Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904
Simulation Timestamp: 2018-10-19 09:20:31
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1389.81 | 443.37 | 492.14 |
Net Site Energy | 1389.81 | 443.37 | 492.14 |
Total Source Energy | 4387.40 | 1399.66 | 1553.62 |
Net Source Energy | 4387.40 | 1399.66 | 1553.62 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 6.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 119.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 181.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 366.52 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1383.03 | 6.78 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 6.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 119.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 181.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 366.52 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 236.25 | 2.40 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 489.75 | 2.40 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 212.84 | 2.16 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 441.21 | 2.16 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1383.03 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1383.03 | 100.00 |
Total On-Site and Utility Electric Sources | 1383.03 | 100.00 |
Total Electricity End Uses | 1383.03 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 20.25 |
Time Setpoint Not Met During Occupied Cooling | 19.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 364.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Weather File | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Latitude [deg] | 32.58 |
Longitude [deg] | -117.0 |
Elevation [m] | 159.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-SEP-17:30 | 30-MAR-02:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 14058.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 13788.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5758.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 22172.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 76747.59 | 14058.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 14058.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 13788.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7168.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1404.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 5758.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 22172.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 7.34 | 0.00 | 0.00 | 0.00 |
Cooling | 377.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 124.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 575.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1160.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4380.06 | 7.34 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 2.60 | 0.00 | 0.00 | 0.00 |
Cooling | 133.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 203.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 411.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1551.02 | 2.60 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 2.60 | 0.00 | 0.00 | 0.00 |
Cooling | 133.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 203.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 411.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1551.02 | 2.60 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00 | 3.80 | Wetbulb [C] | 3.00 | 120.00 |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30 | 8.90 | 18.40 | Wetbulb [C] | 4.10 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.55 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.848 | 0.287 | 0.200 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.848 | 0.287 | 0.200 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.848 | 0.287 | 0.200 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.848 | 0.287 | 0.200 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.848 | 0.287 | 0.200 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.62_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.848 | 0.287 | 0.200 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.62_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.848 | 0.287 | 0.200 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.62_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.848 | 0.287 | 0.200 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.62_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.848 | 0.287 | 0.200 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.62_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.848 | 0.287 | 0.200 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.848 | 0.287 | 0.200 | ||||||||||||
North Total or Average | 112.97 | 2.848 | 0.287 | 0.200 | ||||||||||||
Non-North Total or Average | 193.95 | 2.848 | 0.287 | 0.200 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW14 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.77 | 83.77 | 39.44 | |
Exterior Lighting Total | 2508.33 | 39.44 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2468.85 | 1967.16 | 501.70 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2259.51 | 1804.57 | 454.94 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7076.98 | 5652.07 | 1424.91 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1729.50 | 1381.27 | 348.23 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1389.20 | 1097.67 | 291.53 | 0.79 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1378.14 | 1088.54 | 289.60 | 0.79 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1670.39 | 1298.61 | 371.78 | 0.78 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1717.20 | 1337.33 | 379.87 | 0.78 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6549.17 | 5230.53 | 1318.64 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6030.69 | 4816.44 | 1214.25 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5745.13 | 4583.67 | 1161.46 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4855.53 | 3877.89 | 977.64 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3837.87 | 3064.01 | 773.86 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3818.02 | 3047.58 | 770.44 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4538.16 | 3584.55 | 953.62 | 0.79 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4554.27 | 3597.85 | 956.42 | 0.79 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4210.92 | 3363.07 | 847.85 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3827.76 | 3057.06 | 770.70 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3792.87 | 3029.19 | 763.67 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3051.75 | 2432.67 | 619.09 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2472.37 | 1953.78 | 518.59 | 0.79 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2474.52 | 1955.57 | 518.95 | 0.79 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3136.98 | 2503.74 | 633.25 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3143.28 | 2510.40 | 632.88 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2352.6 | 3.13 | 10.68 | 11.10 | 10.39 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2152.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6741.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1647.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1324.9 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1314.4 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1595.8 | 3.16 | 10.80 | 11.22 | 10.56 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1640.2 | 3.16 | 10.79 | 11.22 | 10.55 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6239.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5745.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5473.7 | 3.13 | 10.68 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4625.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3656.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3637.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4328.4 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4343.7 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4011.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3646.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3613.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2907.9 | 3.13 | 10.68 | 11.10 | 10.39 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2358.0 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2360.0 | 3.14 | 10.72 | 11.14 | 10.45 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2988.