Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2018-10-19 09:20:31
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2202.10 | 702.51 | 779.79 |
Net Site Energy | 2202.10 | 702.51 | 779.79 |
Total Source Energy | 5439.82 | 1735.40 | 1926.30 |
Net Source Energy | 5439.82 | 1735.40 | 1926.30 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 736.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 74.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 207.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 467.85 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1465.55 | 736.55 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 736.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 74.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 207.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 467.85 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 265.49 | 260.82 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 518.97 | 260.82 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 239.18 | 234.97 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 467.54 | 234.97 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1465.55 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1465.55 | 100.00 |
Total On-Site and Utility Electric Sources | 1465.55 | 100.00 |
Total Electricity End Uses | 1465.55 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 33.00 |
Time Setpoint Not Met During Occupied Cooling | 4.75 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 4097.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-JUN-17:30 | 04-JAN-05:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 133527.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 23830.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6585.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 26850.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 92295.01 | 133527.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 133527.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 23830.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6585.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 26850.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 798.42 | 0.00 | 0.00 | 0.00 |
Cooling | 235.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.72 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 657.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1481.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4641.40 | 798.42 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 282.73 | 0.00 | 0.00 | 0.00 |
Cooling | 83.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 232.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 524.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1643.57 | 282.73 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 282.73 | 0.00 | 0.00 | 0.00 |
Cooling | 83.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 232.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 524.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1643.57 | 282.73 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.42_SHGC_0.45 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.493 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.493 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.493 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.493 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.493 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.64 | 83.64 | 39.38 | |
Exterior Lighting Total | 2508.33 | 39.38 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2852.73 | 2194.50 | 658.24 | 0.77 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2631.97 | 2024.80 | 607.18 | 0.77 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7265.92 | 5802.97 | 1462.95 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1938.11 | 1456.36 | 481.75 | 0.75 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1680.49 | 1255.44 | 425.05 | 0.75 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1663.67 | 1241.52 | 422.15 | 0.75 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2089.71 | 1536.10 | 553.61 | 0.74 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2134.84 | 1575.65 | 559.20 | 0.74 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7862.37 | 6175.51 | 1686.86 | 0.79 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7204.60 | 5646.99 | 1557.62 | 0.78 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7391.42 | 5688.25 | 1703.17 | 0.77 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5629.85 | 4349.95 | 1279.89 | 0.77 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4746.07 | 3653.92 | 1092.14 | 0.77 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4717.02 | 3629.65 | 1087.38 | 0.77 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5921.50 | 4495.09 | 1426.41 | 0.76 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5928.24 | 4505.92 | 1422.32 | 0.76 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5190.96 | 4078.16 | 1112.80 | 0.79 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4580.55 | 3615.35 | 965.20 | 0.79 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4923.47 | 3845.25 | 1078.21 | 0.78 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3789.52 | 2899.91 | 889.61 | 0.77 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3001.73 | 2330.85 | 670.88 | 0.78 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2968.82 | 2303.33 | 665.49 | 0.78 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4174.64 | 3246.52 | 928.11 | 0.78 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4188.61 | 3258.19 | 930.42 | 0.78 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2728.3 | 3.18 | 10.85 | 11.28 | 10.63 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2517.2 | 3.18 | 10.85 | 11.28 | 10.63 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6921.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1858.0 | 3.21 | 10.95 | 11.40 | 10.79 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1611.9 | 3.22 | 10.98 | 11.42 | 10.83 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1596.0 | 3.22 | 10.99 | 11.43 | 10.84 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2007.7 | 3.24 | 11.05 | 11.51 | 10.94 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2050.2 | 3.23 | 11.04 | 11.49 | 10.91 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7503.3 | 3.15 | 10.75 | 11.17 | 10.49 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6877.1 | 3.15 | 10.76 | 11.18 | 10.50 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7068.8 | 3.18 | 10.84 | 11.28 | 10.63 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5381.9 | 3.17 | 10.83 | 11.26 | 10.60 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4538.7 | 3.18 | 10.84 | 11.27 | 10.62 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4511.2 | 3.18 | 10.84 | 11.28 | 10.63 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5670.9 | 3.20 | 10.91 | 11.34 | 10.72 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5676.6 | 3.19 | 10.90 | 11.34 | 10.71 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4953.8 | 3.15 | 10.75 | 11.17 | 10.49 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4369.2 | 3.14 | 10.73 | 11.15 | 10.46 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4701.4 | 3.16 | 10.78 | 11.20 | 10.53 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3626.2 | 3.19 | 10.87 | 11.30 | 10.67 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2868.1 | 3.17 | 10.80 | 11.23 | 10.57 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2836.9 | 3.17 | 10.81 | 11.24 | 10.57 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3988.1 | 3.16 | 10.80 | 11.22 | 10.56 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4001.4 | 3.16 | 10.79 | 11.22 | 10.55 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 4027.69 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 3954.03 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 7039.97 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 3942.11 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 3126.02 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 3125.76 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 3143.66 