Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Albuquerque Intl Sunport NM USA TMY3 WMO#=723650
Simulation Timestamp: 2018-10-19 09:20:29
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1599.12 | 510.15 | 566.27 |
Net Site Energy | 1599.12 | 510.15 | 566.27 |
Total Source Energy | 4899.11 | 1562.91 | 1734.83 |
Net Source Energy | 4899.11 | 1562.91 | 1734.83 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 79.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 163.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 255.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 385.56 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1519.76 | 79.36 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 79.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 163.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 255.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 385.56 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 284.68 | 28.10 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 538.16 | 28.10 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 256.47 | 25.32 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 484.83 | 25.32 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1519.76 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1519.76 | 100.00 |
Total On-Site and Utility Electric Sources | 1519.76 | 100.00 |
Total Electricity End Uses | 1519.76 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 39.75 |
Time Setpoint Not Met During Occupied Cooling | 0.75 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1322.25 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | Albuquerque Intl Sunport NM USA TMY3 WMO#=723650 |
Weather File | Albuquerque Intl Sunport NM USA TMY3 WMO#=723650 |
Latitude [deg] | 35.04 |
Longitude [deg] | -106.6 |
Elevation [m] | 1619.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 20-AUG-17:30 | 18-JAN-01:15 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 42678.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 21666.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 8096.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 23202.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 87995.81 | 42678.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 42678.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 21666.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 8096.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 23202.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 86.02 | 0.00 | 0.00 | 0.00 |
Cooling | 516.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 808.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1221.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4813.09 | 86.02 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 30.46 | 0.00 | 0.00 | 0.00 |
Cooling | 182.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 286.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 432.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1704.37 | 30.46 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 30.46 | 0.00 | 0.00 | 0.00 |
Cooling | 182.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 286.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 432.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1704.37 | 30.46 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | -7.90 | 0.00 | -7.90 | Wetbulb [C] | 3.20 | 0.00 |
ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 35.10 | 13.50 | 15.70 | Wetbulb [C] | 4.40 | 220.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.52_SHGC_0.40 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.70 | 83.70 | 39.41 | |
Exterior Lighting Total | 2508.33 | 39.41 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3407.97 | 2721.79 | 686.18 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3397.93 | 2713.77 | 684.16 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8514.37 | 6800.05 | 1714.32 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2509.14 | 2003.94 | 505.20 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2053.06 | 1639.69 | 413.37 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2032.55 | 1623.31 | 409.24 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1995.51 | 1593.73 | 401.79 | 0.80 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2026.42 | 1618.41 | 408.01 | 0.80 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9076.89 | 7249.30 | 1827.58 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8993.35 | 7182.59 | 1810.76 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7471.10 | 5966.83 | 1504.27 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7005.45 | 5594.94 | 1410.51 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5615.31 | 4484.70 | 1130.61 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5580.82 | 4457.15 | 1123.67 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5547.64 | 4430.65 | 1116.99 | 0.80 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5513.46 | 4403.35 | 1110.11 | 0.80 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6157.85 | 4918.00 | 1239.85 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5998.02 | 4790.35 | 1207.67 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5437.43 | 4342.63 | 1094.80 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4852.86 | 3875.76 | 977.10 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3869.94 | 3090.75 | 779.19 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3838.70 | 3065.80 | 772.90 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4376.16 | 3495.05 | 881.12 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4387.26 | 3503.91 | 883.35 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3246.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3237.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8111.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2390.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1955.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1936.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1901.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1930.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8647.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8567.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7117.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6673.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5349.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5316.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5285.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5252.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5866.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5714.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5180.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4623.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3686.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3657.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4169.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4179.6 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1938.43 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1918.34 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 3769.06 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1918.34 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1495.50 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1495.50 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1495.50 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1495.97 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 3799.60 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 3824.72 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 3799.60 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 3824.72 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 3053.00 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 3067.67 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 3053.00 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 3067.67 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 2398.91 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 2398.91 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 2382.27 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 2382.27 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 230.60 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 229.92 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.51 | 576.13 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 169.78 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.12 | 138.92 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.12 | 137.53 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.12 | 135.03 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.12 | 137.12 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.55 | 614.19 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.54 | 608.54 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 505.54 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 474.03 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 379.96 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 377.63 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 375.39 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 373.07 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 416.68 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 405.86 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 367.93 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.37 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 261.86 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 259.75 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 296.12 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 296.87 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1801.99 | 2162.39 | 0.172 | 0.206 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
G NW APARTMENT | 1796.68 | 2156.01 | 0.171 | 0.205 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
OFFICE | 4285.67 | 5142.81 | 0.429 | 0.514 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 28.82 | 0.00565 |
G NE APARTMENT | 1326.72 | 1592.07 | 0.126 | 0.152 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.35 | 0.00565 |
G N1 APARTMENT | 1085.56 | 1302.67 | 0.103 | 0.124 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 30.34 | 0.00565 |
G N2 APARTMENT | 1074.72 | 1289.66 | 0.102 | 0.123 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 30.34 | 0.00565 |
G S1 APARTMENT | 1055.13 | 1266.16 | 0.100 | 0.121 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 30.85 | 0.00565 |
G S2 APARTMENT | 1071.47 | 1285.76 | 0.102 | 0.122 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 29.84 | 0.00565 |
M SW APARTMENT | 4799.51 | 5759.41 | 0.457 | 0.548 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
M NW APARTMENT | 4755.31 | 5706.38 | 0.453 | 0.543 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
M SE APARTMENT | 3950.46 | 4740.55 | 0.376 | 0.451 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.76 | 0.00565 |
M NE APARTMENT | 3704.19 | 4445.03 | 0.353 | 0.423 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.35 | 0.00565 |
M N1 APARTMENT | 2969.12 | 3562.94 | 0.283 | 0.339 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 30.34 | 0.00565 |
M N2 APARTMENT | 2950.88 | 3541.05 | 0.281 | 0.337 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 30.34 | 0.00565 |
M S1 APARTMENT | 2933.34 | 3520.01 | 0.279 | 0.335 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
M S2 APARTMENT | 2915.27 | 3498.32 | 0.278 | 0.333 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
T SW APARTMENT | 3256.10 | 3907.32 | 0.310 | 0.372 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 33.48 | 0.00565 |
T NW APARTMENT | 3171.56 | 3805.87 | 0.302 | 0.362 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
T SE APARTMENT | 2875.16 | 3450.20 | 0.274 | 0.328 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.93 | 0.00565 |
T NE APARTMENT | 2566.06 | 3079.27 | 0.244 | 0.293 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 35.10 | 0.00565 |
T N1 APARTMENT | 2046.26 | 2455.51 | 0.195 | 0.234 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
T N2 APARTMENT | 2029.76 | 2435.72 | 0.193 | 0.232 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 35.10 | 0.00565 |
T S1 APARTMENT | 2313.95 | 2776.74 | 0.220 | 0.264 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 35.10 | 0.00565 |
T S2 APARTMENT | 2319.82 | 2783.78 | 0.221 | 0.265 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 35.10 | 0.00565 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 969.17 | 1163.00 | 0.034 | 0.041 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
G NW APARTMENT | 975.73 | 1170.88 | 0.034 | 0.041 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
OFFICE | 2281.41 | 2737.69 | 0.077 | 0.092 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G NE APARTMENT | 975.73 | 1170.88 | 0.034 | 0.041 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
G N1 APARTMENT | 541.76 | 650.11 | 0.019 | 0.026 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
G N2 APARTMENT | 541.76 | 650.11 | 0.019 | 0.026 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
G S1 APARTMENT | 536.47 | 643.76 | 0.019 | 0.026 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
G S2 APARTMENT | 618.54 | 742.25 | 0.022 | 0.026 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M SW APARTMENT | 1920.13 | 2304.15 | 0.067 | 0.081 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M NW APARTMENT | 1941.37 | 2329.64 | 0.068 | 0.082 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M SE APARTMENT | 1920.13 | 2304.15 | 0.067 | 0.081 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M NE APARTMENT | 1941.37 | 2329.64 | 0.068 | 0.082 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M N1 APARTMENT | 850.86 | 1021.03 | 0.030 | 0.052 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M N2 APARTMENT | 850.86 | 1021.03 | 0.030 | 0.052 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M S1 APARTMENT | 831.08 | 997.30 | 0.029 | 0.052 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M S2 APARTMENT | 831.08 | 997.30 | 0.029 | 0.052 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T SW APARTMENT | 1935.28 | 2322.34 | 0.068 | 0.081 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T NW APARTMENT | 1947.69 | 2337.23 | 0.068 | 0.082 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T SE APARTMENT | 1935.28 | 2322.34 | 0.068 | 0.081 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T NE APARTMENT | 1947.69 | 2337.23 | 0.068 | 0.082 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T N1 APARTMENT | 1382.13 | 1658.56 | 0.048 | 0.058 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T N2 APARTMENT | 1382.13 | 1658.56 | 0.048 | 0.058 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T S1 APARTMENT | 1368.06 | 1641.67 | 0.048 | 0.057 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T S2 APARTMENT | 1368.06 | 1641.67 | 0.048 | 0.057 | ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.21 | 0.21 | 0.04 | 0.04 |
SPLIT GNW | 0.21 | 0.21 | 0.04 | 0.04 |
SPLIT OFFICE | 0.51 | 0.51 | 0.09 | 0.09 |
SPLIT GNE | 0.15 | 0.15 | 0.04 | 0.04 |
SPLIT GN1 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT GN2 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT GS1 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT GS2 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT MSW | 0.55 | 0.55 | 0.08 | 0.08 |
SPLIT MNW | 0.54 | 0.54 | 0.08 | 0.08 |
SPLIT MSE | 0.45 | 0.45 | 0.08 | 0.08 |
SPLIT MNE | 0.42 | 0.42 | 0.08 | 0.08 |
SPLIT MN1 | 0.34 | 0.34 | 0.05 | 0.05 |
SPLIT MN2 | 0.34 | 0.34 | 0.05 | 0.05 |
SPLIT MS1 | 0.34 | 0.34 | 0.05 | 0.05 |
SPLIT MS2 | 0.33 | 0.33 | 0.05 | 0.05 |
SPLIT TSW | 0.37 | 0.37 | 0.08 | 0.08 |
SPLIT TNW | 0.36 | 0.36 | 0.08 | 0.08 |
SPLIT TSE | 0.33 | 0.33 | 0.08 | 0.08 |
SPLIT TNE | 0.29 | 0.29 | 0.08 | 0.08 |
SPLIT TN1 | 0.23 | 0.23 | 0.06 | 0.06 |
SPLIT TN2 | 0.23 | 0.23 | 0.06 | 0.06 |
SPLIT TS1 | 0.26 | 0.26 | 0.06 | 0.06 |
SPLIT TS2 | 0.27 | 0.27 | 0.06 | 0.06 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2224.25 | 5597.75 | 117.75 |
G NW APARTMENT | 2538.25 | 5810.00 | 610.50 |
OFFICE | 376.75 | 1472.25 | 3.25 |
G NE APARTMENT | 2572.00 | 5779.75 | 606.75 |
G N1 APARTMENT | 1894.25 | 5965.75 | 249.25 |
G N2 APARTMENT | 1897.50 | 5964.00 | 250.00 |
G S1 APARTMENT | 1999.00 | 5786.00 | 74.50 |
G S2 APARTMENT | 1959.00 | 5808.00 | 84.50 |
M SW APARTMENT | 3008.75 | 2904.00 | 0.50 |
M NW APARTMENT | 2825.75 | 4296.50 | 11.75 |
M SE APARTMENT | 3019.25 | 2905.00 | 1.00 |
M NE APARTMENT | 2836.00 | 4291.75 | 12.75 |
M N1 APARTMENT | 2597.75 | 4352.50 | 3.25 |
M N2 APARTMENT | 2602.00 | 4349.75 | 3.00 |
M S1 APARTMENT | 2826.50 | 2408.25 | 3.25 |
M S2 APARTMENT | 2830.75 | 2422.25 | 3.25 |
T SW APARTMENT | 3417.75 | 3957.75 | 414.75 |
T NW APARTMENT | 3752.00 | 4773.25 | 1066.75 |
T SE APARTMENT | 3424.75 | 3872.75 | 424.50 |
T NE APARTMENT | 3760.25 | 4779.75 | 1069.50 |
T N1 APARTMENT | 3315.25 | 4904.50 | 753.50 |
T N2 APARTMENT | 3326.25 | 4902.50 | 763.00 |
T S1 APARTMENT | 2978.75 | 3930.25 | 183.00 |
T S2 APARTMENT | 2984.25 | 3927.25 | 185.25 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 4821.75 | 6053.00 | 1322.25 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 4.25 | 0.00 | 4.25 | 0.00 |
G NW APARTMENT | 6.00 | 0.25 | 6.00 | 0.25 |
OFFICE | 0.75 | 1.75 | 0.00 | 0.00 |
G NE APARTMENT | 8.25 | 0.00 | 8.25 | 0.00 |
G N1 APARTMENT | 3.75 | 0.00 | 3.75 | 0.00 |
G N2 APARTMENT | 3.50 | 0.00 | 3.50 | 0.00 |
G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S2 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M SW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M NW APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 0.00 | 0.25 | 0.00 | 0.25 |
T NW APARTMENT | 0.00 | 0.25 | 0.00 | 0.25 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 2.75 | 0.00 | 2.75 | 0.00 |
T N2 APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T S1 APARTMENT | 2.75 | 0.00 | 2.75 | 0.00 |
T S2 APARTMENT | 4.00 | 0.00 | 4.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 40.50 | 2.50 | 39.75 | 0.75 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.365 | 0.097 | 0.000 | 0.081 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.097 | 0.000 | 0.077 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.517 | 0.100 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.097 | 0.000 | 0.077 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.058 | 0.000 | 0.076 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.058 | 0.000 | 0.076 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.058 | 0.000 | 0.081 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.058 | 0.000 | 0.081 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.139 | 0.000 | 0.100 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.139 | 0.000 | 0.096 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.139 | 0.000 | 0.100 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.139 | 0.000 | 0.096 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.084 | 0.000 | 0.096 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.084 | 0.000 | 0.096 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.084 | 0.000 | 0.100 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.084 | 0.000 | 0.100 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.184 | 0.000 | 0.122 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.184 | 0.000 | 0.116 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.184 | 0.000 | 0.122 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.184 | 0.000 | 0.116 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.116 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.116 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.122 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.122 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.502 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.372 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.372 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.375 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.375 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1519.76 | 21467.12 | 01-JAN-03:15 | 87995.81 | 20-AUG-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 385.56 | 0.00 | 01-JAN-00:15 | 32443.48 | 01-JAN-07:45 |
WaterSystems:Electricity | 385.56 | 0.00 | 01-JAN-00:15 | 32443.48 | 01-JAN-07:45 |
Water Heater:WaterSystems:Electricity | 385.56 | 0.00 | 01-JAN-00:15 | 32443.48 | 01-JAN-07:45 |
Fans:Electricity | 255.34 | 8096.82 | 07-JAN-02:00 | 8096.82 | 07-JAN-17:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
ElectricityPurchased:Plant | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
Cogeneration:ElectricityPurchased | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
ElectricityNet:Plant | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
Cogeneration:ElectricityNet | 1519.76 | 21467.12 | 13-DEC-04:00 | 87995.81 | 20-AUG-17:30 |
ExteriorLights:Electricity | 39.41 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.41 | 0.00 | 01-JAN-07:30 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 418.37 | 8096.82 | 07-JAN-02:00 | 32262.75 | 28-JUN-16:15 |
General:Fans:Electricity | 255.34 | 8096.82 | 07-JAN-02:00 | 8096.82 | 07-JAN-17:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 163.03 | 0.00 | 01-JAN-00:15 | 24165.93 | 28-JUN-16:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 79.36 | 0.00 | 01-JAN-12:30 | 42678.60 | 18-JAN-01:15 |
Gas:HVAC | 79.36 | 0.00 | 01-JAN-12:30 | 42678.60 | 18-JAN-01:15 |
Heating:Gas | 79.36 | 0.00 | 01-JAN-12:30 | 42678.60 | 18-JAN-01:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1308.61 | 2739.67 | 10-NOV-14:15 | 149303.32 | 04-JUL-17:15 |
EnergyTransfer:Building | 611.61 | 1627.68 | 21-MAY-05:45 | 65888.42 | 04-JUL-17:15 |
EnergyTransfer:Zone:G SW APARTMENT | 11.98 | 0.00 | 11-MAY-13:15 | 2129.27 | 21-JUL-17:15 |
Heating:EnergyTransfer | 31.67 | 0.00 | 02-JAN-18:15 | 22568.40 | 18-JAN-01:15 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.79 | 0.00 | 01-JAN-00:15 | 839.45 | 18-JAN-01:15 |
Cooling:EnergyTransfer | 579.94 | 334.15 | 18-JAN-02:00 | 65888.42 | 04-JUL-17:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 11.18 | 0.00 | 01-JAN-01:45 | 2129.27 | 21-JUL-17:15 |
EnergyTransfer:Zone:G NW APARTMENT | 10.21 | 0.02 | 03-OCT-10:30 | 2119.25 | 04-JUL-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 2.19 | 0.00 | 01-JAN-12:00 | 995.74 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 8.02 | 0.00 | 01-JAN-00:15 | 2119.25 | 04-JUL-17:30 |
EnergyTransfer:Zone:OFFICE | 25.37 | 0.01 | 23-OCT-04:00 | 3442.03 | 21-SEP-13:30 |
Heating:EnergyTransfer:Zone:OFFICE | 0.26 | 0.00 | 01-JAN-00:15 | 1300.83 | 17-JAN-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 25.12 | 0.00 | 01-JAN-17:15 | 3442.03 | 21-SEP-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 10.56 | 0.02 | 11-MAY-12:30 | 1506.44 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 1.96 | 0.00 | 01-JAN-08:45 | 1014.31 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 8.60 | 0.00 | 01-JAN-00:15 | 1506.44 | 04-JUL-17:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 7.81 | 0.00 | 19-FEB-14:15 | 1207.04 | 04-JUL-18:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.75 | 0.00 | 01-JAN-10:15 | 537.54 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 7.06 | 0.00 | 01-JAN-00:15 | 1207.04 | 04-JUL-18:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 7.83 | 0.01 | 02-OCT-00:45 | 1193.69 | 04-JUL-18:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.75 | 0.00 | 01-JAN-10:15 | 539.22 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 7.07 | 0.00 | 01-JAN-00:15 | 1193.69 | 04-JUL-18:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 10.64 | 0.03 | 19-MAY-24:00 | 1420.65 | 21-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.13 | 0.00 | 01-JAN-00:15 | 423.33 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 10.51 | 0.00 | 07-JAN-02:45 | 1420.65 | 21-SEP-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 10.42 | 0.01 | 19-MAY-06:45 | 1408.26 | 21-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 447.38 | 18-JAN-01:30 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 10.27 | 0.00 | 07-JAN-02:30 | 1408.26 | 21-SEP-13:30 |
EnergyTransfer:Zone:M SW APARTMENT | 51.74 | 0.21 | 19-JAN-07:45 | 5709.27 | 20-SEP-16:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 1223.07 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 51.68 | 0.00 | 17-JAN-01:30 | 5709.27 | 20-SEP-16:15 |
EnergyTransfer:Zone:M NW APARTMENT | 35.89 | 0.11 | 24-DEC-16:15 | 5518.09 | 04-JUL-17:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.85 | 0.00 | 01-JAN-00:15 | 1816.37 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 35.04 | 0.00 | 01-JAN-12:30 | 5518.09 | 04-JUL-17:30 |
EnergyTransfer:Zone:M SE APARTMENT | 53.61 | 3.02 | 19-JAN-11:15 | 4761.81 | 21-SEP-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.08 | 0.00 | 01-JAN-00:15 | 1284.53 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 53.53 | 0.00 | 16-JAN-24:00 | 4761.81 | 21-SEP-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 38.16 | 0.01 | 18-JAN-10:00 | 4200.43 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.91 | 0.00 | 01-JAN-00:15 | 1952.01 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 37.25 | 0.00 | 01-JAN-03:00 | 4200.43 | 04-JUL-17:15 |
EnergyTransfer:Zone:M N1 APARTMENT | 32.73 | 0.24 | 05-JAN-15:45 | 3288.89 | 04-JUL-18:15 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 646.34 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 32.66 | 0.00 | 01-JAN-14:00 | 3288.89 | 04-JUL-18:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 32.78 | 0.31 | 28-OCT-13:00 | 3266.93 | 04-JUL-18:15 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.08 | 0.00 | 01-JAN-00:15 | 665.71 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 32.70 | 0.00 | 01-JAN-14:00 | 3266.93 | 04-JUL-18:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 50.03 | 4.72 | 09-NOV-15:45 | 4134.62 | 11-OCT-12:45 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 50.03 | 4.72 | 09-NOV-15:45 | 4134.62 | 11-OCT-12:45 |
EnergyTransfer:Zone:M S2 APARTMENT | 50.08 | 7.42 | 09-NOV-15:45 | 4140.94 | 11-OCT-12:45 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 50.08 | 7.42 | 09-NOV-15:45 | 4140.94 | 11-OCT-12:45 |
EnergyTransfer:Zone:T SW APARTMENT | 25.50 | 0.01 | 28-OCT-01:00 | 3725.97 | 21-JUL-16:30 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 2.77 | 0.00 | 01-JAN-00:15 | 1750.24 | 17-JAN-04:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 22.73 | 0.00 | 01-JAN-01:30 | 3725.97 | 21-JUL-16:30 |
EnergyTransfer:Zone:T NW APARTMENT | 21.50 | 0.00 | 10-MAR-20:30 | 3696.65 | 28-JUN-16:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 5.08 | 0.00 | 02-JAN-15:15 | 2007.05 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 16.42 | 0.00 | 01-JAN-00:15 | 3696.65 | 28-JUN-16:30 |
EnergyTransfer:Zone:T SE APARTMENT | 26.02 | 0.00 | 07-JAN-22:45 | 3332.27 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 2.67 | 0.00 | 01-JAN-00:15 | 1765.71 | 17-JAN-04:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 23.34 | 0.00 | 01-JAN-01:15 | 3332.27 | 03-SEP-13:30 |
EnergyTransfer:Zone:T NE APARTMENT | 21.75 | 0.01 | 16-MAR-22:45 | 2964.59 | 29-JUN-15:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 4.75 | 0.00 | 01-JAN-09:30 | 2055.14 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 17.00 | 0.00 | 01-JAN-00:15 | 2964.59 | 29-JUN-15:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 16.69 | 0.00 | 18-MAY-02:30 | 2354.84 | 28-JUN-16:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 2.65 | 0.00 | 01-JAN-10:30 | 1279.97 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 14.04 | 0.00 | 01-JAN-00:15 | 2354.84 | 28-JUN-16:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 16.75 | 0.03 | 30-OCT-21:30 | 2349.09 | 29-JUN-15:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 2.67 | 0.00 | 01-JAN-10:15 | 1285.43 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 14.08 | 0.00 | 01-JAN-00:15 | 2349.09 | 29-JUN-15:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 21.74 | 0.01 | 19-NOV-07:00 | 2811.64 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 1.01 | 0.00 | 01-JAN-00:15 | 1109.16 | 18-JAN-02:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 20.73 | 0.00 | 01-JAN-03:00 | 2811.64 | 03-SEP-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 21.80 | 0.00 | 15-JAN-01:00 | 2819.82 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 1.02 | 0.00 | 01-JAN-00:15 | 1109.71 | 18-JAN-02:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 20.78 | 0.00 | 01-JAN-03:00 | 2819.82 | 03-SEP-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 697.00 | 0.00 | 16-APR-06:00 | 83949.43 | 21-JUL-17:15 |
HeatingCoils:EnergyTransfer | 63.49 | 0.00 | 01-JAN-12:30 | 34142.88 | 18-JAN-01:15 |
CoolingCoils:EnergyTransfer | 633.52 | 0.00 | 01-JAN-00:15 | 83949.43 | 21-JUL-17:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.794 | -11.184 | 0.000 | 0.000 | 3.751 | 2.413 | 12.213 | 18.684 | 0.000 | 0.198 | 0.000 | 0.000 | -6.427 | 0.000 | -2.941 | -17.501 |
G NW APARTMENT | 2.186 | -8.024 | 0.000 | 0.000 | 3.797 | 2.413 | 12.213 | 9.420 | 0.000 | 0.195 | 0.000 | 0.000 | -6.532 | 0.000 | -2.814 | -12.853 |
OFFICE | 0.259 | -25.115 | 0.000 | 0.000 | 0.518 | 21.914 | 7.534 | 19.256 | 0.000 | 0.187 | 0.000 | 0.000 | -6.224 | 0.000 | -2.177 | -16.151 |
G NE APARTMENT | 1.962 | -8.597 | 0.000 | 0.000 | 3.809 | 2.413 | 12.213 | 9.796 | 0.000 | 0.195 | 0.000 | 0.000 | -6.225 | 0.000 | -2.799 | -12.767 |
G N1 APARTMENT | 0.754 | -7.059 | 0.000 | 0.000 | 3.812 | 2.413 | 12.213 | 3.135 | 0.000 | 0.130 | 0.000 | 0.000 | -4.010 | 0.000 | -1.918 | -9.469 |
G N2 APARTMENT | 0.752 | -7.074 | 0.000 | 0.000 | 3.813 | 2.413 | 12.213 | 3.133 | 0.000 | 0.130 | 0.000 | 0.000 | -4.008 | 0.000 | -1.918 | -9.453 |
G S1 APARTMENT | 0.130 | -10.513 | 0.000 | 0.000 | 3.755 | 2.413 | 12.213 | 12.496 | 0.000 | 0.132 | 0.000 | 0.000 | -3.886 | 0.000 | -2.052 | -14.688 |
G S2 APARTMENT | 0.151 | -10.274 | 0.000 | 0.000 | 3.756 | 2.413 | 12.213 | 12.498 | 0.000 | 0.132 | 0.001 | 0.000 | -3.879 | 0.000 | -2.053 | -14.956 |
M SW APARTMENT | 0.068 | -51.676 | 0.000 | 0.000 | 3.586 | 2.413 | 12.213 | 18.133 | 0.000 | 0.278 | 26.484 | 0.000 | -7.201 | 0.000 | -4.297 | 0.000 |
M NW APARTMENT | 0.853 | -35.041 | 0.000 | 0.000 | 3.668 | 2.413 | 12.213 | 8.981 | 0.000 | 0.275 | 18.018 | 0.000 | -7.232 | 0.000 | -4.149 | -0.000 |
M SE APARTMENT | 0.085 | -53.527 | 0.000 | 0.000 | 3.595 | 2.413 | 12.213 | 18.636 | 0.000 | 0.278 | 27.611 | 0.000 | -7.014 | 0.000 | -4.290 | 0.000 |
M NE APARTMENT | 0.913 | -37.249 | 0.000 | 0.000 | 3.684 | 2.413 | 12.213 | 9.336 | 0.000 | 0.275 | 19.419 | 0.000 | -6.876 | 0.000 | -4.129 | -0.001 |
M N1 APARTMENT | 0.070 | -32.658 | 0.000 | 0.000 | 3.657 | 2.413 | 12.213 | 2.873 | 0.000 | 0.181 | 18.635 | 0.000 | -4.521 | 0.000 | -2.863 | 0.000 |
M N2 APARTMENT | 0.079 | -32.698 | 0.000 | 0.000 | 3.658 | 2.413 | 12.213 | 2.873 | 0.000 | 0.181 | 18.660 | 0.000 | -4.517 | 0.000 | -2.862 | 0.000 |
M S1 APARTMENT | 0.000 | -50.031 | 0.000 | 0.000 | 3.560 | 2.413 | 12.213 | 12.142 | 0.000 | 0.184 | 26.880 | 0.000 | -4.385 | 0.000 | -2.977 | 0.000 |
M S2 APARTMENT | 0.000 | -50.075 | 0.000 | 0.000 | 3.561 | 2.413 | 12.213 | 12.142 | 0.000 | 0.184 | 26.922 | 0.000 | -4.384 | 0.000 | -2.976 | 0.000 |
T SW APARTMENT | 2.770 | -22.733 | 0.000 | 0.000 | 3.692 | 2.413 | 12.213 | 18.019 | 0.000 | 0.376 | 0.000 | 0.000 | -6.703 | 0.000 | -5.351 | -4.696 |
T NW APARTMENT | 5.076 | -16.424 | 0.000 | 0.000 | 3.737 | 2.413 | 12.213 | 8.886 | 0.000 | 0.370 | 0.000 | 0.000 | -6.784 | 0.000 | -5.197 | -4.291 |
T SE APARTMENT | 2.675 | -23.344 | 0.000 | 0.000 | 3.699 | 2.413 | 12.213 | 18.526 | 0.000 | 0.376 | 0.000 | 0.000 | -6.542 | 0.000 | -5.351 | -4.665 |
T NE APARTMENT | 4.748 | -17.003 | 0.000 | 0.000 | 3.751 | 2.413 | 12.213 | 9.280 | 0.000 | 0.370 | 0.000 | 0.000 | -6.485 | 0.000 | -5.181 | -4.105 |
T N1 APARTMENT | 2.647 | -14.041 | 0.000 | 0.000 | 3.742 | 2.413 | 12.213 | 2.862 | 0.000 | 0.247 | 0.000 | 0.000 | -4.196 | 0.000 | -3.517 | -2.371 |
T N2 APARTMENT | 2.665 | -14.083 | 0.000 | 0.000 | 3.743 | 2.413 | 12.213 | 2.859 | 0.000 | 0.247 | 0.000 | 0.000 | -4.193 | 0.000 | -3.517 | -2.348 |
T S1 APARTMENT | 1.011 | -20.729 | 0.000 | 0.000 | 3.679 | 2.413 | 12.213 | 12.093 | 0.000 | 0.253 | 0.000 | 0.000 | -4.088 | 0.000 | -3.657 | -3.188 |
T S2 APARTMENT | 1.019 | -20.781 | 0.000 | 0.000 | 3.680 | 2.413 | 12.213 | 12.090 | 0.000 | 0.253 | 0.000 | 0.000 | -4.086 | 0.000 | -3.657 | -3.143 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.174 | 0.000 | 0.020 | 0.000 | 0.000 | -0.762 | 0.000 | -0.827 | -15.675 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 0.620 | 0.000 | 0.750 | 0.000 | 0.000 | -1.982 | 0.000 | -14.641 | -8.081 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.177 | 0.000 | 0.019 | 0.000 | 0.000 | -0.854 | 0.000 | -0.688 | -15.724 |
Total Facility | 31.667 | -579.935 | 0.000 | 0.000 | 85.705 | 128.627 | 294.692 | 259.121 | 0.000 | 6.415 | 182.631 | 0.000 | -133.995 | 0.000 | -98.801 | -176.127 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 21-JUL-17:06 | 0.00 | -2130.85 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 2121.88 | 0.00 | 71.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -987.05 |
G NW APARTMENT | 04-JUL-17:23 | 0.00 | -2119.52 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 2243.83 | 0.00 | 140.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1189.93 |
OFFICE | 21-SEP-13:30 | 0.00 | -3442.15 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 2187.09 | 0.00 | 22.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1002.35 |
G NE APARTMENT | 04-JUL-17:08 | 0.00 | -1507.13 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 748.60 | 0.00 | 157.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -324.14 |
G N1 APARTMENT | 04-JUL-18:15 | 0.00 | -1206.91 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 628.00 | 0.00 | 60.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -401.57 |
G N2 APARTMENT | 04-JUL-18:15 | 0.00 | -1193.56 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 628.21 | 0.00 | 60.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -415.13 |
G S1 APARTMENT | 21-SEP-13:30 | 0.00 | -1420.66 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1936.85 | 0.00 | 12.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -981.06 |
G S2 APARTMENT | 21-SEP-13:30 | 0.00 | -1408.27 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1937.03 | 0.00 | 12.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -993.63 |
M SW APARTMENT | 20-SEP-16:10 | 0.00 | -5709.91 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2383.44 | 0.00 | 34.72 | 2474.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 04-JUL-17:23 | 0.00 | -5518.19 | 0.00 | 0.00 | 141.80 | 194.45 | 588.62 | 2228.06 | 0.00 | 201.88 | 2163.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 21-SEP-13:30 | 0.00 | -4761.86 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2162.42 | 0.00 | 30.17 | 2117.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 04-JUL-17:08 | 0.00 | -4201.61 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 739.73 | 0.00 | 226.36 | 2310.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 04-JUL-18:15 | 0.00 | -3288.56 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 619.66 | 0.00 | 87.17 | 1662.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 04-JUL-18:15 | 0.00 | -3266.60 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 619.79 | 0.00 | 87.17 | 1639.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 11-OCT-12:45 | 0.00 | -4132.29 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2063.35 | 0.00 | 259.61 | 1351.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 11-OCT-12:45 | 0.00 | -4138.61 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 2063.31 | 0.00 | 259.62 | 1357.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 21-JUL-16:23 | 0.00 | -3725.70 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2207.44 | 0.00 | 162.27 | 538.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 28-JUN-16:23 | 0.00 | -3696.40 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2348.21 | 0.00 | 139.00 | 391.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 03-SEP-13:30 | 0.00 | -3332.28 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2138.08 | 0.00 | 88.68 | 653.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 29-JUN-15:15 | 0.00 | -2963.84 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 990.43 | 0.00 | 267.51 | 1085.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 28-JUN-16:23 | 0.00 | -2354.70 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 511.23 | 0.00 | 83.84 | 942.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-JUN-15:15 | 0.00 | -2348.51 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 604.52 | 0.00 | 161.36 | 962.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 03-SEP-13:30 | 0.00 | -2811.65 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1786.99 | 0.00 | 53.49 | 519.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 03-SEP-13:30 | 0.00 | -2819.83 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1786.86 | 0.00 | 53.49 | 527.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 04-JUL-17:08 | 0.00 | -65892.68 | 0.00 | 0.00 | 3261.56 | 6475.86 | 14071.03 | 21752.31 | 0.00 | 4748.75 | 15583.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 16-JAN-07:01 | 1638.61 | 0.00 | 0.00 | 0.00 | 163.25 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -488.85 | 0.00 | -162.39 | -1626.85 |
G NW APARTMENT | 14-DEC-04:00 | 995.60 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -642.36 | 0.00 | -653.32 | -127.67 |
OFFICE | 11-JAN-07:01 | 3426.25 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -548.84 | 0.00 | -266.90 | -3185.08 |
G NE APARTMENT | 17-NOV-07:01 | 1026.05 | 0.00 | 0.00 | 0.00 | 161.40 | 93.63 | 382.60 | 497.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -16.39 | -2144.56 |
G N1 APARTMENT | 01-MAR-07:01 | 1078.19 | 0.00 | 0.00 | 0.00 | 161.39 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -226.42 | 0.00 | -56.05 | -1433.34 |
G N2 APARTMENT | 22-FEB-07:01 | 1070.60 | 0.00 | 0.00 | 0.00 | 161.38 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -294.16 | 0.00 | -79.10 | -1334.96 |
G S1 APARTMENT | 20-JAN-07:10 | 831.96 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -385.52 | 0.00 | -11.53 | -1072.35 |
G S2 APARTMENT | 10-DEC-07:01 | 1004.71 | 0.00 | 0.00 | 0.00 | 161.41 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -371.83 | 0.00 | -58.31 | -1212.22 |
M SW APARTMENT | 18-JAN-01:15 | 1222.99 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -664.63 | 0.00 | -619.49 | -384.28 |
M NW APARTMENT | 14-DEC-04:00 | 1816.10 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -669.72 | 0.00 | -939.69 | -634.44 |
M SE APARTMENT | 18-JAN-01:15 | 1284.43 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -673.65 | 0.00 | -619.49 | -436.71 |
M NE APARTMENT | 14-DEC-04:00 | 1951.69 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -656.86 | 0.00 | -939.69 | -782.89 |
M N1 APARTMENT | 04-FEB-07:15 | 1654.36 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -445.08 | 0.00 | -223.36 | -1623.37 |
M N2 APARTMENT | 22-DEC-06:08 | 1365.10 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -444.79 | 0.00 | -183.65 | -1345.02 |
M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 17-JAN-04:00 | 1750.21 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -653.88 | 0.00 | -827.61 | -696.48 |
T NW APARTMENT | 14-DEC-04:00 | 2006.75 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -643.92 | 0.00 | -1245.08 | -545.50 |
T SE APARTMENT | 17-JAN-04:00 | 1765.68 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -665.03 | 0.00 | -827.61 | -700.80 |
T NE APARTMENT | 14-DEC-04:00 | 2054.80 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -632.78 | 0.00 | -1245.08 | -604.70 |
T N1 APARTMENT | 14-DEC-04:00 | 1279.79 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -390.05 | 0.00 | -751.03 | -566.46 |
T N2 APARTMENT | 14-DEC-04:00 | 1285.25 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -389.95 | 0.00 | -751.03 | -572.03 |
T S1 APARTMENT | 02-DEC-07:01 | 1431.87 | 0.00 | 0.00 | 0.00 | 162.66 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -329.86 | 0.00 | -83.97 | -1656.93 |
T S2 APARTMENT | 25-MAR-06:01 | 1692.66 | 0.00 | 0.00 | 0.00 | 162.95 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -349.40 | 0.00 | -164.70 | -1817.73 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 18-JAN-01:15 | 22198.29 | 0.00 | 0.00 | 0.00 | 4362.43 | 2334.74 | 5719.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12826.04 | 0.00 | -12282.44 | -9506.79 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Sec1.1A-General InformationData | |
Weather File | Albuquerque Intl Sunport NM USA TMY3 WMO#=723650 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 39.75 |
Number of hours cooling loads not met | 0.75 |
Number of hours not met | 40.50 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 79.36 | 42678.60 | 0.00 | 0.00 |
Space Cooling | 163.03 | 21666.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 255.34 | 8096.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 385.56 | 23202.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1519.76 | 79.36 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1519.76 |
Natural Gas | 0.00 | 79.36 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1599.12 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 52.01 |
Fans-Interior | 81.46 |
Service Water Heating | 123.00 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.57 |
Subtotal | 484.83 |
Natural Gas [MJ/m2] | |
Space Heating | 25.32 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 25.32 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 10.32 |
Space Heating | 4.96 |
Space Cooling | 10.19 |
Fans-Interior | 15.97 |
Service Water Heating | 24.11 |
Receptacle Equipment | 31.98 |
Miscellaneous | 2.46 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.205876 |
G NW APARTMENT DIRECT AIR | 0.205269 |
OFFICE DIRECT AIR | 0.514353 |
G NE APARTMENT DIRECT AIR | 0.151577 |
G N1 APARTMENT DIRECT AIR | 0.124026 |
G N2 APARTMENT DIRECT AIR | 0.122786 |
G S1 APARTMENT DIRECT AIR | 0.120549 |
G S2 APARTMENT DIRECT AIR | 0.122416 |
M SW APARTMENT DIRECT AIR | 0.548335 |
M NW APARTMENT DIRECT AIR | 0.543288 |
M SE APARTMENT DIRECT AIR | 0.451329 |
M NE APARTMENT DIRECT AIR | 0.423199 |
M N1 APARTMENT DIRECT AIR | 0.339221 |
M N2 APARTMENT DIRECT AIR | 0.337137 |
M S1 APARTMENT DIRECT AIR | 0.335133 |
M S2 APARTMENT DIRECT AIR | 0.333068 |
T SW APARTMENT DIRECT AIR | 0.371996 |
T NW APARTMENT DIRECT AIR | 0.362340 |
T SE APARTMENT DIRECT AIR | 0.328475 |
T NE APARTMENT DIRECT AIR | 0.293161 |
T N1 APARTMENT DIRECT AIR | 0.233783 |
T N2 APARTMENT DIRECT AIR | 0.231896 |
T S1 APARTMENT DIRECT AIR | 0.264364 |
T S2 APARTMENT DIRECT AIR | 0.265034 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.205876 |
SPLIT GNW MAIN BRANCH | 0.205269 |
SPLIT OFFICE MAIN BRANCH | 0.514353 |
SPLIT GNE MAIN BRANCH | 0.151577 |
SPLIT GN1 MAIN BRANCH | 0.124026 |
SPLIT GN2 MAIN BRANCH | 0.122786 |
SPLIT GS1 MAIN BRANCH | 0.120549 |
SPLIT GS2 MAIN BRANCH | 0.122416 |
SPLIT MSW MAIN BRANCH | 0.548335 |
SPLIT MNW MAIN BRANCH | 0.543288 |
SPLIT MSE MAIN BRANCH | 0.451329 |
SPLIT MNE MAIN BRANCH | 0.423199 |
SPLIT MN1 MAIN BRANCH | 0.339221 |
SPLIT MN2 MAIN BRANCH | 0.337137 |
SPLIT MS1 MAIN BRANCH | 0.335133 |
SPLIT MS2 MAIN BRANCH | 0.333068 |
SPLIT TSW MAIN BRANCH | 0.371996 |
SPLIT TNW MAIN BRANCH | 0.362340 |
SPLIT TSE MAIN BRANCH | 0.328475 |
SPLIT TNE MAIN BRANCH | 0.293161 |
SPLIT TN1 MAIN BRANCH | 0.233783 |
SPLIT TN2 MAIN BRANCH | 0.231896 |
SPLIT TS1 MAIN BRANCH | 0.264364 |
SPLIT TS2 MAIN BRANCH | 0.265034 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.205876 |
SPLIT GNW | 0.205269 |
SPLIT OFFICE | 0.514353 |
SPLIT GNE | 0.151577 |
SPLIT GN1 | 0.124026 |
SPLIT GN2 | 0.122786 |
SPLIT GS1 | 0.120549 |
SPLIT GS2 | 0.122416 |
SPLIT MSW | 0.548335 |
SPLIT MNW | 0.543288 |
SPLIT MSE | 0.451329 |
SPLIT MNE | 0.423199 |
SPLIT MN1 | 0.339221 |
SPLIT MN2 | 0.337137 |
SPLIT MS1 | 0.335133 |
SPLIT MS2 | 0.333068 |
SPLIT TSW | 0.371996 |
SPLIT TNW | 0.362340 |
SPLIT TSE | 0.328475 |
SPLIT TNE | 0.293161 |
SPLIT TN1 | 0.233783 |
SPLIT TN2 | 0.231896 |
SPLIT TS1 | 0.264364 |
SPLIT TS2 | 0.265034 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.205876 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.205269 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.514353 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.151577 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.124026 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.122786 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.120549 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.122416 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.548335 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.543288 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.451329 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.423199 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.339221 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.337137 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.335133 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.333068 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.371996 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.362340 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.328475 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.293161 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.233783 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.231896 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.264364 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.265034 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.205876 | 3407.97 | 0.798655 |
SPLIT GNW COOLING COIL | 0.205269 | 3397.93 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.514353 | 8514.37 | 0.798655 |
SPLIT GNE COOLING COIL | 0.151577 | 2509.14 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.124026 | 2053.06 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.122786 | 2032.55 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.120549 | 1995.51 | 0.798655 |
SPLIT GS2 COOLING COIL | 0.122416 | 2026.42 | 0.798655 |
SPLIT MSW COOLING COIL | 0.548335 | 9076.89 | 0.798655 |
SPLIT MNW COOLING COIL | 0.543288 | 8993.35 | 0.798655 |
SPLIT MSE COOLING COIL | 0.451329 | 7471.10 | 0.798655 |
SPLIT MNE COOLING COIL | 0.423199 | 7005.45 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.339221 | 5615.31 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.337137 | 5580.82 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.335133 | 5547.64 | 0.798655 |
SPLIT MS2 COOLING COIL | 0.333068 | 5513.46 | 0.798655 |
SPLIT TSW COOLING COIL | 0.371996 | 6157.85 | 0.798655 |
SPLIT TNW COOLING COIL | 0.362340 | 5998.02 | 0.798655 |
SPLIT TSE COOLING COIL | 0.328475 | 5437.43 | 0.798655 |
SPLIT TNE COOLING COIL | 0.293161 | 4852.86 | 0.798655 |
SPLIT TN1 COOLING COIL | 0.233783 | 3869.94 | 0.798655 |
SPLIT TN2 COOLING COIL | 0.231896 | 3838.70 | 0.798655 |
SPLIT TS1 COOLING COIL | 0.264364 | 4376.16 | 0.798655 |
SPLIT TS2 COOLING COIL | 0.265034 | 4387.26 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.205876 | 0.205876 | 0.205876 | 0.205876 | 1938.43 | 3407.97 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.205269 | 0.205269 | 0.205269 | 0.205269 | 1918.34 | 3397.93 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.514353 | 0.514353 | 0.514353 | 0.514353 | 3769.06 | 8514.37 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.151577 | 0.151577 | 0.151577 | 0.151577 | 1918.34 | 2509.14 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.124026 | 0.124026 | 0.124026 | 0.124026 | 1495.50 | 2053.06 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.122786 | 0.122786 | 0.122786 | 0.122786 | 1495.50 | 2032.55 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.120549 | 0.120549 | 0.120549 | 0.120549 | 1495.50 | 1995.51 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.122416 | 0.122416 | 0.122416 | 0.122416 | 1495.97 | 2026.42 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.548335 | 0.548335 | 0.548335 | 0.548335 | 3799.60 | 9076.89 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.543288 | 0.543288 | 0.543288 | 0.543288 | 3824.72 | 8993.35 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.451329 | 0.451329 | 0.451329 | 0.451329 | 3799.60 | 7471.10 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.423199 | 0.423199 | 0.423199 | 0.423199 | 3824.72 | 7005.45 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.339221 | 0.339221 | 0.339221 | 0.339221 | 2990.99 | 5615.31 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.337137 | 0.337137 | 0.337137 | 0.337137 | 2990.99 | 5580.82 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.335133 | 0.335133 | 0.335133 | 0.335133 | 2990.99 | 5547.64 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.333068 | 0.333068 | 0.333068 | 0.333068 | 2990.99 | 5513.46 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.371996 | 0.371996 | 0.371996 | 0.371996 | 3053.00 | 6157.85 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.362340 | 0.362340 | 0.362340 | 0.362340 | 3067.67 | 5998.02 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.328475 | 0.328475 | 0.328475 | 0.328475 | 3053.00 | 5437.43 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.293161 | 0.293161 | 0.293161 | 0.293161 | 3067.67 | 4852.86 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.233783 | 0.233783 | 0.233783 | 0.233783 | 2398.91 | 3869.94 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.231896 | 0.231896 | 0.231896 | 0.231896 | 2398.91 | 3838.70 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.264364 | 0.264364 | 0.264364 | 0.264364 | 2382.27 | 4376.16 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.265034 | 0.265034 | 0.265034 | 0.265034 | 2382.27 | 4387.26 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.205876 |
SPLIT GNW SUPPLY FAN | 0.205269 |
SPLIT OFFICE SUPPLY FAN | 0.514353 |
SPLIT GNE SUPPLY FAN | 0.151577 |
SPLIT GN1 SUPPLY FAN | 0.124026 |
SPLIT GN2 SUPPLY FAN | 0.122786 |
SPLIT GS1 SUPPLY FAN | 0.120549 |
SPLIT GS2 SUPPLY FAN | 0.122416 |
SPLIT MSW SUPPLY FAN | 0.548335 |
SPLIT MNW SUPPLY FAN | 0.543288 |
SPLIT MSE SUPPLY FAN | 0.451329 |
SPLIT MNE SUPPLY FAN | 0.423199 |
SPLIT MN1 SUPPLY FAN | 0.339221 |
SPLIT MN2 SUPPLY FAN | 0.337137 |
SPLIT MS1 SUPPLY FAN | 0.335133 |
SPLIT MS2 SUPPLY FAN | 0.333068 |
SPLIT TSW SUPPLY FAN | 0.371996 |
SPLIT TNW SUPPLY FAN | 0.362340 |
SPLIT TSE SUPPLY FAN | 0.328475 |
SPLIT TNE SUPPLY FAN | 0.293161 |
SPLIT TN1 SUPPLY FAN | 0.233783 |
SPLIT TN2 SUPPLY FAN | 0.231896 |
SPLIT TS1 SUPPLY FAN | 0.264364 |
SPLIT TS2 SUPPLY FAN | 0.265034 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1938.43 |
SPLIT GNW HEATING COIL | 1918.34 |
SPLIT OFFICE HEATING COIL | 3769.06 |
SPLIT GNE HEATING COIL | 1918.34 |
SPLIT GN1 HEATING COIL | 1495.50 |
SPLIT GN2 HEATING COIL | 1495.50 |
SPLIT GS1 HEATING COIL | 1495.50 |
SPLIT GS2 HEATING COIL | 1495.97 |
SPLIT MSW HEATING COIL | 3799.60 |
SPLIT MNW HEATING COIL | 3824.72 |
SPLIT MSE HEATING COIL | 3799.60 |
SPLIT MNE HEATING COIL | 3824.72 |
SPLIT MN1 HEATING COIL | 2990.99 |
SPLIT MN2 HEATING COIL | 2990.99 |
SPLIT MS1 HEATING COIL | 2990.99 |
SPLIT MS2 HEATING COIL | 2990.99 |
SPLIT TSW HEATING COIL | 3053.00 |
SPLIT TNW HEATING COIL | 3067.67 |
SPLIT TSE HEATING COIL | 3053.00 |
SPLIT TNE HEATING COIL | 3067.67 |
SPLIT TN1 HEATING COIL | 2398.91 |
SPLIT TN2 HEATING COIL | 2398.91 |
SPLIT TS1 HEATING COIL | 2382.27 |
SPLIT TS2 HEATING COIL | 2382.27 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:29
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.32 | 2.60 |
February | 22.46 | 4.29 |
March | 22.69 | 8.77 |
April | 23.41 | 13.91 |
May | 23.80 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.71 | 13.71 |
November | 22.85 | 6.96 |
December | 22.32 | 2.07 |
Annual Sum or Average | 23.43 | 13.68 |
Minimum of Months | 22.32 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | 2.60 |
February | 21.91 | 4.29 |
March | 22.23 | 8.77 |
April | 23.15 | 13.91 |
May | 23.77 | 17.82 |
June | 24.37 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.28 | 13.71 |
November | 22.06 | 6.96 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.13 | 13.68 |
Minimum of Months | 21.75 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.02 | 2.60 |
February | 22.33 | 4.29 |
March | 22.98 | 8.77 |
April | 23.61 | 13.91 |
May | 23.81 | 17.82 |
June | 23.90 | 23.21 |
July | 23.90 | 25.63 |
August | 23.90 | 24.08 |
September | 23.90 | 20.49 |
October | 23.66 | 13.71 |
November | 22.96 | 6.96 |
December | 22.07 | 2.07 |
Annual Sum or Average | 23.26 | 13.68 |
Minimum of Months | 22.02 | 2.07 |
Maximum of Months | 23.90 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | 2.60 |
February | 21.82 | 4.29 |
March | 22.15 | 8.77 |
April | 23.15 | 13.91 |
May | 23.75 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.20 | 13.71 |
November | 21.93 | 6.96 |
December | 21.70 | 2.07 |
Annual Sum or Average | 23.09 | 13.68 |
Minimum of Months | 21.70 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | 2.60 |
February | 21.81 | 4.29 |
March | 22.05 | 8.77 |
April | 22.89 | 13.91 |
May | 23.60 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.13 | 13.71 |
November | 21.95 | 6.96 |
December | 21.71 | 2.07 |
Annual Sum or Average | 23.04 | 13.68 |
Minimum of Months | 21.71 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | 2.60 |
February | 21.81 | 4.29 |
March | 22.05 | 8.77 |
April | 22.89 | 13.91 |
May | 23.60 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.13 | 13.71 |
November | 21.95 | 6.96 |
December | 21.71 | 2.07 |
Annual Sum or Average | 23.04 | 13.68 |
Minimum of Months | 21.71 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.36 | 2.60 |
February | 22.46 | 4.29 |
March | 22.63 | 8.77 |
April | 23.28 | 13.91 |
May | 23.67 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.73 | 13.71 |
November | 22.91 | 6.96 |
December | 22.37 | 2.07 |
Annual Sum or Average | 23.42 | 13.68 |
Minimum of Months | 22.36 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.35 | 2.60 |
February | 22.46 | 4.29 |
March | 22.64 | 8.77 |
April | 23.28 | 13.91 |
May | 23.67 | 17.82 |
June | 24.35 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.73 | 13.71 |
November | 22.91 | 6.96 |
December | 22.36 | 2.07 |
Annual Sum or Average | 23.42 | 13.68 |
Minimum of Months | 22.35 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.47 | 2.60 |
February | 23.70 | 4.29 |
March | 24.14 | 8.77 |
April | 24.36 | 13.91 |
May | 24.38 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.31 | 13.71 |
November | 24.17 | 6.96 |
December | 23.55 | 2.07 |
Annual Sum or Average | 24.14 | 13.68 |
Minimum of Months | 23.47 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.19 | 2.60 |
February | 22.68 | 4.29 |
March | 23.79 | 8.77 |
April | 24.32 | 13.91 |
May | 24.38 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.19 | 13.71 |
November | 23.52 | 6.96 |
December | 22.09 | 2.07 |
Annual Sum or Average | 23.73 | 13.68 |
Minimum of Months | 22.09 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.39 | 2.60 |
February | 23.62 | 4.29 |
March | 24.11 | 8.77 |
April | 24.35 | 13.91 |
May | 24.39 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.30 | 13.71 |
November | 24.12 | 6.96 |
December | 23.47 | 2.07 |
Annual Sum or Average | 24.11 | 13.68 |
Minimum of Months | 23.39 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.09 | 2.60 |
February | 22.49 | 4.29 |
March | 23.74 | 8.77 |
April | 24.31 | 13.91 |
May | 24.38 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.16 | 13.71 |
November | 23.35 | 6.96 |
December | 21.93 | 2.07 |
Annual Sum or Average | 23.68 | 13.68 |
Minimum of Months | 21.93 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.23 | 2.60 |
February | 22.75 | 4.29 |
March | 23.93 | 8.77 |
April | 24.34 | 13.91 |
May | 24.39 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.25 | 13.71 |
November | 23.68 | 6.96 |
December | 22.12 | 2.07 |
Annual Sum or Average | 23.78 | 13.68 |
Minimum of Months | 22.12 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.22 | 2.60 |
February | 22.73 | 4.29 |
March | 23.92 | 8.77 |
April | 24.34 | 13.91 |
May | 24.39 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.25 | 13.71 |
November | 23.66 | 6.96 |
December | 22.10 | 2.07 |
Annual Sum or Average | 23.77 | 13.68 |
Minimum of Months | 22.10 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.73 | 2.60 |
February | 23.97 | 4.29 |
March | 24.26 | 8.77 |
April | 24.38 | 13.91 |
May | 24.39 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.35 | 13.71 |
November | 24.29 | 6.96 |
December | 23.89 | 2.07 |
Annual Sum or Average | 24.24 | 13.68 |
Minimum of Months | 23.73 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.73 | 2.60 |
February | 23.96 | 4.29 |
March | 24.26 | 8.77 |
April | 24.38 | 13.91 |
May | 24.39 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.35 | 13.71 |
November | 24.29 | 6.96 |
December | 23.88 | 2.07 |
Annual Sum or Average | 24.24 | 13.68 |
Minimum of Months | 23.73 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.68 | 2.60 |
February | 22.89 | 4.29 |
March | 23.24 | 8.77 |
April | 23.97 | 13.91 |
May | 24.24 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.92 | 13.71 |
November | 23.25 | 6.96 |
December | 22.71 | 2.07 |
Annual Sum or Average | 23.71 | 13.68 |
Minimum of Months | 22.68 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.07 | 2.60 |
February | 22.35 | 4.29 |
March | 22.93 | 8.77 |
April | 23.86 | 13.91 |
May | 24.23 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.70 | 13.71 |
November | 22.62 | 6.96 |
December | 21.93 | 2.07 |
Annual Sum or Average | 23.44 | 13.68 |
Minimum of Months | 21.93 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.66 | 2.60 |
February | 22.89 | 4.29 |
March | 23.25 | 8.77 |
April | 23.98 | 13.91 |
May | 24.25 | 17.82 |
June | 24.37 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.91 | 13.71 |
November | 23.24 | 6.96 |
December | 22.72 | 2.07 |
Annual Sum or Average | 23.71 | 13.68 |
Minimum of Months | 22.66 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.96 | 2.60 |
February | 22.26 | 4.29 |
March | 22.94 | 8.77 |
April | 23.88 | 13.91 |
May | 24.22 | 17.82 |
June | 24.37 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.38 | 20.49 |
October | 23.68 | 13.71 |
November | 22.49 | 6.96 |
December | 21.80 | 2.07 |
Annual Sum or Average | 23.40 | 13.68 |
Minimum of Months | 21.80 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | 2.60 |
February | 22.24 | 4.29 |
March | 22.92 | 8.77 |
April | 23.87 | 13.91 |
May | 24.24 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.70 | 13.71 |
November | 22.50 | 6.96 |
December | 21.81 | 2.07 |
Annual Sum or Average | 23.40 | 13.68 |
Minimum of Months | 21.81 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | 2.60 |
February | 22.24 | 4.29 |
March | 22.92 | 8.77 |
April | 23.87 | 13.91 |
May | 24.24 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.70 | 13.71 |
November | 22.49 | 6.96 |
December | 21.80 | 2.07 |
Annual Sum or Average | 23.40 | 13.68 |
Minimum of Months | 21.80 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 2.60 |
February | 22.98 | 4.29 |
March | 23.36 | 8.77 |
April | 24.03 | 13.91 |
May | 24.27 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.99 | 13.71 |
November | 23.36 | 6.96 |
December | 22.81 | 2.07 |
Annual Sum or Average | 23.77 | 13.68 |
Minimum of Months | 22.76 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 2.60 |
February | 22.98 | 4.29 |
March | 23.36 | 8.77 |
April | 24.03 | 13.91 |
May | 24.27 | 17.82 |
June | 24.38 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.99 | 13.71 |
November | 23.36 | 6.96 |
December | 22.81 | 2.07 |
Annual Sum or Average | 23.77 | 13.68 |
Minimum of Months | 22.76 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.51 | 2.60 |
February | 23.02 | 4.29 |
March | 24.02 | 8.77 |
April | 25.44 | 13.91 |
May | 26.14 | 17.82 |
June | 26.88 | 23.21 |
July | 27.23 | 25.63 |
August | 27.12 | 24.08 |
September | 26.63 | 20.49 |
October | 25.26 | 13.71 |
November | 23.60 | 6.96 |
December | 22.40 | 2.07 |
Annual Sum or Average | 25.03 | 13.68 |
Minimum of Months | 22.40 | 2.07 |
Maximum of Months | 27.23 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.06 | 2.60 |
February | 21.41 | 4.29 |
March | 22.26 | 8.77 |
April | 23.41 | 13.91 |
May | 24.22 | 17.82 |
June | 26.20 | 23.21 |
July | 26.72 | 25.63 |
August | 26.56 | 24.08 |
September | 26.08 | 20.49 |
October | 23.80 | 13.71 |
November | 22.09 | 6.96 |
December | 21.00 | 2.07 |
Annual Sum or Average | 23.74 | 13.68 |
Minimum of Months | 21.00 | 2.07 |
Maximum of Months | 26.72 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:29
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.69 | 2.60 |
February | 25.10 | 4.29 |
March | 26.01 | 8.77 |
April | 26.63 | 13.91 |
May | 26.79 | 17.82 |
June | 27.05 | 23.21 |
July | 27.17 | 25.63 |
August | 27.14 | 24.08 |
September | 26.99 | 20.49 |
October | 26.57 | 13.71 |
November | 25.88 | 6.96 |
December | 24.68 | 2.07 |
Annual Sum or Average | 26.23 | 13.68 |
Minimum of Months | 24.68 | 2.07 |
Maximum of Months | 27.17 | 25.63 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:29
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.121780E+12 | 77947.251 | 01-JAN-18:15 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 1952.177 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30360.731 | 0.000 | 0.000 | 0.000 |
February | 0.110571E+12 | 76538.522 | 13-FEB-18:30 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 4625.361 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26278.819 | 0.000 | 0.000 | 0.000 |
March | 0.122817E+12 | 76883.433 | 07-MAR-18:00 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 4573.492 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26675.599 | 0.000 | 0.000 | 0.000 |
April | 0.122772E+12 | 79063.449 | 13-APR-17:45 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 12626.408 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23311.028 | 0.000 | 0.000 | 0.000 |
May | 0.129156E+12 | 85666.575 | 15-MAY-17:45 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 15471.399 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27069.163 | 0.000 | 0.000 | 0.000 |
June | 0.133879E+12 | 85738.739 | 28-JUN-17:15 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 23234.149 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19378.577 | 0.000 | 0.000 | 0.000 |
July | 0.144076E+12 | 85971.598 | 21-JUL-17:30 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 23571.567 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19274.018 | 0.000 | 0.000 | 0.000 |
August | 0.141423E+12 | 87995.807 | 20-AUG-17:30 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 21666.844 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23202.951 | 0.000 | 0.000 | 0.000 |
September | 0.130392E+12 | 83719.169 | 02-SEP-17:45 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 17314.244 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23278.912 | 0.000 | 0.000 | 0.000 |
October | 0.125748E+12 | 81282.467 | 05-OCT-17:45 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 12302.018 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23346.107 | 0.000 | 0.000 | 0.000 |
November | 0.116763E+12 | 73748.722 | 30-NOV-18:45 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 1448.687 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26665.692 | 0.000 | 0.000 | 0.000 |
December | 0.120386E+12 | 75394.089 | 17-DEC-18:15 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 1664.582 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28095.164 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.151976E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.110571E+12 | 73748.722 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 1448.687 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19274.018 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.144076E+12 | 87995.807 | 8572.775 | 26456.413 | 8096.825 | 0.000 | 23571.567 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30360.731 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:29
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.245242E+11 | 42678.597 | 18-JAN-01:15 | 42678.597 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 42678.597 |
February | 0.163179E+11 | 41162.252 | 06-FEB-04:00 | 41162.252 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 41162.252 |
March | 0.525124E+10 | 20037.465 | 04-MAR-04:00 | 20037.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20037.465 |
April | 0.616234E+09 | 8970.924 | 08-APR-02:00 | 8970.924 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8970.924 |
May | 0.775585E+08 | 2847.439 | 05-MAY-04:00 | 2847.439 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 2847.439 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.156829E+10 | 18418.290 | 26-OCT-03:00 | 18418.290 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18418.290 |
November | 0.664624E+10 | 21795.054 | 28-NOV-04:00 | 21795.054 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21795.054 |
December | 0.243555E+11 | 36248.454 | 22-DEC-06:00 | 36248.454 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 36248.454 |
Annual Sum or Average | 0.793572E+11 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.245242E+11 | 42678.597 | 42678.597 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 42678.597 |