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2994.5 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 1475.74 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 2489.99 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2847.74 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 1823.72 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 1821.15 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 1827.14 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 1824.58 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 1423.87 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 166.21 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 152.89 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 478.87 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 117.03 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 91.83 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 91.02 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 106.50 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.10 | 109.92 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 443.15 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 408.07 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 387.88 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.55 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 259.48 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 258.04 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 299.74 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 300.91 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 284.93 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 259.01 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 256.65 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.18 | 205.65 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 163.47 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 163.63 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 211.97 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 212.69 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1549.72 | 1859.67 | 0.124 | 0.148 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:45:00 | 30.23 | 0.00820 |
G NW APARTMENT | 1425.55 | 1710.66 | 0.114 | 0.136 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:30:00 | 29.61 | 0.00820 |
OFFICE | 4250.34 | 5100.40 | 0.356 | 0.428 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:30:00 | 27.16 | 0.00820 |
G NE APARTMENT | 1091.14 | 1309.36 | 0.087 | 0.104 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:45:00 | 27.54 | 0.00820 |
G N1 APARTMENT | 856.18 | 1027.41 | 0.068 | 0.082 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 28.50 | 0.00820 |
G N2 APARTMENT | 848.69 | 1018.42 | 0.068 | 0.081 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 18:30:00 | 28.50 | 0.00820 |
G S1 APARTMENT | 993.02 | 1191.62 | 0.079 | 0.095 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:15:00 | 30.97 | 0.00820 |
G S2 APARTMENT | 1024.85 | 1229.82 | 0.082 | 0.098 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:15:00 | 30.97 | 0.00820 |
M SW APARTMENT | 4131.95 | 4958.35 | 0.330 | 0.396 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:45:00 | 30.23 | 0.00820 |
M NW APARTMENT | 3804.85 | 4565.82 | 0.304 | 0.364 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:30:00 | 29.61 | 0.00820 |
M SE APARTMENT | 3616.59 | 4339.91 | 0.289 | 0.346 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 30.86 | 0.00820 |
M NE APARTMENT | 3063.37 | 3676.04 | 0.244 | 0.293 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:45:00 | 27.54 | 0.00820 |
M N1 APARTMENT | 2419.43 | 2903.32 | 0.193 | 0.232 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 18:15:00 | 28.83 | 0.00820 |
M N2 APARTMENT | 2405.91 | 2887.10 | 0.192 | 0.230 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 18:15:00 | 28.83 | 0.00820 |
M S1 APARTMENT | 2794.74 | 3353.69 | 0.223 | 0.268 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:15:00 | 30.97 | 0.00820 |
M S2 APARTMENT | 2805.66 | 3366.79 | 0.224 | 0.269 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:15:00 | 30.97 | 0.00820 |
T SW APARTMENT | 2656.72 | 3188.06 | 0.212 | 0.254 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 31.03 | 0.00820 |
T NW APARTMENT | 2414.97 | 2897.97 | 0.193 | 0.231 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:45:00 | 30.23 | 0.00820 |
T SE APARTMENT | 2392.96 | 2871.55 | 0.191 | 0.229 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:15:00 | 30.97 | 0.00820 |
T NE APARTMENT | 1917.44 | 2300.93 | 0.153 | 0.184 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 31.19 | 0.00820 |
T N1 APARTMENT | 1524.18 | 1829.01 | 0.122 | 0.146 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 31.30 | 0.00820 |
T N2 APARTMENT | 1525.65 | 1830.78 | 0.122 | 0.146 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 31.30 | 0.00820 |
T S1 APARTMENT | 1976.36 | 2371.63 | 0.158 | 0.189 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:45:00 | 31.19 | 0.00820 |
T S2 APARTMENT | 1983.13 | 2379.76 | 0.158 | 0.190 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 31.08 | 0.00820 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 512.77 | 615.33 | 0.015 | 0.027 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
G NW APARTMENT | 509.99 | 611.99 | 0.015 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
OFFICE | 1471.68 | 1766.02 | 0.041 | 0.050 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 3.80 | 0.00506 |
G NE APARTMENT | 512.04 | 614.44 | 0.015 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
G N1 APARTMENT | 225.49 | 270.59 | 0.007 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
G N2 APARTMENT | 225.54 | 270.65 | 0.007 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
G S1 APARTMENT | 229.50 | 275.40 | 0.007 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
G S2 APARTMENT | 288.48 | 346.18 | 0.008 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
M SW APARTMENT | 769.99 | 923.99 | 0.023 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
M NW APARTMENT | 760.49 | 912.58 | 0.022 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
M SE APARTMENT | 776.00 | 931.20 | 0.023 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
M NE APARTMENT | 766.58 | 919.89 | 0.022 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
M N1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00506 | |
M N2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00506 | |
M S1 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00506 | |
M S2 APARTMENT | 0.00 | 0.00 | 0.000 | 0.052 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00506 | |
T SW APARTMENT | 1075.73 | 1290.87 | 0.032 | 0.038 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T NW APARTMENT | 1073.56 | 1288.27 | 0.031 | 0.038 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T SE APARTMENT | 1078.62 | 1294.34 | 0.032 | 0.038 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T NE APARTMENT | 1076.45 | 1291.74 | 0.032 | 0.038 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T N1 APARTMENT | 710.73 | 852.87 | 0.021 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T N2 APARTMENT | 710.81 | 852.98 | 0.021 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T S1 APARTMENT | 711.35 | 853.62 | 0.021 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
T S2 APARTMENT | 711.44 | 853.72 | 0.021 | 0.026 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | 3.80 | 0.00506 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT GNW | 0.14 | 0.14 | 0.03 | 0.03 |
SPLIT OFFICE | 0.43 | 0.43 | 0.05 | 0.05 |
SPLIT GNE | 0.10 | 0.10 | 0.03 | 0.03 |
SPLIT GN1 | 0.08 | 0.08 | 0.03 | 0.03 |
SPLIT GN2 | 0.08 | 0.08 | 0.03 | 0.03 |
SPLIT GS1 | 0.10 | 0.10 | 0.03 | 0.03 |
SPLIT GS2 | 0.10 | 0.10 | 0.03 | 0.03 |
SPLIT MSW | 0.40 | 0.40 | 0.05 | 0.05 |
SPLIT MNW | 0.36 | 0.36 | 0.05 | 0.05 |
SPLIT MSE | 0.35 | 0.35 | 0.05 | 0.05 |
SPLIT MNE | 0.29 | 0.29 | 0.05 | 0.05 |
SPLIT MN1 | 0.23 | 0.23 | 0.05 | 0.05 |
SPLIT MN2 | 0.23 | 0.23 | 0.05 | 0.05 |
SPLIT MS1 | 0.27 | 0.27 | 0.05 | 0.05 |
SPLIT MS2 | 0.27 | 0.27 | 0.05 | 0.05 |
SPLIT TSW | 0.25 | 0.25 | 0.04 | 0.04 |
SPLIT TNW | 0.23 | 0.23 | 0.04 | 0.04 |
SPLIT TSE | 0.23 | 0.23 | 0.04 | 0.04 |
SPLIT TNE | 0.18 | 0.18 | 0.04 | 0.04 |
SPLIT TN1 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT TN2 | 0.15 | 0.15 | 0.03 | 0.03 |
SPLIT TS1 | 0.19 | 0.19 | 0.03 | 0.03 |
SPLIT TS2 | 0.19 | 0.19 | 0.03 | 0.03 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2702.75 | 5057.50 | 182.25 |
G NW APARTMENT | 2522.25 | 5796.25 | 247.50 |
OFFICE | 132.75 | 1431.75 | 0.00 |
G NE APARTMENT | 2438.00 | 6029.00 | 328.75 |
G N1 APARTMENT | 2374.75 | 6096.75 | 343.25 |
G N2 APARTMENT | 2362.25 | 6105.50 | 346.50 |
G S1 APARTMENT | 2529.25 | 5479.25 | 244.50 |
G S2 APARTMENT | 2479.00 | 5523.25 | 272.50 |
M SW APARTMENT | 5746.50 | 495.75 | 0.00 |
M NW APARTMENT | 4855.75 | 1383.00 | 1.00 |
M SE APARTMENT | 5750.75 | 533.50 | 0.00 |
M NE APARTMENT | 4802.25 | 1470.50 | 2.00 |
M N1 APARTMENT | 4915.50 | 1074.75 | 2.00 |
M N2 APARTMENT | 4912.50 | 1079.50 | 2.00 |
M S1 APARTMENT | 5853.75 | 236.50 | 0.00 |
M S2 APARTMENT | 5853.00 | 239.50 | 0.00 |
T SW APARTMENT | 4400.25 | 2420.00 | 12.00 |
T NW APARTMENT | 3701.50 | 3439.00 | 21.25 |
T SE APARTMENT | 4393.50 | 2425.00 | 13.00 |
T NE APARTMENT | 3659.25 | 3586.50 | 37.50 |
T N1 APARTMENT | 3648.25 | 3481.25 | 32.25 |
T N2 APARTMENT | 3637.75 | 3489.00 | 32.50 |
T S1 APARTMENT | 4501.50 | 2113.50 | 13.75 |
T S2 APARTMENT | 4500.50 | 2118.00 | 13.75 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6192.25 | 6238.25 | 364.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
G NW APARTMENT | 6.50 | 0.00 | 6.50 | 0.00 |
OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 8.25 | 0.00 | 8.25 | 0.00 |
G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G S1 APARTMENT | 0.00 | 3.75 | 0.00 | 3.75 |
G S2 APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 0.00 | 11.25 | 0.00 | 11.25 |
M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 0.00 | 18.50 | 0.00 | 18.50 |
M S2 APARTMENT | 0.00 | 18.50 | 0.00 | 18.50 |
T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 0.00 | 6.25 | 0.00 | 6.25 |
T NE APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T N1 APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T N2 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T S1 APARTMENT | 0.25 | 10.25 | 0.25 | 10.25 |
T S2 APARTMENT | 0.25 | 10.75 | 0.25 | 10.75 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 20.25 | 19.00 | 20.25 | 19.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.368 | 0.064 | 0.000 | 0.150 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.064 | 0.000 | 0.145 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.521 | 0.088 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.064 | 0.000 | 0.144 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.039 | 0.000 | 0.142 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.039 | 0.000 | 0.142 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.039 | 0.000 | 0.149 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.039 | 0.000 | 0.149 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.092 | 0.000 | 0.174 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.092 | 0.000 | 0.172 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.092 | 0.000 | 0.174 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.092 | 0.000 | 0.172 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.056 | 0.000 | 0.172 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.056 | 0.000 | 0.172 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.056 | 0.000 | 0.174 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.056 | 0.000 | 0.174 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.200 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.197 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.200 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.197 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.073 | 0.000 | 0.196 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.073 | 0.000 | 0.196 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.073 | 0.000 | 0.200 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.073 | 0.000 | 0.200 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.358 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.508 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.390 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.387 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.390 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.386 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.389 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.389 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.392 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.392 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 366.52 | 0.00 | 01-JAN-00:15 | 32120.45 | 01-JAN-08:00 |
WaterSystems:Electricity | 366.52 | 0.00 | 01-JAN-00:15 | 32120.45 | 01-JAN-08:00 |
Water Heater:WaterSystems:Electricity | 366.52 | 0.00 | 01-JAN-00:15 | 32120.45 | 01-JAN-08:00 |
Fans:Electricity | 181.59 | 5758.08 | 03-JAN-07:15 | 5758.08 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
ElectricityPurchased:Plant | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
Cogeneration:ElectricityPurchased | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
ElectricityNet:Plant | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
Cogeneration:ElectricityNet | 1383.03 | 19128.38 | 01-JAN-03:15 | 76747.59 | 29-SEP-17:30 |
ExteriorLights:Electricity | 39.44 | 0.00 | 01-JAN-07:00 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.44 | 0.00 | 01-JAN-07:00 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 300.65 | 5758.08 | 03-JAN-07:15 | 24684.91 | 29-SEP-13:00 |
General:Fans:Electricity | 181.59 | 5758.08 | 03-JAN-07:15 | 5758.08 | 01-JAN-00:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 119.06 | 0.00 | 01-JAN-00:15 | 18926.83 | 29-SEP-13:00 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 6.78 | 0.00 | 01-JAN-10:00 | 14058.44 | 30-MAR-03:00 |
Gas:HVAC | 6.78 | 0.00 | 01-JAN-10:00 | 14058.44 | 30-MAR-03:00 |
Heating:Gas | 6.78 | 0.00 | 01-JAN-10:00 | 14058.44 | 30-MAR-03:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 984.60 | 1593.79 | 18-DEC-07:15 | 124631.61 | 29-SEP-15:15 |
EnergyTransfer:Building | 490.56 | 1533.19 | 18-DEC-07:15 | 55201.37 | 29-SEP-15:15 |
EnergyTransfer:Zone:G SW APARTMENT | 8.52 | 0.00 | 06-OCT-04:00 | 1901.48 | 29-SEP-15:30 |
Heating:EnergyTransfer | 2.04 | 0.00 | 01-JAN-07:30 | 5566.65 | 30-MAR-03:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.05 | 0.00 | 01-JAN-00:15 | 283.69 | 30-MAR-03:00 |
Cooling:EnergyTransfer | 488.52 | 727.40 | 11-FEB-16:00 | 55201.37 | 29-SEP-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 8.47 | 0.00 | 01-JAN-00:30 | 1901.48 | 29-SEP-15:30 |
EnergyTransfer:Zone:G NW APARTMENT | 6.20 | 0.00 | 27-OCT-15:15 | 1370.88 | 29-SEP-16:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.26 | 0.00 | 01-JAN-06:15 | 312.87 | 30-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 5.95 | 0.00 | 01-JAN-00:15 | 1370.88 | 29-SEP-16:15 |
EnergyTransfer:Zone:OFFICE | 22.97 | 0.01 | 22-MAY-01:15 | 3192.26 | 16-OCT-12:15 |
Heating:EnergyTransfer:Zone:OFFICE | 0.16 | 0.00 | 01-JAN-00:15 | 262.49 | 12-FEB-04:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 22.81 | 0.00 | 01-JAN-10:00 | 3192.26 | 16-OCT-12:15 |
EnergyTransfer:Zone:G NE APARTMENT | 6.40 | 0.02 | 08-APR-16:00 | 1008.81 | 19-JUL-09:30 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.20 | 0.00 | 01-JAN-06:15 | 360.90 | 30-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.20 | 0.00 | 01-JAN-00:15 | 1008.81 | 19-JUL-09:30 |
EnergyTransfer:Zone:G N1 APARTMENT | 6.15 | 0.00 | 04-OCT-08:30 | 810.87 | 18-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 278.95 | 08-JAN-03:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.05 | 0.00 | 02-JAN-02:30 | 810.87 | 18-JUL-17:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 6.15 | 0.02 | 17-JAN-15:30 | 805.26 | 18-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 300.80 | 08-JAN-04:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.05 | 0.00 | 02-JAN-02:30 | 805.26 | 18-JUL-17:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 8.06 | 0.03 | 05-OCT-03:15 | 1278.54 | 30-SEP-11:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 262.08 | 29-MAR-24:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 8.04 | 0.00 | 15-JAN-08:45 | 1278.54 | 30-SEP-11:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 7.85 | 0.07 | 13-APR-10:45 | 1301.05 | 30-SEP-11:45 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 258.61 | 29-MAR-24:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 7.84 | 0.00 | 15-JAN-08:45 | 1301.05 | 30-SEP-11:45 |
EnergyTransfer:Zone:M SW APARTMENT | 45.87 | 0.01 | 12-FEB-13:30 | 5254.68 | 16-OCT-14:30 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 54.87 | 12-FEB-07:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 45.87 | 0.00 | 11-FEB-16:00 | 5254.68 | 16-OCT-14:30 |
EnergyTransfer:Zone:M NW APARTMENT | 31.79 | 0.14 | 06-FEB-11:15 | 3706.32 | 29-SEP-16:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 149.66 | 18-DEC-08:45 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 31.79 | 0.00 | 03-JAN-11:30 | 3706.32 | 29-SEP-16:15 |
EnergyTransfer:Zone:M SE APARTMENT | 45.41 | 2.48 | 12-FEB-06:30 | 4724.49 | 17-OCT-11:45 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 15.07 | 11-FEB-16:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 45.41 | 0.00 | 11-FEB-16:00 | 4724.49 | 17-OCT-11:45 |
EnergyTransfer:Zone:M NE APARTMENT | 31.40 | 1.56 | 04-JAN-13:00 | 3136.83 | 16-OCT-10:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 9.90 | 04-JAN-13:15 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 31.40 | 0.00 | 04-JAN-13:00 | 3136.83 | 16-OCT-10:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 30.17 | 42.92 | 18-DEC-08:15 | 2413.79 | 18-JUL-17:30 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 30.17 | 42.92 | 18-DEC-08:15 | 2413.79 | 18-JUL-17:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 30.14 | 44.47 | 18-DEC-08:15 | 2402.21 | 18-JUL-17:30 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 30.14 | 44.47 | 18-DEC-08:15 | 2402.21 | 18-JUL-17:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 44.70 | 81.32 | 17-APR-13:45 | 4052.07 | 31-OCT-14:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 44.70 | 81.32 | 17-APR-13:45 | 4052.07 | 31-OCT-14:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 44.67 | 80.36 | 17-APR-13:45 | 4042.39 | 31-OCT-14:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 44.67 | 80.36 | 17-APR-13:45 | 4042.39 | 31-OCT-14:00 |
EnergyTransfer:Zone:T SW APARTMENT | 17.65 | 0.05 | 18-DEC-00:45 | 3289.85 | 16-OCT-13:30 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.16 | 0.00 | 01-JAN-00:15 | 638.96 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 17.49 | 0.00 | 01-JAN-05:00 | 3289.85 | 16-OCT-13:30 |
EnergyTransfer:Zone:T NW APARTMENT | 12.05 | 0.01 | 11-SEP-03:30 | 2455.71 | 29-SEP-15:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.39 | 0.00 | 01-JAN-07:30 | 688.05 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 11.66 | 0.00 | 01-JAN-00:15 | 2455.71 | 29-SEP-15:30 |
EnergyTransfer:Zone:T SE APARTMENT | 17.39 | 0.03 | 17-SEP-06:00 | 3036.84 | 15-OCT-12:30 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.12 | 0.00 | 01-JAN-00:15 | 707.49 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 17.27 | 0.00 | 01-JAN-06:00 | 3036.84 | 15-OCT-12:30 |
EnergyTransfer:Zone:T NE APARTMENT | 11.86 | 0.01 | 18-JAN-08:00 | 2064.37 | 29-SEP-13:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.30 | 0.00 | 01-JAN-07:15 | 767.99 | 30-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 11.56 | 0.00 | 01-JAN-00:15 | 2064.37 | 29-SEP-13:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 10.94 | 0.02 | 23-JAN-11:30 | 1588.89 | 29-SEP-15:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 384.48 | 30-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 10.87 | 0.00 | 02-JAN-02:30 | 1588.89 | 29-SEP-15:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 10.91 | 0.13 | 28-DEC-13:30 | 1583.48 | 29-SEP-14:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 394.64 | 30-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 10.84 | 0.00 | 02-JAN-02:30 | 1583.48 | 29-SEP-14:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 16.65 | 0.01 | 13-FEB-15:00 | 2530.50 | 16-OCT-14:45 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:15 | 317.76 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 16.64 | 0.00 | 03-JAN-03:45 | 2530.50 | 16-OCT-14:45 |
EnergyTransfer:Zone:T S2 APARTMENT | 16.65 | 0.01 | 24-FEB-14:45 | 2535.39 | 16-OCT-14:45 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.02 | 0.00 | 01-JAN-00:15 | 325.86 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 16.63 | 0.00 | 03-JAN-03:45 | 2535.39 | 16-OCT-14:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 494.04 | 0.00 | 17-JAN-06:15 | 69613.90 | 29-SEP-14:15 |
HeatingCoils:EnergyTransfer | 5.42 | 0.00 | 01-JAN-10:00 | 11246.75 | 30-MAR-03:00 |
CoolingCoils:EnergyTransfer | 488.62 | 0.00 | 01-JAN-00:15 | 69613.90 | 29-SEP-14:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.053 | -8.468 | 0.000 | 0.000 | 3.713 | 2.413 | 12.213 | 13.522 | 0.000 | 0.027 | 0.000 | 0.000 | -5.122 | 0.000 | -3.357 | -14.994 |
G NW APARTMENT | 0.257 | -5.948 | 0.000 | 0.000 | 3.770 | 2.413 | 12.213 | 7.217 | 0.000 | 0.029 | 0.000 | 0.000 | -5.017 | 0.000 | -3.091 | -11.843 |
OFFICE | 0.155 | -22.812 | 0.000 | 0.000 | 0.517 | 21.914 | 7.534 | 13.160 | 0.000 | 0.021 | 0.000 | 0.000 | -5.089 | 0.000 | -1.222 | -14.179 |
G NE APARTMENT | 0.204 | -6.200 | 0.000 | 0.000 | 3.790 | 2.413 | 12.213 | 6.726 | 0.000 | 0.029 | 0.000 | 0.000 | -4.850 | 0.000 | -3.057 | -11.268 |
G N1 APARTMENT | 0.102 | -6.052 | 0.000 | 0.000 | 3.792 | 2.413 | 12.213 | 2.366 | 0.000 | 0.024 | 0.000 | 0.000 | -3.026 | 0.000 | -2.511 | -9.322 |
G N2 APARTMENT | 0.101 | -6.049 | 0.000 | 0.000 | 3.793 | 2.413 | 12.213 | 2.365 | 0.000 | 0.024 | 0.000 | 0.000 | -3.023 | 0.000 | -2.509 | -9.329 |
G S1 APARTMENT | 0.013 | -8.043 | 0.000 | 0.000 | 3.716 | 2.413 | 12.213 | 8.753 | 0.000 | 0.020 | 0.000 | 0.000 | -3.133 | 0.000 | -2.821 | -13.130 |
G S2 APARTMENT | 0.014 | -7.838 | 0.000 | 0.000 | 3.717 | 2.413 | 12.213 | 8.754 | 0.000 | 0.020 | 0.000 | 0.000 | -3.128 | 0.000 | -2.822 | -13.344 |
M SW APARTMENT | 0.000 | -45.867 | 0.000 | 0.000 | 3.527 | 2.413 | 12.213 | 12.846 | 0.000 | 0.038 | 25.262 | 0.000 | -5.942 | 0.000 | -4.490 | 0.000 |
M NW APARTMENT | 0.004 | -31.785 | 0.000 | 0.000 | 3.544 | 2.413 | 12.213 | 6.551 | 0.000 | 0.037 | 17.419 | 0.000 | -5.955 | 0.000 | -4.440 | 0.000 |
M SE APARTMENT | 0.000 | -45.411 | 0.000 | 0.000 | 3.530 | 2.413 | 12.213 | 12.453 | 0.000 | 0.037 | 25.130 | 0.000 | -5.878 | 0.000 | -4.488 | 0.000 |
M NE APARTMENT | 0.000 | -31.402 | 0.000 | 0.000 | 3.550 | 2.413 | 12.213 | 6.058 | 0.000 | 0.037 | 17.352 | 0.000 | -5.785 | 0.000 | -4.437 | 0.000 |
M N1 APARTMENT | 0.000 | -30.173 | 0.000 | 0.000 | 3.533 | 2.413 | 12.213 | 1.967 | 0.000 | 0.027 | 17.394 | 0.000 | -3.688 | 0.000 | -3.686 | 0.000 |
M N2 APARTMENT | 0.000 | -30.138 | 0.000 | 0.000 | 3.534 | 2.413 | 12.213 | 1.966 | 0.000 | 0.027 | 17.357 | 0.000 | -3.687 | 0.000 | -3.686 | 0.000 |
M S1 APARTMENT | 0.000 | -44.699 | 0.000 | 0.000 | 3.521 | 2.413 | 12.213 | 8.339 | 0.000 | 0.027 | 25.561 | 0.000 | -3.648 | 0.000 | -3.726 | 0.000 |
M S2 APARTMENT | 0.000 | -44.671 | 0.000 | 0.000 | 3.521 | 2.413 | 12.213 | 8.338 | 0.000 | 0.027 | 25.532 | 0.000 | -3.648 | 0.000 | -3.726 | 0.000 |
T SW APARTMENT | 0.158 | -17.488 | 0.000 | 0.000 | 3.612 | 2.413 | 12.213 | 12.679 | 0.000 | 0.048 | 0.000 | 0.000 | -5.556 | 0.000 | -5.320 | -2.758 |
T NW APARTMENT | 0.392 | -11.658 | 0.000 | 0.000 | 3.649 | 2.413 | 12.213 | 6.482 | 0.000 | 0.048 | 0.000 | 0.000 | -5.481 | 0.000 | -5.155 | -2.902 |
T SE APARTMENT | 0.121 | -17.270 | 0.000 | 0.000 | 3.619 | 2.413 | 12.213 | 12.327 | 0.000 | 0.047 | 0.000 | 0.000 | -5.499 | 0.000 | -5.323 | -2.649 |
T NE APARTMENT | 0.302 | -11.558 | 0.000 | 0.000 | 3.666 | 2.413 | 12.213 | 6.059 | 0.000 | 0.048 | 0.000 | 0.000 | -5.328 | 0.000 | -5.151 | -2.663 |
T N1 APARTMENT | 0.069 | -10.871 | 0.000 | 0.000 | 3.646 | 2.413 | 12.213 | 1.984 | 0.000 | 0.035 | 0.000 | 0.000 | -3.364 | 0.000 | -4.172 | -1.952 |
T N2 APARTMENT | 0.069 | -10.845 | 0.000 | 0.000 | 3.647 | 2.413 | 12.213 | 1.982 | 0.000 | 0.035 | 0.000 | 0.000 | -3.361 | 0.000 | -4.174 | -1.979 |
T S1 APARTMENT | 0.015 | -16.640 | 0.000 | 0.000 | 3.593 | 2.413 | 12.213 | 8.251 | 0.000 | 0.034 | 0.000 | 0.000 | -3.449 | 0.000 | -4.361 | -2.069 |
T S2 APARTMENT | 0.015 | -16.633 | 0.000 | 0.000 | 3.593 | 2.413 | 12.213 | 8.250 | 0.000 | 0.034 | 0.000 | 0.000 | -3.447 | 0.000 | -4.362 | -2.078 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.076 | 0.000 | 0.002 | 0.000 | 0.000 | -0.644 | 0.000 | -0.523 | -15.982 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 0.340 | 0.000 | 0.075 | 0.000 | 0.000 | -1.543 | 0.000 | -12.610 | -9.597 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.073 | 0.000 | 0.002 | 0.000 | 0.000 | -0.716 | 0.000 | -0.435 | -15.994 |
Total Facility | 2.043 | -488.519 | 0.000 | 0.000 | 84.091 | 128.627 | 294.692 | 179.886 | 0.000 | 0.863 | 171.010 | 0.000 | -109.005 | 0.000 | -105.653 | -158.033 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 29-SEP-15:30 | 0.00 | -1901.54 | 0.00 | 0.00 | 48.85 | 100.83 | 470.90 | 1982.18 | 0.00 | 67.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -769.10 |
G NW APARTMENT | 29-SEP-16:08 | 0.00 | -1371.39 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 1189.93 | 0.00 | 48.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -684.78 |
OFFICE | 16-OCT-12:15 | 0.00 | -3192.55 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 2181.08 | 0.00 | 131.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1354.28 |
G NE APARTMENT | 19-JUL-09:30 | 0.00 | -1008.75 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1227.18 | 0.00 | 62.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -756.75 |
G N1 APARTMENT | 18-JUL-17:30 | 0.00 | -810.86 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 350.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.42 | -457.28 |
G N2 APARTMENT | 18-JUL-17:30 | 0.00 | -805.25 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 350.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.42 | -463.03 |
G S1 APARTMENT | 30-SEP-11:30 | 0.00 | -1278.66 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1625.32 | 0.00 | 35.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -858.33 |
G S2 APARTMENT | 30-SEP-11:45 | 0.00 | -1301.09 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1609.98 | 0.00 | 37.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -821.89 |
M SW APARTMENT | 16-OCT-14:30 | 0.00 | -5255.00 | 0.00 | 0.00 | 40.67 | 50.41 | 400.26 | 2268.17 | 0.00 | 79.88 | 2415.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 29-SEP-16:15 | 0.00 | -3708.22 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 1170.58 | 0.00 | 69.96 | 1650.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 17-OCT-11:45 | 0.00 | -4725.25 | 0.00 | 0.00 | 40.61 | 28.81 | 406.15 | 2048.19 | 0.00 | 69.33 | 2132.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 16-OCT-10:00 | 0.00 | -3137.03 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1129.16 | 0.00 | 207.67 | 1324.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 18-JUL-17:30 | 0.00 | -2413.78 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 335.88 | 0.00 | 0.00 | 1163.69 | 0.00 | 0.00 | 0.00 | -10.67 | 0.00 |
M N2 APARTMENT | 18-JUL-17:30 | 0.00 | -2402.19 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 335.96 | 0.00 | 0.00 | 1152.02 | 0.00 | 0.00 | 0.00 | -10.67 | 0.00 |
M S1 APARTMENT | 31-OCT-14:15 | 0.00 | -4052.72 | 0.00 | 0.00 | 40.62 | 50.41 | 400.26 | 1478.45 | 0.00 | 34.70 | 2048.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 31-OCT-14:00 | 0.00 | -4043.07 | 0.00 | 0.00 | 40.52 | 28.81 | 382.60 | 1577.58 | 0.00 | 49.53 | 1964.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 16-OCT-13:30 | 0.00 | -3289.92 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2369.26 | 0.00 | 162.24 | 306.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 29-SEP-15:30 | 0.00 | -2455.77 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1465.23 | 0.00 | 128.19 | 241.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 15-OCT-12:30 | 0.00 | -3037.07 | 0.00 | 0.00 | 40.73 | 28.81 | 388.49 | 2021.13 | 0.00 | 158.81 | 399.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 29-SEP-13:00 | 0.00 | -2064.44 | 0.00 | 0.00 | 40.75 | 28.81 | 388.49 | 762.73 | 0.00 | 182.08 | 661.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 29-SEP-15:15 | 0.00 | -1588.96 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 307.07 | 0.00 | 84.52 | 576.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-SEP-14:15 | 0.00 | -1583.60 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 385.93 | 0.00 | 107.97 | 598.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 16-OCT-14:45 | 0.00 | -2530.73 | 0.00 | 0.00 | 40.03 | 50.41 | 400.26 | 1068.38 | 0.00 | 53.94 | 917.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 16-OCT-14:45 | 0.00 | -2535.63 | 0.00 | 0.00 | 40.00 | 50.41 | 400.26 | 1068.09 | 0.00 | 53.88 | 922.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 29-SEP-15:15 | 0.00 | -55203.74 | 0.00 | 0.00 | 1123.47 | 4322.48 | 11242.16 | 22121.35 | 0.00 | 2361.27 | 14033.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 08-JAN-06:45 | 535.70 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -603.67 | 0.00 | -132.00 | -408.39 |
G NW APARTMENT | 23-DEC-06:10 | 464.56 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -491.86 | 0.00 | -86.25 | -494.81 |
OFFICE | 30-MAR-06:01 | 2158.75 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 271.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -140.54 | -2864.06 |
G NE APARTMENT | 08-JAN-07:14 | 763.99 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -49.70 | 0.00 | -126.95 | -1224.79 |
G N1 APARTMENT | 08-JAN-03:30 | 557.87 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -313.61 | 0.00 | -49.44 | -622.57 |
G N2 APARTMENT | 08-JAN-04:30 | 601.58 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -323.75 | 0.00 | -65.01 | -669.38 |
G S1 APARTMENT | 29-MAR-24:00 | 524.14 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -301.53 | 0.00 | -78.10 | -613.47 |
G S2 APARTMENT | 29-MAR-24:00 | 517.22 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -301.65 | 0.00 | -78.10 | -606.43 |
M SW APARTMENT | 12-FEB-07:00 | 54.87 | 0.00 | 0.00 | 0.00 | 163.05 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 1.78 | 0.00 | -191.49 | 0.00 | -446.89 | 0.00 |
M NW APARTMENT | 18-DEC-08:38 | 157.15 | 0.00 | 0.00 | 0.00 | 63.99 | 43.21 | 388.49 | 43.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -384.20 | -312.19 |
M SE APARTMENT | 11-FEB-16:00 | 18.35 | 0.00 | 0.00 | 0.00 | 40.75 | 50.41 | 400.26 | 0.00 | 0.00 | 0.00 | 181.02 | 0.00 | -191.59 | 0.00 | -499.21 | 0.00 |
M NE APARTMENT | 18-DEC-08:04 | 24.75 | 0.00 | 0.00 | 0.00 | 63.59 | 43.21 | 388.49 | 628.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -445.19 | -703.34 |
M N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 31-DEC-07:01 | 695.46 | 0.00 | 0.00 | 0.00 | 162.00 | 93.63 | 382.60 | 5.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -202.24 | -1136.72 |
T NW APARTMENT | 11-MAR-06:01 | 941.24 | 0.00 | 0.00 | 0.00 | 162.17 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -386.20 | 0.00 | -213.32 | -980.11 |
T SE APARTMENT | 30-MAR-04:00 | 707.47 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -511.65 | 0.00 | -305.91 | -346.47 |
T NE APARTMENT | 30-MAR-03:00 | 767.96 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -508.42 | 0.00 | -313.42 | -373.87 |
T N1 APARTMENT | 05-JAN-07:14 | 506.81 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -250.94 | 0.00 | -109.89 | -783.43 |
T N2 APARTMENT | 05-JAN-07:14 | 509.73 | 0.00 | 0.00 | 0.00 | 161.22 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -250.89 | 0.00 | -109.89 | -786.40 |
T S1 APARTMENT | 09-JAN-06:25 | 448.40 | 0.00 | 0.00 | 0.00 | 189.67 | 100.83 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -354.74 | 0.00 | -143.85 | -558.16 |
T S2 APARTMENT | 29-MAR-06:01 | 1161.03 | 0.00 | 0.00 | 0.00 | 162.80 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -198.47 | 0.00 | -123.36 | -1478.23 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 30-MAR-03:00 | -1217.04 | 0.00 | 0.00 | 0.00 | 4288.54 | 2334.74 | 5313.65 | 0.00 | 0.00 | 0.00 | 4552.81 | 0.00 | -10493.17 | 0.00 | -4779.53 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Sec1.1A-General InformationData | |
Weather File | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 20.25 |
Number of hours cooling loads not met | 19.00 |
Number of hours not met | 39.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 8572.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 6.78 | 14058.44 | 0.00 | 0.00 |
Space Cooling | 119.06 | 13788.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 181.59 | 5758.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 366.52 | 22172.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 26456.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1383.03 | 6.78 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1383.03 |
Natural Gas | 0.00 | 6.78 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 1389.81 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 37.98 |
Fans-Interior | 57.93 |
Service Water Heating | 116.93 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.58 |
Subtotal | 441.21 |
Natural Gas [MJ/m2] | |
Space Heating | 2.16 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 2.16 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 11.87 |
Space Heating | 0.49 |
Space Cooling | 8.57 |
Fans-Interior | 13.07 |
Service Water Heating | 26.37 |
Receptacle Equipment | 36.80 |
Miscellaneous | 2.84 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.148386 |
G NW APARTMENT DIRECT AIR | 0.136497 |
OFFICE DIRECT AIR | 0.427520 |
G NE APARTMENT DIRECT AIR | 0.104479 |
G N1 APARTMENT DIRECT AIR | 0.081979 |
G N2 APARTMENT DIRECT AIR | 0.081262 |
G S1 APARTMENT DIRECT AIR | 0.095082 |
G S2 APARTMENT DIRECT AIR | 0.098130 |
M SW APARTMENT DIRECT AIR | 0.395636 |
M NW APARTMENT DIRECT AIR | 0.364314 |
M SE APARTMENT DIRECT AIR | 0.346289 |
M NE APARTMENT DIRECT AIR | 0.293323 |
M N1 APARTMENT DIRECT AIR | 0.231661 |
M N2 APARTMENT DIRECT AIR | 0.230366 |
M S1 APARTMENT DIRECT AIR | 0.267597 |
M S2 APARTMENT DIRECT AIR | 0.268643 |
T SW APARTMENT DIRECT AIR | 0.254382 |
T NW APARTMENT DIRECT AIR | 0.231235 |
T SE APARTMENT DIRECT AIR | 0.229127 |
T NE APARTMENT DIRECT AIR | 0.183595 |
T N1 APARTMENT DIRECT AIR | 0.145940 |
T N2 APARTMENT DIRECT AIR | 0.146082 |
T S1 APARTMENT DIRECT AIR | 0.189237 |
T S2 APARTMENT DIRECT AIR | 0.189885 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.148386 |
SPLIT GNW MAIN BRANCH | 0.136497 |
SPLIT OFFICE MAIN BRANCH | 0.427520 |
SPLIT GNE MAIN BRANCH | 0.104479 |
SPLIT GN1 MAIN BRANCH | 0.081979 |
SPLIT GN2 MAIN BRANCH | 0.081262 |
SPLIT GS1 MAIN BRANCH | 0.095082 |
SPLIT GS2 MAIN BRANCH | 0.098130 |
SPLIT MSW MAIN BRANCH | 0.395636 |
SPLIT MNW MAIN BRANCH | 0.364314 |
SPLIT MSE MAIN BRANCH | 0.346289 |
SPLIT MNE MAIN BRANCH | 0.293323 |
SPLIT MN1 MAIN BRANCH | 0.231661 |
SPLIT MN2 MAIN BRANCH | 0.230366 |
SPLIT MS1 MAIN BRANCH | 0.267597 |
SPLIT MS2 MAIN BRANCH | 0.268643 |
SPLIT TSW MAIN BRANCH | 0.254382 |
SPLIT TNW MAIN BRANCH | 0.231235 |
SPLIT TSE MAIN BRANCH | 0.229127 |
SPLIT TNE MAIN BRANCH | 0.183595 |
SPLIT TN1 MAIN BRANCH | 0.145940 |
SPLIT TN2 MAIN BRANCH | 0.146082 |
SPLIT TS1 MAIN BRANCH | 0.189237 |
SPLIT TS2 MAIN BRANCH | 0.189885 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.148386 |
SPLIT GNW | 0.136497 |
SPLIT OFFICE | 0.427520 |
SPLIT GNE | 0.104479 |
SPLIT GN1 | 0.081979 |
SPLIT GN2 | 0.081262 |
SPLIT GS1 | 0.095082 |
SPLIT GS2 | 0.098130 |
SPLIT MSW | 0.395636 |
SPLIT MNW | 0.364314 |
SPLIT MSE | 0.346289 |
SPLIT MNE | 0.293323 |
SPLIT MN1 | 0.231661 |
SPLIT MN2 | 0.230366 |
SPLIT MS1 | 0.267597 |
SPLIT MS2 | 0.268643 |
SPLIT TSW | 0.254382 |
SPLIT TNW | 0.231235 |
SPLIT TSE | 0.229127 |
SPLIT TNE | 0.183595 |
SPLIT TN1 | 0.145940 |
SPLIT TN2 | 0.146082 |
SPLIT TS1 | 0.189237 |
SPLIT TS2 | 0.189885 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.148386 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.136497 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.427520 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.104479 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.081979 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.081262 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.095082 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.098130 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.395636 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.364314 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.346289 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.293323 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.231661 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.230366 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.267597 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.268643 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.254382 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.231235 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.229127 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.183595 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.145940 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.146082 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.189237 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.189885 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.148386 | 2468.85 | 0.796789 |
SPLIT GNW COOLING COIL | 0.136497 | 2259.51 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.427520 | 7076.98 | 0.798655 |
SPLIT GNE COOLING COIL | 0.104479 | 1729.50 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.081979 | 1389.20 | 0.790146 |
SPLIT GN2 COOLING COIL | 0.081262 | 1378.14 | 0.789860 |
SPLIT GS1 COOLING COIL | 0.095082 | 1670.39 | 0.777429 |
SPLIT GS2 COOLING COIL | 0.098130 | 1717.20 | 0.778786 |
SPLIT MSW COOLING COIL | 0.395636 | 6549.17 | 0.798655 |
SPLIT MNW COOLING COIL | 0.364314 | 6030.69 | 0.798655 |
SPLIT MSE COOLING COIL | 0.346289 | 5745.13 | 0.797836 |
SPLIT MNE COOLING COIL | 0.293323 | 4855.53 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.231661 | 3837.87 | 0.798362 |
SPLIT MN2 COOLING COIL | 0.230366 | 3818.02 | 0.798209 |
SPLIT MS1 COOLING COIL | 0.267597 | 4538.16 | 0.789867 |
SPLIT MS2 COOLING COIL | 0.268643 | 4554.27 | 0.789994 |
SPLIT TSW COOLING COIL | 0.254382 | 4210.92 | 0.798655 |
SPLIT TNW COOLING COIL | 0.231235 | 3827.76 | 0.798655 |
SPLIT TSE COOLING COIL | 0.229127 | 3792.87 | 0.798655 |
SPLIT TNE COOLING COIL | 0.183595 | 3051.75 | 0.797138 |
SPLIT TN1 COOLING COIL | 0.145940 | 2472.37 | 0.790248 |
SPLIT TN2 COOLING COIL | 0.146082 | 2474.52 | 0.790283 |
SPLIT TS1 COOLING COIL | 0.189237 | 3136.98 | 0.798135 |
SPLIT TS2 COOLING COIL | 0.189885 | 3143.28 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.148386 | 0.148386 | 0.148386 | 0.148386 | 1475.74 | 2468.85 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.136497 | 0.136497 | 0.136497 | 0.136497 | 1423.87 | 2259.51 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.427520 | 0.427520 | 0.427520 | 0.427520 | 2489.99 | 7076.98 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.104479 | 0.104479 | 0.104479 | 0.104479 | 1423.87 | 1729.50 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.081979 | 0.081979 | 0.081979 | 0.081979 | 1423.87 | 1389.20 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.081262 | 0.081262 | 0.081262 | 0.081262 | 1423.87 | 1378.14 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.095082 | 0.095082 | 0.095082 | 0.095082 | 1423.87 | 1670.39 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.098130 | 0.098130 | 0.098130 | 0.098130 | 1423.87 | 1717.20 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.395636 | 0.395636 | 0.395636 | 0.395636 | 2847.74 | 6549.17 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.364314 | 0.364314 | 0.364314 | 0.364314 | 2847.74 | 6030.69 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.346289 | 0.346289 | 0.346289 | 0.346289 | 2847.74 | 5745.13 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.293323 | 0.293323 | 0.293323 | 0.293323 | 2847.74 | 4855.53 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.231661 | 0.231661 | 0.231661 | 0.231661 | 2847.74 | 3837.87 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.230366 | 0.230366 | 0.230366 | 0.230366 | 2847.74 | 3818.02 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.267597 | 0.267597 | 0.267597 | 0.267597 | 2847.74 | 4538.16 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.268643 | 0.268643 | 0.268643 | 0.268643 | 2847.74 | 4554.27 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.254382 | 0.254382 | 0.254382 | 0.254382 | 1823.72 | 4210.92 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.231235 | 0.231235 | 0.231235 | 0.231235 | 1821.15 | 3827.76 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.229127 | 0.229127 | 0.229127 | 0.229127 | 1827.14 | 3792.87 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.183595 | 0.183595 | 0.183595 | 0.183595 | 1824.58 | 3051.75 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.145940 | 0.145940 | 0.145940 | 0.145940 | 1423.87 | 2472.37 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.146082 | 0.146082 | 0.146082 | 0.146082 | 1423.87 | 2474.52 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.189237 | 0.189237 | 0.189237 | 0.189237 | 1423.87 | 3136.98 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.189885 | 0.189885 | 0.189885 | 0.189885 | 1423.87 | 3143.28 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.148386 |
SPLIT GNW SUPPLY FAN | 0.136497 |
SPLIT OFFICE SUPPLY FAN | 0.427520 |
SPLIT GNE SUPPLY FAN | 0.104479 |
SPLIT GN1 SUPPLY FAN | 0.081979 |
SPLIT GN2 SUPPLY FAN | 0.081262 |
SPLIT GS1 SUPPLY FAN | 0.095082 |
SPLIT GS2 SUPPLY FAN | 0.098130 |
SPLIT MSW SUPPLY FAN | 0.395636 |
SPLIT MNW SUPPLY FAN | 0.364314 |
SPLIT MSE SUPPLY FAN | 0.346289 |
SPLIT MNE SUPPLY FAN | 0.293323 |
SPLIT MN1 SUPPLY FAN | 0.231661 |
SPLIT MN2 SUPPLY FAN | 0.230366 |
SPLIT MS1 SUPPLY FAN | 0.267597 |
SPLIT MS2 SUPPLY FAN | 0.268643 |
SPLIT TSW SUPPLY FAN | 0.254382 |
SPLIT TNW SUPPLY FAN | 0.231235 |
SPLIT TSE SUPPLY FAN | 0.229127 |
SPLIT TNE SUPPLY FAN | 0.183595 |
SPLIT TN1 SUPPLY FAN | 0.145940 |
SPLIT TN2 SUPPLY FAN | 0.146082 |
SPLIT TS1 SUPPLY FAN | 0.189237 |
SPLIT TS2 SUPPLY FAN | 0.189885 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 1475.74 |
SPLIT GNW HEATING COIL | 1423.87 |
SPLIT OFFICE HEATING COIL | 2489.99 |
SPLIT GNE HEATING COIL | 1423.87 |
SPLIT GN1 HEATING COIL | 1423.87 |
SPLIT GN2 HEATING COIL | 1423.87 |
SPLIT GS1 HEATING COIL | 1423.87 |
SPLIT GS2 HEATING COIL | 1423.87 |
SPLIT MSW HEATING COIL | 2847.74 |
SPLIT MNW HEATING COIL | 2847.74 |
SPLIT MSE HEATING COIL | 2847.74 |
SPLIT MNE HEATING COIL | 2847.74 |
SPLIT MN1 HEATING COIL | 2847.74 |
SPLIT MN2 HEATING COIL | 2847.74 |
SPLIT MS1 HEATING COIL | 2847.74 |
SPLIT MS2 HEATING COIL | 2847.74 |
SPLIT TSW HEATING COIL | 1823.72 |
SPLIT TNW HEATING COIL | 1821.15 |
SPLIT TSE HEATING COIL | 1827.14 |
SPLIT TNE HEATING COIL | 1824.58 |
SPLIT TN1 HEATING COIL | 1423.87 |
SPLIT TN2 HEATING COIL | 1423.87 |
SPLIT TS1 HEATING COIL | 1423.87 |
SPLIT TS2 HEATING COIL | 1423.87 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:31
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.17 | 13.22 |
February | 22.95 | 13.28 |
March | 22.81 | 12.64 |
April | 23.41 | 15.30 |
May | 23.32 | 15.56 |
June | 24.27 | 17.67 |
July | 24.39 | 19.43 |
August | 24.39 | 19.66 |
September | 24.37 | 18.47 |
October | 24.00 | 18.77 |
November | 23.40 | 14.32 |
December | 23.23 | 13.59 |
Annual Sum or Average | 23.65 | 16.01 |
Minimum of Months | 22.81 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.40 | 13.22 |
February | 22.33 | 13.28 |
March | 22.39 | 12.64 |
April | 23.09 | 15.30 |
May | 23.25 | 15.56 |
June | 24.27 | 17.67 |
July | 24.39 | 19.43 |
August | 24.39 | 19.66 |
September | 24.34 | 18.47 |
October | 23.77 | 18.77 |
November | 22.65 | 14.32 |
December | 22.47 | 13.59 |
Annual Sum or Average | 23.32 | 16.01 |
Minimum of Months | 22.33 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.31 | 13.22 |
February | 23.32 | 13.28 |
March | 23.22 | 12.64 |
April | 23.63 | 15.30 |
May | 23.65 | 15.56 |
June | 23.90 | 17.67 |
July | 23.90 | 19.43 |
August | 23.90 | 19.66 |
September | 23.90 | 18.47 |
October | 23.85 | 18.77 |
November | 23.57 | 14.32 |
December | 23.37 | 13.59 |
Annual Sum or Average | 23.63 | 16.01 |
Minimum of Months | 23.22 | 12.64 |
Maximum of Months | 23.90 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.34 | 13.22 |
February | 22.23 | 13.28 |
March | 22.32 | 12.64 |
April | 22.99 | 15.30 |
May | 23.12 | 15.56 |
June | 24.22 | 17.67 |
July | 24.38 | 19.43 |
August | 24.38 | 19.66 |
September | 24.31 | 18.47 |
October | 23.69 | 18.77 |
November | 22.54 | 14.32 |
December | 22.38 | 13.59 |
Annual Sum or Average | 23.25 | 16.01 |
Minimum of Months | 22.23 | 12.64 |
Maximum of Months | 24.38 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.28 | 13.22 |
February | 22.19 | 13.28 |
March | 22.22 | 12.64 |
April | 22.77 | 15.30 |
May | 22.94 | 15.56 |
June | 24.22 | 17.67 |
July | 24.38 | 19.43 |
August | 24.38 | 19.66 |
September | 24.32 | 18.47 |
October | 23.64 | 18.77 |
November | 22.49 | 14.32 |
December | 22.34 | 13.59 |
Annual Sum or Average | 23.19 | 16.01 |
Minimum of Months | 22.19 | 12.64 |
Maximum of Months | 24.38 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.28 | 13.22 |
February | 22.19 | 13.28 |
March | 22.22 | 12.64 |
April | 22.77 | 15.30 |
May | 22.93 | 15.56 |
June | 24.22 | 17.67 |
July | 24.38 | 19.43 |
August | 24.38 | 19.66 |
September | 24.32 | 18.47 |
October | 23.63 | 18.77 |
November | 22.48 | 14.32 |
December | 22.34 | 13.59 |
Annual Sum or Average | 23.18 | 16.01 |
Minimum of Months | 22.19 | 12.64 |
Maximum of Months | 24.38 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.22 | 13.22 |
February | 22.96 | 13.28 |
March | 22.76 | 12.64 |
April | 23.26 | 15.30 |
May | 23.08 | 15.56 |
June | 24.24 | 17.67 |
July | 24.38 | 19.43 |
August | 24.39 | 19.66 |
September | 24.37 | 18.47 |
October | 24.00 | 18.77 |
November | 23.43 | 14.32 |
December | 23.30 | 13.59 |
Annual Sum or Average | 23.62 | 16.01 |
Minimum of Months | 22.76 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.21 | 13.22 |
February | 22.97 | 13.28 |
March | 22.77 | 12.64 |
April | 23.26 | 15.30 |
May | 23.09 | 15.56 |
June | 24.23 | 17.67 |
July | 24.38 | 19.43 |
August | 24.39 | 19.66 |
September | 24.36 | 18.47 |
October | 23.99 | 18.77 |
November | 23.43 | 14.32 |
December | 23.30 | 13.59 |
Annual Sum or Average | 23.62 | 16.01 |
Minimum of Months | 22.77 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 13.22 |
February | 24.34 | 13.28 |
March | 24.26 | 12.64 |
April | 24.38 | 15.30 |
May | 24.39 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.40 | 18.77 |
November | 24.37 | 14.32 |
December | 24.33 | 13.59 |
Annual Sum or Average | 24.36 | 16.01 |
Minimum of Months | 24.26 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.07 | 13.22 |
February | 24.22 | 13.28 |
March | 24.16 | 12.64 |
April | 24.37 | 15.30 |
May | 24.39 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.39 | 18.77 |
November | 24.28 | 14.32 |
December | 24.15 | 13.59 |
Annual Sum or Average | 24.30 | 16.01 |
Minimum of Months | 24.07 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.30 | 13.22 |
February | 24.32 | 13.28 |
March | 24.24 | 12.64 |
April | 24.38 | 15.30 |
May | 24.38 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.40 | 18.77 |
November | 24.36 | 14.32 |
December | 24.32 | 13.59 |
Annual Sum or Average | 24.36 | 16.01 |
Minimum of Months | 24.24 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.06 | 13.22 |
February | 24.18 | 13.28 |
March | 24.12 | 12.64 |
April | 24.36 | 15.30 |
May | 24.38 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.38 | 18.77 |
November | 24.26 | 14.32 |
December | 24.12 | 13.59 |
Annual Sum or Average | 24.29 | 16.01 |
Minimum of Months | 24.06 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.18 | 13.22 |
February | 24.31 | 13.28 |
March | 24.25 | 12.64 |
April | 24.38 | 15.30 |
May | 24.39 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.40 | 18.77 |
November | 24.34 | 14.32 |
December | 24.25 | 13.59 |
Annual Sum or Average | 24.34 | 16.01 |
Minimum of Months | 24.18 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.18 | 13.22 |
February | 24.30 | 13.28 |
March | 24.25 | 12.64 |
April | 24.38 | 15.30 |
May | 24.39 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.40 | 18.77 |
November | 24.33 | 14.32 |
December | 24.24 | 13.59 |
Annual Sum or Average | 24.34 | 16.01 |
Minimum of Months | 24.18 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.36 | 13.22 |
February | 24.39 | 13.28 |
March | 24.33 | 12.64 |
April | 24.39 | 15.30 |
May | 24.40 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.41 | 18.77 |
November | 24.40 | 14.32 |
December | 24.38 | 13.59 |
Annual Sum or Average | 24.39 | 16.01 |
Minimum of Months | 24.33 | 12.64 |
Maximum of Months | 24.41 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.36 | 13.22 |
February | 24.39 | 13.28 |
March | 24.33 | 12.64 |
April | 24.39 | 15.30 |
May | 24.39 | 15.56 |
June | 24.40 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.40 | 18.47 |
October | 24.41 | 18.77 |
November | 24.40 | 14.32 |
December | 24.38 | 13.59 |
Annual Sum or Average | 24.39 | 16.01 |
Minimum of Months | 24.33 | 12.64 |
Maximum of Months | 24.41 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.71 | 13.22 |
February | 23.65 | 13.28 |
March | 23.60 | 12.64 |
April | 24.13 | 15.30 |
May | 24.15 | 15.56 |
June | 24.36 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.37 | 18.47 |
October | 24.26 | 18.77 |
November | 23.94 | 14.32 |
December | 23.72 | 13.59 |
Annual Sum or Average | 24.06 | 16.01 |
Minimum of Months | 23.60 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.23 | 13.22 |
February | 23.28 | 13.28 |
March | 23.37 | 12.64 |
April | 24.04 | 15.30 |
May | 24.12 | 15.56 |
June | 24.36 | 17.67 |
July | 24.40 | 19.43 |
August | 24.39 | 19.66 |
September | 24.35 | 18.47 |
October | 24.16 | 18.77 |
November | 23.58 | 14.32 |
December | 23.25 | 13.59 |
Annual Sum or Average | 23.88 | 16.01 |
Minimum of Months | 23.23 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.71 | 13.22 |
February | 23.60 | 13.28 |
March | 23.58 | 12.64 |
April | 24.11 | 15.30 |
May | 24.13 | 15.56 |
June | 24.35 | 17.67 |
July | 24.39 | 19.43 |
August | 24.40 | 19.66 |
September | 24.36 | 18.47 |
October | 24.25 | 18.77 |
November | 23.92 | 14.32 |
December | 23.71 | 13.59 |
Annual Sum or Average | 24.05 | 16.01 |
Minimum of Months | 23.58 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.18 | 13.22 |
February | 23.19 | 13.28 |
March | 23.30 | 12.64 |
April | 24.00 | 15.30 |
May | 24.07 | 15.56 |
June | 24.33 | 17.67 |
July | 24.39 | 19.43 |
August | 24.39 | 19.66 |
September | 24.32 | 18.47 |
October | 24.14 | 18.77 |
November | 23.51 | 14.32 |
December | 23.17 | 13.59 |
Annual Sum or Average | 23.84 | 16.01 |
Minimum of Months | 23.17 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.18 | 13.22 |
February | 23.30 | 13.28 |
March | 23.38 | 12.64 |
April | 24.06 | 15.30 |
May | 24.14 | 15.56 |
June | 24.35 | 17.67 |
July | 24.39 | 19.43 |
August | 24.39 | 19.66 |
September | 24.35 | 18.47 |
October | 24.19 | 18.77 |
November | 23.58 | 14.32 |
December | 23.22 | 13.59 |
Annual Sum or Average | 23.88 | 16.01 |
Minimum of Months | 23.18 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.18 | 13.22 |
February | 23.29 | 13.28 |
March | 23.37 | 12.64 |
April | 24.05 | 15.30 |
May | 24.14 | 15.56 |
June | 24.35 | 17.67 |
July | 24.39 | 19.43 |
August | 24.39 | 19.66 |
September | 24.35 | 18.47 |
October | 24.19 | 18.77 |
November | 23.58 | 14.32 |
December | 23.22 | 13.59 |
Annual Sum or Average | 23.88 | 16.01 |
Minimum of Months | 23.18 | 12.64 |
Maximum of Months | 24.39 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 13.22 |
February | 23.82 | 13.28 |
March | 23.73 | 12.64 |
April | 24.19 | 15.30 |
May | 24.20 | 15.56 |
June | 24.37 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.38 | 18.47 |
October | 24.31 | 18.77 |
November | 24.05 | 14.32 |
December | 23.86 | 13.59 |
Annual Sum or Average | 24.13 | 16.01 |
Minimum of Months | 23.73 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 13.22 |
February | 23.81 | 13.28 |
March | 23.73 | 12.64 |
April | 24.19 | 15.30 |
May | 24.20 | 15.56 |
June | 24.37 | 17.67 |
July | 24.40 | 19.43 |
August | 24.40 | 19.66 |
September | 24.38 | 18.47 |
October | 24.31 | 18.77 |
November | 24.05 | 14.32 |
December | 23.86 | 13.59 |
Annual Sum or Average | 24.13 | 16.01 |
Minimum of Months | 23.73 | 12.64 |
Maximum of Months | 24.40 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.66 | 13.22 |
February | 24.72 | 13.28 |
March | 24.75 | 12.64 |
April | 25.68 | 15.30 |
May | 25.76 | 15.56 |
June | 26.24 | 17.67 |
July | 26.49 | 19.43 |
August | 26.48 | 19.66 |
September | 26.24 | 18.47 |
October | 26.04 | 18.77 |
November | 25.09 | 14.32 |
December | 24.69 | 13.59 |
Annual Sum or Average | 25.57 | 16.01 |
Minimum of Months | 24.66 | 12.64 |
Maximum of Months | 26.49 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.82 | 13.22 |
February | 22.76 | 13.28 |
March | 22.65 | 12.64 |
April | 23.40 | 15.30 |
May | 23.49 | 15.56 |
June | 25.09 | 17.67 |
July | 25.63 | 19.43 |
August | 25.70 | 19.66 |
September | 25.44 | 18.47 |
October | 24.46 | 18.77 |
November | 23.23 | 14.32 |
December | 22.96 | 13.59 |
Annual Sum or Average | 23.98 | 16.01 |
Minimum of Months | 22.65 | 12.64 |
Maximum of Months | 25.70 | 19.66 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.32 | 13.22 |
February | 26.38 | 13.28 |
March | 26.30 | 12.64 |
April | 26.59 | 15.30 |
May | 26.60 | 15.56 |
June | 26.71 | 17.67 |
July | 26.82 | 19.43 |
August | 26.83 | 19.66 |
September | 26.76 | 18.47 |
October | 26.75 | 18.77 |
November | 26.51 | 14.32 |
December | 26.39 | 13.59 |
Annual Sum or Average | 26.58 | 16.01 |
Minimum of Months | 26.30 | 12.64 |
Maximum of Months | 26.83 | 19.66 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.114987E+12 | 70888.106 | 18-JAN-18:15 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 5707.397 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21885.111 | 0.000 | 0.000 | 0.000 |
February | 0.102760E+12 | 71728.388 | 01-FEB-18:15 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 4909.955 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23522.834 | 0.000 | 0.000 | 0.000 |
March | 0.113187E+12 | 71967.214 | 21-MAR-17:00 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 5017.906 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23653.710 | 0.000 | 0.000 | 0.000 |
April | 0.112095E+12 | 71528.583 | 23-APR-17:00 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 5683.851 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25057.463 | 0.000 | 0.000 | 0.000 |
May | 0.114087E+12 | 69600.701 | 03-MAY-17:45 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 6233.202 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22580.230 | 0.000 | 0.000 | 0.000 |
June | 0.114294E+12 | 72518.816 | 29-JUN-17:45 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 11923.317 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19808.230 | 0.000 | 0.000 | 0.000 |
July | 0.123346E+12 | 74625.922 | 18-JUL-17:30 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 14012.989 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19825.664 | 0.000 | 0.000 | 0.000 |
August | 0.124529E+12 | 73782.725 | 15-AUG-17:15 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 12795.433 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 20200.024 | 0.000 | 0.000 | 0.000 |
September | 0.117040E+12 | 76747.587 | 29-SEP-17:30 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 13787.998 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22172.320 | 0.000 | 0.000 | 0.000 |
October | 0.120650E+12 | 76615.716 | 14-OCT-17:30 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 11240.884 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22079.233 | 0.000 | 0.000 | 0.000 |
November | 0.110998E+12 | 72426.018 | 08-NOV-18:15 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 4772.219 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24358.201 | 0.000 | 0.000 | 0.000 |
December | 0.115057E+12 | 71121.295 | 19-DEC-18:30 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 5168.226 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22657.470 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.138303E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.102760E+12 | 69600.701 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 4772.219 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19808.230 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.124529E+12 | 76747.587 | 8572.775 | 26456.413 | 5758.081 | 0.000 | 14012.989 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25057.463 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:31
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.213729E+10 | 11888.640 | 03-JAN-03:00 | 11888.640 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 11888.640 |
February | 0.726243E+09 | 5062.655 | 05-FEB-05:00 | 5062.655 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5062.655 |
March | 0.188721E+10 | 14058.436 | 30-MAR-02:00 | 14058.436 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14058.436 |
April | 0.109457E+09 | 5097.723 | 01-APR-05:00 | 5097.723 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5097.723 |
May | 0.457217E+08 | 1427.002 | 14-MAY-03:00 | 1427.002 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1427.002 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 264113.101 | 76.200 | 30-OCT-02:00 | 76.200 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 76.200 |
November | 0.402300E+09 | 5126.012 | 24-NOV-03:00 | 5126.012 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5126.012 |
December | 0.146699E+10 | 9612.800 | 13-DEC-04:30 | 9612.800 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9612.800 |
Annual Sum or Average | 0.677547E+10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.213729E+10 | 14058.436 | 14058.436 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14058.436 |