Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Great Falls Intl Arpt MT USA TMY3 WMO#=727750

Simulation Timestamp: 2018-10-19 09:20:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1920.93 612.81 680.22
Net Site Energy 1920.93 612.81 680.22
Total Source Energy 5171.88 1649.93 1831.42
Net Source Energy 5171.88 1649.93 1831.42


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 437.68 0.00 0.00 0.00 0.00
Cooling 80.47 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 39.36 0.00 0.00 0.00 0.00 0.00
Interior Equipment 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 248.66 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 438.33 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1483.24 437.68 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 437.68 0.00 0.00 0.00 0.00
Cooling General 80.47 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 138.97 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 26.03 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 39.36 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 511.42 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 248.66 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 438.33 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 72.37 0.00 0.00 0.00 0.00 0.00
HVAC 271.77 154.99 0.00 0.00 0.00 0.66
Other 181.10 0.00 0.00 0.00 0.00 0.00
Total 525.23 154.99 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.20 0.00 0.00 0.00 0.00 0.00
HVAC 244.83 139.63 0.00 0.00 0.00 0.60
Other 163.15 0.00 0.00 0.00 0.00 0.00
Total 473.18 139.63 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1483.24 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1483.24 100.00
     
Total On-Site and Utility Electric Sources 1483.24 100.00
Total Electricity End Uses 1483.24 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 41.25
Time Setpoint Not Met During Occupied Cooling 0.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 2873.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
RunPeriod Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Weather File Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Latitude [deg] 47.47
Longitude [deg] -111.4
Elevation [m] 1117.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 14.4236 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 8.5250   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 8.5250   208.0991
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 8.5250   0.0000
Total 3134.61     9553.84   1542.04 306.92 14.1058 39.93 11.1646
Conditioned Total 2823.98     8607.06   1501.17 300.26 14.7196 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 8.5250   52.0248
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 07-AUG-17:30 10-JAN-23:15 - - - 01-JAN-07:15
Heating 0.00 127311.21 0.00 0.00 0.00 0.00
Cooling 19649.16 0.00 0.00 0.00 0.00 0.00
Interior Lighting 8572.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 7884.96 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 28486.34 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 91049.64 127311.21 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 127311.21 0.00 0.00 0.00 0.00
Cooling General 19649.16 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7168.38 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1404.40 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26456.41 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 7884.96 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 28486.34 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 474.45 0.00 0.00 0.00
Cooling 254.86 0.00 0.00 0.00 0.00
Interior Lighting 522.56 0.00 0.00 0.00 0.00
Exterior Lighting 124.66 0.00 0.00 0.00 0.00
Interior Equipment 1619.66 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 787.51 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1388.18 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4697.43 474.45 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 168.01 0.00 0.00 0.00
Cooling 90.25 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.14 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 278.86 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 491.57 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1663.41 168.01 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 168.01 0.00 0.00 0.00
Cooling 90.25 0.00 0.00 0.00 0.00
Interior Lighting 185.05 0.00 0.00 0.00 0.00
Exterior Lighting 44.14 0.00 0.00 0.00 0.00
Interior Equipment 573.54 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 278.86 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 491.57 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1663.41 168.01 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB -27.60 0.00 -27.60 Wetbulb [C] 2.70 230.00
GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 33.40 16.00 16.30 Wetbulb [C] 4.90 240.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.48_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.48_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GNW G NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_HARDWIRED_GNE G NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSW M SW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNW M NW APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MSE M SE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MNE M NE APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 11.5174 176.50 2032.80 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSW T SW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNW T NW APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TSE T SE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TNE T NE APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 11.5174 88.25 1016.40 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
LIGHTING_HARDWIRED_GC G CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_MC M CORRIDOR 8.5250 155.32 1324.09 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_HARDWIRED_TC T CORRIDOR 8.5250 77.66 662.05 GeneralLights LTG_COR_SCH 137.36 168.00 137.36 0.0000 N 17.07
LIGHTING_PLUGIN_GSW G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GNW G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_OFFICE OFFICE 11.9479 88.25 1054.40 GeneralLights-plugin LTG_OFF_SCH 56.36 168.00 55.36 0.0000 Y 10.96
LIGHTING_PLUGIN_GNE G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSW M SW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNW M NW APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MSE M SE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MNE M NE APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 2.9063 176.50 512.95 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSW T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNW T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TSE T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TNE T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.4206 5958.59 44216.13               128.63


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2508.33 AstronomicalClock -   83.60 83.60 39.36
Exterior Lighting Total 2508.33           39.36



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3315.72 2648.12 667.60 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   3040.94 2428.66 612.28 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   8036.78 6418.62 1618.16 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   2113.03 1687.59 425.45 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1756.90 1403.15 353.74 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1734.99 1385.66 349.33 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2119.77 1692.97 426.80 0.80 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2176.53 1738.29 438.23 0.80 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   9206.45 7352.78 1853.67 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   8363.39 6679.47 1683.93 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   8199.04 6548.20 1650.83 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   6259.16 4998.91 1260.25 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5117.06 4086.77 1030.29 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5079.57 4056.83 1022.75 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6229.75 4975.42 1254.33 0.80 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6253.72 4994.56 1259.15 0.80 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   6080.76 4856.43 1224.33 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   5453.53 4355.49 1098.04 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5656.54 4517.63 1138.92 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   4244.24 3389.69 854.56 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3387.86 2705.73 682.13 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3350.06 2675.54 674.52 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4668.40 3728.44 939.96 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4683.89 3740.81 943.08 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3158.7 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2897.0 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 7656.3 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2013.0 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1673.7 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1652.9 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2019.4 3.13 10.67 11.09 10.38
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2073.5 3.13 10.67 11.09 10.38
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 8770.6 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 7967.5 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7810.9 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 5962.8 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4874.8 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4839.1 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5934.8 3.13 10.67 11.09 10.38
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5957.7 3.13 10.67 11.09 10.38
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5792.9 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 5195.3 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5388.7 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4043.3 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3227.5 3.13 10.67 11.09 10.38
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3191.5 3.13 10.67 11.09 10.38
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4447.4 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4462.1 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   3715.45 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   3650.10 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   6578.63 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   3638.22 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   2785.46 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   2785.18 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   2805.01 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   2940.84 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   7233.34 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   7190.91 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   7202.18 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   7159.71 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   5079.33 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   5078.58 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   5124.95 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   5124.21 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   5405.92 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   5385.11 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   5389.39 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   5368.56 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   4288.08 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   4287.66 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   4307.84 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   4307.43 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 224.36 1120.11 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 205.77 1120.11 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.49 543.81 1120.11 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 142.98 1120.11 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.11 118.88 1120.11 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 117.40 1120.11 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 143.44 1120.11 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 147.28 1120.11 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.56 622.96 1120.11 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.51 565.92 1120.11 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.50 554.79 1120.11 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.38 423.53 1120.11 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 346.25 1120.11 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 343.71 1120.11 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.38 421.54 1120.11 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.38 423.16 1120.11 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.37 411.46 1120.11 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 369.02 1120.11 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 382.75 1120.11 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 287.19 1120.11 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 229.24 1120.11 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 226.68 1120.11 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 315.89 1120.11 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 316.94 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.89



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1864.25 2237.10 0.167 0.200 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 29.56 0.00627
G NW APARTMENT 1709.75 2051.70 0.153 0.184 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 28.36 0.00627
OFFICE 4421.10 5305.32 0.405 0.486 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:00:00 24.60 0.00627
G NE APARTMENT 1188.04 1425.65 0.106 0.128 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 27.16 0.00627
G N1 APARTMENT 987.80 1185.35 0.088 0.106 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 26.72 0.00627
G N2 APARTMENT 975.48 1170.58 0.087 0.105 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 26.72 0.00627
G S1 APARTMENT 1191.83 1430.20 0.107 0.128 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 33.40 0.00627
G S2 APARTMENT 1223.74 1468.49 0.110 0.131 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 33.40 0.00627
M SW APARTMENT 5176.31 6211.57 0.463 0.556 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 29.56 0.00627
M NW APARTMENT 4702.29 5642.75 0.421 0.505 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.76 0.00627
M SE APARTMENT 4609.94 5531.93 0.413 0.495 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 33.20 0.00627
M NE APARTMENT 3519.23 4223.08 0.315 0.378 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 29.12 0.00627
M N1 APARTMENT 2877.02 3452.42 0.258 0.309 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 26.72 0.00627
M N2 APARTMENT 2855.94 3427.13 0.256 0.307 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:15:00 26.72 0.00627
M S1 APARTMENT 3502.67 4203.20 0.314 0.376 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 33.40 0.00627
M S2 APARTMENT 3516.14 4219.37 0.315 0.378 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 33.40 0.00627
T SW APARTMENT 3418.97 4102.76 0.306 0.367 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 32.12 0.00627
T NW APARTMENT 3066.25 3679.51 0.275 0.329 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 29.56 0.00627
T SE APARTMENT 3180.45 3816.54 0.285 0.342 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 33.40 0.00627
T NE APARTMENT 2386.37 2863.65 0.214 0.256 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 33.40 0.00627
T N1 APARTMENT 1904.81 2285.78 0.171 0.205 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 29.56 0.00627
T N2 APARTMENT 1883.56 2260.27 0.169 0.202 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 29.56 0.00627
T S1 APARTMENT 2624.82 3149.78 0.235 0.282 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 33.40 0.00627
T S2 APARTMENT 2633.52 3160.23 0.236 0.283 GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 33.40 0.00627


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1955.24 2346.29 0.064 0.077 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G NW APARTMENT 1941.69 2330.03 0.064 0.077 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
OFFICE 3924.79 4709.75 0.125 0.150 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G NE APARTMENT 1931.65 2317.98 0.064 0.076 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G N1 APARTMENT 1210.50 1452.60 0.040 0.048 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G N2 APARTMENT 1210.27 1452.32 0.040 0.048 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G S1 APARTMENT 1227.03 1472.44 0.040 0.048 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
G S2 APARTMENT 1341.90 1610.28 0.044 0.053 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -27.60 0.00034
M SW APARTMENT 3826.91 4592.29 0.126 0.151 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M NW APARTMENT 3791.03 4549.23 0.125 0.150 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M SE APARTMENT 3800.55 4560.67 0.125 0.150 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M NE APARTMENT 3764.64 4517.57 0.124 0.149 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M N1 APARTMENT 2005.32 2406.39 0.066 0.079 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M N2 APARTMENT 2004.70 2405.64 0.066 0.079 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M S1 APARTMENT 2043.90 2452.69 0.067 0.081 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
M S2 APARTMENT 2043.28 2451.94 0.067 0.081 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T SW APARTMENT 3426.55 4111.86 0.113 0.135 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T NW APARTMENT 3408.96 4090.75 0.112 0.135 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T SE APARTMENT 3412.57 4095.09 0.112 0.135 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T NE APARTMENT 3394.96 4073.95 0.112 0.134 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T N1 APARTMENT 2481.22 2977.47 0.082 0.098 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T N2 APARTMENT 2480.87 2977.04 0.082 0.098 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T S1 APARTMENT 2497.94 2997.52 0.082 0.099 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034
T S2 APARTMENT 2497.58 2997.10 0.082 0.099 GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -27.60 0.00034


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.20 0.20 0.08 0.08
SPLIT GNW 0.18 0.18 0.08 0.08
SPLIT OFFICE 0.49 0.49 0.15 0.15
SPLIT GNE 0.13 0.13 0.08 0.08
SPLIT GN1 0.11 0.11 0.05 0.05
SPLIT GN2 0.10 0.10 0.05 0.05
SPLIT GS1 0.13 0.13 0.05 0.05
SPLIT GS2 0.13 0.13 0.05 0.05
SPLIT MSW 0.56 0.56 0.15 0.15
SPLIT MNW 0.51 0.51 0.15 0.15
SPLIT MSE 0.50 0.50 0.15 0.15
SPLIT MNE 0.38 0.38 0.15 0.15
SPLIT MN1 0.31 0.31 0.08 0.08
SPLIT MN2 0.31 0.31 0.08 0.08
SPLIT MS1 0.38 0.38 0.08 0.08
SPLIT MS2 0.38 0.38 0.08 0.08
SPLIT TSW 0.37 0.37 0.14 0.14
SPLIT TNW 0.33 0.33 0.13 0.13
SPLIT TSE 0.34 0.34 0.13 0.13
SPLIT TNE 0.26 0.26 0.13 0.13
SPLIT TN1 0.20 0.20 0.10 0.10
SPLIT TN2 0.20 0.20 0.10 0.10
SPLIT TS1 0.28 0.28 0.10 0.10
SPLIT TS2 0.28 0.28 0.10 0.10



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2298.00 6553.50 1540.50
G NW APARTMENT 2622.25 6818.75 2180.50
OFFICE 327.50 1711.75 268.25
G NE APARTMENT 2654.50 6839.50 2171.00
G N1 APARTMENT 1850.00 6981.25 1594.25
G N2 APARTMENT 1850.50 6981.75 1593.00
G S1 APARTMENT 1486.75 6595.25 983.75
G S2 APARTMENT 1554.00 6622.25 1076.75
M SW APARTMENT 2233.50 5018.50 671.50
M NW APARTMENT 2304.00 5810.50 1141.25
M SE APARTMENT 2267.75 5020.50 662.75
M NE APARTMENT 2348.75 5861.75 1119.75
M N1 APARTMENT 1522.75 5786.25 676.00
M N2 APARTMENT 1526.50 5794.25 676.00
M S1 APARTMENT 1677.75 4730.50 348.25
M S2 APARTMENT 1680.50 4732.00 348.25
T SW APARTMENT 3558.50 5808.00 2054.75
T NW APARTMENT 3980.75 6327.25 2735.75
T SE APARTMENT 3587.75 5769.00 2038.50
T NE APARTMENT 4002.00 6325.75 2702.50
T N1 APARTMENT 3424.50 6395.75 2342.25
T N2 APARTMENT 3429.00 6397.75 2344.00
T S1 APARTMENT 2981.00 5739.00 1598.00
T S2 APARTMENT 2983.50 5733.00 1598.75
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 4852.25 7087.75 2873.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 4.50 0.00 4.50 0.00
G NW APARTMENT 4.75 0.00 4.75 0.00
OFFICE 10.25 0.00 0.25 0.00
G NE APARTMENT 2.25 0.00 2.25 0.00
G N1 APARTMENT 3.25 0.00 3.25 0.00
G N2 APARTMENT 2.00 0.00 2.00 0.00
G S1 APARTMENT 2.50 0.00 2.50 0.00
G S2 APARTMENT 1.25 0.00 1.25 0.00
M SW APARTMENT 1.50 0.00 1.50 0.00
M NW APARTMENT 1.75 0.00 1.75 0.00
M SE APARTMENT 1.25 0.00 1.25 0.00
M NE APARTMENT 1.75 0.00 1.75 0.00
M N1 APARTMENT 2.50 0.00 2.50 0.00
M N2 APARTMENT 1.25 0.00 1.25 0.00
M S1 APARTMENT 0.50 0.00 0.50 0.00
M S2 APARTMENT 0.50 0.00 0.50 0.00
T SW APARTMENT 0.25 0.00 0.25 0.00
T NW APARTMENT 0.00 0.50 0.00 0.50
T SE APARTMENT 0.50 0.00 0.50 0.00
T NE APARTMENT 1.00 0.00 1.00 0.00
T N1 APARTMENT 3.50 0.00 3.50 0.00
T N2 APARTMENT 5.25 0.00 5.25 0.00
T S1 APARTMENT 1.75 0.00 1.75 0.00
T S2 APARTMENT 2.00 0.00 2.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 51.25 0.50 41.25 0.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.365 0.133 0.000 0.066
G NW APARTMENT 1.71 2.50 268.97 0.352 0.132 0.000 0.065
OFFICE 0.94 1.00 268.97 0.518 0.151 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.352 0.132 0.000 0.065
G N1 APARTMENT 1.71 2.50 268.97 0.352 0.080 0.000 0.065
G N2 APARTMENT 1.71 2.50 268.97 0.352 0.080 0.000 0.065
G S1 APARTMENT 1.71 2.50 268.97 0.352 0.080 0.000 0.066
G S2 APARTMENT 1.71 2.50 268.97 0.352 0.080 0.000 0.066
M SW APARTMENT 1.71 2.50 268.97 0.353 0.191 0.000 0.083
M NW APARTMENT 1.71 2.50 268.97 0.352 0.191 0.000 0.083
M SE APARTMENT 1.71 2.50 268.97 0.353 0.191 0.000 0.083
M NE APARTMENT 1.71 2.50 268.97 0.352 0.191 0.000 0.083
M N1 APARTMENT 1.71 2.50 268.97 0.352 0.115 0.000 0.083
M N2 APARTMENT 1.71 2.50 268.97 0.352 0.115 0.000 0.083
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.115 0.000 0.083
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.115 0.000 0.083
T SW APARTMENT 1.71 2.50 268.97 0.352 0.252 0.000 0.101
T NW APARTMENT 1.71 2.50 268.97 0.352 0.252 0.000 0.101
T SE APARTMENT 1.71 2.50 268.97 0.352 0.252 0.000 0.101
T NE APARTMENT 1.71 2.50 268.97 0.352 0.252 0.000 0.101
T N1 APARTMENT 1.71 2.50 268.97 0.352 0.152 0.000 0.101
T N2 APARTMENT 1.71 2.50 268.97 0.352 0.152 0.000 0.101
T S1 APARTMENT 1.71 2.50 268.97 0.352 0.152 0.000 0.101
T S2 APARTMENT 1.71 2.50 268.97 0.352 0.152 0.000 0.101
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.353 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.500 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1425
Defaulted Fields 439
Fields with Defaults 3748
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1483.24 21255.26 12-JAN-03:30 91049.64 07-AUG-17:30
Electricity:Building 676.42 10861.97 01-JAN-03:15 35029.19 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity 165.00 2991.26 01-JAN-00:15 9689.08 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 138.97 2711.50 01-JAN-00:15 8059.76 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.45 508.27 01-JAN-00:15 2167.25 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.91 379.58 01-JAN-00:15 1622.34 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 29.25 476.16 01-JAN-03:15 1566.15 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 4.83 28.81 01-JAN-00:15 460.92 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.08 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 142.36 1349.33 01-JAN-00:15 8621.71 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 34.14 1082.58 01-JAN-00:15 1082.58 01-JAN-00:15
Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 17.07 541.29 01-JAN-00:15 541.29 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 26.03 279.76 01-JAN-00:15 1629.32 01-JAN-19:15
InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 511.42 7870.70 01-JAN-03:15 26522.71 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.53 128.69 01-JAN-00:15 544.92 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 125.29 808.04 01-JAN-00:15 8080.42 01-JAN-07:15
Electricity:Plant 438.33 0.00 01-JAN-00:15 32883.59 23-FEB-07:15
WaterSystems:Electricity 438.33 0.00 01-JAN-00:15 32883.59 23-FEB-07:15
Water Heater:WaterSystems:Electricity 438.33 0.00 01-JAN-00:15 32883.59 23-FEB-07:15
Fans:Electricity 248.66 7884.96 03-JAN-06:15 7884.96 04-JAN-08:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
ElectricityPurchased:Plant 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
Cogeneration:ElectricityPurchased 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
ElectricityNet:Plant 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
Cogeneration:ElectricityNet 1483.24 21255.26 01-JAN-03:15 91049.64 07-AUG-17:30
ExteriorLights:Electricity 39.36 0.00 01-JAN-08:30 2508.33 01-JAN-00:15
General:ExteriorLights:Electricity 39.36 0.00 01-JAN-08:30 2508.33 01-JAN-00:15
Electricity:HVAC 329.13 7884.96 03-JAN-06:15 32139.29 17-JUL-16:15
General:Fans:Electricity 248.66 7884.96 03-JAN-06:15 7884.96 04-JAN-08:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 80.47 0.00 01-JAN-00:15 24254.33 17-JUL-16:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 437.68 0.00 20-FEB-15:45 127311.21 10-JAN-23:15
Gas:HVAC 437.68 0.00 20-FEB-15:45 127311.21 10-JAN-23:15
Heating:Gas 437.68 0.00 20-FEB-15:45 127311.21 10-JAN-23:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1198.48 1541.09 01-APR-12:30 163075.42 10-JAN-23:15
EnergyTransfer:Building 534.84 1520.94 01-APR-12:30 67185.01 17-JUL-16:15
EnergyTransfer:Zone:G SW APARTMENT 13.20 0.09 17-NOV-09:00 2164.05 02-SEP-15:15
Heating:EnergyTransfer 188.68 0.00 20-FEB-18:30 61435.04 11-JAN-08:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 6.27 0.00 01-JAN-10:30 2026.20 11-JAN-08:15
Cooling:EnergyTransfer 346.16 0.00 05-JAN-08:00 67185.01 17-JUL-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 6.93 0.00 01-JAN-00:15 2164.05 02-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 13.40 0.02 30-MAY-04:00 2034.72 11-JAN-08:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 8.75 0.00 14-JAN-15:15 2034.72 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.65 0.00 01-JAN-00:15 1924.24 17-JUL-17:45
EnergyTransfer:Zone:OFFICE 20.28 0.01 04-NOV-00:30 4177.56 31-DEC-07:30
Heating:EnergyTransfer:Zone:OFFICE 0.75 0.00 01-JAN-00:15 4177.56 31-DEC-07:30
Cooling:EnergyTransfer:Zone:OFFICE 19.53 0.00 02-JAN-07:45 3562.37 10-AUG-13:00
EnergyTransfer:Zone:G NE APARTMENT 13.57 0.01 30-MAY-11:30 2027.78 11-JAN-08:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 8.55 0.00 12-FEB-16:15 2027.78 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G NE APARTMENT 5.02 0.00 01-JAN-00:15 1387.37 17-JUL-18:30
EnergyTransfer:Zone:G N1 APARTMENT 8.83 0.00 28-MAY-09:15 1249.37 11-JAN-08:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 4.27 0.00 01-JAN-17:15 1249.37 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 4.56 0.00 01-JAN-00:15 1106.22 17-JUL-18:30
EnergyTransfer:Zone:G N2 APARTMENT 8.83 0.14 18-AUG-12:00 1249.43 11-JAN-08:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 4.26 0.00 01-JAN-17:15 1249.43 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 4.57 0.00 01-JAN-00:15 1094.51 17-JUL-18:30
