sum or Average | 23.92 | 24.88 |
Minimum of Months | 22.39 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.16 | 13.39 |
February | 23.66 | 16.97 |
March | 24.23 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.39 | 25.09 |
November | 24.13 | 19.63 |
December | 23.49 | 14.52 |
Annual Sum or Average | 24.12 | 24.88 |
Minimum of Months | 23.16 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.17 | 13.39 |
February | 23.68 | 16.97 |
March | 24.24 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.39 | 25.09 |
November | 24.15 | 19.63 |
December | 23.50 | 14.52 |
Annual Sum or Average | 24.13 | 24.88 |
Minimum of Months | 23.17 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.17 | 13.39 |
February | 24.34 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.29 | 14.52 |
Annual Sum or Average | 24.37 | 24.88 |
Minimum of Months | 24.17 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.82 | 13.39 |
February | 24.25 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.39 | 19.63 |
December | 24.08 | 14.52 |
Annual Sum or Average | 24.31 | 24.88 |
Minimum of Months | 23.82 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.14 | 13.39 |
February | 24.33 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.27 | 14.52 |
Annual Sum or Average | 24.36 | 24.88 |
Minimum of Months | 24.14 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.80 | 13.39 |
February | 24.24 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.38 | 19.63 |
December | 24.06 | 14.52 |
Annual Sum or Average | 24.31 | 24.88 |
Minimum of Months | 23.80 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.00 | 13.39 |
February | 24.32 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.22 | 14.52 |
Annual Sum or Average | 24.34 | 24.88 |
Minimum of Months | 24.00 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.00 | 13.39 |
February | 24.32 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.22 | 14.52 |
Annual Sum or Average | 24.34 | 24.88 |
Minimum of Months | 24.00 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 13.39 |
February | 24.38 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.37 | 14.52 |
Annual Sum or Average | 24.39 | 24.88 |
Minimum of Months | 24.29 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 13.39 |
February | 24.38 | 16.97 |
March | 24.40 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.40 | 19.63 |
December | 24.37 | 14.52 |
Annual Sum or Average | 24.39 | 24.88 |
Minimum of Months | 24.29 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.51 | 13.39 |
February | 23.96 | 16.97 |
March | 24.38 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.28 | 19.63 |
December | 23.66 | 14.52 |
Annual Sum or Average | 24.22 | 24.88 |
Minimum of Months | 23.51 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.19 | 13.39 |
February | 23.79 | 16.97 |
March | 24.36 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.20 | 19.63 |
December | 23.33 | 14.52 |
Annual Sum or Average | 24.14 | 24.88 |
Minimum of Months | 23.19 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 13.39 |
February | 23.94 | 16.97 |
March | 24.38 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.26 | 19.63 |
December | 23.64 | 14.52 |
Annual Sum or Average | 24.21 | 24.88 |
Minimum of Months | 23.50 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.19 | 13.39 |
February | 23.80 | 16.97 |
March | 24.36 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.39 | 25.09 |
November | 24.17 | 19.63 |
December | 23.33 | 14.52 |
Annual Sum or Average | 24.14 | 24.88 |
Minimum of Months | 23.19 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.21 | 13.39 |
February | 23.86 | 16.97 |
March | 24.37 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.23 | 19.63 |
December | 23.41 | 14.52 |
Annual Sum or Average | 24.16 | 24.88 |
Minimum of Months | 23.21 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.21 | 13.39 |
February | 23.86 | 16.97 |
March | 24.37 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.23 | 19.63 |
December | 23.41 | 14.52 |
Annual Sum or Average | 24.16 | 24.88 |
Minimum of Months | 23.21 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.62 | 13.39 |
February | 24.05 | 16.97 |
March | 24.39 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.32 | 19.63 |
December | 23.81 | 14.52 |
Annual Sum or Average | 24.25 | 24.88 |
Minimum of Months | 23.62 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.62 | 13.39 |
February | 24.05 | 16.97 |
March | 24.39 | 22.37 |
April | 24.40 | 29.13 |
May | 24.40 | 32.98 |
June | 24.40 | 33.60 |
July | 24.40 | 31.67 |
August | 24.40 | 30.03 |
September | 24.40 | 28.75 |
October | 24.40 | 25.09 |
November | 24.32 | 19.63 |
December | 23.81 | 14.52 |
Annual Sum or Average | 24.25 | 24.88 |
Minimum of Months | 23.62 | 13.39 |
Maximum of Months | 24.40 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.22 | 13.39 |
February | 25.31 | 16.97 |
March | 26.55 | 22.37 |
April | 27.46 | 29.13 |
May | 27.94 | 32.98 |
June | 28.00 | 33.60 |
July | 27.86 | 31.67 |
August | 27.67 | 30.03 |
September | 27.41 | 28.75 |