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 3280.44 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 7524.13 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 7481.90 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 7492.93 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 7450.66 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 5459.39 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 5458.65 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 5504.87 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 5504.14 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 5731.77 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 5711.44 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 5715.06 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 5694.71 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 4647.24 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 4646.83 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 4666.35 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 4665.94 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.16 | 177.60 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 163.88 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 491.65 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 114.30 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.09 | 97.76 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.09 | 96.53 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 116.95 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 120.65 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.46 | 512.91 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 467.81 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 460.59 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 354.01 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 296.02 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 293.85 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 357.59 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 359.05 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 338.80 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 302.05 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 317.16 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 233.12 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 190.87 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 188.42 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 266.36 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 267.40 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1616.85 | 1940.22 | 0.132 | 0.159 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 27.12 | 0.01270 |
G NW APARTMENT | 1491.92 | 1790.30 | 0.122 | 0.146 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 26.19 | 0.01270 |
OFFICE | 4387.22 | 5264.67 | 0.366 | 0.439 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.28 | 0.01270 |
G NE APARTMENT | 1040.57 | 1248.68 | 0.085 | 0.102 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26 | 0.01270 |
G N1 APARTMENT | 889.95 | 1067.94 | 0.073 | 0.087 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
G N2 APARTMENT | 878.78 | 1054.54 | 0.072 | 0.086 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
G S1 APARTMENT | 1064.68 | 1277.62 | 0.087 | 0.104 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
G S2 APARTMENT | 1098.35 | 1318.02 | 0.090 | 0.108 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
M SW APARTMENT | 4669.40 | 5603.29 | 0.382 | 0.458 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 27.12 | 0.01270 |
M NW APARTMENT | 4258.83 | 5110.60 | 0.348 | 0.418 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 26.19 | 0.01270 |
M SE APARTMENT | 4192.95 | 5031.54 | 0.343 | 0.411 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
M NE APARTMENT | 3222.69 | 3867.23 | 0.263 | 0.316 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
M N1 APARTMENT | 2694.87 | 3233.84 | 0.220 | 0.264 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
M N2 APARTMENT | 2675.17 | 3210.20 | 0.219 | 0.262 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
M S1 APARTMENT | 3255.39 | 3906.47 | 0.266 | 0.319 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
M S2 APARTMENT | 3268.67 | 3922.40 | 0.267 | 0.321 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
T SW APARTMENT | 3084.21 | 3701.05 | 0.252 | 0.302 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 29.54 | 0.01270 |
T NW APARTMENT | 2749.72 | 3299.66 | 0.225 | 0.270 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 27.12 | 0.01270 |
T SE APARTMENT | 2887.15 | 3464.58 | 0.236 | 0.283 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
T NE APARTMENT | 2122.13 | 2546.56 | 0.173 | 0.208 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 30.10 | 0.01270 |
T N1 APARTMENT | 1737.69 | 2085.23 | 0.142 | 0.170 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 26.19 | 0.01270 |
T N2 APARTMENT | 1715.36 | 2058.43 | 0.140 | 0.168 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 26.19 | 0.01270 |
T S1 APARTMENT | 2424.85 | 2909.82 | 0.198 | 0.238 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
T S2 APARTMENT | 2434.31 | 2921.17 | 0.199 | 0.239 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1971.21 | 2365.45 | 0.059 | 0.071 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G NW APARTMENT | 1959.34 | 2351.21 | 0.059 | 0.071 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
OFFICE | 3969.12 | 4762.94 | 0.115 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G NE APARTMENT | 1949.27 | 2339.12 | 0.059 | 0.070 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G N1 APARTMENT | 1259.13 | 1510.96 | 0.038 | 0.045 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G N2 APARTMENT | 1258.91 | 1510.69 | 0.038 | 0.045 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G S1 APARTMENT | 1274.05 | 1528.86 | 0.038 | 0.046 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G S2 APARTMENT | 1389.72 | 1667.66 | 0.042 | 0.050 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
M SW APARTMENT | 3594.09 | 4312.91 | 0.108 | 0.130 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M NW APARTMENT | 3558.38 | 4270.06 | 0.107 | 0.128 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M SE APARTMENT | 3567.71 | 4281.25 | 0.107 | 0.129 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M NE APARTMENT | 3531.96 | 4238.35 | 0.106 | 0.127 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M N1 APARTMENT | 1848.00 | 2217.60 | 0.055 | 0.067 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M N2 APARTMENT | 1847.38 | 2216.85 | 0.055 | 0.067 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M S1 APARTMENT | 1886.46 | 2263.75 | 0.057 | 0.068 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
M S2 APARTMENT | 1885.84 | 2263.01 | 0.057 | 0.068 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T SW APARTMENT | 3462.75 | 4155.30 | 0.104 | 0.125 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T NW APARTMENT | 3445.55 | 4134.67 | 0.103 | 0.124 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T SE APARTMENT | 3448.61 | 4138.34 | 0.104 | 0.124 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T NE APARTMENT | 3431.41 | 4117.69 | 0.103 | 0.124 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T N1 APARTMENT | 2545.58 | 3054.70 | 0.076 | 0.092 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T N2 APARTMENT | 2545.24 | 3054.28 | 0.076 | 0.092 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T S1 APARTMENT | 2561.74 | 3074.09 | 0.077 | 0.092 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
T S2 APARTMENT | 2561.40 | 3073.68 | 0.077 | 0.092 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -32.70 | 0.00018 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.16 | 0.16 | 0.07 | 0.07 |
SPLIT GNW | 0.15 | 0.15 | 0.07 | 0.07 |
SPLIT OFFICE | 0.44 | 0.44 | 0.14 | 0.14 |
SPLIT GNE | 0.10 | 0.10 | 0.07 | 0.07 |
SPLIT GN1 | 0.09 | 0.09 | 0.05 | 0.05 |
SPLIT GN2 | 0.09 | 0.09 | 0.05 | 0.05 |
SPLIT GS1 | 0.10 | 0.10 | 0.05 | 0.05 |
SPLIT GS2 | 0.11 | 0.11 | 0.05 | 0.05 |
SPLIT MSW | 0.46 | 0.46 | 0.13 | 0.13 |
SPLIT MNW | 0.42 | 0.42 | 0.13 | 0.13 |
SPLIT MSE | 0.41 | 0.41 | 0.13 | 0.13 |
SPLIT MNE | 0.32 | 0.32 | 0.13 | 0.13 |
SPLIT MN1 | 0.26 | 0.26 | 0.07 | 0.07 |
SPLIT MN2 | 0.26 | 0.26 | 0.07 | 0.07 |
SPLIT MS1 | 0.32 | 0.32 | 0.07 | 0.07 |
SPLIT MS2 | 0.32 | 0.32 | 0.07 | 0.07 |
SPLIT TSW | 0.30 | 0.30 | 0.12 | 0.12 |
SPLIT TNW | 0.27 | 0.27 | 0.12 | 0.12 |
SPLIT TSE | 0.28 | 0.28 | 0.12 | 0.12 |
SPLIT TNE | 0.21 | 0.21 | 0.12 | 0.12 |
SPLIT TN1 | 0.17 | 0.17 | 0.09 | 0.09 |
SPLIT TN2 | 0.17 | 0.17 | 0.09 | 0.09 |
SPLIT TS1 | 0.24 | 0.24 | 0.09 | 0.09 |
SPLIT TS2 | 0.24 | 0.24 | 0.09 | 0.09 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 4290.25 | 6665.25 | 2988.75 |
G NW APARTMENT | 4631.50 | 6937.00 | 3529.50 |
OFFICE | 795.50 | 1658.50 | 655.75 |
G NE APARTMENT | 4607.50 | 7045.50 | 3552.75 |
G N1 APARTMENT | 4072.25 | 7135.00 | 3213.50 |
G N2 APARTMENT | 4070.75 | 7138.25 | 3217.50 |
G S1 APARTMENT | 3590.00 | 6701.50 | 2438.25 |
G S2 APARTMENT | 3751.25 | 6743.25 | 2652.25 |
M SW APARTMENT | 3907.00 | 5102.75 | 1437.00 |
M NW APARTMENT | 4346.25 | 5538.00 | 2081.75 |
M SE APARTMENT | 3897.00 | 5113.50 | 1416.75 |
M NE APARTMENT | 4379.25 | 5574.50 | 2092.00 |
M N1 APARTMENT | 3702.25 | 5455.00 | 1533.00 |
M N2 APARTMENT | 3701.25 | 5461.75 | 1532.00 |
M S1 APARTMENT | 2870.00 | 4944.50 | 489.00 |
M S2 APARTMENT | 2875.25 | 4944.25 | 490.50 |
T SW APARTMENT | 5213.00 | 5886.75 | 3188.75 |
T NW APARTMENT | 5513.25 | 6209.50 | 3703.00 |
T SE APARTMENT | 5202.50 | 5885.50 | 3164.75 |
T NE APARTMENT | 5499.00 | 6288.50 | 3701.50 |
T N1 APARTMENT | 5219.50 | 6285.00 | 3439.25 |
T N2 APARTMENT | 5219.00 | 6296.50 | 3443.50 |
T S1 APARTMENT | 4835.50 | 5837.50 | 2835.25 |
T S2 APARTMENT | 4836.00 | 5836.50 | 2834.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6390.75 | 7268.75 | 4097.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
G NW APARTMENT | 5.50 | 0.00 | 5.50 | 0.00 |
OFFICE | 23.50 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
G N1 APARTMENT | 3.00 | 0.25 | 3.00 | 0.25 |
G N2 APARTMENT | 1.75 | 0.25 | 1.75 | 0.25 |
G S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
G S2 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M SW APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
M NW APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
M SE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M NE APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M N1 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M N2 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
M S1 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M S2 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
T SW APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T NW APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T SE APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T NE APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T N1 APARTMENT | 3.00 | 3.75 | 3.00 | 3.75 |
T N2 APARTMENT | 3.25 | 4.50 | 3.25 | 4.50 |
T S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T S2 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 56.50 | 4.75 | 33.00 | 4.75 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.366 | 0.098 | 0.000 | 0.063 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.098 | 0.000 | 0.060 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.518 | 0.119 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.098 | 0.000 | 0.060 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.059 | 0.000 | 0.060 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.059 | 0.000 | 0.060 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.059 | 0.000 | 0.062 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.059 | 0.000 | 0.062 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.141 | 0.000 | 0.076 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.141 | 0.000 | 0.072 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.141 | 0.000 | 0.076 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.141 | 0.000 | 0.072 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.085 | 0.000 | 0.072 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.085 | 0.000 | 0.072 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.085 | 0.000 | 0.076 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.085 | 0.000 | 0.076 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.090 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.086 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.090 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.086 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.113 | 0.000 | 0.085 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.113 | 0.000 | 0.085 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.113 | 0.000 | 0.090 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.113 | 0.000 | 0.090 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.499 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.362 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 467.85 | 0.00 | 01-JAN-00:15 | 33119.05 | 27-FEB-07:15 |
WaterSystems:Electricity | 467.85 | 0.00 | 01-JAN-00:15 | 33119.05 | 27-FEB-07:15 |
Water Heater:WaterSystems:Electricity | 467.85 | 0.00 | 01-JAN-00:15 | 33119.05 | 27-FEB-07:15 |
Fans:Electricity | 207.67 | 6585.31 | 04-JAN-03:00 | 6585.31 | 01-JAN-06:30 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
ElectricityPurchased:Plant | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
Cogeneration:ElectricityPurchased | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
ElectricityNet:Plant | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
Cogeneration:ElectricityNet | 1465.55 | 19955.61 | 01-JAN-03:15 | 92295.01 | 29-JUN-17:30 |
ExteriorLights:Electricity | 39.38 | 0.00 | 01-JAN-08:15 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.38 | 0.00 | 01-JAN-08:15 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 281.90 | 6585.31 | 04-JAN-03:00 | 31511.87 | 29-JUN-16:00 |
General:Fans:Electricity | 207.67 | 6585.31 | 04-JAN-03:00 | 6585.31 | 01-JAN-06:30 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 74.23 | 0.00 | 01-JAN-00:15 | 24926.56 | 29-JUN-16:00 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 736.55 | 0.00 | 10-APR-15:30 | 133527.51 | 04-JAN-06:00 |
Gas:HVAC | 736.55 | 0.00 | 10-APR-15:30 | 133527.51 | 04-JAN-06:00 |
Heating:Gas | 736.55 | 0.00 | 10-APR-15:30 | 133527.51 | 04-JAN-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1484.04 | 1403.36 | 07-OCT-13:15 | 170995.94 | 04-JAN-06:00 |
EnergyTransfer:Building | 591.12 | 1351.82 | 07-OCT-13:30 | 64173.93 | 04-JAN-06:00 |
EnergyTransfer:Zone:G SW APARTMENT | 14.99 | 0.02 | 16-MAY-09:15 | 2012.06 | 04-JAN-08:15 |
Heating:EnergyTransfer | 266.88 | 0.00 | 19-MAR-16:15 | 64173.93 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 9.08 | 0.00 | 06-JAN-14:00 | 2012.06 | 04-JAN-08:15 |
Cooling:EnergyTransfer | 324.24 | 0.00 | 01-JAN-07:45 | 58613.96 | 30-JUN-17:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 5.92 | 0.00 | 01-JAN-00:15 | 1759.50 | 01-SEP-15:30 |
EnergyTransfer:Zone:G NW APARTMENT | 15.96 | 0.01 | 23-APR-00:45 | 2275.04 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 11.66 | 0.00 | 08-FEB-16:15 | 2275.04 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.30 | 0.00 | 01-JAN-00:15 | 1621.49 | 30-JUN-18:15 |
EnergyTransfer:Zone:OFFICE | 22.18 | 0.19 | 07-OCT-11:00 | 4284.30 | 24-DEC-07:30 |
Heating:EnergyTransfer:Zone:OFFICE | 1.08 | 0.00 | 01-JAN-00:15 | 4284.30 | 24-DEC-07:30 |
Cooling:EnergyTransfer:Zone:OFFICE | 21.10 | 0.00 | 01-JAN-07:45 | 3142.68 | 24-JUL-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 15.99 | 0.19 | 15-MAY-19:15 | 2180.56 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 11.53 | 0.00 | 19-MAR-16:15 | 2180.56 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.46 | 0.00 | 01-JAN-00:15 | 1116.90 | 29-JUN-19:00 |
EnergyTransfer:Zone:G N1 APARTMENT | 10.58 | 0.04 | 28-MAY-11:30 | 1383.72 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 6.38 | 0.00 | 29-JAN-17:15 | 1383.72 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 4.21 | 0.00 | 01-JAN-00:15 | 932.94 | 29-JUN-19:00 |
EnergyTransfer:Zone:G N2 APARTMENT | 10.58 | 0.02 | 08-OCT-00:15 | 1380.23 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 6.37 | 0.00 | 04-FEB-18:15 | 1380.23 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 4.20 | 0.00 | 01-JAN-00:15 | 920.73 | 29-JUN-19:00 |
EnergyTransfer:Zone:G S1 APARTMENT | 10.20 | 0.04 | 26-MAR-23:15 | 1216.50 | 04-JAN-08:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 4.22 | 0.00 | 01-JAN-11:45 | 1216.50 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 5.97 | 0.00 | 01-JAN-00:15 | 1212.08 | 01-SEP-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 10.90 | 0.03 | 17-MAY-08:45 | 1317.39 | 04-JAN-08:15 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 5.14 | 0.00 | 02-JAN-11:30 | 1317.39 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 5.76 | 0.00 | 01-JAN-00:15 | 1194.56 | 01-SEP-13:30 |
EnergyTransfer:Zone:M SW APARTMENT | 38.88 | 0.08 | 26-APR-14:00 | 5156.54 | 30-JUN-17:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 11.46 | 0.00 | 02-JAN-11:45 | 4127.42 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 27.42 | 0.00 | 01-JAN-00:15 | 5156.54 | 30-JUN-17:15 |
EnergyTransfer:Zone:M NW APARTMENT | 37.39 | 0.15 | 22-APR-13:15 | 4875.86 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 17.25 | 0.00 | 29-JAN-16:15 | 4875.86 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 20.13 | 0.00 | 01-JAN-00:15 | 4793.31 | 30-JUN-18:15 |
EnergyTransfer:Zone:M SE APARTMENT | 38.89 | 0.04 | 22-MAR-12:30 | 4276.04 | 24-JUL-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 11.32 | 0.00 | 02-JAN-09:30 | 4104.81 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 27.58 | 0.00 | 01-JAN-00:15 | 4276.04 | 24-JUL-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 37.51 | 0.02 | 21-OCT-14:00 | 4666.41 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 17.09 | 0.00 | 17-JAN-13:00 | 4666.41 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 20.42 | 0.00 | 01-JAN-00:15 | 3579.61 | 29-JUN-18:45 |
EnergyTransfer:Zone:M N1 APARTMENT | 26.62 | 0.02 | 22-NOV-15:30 | 2996.88 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 6.04 | 0.00 | 10-JAN-18:15 | 2550.37 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.58 | 0.00 | 01-JAN-00:15 | 2996.88 | 30-JUN-18:45 |
EnergyTransfer:Zone:M N2 APARTMENT | 26.59 | 0.31 | 21-OCT-13:00 | 2968.68 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 6.03 | 0.00 | 10-JAN-18:15 | 2544.15 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.56 | 0.00 | 01-JAN-00:15 | 2968.68 | 30-JUN-18:45 |
EnergyTransfer:Zone:M S1 APARTMENT | 32.64 | 0.20 | 07-NOV-06:45 | 3720.80 | 01-SEP-15:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 2.73 | 0.00 | 01-JAN-10:00 | 1905.82 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 29.91 | 0.00 | 01-JAN-00:15 | 3720.80 | 01-SEP-15:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 32.64 | 0.01 | 03-MAR-05:45 | 3716.74 | 01-SEP-15:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 2.74 | 0.00 | 01-JAN-10:00 | 1905.28 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 29.91 | 0.00 | 01-JAN-00:15 | 3716.74 | 01-SEP-15:15 |
EnergyTransfer:Zone:T SW APARTMENT | 29.65 | 0.07 | 01-AUG-08:45 | 4039.44 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 19.04 | 0.00 | 06-JAN-14:00 | 4039.44 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 10.61 | 0.00 | 01-JAN-00:15 | 3422.80 | 29-JUN-16:15 |
EnergyTransfer:Zone:T NW APARTMENT | 30.70 | 0.03 | 27-SEP-06:00 | 4118.29 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 22.71 | 0.00 | 08-FEB-14:00 | 4118.29 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 7.99 | 0.00 | 01-JAN-00:15 | 3196.76 | 29-JUN-17:30 |
EnergyTransfer:Zone:T SE APARTMENT | 29.43 | 0.01 | 14-AUG-11:00 | 4026.72 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 18.88 | 0.00 | 13-JAN-12:00 | 4026.72 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 10.55 | 0.00 | 01-JAN-00:15 | 2989.08 | 30-JUN-14:15 |
EnergyTransfer:Zone:T NE APARTMENT | 30.59 | 0.04 | 16-APR-12:00 | 4105.33 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 22.55 | 0.00 | 17-MAR-15:30 | 4105.33 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 8.04 | 0.00 | 01-JAN-00:15 | 2448.96 | 29-JUN-16:30 |
EnergyTransfer:Zone:T N1 APARTMENT | 22.36 | 0.04 | 11-SEP-13:00 | 2838.47 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 15.09 | 0.00 | 08-FEB-14:00 | 2838.47 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.28 | 0.00 | 01-JAN-00:15 | 2096.75 | 30-JUN-17:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 22.37 | 0.04 | 04-OCT-12:00 | 2838.38 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 15.10 | 0.00 | 08-FEB-14:00 | 2838.38 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.28 | 0.00 | 01-JAN-00:15 | 2075.17 | 30-JUN-17:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 21.74 | 0.47 | 27-OCT-06:00 | 2755.52 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 11.71 | 0.00 | 02-JAN-12:15 | 2755.52 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 10.04 | 0.00 | 01-JAN-00:15 | 2569.32 | 30-JUN-14:15 |
EnergyTransfer:Zone:T S2 APARTMENT | 21.75 | 0.04 | 09-MAY-02:00 | 2755.44 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 11.71 | 0.00 | 02-JAN-11:45 | 2755.44 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 10.04 | 0.00 | 01-JAN-00:15 | 2572.81 | 01-SEP-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 892.92 | 0.00 | 29-APR-17:30 | 106822.01 | 04-JAN-06:00 |
HeatingCoils:EnergyTransfer | 589.24 | 0.00 | 10-APR-15:30 | 106822.01 | 04-JAN-06:00 |
CoolingCoils:EnergyTransfer | 303.68 | 0.00 | 01-JAN-00:15 | 96514.40 | 30-JUN-15:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 9.076 | -5.916 | 0.000 | 0.000 | 3.889 | 2.413 | 12.213 | 11.163 | 0.000 | 0.050 | 0.000 | 0.000 | -10.574 | 0.000 | -6.003 | -16.311 |
G NW APARTMENT | 11.658 | -4.302 | 0.000 | 0.000 | 3.902 | 2.413 | 12.213 | 5.306 | 0.000 | 0.049 | 0.000 | 0.000 | -11.530 | 0.000 | -5.935 | -13.775 |
OFFICE | 1.082 | -21.101 | 0.000 | 0.000 | 0.544 | 21.914 | 7.534 | 11.190 | 0.000 | 0.038 | 0.000 | 0.000 | -9.676 | 0.000 | -4.883 | -6.642 |
G NE APARTMENT | 11.530 | -4.456 | 0.000 | 0.000 | 3.912 | 2.413 | 12.213 | 5.154 | 0.000 | 0.049 | 0.000 | 0.000 | -11.307 | 0.000 | -5.924 | -13.583 |
G N1 APARTMENT | 6.378 | -4.205 | 0.000 | 0.000 | 3.909 | 2.413 | 12.213 | 1.816 | 0.000 | 0.037 | 0.000 | 0.000 | -7.254 | 0.000 | -3.830 | -11.476 |
G N2 APARTMENT | 6.373 | -4.204 | 0.000 | 0.000 | 3.909 | 2.413 | 12.213 | 1.816 | 0.000 | 0.037 | 0.000 | 0.000 | -7.253 | 0.000 | -3.830 | -11.475 |
G S1 APARTMENT | 4.224 | -5.973 | 0.000 | 0.000 | 3.890 | 2.413 | 12.213 | 7.798 | 0.000 | 0.037 | 0.000 | 0.000 | -6.386 | 0.000 | -3.904 | -14.312 |
G S2 APARTMENT | 5.137 | -5.759 | 0.000 | 0.000 | 3.890 | 2.413 | 12.213 | 7.802 | 0.000 | 0.037 | 0.000 | 0.000 | -6.369 | 0.000 | -3.904 | -15.460 |
M SW APARTMENT | 11.455 | -27.420 | 0.000 | 0.000 | 3.806 | 2.413 | 12.213 | 10.786 | 0.000 | 0.068 | 6.470 | 0.000 | -11.196 | 0.000 | -8.596 | -0.000 |
M NW APARTMENT | 17.253 | -20.132 | 0.000 | 0.000 | 3.830 | 2.413 | 12.213 | 5.015 | 0.000 | 0.066 | 0.000 | 0.000 | -12.134 | 0.000 | -8.515 | -0.009 |
M SE APARTMENT | 11.315 | -27.576 | 0.000 | 0.000 | 3.810 | 2.413 | 12.213 | 10.676 | 0.000 | 0.068 | 6.688 | 0.000 | -11.015 | 0.000 | -8.593 | -0.000 |
M NE APARTMENT | 17.086 | -20.423 | 0.000 | 0.000 | 3.838 | 2.413 | 12.213 | 4.855 | 0.000 | 0.066 | 0.351 | 0.000 | -11.892 | 0.000 | -8.506 | -0.000 |
M N1 APARTMENT | 6.036 | -20.580 | 0.000 | 0.000 | 3.826 | 2.413 | 12.213 | 1.642 | 0.000 | 0.048 | 7.572 | 0.000 | -7.687 | 0.000 | -5.483 | -0.001 |
M N2 APARTMENT | 6.031 | -20.560 | 0.000 | 0.000 | 3.827 | 2.413 | 12.213 | 1.642 | 0.000 | 0.048 | 7.554 | 0.000 | -7.686 | 0.000 | -5.482 | -0.000 |
M S1 APARTMENT | 2.728 | -29.907 | 0.000 | 0.000 | 3.792 | 2.413 | 12.213 | 7.557 | 0.000 | 0.051 | 13.506 | 0.000 | -6.791 | 0.000 | -5.562 | -0.000 |
M S2 APARTMENT | 2.736 | -29.905 | 0.000 | 0.000 | 3.793 | 2.413 | 12.213 | 7.556 | 0.000 | 0.051 | 13.496 | 0.000 | -6.790 | 0.000 | -5.562 | -0.000 |
T SW APARTMENT | 19.036 | -10.612 | 0.000 | 0.000 | 3.859 | 2.413 | 12.213 | 10.748 | 0.000 | 0.094 | 0.000 | 0.000 | -10.713 | 0.000 | -11.106 | -15.933 |
T NW APARTMENT | 22.714 | -7.986 | 0.000 | 0.000 | 3.878 | 2.413 | 12.213 | 4.999 | 0.000 | 0.091 | 0.000 | 0.000 | -11.648 | 0.000 | -11.001 | -15.673 |