EnergyTransfer:Zone:G S1 APARTMENT 9.70 0.01 23-OCT-11:45 1522.58 02-SEP-14:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 2.54 0.00 01-JAN-09:15 1242.43 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 7.16 0.00 01-JAN-00:15 1522.58 02-SEP-14:15
EnergyTransfer:Zone:G S2 APARTMENT 9.94 0.07 17-NOV-15:15 1505.24 02-SEP-14:15
Heating:EnergyTransfer:Zone:G S2 APARTMENT 2.98 0.00 01-JAN-09:30 1344.02 11-JAN-08:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 6.96 0.00 01-JAN-00:15 1505.24 02-SEP-14:15
EnergyTransfer:Zone:M SW APARTMENT 36.91 0.03 16-NOV-22:30 5909.30 02-SEP-15:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 7.20 0.00 01-JAN-00:15 4006.80 10-JAN-23:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 29.71 0.00 03-JAN-05:45 5909.30 02-SEP-15:15
EnergyTransfer:Zone:M NW APARTMENT 32.12 0.03 07-NOV-20:45 5196.11 14-JUL-18:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 12.46 0.00 01-JAN-14:30 4131.69 10-JAN-23:15
Cooling:EnergyTransfer:Zone:M NW APARTMENT 19.66 0.00 01-JAN-00:15 5196.11 14-JUL-18:30
EnergyTransfer:Zone:M SE APARTMENT 37.85 0.00 12-APR-11:30 5403.79 02-SEP-14:15
Heating:EnergyTransfer:Zone:M SE APARTMENT 7.08 0.00 01-JAN-00:15 3984.46 10-JAN-23:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 30.77 0.00 03-JAN-05:30 5403.79 02-SEP-14:15
EnergyTransfer:Zone:M NE APARTMENT 33.02 0.15 28-MAR-03:15 4109.01 10-JAN-23:15
Heating:EnergyTransfer:Zone:M NE APARTMENT 12.18 0.00 01-JAN-16:15 4109.01 10-JAN-23:15
Cooling:EnergyTransfer:Zone:M NE APARTMENT 20.84 0.00 01-JAN-00:15 3987.85 17-JUL-18:30
EnergyTransfer:Zone:M N1 APARTMENT 24.51 0.03 24-APR-13:45 3163.63 17-JUL-18:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 3.94 0.00 01-JAN-00:15 2135.79 11-JAN-01:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 20.58 0.00 01-JAN-01:00 3163.63 17-JUL-18:30
EnergyTransfer:Zone:M N2 APARTMENT 24.52 0.01 15-OCT-10:00 3144.58 17-JUL-18:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 3.93 0.00 01-JAN-00:15 2135.81 11-JAN-01:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 20.59 0.00 01-JAN-01:00 3144.58 17-JUL-18:30
EnergyTransfer:Zone:M S1 APARTMENT 34.59 0.26 07-APR-08:45 4398.59 02-SEP-14:15
Heating:EnergyTransfer:Zone:M S1 APARTMENT 1.71 0.00 01-JAN-00:15 2027.03 11-JAN-01:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 32.89 0.00 05-JAN-04:00 4398.59 02-SEP-14:15
EnergyTransfer:Zone:M S2 APARTMENT 34.60 0.48 07-APR-08:45 4408.02 02-SEP-14:15
Heating:EnergyTransfer:Zone:M S2 APARTMENT 1.71 0.00 01-JAN-00:15 2027.07 11-JAN-01:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 32.90 0.00 05-JAN-04:00 4408.02 02-SEP-14:15
EnergyTransfer:Zone:T SW APARTMENT 26.03 0.00 16-AUG-24:00 3913.68 17-JUL-16:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 13.98 0.00 01-JAN-11:00 3762.98 10-JAN-23:15
Cooling:EnergyTransfer:Zone:T SW APARTMENT 12.06 0.00 01-JAN-00:15 3913.68 17-JUL-16:15
EnergyTransfer:Zone:T NW APARTMENT 26.16 0.00 15-MAY-11:30 3791.72 10-JAN-23:15
Heating:EnergyTransfer:Zone:T NW APARTMENT 17.80 0.00 12-FEB-16:00 3791.72 10-JAN-23:15
Cooling:EnergyTransfer:Zone:T NW APARTMENT 8.36 0.00 01-JAN-00:15 3543.63 17-JUL-17:15
EnergyTransfer:Zone:T SE APARTMENT 25.89 0.01 04-JUL-03:45 3745.68 10-JAN-23:15
Heating:EnergyTransfer:Zone:T SE APARTMENT 13.69 0.00 01-JAN-10:15 3745.68 10-JAN-23:15
Cooling:EnergyTransfer:Zone:T SE APARTMENT 12.20 0.00 01-JAN-00:15 3538.13 02-SEP-14:15
EnergyTransfer:Zone:T NE APARTMENT 26.03 0.02 09-SEP-03:30 3774.36 10-JAN-23:15
Heating:EnergyTransfer:Zone:T NE APARTMENT 17.43 0.00 12-FEB-15:30 3774.36 10-JAN-23:15
Cooling:EnergyTransfer:Zone:T NE APARTMENT 8.60 0.00 01-JAN-00:15 2824.46 17-JUL-16:15
EnergyTransfer:Zone:T N1 APARTMENT 18.34 0.05 10-SEP-06:45 2681.46 11-JAN-01:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 10.92 0.00 01-JAN-18:15 2681.46 11-JAN-01:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 7.42 0.00 01-JAN-00:15 2317.41 17-JUL-16:15
EnergyTransfer:Zone:T N2 APARTMENT 18.36 0.01 07-JUN-14:00 2681.17 11-JAN-01:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 10.92 0.00 01-JAN-18:15 2681.17 11-JAN-01:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 7.44 0.00 01-JAN-00:15 2305.61 17-JUL-16:15
EnergyTransfer:Zone:T S1 APARTMENT 19.06 0.05 18-AUG-00:30 3006.25 02-SEP-14:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 7.69 0.00 01-JAN-10:00 2661.19 11-JAN-00:45
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 11.37 0.00 01-JAN-00:15 3006.25 02-SEP-14:15
EnergyTransfer:Zone:T S2 APARTMENT 19.09 0.02 03-MAY-01:15 3011.86 02-SEP-14:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 7.69 0.00 01-JAN-10:00 2660.90 11-JAN-00:45
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 11.40 0.00 01-JAN-00:15 3011.86 02-SEP-14:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 663.64 0.00 11-MAR-17:00 101848.97 10-JAN-23:15
HeatingCoils:EnergyTransfer 350.15 0.00 20-FEB-15:45 101848.97 10-JAN-23:15
CoolingCoils:EnergyTransfer 313.49 0.00 01-JAN-00:15 86380.42 17-JUL-16:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 6.271 -6.928 0.000 0.000 3.874 2.413 12.213 14.039 0.000 0.090 0.000 0.000 -9.448 0.000 -5.779 -16.746
G NW APARTMENT 8.754 -4.650 0.000 0.000 3.900 2.413 12.213 6.258 0.000 0.090 0.000 0.000 -9.897 0.000 -5.667 -13.414
OFFICE 0.749 -19.532 0.000 0.000 0.531 21.914 7.534 14.286 0.000 0.082 0.000 0.000 -8.840 0.000 -4.872 -11.852
G NE APARTMENT 8.548 -5.022 0.000 0.000 3.911 2.413 12.213 6.380 0.000 0.090 0.000 0.000 -9.600 0.000 -5.654 -13.280
G N1 APARTMENT 4.267 -4.558 0.000 0.000 3.907 2.413 12.213 2.079 0.000 0.062 0.000 0.000 -6.152 0.000 -3.655 -10.575
G N2 APARTMENT 4.263 -4.565 0.000 0.000 3.907 2.413 12.213 2.078 0.000 0.062 0.000 0.000 -6.150 0.000 -3.655 -10.565
G S1 APARTMENT 2.541 -7.162 0.000 0.000 3.872 2.413 12.213 9.967 0.000 0.062 0.000 0.000 -5.739 0.000 -3.771 -14.396
G S2 APARTMENT 2.975 -6.963 0.000 0.000 3.872 2.413 12.213 9.969 0.000 0.062 0.000 0.000 -5.728 0.000 -3.771 -15.040
M SW APARTMENT 7.201 -29.708 0.000 0.000 3.761 2.413 12.213 13.580 0.000 0.127 9.024 0.000 -10.160 0.000 -8.451 -0.001
M NW APARTMENT 12.457 -19.665 0.000 0.000 3.820 2.413 12.213 5.938 0.000 0.126 1.461 0.000 -10.504 0.000 -8.259 -0.000
M SE APARTMENT 7.081 -30.766 0.000 0.000 3.768 2.413 12.213 13.761 0.000 0.127 9.753 0.000 -9.904 0.000 -8.445 -0.001
M NE APARTMENT 12.179 -20.838 0.000 0.000 3.833 2.413 12.213 6.056 0.000 0.126 2.426 0.000 -10.170 0.000 -8.239 -0.000
M N1 APARTMENT 3.935 -20.580 0.000 0.000 3.809 2.413 12.213 1.888 0.000 0.085 8.189 0.000 -6.595 0.000 -5.357 -0.000
M N2 APARTMENT 3.930 -20.588 0.000 0.000 3.810 2.413 12.213 1.887 0.000 0.085 8.198 0.000 -6.593 0.000 -5.356 -0.000
M S1 APARTMENT 1.708 -32.886 0.000 0.000 3.726 2.413 12.213 9.660 0.000 0.086 14.834 0.000 -6.224 0.000 -5.530 -0.000
M S2 APARTMENT 1.706 -32.899 0.000 0.000 3.726 2.413 12.213 9.659 0.000 0.086 14.849 0.000 -6.223 0.000 -5.530 -0.000
T SW APARTMENT 13.977 -12.056 0.000 0.000 3.839 2.413 12.213 13.518 0.000 0.169 0.000 0.000 -9.627 0.000 -10.823 -13.624
T NW APARTMENT 17.798 -8.359 0.000 0.000 3.872 2.413 12.213 5.906 0.000 0.169 0.000 0.000 -10.024 0.000 -10.633 -13.354
T SE APARTMENT 13.690 -12.199 0.000 0.000 3.843 2.413 12.213 13.715 0.000 0.169 0.000 0.000 -9.400 0.000 -10.838 -13.607
T NE APARTMENT 17.431 -8.596 0.000 0.000 3.884 2.413 12.213 6.046 0.000 0.169 0.000 0.000 -9.720 0.000 -10.628 -13.212
T N1 APARTMENT 10.919 -7.423 0.000 0.000 3.874 2.413 12.213 1.903 0.000 0.115 0.000 0.000 -6.242 0.000 -6.807 -10.964
T N2 APARTMENT 10.923 -7.441 0.000 0.000 3.875 2.413 12.213 1.901 0.000 0.115 0.000 0.000 -6.240 0.000 -6.808 -10.951
T S1 APARTMENT 7.688 -11.372 0.000 0.000 3.823 2.413 12.213 9.641 0.000 0.116 0.000 0.000 -5.883 0.000 -6.998 -11.641
T S2 APARTMENT 7.693 -11.399 0.000 0.000 3.823 2.413 12.213 9.639 0.000 0.116 0.000 0.000 -5.881 0.000 -7.000 -11.616
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.079 0.000 0.009 0.000 0.000 -1.184 0.000 -1.737 -14.237
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 6.264 0.292 0.000 0.296 3.543 0.000 -3.196 0.000 -24.270 -0.001
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 17.070 0.000 0.079 0.000 0.008 0.000 0.000 -1.302 0.000 -1.439 -14.416
Total Facility 188.684 -346.157 0.000 0.000 88.857 128.627 294.692 190.205 0.000 2.900 72.277 0.000 -196.625 0.000 -189.969 -233.495


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 02-SEP-15:15 0.00 -2163.92 0.00 0.00 48.90 100.83 470.90 2851.31 0.00 122.12 0.00 0.00 0.00 0.00 0.00 -1430.13
G NW APARTMENT 17-JUL-17:23 0.00 -1924.35 0.00 0.00 141.80 194.45 588.62 2088.60 0.00 60.76 0.00 0.00 0.00 0.00 0.00 -1149.89
OFFICE 10-AUG-13:00 0.00 -3561.64 0.00 0.00 67.31 1622.34 544.92 2236.76 0.00 133.22 0.00 0.00 0.00 0.00 0.00 -1042.91
G NE APARTMENT 17-JUL-18:30 0.00 -1387.37 0.00 0.00 141.81 230.46 547.42 827.85 0.00 35.66 0.00 0.00 0.00 0.00 0.00 -395.83
G N1 APARTMENT 17-JUL-18:30 0.00 -1106.22 0.00 0.00 141.81 230.46 547.42 621.27 0.00 21.51 0.00 0.00 0.00 0.00 0.00 -456.25
G N2 APARTMENT 17-JUL-18:30 0.00 -1094.51 0.00 0.00 141.81 230.46 547.42 621.43 0.00 21.51 0.00 0.00 0.00 0.00 0.00 -468.12
G S1 APARTMENT 02-SEP-14:15 0.00 -1522.39 0.00 0.00 40.75 50.41 400.26 1901.25 0.00 85.38 0.00 0.00 0.00 0.00 0.00 -955.66
G S2 APARTMENT 02-SEP-14:15 0.00 -1505.05 0.00 0.00 40.75 50.41 400.26 1901.55 0.00 85.39 0.00 0.00 0.00 0.00 0.00 -973.31
M SW APARTMENT 02-SEP-15:15 0.00 -5908.97 0.00 0.00 48.90 100.83 470.90 2829.54 0.00 175.14 2283.66 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 14-JUL-18:30 0.00 -5196.51 0.00 0.00 141.80 230.46 547.42 2175.05 0.00 83.63 2018.14 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 02-SEP-14:15 0.00 -5403.10 0.00 0.00 40.75 50.41 400.26 2161.35 0.00 203.03 2547.30 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 17-JUL-18:30 0.00 -3987.82 0.00 0.00 141.81 230.46 547.42 817.40 0.00 51.16 2199.57 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 17-JUL-18:30 0.00 -3163.61 0.00 0.00 141.81 230.46 547.42 613.57 0.00 30.86 1599.50 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 17-JUL-18:30 0.00 -3144.56 0.00 0.00 141.81 230.46 547.42 613.68 0.00 30.86 1580.33 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 02-SEP-14:15 0.00 -4398.06 0.00 0.00 40.75 50.41 400.26 1885.94 0.00 122.46 1898.23 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 02-SEP-14:15 0.00 -4407.49 0.00 0.00 40.75 50.41 400.26 1885.88 0.00 122.46 1907.72 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 17-JUL-16:04 0.00 -3914.76 0.00 0.00 84.76 144.04 588.62 2240.48 0.00 187.46 669.40 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 17-JUL-17:06 0.00 -3544.39 0.00 0.00 141.81 194.45 588.62 2057.24 0.00 130.01 432.25 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 02-SEP-14:15 0.00 -3537.69 0.00 0.00 40.75 50.41 400.26 2123.76 0.00 267.43 655.07 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 17-JUL-16:09 0.00 -2824.96 0.00 0.00 84.76 144.04 588.62 769.33 0.00 187.46 1050.76 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 17-JUL-16:13 0.00 -2318.52 0.00 0.00 84.76 144.04 588.62 467.79 0.00 113.07 920.24 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 17-JUL-16:11 0.00 -2306.65 0.00 0.00 84.76 144.04 588.62 467.93 0.00 113.07 908.22 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 02-SEP-14:15 0.00 -3005.91 0.00 0.00 40.75 50.41 400.26 1860.20 0.00 161.32 492.97 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 02-SEP-14:15 0.00 -3011.52 0.00 0.00 40.75 50.41 400.26 1860.10 0.00 161.32 498.68 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 17-JUL-16:04 0.00 -67206.73 0.00 0.00 1949.42 5316.35 14137.32 25202.78 0.00 5377.52 15223.34 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 11-JAN-08:15 2027.07 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -975.30 0.00 -577.02 -980.43
G NW APARTMENT 11-JAN-08:14 2035.48 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -953.37 0.00 -577.02 -1010.76
OFFICE 12-FEB-07:01 6197.32 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -364.63 0.00 -280.36 -6126.89
G NE APARTMENT 11-JAN-08:14 2028.54 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -939.92 0.00 -577.02 -1017.27
G N1 APARTMENT 11-JAN-08:14 1250.14 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -572.40 0.00 -348.05 -835.37
G N2 APARTMENT 11-JAN-08:14 1250.19 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -572.39 0.00 -348.05 -835.43
G S1 APARTMENT 29-JAN-18:38 1468.02 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -677.38 0.00 0.00 -1738.73
G S2 APARTMENT 11-JAN-08:15 1344.89 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -593.60 0.00 -348.05 -908.91
M SW APARTMENT 10-JAN-23:15 4006.79 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1405.80 0.00 -731.80 -2436.28
M NW APARTMENT 10-JAN-23:15 4131.68 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1373.62 0.00 -731.80 -2593.35
M SE APARTMENT 10-JAN-23:15 3984.46 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1386.05 0.00 -731.80 -2433.69
M NE APARTMENT 10-JAN-23:15 4109.00 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1353.94 0.00 -731.80 -2590.35
M N1 APARTMENT 08-MAY-06:01 2440.88 0.00 0.00 0.00 161.42 93.63 382.60 0.00 0.00 0.00 0.00 0.00 -329.42 0.00 -315.62 -2433.49
M N2 APARTMENT 16-DEC-18:14 2258.17 0.00 0.00 0.00 165.01 194.45 588.62 0.00 0.00 0.00 0.00 0.00 -534.72 0.00 -177.44 -2494.10
M S1 APARTMENT 11-JAN-01:00 2027.04 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -820.23 0.00 -379.76 -1296.01
M S2 APARTMENT 11-JAN-01:00 2027.08 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -820.22 0.00 -379.76 -1296.06
T SW APARTMENT 10-JAN-23:15 3762.97 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1379.76 0.00 -968.65 -1981.64
T NW APARTMENT 10-JAN-23:15 3791.70 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1345.14 0.00 -968.65 -2044.99
T SE APARTMENT 10-JAN-23:15 3745.67 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1358.73 0.00 -968.65 -1985.37
T NE APARTMENT 10-JAN-23:15 3774.35 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -1324.14 0.00 -968.65 -2048.64
T N1 APARTMENT 11-JAN-01:00 2681.47 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -772.13 0.00 -502.70 -1875.59
T N2 APARTMENT 11-JAN-01:00 2681.18 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -772.14 0.00 -502.70 -1875.29
T S1 APARTMENT 11-JAN-00:45 2661.20 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -806.24 0.00 -504.59 -1819.33
T S2 APARTMENT 11-JAN-00:45 2660.91 0.00 0.00 0.00 189.67 14.40 264.88 0.00 0.00 0.00 0.00 0.00 -806.24 0.00 -504.59 -1819.04
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-JAN-08:15 61453.23 0.00 0.00 0.00 1779.34 4240.08 9884.23 0.00 0.00 0.00 0.00 0.00 -18972.91 0.00 -18111.02 -40272.95



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Sec1.1A-General Information

Data
Weather File Great Falls Intl Arpt MT USA TMY3 WMO#=727750
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 41.25
Number of hours cooling loads not met 0.50
Number of hours not met 41.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 165.00 8572.78 0.00 0.00 0.00 0.00
Exterior Lighting 39.36 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 437.68 127311.21 0.00 0.00
Space Cooling 80.47 19649.16 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 248.66 7884.96 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 438.33 28486.34 0.00 0.00 0.00 0.00
Receptacle Equipment 511.42 26456.41 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1483.24   437.68   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 511.42 1483.24
Natural Gas 0.00 437.68
Additional 0.00 0.00
Total 511.42 1920.93


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 52.64
Space Heating 0.00
Space Cooling 25.67
Fans-Interior 79.33
Service Water Heating 139.83
Receptacle Equipment 163.15
Miscellaneous 12.56
Subtotal 473.18


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 139.63
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 139.63


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 8.59
Space Heating 22.79
Space Cooling 4.19
Fans-Interior 12.94
Service Water Heating 22.82
Receptacle Equipment 26.62
Miscellaneous 2.05



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.200303
G NW APARTMENT DIRECT AIR 0.183703
OFFICE DIRECT AIR 0.485502
G NE APARTMENT DIRECT AIR 0.127648
G N1 APARTMENT DIRECT AIR 0.106134
G N2 APARTMENT DIRECT AIR 0.104811
G S1 APARTMENT DIRECT AIR 0.128055
G S2 APARTMENT DIRECT AIR 0.131484
M SW APARTMENT DIRECT AIR 0.556162
M NW APARTMENT DIRECT AIR 0.505233
M SE APARTMENT DIRECT AIR 0.495304
M NE APARTMENT DIRECT AIR 0.378116
M N1 APARTMENT DIRECT AIR 0.309122
M N2 APARTMENT DIRECT AIR 0.306857
M S1 APARTMENT DIRECT AIR 0.376339
M S2 APARTMENT DIRECT AIR 0.377787
T SW APARTMENT DIRECT AIR 0.367339
T NW APARTMENT DIRECT AIR 0.329448
T SE APARTMENT DIRECT AIR 0.341712
T NE APARTMENT DIRECT AIR 0.256395
T N1 APARTMENT DIRECT AIR 0.204661
T N2 APARTMENT DIRECT AIR 0.202377
T S1 APARTMENT DIRECT AIR 0.282018
T S2 APARTMENT DIRECT AIR 0.282954


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.200303
SPLIT GNW MAIN BRANCH 0.183703
SPLIT OFFICE MAIN BRANCH 0.485502
SPLIT GNE MAIN BRANCH 0.127648
SPLIT GN1 MAIN BRANCH 0.106134
SPLIT GN2 MAIN BRANCH 0.104811
SPLIT GS1 MAIN BRANCH 0.128055
SPLIT GS2 MAIN BRANCH 0.131484
SPLIT MSW MAIN BRANCH 0.556162
SPLIT MNW MAIN BRANCH 0.505233
SPLIT MSE MAIN BRANCH 0.495304
SPLIT MNE MAIN BRANCH 0.378116
SPLIT MN1 MAIN BRANCH 0.309122
SPLIT MN2 MAIN BRANCH 0.306857
SPLIT MS1 MAIN BRANCH 0.376339
SPLIT MS2 MAIN BRANCH 0.377787
SPLIT TSW MAIN BRANCH 0.367339
SPLIT TNW MAIN BRANCH 0.329448
SPLIT TSE MAIN BRANCH 0.341712
SPLIT TNE MAIN BRANCH 0.256395
SPLIT TN1 MAIN BRANCH 0.204661
SPLIT TN2 MAIN BRANCH 0.202377
SPLIT TS1 MAIN BRANCH 0.282018
SPLIT TS2 MAIN BRANCH 0.282954


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.200303
SPLIT GNW 0.183703
SPLIT OFFICE 0.485502
SPLIT GNE 0.127648
SPLIT GN1 0.106134
SPLIT GN2 0.104811
SPLIT GS1 0.128055
SPLIT GS2 0.131484
SPLIT MSW 0.556162
SPLIT MNW 0.505233
SPLIT MSE 0.495304
SPLIT MNE 0.378116
SPLIT MN1 0.309122
SPLIT MN2 0.306857
SPLIT MS1 0.376339
SPLIT MS2 0.377787
SPLIT TSW 0.367339
SPLIT TNW 0.329448
SPLIT TSE 0.341712
SPLIT TNE 0.256395
SPLIT TN1 0.204661
SPLIT TN2 0.202377
SPLIT TS1 0.282018
SPLIT TS2 0.282954


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.200303 0.026898
SPLIT GNW OA CONTROLLER 0.183703 0.025953
SPLIT OFFICE OA CONTROLLER 0.485502 0.038104
SPLIT GNE OA CONTROLLER 0.127648 0.025953
SPLIT GN1 OA CONTROLLER 0.106134 0.025953
SPLIT GN2 OA CONTROLLER 0.104811 0.025953
SPLIT GS1 OA CONTROLLER 0.128055 0.025953
SPLIT GS2 OA CONTROLLER 0.131484 0.025953
SPLIT MSW OA CONTROLLER 0.556162 0.051906
SPLIT MNW OA CONTROLLER 0.505233 0.051906
SPLIT MSE OA CONTROLLER 0.495304 0.051906
SPLIT MNE OA CONTROLLER 0.378116 0.051906
SPLIT MN1 OA CONTROLLER 0.309122 0.051906
SPLIT MN2 OA CONTROLLER 0.306857 0.051906
SPLIT MS1 OA CONTROLLER 0.376339 0.051906
SPLIT MS2 OA CONTROLLER 0.377787 0.051906
SPLIT TSW OA CONTROLLER 0.367339 0.025953
SPLIT TNW OA CONTROLLER 0.329448 0.025953
SPLIT TSE OA CONTROLLER 0.341712 0.025953
SPLIT TNE OA CONTROLLER 0.256395 0.025953
SPLIT TN1 OA CONTROLLER 0.204661 0.025953
SPLIT TN2 OA CONTROLLER 0.202377 0.025953
SPLIT TS1 OA CONTROLLER 0.282018 0.025953
SPLIT TS2 OA CONTROLLER 0.282954 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.200303 3315.72 0.798655
SPLIT GNW COOLING COIL 0.183703 3040.94 0.798655
SPLIT OFFICE COOLING COIL 0.485502 8036.78 0.798655
SPLIT GNE COOLING COIL 0.127648 2113.03 0.798655
SPLIT GN1 COOLING COIL 0.106134 1756.90 0.798655
SPLIT GN2 COOLING COIL 0.104811 1734.99 0.798655
SPLIT GS1 COOLING COIL 0.128055 2119.77 0.798655
SPLIT GS2 COOLING COIL 0.131484 2176.53 0.798655
SPLIT MSW COOLING COIL 0.556162 9206.45 0.798655
SPLIT MNW COOLING COIL 0.505233 8363.39 0.798655
SPLIT MSE COOLING COIL 0.495304 8199.04 0.798655
SPLIT MNE COOLING COIL 0.378116 6259.16 0.798655
SPLIT MN1 COOLING COIL 0.309122 5117.06 0.798655
SPLIT MN2 COOLING COIL 0.306857 5079.57 0.798655
SPLIT MS1 COOLING COIL 0.376339 6229.75 0.798655
SPLIT MS2 COOLING COIL 0.377787 6253.72 0.798655
SPLIT TSW COOLING COIL 0.367339 6080.76 0.798655
SPLIT TNW COOLING COIL 0.329448 5453.53 0.798655
SPLIT TSE COOLING COIL 0.341712 5656.54 0.798655
SPLIT TNE COOLING COIL 0.256395 4244.24 0.798655
SPLIT TN1 COOLING COIL 0.204661 3387.86 0.798655
SPLIT TN2 COOLING COIL 0.202377 3350.06 0.798655
SPLIT TS1 COOLING COIL 0.282018 4668.40 0.798655
SPLIT TS2 COOLING COIL 0.282954 4683.89 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.200303 0.200303 0.200303 0.200303 3715.45 3315.72 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.183703 0.183703 0.183703 0.183703 3650.10 3040.94 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.485502 0.485502 0.485502 0.485502 6578.63 8036.78 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.127648 0.127648 0.127648 0.127648 3638.22 2113.03 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.106134 0.106134 0.106134 0.106134 2785.46 1756.90 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.104811 0.104811 0.104811 0.104811 2785.18 1734.99 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.128055 0.128055 0.128055 0.128055 2805.01 2119.77 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.131484 0.131484 0.131484 0.131484 2940.84 2176.53 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.556162 0.556162 0.556162 0.556162 7233.34 9206.45 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.505233 0.505233 0.505233 0.505233 7190.91 8363.39 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.495304 0.495304 0.495304 0.495304 7202.18 8199.04 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.378116 0.378116 0.378116 0.378116 7159.71 6259.16 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.309122 0.309122 0.309122 0.309122 5079.33 5117.06 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.306857 0.306857 0.306857 0.306857 5078.58 5079.57 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.376339 0.376339 0.376339 0.376339 5124.95 6229.75 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.377787 0.377787 0.377787 0.377787 5124.21 6253.72 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.367339 0.367339 0.367339 0.367339 5405.92 6080.76 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.329448 0.329448 0.329448 0.329448 5385.11 5453.53 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.341712 0.341712 0.341712 0.341712 5389.39 5656.54 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.256395 0.256395 0.256395 0.256395 5368.56 4244.24 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.204661 0.204661 0.204661 0.204661 4288.08 3387.86 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.202377 0.202377 0.202377 0.202377 4287.66 3350.06 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.282018 0.282018 0.282018 0.282018 4307.84 4668.40 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.282954 0.282954 0.282954 0.282954 4307.43 4683.89 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.200303
SPLIT GNW SUPPLY FAN 0.183703
SPLIT OFFICE SUPPLY FAN 0.485502
SPLIT GNE SUPPLY FAN 0.127648
SPLIT GN1 SUPPLY FAN 0.106134
SPLIT GN2 SUPPLY FAN 0.104811
SPLIT GS1 SUPPLY FAN 0.128055
SPLIT GS2 SUPPLY FAN 0.131484
SPLIT MSW SUPPLY FAN 0.556162
SPLIT MNW SUPPLY FAN 0.505233
SPLIT MSE SUPPLY FAN 0.495304
SPLIT MNE SUPPLY FAN 0.378116
SPLIT MN1 SUPPLY FAN 0.309122
SPLIT MN2 SUPPLY FAN 0.306857
SPLIT MS1 SUPPLY FAN 0.376339
SPLIT MS2 SUPPLY FAN 0.377787
SPLIT TSW SUPPLY FAN 0.367339
SPLIT TNW SUPPLY FAN 0.329448
SPLIT TSE SUPPLY FAN 0.341712
SPLIT TNE SUPPLY FAN 0.256395
SPLIT TN1 SUPPLY FAN 0.204661
SPLIT TN2 SUPPLY FAN 0.202377
SPLIT TS1 SUPPLY FAN 0.282018
SPLIT TS2 SUPPLY FAN 0.282954


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 3715.45
SPLIT GNW HEATING COIL 3650.10
SPLIT OFFICE HEATING COIL 6578.63
SPLIT GNE HEATING COIL 3638.22
SPLIT GN1 HEATING COIL 2785.46
SPLIT GN2 HEATING COIL 2785.18
SPLIT GS1 HEATING COIL 2805.01
SPLIT GS2 HEATING COIL 2940.84
SPLIT MSW HEATING COIL 7233.34
SPLIT MNW HEATING COIL 7190.91
SPLIT MSE HEATING COIL 7202.18
SPLIT MNE HEATING COIL 7159.71
SPLIT MN1 HEATING COIL 5079.33
SPLIT MN2 HEATING COIL 5078.58
SPLIT MS1 HEATING COIL 5124.95
SPLIT MS2 HEATING COIL 5124.21
SPLIT TSW HEATING COIL 5405.92
SPLIT TNW HEATING COIL 5385.11
SPLIT TSE HEATING COIL 5389.39
SPLIT TNE HEATING COIL 5368.56
SPLIT TN1 HEATING COIL 4288.08
SPLIT TN2 HEATING COIL 4287.66
SPLIT TS1 HEATING COIL 4307.84
SPLIT TS2 HEATING COIL 4307.43



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:20:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -8.8
February 21.89 -2.2
March 21.92 0.30
April 22.31 6.67
May 22.73 10.10
June 24.03 16.46
July 24.33 20.57
August 24.29 19.17
September 23.85 14.69
October 22.67 8.64
November 21.99 2.84
December 21.72 -4.1
     
Annual Sum or Average 22.79 7.07
Minimum of Months 21.72 -8.8
Maximum of Months 24.33 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.72 -2.2
March 21.73 0.30
April 22.00 6.67
May 22.53 10.10
June 23.99 16.46
July 24.32 20.57
August 24.25 19.17
September 23.65 14.69
October 22.16 8.64
November 21.75 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.63 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.32 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.23 -8.8
February 20.21 -2.2
March 20.97 0.30
April 22.21 6.67
May 22.85 10.10
June 23.80 16.46
July 23.89 20.57
August 23.89 19.17
September 23.72 14.69
October 22.89 8.64
November 21.46 2.84
December 19.77 -4.1
     
Annual Sum or Average 22.08 7.07
Minimum of Months 19.23 -8.8
Maximum of Months 23.89 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.70 -2.2
March 21.71 0.30
April 21.95 6.67
May 22.43 10.10
June 23.95 16.46
July 24.30 20.57
August 24.23 19.17
September 23.60 14.69
October 22.06 8.64
November 21.72 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.59 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.30 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.70 -2.2
March 21.71 0.30
April 21.88 6.67
May 22.33 10.10
June 23.95 16.46
July 24.31 20.57
August 24.25 19.17
September 23.68 14.69
October 22.09 8.64
November 21.74 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.59 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.31 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.70 -2.2
March 21.71 0.30
April 21.88 6.67
May 22.33 10.10
June 23.95 16.46
July 24.31 20.57
August 24.25 19.17
September 23.68 14.69
October 22.08 8.64
November 21.74 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.59 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.31 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -8.8
February 21.90 -2.2
March 21.92 0.30
April 22.25 6.67
May 22.60 10.10
June 24.04 16.46
July 24.34 20.57
August 24.31 19.17
September 23.97 14.69
October 22.76 8.64
November 22.05 2.84
December 21.74 -4.1
     
Annual Sum or Average 22.80 7.07
Minimum of Months 21.73 -8.8
Maximum of Months 24.34 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -8.8
February 21.90 -2.2
March 21.92 0.30
April 22.25 6.67
May 22.61 10.10
June 24.03 16.46
July 24.33 20.57
August 24.31 19.17
September 23.97 14.69
October 22.76 8.64
November 22.05 2.84
December 21.74 -4.1
     
Annual Sum or Average 22.81 7.07
Minimum of Months 21.73 -8.8
Maximum of Months 24.33 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 -8.8
February 22.22 -2.2
March 22.53 0.30
April 23.44 6.67
May 23.74 10.10
June 24.36 16.46
July 24.40 20.57
August 24.38 19.17
September 24.17 14.69
October 23.87 8.64
November 22.85 2.84
December 21.84 -4.1
     
Annual Sum or Average 23.31 7.07
Minimum of Months 21.84 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.80 -2.2
March 21.88 0.30
April 22.97 6.67
May 23.54 10.10
June 24.35 16.46
July 24.40 20.57
August 24.37 19.17
September 23.95 14.69
October 23.26 8.64
November 22.01 2.84
December 21.70 -4.1
     
Annual Sum or Average 23.00 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.85 -8.8
February 22.20 -2.2
March 22.54 0.30
April 23.40 6.67
May 23.72 10.10
June 24.35 16.46
July 24.40 20.57
August 24.38 19.17
September 24.17 14.69
October 23.83 8.64
November 22.81 2.84
December 21.82 -4.1
     
Annual Sum or Average 23.29 7.07
Minimum of Months 21.82 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.78 -2.2
March 21.83 0.30
April 22.88 6.67
May 23.45 10.10
June 24.33 16.46
July 24.39 20.57
August 24.37 19.17
September 23.92 14.69
October 23.12 8.64
November 21.92 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.96 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.39 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -8.8
February 21.80 -2.2
March 21.88 0.30
April 23.09 6.67
May 23.52 10.10
June 24.37 16.46
July 24.40 20.57
August 24.39 19.17
September 24.06 14.69
October 23.46 8.64
November 22.14 2.84
December 21.72 -4.1
     
Annual Sum or Average 23.05 7.07
Minimum of Months 21.71 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -8.8
February 21.80 -2.2
March 21.88 0.30
April 23.08 6.67
May 23.51 10.10
June 24.37 16.46
July 24.40 20.57
August 24.39 19.17
September 24.06 14.69
October 23.45 8.64
November 22.13 2.84
December 21.72 -4.1
     
Annual Sum or Average 23.05 7.07
Minimum of Months 21.71 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 -8.8
February 22.42 -2.2
March 22.86 0.30
April 23.68 6.67
May 23.83 10.10
June 24.38 16.46
July 24.40 20.57
August 24.39 19.17
September 24.28 14.69
October 24.11 8.64
November 23.24 2.84
December 22.03 -4.1
     
Annual Sum or Average 23.48 7.07
Minimum of Months 22.03 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 -8.8
February 22.42 -2.2
March 22.87 0.30
April 23.68 6.67
May 23.83 10.10
June 24.38 16.46
July 24.40 20.57
August 24.39 19.17
September 24.28 14.69
October 24.10 8.64
November 23.24 2.84
December 22.03 -4.1
     
Annual Sum or Average 23.48 7.07
Minimum of Months 22.03 -8.8
Maximum of Months 24.40 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 -8.8
February 22.06 -2.2
March 22.22 0.30
April 22.80 6.67
May 23.37 10.10
June 24.07 16.46
July 24.34 20.57
August 24.25 19.17
September 23.70 14.69
October 23.00 8.64
November 22.27 2.84
December 21.77 -4.1
     
Annual Sum or Average 22.97 7.07
Minimum of Months 21.77 -8.8
Maximum of Months 24.34 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.79 -2.2
March 21.88 0.30
April 22.53 6.67
May 23.23 10.10
June 24.05 16.46
July 24.32 20.57
August 24.21 19.17
September 23.50 14.69
October 22.50 8.64
November 21.82 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.77 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.32 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 -8.8
February 22.06 -2.2
March 22.23 0.30
April 22.83 6.67
May 23.38 10.10
June 24.08 16.46
July 24.33 20.57
August 24.25 19.17
September 23.72 14.69
October 23.00 8.64
November 22.24 2.84
December 21.75 -4.1
     
Annual Sum or Average 22.98 7.07
Minimum of Months 21.75 -8.8
Maximum of Months 24.33 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.76 -2.2
March 21.83 0.30
April 22.52 6.67
May 23.19 10.10
June 24.02 16.46
July 24.29 20.57
August 24.19 19.17
September 23.48 14.69
October 22.40 8.64
November 21.76 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.74 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.29 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.76 -2.2
March 21.83 0.30
April 22.48 6.67
May 23.19 10.10
June 24.07 16.46
July 24.32 20.57
August 24.22 19.17
September 23.50 14.69
October 22.46 8.64
November 21.80 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.76 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.32 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -8.8
February 21.76 -2.2
March 21.82 0.30
April 22.48 6.67
May 23.19 10.10
June 24.06 16.46
July 24.32 20.57
August 24.22 19.17
September 23.50 14.69
October 22.45 8.64
November 21.79 2.84
December 21.70 -4.1
     
Annual Sum or Average 22.76 7.07
Minimum of Months 21.70 -8.8
Maximum of Months 24.32 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 -8.8
February 22.14 -2.2
March 22.30 0.30
April 22.89 6.67
May 23.43 10.10
June 24.14 16.46
July 24.35 20.57
August 24.29 19.17
September 23.80 14.69
October 23.18 8.64
November 22.42 2.84
December 21.82 -4.1
     
Annual Sum or Average 23.05 7.07
Minimum of Months 21.82 -8.8
Maximum of Months 24.35 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 -8.8
February 22.14 -2.2
March 22.30 0.30
April 22.89 6.67
May 23.43 10.10
June 24.14 16.46
July 24.35 20.57
August 24.29 19.17
September 23.80 14.69
October 23.18 8.64
November 22.42 2.84
December 21.82 -4.1
     
Annual Sum or Average 23.05 7.07
Minimum of Months 21.82 -8.8
Maximum of Months 24.35 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.38 -8.8
February 21.39 -2.2
March 21.96 0.30
April 23.33 6.67
May 24.42 10.10
June 26.02 16.46
July 26.67 20.57
August 26.36 19.17
September 25.15 14.69
October 23.49 8.64
November 21.93 2.84
December 20.82 -4.1
     
Annual Sum or Average 23.50 7.07
Minimum of Months 20.38 -8.8
Maximum of Months 26.67 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 18.67 -8.8
February 19.76 -2.2
March 20.31 0.30
April 21.53 6.67
May 22.35 10.10
June 24.98 16.46
July 25.96 20.57
August 25.71 19.17
September 24.74 14.69
October 22.27 8.64
November 20.76 2.84
December 19.43 -4.1
     
Annual Sum or Average 22.22 7.07
Minimum of Months 18.67 -8.8
Maximum of Months 25.96 20.57



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:20:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 -8.8
February 23.37 -2.2
March 23.92 0.30
April 25.16 6.67
May 25.64 10.10
June 26.78 16.46
July 27.02 20.57
August 26.91 19.17
September 26.36 14.69
October 25.59 8.64
November 24.12 2.84
December 22.96 -4.1
     
Annual Sum or Average 25.06 7.07
Minimum of Months 22.77 -8.8
Maximum of Months 27.02 20.57



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.123525E+12 75664.040 13-JAN-18:30 8572.775 26456.413 7884.957 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 30241.565 0.000 0.000 0.000
February 0.112219E+12 78219.550 27-FEB-18:15 8572.775 26456.413 7884.957 0.000 1428.242 2508.330 0.000 0.000 0.000 0.000 0.000 31368.833 0.000 0.000 0.000
March 0.123409E+12 76353.012 01-MAR-18:00 8572.775 26456.413 7884.957 0.000 687.668 2508.330 0.000 0.000 0.000 0.000 0.000 30242.869 0.000 0.000 0.000
April 0.119251E+12 76356.112 25-APR-17:30 8572.775 26456.413 7884.957 0.000 6631.870 0.000 0.000 0.000 0.000 0.000 0.000 26810.096 0.000 0.000 0.000
May 0.124061E+12 80749.224 19-MAY-17:30 8572.775 26456.413 7884.957 0.000 14992.641 0.000 0.000 0.000 0.000 0.000 0.000 22842.438 0.000 0.000 0.000
June 0.127217E+12 87809.513 20-JUN-17:15 8572.775 26456.413 7884.957 0.000 18438.609 0.000 0.000 0.000 0.000 0.000 0.000 26456.758 0.000 0.000 0.000
July 0.137688E+12 89034.218 31-JUL-17:30 8572.775 26456.413 7884.957 0.000 19147.326 0.000 0.000 0.000 0.000 0.000 0.000 26972.747 0.000 0.000 0.000
August 0.134057E+12 91049.636 07-AUG-17:30 8572.775 26456.413 7884.957 0.000 19649.155 0.000 0.000 0.000 0.000 0.000 0.000 28486.336 0.000 0.000 0.000
September 0.122791E+12 84212.475 02-SEP-17:30 8572.775 26456.413 7884.957 0.000 20468.647 0.000 0.000 0.000 0.000 0.000 0.000 20829.683 0.000 0.000 0.000
October 0.120490E+12 74748.018 19-OCT-17:45 8572.775 26456.413 7884.957 0.000 3085.541 2508.330 0.000 0.000 0.000 0.000 0.000 26240.002 0.000 0.000 0.000
November 0.116479E+12 74519.210 03-NOV-17:15 8572.775 26456.413 7884.957 0.000 2393.963 2508.330 0.000 0.000 0.000 0.000 0.000 26702.773 0.000 0.000 0.000
December 0.122057E+12 73317.216 19-DEC-18:00 8572.775 26456.413 7884.957 0.000 0.000 2508.330 0.000 0.000 0.000 0.000 0.000 27894.741 0.000 0.000 0.000
                                     
Annual Sum or Average 0.148324E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.112219E+12 73317.216   8572.775 26456.413 7884.957 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 20829.683 0.000 0.000 0.000
Maximum of Months 0.137688E+12 91049.636   8572.775 26456.413 7884.957 0.000 20468.647 2508.330 0.000 0.000 0.000 0.000 0.000 31368.833 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:20:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.135734E+12 127311.206 10-JAN-23:15 127311.206 0.000 0.000 0.000 0.000 0.000 127311.206
February 0.724979E+11 94640.483 04-FEB-02:00 94640.483 0.000 0.000 0.000 0.000 0.000 94640.483
March 0.502315E+11 92815.240 05-MAR-00:15 92815.240 0.000 0.000 0.000 0.000 0.000 92815.240
April 0.151799E+11 48345.307 29-APR-04:00 48345.307 0.000 0.000 0.000 0.000 0.000 48345.307
May 0.104610E+11 39591.791 08-MAY-03:00 39591.791 0.000 0.000 0.000 0.000 0.000 39591.791
June 0.200628E+09 8342.250 17-JUN-03:00 8342.250 0.000 0.000 0.000 0.000 0.000 8342.250
July 91233.415 60.106 08-JUL-04:30 60.106 0.000 0.000 0.000 0.000 0.000 60.106
August 0.115558E+09 4665.820 18-AUG-04:00 4665.820 0.000 0.000 0.000 0.000 0.000 4665.820
September 0.192982E+10 13410.348 19-SEP-02:00 13410.348 0.000 0.000 0.000 0.000 0.000 13410.348
October 0.959378E+10 36194.055 10-OCT-06:15 36194.055 0.000 0.000 0.000 0.000 0.000 36194.055
November 0.438732E+11 82044.718 27-NOV-03:00 82044.718 0.000 0.000 0.000 0.000 0.000 82044.718
December 0.978663E+11 114715.315 31-DEC-07:30 114715.315 0.000 0.000 0.000 0.000 0.000 114715.315
                     
Annual Sum or Average 0.437684E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 91233.415 60.106   60.106 0.000 0.000 0.000 0.000 0.000 60.106
Maximum of Months 0.135734E+12 127311.206   127311.206 0.000 0.000 0.000 0.000 0.000 127311.206