Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Fairbanks Intl Arpt AK USA TMY3 WMO#=702610

Simulation Timestamp: 2018-10-19 09:20:32


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 2462.93 785.72 872.15
Net Site Energy 2462.93 785.72 872.15
Total Source Energy 5754.22 1835.70 2037.63
Net Source Energy 5754.22 1835.70 2037.63


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 982.18 0.00 0.00 0.00 0.00
Cooling 49.81 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.11 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 214.76 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 500.66 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1480.75 982.18 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 982.18 0.00 0.00 0.00 0.00
Cooling General 49.81 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.11 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 214.76 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 500.66 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.28 0.00 0.00 0.00 0.00 0.00
HVAC 270.97 347.80 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 524.35 347.80 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.11 0.00 0.00 0.00 0.00 0.00
HVAC 244.12 313.33 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 472.39 313.33 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1480.75 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1480.75 100.00
     
Total On-Site and Utility Electric Sources 1480.75 100.00
Total Electricity End Uses 1480.75 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 27.25
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 4607.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Weather File Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Latitude [deg] 64.82
Longitude [deg] -147.8
Elevation [m] 133.00
Time Zone -9.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 29-JUL-18:15 29-JAN-00:15 - - - 01-JAN-07:15
Heating 0.00 139689.41 0.00 0.00 0.00 0.00
Cooling 14959.49 0.00 0.00 0.00 0.00 0.00
Interior Lighting 9689.08 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 23563.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 6809.89 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 31184.17 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 86205.64 139689.41 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 139689.41 0.00 0.00 0.00 0.00
Cooling General 14959.49 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 8059.76 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1629.32 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 23563.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 6809.89 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 31184.17 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 1064.68 0.00 0.00 0.00
Cooling 157.75 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 123.85 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 680.13 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1585.59 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4689.54 1064.68 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 377.01 0.00 0.00 0.00
Cooling 55.86 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 43.86 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 240.84 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 561.47 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1660.62 377.01 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 377.01 0.00 0.00 0.00
Cooling 55.86 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 43.86 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 240.84 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 561.47 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1660.62 377.01 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB -41.90 0.00 -41.90 Wetbulb [C] 0.30 20.00
FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 27.40 10.20 16.10 Wetbulb [C] 3.10 180.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.210 0.217 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.210 0.217 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 9.29 2.493 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 14.12 2.493 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.42_SHGC_0.45 4.65 0.00 0.00 4.65 4.65 2.493 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.42_SHGC_0.45 7.06 0.00 0.00 7.06 7.06 2.493 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.42_SHGC_0.45 3.32 0.00 0.00 3.32 3.32 2.493 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 2.23 2.493 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.493 0.426 0.308              
North Total or Average           112.97 2.493 0.426 0.308              
Non-North Total or Average           193.95 2.493 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.06 83.06 39.11
Exterior Lighting Total 2508.33           39.11



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   2758.65 2203.21 555.44 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   2227.79 1779.24 448.55 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   6994.56 5586.24 1408.32 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   1539.71 1229.70 310.01 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1362.11 1087.86 274.25 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1343.90 1073.31 270.59 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2078.10 1659.69 418.41 0.80 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2128.78 1700.16 428.62 0.80 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   8163.63 6519.93 1643.70 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   6662.00 5320.64 1341.36 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7753.37 6192.27 1561.10 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   5213.23 4163.57 1049.66 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4358.95 3481.30 877.65 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4325.12 3454.28 870.84 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6376.73 5092.81 1283.92 0.80 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6397.90 5109.71 1288.18 0.80 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5184.17 4140.36 1043.80 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   4043.53 3229.39 814.14 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   4949.24 3952.74 996.50 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   3102.35 2477.71 624.64 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2537.85 2026.87 510.98 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2502.36 1998.53 503.84 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4309.88 3442.11 867.77 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4326.19 3455.14 871.06 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 2628.0 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2122.3 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 6663.4 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 1466.8 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1297.6 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1280.3 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1979.7 3.13 10.67 11.09 10.38
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2028.0 3.13 10.67 11.09 10.38
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 7777.1 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 6346.6 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7386.3 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4966.4 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4152.6 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4120.4 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 6074.8 3.13 10.67 11.09 10.38
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 6095.0 3.13 10.67 11.09 10.38
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 4938.7 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3852.1 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 4714.9 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2955.5 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2417.7 3.13 10.67 11.09 10.38
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2383.9 3.13 10.67 11.09 10.38
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4105.8 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4121.4 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   4380.83 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   4322.48 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   7635.65 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   4328.50 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   3561.71 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   3561.83 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   3552.15 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   3692.52 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   7564.91 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   7593.70 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   7580.91 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   7609.73 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   5818.98 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   5819.35 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   5793.87 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   5794.23 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   5899.17 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   5917.55 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   5907.98 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   5926.38 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   5041.35 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   5041.56 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   5021.53 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   5021.73 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 186.67 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 150.75 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.42 473.29 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.09 104.19 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.08 92.17 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.08 90.94 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 140.62 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 144.05 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.49 552.40 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.40 450.79 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.47 524.64 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 352.76 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 294.95 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 292.66 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.39 431.49 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.39 432.92 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 350.79 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 273.61 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 334.89 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 209.92 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 171.73 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 169.32 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 291.63 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 292.74 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1745.88 2095.05 0.139 0.167 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 26.18 0.00698
G NW APARTMENT 1409.88 1691.86 0.112 0.135 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 20:00:00 22.30 0.00698
OFFICE 4340.33 5208.39 0.352 0.423 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:00:00 21.79 0.00698
G NE APARTMENT 974.42 1169.31 0.078 0.093 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 23.91 0.00698
G N1 APARTMENT 862.02 1034.42 0.069 0.082 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:00:00 21.38 0.00698
G N2 APARTMENT 850.49 1020.59 0.068 0.081 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:00:00 21.38 0.00698
G S1 APARTMENT 1315.17 1578.20 0.105 0.126 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
G S2 APARTMENT 1347.24 1616.69 0.107 0.129 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
M SW APARTMENT 5166.56 6199.88 0.411 0.493 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 25.72 0.00698
M NW APARTMENT 4216.14 5059.36 0.335 0.402 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 20:00:00 22.30 0.00698
M SE APARTMENT 4906.92 5888.31 0.390 0.468 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
M NE APARTMENT 3299.31 3959.17 0.262 0.315 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
M N1 APARTMENT 2758.59 3310.31 0.219 0.263 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:00:00 21.38 0.00698
M N2 APARTMENT 2737.18 3284.62 0.218 0.261 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:00:00 21.38 0.00698
M S1 APARTMENT 4035.66 4842.79 0.321 0.385 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
M S2 APARTMENT 4049.06 4858.87 0.322 0.386 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
T SW APARTMENT 3280.95 3937.14 0.261 0.313 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 26.38 0.00698
T NW APARTMENT 2559.05 3070.86 0.204 0.244 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 24.19 0.00698
T SE APARTMENT 3132.27 3758.72 0.249 0.299 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
T NE APARTMENT 1963.41 2356.09 0.156 0.187 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 25.31 0.00698
T N1 APARTMENT 1606.11 1927.33 0.128 0.153 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 20:00:00 22.30 0.00698
T N2 APARTMENT 1583.68 1900.41 0.126 0.151 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 24.95 0.00698
T S1 APARTMENT 2727.61 3273.14 0.217 0.260 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
T S2 APARTMENT 2737.94 3285.53 0.218 0.261 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1981.36 2377.63 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G NW APARTMENT 1992.59 2391.10 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
OFFICE 4065.59 4878.71 0.115 0.138 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G NE APARTMENT 1997.68 2397.22 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G N1 APARTMENT 1349.23 1619.08 0.039 0.047 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G N2 APARTMENT 1349.34 1619.21 0.039 0.047 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G S1 APARTMENT 1341.15 1609.38 0.039 0.047 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G S2 APARTMENT 1459.86 1751.83 0.043 0.051 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
M SW APARTMENT 3071.81 3686.17 0.090 0.108 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M NW APARTMENT 3096.16 3715.39 0.091 0.109 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M SE APARTMENT 3085.34 3702.41 0.090 0.108 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M NE APARTMENT 3109.72 3731.66 0.091 0.109 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M N1 APARTMENT 1595.36 1914.43 0.047 0.056 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M N2 APARTMENT 1595.66 1914.80 0.047 0.056 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M S1 APARTMENT 1574.12 1888.95 0.046 0.055 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
M S2 APARTMENT 1574.43 1889.31 0.046 0.055 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T SW APARTMENT 3325.91 3991.09 0.097 0.117 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T NW APARTMENT 3341.46 4009.75 0.098 0.117 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T SE APARTMENT 3333.36 4000.04 0.097 0.117 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T NE APARTMENT 3348.92 4018.71 0.098 0.117 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T N1 APARTMENT 2600.49 3120.59 0.076 0.091 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T N2 APARTMENT 2600.67 3120.80 0.076 0.091 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T S1 APARTMENT 2583.73 3100.47 0.076 0.091 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006
T S2 APARTMENT 2583.90 3100.68 0.076 0.091 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -41.90 0.00006


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.17 0.17 0.07 0.07
SPLIT GNW 0.13 0.13 0.07 0.07
SPLIT OFFICE 0.42 0.42 0.14 0.14
SPLIT GNE 0.09 0.09 0.07 0.07
SPLIT GN1 0.08 0.08 0.05 0.05
SPLIT GN2 0.08 0.08 0.05 0.05
SPLIT GS1 0.13 0.13 0.05 0.05
SPLIT GS2 0.13 0.13 0.05 0.05
SPLIT MSW 0.49 0.49 0.11 0.11
SPLIT MNW 0.40 0.40 0.11 0.11
SPLIT MSE 0.47 0.47 0.11 0.11
SPLIT MNE 0.31 0.31 0.11 0.11
SPLIT MN1 0.26 0.26 0.06 0.06
SPLIT MN2 0.26 0.26 0.06 0.06
SPLIT MS1 0.39 0.39 0.06 0.06
SPLIT MS2 0.39 0.39 0.06 0.06
SPLIT TSW 0.31 0.31 0.12 0.12
SPLIT TNW 0.24 0.24 0.12 0.12
SPLIT TSE 0.30 0.30 0.12 0.12
SPLIT TNE 0.19 0.19 0.12 0.12
SPLIT TN1 0.15 0.15 0.09 0.09
SPLIT TN2 0.15 0.15 0.09 0.09
SPLIT TS1 0.26 0.26 0.09 0.09
SPLIT TS2 0.26 0.26 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 4395.00 7136.00 3897.50
G NW APARTMENT 4503.00 7443.25 4259.75
OFFICE 964.50 1881.00 954.00
G NE APARTMENT 4520.25 7366.25 4223.25
G N1 APARTMENT 4192.50 7656.00 4053.00
G N2 APARTMENT 4193.25 7649.00 4050.75
G S1 APARTMENT 4005.25 7122.25 3643.25
G S2 APARTMENT 4074.25 7160.00 3733.25
M SW APARTMENT 4204.25 5531.25 2833.00
M NW APARTMENT 4498.25 6089.75 3429.25
M SE APARTMENT 4253.50 5472.25 2751.25
M NE APARTMENT 4591.25 6020.50 3358.25
M N1 APARTMENT 3506.00 6024.50 2575.75
M N2 APARTMENT 3505.25 6016.50 2566.75
M S1 APARTMENT 3026.00 5350.25 1730.50
M S2 APARTMENT 3029.00 5346.00 1727.75
T SW APARTMENT 5317.75 6377.75 4134.75
T NW APARTMENT 5499.50 6755.25 4512.25
T SE APARTMENT 5360.50 6283.75 4079.50
T NE APARTMENT 5566.75 6712.00 4481.50
T N1 APARTMENT 5212.50 6800.50 4333.50
T N2 APARTMENT 5213.75 6797.75 4330.75
T S1 APARTMENT 5020.00 6285.00 3891.00
T S2 APARTMENT 5022.00 6274.50 3887.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 6352.00 7734.50 4607.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.50 0.00 0.50 0.00
G NW APARTMENT 3.25 0.00 3.25 0.00
OFFICE 29.00 0.00 0.25 0.00
G NE APARTMENT 1.00 0.00 1.00 0.00
G N1 APARTMENT 0.50 0.00 0.50 0.00
G N2 APARTMENT 0.50 0.00 0.50 0.00
G S1 APARTMENT 0.75 0.00 0.75 0.00
G S2 APARTMENT 0.75 0.00 0.75 0.00
M SW APARTMENT 1.00 0.00 1.00 0.00
M NW APARTMENT 0.50 0.00 0.50 0.00
M SE APARTMENT 0.50 0.00 0.50 0.00
M NE APARTMENT 0.50 0.00 0.50 0.00
M N1 APARTMENT 1.25 0.00 1.25 0.00
M N2 APARTMENT 0.50 0.00 0.50 0.00
M S1 APARTMENT 1.00 0.00 1.00 0.00
M S2 APARTMENT 1.00 0.00 1.00 0.00
T SW APARTMENT 0.75 0.00 0.75 0.00
T NW APARTMENT 0.50 0.00 0.50 0.00
T SE APARTMENT 2.25 0.00 2.25 0.00
T NE APARTMENT 4.00 0.00 4.00 0.00
T N1 APARTMENT 2.25 0.00 2.25 0.00
T N2 APARTMENT 1.75 0.00 1.75 0.00
T S1 APARTMENT 2.50 0.00 2.50 0.00
T S2 APARTMENT 2.00 0.00 2.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 56.00 0.00 27.25 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.367 0.063 0.000 0.044
G NW APARTMENT 1.71 2.50 268.97 0.354 0.063 0.000 0.044
OFFICE 0.94 1.00 268.97 0.520 0.061 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.354 0.063 0.000 0.044
G N1 APARTMENT 1.71 2.50 268.97 0.354 0.038 0.000 0.043
G N2 APARTMENT 1.71 2.50 268.97 0.354 0.038 0.000 0.043
G S1 APARTMENT 1.71 2.50 268.97 0.354 0.038 0.000 0.044
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.038 0.000 0.044
M SW APARTMENT 1.71 2.50 268.97 0.354 0.091 0.000 0.051
M NW APARTMENT 1.71 2.50 268.97 0.354 0.091 0.000 0.052
M SE APARTMENT 1.71 2.50 268.97 0.354 0.091 0.000 0.051
M NE APARTMENT 1.71 2.50 268.97 0.354 0.091 0.000 0.052
M N1 APARTMENT 1.71 2.50 268.97 0.354 0.055 0.000 0.052
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.055 0.000 0.052
M S1 APARTMENT 1.71 2.50 268.97 0.354 0.055 0.000 0.051
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.055 0.000 0.051
T SW APARTMENT 1.71 2.50 268.97 0.354 0.121 0.000 0.057
T NW APARTMENT 1.71 2.50 268.97 0.354 0.121 0.000 0.057
T SE APARTMENT 1.71 2.50 268.97 0.354 0.121 0.000 0.057
T NE APARTMENT 1.71 2.50 268.97 0.354 0.121 0.000 0.057
T N1 APARTMENT 1.71 2.50 268.97 0.354 0.073 0.000 0.057
T N2 APARTMENT 1.71 2.50 268.97 0.354 0.073 0.000 0.057
T S1 APARTMENT 1.71 2.50 268.97 0.354 0.073 0.000 0.057
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.073 0.000 0.057
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.355 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.502 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 500.66 0.00 01-JAN-00:15 33146.68 16-JAN-07:30
WaterSystems:Electricity 500.66 0.00 01-JAN-00:15 33146.68 16-JAN-07:30
Water Heater:WaterSystems:Electricity 500.66 0.00 01-JAN-00:15 33146.68 16-JAN-07:30
Fans:Electricity 214.76 6809.89 01-JAN-06:15 6809.89 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
ElectricityPurchased:Plant 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
Cogeneration:ElectricityPurchased 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
ElectricityNet:Plant 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
Cogeneration:ElectricityNet 1480.75 18256.66 26-JUN-02:45 86205.64 29-JUL-18:15
ExteriorLights:Electricity 39.11 0.00 01-JAN-11:30 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.11 0.00 01-JAN-11:30 2508.33 01-JAN-00:15
Electricity:HVAC 264.57 6809.89 01-JAN-06:15 23924.01 29-JUL-16:15
General:Fans:Electricity 214.76 6809.89 01-JAN-06:15 6809.89 01-JAN-00:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 49.81 0.00 01-JAN-00:15 17114.12 29-JUL-16:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 982.18 0.00 17-APR-14:00 139689.41 29-JAN-00:15
Gas:HVAC 982.18 0.00 17-APR-14:00 139689.41 29-JAN-00:15
Heating:Gas 982.18 0.00 17-APR-14:00 139689.41 29-JAN-00:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1606.53 3768.17 01-OCT-17:00 183654.67 29-JAN-00:15
EnergyTransfer:Building 622.09 3697.45 01-OCT-17:00 71903.14 29-JAN-00:15
EnergyTransfer:Zone:G SW APARTMENT 17.19 0.04 22-MAY-13:00 2264.26 29-JAN-00:15
Heating:EnergyTransfer 332.59 0.00 18-MAR-16:15 71903.14 29-JAN-00:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 12.20 0.00 09-FEB-11:45 2264.26 29-JAN-00:15
Cooling:EnergyTransfer 289.50 0.00 02-JAN-07:30 56019.44 11-JUL-17:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 4.99 0.00 01-JAN-00:15 1692.85 11-AUG-16:15
EnergyTransfer:Zone:G NW APARTMENT 17.81 0.06 25-MAY-22:15 2344.94 29-JAN-00:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 14.33 0.00 18-MAR-16:15 2344.94 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 3.48 0.00 01-JAN-00:15 1372.58 11-JUL-17:45
EnergyTransfer:Zone:OFFICE 23.65 0.46 21-FEB-11:00 4283.07 29-JAN-07:30
Heating:EnergyTransfer:Zone:OFFICE 1.69 0.00 01-JAN-00:15 4283.07 29-JAN-07:30
Cooling:EnergyTransfer:Zone:OFFICE 21.96 0.00 02-JAN-07:30 3249.12 10-AUG-13:30
EnergyTransfer:Zone:G NE APARTMENT 18.09 0.07 30-MAY-17:45 2356.45 29-JAN-00:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 14.04 0.00 18-MAR-16:15 2356.45 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.05 0.00 01-JAN-00:15 1009.87 11-JUL-17:15
EnergyTransfer:Zone:G N1 APARTMENT 12.04 0.19 29-APR-07:45 1456.40 29-JAN-00:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 8.21 0.00 07-FEB-20:45 1456.40 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 3.83 0.00 01-JAN-00:15 837.97 11-JUL-19:00
EnergyTransfer:Zone:G N2 APARTMENT 12.05 0.18 10-MAY-02:30 1456.55 29-JAN-00:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 8.20 0.00 07-FEB-20:45 1456.55 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 3.86 0.00 01-JAN-00:15 831.78 11-JUL-19:00
EnergyTransfer:Zone:G S1 APARTMENT 11.75 0.27 03-MAY-01:30 1379.58 29-JAN-00:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 6.43 0.00 23-JAN-12:45 1379.58 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 5.32 0.00 01-JAN-00:15 1264.43 11-AUG-15:15
EnergyTransfer:Zone:G S2 APARTMENT 12.96 0.02 29-MAR-19:30 1537.70 29-JAN-00:15
Heating:EnergyTransfer:Zone:G S2 APARTMENT 7.79 0.00 23-JAN-13:30 1537.70 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 5.17 0.00 01-JAN-00:15 1246.07 11-AUG-15:15
EnergyTransfer:Zone:M SW APARTMENT 39.11 0.11 03-APR-09:30 5092.03 11-AUG-16:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 14.65 0.00 21-JAN-20:30 4728.38 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 24.45 0.00 01-JAN-00:15 5092.03 11-AUG-16:15
EnergyTransfer:Zone:M NW APARTMENT 35.63 0.88 12-OCT-20:00 4993.43 29-JAN-00:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 19.14 0.00 21-JAN-20:45 4993.43 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M NW APARTMENT 16.49 0.00 01-JAN-00:15 4160.28 11-JUL-18:15
EnergyTransfer:Zone:M SE APARTMENT 40.99 0.23 07-APR-06:00 4884.90 22-JUL-11:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 14.33 0.00 21-JAN-20:30 4752.64 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 26.66 0.00 01-JAN-00:15 4884.90 22-JUL-11:30
EnergyTransfer:Zone:M NE APARTMENT 37.09 0.07 09-FEB-16:00 5018.38 29-JAN-00:15
Heating:EnergyTransfer:Zone:M NE APARTMENT 18.54 0.00 21-JAN-20:45 5018.38 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M NE APARTMENT 18.54 0.00 01-JAN-00:15 3402.76 11-JUL-17:15
EnergyTransfer:Zone:M N1 APARTMENT 23.83 0.10 28-FEB-21:00 2770.42 11-JUL-19:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 5.89 0.00 02-JAN-18:45 2677.94 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 17.95 0.00 01-JAN-00:15 2770.42 11-JUL-19:00
EnergyTransfer:Zone:M N2 APARTMENT 23.90 0.25 17-OCT-04:00 2762.46 11-JUL-19:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 5.86 0.00 02-JAN-18:45 2678.46 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 18.04 0.00 01-JAN-00:15 2762.46 11-JUL-19:00
EnergyTransfer:Zone:M S1 APARTMENT 31.45 0.06 23-FEB-07:00 4032.95 11-AUG-15:15
Heating:EnergyTransfer:Zone:M S1 APARTMENT 3.67 0.00 02-JAN-18:45 2416.94 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 27.78 0.00 01-JAN-00:15 4032.95 11-AUG-15:15
EnergyTransfer:Zone:M S2 APARTMENT 31.56 0.73 06-MAR-02:00 4041.10 11-AUG-15:15
Heating:EnergyTransfer:Zone:M S2 APARTMENT 3.66 0.00 02-JAN-18:45 2416.90 29-JAN-00:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 27.90 0.00 01-JAN-00:15 4041.10 11-AUG-15:15
EnergyTransfer:Zone:T SW APARTMENT 32.85 0.07 14-JUN-05:15 4239.01 29-JAN-00:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 24.25 0.00 09-FEB-11:45 4239.01 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T SW APARTMENT 8.60 0.00 01-JAN-00:15 3166.12 29-JUL-15:30
EnergyTransfer:Zone:T NW APARTMENT 33.13 0.34 18-SEP-24:00 4337.24 29-JAN-00:15
Heating:EnergyTransfer:Zone:T NW APARTMENT 27.40 0.00 18-MAR-15:15 4337.24 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T NW APARTMENT 5.73 0.00 01-JAN-00:15 2639.27 11-JUL-17:45
EnergyTransfer:Zone:T SE APARTMENT 33.27 0.04 26-JUN-02:00 4256.04 29-JAN-00:15
Heating:EnergyTransfer:Zone:T SE APARTMENT 23.89 0.00 09-FEB-11:30 4256.04 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T SE APARTMENT 9.38 0.00 01-JAN-00:15 3045.38 22-JUL-11:45
EnergyTransfer:Zone:T NE APARTMENT 33.52 0.03 29-AUG-13:30 4354.25 29-JAN-00:15
Heating:EnergyTransfer:Zone:T NE APARTMENT 26.97 0.00 18-MAR-12:45 4354.25 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T NE APARTMENT 6.55 0.00 01-JAN-00:15 2052.70 11-JUL-17:15
EnergyTransfer:Zone:T N1 APARTMENT 24.97 0.43 06-SEP-06:00 2970.59 29-JAN-00:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 19.30 0.00 18-MAR-11:45 2970.59 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 5.67 0.00 01-JAN-00:15 1771.47 11-JUL-17:15
EnergyTransfer:Zone:T N2 APARTMENT 25.00 0.01 19-SEP-16:00 2970.95 29-JAN-00:15
Heating:EnergyTransfer:Zone:T N2 APARTMENT 19.28 0.00 18-MAR-11:45 2970.95 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 5.72 0.00 01-JAN-00:15 1762.72 11-JUL-17:15
EnergyTransfer:Zone:T S1 APARTMENT 25.10 0.45 14-FEB-13:00 2868.64 29-JAN-00:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 16.43 0.00 09-FEB-11:30 2868.64 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 8.67 0.00 01-JAN-00:15 2653.82 23-JUL-13:45
EnergyTransfer:Zone:T S2 APARTMENT 25.14 0.75 25-SEP-21:30 2869.00 29-JAN-00:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 16.42 0.00 09-FEB-11:30 2869.00 29-JAN-00:15
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 8.72 0.00 01-JAN-00:15 2668.26 23-JUL-13:45
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 984.44 0.00 02-JUN-01:45 111751.53 29-JAN-00:15
HeatingCoils:EnergyTransfer 785.74 0.00 17-APR-14:00 111751.53 29-JAN-00:15
CoolingCoils:EnergyTransfer 198.70 0.00 01-JAN-00:15 67288.74 29-JUL-16:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 12.203 -4.989 0.000 0.000 3.924 2.413 12.213 9.390 0.000 0.008 0.000 0.000 -13.793 0.000 -4.195 -17.173
G NW APARTMENT 14.335 -3.478 0.000 0.000 3.945 2.413 12.213 3.842 0.000 0.008 0.000 0.000 -14.808 0.000 -4.131 -14.339
OFFICE 1.687 -21.964 0.000 0.000 0.554 21.914 7.534 10.581 0.000 0.005 0.000 0.000 -12.469 0.000 -3.265 -4.577
G NE APARTMENT 14.041 -4.052 0.000 0.000 3.950 2.413 12.213 4.829 0.000 0.008 0.000 0.000 -14.451 0.000 -4.133 -14.818
G N1 APARTMENT 8.210 -3.832 0.000 0.000 3.950 2.413 12.213 1.508 0.000 0.007 0.000 0.000 -9.164 0.000 -2.718 -12.586
G N2 APARTMENT 8.199 -3.856 0.000 0.000 3.950 2.413 12.213 1.507 0.000 0.007 0.000 0.000 -9.164 0.000 -2.719 -12.549
G S1 APARTMENT 6.434 -5.320 0.000 0.000 3.920 2.413 12.213 7.275 0.000 0.007 0.000 0.000 -8.326 0.000 -2.791 -15.825
G S2 APARTMENT 7.793 -5.172 0.000 0.000 3.920 2.413 12.213 7.277 0.000 0.007 0.000 0.000 -8.305 0.000 -2.791 -17.355
M SW APARTMENT 14.655 -24.451 0.000 0.000 3.838 2.413 12.213 9.046 0.000 0.010 2.646 0.000 -14.403 0.000 -5.968 -0.000
M NW APARTMENT 19.140 -16.489 0.000 0.000 3.867 2.413 12.213 3.524 0.000 0.011 0.000 0.000 -15.377 0.000 -5.926 -3.376
M SE APARTMENT 14.332 -26.659 0.000 0.000 3.838 2.413 12.213 10.093 0.000 0.010 3.853 0.000 -14.124 0.000 -5.970 -0.001
M NE APARTMENT 18.545 -18.541 0.000 0.000 3.870 2.413 12.213 4.495 0.000 0.011 0.001 0.000 -15.013 0.000 -5.924 -2.069
M N1 APARTMENT 5.887 -17.946 0.000 0.000 3.862 2.413 12.213 1.314 0.000 0.009 5.718 0.000 -9.581 0.000 -3.888 -0.001
M N2 APARTMENT 5.862 -18.036 0.000 0.000 3.862 2.413 12.213 1.313 0.000 0.009 5.834 0.000 -9.582 0.000 -3.888 -0.000
M S1 APARTMENT 3.670 -27.783 0.000 0.000 3.824 2.413 12.213 7.058 0.000 0.009 11.243 0.000 -8.724 0.000 -3.921 -0.000
M S2 APARTMENT 3.665 -27.899 0.000 0.000 3.823 2.413 12.213 7.057 0.000 0.009 11.366 0.000 -8.725 0.000 -3.922 -0.001
T SW APARTMENT 24.246 -8.599 0.000 0.000 3.895 2.413 12.213 9.050 0.000 0.014 0.000 0.000 -13.819 0.000 -7.613 -21.799
T NW APARTMENT 27.396 -5.731 0.000 0.000 3.917 2.413 12.213 3.553 0.000 0.014 0.000 0.000 -14.796 0.000 -7.561 -21.419
T SE APARTMENT 23.892 -9.380 0.000 0.000 3.894 2.413 12.213 10.127 0.000 0.014 0.000 0.000 -13.581 0.000 -7.617 -21.974
T NE APARTMENT 26.972 -6.546 0.000 0.000 3.922 2.413 12.213 4.546 0.000 0.014 0.000 0.000 -14.460 0.000 -7.557 -21.517
T N1 APARTMENT 19.297 -5.673 0.000 0.000 3.919 2.413 12.213 1.350 0.000 0.012 0.000 0.000 -9.171 0.000 -4.884 -19.475
T N2 APARTMENT 19.281 -5.717 0.000 0.000 3.919 2.413 12.213 1.348 0.000 0.012 0.000 0.000 -9.171 0.000 -4.885 -19.413
T S1 APARTMENT 16.431 -8.668 0.000 0.000 3.885 2.413 12.213 7.073 0.000 0.012 0.000 0.000 -8.367 0.000 -4.931 -20.062
T S2 APARTMENT 16.419 -8.723 0.000 0.000 3.885 2.413 12.213 7.071 0.000 0.012 0.000 0.000 -8.367 0.000 -4.932 -19.990
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.015 0.000 0.000 0.000 0.000 -1.601 0.000 -1.202 -14.281
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.077 0.000 0.007 21.497 0.000 -4.357 0.000 -40.559 -0.001
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.015 0.000 0.000 0.000 0.000 -1.748 0.000 -0.984 -14.353
Total Facility 332.592 -289.501 0.000 0.000 90.133 128.627 294.692 134.334 0.000 0.243 62.158 0.000 -285.449 0.000 -158.875 -308.957


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 11-AUG-16:15 0.00 -1693.00 0.00 0.00 84.75 144.04 588.62 2156.61 0.00 48.71 0.00 0.00 0.00 0.00 0.00 -1329.74
G NW APARTMENT 11-JUL-17:45 0.00 -1372.39 0.00 0.00 141.81 194.45 588.62 1635.87 0.00 74.25 0.00 0.00 0.00 0.00 0.00 -1262.61
OFFICE 10-AUG-13:30 0.00 -3248.89 0.00 0.00 67.31 1622.34 544.92 2557.77 0.00 0.00 0.00 0.00 0.00 0.00 -16.10 -1527.35
G NE APARTMENT 11-JUL-17:15 0.00 -1009.72 0.00 0.00 141.81 194.45 588.62 412.89 0.00 74.88 0.00 0.00 0.00 0.00 0.00 -402.93
G N1 APARTMENT 25-OCT-18:20 0.00 -873.29 0.00 0.00 165.01 230.46 547.42 0.00 0.00 0.00 425.95 0.00 -460.70 0.00 -34.85 0.00
G N2 APARTMENT 25-OCT-18:20 0.00 -874.95 0.00 0.00 165.01 230.46 547.42 0.00 0.00 0.00 427.61 0.00 -460.70 0.00 -34.85 0.00
G S1 APARTMENT 11-AUG-15:15 0.00 -1264.51 0.00 0.00 48.90 100.83 470.90 1711.94 0.00 10.29 0.00 0.00 0.00 0.00 0.00 -1078.34
G S2 APARTMENT 11-AUG-15:15 0.00 -1246.15 0.00 0.00 48.90 100.83 470.90 1712.20 0.00 10.29 0.00 0.00 0.00 0.00 0.00 -1096.96
M SW APARTMENT 11-AUG-16:15 0.00 -5092.44 0.00 0.00 84.76 144.04 588.62 2136.70 0.00 66.36 2071.97 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 11-JUL-18:15 0.00 -4159.67 0.00 0.00 141.81 230.46 547.42 1470.68 0.00 100.85 1668.45 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 22-JUL-11:30 0.00 -4884.63 0.00 0.00 40.75 28.81 406.15 2744.84 0.00 36.25 1627.83 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 11-JUL-17:15 0.00 -3402.25 0.00 0.00 141.81 194.45 588.62 395.62 0.00 102.00 1979.75 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 11-JUL-19:00 0.00 -2770.14 0.00 0.00 141.80 230.46 547.42 262.01 0.00 84.08 1504.37 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 11-JUL-19:00 0.00 -2762.18 0.00 0.00 141.80 230.46 547.42 262.05 0.00 84.08 1496.37 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 11-AUG-15:15 0.00 -4033.22 0.00 0.00 48.90 100.83 470.90 1698.77 0.00 13.65 1700.18 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 11-AUG-15:15 0.00 -4041.37 0.00 0.00 48.90 100.83 470.90 1698.71 0.00 13.65 1708.39 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 29-JUL-15:30 0.00 -3166.27 0.00 0.00 48.90 100.83 470.90 2487.83 0.00 91.04 0.00 0.00 0.00 0.00 0.00 -33.22
T NW APARTMENT 11-JUL-17:45 0.00 -2638.86 0.00 0.00 141.81 194.45 588.62 1592.89 0.00 128.11 0.00 0.00 0.00 0.00 0.00 -7.02
T SE APARTMENT 22-JUL-11:45 0.00 -3045.17 0.00 0.00 40.75 28.81 406.15 2537.02 0.00 69.32 0.00 0.00 0.00 0.00 0.00 -36.88
T NE APARTMENT 11-JUL-17:15 0.00 -2052.37 0.00 0.00 141.81 194.45 588.62 380.66 0.00 129.37 617.46 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 11-JUL-17:15 0.00 -1771.18 0.00 0.00 141.81 194.45 588.62 234.65 0.00 114.60 497.05 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 11-JUL-17:15 0.00 -1762.43 0.00 0.00 141.81 194.45 588.62 234.77 0.00 114.60 488.18 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 23-JUL-13:45 0.00 -2653.62 0.00 0.00 40.75 28.81 382.60 2126.17 0.00 15.56 59.72 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 23-JUL-13:45 0.00 -2668.06 0.00 0.00 40.75 28.81 382.60 2125.98 0.00 15.56 74.35 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-JUL-17:15 0.00 -56012.02 0.00 0.00 3261.52 6475.86 14071.03 17975.34 0.00 2106.48 12163.58 0.00 0.00 0.00 -41.80 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 29-JAN-00:15 2264.26 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1122.47 0.00 -1118.80 -491.94
G NW APARTMENT 29-JAN-00:15 2344.93 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1144.65 0.00 -1118.80 -550.43
OFFICE 24-DEC-07:01 6929.63 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -459.70 0.00 -154.77 -6889.72
G NE APARTMENT 29-JAN-00:15 2356.44 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1161.58 0.00 -1118.80 -545.01
G N1 APARTMENT 29-JAN-00:15 1456.40 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -704.32 0.00 -674.83 -546.20
G N2 APARTMENT 12-OCT-16:01 1546.87 0.00 0.00 0.00 98.71 144.04 588.62 0.00 0.00 0.00 0.00 0.00 -314.23 0.00 -81.69 -1982.32
G S1 APARTMENT 16-OCT-06:01 1604.84 0.00 0.00 0.00 161.43 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -349.29 0.00 -75.55 -1817.66
G S2 APARTMENT 15-OCT-06:01 1620.71 0.00 0.00 0.00 161.44 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -343.26 0.00 -83.84 -1831.28
M SW APARTMENT 29-JAN-00:15 4728.36 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1147.52 0.00 -1608.50 -2441.29
M NW APARTMENT 29-JAN-00:15 4993.41 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1171.90 0.00 -1608.50 -2681.96
M SE APARTMENT 29-JAN-00:15 4752.62 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1166.58 0.00 -1608.50 -2446.50
M NE APARTMENT 29-JAN-00:15 5018.35 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1190.86 0.00 -1608.50 -2687.94
M N1 APARTMENT 14-FEB-08:01 3730.20 0.00 0.00 0.00 74.13 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -543.46 0.00 0.00 -3692.57
M N2 APARTMENT 09-DEC-18:07 3471.49 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -591.22 0.00 -32.82 -3795.54
M S1 APARTMENT 13-JAN-18:07 3268.89 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -579.73 0.00 0.00 -3637.25
M S2 APARTMENT 13-JAN-18:07 3265.22 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -579.73 0.00 0.00 -3633.58
T SW APARTMENT 29-JAN-00:15 4238.99 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1121.92 0.00 -2129.39 -1456.63
T NW APARTMENT 29-JAN-00:15 4337.22 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1147.53 0.00 -2129.39 -1529.26
T SE APARTMENT 29-JAN-00:15 4256.02 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1141.68 0.00 -2129.39 -1453.90
T NE APARTMENT 29-JAN-00:15 4354.22 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -1167.23 0.00 -2129.39 -1526.56
T N1 APARTMENT 29-JAN-00:15 2970.58 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -707.92 0.00 -1284.44 -1447.18
T N2 APARTMENT 29-JAN-00:15 2970.94 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -707.91 0.00 -1284.44 -1447.54
T S1 APARTMENT 29-JAN-00:15 2868.64 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -682.00 0.00 -1284.44 -1371.15
T S2 APARTMENT 29-JAN-00:15 2869.00 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -682.00 0.00 -1284.44 -1371.51
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 29-JAN-00:15 71902.86 0.00 0.00 0.00 4362.43 2334.74 6261.33 0.00 0.00 0.00 0.00 0.00 -22589.90 0.00 -31808.10 -30463.36



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Sec1.1A-General Information

Data
Weather File Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 27.25
Number of hours cooling loads not met 0.00
Number of hours not met 27.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 9689.08 0.00 0.00 0.00 0.00
Exterior Lighting 39.11 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 982.18 139689.41 0.00 0.00
Space Cooling 49.81 14959.49 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 214.76 6809.89 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 500.66 31184.17 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 23563.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1480.75   982.18   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1480.75
Natural Gas 0.00 982.18
Additional 0.00 0.00
Total 511.42 2462.93


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 15.89
Fans-Interior 68.51
Service Water Heating 159.72
Receptacle Equipment 163.15
Miscellaneous 12.48
Subtotal 472.39


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 313.33
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 313.33


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.70
Space Heating 39.88
Space Cooling 2.02
Fans-Interior 8.72
Service Water Heating 20.33
Receptacle Equipment 20.76
Miscellaneous 1.59



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.166650
G NW APARTMENT DIRECT AIR 0.134581
OFFICE DIRECT AIR 0.422541
G NE APARTMENT DIRECT AIR 0.093014
G N1 APARTMENT DIRECT AIR 0.082285
G N2 APARTMENT DIRECT AIR 0.081185
G S1 APARTMENT DIRECT AIR 0.125538
G S2 APARTMENT DIRECT AIR 0.128600
M SW APARTMENT DIRECT AIR 0.493165
M NW APARTMENT DIRECT AIR 0.402451
M SE APARTMENT DIRECT AIR 0.468381
M NE APARTMENT DIRECT AIR 0.314931
M N1 APARTMENT DIRECT AIR 0.263324
M N2 APARTMENT DIRECT AIR 0.261280
M S1 APARTMENT DIRECT AIR 0.385218
M S2 APARTMENT DIRECT AIR 0.386497
T SW APARTMENT DIRECT AIR 0.313175
T NW APARTMENT DIRECT AIR 0.244270
T SE APARTMENT DIRECT AIR 0.298984
T NE APARTMENT DIRECT AIR 0.187413
T N1 APARTMENT DIRECT AIR 0.153311
T N2 APARTMENT DIRECT AIR 0.151168
T S1 APARTMENT DIRECT AIR 0.260360
T S2 APARTMENT DIRECT AIR 0.261345


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.166650
SPLIT GNW MAIN BRANCH 0.134581
SPLIT OFFICE MAIN BRANCH 0.422541
SPLIT GNE MAIN BRANCH 0.093014
SPLIT GN1 MAIN BRANCH 0.082285
SPLIT GN2 MAIN BRANCH 0.081185
SPLIT GS1 MAIN BRANCH 0.125538
SPLIT GS2 MAIN BRANCH 0.128600
SPLIT MSW MAIN BRANCH 0.493165
SPLIT MNW MAIN BRANCH 0.402451
SPLIT MSE MAIN BRANCH 0.468381
SPLIT MNE MAIN BRANCH 0.314931
SPLIT MN1 MAIN BRANCH 0.263324
SPLIT MN2 MAIN BRANCH 0.261280
SPLIT MS1 MAIN BRANCH 0.385218
SPLIT MS2 MAIN BRANCH 0.386497
SPLIT TSW MAIN BRANCH 0.313175
SPLIT TNW MAIN BRANCH 0.244270
SPLIT TSE MAIN BRANCH 0.298984
SPLIT TNE MAIN BRANCH 0.187413
SPLIT TN1 MAIN BRANCH 0.153311
SPLIT TN2 MAIN BRANCH 0.151168
SPLIT TS1 MAIN BRANCH 0.260360
SPLIT TS2 MAIN BRANCH 0.261345


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.166650
SPLIT GNW 0.134581
SPLIT OFFICE 0.422541
SPLIT GNE 0.093014
SPLIT GN1 0.082285
SPLIT GN2 0.081185
SPLIT GS1 0.125538
SPLIT GS2 0.128600
SPLIT MSW 0.493165
SPLIT MNW 0.402451
SPLIT MSE 0.468381
SPLIT MNE 0.314931
SPLIT MN1 0.263324
SPLIT MN2 0.261280
SPLIT MS1 0.385218
SPLIT MS2 0.386497
SPLIT TSW 0.313175
SPLIT TNW 0.244270
SPLIT TSE 0.298984
SPLIT TNE 0.187413
SPLIT TN1 0.153311
SPLIT TN2 0.151168
SPLIT TS1 0.260360
SPLIT TS2 0.261345


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.166650 0.026898
SPLIT GNW OA CONTROLLER 0.134581 0.025953
SPLIT OFFICE OA CONTROLLER 0.422541 0.038104
SPLIT GNE OA CONTROLLER 0.093014 0.025953
SPLIT GN1 OA CONTROLLER 0.082285 0.025953
SPLIT GN2 OA CONTROLLER 0.081185 0.025953
SPLIT GS1 OA CONTROLLER 0.125538 0.025953
SPLIT GS2 OA CONTROLLER 0.128600 0.025953
SPLIT MSW OA CONTROLLER 0.493165 0.051906
SPLIT MNW OA CONTROLLER 0.402451 0.051906
SPLIT MSE OA CONTROLLER 0.468381 0.051906
SPLIT MNE OA CONTROLLER 0.314931 0.051906
SPLIT MN1 OA CONTROLLER 0.263324 0.051906
SPLIT MN2 OA CONTROLLER 0.261280 0.051906
SPLIT MS1 OA CONTROLLER 0.385218 0.051906
SPLIT MS2 OA CONTROLLER 0.386497 0.051906
SPLIT TSW OA CONTROLLER 0.313175 0.025953
SPLIT TNW OA CONTROLLER 0.244270 0.025953
SPLIT TSE OA CONTROLLER 0.298984 0.025953
SPLIT TNE OA CONTROLLER 0.187413 0.025953
SPLIT TN1 OA CONTROLLER 0.153311 0.025953
SPLIT TN2 OA CONTROLLER 0.151168 0.025953
SPLIT TS1 OA CONTROLLER 0.260360 0.025953
SPLIT TS2 OA CONTROLLER 0.261345 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.166650 2758.65 0.798655
SPLIT GNW COOLING COIL 0.134581 2227.79 0.798655
SPLIT OFFICE COOLING COIL 0.422541 6994.56 0.798655
SPLIT GNE COOLING COIL 0.093014 1539.71 0.798655
SPLIT GN1 COOLING COIL 0.082285 1362.11 0.798655
SPLIT GN2 COOLING COIL 0.081185 1343.90 0.798655
SPLIT GS1 COOLING COIL 0.125538 2078.10 0.798655
SPLIT GS2 COOLING COIL 0.128600 2128.78 0.798655
SPLIT MSW COOLING COIL 0.493165 8163.63 0.798655
SPLIT MNW COOLING COIL 0.402451 6662.00 0.798655
SPLIT MSE COOLING COIL 0.468381 7753.37 0.798655
SPLIT MNE COOLING COIL 0.314931 5213.23 0.798655
SPLIT MN1 COOLING COIL 0.263324 4358.95 0.798655
SPLIT MN2 COOLING COIL 0.261280 4325.12 0.798655
SPLIT MS1 COOLING COIL 0.385218 6376.73 0.798655
SPLIT MS2 COOLING COIL 0.386497 6397.90 0.798655
SPLIT TSW COOLING COIL 0.313175 5184.17 0.798655
SPLIT TNW COOLING COIL 0.244270 4043.53 0.798655
SPLIT TSE COOLING COIL 0.298984 4949.24 0.798655
SPLIT TNE COOLING COIL 0.187413 3102.35 0.798655
SPLIT TN1 COOLING COIL 0.153311 2537.85 0.798655
SPLIT TN2 COOLING COIL 0.151168 2502.36 0.798655
SPLIT TS1 COOLING COIL 0.260360 4309.88 0.798655
SPLIT TS2 COOLING COIL 0.261345 4326.19 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.166650 0.166650 0.166650 0.166650 4380.83 2758.65 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.134581 0.134581 0.134581 0.134581 4322.48 2227.79 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.422541 0.422541 0.422541 0.422541 7635.65 6994.56 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.093014 0.093014 0.093014 0.093014 4328.50 1539.71 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.082285 0.082285 0.082285 0.082285 3561.71 1362.11 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.081185 0.081185 0.081185 0.081185 3561.83 1343.90 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.125538 0.125538 0.125538 0.125538 3552.15 2078.10 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.128600 0.128600 0.128600 0.128600 3692.52 2128.78 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.493165 0.493165 0.493165 0.493165 7564.91 8163.63 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.402451 0.402451 0.402451 0.402451 7593.70 6662.00 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.468381 0.468381 0.468381 0.468381 7580.91 7753.37 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.314931 0.314931 0.314931 0.314931 7609.73 5213.23 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.263324 0.263324 0.263324 0.263324 5818.98 4358.95 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.261280 0.261280 0.261280 0.261280 5819.35 4325.12 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.385218 0.385218 0.385218 0.385218 5793.87 6376.73 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.386497 0.386497 0.386497 0.386497 5794.23 6397.90 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.313175 0.313175 0.313175 0.313175 5899.17 5184.17 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.244270 0.244270 0.244270 0.244270 5917.55 4043.53 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.298984 0.298984 0.298984 0.298984 5907.98 4949.24 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.187413 0.187413 0.187413 0.187413 5926.38 3102.35 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.153311 0.153311 0.153311 0.153311 5041.35 2537.85 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.151168 0.151168 0.151168 0.151168 5041.56 2502.36 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.260360 0.260360 0.260360 0.260360 5021.53 4309.88 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.261345 0.261345 0.261345 0.261345 5021.73 4326.19 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.166650
SPLIT GNW SUPPLY FAN 0.134581
SPLIT OFFICE SUPPLY FAN 0.422541
SPLIT GNE SUPPLY FAN 0.093014
SPLIT GN1 SUPPLY FAN 0.082285
SPLIT GN2 SUPPLY FAN 0.081185
SPLIT GS1 SUPPLY FAN 0.125538
SPLIT GS2 SUPPLY FAN 0.128600
SPLIT MSW SUPPLY FAN 0.493165
SPLIT MNW SUPPLY FAN 0.402451
SPLIT MSE SUPPLY FAN 0.468381
SPLIT MNE SUPPLY FAN 0.314931
SPLIT MN1 SUPPLY FAN 0.263324
SPLIT MN2 SUPPLY FAN 0.261280
SPLIT MS1 SUPPLY FAN 0.385218
SPLIT MS2 SUPPLY FAN 0.386497
SPLIT TSW SUPPLY FAN 0.313175
SPLIT TNW SUPPLY FAN 0.244270
SPLIT TSE SUPPLY FAN 0.298984
SPLIT TNE SUPPLY FAN 0.187413
SPLIT TN1 SUPPLY FAN 0.153311
SPLIT TN2 SUPPLY FAN 0.151168
SPLIT TS1 SUPPLY FAN 0.260360
SPLIT TS2 SUPPLY FAN 0.261345


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 4380.83
SPLIT GNW HEATING COIL 4322.48
SPLIT OFFICE HEATING COIL 7635.65
SPLIT GNE HEATING COIL 4328.50
SPLIT GN1 HEATING COIL 3561.71
SPLIT GN2 HEATING COIL 3561.83
SPLIT GS1 HEATING COIL 3552.15
SPLIT GS2 HEATING COIL 3692.52
SPLIT MSW HEATING COIL 7564.91
SPLIT MNW HEATING COIL 7593.70
SPLIT MSE HEATING COIL 7580.91
SPLIT MNE HEATING COIL 7609.73
SPLIT MN1 HEATING COIL 5818.98
SPLIT MN2 HEATING COIL 5819.35
SPLIT MS1 HEATING COIL 5793.87
SPLIT MS2 HEATING COIL 5794.23
SPLIT TSW HEATING COIL 5899.17
SPLIT TNW HEATING COIL 5917.55
SPLIT TSE HEATING COIL 5907.98
SPLIT TNE HEATING COIL 5926.38
SPLIT TN1 HEATING COIL 5041.35
SPLIT TN2 HEATING COIL 5041.56
SPLIT TS1 HEATING COIL 5021.53
SPLIT TS2 HEATING COIL 5021.73



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:32

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.07 0.73
May 22.69 10.60
June 24.13 15.96
July 24.26 16.86
August 24.05 14.24
September 22.90 6.72
October 21.74 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.53 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.26 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.78 0.73
May 22.23 10.60
June 24.06 15.96
July 24.22 16.86
August 23.86 14.24
September 22.46 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.41 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.22 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 17.45 -17.6
February 17.88 -15.4
March 18.72 -10.3
April 21.02 0.73
May 22.92 10.60
June 23.87 15.96
July 23.89 16.86
August 23.82 14.24
September 23.09 6.72
October 20.09 -3.1
November 17.49 -17.6
December 17.29 -19.3
     
Annual Sum or Average 20.64 -1.4
Minimum of Months 17.29 -19.3
Maximum of Months 23.89 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.74 0.73
May 22.31 10.60
June 24.07 15.96
July 24.20 16.86
August 23.86 14.24
September 22.41 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.40 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.20 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.73 0.73
May 22.05 10.60
June 23.98 15.96
July 24.19 16.86
August 23.84 14.24
September 22.51 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.38 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.72 0.73
May 22.06 10.60
June 23.99 15.96
July 24.19 16.86
August 23.84 14.24
September 22.51 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.38 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.03 0.73
May 22.61 10.60
June 24.14 15.96
July 24.28 16.86
August 24.13 14.24
September 23.11 6.72
October 21.76 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.55 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.28 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.02 0.73
May 22.63 10.60
June 24.14 15.96
July 24.27 16.86
August 24.12 14.24
September 23.12 6.72
October 21.77 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.55 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.27 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.79 -10.3
April 23.07 0.73
May 24.25 10.60
June 24.39 15.96
July 24.40 16.86
August 24.36 14.24
September 23.75 6.72
October 22.06 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.91 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.36 0.73
May 24.12 10.60
June 24.39 15.96
July 24.40 16.86
August 24.31 14.24
September 23.31 6.72
October 21.76 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.77 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.81 -10.3
April 23.07 0.73
May 24.26 10.60
June 24.39 15.96
July 24.40 16.86
August 24.37 14.24
September 23.78 6.72
October 22.11 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.92 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.30 0.73
May 24.12 10.60
June 24.39 15.96
July 24.40 16.86
August 24.33 14.24
September 23.32 6.72
October 21.76 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.77 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.30 0.73
May 24.20 10.60
June 24.40 15.96
July 24.40 16.86
August 24.34 14.24
September 23.50 6.72
October 21.82 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.80 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.29 0.73
May 24.20 10.60
June 24.40 15.96
July 24.40 16.86
August 24.34 14.24
September 23.50 6.72
October 21.82 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.80 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.87 -10.3
April 23.26 0.73
May 24.32 10.60
June 24.40 15.96
July 24.40 16.86
August 24.38 14.24
September 23.99 6.72
October 22.29 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.98 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.88 -10.3
April 23.26 0.73
May 24.33 10.60
June 24.40 15.96
July 24.40 16.86
August 24.38 14.24
September 23.99 6.72
October 22.30 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.99 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.40 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.77 -10.3
April 22.58 0.73
May 23.58 10.60
June 24.29 15.96
July 24.35 16.86
August 24.12 14.24
September 22.75 6.72
October 21.79 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.67 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.35 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.12 0.73
May 23.36 10.60
June 24.28 15.96
July 24.32 16.86
August 23.94 14.24
September 22.28 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.55 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.78 -10.3
April 22.60 0.73
May 23.67 10.60
June 24.30 15.96
July 24.34 16.86
August 24.14 14.24
September 22.79 6.72
October 21.80 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.69 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.08 0.73
May 23.46 10.60
June 24.26 15.96
July 24.29 16.86
August 23.92 14.24
September 22.27 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.55 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.03 0.73
May 23.37 10.60
June 24.30 15.96
July 24.32 16.86
August 23.94 14.24
September 22.23 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.54 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.03 0.73
May 23.39 10.60
June 24.30 15.96
July 24.32 16.86
August 23.94 14.24
September 22.23 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.54 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.78 -10.3
April 22.62 0.73
May 23.70 10.60
June 24.33 15.96
July 24.37 16.86
August 24.19 14.24
September 22.88 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.72 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.37 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.79 -10.3
April 22.63 0.73
May 23.71 10.60
June 24.33 15.96
July 24.37 16.86
August 24.19 14.24
September 22.89 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.72 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.37 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.62 -17.6
February 19.97 -15.4
March 20.72 -10.3
April 22.61 0.73
May 24.95 10.60
June 26.36 15.96
July 26.44 16.86
August 25.73 14.24
September 23.22 6.72
October 21.20 -3.1
November 19.75 -17.6
December 19.48 -19.3
     
Annual Sum or Average 22.52 -1.4
Minimum of Months 19.48 -19.3
Maximum of Months 26.44 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 16.87 -17.6
February 17.34 -15.4
March 18.22 -10.3
April 20.27 0.73
May 22.32 10.60
June 24.78 15.96
July 25.19 16.86
August 24.62 14.24
September 22.73 6.72
October 19.61 -3.1
November 17.11 -17.6
December 16.68 -19.3
     
Annual Sum or Average 20.50 -1.4
Minimum of Months 16.68 -19.3
Maximum of Months 25.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:32

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.36 -17.6
February 22.66 -15.4
March 23.14 -10.3
April 24.62 0.73
May 26.51 10.60
June 26.95 15.96
July 26.95 16.86
August 26.73 14.24
September 25.66 6.72
October 23.44 -3.1
November 22.51 -17.6
December 22.28 -19.3
     
Annual Sum or Average 24.49 -1.4
Minimum of Months 22.28 -19.3
Maximum of Months 26.95 16.86



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:32

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.125350E+12 77005.147 30-JAN-18:45 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32657.744 0.000 0.000 0.000
February 0.112382E+12 77005.192 26-FEB-18:45 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32657.788 0.000 0.000 0.000
March 0.123549E+12 77004.904 01-MAR-18:45 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32657.501 0.000 0.000 0.000
April 0.119928E+12 79322.955 22-APR-17:30 8572.775 26456.413 6809.886 0.000 5186.635 0.000 0.000 0.000 0.000 0.000 0.000 32297.247 0.000 0.000 0.000
May 0.127552E+12 78996.594 10-MAY-17:15 8572.775 26456.413 6809.886 0.000 8343.651 0.000 0.000 0.000 0.000 0.000 0.000 28813.869 0.000 0.000 0.000
June 0.128439E+12 83869.071 29-JUN-17:30 8572.775 26456.413 6809.886 0.000 14035.524 0.000 0.000 0.000 0.000 0.000 0.000 27994.473 0.000 0.000 0.000
July 0.133482E+12 86205.636 29-JUL-18:15 9689.078 23563.017 6809.886 0.000 14959.487 0.000 0.000 0.000 0.000 0.000 0.000 31184.169 0.000 0.000 0.000
August 0.128421E+12 83138.732 23-AUG-17:00 8572.775 26456.413 6809.886 0.000 12321.832 0.000 0.000 0.000 0.000 0.000 0.000 28977.827 0.000 0.000 0.000
September 0.117086E+12 74620.499 01-SEP-17:15 8572.775 26456.413 6809.886 0.000 4654.121 0.000 0.000 0.000 0.000 0.000 0.000 28127.305 0.000 0.000 0.000
October 0.120651E+12 74727.816 31-OCT-17:00 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 30380.412 0.000 0.000 0.000
November 0.118853E+12 76888.186 28-NOV-18:45 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32540.782 0.000 0.000 0.000
December 0.125060E+12 77002.596 31-DEC-18:15 8572.775 26456.413 6809.886 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32655.193 0.000 0.000 0.000
                                     
Annual Sum or Average 0.148075E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.112382E+12 74620.499   8572.775 23563.017 6809.886 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 27994.473 0.000 0.000 0.000
Maximum of Months 0.133482E+12 86205.636   9689.078 26456.413 6809.886 0.000 14959.487 2508.330 0.000 0.000 0.000 0.000 0.000 32657.788 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:32

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.196668E+12 139689.409 29-JAN-00:15 139689.409 0.000 0.000 0.000 0.000 0.000 139689.409
February 0.150126E+12 120183.943 25-FEB-00:00 120183.943 0.000 0.000 0.000 0.000 0.000 120183.943
March 0.119104E+12 105638.311 02-MAR-04:00 105638.311 0.000 0.000 0.000 0.000 0.000 105638.311
April 0.430948E+11 83010.301 03-APR-02:00 83010.301 0.000 0.000 0.000 0.000 0.000 83010.301
May 0.362246E+10 19557.694 28-MAY-02:00 19557.694 0.000 0.000 0.000 0.000 0.000 19557.694
June 0.000 0.000 01-JUN-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.492991E+09 10497.026 31-AUG-03:00 10497.026 0.000 0.000 0.000 0.000 0.000 10497.026
September 0.889822E+10 32057.316 30-SEP-04:00 32057.316 0.000 0.000 0.000 0.000 0.000 32057.316
October 0.809562E+11 83779.090 27-OCT-03:00 83779.090 0.000 0.000 0.000 0.000 0.000 83779.090
November 0.172086E+12 111738.775 29-NOV-07:00 111738.775 0.000 0.000 0.000 0.000 0.000 111738.775
December 0.207128E+12 119594.006 15-DEC-09:15 119594.006 0.000 0.000 0.000 0.000 0.000 119594.006
                     
Annual Sum or Average 0.982176E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.207128E+12 139689.409   139689.409 0.000 0.000 0.000 0.000 0.000 139689.409