Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:45
Tabular Output Report in Format: HTML
Building: Small Office
Environment: Miami Intl Ap FL USA TMY3 WMO#=722020
Simulation Timestamp: 2015-09-09 18:45:38
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 228.25 | 446.53 | 446.53 |
Net Site Energy | 228.25 | 446.53 | 446.53 |
Total Source Energy | 722.85 | 1414.15 | 1414.15 |
Net Source Energy | 722.85 | 1414.15 | 1414.15 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 511.16 |
Net Conditioned Building Area | 511.16 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 46.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 72.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 14.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 52.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 23.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 18.04 | 0.00 | 0.00 | 0.00 | 0.00 | 58.31 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 228.25 | 0.00 | 0.00 | 0.00 | 0.00 | 58.31 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 46.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | General | 72.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 14.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | General | 52.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Fan Energy | 23.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 18.04 | 0.00 | 0.00 | 0.00 | 0.00 | 29.16 |
General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.16 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 170.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 172.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Other | 103.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 170.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 172.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Other | 103.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 228.25 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 228.25 | 100.00 |
Total On-Site and Utility Electric Sources | 228.25 | 100.00 |
Total Electricity End Uses | 228.25 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 58.31 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 58.31 | 100.00 |
Total Water End Uses | 58.31 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 278.33 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1500.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |OUTDOOR AIR SUMMARY
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |VENTILATION LOAD COMPONENTS
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |OVERALL HVAC AIR SYSTEM LOADS
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |OVERALL HVAC SYSTEM ENERGY
| Meter |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK NET ELECTRICAL DEMAND
| Meter |SETPOINTS NOT MET WITH TEMPERATURES
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |COMFORT REPORT - SIMPLE 55
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |BUILDING LOADS - COOLING
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |BUILDING LOADS - HEATING
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |BUILDING LOADS - ELECTRIC
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |SPACE LOADS
| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |ENERGY CONSUMPTION - ELECTRICITY & NATURAL GAS
| Meter |BUILDING ENERGY PERFORMANCE - ELECTRICITY
| Meter |BUILDING ENERGY PERFORMANCE - NATURAL GAS
| Meter |PEAK ENERGY END-USE - ELECTRICITY PART 1
| Meter |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:45 |
RunPeriod | Miami Intl Ap FL USA TMY3 WMO#=722020 |
Weather File | Miami Intl Ap FL USA TMY3 WMO#=722020 |
Latitude [deg] | 25.82 |
Longitude [deg] | -80.3 |
Elevation [m] | 11.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 281.51 | 84.45 | 56.30 | 84.45 | 56.30 |
Window Opening Area [m2] | 59.68 | 16.73 | 11.16 | 20.64 | 11.16 |
Window-Wall Ratio [%] | 21.20 | 19.81 | 19.81 | 24.44 | 19.81 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 281.51 | 84.45 | 56.30 | 84.45 | 56.30 |
Window Opening Area [m2] | 59.68 | 16.73 | 11.16 | 20.64 | 11.16 |
Window-Wall Ratio [%] | 21.20 | 19.81 | 19.81 | 24.44 | 19.81 |
Total | |
Gross Roof Area [m2] | 598.76 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_ZN | 149.66 | Yes | Yes | 456.46 | 1.00 | 0.00 | 0.00 | 10.7639 | 16.59 | 6.7800 |
PERIMETER_ZN_1 | 113.45 | Yes | Yes | 346.02 | 1.00 | 84.45 | 20.64 | 10.7639 | 16.59 | 6.7800 |
PERIMETER_ZN_2 | 67.30 | Yes | Yes | 205.26 | 1.00 | 56.30 | 11.16 | 10.7639 | 16.59 | 6.7800 |
PERIMETER_ZN_3 | 113.45 | Yes | Yes | 346.02 | 1.00 | 84.45 | 16.73 | 10.7639 | 16.59 | 6.7800 |
PERIMETER_ZN_4 | 67.30 | Yes | Yes | 205.26 | 1.00 | 56.30 | 11.16 | 10.7639 | 16.59 | 6.7800 |
ATTIC | 567.98 | No | No | 720.19 | 1.00 | 0.00 | 0.00 | |||
Total | 511.16 | 1559.03 | 281.51 | 59.68 | 10.7639 | 16.59 | 6.7800 | |||
Conditioned Total | 511.16 | 1559.03 | 281.51 | 59.68 | 10.7639 | 16.59 | 6.7800 | |||
Unconditioned Total | 567.98 | 720.19 | 0.00 | 0.00 | 0.0000 | 0.0000 | ||||
Not Part of Total | 567.98 | 720.19 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 8.70 | 0.00 | 8.70 | Wetbulb [C] | 3.80 | 340.00 |
MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 33.20 | 6.70 | 25.30 | Wetbulb [C] | 4.50 | 140.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_ZN_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 149.66 | 270.00 | 180.00 | |
PERIMETER_ZN_1_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.505 | 0.547 | 84.45 | 180.00 | 90.00 | S |
PERIMETER_ZN_1_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 113.45 | 135.00 | 180.00 | |
PERIMETER_ZN_2_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.505 | 0.547 | 56.30 | 90.00 | 90.00 | E |
PERIMETER_ZN_2_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 67.30 | 270.00 | 180.00 | |
PERIMETER_ZN_3_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.505 | 0.547 | 84.45 | 0.00 | 90.00 | N |
PERIMETER_ZN_3_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 113.45 | 180.00 | 180.00 | |
PERIMETER_ZN_4_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.505 | 0.547 | 56.30 | 270.00 | 90.00 | W |
PERIMETER_ZN_4_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 67.30 | 90.00 | 180.00 | |
ATTIC_SOFFIT_WEST | EXT_SOFFIT_FLOOR | 0.30 | 2.663 | 7.547 | 11.44 | 270.00 | 180.00 | |
ATTIC_SOFFIT_SOUTH | EXT_SOFFIT_FLOOR | 0.30 | 2.663 | 7.547 | 16.97 | 225.00 | 180.00 | |
ATTIC_SOFFIT_EAST | EXT_SOFFIT_FLOOR | 0.30 | 2.663 | 7.547 | 11.44 | 45.00 | 180.00 | |
ATTIC_SOFFIT_NORTH | EXT_SOFFIT_FLOOR | 0.30 | 2.663 | 7.547 | 16.97 | 315.00 | 180.00 | |
ATTIC_ROOF_NORTH | ATTICROOFDECK | 0.30 | 2.494 | 4.706 | 197.51 | 0.00 | 18.45 | |
ATTIC_ROOF_WEST | ATTICROOFDECK | 0.30 | 2.494 | 4.706 | 101.87 | 270.00 | 18.45 | |
ATTIC_ROOF_EAST | ATTICROOFDECK | 0.30 | 2.494 | 4.706 | 101.87 | 90.00 | 18.45 | |
ATTIC_ROOF_SOUTH | ATTICROOFDECK | 0.30 | 2.494 | 4.706 | 197.51 | 180.00 | 18.45 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_1_WALL_SOUTH_DOOR | WINDOW_U_1.08_SHGC_0.25 | 3.91 | 0.00 | 0.00 | 3.91 | 3.91 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_2_WALL_EAST | 90.00 | 90.00 | E | ||
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_2_WALL_EAST | 90.00 | 90.00 | E | ||
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_2_WALL_EAST | 90.00 | 90.00 | E | ||
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_2_WALL_EAST | 90.00 | 90.00 | E | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | ||
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_4_WALL_WEST | 270.00 | 90.00 | W | ||
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_4_WALL_WEST | 270.00 | 90.00 | W | ||
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_4_WALL_WEST | 270.00 | 90.00 | W | ||
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 | WINDOW_U_1.08_SHGC_0.25 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 5.778 | 0.306 | 0.155 | No | PERIMETER_ZN_4_WALL_WEST | 270.00 | 90.00 | W | ||
Total or Average | 59.68 | 5.778 | 0.306 | 0.155 | ||||||||||||
North Total or Average | 16.73 | 5.778 | 0.306 | 0.155 | ||||||||||||
Non-North Total or Average | 42.95 | 5.778 | 0.306 | 0.155 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7043.95 | 5017.49 | 2026.45 | 0.71 | 3.91 | |||
PSZ-AC:2 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7229.24 | 5349.25 | 1879.99 | 0.74 | 3.91 | |||
PSZ-AC:3 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5545.26 | 4318.69 | 1226.57 | 0.78 | 3.91 | |||
PSZ-AC:4 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7032.88 | 5182.67 | 1850.20 | 0.74 | 3.91 | |||
PSZ-AC:5 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6459.39 | 5054.36 | 1405.02 | 0.78 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6787.7 | 3.31 | 11.28 | 11.83 | 11.35 |
PSZ-AC:2 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6940.9 | 3.25 | 11.11 | 11.64 | 11.09 |
PSZ-AC:3 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5296.7 | 3.18 | 10.87 | 11.38 | 10.73 |
PSZ-AC:4 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6755.1 | 3.26 | 11.12 | 11.66 | 11.11 |
PSZ-AC:5 HEAT PUMP DX COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6166.8 | 3.18 | 10.84 | 11.35 | 10.69 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
PSZ-AC:1 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7304.3 | 4033.8 | 7.34 | 4 |
PSZ-AC:2 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7521.8 | 4165.3 | 7.32 | 4 |
PSZ-AC:3 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 5797.0 | 3222.4 | 7.30 | 4 |
PSZ-AC:4 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7314.8 | 4049.5 | 7.30 | 4 |
PSZ-AC:5 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 6755.7 | 3756.6 | 7.29 | 4 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC:1 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7043.95 | 3.29 | |
PSZ-AC:1 HEAT PUMP DX SUPP HEATING COIL | Coil:Heating:Gas | 2444.41 | 0.80 | |
PSZ-AC:2 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7229.24 | 3.29 | |
PSZ-AC:2 HEAT PUMP DX SUPP HEATING COIL | Coil:Heating:Gas | 2717.93 | 0.80 | |
PSZ-AC:3 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 5545.26 | 3.29 | |
PSZ-AC:3 HEAT PUMP DX SUPP HEATING COIL | Coil:Heating:Gas | 1646.62 | 0.80 | |
PSZ-AC:4 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 7032.88 | 3.29 | |
PSZ-AC:4 HEAT PUMP DX SUPP HEATING COIL | Coil:Heating:Gas | 2579.71 | 0.80 | |
PSZ-AC:5 HEAT PUMP DX HEATING COIL | Coil:Heating:DX:SingleSpeed | 6459.39 | 3.29 | |
PSZ-AC:5 HEAT PUMP DX SUPP HEATING COIL | Coil:Heating:Gas | 1661.74 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
PSZ-AC:1 FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 377.96 | 1160.84 | 1.00 | Fan Energy |
PSZ-AC:2 FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 426.01 | 1160.84 | 1.00 | Fan Energy |
PSZ-AC:3 FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 367.88 | 1160.84 | 1.00 | Fan Energy |
PSZ-AC:4 FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 410.38 | 1160.84 | 1.00 | Fan Energy |
PSZ-AC:5 FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 433.05 | 1160.84 | 1.00 | Fan Energy |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 0.00 | 0.0000 | 0.00 | 0.00 | 0.30 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 0.99 | 0.51 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
CORE_ZN | 3693.52 | 4432.22 | 0.271 | 0.326 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 32.80 | 0.01715 |
PERIMETER_ZN_1 | 4162.86 | 4995.43 | 0.306 | 0.367 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 33.07 | 0.01715 |
PERIMETER_ZN_2 | 3595.04 | 4314.04 | 0.264 | 0.317 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:50:00 | 30.46 | 0.01715 |
PERIMETER_ZN_3 | 4010.12 | 4812.15 | 0.295 | 0.354 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 33.07 | 0.01715 |
PERIMETER_ZN_4 | 4231.87 | 5078.24 | 0.311 | 0.373 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 32.15 | 0.01715 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
CORE_ZN | 473.99 | 568.79 | 0.020 | 0.065 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 07:40:00 | 8.70 | 0.00699 |
PERIMETER_ZN_1 | 1677.14 | 2012.57 | 0.072 | 0.087 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 07:00:00 | 8.70 | 0.00699 |
PERIMETER_ZN_2 | 1023.92 | 1228.70 | 0.044 | 0.053 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 07:00:00 | 8.70 | 0.00699 |
PERIMETER_ZN_3 | 1560.26 | 1872.31 | 0.067 | 0.081 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 07:00:00 | 8.70 | 0.00699 |
PERIMETER_ZN_4 | 1036.70 | 1244.04 | 0.045 | 0.054 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 07:00:00 | 8.70 | 0.00699 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
PSZ-AC:1 | 0.33 | 0.33 | 0.06 | 0.06 |
PSZ-AC:2 | 0.37 | 0.37 | 0.09 | 0.09 |
PSZ-AC:3 | 0.32 | 0.32 | 0.05 | 0.05 |
PSZ-AC:4 | 0.35 | 0.35 | 0.08 | 0.08 |
PSZ-AC:5 | 0.37 | 0.37 | 0.05 | 0.05 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_ZN | 3106.33 | 1284.83 | 887.00 |
PERIMETER_ZN_1 | 3639.33 | 1785.83 | 1437.50 |
PERIMETER_ZN_2 | 3419.83 | 1438.50 | 1003.67 |
PERIMETER_ZN_3 | 3140.67 | 1657.83 | 1030.33 |
PERIMETER_ZN_4 | 3427.17 | 1563.17 | 1092.50 |
ATTIC | 0.00 | 0.00 | 0.00 |
Facility | 3761.33 | 2117.17 | 1500.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_ZN | 0.00 | 54.33 | 0.00 | 54.33 |
PERIMETER_ZN_1 | 0.00 | 309.50 | 0.00 | 249.33 |
PERIMETER_ZN_2 | 0.00 | 123.67 | 0.00 | 18.67 |
PERIMETER_ZN_3 | 0.00 | 34.33 | 0.00 | 25.17 |
PERIMETER_ZN_4 | 0.00 | 73.67 | 0.00 | 17.17 |
ATTIC | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.00 | 465.67 | 0.00 | 278.33 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:45:38
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
CORE_ZN DIRECT AIR | 0.325592 |
PERIMETER_ZN_1 DIRECT AIR | 0.366982 |
PERIMETER_ZN_2 DIRECT AIR | 0.316906 |
PERIMETER_ZN_3 DIRECT AIR | 0.353517 |
PERIMETER_ZN_4 DIRECT AIR | 0.373048 |
Maximum Flow Rate [m3/s] | |
PSZ-AC:1 AIR LOOP MAIN BRANCH | 0.325592 |
PSZ-AC:2 AIR LOOP MAIN BRANCH | 0.366982 |
PSZ-AC:3 AIR LOOP MAIN BRANCH | 0.316906 |
PSZ-AC:4 AIR LOOP MAIN BRANCH | 0.353517 |
PSZ-AC:5 AIR LOOP MAIN BRANCH | 0.373048 |
Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 0.325592 |
PSZ-AC:2 | 0.366982 |
PSZ-AC:3 | 0.316906 |
PSZ-AC:4 | 0.353517 |
PSZ-AC:5 | 0.373048 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 0.325592 | 0.064618 |
PSZ-AC:2_OA_CONTROLLER | 0.366982 | 0.048985 |
PSZ-AC:3_OA_CONTROLLER | 0.316906 | 0.029058 |
PSZ-AC:4_OA_CONTROLLER | 0.353517 | 0.048985 |
PSZ-AC:5_OA_CONTROLLER | 0.373048 | 0.029058 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
PSZ-AC:1 HEAT PUMP DX COOLING COIL | 0.325592 | 7043.95 | 0.712313 |
PSZ-AC:2 HEAT PUMP DX COOLING COIL | 0.366982 | 7229.24 | 0.739947 |
PSZ-AC:3 HEAT PUMP DX COOLING COIL | 0.316906 | 5545.26 | 0.778808 |
PSZ-AC:4 HEAT PUMP DX COOLING COIL | 0.353517 | 7032.88 | 0.736921 |
PSZ-AC:5 HEAT PUMP DX COOLING COIL | 0.373048 | 6459.39 | 0.782483 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Maximum Supply Air Temperature from Supplemental Heater [C] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_HEATPUMP | 0.325592 | 0.325592 | 0.325592 | 0.325592 | 7043.95 | 7043.95 | 40.00 | 2444.41 | 1.00 |
PSZ-AC:2_HEATPUMP | 0.366982 | 0.366982 | 0.366982 | 0.366982 | 7229.24 | 7229.24 | 40.00 | 2717.93 | 1.00 |
PSZ-AC:3_HEATPUMP | 0.316906 | 0.316906 | 0.316906 | 0.316906 | 5545.26 | 5545.26 | 40.00 | 1646.62 | 1.00 |
PSZ-AC:4_HEATPUMP | 0.353517 | 0.353517 | 0.353517 | 0.353517 | 7032.88 | 7032.88 | 40.00 | 2579.71 | 1.00 |
PSZ-AC:5_HEATPUMP | 0.373048 | 0.373048 | 0.373048 | 0.373048 | 6459.39 | 6459.39 | 40.00 | 1661.74 | 1.00 |
Maximum Flow Rate [m3/s] | |
PSZ-AC:1 FAN | 0.325592 |
PSZ-AC:2 FAN | 0.366982 |
PSZ-AC:3 FAN | 0.316906 |
PSZ-AC:4 FAN | 0.353517 |
PSZ-AC:5 FAN | 0.373048 |
Rated Air Flow Rate [m3/s] | Rated Total Heating Capacity [W] | Resistive Defrost Heater Capacity | |
PSZ-AC:1 HEAT PUMP DX HEATING COIL | 0.325592 | 7043.95 | 0.000000 |
PSZ-AC:2 HEAT PUMP DX HEATING COIL | 0.366982 | 7229.24 | 0.000000 |
PSZ-AC:3 HEAT PUMP DX HEATING COIL | 0.316906 | 5545.26 | 0.000000 |
PSZ-AC:4 HEAT PUMP DX HEATING COIL | 0.353517 | 7032.88 | 0.000000 |
PSZ-AC:5 HEAT PUMP DX HEATING COIL | 0.373048 | 6459.39 | 0.000000 |
Nominal Capacity [W] | |
PSZ-AC:1 HEAT PUMP DX SUPP HEATING COIL | 2444.41 |
PSZ-AC:2 HEAT PUMP DX SUPP HEATING COIL | 2717.93 |
PSZ-AC:3 HEAT PUMP DX SUPP HEATING COIL | 1646.62 |
PSZ-AC:4 HEAT PUMP DX SUPP HEATING COIL | 2579.71 |
PSZ-AC:5 HEAT PUMP DX SUPP HEATING COIL | 1661.74 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000004 | 0.003036 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000004 | 0.000000 |
Report: MONTHLY INDOOR TEMP
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.16 | 19.42 |
February | 24.28 | 20.87 |
March | 24.45 | 21.57 |
April | 24.80 | 24.11 |
May | 25.00 | 26.41 |
June | 25.82 | 27.68 |
July | 26.29 | 28.13 |
August | 25.97 | 27.97 |
September | 26.18 | 27.49 |
October | 25.24 | 26.35 |
November | 24.65 | 23.59 |
December | 24.35 | 20.30 |
Annual Sum or Average | 25.10 | 24.51 |
Minimum of Months | 24.16 | 19.42 |
Maximum of Months | 26.29 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.87 | 19.42 |
February | 24.03 | 20.87 |
March | 24.10 | 21.57 |
April | 24.51 | 24.11 |
May | 24.92 | 26.41 |
June | 25.76 | 27.68 |
July | 26.23 | 28.13 |
August | 25.86 | 27.97 |
September | 26.22 | 27.49 |
October | 25.49 | 26.35 |
November | 24.64 | 23.59 |
December | 24.17 | 20.30 |
Annual Sum or Average | 24.99 | 24.51 |
Minimum of Months | 23.87 | 19.42 |
Maximum of Months | 26.23 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 19.42 |
February | 23.69 | 20.87 |
March | 24.05 | 21.57 |
April | 24.72 | 24.11 |
May | 25.10 | 26.41 |
June | 25.94 | 27.68 |
July | 26.38 | 28.13 |
August | 25.94 | 27.97 |
September | 26.20 | 27.49 |
October | 25.22 | 26.35 |
November | 24.28 | 23.59 |
December | 23.69 | 20.30 |
Annual Sum or Average | 24.90 | 24.51 |
Minimum of Months | 23.50 | 19.42 |
Maximum of Months | 26.38 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.23 | 19.42 |
February | 23.43 | 20.87 |
March | 23.85 | 21.57 |
April | 24.46 | 24.11 |
May | 24.92 | 26.41 |
June | 25.76 | 27.68 |
July | 26.19 | 28.13 |
August | 25.81 | 27.97 |
September | 25.97 | 27.49 |
October | 24.95 | 26.35 |
November | 24.10 | 23.59 |
December | 23.52 | 20.30 |
Annual Sum or Average | 24.69 | 24.51 |
Minimum of Months | 23.23 | 19.42 |
Maximum of Months | 26.19 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 19.42 |
February | 23.79 | 20.87 |
March | 24.26 | 21.57 |
April | 24.97 | 24.11 |
May | 25.27 | 26.41 |
June | 25.97 | 27.68 |
July | 26.43 | 28.13 |
August | 26.06 | 27.97 |
September | 26.22 | 27.49 |
October | 25.32 | 26.35 |
November | 24.35 | 23.59 |
December | 23.84 | 20.30 |
Annual Sum or Average | 25.00 | 24.51 |
Minimum of Months | 23.50 | 19.42 |
Maximum of Months | 26.43 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.59 | 19.42 |
February | 23.98 | 20.87 |
March | 25.95 | 21.57 |
April | 29.45 | 24.11 |
May | 31.81 | 26.41 |
June | 32.92 | 27.68 |
July | 33.89 | 28.13 |
August | 32.30 | 27.97 |
September | 31.86 | 27.49 |
October | 29.26 | 26.35 |
November | 25.95 | 23.59 |
December | 22.62 | 20.30 |
Annual Sum or Average | 28.48 | 24.51 |
Minimum of Months | 21.59 | 19.42 |
Maximum of Months | 33.89 | 28.13 |
Report: OUTDOOR AIR SUMMARY
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR {FOR HOURS SHOWN} [ach] | ZONE INFILTRATION AIR CHANGE RATE [Invalid/Undefined] | |
January | 357.000 | 5.127 | 0.398 | 0.000 |
February | 323.000 | 5.127 | 0.398 | 0.000 |
March | 391.000 | 5.127 | 0.398 | 0.000 |
April | 340.000 | 5.127 | 0.399 | 0.000 |
May | 374.000 | 5.127 | 0.400 | 0.000 |
June | 374.000 | 5.127 | 0.400 | 0.000 |
July | 340.000 | 5.127 | 0.400 | 0.000 |
August | 391.000 | 5.127 | 0.400 | 0.000 |
September | 340.000 | 5.127 | 0.401 | 0.000 |
October | 357.000 | 5.127 | 0.401 | 0.000 |
November | 357.000 | 5.127 | 0.400 | 0.000 |
December | 340.000 | 5.127 | 0.398 | 0.000 |
Annual Sum or Average | 4284.000 | 5.127 | 0.399 | 0.000 |
Minimum of Months | 323.000 | 5.127 | 0.398 | 0.000 |
Maximum of Months | 391.000 | 5.127 | 0.401 | 0.000 |
Report: OUTDOOR AIR SUMMARY
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR {FOR HOURS SHOWN} [ach] | ZONE INFILTRATION AIR CHANGE RATE {FOR HOURS SHOWN} [ach] | |
January | 357.000 | 3.886 | 0.397 | 0.434 |
February | 323.000 | 3.886 | 0.398 | 0.483 |
March | 391.000 | 3.886 | 0.398 | 0.481 |
April | 340.000 | 3.886 | 0.399 | 0.458 |
May | 374.000 | 3.886 | 0.400 | 0.471 |
June | 374.000 | 3.886 | 0.401 | 0.440 |
July | 340.000 | 3.886 | 0.401 | 0.411 |
August | 391.000 | 3.886 | 0.401 | 0.429 |
September | 340.000 | 3.886 | 0.402 | 0.431 |
October | 357.000 | 3.886 | 0.402 | 0.440 |
November | 357.000 | 3.886 | 0.400 | 0.448 |
December | 340.000 | 3.886 | 0.397 | 0.442 |
Annual Sum or Average | 4284.000 | 3.886 | 0.399 | 0.448 |
Minimum of Months | 323.000 | 3.886 | 0.397 | 0.411 |
Maximum of Months | 391.000 | 3.886 | 0.402 | 0.483 |
Report: OUTDOOR AIR SUMMARY
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR {FOR HOURS SHOWN} [ach] | ZONE INFILTRATION AIR CHANGE RATE {FOR HOURS SHOWN} [ach] | |
January | 357.000 | 2.305 | 0.398 | 0.087 |
February | 323.000 | 2.305 | 0.398 | 0.145 |
March | 391.000 | 2.305 | 0.398 | 0.142 |
April | 340.000 | 2.305 | 0.398 | 0.120 |
May | 374.000 | 2.305 | 0.400 | 0.138 |
June | 374.000 | 2.305 | 0.400 | 0.103 |
July | 340.000 | 2.305 | 0.400 | 0.072 |
August | 391.000 | 2.305 | 0.400 | 0.092 |
September | 340.000 | 2.305 | 0.401 | 0.092 |
October | 357.000 | 2.305 | 0.401 | 0.101 |
November | 357.000 | 2.305 | 0.399 | 0.108 |
December | 340.000 | 2.305 | 0.398 | 0.096 |
Annual Sum or Average | 4284.000 | 2.305 | 0.399 | 0.108 |
Minimum of Months | 323.000 | 2.305 | 0.398 | 0.072 |
Maximum of Months | 391.000 | 2.305 | 0.401 | 0.145 |
Report: OUTDOOR AIR SUMMARY
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR {FOR HOURS SHOWN} [ach] | ZONE INFILTRATION AIR CHANGE RATE {FOR HOURS SHOWN} [ach] | |
January | 357.000 | 3.886 | 0.397 | 0.077 |
February | 323.000 | 3.886 | 0.398 | 0.129 |
March | 391.000 | 3.886 | 0.398 | 0.126 |
April | 340.000 | 3.886 | 0.399 | 0.107 |
May | 374.000 | 3.886 | 0.400 | 0.122 |
June | 374.000 | 3.886 | 0.400 | 0.092 |
July | 340.000 | 3.886 | 0.400 | 0.064 |
August | 391.000 | 3.886 | 0.400 | 0.082 |
September | 340.000 | 3.886 | 0.401 | 0.082 |
October | 357.000 | 3.886 | 0.401 | 0.090 |
November | 357.000 | 3.886 | 0.399 | 0.096 |
December | 340.000 | 3.886 | 0.398 | 0.085 |
Annual Sum or Average | 4284.000 | 3.886 | 0.399 | 0.096 |
Minimum of Months | 323.000 | 3.886 | 0.397 | 0.064 |
Maximum of Months | 391.000 | 3.886 | 0.401 | 0.129 |
Report: OUTDOOR AIR SUMMARY
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR {FOR HOURS SHOWN} [ach] | ZONE INFILTRATION AIR CHANGE RATE {FOR HOURS SHOWN} [ach] | |
January | 357.000 | 2.305 | 0.398 | 0.087 |
February | 323.000 | 2.305 | 0.398 | 0.145 |
March | 391.000 | 2.305 | 0.398 | 0.142 |
April | 340.000 | 2.305 | 0.399 | 0.120 |
May | 374.000 | 2.305 | 0.400 | 0.138 |
June | 374.000 | 2.305 | 0.400 | 0.103 |
July | 340.000 | 2.305 | 0.400 | 0.072 |
August | 391.000 | 2.305 | 0.400 | 0.092 |
September | 340.000 | 2.305 | 0.401 | 0.092 |
October | 357.000 | 2.305 | 0.401 | 0.101 |
November | 357.000 | 2.305 | 0.399 | 0.108 |
December | 340.000 | 2.305 | 0.398 | 0.096 |
Annual Sum or Average | 4284.000 | 2.305 | 0.399 | 0.108 |
Minimum of Months | 323.000 | 2.305 | 0.398 | 0.072 |
Maximum of Months | 391.000 | 2.305 | 0.401 | 0.145 |
Report: OUTDOOR AIR SUMMARY
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE OCCUPANT COUNT [Invalid/Undefined] | ZONE PEOPLE OCCUPANT COUNT [Invalid/Undefined] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [Invalid/Undefined] | ZONE INFILTRATION AIR CHANGE RATE {FOR HOURS SHOWN} [ach] | |
January | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | 0.000 | 0.000 | |
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 | 0.000 | 0.000 |
Report: VENTILATION LOAD COMPONENTS
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | |
January | 0.142045E+09 | 0.166349E+09 | 0.000 | 3581612.546 | 9239993.432 | 0.000 | 0.325427E+09 | 0.000 |
February | 0.536819E+08 | 0.217506E+09 | 0.000 | 2553637.735 | 9042292.601 | 0.000 | 0.151474E+09 | 0.000 |
March | 0.905540E+08 | 0.343944E+09 | 0.000 | 2861952.382 | 0.205387E+08 | 0.000 | 0.225252E+09 | 0.000 |
April | 4797132.037 | 0.493552E+09 | 0.000 | 1110584.772 | 0.292620E+08 | 0.000 | 0.502553E+08 | 0.000 |
May | 27949.340 | 0.103244E+10 | 0.000 | 92685.953 | 0.742083E+08 | 0.000 | 136996.056 | 0.000 |
June | 0.000 | 0.155486E+10 | 0.000 | 0.000 | 0.108204E+09 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.160811E+10 | 0.000 | 0.000 | 0.101706E+09 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.178401E+10 | 0.000 | 0.000 | 0.115393E+09 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.146035E+10 | 0.000 | 0.000 | 0.972047E+08 | 0.000 | 0.000 | 0.000 |
October | 59216.181 | 0.108046E+10 | 0.000 | 130985.802 | 0.692171E+08 | 0.000 | 484624.923 | 0.000 |
November | 0.364739E+08 | 0.679161E+09 | 0.000 | 1146205.955 | 0.567725E+08 | 0.000 | 0.385946E+08 | 0.000 |
December | 0.104788E+09 | 0.193720E+09 | 0.000 | 3183603.757 | 0.128568E+08 | 0.000 | 0.282775E+09 | 0.000 |
Annual Sum or Average | 0.432427E+09 | 0.106145E+11 | 0.000 | 0.146613E+08 | 0.703645E+09 | 0.000 | 0.107440E+10 | 0.000 |
Minimum of Months | 0.000 | 0.166349E+09 | 0.000 | 0.000 | 9042292.601 | 0.000 | 0.000 | 0.000 |
Maximum of Months | 0.142045E+09 | 0.178401E+10 | 0.000 | 3581612.546 | 0.115393E+09 | 0.000 | 0.325427E+09 | 0.000 |
Report: VENTILATION LOAD COMPONENTS
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | |
January | 0.770749E+08 | 0.175645E+09 | 0.000 | 4155845.950 | 5076564.366 | 0.228132E+08 | 0.119420E+09 | 0.000 |
February | 0.459010E+08 | 0.215721E+09 | 0.000 | 2578354.890 | 4408850.478 | 7832966.201 | 0.388786E+08 | 0.000 |
March | 0.640855E+08 | 0.275164E+09 | 0.000 | 1935888.347 | 0.115749E+08 | 0.220944E+08 | 0.683408E+08 | 0.000 |
April | 0.164391E+08 | 0.368397E+09 | 0.000 | 633995.323 | 0.164794E+08 | 0.000 | 0.159905E+08 | 0.000 |
May | 1126570.464 | 0.742718E+09 | 0.000 | 101183.284 | 0.418666E+08 | 0.000 | 939426.929 | 0.000 |
June | 0.000 | 0.106734E+10 | 0.000 | 53773.920 | 0.609093E+08 | 0.000 | 9.916 | 0.000 |
July | 0.000 | 0.110674E+10 | 0.000 | 62320.871 | 0.567793E+08 | 0.000 | 4848.194 | 0.000 |
August | 0.000 | 0.121804E+10 | 0.000 | 96851.348 | 0.648894E+08 | 0.000 | 71.668 | 0.000 |
September | 0.000 | 0.995791E+09 | 0.000 | 214853.961 | 0.538629E+08 | 0.000 | 108976.995 | 0.000 |
October | 61004.944 | 0.801322E+09 | 0.000 | 125768.582 | 0.409651E+08 | 0.000 | 911215.119 | 0.000 |
November | 0.134759E+08 | 0.562435E+09 | 0.000 | 694604.223 | 0.321267E+08 | 5886864.962 | 0.116795E+08 | 0.000 |
December | 0.644391E+08 | 0.193634E+09 | 0.000 | 3709428.269 | 6823880.235 | 0.205721E+08 | 0.107444E+09 | 0.000 |
Annual Sum or Average | 0.282603E+09 | 0.772295E+10 | 0.000 | 0.143629E+08 | 0.395763E+09 | 0.791995E+08 | 0.363717E+09 | 0.000 |
Minimum of Months | 0.000 | 0.175645E+09 | 0.000 | 53773.920 | 4408850.478 | 0.000 | 9.916 | 0.000 |
Maximum of Months | 0.770749E+08 | 0.121804E+10 | 0.000 | 4155845.950 | 0.648894E+08 | 0.228132E+08 | 0.119420E+09 | 0.000 |
Report: VENTILATION LOAD COMPONENTS
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | |
January | 0.506592E+08 | 0.948018E+08 | 0.000 | 1878594.629 | 5261751.303 | 2646312.287 | 0.968094E+08 | 0.000 |
February | 0.259824E+08 | 0.123384E+09 | 0.000 | 1411616.178 | 5103185.300 | 1306478.140 | 0.354806E+08 | 0.000 |
March | 0.269671E+08 | 0.181499E+09 | 0.000 | 1923457.404 | 0.105201E+08 | 4074057.378 | 0.703332E+08 | 0.000 |
April | 5069115.640 | 0.262990E+09 | 0.000 | 699362.100 | 0.146412E+08 | 0.000 | 0.133405E+08 | 0.000 |
May | 219387.730 | 0.505915E+09 | 0.000 | 54926.198 | 0.343028E+08 | 0.000 | 537980.012 | 0.000 |
June | 0.000 | 0.712067E+09 | 0.000 | 19504.049 | 0.494244E+08 | 0.000 | 42.753 | 0.000 |
July | 0.000 | 0.736882E+09 | 0.000 | 19656.794 | 0.460562E+08 | 0.000 | 3813.336 | 0.000 |
August | 0.000 | 0.803856E+09 | 0.000 | 42904.418 | 0.518839E+08 | 0.000 | 2484.491 | 0.000 |
September | 0.000 | 0.657670E+09 | 0.000 | 92726.353 | 0.438201E+08 | 0.000 | 4361.169 | 0.000 |
October | 22401.108 | 0.508756E+09 | 0.000 | 42406.106 | 0.328133E+08 | 0.000 | 427987.343 | 0.000 |
November | 6277674.074 | 0.338242E+09 | 0.000 | 476281.928 | 0.270507E+08 | 2130575.034 | 9390931.791 | 0.000 |
December | 0.396353E+08 | 0.104489E+09 | 0.000 | 1347267.363 | 6754005.680 | 5803303.791 | 0.878997E+08 | 0.000 |
Annual Sum or Average | 0.154833E+09 | 0.503055E+10 | 0.000 | 8008703.520 | 0.327632E+09 | 0.159607E+08 | 0.314231E+09 | 0.000 |
Minimum of Months | 0.000 | 0.948018E+08 | 0.000 | 19504.049 | 5103185.300 | 0.000 | 42.753 | 0.000 |
Maximum of Months | 0.506592E+08 | 0.803856E+09 | 0.000 | 1923457.404 | 0.518839E+08 | 5803303.791 | 0.968094E+08 | 0.000 |
Report: VENTILATION LOAD COMPONENTS
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | |
January | 0.121755E+09 | 0.144839E+09 | 0.000 | 1380537.822 | 9590780.630 | 6333064.828 | 0.128139E+09 | 0.000 |
February | 0.555636E+08 | 0.191265E+09 | 0.000 | 1208600.427 | 9495728.379 | 2273030.313 | 0.525180E+08 | 0.000 |
March | 0.856293E+08 | 0.280671E+09 | 0.000 | 1237946.848 | 0.195367E+08 | 8548636.983 | 0.780307E+08 | 0.000 |
April | 8470215.771 | 0.415854E+09 | 0.000 | 643419.958 | 0.272874E+08 | 0.000 | 0.234588E+08 | 0.000 |
May | 554054.262 | 0.831693E+09 | 0.000 | 95391.068 | 0.611070E+08 | 0.000 | 944731.178 | 0.000 |
June | 0.000 | 0.120547E+10 | 0.000 | 23458.229 | 0.871230E+08 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.124572E+10 | 0.000 | 24676.621 | 0.814532E+08 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.136648E+10 | 0.000 | 68593.305 | 0.918343E+08 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.110879E+10 | 0.000 | 161229.619 | 0.773585E+08 | 0.000 | 2127.932 | 0.000 |
October | 51003.150 | 0.829975E+09 | 0.000 | 68806.143 | 0.579942E+08 | 0.000 | 709818.837 | 0.000 |
November | 0.149217E+08 | 0.541088E+09 | 0.000 | 459163.756 | 0.475215E+08 | 3590162.767 | 0.135688E+08 | 0.000 |
December | 0.899769E+08 | 0.164500E+09 | 0.000 | 1426849.448 | 0.119442E+08 | 0.111752E+08 | 0.126121E+09 | 0.000 |
Annual Sum or Average | 0.376922E+09 | 0.832635E+10 | 0.000 | 6798673.244 | 0.582247E+09 | 0.319201E+08 | 0.423494E+09 | 0.000 |
Minimum of Months | 0.000 | 0.144839E+09 | 0.000 | 23458.229 | 9495728.379 | 0.000 | 0.000 | 0.000 |
Maximum of Months | 0.121755E+09 | 0.136648E+10 | 0.000 | 1426849.448 | 0.918343E+08 | 0.111752E+08 | 0.128139E+09 | 0.000 |
Report: VENTILATION LOAD COMPONENTS
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | |
January | 0.693067E+08 | 0.883581E+08 | 0.000 | 1461529.349 | 6047268.507 | 3572535.530 | 0.802808E+08 | 0.000 |
February | 0.323958E+08 | 0.114209E+09 | 0.000 | 1192181.323 | 6063685.325 | 1305098.472 | 0.331026E+08 | 0.000 |
March | 0.486405E+08 | 0.168364E+09 | 0.000 | 1248522.716 | 0.111954E+08 | 5030452.963 | 0.498666E+08 | 0.000 |
April | 4741555.405 | 0.245346E+09 | 0.000 | 556443.434 | 0.146399E+08 | 0.000 | 0.152073E+08 | 0.000 |
May | 183158.471 | 0.483882E+09 | 0.000 | 65010.581 | 0.349201E+08 | 0.000 | 463366.071 | 0.000 |
June | 0.000 | 0.688470E+09 | 0.000 | 25944.737 | 0.488438E+08 | 0.000 | 19059.298 | 0.000 |
July | 0.000 | 0.718949E+09 | 0.000 | 19093.680 | 0.451296E+08 | 0.000 | 1642.578 | 0.000 |
August | 0.000 | 0.789869E+09 | 0.000 | 34683.415 | 0.521396E+08 | 0.000 | 1287.974 | 0.000 |
September | 0.000 | 0.639130E+09 | 0.000 | 85713.158 | 0.444331E+08 | 0.000 | 25106.457 | 0.000 |
October | 31985.035 | 0.489523E+09 | 0.000 | 48587.132 | 0.343049E+08 | 0.000 | 370063.686 | 0.000 |
November | 9560162.175 | 0.325093E+09 | 0.000 | 359668.771 | 0.288771E+08 | 1362178.778 | 6984106.485 | 0.000 |
December | 0.487720E+08 | 0.101840E+09 | 0.000 | 1236930.589 | 7634269.023 | 6859190.073 | 0.780532E+08 | 0.000 |
Annual Sum or Average | 0.213632E+09 | 0.485303E+10 | 0.000 | 6334308.885 | 0.334229E+09 | 0.181295E+08 | 0.264375E+09 | 0.000 |
Minimum of Months | 0.000 | 0.883581E+08 | 0.000 | 19093.680 | 6047268.507 | 0.000 | 1287.974 | 0.000 |
Maximum of Months | 0.693067E+08 | 0.789869E+09 | 0.000 | 1461529.349 | 0.521396E+08 | 6859190.073 | 0.802808E+08 | 0.000 |
Report: OVERALL HVAC AIR SYSTEM LOADS
For: PSZ-AC:1
Timestamp: 2015-09-09 18:45:38
AIR SYSTEM TOTAL HEATING ENERGY [J] | AIR SYSTEM TOTAL COOLING ENERGY [J] | |
January | 0.371459E+09 | 0.211002E+10 |
February | 0.336082E+09 | 0.228256E+10 |
March | 0.406836E+09 | 0.284635E+10 |
April | 0.353770E+09 | 0.309941E+10 |
May | 0.389147E+09 | 0.417792E+10 |
June | 0.389147E+09 | 0.553021E+10 |
July | 0.353770E+09 | 0.550207E+10 |
August | 0.406836E+09 | 0.619989E+10 |
September | 0.353770E+09 | 0.525288E+10 |
October | 0.371459E+09 | 0.422170E+10 |
November | 0.371459E+09 | 0.340739E+10 |
December | 0.353770E+09 | 0.217769E+10 |
Annual Sum or Average | 0.445751E+10 | 0.468081E+11 |
Minimum of Months | 0.336082E+09 | 0.211002E+10 |
Maximum of Months | 0.406836E+09 | 0.619989E+10 |
Report: OVERALL HVAC AIR SYSTEM LOADS
For: PSZ-AC:2
Timestamp: 2015-09-09 18:45:38
AIR SYSTEM TOTAL HEATING ENERGY [J] | AIR SYSTEM TOTAL COOLING ENERGY [J] | |
January | 0.449968E+09 | 0.293707E+10 |
February | 0.391649E+09 | 0.295997E+10 |
March | 0.501391E+09 | 0.314024E+10 |
April | 0.398742E+09 | 0.295517E+10 |
May | 0.438616E+09 | 0.436207E+10 |
June | 0.438616E+09 | 0.575762E+10 |
July | 0.399448E+09 | 0.571096E+10 |
August | 0.458764E+09 | 0.639310E+10 |
September | 0.403427E+09 | 0.560424E+10 |
October | 0.421642E+09 | 0.512973E+10 |
November | 0.427118E+09 | 0.442585E+10 |
December | 0.442725E+09 | 0.293119E+10 |
Annual Sum or Average | 0.517211E+10 | 0.523072E+11 |
Minimum of Months | 0.391649E+09 | 0.293119E+10 |
Maximum of Months | 0.501391E+09 | 0.639310E+10 |
Report: OVERALL HVAC AIR SYSTEM LOADS
For: PSZ-AC:3
Timestamp: 2015-09-09 18:45:38
AIR SYSTEM TOTAL HEATING ENERGY [J] | AIR SYSTEM TOTAL COOLING ENERGY [J] | |
January | 0.363511E+09 | 0.124271E+10 |
February | 0.327717E+09 | 0.143883E+10 |
March | 0.400231E+09 | 0.192117E+10 |
April | 0.344332E+09 | 0.213154E+10 |
May | 0.378766E+09 | 0.285107E+10 |
June | 0.379998E+09 | 0.354131E+10 |
July | 0.350466E+09 | 0.354720E+10 |
August | 0.397904E+09 | 0.383217E+10 |
September | 0.345764E+09 | 0.327068E+10 |
October | 0.361549E+09 | 0.267398E+10 |
November | 0.362292E+09 | 0.207361E+10 |
December | 0.349660E+09 | 0.119887E+10 |
Annual Sum or Average | 0.436219E+10 | 0.297231E+11 |
Minimum of Months | 0.327717E+09 | 0.119887E+10 |
Maximum of Months | 0.400231E+09 | 0.383217E+10 |
Report: OVERALL HVAC AIR SYSTEM LOADS
For: PSZ-AC:4
Timestamp: 2015-09-09 18:45:38
AIR SYSTEM TOTAL HEATING ENERGY [J] | AIR SYSTEM TOTAL COOLING ENERGY [J] | |
January | 0.408964E+09 | 0.141297E+10 |
February | 0.366092E+09 | 0.173319E+10 |
March | 0.451095E+09 | 0.223507E+10 |
April | 0.384112E+09 | 0.263331E+10 |
May | 0.422523E+09 | 0.382280E+10 |
June | 0.422523E+09 | 0.501944E+10 |
July | 0.384112E+09 | 0.495297E+10 |
August | 0.441729E+09 | 0.546449E+10 |
September | 0.384112E+09 | 0.456807E+10 |
October | 0.403318E+09 | 0.355125E+10 |
November | 0.405908E+09 | 0.270237E+10 |
December | 0.395295E+09 | 0.149791E+10 |
Annual Sum or Average | 0.486978E+10 | 0.395938E+11 |
Minimum of Months | 0.366092E+09 | 0.141297E+10 |
Maximum of Months | 0.451095E+09 | 0.546449E+10 |
Report: OVERALL HVAC AIR SYSTEM LOADS
For: PSZ-AC:5
Timestamp: 2015-09-09 18:45:38
AIR SYSTEM TOTAL HEATING ENERGY [J] | AIR SYSTEM TOTAL COOLING ENERGY [J] | |
January | 0.426983E+09 | 0.122200E+10 |
February | 0.385472E+09 | 0.143029E+10 |
March | 0.469544E+09 | 0.185945E+10 |
April | 0.406273E+09 | 0.205013E+10 |
May | 0.447102E+09 | 0.278113E+10 |
June | 0.448711E+09 | 0.340695E+10 |
July | 0.414035E+09 | 0.345929E+10 |
August | 0.470783E+09 | 0.381915E+10 |
September | 0.411437E+09 | 0.320286E+10 |
October | 0.425867E+09 | 0.261143E+10 |
November | 0.426218E+09 | 0.207690E+10 |
December | 0.409837E+09 | 0.128458E+10 |
Annual Sum or Average | 0.514226E+10 | 0.292042E+11 |
Minimum of Months | 0.385472E+09 | 0.122200E+10 |
Maximum of Months | 0.470783E+09 | 0.381915E+10 |
Report: OVERALL HVAC SYSTEM ENERGY
For: Meter
Timestamp: 2015-09-09 18:45:38
ELECTRICITY:HVAC [J] | HEATING:GAS [J] | |
January | 0.405486E+10 | 0.000 |
February | 0.410114E+10 | 0.000 |
March | 0.498171E+10 | 0.000 |
April | 0.493660E+10 | 0.000 |
May | 0.638337E+10 | 0.000 |
June | 0.752082E+10 | 0.000 |
July | 0.738353E+10 | 0.000 |
August | 0.823323E+10 | 0.000 |
September | 0.702770E+10 | 0.000 |
October | 0.627127E+10 | 0.000 |
November | 0.540663E+10 | 0.000 |
December | 0.400639E+10 | 0.000 |
Annual Sum or Average | 0.703072E+11 | 0.000 |
Minimum of Months | 0.400639E+10 | 0.000 |
Maximum of Months | 0.823323E+10 | 0.000 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:45:38
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.175079E+11 | 16725.198 | 02-JAN-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5593.670 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
February | 0.162049E+11 | 16065.812 | 10-FEB-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
March | 0.188674E+11 | 16716.528 | 13-MAR-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5585.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
April | 0.176537E+11 | 17235.552 | 14-APR-14:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6104.023 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
May | 0.198381E+11 | 17622.463 | 22-MAY-13:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6490.934 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
June | 0.207138E+11 | 18262.315 | 08-JUN-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7130.786 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
July | 0.202444E+11 | 19194.026 | 28-JUL-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
August | 0.220116E+11 | 18772.807 | 21-AUG-15:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7641.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
September | 0.197881E+11 | 18605.406 | 18-SEP-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7473.877 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
October | 0.196299E+11 | 17931.181 | 03-OCT-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6799.652 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
November | 0.185974E+11 | 17187.471 | 03-NOV-13:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6055.942 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
December | 0.171881E+11 | 16628.458 | 08-DEC-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5496.929 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.228245E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
Minimum of Months | 0.162049E+11 | 16065.812 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.220116E+11 | 19194.026 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK NET ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:45:38
ELECTRICITYNET:FACILITY [J] | ELECTRICITYNET:FACILITY {Maximum}[W] | ELECTRICITYNET:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.175079E+11 | 16725.198 | 02-JAN-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5593.670 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
February | 0.162049E+11 | 16065.812 | 10-FEB-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
March | 0.188674E+11 | 16716.528 | 13-MAR-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5585.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
April | 0.176537E+11 | 17235.552 | 14-APR-14:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6104.023 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
May | 0.198381E+11 | 17622.463 | 22-MAY-13:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6490.934 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
June | 0.207138E+11 | 18262.315 | 08-JUN-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7130.786 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
July | 0.202444E+11 | 19194.026 | 28-JUL-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
August | 0.220116E+11 | 18772.807 | 21-AUG-15:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7641.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
September | 0.197881E+11 | 18605.406 | 18-SEP-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7473.877 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
October | 0.196299E+11 | 17931.181 | 03-OCT-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6799.652 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
November | 0.185974E+11 | 17187.471 | 03-NOV-13:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6055.942 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
December | 0.171881E+11 | 16628.458 | 08-DEC-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5496.929 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.228245E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
Minimum of Months | 0.162049E+11 | 16065.812 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.220116E+11 | 19194.026 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.15 | 0.83 | 24.15 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 24.22 | 1.50 | 24.22 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 24.33 | 3.67 | 24.33 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.17 | 24.90 | 9.17 | 24.90 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 10.83 | 25.04 | 10.83 | 25.04 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 24.96 | 12.83 | 24.96 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 25.14 | 8.33 | 25.14 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 24.49 | 4.17 | 24.49 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.25 | 2.17 | 24.25 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.18 | 0.83 | 24.18 |
Annual Sum or Average | 0.00 | 0.00 | 54.33 | 24.84 | 54.33 | 24.84 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 25.14 | 12.83 | 25.14 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 26.28 | 3.67 | 24.52 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 29.81 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.20 | 0.50 | 24.20 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.50 | 24.38 | 11.50 | 24.38 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 51.17 | 25.22 | 43.00 | 24.35 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 39.83 | 25.03 | 35.17 | 24.41 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 85.17 | 25.66 | 66.17 | 24.48 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 56.83 | 25.72 | 43.50 | 24.46 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 38.50 | 24.82 | 36.33 | 24.52 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 16.33 | 26.63 | 9.50 | 24.32 |
Annual Sum or Average | 0.00 | 0.00 | 309.50 | 25.48 | 249.33 | 24.44 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 85.17 | 29.81 | 66.17 | 24.52 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.12 | 0.33 | 24.12 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.11 | 0.33 | 24.11 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.25 | 0.17 | 24.25 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 19.67 | 28.69 | 4.17 | 24.47 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 49.83 | 29.39 | 4.00 | 24.57 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 24.83 | 28.80 | 4.67 | 24.58 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 27.67 | 28.99 | 4.17 | 24.53 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.30 | 0.83 | 24.30 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 123.67 | 29.00 | 18.67 | 24.51 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 49.83 | 29.39 | 4.67 | 24.58 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.19 | 0.50 | 24.19 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 24.58 | 5.50 | 24.58 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 27.16 | 6.17 | 24.65 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 9.83 | 26.42 | 6.50 | 24.71 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 24.67 | 5.50 | 24.67 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.37 | 0.83 | 24.37 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.10 | 0.17 | 24.10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 34.33 | 26.01 | 25.17 | 24.63 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 27.16 | 6.50 | 24.71 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.12 | 0.17 | 24.12 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.11 | 0.33 | 24.11 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.11 | 0.17 | 24.11 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 29.81 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 29.23 | 0.33 | 24.18 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.83 | 28.05 | 3.67 | 24.44 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 19.83 | 28.94 | 3.67 | 24.52 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 13.33 | 28.34 | 4.00 | 24.58 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 17.00 | 28.63 | 4.00 | 24.44 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.58 | 0.83 | 24.28 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 73.67 | 28.64 | 17.17 | 24.46 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 19.83 | 29.81 | 4.00 | 24.58 |
Report: SETPOINTS NOT MET WITH TEMPERATURES
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: COMFORT REPORT - SIMPLE 55
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 159.67 | 23.95 | 96.33 | 24.28 | 34.17 | 24.41 |
February | 89.83 | 24.05 | 116.83 | 24.36 | 29.33 | 24.48 |
March | 125.83 | 24.11 | 175.67 | 24.43 | 42.83 | 24.65 |
April | 54.83 | 24.65 | 219.17 | 24.47 | 39.00 | 24.97 |
May | 99.83 | 25.14 | 347.67 | 24.38 | 99.83 | 25.14 |
June | 105.67 | 26.12 | 374.00 | 24.60 | 105.67 | 26.12 |
July | 93.83 | 26.44 | 340.00 | 24.70 | 93.83 | 26.44 |
August | 112.67 | 26.39 | 391.00 | 24.68 | 112.67 | 26.39 |
September | 92.67 | 26.37 | 340.00 | 24.65 | 92.67 | 26.37 |
October | 100.00 | 25.11 | 335.33 | 24.39 | 100.00 | 25.11 |
November | 115.83 | 24.59 | 274.00 | 24.31 | 99.83 | 24.73 |
December | 134.17 | 24.00 | 96.33 | 24.32 | 37.17 | 24.51 |
Annual Sum or Average | 1284.83 | 25.00 | 3106.33 | 24.51 | 887.00 | 25.52 |
Minimum of Months | 54.83 | 23.95 | 96.33 | 24.28 | 29.33 | 24.41 |
Maximum of Months | 159.67 | 26.44 | 391.00 | 24.70 | 112.67 | 26.44 |
Report: COMFORT REPORT - SIMPLE 55
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 139.00 | 23.33 | 203.00 | 24.10 | 47.17 | 24.19 |
February | 102.67 | 23.57 | 227.50 | 24.14 | 50.00 | 24.23 |
March | 145.83 | 23.80 | 262.50 | 24.27 | 73.50 | 24.46 |
April | 96.17 | 24.39 | 268.83 | 24.37 | 71.33 | 24.65 |
May | 161.67 | 24.98 | 369.33 | 24.46 | 161.67 | 24.98 |
June | 182.83 | 25.57 | 374.00 | 24.72 | 182.83 | 25.57 |
July | 166.17 | 25.81 | 340.00 | 24.87 | 166.17 | 25.81 |
August | 194.83 | 25.69 | 391.00 | 24.82 | 194.83 | 25.69 |
September | 162.33 | 25.73 | 340.00 | 24.88 | 162.33 | 25.73 |
October | 153.83 | 25.06 | 349.67 | 24.60 | 153.83 | 25.06 |
November | 143.50 | 24.62 | 325.17 | 24.42 | 128.83 | 24.82 |
December | 137.00 | 23.51 | 188.33 | 24.14 | 45.00 | 24.37 |
Annual Sum or Average | 1785.83 | 24.79 | 3639.33 | 24.54 | 1437.50 | 25.21 |
Minimum of Months | 96.17 | 23.33 | 188.33 | 24.10 | 45.00 | 24.19 |
Maximum of Months | 194.83 | 25.81 | 391.00 | 24.88 | 194.83 | 25.81 |
Report: COMFORT REPORT - SIMPLE 55
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 160.50 | 23.41 | 116.50 | 24.08 | 33.17 | 23.95 |
February | 95.00 | 23.58 | 181.33 | 24.11 | 34.33 | 24.10 |
March | 124.67 | 23.77 | 241.17 | 24.25 | 50.67 | 24.30 |
April | 58.67 | 24.51 | 288.67 | 24.37 | 43.83 | 24.76 |
May | 112.33 | 25.13 | 371.33 | 24.48 | 112.33 | 25.13 |
June | 126.67 | 26.04 | 374.00 | 24.73 | 126.67 | 26.04 |
July | 114.00 | 26.41 | 340.00 | 24.82 | 114.00 | 26.41 |
August | 134.50 | 26.22 | 391.00 | 24.77 | 134.50 | 26.22 |
September | 114.50 | 26.10 | 340.00 | 24.74 | 114.50 | 26.10 |
October | 110.83 | 25.03 | 349.00 | 24.44 | 110.83 | 25.03 |
November | 114.33 | 24.48 | 298.00 | 24.29 | 94.17 | 24.72 |
December | 172.50 | 23.50 | 128.83 | 24.08 | 34.67 | 24.09 |
Annual Sum or Average | 1438.50 | 24.80 | 3419.83 | 24.51 | 1003.67 | 25.43 |
Minimum of Months | 58.67 | 23.41 | 116.50 | 24.08 | 33.17 | 23.95 |
Maximum of Months | 172.50 | 26.41 | 391.00 | 24.82 | 134.50 | 26.41 |
Report: COMFORT REPORT - SIMPLE 55
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 223.83 | 23.38 | 85.67 | 24.01 | 38.67 | 23.81 |
February | 137.67 | 23.55 | 110.00 | 24.11 | 38.50 | 24.01 |
March | 165.33 | 23.63 | 189.33 | 24.26 | 54.00 | 24.16 |
April | 72.83 | 24.32 | 239.83 | 24.42 | 46.17 | 24.62 |
May | 116.17 | 25.00 | 367.00 | 24.47 | 116.17 | 25.00 |
June | 125.50 | 26.02 | 374.00 | 24.72 | 125.50 | 26.02 |
July | 111.83 | 26.41 | 340.00 | 24.81 | 111.83 | 26.41 |
August | 128.83 | 26.21 | 391.00 | 24.76 | 128.83 | 26.21 |
September | 108.67 | 26.00 | 340.00 | 24.70 | 108.67 | 26.00 |
October | 118.33 | 24.84 | 337.83 | 24.41 | 118.33 | 24.84 |
November | 138.17 | 24.26 | 274.83 | 24.26 | 103.83 | 24.54 |
December | 210.67 | 23.46 | 91.17 | 24.07 | 39.83 | 23.99 |
Annual Sum or Average | 1657.83 | 24.56 | 3140.67 | 24.52 | 1030.33 | 25.29 |
Minimum of Months | 72.83 | 23.38 | 85.67 | 24.01 | 38.50 | 23.81 |
Maximum of Months | 223.83 | 26.41 | 391.00 | 24.81 | 128.83 | 26.41 |
Report: COMFORT REPORT - SIMPLE 55
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 175.17 | 23.46 | 130.50 | 24.18 | 31.83 | 23.93 |
February | 108.17 | 23.63 | 183.67 | 24.30 | 33.50 | 24.14 |
March | 132.50 | 23.99 | 253.67 | 24.60 | 55.00 | 24.84 |
April | 80.00 | 25.56 | 272.00 | 24.82 | 60.67 | 26.11 |
May | 138.17 | 25.88 | 367.33 | 24.75 | 138.17 | 25.88 |
June | 141.33 | 26.43 | 374.00 | 24.90 | 141.33 | 26.43 |
July | 121.83 | 26.91 | 340.00 | 25.03 | 121.83 | 26.91 |
August | 141.17 | 26.80 | 391.00 | 24.99 | 141.17 | 26.80 |
September | 122.00 | 26.42 | 340.00 | 24.86 | 122.00 | 26.42 |
October | 117.67 | 25.21 | 343.17 | 24.61 | 117.67 | 25.21 |
November | 120.67 | 24.44 | 298.33 | 24.38 | 95.33 | 24.72 |
December | 164.50 | 23.53 | 133.50 | 24.21 | 34.00 | 24.12 |
Annual Sum or Average | 1563.17 | 25.12 | 3427.17 | 24.71 | 1092.50 | 25.87 |
Minimum of Months | 80.00 | 23.46 | 130.50 | 24.18 | 31.83 | 23.93 |
Maximum of Months | 175.17 | 26.91 | 391.00 | 25.03 | 141.33 | 26.91 |
Report: COMFORT REPORT - SIMPLE 55
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING LOADS - COOLING
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.139811E+10 | 4732.87 | 30-JAN-06:03 | 20.18 | 19.67 | 0.329398E+09 | 450.66 | 30-JAN-08:09 | 21.20 | 20.03 |
February | 0.136901E+10 | 4406.19 | 16-FEB-06:03 | 22.20 | 18.56 | 0.298758E+09 | 450.66 | 02-FEB-08:09 | 23.40 | 21.42 |
March | 0.172735E+10 | 4932.69 | 13-MAR-05:03 | 21.78 | 19.92 | 0.361758E+09 | 450.67 | 13-MAR-07:10 | 21.97 | 20.98 |
April | 0.170969E+10 | 5211.67 | 18-APR-05:02 | 18.30 | 14.72 | 0.315503E+09 | 450.66 | 12-APR-07:10 | 25.78 | 22.79 |
May | 0.206303E+10 | 4490.30 | 02-MAY-05:02 | 21.70 | 20.15 | 0.347506E+09 | 450.66 | 10-MAY-07:10 | 26.28 | 23.32 |
June | 0.284449E+10 | 4482.15 | 02-JUN-05:01 | 25.50 | 22.54 | 0.348972E+09 | 450.66 | 02-JUN-07:10 | 26.78 | 23.62 |
July | 0.285168E+10 | 4666.54 | 24-JUL-05:01 | 23.90 | 23.53 | 0.317801E+09 | 450.66 | 18-JUL-07:10 | 27.48 | 24.40 |
August | 0.321870E+10 | 4384.27 | 07-AUG-05:01 | 26.02 | 24.49 | 0.365338E+09 | 450.66 | 01-AUG-07:10 | 28.22 | 25.21 |
September | 0.277774E+10 | 4691.27 | 05-SEP-05:01 | 23.12 | 21.64 | 0.317537E+09 | 450.66 | 08-SEP-07:10 | 24.60 | 23.78 |
October | 0.209707E+10 | 4920.07 | 18-OCT-05:02 | 24.50 | 18.62 | 0.331788E+09 | 450.66 | 30-OCT-07:10 | 26.70 | 25.31 |
November | 0.177286E+10 | 4851.10 | 14-NOV-06:03 | 17.30 | 14.87 | 0.330867E+09 | 450.66 | 03-NOV-07:10 | 24.60 | 22.96 |
December | 0.140202E+10 | 4492.83 | 04-DEC-06:03 | 17.20 | 15.49 | 0.313858E+09 | 450.66 | 06-DEC-08:09 | 24.08 | 21.54 |
Annual Sum or Average | 0.252317E+11 | 0.397908E+10 | ||||||||
Minimum of Months | 0.136901E+10 | 4384.27 | 17.20 | 14.72 | 0.298758E+09 | 450.66 | 21.20 | 20.03 | ||
Maximum of Months | 0.321870E+10 | 5211.67 | 26.02 | 24.49 | 0.365338E+09 | 450.67 | 28.22 | 25.31 |
Report: BUILDING LOADS - COOLING
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.219964E+10 | 5614.72 | 17-JAN-14:00 | 21.70 | 15.61 | 0.247659E+09 | 375.20 | 02-JAN-14:39 | 28.90 | 23.86 |
February | 0.207532E+10 | 5720.14 | 22-FEB-14:10 | 27.30 | 14.13 | 0.225138E+09 | 341.63 | 15-FEB-08:09 | 22.38 | 19.62 |
March | 0.204758E+10 | 5131.33 | 01-MAR-14:30 | 23.85 | 15.90 | 0.272012E+09 | 341.63 | 13-MAR-07:10 | 21.97 | 20.98 |
April | 0.171812E+10 | 3979.85 | 24-APR-05:02 | 22.70 | 19.76 | 0.239037E+09 | 342.49 | 06-APR-07:10 | 22.98 | 19.57 |
May | 0.233150E+10 | 4524.03 | 22-MAY-11:45 | 33.03 | 23.01 | 0.263903E+09 | 343.19 | 22-MAY-12:09 | 33.48 | 23.07 |
June | 0.306120E+10 | 4559.03 | 29-JUN-11:10 | 30.60 | 24.63 | 0.265321E+09 | 358.91 | 26-JUN-12:09 | 30.68 | 25.16 |
July | 0.306846E+10 | 4633.08 | 31-JUL-15:22 | 30.00 | 24.33 | 0.243053E+09 | 376.65 | 31-JUL-12:09 | 32.93 | 25.12 |
August | 0.341626E+10 | 4873.58 | 30-AUG-11:05 | 31.60 | 23.13 | 0.278864E+09 | 378.74 | 31-AUG-12:09 | 31.70 | 25.02 |
September | 0.310758E+10 | 5645.29 | 30-SEP-15:53 | 31.10 | 24.58 | 0.244854E+09 | 392.84 | 29-SEP-12:09 | 30.68 | 24.16 |
October | 0.295839E+10 | 5476.85 | 19-OCT-13:40 | 27.97 | 19.84 | 0.254844E+09 | 389.46 | 03-OCT-12:09 | 31.70 | 25.10 |
November | 0.276481E+10 | 5747.52 | 06-NOV-14:10 | 27.20 | 18.37 | 0.253395E+09 | 389.16 | 10-NOV-13:30 | 28.05 | 24.04 |
December | 0.211531E+10 | 5919.86 | 04-DEC-14:30 | 25.85 | 17.99 | 0.236469E+09 | 363.00 | 08-DEC-14:09 | 27.70 | 22.73 |
Annual Sum or Average | 0.308642E+11 | 0.302455E+10 | ||||||||
Minimum of Months | 0.171812E+10 | 3979.85 | 21.70 | 14.13 | 0.225138E+09 | 341.63 | 21.97 | 19.57 | ||
Maximum of Months | 0.341626E+10 | 5919.86 | 33.03 | 24.63 | 0.278864E+09 | 392.84 | 33.48 | 25.16 |
Report: BUILDING LOADS - COOLING
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.804116E+09 | 2040.39 | 02-JAN-10:13 | 24.97 | 20.79 | 0.147336E+09 | 202.67 | 02-JAN-14:09 | 28.90 | 24.58 |
February | 0.906569E+09 | 2252.81 | 28-FEB-10:03 | 24.40 | 16.23 | 0.133867E+09 | 202.66 | 24-FEB-08:50 | 16.97 | 11.02 |
March | 0.124168E+10 | 2716.12 | 31-MAR-09:34 | 24.23 | 19.26 | 0.162298E+09 | 202.66 | 17-MAR-10:00 | 21.10 | 14.56 |
April | 0.135161E+10 | 2960.10 | 14-APR-09:23 | 27.50 | 22.92 | 0.141965E+09 | 202.66 | 03-APR-07:10 | 21.47 | 18.66 |
May | 0.167249E+10 | 3391.28 | 08-MAY-05:02 | 23.90 | 19.11 | 0.156627E+09 | 202.66 | 24-MAY-07:10 | 25.68 | 23.64 |
June | 0.208723E+10 | 3799.57 | 12-JUN-09:04 | 29.60 | 23.63 | 0.157317E+09 | 202.66 | 12-JUN-12:09 | 30.50 | 24.71 |
July | 0.212284E+10 | 4101.12 | 23-JUL-09:12 | 30.40 | 25.03 | 0.143260E+09 | 202.66 | 05-JUL-07:10 | 27.38 | 24.79 |
August | 0.225123E+10 | 3719.99 | 30-AUG-09:23 | 30.00 | 23.46 | 0.164608E+09 | 202.66 | 09-AUG-13:00 | 28.90 | 25.60 |
September | 0.195193E+10 | 3463.08 | 11-SEP-10:04 | 30.68 | 24.75 | 0.143044E+09 | 202.65 | 06-SEP-07:10 | 24.08 | 23.21 |
October | 0.151989E+10 | 3766.89 | 18-OCT-05:02 | 24.50 | 18.62 | 0.149384E+09 | 202.66 | 10-OCT-14:20 | 26.47 | 24.18 |
November | 0.118011E+10 | 3177.62 | 29-NOV-06:02 | 25.00 | 19.83 | 0.148751E+09 | 202.66 | 29-NOV-08:09 | 25.10 | 21.97 |
December | 0.736878E+09 | 2324.80 | 01-DEC-06:02 | 23.30 | 18.34 | 0.140229E+09 | 202.66 | 21-DEC-08:50 | 14.63 | 12.83 |
Annual Sum or Average | 0.178266E+11 | 0.178869E+10 | ||||||||
Minimum of Months | 0.736878E+09 | 2040.39 | 23.30 | 16.23 | 0.133867E+09 | 202.65 | 14.63 | 11.02 | ||
Maximum of Months | 0.225123E+10 | 4101.12 | 30.68 | 25.03 | 0.164608E+09 | 202.67 | 30.50 | 25.60 |
Report: BUILDING LOADS - COOLING
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.873746E+09 | 2273.56 | 02-JAN-15:00 | 28.90 | 23.36 | 0.246040E+09 | 341.78 | 10-JAN-09:50 | 18.03 | 12.78 |
February | 0.103036E+10 | 2434.55 | 17-FEB-15:00 | 26.70 | 21.26 | 0.224750E+09 | 341.63 | 28-FEB-08:20 | 20.70 | 15.84 |
March | 0.133262E+10 | 2973.95 | 14-MAR-05:02 | 23.30 | 22.15 | 0.271518E+09 | 341.63 | 03-MAR-08:09 | 22.48 | 18.09 |
April | 0.153699E+10 | 3843.70 | 24-APR-05:02 | 22.70 | 19.76 | 0.239149E+09 | 341.63 | 11-APR-07:10 | 24.18 | 20.86 |
May | 0.208375E+10 | 4381.96 | 08-MAY-05:02 | 23.90 | 19.11 | 0.263965E+09 | 341.62 | 24-MAY-07:10 | 25.68 | 23.64 |
June | 0.280305E+10 | 4013.91 | 02-JUN-13:50 | 30.60 | 24.39 | 0.265154E+09 | 341.62 | 06-JUN-07:10 | 26.38 | 24.66 |
July | 0.279798E+10 | 4321.49 | 31-JUL-14:10 | 32.85 | 25.63 | 0.241454E+09 | 341.62 | 18-JUL-07:10 | 27.48 | 24.40 |
August | 0.304304E+10 | 4217.77 | 23-AUG-14:30 | 31.95 | 25.41 | 0.277361E+09 | 341.63 | 30-AUG-07:10 | 26.57 | 23.78 |
September | 0.256691E+10 | 4178.65 | 18-SEP-13:30 | 31.10 | 24.95 | 0.240949E+09 | 341.63 | 06-SEP-07:10 | 24.08 | 23.21 |
October | 0.185422E+10 | 4689.77 | 18-OCT-05:02 | 24.50 | 18.62 | 0.251594E+09 | 341.63 | 26-OCT-07:10 | 23.68 | 22.69 |
November | 0.143411E+10 | 3981.63 | 29-NOV-06:02 | 25.00 | 19.83 | 0.250109E+09 | 342.03 | 13-NOV-09:00 | 19.40 | 13.71 |
December | 0.907742E+09 | 3810.15 | 01-DEC-06:02 | 23.30 | 18.34 | 0.234895E+09 | 341.63 | 06-DEC-08:09 | 24.08 | 21.54 |
Annual Sum or Average | 0.222645E+11 | 0.300694E+10 | ||||||||
Minimum of Months | 0.873746E+09 | 2273.56 | 22.70 | 18.34 | 0.224750E+09 | 341.62 | 18.03 | 12.78 | ||
Maximum of Months | 0.304304E+10 | 4689.77 | 32.85 | 25.63 | 0.277361E+09 | 342.03 | 27.48 | 24.66 |
Report: BUILDING LOADS - COOLING
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.739081E+09 | 2516.18 | 26-JAN-16:13 | 20.40 | 11.92 | 0.146880E+09 | 203.33 | 09-JAN-09:00 | 16.70 | 12.89 |
February | 0.858252E+09 | 3242.82 | 22-FEB-16:23 | 26.70 | 14.60 | 0.133948E+09 | 203.50 | 23-FEB-08:30 | 18.35 | 14.39 |
March | 0.111861E+10 | 3349.58 | 27-MAR-15:57 | 27.20 | 22.18 | 0.162356E+09 | 202.99 | 16-MAR-10:50 | 14.13 | 6.19 |
April | 0.121462E+10 | 3527.80 | 12-APR-15:57 | 28.90 | 23.36 | 0.142847E+09 | 202.66 | 14-APR-07:10 | 24.18 | 22.69 |
May | 0.153826E+10 | 3979.06 | 20-MAY-17:23 | 28.85 | 21.77 | 0.157409E+09 | 202.66 | 24-MAY-07:10 | 25.68 | 23.64 |
June | 0.189284E+10 | 5091.77 | 10-JUN-17:23 | 30.60 | 23.97 | 0.157864E+09 | 202.66 | 06-JUN-07:10 | 26.38 | 24.66 |
July | 0.197143E+10 | 4989.64 | 29-JUL-16:42 | 34.60 | 24.16 | 0.143851E+09 | 202.66 | 18-JUL-07:10 | 27.48 | 24.40 |
August | 0.215463E+10 | 4999.20 | 19-AUG-16:53 | 31.10 | 24.22 | 0.165304E+09 | 202.66 | 09-AUG-13:00 | 28.90 | 25.60 |
September | 0.181346E+10 | 5036.41 | 30-SEP-16:42 | 30.68 | 24.22 | 0.143385E+09 | 202.66 | 06-SEP-07:10 | 24.08 | 23.21 |
October | 0.139773E+10 | 4396.30 | 18-OCT-05:02 | 24.50 | 18.62 | 0.149817E+09 | 202.66 | 26-OCT-07:10 | 23.68 | 22.69 |
November | 0.112891E+10 | 3529.15 | 20-NOV-06:02 | 24.40 | 20.28 | 0.148790E+09 | 202.66 | 03-NOV-07:10 | 24.60 | 22.96 |
December | 0.767634E+09 | 2943.36 | 06-DEC-15:55 | 26.10 | 22.55 | 0.140025E+09 | 203.10 | 27-DEC-10:00 | 15.00 | 12.14 |
Annual Sum or Average | 0.165955E+11 | 0.179248E+10 | ||||||||
Minimum of Months | 0.739081E+09 | 2516.18 | 20.40 | 11.92 | 0.133948E+09 | 202.66 | 14.13 | 6.19 | ||
Maximum of Months | 0.215463E+10 | 5091.77 | 34.60 | 24.22 | 0.165304E+09 | 203.50 | 28.90 | 25.60 |
Report: BUILDING LOADS - COOLING
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 20.40 | 19.25 | 0.00 | 0.00 | 01-JAN-00:10 | 20.40 | 19.25 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 16.65 | 13.09 | 0.00 | 0.00 | 01-FEB-00:10 | 16.65 | 13.09 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 17.32 | 13.43 | 0.00 | 0.00 | 01-MAR-00:10 | 17.32 | 13.43 |
April | 0.00 | 0.00 | 01-APR-00:10 | 22.57 | 18.62 | 0.00 | 0.00 | 01-APR-00:10 | 22.57 | 18.62 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.05 | 20.01 | 0.00 | 0.00 | 01-MAY-00:10 | 22.05 | 20.01 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 26.68 | 24.41 | 0.00 | 0.00 | 01-JUN-00:10 | 26.68 | 24.41 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 26.83 | 23.72 | 0.00 | 0.00 | 01-JUL-00:10 | 26.83 | 23.72 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 28.60 | 25.82 | 0.00 | 0.00 | 01-AUG-00:10 | 28.60 | 25.82 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 27.05 | 23.99 | 0.00 | 0.00 | 01-SEP-00:10 | 27.05 | 23.99 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 27.93 | 23.96 | 0.00 | 0.00 | 01-OCT-00:10 | 27.93 | 23.96 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 22.40 | 21.03 | 0.00 | 0.00 | 01-NOV-00:10 | 22.40 | 21.03 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 24.10 | 21.21 | 0.00 | 0.00 | 01-DEC-00:10 | 24.10 | 21.21 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 16.65 | 13.09 | 0.00 | 0.00 | 16.65 | 13.09 | ||
Maximum of Months | 0.00 | 0.00 | 28.60 | 25.82 | 0.00 | 0.00 | 28.60 | 25.82 |
Report: BUILDING LOADS - HEATING
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 8734135.77 | 361.19 | 23-JAN-18:02 | 24.22 |
February | 12260136.72 | 413.49 | 10-FEB-18:12 | 25.03 |
March | 18791051.02 | 695.58 | 13-MAR-17:02 | 28.80 |
April | 25466223.01 | 854.04 | 17-APR-17:02 | 31.02 |
May | 41654835.25 | 909.42 | 22-MAY-17:02 | 31.52 |
June | 42533380.50 | 855.34 | 09-JUN-17:01 | 30.92 |
July | 43122638.42 | 1095.63 | 28-JUL-17:01 | 34.13 |
August | 46817129.43 | 920.92 | 07-AUG-17:02 | 31.93 |
September | 38329443.64 | 891.00 | 08-SEP-17:02 | 31.60 |
October | 35461471.72 | 807.80 | 03-OCT-17:02 | 30.40 |
November | 28845568.49 | 602.77 | 03-NOV-17:03 | 27.80 |
December | 7571366.76 | 407.51 | 08-DEC-18:12 | 25.00 |
Annual Sum or Average | 0.349587E+09 | |||
Minimum of Months | 7571366.76 | 361.19 | 24.22 | |
Maximum of Months | 46817129.43 | 1095.63 | 34.13 |
Report: BUILDING LOADS - HEATING
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 47502490.67 | 2202.12 | 25-JAN-06:03 | 9.40 |
February | 38705289.80 | 1420.52 | 03-FEB-07:10 | 10.60 |
March | 65530120.44 | 4232.44 | 16-MAR-05:03 | 6.70 |
April | 36498231.28 | 734.23 | 17-APR-17:12 | 30.93 |
May | 39215027.86 | 732.84 | 22-MAY-17:02 | 31.52 |
June | 37526134.65 | 728.25 | 09-JUN-17:11 | 30.73 |
July | 36814918.58 | 847.64 | 28-JUL-17:01 | 34.13 |
August | 41041316.03 | 770.67 | 07-AUG-17:11 | 31.67 |
September | 33574245.65 | 743.95 | 08-SEP-17:11 | 31.50 |
October | 31955714.50 | 678.40 | 03-OCT-17:12 | 30.20 |
November | 39411258.24 | 1436.68 | 13-NOV-06:05 | 12.20 |
December | 55167168.32 | 4095.56 | 15-DEC-06:03 | 7.80 |
Annual Sum or Average | 0.502942E+09 | |||
Minimum of Months | 31955714.50 | 678.40 | 6.70 | |
Maximum of Months | 65530120.44 | 4232.44 | 34.13 |
Report: BUILDING LOADS - HEATING
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 25142057.49 | 1930.83 | 25-JAN-06:03 | 9.40 |
February | 26318706.06 | 358.85 | 10-FEB-18:12 | 25.03 |
March | 28215001.87 | 2651.94 | 16-MAR-05:03 | 6.70 |
April | 24672294.85 | 537.46 | 17-APR-17:12 | 30.93 |
May | 29917448.43 | 543.10 | 22-MAY-17:23 | 31.15 |
June | 29080760.06 | 536.79 | 09-JUN-17:11 | 30.73 |
July | 28220845.12 | 624.37 | 27-JUL-17:11 | 33.67 |
August | 31906958.34 | 562.87 | 07-AUG-17:11 | 31.67 |
September | 26740875.78 | 555.53 | 08-SEP-17:11 | 31.50 |
October | 27278374.83 | 519.86 | 03-OCT-17:12 | 30.20 |
November | 27170495.77 | 976.66 | 13-NOV-06:05 | 12.20 |
December | 27361072.79 | 2795.78 | 15-DEC-06:03 | 7.80 |
Annual Sum or Average | 0.332025E+09 | |||
Minimum of Months | 24672294.85 | 358.85 | 6.70 | |
Maximum of Months | 31906958.34 | 2795.78 | 33.67 |
Report: BUILDING LOADS - HEATING
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 22314809.94 | 2882.82 | 25-JAN-06:03 | 9.40 |
February | 27104162.81 | 423.23 | 10-FEB-18:12 | 25.03 |
March | 31293894.05 | 4070.52 | 16-MAR-05:03 | 6.70 |
April | 27863596.37 | 731.86 | 17-APR-17:12 | 30.93 |
May | 36956316.02 | 734.63 | 22-MAY-17:02 | 31.52 |
June | 36575639.44 | 709.77 | 09-JUN-17:11 | 30.73 |
July | 36277575.29 | 870.45 | 28-JUL-17:01 | 34.13 |
August | 40883792.94 | 769.59 | 07-AUG-17:11 | 31.67 |
September | 34194300.45 | 758.25 | 08-SEP-17:11 | 31.50 |
October | 34157000.85 | 698.87 | 03-OCT-17:12 | 30.20 |
November | 33493536.56 | 1294.69 | 13-NOV-06:05 | 12.20 |
December | 23987741.36 | 4208.36 | 15-DEC-06:03 | 7.80 |
Annual Sum or Average | 0.385102E+09 | |||
Minimum of Months | 22314809.94 | 423.23 | 6.70 | |
Maximum of Months | 40883792.94 | 4208.36 | 34.13 |
Report: BUILDING LOADS - HEATING
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 39540709.84 | 1574.25 | 25-JAN-06:03 | 9.40 |
February | 36422469.34 | 400.62 | 17-FEB-18:25 | 24.40 |
March | 30579649.49 | 2024.12 | 16-MAR-05:03 | 6.70 |
April | 21943869.96 | 561.86 | 17-APR-17:12 | 30.93 |
May | 28031530.10 | 575.84 | 22-MAY-17:23 | 31.15 |
June | 28292573.81 | 562.17 | 07-JUN-17:12 | 30.40 |
July | 25416522.67 | 643.52 | 27-JUL-17:11 | 33.67 |
August | 29881196.13 | 577.96 | 07-AUG-17:11 | 31.67 |
September | 27820147.28 | 584.84 | 08-SEP-17:11 | 31.50 |
October | 27990647.75 | 565.38 | 18-OCT-05:03 | 24.50 |
November | 32424855.68 | 1008.45 | 13-NOV-06:05 | 12.20 |
December | 36031064.88 | 2704.61 | 15-DEC-06:03 | 7.80 |
Annual Sum or Average | 0.364375E+09 | |||
Minimum of Months | 21943869.96 | 400.62 | 6.70 | |
Maximum of Months | 39540709.84 | 2704.61 | 33.67 |
Report: BUILDING LOADS - HEATING
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 20.40 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 16.65 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 17.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 22.57 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.05 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 26.68 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 26.83 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 28.60 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 27.05 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 27.93 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 22.40 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 24.10 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 16.65 | |
Maximum of Months | 0.00 | 0.00 | 28.60 |
Report: BUILDING LOADS - ELECTRIC
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.178023E+10 | 1486.92 | 02-JAN-08:09 | 0.129836E+10 | 1014.68 | 02-JAN-08:09 |
February | 0.160950E+10 | 1486.92 | 01-FEB-08:09 | 0.117388E+10 | 1014.68 | 01-FEB-08:09 |
March | 0.187582E+10 | 1486.92 | 01-MAR-08:09 | 0.137025E+10 | 1014.68 | 01-MAR-08:09 |
April | 0.170739E+10 | 1486.92 | 03-APR-07:10 | 0.124489E+10 | 1014.68 | 03-APR-07:10 |
May | 0.182803E+10 | 1486.92 | 01-MAY-07:10 | 0.133431E+10 | 1014.68 | 01-MAY-07:10 |
June | 0.180297E+10 | 1486.92 | 01-JUN-07:10 | 0.131677E+10 | 1014.68 | 01-JUN-07:10 |
July | 0.173244E+10 | 1486.92 | 03-JUL-07:10 | 0.126242E+10 | 1014.68 | 03-JUL-07:10 |
August | 0.187582E+10 | 1486.92 | 01-AUG-07:10 | 0.137025E+10 | 1014.68 | 01-AUG-07:10 |
September | 0.170739E+10 | 1486.92 | 01-SEP-07:10 | 0.124489E+10 | 1014.68 | 01-SEP-07:10 |
October | 0.178023E+10 | 1486.92 | 02-OCT-07:10 | 0.129836E+10 | 1014.68 | 02-OCT-07:10 |
November | 0.175518E+10 | 1486.92 | 01-NOV-07:10 | 0.128083E+10 | 1014.68 | 01-NOV-07:10 |
December | 0.173244E+10 | 1486.92 | 01-DEC-08:09 | 0.126242E+10 | 1014.68 | 01-DEC-08:09 |
Annual Sum or Average | 0.211874E+11 | 0.154576E+11 | ||||
Minimum of Months | 0.160950E+10 | 1486.92 | 0.117388E+10 | 1014.68 | ||
Maximum of Months | 0.187582E+10 | 1486.92 | 0.137025E+10 | 1014.68 |
Report: BUILDING LOADS - ELECTRIC
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.134953E+10 | 1127.18 | 02-JAN-08:09 | 0.984244E+09 | 769.19 | 02-JAN-08:09 |
February | 0.122010E+10 | 1127.18 | 01-FEB-08:09 | 0.889874E+09 | 769.19 | 01-FEB-08:09 |
March | 0.142199E+10 | 1127.18 | 01-MAR-08:09 | 0.103874E+10 | 769.19 | 01-MAR-08:09 |
April | 0.129431E+10 | 1127.18 | 03-APR-07:10 | 0.943705E+09 | 769.19 | 03-APR-07:10 |
May | 0.138576E+10 | 1127.18 | 01-MAY-07:10 | 0.101149E+10 | 769.19 | 01-MAY-07:10 |
June | 0.136677E+10 | 1127.18 | 01-JUN-07:10 | 0.998201E+09 | 769.19 | 01-JUN-07:10 |
July | 0.131330E+10 | 1127.18 | 03-JUL-07:10 | 0.956997E+09 | 769.19 | 03-JUL-07:10 |
August | 0.142199E+10 | 1127.18 | 01-AUG-07:10 | 0.103874E+10 | 769.19 | 01-AUG-07:10 |
September | 0.129431E+10 | 1127.18 | 01-SEP-07:10 | 0.943705E+09 | 769.19 | 01-SEP-07:10 |
October | 0.134953E+10 | 1127.18 | 02-OCT-07:10 | 0.984244E+09 | 769.19 | 02-OCT-07:10 |
November | 0.133054E+10 | 1127.18 | 01-NOV-07:10 | 0.970953E+09 | 769.19 | 01-NOV-07:10 |
December | 0.131330E+10 | 1127.18 | 01-DEC-08:09 | 0.956997E+09 | 769.19 | 01-DEC-08:09 |
Annual Sum or Average | 0.160615E+11 | 0.117179E+11 | ||||
Minimum of Months | 0.122010E+10 | 1127.18 | 0.889874E+09 | 769.19 | ||
Maximum of Months | 0.142199E+10 | 1127.18 | 0.103874E+10 | 769.19 |
Report: BUILDING LOADS - ELECTRIC
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.800560E+09 | 668.66 | 02-JAN-08:09 | 0.583867E+09 | 456.29 | 02-JAN-08:09 |
February | 0.723780E+09 | 668.66 | 01-FEB-08:09 | 0.527885E+09 | 456.29 | 01-FEB-08:09 |
March | 0.843543E+09 | 668.66 | 01-MAR-08:09 | 0.616194E+09 | 456.29 | 01-MAR-08:09 |
April | 0.767803E+09 | 668.66 | 03-APR-07:10 | 0.559818E+09 | 456.29 | 03-APR-07:10 |
May | 0.822052E+09 | 668.66 | 01-MAY-07:10 | 0.600030E+09 | 456.29 | 01-MAY-07:10 |
June | 0.810786E+09 | 668.66 | 01-JUN-07:10 | 0.592146E+09 | 456.29 | 01-JUN-07:10 |
July | 0.779069E+09 | 668.66 | 03-JUL-07:10 | 0.567703E+09 | 456.29 | 03-JUL-07:10 |
August | 0.843543E+09 | 668.66 | 01-AUG-07:10 | 0.616194E+09 | 456.29 | 01-AUG-07:10 |
September | 0.767803E+09 | 668.66 | 01-SEP-07:10 | 0.559818E+09 | 456.29 | 01-SEP-07:10 |
October | 0.800560E+09 | 668.66 | 02-OCT-07:10 | 0.583867E+09 | 456.29 | 02-OCT-07:10 |
November | 0.789294E+09 | 668.66 | 01-NOV-07:10 | 0.575982E+09 | 456.29 | 01-NOV-07:10 |
December | 0.779069E+09 | 668.66 | 01-DEC-08:09 | 0.567703E+09 | 456.29 | 01-DEC-08:09 |
Annual Sum or Average | 0.952786E+10 | 0.695120E+10 | ||||
Minimum of Months | 0.723780E+09 | 668.66 | 0.527885E+09 | 456.29 | ||
Maximum of Months | 0.843543E+09 | 668.66 | 0.616194E+09 | 456.29 |
Report: BUILDING LOADS - ELECTRIC
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.134953E+10 | 1127.18 | 02-JAN-08:09 | 0.984244E+09 | 769.19 | 02-JAN-08:09 |
February | 0.122010E+10 | 1127.18 | 01-FEB-08:09 | 0.889874E+09 | 769.19 | 01-FEB-08:09 |
March | 0.142199E+10 | 1127.18 | 01-MAR-08:09 | 0.103874E+10 | 769.19 | 01-MAR-08:09 |
April | 0.129431E+10 | 1127.18 | 03-APR-07:10 | 0.943705E+09 | 769.19 | 03-APR-07:10 |
May | 0.138576E+10 | 1127.18 | 01-MAY-07:10 | 0.101149E+10 | 769.19 | 01-MAY-07:10 |
June | 0.136677E+10 | 1127.18 | 01-JUN-07:10 | 0.998201E+09 | 769.19 | 01-JUN-07:10 |
July | 0.131330E+10 | 1127.18 | 03-JUL-07:10 | 0.956997E+09 | 769.19 | 03-JUL-07:10 |
August | 0.142199E+10 | 1127.18 | 01-AUG-07:10 | 0.103874E+10 | 769.19 | 01-AUG-07:10 |
September | 0.129431E+10 | 1127.18 | 01-SEP-07:10 | 0.943705E+09 | 769.19 | 01-SEP-07:10 |
October | 0.134953E+10 | 1127.18 | 02-OCT-07:10 | 0.984244E+09 | 769.19 | 02-OCT-07:10 |
November | 0.133054E+10 | 1127.18 | 01-NOV-07:10 | 0.970953E+09 | 769.19 | 01-NOV-07:10 |
December | 0.131330E+10 | 1127.18 | 01-DEC-08:09 | 0.956997E+09 | 769.19 | 01-DEC-08:09 |
Annual Sum or Average | 0.160615E+11 | 0.117179E+11 | ||||
Minimum of Months | 0.122010E+10 | 1127.18 | 0.889874E+09 | 769.19 | ||
Maximum of Months | 0.142199E+10 | 1127.18 | 0.103874E+10 | 769.19 |
Report: BUILDING LOADS - ELECTRIC
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.800560E+09 | 668.66 | 02-JAN-08:09 | 0.583867E+09 | 456.29 | 02-JAN-08:09 |
February | 0.723780E+09 | 668.66 | 01-FEB-08:09 | 0.527885E+09 | 456.29 | 01-FEB-08:09 |
March | 0.843543E+09 | 668.66 | 01-MAR-08:09 | 0.616194E+09 | 456.29 | 01-MAR-08:09 |
April | 0.767803E+09 | 668.66 | 03-APR-07:10 | 0.559818E+09 | 456.29 | 03-APR-07:10 |
May | 0.822052E+09 | 668.66 | 01-MAY-07:10 | 0.600030E+09 | 456.29 | 01-MAY-07:10 |
June | 0.810786E+09 | 668.66 | 01-JUN-07:10 | 0.592146E+09 | 456.29 | 01-JUN-07:10 |
July | 0.779069E+09 | 668.66 | 03-JUL-07:10 | 0.567703E+09 | 456.29 | 03-JUL-07:10 |
August | 0.843543E+09 | 668.66 | 01-AUG-07:10 | 0.616194E+09 | 456.29 | 01-AUG-07:10 |
September | 0.767803E+09 | 668.66 | 01-SEP-07:10 | 0.559818E+09 | 456.29 | 01-SEP-07:10 |
October | 0.800560E+09 | 668.66 | 02-OCT-07:10 | 0.583867E+09 | 456.29 | 02-OCT-07:10 |
November | 0.789294E+09 | 668.66 | 01-NOV-07:10 | 0.575982E+09 | 456.29 | 01-NOV-07:10 |
December | 0.779069E+09 | 668.66 | 01-DEC-08:09 | 0.567703E+09 | 456.29 | 01-DEC-08:09 |
Annual Sum or Average | 0.952786E+10 | 0.695120E+10 | ||||
Minimum of Months | 0.723780E+09 | 668.66 | 0.527885E+09 | 456.29 | ||
Maximum of Months | 0.843543E+09 | 668.66 | 0.616194E+09 | 456.29 |
Report: SPACE LOADS
For: CORE_ZN
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [Invalid/Undefined] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [Invalid/Undefined] | |
January | 0.790646E+09 | 0.178023E+10 | 0.129836E+10 | 0.00 | 0.00 |
February | 0.715347E+09 | 0.160950E+10 | 0.117388E+10 | 0.00 | 0.00 |
March | 0.865946E+09 | 0.187582E+10 | 0.137025E+10 | 0.00 | 0.00 |
April | 0.752997E+09 | 0.170739E+10 | 0.124489E+10 | 0.00 | 0.00 |
May | 0.828296E+09 | 0.182803E+10 | 0.133431E+10 | 0.00 | 0.00 |
June | 0.828296E+09 | 0.180297E+10 | 0.131677E+10 | 0.00 | 0.00 |
July | 0.752997E+09 | 0.173244E+10 | 0.126242E+10 | 0.00 | 0.00 |
August | 0.865946E+09 | 0.187582E+10 | 0.137025E+10 | 0.00 | 0.00 |
September | 0.752997E+09 | 0.170739E+10 | 0.124489E+10 | 0.00 | 0.00 |
October | 0.790646E+09 | 0.178023E+10 | 0.129836E+10 | 0.00 | 0.00 |
November | 0.790646E+09 | 0.175518E+10 | 0.128083E+10 | 0.00 | 0.00 |
December | 0.752997E+09 | 0.173244E+10 | 0.126242E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.948776E+10 | 0.211874E+11 | 0.154576E+11 | 0.00 | 0.00 |
Minimum of Months | 0.715347E+09 | 0.160950E+10 | 0.117388E+10 | 0.00 | 0.00 |
Maximum of Months | 0.865946E+09 | 0.187582E+10 | 0.137025E+10 | 0.00 | 0.00 |
Report: SPACE LOADS
For: PERIMETER_ZN_1
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.599361E+09 | 0.134953E+10 | 0.984244E+09 | 18962049.89 | 0.347613E+09 |
February | 0.542279E+09 | 0.122010E+10 | 0.889874E+09 | 40598940.95 | 0.273545E+09 |
March | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 44900265.70 | 0.293261E+09 |
April | 0.570820E+09 | 0.129431E+10 | 0.943705E+09 | 0.106741E+09 | 93081131.43 |
May | 0.627902E+09 | 0.138576E+10 | 0.101149E+10 | 0.248702E+09 | 20238897.25 |
June | 0.627902E+09 | 0.136677E+10 | 0.998201E+09 | 0.273607E+09 | 10711145.20 |
July | 0.570820E+09 | 0.131330E+10 | 0.956997E+09 | 0.291103E+09 | 15401938.52 |
August | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 0.322430E+09 | 9676667.89 |
September | 0.570820E+09 | 0.129431E+10 | 0.943705E+09 | 0.238357E+09 | 16485914.96 |
October | 0.599361E+09 | 0.134953E+10 | 0.984244E+09 | 0.191037E+09 | 26416637.56 |
November | 0.599361E+09 | 0.133054E+10 | 0.970953E+09 | 0.105359E+09 | 0.156187E+09 |
December | 0.570820E+09 | 0.131330E+10 | 0.956997E+09 | 22209767.38 | 0.334704E+09 |
Annual Sum or Average | 0.719233E+10 | 0.160615E+11 | 0.117179E+11 | 0.190401E+10 | 0.159732E+10 |
Minimum of Months | 0.542279E+09 | 0.122010E+10 | 0.889874E+09 | 18962049.89 | 9676667.89 |
Maximum of Months | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 0.322430E+09 | 0.347613E+09 |
Report: SPACE LOADS
For: PERIMETER_ZN_2
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.355549E+09 | 0.800560E+09 | 0.583867E+09 | 2288008.20 | 85219774.02 |
February | 0.321687E+09 | 0.723780E+09 | 0.527885E+09 | 5421080.68 | 0.107188E+09 |
March | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 5771774.94 | 99064847.48 |
April | 0.338618E+09 | 0.767803E+09 | 0.559818E+09 | 10139477.98 | 41469066.08 |
May | 0.372480E+09 | 0.822052E+09 | 0.600030E+09 | 33169502.48 | 11845780.10 |
June | 0.372480E+09 | 0.810786E+09 | 0.592146E+09 | 33759030.19 | 8089026.73 |
July | 0.338618E+09 | 0.779069E+09 | 0.567703E+09 | 26523853.97 | 11122608.29 |
August | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 34602768.77 | 5637167.65 |
September | 0.338618E+09 | 0.767803E+09 | 0.559818E+09 | 28797193.05 | 9978412.92 |
October | 0.355549E+09 | 0.800560E+09 | 0.583867E+09 | 24259928.47 | 9083635.01 |
November | 0.355549E+09 | 0.789294E+09 | 0.575982E+09 | 14901764.53 | 58639278.81 |
December | 0.338618E+09 | 0.779069E+09 | 0.567703E+09 | 3753137.37 | 86108716.02 |
Annual Sum or Average | 0.426659E+10 | 0.952786E+10 | 0.695120E+10 | 0.223388E+09 | 0.533446E+09 |
Minimum of Months | 0.321687E+09 | 0.723780E+09 | 0.527885E+09 | 2288008.20 | 5637167.65 |
Maximum of Months | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 34602768.77 | 0.107188E+09 |
Report: SPACE LOADS
For: PERIMETER_ZN_3
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.599361E+09 | 0.134953E+10 | 0.984244E+09 | 5787343.05 | 0.119364E+09 |
February | 0.542279E+09 | 0.122010E+10 | 0.889874E+09 | 9745160.87 | 0.150536E+09 |
March | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 10258127.80 | 0.140153E+09 |
April | 0.570820E+09 | 0.129431E+10 | 0.943705E+09 | 20848246.47 | 54937231.92 |
May | 0.627902E+09 | 0.138576E+10 | 0.101149E+10 | 56263891.43 | 14947188.16 |
June | 0.627902E+09 | 0.136677E+10 | 0.998201E+09 | 54752871.63 | 10134462.84 |
July | 0.570820E+09 | 0.131330E+10 | 0.956997E+09 | 43862349.68 | 14557333.90 |
August | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 56502125.25 | 7585781.30 |
September | 0.570820E+09 | 0.129431E+10 | 0.943705E+09 | 49898044.05 | 13161345.95 |
October | 0.599361E+09 | 0.134953E+10 | 0.984244E+09 | 45001774.41 | 11359193.84 |
November | 0.599361E+09 | 0.133054E+10 | 0.970953E+09 | 26547833.71 | 80912591.24 |
December | 0.570820E+09 | 0.131330E+10 | 0.956997E+09 | 7954722.55 | 0.124151E+09 |
Annual Sum or Average | 0.719233E+10 | 0.160615E+11 | 0.117179E+11 | 0.387422E+09 | 0.741799E+09 |
Minimum of Months | 0.542279E+09 | 0.122010E+10 | 0.889874E+09 | 5787343.05 | 7585781.30 |
Maximum of Months | 0.656443E+09 | 0.142199E+10 | 0.103874E+10 | 56502125.25 | 0.150536E+09 |
Report: SPACE LOADS
For: PERIMETER_ZN_4
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.355549E+09 | 0.800560E+09 | 0.583867E+09 | 3251663.00 | 85529492.08 |
February | 0.321687E+09 | 0.723780E+09 | 0.527885E+09 | 5191594.81 | 0.111596E+09 |
March | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 5873718.96 | 0.110306E+09 |
April | 0.338618E+09 | 0.767803E+09 | 0.559818E+09 | 11144644.24 | 53602578.94 |
May | 0.372480E+09 | 0.822052E+09 | 0.600030E+09 | 30761982.39 | 18487688.86 |
June | 0.372480E+09 | 0.810786E+09 | 0.592146E+09 | 30692861.64 | 8215482.41 |
July | 0.338618E+09 | 0.779069E+09 | 0.567703E+09 | 26241591.76 | 12092626.89 |
August | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 31740031.68 | 6920189.03 |
September | 0.338618E+09 | 0.767803E+09 | 0.559818E+09 | 27527337.88 | 10578224.62 |
October | 0.355549E+09 | 0.800560E+09 | 0.583867E+09 | 22893829.14 | 12474136.35 |
November | 0.355549E+09 | 0.789294E+09 | 0.575982E+09 | 14320036.21 | 59282275.69 |
December | 0.338618E+09 | 0.779069E+09 | 0.567703E+09 | 3904677.49 | 90444192.91 |
Annual Sum or Average | 0.426659E+10 | 0.952786E+10 | 0.695120E+10 | 0.213544E+09 | 0.579529E+09 |
Minimum of Months | 0.321687E+09 | 0.723780E+09 | 0.527885E+09 | 3251663.00 | 6920189.03 |
Maximum of Months | 0.389411E+09 | 0.843543E+09 | 0.616194E+09 | 31740031.68 | 0.111596E+09 |
Report: SPACE LOADS
For: ATTIC
Timestamp: 2015-09-09 18:45:38
ZONE PEOPLE TOTAL HEATING ENERGY [Invalid/Undefined] | ZONE LIGHTS TOTAL HEATING ENERGY [Invalid/Undefined] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [Invalid/Undefined] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.109141E+10 | 0.248802E+10 |
February | 0.00 | 0.00 | 0.00 | 0.808061E+09 | 0.261111E+10 |
March | 0.00 | 0.00 | 0.00 | 0.811567E+09 | 0.364510E+10 |
April | 0.00 | 0.00 | 0.00 | 0.797623E+09 | 0.410051E+10 |
May | 0.00 | 0.00 | 0.00 | 0.731420E+09 | 0.415185E+10 |
June | 0.00 | 0.00 | 0.00 | 0.721938E+09 | 0.393163E+10 |
July | 0.00 | 0.00 | 0.00 | 0.817554E+09 | 0.445271E+10 |
August | 0.00 | 0.00 | 0.00 | 0.870948E+09 | 0.360029E+10 |
September | 0.00 | 0.00 | 0.00 | 0.773309E+09 | 0.344336E+10 |
October | 0.00 | 0.00 | 0.00 | 0.104639E+10 | 0.288415E+10 |
November | 0.00 | 0.00 | 0.00 | 0.920918E+09 | 0.238117E+10 |
December | 0.00 | 0.00 | 0.00 | 0.867471E+09 | 0.236734E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.102586E+11 | 0.400572E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.721938E+09 | 0.236734E+10 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.109141E+10 | 0.445271E+10 |
Report: ENERGY CONSUMPTION - ELECTRICITY & NATURAL GAS
For: Meter
Timestamp: 2015-09-09 18:45:38
ELECTRICITY:BUILDING [J] | ELECTRICITY:BUILDING {Maximum}[W] | ELECTRICITY:BUILDING {TIMESTAMP} | GAS:BUILDING [Invalid/Undefined] | GAS:BUILDING [Invalid/Undefined] | |
January | 0.105150E+11 | 8544.26 | 02-JAN-08:09 | 0.00 | 0.00 |
February | 0.950665E+10 | 8544.26 | 01-FEB-08:09 | 0.00 | 0.00 |
March | 0.110870E+11 | 8544.26 | 01-MAR-08:09 | 0.00 | 0.00 |
April | 0.100836E+11 | 8544.26 | 03-APR-07:10 | 0.00 | 0.00 |
May | 0.108010E+11 | 8544.26 | 01-MAY-07:10 | 0.00 | 0.00 |
June | 0.106556E+11 | 8544.26 | 01-JUN-07:10 | 0.00 | 0.00 |
July | 0.102290E+11 | 8544.26 | 03-JUL-07:10 | 0.00 | 0.00 |
August | 0.110870E+11 | 8544.26 | 01-AUG-07:10 | 0.00 | 0.00 |
September | 0.100836E+11 | 8544.26 | 01-SEP-07:10 | 0.00 | 0.00 |
October | 0.105150E+11 | 8544.26 | 02-OCT-07:10 | 0.00 | 0.00 |
November | 0.103696E+11 | 8544.26 | 01-NOV-07:10 | 0.00 | 0.00 |
December | 0.102290E+11 | 8544.26 | 01-DEC-08:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.125162E+12 | 0.00 | 0.00 | ||
Minimum of Months | 0.950665E+10 | 8544.26 | 0.00 | 0.00 | |
Maximum of Months | 0.110870E+11 | 8544.26 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY
For: Meter
Timestamp: 2015-09-09 18:45:38
INTERIORLIGHTS:ELECTRICITY [J] | TASKLIGHTS:INTERIORLIGHTS:ELECTRICITY [Invalid/Undefined] | EXTERIORLIGHTS:ELECTRICITY [J] | GENERAL:INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | HUMIDIFIER:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [Invalid/Undefined] | |
January | 0.608042E+10 | 0.00 | 0.140604E+10 | 0.443459E+10 | 0.00 | 0.198060E+10 | 0.02 | 13457423.80 | 0.206079E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
February | 0.549726E+10 | 0.00 | 0.121328E+10 | 0.400939E+10 | 0.00 | 0.179236E+10 | 0.02 | 4884148.50 | 0.230390E+10 | 0.00 | 0.00 | 0.00 | 0.138378E+10 | 0.00 |
March | 0.640688E+10 | 0.00 | 0.126667E+10 | 0.468012E+10 | 0.00 | 0.216923E+10 | 0.02 | 20429640.04 | 0.279204E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
April | 0.583162E+10 | 0.00 | 0.115091E+10 | 0.425193E+10 | 0.00 | 0.188723E+10 | 0.02 | 0.00 | 0.304937E+10 | 0.00 | 0.00 | 0.00 | 0.148262E+10 | 0.00 |
May | 0.624365E+10 | 0.00 | 0.112168E+10 | 0.455735E+10 | 0.00 | 0.207615E+10 | 0.02 | 0.00 | 0.430721E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
June | 0.615808E+10 | 0.00 | 0.105481E+10 | 0.449747E+10 | 0.00 | 0.207900E+10 | 0.02 | 0.00 | 0.544183E+10 | 0.00 | 0.00 | 0.00 | 0.148262E+10 | 0.00 |
July | 0.591719E+10 | 0.00 | 0.109977E+10 | 0.431182E+10 | 0.00 | 0.190183E+10 | 0.02 | 0.00 | 0.548170E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
August | 0.640688E+10 | 0.00 | 0.115934E+10 | 0.468012E+10 | 0.00 | 0.217602E+10 | 0.02 | 0.00 | 0.605722E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
September | 0.583162E+10 | 0.00 | 0.119418E+10 | 0.425193E+10 | 0.00 | 0.189851E+10 | 0.02 | 0.00 | 0.512918E+10 | 0.00 | 0.00 | 0.00 | 0.148262E+10 | 0.00 |
October | 0.608042E+10 | 0.00 | 0.131163E+10 | 0.443459E+10 | 0.00 | 0.198383E+10 | 0.02 | 0.00 | 0.428743E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
November | 0.599485E+10 | 0.00 | 0.133860E+10 | 0.437470E+10 | 0.00 | 0.198083E+10 | 0.02 | 4045216.88 | 0.342176E+10 | 0.00 | 0.00 | 0.00 | 0.148262E+10 | 0.00 |
December | 0.591719E+10 | 0.00 | 0.142065E+10 | 0.431182E+10 | 0.00 | 0.188876E+10 | 0.02 | 21222174.00 | 0.209641E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
Annual Sum or Average | 0.723661E+11 | 0.00 | 0.147376E+11 | 0.527958E+11 | 0.00 | 0.238144E+11 | 0.24 | 64038603.22 | 0.464288E+11 | 0.00 | 0.00 | 0.00 | 0.180386E+11 | 0.00 |
Minimum of Months | 0.549726E+10 | 0.00 | 0.105481E+10 | 0.400939E+10 | 0.00 | 0.179236E+10 | 0.02 | 0.00 | 0.206079E+10 | 0.00 | 0.00 | 0.00 | 0.138378E+10 | 0.00 |
Maximum of Months | 0.640688E+10 | 0.00 | 0.142065E+10 | 0.468012E+10 | 0.00 | 0.217602E+10 | 0.02 | 21222174.00 | 0.605722E+10 | 0.00 | 0.00 | 0.00 | 0.153204E+10 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - NATURAL GAS
For: Meter
Timestamp: 2015-09-09 18:45:38
INTERIOREQUIPMENT:GAS [Invalid/Undefined] | EXTERIOREQUIPMENT:GAS [Invalid/Undefined] | HEATING:GAS [J] | COOLING:GAS [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | COGENERATION:GAS [Invalid/Undefined] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PEAK ENERGY END-USE - ELECTRICITY PART 1
For: Meter
Timestamp: 2015-09-09 18:45:38
INTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | TASKLIGHTS:INTERIORLIGHTS:ELECTRICITY [Invalid/Undefined] | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | GENERAL:INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | GENERAL:INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum}[W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 5078.61 | 02-JAN-08:09 | 0.00 | 936.61 | 01-JAN-00:10 | 3465.65 | 02-JAN-08:09 | 0.00 | 2015.27 | 02-JAN-09:20 | 0.00 | 23-JAN-09:30 | 1275.89 | 25-JAN-06:10 |
February | 5078.61 | 01-FEB-08:09 | 0.00 | 936.61 | 01-FEB-00:10 | 3465.65 | 01-FEB-08:09 | 0.00 | 2015.27 | 01-FEB-09:20 | 0.00 | 22-FEB-09:20 | 576.44 | 03-FEB-06:10 |
March | 5078.61 | 01-MAR-08:09 | 0.00 | 936.61 | 01-MAR-00:10 | 3465.65 | 01-MAR-08:09 | 0.00 | 2015.27 | 01-MAR-08:20 | 0.00 | 02-MAR-08:39 | 2063.71 | 16-MAR-05:10 |
April | 5078.61 | 03-APR-07:10 | 0.00 | 936.61 | 01-APR-00:10 | 3465.65 | 03-APR-07:10 | 0.00 | 2015.27 | 03-APR-07:30 | 0.00 | 10-APR-07:00 | 0.00 | 01-APR-00:10 |
May | 5078.61 | 01-MAY-07:10 | 0.00 | 936.61 | 01-MAY-00:10 | 3465.65 | 01-MAY-07:10 | 0.00 | 2015.27 | 01-MAY-07:40 | 0.00 | 02-MAY-17:19 | 0.00 | 01-MAY-00:10 |
June | 5078.61 | 01-JUN-07:10 | 0.00 | 936.61 | 01-JUN-00:10 | 3465.65 | 01-JUN-07:10 | 0.00 | 2015.27 | 01-JUN-05:10 | 0.00 | 09-JUN-17:19 | 0.00 | 01-JUN-00:10 |
July | 5078.61 | 03-JUL-07:10 | 0.00 | 936.61 | 01-JUL-00:10 | 3465.65 | 03-JUL-07:10 | 0.00 | 2015.27 | 03-JUL-09:09 | 0.00 | 05-JUL-15:39 | 0.00 | 01-JUL-00:10 |
August | 5078.61 | 01-AUG-07:10 | 0.00 | 936.61 | 01-AUG-00:10 | 3465.65 | 01-AUG-07:10 | 0.00 | 2015.27 | 01-AUG-10:20 | 0.00 | 01-AUG-10:00 | 0.00 | 01-AUG-00:10 |
September | 5078.61 | 01-SEP-07:10 | 0.00 | 936.61 | 01-SEP-00:10 | 3465.65 | 01-SEP-07:10 | 0.00 | 2015.27 | 01-SEP-07:00 | 0.00 | 27-SEP-08:39 | 0.00 | 01-SEP-00:10 |
October | 5078.61 | 02-OCT-07:10 | 0.00 | 936.61 | 01-OCT-00:10 | 3465.65 | 02-OCT-07:10 | 0.00 | 2015.27 | 02-OCT-11:20 | 0.00 | 04-OCT-14:09 | 0.00 | 01-OCT-00:10 |
November | 5078.61 | 01-NOV-07:10 | 0.00 | 936.61 | 01-NOV-00:10 | 3465.65 | 01-NOV-07:10 | 0.00 | 2015.27 | 01-NOV-05:10 | 0.00 | 01-NOV-06:10 | 902.53 | 13-NOV-06:10 |
December | 5078.61 | 01-DEC-08:09 | 0.00 | 936.61 | 01-DEC-00:10 | 3465.65 | 01-DEC-08:09 | 0.00 | 2015.27 | 01-DEC-06:10 | 0.00 | 14-DEC-09:39 | 2015.93 | 15-DEC-06:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 5078.61 | 0.00 | 936.61 | 3465.65 | 0.00 | 2015.27 | 0.00 | 0.00 | ||||||
Maximum of Months | 5078.61 | 0.00 | 936.61 | 3465.65 | 0.00 | 2015.27 | 0.00 | 2063.71 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:45:38
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.175079E+11 | 16725.198 | 02-JAN-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5593.670 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
February | 0.162049E+11 | 16065.812 | 10-FEB-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
March | 0.188674E+11 | 16716.528 | 13-MAR-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5585.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
April | 0.176537E+11 | 17235.552 | 14-APR-14:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6104.023 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
May | 0.198381E+11 | 17622.463 | 22-MAY-13:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6490.934 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
June | 0.207138E+11 | 18262.315 | 08-JUN-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7130.786 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
July | 0.202444E+11 | 19194.026 | 28-JUL-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
August | 0.220116E+11 | 18772.807 | 21-AUG-15:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7641.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
September | 0.197881E+11 | 18605.406 | 18-SEP-15:30 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 7473.877 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
October | 0.196299E+11 | 17931.181 | 03-OCT-14:50 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6799.652 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
November | 0.185974E+11 | 17187.471 | 03-NOV-13:00 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 6055.942 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
December | 0.171881E+11 | 16628.458 | 08-DEC-15:39 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 5496.929 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.228245E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
Minimum of Months | 0.162049E+11 | 16065.812 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 4934.283 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.220116E+11 | 19194.026 | 5078.615 | 3465.647 | 2015.267 | 0.000 | 8062.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 572.000 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 18:45:38
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.000 | 0.000 | 01-JAN-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.000 | 0.000 | 01-FEB-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.000 | 0.000 | 01-MAR-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.000 | 0.000 | 01-APR-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.000 | 0.000 | 01-MAY-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.000 | 0.000 | 01-JUN-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.000 | 0.000 | 01-JUL-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.000 | 0.000 | 01-OCT-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.000 | 0.000 | 01-NOV-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.000 | 0.000 | 01-DEC-00:10 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |