Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Tampa-MacDill AFB FL USA TMY3 WMO#=747880

Simulation Timestamp: 2018-10-19 09:20:30


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1587.90 506.57 562.29
Net Site Energy 1587.90 506.57 562.29
Total Source Energy 5000.96 1595.40 1770.89
Net Source Energy 5000.96 1595.40 1770.89


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 13.41 0.00 0.00 0.00 0.00
Cooling 323.87 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.40 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 214.43 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 320.37 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1574.49 13.41 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 13.41 0.00 0.00 0.00 0.00
Cooling General 323.87 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.40 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 214.43 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 320.37 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.38 0.00 0.00 0.00 0.00 0.00
HVAC 304.06 4.75 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 557.55 4.75 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.21 0.00 0.00 0.00 0.00 0.00
HVAC 273.93 4.28 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 502.29 4.28 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1574.49 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1574.49 100.00
     
Total On-Site and Utility Electric Sources 1574.49 100.00
Total Electricity End Uses 1574.49 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 18.50
Time Setpoint Not Met During Occupied Cooling 1.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 3455.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Weather File Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Latitude [deg] 27.85
Longitude [deg] -82.5
Elevation [m] 8.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 09-SEP-17:15 05-FEB-07:15 - - - 01-JAN-07:15
Heating 0.00 38133.26 0.00 0.00 0.00 0.00
Cooling 29077.82 0.00 0.00 0.00 0.00 0.00
Interior Lighting 8572.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 6799.41 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 18649.28 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 89555.69 38133.26 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 38133.26 0.00 0.00 0.00 0.00
Cooling General 29077.82 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7168.38 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1404.40 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 6799.41 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 18649.28 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 14.54 0.00 0.00 0.00
Cooling 1025.71 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 124.79 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 679.09 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1014.61 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4986.42 14.54 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 5.15 0.00 0.00 0.00
Cooling 363.21 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.19 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 240.47 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 359.28 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1765.75 5.15 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 5.15 0.00 0.00 0.00
Cooling 363.21 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.19 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 240.47 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 359.28 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1765.75 5.15 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 4.60 0.00 4.60 Wetbulb [C] 2.50 10.00
TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 33.90 7.90 25.10 Wetbulb [C] 3.10 270.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.55 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.55 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 4.600 0.293 0.130     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 4.600 0.293 0.130     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 4.600 0.293 0.130     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 4.600 0.293 0.130     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 4.600 0.293 0.130     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.72_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 4.600 0.293 0.130     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.72_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 4.600 0.293 0.130     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.72_SHGC_0.25 3.32 0.00 0.00 3.32 3.32 4.600 0.293 0.130     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 2.23 4.600 0.293 0.130     No M EWALL C 270.00 90.00 W
Total or Average           306.92 4.600 0.293 0.130              
North Total or Average           112.97 4.600 0.293 0.130              
Non-North Total or Average           193.95 4.600 0.293 0.130              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.69 83.69 39.40
Exterior Lighting Total 2508.33           39.40



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   4054.30 2923.03 1131.27 0.72 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   3846.04 2771.27 1074.77 0.72 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   8132.61 6291.51 1841.10 0.77 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   3282.18 2341.40 940.78 0.71 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2460.78 1687.47 773.31 0.69 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2449.65 1678.60 771.05 0.69 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2802.34 1928.13 874.21 0.69 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2843.95 1962.85 881.11 0.69 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   9396.21 6876.79 2519.42 0.73 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   8965.32 6542.51 2422.81 0.73 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   8534.78 6204.23 2330.55 0.73 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   7805.83 5646.03 2159.80 0.72 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5858.42 4108.09 1750.33 0.70 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5840.76 4093.95 1746.81 0.70 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6651.35 4672.74 1978.60 0.70 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6666.40 4684.83 1981.57 0.70 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5811.65 4306.40 1505.25 0.74 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   5509.95 4074.86 1435.09 0.74 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5255.92 3843.91 1412.01 0.73 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   4669.01 3407.56 1261.44 0.73 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3750.35 2668.73 1081.61 0.71 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3756.55 2671.17 1085.38 0.71 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4377.40 3166.85 1210.56 0.72 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4388.37 3175.47 1212.90 0.72 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3902.4 3.27 11.14 11.60 11.07
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3702.1 3.27 11.15 11.60 11.07
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 7773.5 3.17 10.82 11.25 10.59
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 3162.4 3.28 11.19 11.65 11.14
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2379.6 3.33 11.37 11.85 11.41
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2369.0 3.33 11.37 11.85 11.42
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2709.1 3.33 11.35 11.83 11.39
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2748.5 3.32 11.34 11.82 11.37
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 9031.1 3.25 11.07 11.53 10.97
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 8619.4 3.25 11.09 11.54 10.99
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 8208.5 3.25 11.11 11.56 11.01
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 7511.0 3.26 11.13 11.59 11.05
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5653.6 3.30 11.27 11.74 11.26
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5636.8 3.30 11.27 11.74 11.26
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 6417.7 3.30 11.26 11.73 11.25
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 6432.0 3.30 11.26 11.73 11.24
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5579.1 3.23 11.02 11.47 10.88
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 5290.5 3.23 11.03 11.48 10.90
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5052.0 3.25 11.08 11.53 10.97
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4488.8 3.25 11.09 11.54 10.99
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3614.3 3.28 11.20 11.67 11.16
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3620.5 3.28 11.21 11.67 11.16
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4212.0 3.26 11.13 11.58 11.05
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4222.5 3.26 11.13 11.58 11.04
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   1476.43 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   2771.00 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   2849.07 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   1902.87 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   1917.66 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   1902.87 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   1917.66 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   1433.51 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   1433.51 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   1424.54 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   1424.54 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 216.37 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 204.96 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.46 512.82 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 170.57 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 115.37 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 114.62 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.12 132.57 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.12 135.66 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.46 520.30 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.44 492.96 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.42 464.85 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.37 419.94 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 291.37 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 290.17 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 332.39 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 333.42 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 331.57 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 312.89 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 290.54 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 256.79 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 193.68 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 193.63 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.21 235.61 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.21 236.33 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2053.77 2464.53 0.161 0.193 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:45:00 32.95 0.01651
G NW APARTMENT 1945.49 2334.59 0.152 0.183 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
OFFICE 4633.70 5560.44 0.382 0.458 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 09:30:00 30.23 0.01651
G NE APARTMENT 1619.01 1942.81 0.127 0.152 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
G N1 APARTMENT 1095.18 1314.21 0.086 0.103 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
G N2 APARTMENT 1088.07 1305.68 0.085 0.102 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
G S1 APARTMENT 1258.41 1510.09 0.099 0.118 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
G S2 APARTMENT 1287.72 1545.27 0.101 0.121 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 33.70 0.01651
M SW APARTMENT 4938.61 5926.34 0.387 0.465 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:00:00 32.79 0.01651
M NW APARTMENT 4679.24 5615.09 0.367 0.440 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 32.40 0.01651
M SE APARTMENT 4412.27 5294.72 0.346 0.415 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
M NE APARTMENT 3985.95 4783.14 0.312 0.375 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 31.49 0.01651
M N1 APARTMENT 2765.75 3318.91 0.217 0.260 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
M N2 APARTMENT 2754.35 3305.22 0.216 0.259 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
M S1 APARTMENT 3155.09 3786.10 0.247 0.297 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
M S2 APARTMENT 3164.87 3797.84 0.248 0.298 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
T SW APARTMENT 3147.12 3776.54 0.247 0.296 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 33.27 0.01651
T NW APARTMENT 2969.79 3563.75 0.233 0.279 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:00:00 32.79 0.01651
T SE APARTMENT 2757.62 3309.14 0.216 0.259 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
T NE APARTMENT 2437.25 2924.70 0.191 0.229 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
T N1 APARTMENT 1838.38 2206.05 0.144 0.173 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 15:30:00 33.66 0.01651
T N2 APARTMENT 1837.96 2205.56 0.144 0.173 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 33.78 0.01651
T S1 APARTMENT 2236.42 2683.71 0.175 0.210 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 14:15:00 33.90 0.01651
T S2 APARTMENT 2243.23 2691.87 0.176 0.211 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.90 0.01651


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 641.90 770.28 0.018 0.027 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
G NW APARTMENT 650.05 780.07 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
OFFICE 1735.66 2082.79 0.048 0.057 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 4.60 0.00526
G NE APARTMENT 650.05 780.07 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
G N1 APARTMENT 320.53 384.64 0.009 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
G N2 APARTMENT 320.53 384.64 0.009 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
G S1 APARTMENT 313.87 376.65 0.009 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
G S2 APARTMENT 374.20 449.05 0.011 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M SW APARTMENT 1037.26 1244.72 0.030 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M NW APARTMENT 1061.59 1273.91 0.031 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M SE APARTMENT 1037.26 1244.72 0.030 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M NE APARTMENT 1061.59 1273.91 0.031 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M N1 APARTMENT 208.71 250.45 0.006 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M N2 APARTMENT 208.71 250.45 0.006 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M S1 APARTMENT 170.67 204.81 0.005 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
M S2 APARTMENT 170.67 204.81 0.005 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T SW APARTMENT 1155.44 1386.52 0.033 0.040 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T NW APARTMENT 1167.95 1401.54 0.034 0.040 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T SE APARTMENT 1155.44 1386.52 0.033 0.040 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T NE APARTMENT 1167.95 1401.54 0.034 0.040 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T N1 APARTMENT 758.51 910.22 0.022 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T N2 APARTMENT 758.51 910.22 0.022 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T S1 APARTMENT 745.51 894.61 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526
T S2 APARTMENT 745.51 894.61 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 04:00:00 4.60 0.00526


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.19 0.19 0.03 0.03
SPLIT GNW 0.18 0.18 0.03 0.03
SPLIT OFFICE 0.46 0.46 0.06 0.06
SPLIT GNE 0.15 0.15 0.03 0.03
SPLIT GN1 0.10 0.10 0.03 0.03
SPLIT GN2 0.10 0.10 0.03 0.03
SPLIT GS1 0.12 0.12 0.03 0.03
SPLIT GS2 0.12 0.12 0.03 0.03
SPLIT MSW 0.46 0.46 0.05 0.05
SPLIT MNW 0.44 0.44 0.05 0.05
SPLIT MSE 0.42 0.42 0.05 0.05
SPLIT MNE 0.37 0.37 0.05 0.05
SPLIT MN1 0.26 0.26 0.05 0.05
SPLIT MN2 0.26 0.26 0.05 0.05
SPLIT MS1 0.30 0.30 0.05 0.05
SPLIT MS2 0.30 0.30 0.05 0.05
SPLIT TSW 0.30 0.30 0.04 0.04
SPLIT TNW 0.28 0.28 0.04 0.04
SPLIT TSE 0.26 0.26 0.04 0.04
SPLIT TNE 0.23 0.23 0.04 0.04
SPLIT TN1 0.17 0.17 0.03 0.03
SPLIT TN2 0.17 0.17 0.03 0.03
SPLIT TS1 0.21 0.21 0.03 0.03
SPLIT TS2 0.21 0.21 0.03 0.03



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 5750.25 5125.25 2729.75
G NW APARTMENT 5593.75 5750.00 2969.25
OFFICE 817.00 824.75 5.75
G NE APARTMENT 5592.75 5676.75 2896.75
G N1 APARTMENT 5548.00 6135.75 3244.75
G N2 APARTMENT 5548.00 6132.50 3240.50
G S1 APARTMENT 5603.75 5311.75 2805.50
G S2 APARTMENT 5587.25 5417.00 2896.50
M SW APARTMENT 6968.00 1374.75 699.00
M NW APARTMENT 6598.75 2148.75 848.75
M SE APARTMENT 6947.00 1359.50 672.25
M NE APARTMENT 6570.50 2126.00 810.50
M N1 APARTMENT 6580.50 1759.75 592.00
M N2 APARTMENT 6578.75 1763.50 590.00
M S1 APARTMENT 6928.25 901.50 474.50
M S2 APARTMENT 6927.75 905.25 476.25
T SW APARTMENT 6673.50 2719.00 1375.75
T NW APARTMENT 6404.75 3329.00 1546.00
T SE APARTMENT 6669.25 2665.00 1320.25
T NE APARTMENT 6378.50 3367.50 1544.25
T N1 APARTMENT 6357.00 3188.25 1350.25
T N2 APARTMENT 6354.00 3182.50 1346.00
T S1 APARTMENT 6694.25 2437.25 1209.50
T S2 APARTMENT 6692.25 2441.00 1213.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 7144.25 6320.50 3455.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.00 0.00 1.00 0.00
G NW APARTMENT 1.00 0.00 1.00 0.00
OFFICE 0.25 0.00 0.00 0.00
G NE APARTMENT 2.25 0.00 2.25 0.00
G N1 APARTMENT 2.25 0.00 2.25 0.00
G N2 APARTMENT 2.75 0.00 2.75 0.00
G S1 APARTMENT 1.00 0.00 1.00 0.00
G S2 APARTMENT 0.75 0.00 0.75 0.00
M SW APARTMENT 0.00 0.00 0.00 0.00
M NW APARTMENT 0.00 0.00 0.00 0.00
M SE APARTMENT 0.00 0.00 0.00 0.00
M NE APARTMENT 0.25 0.00 0.25 0.00
M N1 APARTMENT 0.00 0.00 0.00 0.00
M N2 APARTMENT 0.00 0.00 0.00 0.00
M S1 APARTMENT 0.00 1.00 0.00 1.00
M S2 APARTMENT 0.00 1.00 0.00 1.00
T SW APARTMENT 0.25 0.00 0.25 0.00
T NW APARTMENT 3.25 0.00 3.25 0.00
T SE APARTMENT 0.50 0.00 0.50 0.00
T NE APARTMENT 3.75 0.00 3.75 0.00
T N1 APARTMENT 4.75 0.00 4.75 0.00
T N2 APARTMENT 4.50 0.00 4.50 0.00
T S1 APARTMENT 0.25 0.00 0.25 0.00
T S2 APARTMENT 1.50 0.00 1.50 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 18.50 1.00 18.50 1.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.369 0.075 0.000 0.093
G NW APARTMENT 1.71 2.50 268.97 0.356 0.075 0.000 0.092
OFFICE 0.94 1.00 268.97 0.521 0.087 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.356 0.075 0.000 0.092
G N1 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.090
G N2 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.090
G S1 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.093
G S2 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.093
M SW APARTMENT 1.71 2.50 268.97 0.356 0.108 0.000 0.113
M NW APARTMENT 1.71 2.50 268.97 0.356 0.108 0.000 0.113
M SE APARTMENT 1.71 2.50 268.97 0.356 0.108 0.000 0.113
M NE APARTMENT 1.71 2.50 268.97 0.356 0.108 0.000 0.113
M N1 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.113
M N2 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.113
M S1 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.113
M S2 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.113
T SW APARTMENT 1.71 2.50 268.97 0.356 0.142 0.000 0.136
T NW APARTMENT 1.71 2.50 268.97 0.355 0.142 0.000 0.136
T SE APARTMENT 1.71 2.50 268.97 0.356 0.142 0.000 0.136
T NE APARTMENT 1.71 2.50 268.97 0.355 0.142 0.000 0.136
T N1 APARTMENT 1.71 2.50 268.97 0.355 0.086 0.000 0.136
T N2 APARTMENT 1.71 2.50 268.97 0.355 0.086 0.000 0.136
T S1 APARTMENT 1.71 2.50 268.97 0.356 0.086 0.000 0.136
T S2 APARTMENT 1.71 2.50 268.97 0.356 0.086 0.000 0.136
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.354 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.500 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.364 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.366 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.366 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 320.37 0.00 01-JAN-00:15 31202.91 01-JAN-06:15
WaterSystems:Electricity 320.37 0.00 01-JAN-00:15 31202.91 01-JAN-06:15
Water Heater:WaterSystems:Electricity 320.37 0.00 01-JAN-00:15 31202.91 01-JAN-06:15
Fans:Electricity 214.43 6799.41 03-JAN-08:30 6799.41 03-JAN-17:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
ElectricityPurchased:Plant 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
Cogeneration:ElectricityPurchased 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
ElectricityNet:Plant 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
Cogeneration:ElectricityNet 1574.49 20169.70 03-JAN-03:45 89555.69 09-SEP-17:15
ExteriorLights:Electricity 39.40 0.00 01-JAN-07:30 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.40 0.00 01-JAN-07:30 2508.33 01-JAN-00:15
Electricity:HVAC 538.30 6799.41 04-JAN-08:30 37106.08 10-SEP-15:15
General:Fans:Electricity 214.43 6799.41 03-JAN-08:30 6799.41 03-JAN-17:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 323.87 0.00 03-JAN-01:30 30306.67 10-SEP-15:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 13.41 0.00 01-JAN-00:15 38133.26 05-FEB-07:15
Gas:HVAC 13.41 0.00 01-JAN-00:15 38133.26 05-FEB-07:15
Heating:Gas 13.41 0.00 01-JAN-00:15 38133.26 05-FEB-07:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 2127.35 1700.15 15-FEB-07:45 183107.17 10-SEP-15:15
EnergyTransfer:Building 780.53 1657.28 10-MAR-13:45 67000.40 10-SEP-15:15
EnergyTransfer:Zone:G SW APARTMENT 16.64 0.01 30-JAN-05:15 2384.65 30-AUG-16:15
Heating:EnergyTransfer 6.32 0.00 01-JAN-16:15 15838.15 05-FEB-07:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 0.29 0.00 01-JAN-00:45 717.36 05-FEB-07:00
Cooling:EnergyTransfer 774.21 727.89 10-MAR-12:30 67000.40 10-SEP-15:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 16.34 0.00 01-JAN-00:15 2384.65 30-AUG-16:15
EnergyTransfer:Zone:G NW APARTMENT 13.65 0.02 25-DEC-16:15 2170.39 07-JUL-16:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 0.71 0.00 01-JAN-04:15 868.83 05-FEB-08:30
Cooling:EnergyTransfer:Zone:G NW APARTMENT 12.93 0.00 01-JAN-00:15 2170.39 07-JUL-16:30
EnergyTransfer:Zone:OFFICE 31.90 0.15 05-DEC-19:45 3820.20 10-SEP-10:45
Heating:EnergyTransfer:Zone:OFFICE 0.25 0.00 01-JAN-00:15 1608.20 05-FEB-07:15
Cooling:EnergyTransfer:Zone:OFFICE 31.65 0.00 01-JAN-02:15 3820.20 10-SEP-10:45
EnergyTransfer:Zone:G NE APARTMENT 13.64 0.00 27-OCT-13:15 1729.64 10-SEP-09:45
Heating:EnergyTransfer:Zone:G NE APARTMENT 0.57 0.00 01-JAN-00:15 808.72 05-FEB-07:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 13.07 0.00 01-JAN-09:30 1729.64 10-SEP-09:45
EnergyTransfer:Zone:G N1 APARTMENT 10.39 0.00 13-DEC-06:30 1285.62 18-JUL-17:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.22 0.00 01-JAN-00:15 431.35 05-FEB-08:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 10.17 0.00 01-JAN-10:15 1285.62 18-JUL-17:30
EnergyTransfer:Zone:G N2 APARTMENT 10.39 0.00 07-FEB-12:30 1280.68 18-JUL-17:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.22 0.00 01-JAN-00:15 429.70 05-FEB-08:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 10.17 0.00 01-JAN-10:15 1280.68 18-JUL-17:30
EnergyTransfer:Zone:G S1 APARTMENT 13.38 0.03 07-NOV-07:00 1482.76 10-SEP-14:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.04 0.00 01-JAN-00:15 300.35 10-JAN-05:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 13.33 0.00 05-JAN-03:00 1482.76 10-SEP-14:15
EnergyTransfer:Zone:G S2 APARTMENT 13.06 0.02 14-DEC-07:45 1495.73 10-SEP-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.05 0.00 01-JAN-00:15 297.85 05-FEB-04:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 13.01 0.00 05-JAN-02:45 1495.73 10-SEP-13:30
