Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Honolulu Intl Arpt HI USA TMY3 WMO#=911820
Simulation Timestamp: 2018-10-19 09:20:28
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1636.84 | 522.18 | 579.62 |
Net Site Energy | 1636.84 | 522.18 | 579.62 |
Total Source Energy | 5183.87 | 1653.75 | 1835.66 |
Net Source Energy | 5183.87 | 1653.75 | 1835.66 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 404.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 220.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 295.89 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1636.84 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 404.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 220.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 295.89 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 326.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 579.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 293.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 522.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1636.84 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1636.84 | 100.00 |
Total On-Site and Utility Electric Sources | 1636.84 | 100.00 |
Total Electricity End Uses | 1636.84 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 112.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2852.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Weather File | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Latitude [deg] | 21.32 |
Longitude [deg] | -157.9 |
Elevation [m] | 2.00 |
Time Zone | -10.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 05-SEP-17:45 | - | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 24976.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6983.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 22083.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 89071.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 24976.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6983.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 22083.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1282.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 125.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 697.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 937.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 5183.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 454.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 246.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 331.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1835.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 454.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 246.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 331.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1835.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.00 | 16.20 | Wetbulb [C] | 1.90 | 320.00 |
HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 32.20 | 7.10 | 23.30 | Wetbulb [C] | 6.70 | 60.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.55 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 5.778 | 0.306 | 0.155 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 5.778 | 0.306 | 0.155 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_1.22_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 5.778 | 0.306 | 0.155 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_1.22_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 5.778 | 0.306 | 0.155 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_1.22_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 5.778 | 0.306 | 0.155 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 5.778 | 0.306 | 0.155 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 5.778 | 0.306 | 0.155 | ||||||||||||
North Total or Average | 112.97 | 5.778 | 0.306 | 0.155 | ||||||||||||
Non-North Total or Average | 193.95 | 5.778 | 0.306 | 0.155 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.86 | 83.86 | 39.48 | |
Exterior Lighting Total | 2508.33 | 39.48 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4117.17 | 3051.06 | 1066.11 | 0.74 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4056.69 | 3011.64 | 1045.05 | 0.74 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7717.34 | 6049.38 | 1667.96 | 0.78 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3177.03 | 2304.68 | 872.34 | 0.73 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2427.09 | 1719.93 | 707.17 | 0.71 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2408.06 | 1704.67 | 703.39 | 0.71 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2417.48 | 1708.35 | 709.13 | 0.71 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2410.01 | 1708.18 | 701.83 | 0.71 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9769.43 | 7308.69 | 2460.74 | 0.75 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9646.28 | 7213.20 | 2433.08 | 0.75 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8071.79 | 5927.27 | 2144.52 | 0.73 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7717.59 | 5663.41 | 2054.18 | 0.73 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5889.20 | 4246.72 | 1642.48 | 0.72 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5857.57 | 4221.27 | 1636.31 | 0.72 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5919.19 | 4261.79 | 1657.40 | 0.72 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5889.71 | 4238.14 | 1651.56 | 0.72 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5923.40 | 4461.56 | 1461.84 | 0.75 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5793.45 | 4363.06 | 1430.38 | 0.75 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5000.01 | 3688.78 | 1311.22 | 0.74 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4665.57 | 3445.11 | 1220.46 | 0.74 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3621.04 | 2649.53 | 971.50 | 0.73 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3588.01 | 2622.90 | 965.11 | 0.73 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3994.70 | 2922.43 | 1072.27 | 0.73 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4002.57 | 2928.88 | 1073.70 | 0.73 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3952.4 | 3.23 | 11.02 | 11.47 | 10.88 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3893.6 | 3.23 | 11.01 | 11.46 | 10.87 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7366.5 | 3.15 | 10.76 | 11.18 | 10.50 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3056.2 | 3.26 | 11.11 | 11.57 | 11.03 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2339.9 | 3.29 | 11.22 | 11.69 | 11.19 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2321.8 | 3.29 | 11.23 | 11.69 | 11.19 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2331.3 | 3.29 | 11.23 | 11.70 | 11.21 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2323.4 | 3.29 | 11.22 | 11.69 | 11.19 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9369.7 | 3.22 | 10.97 | 11.42 | 10.82 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9252.0 | 3.22 | 10.98 | 11.42 | 10.82 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7755.6 | 3.24 | 11.06 | 11.51 | 10.94 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7415.8 | 3.24 | 11.06 | 11.51 | 10.95 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5668.4 | 3.27 | 11.14 | 11.60 | 11.07 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5638.3 | 3.27 | 11.14 | 11.60 | 11.07 