Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2020-06-03 19:11:32
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1498.44 | 653.20 | 653.20 |
Net Site Energy | 1498.44 | 653.20 | 653.20 |
Total Source Energy | 4571.58 | 1992.85 | 1992.85 |
Net Source Energy | 4571.58 | 1992.85 | 1992.85 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 798.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 213.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 38.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 170.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 83.52 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1414.92 | 83.52 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 798.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 213.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 38.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 194.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 170.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 83.52 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 109.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 422.38 | 36.41 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 616.79 | 36.41 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 109.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 422.38 | 36.41 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 616.79 | 36.41 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1414.917 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1414.917 | 100.00 |
Total On-Site and Utility Electric Sources | 1414.917 | 100.00 |
Total Electricity End Uses | 1414.917 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1014.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Latitude [deg] | 10.82 |
Longitude [deg] | 106.67 |
Elevation [m] | 5.00 |
Time Zone | 7.00 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 4.6739 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 11.3021 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.3021 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.3021 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 9.0417 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.1926 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.1926 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 13-JUN-14:00 | 10-JAN-12:20 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 70738.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 15745.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 14620.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 4789.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 111846.44 | 4789.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 70738.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 15745.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 14620.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 4789.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2530.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 674.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 122.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 615.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 538.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 90.54 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4481.04 | 90.54 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1102.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 294.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 53.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 234.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 39.47 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1953.38 | 39.47 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1102.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 294.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 53.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 234.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 39.47 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1953.38 | 39.47 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 2.21 |
CORE_RETAIL DIRECT AIR | 7.08 |
POINT_OF_SALE DIRECT AIR | 1.12 |
FRONT_RETAIL DIRECT AIR | 0.954545 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 0.014172 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 0.014172 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 417.46 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 51159.63 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 164143.16 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 25715.11 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 22025.25 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 2.21 | 2.21 | 2.21 | 2.21 | 2.21 | 2.21 | 1.00 | 1.00 | 2.21 |
PSZ-AC:2 | 7.08 | 7.08 | 7.08 | 7.08 | 7.35 | 7.35 | 1.00 | 0.963735 | 7.35 |
PSZ-AC:3 | 1.12 | 1.12 | 1.12 | 1.12 | 1.14 | 1.14 | 1.00 | 0.979869 | 1.14 |
PSZ-AC:4 | 0.954545 | 0.954545 | 0.954545 | 0.954545 | 0.954545 | 0.954545 | 1.00 | 1.00 | 0.954545 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 2.21 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 7.35 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.14 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.954545 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 2.21 | 2.21 | 2.21 | 1.46 | 46180.03 | 51159.63 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 7.35 | 7.35 | 7.35 | 4.85 | 182521.87 | 164143.16 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.14 | 1.14 | 1.14 | 0.751729 | 25422.93 | 25715.11 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.954545 | 0.954545 | 0.954545 | 0.629999 | 22359.65 | 22025.25 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 2.21 | 1.10 | 1.47 | 43369.10 | 46180.03 | 23090.01 | 23090.01 | 0.721780 | 0.721780 | 0.721780 | 0.721780 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 7.35 | 3.68 | 4.90 | 182399.43 | 182521.87 | 91260.93 | 91260.93 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.14 | 0.569490 | 0.759320 | 23998.37 | 25422.93 | 12711.47 | 12711.47 | 0.703661 | 0.703660 | 0.703660 | 0.703660 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.954540 | 0.477270 | 0.636360 | 21183.80 | 22359.65 | 11179.83 | 11179.83 | 0.690813 | 0.690810 | 0.690810 | 0.690810 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.21 | 2360.96 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 7.35 | 12382.91 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.14 | 1261.04 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.954545 | 1056.83 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 27.60 | 3.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 4.674 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 12.744 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 11.302 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 14.532 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 11.302 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 32.822 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 11.302 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 14.532 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 9.042 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.042 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 1775.580 | 4.674 | 28.946 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1775.580 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 18088.827 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 18088.827 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 1704.471 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1704.471 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 1704.471 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1704.471 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 108.500 | 9.042 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 108.500 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.761 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 5.069 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5677 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2994E-01 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.7613636 | 1.7613636 | 1.7613636 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 9 | -0.34109306E-14 | 0.24909287E-15 | -0.70234472E-12 | 0.65513238E-16 |
25 | 8 | 0.13119258E-09 | 0.66225198E-13 | 0.25869970E-04 | -0.14916918E-11 |
26 | 7 | -0.11009939E-02 | 0.13568249E-07 | -0.65256785E-02 | 0.12518681E-04 |
27 | 6 | 0.10140049 | 0.81303169E-05 | 0.18905580 | -0.11654411E-02 |
28 | 5 | -2.2086417 | 0.46066432E-03 | -2.1793248 | 0.26223950E-01 |
29 | 4 | 19.715055 | 0.51780401E-02 | 12.415669 | -0.24584718 |
30 | 3 | -82.671456 | 0.14472115E-01 | -37.782151 | 1.1032137 |
31 | 2 | 168.49726 | 0.99923307E-02 | 62.094262 | -2.4465849 |
32 | 1 | -160.45852 | 0.12849016E-02 | -51.628788 | 2.5579517 |
33 | 0 | 57.057407 | 0.91053392E-05 | 16.929182 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 30 | 1 | VerySmooth | 2.843 | 0.232 | 0.142 | 0.254 |
2 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 31 | 1 | VerySmooth | 3.979 | 0.301 | 0.178 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 1.97990E-002 | 0.14129 | 0.63099 | 0.63099 | 0.25300 | 0.16079 | 0.23715 | 0.00000 | 0.84000 | 0.84000 | 0.10909 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.17728 | 0.47032 | 0.47032 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 2.40661E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1915 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 1.419 | 0.118 | 3.899E-002 | 69.771 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 25044.12286 | 30052.94743 | 1.83867 | 2.20641 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 34.57667 | 1.71339E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 5916.27503 | 7099.53004 | 0.24856 | 0.29827 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 83919.45190 | 100703.34228 | 5.90300 | 7.08360 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 28.91000 | 1.71339E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 19618.55180 | 23542.26215 | 0.82091 | 1.89021 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 13018.77054 | 15622.52465 | 0.93004 | 1.11605 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 28.91000 | 1.71339E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 2822.06051 | 3386.47261 | 0.11840 | 0.17811 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 10834.72382 | 13001.66858 | 0.79545 | 0.95454 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 35.20000 | 1.71339E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 2822.06051 | 3386.47261 | 0.11840 | 0.17811 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20000 | 1.71339E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10000 | 1.47983E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 32642.77 | 2.20641 | 2.20641 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 7113.15 | 0.29827 | 0.29827 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 121544.62 | 7.35016 | 7.35016 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 45493.45 | 1.89021 | 1.89021 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 17644.73 | 1.13898 | 1.13898 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 4286.75 | 0.17811 | 0.17811 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 15237.41 | 0.95454 | 0.95454 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 4286.75 | 0.17811 | 0.17811 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.20641 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 7.08360 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.11605 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.95454 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.41723E-002 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 1.41723E-002 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 417.45501 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.20641 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.20641 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.20641 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.20641 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.20641 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.20641 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 7.08360 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 7.08360 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.08360 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 7.08360 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 7.35016 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 7.35016 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.96373 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.11605 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.11605 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.11605 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.11605 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.13898 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.13898 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 0.97987 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.95454 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.95454 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.95454 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.95454 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.95454 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.95454 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 2.20641 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 7.35016 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.13898 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.95454 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.20641 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.20641 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.20641 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.20641 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.45623 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.20641 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.10321 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.47094 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 43369.10311 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 46180.03000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 23090.01500 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 23090.01500 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72178 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72178 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72178 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72178 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 46180.03000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 51159.62924 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.20641 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2360.96275 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 51159.62924 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 7.35016 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 7.35016 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 7.35016 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 7.35016 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 4.85110 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 7.35016 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 3.67508 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 4.90011 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 182399.42792 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 182521.87000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 91260.93500 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 91260.93500 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 182521.87000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 164143.16075 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 7.35016 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 12382.91477 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 164143.16075 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.13898 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.13898 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.13898 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.13898 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75173 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.13898 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.56949 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.75932 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 23998.37059 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 25422.93000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12711.46500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 12711.46500 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70366 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70366 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70366 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70366 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 25422.93000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25715.11272 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.13898 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1261.03521 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25715.11272 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.95454 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.95454 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.95454 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.95454 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.63000 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.95454 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.47727 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.63636 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21183.79684 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22359.65000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11179.82500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11179.82500 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69081 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69081 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69081 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69081 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22359.65000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 22025.25263 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.95454 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1056.83229 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 22025.25263 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 44444.8 | 11.45 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 176723.2 | 13.59 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 24526.2 | 117.71 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 21607.4 | 146.50 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | N/A | 3.979 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 5.069 | 2.882 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 6 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 0.1281935240 | 0.1994055235 | Pass | Pass | 0.4543334579 | 1.3416415401 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 2.7515487671E-002 | 0.1256259760 | Pass | Pass | 5.9663943471E-002 | 0.3098298952 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 0.1671722353 | 0.2586004842 | Pass | Pass | 0.3878178007 | 0.8158075711 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 0.1430380163 | 0.2210276770 | Pass | Pass | 0.3964808152 | 0.8436104123 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 7.1311133062E-002 | 9.7452584732E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 2.882 | 5.069 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.7_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.979 | 0.301 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.23 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.843 | 0.232 | 0.254 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.23 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.843 | 0.232 | 0.254 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.23 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.843 | 0.232 | 0.254 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 3.093 | 0.247 | 0.286 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 3.093 | 0.247 | 0.286 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 4.6739 | 379.89 | 1775.58 | LightsWired | BLDG_LIGHT_BACK_SCH | 55.08 | 168.00 | 53.35 | 0.0000 | Y | 17.78 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 11.3021 | 1600.48 | 18088.83 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 45.40 | 0.0000 | Y | 154.17 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 11.3021 | 150.81 | 1704.47 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 65.23 | 0.0000 | Y | 20.87 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 11.3021 | 150.81 | 1704.47 | LightsWired | BLDG_LIGHT_FRONT_SCH | 67.15 | 168.00 | 63.20 | 0.0000 | Y | 20.22 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 9.0417 | 12.00 | 108.50 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 57.54 | 168.00 | 4.00 | 0.0000 | Y | 0.08 |
Interior Lighting Total | 10.1926 | 2293.99 | 23381.85 | 213.13 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 18088.83 | 4522.21 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 18088.83 | 4522.21 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 316.30 | AstronomicalClock | - | 41.93 | 41.93 | 2.49 | |
EXTERIOR_LIGHTS_B | 3054.90 | AstronomicalClock | - | 83.83 | 62.88 | 36.06 | |
Exterior Lighting Total | 3371.20 | 38.55 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 46180.03 | 33331.82 | 12848.21 | 0.72 | 3.73 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 182521.87 | 123399.39 | 59122.48 | 0.68 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 25422.93 | 17889.10 | 7533.83 | 0.70 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22359.65 | 15446.27 | 6913.38 | 0.69 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 44444.8 | 11.45 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 176723.2 | 13.59 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 24526.2 | 117.71 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 21607.4 | 146.50 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 417.46 | 0.81 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 51159.63 | 0.81 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 164143.16 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25715.11 | 0.81 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 22025.25 | 0.81 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.01 | 15.87 | 1120.11 | 1.00 | 15.42 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.21 | 2360.96 | 1070.05 | 1.00 | 1.30 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1018.41 | 7.35 | 12382.91 | 1684.71 | 1.00 | 1.16 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.14 | 1261.04 | 1107.16 | 1.00 | 1.37 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.95 | 1056.83 | 1107.16 | 1.00 | 1.41 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 25044.12 | 30052.95 | 79.11 | 1.839 | 2.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 23.89 | 23.89 | 0.00911 | 34.58 | 0.01713 | 0.232 | 0.00 |
CORE_RETAIL | 83919.45 | 100703.34 | 62.92 | 5.903 | 7.084 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 23.89 | 23.88 | 0.00989 | 28.91 | 0.01713 | 1.890 | 0.00 |
POINT_OF_SALE | 13018.77 | 15622.52 | 103.59 | 0.930 | 1.116 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 23.89 | 23.89 | 0.00905 | 28.91 | 0.01713 | 0.178 | 0.00 |
FRONT_RETAIL | 10834.72 | 13001.67 | 86.21 | 0.795 | 0.955 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 23.89 | 23.89 | 0.00907 | 35.20 | 0.01713 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 34.64 | 100.00 | 0.00001 | 35.20 | 0.01713 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 5916.28 | 7099.53 | 18.69 | 0.249 | 0.298 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.01004 | 20.10 | 0.01480 | 0.232 | 0.00 |
CORE_RETAIL | 19618.55 | 23542.26 | 14.71 | 0.821 | 1.890 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00857 | 20.10 | 0.01480 | 1.890 | 0.00 |
POINT_OF_SALE | 2822.06 | 3386.47 | 22.46 | 0.118 | 0.178 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.01001 | 20.10 | 0.01480 | 0.178 | 0.00 |
FRONT_RETAIL | 2822.06 | 3386.47 | 22.46 | 0.118 | 0.178 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.01001 | 20.10 | 0.01480 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 0.00 | 16.00 | 0.00800 | 20.10 | 0.01480 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 2.21 | 2.21 | 0.30 | 0.30 | 2.2064 | 2.2064 | 2.2064 | 1.0000 | 1.0000 |
PSZ-AC:2 | 7.35 | 7.35 | 1.89 | 1.89 | 7.3502 | 7.0836 | 7.3502 | 0.9637 | 1.0000 |
PSZ-AC:3 | 1.14 | 1.14 | 0.18 | 0.18 | 1.1390 | 1.1161 | 1.1390 | 0.9799 | 1.0000 |
PSZ-AC:4 | 0.95 | 0.95 | 0.18 | 0.18 | 0.9545 | 0.9545 | 0.9545 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 417.455 | 417.455 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 417.46 | 417.46 | 0.014172 | 16.00 | 12.90 | 0.00800000 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 16.00 | 0.00800000 | 70.7169 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 23090.015 | 0.000 | 2.206410 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 23090.01 | 18175.89 | 2.206410 | 25.06 | 17.95 | 0.00995890 | 12.80 | 12.09 | 0.00850000 | 35.03 | 0.01713394 | 25.76 | 10.4952 | 23.89 | 0.00911389 | 49.3211 | 24988.26 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 51159.629 | 51159.629 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 51159.63 | 51159.63 | 2.206410 | 20.28 | 19.36 | 0.01373308 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 10.4952 | 21.11 | 0.01003527 | 64.1949 | 5916.28 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 91260.935 | 0.000 | 7.350160 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 | 91260.93 | 62468.12 | 7.350160 | 26.86 | 19.60 | 0.01131602 | 12.80 | 12.09 | 0.00850000 | 35.13 | 0.01713393 | 25.78 | 25.7166 | 23.88 | 0.00988752 | 53.4517 | 81126.05 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 164143.161 | 164143.161 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 164143.16 | 164143.16 | 7.350156 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 25.7166 | 21.11 | 0.00857173 | 54.9633 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 12711.465 | 0.000 | 1.138980 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:00:00 | 12711.47 | 9685.64 | 1.138980 | 25.66 | 18.39 | 0.01026066 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 15.6377 | 23.89 | 0.00905089 | 48.9866 | 12872.34 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 25715.113 | 25715.113 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 17:30:00 | 25715.11 | 25715.11 | 1.138983 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 15.6377 | 21.11 | 0.01000515 | 64.0042 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 11179.825 | 0.000 | 0.954540 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 11179.83 | 8222.77 | 0.954540 | 26.00 | 18.75 | 0.01057436 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 18.6593 | 23.89 | 0.00906962 | 49.0848 | 10834.72 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 22025.253 | 22025.253 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 07:10:00 | 22025.25 | 22025.25 | 0.954545 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.6592 | 21.11 | 0.01000515 | 64.0042 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 417.455 | 417.455 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.014172 | 0.01705772 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 417.46 | 417.46 | 1.0000 | 0.01705772 | 0.014172 | 16.00 | 12.90 | 0.00800000 | 36322.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 417.46 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 16.00 | 0.00800000 | 16.00 | 0.00800000 | 70.7169 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 23090.015 | 0.000 | 2.206410 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.3531 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 23090.01 | 18175.89 | 1.0000 | 2.65562400 | 2.206410 | 25.06 | 17.95 | 0.00995890 | 50551.7 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23090.01 | 35.03 | 0.01713394 | 25.76 | 0.23156651 | 10.4952 | 23.89 | 0.00911547 | 23.89 | 0.00911389 | 49.3211 | 24988.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 51159.629 | 51159.629 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.206410 | 2.65562372 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 51159.63 | 51159.63 | 1.0000 | 2.65562372 | 2.206410 | 20.28 | 19.36 | 0.01373308 | 55243.6 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 51159.63 | 20.10 | 0.01479830 | 20.10 | 0.23156651 | 10.4952 | 20.91 | 0.01003527 | 21.11 | 0.01003527 | 64.1949 | 5916.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 91260.935 | 0.000 | 7.350160 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.8759 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 | 91260.93 | 62468.12 | 1.0000 | 8.84661569 | 7.350160 | 26.86 | 19.60 | 0.01131602 | 55856.6 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 91260.93 | 35.13 | 0.01713393 | 25.78 | 1.89021192 | 25.7166 | 23.89 | 0.00922415 | 23.88 | 0.00988752 | 53.4517 | 81126.05 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 164143.161 | 164143.161 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 7.350156 | 8.84661041 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 164143.16 | 164143.16 | 1.0000 | 8.84661041 | 7.350156 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 164143.16 | 20.10 | 0.01479830 | 20.10 | 1.89021192 | 25.7166 | 21.11 | 0.00000000 | 21.11 | 0.00857173 | 54.9633 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 12711.465 | 0.000 | 1.138980 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.9140 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:00:00 | 12711.47 | 9685.64 | 1.0000 | 1.37087061 | 1.138980 | 25.66 | 18.39 | 0.01026066 | 51939.6 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12711.47 | 35.20 | 0.01713393 | 25.80 | 0.17811053 | 15.6377 | 23.89 | 0.00898004 | 23.89 | 0.00905089 | 48.9866 | 12872.34 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25715.113 | 25715.113 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.138983 | 1.37087447 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 17:30:00 | 25715.11 | 25715.11 | 1.0000 | 1.37087447 | 1.138983 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25715.11 | 20.10 | 0.01479830 | 20.10 | 0.17811053 | 15.6377 | 21.11 | 0.00000000 | 21.11 | 0.01000515 | 64.0042 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11179.825 | 0.000 | 0.954540 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.4972 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 11179.83 | 8222.77 | 1.0000 | 1.14887955 | 0.954540 | 26.00 | 18.75 | 0.01057436 | 53081.4 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11179.83 | 35.20 | 0.01713393 | 25.80 | 0.17811053 | 18.6593 | 23.89 | 0.00906962 | 23.89 | 0.00906962 | 49.0848 | 10834.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 22025.253 | 22025.253 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.954545 | 1.14888498 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 07:10:00 | 22025.25 | 22025.25 | 1.0000 | 1.14888498 | 0.954545 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22025.25 | 20.10 | 0.01479830 | 20.10 | 0.17811053 | 18.6592 | 21.11 | 0.00000000 | 21.11 | 0.01000515 | 64.0042 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 4901.50 | 56.83 | 56.83 |
CORE_RETAIL | 4913.00 | 1014.00 | 1014.00 |
POINT_OF_SALE | 4913.00 | 94.33 | 94.33 |
FRONT_RETAIL | 4912.83 | 302.17 | 302.17 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 4913.00 | 1014.00 | 1014.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 0.00 | 589.33 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.83 | 0.00 | 0.83 |
POINT_OF_SALE | 0.00 | 781.83 | 0.00 | 0.00 |
FRONT_RETAIL | 0.00 | 713.83 | 0.00 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.00 | 784.50 | 0.00 | 0.83 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.50 | 61.34 | 2317.33 | 0.372 | 0.020 | 0.000 | 0.000 |
CORE_RETAIL | 128.48 | 258.43 | 9762.95 | 0.721 | 0.004 | 0.000 | 0.000 |
POINT_OF_SALE | 12.11 | 24.35 | 919.94 | 0.720 | 0.021 | 0.000 | 0.000 |
FRONT_RETAIL | 12.11 | 24.35 | 919.94 | 0.720 | 0.021 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.50 | 61.34 | 2317.33 | 0.364 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.48 | 258.43 | 9762.95 | 0.706 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.11 | 24.35 | 919.94 | 0.705 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.11 | 24.35 | 919.94 | 0.705 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
Electricity:Building | 407.42 | 2265.44 | 01-JAN-00:10 | 31292.41 | 02-JAN-17:40 |
Electricity:Zone:BACK_SPACE | 67.55 | 535.60 | 01-JAN-00:10 | 4001.15 | 02-JAN-09:10 |
InteriorLights:Electricity | 213.13 | 493.85 | 01-JAN-00:10 | 20551.52 | 02-JAN-17:40 |
InteriorLights:Electricity:Zone:BACK_SPACE | 17.78 | 81.78 | 01-JAN-00:10 | 1249.73 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 213.13 | 493.85 | 01-JAN-00:10 | 20551.52 | 02-JAN-17:40 |
Electricity:Zone:CORE_RETAIL | 238.10 | 1109.80 | 01-JAN-00:10 | 20919.52 | 02-JAN-17:40 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 154.17 | 344.55 | 01-JAN-00:10 | 16279.94 | 02-JAN-17:40 |
Electricity:Zone:POINT_OF_SALE | 73.56 | 512.89 | 01-JAN-00:10 | 4446.74 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 20.87 | 32.47 | 01-JAN-00:10 | 1534.02 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 28.13 | 104.57 | 01-JAN-00:10 | 1922.42 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 20.22 | 32.47 | 01-JAN-00:10 | 1485.24 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 0.08 | 2.58 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 0.08 | 2.58 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 |
InteriorEquipment:Electricity | 194.30 | 1771.59 | 01-JAN-00:10 | 10740.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.77 | 453.82 | 01-JAN-00:10 | 2751.42 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 194.30 | 1771.59 | 01-JAN-00:10 | 10740.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 83.93 | 765.25 | 01-JAN-00:10 | 4639.58 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.69 | 480.42 | 01-JAN-00:10 | 2912.71 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.91 | 72.11 | 01-JAN-00:10 | 437.18 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
ElectricityPurchased:Plant | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
Cogeneration:ElectricityPurchased | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
ElectricityNet:Plant | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
Cogeneration:ElectricityNet | 1414.92 | 2265.44 | 08-JAN-06:40 | 111846.44 | 13-JUN-15:00 |
Electricity:HVAC | 968.95 | 0.00 | 01-JAN-19:40 | 85359.61 | 13-JUN-15:00 |
Fans:Electricity | 170.04 | 0.00 | 01-JAN-19:40 | 14620.82 | 13-JUN-15:00 |
General:Fans:Electricity | 170.04 | 0.00 | 01-JAN-19:40 | 14620.82 | 13-JUN-15:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 798.90 | 0.00 | 01-JAN-19:40 | 70738.80 | 13-JUN-15:00 |
ExteriorLights:Electricity | 38.55 | 0.00 | 01-JAN-06:20 | 3371.20 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 38.55 | 0.00 | 01-JAN-06:20 | 3371.20 | 01-JAN-06:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 83.52 | 1860.00 | 16-JAN-08:10 | 4789.88 | 10-JAN-12:20 |
Gas:Plant | 83.52 | 1860.00 | 16-JAN-08:10 | 4789.88 | 10-JAN-12:20 |
WaterSystems:Gas | 83.52 | 1860.00 | 16-JAN-08:10 | 4789.88 | 10-JAN-12:20 |
Water Heater:WaterSystems:Gas | 83.52 | 1860.00 | 16-JAN-08:10 | 4789.88 | 10-JAN-12:20 |
Gas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:Gas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 4520.10 | 0.00 | 01-JAN-19:40 | 359268.89 | 13-JUN-15:00 |
EnergyTransfer:Building | 1366.49 | 0.00 | 01-JAN-19:40 | 107316.04 | 06-MAY-15:30 |
EnergyTransfer:Zone:BACK_SPACE | 307.31 | 0.00 | 01-JAN-00:10 | 24163.08 | 13-JUN-16:00 |
Heating:EnergyTransfer | 2.24 | 0.00 | 01-JAN-00:10 | 10544.37 | 05-MAY-05:20 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 0.02 | 0.00 | 01-JAN-00:10 | 1079.69 | 01-JUL-05:10 |
Cooling:EnergyTransfer | 1364.25 | 0.00 | 01-JAN-19:40 | 107316.04 | 06-MAY-15:30 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 307.29 | 0.00 | 01-JAN-00:10 | 24163.08 | 13-JUN-16:00 |
EnergyTransfer:Zone:CORE_RETAIL | 720.95 | 0.00 | 01-JAN-00:10 | 62259.50 | 06-MAY-15:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 2.21 | 0.00 | 01-JAN-00:10 | 10544.37 | 05-MAY-05:20 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 718.74 | 0.00 | 01-JAN-00:10 | 62259.50 | 06-MAY-15:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 186.93 | 0.00 | 01-JAN-00:40 | 13471.40 | 07-DEC-15:30 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 0.01 | 0.00 | 01-JAN-00:10 | 516.27 | 05-AUG-05:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 186.92 | 0.00 | 01-JAN-00:40 | 13471.40 | 07-DEC-15:30 |
EnergyTransfer:Zone:FRONT_RETAIL | 151.30 | 0.00 | 01-JAN-00:40 | 11621.65 | 07-DEC-15:20 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 0.01 | 0.00 | 01-JAN-00:10 | 450.05 | 20-AUG-07:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 151.30 | 0.00 | 01-JAN-00:40 | 11621.65 | 07-DEC-15:20 |
EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 3153.61 | 0.00 | 01-JAN-19:40 | 254907.72 | 13-JUN-15:00 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 3153.61 | 0.00 | 01-JAN-19:40 | 254907.72 | 13-JUN-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 0.017 | -307.289 | 0.000 | 0.000 | 36.671 | 17.781 | 49.772 | 0.000 | 0.000 | 2.643 | 200.506 | 0.000 | 0.000 | 0.000 | -0.100 | -0.000 |
CORE_RETAIL | 0.000 | 0.000 | 2.211 | -718.711 | 0.000 | 0.000 | 154.451 | 154.171 | 83.927 | 44.400 | 0.000 | 1.518 | 283.700 | 0.000 | -5.290 | 0.000 | -0.378 | -0.010 |
POINT_OF_SALE | 0.000 | 0.000 | 0.007 | -186.920 | 0.000 | 0.000 | 14.558 | 20.870 | 52.689 | 26.248 | 0.000 | 1.137 | 73.597 | 0.000 | -2.139 | 0.000 | -0.047 | -0.000 |
FRONT_RETAIL | 0.000 | 0.000 | 0.006 | -151.294 | 0.000 | 0.000 | 14.558 | 20.222 | 7.908 | 26.055 | 0.000 | 1.143 | 83.496 | 0.000 | -2.050 | 0.000 | -0.045 | -0.000 |
FRONT_ENTRY | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.081 | 0.000 | 4.361 | 0.000 | 2.863 | 0.000 | 0.000 | -0.923 | 0.000 | -1.111 | -5.271 |
Total Facility | 0.000 | 0.000 | 2.241 | -1364.214 | 0.000 | 0.000 | 220.239 | 213.126 | 194.297 | 101.064 | 0.000 | 9.304 | 641.299 | 0.000 | -10.402 | 0.000 | -1.682 | -5.282 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 20-JUL-01:23 | 0.00 | 0.00 | 0.00 | -34381.50 | 0.00 | 0.00 | 0.00 | 81.78 | 605.09 | 0.00 | 0.00 | 0.00 | 33694.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 24-FEB-07:02 | 0.00 | 0.00 | 0.00 | -118209.10 | 0.00 | 0.00 | 1601.36 | 344.55 | 2062.04 | 0.00 | 0.00 | 0.00 | 114280.54 | 0.00 | -64.51 | 0.00 | -14.87 | 0.00 |
POINT_OF_SALE | 20-DEC-21:08 | 0.00 | 0.00 | 0.00 | -19349.34 | 0.00 | 0.00 | 0.00 | 340.89 | 640.56 | 0.00 | 0.00 | 0.00 | 18861.46 | 0.00 | -449.53 | 0.00 | -44.04 | 0.00 |
FRONT_RETAIL | 23-JAN-23:43 | 0.00 | 0.00 | 0.00 | -16481.51 | 0.00 | 0.00 | 0.00 | 32.47 | 96.14 | 0.00 | 0.00 | 0.00 | 16848.29 | 0.00 | -452.98 | 0.00 | -42.41 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 07-MAY-07:02 | 0.00 | 0.00 | 0.00 | -150741.92 | 0.00 | 0.00 | 0.00 | 493.85 | 1771.59 | 2993.31 | 0.00 | 384.59 | 145098.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 11-JUN-07:08 | 0.00 | 0.00 | 2507.92 | 0.00 | 0.00 | 0.00 | 0.00 | 81.78 | 453.82 | 0.00 | 0.00 | 92.87 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3136.39 |
CORE_RETAIL | 28-MAY-07:05 | 0.00 | 0.00 | 21501.42 | 0.00 | 0.00 | 0.00 | 0.00 | 344.55 | 765.25 | 1419.59 | 0.00 | 36.14 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -24066.95 |
POINT_OF_SALE | 14-MAY-07:07 | 0.00 | 0.00 | 1521.69 | 0.00 | 0.00 | 0.00 | 0.00 | 32.47 | 480.42 | 679.45 | 0.00 | 14.91 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2728.94 |
FRONT_RETAIL | 14-MAY-07:07 | 0.00 | 0.00 | 1344.88 | 0.00 | 0.00 | 0.00 | 0.00 | 32.47 | 72.11 | 683.01 | 0.00 | 14.47 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2146.93 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 28-MAY-07:05 | -5389.27 | 5389.27 | 21501.42 | -5389.27 | 0.00 | 0.00 | 0.00 | 493.85 | 1771.59 | 3705.92 | 0.00 | 768.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -22852.37 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2064 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2064 | 0.1050 | 1.0000 | 0.2316 | 0.1050 | ||
PSZ-AC:2 | 7.0836 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.3502 | 0.2572 | 1.0000 | 1.8902 | 0.2572 | ||
PSZ-AC:3 | 1.1161 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1390 | 0.1564 | 1.0000 | 0.1781 | 0.1564 | ||
PSZ-AC:4 | 0.9545 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9545 | 0.1866 | 1.0000 | 0.1781 | 0.1866 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2064 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2064 | 1.0000 | 1.0000 | 0.2316 | 0.1050 | ||
PSZ-AC:2 | 7.0836 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.0836 | 1.0000 | 1.0000 | 1.8902 | 0.2668 | ||
PSZ-AC:3 | 1.1161 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1161 | 1.0000 | 1.0000 | 0.1781 | 0.1596 | ||
PSZ-AC:4 | 0.9545 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9545 | 1.0000 | 1.0000 | 0.1781 | 0.1866 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2064 | 2.2064 | 2.2064 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.0836 | 7.0836 | 7.0836 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1161 | 1.1161 | 1.1161 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9545 | 0.9545 | 0.9545 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2064 | 2.2064 | 2.2064 | 2.2064 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.0836 | 7.3502 | 7.0836 | 7.0836 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1161 | 1.1390 | 1.1161 | 1.1161 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9545 | 0.9545 | 0.9545 | 0.9545 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2064 | 2.2064 | 2.2064 | 0.2316 | 0.7764 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.0836 | 7.0836 | 7.0836 | 1.8902 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1161 | 1.1161 | 1.1161 | 0.1781 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9545 | 0.9545 | 0.9545 | 0.1781 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2064 | 2.2064 | 2.2064 | 2.2064 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.0836 | 7.0836 | 7.0836 | 7.0836 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1161 | 1.1161 | 1.1161 | 1.1161 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9545 | 0.9545 | 0.9545 | 0.9545 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Total gross floor area [m2] | 2293.99 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.83 |
Number of hours not met | 0.83 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 798.90 | 70738.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 213.13 | 20551.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 38.55 | 3371.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 194.30 | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 170.04 | 14620.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 83.52 | 4789.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 194.30 | 1414.92 |
Natural Gas | 0.00 | 83.52 |
Additional | 0.00 | 0.00 |
Total | 194.30 | 1498.44 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 92.91 |
Space Heating | 0.00 |
Space Cooling | 348.26 |
Fans (All) | 74.13 |
Service Water Heating | 0.00 |
Receptacle Equipment | 84.70 |
Miscellaneous (All) | 616.79 |
Subtotal | 616.79 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 36.41 |
Miscellaneous (All) | 36.41 |
Subtotal | 36.41 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 14.22 |
Space Heating | 0.00 |
Space Cooling | 53.32 |
Fans (All) | 11.35 |
Service Water Heating | 5.57 |
Receptacle Equipment | 12.97 |
Miscellaneous | 2.57 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 2872. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3001. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3501. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4552. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6570. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_SETBACK | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
HTGSETP_SCH_YES_OPTIMUM | CORE_RETAIL DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_RETAIL DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
HTGSETP_SCH_FRONTENTRY_STD2013 | FRONT_ENTRY DUALSPSCHED | January | 16.00 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.214365E+11 | 33370.92 | 15-JAN-19:08 | 26.75 | 20.92 | 0.218396E+10 | 2451.26 | 21-JAN-11:30 | 29.75 | 22.42 |
February | 0.220017E+11 | 34120.12 | 24-FEB-21:07 | 27.38 | 21.31 | 0.199424E+10 | 2451.28 | 21-FEB-15:00 | 31.90 | 23.95 |
March | 0.267782E+11 | 32969.01 | 21-MAR-20:06 | 27.00 | 22.86 | 0.228099E+10 | 2451.25 | 16-MAR-14:09 | 31.83 | 24.83 |
April | 0.282848E+11 | 32623.66 | 22-APR-00:43 | 24.17 | 23.00 | 0.215631E+10 | 2451.22 | 15-APR-11:20 | 32.67 | 26.00 |
May | 0.311156E+11 | 33298.00 | 11-MAY-01:23 | 24.10 | 24.04 | 0.223240E+10 | 2451.28 | 06-MAY-14:30 | 37.00 | 27.33 |
June | 0.340025E+11 | 33594.18 | 27-JUN-02:63 | 24.00 | 24.00 | 0.220150E+10 | 2451.28 | 15-JUN-14:00 | 35.00 | 28.15 |
July | 0.290906E+11 | 34382.87 | 20-JUL-01:23 | 23.75 | 22.63 | 0.218721E+10 | 2451.22 | 12-JUL-14:00 | 27.00 | 25.53 |
August | 0.264806E+11 | 33591.08 | 24-AUG-02:63 | 23.17 | 23.17 | 0.228095E+10 | 2451.21 | 31-AUG-14:30 | 30.00 | 26.22 |
September | 0.247115E+11 | 32529.54 | 10-SEP-03:03 | 24.55 | 24.09 | 0.215633E+10 | 2451.22 | 19-SEP-14:09 | 30.83 | 27.18 |
October | 0.217643E+11 | 32315.22 | 09-OCT-03:23 | 24.55 | 23.48 | 0.218393E+10 | 2451.24 | 30-OCT-14:09 | 23.92 | 23.86 |
November | 0.211783E+11 | 31288.78 | 15-NOV-02:23 | 25.00 | 24.24 | 0.210123E+10 | 2451.25 | 21-NOV-15:09 | 31.30 | 25.02 |
December | 0.204490E+11 | 33968.22 | 20-DEC-21:10 | 22.83 | 18.42 | 0.218727E+10 | 2451.23 | 12-DEC-15:00 | 30.80 | 25.54 |
Annual Sum or Average | 0.307293E+12 | 0.261463E+11 | ||||||||
Minimum of Months | 0.204490E+11 | 31288.78 | 22.83 | 18.42 | 0.199424E+10 | 2451.21 | 23.92 | 22.42 | ||
Maximum of Months | 0.340025E+11 | 34382.87 | 27.38 | 24.24 | 0.228099E+10 | 2451.28 | 37.00 | 28.15 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.565782E+11 | 110354.09 | 28-JAN-07:03 | 20.42 | 18.63 | 0.920426E+10 | 10327.20 | 14-JAN-16:30 | 29.75 | 22.60 |
February | 0.559713E+11 | 118239.82 | 24-FEB-07:02 | 21.42 | 18.05 | 0.840510E+10 | 10326.99 | 25-FEB-12:50 | 31.17 | 22.17 |
March | 0.671740E+11 | 112230.24 | 21-MAR-05:03 | 24.83 | 22.05 | 0.961372E+10 | 10326.98 | 04-MAR-12:20 | 32.43 | 21.92 |
April | 0.660707E+11 | 107654.31 | 27-APR-05:03 | 26.00 | 23.87 | 0.908846E+10 | 10326.88 | 15-APR-11:20 | 32.67 | 26.00 |
May | 0.649651E+11 | 101891.97 | 31-MAY-05:03 | 24.17 | 24.17 | 0.940926E+10 | 10327.00 | 01-MAY-14:09 | 34.83 | 27.34 |
June | 0.661602E+11 | 102997.14 | 20-JUN-05:03 | 24.00 | 24.00 | 0.927903E+10 | 10326.84 | 17-JUN-11:20 | 33.33 | 27.32 |
July | 0.595838E+11 | 107253.56 | 31-JUL-05:03 | 24.15 | 23.23 | 0.921872E+10 | 10326.79 | 01-JUL-11:20 | 31.57 | 25.04 |
August | 0.600121E+11 | 101604.10 | 16-AUG-05:03 | 24.00 | 24.00 | 0.961367E+10 | 10327.04 | 19-AUG-14:50 | 25.00 | 24.56 |
September | 0.588554E+11 | 101825.53 | 14-SEP-05:03 | 25.42 | 24.32 | 0.908846E+10 | 10327.02 | 16-SEP-12:39 | 25.93 | 24.85 |
October | 0.547062E+11 | 95638.79 | 05-OCT-05:03 | 26.08 | 25.24 | 0.920469E+10 | 10326.92 | 11-OCT-14:50 | 24.42 | 24.42 |
November | 0.539178E+11 | 107283.35 | 25-NOV-07:03 | 21.17 | 18.83 | 0.885608E+10 | 10326.99 | 25-NOV-12:20 | 26.53 | 21.47 |
December | 0.547413E+11 | 104328.41 | 27-DEC-07:03 | 20.50 | 19.41 | 0.921827E+10 | 10327.28 | 27-DEC-15:50 | 31.17 | 22.62 |
Annual Sum or Average | 0.718736E+12 | 0.110200E+12 | ||||||||
Minimum of Months | 0.539178E+11 | 95638.79 | 20.42 | 18.05 | 0.840510E+10 | 10326.79 | 24.42 | 21.47 | ||
Maximum of Months | 0.671740E+11 | 118239.82 | 26.08 | 25.24 | 0.961372E+10 | 10327.28 | 34.83 | 27.34 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.175265E+11 | 18827.13 | 23-JAN-23:43 | 21.67 | 18.09 | 0.866960E+09 | 973.20 | 04-JAN-15:30 | 32.35 | 24.42 |
February | 0.161956E+11 | 18884.18 | 24-FEB-21:05 | 27.38 | 21.31 | 0.791647E+09 | 973.14 | 25-FEB-12:09 | 29.43 | 21.53 |
March | 0.169537E+11 | 18235.31 | 03-MAR-01:43 | 24.00 | 20.61 | 0.905487E+09 | 973.11 | 04-MAR-12:50 | 33.08 | 22.09 |
April | 0.152817E+11 | 16836.69 | 22-APR-00:43 | 24.17 | 23.00 | 0.856006E+09 | 973.08 | 15-APR-10:09 | 31.42 | 25.66 |
May | 0.154511E+11 | 16957.73 | 10-MAY-20:08 | 22.17 | 22.17 | 0.886222E+09 | 973.08 | 17-MAY-14:09 | 29.00 | 26.74 |
June | 0.154138E+11 | 16637.43 | 27-JUN-01:23 | 24.25 | 24.19 | 0.873960E+09 | 973.14 | 30-JUN-14:30 | 28.00 | 26.50 |
July | 0.141995E+11 | 17109.34 | 20-JUL-00:03 | 23.72 | 22.60 | 0.868280E+09 | 973.12 | 03-JUL-14:00 | 25.60 | 23.63 |
August | 0.139826E+11 | 16999.76 | 24-AUG-01:23 | 23.50 | 23.13 | 0.905493E+09 | 973.10 | 04-AUG-14:09 | 24.17 | 24.17 |
September | 0.144165E+11 | 16820.36 | 29-SEP-02:43 | 24.08 | 23.27 | 0.856012E+09 | 973.10 | 16-SEP-10:00 | 29.50 | 26.46 |
October | 0.145731E+11 | 17158.82 | 11-OCT-02:63 | 24.00 | 23.26 | 0.866959E+09 | 973.15 | 19-OCT-14:09 | 28.00 | 25.71 |
November | 0.157639E+11 | 18136.27 | 25-NOV-00:23 | 23.80 | 20.43 | 0.834121E+09 | 973.15 | 25-NOV-15:09 | 25.82 | 22.38 |
December | 0.171646E+11 | 19351.39 | 20-DEC-21:08 | 22.83 | 18.42 | 0.868275E+09 | 973.12 | 19-DEC-15:09 | 28.90 | 22.61 |
Annual Sum or Average | 0.186923E+12 | 0.103794E+11 | ||||||||
Minimum of Months | 0.139826E+11 | 16637.43 | 21.67 | 18.09 | 0.791647E+09 | 973.08 | 24.17 | 21.53 | ||
Maximum of Months | 0.175265E+11 | 19351.39 | 27.38 | 24.19 | 0.905493E+09 | 973.20 | 33.08 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.144795E+11 | 16482.58 | 23-JAN-23:43 | 21.67 | 18.09 | 0.866957E+09 | 973.16 | 04-JAN-15:09 | 32.78 | 24.18 |
February | 0.134498E+11 | 15994.91 | 24-FEB-21:05 | 27.38 | 21.31 | 0.791644E+09 | 973.12 | 28-FEB-15:20 | 34.20 | 24.47 |
March | 0.137695E+11 | 15562.85 | 03-MAR-01:43 | 24.00 | 20.61 | 0.905485E+09 | 973.10 | 03-MAR-15:30 | 32.90 | 23.56 |
April | 0.123220E+11 | 14123.75 | 22-APR-00:43 | 24.17 | 23.00 | 0.856013E+09 | 973.10 | 14-APR-14:00 | 27.00 | 25.11 |
May | 0.124669E+11 | 14071.17 | 10-MAY-20:08 | 22.17 | 22.17 | 0.886229E+09 | 973.12 | 06-MAY-14:39 | 37.00 | 27.33 |
June | 0.125305E+11 | 14069.48 | 20-JUN-04:03 | 24.08 | 23.67 | 0.873967E+09 | 973.12 | 30-JUN-14:50 | 28.67 | 27.14 |
July | 0.112535E+11 | 14574.85 | 31-JUL-04:03 | 24.35 | 23.15 | 0.868283E+09 | 973.11 | 12-JUL-14:09 | 27.42 | 25.11 |
August | 0.109738E+11 | 14359.44 | 24-AUG-01:23 | 23.50 | 23.13 | 0.905499E+09 | 973.11 | 16-AUG-14:20 | 27.33 | 26.35 |
September | 0.115502E+11 | 14268.99 | 29-SEP-02:43 | 24.08 | 23.27 | 0.856019E+09 | 973.12 | 16-SEP-15:00 | 27.40 | 25.35 |
October | 0.115177E+11 | 14607.10 | 08-OCT-03:03 | 23.93 | 23.23 | 0.866963E+09 | 973.09 | 14-OCT-11:20 | 29.50 | 26.25 |
November | 0.128474E+11 | 15537.30 | 25-NOV-01:03 | 24.07 | 20.46 | 0.834120E+09 | 973.11 | 25-NOV-14:50 | 25.95 | 22.31 |
December | 0.141360E+11 | 16480.98 | 20-DEC-21:08 | 22.83 | 18.42 | 0.868273E+09 | 973.18 | 08-DEC-15:09 | 32.77 | 23.58 |
Annual Sum or Average | 0.151297E+12 | 0.103795E+11 | ||||||||
Minimum of Months | 0.109738E+11 | 14069.48 | 21.67 | 18.09 | 0.791644E+09 | 973.09 | 25.95 | 22.31 | ||
Maximum of Months | 0.144795E+11 | 16482.58 | 27.38 | 23.67 | 0.905499E+09 | 973.18 | 37.00 | 27.33 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 | 23.60 | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 |
April | 0.00 | 0.00 | 01-APR-00:03 | 27.53 | 25.10 | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 28.62 | 26.40 | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 24.05 | 23.91 | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 25.40 | 24.33 | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 25.63 | 24.75 | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 26.53 | 25.66 | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 25.22 | 24.37 | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.00 | 0.00 | 23.80 | 22.46 | ||
Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.00 | 0.00 | 28.62 | 26.40 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 526416.80 | 1137.75 | 29-JAN-08:04 | 24.17 |
February | 819427.70 | 1736.64 | 26-FEB-08:07 | 25.33 |
March | 880964.81 | 2258.14 | 26-MAR-07:07 | 27.17 |
April | 1849555.96 | 2256.03 | 30-APR-07:05 | 28.10 |
May | 918813.05 | 1891.81 | 14-MAY-07:07 | 27.50 |
June | 837044.20 | 2507.67 | 11-JUN-07:08 | 28.50 |
July | 1425181.17 | 2159.38 | 01-JUL-05:05 | 25.88 |
August | 2108950.07 | 2148.07 | 27-AUG-07:07 | 26.67 |
September | 740494.14 | 2127.10 | 10-SEP-07:07 | 26.50 |
October | 3359735.17 | 2091.34 | 29-OCT-07:07 | 26.50 |
November | 2094286.75 | 1762.26 | 19-NOV-08:07 | 25.50 |
December | 994617.42 | 1230.10 | 31-DEC-08:05 | 24.67 |
Annual Sum or Average | 16555487.24 | |||
Minimum of Months | 526416.80 | 1137.75 | 24.17 | |
Maximum of Months | 3359735.17 | 2507.67 | 28.50 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 71873892.15 | 10502.07 | 11-JAN-07:20 | 26.40 |
February | 0.109442E+09 | 14918.67 | 20-FEB-09:08 | 28.23 |
March | 0.225466E+09 | 17895.97 | 26-MAR-08:08 | 29.33 |
April | 0.236693E+09 | 13118.49 | 11-APR-06:08 | 27.20 |
May | 0.210413E+09 | 21499.41 | 28-MAY-07:05 | 32.25 |
June | 0.192594E+09 | 13089.31 | 11-JUN-07:08 | 28.50 |
July | 0.221908E+09 | 14113.24 | 30-JUL-08:08 | 27.67 |
August | 0.220121E+09 | 12171.69 | 20-AUG-08:20 | 26.67 |
September | 0.226204E+09 | 11973.18 | 17-SEP-08:20 | 26.63 |
October | 0.239844E+09 | 15533.53 | 08-OCT-08:08 | 28.25 |
November | 0.176383E+09 | 16009.11 | 23-NOV-09:08 | 28.57 |
December | 79930197.95 | 14794.03 | 31-DEC-09:08 | 28.47 |
Annual Sum or Average | 0.221087E+10 | |||
Minimum of Months | 71873892.15 | 10502.07 | 26.40 | |
Maximum of Months | 0.239844E+09 | 21499.41 | 32.25 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 285989.21 | 694.43 | 29-JAN-08:04 | 24.17 |
February | 497129.85 | 1121.29 | 05-FEB-08:07 | 25.33 |
March | 556413.20 | 1429.73 | 26-MAR-07:07 | 27.17 |
April | 967938.31 | 1390.83 | 16-APR-07:07 | 26.78 |
May | 460483.77 | 1521.19 | 14-MAY-07:07 | 27.50 |
June | 379421.41 | 1002.46 | 18-JUN-07:05 | 28.00 |
July | 431795.76 | 1178.98 | 30-JUL-07:07 | 25.83 |
August | 1160752.77 | 1352.71 | 27-AUG-07:07 | 26.67 |
September | 410632.52 | 1320.34 | 10-SEP-07:07 | 26.50 |
October | 1026364.75 | 1118.25 | 01-OCT-07:07 | 25.50 |
November | 368769.26 | 1156.02 | 19-NOV-08:07 | 25.50 |
December | 321065.14 | 729.75 | 31-DEC-08:05 | 24.67 |
Annual Sum or Average | 6866755.97 | |||
Minimum of Months | 285989.21 | 694.43 | 24.17 | |
Maximum of Months | 1160752.77 | 1521.19 | 28.00 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 227072.47 | 577.58 | 29-JAN-08:04 | 24.17 |
February | 417087.70 | 959.24 | 05-FEB-08:07 | 25.33 |
March | 492727.85 | 1272.50 | 26-MAR-07:07 | 27.17 |
April | 894236.87 | 1230.23 | 16-APR-07:07 | 26.78 |
May | 429309.75 | 1344.43 | 14-MAY-07:07 | 27.50 |
June | 507825.91 | 1034.22 | 18-JUN-07:05 | 28.00 |
July | 372414.96 | 1031.03 | 30-JUL-07:07 | 25.83 |
August | 1122569.80 | 1200.67 | 27-AUG-07:07 | 26.67 |
September | 380397.80 | 1168.38 | 10-SEP-07:07 | 26.50 |
October | 1047919.77 | 945.98 | 01-OCT-07:07 | 25.50 |
November | 306265.04 | 979.67 | 19-NOV-08:07 | 25.50 |
December | 266109.87 | 634.67 | 31-DEC-08:05 | 24.67 |
Annual Sum or Average | 6463937.79 | |||
Minimum of Months | 227072.47 | 577.58 | 24.17 | |
Maximum of Months | 1122569.80 | 1344.43 | 28.00 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:03 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.149153E+10 | 1249.73 | 02-JAN-09:09 | 0.419292E+10 | 2751.42 | 02-JAN-09:09 |
February | 0.135698E+10 | 1249.73 | 01-FEB-09:09 | 0.380401E+10 | 2751.42 | 01-FEB-09:09 |
March | 0.154631E+10 | 1249.73 | 01-MAR-09:09 | 0.429860E+10 | 2751.42 | 01-MAR-09:09 |
April | 0.146057E+10 | 1249.73 | 01-APR-09:09 | 0.408483E+10 | 2751.42 | 01-APR-09:09 |
May | 0.151892E+10 | 1249.73 | 01-MAY-08:09 | 0.424576E+10 | 2751.42 | 01-MAY-08:09 |
June | 0.149233E+10 | 1249.73 | 01-JUN-08:09 | 0.415135E+10 | 2751.42 | 01-JUN-08:09 |
July | 0.148716E+10 | 1249.73 | 01-JUL-09:09 | 0.417924E+10 | 2751.42 | 01-JUL-09:09 |
August | 0.154631E+10 | 1249.73 | 01-AUG-08:09 | 0.429860E+10 | 2751.42 | 01-AUG-08:09 |
September | 0.146057E+10 | 1249.73 | 01-SEP-08:09 | 0.408483E+10 | 2751.42 | 01-SEP-08:09 |
October | 0.149153E+10 | 1249.73 | 02-OCT-08:09 | 0.419292E+10 | 2751.42 | 02-OCT-08:09 |
November | 0.144192E+10 | 1249.73 | 01-NOV-08:09 | 0.405935E+10 | 2751.42 | 01-NOV-08:09 |
December | 0.148716E+10 | 1249.73 | 01-DEC-09:09 | 0.417924E+10 | 2751.42 | 01-DEC-09:09 |
Annual Sum or Average | 0.177813E+11 | 0.497716E+11 | ||||
Minimum of Months | 0.135698E+10 | 1249.73 | 0.380401E+10 | 2751.42 | ||
Maximum of Months | 0.154631E+10 | 1249.73 | 0.429860E+10 | 2751.42 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.134738E+11 | 16279.94 | 02-JAN-17:40 | 0.707031E+10 | 4639.58 | 02-JAN-09:09 |
February | 0.119007E+11 | 16279.94 | 01-FEB-17:00 | 0.641452E+10 | 4639.58 | 01-FEB-09:09 |
March | 0.135182E+11 | 16279.94 | 01-MAR-17:00 | 0.724851E+10 | 4639.58 | 01-MAR-09:09 |
April | 0.125831E+11 | 14885.91 | 20-APR-16:00 | 0.688804E+10 | 4639.58 | 01-APR-09:09 |
May | 0.129839E+11 | 15103.74 | 22-MAY-16:00 | 0.715941E+10 | 4639.58 | 01-MAY-08:09 |
June | 0.122898E+11 | 15018.17 | 03-JUN-16:00 | 0.700021E+10 | 4639.58 | 01-JUN-08:09 |
July | 0.125189E+11 | 15088.79 | 17-JUL-16:00 | 0.704724E+10 | 4639.58 | 01-JUL-09:09 |
August | 0.130769E+11 | 15038.13 | 24-AUG-16:00 | 0.724851E+10 | 4639.58 | 01-AUG-08:09 |
September | 0.124789E+11 | 15289.01 | 26-SEP-16:00 | 0.688804E+10 | 4639.58 | 01-SEP-08:09 |
October | 0.127067E+11 | 15735.43 | 30-OCT-16:00 | 0.707031E+10 | 4639.58 | 02-OCT-08:09 |
November | 0.129934E+11 | 16279.94 | 06-NOV-17:30 | 0.684509E+10 | 4639.58 | 01-NOV-08:09 |
December | 0.136470E+11 | 16279.94 | 01-DEC-17:30 | 0.704724E+10 | 4639.58 | 01-DEC-09:09 |
Annual Sum or Average | 0.154171E+12 | 0.839274E+11 | ||||
Minimum of Months | 0.119007E+11 | 14885.91 | 0.641452E+10 | 4639.58 | ||
Maximum of Months | 0.136470E+11 | 16279.94 | 0.724851E+10 | 4639.58 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.174880E+10 | 1534.02 | 02-JAN-09:09 | 0.443872E+10 | 2912.71 | 02-JAN-09:09 |
February | 0.159209E+10 | 1534.02 | 01-FEB-09:09 | 0.402701E+10 | 2912.71 | 01-FEB-09:09 |
March | 0.181792E+10 | 1534.02 | 01-MAR-09:09 | 0.455059E+10 | 2912.71 | 01-MAR-09:09 |
April | 0.171453E+10 | 1534.02 | 01-APR-09:09 | 0.432429E+10 | 2912.71 | 01-APR-09:09 |
May | 0.178336E+10 | 1534.02 | 01-MAY-08:09 | 0.449465E+10 | 2912.71 | 01-MAY-08:09 |
June | 0.175416E+10 | 1534.02 | 01-JUN-08:09 | 0.439471E+10 | 2912.71 | 01-JUN-08:09 |
July | 0.174372E+10 | 1534.02 | 01-JUL-09:09 | 0.442423E+10 | 2912.71 | 01-JUL-09:09 |
August | 0.181792E+10 | 1534.02 | 01-AUG-08:09 | 0.455059E+10 | 2912.71 | 01-AUG-08:09 |
September | 0.171453E+10 | 1534.02 | 01-SEP-08:09 | 0.432429E+10 | 2912.71 | 01-SEP-08:09 |
October | 0.174880E+10 | 1534.02 | 02-OCT-08:09 | 0.443872E+10 | 2912.71 | 02-OCT-08:09 |
November | 0.169012E+10 | 1534.02 | 01-NOV-08:09 | 0.429732E+10 | 2912.71 | 01-NOV-08:09 |
December | 0.174372E+10 | 1534.02 | 01-DEC-09:09 | 0.442423E+10 | 2912.71 | 01-DEC-09:09 |
Annual Sum or Average | 0.208697E+11 | 0.526893E+11 | ||||
Minimum of Months | 0.159209E+10 | 1534.02 | 0.402701E+10 | 2912.71 | ||
Maximum of Months | 0.181792E+10 | 1534.02 | 0.455059E+10 | 2912.71 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.169457E+10 | 1485.24 | 02-JAN-09:09 | 0.666220E+09 | 437.18 | 02-JAN-09:09 |
February | 0.154270E+10 | 1485.24 | 01-FEB-09:09 | 0.604426E+09 | 437.18 | 01-FEB-09:09 |
March | 0.176147E+10 | 1485.24 | 01-MAR-09:09 | 0.683011E+09 | 437.18 | 01-MAR-09:09 |
April | 0.166132E+10 | 1485.24 | 01-APR-09:09 | 0.649045E+09 | 437.18 | 01-APR-09:09 |
May | 0.172802E+10 | 1485.24 | 01-MAY-08:09 | 0.674616E+09 | 437.18 | 01-MAY-08:09 |
June | 0.169970E+10 | 1485.24 | 01-JUN-08:09 | 0.659615E+09 | 437.18 | 01-JUN-08:09 |
July | 0.168964E+10 | 1485.24 | 01-JUL-09:09 | 0.664046E+09 | 437.18 | 01-JUL-09:09 |
August | 0.176147E+10 | 1485.24 | 01-AUG-08:09 | 0.683011E+09 | 437.18 | 01-AUG-08:09 |
September | 0.166132E+10 | 1485.24 | 01-SEP-08:09 | 0.649045E+09 | 437.18 | 01-SEP-08:09 |
October | 0.169457E+10 | 1485.24 | 02-OCT-08:09 | 0.666220E+09 | 437.18 | 02-OCT-08:09 |
November | 0.163772E+10 | 1485.24 | 01-NOV-08:09 | 0.644998E+09 | 437.18 | 01-NOV-08:09 |
December | 0.168964E+10 | 1485.24 | 01-DEC-09:09 | 0.664046E+09 | 437.18 | 01-DEC-09:09 |
Annual Sum or Average | 0.202221E+11 | 0.790830E+10 | ||||
Minimum of Months | 0.154270E+10 | 1485.24 | 0.604426E+09 | 437.18 | ||
Maximum of Months | 0.176147E+10 | 1485.24 | 0.683011E+09 | 437.18 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 6919213.84 | 2.58 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 6249612.50 | 2.58 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 6919213.84 | 2.58 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 6696013.39 | 2.58 | 01-APR-00:10 | 0.00 | 0.00 |
May | 6919213.84 | 2.58 | 01-MAY-00:10 | 0.00 | 0.00 |
June | 6696013.39 | 2.58 | 01-JUN-00:10 | 0.00 | 0.00 |
July | 6919213.84 | 2.58 | 01-JUL-00:10 | 0.00 | 0.00 |
August | 6919213.84 | 2.58 | 01-AUG-00:10 | 0.00 | 0.00 |
September | 6696013.39 | 2.58 | 01-SEP-00:10 | 0.00 | 0.00 |
October | 6919213.84 | 2.58 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 6696013.39 | 2.58 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 6919213.84 | 2.58 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 81468162.94 | ||||
Minimum of Months | 6249612.50 | 2.58 | 0.00 | 0.00 | |
Maximum of Months | 6919213.84 | 2.58 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.149153E+10 | 0.419292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129293E+09 | 30886435.15 |
February | 0.479114E+10 | 0.135698E+10 | 0.380401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175129E+09 | 1657695.54 |
March | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341049E+09 | 3299421.91 |
April | 0.518069E+10 | 0.146057E+10 | 0.408483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344152E+09 | 123170.11 |
May | 0.536353E+10 | 0.151892E+10 | 0.424576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370994E+09 | 1246471.54 |
June | 0.528933E+10 | 0.149233E+10 | 0.415135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338471E+09 | 2722130.42 |
July | 0.525489E+10 | 0.148716E+10 | 0.417924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185205E+09 | 1445106.75 |
August | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.248347E+09 | 2662071.42 |
September | 0.518069E+10 | 0.146057E+10 | 0.408483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175170E+09 | 1433949.88 |
October | 0.524694E+10 | 0.149153E+10 | 0.419292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137492E+09 | 2196092.99 |
November | 0.504819E+10 | 0.144192E+10 | 0.405935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108323E+09 | 8884895.79 |
December | 0.525489E+10 | 0.148716E+10 | 0.417924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89208978.01 | 43245778.88 |
Annual Sum or Average | 0.628175E+11 | 0.177813E+11 | 0.497716E+11 | 0.264283E+10 | 99803220.37 | ||||
Minimum of Months | 0.479114E+10 | 0.135698E+10 | 0.380401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89208978.01 | 123170.11 |
Maximum of Months | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370994E+09 | 43245778.88 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.134738E+11 | 0.707031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82711663.14 | 68280200.43 |
February | 0.201852E+11 | 0.119007E+11 | 0.641452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108797E+09 | 21387875.82 |
March | 0.230879E+11 | 0.135182E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179030E+09 | 42060019.62 |
April | 0.218263E+11 | 0.125831E+11 | 0.688804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179911E+09 | 6222138.84 |
May | 0.225967E+11 | 0.129839E+11 | 0.715941E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211256E+09 | 17872033.71 |
June | 0.222841E+11 | 0.122898E+11 | 0.700021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184236E+09 | 19051888.13 |
July | 0.221389E+11 | 0.125189E+11 | 0.704724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116246E+09 | 17828276.72 |
August | 0.230879E+11 | 0.130769E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139900E+09 | 28813808.29 |
September | 0.218263E+11 | 0.124789E+11 | 0.688804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102454E+09 | 17169436.37 |
October | 0.221054E+11 | 0.127067E+11 | 0.707031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83635122.42 | 26996467.37 |
November | 0.212681E+11 | 0.129934E+11 | 0.684509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66583714.70 | 35340552.06 |
December | 0.221389E+11 | 0.136470E+11 | 0.704724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63538793.76 | 77419178.57 |
Annual Sum or Average | 0.264651E+12 | 0.154171E+12 | 0.839274E+11 | 0.151830E+10 | 0.378442E+09 | ||||
Minimum of Months | 0.201852E+11 | 0.119007E+11 | 0.641452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63538793.76 | 6222138.84 |
Maximum of Months | 0.230879E+11 | 0.136470E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211256E+09 | 77419178.57 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.174880E+10 | 0.443872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54995897.64 | 14456741.50 |
February | 0.190200E+10 | 0.159209E+10 | 0.402701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74607224.43 | 1048507.50 |
March | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145569E+09 | 1729986.00 |
April | 0.205665E+10 | 0.171453E+10 | 0.432429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148204E+09 | 70142.71 |
May | 0.212923E+10 | 0.178336E+10 | 0.449465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160521E+09 | 573422.06 |
June | 0.209978E+10 | 0.175416E+10 | 0.439471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147070E+09 | 1150167.84 |
July | 0.208610E+10 | 0.174372E+10 | 0.442423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 80316715.25 | 634021.14 |
August | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107288E+09 | 1196666.75 |
September | 0.205665E+10 | 0.171453E+10 | 0.432429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75303476.13 | 704985.10 |
October | 0.208295E+10 | 0.174880E+10 | 0.443872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58845046.19 | 1157280.84 |
November | 0.200405E+10 | 0.169012E+10 | 0.429732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46222118.32 | 4302820.99 |
December | 0.208610E+10 | 0.174372E+10 | 0.442423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38161616.47 | 19879661.79 |
Annual Sum or Average | 0.249375E+11 | 0.208697E+11 | 0.526893E+11 | 0.113710E+10 | 46904404.23 | ||||
Minimum of Months | 0.190200E+10 | 0.159209E+10 | 0.402701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38161616.47 | 70142.71 |
Maximum of Months | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160521E+09 | 19879661.79 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.169457E+10 | 0.666220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55265626.98 | 14073589.70 |
February | 0.190200E+10 | 0.154270E+10 | 0.604426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 74966383.83 | 900523.93 |
March | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146634E+09 | 1560513.89 |
April | 0.205665E+10 | 0.166132E+10 | 0.649045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149108E+09 | 49927.51 |
May | 0.212923E+10 | 0.172802E+10 | 0.674616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161283E+09 | 493743.17 |
June | 0.209978E+10 | 0.169970E+10 | 0.659615E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147825E+09 | 1067960.13 |
July | 0.208610E+10 | 0.168964E+10 | 0.664046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80645935.32 | 548608.53 |
August | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107916E+09 | 1131725.09 |
September | 0.205665E+10 | 0.166132E+10 | 0.649045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 75687086.81 | 639618.60 |
October | 0.208295E+10 | 0.169457E+10 | 0.666220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59130411.10 | 1045343.71 |
November | 0.200405E+10 | 0.163772E+10 | 0.644998E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 46447459.80 | 4108352.49 |
December | 0.208610E+10 | 0.168964E+10 | 0.664046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 38257377.13 | 19474552.98 |
Annual Sum or Average | 0.249375E+11 | 0.202221E+11 | 0.790830E+10 | 0.114317E+10 | 45094459.72 | ||||
Minimum of Months | 0.190200E+10 | 0.154270E+10 | 0.604426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 38257377.13 | 49927.51 |
Maximum of Months | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161283E+09 | 19474552.98 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62098539.08 | 0.187748E+09 |
February | 0.00 | 6249612.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146265E+09 | 96619621.89 |
March | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349968E+09 | 55633986.29 |
April | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.434081E+09 | 17011155.26 |
May | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.476650E+09 | 41442380.58 |
June | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437434E+09 | 34863548.77 |
July | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.236028E+09 | 73316983.17 |
August | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289521E+09 | 66096901.84 |
September | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226302E+09 | 72146501.66 |
October | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119986E+09 | 96428128.46 |
November | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53862627.43 | 0.161690E+09 |
December | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30414922.11 | 0.208480E+09 |
Annual Sum or Average | 0.00 | 81468162.94 | 0.286261E+10 | 0.111148E+10 | |||||
Minimum of Months | 0.00 | 6249612.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30414922.11 | 17011155.26 |
Maximum of Months | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.476650E+09 | 0.208480E+09 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 1249.73 | 02-JAN-09:09 | 2751.42 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 363.78 | 08-JAN-19:10 | 868.65 | 07-JAN-05:00 |
February | 5888.82 | 01-FEB-15:09 | 1249.73 | 01-FEB-09:09 | 2751.42 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 465.33 | 20-FEB-19:10 | 58.68 | 26-FEB-06:40 |
March | 5888.82 | 01-MAR-15:09 | 1249.73 | 01-MAR-09:09 | 2751.42 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1018.09 | 19-MAR-18:10 | 155.38 | 03-MAR-05:40 |
April | 5888.82 | 01-APR-10:09 | 1249.73 | 01-APR-09:09 | 2751.42 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 629.19 | 02-APR-19:00 | 40.55 | 22-APR-02:40 |
May | 5888.82 | 01-MAY-14:09 | 1249.73 | 01-MAY-08:09 | 2751.42 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 806.54 | 07-MAY-18:10 | 305.76 | 08-MAY-22:00 |
June | 5888.82 | 01-JUN-14:09 | 1249.73 | 01-JUN-08:09 | 2751.42 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 755.20 | 11-JUN-19:00 | 267.92 | 20-JUN-23:20 |
July | 5888.82 | 01-JUL-10:09 | 1249.73 | 01-JUL-09:09 | 2751.42 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 415.43 | 25-JUL-21:00 | 170.87 | 19-JUL-20:40 |
August | 5888.82 | 01-AUG-14:09 | 1249.73 | 01-AUG-08:09 | 2751.42 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 606.27 | 01-AUG-21:00 | 206.72 | 23-AUG-20:05 |
September | 5888.82 | 01-SEP-14:09 | 1249.73 | 01-SEP-08:09 | 2751.42 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 358.08 | 10-SEP-15:00 | 132.67 | 15-SEP-22:10 |
October | 5888.82 | 02-OCT-14:09 | 1249.73 | 02-OCT-08:09 | 2751.42 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 515.98 | 08-OCT-18:10 | 93.06 | 23-OCT-05:00 |
November | 5888.82 | 01-NOV-14:09 | 1249.73 | 01-NOV-08:09 | 2751.42 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 216.83 | 02-NOV-21:52 | 183.16 | 25-NOV-05:00 |
December | 5888.82 | 01-DEC-15:09 | 1249.73 | 01-DEC-09:09 | 2751.42 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 245.38 | 10-DEC-19:10 | 371.35 | 21-DEC-04:40 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 1249.73 | 2751.42 | 0.00 | 0.00 | 0.00 | 0.00 | 216.83 | 40.55 | |||||
Maximum of Months | 5888.82 | 1249.73 | 2751.42 | 0.00 | 0.00 | 0.00 | 0.00 | 1018.09 | 868.65 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 16279.94 | 02-JAN-17:40 | 4639.58 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 290.40 | 08-JAN-19:02 | 1159.50 | 07-JAN-04:53 |
February | 24809.68 | 01-FEB-15:09 | 16279.94 | 01-FEB-17:00 | 4639.58 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 372.56 | 20-FEB-19:02 | 114.00 | 20-FEB-06:53 |
March | 24809.68 | 01-MAR-15:09 | 16279.94 | 01-MAR-17:00 | 4639.58 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.69 | 19-MAR-18:02 | 224.62 | 14-MAR-22:00 |
April | 24809.68 | 01-APR-10:09 | 14885.91 | 20-APR-16:00 | 4639.58 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 482.72 | 02-APR-18:02 | 99.82 | 13-APR-05:00 |
May | 24809.68 | 01-MAY-14:09 | 15103.74 | 22-MAY-16:00 | 4639.58 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 643.51 | 07-MAY-18:02 | 410.44 | 08-MAY-22:00 |
June | 24809.68 | 01-JUN-14:09 | 15018.17 | 03-JUN-16:00 | 4639.58 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 598.81 | 11-JUN-18:02 | 458.67 | 20-JUN-23:00 |
July | 24809.68 | 01-JUL-10:09 | 15088.79 | 17-JUL-16:00 | 4639.58 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 326.98 | 25-JUL-20:03 | 136.23 | 19-JUL-21:20 |
August | 24809.68 | 01-AUG-14:09 | 15038.13 | 24-AUG-16:00 | 4639.58 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 413.14 | 01-AUG-20:02 | 253.84 | 04-AUG-03:00 |
September | 24809.68 | 01-SEP-14:09 | 15289.01 | 26-SEP-16:00 | 4639.58 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 293.08 | 10-SEP-15:00 | 244.82 | 15-SEP-22:00 |
October | 24809.68 | 02-OCT-14:09 | 15735.43 | 30-OCT-16:00 | 4639.58 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 407.67 | 08-OCT-18:02 | 139.38 | 23-OCT-23:00 |
November | 24809.68 | 01-NOV-14:09 | 16279.94 | 06-NOV-17:30 | 4639.58 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 172.08 | 10-NOV-13:00 | 197.75 | 25-NOV-04:53 |
December | 24809.68 | 01-DEC-15:09 | 16279.94 | 01-DEC-17:30 | 4639.58 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 200.57 | 09-DEC-14:00 | 376.12 | 21-DEC-04:55 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 14885.91 | 4639.58 | 0.00 | 0.00 | 0.00 | 0.00 | 172.08 | 99.82 | |||||
Maximum of Months | 24809.68 | 16279.94 | 4639.58 | 0.00 | 0.00 | 0.00 | 0.00 | 811.69 | 1159.50 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1534.02 | 02-JAN-09:09 | 2912.71 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 157.99 | 08-JAN-19:10 | 454.09 | 07-JAN-05:00 |
February | 2337.76 | 01-FEB-15:09 | 1534.02 | 01-FEB-09:09 | 2912.71 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 201.65 | 20-FEB-19:10 | 36.99 | 24-FEB-01:00 |
March | 2337.76 | 01-MAR-15:09 | 1534.02 | 01-MAR-09:09 | 2912.71 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 441.17 | 19-MAR-18:10 | 84.84 | 14-MAR-22:00 |
April | 2337.76 | 01-APR-10:09 | 1534.02 | 01-APR-09:09 | 2912.71 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 272.63 | 02-APR-19:00 | 21.21 | 22-APR-02:40 |
May | 2337.76 | 01-MAY-14:09 | 1534.02 | 01-MAY-08:09 | 2912.71 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 350.20 | 07-MAY-18:10 | 141.83 | 08-MAY-22:00 |
June | 2337.76 | 01-JUN-14:09 | 1534.02 | 01-JUN-08:09 | 2912.71 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 327.27 | 11-JUN-19:00 | 118.48 | 20-JUN-23:20 |
July | 2337.76 | 01-JUL-10:09 | 1534.02 | 01-JUL-09:09 | 2912.71 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 179.95 | 25-JUL-20:30 | 72.39 | 19-JUL-20:40 |
August | 2337.76 | 01-AUG-14:09 | 1534.02 | 01-AUG-08:09 | 2912.71 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 262.70 | 01-AUG-21:00 | 95.80 | 23-AUG-20:05 |
September | 2337.76 | 01-SEP-14:09 | 1534.02 | 01-SEP-08:09 | 2912.71 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 155.16 | 10-SEP-15:00 | 75.83 | 15-SEP-22:00 |
October | 2337.76 | 02-OCT-14:09 | 1534.02 | 02-OCT-08:09 | 2912.71 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 223.57 | 08-OCT-18:10 | 50.10 | 23-OCT-04:55 |
November | 2337.76 | 01-NOV-14:09 | 1534.02 | 01-NOV-08:09 | 2912.71 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 93.76 | 02-NOV-20:10 | 86.21 | 25-NOV-05:00 |
December | 2337.76 | 01-DEC-15:09 | 1534.02 | 01-DEC-09:09 | 2912.71 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 106.31 | 10-DEC-19:10 | 177.46 | 21-DEC-05:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1534.02 | 2912.71 | 0.00 | 0.00 | 0.00 | 0.00 | 93.76 | 21.21 | |||||
Maximum of Months | 2337.76 | 1534.02 | 2912.71 | 0.00 | 0.00 | 0.00 | 0.00 | 441.17 | 454.09 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1485.24 | 02-JAN-09:09 | 437.18 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 158.00 | 08-JAN-19:10 | 428.98 | 07-JAN-05:00 |
February | 2337.76 | 01-FEB-15:09 | 1485.24 | 01-FEB-09:09 | 437.18 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 201.65 | 20-FEB-19:10 | 32.41 | 24-FEB-01:00 |
March | 2337.76 | 01-MAR-15:09 | 1485.24 | 01-MAR-09:09 | 437.18 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 441.16 | 19-MAR-18:10 | 76.34 | 14-MAR-22:00 |
April | 2337.76 | 01-APR-10:09 | 1485.24 | 01-APR-09:09 | 437.18 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 272.66 | 02-APR-19:00 | 16.51 | 22-APR-02:40 |
May | 2337.76 | 01-MAY-14:09 | 1485.24 | 01-MAY-08:09 | 437.18 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 349.99 | 07-MAY-18:10 | 127.43 | 08-MAY-22:00 |
June | 2337.76 | 01-JUN-14:09 | 1485.24 | 01-JUN-08:09 | 437.18 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 327.26 | 11-JUN-19:00 | 104.78 | 20-JUN-23:20 |
July | 2337.76 | 01-JUL-10:09 | 1485.24 | 01-JUL-09:09 | 437.18 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 179.97 | 25-JUL-20:20 | 61.48 | 19-JUL-20:40 |
August | 2337.76 | 01-AUG-14:09 | 1485.24 | 01-AUG-08:09 | 437.18 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 262.71 | 01-AUG-21:00 | 87.26 | 23-AUG-20:05 |
September | 2337.76 | 01-SEP-14:09 | 1485.24 | 01-SEP-08:09 | 437.18 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 155.16 | 10-SEP-15:00 | 66.81 | 15-SEP-22:00 |
October | 2337.76 | 02-OCT-14:09 | 1485.24 | 02-OCT-08:09 | 437.18 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 223.61 | 08-OCT-18:10 | 44.15 | 23-OCT-04:40 |
November | 2337.76 | 01-NOV-14:09 | 1485.24 | 01-NOV-08:09 | 437.18 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 93.77 | 02-NOV-20:10 | 83.52 | 25-NOV-05:00 |
December | 2337.76 | 01-DEC-15:09 | 1485.24 | 01-DEC-09:09 | 437.18 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 106.30 | 10-DEC-19:10 | 172.82 | 21-DEC-05:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1485.24 | 437.18 | 0.00 | 0.00 | 0.00 | 0.00 | 93.77 | 16.51 | |||||
Maximum of Months | 2337.76 | 1485.24 | 437.18 | 0.00 | 0.00 | 0.00 | 0.00 | 441.16 | 428.98 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 827.32 | 04-JAN-12:03 | 1478.14 | 24-JAN-08:61 |
February | 0.00 | 01-FEB-00:10 | 2.58 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1193.18 | 26-FEB-12:02 | 1050.67 | 21-FEB-09:53 |
March | 0.00 | 01-MAR-00:10 | 2.58 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2459.94 | 19-MAR-11:02 | 976.90 | 14-MAR-11:03 |
April | 0.00 | 01-APR-00:10 | 2.58 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1931.42 | 13-APR-11:02 | 1173.72 | 14-APR-15:53 |
May | 0.00 | 01-MAY-00:10 | 2.58 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3078.08 | 05-MAY-11:01 | 1834.21 | 21-MAY-12:52 |
June | 0.00 | 01-JUN-00:10 | 2.58 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1961.28 | 16-JUN-11:02 | 1532.49 | 30-JUN-12:53 |
July | 0.00 | 01-JUL-00:10 | 2.58 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1439.64 | 01-JUL-11:02 | 1337.78 | 03-JUL-12:53 |
August | 0.00 | 01-AUG-00:10 | 2.58 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2005.64 | 16-AUG-11:02 | 1377.77 | 25-AUG-11:02 |
September | 0.00 | 01-SEP-00:10 | 2.58 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1342.97 | 30-SEP-11:02 | 1602.53 | 15-SEP-16:53 |
October | 0.00 | 01-OCT-00:10 | 2.58 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1307.93 | 27-OCT-11:02 | 1066.08 | 29-OCT-16:53 |
November | 0.00 | 01-NOV-00:10 | 2.58 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 796.12 | 18-NOV-12:55 | 1002.52 | 25-NOV-08:62 |
December | 0.00 | 01-DEC-00:10 | 2.58 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.20 | 11-DEC-12:03 | 1135.26 | 21-DEC-08:61 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.20 | 976.90 | ||||
Maximum of Months | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3078.08 | 1834.21 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 33370.92 | 15-JAN-19:08 | 0.00 | 443.90 | 2269.08 | 0.00 | 0.00 | 0.00 | 0.00 | 157.34 | 0.00 |
February | 34120.12 | 24-FEB-21:07 | 0.00 | 2130.70 | 3630.52 | 0.00 | 0.00 | 0.00 | 0.00 | 62.30 | 0.00 |
March | 32969.01 | 21-MAR-20:06 | 0.00 | 1775.58 | 3025.44 | 0.00 | 0.00 | 0.00 | 0.00 | 273.33 | 0.00 |
April | 32623.66 | 22-APR-00:43 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 | 0.00 |
May | 33298.00 | 11-MAY-01:23 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.07 |
June | 33594.18 | 27-JUN-02:63 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 |
July | 34382.87 | 20-JUL-01:23 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 33591.08 | 24-AUG-02:63 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.28 |
September | 32529.54 | 10-SEP-03:03 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 32315.22 | 09-OCT-03:23 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 14.90 | 0.00 |
November | 31288.78 | 15-NOV-02:23 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 33.69 | 0.00 |
December | 33968.22 | 20-DEC-21:10 | 0.00 | 1420.46 | 2420.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.81 |
Annual Sum or Average | |||||||||||
Minimum of Months | 31288.78 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 34382.87 | 0.00 | 2130.70 | 3630.52 | 0.00 | 0.00 | 0.00 | 0.00 | 273.33 | 86.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 110354.09 | 28-JAN-07:03 | 12404.84 | 1378.20 | 6186.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.80 |
February | 118239.82 | 24-FEB-07:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.87 |
March | 112230.24 | 21-MAR-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.05 |
April | 107654.31 | 27-APR-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 |
May | 101891.97 | 31-MAY-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.08 |
June | 102997.14 | 20-JUN-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.19 |
July | 107253.56 | 31-JUL-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.55 |
August | 101604.10 | 16-AUG-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.71 |
September | 101825.53 | 14-SEP-05:03 | 0.00 | 1378.20 | 4081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 |
October | 95638.79 | 05-OCT-05:03 | 0.00 | 1033.65 | 3060.99 | 0.00 | 0.00 | 0.00 | 0.00 | 3.21 | 0.00 |
November | 107283.35 | 25-NOV-07:03 | 12404.84 | 1378.20 | 6186.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.89 |
December | 104328.41 | 27-DEC-07:03 | 9303.63 | 1033.65 | 6186.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.91 |
Annual Sum or Average | |||||||||||
Minimum of Months | 95638.79 | 0.00 | 1033.65 | 3060.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 118239.82 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 3.21 | 29.89 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18827.13 | 23-JAN-23:43 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.85 |
February | 18884.18 | 24-FEB-21:05 | 0.00 | 2045.36 | 3843.35 | 0.00 | 0.00 | 0.00 | 0.00 | 24.89 | 0.00 |
March | 18235.31 | 03-MAR-01:43 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 |
April | 16836.69 | 22-APR-00:43 | 0.00 | 97.40 | 1441.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2.16 | 0.00 |
May | 16957.73 | 10-MAY-20:08 | 0.00 | 1363.58 | 2562.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.59 |
June | 16637.43 | 27-JUN-01:23 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 17109.34 | 20-JUL-00:03 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.68 |
August | 16999.76 | 24-AUG-01:23 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16820.36 | 29-SEP-02:43 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 | 0.00 |
October | 17158.82 | 11-OCT-02:63 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 | 0.00 |
November | 18136.27 | 25-NOV-00:23 | 0.00 | 97.40 | 1441.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.93 |
December | 19351.39 | 20-DEC-21:08 | 0.00 | 1363.58 | 2562.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.04 |
Annual Sum or Average | |||||||||||
Minimum of Months | 16637.43 | 0.00 | 97.40 | 1441.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19351.39 | 0.00 | 2045.36 | 3843.35 | 0.00 | 0.00 | 0.00 | 0.00 | 24.89 | 44.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16482.58 | 23-JAN-23:43 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.41 |
February | 15994.91 | 24-FEB-21:05 | 0.00 | 2045.36 | 576.86 | 0.00 | 0.00 | 0.00 | 0.00 | 25.55 | 0.00 |
March | 15562.85 | 03-MAR-01:43 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 | 0.00 |
April | 14123.75 | 22-APR-00:43 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 3.47 | 0.00 |
May | 14071.17 | 10-MAY-20:08 | 0.00 | 1363.58 | 384.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.39 |
June | 14069.48 | 20-JUN-04:03 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 | 0.00 |
July | 14574.85 | 31-JUL-04:03 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 3.27 | 0.00 |
August | 14359.44 | 24-AUG-01:23 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 14268.99 | 29-SEP-02:43 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.94 | 0.00 |
October | 14607.10 | 08-OCT-03:03 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
November | 15537.30 | 25-NOV-01:03 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 2.43 | 0.00 |
December | 16480.98 | 20-DEC-21:08 | 0.00 | 1363.58 | 384.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.71 |
Annual Sum or Average | |||||||||||
Minimum of Months | 14069.48 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16482.58 | 0.00 | 2045.36 | 576.86 | 0.00 | 0.00 | 0.00 | 0.00 | 25.55 | 42.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.92 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.07 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.53 |
April | 0.00 | 01-APR-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.71 |
May | 0.00 | 01-MAY-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
June | 0.00 | 01-JUN-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.24 |
July | 0.00 | 01-JUL-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 |
August | 0.00 | 01-AUG-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.11 |
September | 0.00 | 01-SEP-00:03 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.95 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.21 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.02 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.47 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 | |
Maximum of Months | 0.00 | 0.00 | 7.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.53 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.108087E+12 | 88633.02 | 04-JAN-15:00 | 0.714374E+10 | 4789.88 | 10-JAN-12:20 |
February | 0.103419E+12 | 92670.21 | 13-FEB-15:00 | 0.645534E+10 | 4788.66 | 01-FEB-12:30 |
March | 0.121672E+12 | 96018.38 | 28-MAR-14:00 | 0.716238E+10 | 4784.07 | 02-MAR-12:39 |
April | 0.124949E+12 | 100886.17 | 01-APR-15:39 | 0.686722E+10 | 4775.30 | 03-APR-11:39 |
May | 0.133998E+12 | 111025.25 | 06-MAY-14:00 | 0.706256E+10 | 4766.88 | 02-MAY-11:50 |
June | 0.134073E+12 | 111846.44 | 13-JUN-14:00 | 0.683059E+10 | 4759.26 | 01-JUN-11:20 |
July | 0.114781E+12 | 93322.02 | 15-JUL-15:00 | 0.700395E+10 | 4755.79 | 31-JUL-11:30 |
August | 0.124590E+12 | 100041.44 | 11-AUG-14:50 | 0.706653E+10 | 4760.70 | 31-AUG-11:00 |
September | 0.118474E+12 | 97403.54 | 06-SEP-14:00 | 0.683740E+10 | 4768.26 | 29-SEP-11:20 |
October | 0.113898E+12 | 93421.47 | 16-OCT-14:00 | 0.707729E+10 | 4777.68 | 31-OCT-11:39 |
November | 0.108988E+12 | 89554.01 | 14-NOV-15:00 | 0.687585E+10 | 4784.49 | 30-NOV-12:20 |
December | 0.107986E+12 | 88031.38 | 30-DEC-15:00 | 0.713917E+10 | 4789.33 | 28-DEC-12:20 |
Annual Sum or Average | 0.141492E+13 | 0.835220E+11 | ||||
Minimum of Months | 0.103419E+12 | 88031.38 | 0.645534E+10 | 4755.79 | ||
Maximum of Months | 0.134073E+12 | 111846.44 | 0.716238E+10 | 4789.88 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.184156E+11 | 0.349050E+10 | 0.163682E+11 | 0.00 | 0.127053E+11 | 0.00 | 0.00 | 0.571077E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.163987E+11 | 0.308609E+10 | 0.148500E+11 | 0.00 | 0.121812E+11 | 0.00 | 0.00 | 0.569029E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186508E+11 | 0.327407E+10 | 0.167807E+11 | 0.00 | 0.143172E+11 | 0.00 | 0.00 | 0.686495E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.174262E+11 | 0.306510E+10 | 0.159462E+11 | 0.00 | 0.151436E+11 | 0.00 | 0.00 | 0.733678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.180211E+11 | 0.309202E+10 | 0.165744E+11 | 0.00 | 0.165404E+11 | 0.00 | 0.00 | 0.797702E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.172427E+11 | 0.294374E+10 | 0.162059E+11 | 0.00 | 0.168645E+11 | 0.00 | 0.00 | 0.808166E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.174463E+11 | 0.307584E+10 | 0.163148E+11 | 0.00 | 0.136046E+11 | 0.00 | 0.00 | 0.643396E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.182095E+11 | 0.313045E+10 | 0.167807E+11 | 0.00 | 0.152298E+11 | 0.00 | 0.00 | 0.712399E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.173220E+11 | 0.313792E+10 | 0.159462E+11 | 0.00 | 0.143883E+11 | 0.00 | 0.00 | 0.676792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.176485E+11 | 0.335902E+10 | 0.163682E+11 | 0.00 | 0.135900E+11 | 0.00 | 0.00 | 0.629325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177698E+11 | 0.337116E+10 | 0.158468E+11 | 0.00 | 0.128116E+11 | 0.00 | 0.00 | 0.591887E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.185745E+11 | 0.352195E+10 | 0.163148E+11 | 0.00 | 0.126666E+11 | 0.00 | 0.00 | 0.569087E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.213126E+12 | 0.385479E+11 | 0.194297E+12 | 0.170043E+12 | 0.00 | 0.798903E+12 | |||||||
Minimum of Months | 0.163987E+11 | 0.294374E+10 | 0.148500E+11 | 0.00 | 0.121812E+11 | 0.00 | 0.00 | 0.569029E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.186508E+11 | 0.352195E+10 | 0.167807E+11 | 0.00 | 0.168645E+11 | 0.00 | 0.00 | 0.808166E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.714374E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.645534E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.716238E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.686722E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.706256E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.683059E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.700395E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.706653E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.683740E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.707729E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.687585E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.713917E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.835220E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.645534E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.716238E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 20551.52 | 02-JAN-17:40 | 3371.20 | 01-JAN-06:10 | 10740.89 | 02-JAN-09:09 | 0.00 | 10362.01 | 10-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 20551.52 | 01-FEB-17:00 | 3371.20 | 01-FEB-06:10 | 10740.89 | 01-FEB-09:09 | 0.00 | 11062.35 | 16-FEB-07:10 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 20551.52 | 01-MAR-17:00 | 3371.20 | 01-MAR-06:10 | 10740.89 | 01-MAR-09:09 | 0.00 | 11588.45 | 28-MAR-14:00 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 19157.49 | 20-APR-16:00 | 3371.20 | 01-APR-05:10 | 10740.89 | 01-APR-09:09 | 0.00 | 12552.47 | 29-APR-14:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 19375.31 | 22-MAY-16:00 | 3371.20 | 01-MAY-05:10 | 10740.89 | 01-MAY-08:09 | 0.00 | 14183.62 | 06-MAY-14:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 19289.74 | 03-JUN-16:00 | 3371.20 | 01-JUN-05:10 | 10740.89 | 01-JUN-08:09 | 0.00 | 14620.82 | 13-JUN-14:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 19360.36 | 17-JUL-16:00 | 3371.20 | 01-JUL-05:10 | 10740.89 | 01-JUL-09:09 | 0.00 | 11282.55 | 02-JUL-08:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 19309.71 | 24-AUG-16:00 | 3371.20 | 01-AUG-05:10 | 10740.89 | 01-AUG-08:09 | 0.00 | 12922.18 | 11-AUG-14:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 19560.59 | 26-SEP-16:00 | 3371.20 | 01-SEP-05:10 | 10740.89 | 01-SEP-08:09 | 0.00 | 12776.66 | 30-SEP-10:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 20007.00 | 30-OCT-16:00 | 3371.20 | 01-OCT-05:10 | 10740.89 | 02-OCT-08:09 | 0.00 | 11504.49 | 16-OCT-14:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 20551.52 | 06-NOV-17:30 | 3371.20 | 01-NOV-05:10 | 10740.89 | 01-NOV-08:09 | 0.00 | 11321.00 | 11-NOV-09:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 20551.52 | 01-DEC-17:30 | 3371.20 | 01-DEC-17:30 | 10740.89 | 01-DEC-09:09 | 0.00 | 11282.55 | 10-DEC-09:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 19157.49 | 3371.20 | 10740.89 | 0.00 | 10362.01 | 0.00 | 0.00 | |||||
Maximum of Months | 20551.52 | 3371.20 | 10740.89 | 0.00 | 14620.82 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 50004.55 | 04-JAN-15:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 54356.45 | 28-FEB-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 57967.14 | 28-MAR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 61781.57 | 01-APR-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 69959.64 | 06-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 70738.80 | 13-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 54610.39 | 15-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 61457.18 | 11-AUG-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 60469.31 | 30-SEP-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 55156.64 | 16-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 51727.09 | 18-NOV-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 49821.81 | 30-DEC-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 49821.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 70738.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 88633.02 | 04-JAN-15:00 | 17917.47 | 10740.89 | 0.00 | 0.00 | 10024.94 | 0.00 | 0.00 | 49949.72 | 0.00 |
February | 92670.21 | 13-FEB-15:00 | 17165.33 | 10740.89 | 0.00 | 0.00 | 10789.95 | 0.00 | 0.00 | 53974.04 | 0.00 |
March | 96018.38 | 28-MAR-14:00 | 15721.91 | 10740.89 | 0.00 | 0.00 | 11588.45 | 0.00 | 0.00 | 57967.14 | 0.00 |
April | 100886.17 | 01-APR-15:39 | 16693.67 | 10740.89 | 0.00 | 0.00 | 12477.03 | 0.00 | 0.00 | 60974.58 | 0.00 |
May | 111025.25 | 06-MAY-14:00 | 16141.10 | 10740.89 | 0.00 | 0.00 | 14183.62 | 0.00 | 0.00 | 69959.64 | 0.00 |
June | 111846.44 | 13-JUN-14:00 | 15745.94 | 10740.89 | 0.00 | 0.00 | 14620.82 | 0.00 | 0.00 | 70738.80 | 0.00 |
July | 93322.02 | 15-JUL-15:00 | 16928.98 | 10740.89 | 0.00 | 0.00 | 11041.76 | 0.00 | 0.00 | 54610.39 | 0.00 |
August | 100041.44 | 11-AUG-14:50 | 15404.03 | 10740.89 | 0.00 | 0.00 | 12812.32 | 0.00 | 0.00 | 61084.21 | 0.00 |
September | 97403.54 | 06-SEP-14:00 | 15978.91 | 10740.89 | 0.00 | 0.00 | 12139.68 | 0.00 | 0.00 | 58544.07 | 0.00 |
October | 93421.47 | 16-OCT-14:00 | 16019.45 | 10740.89 | 0.00 | 0.00 | 11504.49 | 0.00 | 0.00 | 55156.64 | 0.00 |
November | 89554.01 | 14-NOV-15:00 | 18508.63 | 10740.89 | 0.00 | 0.00 | 10376.82 | 0.00 | 0.00 | 49927.67 | 0.00 |
December | 88031.38 | 30-DEC-15:00 | 17944.80 | 10740.89 | 0.00 | 0.00 | 10077.57 | 0.00 | 0.00 | 49268.12 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 88031.38 | 15404.03 | 10740.89 | 0.00 | 0.00 | 10024.94 | 0.00 | 0.00 | 49268.12 | 0.00 | |
Maximum of Months | 111846.44 | 18508.63 | 10740.89 | 0.00 | 0.00 | 14620.82 | 0.00 | 0.00 | 70738.80 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 4789.88 | 10-JAN-12:20 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 4788.66 | 01-FEB-12:30 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 4784.07 | 02-MAR-12:39 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 4775.30 | 03-APR-11:39 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 4766.88 | 02-MAY-11:50 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4759.26 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4755.79 | 31-JUL-11:30 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4760.70 | 31-AUG-11:00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 4768.26 | 29-SEP-11:20 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 4777.68 | 31-OCT-11:39 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 4784.49 | 30-NOV-12:20 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 4789.33 | 28-DEC-12:20 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4755.79 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4789.88 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 31.33 | 24.54 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 45.67 | 24.57 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 60.33 | 24.65 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 60.00 | 24.74 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 59.67 | 24.81 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 64.00 | 24.90 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 68.00 | 24.71 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 52.50 | 24.70 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 53.00 | 24.64 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 40.33 | 24.57 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 32.67 | 24.54 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 | 24.52 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 589.33 | 24.68 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 | 24.52 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 68.00 | 24.90 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.33 | 24.47 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.33 | 24.47 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.17 | 24.46 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.83 | 24.47 | 0.83 | 24.47 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.33 | 24.47 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 69.67 | 24.88 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 65.00 | 24.92 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 69.00 | 24.92 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 63.67 | 24.88 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 65.83 | 24.84 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 65.50 | 24.87 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 70.83 | 24.73 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 57.33 | 24.76 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 62.83 | 24.79 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 60.33 | 24.80 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 63.17 | 24.82 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 68.67 | 24.83 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 781.83 | 24.84 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 57.33 | 24.73 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 70.83 | 24.92 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 63.33 | 24.77 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 63.83 | 24.78 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 66.67 | 24.77 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 60.33 | 24.74 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 59.17 | 24.74 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 61.33 | 24.75 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 62.50 | 24.63 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 50.33 | 24.66 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 56.00 | 24.70 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 54.17 | 24.69 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 | 24.72 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 59.83 | 24.74 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 713.83 | 24.73 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 50.33 | 24.63 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 66.67 | 24.78 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 407.17 | 23.89 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 375.67 | 23.89 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 421.67 | 23.89 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 405.00 | 23.89 | 0.00 | 0.00 |
May | 15.67 | 23.89 | 418.00 | 23.89 | 15.67 | 23.89 |
June | 0.00 | 0.00 | 408.00 | 23.89 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 415.00 | 23.89 | 0.00 | 0.00 |
August | 21.00 | 23.89 | 422.00 | 23.89 | 21.00 | 23.89 |
September | 4.83 | 23.89 | 405.00 | 23.89 | 4.83 | 23.89 |
October | 15.33 | 23.89 | 414.00 | 23.89 | 15.33 | 23.89 |
November | 0.00 | 0.00 | 398.83 | 23.89 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 411.17 | 23.89 | 0.00 | 0.00 |
Annual Sum or Average | 56.83 | 23.89 | 4901.50 | 23.89 | 56.83 | 23.89 |
Minimum of Months | 0.00 | 0.00 | 375.67 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 21.00 | 23.89 | 422.00 | 23.89 | 21.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 29.50 | 23.93 | 414.00 | 23.89 | 29.50 | 23.93 |
February | 15.83 | 23.96 | 376.00 | 23.89 | 15.83 | 23.96 |
March | 20.67 | 23.98 | 422.00 | 23.89 | 20.67 | 23.98 |
April | 52.00 | 23.93 | 405.00 | 23.89 | 52.00 | 23.93 |
May | 141.33 | 23.91 | 418.00 | 23.90 | 141.33 | 23.91 |
June | 108.33 | 23.91 | 408.00 | 23.90 | 108.33 | 23.91 |
July | 63.17 | 23.92 | 415.00 | 23.89 | 63.17 | 23.92 |
August | 178.33 | 23.90 | 422.00 | 23.89 | 178.33 | 23.90 |
September | 127.67 | 23.91 | 405.00 | 23.89 | 127.67 | 23.91 |
October | 153.00 | 23.90 | 414.00 | 23.89 | 153.00 | 23.90 |
November | 74.00 | 23.91 | 399.00 | 23.89 | 74.00 | 23.91 |
December | 50.17 | 23.92 | 415.00 | 23.89 | 50.17 | 23.92 |
Annual Sum or Average | 1014.00 | 23.91 | 4913.00 | 23.89 | 1014.00 | 23.91 |
Minimum of Months | 15.83 | 23.90 | 376.00 | 23.89 | 15.83 | 23.90 |
Maximum of Months | 178.33 | 23.98 | 422.00 | 23.90 | 178.33 | 23.98 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 414.00 | 23.89 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 376.00 | 23.89 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 422.00 | 23.89 | 0.00 | 0.00 |
April | 2.67 | 23.89 | 405.00 | 23.89 | 2.67 | 23.89 |
May | 21.67 | 23.89 | 418.00 | 23.89 | 21.67 | 23.89 |
June | 8.83 | 23.89 | 408.00 | 23.89 | 8.83 | 23.89 |
July | 2.33 | 23.89 | 415.00 | 23.89 | 2.33 | 23.89 |
August | 32.50 | 23.89 | 422.00 | 23.89 | 32.50 | 23.89 |
September | 9.00 | 23.89 | 405.00 | 23.89 | 9.00 | 23.89 |
October | 17.33 | 23.89 | 414.00 | 23.89 | 17.33 | 23.89 |
November | 0.00 | 0.00 | 399.00 | 23.89 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 415.00 | 23.89 | 0.00 | 0.00 |
Annual Sum or Average | 94.33 | 23.89 | 4913.00 | 23.89 | 94.33 | 23.89 |
Minimum of Months | 0.00 | 0.00 | 376.00 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 32.50 | 23.89 | 422.00 | 23.89 | 32.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 23.89 | 413.83 | 23.89 | 1.50 | 23.89 |
February | 0.00 | 0.00 | 376.00 | 23.89 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 422.00 | 23.89 | 0.00 | 0.00 |
April | 8.67 | 23.89 | 405.00 | 23.89 | 8.67 | 23.89 |
May | 64.67 | 23.89 | 418.00 | 23.89 | 64.67 | 23.89 |
June | 32.17 | 23.89 | 408.00 | 23.89 | 32.17 | 23.89 |
July | 11.00 | 23.89 | 415.00 | 23.89 | 11.00 | 23.89 |
August | 93.17 | 23.89 | 422.00 | 23.89 | 93.17 | 23.89 |
September | 41.00 | 23.89 | 405.00 | 23.89 | 41.00 | 23.89 |
October | 44.17 | 23.89 | 414.00 | 23.89 | 44.17 | 23.89 |
November | 4.17 | 23.89 | 399.00 | 23.89 | 4.17 | 23.89 |
December | 1.67 | 23.89 | 415.00 | 23.89 | 1.67 | 23.89 |
Annual Sum or Average | 302.17 | 23.89 | 4912.83 | 23.89 | 302.17 | 23.89 |
Minimum of Months | 0.00 | 0.00 | 376.00 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 93.17 | 23.89 | 422.00 | 23.89 | 93.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.88961 | 52.41893 | 0.54078 | 11.15809 |
February | 376.00000 | 23.88963 | 51.63602 | 0.56063 | 11.62121 |
March | 422.00000 | 23.88947 | 52.25676 | 0.58050 | 12.10076 |
April | 405.00000 | 23.88933 | 53.74838 | 0.61115 | 12.86707 |
May | 418.00000 | 23.88924 | 55.31462 | -0.1985 | 5.93493 |
June | 408.00000 | 23.88920 | 53.83928 | -0.1659 | 5.70585 |
July | 415.00000 | 23.88943 | 52.58490 | -0.2402 | 6.28651 |
August | 422.00000 | 23.88934 | 57.08278 | -0.2419 | 6.32423 |
September | 405.00000 | 23.88943 | 56.35730 | -0.2530 | 6.40412 |
October | 414.00000 | 23.88953 | 57.57185 | 0.57579 | 11.97496 |
November | 399.00000 | 23.88962 | 55.23265 | 0.56507 | 11.71629 |
December | 415.00000 | 23.88962 | 53.87014 | 0.54316 | 11.20671 |
Annual Sum or Average | 4913.00000 | 23.88945 | 54.34358 | 0.23643 | 9.41789 |
Minimum of Months | 376.00000 | 23.88920 | 51.63602 | -0.2530 | 5.70585 |
Maximum of Months | 422.00000 | 23.88963 | 57.57185 | 0.61115 | 12.86707 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.91116 | 57.02216 | 0.59737 | 12.51564 |
February | 376.00000 | 23.91408 | 56.52931 | 0.61395 | 12.94034 |
March | 422.00000 | 23.91477 | 56.77052 | 0.63066 | 13.38785 |
April | 405.00000 | 23.91576 | 59.90439 | 0.65921 | 14.16474 |
May | 418.00000 | 23.91725 | 63.25436 | -0.1731 | 5.69804 |
June | 408.00000 | 23.91690 | 62.82509 | -0.1610 | 5.61393 |
July | 415.00000 | 23.91523 | 60.49151 | -0.2165 | 6.02581 |
August | 422.00000 | 23.91580 | 64.48905 | -0.1950 | 5.87300 |
September | 405.00000 | 23.91574 | 63.38898 | -0.1939 | 5.85028 |
October | 414.00000 | 23.91504 | 64.02274 | 0.63747 | 13.56533 |
November | 399.00000 | 23.91467 | 61.38259 | 0.62458 | 13.22020 |
December | 415.00000 | 23.91138 | 58.92662 | 0.60276 | 12.65322 |
Annual Sum or Average | 4913.00000 | 23.91482 | 60.77673 | 0.28208 | 10.09489 |
Minimum of Months | 376.00000 | 23.91116 | 56.52931 | -0.2165 | 5.61393 |
Maximum of Months | 422.00000 | 23.91725 | 64.48905 | 0.65921 | 14.16474 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.88930 | 48.39181 | 0.66560 | 14.39234 |
February | 376.00000 | 23.88928 | 48.75360 | 0.67261 | 14.58386 |
March | 422.00000 | 23.88921 | 50.70831 | 0.65839 | 14.16821 |
April | 405.00000 | 23.88919 | 54.22696 | 0.66194 | 14.24187 |
May | 418.00000 | 23.88922 | 56.75449 | -0.1492 | 5.55916 |
June | 408.00000 | 23.88920 | 56.54356 | -0.1400 | 5.50121 |
July | 415.00000 | 23.88939 | 54.11915 | -0.1978 | 5.88692 |
August | 422.00000 | 23.88927 | 57.83337 | -0.1835 | 5.80586 |
September | 405.00000 | 23.88928 | 56.07999 | -0.1658 | 5.67943 |
October | 414.00000 | 23.88927 | 55.59815 | 0.65161 | 13.97209 |
November | 399.00000 | 23.88929 | 51.96246 | 0.66633 | 14.39263 |
December | 415.00000 | 23.88932 | 49.45098 | 0.66746 | 14.43802 |
Annual Sum or Average | 4913.00000 | 23.88927 | 53.40319 | 0.31362 | 10.67969 |
Minimum of Months | 376.00000 | 23.88919 | 48.39181 | -0.1978 | 5.50121 |
Maximum of Months | 422.00000 | 23.88939 | 57.83337 | 0.67261 | 14.58386 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.88927 | 49.59606 | 0.64987 | 13.94324 |
February | 376.00000 | 23.88925 | 49.85316 | 0.65677 | 14.13096 |
March | 422.00000 | 23.88921 | 52.25176 | 0.64404 | 13.76677 |
April | 405.00000 | 23.88928 | 56.11923 | 0.65159 | 13.94944 |
May | 418.00000 | 23.88930 | 58.99733 | -0.1669 | 5.66356 |
June | 408.00000 | 23.88927 | 58.57806 | -0.1577 | 5.60245 |
July | 415.00000 | 23.88941 | 56.47070 | -0.2159 | 6.03431 |
August | 422.00000 | 23.88934 | 60.64944 | -0.1979 | 5.90526 |
September | 405.00000 | 23.88935 | 58.46306 | -0.1830 | 5.78982 |
October | 414.00000 | 23.88932 | 58.18905 | 0.64419 | 13.75722 |
November | 399.00000 | 23.88928 | 53.69649 | 0.65387 | 14.03355 |
December | 415.00000 | 23.88929 | 50.80569 | 0.65262 | 14.01295 |
Annual Sum or Average | 4913.00000 | 23.88930 | 55.34771 | 0.29895 | 10.51280 |
Minimum of Months | 376.00000 | 23.88921 | 49.59606 | -0.2159 | 5.60245 |
Maximum of Months | 422.00000 | 23.88941 | 60.64944 | 0.65677 | 14.13096 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.356424E+11 | 0.908454E+10 | 646.56 | 0.256126E+11 | 0.100298E+11 | 0.00 | 1.00 | 02-JAN-21:08 | 0.00 | 01-JAN-00:03 | 48329.57 | 09-JAN-21:08 | 37617.42 | 15-JAN-19:08 | 14794.16 | 09-JAN-21:08 | 11369.15 | 08-JAN-19:08 | 0.00 | 01-JAN-00:03 |
February | 0.361659E+11 | 0.923276E+10 | 592.32 | 0.263726E+11 | 0.979328E+10 | 0.00 | 1.00 | 01-FEB-21:06 | 0.00 | 01-FEB-00:12 | 48038.58 | 15-FEB-21:06 | 38225.29 | 24-FEB-21:07 | 14168.41 | 14-FEB-21:06 | 11451.84 | 26-FEB-19:06 | 0.00 | 01-FEB-00:10 |
March | 0.449090E+11 | 0.114618E+11 | 662.60 | 0.323241E+11 | 0.125849E+11 | 0.00 | 1.00 | 01-MAR-21:08 | 0.00 | 01-MAR-00:12 | 48242.96 | 25-MAR-03:23 | 37287.72 | 13-MAR-22:03 | 14414.05 | 26-MAR-07:03 | 11533.33 | 26-MAR-18:06 | 0.00 | 01-MAR-00:10 |
April | 0.496718E+11 | 0.125743E+11 | 643.40 | 0.343537E+11 | 0.153181E+11 | 0.00 | 1.00 | 01-APR-04:03 | 0.00 | 01-APR-00:33 | 48622.88 | 20-APR-20:10 | 36614.92 | 26-APR-20:06 | 17234.56 | 20-APR-20:10 | 12092.52 | 30-APR-18:43 | 0.00 | 01-APR-00:03 |
May | 0.566263E+11 | 0.141942E+11 | 665.04 | 0.377083E+11 | 0.189181E+11 | 0.00 | 1.00 | 01-MAY-20:06 | 0.00 | 01-MAY-00:33 | 48998.67 | 19-MAY-02:63 | 36532.94 | 31-MAY-20:43 | 18594.06 | 21-MAY-18:10 | 11988.12 | 29-MAY-18:06 | 0.00 | 01-MAY-00:03 |
June | 0.599376E+11 | 0.149488E+11 | 647.43 | 0.406514E+11 | 0.192862E+11 | 0.00 | 1.00 | 01-JUN-01:23 | 0.00 | 01-JUN-00:33 | 48986.78 | 10-JUN-02:43 | 37202.76 | 07-JUN-20:42 | 17771.05 | 28-JUN-20:10 | 11847.77 | 11-JUN-18:42 | 0.00 | 01-JUN-00:03 |
July | 0.483678E+11 | 0.119783E+11 | 665.59 | 0.340835E+11 | 0.142844E+11 | 0.00 | 1.00 | 01-JUL-21:08 | 0.00 | 01-JUL-00:05 | 48528.20 | 07-JUL-20:43 | 37685.04 | 20-JUL-01:23 | 15068.56 | 07-JUL-20:08 | 11546.80 | 30-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.494424E+11 | 0.121524E+11 | 656.06 | 0.318105E+11 | 0.176319E+11 | 0.00 | 1.00 | 01-AUG-00:03 | 0.00 | 01-AUG-00:33 | 48911.84 | 06-AUG-18:43 | 36800.96 | 24-AUG-02:63 | 16677.28 | 06-AUG-18:43 | 11566.05 | 27-AUG-18:06 | 0.00 | 01-AUG-00:03 |
September | 0.453599E+11 | 0.112227E+11 | 637.99 | 0.296981E+11 | 0.156619E+11 | 0.00 | 1.00 | 01-SEP-00:03 | 0.00 | 01-SEP-00:07 | 48782.59 | 18-SEP-20:43 | 36427.35 | 12-SEP-04:03 | 16428.41 | 17-SEP-18:10 | 11593.05 | 04-SEP-18:06 | 0.00 | 01-SEP-00:03 |
October | 0.408231E+11 | 0.100755E+11 | 644.96 | 0.262478E+11 | 0.145753E+11 | 0.00 | 1.00 | 01-OCT-03:43 | 0.00 | 01-OCT-00:12 | 48901.87 | 25-OCT-20:43 | 36121.84 | 09-OCT-03:23 | 16875.43 | 25-OCT-20:43 | 11324.02 | 15-OCT-18:08 | 0.00 | 01-OCT-00:10 |
November | 0.378517E+11 | 0.941969E+10 | 625.54 | 0.253477E+11 | 0.125040E+11 | 0.00 | 1.00 | 01-NOV-20:08 | 0.00 | 01-NOV-00:33 | 48868.67 | 11-NOV-19:10 | 35085.32 | 15-NOV-03:03 | 16490.65 | 11-NOV-19:10 | 11413.40 | 19-NOV-19:06 | 0.00 | 01-NOV-00:05 |
December | 0.351655E+11 | 0.887998E+10 | 643.71 | 0.244564E+11 | 0.107091E+11 | 0.00 | 1.00 | 01-DEC-21:08 | 0.00 | 01-DEC-00:13 | 48914.05 | 09-DEC-22:10 | 37552.56 | 20-DEC-21:10 | 16255.04 | 09-DEC-22:10 | 11330.47 | 10-DEC-19:06 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.539963E+12 | 0.135225E+12 | 7731.18 | 0.368667E+12 | 0.171297E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.351655E+11 | 0.887998E+10 | 592.32 | 0.244564E+11 | 0.979328E+10 | 0.00 | 1.00 | 0.00 | 48038.58 | 35085.32 | 14168.41 | 11324.02 | 0.00 | |||||||
Maximum of Months | 0.599376E+11 | 0.149488E+11 | 665.59 | 0.406514E+11 | 0.192862E+11 | 0.00 | 1.00 | 0.00 | 48998.67 | 38225.29 | 18594.06 | 12092.52 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.133150E+12 | 0.351830E+11 | 423.00 | 0.821299E+11 | 0.510196E+11 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 205422.50 | 02-JAN-07:02 | 127287.89 | 16-JAN-09:02 | 105973.05 | 02-JAN-07:02 | 48357.97 | 11-JAN-07:02 | 0.00 | 01-JAN-00:03 |
February | 0.133258E+12 | 0.353741E+11 | 388.47 | 0.830105E+11 | 0.502474E+11 | 0.00 | 1.00 | 01-FEB-07:02 | 0.00 | 01-FEB-00:10 | 205026.24 | 16-FEB-07:02 | 129642.91 | 25-FEB-07:02 | 102676.56 | 16-FEB-07:04 | 49758.73 | 20-FEB-09:02 | 0.00 | 01-FEB-00:10 |
March | 0.163355E+12 | 0.435028E+11 | 442.07 | 0.101371E+12 | 0.619836E+11 | 0.00 | 1.00 | 01-MAR-07:02 | 0.00 | 01-MAR-00:10 | 204812.44 | 28-MAR-06:02 | 129295.67 | 14-MAR-05:03 | 100981.56 | 28-MAR-06:15 | 50416.34 | 26-MAR-08:62 | 0.00 | 01-MAR-00:10 |
April | 0.179752E+12 | 0.471089E+11 | 428.31 | 0.102815E+12 | 0.769369E+11 | 0.00 | 1.00 | 01-APR-05:03 | 0.00 | 01-APR-00:03 | 206480.34 | 15-APR-06:02 | 126749.55 | 27-APR-05:03 | 107350.46 | 15-APR-06:02 | 50509.79 | 30-APR-08:15 | 0.00 | 01-APR-00:03 |
May | 0.196888E+12 | 0.508212E+11 | 441.61 | 0.103853E+12 | 0.930348E+11 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:03 | 210074.01 | 19-MAY-06:02 | 120814.73 | 07-MAY-07:02 | 125470.92 | 22-MAY-06:06 | 52125.36 | 28-MAY-07:03 | 0.00 | 01-MAY-00:03 |
June | 0.198696E+12 | 0.512288E+11 | 431.17 | 0.104559E+12 | 0.941366E+11 | 0.00 | 1.00 | 01-JUN-05:03 | 0.00 | 01-JUN-00:03 | 209729.35 | 29-JUN-06:02 | 117500.41 | 20-JUN-05:03 | 118611.13 | 29-JUN-06:02 | 50966.36 | 18-JUN-08:15 | 0.00 | 01-JUN-00:03 |
July | 0.157550E+12 | 0.404026E+11 | 434.09 | 0.875597E+11 | 0.699905E+11 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 207132.06 | 01-JUL-06:02 | 122543.11 | 15-JUL-05:03 | 110432.45 | 01-JUL-06:02 | 49454.17 | 30-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.182722E+12 | 0.460688E+11 | 442.31 | 0.918311E+11 | 0.908908E+11 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:03 | 209186.02 | 05-AUG-06:02 | 116529.67 | 16-AUG-05:03 | 120081.44 | 21-AUG-06:03 | 50472.83 | 13-AUG-08:15 | 0.00 | 01-AUG-00:03 |
September | 0.172069E+12 | 0.435751E+11 | 425.70 | 0.889747E+11 | 0.830943E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:03 | 209432.49 | 17-SEP-08:62 | 119463.93 | 14-SEP-05:03 | 117094.71 | 17-SEP-08:62 | 50183.83 | 10-SEP-08:15 | 0.00 | 01-SEP-00:03 |
October | 0.160225E+12 | 0.403180E+11 | 429.62 | 0.818100E+11 | 0.784152E+11 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 208632.04 | 12-OCT-06:02 | 117116.85 | 05-OCT-05:03 | 116985.92 | 12-OCT-06:02 | 50003.92 | 29-OCT-08:15 | 0.00 | 01-OCT-00:10 |
November | 0.145637E+12 | 0.371478E+11 | 415.27 | 0.791841E+11 | 0.664530E+11 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:05 | 207671.75 | 12-NOV-09:02 | 118191.98 | 25-NOV-07:03 | 109634.47 | 12-NOV-09:06 | 49956.10 | 23-NOV-09:02 | 0.00 | 01-NOV-00:05 |
December | 0.135402E+12 | 0.352505E+11 | 421.37 | 0.794376E+11 | 0.559639E+11 | 0.00 | 1.00 | 01-DEC-07:03 | 0.00 | 01-DEC-00:10 | 206388.06 | 10-DEC-09:02 | 120039.68 | 03-DEC-09:02 | 107806.78 | 18-DEC-07:02 | 49895.07 | 31-DEC-09:02 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.195870E+13 | 0.505982E+12 | 5123.00 | 0.108654E+13 | 0.872167E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.133150E+12 | 0.351830E+11 | 388.47 | 0.791841E+11 | 0.502474E+11 | 0.00 | 1.00 | 0.00 | 204812.44 | 116529.67 | 100981.56 | 48357.97 | 0.00 | |||||||
Maximum of Months | 0.198696E+12 | 0.512288E+11 | 442.31 | 0.104559E+12 | 0.941366E+11 | 0.00 | 1.00 | 0.00 | 210074.01 | 129642.91 | 125470.92 | 52125.36 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.282939E+11 | 0.685511E+10 | 657.08 | 0.206091E+11 | 0.768475E+10 | 0.00 | 1.00 | 02-JAN-21:08 | 0.00 | 01-JAN-00:03 | 26747.98 | 09-JAN-21:08 | 21323.40 | 15-JAN-20:23 | 8513.15 | 09-JAN-21:08 | 6148.89 | 08-JAN-19:06 | 0.00 | 01-JAN-00:03 |
February | 0.266905E+11 | 0.654542E+10 | 596.29 | 0.194227E+11 | 0.726776E+10 | 0.00 | 1.00 | 01-FEB-05:43 | 0.00 | 01-FEB-00:12 | 26613.54 | 15-FEB-21:42 | 21582.98 | 20-FEB-22:23 | 8075.07 | 14-FEB-21:06 | 6201.60 | 26-FEB-19:06 | 0.00 | 01-FEB-00:10 |
March | 0.296660E+11 | 0.731960E+10 | 664.71 | 0.208980E+11 | 0.876796E+10 | 0.00 | 1.00 | 01-MAR-21:08 | 0.00 | 01-MAR-00:12 | 26821.89 | 25-MAR-03:23 | 20356.11 | 03-MAR-01:43 | 8857.73 | 25-MAR-03:23 | 6261.96 | 26-MAR-18:06 | 0.00 | 01-MAR-00:10 |
April | 0.297548E+11 | 0.730680E+10 | 641.16 | 0.194431E+11 | 0.103117E+11 | 0.00 | 1.00 | 01-APR-04:03 | 0.00 | 01-APR-00:33 | 27188.52 | 20-APR-20:10 | 19420.77 | 26-APR-20:06 | 10504.05 | 20-APR-20:10 | 6570.95 | 30-APR-18:43 | 0.00 | 01-APR-00:03 |
May | 0.323474E+11 | 0.785463E+10 | 663.62 | 0.198374E+11 | 0.125100E+11 | 0.00 | 1.00 | 01-MAY-20:06 | 0.00 | 01-MAY-00:33 | 27470.81 | 28-MAY-18:10 | 18753.68 | 11-MAY-03:23 | 11660.66 | 28-MAY-18:10 | 6522.10 | 29-MAY-18:06 | 0.00 | 01-MAY-00:03 |
June | 0.321127E+11 | 0.777740E+10 | 643.94 | 0.196927E+11 | 0.124200E+11 | 0.00 | 1.00 | 01-JUN-01:23 | 0.00 | 01-JUN-00:33 | 27405.30 | 03-JUN-21:08 | 18792.79 | 07-JUN-20:42 | 11209.15 | 28-JUN-20:10 | 6444.31 | 11-JUN-18:42 | 0.00 | 01-JUN-00:03 |
July | 0.266807E+11 | 0.642541E+10 | 656.89 | 0.174030E+11 | 0.927763E+10 | 0.00 | 1.00 | 01-JUL-21:08 | 0.00 | 01-JUL-00:10 | 27032.14 | 07-JUL-20:08 | 19496.57 | 13-JUL-20:08 | 9737.47 | 07-JUL-20:08 | 6281.99 | 30-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.293826E+11 | 0.698881E+10 | 657.28 | 0.175366E+11 | 0.118460E+11 | 0.00 | 1.00 | 01-AUG-00:03 | 0.00 | 01-AUG-00:07 | 27320.38 | 05-AUG-21:10 | 18955.91 | 24-AUG-01:23 | 10757.27 | 05-AUG-21:10 | 6292.76 | 27-AUG-18:06 | 0.00 | 01-AUG-00:03 |
September | 0.288162E+11 | 0.688369E+10 | 638.58 | 0.178622E+11 | 0.109540E+11 | 0.00 | 1.00 | 01-SEP-00:03 | 0.00 | 01-SEP-00:07 | 27204.48 | 18-SEP-20:10 | 19041.69 | 12-SEP-04:03 | 10302.66 | 17-SEP-18:10 | 6297.61 | 04-SEP-18:06 | 0.00 | 01-SEP-00:03 |
October | 0.284122E+11 | 0.674196E+10 | 653.65 | 0.177507E+11 | 0.106616E+11 | 0.00 | 1.00 | 01-OCT-03:43 | 0.00 | 01-OCT-00:12 | 27121.44 | 25-OCT-20:10 | 19259.52 | 11-OCT-02:63 | 10000.52 | 14-OCT-21:08 | 6145.40 | 15-OCT-18:08 | 0.00 | 01-OCT-00:10 |
November | 0.282493E+11 | 0.673895E+10 | 634.40 | 0.188130E+11 | 0.943640E+10 | 0.00 | 1.00 | 01-NOV-20:08 | 0.00 | 01-NOV-00:33 | 26968.99 | 11-NOV-19:08 | 20271.71 | 24-NOV-03:43 | 9513.25 | 12-NOV-19:08 | 6181.75 | 19-NOV-19:06 | 0.00 | 01-NOV-00:05 |
December | 0.284646E+11 | 0.682131E+10 | 657.01 | 0.201199E+11 | 0.834464E+10 | 0.00 | 1.00 | 01-DEC-21:06 | 0.00 | 01-DEC-00:13 | 27083.92 | 09-DEC-22:08 | 21157.95 | 20-DEC-21:08 | 9852.02 | 09-DEC-22:08 | 6135.61 | 10-DEC-19:06 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.348871E+12 | 0.842591E+11 | 7764.63 | 0.229388E+12 | 0.119482E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.266807E+11 | 0.642541E+10 | 596.29 | 0.174030E+11 | 0.726776E+10 | 0.00 | 1.00 | 0.00 | 26613.54 | 18753.68 | 8075.07 | 6135.61 | 0.00 | |||||||
Maximum of Months | 0.323474E+11 | 0.785463E+10 | 664.71 | 0.208980E+11 | 0.125100E+11 | 0.00 | 1.00 | 0.00 | 27470.81 | 21582.98 | 11660.66 | 6570.95 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.247883E+11 | 0.598504E+10 | 657.43 | 0.173120E+11 | 0.747637E+10 | 0.00 | 1.00 | 02-JAN-21:08 | 0.00 | 01-JAN-00:03 | 23750.66 | 09-JAN-21:08 | 18161.67 | 15-JAN-20:23 | 8621.82 | 09-JAN-21:08 | 5420.11 | 08-JAN-19:06 | 0.00 | 01-JAN-00:03 |
February | 0.235519E+11 | 0.575069E+10 | 596.66 | 0.164486E+11 | 0.710335E+10 | 0.00 | 1.00 | 01-FEB-05:43 | 0.00 | 01-FEB-00:12 | 23578.90 | 15-FEB-21:42 | 18474.44 | 20-FEB-21:42 | 8114.83 | 14-FEB-21:06 | 5464.93 | 26-FEB-19:06 | 0.00 | 01-FEB-00:10 |
March | 0.259160E+11 | 0.636530E+10 | 664.27 | 0.174505E+11 | 0.846552E+10 | 0.00 | 1.00 | 01-MAR-21:08 | 0.00 | 01-MAR-00:12 | 23726.82 | 25-MAR-03:23 | 17227.63 | 03-MAR-01:43 | 8628.99 | 25-MAR-03:23 | 5517.93 | 26-MAR-18:06 | 0.00 | 01-MAR-00:10 |
April | 0.261837E+11 | 0.637774E+10 | 640.74 | 0.162280E+11 | 0.995568E+10 | 0.00 | 1.00 | 01-APR-04:03 | 0.00 | 01-APR-00:33 | 24218.35 | 20-APR-20:10 | 16275.86 | 26-APR-20:06 | 10509.66 | 20-APR-20:10 | 5786.99 | 30-APR-18:43 | 0.00 | 01-APR-00:03 |
May | 0.287018E+11 | 0.690013E+10 | 663.43 | 0.165938E+11 | 0.121079E+11 | 0.00 | 1.00 | 01-MAY-20:06 | 0.00 | 01-MAY-00:33 | 24394.42 | 28-MAY-18:10 | 15663.28 | 11-MAY-02:43 | 11793.81 | 21-MAY-18:10 | 5744.72 | 29-MAY-18:06 | 0.00 | 01-MAY-00:03 |
June | 0.286268E+11 | 0.686156E+10 | 643.92 | 0.165563E+11 | 0.120705E+11 | 0.00 | 1.00 | 01-JUN-01:23 | 0.00 | 01-JUN-00:33 | 24413.44 | 28-JUN-20:10 | 15718.16 | 27-JUN-01:23 | 11160.31 | 28-JUN-20:10 | 5674.33 | 11-JUN-18:42 | 0.00 | 01-JUN-00:03 |
July | 0.230824E+11 | 0.553329E+10 | 656.92 | 0.142136E+11 | 0.886883E+10 | 0.00 | 1.00 | 01-JUL-21:08 | 0.00 | 01-JUL-00:10 | 24057.41 | 07-JUL-20:08 | 16493.93 | 02-JUL-23:23 | 9951.06 | 07-JUL-20:08 | 5535.32 | 30-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.255638E+11 | 0.603001E+10 | 653.80 | 0.142676E+11 | 0.112962E+11 | 0.00 | 1.00 | 01-AUG-00:03 | 0.00 | 01-AUG-00:07 | 24254.06 | 05-AUG-21:10 | 15865.39 | 24-AUG-01:23 | 10682.67 | 03-AUG-20:08 | 5543.92 | 27-AUG-18:06 | 0.00 | 01-AUG-00:03 |
September | 0.253021E+11 | 0.599769E+10 | 637.94 | 0.147516E+11 | 0.105505E+11 | 0.00 | 1.00 | 01-SEP-00:03 | 0.00 | 01-SEP-00:07 | 24227.36 | 18-SEP-20:10 | 16023.22 | 12-SEP-04:03 | 10445.72 | 18-SEP-20:10 | 5548.06 | 13-SEP-20:06 | 0.00 | 01-SEP-00:03 |
October | 0.246024E+11 | 0.579693E+10 | 650.31 | 0.144388E+11 | 0.101636E+11 | 0.00 | 1.00 | 01-OCT-03:43 | 0.00 | 01-OCT-00:12 | 24131.46 | 25-OCT-20:10 | 16225.71 | 08-OCT-03:03 | 10052.25 | 25-OCT-20:10 | 5416.75 | 15-OCT-18:08 | 0.00 | 01-OCT-00:10 |
November | 0.247974E+11 | 0.588223E+10 | 633.92 | 0.156535E+11 | 0.914398E+10 | 0.00 | 1.00 | 01-NOV-20:08 | 0.00 | 01-NOV-00:33 | 23939.79 | 30-NOV-21:08 | 17310.02 | 24-NOV-03:43 | 9442.26 | 30-NOV-21:08 | 5449.65 | 19-NOV-19:06 | 0.00 | 01-NOV-00:05 |
December | 0.249546E+11 | 0.595693E+10 | 657.02 | 0.168439E+11 | 0.811061E+10 | 0.00 | 1.00 | 01-DEC-21:06 | 0.00 | 01-DEC-00:13 | 23998.13 | 09-DEC-22:08 | 17842.41 | 26-DEC-22:23 | 9618.48 | 09-DEC-22:08 | 5407.40 | 10-DEC-19:06 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.306071E+12 | 0.734376E+11 | 7756.37 | 0.190758E+12 | 0.115313E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.230824E+11 | 0.553329E+10 | 596.66 | 0.142136E+11 | 0.710335E+10 | 0.00 | 1.00 | 0.00 | 23578.90 | 15663.28 | 8114.83 | 5407.40 | 0.00 | |||||||
Maximum of Months | 0.287018E+11 | 0.690013E+10 | 664.27 | 0.174505E+11 | 0.121079E+11 | 0.00 | 1.00 | 0.00 | 24413.44 | 18474.44 | 11793.81 | 5786.99 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 44.37 | 21.25 | 23.12 | 77.65 | 14.57 | 0.00 | 0.00 | 744.00 |
February | 51.40 | 26.78 | 24.62 | 91.88 | 15.06 | 0.00 | 0.00 | 672.00 |
March | 59.65 | 35.09 | 24.56 | 108.09 | 12.44 | 0.00 | 0.00 | 744.00 |
April | 60.42 | 34.00 | 26.42 | 110.12 | 8.67 | 0.00 | 0.00 | 720.00 |
May | 50.46 | 22.03 | 28.43 | 93.63 | 7.12 | 0.00 | 0.00 | 744.00 |
June | 54.55 | 27.09 | 27.47 | 100.71 | 7.09 | 0.00 | 0.00 | 720.00 |
July | 45.85 | 15.27 | 30.58 | 82.67 | 9.26 | 0.00 | 0.00 | 744.00 |
August | 50.70 | 21.86 | 28.84 | 89.10 | 8.68 | 0.00 | 0.00 | 744.00 |
September | 46.81 | 18.25 | 28.56 | 84.79 | 8.27 | 0.00 | 0.00 | 720.00 |
October | 42.74 | 15.18 | 27.56 | 74.62 | 8.74 | 0.00 | 0.00 | 744.00 |
November | 40.85 | 15.54 | 25.31 | 71.77 | 11.05 | 0.00 | 0.00 | 720.00 |
December | 41.18 | 18.51 | 22.67 | 71.77 | 15.09 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.05 | 22.52 | 26.52 | 88.00 | 10.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 40.85 | 15.18 | 22.67 | 71.77 | 7.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.42 | 35.09 | 30.58 | 110.12 | 15.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 665.83 | 277.73 | 388.10 | 1217.96 | 127.54 | 0.00 | 0.00 | 744.00 |
February | 565.36 | 184.24 | 381.11 | 1041.17 | 101.04 | 0.00 | 0.00 | 672.00 |
March | 385.68 | 51.60 | 334.08 | 757.92 | 66.39 | 0.00 | 0.00 | 744.00 |
April | 287.71 | 0.12 | 287.59 | 679.83 | 20.33 | 0.00 | 0.00 | 720.00 |
May | 287.91 | 0.00 | 287.91 | 709.48 | 26.91 | 0.00 | 0.00 | 744.00 |
June | 286.87 | 0.00 | 286.87 | 695.88 | 29.24 | 0.00 | 0.00 | 720.00 |
July | 295.52 | 0.00 | 295.52 | 629.71 | 58.55 | 0.00 | 0.00 | 744.00 |
August | 287.69 | 0.44 | 287.25 | 609.76 | 43.61 | 0.00 | 0.00 | 744.00 |
September | 318.42 | 10.33 | 308.10 | 666.10 | 46.29 | 0.00 | 0.00 | 720.00 |
October | 416.61 | 66.36 | 350.25 | 770.50 | 62.49 | 0.00 | 0.00 | 744.00 |
November | 541.75 | 165.22 | 376.53 | 999.89 | 86.51 | 0.00 | 0.00 | 720.00 |
December | 665.53 | 283.11 | 382.41 | 1220.44 | 145.33 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 416.49 | 86.26 | 330.23 | 832.31 | 67.82 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 286.87 | 0.00 | 286.87 | 609.76 | 20.33 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 665.83 | 283.11 | 388.10 | 1220.44 | 145.33 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 665.83 | 277.73 | 388.10 | 1211.10 | 124.10 | 0.00 | 0.00 | 744.00 |
February | 565.36 | 184.24 | 381.11 | 1034.06 | 97.46 | 0.00 | 0.00 | 672.00 |
March | 385.68 | 51.60 | 334.08 | 751.46 | 61.88 | 0.00 | 0.00 | 744.00 |
April | 287.71 | 0.12 | 287.59 | 674.64 | 17.69 | 0.00 | 0.00 | 720.00 |
May | 287.91 | 0.00 | 287.91 | 704.56 | 25.31 | 0.00 | 0.00 | 744.00 |
June | 286.87 | 0.00 | 286.87 | 690.05 | 27.45 | 0.00 | 0.00 | 720.00 |
July | 295.52 | 0.00 | 295.52 | 623.31 | 55.94 | 0.00 | 0.00 | 744.00 |
August | 287.69 | 0.44 | 287.25 | 603.79 | 40.82 | 0.00 | 0.00 | 744.00 |
September | 318.42 | 10.33 | 308.10 | 659.73 | 43.87 | 0.00 | 0.00 | 720.00 |
October | 416.61 | 66.36 | 350.25 | 765.08 | 59.45 | 0.00 | 0.00 | 744.00 |
November | 541.75 | 165.22 | 376.53 | 993.53 | 83.99 | 0.00 | 0.00 | 720.00 |
December | 665.53 | 283.11 | 382.41 | 1213.86 | 142.43 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 416.49 | 86.26 | 330.23 | 826.19 | 65.01 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 286.87 | 0.00 | 286.87 | 603.79 | 17.69 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 665.83 | 283.11 | 388.10 | 1213.86 | 142.43 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 137.00 | 57.15 | 79.86 | 218.86 | 45.37 | 0.00 | 0.00 | 744.00 |
February | 116.33 | 37.91 | 78.42 | 180.06 | 41.38 | 0.00 | 0.00 | 672.00 |
March | 79.36 | 10.62 | 68.74 | 121.17 | 32.17 | 0.00 | 0.00 | 744.00 |
April | 59.20 | 0.03 | 59.17 | 100.83 | 17.88 | 0.67 | 0.00 | 720.00 |
May | 59.24 | 0.00 | 59.24 | 104.56 | 17.94 | 72.33 | 0.00 | 744.00 |
June | 59.03 | 0.00 | 59.03 | 102.82 | 19.66 | 20.00 | 0.00 | 720.00 |
July | 60.81 | 0.00 | 60.81 | 101.06 | 24.31 | 0.00 | 0.00 | 744.00 |
August | 59.20 | 0.09 | 59.11 | 96.33 | 21.17 | 1.17 | 0.00 | 744.00 |
September | 65.52 | 2.12 | 63.40 | 106.92 | 22.84 | 0.00 | 0.00 | 720.00 |
October | 85.72 | 13.65 | 72.07 | 131.34 | 26.69 | 6.33 | 0.00 | 744.00 |
November | 111.47 | 34.00 | 77.48 | 176.71 | 33.96 | 1.33 | 0.00 | 720.00 |
December | 136.94 | 58.25 | 78.69 | 220.79 | 48.13 | 3.33 | 0.00 | 744.00 |
Annual Sum or Average | 85.70 | 17.75 | 67.95 | 138.29 | 29.26 | 105.17 | 0.00 | 8760.00 |
Minimum of Months | 59.03 | 0.00 | 59.03 | 96.33 | 17.88 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 137.00 | 58.25 | 79.86 | 220.79 | 48.13 | 72.33 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118845E+09 | 56926110.56 | 61919221.37 | 0.207981E+09 | 39016753.95 |
February | 0.124338E+09 | 64780380.55 | 59558094.37 | 0.222273E+09 | 36443144.10 |
March | 0.159765E+09 | 93990716.55 | 65774076.75 | 0.289513E+09 | 33321148.52 |
April | 0.156618E+09 | 88130069.45 | 68487493.27 | 0.285437E+09 | 22475282.51 |
May | 0.135155E+09 | 59009068.99 | 76146141.19 | 0.250782E+09 | 19065684.19 |
June | 0.141400E+09 | 70205984.06 | 71193654.75 | 0.261047E+09 | 18368154.43 |
July | 0.122808E+09 | 40893504.74 | 81914218.93 | 0.221424E+09 | 24806670.31 |
August | 0.135796E+09 | 58557859.89 | 77238042.03 | 0.238657E+09 | 23252024.28 |
September | 0.121328E+09 | 47296006.00 | 74032304.84 | 0.219774E+09 | 21434672.69 |
October | 0.114463E+09 | 40658916.89 | 73803974.13 | 0.199860E+09 | 23404392.83 |
November | 0.105888E+09 | 40287713.71 | 65600350.24 | 0.186032E+09 | 28640938.08 |
December | 0.110290E+09 | 49579786.83 | 60710458.14 | 0.192237E+09 | 40411645.43 |
Annual Sum or Average | 0.154669E+10 | 0.710316E+09 | 0.836378E+09 | 0.277502E+10 | 0.330641E+09 |
Minimum of Months | 0.105888E+09 | 40287713.71 | 59558094.37 | 0.186032E+09 | 18368154.43 |
Maximum of Months | 0.159765E+09 | 93990716.55 | 81914218.93 | 0.289513E+09 | 40411645.43 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178337E+10 | 0.743876E+09 | 0.103949E+10 | 0.326220E+10 | 0.341614E+09 |
February | 0.136771E+10 | 0.445724E+09 | 0.921991E+09 | 0.251880E+10 | 0.244429E+09 |
March | 0.103301E+10 | 0.138201E+09 | 0.894804E+09 | 0.203001E+10 | 0.177827E+09 |
April | 0.745742E+09 | 321094.83 | 0.745421E+09 | 0.176212E+10 | 52700147.43 |
May | 0.771140E+09 | 0.00 | 0.771140E+09 | 0.190026E+10 | 72064857.68 |
June | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.180373E+10 | 75792806.01 |
July | 0.791531E+09 | 0.00 | 0.791531E+09 | 0.168660E+10 | 0.156829E+09 |
August | 0.770542E+09 | 1171486.77 | 0.769370E+09 | 0.163318E+10 | 0.116805E+09 |
September | 0.825349E+09 | 26763719.06 | 0.798585E+09 | 0.172652E+10 | 0.119979E+09 |
October | 0.111584E+10 | 0.177728E+09 | 0.938113E+09 | 0.206372E+10 | 0.167366E+09 |
November | 0.140422E+10 | 0.428261E+09 | 0.975958E+09 | 0.259172E+10 | 0.224225E+09 |
December | 0.178254E+10 | 0.758288E+09 | 0.102426E+10 | 0.326883E+10 | 0.389265E+09 |
Annual Sum or Average | 0.131346E+11 | 0.272033E+10 | 0.104142E+11 | 0.262477E+11 | 0.213890E+10 |
Minimum of Months | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.163318E+10 | 52700147.43 |
Maximum of Months | 0.178337E+10 | 0.758288E+09 | 0.103949E+10 | 0.326883E+10 | 0.389265E+09 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178337E+10 | 0.743876E+09 | 0.103949E+10 | 0.324380E+10 | 0.332397E+09 |
February | 0.136771E+10 | 0.445724E+09 | 0.921991E+09 | 0.250159E+10 | 0.235780E+09 |
March | 0.103301E+10 | 0.138201E+09 | 0.894804E+09 | 0.201270E+10 | 0.165729E+09 |
April | 0.745742E+09 | 321094.83 | 0.745421E+09 | 0.174866E+10 | 45855510.88 |
May | 0.771140E+09 | 0.00 | 0.771140E+09 | 0.188710E+10 | 67791465.45 |
June | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.178862E+10 | 71141640.33 |
July | 0.791531E+09 | 0.00 | 0.791531E+09 | 0.166948E+10 | 0.149841E+09 |
August | 0.770542E+09 | 1171486.77 | 0.769370E+09 | 0.161718E+10 | 0.109320E+09 |
September | 0.825349E+09 | 26763719.06 | 0.798585E+09 | 0.171001E+10 | 0.113723E+09 |
October | 0.111584E+10 | 0.177728E+09 | 0.938113E+09 | 0.204919E+10 | 0.159236E+09 |
November | 0.140422E+10 | 0.428261E+09 | 0.975958E+09 | 0.257522E+10 | 0.217712E+09 |
December | 0.178254E+10 | 0.758288E+09 | 0.102426E+10 | 0.325120E+10 | 0.381493E+09 |
Annual Sum or Average | 0.131346E+11 | 0.272033E+10 | 0.104142E+11 | 0.260548E+11 | 0.205002E+10 |
Minimum of Months | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.161718E+10 | 45855510.88 |
Maximum of Months | 0.178337E+10 | 0.758288E+09 | 0.103949E+10 | 0.325120E+10 | 0.381493E+09 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.366954E+09 | 0.153063E+09 | 0.213891E+09 | 0.586186E+09 | 0.121531E+09 |
February | 0.281427E+09 | 91714136.05 | 0.189713E+09 | 0.435599E+09 | 0.100102E+09 |
March | 0.212556E+09 | 28436933.63 | 0.184119E+09 | 0.324534E+09 | 86172416.63 |
April | 0.153447E+09 | 66069.94 | 0.153381E+09 | 0.261344E+09 | 46334800.64 |
May | 0.158673E+09 | 0.00 | 0.158673E+09 | 0.280063E+09 | 48040821.52 |
June | 0.153002E+09 | 0.00 | 0.153002E+09 | 0.266520E+09 | 50969280.33 |
July | 0.162869E+09 | 0.00 | 0.162869E+09 | 0.270667E+09 | 65119375.14 |
August | 0.158550E+09 | 241050.46 | 0.158309E+09 | 0.257998E+09 | 56699197.91 |
September | 0.169828E+09 | 5507024.91 | 0.164320E+09 | 0.277139E+09 | 59208705.03 |
October | 0.229600E+09 | 36570073.28 | 0.193030E+09 | 0.351778E+09 | 71487426.71 |
November | 0.288938E+09 | 88120879.62 | 0.200817E+09 | 0.458032E+09 | 88016582.02 |
December | 0.366784E+09 | 0.156029E+09 | 0.210756E+09 | 0.591357E+09 | 0.128921E+09 |
Annual Sum or Average | 0.270263E+10 | 0.559748E+09 | 0.214288E+10 | 0.436122E+10 | 0.922603E+09 |
Minimum of Months | 0.153002E+09 | 0.00 | 0.153002E+09 | 0.257998E+09 | 46334800.64 |
Maximum of Months | 0.366954E+09 | 0.156029E+09 | 0.213891E+09 | 0.591357E+09 | 0.128921E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1242.42 | 233.07 | 709.95 | 340.06 | 369.89 | 0.00 | 0.00 |
February | 1470.06 | 241.03 | 822.34 | 428.44 | 393.90 | 0.00 | 0.00 |
March | 1729.47 | 199.05 | 954.39 | 561.47 | 392.92 | 0.00 | 0.00 |
April | 1761.96 | 138.74 | 966.78 | 544.01 | 422.76 | 0.00 | 0.00 |
May | 1498.10 | 113.89 | 807.38 | 352.50 | 454.88 | 0.00 | 0.00 |
June | 1611.40 | 113.38 | 872.84 | 433.37 | 439.47 | 0.00 | 0.00 |
July | 1322.72 | 148.19 | 733.62 | 244.29 | 489.33 | 0.00 | 0.00 |
August | 1425.67 | 138.90 | 811.21 | 349.81 | 461.40 | 0.00 | 0.00 |
September | 1356.63 | 132.31 | 748.94 | 291.95 | 456.99 | 0.00 | 0.00 |
October | 1193.90 | 139.81 | 683.77 | 242.88 | 440.88 | 0.00 | 0.00 |
November | 1148.35 | 176.80 | 653.63 | 248.69 | 404.94 | 0.00 | 0.00 |
December | 1148.37 | 241.41 | 658.84 | 296.18 | 362.67 | 0.00 | 0.00 |
Annual Sum or Average | 1407.92 | 167.75 | 784.73 | 360.38 | 424.34 | 0.00 | 0.00 |
Minimum of Months | 1148.35 | 113.38 | 653.63 | 242.88 | 362.67 | 0.00 | 0.00 |
Maximum of Months | 1761.96 | 241.41 | 966.78 | 561.47 | 489.33 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1217.96 | 127.54 | 665.83 | 277.73 | 388.10 | 0.00 | 0.00 |
February | 1041.17 | 101.04 | 565.36 | 184.24 | 381.11 | 0.00 | 0.00 |
March | 757.92 | 66.39 | 385.68 | 51.60 | 334.08 | 0.00 | 0.00 |
April | 679.83 | 20.33 | 287.71 | 0.12 | 287.59 | 0.00 | 0.00 |
May | 709.48 | 26.91 | 287.91 | 0.00 | 287.91 | 0.00 | 0.00 |
June | 695.88 | 29.24 | 286.87 | 0.00 | 286.87 | 0.00 | 0.00 |
July | 629.71 | 58.55 | 295.52 | 0.00 | 295.52 | 0.00 | 0.00 |
August | 609.76 | 43.61 | 287.69 | 0.44 | 287.25 | 0.00 | 0.00 |
September | 666.10 | 46.29 | 318.42 | 10.33 | 308.10 | 0.00 | 0.00 |
October | 770.50 | 62.49 | 416.61 | 66.36 | 350.25 | 0.00 | 0.00 |
November | 999.89 | 86.51 | 541.75 | 165.22 | 376.53 | 0.00 | 0.00 |
December | 1220.44 | 145.33 | 665.53 | 283.11 | 382.41 | 0.00 | 0.00 |
Annual Sum or Average | 832.31 | 67.82 | 416.49 | 86.26 | 330.23 | 0.00 | 0.00 |
Minimum of Months | 609.76 | 20.33 | 286.87 | 0.00 | 286.87 | 0.00 | 0.00 |
Maximum of Months | 1220.44 | 145.33 | 665.83 | 283.11 | 388.10 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1211.10 | 124.10 | 665.83 | 277.73 | 388.10 | 0.00 | 0.00 |
February | 1034.06 | 97.46 | 565.36 | 184.24 | 381.11 | 0.00 | 0.00 |
March | 751.46 | 61.88 | 385.68 | 51.60 | 334.08 | 0.00 | 0.00 |
April | 674.64 | 17.69 | 287.71 | 0.12 | 287.59 | 0.00 | 0.00 |
May | 704.56 | 25.31 | 287.91 | 0.00 | 287.91 | 0.00 | 0.00 |
June | 690.05 | 27.45 | 286.87 | 0.00 | 286.87 | 0.00 | 0.00 |
July | 623.31 | 55.94 | 295.52 | 0.00 | 295.52 | 0.00 | 0.00 |
August | 603.79 | 40.82 | 287.69 | 0.44 | 287.25 | 0.00 | 0.00 |
September | 659.73 | 43.87 | 318.42 | 10.33 | 308.10 | 0.00 | 0.00 |
October | 765.08 | 59.45 | 416.61 | 66.36 | 350.25 | 0.00 | 0.00 |
November | 993.53 | 83.99 | 541.75 | 165.22 | 376.53 | 0.00 | 0.00 |
December | 1213.86 | 142.43 | 665.53 | 283.11 | 382.41 | 0.00 | 0.00 |
Annual Sum or Average | 826.19 | 65.01 | 416.49 | 86.26 | 330.23 | 0.00 | 0.00 |
Minimum of Months | 603.79 | 17.69 | 286.87 | 0.00 | 286.87 | 0.00 | 0.00 |
Maximum of Months | 1213.86 | 142.43 | 665.83 | 283.11 | 388.10 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 218.86 | 45.37 | 137.00 | 57.15 | 79.86 | 0.00 | 0.00 |
February | 180.06 | 41.38 | 116.33 | 37.91 | 78.42 | 0.00 | 0.00 |
March | 121.17 | 32.17 | 79.36 | 10.62 | 68.74 | 0.00 | 0.00 |
April | 100.83 | 17.88 | 59.20 | 0.03 | 59.17 | 0.00 | 0.00 |
May | 104.56 | 17.94 | 59.24 | 0.00 | 59.24 | 0.00 | 0.00 |
June | 102.82 | 19.66 | 59.03 | 0.00 | 59.03 | 0.00 | 0.00 |
July | 101.06 | 24.31 | 60.81 | 0.00 | 60.81 | 0.00 | 0.00 |
August | 96.33 | 21.17 | 59.20 | 0.09 | 59.11 | 0.00 | 0.00 |
September | 106.92 | 22.84 | 65.52 | 2.12 | 63.40 | 0.00 | 0.00 |
October | 131.34 | 26.69 | 85.72 | 13.65 | 72.07 | 0.00 | 0.00 |
November | 176.71 | 33.96 | 111.47 | 34.00 | 77.48 | 0.00 | 0.00 |
December | 220.79 | 48.13 | 136.94 | 58.25 | 78.69 | 0.00 | 0.00 |
Annual Sum or Average | 138.29 | 29.26 | 85.70 | 17.75 | 67.95 | 0.00 | 0.00 |
Minimum of Months | 96.33 | 17.88 | 59.03 | 0.00 | 59.03 | 0.00 | 0.00 |
Maximum of Months | 220.79 | 48.13 | 137.00 | 58.25 | 79.86 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.332769E+10 | 0.624268E+09 | 0.190153E+10 | 0.910818E+09 | 0.990708E+09 | 0.00 | 0.00 |
February | 0.355638E+10 | 0.583090E+09 | 0.198942E+10 | 0.103649E+10 | 0.952930E+09 | 0.00 | 0.00 |
March | 0.463221E+10 | 0.533138E+09 | 0.255624E+10 | 0.150385E+10 | 0.105239E+10 | 0.00 | 0.00 |
April | 0.456699E+10 | 0.359605E+09 | 0.250588E+10 | 0.141008E+10 | 0.109580E+10 | 0.00 | 0.00 |
May | 0.401252E+10 | 0.305051E+09 | 0.216248E+10 | 0.944145E+09 | 0.121834E+10 | 0.00 | 0.00 |
June | 0.417675E+10 | 0.293890E+09 | 0.226239E+10 | 0.112330E+10 | 0.113910E+10 | 0.00 | 0.00 |
July | 0.354278E+10 | 0.396907E+09 | 0.196492E+10 | 0.654296E+09 | 0.131063E+10 | 0.00 | 0.00 |
August | 0.381852E+10 | 0.372032E+09 | 0.217273E+10 | 0.936926E+09 | 0.123581E+10 | 0.00 | 0.00 |
September | 0.351639E+10 | 0.342955E+09 | 0.194125E+10 | 0.756736E+09 | 0.118452E+10 | 0.00 | 0.00 |
October | 0.319775E+10 | 0.374470E+09 | 0.183141E+10 | 0.650543E+09 | 0.118086E+10 | 0.00 | 0.00 |
November | 0.297651E+10 | 0.458255E+09 | 0.169421E+10 | 0.644603E+09 | 0.104961E+10 | 0.00 | 0.00 |
December | 0.307580E+10 | 0.646586E+09 | 0.176464E+10 | 0.793277E+09 | 0.971367E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.444003E+11 | 0.529025E+10 | 0.247471E+11 | 0.113651E+11 | 0.133820E+11 | 0.00 | 0.00 |
Minimum of Months | 0.297651E+10 | 0.293890E+09 | 0.169421E+10 | 0.644603E+09 | 0.952930E+09 | 0.00 | 0.00 |
Maximum of Months | 0.463221E+10 | 0.646586E+09 | 0.255624E+10 | 0.150385E+10 | 0.131063E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.326220E+10 | 0.341614E+09 | 0.178337E+10 | 0.743876E+09 | 0.103949E+10 | 0.00 | 0.00 |
February | 0.251880E+10 | 0.244429E+09 | 0.136771E+10 | 0.445724E+09 | 0.921991E+09 | 0.00 | 0.00 |
March | 0.203001E+10 | 0.177827E+09 | 0.103301E+10 | 0.138201E+09 | 0.894804E+09 | 0.00 | 0.00 |
April | 0.176212E+10 | 52700147.43 | 0.745742E+09 | 321094.83 | 0.745421E+09 | 0.00 | 0.00 |
May | 0.190026E+10 | 72064857.68 | 0.771140E+09 | 0.00 | 0.771140E+09 | 0.00 | 0.00 |
June | 0.180373E+10 | 75792806.01 | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.00 | 0.00 |
July | 0.168660E+10 | 0.156829E+09 | 0.791531E+09 | 0.00 | 0.791531E+09 | 0.00 | 0.00 |
August | 0.163318E+10 | 0.116805E+09 | 0.770542E+09 | 1171486.77 | 0.769370E+09 | 0.00 | 0.00 |
September | 0.172652E+10 | 0.119979E+09 | 0.825349E+09 | 26763719.06 | 0.798585E+09 | 0.00 | 0.00 |
October | 0.206372E+10 | 0.167366E+09 | 0.111584E+10 | 0.177728E+09 | 0.938113E+09 | 0.00 | 0.00 |
November | 0.259172E+10 | 0.224225E+09 | 0.140422E+10 | 0.428261E+09 | 0.975958E+09 | 0.00 | 0.00 |
December | 0.326883E+10 | 0.389265E+09 | 0.178254E+10 | 0.758288E+09 | 0.102426E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.262477E+11 | 0.213890E+10 | 0.131346E+11 | 0.272033E+10 | 0.104142E+11 | 0.00 | 0.00 |
Minimum of Months | 0.163318E+10 | 52700147.43 | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.00 | 0.00 |
Maximum of Months | 0.326883E+10 | 0.389265E+09 | 0.178337E+10 | 0.758288E+09 | 0.103949E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.324380E+10 | 0.332397E+09 | 0.178337E+10 | 0.743876E+09 | 0.103949E+10 | 0.00 | 0.00 |
February | 0.250159E+10 | 0.235780E+09 | 0.136771E+10 | 0.445724E+09 | 0.921991E+09 | 0.00 | 0.00 |
March | 0.201270E+10 | 0.165729E+09 | 0.103301E+10 | 0.138201E+09 | 0.894804E+09 | 0.00 | 0.00 |
April | 0.174866E+10 | 45855510.88 | 0.745742E+09 | 321094.83 | 0.745421E+09 | 0.00 | 0.00 |
May | 0.188710E+10 | 67791465.45 | 0.771140E+09 | 0.00 | 0.771140E+09 | 0.00 | 0.00 |
June | 0.178862E+10 | 71141640.33 | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.00 | 0.00 |
July | 0.166948E+10 | 0.149841E+09 | 0.791531E+09 | 0.00 | 0.791531E+09 | 0.00 | 0.00 |
August | 0.161718E+10 | 0.109320E+09 | 0.770542E+09 | 1171486.77 | 0.769370E+09 | 0.00 | 0.00 |
September | 0.171001E+10 | 0.113723E+09 | 0.825349E+09 | 26763719.06 | 0.798585E+09 | 0.00 | 0.00 |
October | 0.204919E+10 | 0.159236E+09 | 0.111584E+10 | 0.177728E+09 | 0.938113E+09 | 0.00 | 0.00 |
November | 0.257522E+10 | 0.217712E+09 | 0.140422E+10 | 0.428261E+09 | 0.975958E+09 | 0.00 | 0.00 |
December | 0.325120E+10 | 0.381493E+09 | 0.178254E+10 | 0.758288E+09 | 0.102426E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.260548E+11 | 0.205002E+10 | 0.131346E+11 | 0.272033E+10 | 0.104142E+11 | 0.00 | 0.00 |
Minimum of Months | 0.161718E+10 | 45855510.88 | 0.743578E+09 | 0.00 | 0.743578E+09 | 0.00 | 0.00 |
Maximum of Months | 0.325120E+10 | 0.381493E+09 | 0.178337E+10 | 0.758288E+09 | 0.103949E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.586186E+09 | 0.121531E+09 | 0.366954E+09 | 0.153063E+09 | 0.213891E+09 | 0.00 | 0.00 |
February | 0.435599E+09 | 0.100102E+09 | 0.281427E+09 | 91714136.05 | 0.189713E+09 | 0.00 | 0.00 |
March | 0.324534E+09 | 86172416.63 | 0.212556E+09 | 28436933.63 | 0.184119E+09 | 0.00 | 0.00 |
April | 0.261344E+09 | 46334800.64 | 0.153447E+09 | 66069.94 | 0.153381E+09 | 0.00 | 0.00 |
May | 0.280063E+09 | 48040821.52 | 0.158673E+09 | 0.00 | 0.158673E+09 | 0.00 | 0.00 |
June | 0.266520E+09 | 50969280.33 | 0.153002E+09 | 0.00 | 0.153002E+09 | 0.00 | 0.00 |
July | 0.270667E+09 | 65119375.14 | 0.162869E+09 | 0.00 | 0.162869E+09 | 0.00 | 0.00 |
August | 0.257998E+09 | 56699197.91 | 0.158550E+09 | 241050.46 | 0.158309E+09 | 0.00 | 0.00 |
September | 0.277139E+09 | 59208705.03 | 0.169828E+09 | 5507024.91 | 0.164320E+09 | 0.00 | 0.00 |
October | 0.351778E+09 | 71487426.71 | 0.229600E+09 | 36570073.28 | 0.193030E+09 | 0.00 | 0.00 |
November | 0.458032E+09 | 88016582.02 | 0.288938E+09 | 88120879.62 | 0.200817E+09 | 0.00 | 0.00 |
December | 0.591357E+09 | 0.128921E+09 | 0.366784E+09 | 0.156029E+09 | 0.210756E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.436122E+10 | 0.922603E+09 | 0.270263E+10 | 0.559748E+09 | 0.214288E+10 | 0.00 | 0.00 |
Minimum of Months | 0.257998E+09 | 46334800.64 | 0.153002E+09 | 0.00 | 0.153002E+09 | 0.00 | 0.00 |
Maximum of Months | 0.591357E+09 | 0.128921E+09 | 0.366954E+09 | 0.156029E+09 | 0.213891E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 26.42 | 22.38 | 20.70 | 2.25 | 18.65 | 103.85 | 146.57 | 0.01 |
February | 27.50 | 22.90 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
April | 29.15 | 25.36 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
May | 29.01 | 26.53 | 25.72 | 3.19 | 22.99 | 127.71 | 124.87 | 0.08 |
June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
August | 27.54 | 25.86 | 25.31 | 3.22 | 21.54 | 129.55 | 122.00 | 0.07 |
September | 27.58 | 25.59 | 24.93 | 2.22 | 22.00 | 128.30 | 103.37 | 0.04 |
October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
November | 26.68 | 24.13 | 23.20 | 1.94 | 20.28 | 113.70 | 103.30 | 0.02 |
December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
Annual Sum or Average | 27.59 | 24.59 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 22.99 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 34.10 | 04-JAN-12:00 | 23.66 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
February | 35.00 | 21-FEB-13:00 | 22.00 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
March | 36.40 | 21-MAR-12:00 | 22.99 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
April | 35.50 | 01-APR-13:00 | 26.95 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
May | 37.60 | 06-MAY-12:00 | 26.41 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
June | 36.00 | 12-JUN-14:00 | 27.58 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
July | 33.20 | 15-JUL-15:00 | 25.62 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
August | 34.00 | 10-AUG-13:00 | 27.85 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
September | 34.00 | 06-SEP-13:00 | 26.50 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
October | 33.00 | 04-OCT-13:00 | 26.22 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
November | 34.30 | 18-NOV-12:00 | 25.33 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
December | 33.00 | 07-DEC-13:00 | 23.21 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 33.00 | 22.00 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
Maximum of Months | 37.60 | 27.85 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
March | 22.00 | 03-MAR-05:00 | 19.93 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 25.52 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
February | 26.16 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
March | 26.27 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
April | 27.92 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.69 | 110.67 | 57.00 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 30.10 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.42 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
September | 30.05 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
November | 27.55 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 25.52 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
Maximum of Months | 30.10 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
April | 27.00 | 10-APR-17:00 | 30.50 | 27.86 | 4.50 | 25.00 | 20.00 | 20.50 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 29.20 | 15-JUN-09:00 | 33.20 | 30.10 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
September | 29.40 | 30-SEP-10:00 | 32.80 | 30.05 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 26.50 | 16-OCT-08:00 | 29.00 | 27.03 | 2.50 | 21.78 | 300.00 | 326.00 |
November | 26.40 | 10-NOV-12:00 | 31.00 | 27.55 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
Maximum of Months | 29.40 | 33.20 | 30.10 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.177307E+10 | -.138733E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385741676.7 | 58.99 | 0.00 | 0.00 |
February | 0.160359E+10 | -.125525E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -348339307.8 | 58.99 | 0.00 | 0.00 |
March | 0.178743E+10 | -.140189E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385536992.8 | 58.99 | 0.00 | 0.00 |
April | 0.167709E+10 | -.130411E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -372983859.3 | 58.99 | 0.00 | 0.00 |
May | 0.170567E+10 | -.132034E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385325049.3 | 58.99 | 0.00 | 0.00 |
June | 0.164794E+10 | -.127514E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -372794445.7 | 58.99 | 0.00 | 0.00 |
July | 0.165792E+10 | -.127253E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385390606.8 | 58.99 | 0.00 | 0.00 |
August | 0.170835E+10 | -.132282E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385522961.2 | 58.99 | 0.00 | 0.00 |
September | 0.165310E+10 | -.128001E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -373093039.7 | 58.99 | 0.00 | 0.00 |
October | 0.171793E+10 | -.133233E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385604586.8 | 58.99 | 0.00 | 0.00 |
November | 0.168443E+10 | -.131118E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -373249744.3 | 58.99 | 0.00 | 0.00 |
December | 0.176832E+10 | -.138261E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385717837.4 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.203849E+11 | -.158456E+11 | 8760.00 | -.453930E+10 | 58.99 | |||||
Minimum of Months | 0.160359E+10 | -.140189E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -385741676.7 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.178743E+10 | -.125525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -348339307.8 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.70 | 0.50 | 01-JAN-11:30 | 446.79 | 8.07 | 0.00 | 77.83 | 375.87 | 6.57 | 0.00 | 55.17 |
February | 321.17 | 0.67 | 0.50 | 01-FEB-09:39 | 2551.38 | 8.65 | 0.00 | 125.83 | 2209.83 | 7.10 | 0.00 | 115.83 |
March | 361.17 | 0.69 | 0.50 | 01-MAR-09:20 | 375.33 | 9.55 | 0.00 | 41.50 | 310.23 | 7.87 | 0.00 | 30.67 |
April | 358.33 | 0.69 | 0.50 | 01-APR-10:50 | 352.10 | 11.09 | 0.00 | 31.00 | 291.73 | 9.32 | 0.00 | 13.33 |
May | 376.33 | 0.69 | 0.50 | 01-MAY-11:50 | 367.56 | 12.11 | 1.83 | 47.00 | 295.13 | 10.30 | 0.00 | 16.17 |
June | 370.50 | 0.67 | 0.50 | 01-JUN-09:50 | 639.26 | 15.59 | 53.17 | 103.83 | 299.46 | 10.90 | 0.00 | 15.83 |
July | 383.17 | 0.69 | 0.50 | 01-JUL-09:30 | 357.12 | 12.09 | 0.00 | 60.17 | 298.74 | 10.42 | 0.00 | 29.67 |
August | 369.33 | 0.68 | 0.50 | 01-AUG-10:20 | 369.79 | 11.77 | 0.00 | 64.33 | 308.62 | 10.07 | 0.00 | 18.33 |
September | 357.83 | 0.68 | 0.50 | 01-SEP-08:00 | 381.31 | 10.35 | 0.00 | 97.67 | 309.36 | 8.78 | 0.00 | 50.50 |
October | 356.83 | 0.67 | 0.50 | 01-OCT-09:30 | 657.12 | 9.61 | 0.00 | 164.83 | 411.82 | 8.01 | 0.00 | 73.83 |
November | 337.67 | 0.69 | 0.50 | 01-NOV-09:20 | 896.84 | 8.77 | 0.00 | 120.00 | 911.39 | 7.18 | 0.00 | 64.50 |
December | 349.33 | 0.70 | 0.50 | 01-DEC-09:20 | 339.03 | 7.94 | 0.00 | 51.00 | 285.42 | 6.44 | 0.00 | 35.83 |
Annual Sum or Average | 4292.33 | 0.68 | 624.04 | 10.53 | 55.00 | 985.00 | 506.41 | 8.64 | 0.00 | 519.67 | ||
Minimum of Months | 321.17 | 0.67 | 0.50 | 339.03 | 7.94 | 0.00 | 31.00 | 285.42 | 6.44 | 0.00 | 13.33 | |
Maximum of Months | 383.17 | 0.70 | 0.50 | 2551.38 | 15.59 | 53.17 | 164.83 | 2209.83 | 10.90 | 0.00 | 115.83 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.356424E+11 | 0.256126E+11 | 48329.57 | 09-JAN-21:08 | 33535.41 | 0.00 |
February | 0.00 | 0.00 | 0.361659E+11 | 0.263726E+11 | 48038.58 | 15-FEB-21:06 | 33961.65 | 0.00 |
March | 0.00 | 0.00 | 0.449090E+11 | 0.323241E+11 | 48242.96 | 25-MAR-03:23 | 34080.31 | 0.00 |
April | 0.00 | 0.00 | 0.496718E+11 | 0.343537E+11 | 48622.88 | 20-APR-20:10 | 31388.32 | 0.00 |
May | 0.00 | 0.00 | 0.566263E+11 | 0.377083E+11 | 48998.67 | 19-MAY-02:63 | 31630.54 | 0.00 |
June | 0.00 | 0.00 | 0.599376E+11 | 0.406514E+11 | 48986.78 | 10-JUN-02:43 | 32520.39 | 0.00 |
July | 0.00 | 0.00 | 0.483678E+11 | 0.340835E+11 | 48528.20 | 07-JUL-20:43 | 33656.55 | 0.00 |
August | 0.00 | 0.00 | 0.494424E+11 | 0.318105E+11 | 48911.84 | 06-AUG-18:43 | 32234.55 | 0.00 |
September | 0.00 | 0.00 | 0.453599E+11 | 0.296981E+11 | 48782.59 | 18-SEP-20:43 | 32634.94 | 0.00 |
October | 0.00 | 0.00 | 0.408231E+11 | 0.262478E+11 | 48901.87 | 25-OCT-20:43 | 32026.43 | 0.00 |
November | 0.00 | 0.00 | 0.378517E+11 | 0.253477E+11 | 48868.67 | 11-NOV-19:10 | 32378.02 | 0.00 |
December | 0.00 | 0.00 | 0.351655E+11 | 0.244564E+11 | 48914.05 | 09-DEC-22:10 | 32659.01 | 0.00 |
Annual Sum or Average | 0.539963E+12 | 0.368667E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.351655E+11 | 0.244564E+11 | 48038.58 | 31388.32 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.599376E+11 | 0.406514E+11 | 48998.67 | 34080.31 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.133150E+12 | 0.821299E+11 | 205422.50 | 02-JAN-07:02 | 99449.45 | 0.00 |
February | 0.00 | 0.00 | 0.133258E+12 | 0.830105E+11 | 205026.24 | 16-FEB-07:02 | 102398.26 | 0.00 |
March | 0.00 | 0.00 | 0.163355E+12 | 0.101371E+12 | 204812.44 | 28-MAR-06:02 | 104558.63 | 0.00 |
April | 0.00 | 0.00 | 0.179752E+12 | 0.102815E+12 | 206480.34 | 15-APR-06:02 | 99129.89 | 0.00 |
May | 0.00 | 0.00 | 0.196888E+12 | 0.103853E+12 | 210074.01 | 19-MAY-06:02 | 89881.87 | 0.00 |
June | 0.00 | 0.00 | 0.198696E+12 | 0.104559E+12 | 209729.35 | 29-JUN-06:02 | 91118.23 | 0.00 |
July | 0.00 | 0.00 | 0.157550E+12 | 0.875597E+11 | 207132.06 | 01-JUL-06:02 | 96699.61 | 0.00 |
August | 0.00 | 0.00 | 0.182722E+12 | 0.918311E+11 | 209186.02 | 05-AUG-06:02 | 90579.16 | 0.00 |
September | 0.00 | 0.00 | 0.172069E+12 | 0.889747E+11 | 209432.49 | 17-SEP-08:62 | 92337.78 | 0.00 |
October | 0.00 | 0.00 | 0.160225E+12 | 0.818100E+11 | 208632.04 | 12-OCT-06:02 | 91646.12 | 0.00 |
November | 0.00 | 0.00 | 0.145637E+12 | 0.791841E+11 | 207671.75 | 12-NOV-09:02 | 98149.79 | 0.00 |
December | 0.00 | 0.00 | 0.135402E+12 | 0.794376E+11 | 206388.06 | 10-DEC-09:02 | 101924.61 | 0.00 |
Annual Sum or Average | 0.195870E+13 | 0.108654E+13 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.133150E+12 | 0.791841E+11 | 204812.44 | 89881.87 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.198696E+12 | 0.104559E+12 | 210074.01 | 104558.63 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.282939E+11 | 0.206091E+11 | 26747.98 | 09-JAN-21:08 | 18234.84 | 0.00 |
February | 0.00 | 0.00 | 0.266905E+11 | 0.194227E+11 | 26613.54 | 15-FEB-21:42 | 18903.67 | 0.00 |
March | 0.00 | 0.00 | 0.296660E+11 | 0.208980E+11 | 26821.89 | 25-MAR-03:23 | 17964.16 | 0.00 |
April | 0.00 | 0.00 | 0.297548E+11 | 0.194431E+11 | 27188.52 | 20-APR-20:10 | 16684.47 | 0.00 |
May | 0.00 | 0.00 | 0.323474E+11 | 0.198374E+11 | 27470.81 | 28-MAY-18:10 | 15810.15 | 0.00 |
June | 0.00 | 0.00 | 0.321127E+11 | 0.196927E+11 | 27405.30 | 03-JUN-21:08 | 16225.26 | 0.00 |
July | 0.00 | 0.00 | 0.266807E+11 | 0.174030E+11 | 27032.14 | 07-JUL-20:08 | 17294.67 | 0.00 |
August | 0.00 | 0.00 | 0.293826E+11 | 0.175366E+11 | 27320.38 | 05-AUG-21:10 | 16563.11 | 0.00 |
September | 0.00 | 0.00 | 0.288162E+11 | 0.178622E+11 | 27204.48 | 18-SEP-20:10 | 17003.62 | 0.00 |
October | 0.00 | 0.00 | 0.284122E+11 | 0.177507E+11 | 27121.44 | 25-OCT-20:10 | 17227.30 | 0.00 |
November | 0.00 | 0.00 | 0.282493E+11 | 0.188130E+11 | 26968.99 | 11-NOV-19:08 | 17467.73 | 0.00 |
December | 0.00 | 0.00 | 0.284646E+11 | 0.201199E+11 | 27083.92 | 09-DEC-22:08 | 17231.90 | 0.00 |
Annual Sum or Average | 0.348871E+12 | 0.229388E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.266807E+11 | 0.174030E+11 | 26613.54 | 15810.15 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.323474E+11 | 0.208980E+11 | 27470.81 | 18903.67 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.247883E+11 | 0.173120E+11 | 23750.66 | 09-JAN-21:08 | 15128.84 | 0.00 |
February | 0.00 | 0.00 | 0.235519E+11 | 0.164486E+11 | 23578.90 | 15-FEB-21:42 | 15818.37 | 0.00 |
March | 0.00 | 0.00 | 0.259160E+11 | 0.174505E+11 | 23726.82 | 25-MAR-03:23 | 15097.83 | 0.00 |
April | 0.00 | 0.00 | 0.261837E+11 | 0.162280E+11 | 24218.35 | 20-APR-20:10 | 13708.69 | 0.00 |
May | 0.00 | 0.00 | 0.287018E+11 | 0.165938E+11 | 24394.42 | 28-MAY-18:10 | 13231.89 | 0.00 |
June | 0.00 | 0.00 | 0.286268E+11 | 0.165563E+11 | 24413.44 | 28-JUN-20:10 | 13253.13 | 0.00 |
July | 0.00 | 0.00 | 0.230824E+11 | 0.142136E+11 | 24057.41 | 07-JUL-20:08 | 14106.35 | 0.00 |
August | 0.00 | 0.00 | 0.255638E+11 | 0.142676E+11 | 24254.06 | 05-AUG-21:10 | 13657.31 | 0.00 |
September | 0.00 | 0.00 | 0.253021E+11 | 0.147516E+11 | 24227.36 | 18-SEP-20:10 | 13781.64 | 0.00 |
October | 0.00 | 0.00 | 0.246024E+11 | 0.144388E+11 | 24131.46 | 25-OCT-20:10 | 14079.20 | 0.00 |
November | 0.00 | 0.00 | 0.247974E+11 | 0.156535E+11 | 23939.79 | 30-NOV-21:08 | 14497.53 | 0.00 |
December | 0.00 | 0.00 | 0.249546E+11 | 0.168439E+11 | 23998.13 | 09-DEC-22:08 | 14379.65 | 0.00 |
Annual Sum or Average | 0.306071E+12 | 0.190758E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.230824E+11 | 0.142136E+11 | 23578.90 | 13231.89 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.287018E+11 | 0.174505E+11 | 24413.44 | 15818.37 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:03 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:03 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.186590E+10 | 0.49 | 2360.96 | 02-JAN-21:08 | 0.87 |
February | 0.177842E+10 | 0.50 | 2360.96 | 01-FEB-21:06 | 0.87 |
March | 0.213062E+10 | 0.51 | 2360.96 | 01-MAR-21:08 | 0.87 |
April | 0.227660E+10 | 0.53 | 2360.96 | 01-APR-04:03 | 0.87 |
May | 0.258804E+10 | 0.55 | 2360.96 | 01-MAY-20:06 | 0.87 |
June | 0.274645E+10 | 0.57 | 2360.96 | 01-JUN-01:23 | 0.87 |
July | 0.224624E+10 | 0.52 | 2360.96 | 01-JUL-21:08 | 0.87 |
August | 0.227882E+10 | 0.52 | 2360.96 | 01-AUG-00:03 | 0.87 |
September | 0.209791E+10 | 0.51 | 2360.96 | 01-SEP-00:03 | 0.87 |
October | 0.196042E+10 | 0.49 | 2360.96 | 01-OCT-03:43 | 0.87 |
November | 0.184873E+10 | 0.49 | 2360.96 | 01-NOV-20:08 | 0.87 |
December | 0.184083E+10 | 0.48 | 2360.96 | 01-DEC-21:08 | 0.87 |
Annual Sum or Average | 0.256590E+11 | 0.51 | |||
Minimum of Months | 0.177842E+10 | 0.48 | 2360.96 | 0.87 | |
Maximum of Months | 0.274645E+10 | 0.57 | 2360.96 | 0.87 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.845743E+10 | 0.51 | 12382.91 | 01-JAN-09:02 | 1.36 |
February | 0.816027E+10 | 0.53 | 12382.91 | 01-FEB-07:02 | 1.36 |
March | 0.974846E+10 | 0.56 | 12382.91 | 01-MAR-07:02 | 1.36 |
April | 0.104764E+11 | 0.59 | 12382.91 | 01-APR-05:03 | 1.36 |
May | 0.113746E+11 | 0.61 | 12382.91 | 01-MAY-05:02 | 1.36 |
June | 0.115507E+11 | 0.63 | 12382.91 | 01-JUN-05:03 | 1.36 |
July | 0.921087E+10 | 0.54 | 12382.91 | 01-JUL-06:02 | 1.35 |
August | 0.106139E+11 | 0.59 | 12382.91 | 01-AUG-06:02 | 1.35 |
September | 0.997992E+10 | 0.57 | 12382.91 | 01-SEP-06:02 | 1.35 |
October | 0.934364E+10 | 0.54 | 12382.91 | 01-OCT-08:62 | 1.35 |
November | 0.865206E+10 | 0.53 | 12382.91 | 01-NOV-06:02 | 1.35 |
December | 0.845519E+10 | 0.51 | 12382.91 | 01-DEC-07:03 | 1.36 |
Annual Sum or Average | 0.116023E+12 | 0.56 | |||
Minimum of Months | 0.816027E+10 | 0.51 | 12382.91 | 1.35 | |
Maximum of Months | 0.115507E+11 | 0.63 | 12382.91 | 1.36 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.130264E+10 | 0.56 | 1261.04 | 02-JAN-21:08 | 0.90 |
February | 0.122349E+10 | 0.57 | 1261.04 | 01-FEB-05:43 | 0.90 |
March | 0.133542E+10 | 0.57 | 1261.04 | 01-MAR-21:08 | 0.90 |
April | 0.130892E+10 | 0.57 | 1261.04 | 01-APR-04:03 | 0.90 |
May | 0.140639E+10 | 0.58 | 1261.04 | 01-MAY-20:06 | 0.90 |
June | 0.139833E+10 | 0.58 | 1261.04 | 01-JUN-01:23 | 0.90 |
July | 0.118045E+10 | 0.54 | 1261.04 | 01-JUL-21:08 | 0.90 |
August | 0.128312E+10 | 0.56 | 1261.04 | 01-AUG-00:03 | 0.90 |
September | 0.126431E+10 | 0.56 | 1261.04 | 01-SEP-00:03 | 0.90 |
October | 0.125614E+10 | 0.55 | 1261.04 | 01-OCT-03:43 | 0.90 |
November | 0.126401E+10 | 0.56 | 1261.04 | 01-NOV-20:08 | 0.90 |
December | 0.129613E+10 | 0.56 | 1261.04 | 01-DEC-21:06 | 0.90 |
Annual Sum or Average | 0.155193E+11 | 0.56 | |||
Minimum of Months | 0.118045E+10 | 0.54 | 1261.04 | 0.90 | |
Maximum of Months | 0.140639E+10 | 0.58 | 1261.04 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.107936E+10 | 0.55 | 1056.83 | 02-JAN-21:08 | 0.90 |
February | 0.101905E+10 | 0.56 | 1056.83 | 01-FEB-05:43 | 0.90 |
March | 0.110270E+10 | 0.56 | 1056.83 | 01-MAR-21:08 | 0.90 |
April | 0.108171E+10 | 0.56 | 1056.83 | 01-APR-04:03 | 0.90 |
May | 0.117133E+10 | 0.57 | 1056.83 | 01-MAY-20:06 | 0.89 |
June | 0.116893E+10 | 0.57 | 1056.83 | 01-JUN-01:23 | 0.90 |
July | 0.967048E+09 | 0.53 | 1056.83 | 01-JUL-21:08 | 0.90 |
August | 0.105399E+10 | 0.54 | 1056.83 | 01-AUG-00:03 | 0.90 |
September | 0.104620E+10 | 0.55 | 1056.83 | 01-SEP-00:03 | 0.90 |
October | 0.102985E+10 | 0.54 | 1056.83 | 01-OCT-03:43 | 0.90 |
November | 0.104685E+10 | 0.55 | 1056.83 | 01-NOV-20:08 | 0.90 |
December | 0.107442E+10 | 0.55 | 1056.83 | 01-DEC-21:06 | 0.90 |
Annual Sum or Average | 0.128414E+11 | 0.55 | |||
Minimum of Months | 0.967048E+09 | 0.53 | 1056.83 | 0.89 | |
Maximum of Months | 0.117133E+10 | 0.57 | 1056.83 | 0.90 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.39 | 0.00 |
February | 3.08 | 0.00 |
March | 4.03 | 0.00 |
April | 3.86 | 0.00 |
May | 3.69 | 1.55 |
June | 3.92 | 0.92 |
July | 3.28 | 0.00 |
August | 3.19 | 0.67 |
September | 3.36 | 0.00 |
October | 2.50 | 0.00 |
November | 2.14 | 0.00 |
December | 1.69 | 0.00 |
Annual Sum or Average | 37.14 | 0.31 |
Minimum of Months | 1.69 | 0.00 |
Maximum of Months | 4.03 | 1.55 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.71 | 0.00 |
February | 2.21 | 0.00 |
March | 0.12 | 0.00 |
April | 0.20 | 0.00 |
May | 1.08 | 0.00 |
June | 0.68 | 0.00 |
July | 0.92 | 0.00 |
August | 0.33 | 0.00 |
September | 0.46 | 0.00 |
October | 0.62 | 0.00 |
November | 1.37 | 0.00 |
December | 3.30 | 0.00 |
Annual Sum or Average | 15.01 | 0.00 |
Minimum of Months | 0.12 | 0.00 |
Maximum of Months | 3.71 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.109504E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.110112E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.135924E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.148509E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.167823E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.176952E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.142246E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.144312E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.133206E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.120360E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.112684E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.107208E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.160884E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.107208E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.176952E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.436404E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.435343E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.532512E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.575853E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.621959E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.627796E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.496135E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.566826E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.535550E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.496617E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.457999E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.437057E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.622005E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.435343E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.627796E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.815775E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.776890E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.865502E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.861572E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.926102E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.917573E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.760586E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.827193E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.814800E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.799811E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.800296E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.811743E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.997784E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.760586E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.926102E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.706440E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.676974E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.746801E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.745946E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.807146E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.803049E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.650034E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.708401E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.704389E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.682678E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.692908E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.703135E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.862790E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.650034E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.807146E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.186590E+10 | 0.356424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.177842E+10 | 0.361659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.213062E+10 | 0.449090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.227660E+10 | 0.496718E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.258804E+10 | 0.566263E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.274645E+10 | 0.599376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.224624E+10 | 0.483678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.227882E+10 | 0.494424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.209791E+10 | 0.453599E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.196042E+10 | 0.408231E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.184873E+10 | 0.378517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.184083E+10 | 0.351655E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.256590E+11 | 0.539963E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.177842E+10 | 0.351655E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.274645E+10 | 0.599376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.845743E+10 | 0.133150E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.816027E+10 | 0.133258E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.974846E+10 | 0.163355E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104764E+11 | 0.179752E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.113746E+11 | 0.196888E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.115507E+11 | 0.198696E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.921087E+10 | 0.157550E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.106139E+11 | 0.182722E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.997992E+10 | 0.172069E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.934364E+10 | 0.160225E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.865206E+10 | 0.145637E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.845519E+10 | 0.135402E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116023E+12 | 0.195870E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.816027E+10 | 0.133150E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.115507E+11 | 0.198696E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.130264E+10 | 0.282939E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122349E+10 | 0.266905E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133542E+10 | 0.296660E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.130892E+10 | 0.297548E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.140639E+10 | 0.323474E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.139833E+10 | 0.321127E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.118045E+10 | 0.266807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.128312E+10 | 0.293826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126431E+10 | 0.288162E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125614E+10 | 0.284122E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126401E+10 | 0.282493E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129613E+10 | 0.284646E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.155193E+11 | 0.348871E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.118045E+10 | 0.266807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.140639E+10 | 0.323474E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.107936E+10 | 0.247883E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.101905E+10 | 0.235519E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.110270E+10 | 0.259160E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.108171E+10 | 0.261837E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.117133E+10 | 0.287018E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.116893E+10 | 0.286268E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.967048E+09 | 0.230824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.105399E+10 | 0.255638E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.104620E+10 | 0.253021E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.102985E+10 | 0.246024E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.104685E+10 | 0.247974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.107442E+10 | 0.249546E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.128414E+11 | 0.306071E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.967048E+09 | 0.230824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.117133E+10 | 0.287018E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.186590E+10 | 0.00 | 0.00 | 0.00 | 0.908454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.177842E+10 | 0.00 | 0.00 | 0.00 | 0.923276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.213062E+10 | 0.00 | 0.00 | 0.00 | 0.114618E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.227660E+10 | 0.00 | 0.00 | 0.00 | 0.125743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.258804E+10 | 0.00 | 0.00 | 0.00 | 0.141942E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.274645E+10 | 0.00 | 0.00 | 0.00 | 0.149488E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.224624E+10 | 0.00 | 0.00 | 0.00 | 0.119783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.227882E+10 | 0.00 | 0.00 | 0.00 | 0.121524E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.209791E+10 | 0.00 | 0.00 | 0.00 | 0.112227E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.196042E+10 | 0.00 | 0.00 | 0.00 | 0.100755E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.184873E+10 | 0.00 | 0.00 | 0.00 | 0.941969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.184083E+10 | 0.00 | 0.00 | 0.00 | 0.887998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.256590E+11 | 0.00 | 0.00 | 0.00 | 0.135225E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.177842E+10 | 0.00 | 0.00 | 0.00 | 0.887998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.274645E+10 | 0.00 | 0.00 | 0.00 | 0.149488E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.845743E+10 | 0.00 | 0.00 | 0.00 | 0.351830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.816027E+10 | 0.00 | 0.00 | 0.00 | 0.353741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.974846E+10 | 0.00 | 0.00 | 0.00 | 0.435028E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104764E+11 | 0.00 | 0.00 | 0.00 | 0.471089E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.113746E+11 | 0.00 | 0.00 | 0.00 | 0.508212E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.115507E+11 | 0.00 | 0.00 | 0.00 | 0.512288E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.921087E+10 | 0.00 | 0.00 | 0.00 | 0.404026E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.106139E+11 | 0.00 | 0.00 | 0.00 | 0.460688E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.997992E+10 | 0.00 | 0.00 | 0.00 | 0.435751E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.934364E+10 | 0.00 | 0.00 | 0.00 | 0.403180E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.865206E+10 | 0.00 | 0.00 | 0.00 | 0.371478E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.845519E+10 | 0.00 | 0.00 | 0.00 | 0.352505E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116023E+12 | 0.00 | 0.00 | 0.00 | 0.505982E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.816027E+10 | 0.00 | 0.00 | 0.00 | 0.351830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.115507E+11 | 0.00 | 0.00 | 0.00 | 0.512288E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.130264E+10 | 0.00 | 0.00 | 0.00 | 0.685511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122349E+10 | 0.00 | 0.00 | 0.00 | 0.654542E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133542E+10 | 0.00 | 0.00 | 0.00 | 0.731960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.130892E+10 | 0.00 | 0.00 | 0.00 | 0.730680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.140639E+10 | 0.00 | 0.00 | 0.00 | 0.785463E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.139833E+10 | 0.00 | 0.00 | 0.00 | 0.777740E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.118045E+10 | 0.00 | 0.00 | 0.00 | 0.642541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.128312E+10 | 0.00 | 0.00 | 0.00 | 0.698881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126431E+10 | 0.00 | 0.00 | 0.00 | 0.688369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125614E+10 | 0.00 | 0.00 | 0.00 | 0.674196E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126401E+10 | 0.00 | 0.00 | 0.00 | 0.673895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129613E+10 | 0.00 | 0.00 | 0.00 | 0.682131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.155193E+11 | 0.00 | 0.00 | 0.00 | 0.842591E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.118045E+10 | 0.00 | 0.00 | 0.00 | 0.642541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.140639E+10 | 0.00 | 0.00 | 0.00 | 0.785463E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.107936E+10 | 0.00 | 0.00 | 0.00 | 0.598504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.101905E+10 | 0.00 | 0.00 | 0.00 | 0.575069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.110270E+10 | 0.00 | 0.00 | 0.00 | 0.636530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.108171E+10 | 0.00 | 0.00 | 0.00 | 0.637774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.117133E+10 | 0.00 | 0.00 | 0.00 | 0.690013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.116893E+10 | 0.00 | 0.00 | 0.00 | 0.686156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.967048E+09 | 0.00 | 0.00 | 0.00 | 0.553329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.105399E+10 | 0.00 | 0.00 | 0.00 | 0.603001E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.104620E+10 | 0.00 | 0.00 | 0.00 | 0.599769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.102985E+10 | 0.00 | 0.00 | 0.00 | 0.579693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.104685E+10 | 0.00 | 0.00 | 0.00 | 0.588223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.107442E+10 | 0.00 | 0.00 | 0.00 | 0.595693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.128414E+11 | 0.00 | 0.00 | 0.00 | 0.734376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.967048E+09 | 0.00 | 0.00 | 0.00 | 0.553329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.117133E+10 | 0.00 | 0.00 | 0.00 | 0.690013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.936227E+10 | 0.00 | 0.00 | 3810956.04 | 0.00 | 0.00 | 0.00 | 0.25 |
February | 0.00 | 0.968677E+10 | 0.00 | 0.00 | 5640351.63 | 0.00 | 0.00 | 0.00 | 0.25 |
March | 0.00 | 0.121424E+11 | 0.00 | 0.00 | 2432145.82 | 0.00 | 0.00 | 0.00 | 0.26 |
April | 0.00 | 0.153386E+11 | 0.00 | 0.00 | 7461728.81 | 0.00 | 0.00 | 0.00 | 0.27 |
May | 0.00 | 0.186030E+11 | 0.00 | 0.00 | 5378626.66 | 0.00 | 0.00 | 0.00 | 0.27 |
June | 0.00 | 0.189864E+11 | 0.00 | 0.00 | 3828262.40 | 0.00 | 0.00 | 0.00 | 0.28 |
July | 0.00 | 0.137925E+11 | 0.00 | 0.00 | 6328904.00 | 0.00 | 0.00 | 0.00 | 0.27 |
August | 0.00 | 0.165712E+11 | 0.00 | 0.00 | 8058648.10 | 0.00 | 0.00 | 0.00 | 0.27 |
September | 0.00 | 0.152645E+11 | 0.00 | 0.00 | 3324936.64 | 0.00 | 0.00 | 0.00 | 0.26 |
October | 0.00 | 0.138667E+11 | 0.00 | 0.00 | 17509648.55 | 0.00 | 0.00 | 0.00 | 0.25 |
November | 0.00 | 0.118953E+11 | 0.00 | 0.00 | 10046975.29 | 0.00 | 0.00 | 0.00 | 0.25 |
December | 0.00 | 0.998726E+10 | 0.00 | 0.00 | 7618089.18 | 0.00 | 0.00 | 0.00 | 0.25 |
Annual Sum or Average | 0.00 | 0.165497E+12 | 0.00 | 0.00 | 81439273.11 | 0.00 | 0.00 | 0.00 | 0.26 |
Minimum of Months | 0.00 | 0.936227E+10 | 0.00 | 0.00 | 2432145.82 | 0.00 | 0.00 | 0.00 | 0.25 |
Maximum of Months | 0.00 | 0.189864E+11 | 0.00 | 0.00 | 17509648.55 | 0.00 | 0.00 | 0.00 | 0.28 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 84799742.02 | 0.577115E+11 | 0.00 | 1380144.49 | 0.110452E+10 | 0.00 | 34381771.52 | 0.00 | 0.43 |
February | 4331472.34 | 0.595302E+11 | 0.00 | 1333651.27 | 0.115220E+10 | 0.00 | 10329923.92 | 0.00 | 0.43 |
March | 0.00 | 0.748070E+11 | 0.00 | 0.00 | 0.156670E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
April | 0.00 | 0.920571E+11 | 0.00 | 0.00 | 0.153632E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
May | 0.00 | 0.108339E+12 | 0.00 | 0.00 | 0.182209E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
June | 0.00 | 0.109270E+12 | 0.00 | 0.00 | 0.164445E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
July | 0.00 | 0.777201E+11 | 0.00 | 0.00 | 0.179141E+10 | 0.00 | 0.00 | 0.00 | 0.43 |
August | 0.00 | 0.997337E+11 | 0.00 | 0.00 | 0.211376E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.920140E+11 | 0.00 | 0.00 | 0.201093E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 0.00 | 0.847508E+11 | 0.00 | 0.00 | 0.223717E+10 | 0.00 | 0.00 | 0.00 | 0.43 |
November | 7143572.46 | 0.726399E+11 | 0.00 | 235567.48 | 0.149868E+10 | 0.00 | 743251.87 | 0.00 | 0.43 |
December | 15538606.79 | 0.615836E+11 | 0.00 | 69746.20 | 0.138234E+10 | 0.00 | 2568713.36 | 0.00 | 0.43 |
Annual Sum or Average | 0.111813E+09 | 0.990157E+12 | 0.00 | 3019109.44 | 0.198606E+11 | 0.00 | 48023660.66 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.577115E+11 | 0.00 | 0.00 | 0.110452E+10 | 0.00 | 0.00 | 0.00 | 0.43 |
Maximum of Months | 84799742.02 | 0.109270E+12 | 0.00 | 1380144.49 | 0.223717E+10 | 0.00 | 34381771.52 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.816681E+10 | 0.00 | 0.00 | 2458586.81 | 0.00 | 0.00 | 0.00 | 0.50 |
February | 0.00 | 0.811210E+10 | 0.00 | 0.00 | 2594133.72 | 0.00 | 0.00 | 0.00 | 0.51 |
March | 0.00 | 0.973336E+10 | 0.00 | 0.00 | 1892222.38 | 0.00 | 0.00 | 0.00 | 0.52 |
April | 0.00 | 0.116083E+11 | 0.00 | 0.00 | 5642788.61 | 0.00 | 0.00 | 0.00 | 0.52 |
May | 0.00 | 0.137284E+11 | 0.00 | 0.00 | 2695347.06 | 0.00 | 0.00 | 0.00 | 0.52 |
June | 0.00 | 0.136148E+11 | 0.00 | 0.00 | 3915819.52 | 0.00 | 0.00 | 0.00 | 0.52 |
July | 0.00 | 0.100121E+11 | 0.00 | 0.00 | 2143795.99 | 0.00 | 0.00 | 0.00 | 0.50 |
August | 0.00 | 0.124228E+11 | 0.00 | 0.00 | 6957649.58 | 0.00 | 0.00 | 0.00 | 0.51 |
September | 0.00 | 0.117766E+11 | 0.00 | 0.00 | 2505871.77 | 0.00 | 0.00 | 0.00 | 0.51 |
October | 0.00 | 0.112131E+11 | 0.00 | 0.00 | 6223779.04 | 0.00 | 0.00 | 0.00 | 0.50 |
November | 0.00 | 0.997250E+10 | 0.00 | 0.00 | 2175714.28 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.875408E+10 | 0.00 | 0.00 | 2175052.68 | 0.00 | 0.00 | 0.00 | 0.50 |
Annual Sum or Average | 0.00 | 0.129115E+12 | 0.00 | 0.00 | 41380761.44 | 0.00 | 0.00 | 0.00 | 0.51 |
Minimum of Months | 0.00 | 0.811210E+10 | 0.00 | 0.00 | 1892222.38 | 0.00 | 0.00 | 0.00 | 0.50 |
Maximum of Months | 0.00 | 0.137284E+11 | 0.00 | 0.00 | 6957649.58 | 0.00 | 0.00 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.797092E+10 | 0.00 | 0.00 | 2452450.13 | 0.00 | 0.00 | 0.00 | 0.50 |
February | 0.00 | 0.795888E+10 | 0.00 | 0.00 | 2588764.11 | 0.00 | 0.00 | 0.00 | 0.51 |
March | 0.00 | 0.945532E+10 | 0.00 | 0.00 | 1864139.33 | 0.00 | 0.00 | 0.00 | 0.52 |
April | 0.00 | 0.112770E+11 | 0.00 | 0.00 | 5544530.85 | 0.00 | 0.00 | 0.00 | 0.52 |
May | 0.00 | 0.133634E+11 | 0.00 | 0.00 | 2658750.24 | 0.00 | 0.00 | 0.00 | 0.52 |
June | 0.00 | 0.132971E+11 | 0.00 | 0.00 | 3854284.80 | 0.00 | 0.00 | 0.00 | 0.53 |
July | 0.00 | 0.961520E+10 | 0.00 | 0.00 | 2128315.22 | 0.00 | 0.00 | 0.00 | 0.50 |
August | 0.00 | 0.119069E+11 | 0.00 | 0.00 | 7548275.00 | 0.00 | 0.00 | 0.00 | 0.51 |
September | 0.00 | 0.113919E+11 | 0.00 | 0.00 | 2483536.14 | 0.00 | 0.00 | 0.00 | 0.51 |
October | 0.00 | 0.107362E+11 | 0.00 | 0.00 | 8441888.64 | 0.00 | 0.00 | 0.00 | 0.50 |
November | 0.00 | 0.969324E+10 | 0.00 | 0.00 | 2151533.36 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.853203E+10 | 0.00 | 0.00 | 2150118.05 | 0.00 | 0.00 | 0.00 | 0.50 |
Annual Sum or Average | 0.00 | 0.125198E+12 | 0.00 | 0.00 | 43866585.88 | 0.00 | 0.00 | 0.00 | 0.51 |
Minimum of Months | 0.00 | 0.795888E+10 | 0.00 | 0.00 | 1864139.33 | 0.00 | 0.00 | 0.00 | 0.50 |
Maximum of Months | 0.00 | 0.133634E+11 | 0.00 | 0.00 | 8441888.64 | 0.00 | 0.00 | 0.00 | 0.53 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |