Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
Simulation Timestamp: 2020-06-03 19:11:32
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2017.01 | 879.26 | 879.26 |
Net Site Energy | 2017.01 | 879.26 | 879.26 |
Total Source Energy | 4996.01 | 2177.87 | 2177.87 |
Net Source Energy | 4996.01 | 2177.87 | 2177.87 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 569.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 158.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 492.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 114.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 387.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 98.75 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1348.81 | 668.20 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 569.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 158.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 492.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 114.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 387.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 98.75 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 264.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 238.28 | 291.28 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 587.98 | 291.28 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 264.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 238.28 | 291.28 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 587.98 | 291.28 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1348.811 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1348.811 | 100.00 |
Total On-Site and Utility Electric Sources | 1348.811 | 100.00 |
Total Electricity End Uses | 1348.811 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1840.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2007
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Latitude [deg] | 42.93 |
Longitude [deg] | -78.7 |
Elevation [m] | 215.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 8.56 |
Skylight-Roof Ratio [%] | 0.37 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 9.0309 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 18.2986 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.2986 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.2986 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 13.9931 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.7414 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.7414 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 15-JUL-14:39 | 07-FEB-07:10 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 243182.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 50072.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 18252.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 4589.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 113660.37 | 247771.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 243182.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 50072.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 18252.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 4589.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 617.28 | 0.00 | 0.00 | 0.00 |
Cooling | 503.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1558.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 364.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1227.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 107.05 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4271.68 | 724.33 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 269.09 | 0.00 | 0.00 | 0.00 |
Cooling | 219.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 679.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 158.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 535.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 46.67 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1862.12 | 315.75 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 269.09 | 0.00 | 0.00 | 0.00 |
Cooling | 219.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 679.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 158.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 535.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 46.67 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1862.12 | 315.75 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 1.80 |
CORE_RETAIL DIRECT AIR | 7.92 |
POINT_OF_SALE DIRECT AIR | 1.10 |
FRONT_RETAIL DIRECT AIR | 0.877180 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 2.56 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 2.56 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 58327.71 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 50543.16 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 261764.52 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 32592.86 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 27545.69 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 1.80 | 1.80 | 1.80 | 1.80 | 1.83 | 1.83 | 1.00 | 0.980289 | 1.83 |
PSZ-AC:2 | 7.92 | 7.92 | 7.92 | 7.92 | 8.12 | 8.12 | 1.00 | 0.975059 | 8.12 |
PSZ-AC:3 | 1.10 | 1.10 | 1.10 | 1.10 | 1.11 | 1.11 | 1.00 | 0.996656 | 1.11 |
PSZ-AC:4 | 0.877180 | 0.877180 | 0.877180 | 0.877180 | 0.877180 | 0.877180 | 1.00 | 1.00 | 0.877180 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 1.83 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 8.12 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.11 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.877180 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 1.83 | 1.83 | 1.83 | 1.83 | 35529.44 | 50543.16 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 8.12 | 8.12 | 8.12 | 8.12 | 169703.93 | 261764.52 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.11 | 1.11 | 1.11 | 1.11 | 21157.85 | 32592.86 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.877180 | 0.877180 | 0.877180 | 0.877180 | 17646.13 | 27545.69 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 1.83 | 0.916080 | 1.83 | 33206.27 | 35529.44 | 17764.72 | 35529.44 | 0.744839 | 0.744840 | 0.744840 | 0.744840 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 8.12 | 4.06 | 8.12 | 159602.30 | 169703.93 | 84851.96 | 169703.93 | 0.722329 | 0.722330 | 0.722330 | 0.722330 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.11 | 0.552685 | 1.11 | 19751.84 | 21157.85 | 10578.92 | 21157.85 | 0.748957 | 0.748960 | 0.748960 | 0.748960 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.877180 | 0.438590 | 0.877180 | 16544.44 | 17646.13 | 8823.07 | 17646.13 | 0.733532 | 0.733530 | 0.733530 | 0.733530 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.83 | 2005.31 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 8.12 | 13986.59 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.11 | 1260.24 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.877180 | 1000.08 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.70 | 6.00 | -2.20 | -3.40 | -4.20 | 2.70 | 7.50 | 13.70 | 18.60 | 22.00 | 20.70 | 16.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 | 42.93 | -78.73 | -5.00 | 215.00 | 98769 | 1.1739 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 8.97 | 26.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 65 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 6.69 | 10 | 14 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 9.031 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.101 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 18.299 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.529 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 18.299 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 39.819 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 18.299 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.529 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 13.993 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13.993 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 3430.757 | 9.031 | 55.928 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3430.757 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 29286.673 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 29286.673 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2759.619 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2759.619 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2759.619 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2759.619 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 167.917 | 13.993 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 167.917 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 2.841 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.5534 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3520 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.640 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.8390000 | 2.8390000 | 2.8390000 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 2.8409091 | 2.8409091 | 2.8409091 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 9 | 0.29758781E-14 | -0.29065710E-15 | -0.16717921E-09 | -0.54082436E-16 |
25 | 8 | 0.24322757E-07 | 0.75510264E-13 | 0.40304845E-03 | -0.27655812E-09 |
26 | 7 | -0.12993629E-01 | 0.38338009E-08 | -0.24168191E-01 | 0.14774231E-03 |
27 | 6 | 0.42578349 | 0.13225368E-05 | 0.48945559 | -0.49886206E-02 |
28 | 5 | -5.3899404 | 0.49024379E-04 | -4.5744615 | 0.65656055E-01 |
29 | 4 | 33.884590 | 0.39840510E-03 | 21.960611 | -0.43383013 |
30 | 3 | -113.10176 | 0.86320527E-03 | -56.652426 | 1.5422922 |
31 | 2 | 198.98955 | 0.48301085E-03 | 78.818690 | -2.9302292 |
32 | 1 | -171.85079 | 0.51313109E-04 | -55.530381 | 2.7576150 |
33 | 0 | 57.057407 | 0.29052359E-06 | 15.514123 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 30 | 1 | VerySmooth | 2.672 | 0.394 | 0.315 | 0.401 |
2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 31 | 1 | VerySmooth | 5.779 | 0.490 | 0.326 | 0.491 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.40629E-002 | 0.31435 | 0.46917 | 0.46917 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11822 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.32532 | 0.12431 | 0.12431 | 0.49000 | 0.13099 | 0.16159 | 0.00000 | 0.84000 | 0.84000 | 0.30192 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.727 | 0.1878 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
31 | SKYLIGHTS_R2C4 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
32 | SKYLIGHTS_R2C1 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
33 | SKYLIGHTS_R2C2 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
34 | SKYLIGHTS_R2C3 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C3 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C1 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C2 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
39 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
40 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
42 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
43 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
44 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
45 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
46 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
47 | POINT_OF_SALE_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
48 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
49 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
50 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
52 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
54 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | FRONT_RETAIL_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
58 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
59 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
60 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
62 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
63 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
64 | FRONT_ENTRY_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
65 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.448 | 1.180E-003 | 5.356E-004 | 0.697 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.367 | 2.293E-004 | 1.864E-004 | 0.135 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 2.497E-002 | 2.080E-003 | 6.862E-004 | 1.228 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.937 | 7.811E-002 | 2.576E-002 | 46.096 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 20698.70056 | 24838.44067 | 1.49671 | 1.79605 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.41800 | 1.33455E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 27629.21051 | 33155.05261 | 1.19670 | 1.43604 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -16.30000 | 9.24091E-004 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 91162.85104 | 109395.42125 | 6.60076 | 7.92091 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.41800 | 1.33455E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 66213.36435 | 79456.03722 | 2.83330 | 3.39996 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -16.30000 | 9.24091E-004 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 12537.84871 | 15045.41846 | 0.91806 | 1.10167 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.41800 | 1.33455E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 13456.95386 | 16148.34463 | 0.58491 | 0.70189 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -16.30000 | 9.24091E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 9711.02137 | 11653.22564 | 0.73098 | 0.87718 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 30.14500 | 1.33455E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 13458.87928 | 16150.65513 | 0.58499 | 0.70199 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -16.30000 | 9.24091E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 30.30000 | 1.33455E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 48566.39727 | 58279.67672 | 2.13672 | 2.56407 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | -16.30000 | 9.24091E-004 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 24001.28 | 1.83216 | 1.83216 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 42451.44 | 1.43604 | 1.43604 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 114686.90 | 8.12352 | 8.12352 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 159639.05 | 3.39996 | 3.39996 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 15779.57 | 1.10537 | 1.10537 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 23604.77 | 0.70189 | 0.70189 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 12807.93 | 0.87718 | 0.87718 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 23607.06 | 0.70199 | 0.70199 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.79605 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 7.92091 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.10167 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87718 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 2.56407 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 2.56407 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 58327.70586 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.79605 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.79605 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.79605 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.79605 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.83216 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.83216 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.98029 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 7.92091 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 7.92091 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.92091 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 7.92091 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 8.12352 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 8.12352 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.97506 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.10167 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.10167 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.10167 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.10167 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.10537 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.10537 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 0.99666 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.87718 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.87718 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.87718 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.87718 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.87718 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.87718 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 1.83216 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 8.12352 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.10537 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.87718 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.83216 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.83216 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.83216 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.83216 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.83216 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.83216 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.91608 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.83216 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 33206.27109 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 35529.44000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 17764.72000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 35529.44000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.74484 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.74484 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.74484 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.74484 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 35529.44000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 50543.16293 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.83216 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2005.31274 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 50543.16293 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 8.12352 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 8.12352 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 8.12352 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 8.12352 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 8.12352 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 8.12352 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 4.06176 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 8.12352 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 159602.29609 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 169703.93000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 84851.96500 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 169703.93000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72233 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72233 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72233 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72233 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 169703.93000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 261764.52273 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 8.12352 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 13986.59433 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 261764.52273 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.10537 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.10537 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.10537 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.10537 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.10537 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.10537 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.55269 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.10537 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 19751.83922 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21157.85000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10578.92500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21157.85000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.74896 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.74896 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.74896 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.74896 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21157.85000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 32592.85694 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.10537 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1260.24328 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 32592.85694 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.87718 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.87718 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.87718 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.87718 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.87718 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.87718 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.43859 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.87718 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 16544.43602 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17646.13000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8823.06500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17646.13000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73353 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73353 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73353 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73353 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17646.13000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27545.69276 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.87718 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1000.08160 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27545.69276 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 34090.3 | 10.27 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 163315.3 | 11.71 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 20289.8 | 110.01 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 16956.7 | 157.27 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 25 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1591.92 | 1600.48 | 1593.79 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
32 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
33 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
34 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
40 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
45 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
54 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
56 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
57 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
58 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | |
1 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C4 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
2 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C1 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
3 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C2 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
4 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C3 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
5 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C3 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
6 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C1 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
7 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C4 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
8 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C2 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 9 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 0.1073297845 | 0.3932205287 | Pass | Pass | 3.6375552668E-002 | 0.1433303193 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 5.3998526848E-002 | 0.2497097603 | Pass | Pass | 0.1024459104 | 0.4342073420 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 0.1129209696 | 0.4550190306 | Pass | Pass | 5.0623972409E-002 | 0.1574585215 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 0.1390073016 | 0.4483327094 | Pass | Pass | 0.3911196021 | 2.0437681562 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.2045305280 | 0.5475608123 | Pass | Pass | 0.1044451977 | 0.5164692078 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | -16.30 | 0.00 | -16.30 | Wetbulb [C] | 5.10 | 270.00 |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 30.30 | 9.30 | 21.80 | Wetbulb [C] | 5.70 | 240.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 1600.48 | 1591.92 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.672 | 0.394 | 0.401 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.672 | 0.394 | 0.401 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.672 | 0.394 | 0.401 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 92.49 | 2.959 | 0.403 | 0.409 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 92.49 | 2.959 | 0.403 | 0.409 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 9.0309 | 379.89 | 3430.76 | LightsWired | BLDG_LIGHT_BACK_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 43.96 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 18.2986 | 1600.48 | 29286.67 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 375.23 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 18.2986 | 150.81 | 2759.62 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 35.36 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 18.2986 | 150.81 | 2759.62 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 35.36 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 13.9931 | 12.00 | 167.92 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 2.15 |
Interior Lighting Total | 16.7414 | 2293.99 | 38404.58 | 492.05 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7321.52 | AstronomicalClock | - | 83.67 | 83.67 | 114.99 | |