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5698.1 | 3.27 | 11.15 | 11.61 | 11.08 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5670.0 | 3.27 | 11.15 | 11.61 | 11.08 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5677.2 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5552.7 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4802.0 | 3.23 | 11.04 | 11.49 | 10.91 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4480.4 | 3.23 | 11.03 | 11.48 | 10.91 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3480.4 | 3.25 | 11.08 | 11.53 | 10.97 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3449.0 | 3.25 | 11.08 | 11.53 | 10.98 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3839.6 | 3.25 | 11.08 | 11.53 | 10.97 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3847.1 | 3.25 | 11.08 | 11.53 | 10.97 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1099.98 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 1558.20 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2122.63 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 1061.31 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 234.95 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 232.49 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 501.20 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 172.15 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 124.02 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 122.72 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 122.65 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 123.21 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.51 | 570.19 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.50 | 562.38 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 450.61 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 430.14 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 314.44 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 312.26 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 314.83 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 312.82 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 351.27 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 343.45 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 282.29 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 263.97 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.18 | 200.40 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.18 | 198.12 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 220.99 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 221.55 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2231.72 | 2678.07 | 0.175 | 0.210 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 17:45:00 | 30.67 | 0.01435 |
G NW APARTMENT | 2208.37 | 2650.04 | 0.173 | 0.208 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
OFFICE | 4531.68 | 5438.02 | 0.373 | 0.447 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:30:00 | 28.90 | 0.01435 |
G NE APARTMENT | 1635.15 | 1962.18 | 0.128 | 0.154 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 10:45:00 | 30.30 | 0.01435 |
G N1 APARTMENT | 1178.07 | 1413.68 | 0.092 | 0.111 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 29.96 | 0.01435 |
G N2 APARTMENT | 1165.74 | 1398.89 | 0.091 | 0.110 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 29.96 | 0.01435 |
G S1 APARTMENT | 1165.07 | 1398.09 | 0.091 | 0.109 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
G S2 APARTMENT | 1170.40 | 1404.48 | 0.092 | 0.110 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 29.96 | 0.01435 |
M SW APARTMENT | 5416.02 | 6499.23 | 0.424 | 0.509 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 17:45:00 | 30.67 | 0.01435 |
M NW APARTMENT | 5341.87 | 6410.25 | 0.418 | 0.502 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
M SE APARTMENT | 4279.87 | 5135.84 | 0.335 | 0.402 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 11:30:00 | 30.92 | 0.01435 |
M NE APARTMENT | 4085.46 | 4902.55 | 0.320 | 0.384 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 10:45:00 | 30.30 | 0.01435 |
M N1 APARTMENT | 2986.82 | 3584.19 | 0.234 | 0.281 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 29.96 | 0.01435 |
M N2 APARTMENT | 2966.16 | 3559.39 | 0.232 | 0.279 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 29.96 | 0.01435 |
M S1 APARTMENT | 2990.60 | 3588.71 | 0.234 | 0.281 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
M S2 APARTMENT | 2971.47 | 3565.76 | 0.233 | 0.279 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
T SW APARTMENT | 3336.29 | 4003.55 | 0.261 | 0.314 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 17:15:00 | 31.03 | 0.01435 |
T NW APARTMENT | 3262.18 | 3914.62 | 0.256 | 0.307 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 17:45:00 | 30.67 | 0.01435 |
T SE APARTMENT | 2681.03 | 3217.24 | 0.210 | 0.252 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 32.11 | 0.01435 |
T NE APARTMENT | 2507.03 | 3008.44 | 0.196 | 0.236 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 11:30:00 | 30.92 | 0.01435 |
T N1 APARTMENT | 1903.57 | 2284.29 | 0.149 | 0.179 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
T N2 APARTMENT | 1881.90 | 2258.29 | 0.147 | 0.177 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 30.50 | 0.01435 |
T S1 APARTMENT | 2098.98 | 2518.78 | 0.164 | 0.197 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 32.20 | 0.01435 |
T S2 APARTMENT | 2104.32 | 2525.19 | 0.165 | 0.198 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 32.20 | 0.01435 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 0.67 | 0.81 | 0.000 | 0.027 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
G NW APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
OFFICE | 414.78 | 497.73 | 0.012 | 0.038 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:00:00 | 16.20 | 0.01152 |
G NE APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
G N1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
G N2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
G S1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
G S2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M SW APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M NW APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M SE APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M NE APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M N1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M N2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M S1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
M S2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.01152 | |
T SW APARTMENT | 244.36 | 293.23 | 0.007 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T NW APARTMENT | 244.35 | 293.22 | 0.007 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T SE APARTMENT | 245.17 | 294.20 | 0.007 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T NE APARTMENT | 245.15 | 294.18 | 0.007 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T N1 APARTMENT | 18.38 | 22.05 | 0.001 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T N2 APARTMENT | 18.44 | 22.13 | 0.001 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T S1 APARTMENT | 13.26 | 15.91 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
T S2 APARTMENT | 13.37 | 16.04 | 0.000 | 0.026 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 04:00:00 | 16.20 | 0.01152 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.21 | 0.21 | 0.03 | 0.03 |
SPLIT GNW | 0.21 | 0.21 | 0.03 | 0.03 |
SPLIT OFFICE | 0.45 | 0.45 | 0.04 | 0.04 |
SPLIT GNE | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT GN1 | 0.11 | 0.11 | 0.03 | 0.03 |
SPLIT GN2 | 0.11 | 0.11 | 0.03 | 0.03 |
SPLIT GS1 | 0.11 | 0.11 | 0.03 | 0.03 |
SPLIT GS2 | 0.11 | 0.11 | 0.03 | 0.03 |
SPLIT MSW | 0.51 | 0.51 | 0.05 | 0.05 |
SPLIT MNW | 0.50 | 0.50 | 0.05 | 0.05 |
SPLIT MSE | 0.40 | 0.40 | 0.05 | 0.05 |
SPLIT MNE | 0.38 | 0.38 | 0.05 | 0.05 |
SPLIT MN1 | 0.28 | 0.28 | 0.05 | 0.05 |
SPLIT MN2 | 0.28 | 0.28 | 0.05 | 0.05 |
SPLIT MS1 | 0.28 | 0.28 | 0.05 | 0.05 |
SPLIT MS2 | 0.28 | 0.28 | 0.05 | 0.05 |
SPLIT TSW | 0.31 | 0.31 | 0.03 | 0.03 |
SPLIT TNW | 0.31 | 0.31 | 0.03 | 0.03 |
SPLIT TSE | 0.25 | 0.25 | 0.03 | 0.03 |
SPLIT TNE | 0.24 | 0.24 | 0.03 | 0.03 |
SPLIT TN1 | 0.18 | 0.18 | 0.03 | 0.03 |
SPLIT TN2 | 0.18 | 0.18 | 0.03 | 0.03 |
SPLIT TS1 | 0.20 | 0.20 | 0.03 | 0.03 |
SPLIT TS2 | 0.20 | 0.20 | 0.03 | 0.03 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 7998.25 | 1865.75 | 1725.25 |
G NW APARTMENT | 7663.75 | 2454.00 | 2170.00 |
OFFICE | 1408.25 | 49.00 | 0.00 |
G NE APARTMENT | 7736.50 | 2399.00 | 2105.50 |
G N1 APARTMENT | 7448.75 | 3076.25 | 2708.25 |
G N2 APARTMENT | 7451.50 | 3064.00 | 2697.25 |
G S1 APARTMENT | 7813.50 | 2172.75 | 2014.25 |
G S2 APARTMENT | 7787.25 | 2298.00 | 2119.00 |
M SW APARTMENT | 8742.50 | 129.75 | 129.75 |
M NW APARTMENT | 8693.50 | 192.75 | 192.75 |
M SE APARTMENT | 8742.50 | 117.00 | 117.00 |
M NE APARTMENT | 8710.25 | 169.25 | 169.25 |
M N1 APARTMENT | 8705.75 | 167.00 | 167.00 |
M N2 APARTMENT | 8705.50 | 165.75 | 165.75 |
M S1 APARTMENT | 8749.75 | 99.75 | 99.75 |
M S2 APARTMENT | 8749.75 | 98.50 | 98.50 |
T SW APARTMENT | 8563.25 | 406.00 | 390.75 |
T NW APARTMENT | 8485.75 | 578.25 | 554.75 |
T SE APARTMENT | 8575.00 | 375.25 | 357.75 |
T NE APARTMENT | 8505.00 | 586.50 | 559.00 |
T N1 APARTMENT | 8576.00 | 553.75 | 536.25 |
T N2 APARTMENT | 8575.75 | 552.00 | 534.00 |
T S1 APARTMENT | 8640.50 | 329.50 | 321.75 |
T S2 APARTMENT | 8640.50 | 327.50 | 319.75 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 8749.75 | 3241.75 | 2852.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 0.00 | 0.50 | 0.00 | 0.50 |
G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 0.00 | 0.50 | 0.00 | 0.50 |
M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 0.00 | 101.50 | 0.00 | 101.50 |
M S2 APARTMENT | 0.00 | 111.50 | 0.00 | 111.50 |
T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 0.00 | 9.00 | 0.00 | 9.00 |
T S2 APARTMENT | 0.00 | 9.00 | 0.00 | 9.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.00 | 112.00 | 0.00 | 112.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.371 | 0.114 | 0.000 | 0.105 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.114 | 0.000 | 0.114 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.523 | 0.137 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.114 | 0.000 | 0.115 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.069 | 0.000 | 0.114 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.069 | 0.000 | 0.114 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.069 | 0.000 | 0.105 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.069 | 0.000 | 0.105 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.164 | 0.000 | 0.137 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.164 | 0.000 | 0.151 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.164 | 0.000 | 0.137 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.164 | 0.000 | 0.151 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.099 | 0.000 | 0.151 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.099 | 0.000 | 0.151 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.099 | 0.000 | 0.137 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.099 | 0.000 | 0.137 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.217 | 0.000 | 0.180 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.217 | 0.000 | 0.201 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.217 | 0.000 | 0.180 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.217 | 0.000 | 0.201 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.131 | 0.000 | 0.201 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.131 | 0.000 | 0.201 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.131 | 0.000 | 0.180 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.131 | 0.000 | 0.180 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.363 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.514 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.401 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.400 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.350 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 295.89 | 0.00 | 01-JAN-00:15 | 24818.74 | 13-DEC-07:30 |
WaterSystems:Electricity | 295.89 | 0.00 | 01-JAN-00:15 | 24818.74 | 13-DEC-07:30 |
Water Heater:WaterSystems:Electricity | 295.89 | 0.00 | 01-JAN-00:15 | 24818.74 | 13-DEC-07:30 |
Fans:Electricity | 220.22 | 6983.10 | 01-JAN-00:15 | 6983.10 | 05-JAN-08:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
ElectricityPurchased:Plant | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
Cogeneration:ElectricityPurchased | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
ElectricityNet:Plant | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
Cogeneration:ElectricityNet | 1636.84 | 20896.40 | 12-FEB-03:30 | 89071.84 | 05-SEP-17:45 |
ExteriorLights:Electricity | 39.48 | 0.00 | 01-JAN-07:15 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.48 | 0.00 | 01-JAN-07:15 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 625.04 | 7110.75 | 11-FEB-06:15 | 34444.44 | 03-SEP-16:15 |
General:Fans:Electricity | 220.22 | 6983.10 | 01-JAN-00:15 | 6983.10 | 05-JAN-08:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 404.82 | 127.65 | 11-FEB-06:15 | 27461.34 | 03-SEP-16:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Gas:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:Gas | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 2670.58 | 2970.69 | 11-FEB-06:15 | 179498.55 | 03-SEP-16:15 |
EnergyTransfer:Building | 991.45 | 2334.10 | 11-FEB-07:00 | 70709.58 | 03-SEP-16:15 |
EnergyTransfer:Zone:G SW APARTMENT | 21.28 | 0.05 | 09-DEC-06:15 | 2538.11 | 22-SEP-16:30 |
Heating:EnergyTransfer | 1.17 | 0.00 | 01-JAN-09:45 | 1640.87 | 27-APR-05:45 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.18 | 0.00 | 01-JAN-00:15 | 157.78 | 27-MAR-08:45 |
Cooling:EnergyTransfer | 990.28 | 1706.03 | 11-FEB-07:00 | 70709.58 | 03-SEP-16:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 21.10 | 0.00 | 01-JAN-01:45 | 2538.11 | 22-SEP-16:30 |
EnergyTransfer:Zone:G NW APARTMENT | 17.31 | 0.09 | 29-MAY-02:15 | 2258.45 | 04-SEP-17:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.37 | 0.00 | 01-JAN-09:30 | 204.59 | 26-MAR-09:30 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 16.94 | 0.00 | 01-JAN-00:15 | 2258.45 | 04-SEP-17:15 |
EnergyTransfer:Zone:OFFICE | 38.96 | 0.24 | 27-MAR-05:15 | 3755.81 | 16-OCT-10:30 |
Heating:EnergyTransfer:Zone:OFFICE | 0.01 | 0.00 | 01-JAN-00:15 | 209.55 | 27-APR-05:45 |
Cooling:EnergyTransfer:Zone:OFFICE | 38.94 | 0.00 | 07-JAN-07:00 | 3755.81 | 16-OCT-10:30 |
EnergyTransfer:Zone:G NE APARTMENT | 18.62 | 0.03 | 15-JAN-05:15 | 2075.42 | 25-JUN-06:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.17 | 0.00 | 01-JAN-07:30 | 144.29 | 17-FEB-01:15 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 18.44 | 0.00 | 01-JAN-00:15 | 2075.42 | 25-JUN-06:00 |
EnergyTransfer:Zone:G N1 APARTMENT | 12.32 | 0.03 | 08-DEC-06:00 | 1284.55 | 09-JUL-17:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.10 | 0.00 | 01-JAN-01:00 | 152.48 | 28-JAN-10:15 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 12.22 | 0.00 | 01-JAN-00:15 | 1284.55 | 09-JUL-17:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 12.37 | 0.00 | 28-APR-00:45 | 1278.52 | 09-JUL-17:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.09 | 0.00 | 01-JAN-01:00 | 141.94 | 28-MAR-09:45 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 12.28 | 0.00 | 01-JAN-00:15 | 1278.52 | 09-JUL-17:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 16.46 | 0.00 | 20-APR-05:00 | 1601.33 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 100.45 | 17-FEB-03:30 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 16.43 | 0.00 | 08-JAN-04:00 | 1601.33 | 21-NOV-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 16.12 | 0.01 | 29-MAR-01:15 | 1589.91 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 108.02 | 17-FEB-02:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 16.08 | 0.00 | 06-JAN-03:00 | 1589.91 | 21-NOV-13:30 |
EnergyTransfer:Zone:M SW APARTMENT | 79.63 | 16.47 | 08-MAR-07:15 | 6404.36 | 06-NOV-14:30 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 79.63 | 16.47 | 08-MAR-07:15 | 6404.36 | 06-NOV-14:30 |
EnergyTransfer:Zone:M NW APARTMENT | 67.54 | 3.38 | 08-MAR-07:30 | 5474.10 | 04-SEP-17:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 73.42 | 12-FEB-08:30 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 67.53 | 0.00 | 08-FEB-07:30 | 5474.10 | 04-SEP-17:15 |
EnergyTransfer:Zone:M SE APARTMENT | 83.99 | 38.06 | 15-FEB-06:15 | 6181.18 | 15-DEC-11:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 83.99 | 38.06 | 15-FEB-06:15 | 6181.18 | 15-DEC-11:30 |
EnergyTransfer:Zone:M NE APARTMENT | 71.87 | 39.53 | 15-FEB-07:00 | 5346.33 | 27-MAY-06:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 71.87 | 39.53 | 15-FEB-07:00 | 5346.33 | 27-MAY-06:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 56.15 | 179.32 | 12-FEB-08:30 | 3316.60 | 09-JUL-17:15 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 56.15 | 179.32 | 12-FEB-08:30 | 3316.60 | 09-JUL-17:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 56.30 | 180.85 | 12-FEB-08:30 | 3309.30 | 09-JUL-17:15 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 56.30 | 180.85 | 12-FEB-08:30 | 3309.30 | 09-JUL-17:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 68.34 | 348.15 | 08-MAR-07:15 | 4773.58 | 23-DEC-13:30 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 68.34 | 348.15 | 08-MAR-07:15 | 4773.58 | 23-DEC-13:30 |
EnergyTransfer:Zone:M S2 APARTMENT | 68.48 | 349.52 | 08-MAR-07:15 | 4758.22 | 23-DEC-13:45 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 68.48 | 349.52 | 08-MAR-07:15 | 4758.22 | 23-DEC-13:45 |
EnergyTransfer:Zone:T SW APARTMENT | 40.77 | 0.37 | 26-DEC-02:30 | 3898.61 | 11-OCT-14:30 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 230.08 | 27-APR-05:45 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 40.73 | 0.00 | 01-JAN-06:15 | 3898.61 | 11-OCT-14:30 |
EnergyTransfer:Zone:T NW APARTMENT | 35.06 | 0.02 | 29-DEC-05:00 | 3427.63 | 03-SEP-16:15 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 245.13 | 27-APR-06:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 34.99 | 0.00 | 01-JAN-06:15 | 3427.63 | 03-SEP-16:15 |
EnergyTransfer:Zone:T SE APARTMENT | 42.75 | 0.13 | 12-FEB-04:30 | 3716.12 | 15-DEC-11:45 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.02 | 0.00 | 01-JAN-00:15 | 174.97 | 27-APR-05:45 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 42.72 | 0.00 | 01-JAN-06:15 | 3716.12 | 15-DEC-11:45 |
EnergyTransfer:Zone:T NE APARTMENT | 36.99 | 0.01 | 08-FEB-05:15 | 2918.95 | 12-JUL-10:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 167.81 | 27-APR-06:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 36.95 | 0.00 | 01-JAN-06:15 | 2918.95 | 12-JUL-10:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 29.55 | 0.02 | 27-FEB-06:45 | 2192.82 | 03-SEP-16:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 85.29 | 27-APR-06:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 29.55 | 0.00 | 05-JAN-06:30 | 2192.82 | 03-SEP-16:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 29.64 | 0.15 | 17-JAN-06:45 | 2179.37 | 03-SEP-16:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 83.14 | 27-APR-06:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 29.63 | 0.00 | 05-JAN-06:30 | 2179.37 | 03-SEP-16:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 35.45 | 0.23 | 28-MAR-06:00 | 3051.09 | 15-DEC-12:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 90.05 | 27-APR-05:45 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 35.44 | 0.00 | 07-JAN-06:15 | 3051.09 | 15-DEC-12:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 35.53 | 0.16 | 11-FEB-06:45 | 3060.09 | 15-DEC-12:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 90.67 | 27-APR-05:45 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 35.52 | 0.00 | 07-JAN-06:15 | 3060.09 | 15-DEC-12:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 1679.13 | 491.28 | 11-FEB-06:15 | 111379.80 | 15-SEP-17:15 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
CoolingCoils:EnergyTransfer | 1679.13 | 491.28 | 11-FEB-06:15 | 111379.80 | 15-SEP-17:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.184 | -21.095 | 0.000 | 0.000 | 3.521 | 2.413 | 12.213 | 16.167 | 0.000 | 0.806 | 0.000 | 0.000 | -2.169 | 0.000 | -0.529 | -11.510 |
G NW APARTMENT | 0.368 | -16.939 | 0.000 | 0.000 | 3.525 | 2.413 | 12.213 | 11.470 | 0.000 | 0.823 | 0.000 | 0.000 | -2.055 | 0.000 | -0.537 | -11.281 |
OFFICE | 0.012 | -38.943 | 0.000 | 0.000 | 0.517 | 21.914 | 7.534 | 18.350 | 0.000 | 0.742 | 0.000 | 0.000 | -1.871 | 0.000 | -0.167 | -8.087 |
G NE APARTMENT | 0.174 | -18.443 | 0.000 | 0.000 | 3.529 | 2.413 | 12.213 | 13.321 | 0.000 | 0.823 | 0.000 | 0.000 | -1.997 | 0.000 | -0.536 | -11.497 |
G N1 APARTMENT | 0.099 | -12.219 | 0.000 | 0.000 | 3.531 | 2.413 | 12.213 | 5.498 | 0.000 | 0.573 | 0.000 | 0.000 | -1.155 | 0.000 | -0.445 | -10.508 |
G N2 APARTMENT | 0.094 | -12.276 | 0.000 | 0.000 | 3.531 | 2.413 | 12.213 | 5.496 | 0.000 | 0.573 | 0.000 | 0.000 | -1.155 | 0.000 | -0.445 | -10.444 |
G S1 APARTMENT | 0.026 | -16.430 | 0.000 | 0.000 | 3.524 | 2.413 | 12.213 | 10.212 | 0.000 | 0.556 | 0.000 | 0.000 | -1.277 | 0.000 | -0.441 | -10.796 |
G S2 APARTMENT | 0.037 | -16.084 | 0.000 | 0.000 | 3.525 | 2.413 | 12.213 | 10.218 | 0.000 | 0.556 | 0.000 | 0.000 | -1.266 | 0.000 | -0.440 | -11.172 |
M SW APARTMENT | 0.000 | -79.633 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 15.580 | 0.000 | 1.130 | 48.165 | 0.000 | -2.687 | 0.000 | -0.697 | 0.000 |
M NW APARTMENT | 0.001 | -67.534 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 10.885 | 0.000 | 1.155 | 40.707 | 0.000 | -2.632 | 0.000 | -0.725 | 0.000 |
M SE APARTMENT | 0.000 | -83.989 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 17.397 | 0.000 | 1.130 | 50.664 | 0.000 | -2.648 | 0.000 | -0.697 | 0.000 |
M NE APARTMENT | 0.000 | -71.871 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 12.680 | 0.000 | 1.156 | 43.192 | 0.000 | -2.575 | 0.000 | -0.724 | 0.000 |