EnergyTransfer:Zone:M SW APARTMENT 64.03 0.11 24-DEC-08:00 5931.37 11-OCT-15:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 117.22 08-JAN-12:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 64.02 0.00 08-JAN-09:15 5931.37 11-OCT-15:30
EnergyTransfer:Zone:M NW APARTMENT 51.83 0.06 05-NOV-06:45 5217.69 07-JUL-16:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 0.06 0.00 01-JAN-00:15 658.65 05-FEB-07:45
Cooling:EnergyTransfer:Zone:M NW APARTMENT 51.76 0.00 06-JAN-10:45 5217.69 07-JUL-16:30
EnergyTransfer:Zone:M SE APARTMENT 64.33 1.19 24-DEC-06:30 5355.73 09-OCT-11:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 135.29 05-FEB-07:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 64.33 0.00 08-JAN-09:30 5355.73 09-OCT-11:30
EnergyTransfer:Zone:M NE APARTMENT 52.18 0.04 15-FEB-12:45 4259.06 10-SEP-10:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 0.04 0.00 01-JAN-00:15 691.82 05-FEB-07:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 52.14 0.00 06-JAN-11:00 4259.06 10-SEP-10:00
EnergyTransfer:Zone:M N1 APARTMENT 44.92 3.00 11-JAN-12:15 3305.14 28-JUN-17:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 142.22 23-DEC-16:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 44.92 0.00 11-JAN-12:15 3305.14 28-JUN-17:30
EnergyTransfer:Zone:M N2 APARTMENT 44.93 1.82 11-JAN-12:15 3297.31 28-JUN-17:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 142.84 23-DEC-16:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 44.92 0.00 11-JAN-12:15 3297.31 28-JUN-17:30
EnergyTransfer:Zone:M S1 APARTMENT 57.55 140.47 08-JAN-09:30 4698.49 01-JAN-13:45
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 57.55 140.47 08-JAN-09:30 4698.49 01-JAN-13:45
EnergyTransfer:Zone:M S2 APARTMENT 57.56 139.87 08-JAN-09:30 4703.82 01-JAN-13:45
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 57.56 139.87 08-JAN-09:30 4703.82 01-JAN-13:45
EnergyTransfer:Zone:T SW APARTMENT 31.99 0.00 09-NOV-03:30 3604.88 11-OCT-15:30
Heating:EnergyTransfer:Zone:T SW APARTMENT 0.56 0.00 01-JAN-00:15 1466.39 05-FEB-07:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 31.43 0.00 01-JAN-05:00 3604.88 11-OCT-15:30
EnergyTransfer:Zone:T NW APARTMENT 27.19 0.02 25-NOV-09:30 3349.26 07-JUL-16:30
Heating:EnergyTransfer:Zone:T NW APARTMENT 1.03 0.00 01-JAN-00:15 1511.10 05-FEB-09:15
Cooling:EnergyTransfer:Zone:T NW APARTMENT 26.17 0.00 01-JAN-03:15 3349.26 07-JUL-16:30
EnergyTransfer:Zone:T SE APARTMENT 32.00 0.07 01-MAR-05:15 3272.17 09-OCT-13:30
Heating:EnergyTransfer:Zone:T SE APARTMENT 0.50 0.00 01-JAN-00:15 1440.75 05-FEB-05:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 31.50 0.00 01-JAN-05:00 3272.17 09-OCT-13:30
EnergyTransfer:Zone:T NE APARTMENT 27.09 0.04 08-APR-02:00 2682.31 22-JUL-16:30
Heating:EnergyTransfer:Zone:T NE APARTMENT 0.87 0.00 01-JAN-00:15 1468.13 05-FEB-02:45
Cooling:EnergyTransfer:Zone:T NE APARTMENT 26.21 0.00 01-JAN-02:30 2682.31 22-JUL-16:30
EnergyTransfer:Zone:T N1 APARTMENT 22.87 0.01 15-FEB-15:00 2215.08 22-JUL-16:30
Heating:EnergyTransfer:Zone:T N1 APARTMENT 0.33 0.00 01-JAN-00:15 925.30 05-FEB-09:15
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 22.54 0.00 01-JAN-09:00 2215.08 22-JUL-16:30
EnergyTransfer:Zone:T N2 APARTMENT 22.87 0.01 31-DEC-12:30 2208.33 22-JUL-16:30
Heating:EnergyTransfer:Zone:T N2 APARTMENT 0.33 0.00 01-JAN-00:15 923.94 05-FEB-09:15
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 22.54 0.00 01-JAN-09:00 2208.33 22-JUL-16:30
EnergyTransfer:Zone:T S1 APARTMENT 28.07 0.13 18-JAN-07:15 2817.52 09-OCT-13:30
Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.11 0.00 01-JAN-00:15 874.27 05-FEB-06:45
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 27.96 0.00 04-JAN-03:45 2817.52 09-OCT-13:30
EnergyTransfer:Zone:T S2 APARTMENT 28.08 0.00 17-APR-09:00 2821.69 09-OCT-13:30
Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.12 0.00 01-JAN-00:15 875.85 05-FEB-06:45
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 27.97 0.00 01-JAN-06:45 2821.69 09-OCT-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 1346.82 0.00 03-JAN-01:30 116106.77 10-SEP-15:15
HeatingCoils:EnergyTransfer 10.73 0.00 01-JAN-00:15 30506.60 05-FEB-07:15
CoolingCoils:EnergyTransfer 1336.09 0.00 03-JAN-01:30 116106.77 10-SEP-15:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 0.291 -16.344 0.000 0.000 3.624 2.413 12.213 15.250 0.000 0.410 0.000 0.000 -3.551 0.000 -1.600 -12.705
G NW APARTMENT 0.711 -12.934 0.000 0.000 3.653 2.413 12.213 9.611 0.000 0.408 0.000 0.000 -3.604 0.000 -1.473 -10.998
OFFICE 0.254 -31.647 0.000 0.000 0.517 21.914 7.534 15.546 0.000 0.367 0.000 0.000 -3.376 0.000 -0.777 -10.333
G NE APARTMENT 0.570 -13.074 0.000 0.000 3.662 2.413 12.213 9.594 0.000 0.408 0.000 0.000 -3.460 0.000 -1.464 -10.862
G N1 APARTMENT 0.221 -10.168 0.000 0.000 3.665 2.413 12.213 4.190 0.000 0.283 0.000 0.000 -2.192 0.000 -1.112 -9.513
G N2 APARTMENT 0.219 -10.174 0.000 0.000 3.666 2.413 12.213 4.189 0.000 0.283 0.000 0.000 -2.191 0.000 -1.111 -9.507
G S1 APARTMENT 0.042 -13.333 0.000 0.000 3.622 2.413 12.213 9.861 0.000 0.283 0.000 0.000 -2.132 0.000 -1.276 -11.693
G S2 APARTMENT 0.054 -13.011 0.000 0.000 3.623 2.413 12.213 9.866 0.000 0.283 0.000 0.000 -2.125 0.000 -1.275 -12.041
M SW APARTMENT 0.003 -64.023 0.000 0.000 3.538 2.413 12.213 14.668 0.000 0.569 37.021 0.000 -4.178 0.000 -2.224 0.000
M NW APARTMENT 0.062 -51.764 0.000 0.000 3.560 2.413 12.213 9.104 0.000 0.566 30.345 0.000 -4.307 0.000 -2.191 0.000
M SE APARTMENT 0.001 -64.327 0.000 0.000 3.540 2.413 12.213 14.703 0.000 0.569 37.221 0.000 -4.110 0.000 -2.223 0.000
M NE APARTMENT 0.043 -52.138 0.000 0.000 3.564 2.413 12.213 9.057 0.000 0.566 30.616 0.000 -4.148 0.000 -2.186 0.000
M N1 APARTMENT 0.003 -44.917 0.000 0.000 3.549 2.413 12.213 3.886 0.000 0.386 26.900 0.000 -2.716 0.000 -1.717 0.000
M N2 APARTMENT 0.003 -44.923 0.000 0.000 3.549 2.413 12.213 3.886 0.000 0.386 26.905 0.000 -2.715 0.000 -1.717 0.000
M S1 APARTMENT 0.000 -57.550 0.000 0.000 3.528 2.413 12.213 9.487 0.000 0.388 33.783 0.000 -2.523 0.000 -1.739 0.000
M S2 APARTMENT 0.000 -57.558 0.000 0.000 3.528 2.413 12.213 9.487 0.000 0.388 33.790 0.000 -2.522 0.000 -1.739 0.000
T SW APARTMENT 0.558 -31.427 0.000 0.000 3.581 2.413 12.213 14.377 0.000 0.741 4.177 0.000 -3.952 0.000 -2.680 -0.000
T NW APARTMENT 1.026 -26.166 0.000 0.000 3.602 2.413 12.213 8.892 0.000 0.737 3.941 0.000 -4.051 0.000 -2.606 -0.000
T SE APARTMENT 0.498 -31.503 0.000 0.000 3.585 2.413 12.213 14.411 0.000 0.741 4.208 0.000 -3.885 0.000 -2.680 -0.000
T NE APARTMENT 0.873 -26.214 0.000 0.000 3.609 2.413 12.213 8.867 0.000 0.737 4.016 0.000 -3.909 0.000 -2.605 -0.000
T N1 APARTMENT 0.328 -22.541 0.000 0.000 3.600 2.413 12.213 3.810 0.000 0.501 4.178 0.000 -2.515 0.000 -1.987 -0.000
T N2 APARTMENT 0.330 -22.544 0.000 0.000 3.600 2.413 12.213 3.809 0.000 0.501 4.178 0.000 -2.513 0.000 -1.987 -0.000
T S1 APARTMENT 0.114 -27.955 0.000 0.000 3.571 2.413 12.213 9.319 0.000 0.505 4.288 0.000 -2.400 0.000 -2.068 -0.000
T S2 APARTMENT 0.116 -27.965 0.000 0.000 3.571 2.413 12.213 9.318 0.000 0.505 4.296 0.000 -2.399 0.000 -2.068 -0.000
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.219 0.000 0.035 0.000 0.000 -0.467 0.000 -0.356 -16.501
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.806 0.000 2.445 0.000 0.000 -0.971 0.000 -9.190 -16.424
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.231 0.000 0.032 0.000 0.000 -0.517 0.000 -0.296 -16.519
Total Facility 6.319 -774.199 0.000 0.000 83.107 128.627 294.692 226.441 0.000 14.020 289.864 0.000 -77.428 0.000 -54.348 -137.096


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 30-AUG-16:15 0.00 -2386.18 0.00 0.00 84.76 144.04 588.62 2132.08 0.00 50.93 0.00 0.00 0.00 0.00 0.00 -614.26
G NW APARTMENT 07-JUL-16:30 0.00 -2170.37 0.00 0.00 84.76 144.04 588.62 1964.71 0.00 59.78 0.00 0.00 0.00 0.00 0.00 -671.53
OFFICE 10-SEP-10:45 0.00 -3820.07 0.00 0.00 67.31 1622.34 544.92 2223.82 0.00 62.06 0.00 0.00 0.00 0.00 0.00 -700.37
G NE APARTMENT 10-SEP-09:45 0.00 -1729.44 0.00 0.00 40.75 28.81 406.15 1750.64 0.00 73.41 0.00 0.00 0.00 0.00 0.00 -570.33
G N1 APARTMENT 18-JUL-17:30 0.00 -1285.73 0.00 0.00 141.81 194.45 588.62 542.09 0.00 30.64 0.00 0.00 0.00 0.00 0.00 -211.89
G N2 APARTMENT 18-JUL-17:30 0.00 -1280.79 0.00 0.00 141.81 194.45 588.62 542.17 0.00 30.64 0.00 0.00 0.00 0.00 0.00 -216.90
G S1 APARTMENT 10-SEP-14:15 0.00 -1482.63 0.00 0.00 40.66 50.41 400.26 1161.48 0.00 32.37 0.00 0.00 0.00 0.00 0.00 -202.55
G S2 APARTMENT 10-SEP-13:30 0.00 -1495.63 0.00 0.00 40.71 28.81 382.60 1301.20 0.00 36.64 0.00 0.00 0.00 0.00 0.00 -294.34
M SW APARTMENT 11-OCT-15:30 0.00 -5931.51 0.00 0.00 48.90 100.83 470.90 2435.71 0.00 99.78 2775.39 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 07-JUL-16:30 0.00 -5217.70 0.00 0.00 84.76 144.04 588.62 1937.27 0.00 85.72 2377.30 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 09-OCT-11:30 0.00 -5355.54 0.00 0.00 40.75 28.81 406.15 2248.31 0.00 182.18 2449.34 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 10-SEP-10:00 0.00 -4259.12 0.00 0.00 40.75 28.81 406.15 1680.31 0.00 111.72 1991.37 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 28-JUN-17:23 0.00 -3305.28 0.00 0.00 141.81 194.45 588.62 593.12 0.00 64.00 1723.28 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 28-JUN-17:23 0.00 -3297.47 0.00 0.00 141.81 194.45 588.62 593.16 0.00 64.00 1715.42 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 01-JAN-13:45 0.00 -4697.86 0.00 0.00 40.75 28.81 388.49 2133.02 0.00 27.11 2079.68 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 01-JAN-13:45 0.00 -4703.19 0.00 0.00 40.75 28.81 388.49 2132.98 0.00 27.11 2085.05 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 11-OCT-15:30 0.00 -3605.02 0.00 0.00 48.90 100.83 470.90 2380.11 0.00 131.12 473.16 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 07-JUL-16:30 0.00 -3349.30 0.00 0.00 84.76 144.04 588.62 1889.95 0.00 112.89 529.04 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 09-OCT-13:30 0.00 -3272.39 0.00 0.00 40.76 28.81 382.60 1957.55 0.00 263.71 598.97 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 22-JUL-16:23 0.00 -2682.41 0.00 0.00 84.76 144.04 588.62 1002.39 0.00 54.96 807.63 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 22-JUL-16:23 0.00 -2215.47 0.00 0.00 84.76 144.04 588.62 629.43 0.00 33.15 735.47 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 22-JUL-16:23 0.00 -2208.72 0.00 0.00 84.76 144.04 588.62 629.52 0.00 33.15 728.63 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 09-OCT-13:30 0.00 -2817.58 0.00 0.00 40.75 28.81 382.60 1701.64 0.00 159.05 504.72 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 09-OCT-13:30 0.00 -2821.75 0.00 0.00 40.75 28.81 382.60 1701.56 0.00 159.05 508.97 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 10-SEP-15:15 0.00 -66996.10 0.00 0.00 1192.00 5565.24 11658.39 27035.11 0.00 1881.04 19664.32 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 26-JAN-07:01 1188.28 0.00 0.00 0.00 162.90 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -572.40 0.00 -96.16 -1158.85
G NW APARTMENT 05-FEB-08:17 883.19 0.00 0.00 0.00 74.14 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -744.69 0.00 -290.64 -353.70
OFFICE 22-JAN-07:01 2520.77 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -541.83 0.00 -112.03 -2441.48
G NE APARTMENT 05-FEB-07:00 809.28 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -1023.38 0.00 -279.10 -115.16
G N1 APARTMENT 24-JAN-08:01 1031.11 0.00 0.00 0.00 74.04 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -275.72 0.00 -47.56 -1213.56
G N2 APARTMENT 24-JAN-08:01 957.99 0.00 0.00 0.00 74.86 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -272.73 0.00 -47.57 -1144.25
G S1 APARTMENT 10-JAN-05:15 600.70 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -484.13 0.00 -74.41 -578.56
G S2 APARTMENT 10-JAN-06:00 541.89 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -450.88 0.00 -68.61 -558.80
M SW APARTMENT 10-MAR-12:23 135.04 0.00 0.00 0.00 41.78 28.81 406.15 199.98 0.00 0.00 0.00 0.00 0.00 0.00 -515.98 -295.77
M NW APARTMENT 05-FEB-07:45 658.65 0.00 0.00 0.00 161.22 93.63 382.60 0.00 0.00 0.00 134.22 0.00 -995.59 0.00 -434.73 0.00
M SE APARTMENT 05-FEB-07:05 137.15 0.00 0.00 0.00 161.22 93.63 382.60 0.00 0.00 0.00 682.69 0.00 -1044.41 0.00 -412.88 0.00
M NE APARTMENT 05-FEB-07:00 692.07 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 167.56 0.00 -1066.03 0.00 -401.96 0.00
M N1 APARTMENT 23-DEC-16:00 142.23 0.00 0.00 0.00 40.77 50.41 400.26 42.68 0.00 0.00 0.00 0.00 0.00 0.00 -156.66 -519.69
M N2 APARTMENT 23-DEC-16:00 142.85 0.00 0.00 0.00 40.84 50.41 400.26 43.21 0.00 0.00 0.00 0.00 0.00 0.00 -154.86 -522.70
M S1 APARTMENT - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 05-FEB-06:53 1470.05 0.00 0.00 0.00 190.63 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -1005.94 0.00 -529.32 -544.10
T NW APARTMENT 05-FEB-09:15 1521.97 0.00 0.00 0.00 47.84 28.81 394.38 0.00 0.00 0.00 0.00 0.00 -594.35 0.00 -520.40 -878.26
T SE APARTMENT 05-FEB-05:00 1440.72 0.00 0.00 0.00 189.67 43.21 223.68 0.00 0.00 0.00 0.00 0.00 -956.22 0.00 -414.75 -526.31
T NE APARTMENT 05-FEB-02:45 1468.09 0.00 0.00 0.00 189.67 14.40 229.56 0.00 0.00 0.00 0.00 0.00 -929.36 0.00 -436.87 -535.50
T N1 APARTMENT 05-FEB-09:15 930.20 0.00 0.00 0.00 47.84 28.81 394.38 0.00 0.00 0.00 0.00 0.00 -376.84 0.00 -313.55 -710.84
T N2 APARTMENT 05-FEB-09:15 929.08 0.00 0.00 0.00 47.81 28.81 394.38 0.00 0.00 0.00 0.00 0.00 -377.28 0.00 -313.83 -708.97
T S1 APARTMENT 05-FEB-06:45 874.30 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -627.62 0.00 -301.69 -553.34
T S2 APARTMENT 23-DEC-07:01 1174.31 0.00 0.00 0.00 162.51 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -357.04 0.00 -194.78 -1261.24
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 05-FEB-07:01 12170.80 0.00 0.00 0.00 3722.06 4156.84 9398.91 0.00 0.00 0.00 13365.55 0.00 -20095.58 0.00 -22718.58 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Sec1.1A-General Information

Data
Weather File Tampa-MacDill AFB FL USA TMY3 WMO#=747880
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 18.50
Number of hours cooling loads not met 1.00
Number of hours not met 19.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 8572.78 0.00 0.00 0.00 0.00
Exterior Lighting 39.40 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 13.41 38133.26 0.00 0.00
Space Cooling 323.87 29077.82 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 214.43 6799.41 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 320.37 18649.28 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 26456.41 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1574.49   13.41   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1574.49
Natural Gas 0.00 13.41
Additional 0.00 0.00
Total 511.42 1587.90


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 103.32
Fans-Interior 68.41
Service Water Heating 102.20
Receptacle Equipment 163.15
Miscellaneous 12.57
Subtotal 502.29


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 4.28
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 4.28


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 10.39
Space Heating 0.84
Space Cooling 20.40
Fans-Interior 13.50
Service Water Heating 20.18
Receptacle Equipment 32.21
Miscellaneous 2.48



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.193169
G NW APARTMENT DIRECT AIR 0.182981
OFFICE DIRECT AIR 0.457831
G NE APARTMENT DIRECT AIR 0.152281
G N1 APARTMENT DIRECT AIR 0.103002
G N2 APARTMENT DIRECT AIR 0.102334
G S1 APARTMENT DIRECT AIR 0.118357
G S2 APARTMENT DIRECT AIR 0.121114
M SW APARTMENT DIRECT AIR 0.464513
M NW APARTMENT DIRECT AIR 0.440102
M SE APARTMENT DIRECT AIR 0.415008
M NE APARTMENT DIRECT AIR 0.374912
M N1 APARTMENT DIRECT AIR 0.260124
M N2 APARTMENT DIRECT AIR 0.259051
M S1 APARTMENT DIRECT AIR 0.296749
M S2 APARTMENT DIRECT AIR 0.297669
T SW APARTMENT DIRECT AIR 0.296020
T NW APARTMENT DIRECT AIR 0.279341
T SE APARTMENT DIRECT AIR 0.259383
T NE APARTMENT DIRECT AIR 0.229251
T N1 APARTMENT DIRECT AIR 0.172911
T N2 APARTMENT DIRECT AIR 0.172872
T S1 APARTMENT DIRECT AIR 0.210349
T S2 APARTMENT DIRECT AIR 0.210989


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.193169
SPLIT GNW MAIN BRANCH 0.182981
SPLIT OFFICE MAIN BRANCH 0.457831
SPLIT GNE MAIN BRANCH 0.152281
SPLIT GN1 MAIN BRANCH 0.103002
SPLIT GN2 MAIN BRANCH 0.102334
SPLIT GS1 MAIN BRANCH 0.118357
SPLIT GS2 MAIN BRANCH 0.121114
SPLIT MSW MAIN BRANCH 0.464513
SPLIT MNW MAIN BRANCH 0.440102
SPLIT MSE MAIN BRANCH 0.415008
SPLIT MNE MAIN BRANCH 0.374912
SPLIT MN1 MAIN BRANCH 0.260124
SPLIT MN2 MAIN BRANCH 0.259051
SPLIT MS1 MAIN BRANCH 0.296749
SPLIT MS2 MAIN BRANCH 0.297669
SPLIT TSW MAIN BRANCH 0.296020
SPLIT TNW MAIN BRANCH 0.279341
SPLIT TSE MAIN BRANCH 0.259383
SPLIT TNE MAIN BRANCH 0.229251
SPLIT TN1 MAIN BRANCH 0.172911
SPLIT TN2 MAIN BRANCH 0.172872
SPLIT TS1 MAIN BRANCH 0.210349
SPLIT TS2 MAIN BRANCH 0.210989


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.193169
SPLIT GNW 0.182981
SPLIT OFFICE 0.457831
SPLIT GNE 0.152281
SPLIT GN1 0.103002
SPLIT GN2 0.102334
SPLIT GS1 0.118357
SPLIT GS2 0.121114
SPLIT MSW 0.464513
SPLIT MNW 0.440102
SPLIT MSE 0.415008
SPLIT MNE 0.374912
SPLIT MN1 0.260124
SPLIT MN2 0.259051
SPLIT MS1 0.296749
SPLIT MS2 0.297669
SPLIT TSW 0.296020
SPLIT TNW 0.279341
SPLIT TSE 0.259383
SPLIT TNE 0.229251
SPLIT TN1 0.172911
SPLIT TN2 0.172872
SPLIT TS1 0.210349
SPLIT TS2 0.210989


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.193169 0.026898
SPLIT GNW OA CONTROLLER 0.182981 0.025953
SPLIT OFFICE OA CONTROLLER 0.457831 0.038104
SPLIT GNE OA CONTROLLER 0.152281 0.025953
SPLIT GN1 OA CONTROLLER 0.103002 0.025953
SPLIT GN2 OA CONTROLLER 0.102334 0.025953
SPLIT GS1 OA CONTROLLER 0.118357 0.025953
SPLIT GS2 OA CONTROLLER 0.121114 0.025953
SPLIT MSW OA CONTROLLER 0.464513 0.051906
SPLIT MNW OA CONTROLLER 0.440102 0.051906
SPLIT MSE OA CONTROLLER 0.415008 0.051906
SPLIT MNE OA CONTROLLER 0.374912 0.051906
SPLIT MN1 OA CONTROLLER 0.260124 0.051906
SPLIT MN2 OA CONTROLLER 0.259051 0.051906
SPLIT MS1 OA CONTROLLER 0.296749 0.051906
SPLIT MS2 OA CONTROLLER 0.297669 0.051906
SPLIT TSW OA CONTROLLER 0.296020 0.025953
SPLIT TNW OA CONTROLLER 0.279341 0.025953
SPLIT TSE OA CONTROLLER 0.259383 0.025953
SPLIT TNE OA CONTROLLER 0.229251 0.025953
SPLIT TN1 OA CONTROLLER 0.172911 0.025953
SPLIT TN2 OA CONTROLLER 0.172872 0.025953
SPLIT TS1 OA CONTROLLER 0.210349 0.025953
SPLIT TS2 OA CONTROLLER 0.210989 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.193169 4054.30 0.720970
SPLIT GNW COOLING COIL 0.182981 3846.04 0.720551
SPLIT OFFICE COOLING COIL 0.457831 8132.61 0.773616
SPLIT GNE COOLING COIL 0.152281 3282.18 0.713367
SPLIT GN1 COOLING COIL 0.103002 2460.78 0.685745
SPLIT GN2 COOLING COIL 0.102334 2449.65 0.685242
SPLIT GS1 COOLING COIL 0.118357 2802.34 0.688043
SPLIT GS2 COOLING COIL 0.121114 2843.95 0.690182
SPLIT MSW COOLING COIL 0.464513 9396.21 0.731869
SPLIT MNW COOLING COIL 0.440102 8965.32 0.729758
SPLIT MSE COOLING COIL 0.415008 8534.78 0.726935
SPLIT MNE COOLING COIL 0.374912 7805.83 0.723309
SPLIT MN1 COOLING COIL 0.260124 5858.42 0.701229
SPLIT MN2 COOLING COIL 0.259051 5840.76 0.700928
SPLIT MS1 COOLING COIL 0.296749 6651.35 0.702526
SPLIT MS2 COOLING COIL 0.297669 6666.40 0.702753
SPLIT TSW COOLING COIL 0.296020 5811.65 0.740994
SPLIT TNW COOLING COIL 0.279341 5509.95 0.739546
SPLIT TSE COOLING COIL 0.259383 5255.92 0.731349
SPLIT TNE COOLING COIL 0.229251 4669.01 0.729826
SPLIT TN1 COOLING COIL 0.172911 3750.35 0.711596
SPLIT TN2 COOLING COIL 0.172872 3756.55 0.711070
SPLIT TS1 COOLING COIL 0.210349 4377.40 0.723453
SPLIT TS2 COOLING COIL 0.210989 4388.37 0.723610


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.193169 0.193169 0.193169 0.193169 1476.43 4054.30 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.182981 0.182981 0.182981 0.182981 1424.54 3846.04 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.457831 0.457831 0.457831 0.457831 2771.00 8132.61 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.152281 0.152281 0.152281 0.152281 1424.54 3282.18 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.103002 0.103002 0.103002 0.103002 1424.54 2460.78 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.102334 0.102334 0.102334 0.102334 1424.54 2449.65 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.118357 0.118357 0.118357 0.118357 1424.54 2802.34 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.121114 0.121114 0.121114 0.121114 1424.54 2843.95 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.464513 0.464513 0.464513 0.464513 2849.07 9396.21 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.440102 0.440102 0.440102 0.440102 2849.07 8965.32 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.415008 0.415008 0.415008 0.415008 2849.07 8534.78 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.374912 0.374912 0.374912 0.374912 2849.07 7805.83 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.260124 0.260124 0.260124 0.260124 2849.07 5858.42 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.259051 0.259051 0.259051 0.259051 2849.07 5840.76 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.296749 0.296749 0.296749 0.296749 2849.07 6651.35 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.297669 0.297669 0.297669 0.297669 2849.07 6666.40 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.296020 0.296020 0.296020 0.296020 1902.87 5811.65 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.279341 0.279341 0.279341 0.279341 1917.66 5509.95 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.259383 0.259383 0.259383 0.259383 1902.87 5255.92 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.229251 0.229251 0.229251 0.229251 1917.66 4669.01 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.172911 0.172911 0.172911 0.172911 1433.51 3750.35 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.172872 0.172872 0.172872 0.172872 1433.51 3756.55 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.210349 0.210349 0.210349 0.210349 1424.54 4377.40 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.210989 0.210989 0.210989 0.210989 1424.54 4388.37 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.193169
SPLIT GNW SUPPLY FAN 0.182981
SPLIT OFFICE SUPPLY FAN 0.457831
SPLIT GNE SUPPLY FAN 0.152281
SPLIT GN1 SUPPLY FAN 0.103002
SPLIT GN2 SUPPLY FAN 0.102334
SPLIT GS1 SUPPLY FAN 0.118357
SPLIT GS2 SUPPLY FAN 0.121114
SPLIT MSW SUPPLY FAN 0.464513
SPLIT MNW SUPPLY FAN 0.440102
SPLIT MSE SUPPLY FAN 0.415008
SPLIT MNE SUPPLY FAN 0.374912
SPLIT MN1 SUPPLY FAN 0.260124
SPLIT MN2 SUPPLY FAN 0.259051
SPLIT MS1 SUPPLY FAN 0.296749
SPLIT MS2 SUPPLY FAN 0.297669
SPLIT TSW SUPPLY FAN 0.296020
SPLIT TNW SUPPLY FAN 0.279341
SPLIT TSE SUPPLY FAN 0.259383
SPLIT TNE SUPPLY FAN 0.229251
SPLIT TN1 SUPPLY FAN 0.172911
SPLIT TN2 SUPPLY FAN 0.172872
SPLIT TS1 SUPPLY FAN 0.210349
SPLIT TS2 SUPPLY FAN 0.210989


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 1476.43
SPLIT GNW HEATING COIL 1424.54
SPLIT OFFICE HEATING COIL 2771.00
SPLIT GNE HEATING COIL 1424.54
SPLIT GN1 HEATING COIL 1424.54
SPLIT GN2 HEATING COIL 1424.54
SPLIT GS1 HEATING COIL 1424.54
SPLIT GS2 HEATING COIL 1424.54
SPLIT MSW HEATING COIL 2849.07
SPLIT MNW HEATING COIL 2849.07
SPLIT MSE HEATING COIL 2849.07
SPLIT MNE HEATING COIL 2849.07
SPLIT MN1 HEATING COIL 2849.07
SPLIT MN2 HEATING COIL 2849.07
SPLIT MS1 HEATING COIL 2849.07
SPLIT MS2 HEATING COIL 2849.07
SPLIT TSW HEATING COIL 1902.87
SPLIT TNW HEATING COIL 1917.66
SPLIT TSE HEATING COIL 1902.87
SPLIT TNE HEATING COIL 1917.66
SPLIT TN1 HEATING COIL 1433.51
SPLIT TN2 HEATING COIL 1433.51
SPLIT TS1 HEATING COIL 1424.54
SPLIT TS2 HEATING COIL 1424.54



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:30

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.19 13.57
February 23.43 15.49
March 23.47 17.07
April 24.12 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 23.95 18.91
December 23.43 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 23.19 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 13.57
February 23.01 15.49
March 23.26 17.07
April 24.06 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.25 24.23
November 23.63 18.91
December 22.98 15.68
     
Annual Sum or Average 23.82 21.89
Minimum of Months 22.62 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.09 13.57
February 23.36 15.49
March 23.46 17.07
April 23.87 21.23
May 23.90 26.90
June 23.90 27.61
July 23.90 27.94
August 23.90 27.43
September 23.90 26.23
October 23.89 24.23
November 23.77 18.91
December 23.34 15.68
     
Annual Sum or Average 23.69 21.89
Minimum of Months 23.09 13.57
Maximum of Months 23.90 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.55 13.57
February 22.95 15.49
March 23.24 17.07
April 24.04 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.24 24.23
November 23.60 18.91
December 22.90 15.68
     
Annual Sum or Average 23.80 21.89
Minimum of Months 22.55 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.47 13.57
February 22.84 15.49
March 23.12 17.07
April 23.95 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.23 24.23
November 23.51 18.91
December 22.85 15.68
     
Annual Sum or Average 23.75 21.89
Minimum of Months 22.47 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.47 13.57
February 22.84 15.49
March 23.12 17.07
April 23.95 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.23 24.23
November 23.51 18.91
December 22.84 15.68
     
Annual Sum or Average 23.75 21.89
Minimum of Months 22.47 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.23 13.57
February 23.43 15.49
March 23.45 17.07
April 24.08 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 23.99 18.91
December 23.48 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 23.23 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.22 13.57
February 23.42 15.49
March 23.44 17.07
April 24.07 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 23.98 18.91
December 23.47 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 23.22 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.12 13.57
February 24.19 15.49
March 24.20 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.40 24.23
November 24.38 18.91
December 24.20 15.68
     
Annual Sum or Average 24.32 21.89
Minimum of Months 24.12 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.62 13.57
February 23.94 15.49
March 24.09 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.39 24.23
November 24.33 18.91
December 23.92 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.62 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.11 13.57
February 24.19 15.49
March 24.20 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.40 24.23
November 24.38 18.91
December 24.18 15.68
     
Annual Sum or Average 24.32 21.89
Minimum of Months 24.11 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.57 13.57
February 23.91 15.49
March 24.08 17.07
April 24.39 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.39 24.23
November 24.33 18.91
December 23.87 15.68
     
Annual Sum or Average 24.21 21.89
Minimum of Months 23.57 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.77 13.57
February 24.01 15.49
March 24.19 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.39 24.23
November 24.37 18.91
December 24.05 15.68
     
Annual Sum or Average 24.27 21.89
Minimum of Months 23.77 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.77 13.57
February 24.01 15.49
March 24.19 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.39 24.23
November 24.37 18.91
December 24.05 15.68
     
Annual Sum or Average 24.26 21.89
Minimum of Months 23.77 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.26 13.57
February 24.29 15.49
March 24.29 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.40 24.23
November 24.40 18.91
December 24.30 15.68
     
Annual Sum or Average 24.36 21.89
Minimum of Months 24.26 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.26 13.57
February 24.29 15.49
March 24.29 17.07
April 24.40 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.40 24.23
November 24.40 18.91
December 24.30 15.68
     
Annual Sum or Average 24.36 21.89
Minimum of Months 24.26 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.55 13.57
February 23.84 15.49
March 23.86 17.07
April 24.33 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.36 24.23
November 24.18 18.91
December 23.73 15.68
     
Annual Sum or Average 24.15 21.89
Minimum of Months 23.55 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.11 13.57
February 23.58 15.49
March 23.73 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.32 24.23
November 24.01 18.91
December 23.40 15.68
     
Annual Sum or Average 24.04 21.89
Minimum of Months 23.11 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.54 13.57
February 23.83 15.49
March 23.86 17.07
April 24.33 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.35 24.23
November 24.17 18.91
December 23.70 15.68
     
Annual Sum or Average 24.15 21.89
Minimum of Months 23.54 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.04 13.57
February 23.54 15.49
March 23.72 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 24.02 18.91
December 23.34 15.68
     
Annual Sum or Average 24.02 21.89
Minimum of Months 23.04 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.06 13.57
February 23.56 15.49
March 23.74 17.07
April 24.33 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.33 24.23
November 24.05 18.91
December 23.41 15.68
     
Annual Sum or Average 24.04 21.89
Minimum of Months 23.06 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.05 13.57
February 23.56 15.49
March 23.74 17.07
April 24.33 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.33 24.23
November 24.05 18.91
December 23.40 15.68
     
Annual Sum or Average 24.04 21.89
Minimum of Months 23.05 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.67 13.57
February 23.92 15.49
March 23.94 17.07
April 24.35 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.37 24.23
November 24.25 18.91
December 23.84 15.68
     
Annual Sum or Average 24.20 21.89
Minimum of Months 23.67 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.67 13.57
February 23.92 15.49
March 23.93 17.07
April 24.35 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.37 24.23
November 24.25 18.91
December 23.84 15.68
     
Annual Sum or Average 24.20 21.89
Minimum of Months 23.67 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.57 13.57
February 25.14 15.49
March 25.41 17.07
April 26.45 21.23
May 27.18 26.90
June 27.29 27.61
July 27.32 27.94
August 27.26 27.43
September 27.10 26.23
October 26.85 24.23
November 25.91 18.91
December 25.03 15.68
     
Annual Sum or Average 26.30 21.89
Minimum of Months 24.57 13.57
Maximum of Months 27.32 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.31 13.57
February 22.88 15.49
March 23.28 17.07
April 24.55 21.23
May 25.89 26.90
June 26.88 27.61
July 27.03 27.94
August 26.97 27.43
September 26.71 26.23
October 25.52 24.23
November 23.99 18.91
December 22.95 15.68
     
Annual Sum or Average 24.92 21.89
Minimum of Months 22.31 13.57
Maximum of Months 27.03 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 25.99 13.57
February 26.25 15.49
March 26.37 17.07
April 26.80 21.23
May 27.04 26.90
June 27.09 27.61
July 27.10 27.94
August 27.08 27.43
September 27.02 26.23
October 26.97 24.23
November 26.68 18.91
December 26.26 15.68
     
Annual Sum or Average 26.72 21.89
Minimum of Months 25.99 13.57
Maximum of Months 27.10 27.94



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:30

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.117778E+12 76315.099 01-JAN-18:30 8572.775 26456.413 6799.406 0.000 8641.725 2508.330 0.000 0.000 0.000 0.000 0.000 23336.451 0.000 0.000 0.000
February 0.108767E+12 75466.387 02-FEB-18:00 8572.775 26456.413 6799.406 0.000 10313.801 2508.330 0.000 0.000 0.000 0.000 0.000 20815.663 0.000 0.000 0.000
March 0.120829E+12 77687.966 07-MAR-18:30 8572.775 26456.413 6799.406 0.000 12278.207 2508.330 0.000 0.000 0.000 0.000 0.000 21072.836 0.000 0.000 0.000
April 0.123831E+12 80263.273 28-APR-16:30 7009.952 26456.413 6799.406 0.000 22911.974 0.000 0.000 0.000 0.000 0.000 0.000 17085.529 0.000 0.000 0.000
May 0.143439E+12 82316.519 28-MAY-16:15 7009.952 26456.413 6799.406 0.000 24019.859 0.000 0.000 0.000 0.000 0.000 0.000 18030.890 0.000 0.000 0.000
June 0.141563E+12 83951.166 15-JUN-17:30 8572.775 26456.413 6799.406 0.000 23144.086 0.000 0.000 0.000 0.000 0.000 0.000 18978.487 0.000 0.000 0.000
July 0.148751E+12 85375.577 23-JUL-17:15 8572.775 26456.413 6799.406 0.000 24993.223 0.000 0.000 0.000 0.000 0.000 0.000 18553.761 0.000 0.000 0.000
August 0.147781E+12 87205.749 24-AUG-17:00 8572.775 26456.413 6799.406 0.000 25280.730 0.000 0.000 0.000 0.000 0.000 0.000 20096.426 0.000 0.000 0.000
September 0.140792E+12 89555.694 09-SEP-17:15 8572.775 26456.413 6799.406 0.000 29077.819 0.000 0.000 0.000 0.000 0.000 0.000 18649.282 0.000 0.000 0.000
October 0.139282E+12 86818.526 07-OCT-16:30 7009.952 26456.413 6799.406 0.000 24998.230 0.000 0.000 0.000 0.000 0.000 0.000 21554.527 0.000 0.000 0.000
November 0.121012E+12 77537.922 03-NOV-17:15 8572.775 26456.413 6799.406 0.000 17474.020 0.000 0.000 0.000 0.000 0.000 0.000 18235.309 0.000 0.000 0.000
December 0.120669E+12 76367.114 15-DEC-18:15 8572.775 26456.413 6799.406 0.000 13621.454 2508.330 0.000 0.000 0.000 0.000 0.000 18408.737 0.000 0.000 0.000
                                     
Annual Sum or Average 0.157449E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.108767E+12 75466.387   7009.952 26456.413 6799.406 0.000 8641.725 0.000 0.000 0.000 0.000 0.000 0.000 17085.529 0.000 0.000 0.000
Maximum of Months 0.148751E+12 89555.694   8572.775 26456.413 6799.406 0.000 29077.819 2508.330 0.000 0.000 0.000 0.000 0.000 23336.451 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:30

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.486896E+10 21472.173 05-JAN-04:00 21472.173 0.000 0.000 0.000 0.000 0.000 21472.173
February 0.336922E+10 38133.256 05-FEB-07:15 38133.256 0.000 0.000 0.000 0.000 0.000 38133.256
March 0.195892E+10 15189.862 09-MAR-06:45 15189.862 0.000 0.000 0.000 0.000 0.000 15189.862
April 0.000 0.000 01-APR-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.000 0.000 01-MAY-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.000 0.000 01-JUN-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.000 0.000 01-SEP-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.000 0.000 01-OCT-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.108988E+09 3409.584 16-NOV-04:00 3409.584 0.000 0.000 0.000 0.000 0.000 3409.584
December 0.310392E+10 27281.061 20-DEC-07:30 27281.061 0.000 0.000 0.000 0.000 0.000 27281.061
                     
Annual Sum or Average 0.134100E+11       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.486896E+10 38133.256   38133.256 0.000 0.000 0.000 0.000 0.000 38133.256