Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Simulation Timestamp: 2018-10-19 09:20:32
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2462.93 | 785.72 | 872.15 |
Net Site Energy | 2462.93 | 785.72 | 872.15 |
Total Source Energy | 5754.22 | 1835.70 | 2037.63 |
Net Source Energy | 5754.22 | 1835.70 | 2037.63 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 982.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 49.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 165.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 214.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 500.66 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1480.75 | 982.18 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 982.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 49.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 138.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 26.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 39.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 511.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 214.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 500.66 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 72.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 270.97 | 347.80 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 181.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 524.35 | 347.80 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 244.12 | 313.33 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 163.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 472.39 | 313.33 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1480.75 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1480.75 | 100.00 |
Total On-Site and Utility Electric Sources | 1480.75 | 100.00 |
Total Electricity End Uses | 1480.75 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 27.25 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 4607.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:20 |
RunPeriod | Fairbanks Intl Arpt AK USA TMY3 WMO#=702610 |
Weather File | Fairbanks Intl Arpt AK USA TMY3 WMO#=702610 |
Latitude [deg] | 64.82 |
Longitude [deg] | -147.8 |
Elevation [m] | 133.00 |
Time Zone | -9.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 8.5250 | 208.0991 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 8.5250 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 14.1058 | 39.93 | 11.1646 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 14.7196 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 8.5250 | 52.0248 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-JUL-18:15 | 29-JAN-00:15 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 139689.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 14959.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 9689.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 23563.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6809.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 31184.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 86205.64 | 139689.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 139689.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 14959.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 8059.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1629.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 23563.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6809.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 31184.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1064.68 | 0.00 | 0.00 | 0.00 |
Cooling | 157.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 522.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 123.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1619.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 680.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1585.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4689.54 | 1064.68 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 377.01 | 0.00 | 0.00 | 0.00 |
Cooling | 55.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 43.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 240.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 561.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1660.62 | 377.01 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 377.01 | 0.00 | 0.00 | 0.00 |
Cooling | 55.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 185.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 43.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 573.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 240.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 561.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1660.62 | 377.01 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | -41.90 | 0.00 | -41.90 | Wetbulb [C] | 0.30 | 20.00 |
FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 27.40 | 10.20 | 16.10 | Wetbulb [C] | 3.10 | 180.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.210 | 0.217 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.42_SHGC_0.45 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.493 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.493 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.493 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.493 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.493 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 11.5174 | 176.50 | 2032.80 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 11.5174 | 88.25 | 1016.40 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 8.5250 | 155.32 | 1324.09 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 8.5250 | 77.66 | 662.05 | GeneralLights | LTG_COR_SCH | 137.36 | 168.00 | 137.36 | 0.0000 | N | 17.07 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 11.9479 | 88.25 | 1054.40 | GeneralLights-plugin | LTG_OFF_SCH | 56.36 | 168.00 | 55.36 | 0.0000 | Y | 10.96 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 2.9063 | 176.50 | 512.95 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.4206 | 5958.59 | 44216.13 | 128.63 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2508.33 | AstronomicalClock | - | 83.06 | 83.06 | 39.11 | |
Exterior Lighting Total | 2508.33 | 39.11 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2758.65 | 2203.21 | 555.44 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2227.79 | 1779.24 | 448.55 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6994.56 | 5586.24 | 1408.32 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1539.71 | 1229.70 | 310.01 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1362.11 | 1087.86 | 274.25 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1343.90 | 1073.31 | 270.59 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2078.10 | 1659.69 | 418.41 | 0.80 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2128.78 | 1700.16 | 428.62 | 0.80 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8163.63 | 6519.93 | 1643.70 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6662.00 | 5320.64 | 1341.36 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7753.37 | 6192.27 | 1561.10 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5213.23 | 4163.57 | 1049.66 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4358.95 | 3481.30 | 877.65 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4325.12 | 3454.28 | 870.84 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6376.73 | 5092.81 | 1283.92 | 0.80 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6397.90 | 5109.71 | 1288.18 | 0.80 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5184.17 | 4140.36 | 1043.80 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4043.53 | 3229.39 | 814.14 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4949.24 | 3952.74 | 996.50 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3102.35 | 2477.71 | 624.64 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.85 | 2026.87 | 510.98 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2502.36 | 1998.53 | 503.84 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4309.88 | 3442.11 | 867.77 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4326.19 | 3455.14 | 871.06 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2628.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2122.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6663.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1466.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1297.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1280.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1979.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2028.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7777.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6346.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7386.