Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Simulation Timestamp: 2018-10-19 09:20:29
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1594.69 | 508.74 | 564.70 |
Net Site Energy | 1594.69 | 508.74 | 564.70 |
Total Source Energy | 5032.80 | 1605.56 | 1782.17 |
Net Source Energy | 5032.80 | 1605.56 | 1782.17 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 8.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 275.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 273.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 321.92 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1586.25 | 8.45 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 8.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 275.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 273.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 321.92 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 308.22 | 2.99 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 561.71 | 2.99 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 277.67 | 2.69 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 506.04 | 2.69 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1586.25 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1586.25 | 100.00 |
Total On-Site and Utility Electric Sources | 1586.25 | 100.00 |
Total Electricity End Uses | 1586.25 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 5.50 |
Time Setpoint Not Met During Occupied Cooling | 11.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 257.25 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Latitude [deg] | 32.17 |
Longitude [deg] | -110.9 |
Elevation [m] | 809.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-JUN-17:30 | 07-DEC-04:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 22397.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 28729.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 8659.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 18074.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 90492.25 | 22397.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 22397.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 28729.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 8659.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 18074.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 9.16 | 0.00 | 0.00 | 0.00 |
Cooling | 872.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 864.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1019.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 5023.65 | 9.16 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 3.24 | 0.00 | 0.00 | 0.00 |
Cooling | 308.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 306.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 361.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1778.93 | 3.24 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 3.24 | 0.00 | 0.00 | 0.00 |
Cooling | 308.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 306.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 361.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1778.93 | 3.24 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50 | 0.00 | 0.50 | Wetbulb [C] | 2.10 | 140.00 |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80 | 13.30 | 18.50 | Wetbulb [C] | 4.80 | 310.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.55 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 4.600 | 0.293 | 0.130 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 4.600 | 0.293 | 0.130 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 4.600 | 0.293 | 0.130 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 4.600 | 0.293 | 0.130 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 4.600 | 0.293 | 0.130 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.72_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 4.600 | 0.293 | 0.130 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.72_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 4.600 | 0.293 | 0.130 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.72_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 4.600 | 0.293 | 0.130 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 4.600 | 0.293 | 0.130 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 4.600 | 0.293 | 0.130 | ||||||||||||
North Total or Average | 112.97 | 4.600 | 0.293 | 0.130 | ||||||||||||
Non-North Total or Average | 193.95 | 4.600 | 0.293 | 0.130 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.74 | 83.74 | 39.43 | |
Exterior Lighting Total | 2508.33 | 39.43 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4056.05 | 3225.69 | 830.37 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4026.93 | 3216.13 | 810.80 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8645.68 | 6904.92 | 1740.76 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3236.96 | 2585.22 | 651.74 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2454.13 | 1960.01 | 494.13 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2442.10 | 1950.40 | 491.70 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2616.46 | 2009.66 | 606.80 | 0.77 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2662.27 | 2046.46 | 615.81 | 0.77 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9571.43 | 7644.27 | 1927.16 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9550.45 | 7627.51 | 1922.93 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8325.66 | 6649.33 | 1676.33 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7897.57 | 6307.44 | 1590.13 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5928.05 | 4734.47 | 1193.58 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5909.22 | 4719.43 | 1189.79 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6321.49 | 4904.10 | 1417.39 | 0.78 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6336.70 | 4916.33 | 1420.37 | 0.78 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6185.05 | 4939.73 | 1245.33 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6068.31 | 4846.49 | 1221.82 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5583.73 | 4414.60 | 1169.13 | 0.79 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5118.57 | 4040.59 | 1077.98 | 0.79 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3984.44 | 3182.20 | 802.25 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3962.40 | 3164.59 | 797.81 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4470.70 | 3505.11 | 965.60 | 0.78 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4479.25 | 3511.96 | 967.28 | 0.78 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3865.8 | 3.13 | 10.69 | 11.11 | 10.41 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3836.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8236.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3083.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2337.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2326.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2502.8 | 3.18 | 10.85 | 11.29 | 10.64 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2546.4 | 3.18 | 10.85 | 11.28 | 10.64 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9118.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9098.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7931.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7523.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5647.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5629.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6040.6 | 3.17 | 10.81 | 11.24 | 10.57 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6055.1 | 3.17 | 10.81 | 11.24 | 10.57 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5892.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5781.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5325.1 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4882.3 | 3.14 | 10.73 | 11.15 | 10.46 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3795.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3774.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4267.4 | 3.15 | 10.76 | 11.18 | 10.50 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4275.5 | 3.15 | 10.76 | 11.18 | 10.50 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1597.54 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1563.28 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 3186.88 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1571.49 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1411.22 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1411.22 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1411.22 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1411.22 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 2944.04 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 2913.99 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 2965.14 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 2935.09 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2822.44 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2822.44 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2822.44 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2822.44 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 2327.97 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 2312.80 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 2339.37 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 2324.21 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 1757.84 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 1758.04 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 1772.94 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 1773.14 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 271.93 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 272.48 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.52 | 585.02 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 219.03 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 166.06 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 165.25 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 162.32 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 165.46 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 647.66 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 646.24 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.50 | 563.36 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.48 | 534.39 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 401.13 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 399.85 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 401.14 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 402.18 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 418.52 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 410.62 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 369.57 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 337.63 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 269.61 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 268.12 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 290.47 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 291.05 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2345.52 | 2814.63 | 0.202 | 0.243 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.94 | 0.00558 |
G NW APARTMENT | 2350.25 | 2820.30 | 0.203 | 0.243 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 37.94 | 0.00558 |
OFFICE | 4803.42 | 5764.10 | 0.435 | 0.522 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 34.62 | 0.00558 |
G NE APARTMENT | 1889.22 | 2267.06 | 0.163 | 0.196 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
G N1 APARTMENT | 1432.30 | 1718.76 | 0.124 | 0.148 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 36.61 | 0.00558 |
G N2 APARTMENT | 1425.28 | 1710.33 | 0.123 | 0.148 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 36.61 | 0.00558 |
G S1 APARTMENT | 1400.07 | 1680.09 | 0.121 | 0.145 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
G S2 APARTMENT | 1427.15 | 1712.58 | 0.123 | 0.148 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
M SW APARTMENT | 5586.32 | 6703.58 | 0.482 | 0.578 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.94 | 0.00558 |
M NW APARTMENT | 5574.00 | 6688.79 | 0.481 | 0.577 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 37.94 | 0.00558 |
M SE APARTMENT | 4859.24 | 5831.09 | 0.419 | 0.503 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
M NE APARTMENT | 4609.38 | 5531.26 | 0.398 | 0.477 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
M N1 APARTMENT | 3459.80 | 4151.76 | 0.298 | 0.358 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
M N2 APARTMENT | 3448.80 | 4138.56 | 0.297 | 0.357 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
M S1 APARTMENT | 3459.93 | 4151.91 | 0.298 | 0.358 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
M S2 APARTMENT | 3468.93 | 4162.71 | 0.299 | 0.359 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
T SW APARTMENT | 3609.93 | 4331.91 | 0.311 | 0.374 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47 | 0.00558 |
T NW APARTMENT | 3541.76 | 4250.11 | 0.305 | 0.367 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
T SE APARTMENT | 3187.73 | 3825.27 | 0.275 | 0.330 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
T NE APARTMENT | 2912.25 | 3494.70 | 0.251 | 0.301 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 40.80 | 0.00558 |
T N1 APARTMENT | 2325.46 | 2790.55 | 0.201 | 0.241 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 37.61 | 0.00558 |
T N2 APARTMENT | 2312.59 | 2775.11 | 0.199 | 0.239 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 37.61 | 0.00558 |
T S1 APARTMENT | 2505.40 | 3006.48 | 0.216 | 0.259 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 40.80 | 0.00558 |
T S2 APARTMENT | 2510.44 | 3012.53 | 0.217 | 0.260 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 40.80 | 0.00558 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 821.22 | 985.47 | 0.026 | 0.031 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
G NW APARTMENT | 810.87 | 973.05 | 0.026 | 0.031 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
OFFICE | 1994.07 | 2392.89 | 0.061 | 0.073 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50 | 0.00432 |
G NE APARTMENT | 817.82 | 981.38 | 0.026 | 0.031 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
G N1 APARTMENT | 426.24 | 511.48 | 0.014 | 0.026 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
G N2 APARTMENT | 426.33 | 511.60 | 0.014 | 0.026 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
G S1 APARTMENT | 438.69 | 526.43 | 0.014 | 0.026 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
G S2 APARTMENT | 509.12 | 610.95 | 0.016 | 0.026 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M SW APARTMENT | 1467.42 | 1760.90 | 0.047 | 0.056 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M NW APARTMENT | 1442.01 | 1730.41 | 0.046 | 0.055 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M SE APARTMENT | 1485.26 | 1782.31 | 0.047 | 0.056 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M NE APARTMENT | 1459.85 | 1751.82 | 0.046 | 0.056 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M N1 APARTMENT | 495.27 | 594.33 | 0.016 | 0.052 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M N2 APARTMENT | 495.62 | 594.74 | 0.016 | 0.052 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M S1 APARTMENT | 526.26 | 631.51 | 0.017 | 0.052 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
M S2 APARTMENT | 526.60 | 631.92 | 0.017 | 0.052 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T SW APARTMENT | 1457.55 | 1749.06 | 0.046 | 0.055 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T NW APARTMENT | 1444.72 | 1733.66 | 0.046 | 0.055 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T SE APARTMENT | 1467.19 | 1760.62 | 0.047 | 0.056 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T NE APARTMENT | 1454.37 | 1745.24 | 0.046 | 0.055 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T N1 APARTMENT | 975.41 | 1170.49 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T N2 APARTMENT | 975.58 | 1170.70 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T S1 APARTMENT | 988.18 | 1185.81 | 0.031 | 0.038 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
T S2 APARTMENT | 988.35 | 1186.02 | 0.031 | 0.038 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 0.50 | 0.00432 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.24 | 0.24 | 0.03 | 0.03 |
SPLIT GNW | 0.24 | 0.24 | 0.03 | 0.03 |
SPLIT OFFICE | 0.52 | 0.52 | 0.07 | 0.07 |
SPLIT GNE | 0.20 | 0.20 | 0.03 | 0.03 |
SPLIT GN1 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT GN2 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT GS1 | 0.14 | 0.14 | 0.03 | 0.03 |
SPLIT GS2 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT MSW | 0.58 | 0.58 | 0.06 | 0.06 |
SPLIT MNW | 0.58 | 0.58 | 0.05 | 0.05 |
SPLIT MSE | 0.50 | 0.50 | 0.06 | 0.06 |
SPLIT MNE | 0.48 | 0.48 | 0.06 | 0.06 |
SPLIT MN1 | 0.36 | 0.36 | 0.05 | 0.05 |
SPLIT MN2 | 0.36 | 0.36 | 0.05 | 0.05 |
SPLIT MS1 | 0.36 | 0.36 | 0.05 | 0.05 |
SPLIT MS2 | 0.36 | 0.36 | 0.05 | 0.05 |
SPLIT TSW | 0.37 | 0.37 | 0.06 | 0.06 |
SPLIT TNW | 0.37 | 0.37 | 0.05 | 0.05 |
SPLIT TSE | 0.33 | 0.33 | 0.06 | 0.06 |
SPLIT TNE | 0.30 | 0.30 | 0.06 | 0.06 |
SPLIT TN1 | 0.24 | 0.24 | 0.04 | 0.04 |
SPLIT TN2 | 0.24 | 0.24 | 0.04 | 0.04 |
SPLIT TS1 | 0.26 | 0.26 | 0.04 | 0.04 |
SPLIT TS2 | 0.26 | 0.26 | 0.04 | 0.04 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2107.75 | 5085.75 | 129.75 |
G NW APARTMENT | 2078.25 | 5548.00 | 176.25 |
OFFICE | 579.50 | 1282.75 | 0.00 |
G NE APARTMENT | 2059.50 | 5588.00 | 175.00 |
G N1 APARTMENT | 1920.75 | 5787.25 | 165.50 |
G N2 APARTMENT | 1921.75 | 5786.50 | 165.25 |
G S1 APARTMENT | 1958.00 | 5491.50 | 126.50 |
G S2 APARTMENT | 2005.25 | 5423.00 | 115.25 |
M SW APARTMENT | 2870.75 | 1202.50 | 55.50 |
M NW APARTMENT | 2471.00 | 2439.50 | 61.75 |
M SE APARTMENT | 2920.25 | 1227.75 | 62.00 |
M NE APARTMENT | 2513.75 | 2518.25 | 70.50 |
M N1 APARTMENT | 2391.50 | 2292.50 | 72.00 |
M N2 APARTMENT | 2391.50 | 2297.75 | 72.25 |
M S1 APARTMENT | 2714.25 | 757.25 | 43.00 |
M S2 APARTMENT | 2715.25 | 760.75 | 43.00 |
T SW APARTMENT | 3471.50 | 2792.00 | 113.75 |
T NW APARTMENT | 3006.50 | 3576.25 | 170.25 |
T SE APARTMENT | 3430.50 | 2722.75 | 118.00 |
T NE APARTMENT | 2987.75 | 3627.00 | 178.00 |
T N1 APARTMENT | 2612.00 | 3694.50 | 149.75 |
T N2 APARTMENT | 2614.50 | 3692.75 | 151.25 |
T S1 APARTMENT | 3018.25 | 2629.25 | 90.75 |
T S2 APARTMENT | 3021.75 | 2627.50 | 90.50 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 4122.50 | 5814.25 | 257.25 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
G NW APARTMENT | 0.00 | 5.75 | 0.00 | 5.75 |
OFFICE | 0.00 | 24.50 | 0.00 | 0.00 |
G NE APARTMENT | 0.25 | 0.50 | 0.25 | 0.50 |
G N1 APARTMENT | 3.00 | 8.25 | 3.00 | 8.25 |
G N2 APARTMENT | 2.25 | 7.75 | 2.25 | 7.75 |
G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 0.00 | 2.25 | 0.00 | 2.25 |
M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 0.00 | 6.25 | 0.00 | 6.25 |
M N2 APARTMENT | 0.00 | 6.25 | 0.00 | 6.25 |
M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 0.00 | 1.75 | 0.00 | 1.75 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 0.00 | 5.00 | 0.00 | 5.00 |
T N2 APARTMENT | 0.00 | 5.25 | 0.00 | 5.25 |
T S1 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 5.50 | 36.00 | 5.50 | 11.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.368 | 0.079 | 0.000 | 0.081 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.079 | 0.000 | 0.075 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.520 | 0.081 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.079 | 0.000 | 0.075 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.048 | 0.000 | 0.074 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.048 | 0.000 | 0.074 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.048 | 0.000 | 0.081 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.048 | 0.000 | 0.081 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.114 | 0.000 | 0.097 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.114 | 0.000 | 0.091 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.114 | 0.000 | 0.097 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.114 | 0.000 | 0.091 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.069 | 0.000 | 0.091 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.069 | 0.000 | 0.091 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.069 | 0.000 | 0.097 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.069 | 0.000 | 0.097 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.151 | 0.000 | 0.114 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.151 | 0.000 | 0.106 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.151 | 0.000 | 0.114 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.151 | 0.000 | 0.106 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.091 | 0.000 | 0.105 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.091 | 0.000 | 0.105 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.091 | 0.000 | 0.114 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.091 | 0.000 | 0.114 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.509 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.394 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.388 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.393 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.387 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.390 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.390 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.396 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.396 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 321.92 | 0.00 | 01-JAN-00:15 | 32014.34 | 01-JAN-07:15 |
WaterSystems:Electricity | 321.92 | 0.00 | 01-JAN-00:15 | 32014.34 | 01-JAN-07:15 |
Water Heater:WaterSystems:Electricity | 321.92 | 0.00 | 01-JAN-00:15 | 32014.34 | 01-JAN-07:15 |
Fans:Electricity | 273.07 | 8659.09 | 01-JAN-00:15 | 8659.09 | 01-JAN-07:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
ElectricityPurchased:Plant | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
Cogeneration:ElectricityPurchased | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
ElectricityNet:Plant | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
Cogeneration:ElectricityNet | 1586.25 | 22029.39 | 01-JAN-03:15 | 90492.25 | 29-JUN-17:30 |
ExteriorLights:Electricity | 39.43 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.43 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 548.47 | 8659.09 | 01-JAN-00:15 | 39062.79 | 28-JUN-15:30 |
General:Fans:Electricity | 273.07 | 8659.09 | 01-JAN-00:15 | 8659.09 | 01-JAN-07:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 275.40 | 0.00 | 01-JAN-00:15 | 30403.70 | 28-JUN-15:30 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 8.45 | 0.00 | 01-JAN-11:45 | 22397.96 | 07-DEC-05:00 |
Gas:HVAC | 8.45 | 0.00 | 01-JAN-11:45 | 22397.96 | 07-DEC-05:00 |
Heating:Gas | 8.45 | 0.00 | 01-JAN-11:45 | 22397.96 | 07-DEC-05:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1852.04 | 2474.10 | 06-MAR-05:00 | 178035.86 | 30-JUN-17:15 |
EnergyTransfer:Building | 810.37 | 2395.98 | 10-FEB-14:15 | 77876.41 | 29-JUN-17:30 |
EnergyTransfer:Zone:G SW APARTMENT | 19.04 | 0.02 | 22-DEC-01:00 | 2704.86 | 22-JUL-17:30 |
Heating:EnergyTransfer | 14.45 | 0.00 | 01-FEB-14:30 | 10780.94 | 07-DEC-05:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.34 | 0.00 | 01-JAN-08:30 | 470.07 | 07-DEC-05:00 |
Cooling:EnergyTransfer | 795.92 | 19.80 | 10-FEB-09:15 | 77637.43 | 30-JUN-17:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 18.70 | 0.00 | 01-JAN-00:15 | 2704.86 | 22-JUL-17:30 |
EnergyTransfer:Zone:G NW APARTMENT | 15.35 | 0.00 | 07-DEC-21:30 | 2756.88 | 30-JUN-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 1.03 | 0.00 | 01-JAN-11:45 | 666.59 | 07-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 14.33 | 0.00 | 01-JAN-00:15 | 2756.88 | 30-JUN-17:30 |
EnergyTransfer:Zone:OFFICE | 31.98 | 0.00 | 20-JAN-07:45 | 4603.18 | 18-SEP-10:30 |
Heating:EnergyTransfer:Zone:OFFICE | 6.55 | 0.00 | 01-JAN-00:15 | 943.96 | 27-JUN-17:30 |
Cooling:EnergyTransfer:Zone:OFFICE | 25.43 | 0.00 | 01-JAN-11:45 | 4603.18 | 18-SEP-10:30 |
EnergyTransfer:Zone:G NE APARTMENT | 15.52 | 0.01 | 16-APR-05:00 | 2110.35 | 29-JUN-18:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.80 | 0.00 | 01-JAN-08:45 | 701.21 | 07-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 14.72 | 0.00 | 01-JAN-00:15 | 2110.35 | 29-JUN-18:00 |
EnergyTransfer:Zone:G N1 APARTMENT | 11.26 | 0.00 | 12-JAN-11:45 | 1595.53 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.38 | 0.00 | 01-JAN-10:15 | 314.05 | 07-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 10.88 | 0.00 | 01-JAN-00:15 | 1595.53 | 30-JUN-18:45 |
EnergyTransfer:Zone:G N2 APARTMENT | 11.27 | 0.00 | 11-OCT-02:45 | 1586.16 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.38 | 0.00 | 01-JAN-10:15 | 316.33 | 07-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 10.89 | 0.00 | 01-JAN-00:15 | 1586.16 | 30-JUN-18:45 |
EnergyTransfer:Zone:G S1 APARTMENT | 15.06 | 0.01 | 14-FEB-14:45 | 1850.18 | 28-SEP-13:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 253.55 | 06-DEC-01:30 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 15.02 | 0.00 | 02-JAN-18:00 | 1850.18 | 28-SEP-13:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 15.79 | 0.02 | 13-NOV-11:15 | 1873.99 | 28-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 250.19 | 06-DEC-05:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 15.76 | 0.00 | 02-JAN-17:45 | 1873.99 | 28-SEP-13:30 |
EnergyTransfer:Zone:M SW APARTMENT | 68.33 | 0.42 | 08-MAR-10:00 | 6489.37 | 10-OCT-15:30 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 259.05 | 10-FEB-09:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 68.32 | 0.00 | 24-JAN-05:00 | 6489.37 | 10-OCT-15:30 |
EnergyTransfer:Zone:M NW APARTMENT | 52.10 | 0.03 | 12-DEC-04:45 | 6620.58 | 29-JUN-18:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 407.67 | 08-DEC-16:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 51.96 | 0.00 | 01-JAN-12:15 | 6620.58 | 29-JUN-18:30 |
EnergyTransfer:Zone:M SE APARTMENT | 69.57 | 1.16 | 11-FEB-11:30 | 5455.69 | 28-SEP-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 220.05 | 12-NOV-11:30 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 69.57 | 0.00 | 10-FEB-06:15 | 5455.69 | 28-SEP-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 53.22 | 0.01 | 18-DEC-11:30 | 5293.53 | 29-JUN-18:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 333.15 | 09-DEC-13:45 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 53.15 | 0.00 | 01-JAN-02:15 | 5293.53 | 29-JUN-18:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 43.50 | 0.05 | 29-MAR-11:30 | 3986.67 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 209.71 | 09-DEC-13:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 43.49 | 0.00 | 02-JAN-10:30 | 3986.67 | 30-JUN-18:45 |
EnergyTransfer:Zone:M N2 APARTMENT | 43.53 | 0.02 | 03-FEB-14:45 | 3971.94 | 30-JUN-18:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 208.75 | 09-DEC-13:45 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 43.52 | 0.00 | 02-JAN-10:30 | 3971.94 | 30-JUN-18:45 |
EnergyTransfer:Zone:M S1 APARTMENT | 60.47 | 8.46 | 08-MAR-11:15 | 4907.87 | 20-NOV-13:30 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 60.47 | 8.46 | 08-MAR-11:15 | 4907.87 | 20-NOV-13:30 |
EnergyTransfer:Zone:M S2 APARTMENT | 60.50 | 7.26 | 08-MAR-11:15 | 4913.60 | 20-NOV-13:30 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 60.50 | 7.26 | 08-MAR-11:15 | 4913.60 | 20-NOV-13:30 |
EnergyTransfer:Zone:T SW APARTMENT | 33.91 | 0.03 | 26-JAN-05:30 | 4111.02 | 28-JUN-17:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.77 | 0.00 | 01-JAN-09:00 | 1078.72 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 33.14 | 0.00 | 01-JAN-00:15 | 4111.02 | 28-JUN-17:15 |
EnergyTransfer:Zone:T NW APARTMENT | 27.77 | 0.01 | 25-DEC-11:45 | 4253.12 | 29-JUN-17:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 1.45 | 0.00 | 01-JAN-15:30 | 1302.82 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 26.32 | 0.00 | 01-JAN-00:15 | 4253.12 | 29-JUN-17:30 |
EnergyTransfer:Zone:T SE APARTMENT | 34.03 | 0.00 | 03-JAN-00:45 | 3441.45 | 28-SEP-13:45 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.54 | 0.00 | 01-JAN-08:30 | 1097.39 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 33.48 | 0.00 | 01-JAN-00:15 | 3441.45 | 28-SEP-13:45 |
EnergyTransfer:Zone:T NE APARTMENT | 27.37 | 0.00 | 31-JAN-01:45 | 3387.81 | 30-JUN-16:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.97 | 0.00 | 01-JAN-10:30 | 1350.20 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 26.40 | 0.00 | 01-JAN-00:15 | 3387.81 | 30-JUN-16:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 21.73 | 0.01 | 16-DEC-13:00 | 2713.87 | 29-JUN-18:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.36 | 0.00 | 01-JAN-11:15 | 814.87 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 21.37 | 0.00 | 01-JAN-00:15 | 2713.87 | 29-JUN-18:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 21.75 | 0.01 | 07-JAN-07:00 | 2696.86 | 29-JUN-18:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.35 | 0.00 | 01-JAN-11:15 | 819.42 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 21.40 | 0.00 | 01-JAN-00:15 | 2696.86 | 29-JUN-18:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 28.64 | 0.01 | 19-NOV-05:30 | 2937.26 | 28-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 566.40 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 28.53 | 0.00 | 01-JAN-02:15 | 2937.26 | 28-SEP-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 28.67 | 0.01 | 07-JAN-00:30 | 2943.53 | 28-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 566.32 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 28.56 | 0.00 | 01-JAN-02:15 | 2943.53 | 28-SEP-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 1041.67 | 0.00 | 10-FEB-09:00 | 101266.82 | 28-JUN-17:00 |
HeatingCoils:EnergyTransfer | 6.76 | 0.00 | 01-JAN-11:45 | 17918.37 | 07-DEC-05:00 |
CoolingCoils:EnergyTransfer | 1034.91 | 0.00 | 01-JAN-00:15 | 101266.82 | 28-JUN-17:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.338 | -18.698 | 0.000 | 0.000 | 3.648 | 2.413 | 12.213 | 18.632 | 0.000 | 0.663 | 0.000 | 0.000 | -5.000 | 0.000 | -1.704 | -12.505 |
G NW APARTMENT | 1.026 | -14.328 | 0.000 | 0.000 | 3.685 | 2.413 | 12.213 | 11.218 | 0.000 | 0.660 | 0.000 | 0.000 | -5.019 | 0.000 | -1.534 | -10.335 |
OFFICE | 6.547 | -25.432 | 0.000 | 0.000 | 0.517 | 21.914 | 7.534 | 18.202 | 0.000 | 0.429 | 0.000 | 0.000 | -5.498 | 0.000 | -0.991 | -23.222 |
G NE APARTMENT | 0.797 | -14.723 | 0.000 | 0.000 | 3.697 | 2.413 | 12.213 | 11.337 | 0.000 | 0.660 | 0.000 | 0.000 | -4.699 | 0.000 | -1.523 | -10.172 |
G N1 APARTMENT | 0.383 | -10.877 | 0.000 | 0.000 | 3.698 | 2.413 | 12.213 | 4.482 | 0.000 | 0.415 | 0.000 | 0.000 | -3.016 | 0.000 | -1.147 | -8.564 |
G N2 APARTMENT | 0.379 | -10.890 | 0.000 | 0.000 | 3.698 | 2.413 | 12.213 | 4.481 | 0.000 | 0.415 | 0.000 | 0.000 | -3.014 | 0.000 | -1.147 | -8.547 |
G S1 APARTMENT | 0.040 | -15.021 | 0.000 | 0.000 | 3.645 | 2.413 | 12.213 | 11.981 | 0.000 | 0.415 | 0.000 | 0.000 | -3.023 | 0.000 | -1.362 | -11.302 |
G S2 APARTMENT | 0.036 | -15.756 | 0.000 | 0.000 | 3.643 | 2.413 | 12.213 | 11.968 | 0.000 | 0.415 | 0.000 | 0.000 | -3.033 | 0.000 | -1.367 | -10.532 |
M SW APARTMENT | 0.010 | -68.322 | 0.000 | 0.000 | 3.534 | 2.413 | 12.213 | 18.030 | 0.000 | 0.943 | 39.236 | 0.000 | -5.722 | 0.000 | -2.334 | 0.000 |
M NW APARTMENT | 0.145 | -51.956 | 0.000 | 0.000 | 3.553 | 2.413 | 12.213 | 10.713 | 0.000 | 0.939 | 30.090 | 0.000 | -5.837 | 0.000 | -2.274 | -0.000 |
M SE APARTMENT | 0.007 | -69.565 | 0.000 | 0.000 | 3.537 | 2.413 | 12.213 | 18.285 | 0.000 | 0.943 | 40.056 | 0.000 | -5.557 | 0.000 | -2.331 | 0.000 |
M NE APARTMENT | 0.067 | -53.154 | 0.000 | 0.000 | 3.559 | 2.413 | 12.213 | 10.772 | 0.000 | 0.939 | 30.929 | 0.000 | -5.470 | 0.000 | -2.269 | -0.000 |
M N1 APARTMENT | 0.011 | -43.489 | 0.000 | 0.000 | 3.541 | 2.413 | 12.213 | 4.189 | 0.000 | 0.584 | 25.908 | 0.000 | -3.602 | 0.000 | -1.768 | 0.000 |
M N2 APARTMENT | 0.011 | -43.519 | 0.000 | 0.000 | 3.541 | 2.413 | 12.213 | 4.189 | 0.000 | 0.584 | 25.938 | 0.000 | -3.601 | 0.000 | -1.768 | 0.000 |
M S1 APARTMENT | 0.000 | -60.474 | 0.000 | 0.000 | 3.524 | 2.413 | 12.213 | 11.601 | 0.000 | 0.588 | 35.424 | 0.000 | -3.470 | 0.000 | -1.819 | 0.000 |
M S2 APARTMENT | 0.000 | -60.501 | 0.000 | 0.000 | 3.524 | 2.413 | 12.213 | 11.600 | 0.000 | 0.588 | 35.451 | 0.000 | -3.470 | 0.000 | -1.819 | 0.000 |
T SW APARTMENT | 0.772 | -33.141 | 0.000 | 0.000 | 3.599 | 2.413 | 12.213 | 17.725 | 0.000 | 1.235 | 3.383 | 0.000 | -5.384 | 0.000 | -2.815 | -0.000 |
T NW APARTMENT | 1.452 | -26.322 | 0.000 | 0.000 | 3.623 | 2.413 | 12.213 | 10.511 | 0.000 | 1.229 | 2.986 | 0.000 | -5.425 | 0.000 | -2.681 | -0.000 |
T SE APARTMENT | 0.543 | -33.484 | 0.000 | 0.000 | 3.605 | 2.413 | 12.213 | 17.994 | 0.000 | 1.235 | 3.521 | 0.000 | -5.226 | 0.000 | -2.814 | -0.000 |
T NE APARTMENT | 0.968 | -26.403 | 0.000 | 0.000 | 3.632 | 2.413 | 12.213 | 10.631 | 0.000 | 1.229 | 3.121 | 0.000 | -5.111 | 0.000 | -2.693 | -0.000 |
T N1 APARTMENT | 0.357 | -21.369 | 0.000 | 0.000 | 3.616 | 2.413 | 12.213 | 4.139 | 0.000 | 0.762 | 3.220 | 0.000 | -3.318 | 0.000 | -2.033 | -0.000 |
T N2 APARTMENT | 0.353 | -21.396 | 0.000 | 0.000 | 3.617 | 2.413 | 12.213 | 4.137 | 0.000 | 0.762 | 3.251 | 0.000 | -3.316 | 0.000 | -2.034 | -0.000 |
T S1 APARTMENT | 0.103 | -28.532 | 0.000 | 0.000 | 3.584 | 2.413 | 12.213 | 11.431 | 0.000 | 0.768 | 3.483 | 0.000 | -3.293 | 0.000 | -2.171 | -0.000 |
T S2 APARTMENT | 0.104 | -28.561 | 0.000 | 0.000 | 3.585 | 2.413 | 12.213 | 11.430 | 0.000 | 0.768 | 3.511 | 0.000 | -3.291 | 0.000 | -2.171 | -0.000 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.358 | 0.000 | 0.116 | 0.000 | 0.000 | -0.549 | 0.000 | -0.346 | -16.649 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 1.157 | 0.000 | 4.876 | 0.000 | 0.000 | -1.264 | 0.000 | -10.203 | -17.902 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.369 | 0.000 | 0.096 | 0.000 | 0.000 | -0.621 | 0.000 | -0.295 | -16.620 |
Total Facility | 14.451 | -795.914 | 0.000 | 0.000 | 83.405 | 128.627 | 294.692 | 271.563 | 0.000 | 23.256 | 289.508 | 0.000 | -105.828 | 0.000 | -57.408 | -146.352 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 22-JUL-17:25 | 0.00 | -2705.09 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1981.13 | 0.00 | 248.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -449.12 |
G NW APARTMENT | 30-JUN-17:25 | 0.00 | -2756.89 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 2174.23 | 0.00 | 252.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -594.50 |
OFFICE | 30-JUL-06:01 | 0.00 | -7772.75 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 545.57 | 0.00 | 0.00 | 6664.53 | 0.00 | 0.00 | 0.00 | -11.91 | 0.00 |
G NE APARTMENT | 29-JUN-17:45 | 0.00 | -2110.30 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1193.20 | 0.00 | 211.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -219.40 |
G N1 APARTMENT | 30-JUN-18:45 | 0.00 | -1595.39 | 0.00 | 0.00 | 141.06 | 230.46 | 547.42 | 727.47 | 0.00 | 117.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -168.73 |
G N2 APARTMENT | 30-JUN-18:45 | 0.00 | -1586.02 | 0.00 | 0.00 | 141.05 | 230.46 | 547.42 | 727.58 | 0.00 | 117.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -178.17 |
G S1 APARTMENT | 28-SEP-13:15 | 0.00 | -1849.84 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1898.69 | 0.00 | 28.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -529.55 |
G S2 APARTMENT | 28-SEP-13:30 | 0.00 | -1873.63 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1880.90 | 0.00 | 33.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -492.61 |
M SW APARTMENT | 10-OCT-15:30 | 0.00 | -6488.41 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 2814.44 | 0.00 | 162.11 | 2891.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 29-JUN-18:30 | 0.00 | -6620.21 | 0.00 | 0.00 | 141.06 | 230.46 | 547.42 | 2089.27 | 0.00 | 268.77 | 3343.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 28-SEP-13:30 | 0.00 | -5454.72 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2224.69 | 0.00 | 78.96 | 2698.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 29-JUN-18:00 | 0.00 | -5293.25 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 1192.26 | 0.00 | 298.46 | 2877.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 30-JUN-18:45 | 0.00 | -3986.33 | 0.00 | 0.00 | 141.12 | 230.46 | 547.42 | 717.75 | 0.00 | 168.86 | 2180.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 30-JUN-18:45 | 0.00 | -3971.60 | 0.00 | 0.00 | 141.11 | 230.46 | 547.42 | 717.82 | 0.00 | 168.85 | 2165.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 20-NOV-13:30 | 0.00 | -4907.19 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2341.69 | 0.00 | 46.71 | 2060.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 20-NOV-13:30 | 0.00 | -4912.92 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2341.66 | 0.00 | 46.71 | 2066.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 28-JUN-17:04 | 0.00 | -4111.48 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 2110.28 | 0.00 | 320.40 | 755.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 29-JUN-17:20 | 0.00 | -4253.51 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 2307.07 | 0.00 | 407.67 | 613.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 28-SEP-13:45 | 0.00 | -3440.83 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2125.06 | 0.00 | 119.65 | 743.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 30-JUN-16:03 | 0.00 | -3388.99 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 1059.32 | 0.00 | 532.85 | 979.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 29-JUN-18:30 | 0.00 | -2713.73 | 0.00 | 0.00 | 140.77 | 230.46 | 547.42 | 873.98 | 0.00 | 213.09 | 708.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-JUN-18:30 | 0.00 | -2696.71 | 0.00 | 0.00 | 140.76 | 230.46 | 547.42 | 874.22 | 0.00 | 213.09 | 690.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 28-SEP-13:30 | 0.00 | -2936.75 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1843.27 | 0.00 | 62.78 | 578.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 28-SEP-13:30 | 0.00 | -2943.03 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1843.17 | 0.00 | 62.78 | 584.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 30-JUN-17:04 | 0.00 | -77674.40 | 0.00 | 0.00 | 3261.35 | 6475.86 | 14071.03 | 24847.77 | 0.00 | 7954.64 | 21063.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 08-FEB-07:01 | 1369.05 | 0.00 | 0.00 | 0.00 | 162.55 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -568.09 | 0.00 | -35.94 | -1403.80 |
G NW APARTMENT | 27-NOV-07:01 | 815.24 | 0.00 | 0.00 | 0.00 | 162.09 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -512.51 | 0.00 | -72.36 | -868.69 |
OFFICE | 18-DEC-07:01 | 2863.01 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -707.29 | 0.00 | -109.66 | -2620.62 |
G NE APARTMENT | 23-JAN-07:01 | 784.72 | 0.00 | 0.00 | 0.00 | 162.07 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -460.75 | 0.00 | -96.53 | -865.73 |
G N1 APARTMENT | 05-DEC-07:08 | 728.18 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -504.22 | 0.00 | -21.13 | -840.28 |
G N2 APARTMENT | 05-DEC-06:06 | 592.88 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -482.09 | 0.00 | -16.32 | -702.82 |
G S1 APARTMENT | 07-DEC-06:23 | 616.32 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -533.78 | 0.00 | -78.77 | -612.13 |
G S2 APARTMENT | 06-DEC-05:15 | 500.38 | 0.00 | 0.00 | 0.00 | 189.67 | 93.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -525.30 | 0.00 | -60.73 | -450.75 |
M SW APARTMENT | 10-FEB-09:00 | 259.03 | 0.00 | 0.00 | 0.00 | 63.78 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 34.21 | 0.00 | -195.49 | 0.00 | -593.24 | 0.00 |
M NW APARTMENT | 08-DEC-16:00 | 407.65 | 0.00 | 0.00 | 0.00 | 40.94 | 50.41 | 400.26 | 242.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -167.17 | -974.47 |
M SE APARTMENT | 12-NOV-11:30 | 220.05 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -331.13 | 0.00 | -326.21 | -44.30 |
M NE APARTMENT | 09-DEC-13:45 | 333.16 | 0.00 | 0.00 | 0.00 | 41.10 | 28.81 | 388.49 | 226.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -72.73 | -944.96 |
M N1 APARTMENT | 09-DEC-13:45 | 209.71 | 0.00 | 0.00 | 0.00 | 41.02 | 28.81 | 388.49 | 134.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -68.37 | -734.52 |
M N2 APARTMENT | 09-DEC-13:45 | 208.76 | 0.00 | 0.00 | 0.00 | 41.01 | 28.81 | 388.49 | 134.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -68.44 | -733.41 |
M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 07-DEC-05:00 | 1078.72 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -913.46 | 0.00 | -285.53 | -336.28 |
T NW APARTMENT | 07-DEC-05:00 | 1302.82 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -881.74 | 0.00 | -285.53 | -592.11 |
T SE APARTMENT | 07-DEC-05:00 | 1097.39 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -928.40 | 0.00 | -285.53 | -340.01 |
T NE APARTMENT | 07-DEC-05:00 | 1350.20 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -895.73 | 0.00 | -285.53 | -625.49 |
T N1 APARTMENT | 31-MAR-06:01 | 1431.86 | 0.00 | 0.00 | 0.00 | 162.56 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -404.95 | 0.00 | -150.63 | -1515.07 |
T N2 APARTMENT | 31-MAR-06:01 | 1446.92 | 0.00 | 0.00 | 0.00 | 162.57 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -404.91 | 0.00 | -150.63 | -1530.18 |
T S1 APARTMENT | 07-DEC-05:00 | 566.40 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -565.07 | 0.00 | -172.23 | -285.66 |
T S2 APARTMENT | 07-DEC-05:00 | 566.32 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -565.06 | 0.00 | -172.23 | -285.59 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 07-DEC-07:01 | 6540.35 | 0.00 | 0.00 | 0.00 | 3680.84 | 4156.84 | 9398.91 | 0.00 | 0.00 | 0.00 | 6601.77 | 0.00 | -16120.72 | 0.00 | -14257.98 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Sec1.1A-General InformationData | |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 5.50 |
Number of hours cooling loads not met | 11.50 |
Number of hours not met | 17.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 8.45 | 22397.96 | 0.00 | 0.00 |
Space Cooling | 275.40 | 28729.72 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 273.07 | 8659.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 321.92 | 18074.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1586.25 | 8.45 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1586.25 |
Natural Gas | 0.00 | 8.45 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1594.69 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 87.86 |
Fans-Interior | 87.12 |
Service Water Heating | 102.70 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.58 |
Subtotal | 506.04 |
Natural Gas [MJ/m2] | |
Space Heating | 2.69 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 2.69 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 10.35 |
Space Heating | 0.53 |
Space Cooling | 17.27 |
Fans-Interior | 17.12 |
Service Water Heating | 20.19 |
Receptacle Equipment | 32.07 |
Miscellaneous | 2.47 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.242775 |
G NW APARTMENT DIRECT AIR | 0.243267 |
OFFICE DIRECT AIR | 0.522286 |
G NE APARTMENT DIRECT AIR | 0.195545 |
G N1 APARTMENT DIRECT AIR | 0.148254 |
G N2 APARTMENT DIRECT AIR | 0.147527 |
G S1 APARTMENT DIRECT AIR | 0.144917 |
G S2 APARTMENT DIRECT AIR | 0.147720 |
M SW APARTMENT DIRECT AIR | 0.578210 |
M NW APARTMENT DIRECT AIR | 0.576942 |
M SE APARTMENT DIRECT AIR | 0.502953 |
M NE APARTMENT DIRECT AIR | 0.477092 |
M N1 APARTMENT DIRECT AIR | 0.358114 |
M N2 APARTMENT DIRECT AIR | 0.356976 |
M S1 APARTMENT DIRECT AIR | 0.358124 |
M S2 APARTMENT DIRECT AIR | 0.359055 |
T SW APARTMENT DIRECT AIR | 0.373639 |
T NW APARTMENT DIRECT AIR | 0.366587 |
T SE APARTMENT DIRECT AIR | 0.329940 |
T NE APARTMENT DIRECT AIR | 0.301427 |
T N1 APARTMENT DIRECT AIR | 0.240700 |
T N2 APARTMENT DIRECT AIR | 0.239368 |
T S1 APARTMENT DIRECT AIR | 0.259322 |
T S2 APARTMENT DIRECT AIR | 0.259844 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.242775 |
SPLIT GNW MAIN BRANCH | 0.243267 |
SPLIT OFFICE MAIN BRANCH | 0.522286 |
SPLIT GNE MAIN BRANCH | 0.195545 |
SPLIT GN1 MAIN BRANCH | 0.148254 |
SPLIT GN2 MAIN BRANCH | 0.147527 |
SPLIT GS1 MAIN BRANCH | 0.144917 |
SPLIT GS2 MAIN BRANCH | 0.147720 |
SPLIT MSW MAIN BRANCH | 0.578210 |
SPLIT MNW MAIN BRANCH | 0.576942 |
SPLIT MSE MAIN BRANCH | 0.502953 |
SPLIT MNE MAIN BRANCH | 0.477092 |
SPLIT MN1 MAIN BRANCH | 0.358114 |
SPLIT MN2 MAIN BRANCH | 0.356976 |
SPLIT MS1 MAIN BRANCH | 0.358124 |
SPLIT MS2 MAIN BRANCH | 0.359055 |
SPLIT TSW MAIN BRANCH | 0.373639 |
SPLIT TNW MAIN BRANCH | 0.366587 |
SPLIT TSE MAIN BRANCH | 0.329940 |
SPLIT TNE MAIN BRANCH | 0.301427 |
SPLIT TN1 MAIN BRANCH | 0.240700 |
SPLIT TN2 MAIN BRANCH | 0.239368 |
SPLIT TS1 MAIN BRANCH | 0.259322 |
SPLIT TS2 MAIN BRANCH | 0.259844 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.242775 |
SPLIT GNW | 0.243267 |
SPLIT OFFICE | 0.522286 |
SPLIT GNE | 0.195545 |
SPLIT GN1 | 0.148254 |
SPLIT GN2 | 0.147527 |
SPLIT GS1 | 0.144917 |
SPLIT GS2 | 0.147720 |
SPLIT MSW | 0.578210 |
SPLIT MNW | 0.576942 |
SPLIT MSE | 0.502953 |
SPLIT MNE | 0.477092 |
SPLIT MN1 | 0.358114 |
SPLIT MN2 | 0.356976 |
SPLIT MS1 | 0.358124 |
SPLIT MS2 | 0.359055 |
SPLIT TSW | 0.373639 |
SPLIT TNW | 0.366587 |
SPLIT TSE | 0.329940 |
SPLIT TNE | 0.301427 |
SPLIT TN1 | 0.240700 |
SPLIT TN2 | 0.239368 |
SPLIT TS1 | 0.259322 |
SPLIT TS2 | 0.259844 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.242775 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.243267 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.522286 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.195545 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.148254 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.147527 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.144917 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.147720 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.578210 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.576942 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.502953 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.477092 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.358114 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.356976 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.358124 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.359055 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.373639 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.366587 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.329940 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.301427 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.240700 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.239368 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.259322 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.259844 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.242775 | 4056.05 | 0.795277 |
SPLIT GNW COOLING COIL | 0.243267 | 4026.93 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.522286 | 8645.68 | 0.798655 |
SPLIT GNE COOLING COIL | 0.195545 | 3236.96 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.148254 | 2454.13 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.147527 | 2442.10 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.144917 | 2616.46 | 0.768083 |
SPLIT GS2 COOLING COIL | 0.147720 | 2662.27 | 0.768690 |
SPLIT MSW COOLING COIL | 0.578210 | 9571.43 | 0.798655 |
SPLIT MNW COOLING COIL | 0.576942 | 9550.45 | 0.798655 |
SPLIT MSE COOLING COIL | 0.502953 | 8325.66 | 0.798655 |
SPLIT MNE COOLING COIL | 0.477092 | 7897.57 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.358114 | 5928.05 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.356976 | 5909.22 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.358124 | 6321.49 | 0.775783 |
SPLIT MS2 COOLING COIL | 0.359055 | 6336.70 | 0.775850 |
SPLIT TSW COOLING COIL | 0.373639 | 6185.05 | 0.798655 |
SPLIT TNW COOLING COIL | 0.366587 | 6068.31 | 0.798655 |
SPLIT TSE COOLING COIL | 0.329940 | 5583.73 | 0.790619 |
SPLIT TNE COOLING COIL | 0.301427 | 5118.57 | 0.789398 |
SPLIT TN1 COOLING COIL | 0.240700 | 3984.44 | 0.798655 |
SPLIT TN2 COOLING COIL | 0.239368 | 3962.40 | 0.798655 |
SPLIT TS1 COOLING COIL | 0.259322 | 4470.70 | 0.784017 |
SPLIT TS2 COOLING COIL | 0.259844 | 4479.25 | 0.784053 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.242775 | 0.242775 | 0.242775 | 0.242775 | 1597.54 | 4056.05 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.243267 | 0.243267 | 0.243267 | 0.243267 | 1563.28 | 4026.93 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.522286 | 0.522286 | 0.522286 | 0.522286 | 3186.88 | 8645.68 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.195545 | 0.195545 | 0.195545 | 0.195545 | 1571.49 | 3236.96 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.148254 | 0.148254 | 0.148254 | 0.148254 | 1411.22 | 2454.13 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.147527 | 0.147527 | 0.147527 | 0.147527 | 1411.22 | 2442.10 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.144917 | 0.144917 | 0.144917 | 0.144917 | 1411.22 | 2616.46 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.147720 | 0.147720 | 0.147720 | 0.147720 | 1411.22 | 2662.27 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.578210 | 0.578210 | 0.578210 | 0.578210 | 2944.04 | 9571.43 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.576942 | 0.576942 | 0.576942 | 0.576942 | 2913.99 | 9550.45 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.502953 | 0.502953 | 0.502953 | 0.502953 | 2965.14 | 8325.66 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.477092 | 0.477092 | 0.477092 | 0.477092 | 2935.09 | 7897.57 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.358114 | 0.358114 | 0.358114 | 0.358114 | 2822.44 | 5928.05 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.356976 | 0.356976 | 0.356976 | 0.356976 | 2822.44 | 5909.22 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.358124 | 0.358124 | 0.358124 | 0.358124 | 2822.44 | 6321.49 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.359055 | 0.359055 | 0.359055 | 0.359055 | 2822.44 | 6336.70 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.373639 | 0.373639 | 0.373639 | 0.373639 | 2327.97 | 6185.05 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.366587 | 0.366587 | 0.366587 | 0.366587 | 2312.80 | 6068.31 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.329940 | 0.329940 | 0.329940 | 0.329940 | 2339.37 | 5583.73 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.301427 | 0.301427 | 0.301427 | 0.301427 | 2324.21 | 5118.57 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.240700 | 0.240700 | 0.240700 | 0.240700 | 1757.84 | 3984.44 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.239368 | 0.239368 | 0.239368 | 0.239368 | 1758.04 | 3962.40 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.259322 | 0.259322 | 0.259322 | 0.259322 | 1772.94 | 4470.70 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.259844 | 0.259844 | 0.259844 | 0.259844 | 1773.14 | 4479.25 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.242775 |
SPLIT GNW SUPPLY FAN | 0.243267 |
SPLIT OFFICE SUPPLY FAN | 0.522286 |
SPLIT GNE SUPPLY FAN | 0.195545 |
SPLIT GN1 SUPPLY FAN | 0.148254 |
SPLIT GN2 SUPPLY FAN | 0.147527 |
SPLIT GS1 SUPPLY FAN | 0.144917 |
SPLIT GS2 SUPPLY FAN | 0.147720 |
SPLIT MSW SUPPLY FAN | 0.578210 |
SPLIT MNW SUPPLY FAN | 0.576942 |
SPLIT MSE SUPPLY FAN | 0.502953 |
SPLIT MNE SUPPLY FAN | 0.477092 |
SPLIT MN1 SUPPLY FAN | 0.358114 |
SPLIT MN2 SUPPLY FAN | 0.356976 |
SPLIT MS1 SUPPLY FAN | 0.358124 |
SPLIT MS2 SUPPLY FAN | 0.359055 |
SPLIT TSW SUPPLY FAN | 0.373639 |
SPLIT TNW SUPPLY FAN | 0.366587 |
SPLIT TSE SUPPLY FAN | 0.329940 |
SPLIT TNE SUPPLY FAN | 0.301427 |
SPLIT TN1 SUPPLY FAN | 0.240700 |
SPLIT TN2 SUPPLY FAN | 0.239368 |
SPLIT TS1 SUPPLY FAN | 0.259322 |
SPLIT TS2 SUPPLY FAN | 0.259844 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1597.54 |
SPLIT GNW HEATING COIL | 1563.28 |
SPLIT OFFICE HEATING COIL | 3186.88 |
SPLIT GNE HEATING COIL | 1571.49 |
SPLIT GN1 HEATING COIL | 1411.22 |
SPLIT GN2 HEATING COIL | 1411.22 |
SPLIT GS1 HEATING COIL | 1411.22 |
SPLIT GS2 HEATING COIL | 1411.22 |
SPLIT MSW HEATING COIL | 2944.04 |
SPLIT MNW HEATING COIL | 2913.99 |
SPLIT MSE HEATING COIL | 2965.14 |
SPLIT MNE HEATING COIL | 2935.09 |
SPLIT MN1 HEATING COIL | 2822.44 |
SPLIT MN2 HEATING COIL | 2822.44 |
SPLIT MS1 HEATING COIL | 2822.44 |
SPLIT MS2 HEATING COIL | 2822.44 |
SPLIT TSW HEATING COIL | 2327.97 |
SPLIT TNW HEATING COIL | 2312.80 |
SPLIT TSE HEATING COIL | 2339.37 |
SPLIT TNE HEATING COIL | 2324.21 |
SPLIT TN1 HEATING COIL | 1757.84 |
SPLIT TN2 HEATING COIL | 1758.04 |
SPLIT TS1 HEATING COIL | 1772.94 |
SPLIT TS2 HEATING COIL | 1773.14 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.47 | 14.83 |
February | 23.08 | 12.72 |
March | 23.37 | 15.42 |
April | 24.22 | 23.31 |
May | 24.36 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.12 | 20.87 |
November | 23.64 | 15.43 |
December | 23.13 | 11.86 |
Annual Sum or Average | 23.92 | 21.71 |
Minimum of Months | 23.08 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.94 | 14.83 |
February | 22.52 | 12.72 |
March | 23.10 | 15.42 |
April | 24.19 | 23.31 |
May | 24.37 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 23.96 | 20.87 |
November | 23.20 | 15.43 |
December | 22.48 | 11.86 |
Annual Sum or Average | 23.70 | 21.71 |
Minimum of Months | 22.48 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.13 | 14.83 |
February | 23.52 | 12.72 |
March | 24.09 | 15.42 |
April | 25.75 | 23.31 |
May | 26.21 | 26.31 |
June | 27.33 | 31.20 |
July | 27.43 | 30.42 |
August | 27.16 | 29.82 |
September | 27.29 | 27.75 |
October | 25.52 | 20.87 |
November | 24.28 | 15.43 |
December | 23.55 | 11.86 |
Annual Sum or Average | 25.53 | 21.71 |
Minimum of Months | 23.52 | 11.86 |
Maximum of Months | 27.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.89 | 14.83 |
February | 22.46 | 12.72 |
March | 23.09 | 15.42 |
April | 24.18 | 23.31 |
May | 24.36 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 23.95 | 20.87 |
November | 23.12 | 15.43 |
December | 22.41 | 11.86 |
Annual Sum or Average | 23.68 | 21.71 |
Minimum of Months | 22.41 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 14.83 |
February | 22.35 | 12.72 |
March | 22.94 | 15.42 |
April | 24.13 | 23.31 |
May | 24.35 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 23.92 | 20.87 |
November | 23.04 | 15.43 |
December | 22.33 | 11.86 |
Annual Sum or Average | 23.63 | 21.71 |
Minimum of Months | 22.33 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 14.83 |
February | 22.35 | 12.72 |
March | 22.94 | 15.42 |
April | 24.13 | 23.31 |
May | 24.35 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 23.92 | 20.87 |
November | 23.03 | 15.43 |
December | 22.33 | 11.86 |
Annual Sum or Average | 23.62 | 21.71 |
Minimum of Months | 22.33 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.54 | 14.83 |
February | 23.10 | 12.72 |
March | 23.35 | 15.42 |
April | 24.18 | 23.31 |
May | 24.34 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.14 | 20.87 |
November | 23.68 | 15.43 |
December | 23.20 | 11.86 |
Annual Sum or Average | 23.93 | 21.71 |
Minimum of Months | 23.10 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.55 | 14.83 |
February | 23.11 | 12.72 |
March | 23.37 | 15.42 |
April | 24.20 | 23.31 |
May | 24.35 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.15 | 20.87 |
November | 23.70 | 15.43 |
December | 23.21 | 11.86 |
Annual Sum or Average | 23.94 | 21.71 |
Minimum of Months | 23.11 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 14.83 |
February | 24.31 | 12.72 |
March | 24.27 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.39 | 20.87 |
November | 24.34 | 15.43 |
December | 24.13 | 11.86 |
Annual Sum or Average | 24.34 | 21.71 |
Minimum of Months | 24.13 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.10 | 14.83 |
February | 24.18 | 12.72 |
March | 24.20 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.37 | 20.87 |
November | 24.22 | 15.43 |
December | 23.74 | 11.86 |
Annual Sum or Average | 24.27 | 21.71 |
Minimum of Months | 23.74 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.28 | 14.83 |
February | 24.28 | 12.72 |
March | 24.26 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.38 | 20.87 |
November | 24.32 | 15.43 |
December | 24.10 | 11.86 |
Annual Sum or Average | 24.33 | 21.71 |
Minimum of Months | 24.10 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.06 | 14.83 |
February | 24.15 | 12.72 |
March | 24.19 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.36 | 20.87 |
November | 24.19 | 15.43 |
December | 23.70 | 11.86 |
Annual Sum or Average | 24.25 | 21.71 |
Minimum of Months | 23.70 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.19 | 14.83 |
February | 24.28 | 12.72 |
March | 24.28 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.39 | 20.87 |
November | 24.29 | 15.43 |
December | 23.93 | 11.86 |
Annual Sum or Average | 24.31 | 21.71 |
Minimum of Months | 23.93 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.19 | 14.83 |
February | 24.27 | 12.72 |
March | 24.28 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.39 | 20.87 |
November | 24.29 | 15.43 |
December | 23.93 | 11.86 |
Annual Sum or Average | 24.31 | 21.71 |
Minimum of Months | 23.93 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.37 | 14.83 |
February | 24.37 | 12.72 |
March | 24.33 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.40 | 20.87 |
November | 24.38 | 15.43 |
December | 24.27 | 11.86 |
Annual Sum or Average | 24.38 | 21.71 |
Minimum of Months | 24.27 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.37 | 14.83 |
February | 24.37 | 12.72 |
March | 24.33 | 15.42 |
April | 24.40 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.40 | 20.87 |
November | 24.38 | 15.43 |
December | 24.27 | 11.86 |
Annual Sum or Average | 24.38 | 21.71 |
Minimum of Months | 24.27 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.76 | 14.83 |
February | 23.70 | 12.72 |
March | 23.82 | 15.42 |
April | 24.36 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.23 | 20.87 |
November | 23.92 | 15.43 |
December | 23.42 | 11.86 |
Annual Sum or Average | 24.10 | 21.71 |
Minimum of Months | 23.42 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.44 | 14.83 |
February | 23.40 | 12.72 |
March | 23.69 | 15.42 |
April | 24.36 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.14 | 20.87 |
November | 23.67 | 15.43 |
December | 22.99 | 11.86 |
Annual Sum or Average | 23.98 | 21.71 |
Minimum of Months | 22.99 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.73 | 14.83 |
February | 23.66 | 12.72 |
March | 23.81 | 15.42 |
April | 24.36 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.22 | 20.87 |
November | 23.89 | 15.43 |
December | 23.41 | 11.86 |
Annual Sum or Average | 24.09 | 21.71 |
Minimum of Months | 23.41 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.45 | 14.83 |
February | 23.36 | 12.72 |
March | 23.69 | 15.42 |
April | 24.34 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.14 | 20.87 |
November | 23.65 | 15.43 |
December | 22.96 | 11.86 |
Annual Sum or Average | 23.97 | 21.71 |
Minimum of Months | 22.96 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 14.83 |
February | 23.44 | 12.72 |
March | 23.76 | 15.42 |
April | 24.36 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.17 | 20.87 |
November | 23.71 | 15.43 |
December | 22.97 | 11.86 |
Annual Sum or Average | 24.00 | 21.71 |
Minimum of Months | 22.97 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 14.83 |
February | 23.44 | 12.72 |
March | 23.75 | 15.42 |
April | 24.36 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.17 | 20.87 |
November | 23.70 | 15.43 |
December | 22.97 | 11.86 |
Annual Sum or Average | 23.99 | 21.71 |
Minimum of Months | 22.97 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.90 | 14.83 |
February | 23.84 | 12.72 |
March | 23.92 | 15.42 |
April | 24.37 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.27 | 20.87 |
November | 24.02 | 15.43 |
December | 23.55 | 11.86 |
Annual Sum or Average | 24.16 | 21.71 |
Minimum of Months | 23.55 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 14.83 |
February | 23.84 | 12.72 |
March | 23.92 | 15.42 |
April | 24.37 | 23.31 |
May | 24.40 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.27 | 20.87 |
November | 24.02 | 15.43 |
December | 23.55 | 11.86 |
Annual Sum or Average | 24.16 | 21.71 |
Minimum of Months | 23.55 | 11.86 |
Maximum of Months | 24.40 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.89 | 14.83 |
February | 24.66 | 12.72 |
March | 25.16 | 15.42 |
April | 26.60 | 23.31 |
May | 26.92 | 26.31 |
June | 27.53 | 31.20 |
July | 27.51 | 30.42 |
August | 27.40 | 29.82 |
September | 27.20 | 27.75 |
October | 26.13 | 20.87 |
November | 25.17 | 15.43 |
December | 24.10 | 11.86 |
Annual Sum or Average | 26.11 | 21.71 |
Minimum of Months | 24.10 | 11.86 |
Maximum of Months | 27.53 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.07 | 14.83 |
February | 22.23 | 12.72 |
March | 23.14 | 15.42 |
April | 25.29 | 23.31 |
May | 26.04 | 26.31 |
June | 27.82 | 31.20 |
July | 27.76 | 30.42 |
August | 27.64 | 29.82 |
September | 27.29 | 27.75 |
October | 24.95 | 20.87 |
November | 23.34 | 15.43 |
December | 22.25 | 11.86 |
Annual Sum or Average | 25.08 | 21.71 |
Minimum of Months | 22.23 | 11.86 |
Maximum of Months | 27.82 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.36 | 14.83 |
February | 26.26 | 12.72 |
March | 26.38 | 15.42 |
April | 26.94 | 23.31 |
May | 27.06 | 26.31 |
June | 27.30 | 31.20 |
July | 27.24 | 30.42 |
August | 27.20 | 29.82 |
September | 27.12 | 27.75 |
October | 26.81 | 20.87 |
November | 26.47 | 15.43 |
December | 26.00 | 11.86 |
Annual Sum or Average | 26.77 | 21.71 |
Minimum of Months | 26.00 | 11.86 |
Maximum of Months | 27.30 | 31.20 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:29
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.126016E+12 | 76199.587 | 31-JAN-18:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 9348.519 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20654.462 | 0.000 | 0.000 | 0.000 |
February | 0.109523E+12 | 74272.834 | 27-FEB-18:15 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 4340.082 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23736.145 | 0.000 | 0.000 | 0.000 |
March | 0.122959E+12 | 77745.071 | 16-MAR-17:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 13306.118 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20750.677 | 0.000 | 0.000 | 0.000 |
April | 0.131537E+12 | 83275.799 | 03-APR-17:15 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 18742.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20844.866 | 0.000 | 0.000 | 0.000 |
May | 0.138836E+12 | 86534.124 | 07-MAY-17:15 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 21938.304 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20907.544 | 0.000 | 0.000 | 0.000 |
June | 0.145410E+12 | 90492.248 | 29-JUN-17:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 28729.722 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18074.249 | 0.000 | 0.000 | 0.000 |
July | 0.149664E+12 | 89326.785 | 20-JUL-17:15 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 27578.332 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18060.176 | 0.000 | 0.000 | 0.000 |
August | 0.148523E+12 | 90054.025 | 26-AUG-17:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 26650.013 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19715.736 | 0.000 | 0.000 | 0.000 |
September | 0.140929E+12 | 86453.894 | 06-SEP-17:15 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 23097.647 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19667.970 | 0.000 | 0.000 | 0.000 |
October | 0.131192E+12 | 83638.027 | 04-OCT-17:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 18836.140 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21113.610 | 0.000 | 0.000 | 0.000 |
November | 0.119967E+12 | 74053.256 | 09-NOV-18:30 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 8594.257 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19262.393 | 0.000 | 0.000 | 0.000 |
December | 0.121690E+12 | 72851.925 | 29-DEC-18:00 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 4231.143 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22424.175 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.158625E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.109523E+12 | 72851.925 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 4231.143 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18060.176 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.149664E+12 | 90492.248 | 8572.775 | 26456.413 | 8659.089 | 0.000 | 28729.722 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23736.145 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:29
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.111521E+10 | 15468.029 | 01-JAN-04:00 | 15468.029 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 15468.029 |
February | 0.922962E+09 | 7705.597 | 05-FEB-03:00 | 7705.597 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 7705.597 |
March | 0.111478E+10 | 13225.625 | 26-MAR-06:15 | 13225.625 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13225.625 |
April | 0.000 | 0.000 | 01-APR-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.000 | 0.000 | 01-MAY-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.176136E+08 | 1907.973 | 26-OCT-03:00 | 1907.973 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1907.973 |
November | 0.670683E+09 | 11076.773 | 23-NOV-06:00 | 11076.773 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 11076.773 |
December | 0.460564E+10 | 22397.965 | 07-DEC-04:00 | 22397.965 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22397.965 |
Annual Sum or Average | 0.844689E+10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.460564E+10 | 22397.965 | 22397.965 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22397.965 |