October | 26.93 | 25.09 |
November | 25.99 | 19.63 |
December | 24.58 | 14.52 |
Annual Sum or Average | 26.67 | 24.88 |
Minimum of Months | 24.22 | 13.39 |
Maximum of Months | 28.00 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.31 | 13.39 |
February | 23.51 | 16.97 |
March | 25.13 | 22.37 |
April | 26.79 | 29.13 |
May | 27.62 | 32.98 |
June | 28.37 | 33.60 |
July | 28.08 | 31.67 |
August | 27.75 | 30.03 |
September | 27.52 | 28.75 |
October | 26.13 | 25.09 |
November | 24.61 | 19.63 |
December | 22.84 | 14.52 |
Annual Sum or Average | 25.90 | 24.88 |
Minimum of Months | 22.31 | 13.39 |
Maximum of Months | 28.37 | 33.60 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.85 | 13.39 |
February | 26.41 | 16.97 |
March | 26.91 | 22.37 |
April | 27.36 | 29.13 |
May | 27.57 | 32.98 |
June | 27.56 | 33.60 |
July | 27.46 | 31.67 |
August | 27.36 | 30.03 |
September | 27.26 | 28.75 |
October | 27.12 | 25.09 |
November | 26.75 | 19.63 |
December | 26.16 | 14.52 |
Annual Sum or Average | 26.98 | 24.88 |
Minimum of Months | 25.85 | 13.39 |
Maximum of Months | 27.57 | 33.60 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:30
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.121006E+12 | 74834.112 | 14-JAN-18:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 5856.411 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22331.422 | 0.000 | 0.000 | 0.000 |
February | 0.114230E+12 | 80322.283 | 22-FEB-18:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 11553.565 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22122.440 | 0.000 | 0.000 | 0.000 |
March | 0.137170E+12 | 84654.625 | 28-MAR-17:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 22309.380 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18207.296 | 0.000 | 0.000 | 0.000 |
April | 0.146945E+12 | 89479.280 | 28-APR-17:30 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 28223.517 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17117.814 | 0.000 | 0.000 | 0.000 |
May | 0.162885E+12 | 93350.135 | 05-MAY-17:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 33731.832 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 15480.354 | 0.000 | 0.000 | 0.000 |
June | 0.162212E+12 | 95749.906 | 05-JUN-17:30 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 34920.570 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16691.387 | 0.000 | 0.000 | 0.000 |
July | 0.166961E+12 | 96017.217 | 02-JUL-17:30 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 35966.531 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 15912.737 | 0.000 | 0.000 | 0.000 |
August | 0.163139E+12 | 92731.375 | 28-AUG-17:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 30227.336 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18366.090 | 0.000 | 0.000 | 0.000 |
September | 0.152715E+12 | 91513.045 | 21-SEP-17:15 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 27332.774 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20042.323 | 0.000 | 0.000 | 0.000 |
October | 0.144116E+12 | 87323.583 | 02-OCT-17:30 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 22626.669 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20558.965 | 0.000 | 0.000 | 0.000 |
November | 0.127503E+12 | 78283.774 | 01-NOV-17:45 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 12458.810 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19178.686 | 0.000 | 0.000 | 0.000 |
December | 0.122323E+12 | 71817.437 | 27-DEC-18:30 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 5857.078 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19314.081 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.172120E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.114230E+12 | 71817.437 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 5856.411 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 15480.354 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.166961E+12 | 96017.217 | 8572.775 | 26456.413 | 9108.761 | 0.000 | 35966.531 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22331.422 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:30
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.256492E+10 | 9905.977 | 03-JAN-06:00 | 9905.977 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9905.977 |
February | 0.258739E+09 | 4079.127 | 02-FEB-06:00 | 4079.127 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4079.127 |
March | 0.000 | 0.000 | 01-MAR-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.000 | 0.000 | 01-APR-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.000 | 0.000 | 01-MAY-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.000 | 0.000 | 01-OCT-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.000 | 0.000 | 01-NOV-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.916578E+09 | 9153.974 | 23-DEC-04:00 | 9153.974 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9153.974 |
Annual Sum or Average | 0.374024E+10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.256492E+10 | 9905.977 | 9905.977 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9905.977 |