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4966.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4152.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4120.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6074.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6095.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4938.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3852.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4714.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2955.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2417.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2383.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4105.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4121.4 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 4380.83 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 4322.48 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 7635.65 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 4328.50 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 3561.71 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 3561.83 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 3552.15 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 3692.52 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 7564.91 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 7593.70 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 7580.91 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 7609.73 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 5818.98 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 5819.35 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 5793.87 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 5794.23 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 5899.17 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 5917.55 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 5907.98 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 5926.38 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 5041.35 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 5041.56 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 5021.53 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 5021.73 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 186.67 | 1120.11 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 150.75 | 1120.11 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 473.29 | 1120.11 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.09 | 104.19 | 1120.11 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 92.17 | 1120.11 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.08 | 90.94 | 1120.11 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 140.62 | 1120.11 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 144.05 | 1120.11 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.49 | 552.40 | 1120.11 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 450.79 | 1120.11 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.47 | 524.64 | 1120.11 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 352.76 | 1120.11 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 294.95 | 1120.11 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 292.66 | 1120.11 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 431.49 | 1120.11 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 432.92 | 1120.11 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 350.79 | 1120.11 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 273.61 | 1120.11 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 334.89 | 1120.11 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 209.92 | 1120.11 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 171.73 | 1120.11 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 169.32 | 1120.11 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 291.63 | 1120.11 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 292.74 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.89 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1745.88 | 2095.05 | 0.139 | 0.167 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 26.18 | 0.00698 |
G NW APARTMENT | 1409.88 | 1691.86 | 0.112 | 0.135 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 20:00:00 | 22.30 | 0.00698 |
OFFICE | 4340.33 | 5208.39 | 0.352 | 0.423 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 21.79 | 0.00698 |
G NE APARTMENT | 974.42 | 1169.31 | 0.078 | 0.093 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 23.91 | 0.00698 |
G N1 APARTMENT | 862.02 | 1034.42 | 0.069 | 0.082 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 21:00:00 | 21.38 | 0.00698 |
G N2 APARTMENT | 850.49 | 1020.59 | 0.068 | 0.081 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 21:00:00 | 21.38 | 0.00698 |
G S1 APARTMENT | 1315.17 | 1578.20 | 0.105 | 0.126 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 27.40 | 0.00698 |
G S2 APARTMENT | 1347.24 | 1616.69 | 0.107 | 0.129 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 27.40 | 0.00698 |
M SW APARTMENT | 5166.56 | 6199.88 | 0.411 | 0.493 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 25.72 | 0.00698 |
M NW APARTMENT | 4216.14 | 5059.36 | 0.335 | 0.402 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 20:00:00 | 22.30 | 0.00698 |
M SE APARTMENT | 4906.92 | 5888.31 | 0.390 | 0.468 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 27.40 | 0.00698 |
M NE APARTMENT | 3299.31 | 3959.17 | 0.262 | 0.315 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 24.29 | 0.00698 |
M N1 APARTMENT | 2758.59 | 3310.31 | 0.219 | 0.263 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 21:00:00 | 21.38 | 0.00698 |
M N2 APARTMENT | 2737.18 | 3284.62 | 0.218 | 0.261 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 21:00:00 | 21.38 | 0.00698 |
M S1 APARTMENT | 4035.66 | 4842.79 | 0.321 | 0.385 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 27.40 | 0.00698 |
M S2 APARTMENT | 4049.06 | 4858.87 | 0.322 | 0.386 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 27.40 | 0.00698 |
T SW APARTMENT | 3280.95 | 3937.14 | 0.261 | 0.313 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 26.38 | 0.00698 |
T NW APARTMENT | 2559.05 | 3070.86 | 0.204 | 0.244 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 24.19 | 0.00698 |
T SE APARTMENT | 3132.27 | 3758.72 | 0.249 | 0.299 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 27.40 | 0.00698 |
T NE APARTMENT | 1963.41 | 2356.09 | 0.156 | 0.187 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 25.31 | 0.00698 |
T N1 APARTMENT | 1606.11 | 1927.33 | 0.128 | 0.153 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 20:00:00 | 22.30 | 0.00698 |
T N2 APARTMENT | 1583.68 | 1900.41 | 0.126 | 0.151 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 24.95 | 0.00698 |
T S1 APARTMENT | 2727.61 | 3273.14 | 0.217 | 0.260 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 27.40 | 0.00698 |
T S2 APARTMENT | 2737.94 | 3285.53 | 0.218 | 0.261 | FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 27.40 | 0.00698 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1981.36 | 2377.63 | 0.058 | 0.070 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G NW APARTMENT | 1992.59 | 2391.10 | 0.058 | 0.070 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
OFFICE | 4065.59 | 4878.71 | 0.115 | 0.138 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G NE APARTMENT | 1997.68 | 2397.22 | 0.058 | 0.070 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G N1 APARTMENT | 1349.23 | 1619.08 | 0.039 | 0.047 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G N2 APARTMENT | 1349.34 | 1619.21 | 0.039 | 0.047 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G S1 APARTMENT | 1341.15 | 1609.38 | 0.039 | 0.047 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
G S2 APARTMENT | 1459.86 | 1751.83 | 0.043 | 0.051 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -41.90 | 0.00006 |
M SW APARTMENT | 3071.81 | 3686.17 | 0.090 | 0.108 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M NW APARTMENT | 3096.16 | 3715.39 | 0.091 | 0.109 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M SE APARTMENT | 3085.34 | 3702.41 | 0.090 | 0.108 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M NE APARTMENT | 3109.72 | 3731.66 | 0.091 | 0.109 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M N1 APARTMENT | 1595.36 | 1914.43 | 0.047 | 0.056 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M N2 APARTMENT | 1595.66 | 1914.80 | 0.047 | 0.056 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M S1 APARTMENT | 1574.12 | 1888.95 | 0.046 | 0.055 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
M S2 APARTMENT | 1574.43 | 1889.31 | 0.046 | 0.055 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T SW APARTMENT | 3325.91 | 3991.09 | 0.097 | 0.117 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T NW APARTMENT | 3341.46 | 4009.75 | 0.098 | 0.117 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T SE APARTMENT | 3333.36 | 4000.04 | 0.097 | 0.117 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T NE APARTMENT | 3348.92 | 4018.71 | 0.098 | 0.117 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T N1 APARTMENT | 2600.49 | 3120.59 | 0.076 | 0.091 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T N2 APARTMENT | 2600.67 | 3120.80 | 0.076 | 0.091 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T S1 APARTMENT | 2583.73 | 3100.47 | 0.076 | 0.091 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
T S2 APARTMENT | 2583.90 | 3100.68 | 0.076 | 0.091 | FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -41.90 | 0.00006 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.17 | 0.17 | 0.07 | 0.07 |
SPLIT GNW | 0.13 | 0.13 | 0.07 | 0.07 |
SPLIT OFFICE | 0.42 | 0.42 | 0.14 | 0.14 |
SPLIT GNE | 0.09 | 0.09 | 0.07 | 0.07 |
SPLIT GN1 | 0.08 | 0.08 | 0.05 | 0.05 |
SPLIT GN2 | 0.08 | 0.08 | 0.05 | 0.05 |
SPLIT GS1 | 0.13 | 0.13 | 0.05 | 0.05 |
SPLIT GS2 | 0.13 | 0.13 | 0.05 | 0.05 |
SPLIT MSW | 0.49 | 0.49 | 0.11 | 0.11 |
SPLIT MNW | 0.40 | 0.40 | 0.11 | 0.11 |
SPLIT MSE | 0.47 | 0.47 | 0.11 | 0.11 |
SPLIT MNE | 0.31 | 0.31 | 0.11 | 0.11 |
SPLIT MN1 | 0.26 | 0.26 | 0.06 | 0.06 |
SPLIT MN2 | 0.26 | 0.26 | 0.06 | 0.06 |
SPLIT MS1 | 0.39 | 0.39 | 0.06 | 0.06 |
SPLIT MS2 | 0.39 | 0.39 | 0.06 | 0.06 |
SPLIT TSW | 0.31 | 0.31 | 0.12 | 0.12 |
SPLIT TNW | 0.24 | 0.24 | 0.12 | 0.12 |
SPLIT TSE | 0.30 | 0.30 | 0.12 | 0.12 |
SPLIT TNE | 0.19 | 0.19 | 0.12 | 0.12 |
SPLIT TN1 | 0.15 | 0.15 | 0.09 | 0.09 |
SPLIT TN2 | 0.15 | 0.15 | 0.09 | 0.09 |
SPLIT TS1 | 0.26 | 0.26 | 0.09 | 0.09 |
SPLIT TS2 | 0.26 | 0.26 | 0.09 | 0.09 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 4395.00 | 7136.00 | 3897.50 |
G NW APARTMENT | 4503.00 | 7443.25 | 4259.75 |
OFFICE | 964.50 | 1881.00 | 954.00 |
G NE APARTMENT | 4520.25 | 7366.25 | 4223.25 |
G N1 APARTMENT | 4192.50 | 7656.00 | 4053.00 |
G N2 APARTMENT | 4193.25 | 7649.00 | 4050.75 |
G S1 APARTMENT | 4005.25 | 7122.25 | 3643.25 |
G S2 APARTMENT | 4074.25 | 7160.00 | 3733.25 |
M SW APARTMENT | 4204.25 | 5531.25 | 2833.00 |
M NW APARTMENT | 4498.25 | 6089.75 | 3429.25 |
M SE APARTMENT | 4253.50 | 5472.25 | 2751.25 |
M NE APARTMENT | 4591.25 | 6020.50 | 3358.25 |
M N1 APARTMENT | 3506.00 | 6024.50 | 2575.75 |
M N2 APARTMENT | 3505.25 | 6016.50 | 2566.75 |
M S1 APARTMENT | 3026.00 | 5350.25 | 1730.50 |
M S2 APARTMENT | 3029.00 | 5346.00 | 1727.75 |
T SW APARTMENT | 5317.75 | 6377.75 | 4134.75 |
T NW APARTMENT | 5499.50 | 6755.25 | 4512.25 |
T SE APARTMENT | 5360.50 | 6283.75 | 4079.50 |
T NE APARTMENT | 5566.75 | 6712.00 | 4481.50 |
T N1 APARTMENT | 5212.50 | 6800.50 | 4333.50 |
T N2 APARTMENT | 5213.75 | 6797.75 | 4330.75 |
T S1 APARTMENT | 5020.00 | 6285.00 | 3891.00 |
T S2 APARTMENT | 5022.00 | 6274.50 | 3887.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6352.00 | 7734.50 | 4607.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
G NW APARTMENT | 3.25 | 0.00 | 3.25 | 0.00 |
OFFICE | 29.00 | 0.00 | 0.25 | 0.00 |
G NE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
G N1 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
G N2 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
G S1 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
G S2 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
M SW APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M NW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M SE APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M NE APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M N1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M N2 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M S1 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M S2 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
T SW APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
T NW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T SE APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T NE APARTMENT | 4.00 | 0.00 | 4.00 | 0.00 |
T N1 APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T N2 APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
T S1 APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
T S2 APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 56.00 | 0.00 | 27.25 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.367 | 0.063 | 0.000 | 0.044 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.063 | 0.000 | 0.044 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.520 | 0.061 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.063 | 0.000 | 0.044 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.038 | 0.000 | 0.043 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.038 | 0.000 | 0.043 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.038 | 0.000 | 0.044 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.038 | 0.000 | 0.044 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.091 | 0.000 | 0.051 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.091 | 0.000 | 0.052 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.091 | 0.000 | 0.051 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.091 | 0.000 | 0.052 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.055 | 0.000 | 0.052 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.055 | 0.000 | 0.052 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.055 | 0.000 | 0.051 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.055 | 0.000 | 0.051 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.121 | 0.000 | 0.057 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.121 | 0.000 | 0.057 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.121 | 0.000 | 0.057 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.121 | 0.000 | 0.057 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.073 | 0.000 | 0.057 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.073 | 0.000 | 0.057 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.073 | 0.000 | 0.057 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.073 | 0.000 | 0.057 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.502 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.371 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1425 |
Defaulted Fields | 439 |
Fields with Defaults | 3748 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
Electricity:Building | 676.42 | 10861.97 | 01-JAN-03:15 | 35029.19 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity | 165.00 | 2991.26 | 01-JAN-00:15 | 9689.08 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 138.97 | 2711.50 | 01-JAN-00:15 | 8059.76 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.45 | 508.27 | 01-JAN-00:15 | 2167.25 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.91 | 379.58 | 01-JAN-00:15 | 1622.34 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 29.25 | 476.16 | 01-JAN-03:15 | 1566.15 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 4.83 | 28.81 | 01-JAN-00:15 | 460.92 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.08 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 142.36 | 1349.33 | 01-JAN-00:15 | 8621.71 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 34.14 | 1082.58 | 01-JAN-00:15 | 1082.58 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 17.07 | 541.29 | 01-JAN-00:15 | 541.29 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 26.03 | 279.76 | 01-JAN-00:15 | 1629.32 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 511.42 | 7870.70 | 01-JAN-03:15 | 26522.71 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.53 | 128.69 | 01-JAN-00:15 | 544.92 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 125.29 | 808.04 | 01-JAN-00:15 | 8080.42 | 01-JAN-07:15 |
Electricity:Plant | 500.66 | 0.00 | 01-JAN-00:15 | 33146.68 | 16-JAN-07:30 |
WaterSystems:Electricity | 500.66 | 0.00 | 01-JAN-00:15 | 33146.68 | 16-JAN-07:30 |
Water Heater:WaterSystems:Electricity | 500.66 | 0.00 | 01-JAN-00:15 | 33146.68 | 16-JAN-07:30 |
Fans:Electricity | 214.76 | 6809.89 | 01-JAN-06:15 | 6809.89 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
ElectricityPurchased:Plant | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
Cogeneration:ElectricityPurchased | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
ElectricityNet:Plant | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
Cogeneration:ElectricityNet | 1480.75 | 18256.66 | 26-JUN-02:45 | 86205.64 | 29-JUL-18:15 |
ExteriorLights:Electricity | 39.11 | 0.00 | 01-JAN-11:30 | 2508.33 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 39.11 | 0.00 | 01-JAN-11:30 | 2508.33 | 01-JAN-00:15 |
Electricity:HVAC | 264.57 | 6809.89 | 01-JAN-06:15 | 23924.01 | 29-JUL-16:15 |
General:Fans:Electricity | 214.76 | 6809.89 | 01-JAN-06:15 | 6809.89 | 01-JAN-00:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 49.81 | 0.00 | 01-JAN-00:15 | 17114.12 | 29-JUL-16:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 982.18 | 0.00 | 17-APR-14:00 | 139689.41 | 29-JAN-00:15 |
Gas:HVAC | 982.18 | 0.00 | 17-APR-14:00 | 139689.41 | 29-JAN-00:15 |
Heating:Gas | 982.18 | 0.00 | 17-APR-14:00 | 139689.41 | 29-JAN-00:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1606.53 | 3768.17 | 01-OCT-17:00 | 183654.67 | 29-JAN-00:15 |
EnergyTransfer:Building | 622.09 | 3697.45 | 01-OCT-17:00 | 71903.14 | 29-JAN-00:15 |
EnergyTransfer:Zone:G SW APARTMENT | 17.19 | 0.04 | 22-MAY-13:00 | 2264.26 | 29-JAN-00:15 |
Heating:EnergyTransfer | 332.59 | 0.00 | 18-MAR-16:15 | 71903.14 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 12.20 | 0.00 | 09-FEB-11:45 | 2264.26 | 29-JAN-00:15 |
Cooling:EnergyTransfer | 289.50 | 0.00 | 02-JAN-07:30 | 56019.44 | 11-JUL-17:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 4.99 | 0.00 | 01-JAN-00:15 | 1692.85 | 11-AUG-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 17.81 | 0.06 | 25-MAY-22:15 | 2344.94 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 14.33 | 0.00 | 18-MAR-16:15 | 2344.94 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 3.48 | 0.00 | 01-JAN-00:15 | 1372.58 | 11-JUL-17:45 |
EnergyTransfer:Zone:OFFICE | 23.65 | 0.46 | 21-FEB-11:00 | 4283.07 | 29-JAN-07:30 |
Heating:EnergyTransfer:Zone:OFFICE | 1.69 | 0.00 | 01-JAN-00:15 | 4283.07 | 29-JAN-07:30 |
Cooling:EnergyTransfer:Zone:OFFICE | 21.96 | 0.00 | 02-JAN-07:30 | 3249.12 | 10-AUG-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 18.09 | 0.07 | 30-MAY-17:45 | 2356.45 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 14.04 | 0.00 | 18-MAR-16:15 | 2356.45 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.05 | 0.00 | 01-JAN-00:15 | 1009.87 | 11-JUL-17:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 12.04 | 0.19 | 29-APR-07:45 | 1456.40 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 8.21 | 0.00 | 07-FEB-20:45 | 1456.40 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 3.83 | 0.00 | 01-JAN-00:15 | 837.97 | 11-JUL-19:00 |
EnergyTransfer:Zone:G N2 APARTMENT | 12.05 | 0.18 | 10-MAY-02:30 | 1456.55 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 8.20 | 0.00 | 07-FEB-20:45 | 1456.55 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 3.86 | 0.00 | 01-JAN-00:15 | 831.78 | 11-JUL-19:00 |
EnergyTransfer:Zone:G S1 APARTMENT | 11.75 | 0.27 | 03-MAY-01:30 | 1379.58 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 6.43 | 0.00 | 23-JAN-12:45 | 1379.58 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 5.32 | 0.00 | 01-JAN-00:15 | 1264.43 | 11-AUG-15:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 12.96 | 0.02 | 29-MAR-19:30 | 1537.70 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 7.79 | 0.00 | 23-JAN-13:30 | 1537.70 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 5.17 | 0.00 | 01-JAN-00:15 | 1246.07 | 11-AUG-15:15 |
EnergyTransfer:Zone:M SW APARTMENT | 39.11 | 0.11 | 03-APR-09:30 | 5092.03 | 11-AUG-16:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 14.65 | 0.00 | 21-JAN-20:30 | 4728.38 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 24.45 | 0.00 | 01-JAN-00:15 | 5092.03 | 11-AUG-16:15 |
EnergyTransfer:Zone:M NW APARTMENT | 35.63 | 0.88 | 12-OCT-20:00 | 4993.43 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 19.14 | 0.00 | 21-JAN-20:45 | 4993.43 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 16.49 | 0.00 | 01-JAN-00:15 | 4160.28 | 11-JUL-18:15 |
EnergyTransfer:Zone:M SE APARTMENT | 40.99 | 0.23 | 07-APR-06:00 | 4884.90 | 22-JUL-11:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 14.33 | 0.00 | 21-JAN-20:30 | 4752.64 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 26.66 | 0.00 | 01-JAN-00:15 | 4884.90 | 22-JUL-11:30 |
EnergyTransfer:Zone:M NE APARTMENT | 37.09 | 0.07 | 09-FEB-16:00 | 5018.38 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 18.54 | 0.00 | 21-JAN-20:45 | 5018.38 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 18.54 | 0.00 | 01-JAN-00:15 | 3402.76 | 11-JUL-17:15 |
EnergyTransfer:Zone:M N1 APARTMENT | 23.83 | 0.10 | 28-FEB-21:00 | 2770.42 | 11-JUL-19:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 5.89 | 0.00 | 02-JAN-18:45 | 2677.94 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 17.95 | 0.00 | 01-JAN-00:15 | 2770.42 | 11-JUL-19:00 |
EnergyTransfer:Zone:M N2 APARTMENT | 23.90 | 0.25 | 17-OCT-04:00 | 2762.46 | 11-JUL-19:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 5.86 | 0.00 | 02-JAN-18:45 | 2678.46 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 18.04 | 0.00 | 01-JAN-00:15 | 2762.46 | 11-JUL-19:00 |
EnergyTransfer:Zone:M S1 APARTMENT | 31.45 | 0.06 | 23-FEB-07:00 | 4032.95 | 11-AUG-15:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 3.67 | 0.00 | 02-JAN-18:45 | 2416.94 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 27.78 | 0.00 | 01-JAN-00:15 | 4032.95 | 11-AUG-15:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 31.56 | 0.73 | 06-MAR-02:00 | 4041.10 | 11-AUG-15:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 3.66 | 0.00 | 02-JAN-18:45 | 2416.90 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 27.90 | 0.00 | 01-JAN-00:15 | 4041.10 | 11-AUG-15:15 |
EnergyTransfer:Zone:T SW APARTMENT | 32.85 | 0.07 | 14-JUN-05:15 | 4239.01 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 24.25 | 0.00 | 09-FEB-11:45 | 4239.01 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 8.60 | 0.00 | 01-JAN-00:15 | 3166.12 | 29-JUL-15:30 |
EnergyTransfer:Zone:T NW APARTMENT | 33.13 | 0.34 | 18-SEP-24:00 | 4337.24 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 27.40 | 0.00 | 18-MAR-15:15 | 4337.24 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 5.73 | 0.00 | 01-JAN-00:15 | 2639.27 | 11-JUL-17:45 |
EnergyTransfer:Zone:T SE APARTMENT | 33.27 | 0.04 | 26-JUN-02:00 | 4256.04 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 23.89 | 0.00 | 09-FEB-11:30 | 4256.04 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 9.38 | 0.00 | 01-JAN-00:15 | 3045.38 | 22-JUL-11:45 |
EnergyTransfer:Zone:T NE APARTMENT | 33.52 | 0.03 | 29-AUG-13:30 | 4354.25 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 26.97 | 0.00 | 18-MAR-12:45 | 4354.25 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 6.55 | 0.00 | 01-JAN-00:15 | 2052.70 | 11-JUL-17:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 24.97 | 0.43 | 06-SEP-06:00 | 2970.59 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 19.30 | 0.00 | 18-MAR-11:45 | 2970.59 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 5.67 | 0.00 | 01-JAN-00:15 | 1771.47 | 11-JUL-17:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 25.00 | 0.01 | 19-SEP-16:00 | 2970.95 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 19.28 | 0.00 | 18-MAR-11:45 | 2970.95 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 5.72 | 0.00 | 01-JAN-00:15 | 1762.72 | 11-JUL-17:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 25.10 | 0.45 | 14-FEB-13:00 | 2868.64 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 16.43 | 0.00 | 09-FEB-11:30 | 2868.64 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 8.67 | 0.00 | 01-JAN-00:15 | 2653.82 | 23-JUL-13:45 |
EnergyTransfer:Zone:T S2 APARTMENT | 25.14 | 0.75 | 25-SEP-21:30 | 2869.00 | 29-JAN-00:15 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 16.42 | 0.00 | 09-FEB-11:30 | 2869.00 | 29-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 8.72 | 0.00 | 01-JAN-00:15 | 2668.26 | 23-JUL-13:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 984.44 | 0.00 | 02-JUN-01:45 | 111751.53 | 29-JAN-00:15 |
HeatingCoils:EnergyTransfer | 785.74 | 0.00 | 17-APR-14:00 | 111751.53 | 29-JAN-00:15 |
CoolingCoils:EnergyTransfer | 198.70 | 0.00 | 01-JAN-00:15 | 67288.74 | 29-JUL-16:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 12.203 | -4.989 | 0.000 | 0.000 | 3.924 | 2.413 | 12.213 | 9.390 | 0.000 | 0.008 | 0.000 | 0.000 | -13.793 | 0.000 | -4.195 | -17.173 |
G NW APARTMENT | 14.335 | -3.478 | 0.000 | 0.000 | 3.945 | 2.413 | 12.213 | 3.842 | 0.000 | 0.008 | 0.000 | 0.000 | -14.808 | 0.000 | -4.131 | -14.339 |
OFFICE | 1.687 | -21.964 | 0.000 | 0.000 | 0.554 | 21.914 | 7.534 | 10.581 | 0.000 | 0.005 | 0.000 | 0.000 | -12.469 | 0.000 | -3.265 | -4.577 |
G NE APARTMENT | 14.041 | -4.052 | 0.000 | 0.000 | 3.950 | 2.413 | 12.213 | 4.829 | 0.000 | 0.008 | 0.000 | 0.000 | -14.451 | 0.000 | -4.133 | -14.818 |
G N1 APARTMENT | 8.210 | -3.832 | 0.000 | 0.000 | 3.950 | 2.413 | 12.213 | 1.508 | 0.000 | 0.007 | 0.000 | 0.000 | -9.164 | 0.000 | -2.718 | -12.586 |
G N2 APARTMENT | 8.199 | -3.856 | 0.000 | 0.000 | 3.950 | 2.413 | 12.213 | 1.507 | 0.000 | 0.007 | 0.000 | 0.000 | -9.164 | 0.000 | -2.719 | -12.549 |
G S1 APARTMENT | 6.434 | -5.320 | 0.000 | 0.000 | 3.920 | 2.413 | 12.213 | 7.275 | 0.000 | 0.007 | 0.000 | 0.000 | -8.326 | 0.000 | -2.791 | -15.825 |
G S2 APARTMENT | 7.793 | -5.172 | 0.000 | 0.000 | 3.920 | 2.413 | 12.213 | 7.277 | 0.000 | 0.007 | 0.000 | 0.000 | -8.305 | 0.000 | -2.791 | -17.355 |
M SW APARTMENT | 14.655 | -24.451 | 0.000 | 0.000 | 3.838 | 2.413 | 12.213 | 9.046 | 0.000 | 0.010 | 2.646 | 0.000 | -14.403 | 0.000 | -5.968 | -0.000 |
M NW APARTMENT | 19.140 | -16.489 | 0.000 | 0.000 | 3.867 | 2.413 | 12.213 | 3.524 | 0.000 | 0.011 | 0.000 | 0.000 | -15.377 | 0.000 | -5.926 | -3.376 |
M SE APARTMENT | 14.332 | -26.659 | 0.000 | 0.000 | 3.838 | 2.413 | 12.213 | 10.093 | 0.000 | 0.010 | 3.853 | 0.000 | -14.124 | 0.000 | -5.970 | -0.001 |
M NE APARTMENT | 18.545 | -18.541 | 0.000 | 0.000 | 3.870 | 2.413 | 12.213 | 4.495 | 0.000 | 0.011 | 0.001 | 0.000 | -15.013 | 0.000 | -5.924 | -2.069 |
M N1 APARTMENT | 5.887 | -17.946 | 0.000 | 0.000 | 3.862 | 2.413 | 12.213 | 1.314 | 0.000 | 0.009 | 5.718 | 0.000 | -9.581 | 0.000 | -3.888 | -0.001 |
M N2 APARTMENT | 5.862 | -18.036 | 0.000 | 0.000 | 3.862 | 2.413 | 12.213 | 1.313 | 0.000 | 0.009 | 5.834 | 0.000 | -9.582 | 0.000 | -3.888 | -0.000 |
M S1 APARTMENT | 3.670 | -27.783 | 0.000 | 0.000 | 3.824 | 2.413 | 12.213 | 7.058 | 0.000 | 0.009 | 11.243 | 0.000 | -8.724 | 0.000 | -3.921 | -0.000 |
M S2 APARTMENT | 3.665 | -27.899 | 0.000 | 0.000 | 3.823 | 2.413 | 12.213 | 7.057 | 0.000 | 0.009 | 11.366 | 0.000 | -8.725 | 0.000 | -3.922 | -0.001 |
T SW APARTMENT | 24.246 | -8.599 | 0.000 | 0.000 | 3.895 | 2.413 | 12.213 | 9.050 | 0.000 | 0.014 | 0.000 | 0.000 | -13.819 | 0.000 | -7.613 | -21.799 |
T NW APARTMENT | 27.396 | -5.731 | 0.000 | 0.000 | 3.917 | 2.413 | 12.213 | 3.553 | 0.000 | 0.014 | 0.000 | 0.000 | -14.796 | 0.000 | -7.561 | -21.419 |
T SE APARTMENT | 23.892 | -9.380 | 0.000 | 0.000 | 3.894 | 2.413 | 12.213 | 10.127 | 0.000 | 0.014 | 0.000 | 0.000 | -13.581 | 0.000 | -7.617 | -21.974 |
T NE APARTMENT | 26.972 | -6.546 | 0.000 | 0.000 | 3.922 | 2.413 | 12.213 | 4.546 | 0.000 | 0.014 | 0.000 | 0.000 | -14.460 | 0.000 | -7.557 | -21.517 |
T N1 APARTMENT | 19.297 | -5.673 | 0.000 | 0.000 | 3.919 | 2.413 | 12.213 | 1.350 | 0.000 | 0.012 | 0.000 | 0.000 | -9.171 | 0.000 | -4.884 | -19.475 |
T N2 APARTMENT | 19.281 | -5.717 | 0.000 | 0.000 | 3.919 | 2.413 | 12.213 | 1.348 | 0.000 | 0.012 | 0.000 | 0.000 | -9.171 | 0.000 | -4.885 | -19.413 |
T S1 APARTMENT | 16.431 | -8.668 | 0.000 | 0.000 | 3.885 | 2.413 | 12.213 | 7.073 | 0.000 | 0.012 | 0.000 | 0.000 | -8.367 | 0.000 | -4.931 | -20.062 |
T S2 APARTMENT | 16.419 | -8.723 | 0.000 | 0.000 | 3.885 | 2.413 | 12.213 | 7.071 | 0.000 | 0.012 | 0.000 | 0.000 | -8.367 | 0.000 | -4.932 | -19.990 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.015 | 0.000 | 0.000 | 0.000 | 0.000 | -1.601 | 0.000 | -1.202 | -14.281 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 6.264 | 0.077 | 0.000 | 0.007 | 21.497 | 0.000 | -4.357 | 0.000 | -40.559 | -0.001 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | 0.000 | 0.015 | 0.000 | 0.000 | 0.000 | 0.000 | -1.748 | 0.000 | -0.984 | -14.353 |
Total Facility | 332.592 | -289.501 | 0.000 | 0.000 | 90.133 | 128.627 | 294.692 | 134.334 | 0.000 | 0.243 | 62.158 | 0.000 | -285.449 | 0.000 | -158.875 | -308.957 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 11-AUG-16:15 | 0.00 | -1693.00 | 0.00 | 0.00 | 84.75 | 144.04 | 588.62 | 2156.61 | 0.00 | 48.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1329.74 |
G NW APARTMENT | 11-JUL-17:45 | 0.00 | -1372.39 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 1635.87 | 0.00 | 74.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1262.61 |
OFFICE | 10-AUG-13:30 | 0.00 | -3248.89 | 0.00 | 0.00 | 67.31 | 1622.34 | 544.92 | 2557.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -16.10 | -1527.35 |
G NE APARTMENT | 11-JUL-17:15 | 0.00 | -1009.72 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 412.89 | 0.00 | 74.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -402.93 |
G N1 APARTMENT | 25-OCT-18:20 | 0.00 | -873.29 | 0.00 | 0.00 | 165.01 | 230.46 | 547.42 | 0.00 | 0.00 | 0.00 | 425.95 | 0.00 | -460.70 | 0.00 | -34.85 | 0.00 |
G N2 APARTMENT | 25-OCT-18:20 | 0.00 | -874.95 | 0.00 | 0.00 | 165.01 | 230.46 | 547.42 | 0.00 | 0.00 | 0.00 | 427.61 | 0.00 | -460.70 | 0.00 | -34.85 | 0.00 |
G S1 APARTMENT | 11-AUG-15:15 | 0.00 | -1264.51 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1711.94 | 0.00 | 10.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1078.34 |
G S2 APARTMENT | 11-AUG-15:15 | 0.00 | -1246.15 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1712.20 | 0.00 | 10.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1096.96 |
M SW APARTMENT | 11-AUG-16:15 | 0.00 | -5092.44 | 0.00 | 0.00 | 84.76 | 144.04 | 588.62 | 2136.70 | 0.00 | 66.36 | 2071.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 11-JUL-18:15 | 0.00 | -4159.67 | 0.00 | 0.00 | 141.81 | 230.46 | 547.42 | 1470.68 | 0.00 | 100.85 | 1668.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 22-JUL-11:30 | 0.00 | -4884.63 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 2744.84 | 0.00 | 36.25 | 1627.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 11-JUL-17:15 | 0.00 | -3402.25 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 395.62 | 0.00 | 102.00 | 1979.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 11-JUL-19:00 | 0.00 | -2770.14 | 0.00 | 0.00 | 141.80 | 230.46 | 547.42 | 262.01 | 0.00 | 84.08 | 1504.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 11-JUL-19:00 | 0.00 | -2762.18 | 0.00 | 0.00 | 141.80 | 230.46 | 547.42 | 262.05 | 0.00 | 84.08 | 1496.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 11-AUG-15:15 | 0.00 | -4033.22 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1698.77 | 0.00 | 13.65 | 1700.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 11-AUG-15:15 | 0.00 | -4041.37 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 1698.71 | 0.00 | 13.65 | 1708.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 29-JUL-15:30 | 0.00 | -3166.27 | 0.00 | 0.00 | 48.90 | 100.83 | 470.90 | 2487.83 | 0.00 | 91.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -33.22 |
T NW APARTMENT | 11-JUL-17:45 | 0.00 | -2638.86 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 1592.89 | 0.00 | 128.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.02 |
T SE APARTMENT | 22-JUL-11:45 | 0.00 | -3045.17 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 2537.02 | 0.00 | 69.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -36.88 |
T NE APARTMENT | 11-JUL-17:15 | 0.00 | -2052.37 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 380.66 | 0.00 | 129.37 | 617.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 11-JUL-17:15 | 0.00 | -1771.18 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 234.65 | 0.00 | 114.60 | 497.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 11-JUL-17:15 | 0.00 | -1762.43 | 0.00 | 0.00 | 141.81 | 194.45 | 588.62 | 234.77 | 0.00 | 114.60 | 488.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 23-JUL-13:45 | 0.00 | -2653.62 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2126.17 | 0.00 | 15.56 | 59.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 23-JUL-13:45 | 0.00 | -2668.06 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2125.98 | 0.00 | 15.56 | 74.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 11-JUL-17:15 | 0.00 | -56012.02 | 0.00 | 0.00 | 3261.52 | 6475.86 | 14071.03 | 17975.34 | 0.00 | 2106.48 | 12163.58 | 0.00 | 0.00 | 0.00 | -41.80 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 29-JAN-00:15 | 2264.26 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1122.47 | 0.00 | -1118.80 | -491.94 |
G NW APARTMENT | 29-JAN-00:15 | 2344.93 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1144.65 | 0.00 | -1118.80 | -550.43 |
OFFICE | 24-DEC-07:01 | 6929.63 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.70 | 0.00 | -154.77 | -6889.72 |
G NE APARTMENT | 29-JAN-00:15 | 2356.44 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1161.58 | 0.00 | -1118.80 | -545.01 |
G N1 APARTMENT | 29-JAN-00:15 | 1456.40 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -704.32 | 0.00 | -674.83 | -546.20 |
G N2 APARTMENT | 12-OCT-16:01 | 1546.87 | 0.00 | 0.00 | 0.00 | 98.71 | 144.04 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -314.23 | 0.00 | -81.69 | -1982.32 |
G S1 APARTMENT | 16-OCT-06:01 | 1604.84 | 0.00 | 0.00 | 0.00 | 161.43 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -349.29 | 0.00 | -75.55 | -1817.66 |
G S2 APARTMENT | 15-OCT-06:01 | 1620.71 | 0.00 | 0.00 | 0.00 | 161.44 | 93.63 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -343.26 | 0.00 | -83.84 | -1831.28 |
M SW APARTMENT | 29-JAN-00:15 | 4728.36 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1147.52 | 0.00 | -1608.50 | -2441.29 |
M NW APARTMENT | 29-JAN-00:15 | 4993.41 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1171.90 | 0.00 | -1608.50 | -2681.96 |
M SE APARTMENT | 29-JAN-00:15 | 4752.62 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1166.58 | 0.00 | -1608.50 | -2446.50 |
M NE APARTMENT | 29-JAN-00:15 | 5018.35 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1190.86 | 0.00 | -1608.50 | -2687.94 |
M N1 APARTMENT | 14-FEB-08:01 | 3730.20 | 0.00 | 0.00 | 0.00 | 74.13 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -543.46 | 0.00 | 0.00 | -3692.57 |
M N2 APARTMENT | 09-DEC-18:07 | 3471.49 | 0.00 | 0.00 | 0.00 | 165.01 | 194.45 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -591.22 | 0.00 | -32.82 | -3795.54 |
M S1 APARTMENT | 13-JAN-18:07 | 3268.89 | 0.00 | 0.00 | 0.00 | 165.01 | 194.45 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -579.73 | 0.00 | 0.00 | -3637.25 |
M S2 APARTMENT | 13-JAN-18:07 | 3265.22 | 0.00 | 0.00 | 0.00 | 165.01 | 194.45 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -579.73 | 0.00 | 0.00 | -3633.58 |
T SW APARTMENT | 29-JAN-00:15 | 4238.99 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1121.92 | 0.00 | -2129.39 | -1456.63 |
T NW APARTMENT | 29-JAN-00:15 | 4337.22 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1147.53 | 0.00 | -2129.39 | -1529.26 |
T SE APARTMENT | 29-JAN-00:15 | 4256.02 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1141.68 | 0.00 | -2129.39 | -1453.90 |
T NE APARTMENT | 29-JAN-00:15 | 4354.22 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1167.23 | 0.00 | -2129.39 | -1526.56 |
T N1 APARTMENT | 29-JAN-00:15 | 2970.58 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -707.92 | 0.00 | -1284.44 | -1447.18 |
T N2 APARTMENT | 29-JAN-00:15 | 2970.94 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -707.91 | 0.00 | -1284.44 | -1447.54 |
T S1 APARTMENT | 29-JAN-00:15 | 2868.64 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -682.00 | 0.00 | -1284.44 | -1371.15 |
T S2 APARTMENT | 29-JAN-00:15 | 2869.00 | 0.00 | 0.00 | 0.00 | 189.67 | 14.40 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -682.00 | 0.00 | -1284.44 | -1371.51 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 29-JAN-00:15 | 71902.86 | 0.00 | 0.00 | 0.00 | 4362.43 | 2334.74 | 6261.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -22589.90 | 0.00 | -31808.10 | -30463.36 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Sec1.1A-General InformationData | |
Weather File | Fairbanks Intl Arpt AK USA TMY3 WMO#=702610 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 27.25 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 27.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 165.00 | 9689.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 39.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 982.18 | 139689.41 | 0.00 | 0.00 |
Space Cooling | 49.81 | 14959.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 214.76 | 6809.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 500.66 | 31184.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 511.42 | 23563.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1480.75 | 982.18 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 511.42 | 1480.75 |
Natural Gas | 0.00 | 982.18 |
Additional | 0.00 | 0.00 |
Total | 511.42 | 2462.93 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 52.64 |
Space Heating | 0.00 |
Space Cooling | 15.89 |
Fans-Interior | 68.51 |
Service Water Heating | 159.72 |
Receptacle Equipment | 163.15 |
Miscellaneous | 12.48 |
Subtotal | 472.39 |
Natural Gas [MJ/m2] | |
Space Heating | 313.33 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 313.33 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.70 |
Space Heating | 39.88 |
Space Cooling | 2.02 |
Fans-Interior | 8.72 |
Service Water Heating | 20.33 |
Receptacle Equipment | 20.76 |
Miscellaneous | 1.59 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.166650 |
G NW APARTMENT DIRECT AIR | 0.134581 |
OFFICE DIRECT AIR | 0.422541 |
G NE APARTMENT DIRECT AIR | 0.093014 |
G N1 APARTMENT DIRECT AIR | 0.082285 |
G N2 APARTMENT DIRECT AIR | 0.081185 |
G S1 APARTMENT DIRECT AIR | 0.125538 |
G S2 APARTMENT DIRECT AIR | 0.128600 |
M SW APARTMENT DIRECT AIR | 0.493165 |
M NW APARTMENT DIRECT AIR | 0.402451 |
M SE APARTMENT DIRECT AIR | 0.468381 |
M NE APARTMENT DIRECT AIR | 0.314931 |
M N1 APARTMENT DIRECT AIR | 0.263324 |
M N2 APARTMENT DIRECT AIR | 0.261280 |
M S1 APARTMENT DIRECT AIR | 0.385218 |
M S2 APARTMENT DIRECT AIR | 0.386497 |
T SW APARTMENT DIRECT AIR | 0.313175 |
T NW APARTMENT DIRECT AIR | 0.244270 |
T SE APARTMENT DIRECT AIR | 0.298984 |
T NE APARTMENT DIRECT AIR | 0.187413 |
T N1 APARTMENT DIRECT AIR | 0.153311 |
T N2 APARTMENT DIRECT AIR | 0.151168 |
T S1 APARTMENT DIRECT AIR | 0.260360 |
T S2 APARTMENT DIRECT AIR | 0.261345 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.166650 |
SPLIT GNW MAIN BRANCH | 0.134581 |
SPLIT OFFICE MAIN BRANCH | 0.422541 |
SPLIT GNE MAIN BRANCH | 0.093014 |
SPLIT GN1 MAIN BRANCH | 0.082285 |
SPLIT GN2 MAIN BRANCH | 0.081185 |
SPLIT GS1 MAIN BRANCH | 0.125538 |
SPLIT GS2 MAIN BRANCH | 0.128600 |
SPLIT MSW MAIN BRANCH | 0.493165 |
SPLIT MNW MAIN BRANCH | 0.402451 |
SPLIT MSE MAIN BRANCH | 0.468381 |
SPLIT MNE MAIN BRANCH | 0.314931 |
SPLIT MN1 MAIN BRANCH | 0.263324 |
SPLIT MN2 MAIN BRANCH | 0.261280 |
SPLIT MS1 MAIN BRANCH | 0.385218 |
SPLIT MS2 MAIN BRANCH | 0.386497 |
SPLIT TSW MAIN BRANCH | 0.313175 |
SPLIT TNW MAIN BRANCH | 0.244270 |
SPLIT TSE MAIN BRANCH | 0.298984 |
SPLIT TNE MAIN BRANCH | 0.187413 |
SPLIT TN1 MAIN BRANCH | 0.153311 |
SPLIT TN2 MAIN BRANCH | 0.151168 |
SPLIT TS1 MAIN BRANCH | 0.260360 |
SPLIT TS2 MAIN BRANCH | 0.261345 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.166650 |
SPLIT GNW | 0.134581 |
SPLIT OFFICE | 0.422541 |
SPLIT GNE | 0.093014 |
SPLIT GN1 | 0.082285 |
SPLIT GN2 | 0.081185 |
SPLIT GS1 | 0.125538 |
SPLIT GS2 | 0.128600 |
SPLIT MSW | 0.493165 |
SPLIT MNW | 0.402451 |
SPLIT MSE | 0.468381 |
SPLIT MNE | 0.314931 |
SPLIT MN1 | 0.263324 |
SPLIT MN2 | 0.261280 |
SPLIT MS1 | 0.385218 |
SPLIT MS2 | 0.386497 |
SPLIT TSW | 0.313175 |
SPLIT TNW | 0.244270 |
SPLIT TSE | 0.298984 |
SPLIT TNE | 0.187413 |
SPLIT TN1 | 0.153311 |
SPLIT TN2 | 0.151168 |
SPLIT TS1 | 0.260360 |
SPLIT TS2 | 0.261345 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.166650 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.134581 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.422541 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.093014 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.082285 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.081185 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.125538 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.128600 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.493165 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.402451 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.468381 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.314931 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.263324 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.261280 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.385218 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.386497 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.313175 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.244270 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.298984 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.187413 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.153311 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.151168 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.260360 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.261345 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.166650 | 2758.65 | 0.798655 |
SPLIT GNW COOLING COIL | 0.134581 | 2227.79 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.422541 | 6994.56 | 0.798655 |
SPLIT GNE COOLING COIL | 0.093014 | 1539.71 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.082285 | 1362.11 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.081185 | 1343.90 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.125538 | 2078.10 | 0.798655 |
SPLIT GS2 COOLING COIL | 0.128600 | 2128.78 | 0.798655 |
SPLIT MSW COOLING COIL | 0.493165 | 8163.63 | 0.798655 |
SPLIT MNW COOLING COIL | 0.402451 | 6662.00 | 0.798655 |
SPLIT MSE COOLING COIL | 0.468381 | 7753.37 | 0.798655 |
SPLIT MNE COOLING COIL | 0.314931 | 5213.23 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.263324 | 4358.95 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.261280 | 4325.12 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.385218 | 6376.73 | 0.798655 |
SPLIT MS2 COOLING COIL | 0.386497 | 6397.90 | 0.798655 |
SPLIT TSW COOLING COIL | 0.313175 | 5184.17 | 0.798655 |
SPLIT TNW COOLING COIL | 0.244270 | 4043.53 | 0.798655 |
SPLIT TSE COOLING COIL | 0.298984 | 4949.24 | 0.798655 |
SPLIT TNE COOLING COIL | 0.187413 | 3102.35 | 0.798655 |
SPLIT TN1 COOLING COIL | 0.153311 | 2537.85 | 0.798655 |
SPLIT TN2 COOLING COIL | 0.151168 | 2502.36 | 0.798655 |
SPLIT TS1 COOLING COIL | 0.260360 | 4309.88 | 0.798655 |
SPLIT TS2 COOLING COIL | 0.261345 | 4326.19 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.166650 | 0.166650 | 0.166650 | 0.166650 | 4380.83 | 2758.65 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.134581 | 0.134581 | 0.134581 | 0.134581 | 4322.48 | 2227.79 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.422541 | 0.422541 | 0.422541 | 0.422541 | 7635.65 | 6994.56 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.093014 | 0.093014 | 0.093014 | 0.093014 | 4328.50 | 1539.71 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.082285 | 0.082285 | 0.082285 | 0.082285 | 3561.71 | 1362.11 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.081185 | 0.081185 | 0.081185 | 0.081185 | 3561.83 | 1343.90 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.125538 | 0.125538 | 0.125538 | 0.125538 | 3552.15 | 2078.10 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.128600 | 0.128600 | 0.128600 | 0.128600 | 3692.52 | 2128.78 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.493165 | 0.493165 | 0.493165 | 0.493165 | 7564.91 | 8163.63 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.402451 | 0.402451 | 0.402451 | 0.402451 | 7593.70 | 6662.00 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.468381 | 0.468381 | 0.468381 | 0.468381 | 7580.91 | 7753.37 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.314931 | 0.314931 | 0.314931 | 0.314931 | 7609.73 | 5213.23 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.263324 | 0.263324 | 0.263324 | 0.263324 | 5818.98 | 4358.95 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.261280 | 0.261280 | 0.261280 | 0.261280 | 5819.35 | 4325.12 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.385218 | 0.385218 | 0.385218 | 0.385218 | 5793.87 | 6376.73 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.386497 | 0.386497 | 0.386497 | 0.386497 | 5794.23 | 6397.90 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.313175 | 0.313175 | 0.313175 | 0.313175 | 5899.17 | 5184.17 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.244270 | 0.244270 | 0.244270 | 0.244270 | 5917.55 | 4043.53 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.298984 | 0.298984 | 0.298984 | 0.298984 | 5907.98 | 4949.24 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.187413 | 0.187413 | 0.187413 | 0.187413 | 5926.38 | 3102.35 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.153311 | 0.153311 | 0.153311 | 0.153311 | 5041.35 | 2537.85 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.151168 | 0.151168 | 0.151168 | 0.151168 | 5041.56 | 2502.36 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.260360 | 0.260360 | 0.260360 | 0.260360 | 5021.53 | 4309.88 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.261345 | 0.261345 | 0.261345 | 0.261345 | 5021.73 | 4326.19 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.166650 |
SPLIT GNW SUPPLY FAN | 0.134581 |
SPLIT OFFICE SUPPLY FAN | 0.422541 |
SPLIT GNE SUPPLY FAN | 0.093014 |
SPLIT GN1 SUPPLY FAN | 0.082285 |
SPLIT GN2 SUPPLY FAN | 0.081185 |
SPLIT GS1 SUPPLY FAN | 0.125538 |
SPLIT GS2 SUPPLY FAN | 0.128600 |
SPLIT MSW SUPPLY FAN | 0.493165 |
SPLIT MNW SUPPLY FAN | 0.402451 |
SPLIT MSE SUPPLY FAN | 0.468381 |
SPLIT MNE SUPPLY FAN | 0.314931 |
SPLIT MN1 SUPPLY FAN | 0.263324 |
SPLIT MN2 SUPPLY FAN | 0.261280 |
SPLIT MS1 SUPPLY FAN | 0.385218 |
SPLIT MS2 SUPPLY FAN | 0.386497 |
SPLIT TSW SUPPLY FAN | 0.313175 |
SPLIT TNW SUPPLY FAN | 0.244270 |
SPLIT TSE SUPPLY FAN | 0.298984 |
SPLIT TNE SUPPLY FAN | 0.187413 |
SPLIT TN1 SUPPLY FAN | 0.153311 |
SPLIT TN2 SUPPLY FAN | 0.151168 |
SPLIT TS1 SUPPLY FAN | 0.260360 |
SPLIT TS2 SUPPLY FAN | 0.261345 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 4380.83 |
SPLIT GNW HEATING COIL | 4322.48 |
SPLIT OFFICE HEATING COIL | 7635.65 |
SPLIT GNE HEATING COIL | 4328.50 |
SPLIT GN1 HEATING COIL | 3561.71 |
SPLIT GN2 HEATING COIL | 3561.83 |
SPLIT GS1 HEATING COIL | 3552.15 |
SPLIT GS2 HEATING COIL | 3692.52 |
SPLIT MSW HEATING COIL | 7564.91 |
SPLIT MNW HEATING COIL | 7593.70 |
SPLIT MSE HEATING COIL | 7580.91 |
SPLIT MNE HEATING COIL | 7609.73 |
SPLIT MN1 HEATING COIL | 5818.98 |
SPLIT MN2 HEATING COIL | 5819.35 |
SPLIT MS1 HEATING COIL | 5793.87 |
SPLIT MS2 HEATING COIL | 5794.23 |
SPLIT TSW HEATING COIL | 5899.17 |
SPLIT TNW HEATING COIL | 5917.55 |
SPLIT TSE HEATING COIL | 5907.98 |
SPLIT TNE HEATING COIL | 5926.38 |
SPLIT TN1 HEATING COIL | 5041.35 |
SPLIT TN2 HEATING COIL | 5041.56 |
SPLIT TS1 HEATING COIL | 5021.53 |
SPLIT TS2 HEATING COIL | 5021.73 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:20:32
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.07 | 0.73 |
May | 22.69 | 10.60 |
June | 24.13 | 15.96 |
July | 24.26 | 16.86 |
August | 24.05 | 14.24 |
September | 22.90 | 6.72 |
October | 21.74 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.53 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.26 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 21.78 | 0.73 |
May | 22.23 | 10.60 |
June | 24.06 | 15.96 |
July | 24.22 | 16.86 |
August | 23.86 | 14.24 |
September | 22.46 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.41 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.22 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.45 | -17.6 |
February | 17.88 | -15.4 |
March | 18.72 | -10.3 |
April | 21.02 | 0.73 |
May | 22.92 | 10.60 |
June | 23.87 | 15.96 |
July | 23.89 | 16.86 |
August | 23.82 | 14.24 |
September | 23.09 | 6.72 |
October | 20.09 | -3.1 |
November | 17.49 | -17.6 |
December | 17.29 | -19.3 |
Annual Sum or Average | 20.64 | -1.4 |
Minimum of Months | 17.29 | -19.3 |
Maximum of Months | 23.89 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 21.74 | 0.73 |
May | 22.31 | 10.60 |
June | 24.07 | 15.96 |
July | 24.20 | 16.86 |
August | 23.86 | 14.24 |
September | 22.41 | 6.72 |
October | 21.70 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.40 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.20 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 21.73 | 0.73 |
May | 22.05 | 10.60 |
June | 23.98 | 15.96 |
July | 24.19 | 16.86 |
August | 23.84 | 14.24 |
September | 22.51 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.38 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.19 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 21.72 | 0.73 |
May | 22.06 | 10.60 |
June | 23.99 | 15.96 |
July | 24.19 | 16.86 |
August | 23.84 | 14.24 |
September | 22.51 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.38 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.19 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.03 | 0.73 |
May | 22.61 | 10.60 |
June | 24.14 | 15.96 |
July | 24.28 | 16.86 |
August | 24.13 | 14.24 |
September | 23.11 | 6.72 |
October | 21.76 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.55 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.28 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.02 | 0.73 |
May | 22.63 | 10.60 |
June | 24.14 | 15.96 |
July | 24.27 | 16.86 |
August | 24.12 | 14.24 |
September | 23.12 | 6.72 |
October | 21.77 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.55 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.27 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.79 | -10.3 |
April | 23.07 | 0.73 |
May | 24.25 | 10.60 |
June | 24.39 | 15.96 |
July | 24.40 | 16.86 |
August | 24.36 | 14.24 |
September | 23.75 | 6.72 |
October | 22.06 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.91 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.36 | 0.73 |
May | 24.12 | 10.60 |
June | 24.39 | 15.96 |
July | 24.40 | 16.86 |
August | 24.31 | 14.24 |
September | 23.31 | 6.72 |
October | 21.76 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.77 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.81 | -10.3 |
April | 23.07 | 0.73 |
May | 24.26 | 10.60 |
June | 24.39 | 15.96 |
July | 24.40 | 16.86 |
August | 24.37 | 14.24 |
September | 23.78 | 6.72 |
October | 22.11 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.92 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.30 | 0.73 |
May | 24.12 | 10.60 |
June | 24.39 | 15.96 |
July | 24.40 | 16.86 |
August | 24.33 | 14.24 |
September | 23.32 | 6.72 |
October | 21.76 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.77 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.30 | 0.73 |
May | 24.20 | 10.60 |
June | 24.40 | 15.96 |
July | 24.40 | 16.86 |
August | 24.34 | 14.24 |
September | 23.50 | 6.72 |
October | 21.82 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.80 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.29 | 0.73 |
May | 24.20 | 10.60 |
June | 24.40 | 15.96 |
July | 24.40 | 16.86 |
August | 24.34 | 14.24 |
September | 23.50 | 6.72 |
October | 21.82 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.80 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.71 | -15.4 |
March | 21.87 | -10.3 |
April | 23.26 | 0.73 |
May | 24.32 | 10.60 |
June | 24.40 | 15.96 |
July | 24.40 | 16.86 |
August | 24.38 | 14.24 |
September | 23.99 | 6.72 |
October | 22.29 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.98 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.71 | -15.4 |
March | 21.88 | -10.3 |
April | 23.26 | 0.73 |
May | 24.33 | 10.60 |
June | 24.40 | 15.96 |
July | 24.40 | 16.86 |
August | 24.38 | 14.24 |
September | 23.99 | 6.72 |
October | 22.30 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.99 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.40 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.77 | -10.3 |
April | 22.58 | 0.73 |
May | 23.58 | 10.60 |
June | 24.29 | 15.96 |
July | 24.35 | 16.86 |
August | 24.12 | 14.24 |
September | 22.75 | 6.72 |
October | 21.79 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.67 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.35 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.12 | 0.73 |
May | 23.36 | 10.60 |
June | 24.28 | 15.96 |
July | 24.32 | 16.86 |
August | 23.94 | 14.24 |
September | 22.28 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.55 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.32 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.78 | -10.3 |
April | 22.60 | 0.73 |
May | 23.67 | 10.60 |
June | 24.30 | 15.96 |
July | 24.34 | 16.86 |
August | 24.14 | 14.24 |
September | 22.79 | 6.72 |
October | 21.80 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.69 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.34 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.08 | 0.73 |
May | 23.46 | 10.60 |
June | 24.26 | 15.96 |
July | 24.29 | 16.86 |
August | 23.92 | 14.24 |
September | 22.27 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.55 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.29 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.03 | 0.73 |
May | 23.37 | 10.60 |
June | 24.30 | 15.96 |
July | 24.32 | 16.86 |
August | 23.94 | 14.24 |
September | 22.23 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.54 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.32 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.70 | -10.3 |
April | 22.03 | 0.73 |
May | 23.39 | 10.60 |
June | 24.30 | 15.96 |
July | 24.32 | 16.86 |
August | 23.94 | 14.24 |
September | 22.23 | 6.72 |
October | 21.71 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.54 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.32 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.78 | -10.3 |
April | 22.62 | 0.73 |
May | 23.70 | 10.60 |
June | 24.33 | 15.96 |
July | 24.37 | 16.86 |
August | 24.19 | 14.24 |
September | 22.88 | 6.72 |
October | 21.84 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.72 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.37 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -17.6 |
February | 21.70 | -15.4 |
March | 21.79 | -10.3 |
April | 22.63 | 0.73 |
May | 23.71 | 10.60 |
June | 24.33 | 15.96 |
July | 24.37 | 16.86 |
August | 24.19 | 14.24 |
September | 22.89 | 6.72 |
October | 21.84 | -3.1 |
November | 21.70 | -17.6 |
December | 21.70 | -19.3 |
Annual Sum or Average | 22.72 | -1.4 |
Minimum of Months | 21.70 | -19.3 |
Maximum of Months | 24.37 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.62 | -17.6 |
February | 19.97 | -15.4 |
March | 20.72 | -10.3 |
April | 22.61 | 0.73 |
May | 24.95 | 10.60 |
June | 26.36 | 15.96 |
July | 26.44 | 16.86 |
August | 25.73 | 14.24 |
September | 23.22 | 6.72 |
October | 21.20 | -3.1 |
November | 19.75 | -17.6 |
December | 19.48 | -19.3 |
Annual Sum or Average | 22.52 | -1.4 |
Minimum of Months | 19.48 | -19.3 |
Maximum of Months | 26.44 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.87 | -17.6 |
February | 17.34 | -15.4 |
March | 18.22 | -10.3 |
April | 20.27 | 0.73 |
May | 22.32 | 10.60 |
June | 24.78 | 15.96 |
July | 25.19 | 16.86 |
August | 24.62 | 14.24 |
September | 22.73 | 6.72 |
October | 19.61 | -3.1 |
November | 17.11 | -17.6 |
December | 16.68 | -19.3 |
Annual Sum or Average | 20.50 | -1.4 |
Minimum of Months | 16.68 | -19.3 |
Maximum of Months | 25.19 | 16.86 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:20:32
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.36 | -17.6 |
February | 22.66 | -15.4 |
March | 23.14 | -10.3 |
April | 24.62 | 0.73 |
May | 26.51 | 10.60 |
June | 26.95 | 15.96 |
July | 26.95 | 16.86 |
August | 26.73 | 14.24 |
September | 25.66 | 6.72 |
October | 23.44 | -3.1 |
November | 22.51 | -17.6 |
December | 22.28 | -19.3 |
Annual Sum or Average | 24.49 | -1.4 |
Minimum of Months | 22.28 | -19.3 |
Maximum of Months | 26.95 | 16.86 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:32
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.125350E+12 | 77005.147 | 30-JAN-18:45 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32657.744 | 0.000 | 0.000 | 0.000 |
February | 0.112382E+12 | 77005.192 | 26-FEB-18:45 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32657.788 | 0.000 | 0.000 | 0.000 |
March | 0.123549E+12 | 77004.904 | 01-MAR-18:45 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32657.501 | 0.000 | 0.000 | 0.000 |
April | 0.119928E+12 | 79322.955 | 22-APR-17:30 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 5186.635 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32297.247 | 0.000 | 0.000 | 0.000 |
May | 0.127552E+12 | 78996.594 | 10-MAY-17:15 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 8343.651 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28813.869 | 0.000 | 0.000 | 0.000 |
June | 0.128439E+12 | 83869.071 | 29-JUN-17:30 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 14035.524 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27994.473 | 0.000 | 0.000 | 0.000 |
July | 0.133482E+12 | 86205.636 | 29-JUL-18:15 | 9689.078 | 23563.017 | 6809.886 | 0.000 | 14959.487 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 31184.169 | 0.000 | 0.000 | 0.000 |
August | 0.128421E+12 | 83138.732 | 23-AUG-17:00 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 12321.832 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28977.827 | 0.000 | 0.000 | 0.000 |
September | 0.117086E+12 | 74620.499 | 01-SEP-17:15 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 4654.121 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28127.305 | 0.000 | 0.000 | 0.000 |
October | 0.120651E+12 | 74727.816 | 31-OCT-17:00 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30380.412 | 0.000 | 0.000 | 0.000 |
November | 0.118853E+12 | 76888.186 | 28-NOV-18:45 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32540.782 | 0.000 | 0.000 | 0.000 |
December | 0.125060E+12 | 77002.596 | 31-DEC-18:15 | 8572.775 | 26456.413 | 6809.886 | 0.000 | 0.000 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32655.193 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.148075E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.112382E+12 | 74620.499 | 8572.775 | 23563.017 | 6809.886 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27994.473 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.133482E+12 | 86205.636 | 9689.078 | 26456.413 | 6809.886 | 0.000 | 14959.487 | 2508.330 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32657.788 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:20:32
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.196668E+12 | 139689.409 | 29-JAN-00:15 | 139689.409 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 139689.409 |
February | 0.150126E+12 | 120183.943 | 25-FEB-00:00 | 120183.943 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 120183.943 |
March | 0.119104E+12 | 105638.311 | 02-MAR-04:00 | 105638.311 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 105638.311 |
April | 0.430948E+11 | 83010.301 | 03-APR-02:00 | 83010.301 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 83010.301 |
May | 0.362246E+10 | 19557.694 | 28-MAY-02:00 | 19557.694 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19557.694 |
June | 0.000 | 0.000 | 01-JUN-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.492991E+09 | 10497.026 | 31-AUG-03:00 | 10497.026 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10497.026 |
September | 0.889822E+10 | 32057.316 | 30-SEP-04:00 | 32057.316 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32057.316 |
October | 0.809562E+11 | 83779.090 | 27-OCT-03:00 | 83779.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 83779.090 |
November | 0.172086E+12 | 111738.775 | 29-NOV-07:00 | 111738.775 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 111738.775 |
December | 0.207128E+12 | 119594.006 | 15-DEC-09:15 | 119594.006 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 119594.006 |
Annual Sum or Average | 0.982176E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.207128E+12 | 139689.409 | 139689.409 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 139689.409 |