Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695

Simulation Timestamp: 2018-10-19 09:20:29


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1728.52 551.43 612.09
Net Site Energy 1728.52 551.43 612.09
Total Source Energy 5018.22 1600.90 1777.00
Net Source Energy 5018.22 1600.90 1777.00


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 218.92 0.00 0.00 0.00 0.00
Cooling 123.12 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.40 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 255.72 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 414.94 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1509.60 218.92 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 218.92 0.00 0.00 0.00 0.00
Cooling General 123.12 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.40 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 255.72 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 414.94 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.38 0.00 0.00 0.00 0.00 0.00
HVAC 281.09 77.52 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 534.57 77.52 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.21 0.00 0.00 0.00 0.00 0.00
HVAC 253.23 69.84 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 481.59 69.84 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1509.60 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1509.60 100.00
     
Total On-Site and Utility Electric Sources 1509.60 100.00
Total Electricity End Uses 1509.60 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 48.00
Time Setpoint Not Met During Occupied Cooling 2.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 1939.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Weather File Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Latitude [deg] 39.72
Longitude [deg] -104.8
Elevation [m] 1726.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 14-JUN-17:00 22-DEC-03:00 - - - 01-JAN-07:15
Heating 0.00 96671.03 0.00 0.00 0.00 0.00
Cooling 19196.01 0.00 0.00 0.00 0.00 0.00
Interior Lighting 8572.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 8108.93 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 29773.86 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 92107.98 96671.03 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 96671.03 0.00 0.00 0.00 0.00
Cooling General 19196.01 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7168.38 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1404.40 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 8108.93 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 29773.86 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 237.31 0.00 0.00 0.00
Cooling 389.92 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 124.77 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 809.88 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1314.12 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4780.91 237.31 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 84.03 0.00 0.00 0.00
Cooling 138.07 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.18 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 286.79 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 465.34 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1692.97 84.03 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 84.03 0.00 0.00 0.00
Cooling 138.07 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.18 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 286.79 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 465.34 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1692.97 84.03 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB -17.90 0.00 -17.90 Wetbulb [C] 2.50 180.00
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 33.90 14.80 15.00 Wetbulb [C] 3.60 30.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.67 83.67 39.40
Exterior Lighting Total 2508.33           39.40



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3419.77 2731.22 688.55 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   3304.49 2639.15 665.34 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   8629.62 6892.09 1737.53 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   2319.27 1852.29 466.97 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1926.64 1538.72 387.92 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1903.47 1520.22 383.25 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1995.40 1593.63 401.76 0.80 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2056.47 1642.41 414.06 0.80 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   9343.68 7462.38 1881.30 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   8949.36 7147.46 1801.91 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7802.80 6231.75 1571.05 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   6688.75 5342.01 1346.74 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5465.22 4364.83 1100.39 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5424.87 4332.60 1092.27 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5827.43 4654.11 1173.32 0.80 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5849.43 4671.68 1177.75 0.80 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   6262.32 5001.43 1260.88 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   5901.14 4712.98 1188.16 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5592.45 4466.44 1126.01 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   4593.47 3668.60 924.87 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3703.13 2957.52 745.61 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3665.56 2927.52 738.04 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4599.95 3673.77 926.18 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4613.35 3684.48 928.87 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3257.9 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3148.1 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 8221.1 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2209.5 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1835.4 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1813.4 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1900.9 3.13 10.67 11.09 10.38
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1959.1 3.13 10.67 11.09 10.38
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 8901.3 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 8525.7 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7433.4 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 6372.1 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5206.5 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5168.0 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5551.5 3.13 10.67 11.09 10.38
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5572.5 3.13 10.67 11.09 10.38
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5965.8 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 5621.8 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5327.7 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4376.0 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3527.8 3.13 10.67 11.09 10.38
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3492.0 3.13 10.67 11.09 10.38
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4382.2 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4394.9 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   2691.84 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   2644.46 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   5028.11 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   2644.46 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1975.43 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1975.43 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1988.82 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   2104.98 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   5276.97 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   5248.86 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   5276.97 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   5248.86 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   3608.60 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   3608.60 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   3639.29 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   3639.29 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   4094.63 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   4081.50 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   4094.63 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   4081.50 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   3239.53 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   3239.53 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   3251.41 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   3251.41 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.21 231.40 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 223.60 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.52 583.93 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 156.93 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.12 130.37 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.11 128.80 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.12 135.02 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.12 139.15 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.56 632.25 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.54 605.57 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.47 527.98 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.40 452.60 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 369.81 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 367.08 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.35 394.32 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.35 395.81 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.38 423.74 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.36 399.30 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 378.42 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 310.82 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.22 250.58 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.22 248.03 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 311.26 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 312.17 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1784.54 2141.45 0.172 0.207 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 31.09 0.00543
G NW APARTMENT 1724.39 2069.26 0.166 0.200 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 30.35 0.00543
OFFICE 4404.30 5285.16 0.434 0.521 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:00:00 25.76 0.00543
G NE APARTMENT 1210.26 1452.32 0.117 0.140 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 29.24 0.00543
G N1 APARTMENT 1005.37 1206.44 0.097 0.116 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 28.68 0.00543
G N2 APARTMENT 993.28 1191.94 0.096 0.115 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 28.68 0.00543
G S1 APARTMENT 1041.26 1249.51 0.100 0.121 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 33.71 0.00543
G S2 APARTMENT 1073.13 1287.75 0.104 0.124 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 33.53 0.00543
M SW APARTMENT 4875.86 5851.03 0.470 0.564 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 31.09 0.00543
M NW APARTMENT 4670.07 5604.09 0.451 0.541 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 30.35 0.00543
M SE APARTMENT 4071.80 4886.16 0.393 0.471 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 33.53 0.00543
M NE APARTMENT 3490.41 4188.49 0.337 0.404 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 29.24 0.00543
M N1 APARTMENT 2851.90 3422.28 0.275 0.330 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 28.68 0.00543
M N2 APARTMENT 2830.85 3397.02 0.273 0.328 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 28.68 0.00543
M S1 APARTMENT 3040.94 3649.13 0.293 0.352 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 33.71 0.00543
M S2 APARTMENT 3052.43 3662.91 0.294 0.353 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 33.71 0.00543
T SW APARTMENT 3267.95 3921.54 0.315 0.378 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 32.42 0.00543
T NW APARTMENT 3079.44 3695.33 0.297 0.356 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 31.09 0.00543
T SE APARTMENT 2918.39 3502.07 0.282 0.338 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 33.71 0.00543
T NE APARTMENT 2397.08 2876.49 0.231 0.277 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 33.90 0.00543
T N1 APARTMENT 1932.41 2318.89 0.186 0.224 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 30.35 0.00543
T N2 APARTMENT 1912.82 2295.39 0.185 0.221 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 33.68 0.00543
T S1 APARTMENT 2400.42 2880.50 0.232 0.278 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 33.90 0.00543
T S2 APARTMENT 2407.41 2888.90 0.232 0.279 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 33.90 0.00543


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1391.64 1669.97 0.049 0.059 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G NW APARTMENT 1382.67 1659.20 0.049 0.059 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
OFFICE 3041.32 3649.58 0.104 0.125 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G NE APARTMENT 1382.67 1659.20 0.049 0.059 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G N1 APARTMENT 816.90 980.28 0.029 0.035 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G N2 APARTMENT 816.90 980.28 0.029 0.035 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G S1 APARTMENT 828.22 993.87 0.029 0.035 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
G S2 APARTMENT 926.45 1111.74 0.033 0.039 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -17.90 0.00096
M SW APARTMENT 2755.28 3306.34 0.098 0.117 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M NW APARTMENT 2731.51 3277.81 0.097 0.116 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M SE APARTMENT 2755.28 3306.34 0.098 0.117 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M NE APARTMENT 2731.51 3277.81 0.097 0.116 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M N1 APARTMENT 1344.39 1613.27 0.048 0.057 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M N2 APARTMENT 1344.39 1613.27 0.048 0.057 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M S1 APARTMENT 1370.35 1644.41 0.049 0.058 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
M S2 APARTMENT 1370.35 1644.41 0.049 0.058 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T SW APARTMENT 2609.04 3130.85 0.092 0.111 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T NW APARTMENT 2597.94 3117.53 0.092 0.111 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T SE APARTMENT 2609.04 3130.85 0.092 0.111 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T NE APARTMENT 2597.94 3117.53 0.092 0.111 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T N1 APARTMENT 1885.90 2263.08 0.067 0.080 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T N2 APARTMENT 1885.90 2263.08 0.067 0.080 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T S1 APARTMENT 1895.96 2275.15 0.067 0.081 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096
T S2 APARTMENT 1895.96 2275.15 0.067 0.081 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -17.90 0.00096


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.21 0.21 0.06 0.06
SPLIT GNW 0.20 0.20 0.06 0.06
SPLIT OFFICE 0.52 0.52 0.13 0.13
SPLIT GNE 0.14 0.14 0.06 0.06
SPLIT GN1 0.12 0.12 0.03 0.03
SPLIT GN2 0.11 0.11 0.03 0.03
SPLIT GS1 0.12 0.12 0.04 0.04
SPLIT GS2 0.12 0.12 0.04 0.04
SPLIT MSW 0.56 0.56 0.12 0.12
SPLIT MNW 0.54 0.54 0.12 0.12
SPLIT MSE 0.47 0.47 0.12 0.12
SPLIT MNE 0.40 0.40 0.12 0.12
SPLIT MN1 0.33 0.33 0.06 0.06
SPLIT MN2 0.33 0.33 0.06 0.06
SPLIT MS1 0.35 0.35 0.06 0.06
SPLIT MS2 0.35 0.35 0.06 0.06
SPLIT TSW 0.38 0.38 0.11 0.11
SPLIT TNW 0.36 0.36 0.11 0.11
SPLIT TSE 0.34 0.34 0.11 0.11
SPLIT TNE 0.28 0.28 0.11 0.11
SPLIT TN1 0.22 0.22 0.08 0.08
SPLIT TN2 0.22 0.22 0.08 0.08
SPLIT TS1 0.28 0.28 0.08 0.08
SPLIT TS2 0.28 0.28 0.08 0.08



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 1808.25 6003.75 711.25
G NW APARTMENT 2130.25 6229.75 1242.25
OFFICE 164.50 1552.00 115.00
G NE APARTMENT 2207.25 6243.75 1242.00
G N1 APARTMENT 1507.50 6372.25 796.75
G N2 APARTMENT 1509.25 6373.50 795.50
G S1 APARTMENT 1287.50 6109.25 395.50
G S2 APARTMENT 1320.25 6135.00 455.50
M SW APARTMENT 2164.75 3712.75 146.25
M NW APARTMENT 2060.00 5043.75 348.50
M SE APARTMENT 2224.50 3749.75 155.75
M NE APARTMENT 2106.75 5057.50 349.00
M N1 APARTMENT 1576.75 5007.00 151.00
M N2 APARTMENT 1579.50 5006.25 151.00
M S1 APARTMENT 1737.75 3264.75 35.25
M S2 APARTMENT 1742.75 3273.25 35.50
T SW APARTMENT 3346.50 4693.00 1089.25
T NW APARTMENT 3541.00 5469.25 1678.50
T SE APARTMENT 3371.75 4678.25 1104.25
T NE APARTMENT 3607.75 5502.50 1705.25
T N1 APARTMENT 3043.25 5563.50 1346.75
T N2 APARTMENT 3047.50 5561.00 1350.25
T S1 APARTMENT 2813.00 4617.50 763.25
T S2 APARTMENT 2814.75 4609.25 761.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 4616.25 6499.25 1939.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 5.00 0.00 5.00 0.00
G NW APARTMENT 5.50 0.50 5.50 0.50
OFFICE 7.25 0.75 0.00 0.00
G NE APARTMENT 7.50 0.00 7.50 0.00
G N1 APARTMENT 7.00 0.00 7.00 0.00
G N2 APARTMENT 6.25 0.00 6.25 0.00
G S1 APARTMENT 1.00 0.00 1.00 0.00
G S2 APARTMENT 1.25 0.00 1.25 0.00
M SW APARTMENT 0.75 0.00 0.75 0.00
M NW APARTMENT 2.75 0.00 2.75 0.00
M SE APARTMENT 1.50 0.00 1.50 0.00
M NE APARTMENT 2.25 0.00 2.25 0.00
M N1 APARTMENT 0.25 0.00 0.25 0.00
M N2 APARTMENT 0.75 0.00 0.75 0.00
M S1 APARTMENT 0.00 0.00 0.00 0.00
M S2 APARTMENT 0.00 0.00 0.00 0.00
T SW APARTMENT 0.00 0.25 0.00 0.25
T NW APARTMENT 0.00 1.00 0.00 1.00
T SE APARTMENT 0.25 0.00 0.25 0.00
T NE APARTMENT 0.25 0.25 0.25 0.25
T N1 APARTMENT 4.00 0.00 4.00 0.00
T N2 APARTMENT 3.00 0.00 3.00 0.00
T S1 APARTMENT 1.75 0.00 1.75 0.00
T S2 APARTMENT 1.75 0.00 1.75 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 55.25 2.75 48.00 2.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.365 0.098 0.000 0.070
G NW APARTMENT 1.71 2.50 268.97 0.351 0.098 0.000 0.067
OFFICE 0.94 1.00 268.97 0.516 0.102 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.351 0.098 0.000 0.067
G N1 APARTMENT 1.71 2.50 268.97 0.351 0.059 0.000 0.066
G N2 APARTMENT 1.71 2.50 268.97 0.351 0.059 0.000 0.066
G S1 APARTMENT 1.71 2.50 268.97 0.352 0.059 0.000 0.069
G S2 APARTMENT 1.71 2.50 268.97 0.352 0.059 0.000 0.069
M SW APARTMENT 1.71 2.50 268.97 0.352 0.142 0.000 0.085
M NW APARTMENT 1.71 2.50 268.97 0.352 0.141 0.000 0.082
M SE APARTMENT 1.71 2.50 268.97 0.352 0.142 0.000 0.085
M NE APARTMENT 1.71 2.50 268.97 0.352 0.141 0.000 0.082
M N1 APARTMENT 1.71 2.50 268.97 0.352 0.085 0.000 0.082
M N2 APARTMENT 1.71 2.50 268.97 0.352 0.085 0.000 0.082
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.085
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.085 0.000 0.085
T SW APARTMENT 1.71 2.50 268.97 0.352 0.187 0.000 0.102
T NW APARTMENT 1.71 2.50 268.97 0.352 0.187 0.000 0.099
T SE APARTMENT 1.71 2.50 268.97 0.352 0.187 0.000 0.102
T NE APARTMENT 1.71 2.50 268.97 0.352 0.187 0.000 0.099
T N1 APARTMENT 1.71 2.50 268.97 0.352 0.113 0.000 0.098
T N2 APARTMENT 1.71 2.50 268.97 0.352 0.113 0.000 0.098
T S1 APARTMENT 1.71 2.50 268.97 0.352 0.113 0.000 0.102
T S2 APARTMENT 1.71 2.50 268.97 0.352 0.113 0.000 0.102
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.356 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.504 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.376 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.371 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.376 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.372 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.372 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.372 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.377 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.377 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1509.60 21479.23 09-JAN-03:30 92107.98 14-JUN-18:00
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 414.94 0.00 01-JAN-00:15 32646.39 16-JAN-08:00
WaterSystems:Electricity 414.94 0.00 01-JAN-00:15 32646.39 16-JAN-08:00
Water Heater:WaterSystems:Electricity 414.94 0.00 01-JAN-00:15 32646.39 16-JAN-08:00
Fans:Electricity 255.72 8108.93 01-JAN-07:15 8108.93 01-JAN-08:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
ElectricityPurchased:Plant 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
Cogeneration:ElectricityPurchased 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
ElectricityNet:Plant 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
Cogeneration:ElectricityNet 1509.60 21479.23 01-JAN-03:15 92107.98 14-JUN-18:00
ExteriorLights:Electricity 39.40 0.00 01-JAN-07:30 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.40 0.00 01-JAN-07:30 2508.33 01-JAN-00:15
Electricity:HVAC 378.84 8108.93 01-JAN-07:15 32242.10 26-JUN-17:15
General:Fans:Electricity 255.72 8108.93 01-JAN-07:15 8108.93 01-JAN-08:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 123.12 0.00 01-JAN-00:15 24133.17 26-JUN-17:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 218.92 0.00 09-JAN-11:45 96671.03 22-DEC-04:00
Gas:HVAC 218.92 0.00 09-JAN-11:45 96671.03 22-DEC-04:00
Heating:Gas 218.92 0.00 09-JAN-11:45 96671.03 22-DEC-04:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1212.75 2802.72 18-APR-07:30 149595.29 26-JUN-17:15
EnergyTransfer:Building 561.24 1775.27 28-APR-15:00 65192.92 26-JUN-17:15
EnergyTransfer:Zone:G SW APARTMENT 12.08 0.05 01-JUN-01:30 2122.67 16-AUG-16:30
Heating:EnergyTransfer 91.83 0.00 09-JAN-19:15 49979.49 22-DEC-04:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 2.99 0.00 01-JAN-08:30 1665.98 19-MAR-08:00
Cooling:EnergyTransfer 469.41 0.00 05-FEB-07:30 65192.92 26-JUN-17:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 9.10 0.00 01-JAN-00:15 2122.67 16-AUG-16:30
EnergyTransfer:Zone:G NW APARTMENT 11.14 0.02 17-FEB-12:15 1949.02 26-JUN-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 5.00 0.00 01-JAN-15:00 1678.86 19-MAR-08:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 6.14 0.00 01-JAN-00:15 1949.02 26-JUN-17:30
EnergyTransfer:Zone:OFFICE 22.57 0.02 08-DEC-13:45 3485.12 28-SEP-12:45
Heating:EnergyTransfer:Zone:OFFICE 0.41 0.00 01-JAN-00:15 3455.40 24-DEC-07:15
Cooling:EnergyTransfer:Zone:OFFICE 22.16 0.00 03-JAN-07:45 3485.12 28-SEP-12:45
EnergyTransfer:Zone:G NE APARTMENT 11.44 0.00 18-NOV-22:00 1693.75 21-DEC-23:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 4.82 0.00 01-JAN-10:00 1693.75 21-DEC-23:15
Cooling:EnergyTransfer:Zone:G NE APARTMENT 6.62 0.00 01-JAN-00:15 1401.41 26-JUN-18:15
EnergyTransfer:Zone:G N1 APARTMENT 7.91 0.02 19-MAY-16:00 1122.30 26-JUN-18:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 2.18 0.00 01-JAN-16:15 986.17 22-DEC-04:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 5.72 0.00 01-JAN-00:15 1122.30 26-JUN-18:30
EnergyTransfer:Zone:G N2 APARTMENT 7.92 0.07 09-MAR-14:15 1110.20 26-JUN-18:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 2.19 0.00 01-JAN-16:15 987.12 22-DEC-04:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 5.74 0.00 01-JAN-00:15 1110.20 26-JUN-18:30
EnergyTransfer:Zone:G S1 APARTMENT 10.13 0.01 19-MAY-15:15 1471.60 28-SEP-13:00
Heating:EnergyTransfer:Zone:G S1 APARTMENT 1.04 0.00 01-JAN-00:15 943.06 19-MAR-08:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 9.10 0.00 01-JAN-03:00 1471.60 28-SEP-13:00
EnergyTransfer:Zone:G S2 APARTMENT 10.06 0.02 13-MAY-07:00 1461.99 28-SEP-13:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 1.20 0.00 01-JAN-00:15 1025.33 22-DEC-04:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 8.86 0.00 01-JAN-02:30 1461.99 28-SEP-13:00
EnergyTransfer:Zone:M SW APARTMENT 43.66 0.40 01-MAY-13:00 5656.73 16-AUG-16:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 2.09 0.00 01-JAN-00:15 3076.07 22-DEC-04:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 41.57 0.00 04-JAN-16:00 5656.73 16-AUG-16:30
EnergyTransfer:Zone:M NW APARTMENT 31.82 0.11 15-NOV-15:45 5366.42 26-JUN-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 4.89 0.00 01-JAN-09:45 3472.60 21-DEC-23:15
Cooling:EnergyTransfer:Zone:M NW APARTMENT 26.93 0.00 01-JAN-00:15 5366.42 26-JUN-17:30
EnergyTransfer:Zone:M SE APARTMENT 45.24 0.56 13-DEC-03:00 4920.99 28-SEP-13:15
Heating:EnergyTransfer:Zone:M SE APARTMENT 2.15 0.00 01-JAN-00:15 3125.58 22-DEC-04:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 43.10 0.00 04-JAN-15:45 4920.99 28-SEP-13:15
EnergyTransfer:Zone:M NE APARTMENT 33.54 0.03 18-APR-09:00 4133.23 26-JUN-18:15
Heating:EnergyTransfer:Zone:M NE APARTMENT 4.87 0.00 01-JAN-08:15 3585.77 21-DEC-23:15
Cooling:EnergyTransfer:Zone:M NE APARTMENT 28.67 0.00 01-JAN-00:15 4133.23 26-JUN-18:15
EnergyTransfer:Zone:M N1 APARTMENT 28.00 0.30 13-APR-13:15 3340.88 26-JUN-18:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 1.12 0.00 01-JAN-00:15 1753.39 22-DEC-04:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 26.88 0.00 02-JAN-02:45 3340.88 26-JUN-18:30
EnergyTransfer:Zone:M N2 APARTMENT 28.02 0.10 27-APR-10:00 3319.14 26-JUN-18:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 1.12 0.00 01-JAN-00:15 1751.72 24-DEC-03:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 26.90 0.00 02-JAN-02:45 3319.14 26-JUN-18:30
EnergyTransfer:Zone:M S1 APARTMENT 43.49 3.39 03-APR-08:30 4425.15 11-OCT-13:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.35 0.00 01-JAN-00:15 1379.76 22-DEC-04:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 43.14 0.00 05-JAN-23:45 4425.15 11-OCT-13:30
EnergyTransfer:Zone:M S2 APARTMENT 43.50 0.46 05-FEB-07:45 4430.77 11-OCT-13:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.35 0.00 01-JAN-00:15 1383.20 22-DEC-04:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 43.15 0.00 05-JAN-23:45 4430.77 11-OCT-13:30
EnergyTransfer:Zone:T SW APARTMENT 25.18 0.01 17-DEC-22:45 3831.86 16-AUG-16:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 7.35 0.00 01-JAN-09:00 3140.69 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 17.82 0.00 01-JAN-00:15 3831.86 16-AUG-16:15
EnergyTransfer:Zone:T NW APARTMENT 22.58 0.00 17-DEC-20:45 3639.38 26-JUN-17:15
Heating:EnergyTransfer:Zone:T NW APARTMENT 10.41 0.00 01-JAN-14:30 3232.18 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 12.17 0.00 01-JAN-00:15 3639.38 26-JUN-17:15
EnergyTransfer:Zone:T SE APARTMENT 25.41 0.00 10-MAR-03:15 3399.13 16-AUG-13:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 7.21 0.00 01-JAN-08:30 3150.02 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 18.20 0.00 01-JAN-00:15 3399.13 16-AUG-13:00
EnergyTransfer:Zone:T NE APARTMENT 22.73 0.01 19-OCT-14:00 3244.81 21-DEC-23:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 10.13 0.00 01-JAN-10:00 3244.81 21-DEC-23:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 12.60 0.00 01-JAN-00:15 2795.54 26-JUN-17:15
EnergyTransfer:Zone:T N1 APARTMENT 16.87 0.01 12-MAR-13:45 2365.98 26-JUN-17:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 6.17 0.00 01-JAN-12:45 2294.33 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 10.69 0.00 01-JAN-00:15 2365.98 26-JUN-17:15
EnergyTransfer:Zone:T N2 APARTMENT 16.91 0.01 09-JAN-23:45 2344.00 26-JUN-17:15
Heating:EnergyTransfer:Zone:T N2 APARTMENT 6.19 0.00 01-JAN-12:30 2295.46 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 10.72 0.00 01-JAN-00:15 2344.00 26-JUN-17:15
EnergyTransfer:Zone:T S1 APARTMENT 20.51 0.12 21-MAY-02:30 2892.16 28-SEP-13:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 3.80 0.00 01-JAN-00:15 2196.41 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 16.70 0.00 01-JAN-01:15 2892.16 28-SEP-13:15
EnergyTransfer:Zone:T S2 APARTMENT 20.55 0.15 20-SEP-02:15 2901.94 28-SEP-13:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 3.81 0.00 01-JAN-00:15 2197.72 22-DEC-04:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 16.74 0.00 01-JAN-01:15 2901.94 28-SEP-13:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 651.51 0.00 23-MAR-16:15 84402.37 26-JUN-17:15
HeatingCoils:EnergyTransfer 175.13 0.00 09-JAN-11:45 77336.83 22-DEC-04:00
CoolingCoils:EnergyTransfer 476.37 0.00 01-JAN-00:15 84402.37 26-JUN-17:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 2.987 -9.095 0.000 0.000 3.816 2.413 12.213 17.077 0.000 0.140 0.000 0.000 -8.315 0.000 -3.702 -17.533
G NW APARTMENT 4.995 -6.141 0.000 0.000 3.853 2.413 12.213 7.762 0.000 0.139 0.000 0.000 -8.440 0.000 -3.585 -13.208
OFFICE 0.412 -22.160 0.000 0.000 0.524 21.914 7.534 17.557 0.000 0.130 0.001 0.000 -8.017 0.000 -2.937 -14.957
G NE APARTMENT 4.822 -6.622 0.000 0.000 3.865 2.413 12.213 8.157 0.000 0.139 0.000 0.000 -8.276 0.000 -3.569 -13.140
G N1 APARTMENT 2.184 -5.724 0.000 0.000 3.866 2.413 12.213 2.665 0.000 0.093 0.000 0.000 -5.249 0.000 -2.368 -10.092
G N2 APARTMENT 2.185 -5.736 0.000 0.000 3.866 2.413 12.213 2.664 0.000 0.093 0.000 0.000 -5.248 0.000 -2.367 -10.083
G S1 APARTMENT 1.035 -9.098 0.000 0.000 3.819 2.413 12.213 12.027 0.000 0.094 0.000 0.000 -5.066 0.000 -2.492 -14.945
G S2 APARTMENT 1.198 -8.862 0.000 0.000 3.819 2.413 12.213 12.029 0.000 0.094 0.000 0.000 -5.058 0.000 -2.493 -15.352
M SW APARTMENT 2.090 -41.568 0.000 0.000 3.668 2.413 12.213 16.592 0.000 0.197 18.869 0.000 -9.111 0.000 -5.363 -0.000
M NW APARTMENT 4.888 -26.929 0.000 0.000 3.750 2.413 12.213 7.403 0.000 0.195 10.383 0.000 -9.106 0.000 -5.210 -0.000
M SE APARTMENT 2.149 -43.095 0.000 0.000 3.679 2.413 12.213 16.999 0.000 0.197 19.759 0.000 -8.960 0.000 -5.355 0.000
M NE APARTMENT 4.870 -28.673 0.000 0.000 3.767 2.413 12.213 7.782 0.000 0.195 11.528 0.000 -8.904 0.000 -5.190 -0.000
M N1 APARTMENT 1.119 -26.880 0.000 0.000 3.742 2.413 12.213 2.452 0.000 0.129 14.010 0.000 -5.736 0.000 -3.461 -0.000
M N2 APARTMENT 1.124 -26.896 0.000 0.000 3.743 2.413 12.213 2.451 0.000 0.129 14.015 0.000 -5.732 0.000 -3.460 -0.000
M S1 APARTMENT 0.347 -43.138 0.000 0.000 3.639 2.413 12.213 11.708 0.000 0.131 21.874 0.000 -5.595 0.000 -3.592 0.000
M S2 APARTMENT 0.350 -43.146 0.000 0.000 3.639 2.413 12.213 11.708 0.000 0.131 21.878 0.000 -5.594 0.000 -3.591 0.000
T SW APARTMENT 7.353 -17.822 0.000 0.000 3.763 2.413 12.213 16.485 0.000 0.255 0.000 0.000 -8.569 0.000 -6.831 -9.260
T NW APARTMENT 10.405 -12.172 0.000 0.000 3.805 2.413 12.213 7.319 0.000 0.253 0.000 0.000 -8.644 0.000 -6.689 -8.903
T SE APARTMENT 7.210 -18.196 0.000 0.000 3.770 2.413 12.213 16.892 0.000 0.255 0.000 0.000 -8.445 0.000 -6.834 -9.278
T NE APARTMENT 10.132 -12.595 0.000 0.000 3.818 2.413 12.213 7.724 0.000 0.253 0.000 0.000 -8.493 0.000 -6.680 -8.785
T N1 APARTMENT 6.175 -10.691 0.000 0.000 3.810 2.413 12.213 2.439 0.000 0.167 0.000 0.000 -5.401 0.000 -4.391 -6.731
T N2 APARTMENT 6.187 -10.718 0.000 0.000 3.810 2.413 12.213 2.436 0.000 0.167 0.000 0.000 -5.398 0.000 -4.392 -6.718
T S1 APARTMENT 3.804 -16.704 0.000 0.000 3.749 2.413 12.213 11.659 0.000 0.169 0.000 0.000 -5.260 0.000 -4.527 -7.516
T S2 APARTMENT 3.812 -16.741 0.000 0.000 3.749 2.413 12.213 11.656 0.000 0.169 0.000 0.000 -5.258 0.000 -4.527 -7.486
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.126 0.000 0.015 0.000 0.000 -1.007 0.000 -1.073 -15.131
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.455 0.000 0.494 0.000 0.000 -2.684 0.000 -18.816 -2.783
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.127 0.000 0.013 0.000 0.000 -1.109 0.000 -0.885 -15.216
Total Facility 91.833 -469.403 0.000 0.000 87.330 128.627 294.692 234.350 0.000 4.432 132.316 0.000 -172.674 0.000 -124.382 -207.121


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 16-AUG-16:30 0.00 -2123.13 0.00 0.00 84.75 144.04 588.62 2257.79 0.00 58.51 0.00 0.00 0.00 0.00 0.00 -1010.58
G NW APARTMENT 26-JUN-17:23 0.00 -1949.14 0.00 0.00 141.80 194.45 588.62 2136.83 0.00 85.43 0.00 0.00 0.00 0.00 0.00 -1198.00
OFFICE 28-SEP-12:45 0.00 -3484.96 0.00 0.00 67.31 1622.34 544.92 2573.06 0.00 10.12 0.00 0.00 0.00 0.00 0.00 -1332.79
G NE APARTMENT 26-JUN-18:15 0.00 -1401.36 0.00 0.00 141.81 230.46 547.42 843.49 0.00 73.38 0.00 0.00 0.00 0.00 0.00 -435.20
G N1 APARTMENT 26-JUN-18:30 0.00 -1122.27 0.00 0.00 141.81 230.46 547.42 660.00 0.00 47.41 0.00 0.00 0.00 0.00 0.00 -504.83
G N2 APARTMENT 26-JUN-18:30 0.00 -1110.17 0.00 0.00 141.81 230.46 547.42 660.19 0.00 47.41 0.00 0.00 0.00 0.00 0.00 -517.12
G S1 APARTMENT 28-SEP-13:00 0.00 -1471.49 0.00 0.00 40.75 28.81 388.49 2288.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1274.87
G S2 APARTMENT 28-SEP-13:00 0.00 -1461.89 0.00 0.00 40.75 28.81 388.49 2288.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1284.62
M SW APARTMENT 16-AUG-16:23 0.00 -5657.32 0.00 0.00 84.75 144.04 588.62 2247.72 0.00 83.94 2508.25 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 26-JUN-17:23 0.00 -5366.32 0.00 0.00 141.80 194.45 588.62 2121.48 0.00 122.58 2197.38 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 28-SEP-13:15 0.00 -4920.71 0.00 0.00 40.75 28.81 382.60 2412.58 0.00 17.44 2038.52 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 26-JUN-18:15 0.00 -4133.06 0.00 0.00 141.81 230.46 547.42 832.43 0.00 105.29 2275.65 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 26-JUN-18:30 0.00 -3340.75 0.00 0.00 141.81 230.46 547.42 651.60 0.00 68.02 1701.45 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 26-JUN-18:30 0.00 -3319.02 0.00 0.00 141.81 230.46 547.42 651.72 0.00 68.02 1679.60 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 11-OCT-13:30 0.00 -4424.90 0.00 0.00 40.75 28.81 382.60 2189.98 0.00 82.08 1700.68 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 11-OCT-13:30 0.00 -4430.52 0.00 0.00 40.75 28.81 382.60 2189.94 0.00 82.08 1706.35 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 16-AUG-16:13 0.00 -3832.96 0.00 0.00 84.75 144.04 588.62 2241.87 0.00 98.04 675.64 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 26-JUN-17:06 0.00 -3640.30 0.00 0.00 141.81 194.45 588.62 2130.78 0.00 178.67 405.96 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 16-AUG-13:00 0.00 -3398.16 0.00 0.00 40.75 28.81 388.49 1894.33 0.00 152.79 892.99 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 26-JUN-17:06 0.00 -2796.49 0.00 0.00 141.81 194.45 588.62 812.25 0.00 178.67 880.69 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 26-JUN-17:06 0.00 -2367.03 0.00 0.00 141.81 194.45 588.62 580.40 0.00 107.77 753.98 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 26-JUN-17:06 0.00 -2345.05 0.00 0.00 141.81 194.45 588.62 580.69 0.00 107.77 731.71 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 28-SEP-13:15 0.00 -2891.99 0.00 0.00 40.75 28.81 382.60 2172.27 0.00 13.83 253.73 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 28-SEP-13:15 0.00 -2901.78 0.00 0.00 40.75 28.81 382.60 2172.13 0.00 13.83 263.66 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 26-JUN-17:12 0.00 -65205.48 0.00 0.00 3261.57 6475.86 14071.03 22643.51 0.00 3064.21 15689.30 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 19-MAR-07:55 1666.58 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -993.73 0.00 -742.24 -436.29
G NW APARTMENT 19-MAR-07:50 1679.05 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -991.30 0.00 -742.24 -451.18
OFFICE 26-DEC-07:01 4749.39 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -372.89 0.00 -107.81 -4843.25
G NE APARTMENT 21-DEC-23:15 1693.79 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1020.07 0.00 -609.87 -630.94
G N1 APARTMENT 01-MAY-06:01 1527.23 0.00 0.00 0.00 163.29 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -60.45 0.00 -95.58 -2010.72
G N2 APARTMENT 01-MAY-06:01 1534.67 0.00 0.00 0.00 163.30 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -60.46 0.00 -95.58 -2018.16
G S1 APARTMENT 23-OCT-07:01 1223.32 0.00 0.00 0.00 74.07 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -363.61 0.00 -88.43 -1277.06
G S2 APARTMENT 01-MAY-06:01 1486.20 0.00 0.00 0.00 163.22 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -107.69 0.00 -95.58 -1922.38
M SW APARTMENT 22-DEC-04:00 3076.06 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1140.54 0.00 -659.39 -1703.88
M NW APARTMENT 21-DEC-23:15 3472.68 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1025.94 0.00 -876.87 -2136.95
M SE APARTMENT 22-DEC-04:00 3125.57 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1123.87 0.00 -659.39 -1770.06
M NE APARTMENT 21-DEC-23:15 3585.86 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1040.51 0.00 -876.87 -2235.57
M N1 APARTMENT 05-MAR-07:06 2008.99 0.00 0.00 0.00 161.22 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -414.06 0.00 -129.71 -2102.67
M N2 APARTMENT 02-FEB-08:01 2446.15 0.00 0.00 0.00 74.11 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -356.77 0.00 -133.45 -2461.75
M S1 APARTMENT 19-DEC-22:06 1933.45 0.00 0.00 0.00 189.67 86.42 417.92 0.00 0.00 0.00 0.00 0.00 -612.43 0.00 -304.10 -1710.93
M S2 APARTMENT 19-DEC-22:06 1934.69 0.00 0.00 0.00 189.67 86.42 417.92 0.00 0.00 0.00 0.00 0.00 -612.42 0.00 -304.10 -1712.19
T SW APARTMENT 22-DEC-04:00 3140.68 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1113.59 0.00 -872.97 -1581.87
T NW APARTMENT 22-DEC-04:00 3232.17 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1084.22 0.00 -872.97 -1702.73
T SE APARTMENT 22-DEC-04:00 3150.01 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1096.44 0.00 -872.97 -1608.35
T NE APARTMENT 21-DEC-23:00 3244.86 0.00 0.00 0.00 189.67 86.42 417.92 0.00 0.00 0.00 0.00 0.00 -1004.41 0.00 -1264.52 -1669.95
T N1 APARTMENT 22-DEC-04:00 2294.32 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -648.97 0.00 -526.57 -1546.53
T N2 APARTMENT 22-DEC-04:00 2295.46 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -648.95 0.00 -526.57 -1547.68
T S1 APARTMENT 22-DEC-04:00 2196.41 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -678.35 0.00 -526.57 -1419.23
T S2 APARTMENT 22-DEC-04:00 2197.71 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -678.33 0.00 -526.57 -1420.56
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 22-DEC-04:00 49446.11 0.00 0.00 0.00 4362.44 2334.74 5313.65 0.00 0.00 0.00 0.00 0.00 -21661.06 0.00 -13038.80 -26757.08



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Sec1.1A-General Information

Data
Weather File Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 48.00
Number of hours cooling loads not met 2.00
Number of hours not met 50.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 8572.78 0.00 0.00 0.00 0.00
Exterior Lighting 39.40 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 218.92 96671.03 0.00 0.00
Space Cooling 123.12 19196.01 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 255.72 8108.93 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 414.94 29773.86 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 26456.41 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1509.60   218.92   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1509.60
Natural Gas 0.00 218.92
Additional 0.00 0.00
Total 511.42 1728.52


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 39.28
Fans-Interior 81.58
Service Water Heating 132.37
Receptacle Equipment 163.15
Miscellaneous 12.57
Subtotal 481.59


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 69.84
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 69.84


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 9.55
Space Heating 12.66
Space Cooling 7.12
Fans-Interior 14.79
Service Water Heating 24.01
Receptacle Equipment 29.59
Miscellaneous 2.28



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.206588
G NW APARTMENT DIRECT AIR 0.199625
OFFICE DIRECT AIR 0.521315
G NE APARTMENT DIRECT AIR 0.140107
G N1 APARTMENT DIRECT AIR 0.116388
G N2 APARTMENT DIRECT AIR 0.114989
G S1 APARTMENT DIRECT AIR 0.120542
G S2 APARTMENT DIRECT AIR 0.124231
M SW APARTMENT DIRECT AIR 0.564452
M NW APARTMENT DIRECT AIR 0.540631
M SE APARTMENT DIRECT AIR 0.471367
M NE APARTMENT DIRECT AIR 0.404067
M N1 APARTMENT DIRECT AIR 0.330154
M N2 APARTMENT DIRECT AIR 0.327716
M S1 APARTMENT DIRECT AIR 0.352035
M S2 APARTMENT DIRECT AIR 0.353364
T SW APARTMENT DIRECT AIR 0.378307
T NW APARTMENT DIRECT AIR 0.356488
T SE APARTMENT DIRECT AIR 0.337840
T NE APARTMENT DIRECT AIR 0.277491
T N1 APARTMENT DIRECT AIR 0.223706
T N2 APARTMENT DIRECT AIR 0.221436
T S1 APARTMENT DIRECT AIR 0.277883
T S2 APARTMENT DIRECT AIR 0.278693


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.206588
SPLIT GNW MAIN BRANCH 0.199625
SPLIT OFFICE MAIN BRANCH 0.521315
SPLIT GNE MAIN BRANCH 0.140107
SPLIT GN1 MAIN BRANCH 0.116388
SPLIT GN2 MAIN BRANCH 0.114989
SPLIT GS1 MAIN BRANCH 0.120542
SPLIT GS2 MAIN BRANCH 0.124231
SPLIT MSW MAIN BRANCH 0.564452
SPLIT MNW MAIN BRANCH 0.540631
SPLIT MSE MAIN BRANCH 0.471367
SPLIT MNE MAIN BRANCH 0.404067
SPLIT MN1 MAIN BRANCH 0.330154
SPLIT MN2 MAIN BRANCH 0.327716
SPLIT MS1 MAIN BRANCH 0.352035
SPLIT MS2 MAIN BRANCH 0.353364
SPLIT TSW MAIN BRANCH 0.378307
SPLIT TNW MAIN BRANCH 0.356488
SPLIT TSE MAIN BRANCH 0.337840
SPLIT TNE MAIN BRANCH 0.277491
SPLIT TN1 MAIN BRANCH 0.223706
SPLIT TN2 MAIN BRANCH 0.221436
SPLIT TS1 MAIN BRANCH 0.277883
SPLIT TS2 MAIN BRANCH 0.278693


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.206588
SPLIT GNW 0.199625
SPLIT OFFICE 0.521315
SPLIT GNE 0.140107
SPLIT GN1 0.116388
SPLIT GN2 0.114989
SPLIT GS1 0.120542
SPLIT GS2 0.124231
SPLIT MSW 0.564452
SPLIT MNW 0.540631
SPLIT MSE 0.471367
SPLIT MNE 0.404067
SPLIT MN1 0.330154
SPLIT MN2 0.327716
SPLIT MS1 0.352035
SPLIT MS2 0.353364
SPLIT TSW 0.378307
SPLIT TNW 0.356488
SPLIT TSE 0.337840
SPLIT TNE 0.277491
SPLIT TN1 0.223706
SPLIT TN2 0.221436
SPLIT TS1 0.277883
SPLIT TS2 0.278693


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.206588 0.026898
SPLIT GNW OA CONTROLLER 0.199625 0.025953
SPLIT OFFICE OA CONTROLLER 0.521315 0.038104
SPLIT GNE OA CONTROLLER 0.140107 0.025953
SPLIT GN1 OA CONTROLLER 0.116388 0.025953
SPLIT GN2 OA CONTROLLER 0.114989 0.025953
SPLIT GS1 OA CONTROLLER 0.120542 0.025953
SPLIT GS2 OA CONTROLLER 0.124231 0.025953
SPLIT MSW OA CONTROLLER 0.564452 0.051906
SPLIT MNW OA CONTROLLER 0.540631 0.051906
SPLIT MSE OA CONTROLLER 0.471367 0.051906
SPLIT MNE OA CONTROLLER 0.404067 0.051906
SPLIT MN1 OA CONTROLLER 0.330154 0.051906
SPLIT MN2 OA CONTROLLER 0.327716 0.051906
SPLIT MS1 OA CONTROLLER 0.352035 0.051906
SPLIT MS2 OA CONTROLLER 0.353364 0.051906
SPLIT TSW OA CONTROLLER 0.378307 0.025953
SPLIT TNW OA CONTROLLER 0.356488 0.025953
SPLIT TSE OA CONTROLLER 0.337840 0.025953
SPLIT TNE OA CONTROLLER 0.277491 0.025953
SPLIT TN1 OA CONTROLLER 0.223706 0.025953
SPLIT TN2 OA CONTROLLER 0.221436 0.025953
SPLIT TS1 OA CONTROLLER 0.277883 0.025953
SPLIT TS2 OA CONTROLLER 0.278693 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.206588 3419.77 0.798655
SPLIT GNW COOLING COIL 0.199625 3304.49 0.798655
SPLIT OFFICE COOLING COIL 0.521315 8629.62 0.798655
SPLIT GNE COOLING COIL 0.140107 2319.27 0.798655
SPLIT GN1 COOLING COIL 0.116388 1926.64 0.798655
SPLIT GN2 COOLING COIL 0.114989 1903.47 0.798655
SPLIT GS1 COOLING COIL 0.120542 1995.40 0.798655
SPLIT GS2 COOLING COIL 0.124231 2056.47 0.798655
SPLIT MSW COOLING COIL 0.564452 9343.68 0.798655
SPLIT MNW COOLING COIL 0.540631 8949.36 0.798655
SPLIT MSE COOLING COIL 0.471367 7802.80 0.798655
SPLIT MNE COOLING COIL 0.404067 6688.75 0.798655
SPLIT MN1 COOLING COIL 0.330154 5465.22 0.798655
SPLIT MN2 COOLING COIL 0.327716 5424.87 0.798655
SPLIT MS1 COOLING COIL 0.352035 5827.43 0.798655
SPLIT MS2 COOLING COIL 0.353364 5849.43 0.798655
SPLIT TSW COOLING COIL 0.378307 6262.32 0.798655
SPLIT TNW COOLING COIL 0.356488 5901.14 0.798655
SPLIT TSE COOLING COIL 0.337840 5592.45 0.798655
SPLIT TNE COOLING COIL 0.277491 4593.47 0.798655
SPLIT TN1 COOLING COIL 0.223706 3703.13 0.798655
SPLIT TN2 COOLING COIL 0.221436 3665.56 0.798655
SPLIT TS1 COOLING COIL 0.277883 4599.95 0.798655
SPLIT TS2 COOLING COIL 0.278693 4613.35 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.206588 0.206588 0.206588 0.206588 2691.84 3419.77 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.199625 0.199625 0.199625 0.199625 2644.46 3304.49 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.521315 0.521315 0.521315 0.521315 5028.11 8629.62 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.140107 0.140107 0.140107 0.140107 2644.46 2319.27 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.116388 0.116388 0.116388 0.116388 1975.43 1926.64 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.114989 0.114989 0.114989 0.114989 1975.43 1903.47 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.120542 0.120542 0.120542 0.120542 1988.82 1995.40 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.124231 0.124231 0.124231 0.124231 2104.98 2056.47 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.564452 0.564452 0.564452 0.564452 5276.97 9343.68 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.540631 0.540631 0.540631 0.540631 5248.86 8949.36 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.471367 0.471367 0.471367 0.471367 5276.97 7802.80 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.404067 0.404067 0.404067 0.404067 5248.86 6688.75 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.330154 0.330154 0.330154 0.330154 3608.60 5465.22 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.327716 0.327716 0.327716 0.327716 3608.60 5424.87 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.352035 0.352035 0.352035 0.352035 3639.29 5827.43 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.353364 0.353364 0.353364 0.353364 3639.29 5849.43 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.378307 0.378307 0.378307 0.378307 4094.63 6262.32 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.356488 0.356488 0.356488 0.356488 4081.50 5901.14 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.337840 0.337840 0.337840 0.337840 4094.63 5592.45 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.277491 0.277491 0.277491 0.277491 4081.50 4593.47 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.223706 0.223706 0.223706 0.223706 3239.53 3703.13 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.221436 0.221436 0.221436 0.221436 3239.53 3665.56 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.277883 0.277883 0.277883 0.277883 3251.41 4599.95 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.278693 0.278693 0.278693 0.278693 3251.41 4613.35 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.206588
SPLIT GNW SUPPLY FAN 0.199625
SPLIT OFFICE SUPPLY FAN 0.521315
SPLIT GNE SUPPLY FAN 0.140107
SPLIT GN1 SUPPLY FAN 0.116388
SPLIT GN2 SUPPLY FAN 0.114989
SPLIT GS1 SUPPLY FAN 0.120542
SPLIT GS2 SUPPLY FAN 0.124231
SPLIT MSW SUPPLY FAN 0.564452
SPLIT MNW SUPPLY FAN 0.540631
SPLIT MSE SUPPLY FAN 0.471367
SPLIT MNE SUPPLY FAN 0.404067
SPLIT MN1 SUPPLY FAN 0.330154
SPLIT MN2 SUPPLY FAN 0.327716
SPLIT MS1 SUPPLY FAN 0.352035
SPLIT MS2 SUPPLY FAN 0.353364
SPLIT TSW SUPPLY FAN 0.378307
SPLIT TNW SUPPLY FAN 0.356488
SPLIT TSE SUPPLY FAN 0.337840
SPLIT TNE SUPPLY FAN 0.277491
SPLIT TN1 SUPPLY FAN 0.223706
SPLIT TN2 SUPPLY FAN 0.221436
SPLIT TS1 SUPPLY FAN 0.277883
SPLIT TS2 SUPPLY FAN 0.278693


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 2691.84
SPLIT GNW HEATING COIL 2644.46
SPLIT OFFICE HEATING COIL 5028.11
SPLIT GNE HEATING COIL 2644.46
SPLIT GN1 HEATING COIL 1975.43
SPLIT GN2 HEATING COIL 1975.43
SPLIT GS1 HEATING COIL 1988.82
SPLIT GS2 HEATING COIL 2104.98
SPLIT MSW HEATING COIL 5276.97
SPLIT MNW HEATING COIL 5248.86
SPLIT MSE HEATING COIL 5276.97
SPLIT MNE HEATING COIL 5248.86
SPLIT MN1 HEATING COIL 3608.60
SPLIT MN2 HEATING COIL 3608.60
SPLIT MS1 HEATING COIL 3639.29
SPLIT MS2 HEATING COIL 3639.29
SPLIT TSW HEATING COIL 4094.63
SPLIT TNW HEATING COIL 4081.50
SPLIT TSE HEATING COIL 4094.63
SPLIT TNE HEATING COIL 4081.50
SPLIT TN1 HEATING COIL 3239.53
SPLIT TN2 HEATING COIL 3239.53
SPLIT TS1 HEATING COIL 3251.41
SPLIT TS2 HEATING COIL 3251.41



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:29

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.26 0.85
February 22.18 -0.2
March 22.43 4.82
April 22.33 6.08
May 23.27 13.74
June 24.38 22.16
July 24.40 22.71
August 24.40 21.74
September 24.29 18.54
October 22.91 7.12
November 22.47 3.03
December 22.11 -1.0
     
Annual Sum or Average 23.12 10.02
Minimum of Months 22.11 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 0.85
February 21.77 -0.2
March 22.06 4.82
April 22.09 6.08
May 23.16 13.74
June 24.38 22.16
July 24.40 22.71
August 24.39 21.74
September 24.23 18.54
October 22.43 7.12
November 21.90 3.03
December 21.77 -1.0
     
Annual Sum or Average 22.87 10.02
Minimum of Months 21.77 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 0.85
February 21.40 -0.2
March 22.11 4.82
April 22.26 6.08
May 23.54 13.74
June 23.90 22.16
July 23.90 22.71
August 23.90 21.74
September 23.87 18.54
October 22.91 7.12
November 22.18 3.03
December 21.08 -1.0
     
Annual Sum or Average 22.74 10.02
Minimum of Months 21.08 -1.0
Maximum of Months 23.90 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 0.85
February 21.75 -0.2
March 22.00 4.82
April 22.05 6.08
May 23.06 13.74
June 24.37 22.16
July 24.39 22.71
August 24.39 21.74
September 24.21 18.54
October 22.33 7.12
November 21.85 3.03
December 21.74 -1.0
     
Annual Sum or Average 22.83 10.02
Minimum of Months 21.74 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 0.85
February 21.73 -0.2
March 21.92 4.82
April 21.95 6.08
May 22.91 13.74
June 24.37 22.16
July 24.39 22.71
August 24.39 21.74
September 24.24 18.54
October 22.29 7.12
November 21.83 3.03
December 21.74 -1.0
     
Annual Sum or Average 22.80 10.02
Minimum of Months 21.73 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 0.85
February 21.73 -0.2
March 21.91 4.82
April 21.95 6.08
May 22.91 13.74
June 24.37 22.16
July 24.39 22.71
August 24.39 21.74
September 24.24 18.54
October 22.28 7.12
November 21.83 3.03
December 21.74 -1.0
     
Annual Sum or Average 22.80 10.02
Minimum of Months 21.73 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.28 0.85
February 22.18 -0.2
March 22.39 4.82
April 22.24 6.08
May 23.10 13.74
June 24.37 22.16
July 24.39 22.71
August 24.40 21.74
September 24.31 18.54
October 22.95 7.12
November 22.49 3.03
December 22.14 -1.0
     
Annual Sum or Average 23.11 10.02
Minimum of Months 22.14 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.27 0.85
February 22.18 -0.2
March 22.39 4.82
April 22.25 6.08
May 23.11 13.74
June 24.37 22.16
July 24.39 22.71
August 24.40 21.74
September 24.31 18.54
October 22.95 7.12
November 22.49 3.03
December 22.14 -1.0
     
Annual Sum or Average 23.11 10.02
Minimum of Months 22.14 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.48 0.85
February 23.11 -0.2
March 23.17 4.82
April 23.35 6.08
May 24.30 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.38 18.54
October 23.78 7.12
November 23.52 3.03
December 22.82 -1.0
     
Annual Sum or Average 23.76 10.02
Minimum of Months 22.82 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.33 0.85
February 22.16 -0.2
March 22.73 4.82
April 23.05 6.08
May 24.28 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.35 18.54
October 23.46 7.12
November 22.55 3.03
December 21.98 -1.0
     
Annual Sum or Average 23.35 10.02
Minimum of Months 21.98 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.40 0.85
February 23.06 -0.2
March 23.16 4.82
April 23.31 6.08
May 24.29 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.37 18.54
October 23.74 7.12
November 23.45 3.03
December 22.76 -1.0
     
Annual Sum or Average 23.73 10.02
Minimum of Months 22.76 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 0.85
February 22.09 -0.2
March 22.66 4.82
April 22.98 6.08
May 24.24 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.34 18.54
October 23.39 7.12
November 22.40 3.03
December 21.89 -1.0
     
Annual Sum or Average 23.29 10.02
Minimum of Months 21.89 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.38 0.85
February 22.14 -0.2
March 22.72 4.82
April 23.14 6.08
May 24.32 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.37 18.54
October 23.57 7.12
November 22.61 3.03
December 22.00 -1.0
     
Annual Sum or Average 23.38 10.02
Minimum of Months 22.00 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.36 0.85
February 22.14 -0.2
March 22.72 4.82
April 23.14 6.08
May 24.32 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.37 18.54
October 23.56 7.12
November 22.59 3.03
December 21.99 -1.0
     
Annual Sum or Average 23.37 10.02
Minimum of Months 21.99 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.76 0.85
February 23.31 -0.2
March 23.34 4.82
April 23.54 6.08
May 24.34 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.39 18.54
October 23.91 7.12
November 23.75 3.03
December 23.12 -1.0
     
Annual Sum or Average 23.89 10.02
Minimum of Months 23.12 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.75 0.85
February 23.30 -0.2
March 23.34 4.82
April 23.54 6.08
May 24.34 13.74
June 24.40 22.16
July 24.40 22.71
August 24.40 21.74
September 24.39 18.54
October 23.91 7.12
November 23.74 3.03
December 23.12 -1.0
     
Annual Sum or Average 23.89 10.02
Minimum of Months 23.12 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 0.85
February 22.58 -0.2
March 22.80 4.82
April 22.80 6.08
May 23.95 13.74
June 24.39 22.16
July 24.40 22.71
August 24.40 21.74
September 24.24 18.54
October 23.12 7.12
November 22.84 3.03
December 22.35 -1.0
     
Annual Sum or Average 23.38 10.02
Minimum of Months 22.35 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 0.85
February 22.02 -0.2
March 22.52 4.82
April 22.62 6.08
May 23.90 13.74
June 24.39 22.16
July 24.39 22.71
August 24.39 21.74
September 24.17 18.54
October 22.83 7.12
November 22.25 3.03
December 21.92 -1.0
     
Annual Sum or Average 23.13 10.02
Minimum of Months 21.92 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 0.85
February 22.58 -0.2
March 22.81 4.82
April 22.82 6.08
May 23.94 13.74
June 24.39 22.16
July 24.39 22.71
August 24.40 21.74
September 24.23 18.54
October 23.11 7.12
November 22.81 3.03
December 22.34 -1.0
     
Annual Sum or Average 23.38 10.02
Minimum of Months 22.34 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 0.85
February 21.97 -0.2
March 22.47 4.82
April 22.61 6.08
May 23.84 13.74
June 24.39 22.16
July 24.39 22.71
August 24.39 21.74
September 24.14 18.54
October 22.79 7.12
November 22.16 3.03
December 21.87 -1.0
     
Annual Sum or Average 23.09 10.02
Minimum of Months 21.87 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 0.85
February 21.94 -0.2
March 22.46 4.82
April 22.60 6.08
May 23.92 13.74
June 24.39 22.16
July 24.39 22.71
August 24.39 21.74
September 24.17 18.54
October 22.79 7.12
November 22.15 3.03
December 21.87 -1.0
     
Annual Sum or Average 23.09 10.02
Minimum of Months 21.87 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 0.85
February 21.94 -0.2
March 22.46 4.82
April 22.60 6.08
May 23.91 13.74
June 24.39 22.16
July 24.39 22.71
August 24.39 21.74
September 24.16 18.54
October 22.79 7.12
November 22.15 3.03
December 21.86 -1.0
     
Annual Sum or Average 23.09 10.02
Minimum of Months 21.86 -1.0
Maximum of Months 24.39 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.78 0.85
February 22.67 -0.2
March 22.88 4.82
April 22.88 6.08
May 24.02 13.74
June 24.39 22.16
July 24.40 22.71
August 24.40 21.74
September 24.27 18.54
October 23.22 7.12
November 22.94 3.03
December 22.44 -1.0
     
Annual Sum or Average 23.45 10.02
Minimum of Months 22.44 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.78 0.85
February 22.67 -0.2
March 22.89 4.82
April 22.88 6.08
May 24.02 13.74
June 24.39 22.16
July 24.40 22.71
August 24.40 21.74
September 24.27 18.54
October 23.22 7.12
November 22.94 3.03
December 22.44 -1.0
     
Annual Sum or Average 23.45 10.02
Minimum of Months 22.44 -1.0
Maximum of Months 24.40 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.40 0.85
February 22.25 -0.2
March 23.10 4.82
April 23.36 6.08
May 25.45 13.74
June 26.87 22.16
July 26.92 22.71
August 26.81 21.74
September 26.16 18.54
October 23.72 7.12
November 22.81 3.03
December 21.79 -1.0
     
Annual Sum or Average 24.31 10.02
Minimum of Months 21.79 -1.0
Maximum of Months 26.92 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.73 0.85
February 20.50 -0.2
March 21.38 4.82
April 21.57 6.08
May 23.33 13.74
June 26.07 22.16
July 26.30 22.71
August 26.17 21.74
September 25.70 18.54
October 22.37 7.12
November 21.23 3.03
December 20.33 -1.0
     
Annual Sum or Average 22.99 10.02
Minimum of Months 20.33 -1.0
Maximum of Months 26.30 22.71



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.69 0.85
February 24.27 -0.2
March 24.79 4.82
April 25.07 6.08
May 26.51 13.74
June 27.05 22.16
July 27.06 22.71
August 27.02 21.74
September 26.85 18.54
October 25.69 7.12
November 24.85 3.03
December 23.94 -1.0
     
Annual Sum or Average 25.66 10.02
Minimum of Months 23.94 -1.0
Maximum of Months 27.06 22.71



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:29

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.123787E+12 76186.610 24-JAN-18:30 8572.775 26456.413 8108.927 0.000 3276.078 2508.330 0.000 0.000 0.000 0.000 0.000 27264.087 0.000 0.000 0.000
February 0.111660E+12 75266.471 18-FEB-18:15 8572.775 26456.413 8108.927 0.000 3683.691 2508.330 0.000 0.000 0.000 0.000 0.000 25936.335 0.000 0.000 0.000
March 0.124402E+12 78547.652 15-MAR-17:00 8572.775 26456.413 8108.927 0.000 7664.076 0.000 0.000 0.000 0.000 0.000 0.000 27745.460 0.000 0.000 0.000
April 0.117798E+12 74914.936 08-APR-17:15 8572.775 26456.413 8108.927 0.000 7183.001 0.000 0.000 0.000 0.000 0.000 0.000 24593.821 0.000 0.000 0.000
May 0.126566E+12 80163.307 17-MAY-17:30 8572.775 26456.413 8108.927 0.000 11177.337 0.000 0.000 0.000 0.000 0.000 0.000 25847.855 0.000 0.000 0.000
June 0.136067E+12 92107.982 14-JUN-17:00 8572.775 26456.413 8108.927 0.000 19196.011 0.000 0.000 0.000 0.000 0.000 0.000 29773.856 0.000 0.000 0.000
July 0.140370E+12 90061.562 18-JUL-17:45 8572.775 26456.413 8108.927 0.000 18005.172 0.000 0.000 0.000 0.000 0.000 0.000 28918.276 0.000 0.000 0.000
August 0.138780E+12 88694.714 25-AUG-17:00 8572.775 26456.413 8108.927 0.000 15857.507 0.000 0.000 0.000 0.000 0.000 0.000 29699.092 0.000 0.000 0.000
September 0.128802E+12 86015.242 08-SEP-17:30 8572.775 26456.413 8108.927 0.000 14089.625 0.000 0.000 0.000 0.000 0.000 0.000 28787.502 0.000 0.000 0.000
October 0.122139E+12 79525.283 10-OCT-17:45 8572.775 26456.413 8108.927 0.000 8595.651 2508.330 0.000 0.000 0.000 0.000 0.000 25283.187 0.000 0.000 0.000
November 0.117512E+12 76170.468 07-NOV-18:15 8572.775 26456.413 8108.927 0.000 4389.787 2508.330 0.000 0.000 0.000 0.000 0.000 26134.236 0.000 0.000 0.000
December 0.121719E+12 74824.316 13-DEC-18:15 8572.775 26456.413 8108.927 0.000 284.250 2508.330 0.000 0.000 0.000 0.000 0.000 28893.621 0.000 0.000 0.000
                                     
Annual Sum or Average 0.150960E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.111660E+12 74824.316   8572.775 26456.413 8108.927 0.000 284.250 0.000 0.000 0.000 0.000 0.000 0.000 24593.821 0.000 0.000 0.000
Maximum of Months 0.140370E+12 92107.982   8572.775 26456.413 8108.927 0.000 19196.011 2508.330 0.000 0.000 0.000 0.000 0.000 29773.856 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:29

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.321688E+11 62554.444 05-JAN-02:00 62554.444 0.000 0.000 0.000 0.000 0.000 62554.444
February 0.404905E+11 75780.910 12-FEB-04:00 75780.910 0.000 0.000 0.000 0.000 0.000 75780.910
March 0.263945E+11 84910.049 19-MAR-06:00 84910.049 0.000 0.000 0.000 0.000 0.000 84910.049
April 0.186656E+11 48301.500 17-APR-02:00 48301.500 0.000 0.000 0.000 0.000 0.000 48301.500
May 0.116688E+10 14316.451 03-MAY-02:00 14316.451 0.000 0.000 0.000 0.000 0.000 14316.451
June 0.000 0.000 01-JUN-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.268916E+09 8917.349 22-SEP-04:00 8917.349 0.000 0.000 0.000 0.000 0.000 8917.349
October 0.158302E+11 52720.629 31-OCT-23:00 52720.629 0.000 0.000 0.000 0.000 0.000 52720.629
November 0.252277E+11 66974.089 30-NOV-05:00 66974.089 0.000 0.000 0.000 0.000 0.000 66974.089
December 0.587030E+11 96671.034 22-DEC-03:00 96671.034 0.000 0.000 0.000 0.000 0.000 96671.034
                     
Annual Sum or Average 0.218916E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.587030E+11 96671.034   96671.034 0.000 0.000 0.000 0.000 0.000 96671.034