M N1 APARTMENT | 0.000 | -56.148 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 5.098 | 0.000 | 0.799 | 34.272 | 0.000 | -1.565 | 0.000 | -0.600 | 0.000 |
M N2 APARTMENT | 0.000 | -56.298 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 5.096 | 0.000 | 0.799 | 34.425 | 0.000 | -1.565 | 0.000 | -0.600 | 0.000 |
M S1 APARTMENT | 0.000 | -68.342 | 0.000 | 0.000 | 3.516 | 2.413 | 12.213 | 9.826 | 0.000 | 0.771 | 41.773 | 0.000 | -1.598 | 0.000 | -0.573 | 0.000 |
M S2 APARTMENT | 0.000 | -68.477 | 0.000 | 0.000 | 3.516 | 2.413 | 12.213 | 9.824 | 0.000 | 0.771 | 41.912 | 0.000 | -1.599 | 0.000 | -0.573 | 0.000 |
T SW APARTMENT | 0.043 | -40.730 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 15.098 | 0.000 | 1.510 | 9.430 | 0.000 | -2.615 | 0.000 | -0.879 | -0.001 |
T NW APARTMENT | 0.068 | -34.989 | 0.000 | 0.000 | 3.518 | 2.413 | 12.213 | 10.474 | 0.000 | 1.548 | 8.220 | 0.000 | -2.548 | 0.000 | -0.916 | -0.000 |
T SE APARTMENT | 0.025 | -42.722 | 0.000 | 0.000 | 3.518 | 2.413 | 12.213 | 16.851 | 0.000 | 1.511 | 9.636 | 0.000 | -2.566 | 0.000 | -0.878 | -0.001 |
T NE APARTMENT | 0.034 | -36.954 | 0.000 | 0.000 | 3.518 | 2.413 | 12.213 | 12.208 | 0.000 | 1.549 | 8.417 | 0.000 | -2.482 | 0.000 | -0.915 | -0.001 |
T N1 APARTMENT | 0.003 | -29.550 | 0.000 | 0.000 | 3.518 | 2.413 | 12.213 | 4.914 | 0.000 | 1.083 | 7.649 | 0.000 | -1.492 | 0.000 | -0.750 | -0.000 |
T N2 APARTMENT | 0.003 | -29.632 | 0.000 | 0.000 | 3.518 | 2.413 | 12.213 | 4.910 | 0.000 | 1.083 | 7.732 | 0.000 | -1.492 | 0.000 | -0.749 | -0.000 |
T S1 APARTMENT | 0.002 | -35.443 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 9.557 | 0.000 | 1.045 | 8.986 | 0.000 | -1.578 | 0.000 | -0.712 | -0.000 |
T S2 APARTMENT | 0.002 | -35.523 | 0.000 | 0.000 | 3.517 | 2.413 | 12.213 | 9.555 | 0.000 | 1.045 | 9.068 | 0.000 | -1.578 | 0.000 | -0.712 | -0.000 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.292 | 0.000 | 0.047 | 0.000 | 0.000 | -0.270 | 0.000 | -0.211 | -16.928 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 1.131 | 0.000 | 2.018 | 0.000 | 0.000 | -0.470 | 0.000 | -3.299 | -22.714 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.311 | 0.000 | 0.047 | 0.000 | 0.000 | -0.282 | 0.000 | -0.164 | -16.983 |
Total Facility | 1.175 | -990.266 | 0.000 | 0.000 | 81.476 | 128.627 | 294.692 | 262.419 | 0.000 | 25.651 | 404.248 | 0.000 | -47.185 | 0.000 | -18.917 | -141.923 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 22-SEP-16:30 | 0.00 | -2538.04 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2244.83 | 0.00 | 71.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -595.45 |
G NW APARTMENT | 04-SEP-17:15 | 0.00 | -2259.04 | 0.00 | 0.00 | 141.82 | 194.45 | 588.62 | 1688.61 | 0.00 | 127.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -481.67 |
OFFICE | 16-OCT-10:30 | 0.00 | -3755.72 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 2982.34 | 0.00 | 43.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1504.97 |
G NE APARTMENT | 25-JUN-06:00 | 0.00 | -2074.33 | 0.00 | 0.00 | 162.99 | 100.83 | 317.86 | 5445.35 | 0.00 | 0.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3953.65 |
G N1 APARTMENT | 09-JUL-17:15 | 0.00 | -1285.00 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 475.84 | 0.00 | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -160.65 |
G N2 APARTMENT | 09-JUL-17:15 | 0.00 | -1278.97 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 475.99 | 0.00 | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -166.82 |
G S1 APARTMENT | 21-NOV-13:30 | 0.00 | -1601.29 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2101.04 | 0.00 | 60.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1018.60 |
G S2 APARTMENT | 21-NOV-13:30 | 0.00 | -1589.88 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2101.36 | 0.00 | 60.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1030.33 |
M SW APARTMENT | 06-NOV-14:30 | 0.00 | -6403.99 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2852.31 | 0.00 | 142.69 | 2956.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 04-SEP-17:15 | 0.00 | -5474.38 | 0.00 | 0.00 | 141.82 | 194.45 | 588.62 | 1665.79 | 0.00 | 182.24 | 2701.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 15-DEC-11:30 | 0.00 | -6180.96 | 0.00 | 0.00 | 40.66 | 28.81 | 412.04 | 2806.99 | 0.00 | 104.08 | 2788.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 27-MAY-06:00 | 0.00 | -5343.34 | 0.00 | 0.00 | 162.99 | 100.83 | 317.86 | 5611.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -55.40 | -794.26 |
M N1 APARTMENT | 09-JUL-17:15 | 0.00 | -3317.15 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 460.92 | 0.00 | 64.28 | 1867.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 09-JUL-17:15 | 0.00 | -3309.85 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 460.99 | 0.00 | 64.28 | 1859.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 23-DEC-13:30 | 0.00 | -4773.26 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 1973.81 | 0.00 | 58.72 | 2282.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 23-DEC-13:45 | 0.00 | -4757.96 | 0.00 | 0.00 | 40.71 | 28.81 | 388.49 | 1895.01 | 0.00 | 61.54 | 2343.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 11-OCT-14:30 | 0.00 | -3898.59 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 2541.48 | 0.00 | 146.18 | 719.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 03-SEP-16:06 | 0.00 | -3430.46 | 0.00 | 0.00 | 84.77 | 144.04 | 588.62 | 1698.76 | 0.00 | 239.32 | 674.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 15-DEC-11:45 | 0.00 | -3715.96 | 0.00 | 0.00 | 40.75 | 28.81 | 412.04 | 2606.95 | 0.00 | 138.37 | 489.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 12-JUL-10:15 | 0.00 | -2918.89 | 0.00 | 0.00 | 40.75 | 28.81 | 412.04 | 1640.27 | 0.00 | 138.46 | 658.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 03-SEP-16:06 | 0.00 | -2194.91 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 482.30 | 0.00 | 144.35 | 750.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 03-SEP-16:06 | 0.00 | -2181.46 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 482.62 | 0.00 | 144.35 | 737.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 15-DEC-12:30 | 0.00 | -3051.04 | 0.00 | 0.00 | 40.60 | 28.81 | 406.15 | 2038.05 | 0.00 | 81.99 | 455.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 15-DEC-12:30 | 0.00 | -3060.05 | 0.00 | 0.00 | 40.57 | 28.81 | 406.15 | 2037.49 | 0.00 | 81.82 | 465.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 03-SEP-16:06 | 0.00 | -70768.94 | 0.00 | 0.00 | 1949.54 | 5316.35 | 14071.03 | 22762.10 | 0.00 | 5466.77 | 21203.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 27-MAR-08:45 | 157.78 | 0.00 | 0.00 | 0.00 | 40.81 | 28.81 | 394.38 | 470.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -35.85 | -1056.31 |
G NW APARTMENT | 26-MAR-09:30 | 204.58 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 428.27 | 0.00 | 7.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1115.64 |
OFFICE | 07-JAN-07:04 | 210.19 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 128.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -329.12 | 0.00 | -23.35 | -365.99 |
G NE APARTMENT | 17-FEB-01:15 | 144.33 | 0.00 | 0.00 | 0.00 | 162.99 | 14.40 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -8.53 | 0.00 | -1.74 | -552.79 |
G N1 APARTMENT | 28-JAN-10:15 | 152.46 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 280.20 | 0.00 | 25.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -933.53 |
G N2 APARTMENT | 28-MAR-09:45 | 141.93 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 356.71 | 0.00 | 22.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -996.36 |
G S1 APARTMENT | 17-FEB-03:30 | 100.47 | 0.00 | 0.00 | 0.00 | 162.99 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12.70 | 0.00 | -2.61 | -486.23 |
G S2 APARTMENT | 17-FEB-02:15 | 108.04 | 0.00 | 0.00 | 0.00 | 162.99 | 14.40 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6.04 | 0.00 | -0.75 | -508.21 |
M SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 08-FEB-08:02 | 122.15 | 0.00 | 0.00 | 0.00 | 63.59 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -197.42 | 0.00 | -287.74 | -132.28 |
M SE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 27-APR-05:45 | 230.08 | 0.00 | 0.00 | 0.00 | 163.42 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -278.77 | 0.00 | -512.89 | -20.53 |
T NW APARTMENT | 27-APR-06:00 | 245.12 | 0.00 | 0.00 | 0.00 | 163.76 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 52.10 | 0.00 | -277.36 | 0.00 | -602.31 | 0.00 |
T SE APARTMENT | 27-APR-05:45 | 174.97 | 0.00 | 0.00 | 0.00 | 164.05 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 22.95 | 0.00 | -280.78 | 0.00 | -499.87 | 0.00 |
T NE APARTMENT | 27-APR-06:00 | 167.80 | 0.00 | 0.00 | 0.00 | 165.17 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 105.54 | 0.00 | -277.46 | 0.00 | -579.73 | 0.00 |
T N1 APARTMENT | 27-APR-06:00 | 85.29 | 0.00 | 0.00 | 0.00 | 163.75 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 39.58 | 0.00 | -170.68 | 0.00 | -536.63 | 0.00 |
T N2 APARTMENT | 27-APR-06:00 | 83.14 | 0.00 | 0.00 | 0.00 | 163.80 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 40.86 | 0.00 | -170.59 | 0.00 | -535.89 | 0.00 |
T S1 APARTMENT | 27-APR-05:45 | 90.05 | 0.00 | 0.00 | 0.00 | 163.34 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -174.45 | 0.00 | -455.13 | -42.49 |
T S2 APARTMENT | 27-APR-05:45 | 90.67 | 0.00 | 0.00 | 0.00 | 163.34 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -174.41 | 0.00 | -455.10 | -43.17 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 27-APR-05:45 | -1337.82 | 0.00 | 0.00 | 0.00 | 3786.98 | 4322.48 | 7762.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5301.72 | 0.00 | -8739.89 | -492.63 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Sec1.1A-General InformationData | |
Weather File | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 112.00 |
Number of hours not met | 112.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Cooling | 404.82 | 24976.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 220.22 | 6983.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 295.89 | 22083.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1636.84 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1636.84 |
Natural Gas | 0.00 | 0.00 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1636.84 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 129.15 |
Fans-Interior | 70.25 |
Service Water Heating | 94.40 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.60 |
Subtotal | 522.18 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 10.08 |
Space Heating | 0.00 |
Space Cooling | 24.73 |
Fans-Interior | 13.45 |
Service Water Heating | 18.08 |
Receptacle Equipment | 31.24 |
Miscellaneous | 2.41 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.209754 |
G NW APARTMENT DIRECT AIR | 0.207559 |
OFFICE DIRECT AIR | 0.447454 |
G NE APARTMENT DIRECT AIR | 0.153694 |
G N1 APARTMENT DIRECT AIR | 0.110721 |
G N2 APARTMENT DIRECT AIR | 0.109563 |
G S1 APARTMENT DIRECT AIR | 0.109500 |
G S2 APARTMENT DIRECT AIR | 0.110000 |
M SW APARTMENT DIRECT AIR | 0.509048 |
M NW APARTMENT DIRECT AIR | 0.502079 |
M SE APARTMENT DIRECT AIR | 0.402289 |
M NE APARTMENT DIRECT AIR | 0.384017 |
M N1 APARTMENT DIRECT AIR | 0.280722 |
M N2 APARTMENT DIRECT AIR | 0.278780 |
M S1 APARTMENT DIRECT AIR | 0.281075 |
M S2 APARTMENT DIRECT AIR | 0.279277 |
T SW APARTMENT DIRECT AIR | 0.313601 |
T NW APARTMENT DIRECT AIR | 0.306620 |
T SE APARTMENT DIRECT AIR | 0.252018 |
T NE APARTMENT DIRECT AIR | 0.235664 |
T N1 APARTMENT DIRECT AIR | 0.178913 |
T N2 APARTMENT DIRECT AIR | 0.176877 |
T S1 APARTMENT DIRECT AIR | 0.197291 |
T S2 APARTMENT DIRECT AIR | 0.197793 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.209754 |
SPLIT GNW MAIN BRANCH | 0.207559 |
SPLIT OFFICE MAIN BRANCH | 0.447454 |
SPLIT GNE MAIN BRANCH | 0.153694 |
SPLIT GN1 MAIN BRANCH | 0.110721 |
SPLIT GN2 MAIN BRANCH | 0.109563 |
SPLIT GS1 MAIN BRANCH | 0.109500 |
SPLIT GS2 MAIN BRANCH | 0.110000 |
SPLIT MSW MAIN BRANCH | 0.509048 |
SPLIT MNW MAIN BRANCH | 0.502079 |
SPLIT MSE MAIN BRANCH | 0.402289 |
SPLIT MNE MAIN BRANCH | 0.384017 |
SPLIT MN1 MAIN BRANCH | 0.280722 |
SPLIT MN2 MAIN BRANCH | 0.278780 |
SPLIT MS1 MAIN BRANCH | 0.281075 |
SPLIT MS2 MAIN BRANCH | 0.279277 |
SPLIT TSW MAIN BRANCH | 0.313601 |
SPLIT TNW MAIN BRANCH | 0.306620 |
SPLIT TSE MAIN BRANCH | 0.252018 |
SPLIT TNE MAIN BRANCH | 0.235664 |
SPLIT TN1 MAIN BRANCH | 0.178913 |
SPLIT TN2 MAIN BRANCH | 0.176877 |
SPLIT TS1 MAIN BRANCH | 0.197291 |
SPLIT TS2 MAIN BRANCH | 0.197793 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.209754 |
SPLIT GNW | 0.207559 |
SPLIT OFFICE | 0.447454 |
SPLIT GNE | 0.153694 |
SPLIT GN1 | 0.110721 |
SPLIT GN2 | 0.109563 |
SPLIT GS1 | 0.109500 |
SPLIT GS2 | 0.110000 |
SPLIT MSW | 0.509048 |
SPLIT MNW | 0.502079 |
SPLIT MSE | 0.402289 |
SPLIT MNE | 0.384017 |
SPLIT MN1 | 0.280722 |
SPLIT MN2 | 0.278780 |
SPLIT MS1 | 0.281075 |
SPLIT MS2 | 0.279277 |
SPLIT TSW | 0.313601 |
SPLIT TNW | 0.306620 |
SPLIT TSE | 0.252018 |
SPLIT TNE | 0.235664 |
SPLIT TN1 | 0.178913 |
SPLIT TN2 | 0.176877 |
SPLIT TS1 | 0.197291 |
SPLIT TS2 | 0.197793 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.209754 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.207559 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.447454 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.153694 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.110721 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.109563 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.109500 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.110000 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.509048 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.502079 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.402289 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.384017 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.280722 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.278780 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.281075 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.279277 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.313601 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.306620 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.252018 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.235664 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.178913 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.176877 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.197291 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.197793 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.209754 | 4117.17 | 0.741058 |
SPLIT GNW COOLING COIL | 0.207559 | 4056.69 | 0.742388 |
SPLIT OFFICE COOLING COIL | 0.447454 | 7717.34 | 0.783868 |
SPLIT GNE COOLING COIL | 0.153694 | 3177.03 | 0.725421 |
SPLIT GN1 COOLING COIL | 0.110721 | 2427.09 | 0.708637 |
SPLIT GN2 COOLING COIL | 0.109563 | 2408.06 | 0.707903 |
SPLIT GS1 COOLING COIL | 0.109500 | 2417.48 | 0.706666 |
SPLIT GS2 COOLING COIL | 0.110000 | 2410.01 | 0.708784 |
SPLIT MSW COOLING COIL | 0.509048 | 9769.43 | 0.748118 |
SPLIT MNW COOLING COIL | 0.502079 | 9646.28 | 0.747770 |
SPLIT MSE COOLING COIL | 0.402289 | 8071.79 | 0.734319 |
SPLIT MNE COOLING COIL | 0.384017 | 7717.59 | 0.733831 |
SPLIT MN1 COOLING COIL | 0.280722 | 5889.20 | 0.721103 |
SPLIT MN2 COOLING COIL | 0.278780 | 5857.57 | 0.720651 |
SPLIT MS1 COOLING COIL | 0.281075 | 5919.19 | 0.719995 |
SPLIT MS2 COOLING COIL | 0.279277 | 5889.71 | 0.719585 |
SPLIT TSW COOLING COIL | 0.313601 | 5923.40 | 0.753209 |
SPLIT TNW COOLING COIL | 0.306620 | 5793.45 | 0.753103 |
SPLIT TSE COOLING COIL | 0.252018 | 5000.01 | 0.737756 |
SPLIT TNE COOLING COIL | 0.235664 | 4665.57 | 0.738412 |
SPLIT TN1 COOLING COIL | 0.178913 | 3621.04 | 0.731706 |
SPLIT TN2 COOLING COIL | 0.176877 | 3588.01 | 0.731018 |
SPLIT TS1 COOLING COIL | 0.197291 | 3994.70 | 0.731576 |
SPLIT TS2 COOLING COIL | 0.197793 | 4002.57 | 0.731748 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.209754 | 0.209754 | 0.209754 | 0.209754 | 1099.98 | 4117.17 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.207559 | 0.207559 | 0.207559 | 0.207559 | 1061.31 | 4056.69 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.447454 | 0.447454 | 0.447454 | 0.447454 | 1558.20 | 7717.34 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.153694 | 0.153694 | 0.153694 | 0.153694 | 1061.31 | 3177.03 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.110721 | 0.110721 | 0.110721 | 0.110721 | 1061.31 | 2427.09 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.109563 | 0.109563 | 0.109563 | 0.109563 | 1061.31 | 2408.06 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.109500 | 0.109500 | 0.109500 | 0.109500 | 1061.31 | 2417.48 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.110000 | 0.110000 | 0.110000 | 0.110000 | 1061.31 | 2410.01 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.509048 | 0.509048 | 0.509048 | 0.509048 | 2122.63 | 9769.43 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.502079 | 0.502079 | 0.502079 | 0.502079 | 2122.63 | 9646.28 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.402289 | 0.402289 | 0.402289 | 0.402289 | 2122.63 | 8071.79 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.384017 | 0.384017 | 0.384017 | 0.384017 | 2122.63 | 7717.59 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.280722 | 0.280722 | 0.280722 | 0.280722 | 2122.63 | 5889.20 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.278780 | 0.278780 | 0.278780 | 0.278780 | 2122.63 | 5857.57 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.281075 | 0.281075 | 0.281075 | 0.281075 | 2122.63 | 5919.19 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.279277 | 0.279277 | 0.279277 | 0.279277 | 2122.63 | 5889.71 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.313601 | 0.313601 | 0.313601 | 0.313601 | 1061.31 | 5923.40 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.306620 | 0.306620 | 0.306620 | 0.306620 | 1061.31 | 5793.45 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.252018 | 0.252018 | 0.252018 | 0.252018 | 1061.31 | 5000.01 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.235664 | 0.235664 | 0.235664 | 0.235664 | 1061.31 | 4665.57 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.178913 | 0.178913 | 0.178913 | 0.178913 | 1061.31 | 3621.04 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.176877 | 0.176877 | 0.176877 | 0.176877 | 1061.31 | 3588.01 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.197291 | 0.197291 | 0.197291 | 0.197291 | 1061.31 | 3994.70 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.197793 | 0.197793 | 0.197793 | 0.197793 | 1061.31 | 4002.57 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.209754 |
SPLIT GNW SUPPLY FAN | 0.207559 |
SPLIT OFFICE SUPPLY FAN | 0.447454 |
SPLIT GNE SUPPLY FAN | 0.153694 |
SPLIT GN1 SUPPLY FAN | 0.110721 |
SPLIT GN2 SUPPLY FAN | 0.109563 |
SPLIT GS1 SUPPLY FAN | 0.109500 |
SPLIT GS2 SUPPLY FAN | 0.110000 |
SPLIT MSW SUPPLY FAN | 0.509048 |
SPLIT MNW SUPPLY FAN | 0.502079 |
SPLIT MSE SUPPLY FAN | 0.402289 |
SPLIT MNE SUPPLY FAN | 0.384017 |
SPLIT MN1 SUPPLY FAN | 0.280722 |
SPLIT MN2 SUPPLY FAN | 0.278780 |
SPLIT MS1 SUPPLY FAN | 0.281075 |
SPLIT MS2 SUPPLY FAN | 0.279277 |
SPLIT TSW SUPPLY FAN | 0.313601 |
SPLIT TNW SUPPLY FAN | 0.306620 |
SPLIT TSE SUPPLY FAN | 0.252018 |
SPLIT TNE SUPPLY FAN | 0.235664 |
SPLIT TN1 SUPPLY FAN | 0.178913 |
SPLIT TN2 SUPPLY FAN | 0.176877 |
SPLIT TS1 SUPPLY FAN | 0.197291 |
SPLIT TS2 SUPPLY FAN | 0.197793 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1099.98 |
SPLIT GNW HEATING COIL | 1061.31 |
SPLIT OFFICE HEATING COIL | 1558.20 |
SPLIT GNE HEATING COIL | 1061.31 |
SPLIT GN1 HEATING COIL | 1061.31 |
SPLIT GN2 HEATING COIL | 1061.31 |
SPLIT GS1 HEATING COIL | 1061.31 |
SPLIT GS2 HEATING COIL | 1061.31 |
SPLIT MSW HEATING COIL | 2122.63 |
SPLIT MNW HEATING COIL | 2122.63 |
SPLIT MSE HEATING COIL | 2122.63 |
SPLIT MNE HEATING COIL | 2122.63 |
SPLIT MN1 HEATING COIL | 2122.63 |
SPLIT MN2 HEATING COIL | 2122.63 |
SPLIT MS1 HEATING COIL | 2122.63 |
SPLIT MS2 HEATING COIL | 2122.63 |
SPLIT TSW HEATING COIL | 1061.31 |
SPLIT TNW HEATING COIL | 1061.31 |
SPLIT TSE HEATING COIL | 1061.31 |
SPLIT TNE HEATING COIL | 1061.31 |
SPLIT TN1 HEATING COIL | 1061.31 |
SPLIT TN2 HEATING COIL | 1061.31 |
SPLIT TS1 HEATING COIL | 1061.31 |
SPLIT TS2 HEATING COIL | 1061.31 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:28
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.36 | 22.49 |
February | 24.35 | 22.80 |
March | 24.34 | 23.17 |
April | 24.39 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.39 | 24.76 |
December | 24.39 | 23.69 |
Annual Sum or Average | 24.38 | 24.91 |
Minimum of Months | 24.34 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 22.49 |
February | 24.31 | 22.80 |
March | 24.31 | 23.17 |
April | 24.39 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.38 | 24.76 |
December | 24.37 | 23.69 |
Annual Sum or Average | 24.37 | 24.91 |
Minimum of Months | 24.29 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.90 | 22.49 |
February | 23.90 | 22.80 |
March | 23.90 | 23.17 |
April | 23.90 | 23.76 |
May | 23.90 | 25.23 |
June | 23.90 | 25.87 |
July | 23.90 | 26.90 |
August | 23.90 | 27.06 |
September | 23.90 | 26.87 |
October | 23.90 | 26.22 |
November | 23.90 | 24.76 |
December | 23.90 | 23.69 |
Annual Sum or Average | 23.90 | 24.91 |
Minimum of Months | 23.90 | 22.49 |
Maximum of Months | 23.90 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.27 | 22.49 |
February | 24.27 | 22.80 |
March | 24.28 | 23.17 |
April | 24.38 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.37 | 24.76 |
December | 24.35 | 23.69 |
Annual Sum or Average | 24.36 | 24.91 |
Minimum of Months | 24.27 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.24 | 22.49 |
February | 24.25 | 22.80 |
March | 24.27 | 23.17 |
April | 24.36 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.37 | 24.76 |
December | 24.34 | 23.69 |
Annual Sum or Average | 24.35 | 24.91 |
Minimum of Months | 24.24 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.24 | 22.49 |
February | 24.25 | 22.80 |
March | 24.27 | 23.17 |
April | 24.36 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.37 | 24.76 |
December | 24.34 | 23.69 |
Annual Sum or Average | 24.35 | 24.91 |
Minimum of Months | 24.24 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.34 | 22.49 |
February | 24.33 | 22.80 |
March | 24.31 | 23.17 |
April | 24.37 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.39 | 24.76 |
December | 24.38 | 23.69 |
Annual Sum or Average | 24.38 | 24.91 |
Minimum of Months | 24.31 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.33 | 22.49 |
February | 24.32 | 22.80 |
March | 24.30 | 23.17 |
April | 24.37 | 23.76 |
May | 24.39 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.38 | 24.76 |
December | 24.38 | 23.69 |
Annual Sum or Average | 24.37 | 24.91 |
Minimum of Months | 24.30 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.41 | 26.22 |
November | 24.43 | 24.76 |
December | 24.42 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.43 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.40 | 22.80 |
March | 24.40 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.41 | 26.22 |
November | 24.43 | 24.76 |
December | 24.42 | 23.69 |
Annual Sum or Average | 24.41 | 24.91 |
Minimum of Months | 24.40 | 22.49 |
Maximum of Months | 24.43 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.39 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.39 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.38 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.38 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.38 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.38 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.39 | 22.49 |
February | 24.37 | 22.80 |
March | 24.38 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.39 | 24.91 |
Minimum of Months | 24.37 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.38 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.38 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.38 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.38 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.39 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.39 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.40 | 22.49 |
February | 24.39 | 22.80 |
March | 24.39 | 23.17 |
April | 24.40 | 23.76 |
May | 24.40 | 25.23 |
June | 24.40 | 25.87 |
July | 24.40 | 26.90 |
August | 24.40 | 27.06 |
September | 24.40 | 26.87 |
October | 24.40 | 26.22 |
November | 24.40 | 24.76 |
December | 24.40 | 23.69 |
Annual Sum or Average | 24.40 | 24.91 |
Minimum of Months | 24.39 | 22.49 |
Maximum of Months | 24.40 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.61 | 22.49 |
February | 26.68 | 22.80 |
March | 26.73 | 23.17 |
April | 26.83 | 23.76 |
May | 27.09 | 25.23 |
June | 27.18 | 25.87 |
July | 27.33 | 26.90 |
August | 27.31 | 27.06 |
September | 27.33 | 26.87 |
October | 27.18 | 26.22 |
November | 26.98 | 24.76 |
December | 26.80 | 23.69 |
Annual Sum or Average | 27.00 | 24.91 |
Minimum of Months | 26.61 | 22.49 |
Maximum of Months | 27.33 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.02 | 22.49 |
February | 25.11 | 22.80 |
March | 25.20 | 23.17 |
April | 25.33 | 23.76 |
May | 25.72 | 25.23 |
June | 26.62 | 25.87 |
July | 26.97 | 26.90 |
August | 27.01 | 27.06 |
September | 26.99 | 26.87 |
October | 26.11 | 26.22 |
November | 25.66 | 24.76 |
December | 25.36 | 23.69 |
Annual Sum or Average | 25.93 | 24.91 |
Minimum of Months | 25.02 | 22.49 |
Maximum of Months | 27.01 | 27.06 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:28
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.89 | 22.49 |
February | 26.92 | 22.80 |
March | 26.93 | 23.17 |
April | 26.95 | 23.76 |
May | 27.07 | 25.23 |
June | 27.13 | 25.87 |
July | 27.20 | 26.90 |
August | 27.19 | 27.06 |
September | 27.23 | 26.87 |
October | 27.18 | 26.22 |
November | 27.08 | 24.76 |
December | 26.99 | 23.69 |
Annual Sum or Average | 27.06 | 24.91 |
Minimum of Months | 26.89 | 22.49 |
Maximum of Months | 27.23 | 27.06 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:28
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.130850E+12 | 82992.168 | 03-JAN-18:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 15314.754 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23156.799 | 0.000 | 0.000 | 0.000 |
February | 0.120839E+12 | 79091.474 | 17-FEB-18:30 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 17392.887 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17177.971 | 0.000 | 0.000 | 0.000 |
March | 0.132566E+12 | 82583.420 | 17-MAR-17:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 19426.334 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21144.801 | 0.000 | 0.000 | 0.000 |
April | 0.127966E+12 | 78496.495 | 10-APR-17:00 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 16616.369 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19867.841 | 0.000 | 0.000 | 0.000 |
May | 0.137465E+12 | 78776.686 | 26-MAY-17:45 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 17658.335 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19106.067 | 0.000 | 0.000 | 0.000 |
June | 0.137183E+12 | 82158.201 | 26-JUN-17:30 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 20805.585 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19340.331 | 0.000 | 0.000 | 0.000 |
July | 0.145764E+12 | 84816.614 | 05-JUL-17:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 21952.455 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20851.874 | 0.000 | 0.000 | 0.000 |
August | 0.146061E+12 | 85493.256 | 28-AUG-17:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 21530.479 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21950.492 | 0.000 | 0.000 | 0.000 |
September | 0.143167E+12 | 89071.835 | 05-SEP-17:45 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 24976.184 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22083.366 | 0.000 | 0.000 | 0.000 |
October | 0.143774E+12 | 84049.270 | 13-OCT-16:15 | 7009.952 | 26456.413 | 6983.097 | 0.000 | 22610.535 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20989.273 | 0.000 | 0.000 | 0.000 |
November | 0.135342E+12 | 83802.867 | 06-NOV-18:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 17151.485 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22130.767 | 0.000 | 0.000 | 0.000 |
December | 0.135862E+12 | 82875.477 | 12-DEC-18:15 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 16200.638 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22154.223 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.163684E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.120839E+12 | 78496.495 | 7009.952 | 26456.413 | 6983.097 | 0.000 | 15314.754 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17177.971 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.146061E+12 | 89071.835 | 8572.775 | 26456.413 | 6983.097 | 0.000 | 24976.184 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23156.799 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:28
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.000 | 0.000 | 01-FEB-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.000 | 0.000 | 01-MAR-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.000 | 0.000 | 01-APR-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.000 | 0.000 | 01-MAY-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.000 | 0.000 | 01-OCT-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.000 | 0.000 | 01-NOV-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.000 | 0.000 | 01-DEC-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |