Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930

Simulation Timestamp: 2018-10-19 09:20:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1546.64 493.41 547.68
Net Site Energy 1546.64 493.41 547.68
Total Source Energy 4592.08 1464.96 1626.10
Net Source Energy 4592.08 1464.96 1626.10


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 146.96 0.00 0.00 0.00 0.00
Cooling 66.74 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.36 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 211.94 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 405.21 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1399.68 146.96 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 146.96 0.00 0.00 0.00 0.00
Cooling General 66.74 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.36 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 211.94 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 405.21 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.37 0.00 0.00 0.00 0.00 0.00
HVAC 242.17 52.04 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 495.64 52.04 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.20 0.00 0.00 0.00 0.00 0.00
HVAC 218.17 46.88 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 446.52 46.88 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1399.68 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1399.68 100.00
     
Total On-Site and Utility Electric Sources 1399.68 100.00
Total Electricity End Uses 1399.68 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 86.25
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 544.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
Weather File Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
Latitude [deg] 47.47
Longitude [deg] -122.3
Elevation [m] 122.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 10-AUG-17:30 19-FEB-05:00 - - - 01-JAN-07:30
Heating 0.00 52217.55 0.00 0.00 0.00 0.00
Cooling 18773.17 0.00 0.00 0.00 0.00 0.00
Interior Lighting 8572.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 6720.50 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 22922.71 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 83445.56 52217.55 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 52217.55 0.00 0.00 0.00 0.00
Cooling General 18773.17 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7168.38 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1404.40 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 6720.50 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 22922.71 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 159.30 0.00 0.00 0.00
Cooling 211.38 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 124.67 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 671.21 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1283.29 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4432.77 159.30 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 56.41 0.00 0.00 0.00
Cooling 74.85 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.15 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 237.68 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 454.43 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1569.69 56.41 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 56.41 0.00 0.00 0.00
Cooling 74.85 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.15 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 237.68 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 454.43 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1569.69 56.41 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB -4.20 0.00 -4.20 Wetbulb [C] 4.30 20.00
SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 29.40 10.40 18.30 Wetbulb [C] 4.20 350.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.52_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.60 83.60 39.36
Exterior Lighting Total 2508.33           39.36



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   2933.70 2343.01 590.68 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   2343.80 1871.89 471.91 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   7400.08 5910.11 1489.97 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   1591.15 1270.78 320.37 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1310.18 1046.38 263.80 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1291.91 1031.79 260.12 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2199.69 1741.72 457.97 0.79 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2242.82 1779.51 463.31 0.79 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   8135.17 6497.20 1637.97 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   6474.61 5170.98 1303.63 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7554.64 6033.55 1521.09 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   4829.24 3856.90 972.34 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3836.37 3063.94 772.43 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3803.61 3037.77 765.84 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6134.31 4899.20 1235.11 0.80 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6155.14 4915.84 1239.31 0.80 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5339.45 4264.38 1075.07 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   4149.30 3313.86 835.44 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5005.58 3997.73 1007.85 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   3101.11 2476.72 624.39 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2480.99 1975.38 505.62 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2482.64 1974.08 508.55 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4311.50 3443.40 868.10 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4325.15 3454.30 870.85 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 2794.8 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2232.8 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 7049.7 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 1515.8 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1248.2 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1230.8 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2097.5 3.14 10.71 11.13 10.44
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2138.1 3.14 10.70 11.12 10.42
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 7750.0 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 6168.1 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7197.0 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4600.6 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3654.8 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3623.5 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5843.9 3.13 10.67 11.09 10.38
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5863.7 3.13 10.67 11.09 10.38
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5086.7 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3952.9 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 4768.6 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2954.3 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2364.3 3.13 10.69 11.10 10.40
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2366.2 3.13 10.69 11.11 10.41
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4107.4 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4120.4 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   1948.11 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   1926.74 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   3758.68 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   1931.71 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1677.79 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1677.79 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1677.79 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   1677.79 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   3796.14 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   3819.21 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   3809.50 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   3832.56 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   3355.59 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   3355.59 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   3355.59 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   3355.59 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   2977.80 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   2991.27 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   2984.71 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   2998.18 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   2317.43 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   2317.63 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   2301.88 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   2302.08 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.51 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 158.59 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.45 500.73 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 107.67 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.08 88.65 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.08 87.42 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 146.07 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 149.60 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.49 550.47 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.39 438.11 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.46 511.19 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 326.77 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 259.59 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 257.37 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.37 415.08 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.37 416.49 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 361.30 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 280.77 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 338.71 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 209.84 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 166.76 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 166.39 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 291.74 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 292.66 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1859.05 2230.86 0.148 0.177 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 28.57 0.00879
G NW APARTMENT 1485.25 1782.30 0.118 0.142 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 26.90 0.00879
OFFICE 4595.79 5514.95 0.373 0.447 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 09:00:00 23.68 0.00879
G NE APARTMENT 1008.26 1209.91 0.080 0.096 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 09:45:00 25.01 0.00879
G N1 APARTMENT 830.25 996.30 0.066 0.079 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 25.34 0.00879
G N2 APARTMENT 818.67 982.41 0.065 0.078 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 25.34 0.00879
G S1 APARTMENT 1367.94 1641.53 0.109 0.130 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 29.27 0.00879
G S2 APARTMENT 1401.04 1681.25 0.111 0.134 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 29.14 0.00879
M SW APARTMENT 5155.17 6186.21 0.410 0.491 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 28.36 0.00879
M NW APARTMENT 4102.92 4923.50 0.326 0.391 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 26.90 0.00879
M SE APARTMENT 4787.29 5744.75 0.380 0.456 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 29.14 0.00879
M NE APARTMENT 3060.20 3672.24 0.243 0.292 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 25.84 0.00879
M N1 APARTMENT 2431.08 2917.30 0.193 0.232 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 25.34 0.00879
M N2 APARTMENT 2410.32 2892.38 0.191 0.230 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 25.34 0.00879
M S1 APARTMENT 3887.26 4664.71 0.309 0.371 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 29.27 0.00879
M S2 APARTMENT 3900.46 4680.55 0.310 0.372 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 29.27 0.00879
T SW APARTMENT 3383.54 4060.24 0.269 0.323 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:30:00 29.09 0.00879
T NW APARTMENT 2629.37 3155.25 0.209 0.251 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 27.42 0.00879
T SE APARTMENT 3171.97 3806.36 0.252 0.302 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 29.27 0.00879
T NE APARTMENT 1965.13 2358.15 0.156 0.187 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 29.40 0.00879
T N1 APARTMENT 1561.69 1874.03 0.124 0.149 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:30:00 29.09 0.00879
T N2 APARTMENT 1558.24 1869.89 0.124 0.149 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 29.24 0.00879
T S1 APARTMENT 2732.15 3278.58 0.217 0.260 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 29.40 0.00879
T S2 APARTMENT 2740.80 3288.96 0.218 0.261 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 29.40 0.00879


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 944.76 1133.71 0.028 0.033 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
G NW APARTMENT 951.38 1141.66 0.028 0.033 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
OFFICE 2236.08 2683.29 0.063 0.075 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -4.20 0.00269
G NE APARTMENT 955.58 1146.70 0.028 0.033 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
G N1 APARTMENT 531.04 637.25 0.016 0.026 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
G N2 APARTMENT 531.14 637.37 0.016 0.026 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
G S1 APARTMENT 525.58 630.70 0.015 0.026 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
G S2 APARTMENT 605.13 726.16 0.018 0.026 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M SW APARTMENT 1854.30 2225.16 0.054 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M NW APARTMENT 1873.81 2248.57 0.055 0.066 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M SE APARTMENT 1865.60 2238.72 0.054 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M NE APARTMENT 1885.10 2262.12 0.055 0.066 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M N1 APARTMENT 806.60 967.92 0.024 0.052 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M N2 APARTMENT 806.91 968.29 0.024 0.052 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M S1 APARTMENT 788.36 946.03 0.023 0.052 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
M S2 APARTMENT 788.67 946.40 0.023 0.052 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T SW APARTMENT 1840.25 2208.30 0.054 0.064 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T NW APARTMENT 1851.64 2221.96 0.054 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T SE APARTMENT 1846.09 2215.31 0.054 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T NE APARTMENT 1857.48 2228.98 0.054 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T N1 APARTMENT 1281.78 1538.13 0.037 0.045 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T N2 APARTMENT 1281.94 1538.33 0.037 0.045 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T S1 APARTMENT 1268.63 1522.35 0.037 0.044 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269
T S2 APARTMENT 1268.80 1522.55 0.037 0.044 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -4.20 0.00269


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.18 0.18 0.03 0.03
SPLIT GNW 0.14 0.14 0.03 0.03
SPLIT OFFICE 0.45 0.45 0.08 0.08
SPLIT GNE 0.10 0.10 0.03 0.03
SPLIT GN1 0.08 0.08 0.03 0.03
SPLIT GN2 0.08 0.08 0.03 0.03
SPLIT GS1 0.13 0.13 0.03 0.03
SPLIT GS2 0.13 0.13 0.03 0.03
SPLIT MSW 0.49 0.49 0.06 0.06
SPLIT MNW 0.39 0.39 0.07 0.07
SPLIT MSE 0.46 0.46 0.07 0.07
SPLIT MNE 0.29 0.29 0.07 0.07
SPLIT MN1 0.23 0.23 0.05 0.05
SPLIT MN2 0.23 0.23 0.05 0.05
SPLIT MS1 0.37 0.37 0.05 0.05
SPLIT MS2 0.37 0.37 0.05 0.05
SPLIT TSW 0.32 0.32 0.06 0.06
SPLIT TNW 0.25 0.25 0.06 0.06
SPLIT TSE 0.30 0.30 0.06 0.06
SPLIT TNE 0.19 0.19 0.07 0.07
SPLIT TN1 0.15 0.15 0.04 0.04
SPLIT TN2 0.15 0.15 0.04 0.04
SPLIT TS1 0.26 0.26 0.04 0.04
SPLIT TS2 0.26 0.26 0.04 0.04



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 1180.00 6217.50 70.25
G NW APARTMENT 886.25 6637.75 156.25
OFFICE 130.25 1722.00 18.25
G NE APARTMENT 842.75 6764.00 147.75
G N1 APARTMENT 505.25 6803.50 18.50
G N2 APARTMENT 502.75 6813.25 18.25
G S1 APARTMENT 961.00 6187.25 0.00
G S2 APARTMENT 922.00 6220.75 3.50
M SW APARTMENT 2678.00 3801.50 0.00
M NW APARTMENT 2151.50 4653.50 0.00
M SE APARTMENT 2673.50 3838.25 0.00
M NE APARTMENT 2130.00 4767.75 0.00
M N1 APARTMENT 2003.75 4346.00 0.00
M N2 APARTMENT 1991.75 4358.50 0.00
M S1 APARTMENT 2659.00 3180.50 0.00
M S2 APARTMENT 2659.50 3185.00 0.00
T SW APARTMENT 2289.75 5188.50 302.50
T NW APARTMENT 2140.50 5840.75 513.25
T SE APARTMENT 2304.25 5222.00 305.25
T NE APARTMENT 2115.00 5990.00 503.50
T N1 APARTMENT 1744.00 5852.50 225.75
T N2 APARTMENT 1739.00 5864.00 226.00
T S1 APARTMENT 2082.75 4928.00 108.00
T S2 APARTMENT 2079.00 4932.25 108.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 3589.00 7056.00 544.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 10.75 0.00 10.75 0.00
G NW APARTMENT 12.75 0.00 12.75 0.00
OFFICE 2.00 0.00 0.00 0.00
G NE APARTMENT 12.25 0.00 12.25 0.00
G N1 APARTMENT 4.75 0.00 4.75 0.00
G N2 APARTMENT 5.25 0.00 5.25 0.00
G S1 APARTMENT 8.00 0.00 8.00 0.00
G S2 APARTMENT 7.25 0.00 7.25 0.00
M SW APARTMENT 0.75 0.00 0.75 0.00
M NW APARTMENT 2.50 0.00 2.50 0.00
M SE APARTMENT 1.00 0.00 1.00 0.00
M NE APARTMENT 6.00 0.00 6.00 0.00
M N1 APARTMENT 0.25 0.00 0.25 0.00
M N2 APARTMENT 0.25 0.00 0.25 0.00
M S1 APARTMENT 1.25 0.00 1.25 0.00
M S2 APARTMENT 1.25 0.00 1.25 0.00
T SW APARTMENT 0.00 0.00 0.00 0.00
T NW APARTMENT 0.00 0.00 0.00 0.00
T SE APARTMENT 0.25 0.00 0.25 0.00
T NE APARTMENT 0.25 0.00 0.25 0.00
T N1 APARTMENT 13.00 0.00 13.00 0.00
T N2 APARTMENT 12.75 0.00 12.75 0.00
T S1 APARTMENT 1.25 0.00 1.25 0.00
T S2 APARTMENT 1.50 0.00 1.50 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 88.25 0.00 86.25 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.366 0.094 0.000 0.067
G NW APARTMENT 1.71 2.50 268.97 0.353 0.094 0.000 0.066
OFFICE 0.94 1.00 268.97 0.520 0.100 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.353 0.094 0.000 0.066
G N1 APARTMENT 1.71 2.50 268.97 0.353 0.057 0.000 0.065
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.057 0.000 0.065
G S1 APARTMENT 1.71 2.50 268.97 0.353 0.057 0.000 0.067
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.057 0.000 0.067
M SW APARTMENT 1.71 2.50 268.97 0.354 0.135 0.000 0.078
M NW APARTMENT 1.71 2.50 268.97 0.354 0.135 0.000 0.078
M SE APARTMENT 1.71 2.50 268.97 0.354 0.135 0.000 0.078
M NE APARTMENT 1.71 2.50 268.97 0.354 0.135 0.000 0.078
M N1 APARTMENT 1.71 2.50 268.97 0.354 0.082 0.000 0.078
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.082 0.000 0.078
M S1 APARTMENT 1.71 2.50 268.97 0.354 0.082 0.000 0.078
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.082 0.000 0.078
T SW APARTMENT 1.71 2.50 268.97 0.354 0.179 0.000 0.088
T NW APARTMENT 1.71 2.50 268.97 0.353 0.179 0.000 0.088
T SE APARTMENT 1.71 2.50 268.97 0.354 0.179 0.000 0.088
T NE APARTMENT 1.71 2.50 268.97 0.353 0.179 0.000 0.088
T N1 APARTMENT 1.71 2.50 268.97 0.353 0.108 0.000 0.088
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.108 0.000 0.088
T S1 APARTMENT 1.71 2.50 268.97 0.354 0.108 0.000 0.088
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.108 0.000 0.088
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.355 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.503 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.369 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.368 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.370 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.370 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 405.21 0.00 01-JAN-00:15 32493.08 05-FEB-07:45
WaterSystems:Electricity 405.21 0.00 01-JAN-00:15 32493.08 05-FEB-07:45
Water Heater:WaterSystems:Electricity 405.21 0.00 01-JAN-00:15 32493.08 05-FEB-07:45
Fans:Electricity 211.94 6720.50 05-JAN-17:15 6720.50 03-JAN-17:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
ElectricityPurchased:Plant 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
Cogeneration:ElectricityPurchased 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
ElectricityNet:Plant 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
Cogeneration:ElectricityNet 1399.68 20090.79 01-JAN-03:15 83445.56 10-AUG-17:30
ExteriorLights:Electricity 39.36 0.00 01-JAN-08:15 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.36 0.00 01-JAN-08:15 2508.33 01-JAN-00:15
Electricity:HVAC 278.68 6720.50 05-JAN-17:15 25901.44 29-AUG-15:15
General:Fans:Electricity 211.94 6720.50 05-JAN-17:15 6720.50 03-JAN-17:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 66.74 0.00 01-JAN-00:15 19180.94 29-AUG-15:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 146.96 0.00 11-JAN-17:30 52217.55 19-FEB-06:00
Gas:HVAC 146.96 0.00 11-JAN-17:30 52217.55 19-FEB-06:00
Heating:Gas 146.96 0.00 11-JAN-17:30 52217.55 19-FEB-06:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:30


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 785.16 2282.32 08-MAR-18:00 133672.02 10-AUG-15:15
EnergyTransfer:Building 398.98 1987.70 08-MAR-18:00 58857.19 10-AUG-16:15
EnergyTransfer:Zone:G SW APARTMENT 8.23 0.01 07-DEC-19:45 2003.01 10-AUG-16:15
Heating:EnergyTransfer 46.38 0.00 01-FEB-13:15 21795.59 19-FEB-04:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.79 0.00 02-JAN-19:30 780.94 19-FEB-04:00
Cooling:EnergyTransfer 352.59 75.70 28-JAN-03:45 58857.19 10-AUG-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 6.44 0.00 01-JAN-00:15 2003.01 10-AUG-16:15
EnergyTransfer:Zone:G NW APARTMENT 7.11 0.05 08-OCT-12:45 1669.94 10-AUG-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.61 0.00 02-JAN-19:30 876.90 19-FEB-08:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.49 0.00 01-JAN-00:15 1669.94 10-AUG-17:30
EnergyTransfer:Zone:OFFICE 17.99 0.03 28-APR-02:00 3339.07 29-AUG-12:30
Heating:EnergyTransfer:Zone:OFFICE 0.15 0.00 01-JAN-00:15 1702.22 16-JAN-07:15
Cooling:EnergyTransfer:Zone:OFFICE 17.84 0.00 02-JAN-07:30 3339.07 29-AUG-12:30
EnergyTransfer:Zone:G NE APARTMENT 7.33 0.01 30-MAR-09:00 1144.95 24-JUL-18:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 2.60 0.00 02-JAN-19:30 834.28 19-FEB-04:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.73 0.00 01-JAN-00:15 1144.95 24-JUL-18:00
EnergyTransfer:Zone:G N1 APARTMENT 6.00 0.02 08-NOV-01:45 921.46 24-JUL-18:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.78 0.00 01-JAN-16:15 464.37 19-FEB-08:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 5.23 0.00 01-JAN-00:15 921.46 24-JUL-18:15
EnergyTransfer:Zone:G N2 APARTMENT 6.01 0.05 31-MAY-13:00 915.00 24-JUL-18:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.78 0.00 01-JAN-16:15 460.76 19-FEB-08:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 5.23 0.00 01-JAN-00:15 915.00 24-JUL-18:15
EnergyTransfer:Zone:G S1 APARTMENT 7.46 0.03 13-MAY-15:15 1289.98 29-AUG-12:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.40 0.00 01-JAN-10:30 394.22 19-FEB-04:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 7.06 0.00 01-JAN-00:15 1289.98 29-AUG-12:30
EnergyTransfer:Zone:G S2 APARTMENT 7.37 0.02 25-JAN-11:00 1283.58 29-AUG-12:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.48 0.00 01-JAN-17:15 466.65 19-FEB-04:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 6.88 0.00 01-JAN-00:15 1283.58 29-AUG-12:30
EnergyTransfer:Zone:M SW APARTMENT 31.48 0.43 02-DEC-05:30 5476.70 10-AUG-17:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.85 0.00 01-JAN-10:15 1207.33 19-FEB-07:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 30.62 0.00 01-JAN-00:15 5476.70 10-AUG-17:15
EnergyTransfer:Zone:M NW APARTMENT 23.31 0.11 20-DEC-22:00 4522.47 10-AUG-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 1.77 0.00 01-JAN-10:30 1412.14 19-FEB-06:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 21.53 0.00 01-JAN-00:15 4522.47 10-AUG-17:30
EnergyTransfer:Zone:M SE APARTMENT 31.39 0.07 01-OCT-09:45 4635.54 10-AUG-12:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.87 0.00 01-JAN-10:15 1202.90 19-FEB-07:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 30.52 0.00 01-JAN-00:15 4635.54 10-AUG-12:30
EnergyTransfer:Zone:M NE APARTMENT 23.66 0.00 15-FEB-13:15 3453.66 24-JUL-18:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 1.80 0.00 01-JAN-10:15 1403.20 19-FEB-07:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 21.86 0.00 01-JAN-00:15 3453.66 24-JUL-18:00
EnergyTransfer:Zone:M N1 APARTMENT 24.51 0.68 18-MAR-14:45 2766.95 24-JUL-18:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.08 0.00 01-JAN-02:45 718.34 19-FEB-24:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 24.42 0.00 01-JAN-00:15 2766.95 24-JUL-18:30
EnergyTransfer:Zone:M N2 APARTMENT 24.46 0.16 18-MAR-15:45 2756.37 24-JUL-18:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.08 0.00 01-JAN-02:45 722.20 08-JAN-03:15
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 24.38 0.00 01-JAN-00:15 2756.37 24-JUL-18:30
EnergyTransfer:Zone:M S1 APARTMENT 33.88 1.02 14-JAN-04:15 3827.34 23-SEP-13:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.01 0.00 01-JAN-00:45 476.27 16-FEB-04:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 33.87 0.00 01-JAN-00:15 3827.34 23-SEP-13:30
EnergyTransfer:Zone:M S2 APARTMENT 33.85 1.12 14-JAN-04:15 3833.45 23-SEP-13:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.01 0.00 01-JAN-00:45 473.62 16-FEB-04:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 33.84 0.00 01-JAN-00:15 3833.45 23-SEP-13:30
EnergyTransfer:Zone:T SW APARTMENT 15.51 0.01 14-APR-22:45 3567.86 10-AUG-16:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 4.66 0.00 05-JAN-13:15 1686.36 19-FEB-07:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 10.85 0.00 01-JAN-00:15 3567.86 10-AUG-16:15
EnergyTransfer:Zone:T NW APARTMENT 13.59 0.06 03-NOV-22:00 2993.33 10-AUG-17:15
Heating:EnergyTransfer:Zone:T NW APARTMENT 6.11 0.00 11-JAN-17:00 1739.55 19-FEB-07:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 7.48 0.00 01-JAN-00:15 2993.33 10-AUG-17:15
EnergyTransfer:Zone:T SE APARTMENT 15.35 0.01 18-SEP-03:15 3103.67 10-AUG-14:15
Heating:EnergyTransfer:Zone:T SE APARTMENT 4.62 0.00 03-JAN-10:45 1688.53 19-FEB-07:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 10.73 0.00 01-JAN-00:15 3103.67 10-AUG-14:15
EnergyTransfer:Zone:T NE APARTMENT 13.75 0.00 21-NOV-19:15 2215.54 24-JUL-16:15
Heating:EnergyTransfer:Zone:T NE APARTMENT 6.11 0.00 11-JAN-15:45 1742.80 19-FEB-07:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 7.65 0.00 01-JAN-00:15 2215.54 24-JUL-16:15
EnergyTransfer:Zone:T N1 APARTMENT 10.51 0.05 03-MAR-07:45 1877.75 20-JUL-17:30
Heating:EnergyTransfer:Zone:T N1 APARTMENT 2.97 0.00 02-JAN-18:15 1142.99 19-FEB-06:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 7.54 0.00 01-JAN-00:15 1877.75 20-JUL-17:30
EnergyTransfer:Zone:T N2 APARTMENT 10.49 0.03 27-FEB-14:15 1857.70 20-JUL-17:30
Heating:EnergyTransfer:Zone:T N2 APARTMENT 2.97 0.00 02-JAN-18:15 1142.54 19-FEB-06:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 7.52 0.00 01-JAN-00:15 1857.70 20-JUL-17:30
EnergyTransfer:Zone:T S1 APARTMENT 12.88 0.04 09-NOV-01:15 2699.38 10-AUG-14:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 1.93 0.00 01-JAN-18:15 1081.81 19-FEB-06:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 10.95 0.00 01-JAN-00:15 2699.38 10-AUG-14:15
EnergyTransfer:Zone:T S2 APARTMENT 12.88 0.00 23-FEB-23:45 2704.52 10-AUG-14:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 1.93 0.00 01-JAN-18:15 1081.57 19-FEB-06:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 10.94 0.00 01-JAN-00:15 2704.52 10-AUG-14:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 386.18 0.00 11-JAN-17:30 75568.38 29-AUG-15:15
HeatingCoils:EnergyTransfer 117.57 0.00 11-JAN-17:30 41774.04 19-FEB-06:00
CoolingCoils:EnergyTransfer 268.61 0.00 01-JAN-00:15 75568.38 29-AUG-15:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.794 -6.436 0.000 0.000 3.857 2.413 12.213 11.050 0.000 0.022 0.000 0.000 -6.808 0.000 -4.031 -14.074
G NW APARTMENT 2.614 -4.493 0.000 0.000 3.888 2.413 12.213 5.517 0.000 0.022 0.000 0.000 -6.842 0.000 -3.929 -11.405
OFFICE 0.152 -17.837 0.000 0.000 0.522 21.914 7.534 10.745 0.000 0.017 0.000 0.000 -6.666 0.000 -3.014 -13.367
G NE APARTMENT 2.601 -4.726 0.000 0.000 3.903 2.413 12.213 5.204 0.000 0.022 0.000 0.000 -6.707 0.000 -3.908 -11.015
G N1 APARTMENT 0.779 -5.225 0.000 0.000 3.897 2.413 12.213 1.896 0.000 0.018 0.000 0.000 -4.197 0.000 -2.705 -9.088
G N2 APARTMENT 0.780 -5.226 0.000 0.000 3.898 2.413 12.213 1.896 0.000 0.018 0.000 0.000 -4.196 0.000 -2.704 -9.091
G S1 APARTMENT 0.401 -7.059 0.000 0.000 3.850 2.413 12.213 7.472 0.000 0.017 0.000 0.000 -4.167 0.000 -2.826 -12.314
G S2 APARTMENT 0.481 -6.884 0.000 0.000 3.850 2.413 12.213 7.473 0.000 0.017 0.000 0.000 -4.162 0.000 -2.827 -12.573
M SW APARTMENT 0.854 -30.622 0.000 0.000 3.695 2.413 12.213 10.583 0.000 0.030 14.300 0.000 -7.635 0.000 -5.831 -0.000
M NW APARTMENT 1.775 -21.533 0.000 0.000 3.749 2.413 12.213 5.123 0.000 0.030 9.526 0.000 -7.575 0.000 -5.721 -0.000
M SE APARTMENT 0.871 -30.521 0.000 0.000 3.700 2.413 12.213 10.279 0.000 0.030 14.356 0.000 -7.516 0.000 -5.825 -0.000
M NE APARTMENT 1.799 -21.863 0.000 0.000 3.764 2.413 12.213 4.805 0.000 0.030 9.944 0.000 -7.410 0.000 -5.695 -0.001
M N1 APARTMENT 0.082 -24.425 0.000 0.000 3.727 2.413 12.213 1.651 0.000 0.022 13.002 0.000 -4.737 0.000 -3.949 -0.000
M N2 APARTMENT 0.080 -24.382 0.000 0.000 3.729 2.413 12.213 1.651 0.000 0.022 12.955 0.000 -4.734 0.000 -3.947 -0.000
M S1 APARTMENT 0.012 -33.868 0.000 0.000 3.652 2.413 12.213 7.172 0.000 0.023 17.157 0.000 -4.733 0.000 -4.039 -0.000
M S2 APARTMENT 0.011 -33.836 0.000 0.000 3.652 2.413 12.213 7.172 0.000 0.023 17.123 0.000 -4.732 0.000 -4.039 -0.000
T SW APARTMENT 4.660 -10.849 0.000 0.000 3.795 2.413 12.213 10.562 0.000 0.040 0.000 0.000 -7.089 0.000 -7.219 -8.526
T NW APARTMENT 6.111 -7.480 0.000 0.000 3.838 2.413 12.213 5.135 0.000 0.040 0.000 0.000 -7.056 0.000 -7.093 -8.122
T SE APARTMENT 4.623 -10.730 0.000 0.000 3.801 2.413 12.213 10.279 0.000 0.040 0.000 0.000 -6.990 0.000 -7.214 -8.436
T NE APARTMENT 6.107 -7.645 0.000 0.000 3.856 2.413 12.213 4.845 0.000 0.040 0.000 0.000 -6.916 0.000 -7.063 -7.849
T N1 APARTMENT 2.967 -7.540 0.000 0.000 3.835 2.413 12.213 1.693 0.000 0.030 0.000 0.000 -4.351 0.000 -4.782 -6.476
T N2 APARTMENT 2.971 -7.519 0.000 0.000 3.836 2.413 12.213 1.692 0.000 0.030 0.000 0.000 -4.348 0.000 -4.782 -6.506
T S1 APARTMENT 1.929 -10.949 0.000 0.000 3.770 2.413 12.213 7.177 0.000 0.030 0.000 0.000 -4.383 0.000 -4.906 -7.295
T S2 APARTMENT 1.933 -10.942 0.000 0.000 3.771 2.413 12.213 7.176 0.000 0.030 0.000 0.000 -4.382 0.000 -4.906 -7.305
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.043 0.000 0.001 0.000 0.000 -0.894 0.000 -1.115 -15.105
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.183 0.000 0.047 0.000 0.000 -2.327 0.000 -19.582 -1.656
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.042 0.000 0.001 0.000 0.000 -0.998 0.000 -0.932 -15.183
Total Facility 46.384 -352.591 0.000 0.000 87.835 128.627 294.692 148.516 0.000 0.692 108.364 0.000 -142.551 0.000 -134.585 -185.384


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 10-AUG-16:15 0.00 -2004.13 0.00 0.00 84.76 144.04 588.62 2286.28 0.00 25.39 0.00 0.00 0.00 0.00 0.00 -1124.95
G NW APARTMENT 10-AUG-17:23 0.00 -1670.05 0.00 0.00 141.80 194.45 588.62 1853.40 0.00 36.65 0.00 0.00 0.00 0.00 0.00 -1144.87
OFFICE 29-AUG-12:30 0.00 -3339.16 0.00 0.00 67.31 1622.34 544.92 2449.85 0.00 30.74 0.00 0.00 0.00 0.00 0.00 -1376.00
G NE APARTMENT 24-JUL-18:00 0.00 -1144.95 0.00 0.00 141.81 194.45 588.62 574.12 0.00 43.14 0.00 0.00 0.00 0.00 0.00 -397.19
G N1 APARTMENT 24-JUL-18:15 0.00 -921.45 0.00 0.00 141.81 230.46 547.42 389.23 0.00 23.79 0.00 0.00 0.00 0.00 0.00 -411.26
G N2 APARTMENT 24-JUL-18:15 0.00 -914.99 0.00 0.00 141.81 230.46 547.42 389.34 0.00 23.79 0.00 0.00 0.00 0.00 0.00 -417.83
G S1 APARTMENT 29-AUG-12:30 0.00 -1289.90 0.00 0.00 40.75 28.81 388.49 2201.19 0.00 16.59 0.00 0.00 0.00 0.00 0.00 -1385.93
G S2 APARTMENT 29-AUG-12:30 0.00 -1283.50 0.00 0.00 40.75 28.81 388.49 2201.30 0.00 16.59 0.00 0.00 0.00 0.00 0.00 -1392.44
M SW APARTMENT 10-AUG-17:10 0.00 -5477.67 0.00 0.00 141.80 194.45 588.62 1894.05 0.00 54.57 2604.16 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 10-AUG-17:30 0.00 -4522.73 0.00 0.00 141.80 194.45 588.62 1839.75 0.00 52.51 1705.59 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 10-AUG-12:30 0.00 -4635.73 0.00 0.00 40.75 28.81 388.49 2105.72 0.00 75.21 1996.75 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 24-JUL-18:00 0.00 -3453.65 0.00 0.00 141.81 194.45 588.62 560.01 0.00 61.72 1907.04 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 24-JUL-18:30 0.00 -2766.88 0.00 0.00 141.81 230.46 547.42 388.06 0.00 30.94 1428.20 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 24-JUL-18:30 0.00 -2756.30 0.00 0.00 141.81 230.46 547.42 388.13 0.00 30.94 1417.55 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 23-SEP-13:30 0.00 -3827.27 0.00 0.00 40.75 28.81 382.60 2093.64 0.00 0.00 1318.07 0.00 0.00 0.00 -36.60 0.00
M S2 APARTMENT 23-SEP-13:30 0.00 -3833.38 0.00 0.00 40.75 28.81 382.60 2093.60 0.00 0.00 1324.22 0.00 0.00 0.00 -36.60 0.00
T SW APARTMENT 10-AUG-16:08 0.00 -3568.48 0.00 0.00 84.76 144.04 588.62 2235.41 0.00 47.85 467.80 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 10-AUG-17:15 0.00 -2994.17 0.00 0.00 141.81 194.45 588.62 1868.47 0.00 71.78 129.04 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 10-AUG-14:15 0.00 -3103.57 0.00 0.00 40.75 50.41 400.26 1745.25 0.00 38.48 828.41 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 24-JUL-16:08 0.00 -2215.68 0.00 0.00 84.76 144.04 588.62 621.80 0.00 76.10 700.37 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 20-JUL-17:30 0.00 -1878.03 0.00 0.00 141.80 194.45 588.62 342.03 0.00 149.72 461.40 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 20-JUL-17:30 0.00 -1857.97 0.00 0.00 141.80 194.45 588.62 342.34 0.00 149.72 441.04 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 10-AUG-14:15 0.00 -2699.28 0.00 0.00 40.75 50.41 400.26 1532.71 0.00 23.21 651.93 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 10-AUG-14:15 0.00 -2704.42 0.00 0.00 40.75 50.41 400.26 1532.62 0.00 23.21 657.16 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 10-AUG-16:15 0.00 -58868.92 0.00 0.00 1949.41 5316.35 14137.32 21833.25 0.00 1725.15 13907.44 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 19-FEB-04:00 780.92 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -709.22 0.00 -255.04 -244.42
G NW APARTMENT 29-OCT-06:01 1594.29 0.00 0.00 0.00 163.28 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -389.92 0.00 -83.77 -1760.11
OFFICE 17-DEC-07:01 3456.59 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -341.36 0.00 -191.99 -3497.82
G NE APARTMENT 31-OCT-16:01 1620.19 0.00 0.00 0.00 99.85 144.04 588.62 0.00 0.00 0.00 0.00 0.00 -283.53 0.00 -259.29 -1909.88
G N1 APARTMENT 29-MAR-06:01 1222.72 0.00 0.00 0.00 161.33 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -226.93 0.00 -121.29 -1512.07
G N2 APARTMENT 29-MAR-06:01 1221.68 0.00 0.00 0.00 161.33 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -226.93 0.00 -121.28 -1511.03
G S1 APARTMENT 16-DEC-17:01 1350.88 0.00 0.00 0.00 99.83 144.04 588.62 0.00 0.00 0.00 0.00 0.00 -306.92 0.00 -100.99 -1775.47
G S2 APARTMENT 29-NOV-07:01 1363.14 0.00 0.00 0.00 163.18 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -236.04 0.00 -171.92 -1594.59
M SW APARTMENT 19-DEC-07:01 3113.35 0.00 0.00 0.00 163.04 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -481.44 0.00 -115.20 -3155.99
M NW APARTMENT 19-FEB-06:00 1412.07 0.00 0.00 0.00 189.67 93.63 253.11 0.00 0.00 0.00 0.00 0.00 -754.02 0.00 -422.09 -772.36
M SE APARTMENT 21-FEB-07:01 1245.08 0.00 0.00 0.00 161.66 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -380.52 0.00 -173.51 -1328.94
M NE APARTMENT 06-MAR-07:01 3168.36 0.00 0.00 0.00 163.12 93.63 382.60 41.82 0.00 0.00 0.00 0.00 0.00 0.00 -290.22 -3559.32
M N1 APARTMENT 07-JAN-08:28 1977.27 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -382.37 0.00 -121.70 -1978.87
M N2 APARTMENT 07-JAN-08:26 1980.72 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -382.35 0.00 -121.71 -1982.34
M S1 APARTMENT 16-FEB-04:00 476.20 0.00 0.00 0.00 191.99 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -306.30 0.00 -317.42 -282.56
M S2 APARTMENT 16-FEB-04:00 473.55 0.00 0.00 0.00 191.98 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -306.31 0.00 -317.42 -279.88
T SW APARTMENT 19-FEB-07:00 1686.31 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -689.51 0.00 -616.81 -988.34
T NW APARTMENT 19-FEB-07:00 1739.50 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -701.27 0.00 -616.81 -1029.77
T SE APARTMENT 19-FEB-07:00 1688.48 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -699.50 0.00 -616.81 -980.52
T NE APARTMENT 19-FEB-07:00 1742.76 0.00 0.00 0.00 189.67 100.83 317.86 0.00 0.00 0.00 0.00 0.00 -711.21 0.00 -616.81 -1023.09
T N1 APARTMENT 17-APR-06:01 1966.66 0.00 0.00 0.00 163.42 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -216.10 0.00 -108.27 -2281.93
T N2 APARTMENT 03-MAR-07:01 1963.35 0.00 0.00 0.00 163.36 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -214.75 0.00 -115.02 -2273.17
T S1 APARTMENT 05-MAR-17:01 1250.28 0.00 0.00 0.00 99.38 144.04 588.62 0.00 0.00 0.00 0.00 0.00 -222.94 0.00 -129.70 -1729.68
T S2 APARTMENT 18-MAR-06:01 1790.31 0.00 0.00 0.00 162.72 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -302.52 0.00 -145.34 -1981.40
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 19-FEB-04:00 21284.44 0.00 0.00 0.00 4362.43 2334.74 5313.65 0.00 0.00 0.00 0.00 0.00 -14111.25 0.00 -7258.44 -11925.58



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sec1.1A-General Information

Data
Weather File Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 86.25
Number of hours cooling loads not met 0.00
Number of hours not met 86.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 8572.78 0.00 0.00 0.00 0.00
Exterior Lighting 39.36 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 146.96 52217.55 0.00 0.00
Space Cooling 66.74 18773.17 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 211.94 6720.50 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 405.21 22922.71 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 26456.41 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1399.68   146.96   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1399.68
Natural Gas 0.00 146.96
Additional 0.00 0.00
Total 511.42 1546.64


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 21.29
Fans-Interior 67.61
Service Water Heating 129.27
Receptacle Equipment 163.15
Miscellaneous 12.56
Subtotal 446.52


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 46.88
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 46.88


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 10.67
Space Heating 9.50
Space Cooling 4.32
Fans-Interior 13.70
Service Water Heating 26.20
Receptacle Equipment 33.07
Miscellaneous 2.55



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.177225
G NW APARTMENT DIRECT AIR 0.141589
OFFICE DIRECT AIR 0.447039
G NE APARTMENT DIRECT AIR 0.096121
G N1 APARTMENT DIRECT AIR 0.079148
G N2 APARTMENT DIRECT AIR 0.078044
G S1 APARTMENT DIRECT AIR 0.130406
G S2 APARTMENT DIRECT AIR 0.133562
M SW APARTMENT DIRECT AIR 0.491446
M NW APARTMENT DIRECT AIR 0.391131
M SE APARTMENT DIRECT AIR 0.456376
M NE APARTMENT DIRECT AIR 0.291734
M N1 APARTMENT DIRECT AIR 0.231755
M N2 APARTMENT DIRECT AIR 0.229776
M S1 APARTMENT DIRECT AIR 0.370574
M S2 APARTMENT DIRECT AIR 0.371832
T SW APARTMENT DIRECT AIR 0.322556
T NW APARTMENT DIRECT AIR 0.250659
T SE APARTMENT DIRECT AIR 0.302387
T NE APARTMENT DIRECT AIR 0.187338
T N1 APARTMENT DIRECT AIR 0.148877
T N2 APARTMENT DIRECT AIR 0.148548
T S1 APARTMENT DIRECT AIR 0.260458
T S2 APARTMENT DIRECT AIR 0.261282


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.177225
SPLIT GNW MAIN BRANCH 0.141589
SPLIT OFFICE MAIN BRANCH 0.447039
SPLIT GNE MAIN BRANCH 0.096121
SPLIT GN1 MAIN BRANCH 0.079148
SPLIT GN2 MAIN BRANCH 0.078044
SPLIT GS1 MAIN BRANCH 0.130406
SPLIT GS2 MAIN BRANCH 0.133562
SPLIT MSW MAIN BRANCH 0.491446
SPLIT MNW MAIN BRANCH 0.391131
SPLIT MSE MAIN BRANCH 0.456376
SPLIT MNE MAIN BRANCH 0.291734
SPLIT MN1 MAIN BRANCH 0.231755
SPLIT MN2 MAIN BRANCH 0.229776
SPLIT MS1 MAIN BRANCH 0.370574
SPLIT MS2 MAIN BRANCH 0.371832
SPLIT TSW MAIN BRANCH 0.322556
SPLIT TNW MAIN BRANCH 0.250659
SPLIT TSE MAIN BRANCH 0.302387
SPLIT TNE MAIN BRANCH 0.187338
SPLIT TN1 MAIN BRANCH 0.148877
SPLIT TN2 MAIN BRANCH 0.148548
SPLIT TS1 MAIN BRANCH 0.260458
SPLIT TS2 MAIN BRANCH 0.261282


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.177225
SPLIT GNW 0.141589
SPLIT OFFICE 0.447039
SPLIT GNE 0.096121
SPLIT GN1 0.079148
SPLIT GN2 0.078044
SPLIT GS1 0.130406
SPLIT GS2 0.133562
SPLIT MSW 0.491446
SPLIT MNW 0.391131
SPLIT MSE 0.456376
SPLIT MNE 0.291734
SPLIT MN1 0.231755
SPLIT MN2 0.229776
SPLIT MS1 0.370574
SPLIT MS2 0.371832
SPLIT TSW 0.322556
SPLIT TNW 0.250659
SPLIT TSE 0.302387
SPLIT TNE 0.187338
SPLIT TN1 0.148877
SPLIT TN2 0.148548
SPLIT TS1 0.260458
SPLIT TS2 0.261282


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.177225 0.026898
SPLIT GNW OA CONTROLLER 0.141589 0.025953
SPLIT OFFICE OA CONTROLLER 0.447039 0.038104
SPLIT GNE OA CONTROLLER 0.096121 0.025953
SPLIT GN1 OA CONTROLLER 0.079148 0.025953
SPLIT GN2 OA CONTROLLER 0.078044 0.025953
SPLIT GS1 OA CONTROLLER 0.130406 0.025953
SPLIT GS2 OA CONTROLLER 0.133562 0.025953
SPLIT MSW OA CONTROLLER 0.491446 0.051906
SPLIT MNW OA CONTROLLER 0.391131 0.051906
SPLIT MSE OA CONTROLLER 0.456376 0.051906
SPLIT MNE OA CONTROLLER 0.291734 0.051906
SPLIT MN1 OA CONTROLLER 0.231755 0.051906
SPLIT MN2 OA CONTROLLER 0.229776 0.051906
SPLIT MS1 OA CONTROLLER 0.370574 0.051906
SPLIT MS2 OA CONTROLLER 0.371832 0.051906
SPLIT TSW OA CONTROLLER 0.322556 0.025953
SPLIT TNW OA CONTROLLER 0.250659 0.025953
SPLIT TSE OA CONTROLLER 0.302387 0.025953
SPLIT TNE OA CONTROLLER 0.187338 0.025953
SPLIT TN1 OA CONTROLLER 0.148877 0.025953
SPLIT TN2 OA CONTROLLER 0.148548 0.025953
SPLIT TS1 OA CONTROLLER 0.260458 0.025953
SPLIT TS2 OA CONTROLLER 0.261282 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.177225 2933.70 0.798655
SPLIT GNW COOLING COIL 0.141589 2343.80 0.798655
SPLIT OFFICE COOLING COIL 0.447039 7400.08 0.798655
SPLIT GNE COOLING COIL 0.096121 1591.15 0.798655
SPLIT GN1 COOLING COIL 0.079148 1310.18 0.798655
SPLIT GN2 COOLING COIL 0.078044 1291.91 0.798655
SPLIT GS1 COOLING COIL 0.130406 2199.69 0.791802
SPLIT GS2 COOLING COIL 0.133562 2242.82 0.793427
SPLIT MSW COOLING COIL 0.491446 8135.17 0.798655
SPLIT MNW COOLING COIL 0.391131 6474.61 0.798655
SPLIT MSE COOLING COIL 0.456376 7554.64 0.798655
SPLIT MNE COOLING COIL 0.291734 4829.24 0.798655
SPLIT MN1 COOLING COIL 0.231755 3836.37 0.798655
SPLIT MN2 COOLING COIL 0.229776 3803.61 0.798655
SPLIT MS1 COOLING COIL 0.370574 6134.31 0.798655
SPLIT MS2 COOLING COIL 0.371832 6155.14 0.798655
SPLIT TSW COOLING COIL 0.322556 5339.45 0.798655
SPLIT TNW COOLING COIL 0.250659 4149.30 0.798655
SPLIT TSE COOLING COIL 0.302387 5005.58 0.798655
SPLIT TNE COOLING COIL 0.187338 3101.11 0.798655
SPLIT TN1 COOLING COIL 0.148877 2480.99 0.796204
SPLIT TN2 COOLING COIL 0.148548 2482.64 0.795156
SPLIT TS1 COOLING COIL 0.260458 4311.50 0.798655
SPLIT TS2 COOLING COIL 0.261282 4325.15 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.177225 0.177225 0.177225 0.177225 1948.11 2933.70 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.141589 0.141589 0.141589 0.141589 1926.74 2343.80 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.447039 0.447039 0.447039 0.447039 3758.68 7400.08 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.096121 0.096121 0.096121 0.096121 1931.71 1591.15 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.079148 0.079148 0.079148 0.079148 1677.79 1310.18 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.078044 0.078044 0.078044 0.078044 1677.79 1291.91 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.130406 0.130406 0.130406 0.130406 1677.79 2199.69 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.133562 0.133562 0.133562 0.133562 1677.79 2242.82 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.491446 0.491446 0.491446 0.491446 3796.14 8135.17 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.391131 0.391131 0.391131 0.391131 3819.21 6474.61 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.456376 0.456376 0.456376 0.456376 3809.50 7554.64 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.291734 0.291734 0.291734 0.291734 3832.56 4829.24 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.231755 0.231755 0.231755 0.231755 3355.59 3836.37 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.229776 0.229776 0.229776 0.229776 3355.59 3803.61 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.370574 0.370574 0.370574 0.370574 3355.59 6134.31 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.371832 0.371832 0.371832 0.371832 3355.59 6155.14 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.322556 0.322556 0.322556 0.322556 2977.80 5339.45 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.250659 0.250659 0.250659 0.250659 2991.27 4149.30 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.302387 0.302387 0.302387 0.302387 2984.71 5005.58 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.187338 0.187338 0.187338 0.187338 2998.18 3101.11 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.148877 0.148877 0.148877 0.148877 2317.43 2480.99 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.148548 0.148548 0.148548 0.148548 2317.63 2482.64 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.260458 0.260458 0.260458 0.260458 2301.88 4311.50 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.261282 0.261282 0.261282 0.261282 2302.08 4325.15 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.177225
SPLIT GNW SUPPLY FAN 0.141589
SPLIT OFFICE SUPPLY FAN 0.447039
SPLIT GNE SUPPLY FAN 0.096121
SPLIT GN1 SUPPLY FAN 0.079148
SPLIT GN2 SUPPLY FAN 0.078044
SPLIT GS1 SUPPLY FAN 0.130406
SPLIT GS2 SUPPLY FAN 0.133562
SPLIT MSW SUPPLY FAN 0.491446
SPLIT MNW SUPPLY FAN 0.391131
SPLIT MSE SUPPLY FAN 0.456376
SPLIT MNE SUPPLY FAN 0.291734
SPLIT MN1 SUPPLY FAN 0.231755
SPLIT MN2 SUPPLY FAN 0.229776
SPLIT MS1 SUPPLY FAN 0.370574
SPLIT MS2 SUPPLY FAN 0.371832
SPLIT TSW SUPPLY FAN 0.322556
SPLIT TNW SUPPLY FAN 0.250659
SPLIT TSE SUPPLY FAN 0.302387
SPLIT TNE SUPPLY FAN 0.187338
SPLIT TN1 SUPPLY FAN 0.148877
SPLIT TN2 SUPPLY FAN 0.148548
SPLIT TS1 SUPPLY FAN 0.260458
SPLIT TS2 SUPPLY FAN 0.261282


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 1948.11
SPLIT GNW HEATING COIL 1926.74
SPLIT OFFICE HEATING COIL 3758.68
SPLIT GNE HEATING COIL 1931.71
SPLIT GN1 HEATING COIL 1677.79
SPLIT GN2 HEATING COIL 1677.79
SPLIT GS1 HEATING COIL 1677.79
SPLIT GS2 HEATING COIL 1677.79
SPLIT MSW HEATING COIL 3796.14
SPLIT MNW HEATING COIL 3819.21
SPLIT MSE HEATING COIL 3809.50
SPLIT MNE HEATING COIL 3832.56
SPLIT MN1 HEATING COIL 3355.59
SPLIT MN2 HEATING COIL 3355.59
SPLIT MS1 HEATING COIL 3355.59
SPLIT MS2 HEATING COIL 3355.59
SPLIT TSW HEATING COIL 2977.80
SPLIT TNW HEATING COIL 2991.27
SPLIT TSE HEATING COIL 2984.71
SPLIT TNE HEATING COIL 2998.18
SPLIT TN1 HEATING COIL 2317.43
SPLIT TN2 HEATING COIL 2317.63
SPLIT TS1 HEATING COIL 2301.88
SPLIT TS2 HEATING COIL 2302.08



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.50
February 21.88 5.82
March 22.09 8.33
April 22.52 10.85
May 22.93 12.97
June 24.06 15.59
July 24.32 17.66
August 24.33 18.80
September 24.21 15.09
October 22.65 11.43
November 21.89 8.07
December 21.76 5.42
     
Annual Sum or Average 22.87 11.24
Minimum of Months 21.72 4.50
Maximum of Months 24.33 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.74 5.82
March 21.81 8.33
April 22.17 10.85
May 22.64 12.97
June 23.93 15.59
July 24.27 17.66
August 24.28 18.80
September 24.04 15.09
October 22.14 11.43
November 21.77 8.07
December 21.70 5.42
     
Annual Sum or Average 22.69 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.28 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.10 4.50
February 21.59 5.82
March 22.39 8.33
April 22.91 10.85
May 23.31 12.97
June 23.87 15.59
July 23.90 17.66
August 23.90 18.80
September 23.89 15.09
October 23.12 11.43
November 22.10 8.07
December 21.34 5.42
     
Annual Sum or Average 22.79 11.24
Minimum of Months 21.10 4.50
Maximum of Months 23.90 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.72 5.82
March 21.75 8.33
April 22.11 10.85
May 22.52 12.97
June 23.89 15.59
July 24.20 17.66
August 24.25 18.80
September 23.93 15.09
October 22.04 11.43
November 21.75 8.07
December 21.70 5.42
     
Annual Sum or Average 22.64 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.25 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.73 5.82
March 21.77 8.33
April 22.05 10.85
May 22.42 12.97
June 23.87 15.59
July 24.23 17.66
August 24.27 18.80
September 24.00 15.09
October 22.09 11.43
November 21.77 8.07
December 21.70 5.42
     
Annual Sum or Average 22.64 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.27 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.73 5.82
March 21.77 8.33
April 22.04 10.85
May 22.41 12.97
June 23.87 15.59
July 24.22 17.66
August 24.26 18.80
September 23.99 15.09
October 22.09 11.43
November 21.77 8.07
December 21.70 5.42
     
Annual Sum or Average 22.63 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.26 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.50
February 21.91 5.82
March 22.12 8.33
April 22.51 10.85
May 22.86 12.97
June 24.10 15.59
July 24.33 17.66
August 24.35 18.80
September 24.26 15.09
October 22.78 11.43
November 21.96 8.07
December 21.79 5.42
     
Annual Sum or Average 22.90 11.24
Minimum of Months 21.73 4.50
Maximum of Months 24.35 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.50
February 21.92 5.82
March 22.13 8.33
April 22.53 10.85
May 22.87 12.97
June 24.10 15.59
July 24.32 17.66
August 24.35 18.80
September 24.25 15.09
October 22.79 11.43
November 21.97 8.07
December 21.79 5.42
     
Annual Sum or Average 22.90 11.24
Minimum of Months 21.73 4.50
Maximum of Months 24.35 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 4.50
February 22.60 5.82
March 23.65 8.33
April 24.11 10.85
May 24.32 12.97
June 24.39 15.59
July 24.40 17.66
August 24.40 18.80
September 24.39 15.09
October 24.17 11.43
November 22.89 8.07
December 22.13 5.42
     
Annual Sum or Average 23.61 11.24
Minimum of Months 21.86 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.50
February 22.01 5.82
March 22.81 8.33
April 23.75 10.85
May 24.26 12.97
June 24.38 15.59
July 24.40 17.66
August 24.40 18.80
September 24.38 15.09
October 23.77 11.43
November 22.34 8.07
December 21.72 5.42
     
Annual Sum or Average 23.33 11.24
Minimum of Months 21.71 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 4.50
February 22.56 5.82
March 23.64 8.33
April 24.11 10.85
May 24.31 12.97
June 24.38 15.59
July 24.40 17.66
August 24.40 18.80
September 24.39 15.09
October 24.14 11.43
November 22.83 8.07
December 22.10 5.42
     
Annual Sum or Average 23.60 11.24
Minimum of Months 21.84 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.50
February 21.94 5.82
March 22.59 8.33
April 23.69 10.85
May 24.21 12.97
June 24.37 15.59
July 24.40 17.66
August 24.40 18.80
September 24.36 15.09
October 23.62 11.43
November 22.23 8.07
December 21.71 5.42
     
Annual Sum or Average 23.28 11.24
Minimum of Months 21.71 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 4.50
February 22.09 5.82
March 23.08 8.33
April 23.93 10.85
May 24.32 12.97
June 24.39 15.59
July 24.40 17.66
August 24.40 18.80
September 24.39 15.09
October 24.02 11.43
November 22.57 8.07
December 21.76 5.42
     
Annual Sum or Average 23.43 11.24
Minimum of Months 21.75 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 4.50
February 22.09 5.82
March 23.05 8.33
April 23.93 10.85
May 24.32 12.97
June 24.39 15.59
July 24.40 17.66
August 24.40 18.80
September 24.39 15.09
October 24.01 11.43
November 22.56 8.07
December 21.76 5.42
     
Annual Sum or Average 23.43 11.24
Minimum of Months 21.75 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 4.50
February 23.00 5.82
March 24.03 8.33
April 24.27 10.85
May 24.37 12.97
June 24.40 15.59
July 24.40 17.66
August 24.40 18.80
September 24.40 15.09
October 24.33 11.43
November 23.43 8.07
December 22.50 5.42
     
Annual Sum or Average 23.81 11.24
Minimum of Months 22.10 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 4.50
February 23.00 5.82
March 24.03 8.33
April 24.27 10.85
May 24.37 12.97
June 24.40 15.59
July 24.40 17.66
August 24.40 18.80
September 24.40 15.09
October 24.33 11.43
November 23.42 8.07
December 22.50 5.42
     
Annual Sum or Average 23.80 11.24
Minimum of Months 22.10 4.50
Maximum of Months 24.40 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 4.50
February 22.20 5.82
March 22.67 8.33
April 23.29 10.85
May 23.81 12.97
June 24.21 15.59
July 24.37 17.66
August 24.36 18.80
September 24.21 15.09
October 23.14 11.43
November 22.18 8.07
December 21.89 5.42
     
Annual Sum or Average 23.18 11.24
Minimum of Months 21.77 4.50
Maximum of Months 24.37 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.86 5.82
March 22.19 8.33
April 22.92 10.85
May 23.62 12.97
June 24.12 15.59
July 24.33 17.66
August 24.31 18.80
September 24.01 15.09
October 22.60 11.43
November 21.91 8.07
December 21.70 5.42
     
Annual Sum or Average 22.95 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.33 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 4.50
February 22.18 5.82
March 22.66 8.33
April 23.31 10.85
May 23.79 12.97
June 24.19 15.59
July 24.35 17.66
August 24.35 18.80
September 24.18 15.09
October 23.12 11.43
November 22.16 8.07
December 21.88 5.42
     
Annual Sum or Average 23.17 11.24
Minimum of Months 21.76 4.50
Maximum of Months 24.35 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.82 5.82
March 22.07 8.33
April 22.89 10.85
May 23.53 12.97
June 24.05 15.59
July 24.27 17.66
August 24.27 18.80
September 23.89 15.09
October 22.48 11.43
November 21.87 8.07
December 21.70 5.42
     
Annual Sum or Average 22.88 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.27 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.86 5.82
March 22.14 8.33
April 22.93 10.85
May 23.67 12.97
June 24.15 15.59
July 24.33 17.66
August 24.32 18.80
September 24.01 15.09
October 22.59 11.43
November 21.93 8.07
December 21.70 5.42
     
Annual Sum or Average 22.95 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.33 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.50
February 21.86 5.82
March 22.14 8.33
April 22.93 10.85
May 23.66 12.97
June 24.15 15.59
July 24.33 17.66
August 24.32 18.80
September 24.00 15.09
October 22.59 11.43
November 21.93 8.07
December 21.70 5.42
     
Annual Sum or Average 22.95 11.24
Minimum of Months 21.70 4.50
Maximum of Months 24.33 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 4.50
February 22.33 5.82
March 22.83 8.33
April 23.48 10.85
May 23.96 12.97
June 24.28 15.59
July 24.39 17.66
August 24.38 18.80
September 24.28 15.09
October 23.38 11.43
November 22.32 8.07
December 21.95 5.42
     
Annual Sum or Average 23.29 11.24
Minimum of Months 21.80 4.50
Maximum of Months 24.39 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 4.50
February 22.33 5.82
March 22.83 8.33
April 23.48 10.85
May 23.95 12.97
June 24.28 15.59
July 24.39 17.66
August 24.38 18.80
September 24.28 15.09
October 23.38 11.43
November 22.33 8.07
December 21.95 5.42
     
Annual Sum or Average 23.29 11.24
Minimum of Months 21.80 4.50
Maximum of Months 24.39 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.50
February 22.32 5.82
March 23.19 8.33
April 24.34 10.85
May 25.29 12.97
June 25.99 15.59
July 26.39 17.66
August 26.39 18.80
September 25.67 15.09
October 23.92 11.43
November 22.52 8.07
December 21.87 5.42
     
Annual Sum or Average 24.15 11.24
Minimum of Months 21.73 4.50
Maximum of Months 26.39 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.46 4.50
February 20.86 5.82
March 21.49 8.33
April 22.23 10.85
May 22.88 12.97
June 24.69 15.59
July 25.36 17.66
August 25.57 18.80
September 24.82 15.09
October 22.52 11.43
November 21.30 8.07
December 20.68 5.42
     
Annual Sum or Average 22.75 11.24
Minimum of Months 20.46 4.50
Maximum of Months 25.57 18.80



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.34 4.50
February 24.01 5.82
March 25.23 8.33
April 26.02 10.85
May 26.52 12.97
June 26.72 15.59
July 26.85 17.66
August 26.86 18.80
September 26.65 15.09
October 26.02 11.43
November 24.50 8.07
December 23.55 5.42
     
Annual Sum or Average 25.53 11.24
Minimum of Months 23.34 4.50
Maximum of Months 26.86 18.80



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.116367E+12 76339.207 04-JAN-18:15 8572.775 26456.413 6720.496 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 32081.193 0.000 0.000 0.000
February 0.105279E+12 73698.125 05-FEB-18:30 8572.775 26456.413 6720.496 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 29440.112 0.000 0.000 0.000
March 0.116490E+12 71490.302 02-MAR-18:00 8572.775 26456.413 6720.496 0.000 1923.619 2508.330 0.000 0.000 0.000 0.000 0.000 25308.670 0.000 0.000 0.000
April 0.113880E+12 78677.416 27-APR-17:15 8572.775 26456.413 6720.496 0.000 13210.104 0.000 0.000 0.000 0.000 0.000 0.000 23717.629 0.000 0.000 0.000
May 0.119060E+12 76022.132 05-MAY-17:15 8572.775 26456.413 6720.496 0.000 9895.824 0.000 0.000 0.000 0.000 0.000 0.000 24376.625 0.000 0.000 0.000
June 0.117158E+12 78250.378 20-JUN-17:45 8572.775 26456.413 6720.496 0.000 12967.239 0.000 0.000 0.000 0.000 0.000 0.000 23533.456 0.000 0.000 0.000
July 0.124882E+12 80854.274 31-JUL-17:15 8572.775 26456.413 6720.496 0.000 16764.774 0.000 0.000 0.000 0.000 0.000 0.000 22339.817 0.000 0.000 0.000
August 0.126809E+12 83445.562 10-AUG-17:30 8572.775 26456.413 6720.496 0.000 18773.167 0.000 0.000 0.000 0.000 0.000 0.000 22922.712 0.000 0.000 0.000
September 0.117259E+12 78856.847 11-SEP-17:30 8572.775 26456.413 6720.496 0.000 11650.044 0.000 0.000 0.000 0.000 0.000 0.000 25457.120 0.000 0.000 0.000
October 0.115625E+12 70910.963 04-OCT-17:30 8572.775 26456.413 6720.496 0.000 6880.049 0.000 0.000 0.000 0.000 0.000 0.000 22281.231 0.000 0.000 0.000
November 0.111141E+12 70252.999 04-NOV-17:30 8572.775 26456.413 6720.496 0.000 3917.933 2508.330 0.000 0.000 0.000 0.000 0.000 22077.052 0.000 0.000 0.000
December 0.115728E+12 70606.899 27-DEC-18:15 8572.775 26456.413 6720.496 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 26348.886 0.000 0.000 0.000
                                     
Annual Sum or Average 0.139968E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.105279E+12 70252.999   8572.775 26456.413 6720.496 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 22077.052 0.000 0.000 0.000
Maximum of Months 0.126809E+12 83445.562   8572.775 26456.413 6720.496 0.000 18773.167 2508.330 0.000 0.000 0.000 0.000 0.000 32081.193 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.441000E+11 43434.379 15-JAN-04:00 43434.379 0.000 0.000 0.000 0.000 0.000 43434.379
February 0.283990E+11 52217.547 19-FEB-05:00 52217.547 0.000 0.000 0.000 0.000 0.000 52217.547
March 0.110478E+11 21006.184 05-MAR-03:00 21006.184 0.000 0.000 0.000 0.000 0.000 21006.184
April 0.440410E+10 14727.463 11-APR-03:00 14727.463 0.000 0.000 0.000 0.000 0.000 14727.463
May 0.105648E+10 10220.557 18-MAY-04:00 10220.557 0.000 0.000 0.000 0.000 0.000 10220.557
June 5302928.428 425.969 14-JUN-03:15 425.969 0.000 0.000 0.000 0.000 0.000 425.969
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.144046E+08 888.241 27-SEP-03:00 888.241 0.000 0.000 0.000 0.000 0.000 888.241
October 0.310133E+10 10578.747 28-OCT-03:00 10578.747 0.000 0.000 0.000 0.000 0.000 10578.747
November 0.182453E+11 28575.354 30-NOV-00:00 28575.354 0.000 0.000 0.000 0.000 0.000 28575.354
December 0.365864E+11 39292.522 26-DEC-03:00 39292.522 0.000 0.000 0.000 0.000 0.000 39292.522
                     
Annual Sum or Average 0.146960E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.441000E+11 52217.547   52217.547 0.000 0.000 0.000 0.000 0.000 52217.547