T SE APARTMENT | 18.876 | -10.549 | 0.000 | 0.000 | 3.863 | 2.413 | 12.213 | 10.659 | 0.000 | 0.094 | 0.000 | 0.000 | -10.553 | 0.000 | -11.107 | -15.909 |
T NE APARTMENT | 22.551 | -8.039 | 0.000 | 0.000 | 3.888 | 2.413 | 12.213 | 4.862 | 0.000 | 0.091 | 0.000 | 0.000 | -11.425 | 0.000 | -10.995 | -15.559 |
T N1 APARTMENT | 15.090 | -7.275 | 0.000 | 0.000 | 3.880 | 2.413 | 12.213 | 1.657 | 0.000 | 0.068 | 0.000 | 0.000 | -7.340 | 0.000 | -7.010 | -13.695 |
T N2 APARTMENT | 15.096 | -7.278 | 0.000 | 0.000 | 3.881 | 2.413 | 12.213 | 1.656 | 0.000 | 0.068 | 0.000 | 0.000 | -7.338 | 0.000 | -7.010 | -13.700 |
T S1 APARTMENT | 11.707 | -10.036 | 0.000 | 0.000 | 3.852 | 2.413 | 12.213 | 7.548 | 0.000 | 0.071 | 0.000 | 0.000 | -6.494 | 0.000 | -7.116 | -14.158 |
T S2 APARTMENT | 11.709 | -10.041 | 0.000 | 0.000 | 3.852 | 2.413 | 12.213 | 7.546 | 0.000 | 0.071 | 0.000 | 0.000 | -6.493 | 0.000 | -7.116 | -14.153 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.054 | 0.000 | 0.002 | 0.000 | 0.000 | -1.346 | 0.000 | -1.769 | -14.011 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 0.211 | 0.000 | 0.110 | 12.141 | 0.000 | -3.634 | 0.000 | -32.164 | -0.000 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.053 | 0.000 | 0.002 | 0.000 | 0.000 | -1.468 | 0.000 | -1.449 | -14.209 |
Total Facility | 266.877 | -324.237 | 0.000 | 0.000 | 89.322 | 128.627 | 294.692 | 151.768 | 0.000 | 1.565 | 67.778 | 0.000 | -223.995 | 0.000 | -202.355 | -250.045 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 01-SEP-15:30 | 0.00 | -1759.27 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 2702.93 | 0.00 | 45.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1610.12 |
G NW APARTMENT | 29-JUN-17:15 | 0.00 | -1621.21 | 0.00 | 0.00 | 141.82 | 194.45 | 588.62 | 1927.87 | 0.00 | 85.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1317.37 |
OFFICE | 24-JUL-13:30 | 0.00 | -3142.63 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 1848.16 | 0.00 | 49.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -989.64 |
G NE APARTMENT | 29-JUN-19:00 | 0.00 | -1116.81 | 0.00 | 0.00 | 140.88 | 230.46 | 547.42 | 459.04 | 0.00 | 83.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -344.05 |
G N1 APARTMENT | 29-JUN-19:00 | 0.00 | -932.84 | 0.00 | 0.00 | 140.89 | 230.46 | 547.42 | 362.95 | 0.00 | 50.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -398.92 |
G N2 APARTMENT | 29-JUN-19:00 | 0.00 | -920.64 | 0.00 | 0.00 | 140.84 | 230.46 | 547.42 | 363.10 | 0.00 | 49.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -411.16 |
G S1 APARTMENT | 01-SEP-13:30 | 0.00 | -1211.90 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2035.87 | 0.00 | 13.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1289.83 |
G S2 APARTMENT | 06-JAN-12:34 | 0.00 | -1233.57 | 0.00 | 0.00 | 47.42 | 28.81 | 406.15 | 1880.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -147.19 | -982.10 |
M SW APARTMENT | 30-JUN-17:10 | 0.00 | -5157.56 | 0.00 | 0.00 | 141.82 | 194.45 | 588.62 | 1853.43 | 0.00 | 112.37 | 2266.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 30-JUN-18:15 | 0.00 | -4791.89 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 1848.35 | 0.00 | 79.10 | 1944.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 24-JUL-13:30 | 0.00 | -4275.91 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1820.02 | 0.00 | 64.15 | 1939.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 29-JUN-18:45 | 0.00 | -3579.50 | 0.00 | 0.00 | 141.08 | 230.46 | 547.42 | 560.03 | 0.00 | 123.58 | 1976.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 30-JUN-18:45 | 0.00 | -2996.01 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 549.22 | 0.00 | 33.67 | 1493.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 30-JUN-18:45 | 0.00 | -2967.83 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 549.39 | 0.00 | 33.67 | 1465.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 01-SEP-15:15 | 0.00 | -3720.46 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1275.59 | 0.00 | 54.03 | 1770.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 01-SEP-15:15 | 0.00 | -3716.40 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1275.59 | 0.00 | 54.03 | 1766.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 29-JUN-16:05 | 0.00 | -3425.57 | 0.00 | 0.00 | 84.77 | 144.04 | 588.62 | 2045.72 | 0.00 | 237.01 | 325.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 29-JUN-17:15 | 0.00 | -3201.07 | 0.00 | 0.00 | 141.43 | 194.45 | 588.62 | 1877.64 | 0.00 | 161.43 | 237.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 30-JUN-14:15 | 0.00 | -2989.15 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1479.32 | 0.00 | 186.51 | 831.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 29-JUN-16:30 | 0.00 | -2450.51 | 0.00 | 0.00 | 84.27 | 144.04 | 588.62 | 649.36 | 0.00 | 207.79 | 776.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 30-JUN-17:23 | 0.00 | -2102.13 | 0.00 | 0.00 | 141.48 | 194.45 | 588.62 | 343.86 | 0.00 | 83.07 | 750.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 30-JUN-17:23 | 0.00 | -2075.45 | 0.00 | 0.00 | 141.33 | 194.45 | 588.62 | 343.98 | 0.00 | 82.86 | 724.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 30-JUN-14:15 | 0.00 | -2569.29 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 1178.38 | 0.00 | 112.49 | 786.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 01-SEP-13:30 | 0.00 | -2572.55 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1996.45 | 0.00 | 21.89 | 102.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 30-JUN-17:10 | 0.00 | -58627.28 | 0.00 | 0.00 | 3260.21 | 6475.86 | 14071.03 | 17982.19 | 0.00 | 2353.80 | 14484.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 04-JAN-08:15 | 2012.84 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -970.21 | 0.00 | -734.28 | -814.02 |
G NW APARTMENT | 04-JAN-12:00 | 2275.00 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -869.48 | 0.00 | -1107.36 | -786.42 |
OFFICE | 20-NOV-07:01 | 6487.50 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.34 | 0.00 | -204.39 | -6440.34 |
G NE APARTMENT | 04-JAN-12:00 | 2180.52 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -817.77 | 0.00 | -1107.36 | -743.65 |
G N1 APARTMENT | 04-JAN-12:00 | 1383.69 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -528.29 | 0.00 | -667.93 | -675.73 |
G N2 APARTMENT | 04-JAN-12:00 | 1380.21 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -528.35 | 0.00 | -667.93 | -672.19 |
G S1 APARTMENT | 02-DEC-18:13 | 1817.40 | 0.00 | 0.00 | 0.00 | 165.01 | 194.45 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -604.83 | 0.00 | -7.99 | -2152.66 |
G S2 APARTMENT | 06-JAN-12:38 | 1680.09 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 406.15 | 1880.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -148.44 | -3894.50 |
M SW APARTMENT | 04-JAN-06:00 | 4127.38 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1244.73 | 0.00 | -1316.01 | -2103.04 |
M NW APARTMENT | 04-JAN-12:00 | 4875.79 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -901.79 | 0.00 | -1592.01 | -2870.25 |
M SE APARTMENT | 04-JAN-06:00 | 4104.76 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1224.95 | 0.00 | -1316.01 | -2100.20 |
M NE APARTMENT | 04-JAN-12:00 | 4666.35 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -847.85 | 0.00 | -1592.01 | -2714.75 |
M N1 APARTMENT | 12-MAR-06:30 | 2903.47 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -645.47 | 0.00 | 0.00 | -2895.45 |
M N2 APARTMENT | 12-MAR-06:23 | 2901.75 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -645.42 | 0.00 | 0.00 | -2893.78 |
M S1 APARTMENT | 05-MAR-08:30 | 3066.98 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -208.37 | 0.00 | 0.00 | -3364.28 |
M S2 APARTMENT | 15-FEB-01:53 | 3043.46 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -640.14 | 0.00 | 0.00 | -2848.74 |
T SW APARTMENT | 04-JAN-06:00 | 4039.39 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1216.40 | 0.00 | -1742.07 | -1617.33 |
T NW APARTMENT | 04-JAN-06:00 | 4118.24 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1243.51 | 0.00 | -1742.07 | -1669.06 |
T SE APARTMENT | 04-JAN-06:00 | 4026.67 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1195.66 | 0.00 | -1742.07 | -1625.34 |
T NE APARTMENT | 04-JAN-06:00 | 4105.28 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1222.82 | 0.00 | -1742.07 | -1676.79 |
T N1 APARTMENT | 04-JAN-06:00 | 2838.44 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -754.28 | 0.00 | -1050.81 | -1569.75 |
T N2 APARTMENT | 04-JAN-06:00 | 2838.35 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -754.28 | 0.00 | -1050.81 | -1569.66 |
T S1 APARTMENT | 04-JAN-06:00 | 2755.50 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -726.92 | 0.00 | -1050.81 | -1514.17 |
T S2 APARTMENT | 04-JAN-06:00 | 2755.42 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -726.92 | 0.00 | -1050.81 | -1514.09 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 04-JAN-06:00 | 64173.23 | 0.00 | 0.00 | 0.00 | 4362.43 | 4156.84 | 6111.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -24167.40 | 0.00 | -26039.00 | -28597.87 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sec1.1A-General InformationData | |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 33.00 |
Number of hours cooling loads not met | 4.75 |
Number of hours not met | 37.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 736.55 | 133527.51 | 0.00 | 0.00 |
Space Cooling | 74.23 | 23830.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 207.67 | 6585.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 467.85 | 26850.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1465.55 | 736.55 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1465.55 |
Natural Gas | 0.00 | 736.55 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 2202.10 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 23.68 |
Fans-Interior | 66.25 |
Service Water Heating | 149.25 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.56 |
Subtotal | 467.54 |
Natural Gas [MJ/m2] | |
Space Heating | 234.97 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 234.97 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 7.49 |
Space Heating | 33.45 |
Space Cooling | 3.37 |
Fans-Interior | 9.43 |
Service Water Heating | 21.25 |
Receptacle Equipment | 23.22 |
Miscellaneous | 1.79 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.158556 |
G NW APARTMENT DIRECT AIR | 0.146306 |
OFFICE DIRECT AIR | 0.438934 |
G NE APARTMENT DIRECT AIR | 0.102043 |
G N1 APARTMENT DIRECT AIR | 0.087273 |
G N2 APARTMENT DIRECT AIR | 0.086178 |
G S1 APARTMENT DIRECT AIR | 0.104409 |
G S2 APARTMENT DIRECT AIR | 0.107711 |
M SW APARTMENT DIRECT AIR | 0.457908 |
M NW APARTMENT DIRECT AIR | 0.417648 |
M SE APARTMENT DIRECT AIR | 0.411198 |
M NE APARTMENT DIRECT AIR | 0.316052 |
M N1 APARTMENT DIRECT AIR | 0.264274 |
M N2 APARTMENT DIRECT AIR | 0.262342 |
M S1 APARTMENT DIRECT AIR | 0.319245 |
M S2 APARTMENT DIRECT AIR | 0.320546 |
T SW APARTMENT DIRECT AIR | 0.302474 |
T NW APARTMENT DIRECT AIR | 0.269657 |
T SE APARTMENT DIRECT AIR | 0.283148 |
T NE APARTMENT DIRECT AIR | 0.208122 |
T N1 APARTMENT DIRECT AIR | 0.170408 |
T N2 APARTMENT DIRECT AIR | 0.168217 |
T S1 APARTMENT DIRECT AIR | 0.237801 |
T S2 APARTMENT DIRECT AIR | 0.238728 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.158556 |
SPLIT GNW MAIN BRANCH | 0.146306 |
SPLIT OFFICE MAIN BRANCH | 0.438934 |
SPLIT GNE MAIN BRANCH | 0.102043 |
SPLIT GN1 MAIN BRANCH | 0.087273 |
SPLIT GN2 MAIN BRANCH | 0.086178 |
SPLIT GS1 MAIN BRANCH | 0.104409 |
SPLIT GS2 MAIN BRANCH | 0.107711 |
SPLIT MSW MAIN BRANCH | 0.457908 |
SPLIT MNW MAIN BRANCH | 0.417648 |
SPLIT MSE MAIN BRANCH | 0.411198 |
SPLIT MNE MAIN BRANCH | 0.316052 |
SPLIT MN1 MAIN BRANCH | 0.264274 |
SPLIT MN2 MAIN BRANCH | 0.262342 |
SPLIT MS1 MAIN BRANCH | 0.319245 |
SPLIT MS2 MAIN BRANCH | 0.320546 |
SPLIT TSW MAIN BRANCH | 0.302474 |
SPLIT TNW MAIN BRANCH | 0.269657 |
SPLIT TSE MAIN BRANCH | 0.283148 |
SPLIT TNE MAIN BRANCH | 0.208122 |
SPLIT TN1 MAIN BRANCH | 0.170408 |
SPLIT TN2 MAIN BRANCH | 0.168217 |
SPLIT TS1 MAIN BRANCH | 0.237801 |
SPLIT TS2 MAIN BRANCH | 0.238728 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.158556 |
SPLIT GNW | 0.146306 |
SPLIT OFFICE | 0.438934 |
SPLIT GNE | 0.102043 |
SPLIT GN1 | 0.087273 |
SPLIT GN2 | 0.086178 |
SPLIT GS1 | 0.104409 |
SPLIT GS2 | 0.107711 |
SPLIT MSW | 0.457908 |
SPLIT MNW | 0.417648 |
SPLIT MSE | 0.411198 |
SPLIT MNE | 0.316052 |
SPLIT MN1 | 0.264274 |
SPLIT MN2 | 0.262342 |
SPLIT MS1 | 0.319245 |
SPLIT MS2 | 0.320546 |
SPLIT TSW | 0.302474 |
SPLIT TNW | 0.269657 |
SPLIT TSE | 0.283148 |
SPLIT TNE | 0.208122 |
SPLIT TN1 | 0.170408 |
SPLIT TN2 | 0.168217 |
SPLIT TS1 | 0.237801 |
SPLIT TS2 | 0.238728 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.158556 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.146306 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.438934 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.102043 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.087273 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.086178 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.104409 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.107711 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.457908 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.417648 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.411198 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.316052 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.264274 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.262342 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.319245 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.320546 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.302474 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.269657 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.283148 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.208122 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.170408 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.168217 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.237801 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.238728 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.158556 | 2852.73 | 0.769261 |
SPLIT GNW COOLING COIL | 0.146306 | 2631.97 | 0.769307 |
SPLIT OFFICE COOLING COIL | 0.438934 | 7265.92 | 0.798655 |
SPLIT GNE COOLING COIL | 0.102043 | 1938.11 | 0.751433 |
SPLIT GN1 COOLING COIL | 0.087273 | 1680.49 | 0.747065 |
SPLIT GN2 COOLING COIL | 0.086178 | 1663.67 | 0.746254 |
SPLIT GS1 COOLING COIL | 0.104409 | 2089.71 | 0.735078 |
SPLIT GS2 COOLING COIL | 0.107711 | 2134.84 | 0.738061 |
SPLIT MSW COOLING COIL | 0.457908 | 7862.37 | 0.785451 |
SPLIT MNW COOLING COIL | 0.417648 | 7204.60 | 0.783803 |
SPLIT MSE COOLING COIL | 0.411198 | 7391.42 | 0.769575 |
SPLIT MNE COOLING COIL | 0.316052 | 5629.85 | 0.772659 |
SPLIT MN1 COOLING COIL | 0.264274 | 4746.07 | 0.769885 |
SPLIT MN2 COOLING COIL | 0.262342 | 4717.02 | 0.769478 |
SPLIT MS1 COOLING COIL | 0.319245 | 5921.50 | 0.759113 |
SPLIT MS2 COOLING COIL | 0.320546 | 5928.24 | 0.760077 |
SPLIT TSW COOLING COIL | 0.302474 | 5190.96 | 0.785628 |
SPLIT TNW COOLING COIL | 0.269657 | 4580.55 | 0.789283 |
SPLIT TSE COOLING COIL | 0.283148 | 4923.47 | 0.781005 |
SPLIT TNE COOLING COIL | 0.208122 | 3789.52 | 0.765245 |
SPLIT TN1 COOLING COIL | 0.170408 | 3001.73 | 0.776501 |
SPLIT TN2 COOLING COIL | 0.168217 | 2968.82 | 0.775840 |
SPLIT TS1 COOLING COIL | 0.237801 | 4174.64 | 0.777678 |
SPLIT TS2 COOLING COIL | 0.238728 | 4188.61 | 0.777869 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.158556 | 0.158556 | 0.158556 | 0.158556 | 4027.69 | 2852.73 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.146306 | 0.146306 | 0.146306 | 0.146306 | 3954.03 | 2631.97 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.438934 | 0.438934 | 0.438934 | 0.438934 | 7039.97 | 7265.92 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.102043 | 0.102043 | 0.102043 | 0.102043 | 3942.11 | 1938.11 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.087273 | 0.087273 | 0.087273 | 0.087273 | 3126.02 | 1680.49 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.086178 | 0.086178 | 0.086178 | 0.086178 | 3125.76 | 1663.67 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.104409 | 0.104409 | 0.104409 | 0.104409 | 3143.66 | 2089.71 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.107711 | 0.107711 | 0.107711 | 0.107711 | 3280.44 | 2134.84 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.457908 | 0.457908 | 0.457908 | 0.457908 | 7524.13 | 7862.37 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.417648 | 0.417648 | 0.417648 | 0.417648 | 7481.90 | 7204.60 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.411198 | 0.411198 | 0.411198 | 0.411198 | 7492.93 | 7391.42 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.316052 | 0.316052 | 0.316052 | 0.316052 | 7450.66 | 5629.85 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.264274 | 0.264274 | 0.264274 | 0.264274 | 5459.39 | 4746.07 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.262342 | 0.262342 | 0.262342 | 0.262342 | 5458.65 | 4717.02 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.319245 | 0.319245 | 0.319245 | 0.319245 | 5504.87 | 5921.50 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.320546 | 0.320546 | 0.320546 | 0.320546 | 5504.14 | 5928.24 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.302474 | 0.302474 | 0.302474 | 0.302474 | 5731.77 | 5190.96 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.269657 | 0.269657 | 0.269657 | 0.269657 | 5711.44 | 4580.55 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.283148 | 0.283148 | 0.283148 | 0.283148 | 5715.06 | 4923.47 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.208122 | 0.208122 | 0.208122 | 0.208122 | 5694.71 | 3789.52 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.170408 | 0.170408 | 0.170408 | 0.170408 | 4647.24 | 3001.73 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.168217 | 0.168217 | 0.168217 | 0.168217 | 4646.83 | 2968.82 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.237801 | 0.237801 | 0.237801 | 0.237801 | 4666.35 | 4174.64 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.238728 | 0.238728 | 0.238728 | 0.238728 | 4665.94 | 4188.61 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.158556 |
SPLIT GNW SUPPLY FAN | 0.146306 |
SPLIT OFFICE SUPPLY FAN | 0.438934 |
SPLIT GNE SUPPLY FAN | 0.102043 |
SPLIT GN1 SUPPLY FAN | 0.087273 |
SPLIT GN2 SUPPLY FAN | 0.086178 |
SPLIT GS1 SUPPLY FAN | 0.104409 |
SPLIT GS2 SUPPLY FAN | 0.107711 |
SPLIT MSW SUPPLY FAN | 0.457908 |
SPLIT MNW SUPPLY FAN | 0.417648 |
SPLIT MSE SUPPLY FAN | 0.411198 |
SPLIT MNE SUPPLY FAN | 0.316052 |
SPLIT MN1 SUPPLY FAN | 0.264274 |
SPLIT MN2 SUPPLY FAN | 0.262342 |
SPLIT MS1 SUPPLY FAN | 0.319245 |
SPLIT MS2 SUPPLY FAN | 0.320546 |
SPLIT TSW SUPPLY FAN | 0.302474 |
SPLIT TNW SUPPLY FAN | 0.269657 |
SPLIT TSE SUPPLY FAN | 0.283148 |
SPLIT TNE SUPPLY FAN | 0.208122 |
SPLIT TN1 SUPPLY FAN | 0.170408 |
SPLIT TN2 SUPPLY FAN | 0.168217 |
SPLIT TS1 SUPPLY FAN | 0.237801 |
SPLIT TS2 SUPPLY FAN | 0.238728 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 4027.69 |
SPLIT GNW HEATING COIL | 3954.03 |
SPLIT OFFICE HEATING COIL | 7039.97 |
SPLIT GNE HEATING COIL | 3942.11 |
SPLIT GN1 HEATING COIL | 3126.02 |
SPLIT GN2 HEATING COIL | 3125.76 |
SPLIT GS1 HEATING COIL | 3143.66 |
SPLIT GS2 HEATING COIL | 3280.44 |
SPLIT MSW HEATING COIL | 7524.13 |
SPLIT MNW HEATING COIL | 7481.90 |
SPLIT MSE HEATING COIL | 7492.93 |
SPLIT MNE HEATING COIL | 7450.66 |
SPLIT MN1 HEATING COIL | 5459.39 |
SPLIT MN2 HEATING COIL | 5458.65 |
SPLIT MS1 HEATING COIL | 5504.87 |
SPLIT MS2 HEATING COIL | 5504.14 |
SPLIT TSW HEATING COIL | 5731.77 |
SPLIT TNW HEATING COIL | 5711.44 |
SPLIT TSE HEATING COIL | 5715.06 |
SPLIT TNE HEATING COIL | 5694.71 |
SPLIT TN1 HEATING COIL | 4647.24 |
SPLIT TN2 HEATING COIL | 4646.83 |
SPLIT TS1 HEATING COIL | 4666.35 |
SPLIT TS2 HEATING COIL | 4665.94 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.71 | -11.6 |
March | 21.75 | -6.2 |
April | 22.07 | 3.97 |
May | 23.04 | 13.43 |
June | 24.10 | 18.03 |
July | 24.34 | 19.67 |
August | 24.29 | 17.94 |
September | 23.74 | 12.29 |
October | 22.10 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.69 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.86 | 3.97 |
May | 22.86 | 13.43 |
June | 24.09 | 18.03 |
July | 24.33 | 19.67 |
August | 24.25 | 17.94 |
September | 23.53 | 12.29 |
October | 21.86 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.61 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.68 | -16.9 |
February | 18.30 | -11.6 |
March | 19.52 | -6.2 |
April | 21.52 | 3.97 |
May | 23.26 | 13.43 |
June | 23.86 | 18.03 |
July | 23.90 | 19.67 |
August | 23.89 | 17.94 |
September | 23.73 | 12.29 |
October | 22.03 | 5.42 |
November | 19.91 | -2.0 |
December | 17.72 | -14.6 |
Annual Sum or Average | 21.29 | 3.36 |
Minimum of Months | 17.68 | -16.9 |
Maximum of Months | 23.90 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.81 | 3.97 |
May | 22.76 | 13.43 |
June | 24.07 | 18.03 |
July | 24.31 | 19.67 |
August | 24.21 | 17.94 |
September | 23.44 | 12.29 |
October | 21.82 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.58 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.78 | 3.97 |
May | 22.65 | 13.43 |
June | 24.05 | 18.03 |
July | 24.31 | 19.67 |
August | 24.24 | 17.94 |
September | 23.56 | 12.29 |
October | 21.83 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.58 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.78 | 3.97 |
May | 22.64 | 13.43 |
June | 24.05 | 18.03 |
July | 24.31 | 19.67 |
August | 24.23 | 17.94 |
September | 23.56 | 12.29 |
October | 21.83 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.58 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.71 | -11.6 |
March | 21.73 | -6.2 |
April | 22.00 | 3.97 |
May | 22.91 | 13.43 |
June | 24.10 | 18.03 |
July | 24.33 | 19.67 |
August | 24.30 | 17.94 |
September | 23.85 | 12.29 |
October | 22.13 | 5.42 |
November | 21.73 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.69 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.71 | -11.6 |
March | 21.73 | -6.2 |
April | 22.00 | 3.97 |
May | 22.91 | 13.43 |
June | 24.10 | 18.03 |
July | 24.33 | 19.67 |
August | 24.29 | 17.94 |
September | 23.85 | 12.29 |
October | 22.14 | 5.42 |
November | 21.73 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.69 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.80 | -11.6 |
March | 22.00 | -6.2 |
April | 22.95 | 3.97 |
May | 24.26 | 13.43 |
June | 24.39 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.29 | 12.29 |
October | 23.02 | 5.42 |
November | 21.83 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.07 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.75 | -6.2 |
April | 22.50 | 3.97 |
May | 24.18 | 13.43 |
June | 24.39 | 18.03 |
July | 24.40 | 19.67 |
August | 24.39 | 17.94 |
September | 24.19 | 12.29 |
October | 22.59 | 5.42 |
November | 21.73 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.94 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.78 | -11.6 |
March | 21.97 | -6.2 |
April | 22.97 | 3.97 |
May | 24.26 | 13.43 |
June | 24.39 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.27 | 12.29 |
October | 22.96 | 5.42 |
November | 21.81 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.06 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.72 | -6.2 |
April | 22.45 | 3.97 |
May | 24.15 | 13.43 |
June | 24.39 | 18.03 |
July | 24.40 | 19.67 |
August | 24.39 | 17.94 |
September | 24.13 | 12.29 |
October | 22.44 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.91 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.73 | -6.2 |
April | 22.48 | 3.97 |
May | 24.19 | 13.43 |
June | 24.40 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.27 | 12.29 |
October | 22.73 | 5.42 |
November | 21.75 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.96 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.73 | -6.2 |
April | 22.47 | 3.97 |
May | 24.19 | 13.43 |
June | 24.40 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.27 | 12.29 |
October | 22.71 | 5.42 |
November | 21.75 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.96 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.85 | -11.6 |
March | 22.08 | -6.2 |
April | 23.13 | 3.97 |
May | 24.30 | 13.43 |
June | 24.40 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.35 | 12.29 |
October | 23.28 | 5.42 |
November | 21.95 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.14 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.85 | -11.6 |
March | 22.08 | -6.2 |
April | 23.13 | 3.97 |
May | 24.30 | 13.43 |
June | 24.40 | 18.03 |
July | 24.40 | 19.67 |
August | 24.40 | 17.94 |
September | 24.35 | 12.29 |
October | 23.28 | 5.42 |
November | 21.95 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.14 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.40 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.78 | -11.6 |
March | 21.94 | -6.2 |
April | 22.52 | 3.97 |
May | 23.78 | 13.43 |
June | 24.24 | 18.03 |
July | 24.36 | 19.67 |
August | 24.31 | 17.94 |
September | 23.58 | 12.29 |
October | 22.33 | 5.42 |
November | 21.78 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.84 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.75 | -6.2 |
April | 22.25 | 3.97 |
May | 23.67 | 13.43 |
June | 24.22 | 18.03 |
July | 24.35 | 19.67 |
August | 24.28 | 17.94 |
September | 23.34 | 12.29 |
October | 22.04 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.73 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.76 | -11.6 |
March | 21.93 | -6.2 |
April | 22.54 | 3.97 |
May | 23.79 | 13.43 |
June | 24.24 | 18.03 |
July | 24.35 | 19.67 |
August | 24.30 | 17.94 |
September | 23.57 | 12.29 |
October | 22.30 | 5.42 |
November | 21.77 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.84 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.21 | 3.97 |
May | 23.65 | 13.43 |
June | 24.19 | 18.03 |
July | 24.32 | 19.67 |
August | 24.24 | 17.94 |
September | 23.28 | 12.29 |
October | 21.98 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.71 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.32 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.72 | -6.2 |
April | 22.18 | 3.97 |
May | 23.67 | 13.43 |
June | 24.23 | 18.03 |
July | 24.34 | 19.67 |
August | 24.29 | 17.94 |
September | 23.35 | 12.29 |
October | 22.00 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.17 | 3.97 |
May | 23.66 | 13.43 |
June | 24.23 | 18.03 |
July | 24.34 | 19.67 |
August | 24.28 | 17.94 |
September | 23.34 | 12.29 |
October | 22.00 | 5.42 |
November | 21.72 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.80 | -11.6 |
March | 21.95 | -6.2 |
April | 22.57 | 3.97 |
May | 23.85 | 13.43 |
June | 24.28 | 18.03 |
July | 24.37 | 19.67 |
August | 24.34 | 17.94 |
September | 23.70 | 12.29 |
October | 22.41 | 5.42 |
November | 21.80 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.88 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.80 | -11.6 |
March | 21.96 | -6.2 |
April | 22.58 | 3.97 |
May | 23.85 | 13.43 |
June | 24.28 | 18.03 |
July | 24.37 | 19.67 |
August | 24.34 | 17.94 |
September | 23.70 | 12.29 |
October | 22.41 | 5.42 |
November | 21.80 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.88 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.77 | -16.9 |
February | 20.41 | -11.6 |
March | 21.22 | -6.2 |
April | 22.86 | 3.97 |
May | 25.35 | 13.43 |
June | 26.29 | 18.03 |
July | 26.59 | 19.67 |
August | 26.28 | 17.94 |
September | 24.84 | 12.29 |
October | 22.64 | 5.42 |
November | 21.19 | -2.0 |
December | 19.90 | -14.6 |
Annual Sum or Average | 23.13 | 3.36 |
Minimum of Months | 19.77 | -16.9 |
Maximum of Months | 26.59 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.23 | -16.9 |
February | 18.12 | -11.6 |
March | 19.00 | -6.2 |
April | 20.85 | 3.97 |
May | 23.00 | 13.43 |
June | 25.11 | 18.03 |
July | 25.75 | 19.67 |
August | 25.39 | 17.94 |
September | 24.21 | 12.29 |
October | 21.33 | 5.42 |
November | 19.65 | -2.0 |
December | 17.56 | -14.6 |
Annual Sum or Average | 21.45 | 3.36 |
Minimum of Months | 17.23 | -16.9 |
Maximum of Months | 25.75 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.51 | -16.9 |
February | 22.89 | -11.6 |
March | 23.35 | -6.2 |
April | 24.66 | 3.97 |
May | 26.50 | 13.43 |
June | 26.86 | 18.03 |
July | 26.97 | 19.67 |
August | 26.83 | 17.94 |
September | 26.44 | 12.29 |
October | 24.78 | 5.42 |
November | 23.20 | -2.0 |
December | 22.50 | -14.6 |
Annual Sum or Average | 24.80 | 3.36 |
Minimum of Months | 22.50 | -16.9 |
Maximum of Months | 26.97 | 19.67 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.122394E+12 | 76727.272 | 30-JAN-18:30 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32604.443 | 0.000 | 0.000 | 0.000 |
February | 0.111012E+12 | 76756.338 | 22-FEB-18:15 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32633.508 | 0.000 | 0.000 | 0.000 |
March | 0.122355E+12 | 74361.259 | 10-MAR-18:15 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30238.430 | 0.000 | 0.000 | 0.000 |
April | 0.117992E+12 | 80407.923 | 23-APR-17:00 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 11346.161 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27447.263 | 0.000 | 0.000 | 0.000 |
May | 0.126929E+12 | 86198.550 | 25-MAY-17:15 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 16497.521 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28086.530 | 0.000 | 0.000 | 0.000 |
June | 0.128884E+12 | 92295.013 | 29-JUN-17:30 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 23830.286 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26850.228 | 0.000 | 0.000 | 0.000 |
July | 0.136455E+12 | 88453.870 | 23-JUL-17:00 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 18838.035 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28001.336 | 0.000 | 0.000 | 0.000 |
August | 0.130396E+12 | 86151.183 | 08-AUG-17:30 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 19898.595 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24638.088 | 0.000 | 0.000 | 0.000 |
September | 0.116617E+12 | 80401.509 | 01-SEP-17:15 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 14643.259 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24143.751 | 0.000 | 0.000 | 0.000 |
October | 0.117228E+12 | 74458.589 | 22-OCT-17:30 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 4625.447 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25710.313 | 0.000 | 0.000 | 0.000 |
November | 0.114571E+12 | 72485.852 | 01-NOV-17:45 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28363.023 | 0.000 | 0.000 | 0.000 |
December | 0.120719E+12 | 75422.790 | 22-DEC-18:45 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 31299.961 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.146555E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.111012E+12 | 72485.852 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24143.751 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.136455E+12 | 92295.013 | 8572.775 | 26456.413 | 6585.311 | 0.000 | 23830.286 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32633.508 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.191158E+12 | 133527.510 | 04-JAN-05:00 | 133527.510 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 133527.510 |
February | 0.132026E+12 | 116677.276 | 14-FEB-04:00 | 116677.276 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 116677.276 |
March | 0.943608E+11 | 100106.050 | 05-MAR-03:00 | 100106.050 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 100106.050 |
April | 0.313906E+11 | 56785.019 | 05-APR-02:00 | 56785.019 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 56785.019 |
May | 0.233321E+10 | 19050.587 | 01-MAY-03:00 | 19050.587 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19050.587 |
June | 0.138979E+08 | 1362.354 | 04-JUN-03:00 | 1362.354 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1362.354 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 4049511.300 | 844.125 | 19-AUG-05:30 | 844.125 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 844.125 |
September | 0.718084E+09 | 4576.159 | 28-SEP-01:00 | 4576.159 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4576.159 |
October | 0.222759E+11 | 50222.593 | 30-OCT-06:00 | 50222.593 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 50222.593 |
November | 0.810623E+11 | 86906.201 | 25-NOV-04:00 | 86906.201 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 86906.201 |
December | 0.181204E+12 | 129961.276 | 24-DEC-07:00 | 129961.276 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 129961.276 |
Annual Sum or Average | 0.736548E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.191158E+12 | 133527.510 | 133527.510 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 133527.510 |