Exterior Lighting Total | 7321.52 | 114.99 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 35529.44 | 26463.75 | 9065.69 | 0.74 | 3.50 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 169703.93 | 122582.24 | 47121.69 | 0.72 | 3.23 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 21157.85 | 15846.38 | 5311.47 | 0.75 | 3.50 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17646.13 | 12943.97 | 4702.16 | 0.73 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 34090.3 | 10.27 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 163315.3 | 11.71 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 20289.8 | 110.01 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 16956.7 | 157.27 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 58327.71 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 50543.16 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 261764.52 | 0.79 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 32592.86 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27545.69 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.57 | 622.50 | 2.56 | 2806.39 | 1094.51 | 1.00 | 1.24 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 1.83 | 2005.31 | 1094.51 | 1.00 | 1.30 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.59 | 1018.41 | 8.12 | 13986.59 | 1721.74 | 1.00 | 1.13 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.11 | 1260.24 | 1140.11 | 1.00 | 1.34 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.88 | 1000.08 | 1140.11 | 1.00 | 1.40 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 20698.70 | 24838.44 | 65.38 | 1.497 | 1.796 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.88 | 0.00994 | 23.42 | 0.01335 | 0.232 | 0.00 |
CORE_RETAIL | 91162.85 | 109395.42 | 68.35 | 6.601 | 7.921 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00963 | 23.42 | 0.01335 | 1.890 | 0.00 |
POINT_OF_SALE | 12537.85 | 15045.42 | 99.76 | 0.918 | 1.102 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00910 | 23.42 | 0.01335 | 0.178 | 0.00 |
FRONT_RETAIL | 9711.02 | 11653.23 | 77.27 | 0.731 | 0.877 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 23.89 | 23.89 | 0.00916 | 30.14 | 0.01335 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 30.20 | 100.00 | 0.00001 | 30.30 | 0.01335 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 27629.21 | 33155.05 | 87.28 | 1.197 | 1.436 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00759 | -16.30 | 0.00092 | 0.232 | 0.00 |
CORE_RETAIL | 66213.36 | 79456.04 | 49.65 | 2.833 | 3.400 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00747 | -16.30 | 0.00092 | 1.890 | 0.00 |
POINT_OF_SALE | 13456.95 | 16148.34 | 107.08 | 0.585 | 0.702 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00770 | -16.30 | 0.00092 | 0.178 | 0.00 |
FRONT_RETAIL | 13458.88 | 16150.66 | 107.09 | 0.585 | 0.702 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00770 | -16.30 | 0.00092 | 0.178 | 0.00 |
FRONT_ENTRY | 48566.40 | 58279.68 | 4856.64 | 2.137 | 2.564 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 21.11 | 21.00 | 0.00564 | -16.30 | 0.00092 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 1.83 | 1.83 | 1.44 | 1.44 | 1.8322 | 1.7961 | 1.8322 | 0.9803 | 1.0000 |
PSZ-AC:2 | 8.12 | 8.12 | 3.40 | 3.40 | 8.1235 | 7.9209 | 8.1235 | 0.9751 | 1.0000 |
PSZ-AC:3 | 1.11 | 1.11 | 0.70 | 0.70 | 1.1054 | 1.1017 | 1.1054 | 0.9967 | 1.0000 |
PSZ-AC:4 | 0.88 | 0.88 | 0.70 | 0.70 | 0.8772 | 0.8772 | 0.8772 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 58327.706 | 58327.706 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 58327.71 | 58327.71 | 2.564068 | 20.79 | 12.24 | 0.00561075 | 40.00 | 20.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 0.0000 | 21.00 | 0.00563679 | 35.6657 | 58279.68 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 35529.440 | 0.000 | 1.832160 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 35529.44 | 28308.36 | 1.832160 | 24.76 | 17.53 | 0.00988468 | 12.80 | 11.87 | 0.00850000 | 30.30 | 0.01334551 | 21.80 | 12.6390 | 23.88 | 0.00994084 | 52.4113 | 20698.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 50543.163 | 50543.163 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 50543.16 | 50543.16 | 1.832163 | 14.94 | 10.74 | 0.00651842 | 40.00 | 20.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 12.6390 | 21.11 | 0.00759396 | 47.5726 | 27629.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 169703.930 | 0.000 | 8.123520 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 169703.93 | 130443.06 | 8.123520 | 25.47 | 18.03 | 0.01021812 | 12.80 | 11.87 | 0.00850000 | 30.30 | 0.01334551 | 21.80 | 23.2684 | 23.89 | 0.00963460 | 50.8193 | 84971.79 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 261764.523 | 261764.523 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 261764.52 | 261764.52 | 8.123517 | 0.20 | 0.05 | 0.00383037 | 40.00 | 20.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 23.2684 | 21.11 | 0.00746905 | 46.7984 | 66213.36 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 21157.850 | 0.000 | 1.105370 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 21157.85 | 17303.89 | 1.105370 | 24.92 | 17.45 | 0.00972333 | 12.80 | 11.87 | 0.00850000 | 30.30 | 0.01334551 | 21.80 | 16.1132 | 23.89 | 0.00909655 | 48.0170 | 12215.85 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 32592.857 | 32592.857 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32592.86 | 32592.86 | 1.105370 | 11.49 | 8.64 | 0.00597943 | 40.00 | 20.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 16.1132 | 21.11 | 0.00769848 | 48.2187 | 13456.95 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 17646.130 | 0.000 | 0.877180 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 17646.13 | 13897.45 | 0.877180 | 25.19 | 17.77 | 0.01001028 | 12.80 | 11.87 | 0.00850000 | 30.30 | 0.01334551 | 21.80 | 20.3049 | 23.89 | 0.00915913 | 48.3409 | 9700.58 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 27545.693 | 27545.693 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 27545.69 | 27545.69 | 0.877180 | 11.49 | 8.65 | 0.00597974 | 40.00 | 20.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 20.3049 | 21.11 | 0.00769856 | 48.2192 | 13458.88 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 58327.706 | 58327.706 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 2.564068 | 3.01002472 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 58327.71 | 58327.71 | 1.0000 | 3.01002472 | 2.564068 | 20.79 | 12.24 | 0.00561075 | 35140.2 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 58327.71 | -16.30 | 0.00092409 | -16.30 | 0.00000000 | 0.0000 | 21.01 | 0.00563679 | 21.00 | 0.00563679 | 35.6657 | 58279.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 35529.440 | 0.000 | 1.832160 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.2151 | 1004.8586 | 1.1739 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 35529.44 | 28308.36 | 1.0000 | 2.15081900 | 1.832160 | 24.76 | 17.53 | 0.00988468 | 50056.4 | 12.80 | 11.87 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35529.44 | 30.30 | 0.01334551 | 21.80 | 0.23156651 | 12.6390 | 23.89 | 0.00933933 | 23.88 | 0.00994084 | 52.4113 | 20698.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 50543.163 | 50543.163 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.832163 | 2.15082282 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 50543.16 | 50543.16 | 1.0000 | 2.15082282 | 1.832163 | 14.94 | 10.74 | 0.00651842 | 31495.6 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 50543.16 | -16.30 | 0.00092409 | -16.30 | 0.23156651 | 12.6390 | 20.95 | 0.00759396 | 21.11 | 0.00759396 | 47.5726 | 27629.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 169703.930 | 0.000 | 8.123520 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8350 | 1004.8586 | 1.1739 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 169703.93 | 130443.06 | 1.0000 | 9.53640576 | 8.123520 | 25.47 | 18.03 | 0.01021812 | 51628.9 | 12.80 | 11.87 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 169703.93 | 30.30 | 0.01334551 | 21.80 | 1.89021192 | 23.2684 | 23.89 | 0.00919628 | 23.89 | 0.00963460 | 50.8193 | 84971.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 261764.523 | 261764.523 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 8.123517 | 9.53640178 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 261764.52 | 261764.52 | 1.0000 | 9.53640178 | 8.123517 | 0.20 | 0.05 | 0.00383037 | 9778.5 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 261764.52 | -16.30 | 0.00092409 | -16.30 | 1.89021192 | 23.2684 | 20.85 | 0.00746905 | 21.11 | 0.00746905 | 46.7984 | 66213.36 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21157.850 | 0.000 | 1.105370 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.9152 | 1004.8586 | 1.1739 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 21157.85 | 17303.89 | 1.0000 | 1.29762182 | 1.105370 | 24.92 | 17.45 | 0.00972333 | 49811.4 | 12.80 | 11.87 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21157.85 | 30.30 | 0.01334551 | 21.80 | 0.17811053 | 16.1132 | 23.89 | 0.00902612 | 23.89 | 0.00909655 | 48.0170 | 12215.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 32592.857 | 32592.857 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.105370 | 1.29762183 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32592.86 | 32592.86 | 1.0000 | 1.29762183 | 1.105370 | 11.49 | 8.64 | 0.00597943 | 26628.4 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 32592.86 | -16.30 | 0.00092409 | -16.30 | 0.17811053 | 16.1132 | 20.94 | 0.00769848 | 21.11 | 0.00769848 | 48.2187 | 13456.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17646.130 | 0.000 | 0.877180 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.4486 | 1004.8586 | 1.1739 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 17646.13 | 13897.45 | 1.0000 | 1.02974381 | 0.877180 | 25.19 | 17.77 | 0.01001028 | 50817.0 | 12.80 | 11.87 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17646.13 | 30.30 | 0.01334551 | 21.80 | 0.17811053 | 20.3049 | 23.89 | 0.00915938 | 23.89 | 0.00915913 | 48.3409 | 9700.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27545.693 | 27545.693 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.877180 | 1.02974382 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 27545.69 | 27545.69 | 1.0000 | 1.02974382 | 0.877180 | 11.49 | 8.65 | 0.00597974 | 26630.5 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27545.69 | -16.30 | 0.00092409 | -16.30 | 0.17811053 | 20.3049 | 20.94 | 0.00769856 | 21.11 | 0.00769856 | 48.2192 | 13458.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:2_OA_CONTROLLER | DifferentialDryBulb | 1.89 | 8.12 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2625.17 | 3492.83 | 1809.50 |
CORE_RETAIL | 2443.67 | 2823.00 | 1086.33 |
POINT_OF_SALE | 2612.00 | 2854.83 | 1261.17 |
FRONT_RETAIL | 2708.83 | 3217.00 | 1560.33 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3276.17 | 3529.33 | 1840.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 76.17 | 2.00 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 32.33 | 0.00 | 0.00 |
POINT_OF_SALE | 58.83 | 22.33 | 0.00 | 0.00 |
FRONT_RETAIL | 74.50 | 2.50 | 0.00 | 0.00 |
FRONT_ENTRY | 0.33 | 0.00 | 0.00 | 0.00 |
Facility | 108.17 | 57.17 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.42 | 61.34 | 2317.33 | 0.365 | 0.071 | 0.000 | 0.000 |
CORE_RETAIL | 128.15 | 258.43 | 9762.95 | 0.744 | 0.014 | 0.000 | 0.000 |
POINT_OF_SALE | 12.08 | 24.35 | 919.94 | 0.708 | 0.078 | 0.000 | 0.000 |
FRONT_RETAIL | 12.08 | 24.35 | 919.94 | 0.707 | 0.078 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.42 | 61.34 | 2317.33 | 0.350 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.15 | 258.43 | 9762.95 | 0.677 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.08 | 24.35 | 919.94 | 0.676 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.08 | 24.35 | 919.94 | 0.677 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 11 | 11 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
Electricity:Building | 687.20 | 3715.40 | 01-JAN-00:10 | 45335.16 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 93.95 | 631.39 | 01-JAN-00:10 | 5846.82 | 02-JAN-09:10 |
InteriorLights:Electricity | 492.05 | 1920.23 | 01-JAN-00:10 | 34564.13 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 43.96 | 171.54 | 01-JAN-00:10 | 3087.68 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 492.05 | 1920.23 | 01-JAN-00:10 | 34564.13 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 459.53 | 2239.77 | 01-JAN-00:10 | 31010.61 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 375.23 | 1464.33 | 01-JAN-00:10 | 26358.01 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 88.28 | 624.80 | 01-JAN-00:10 | 5404.55 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 35.36 | 137.98 | 01-JAN-00:10 | 2483.66 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 43.30 | 211.05 | 01-JAN-00:10 | 2922.06 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 35.36 | 137.98 | 01-JAN-00:10 | 2483.66 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 2.15 | 8.40 | 01-JAN-00:10 | 151.13 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 2.15 | 8.40 | 01-JAN-00:10 | 151.13 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
ElectricityPurchased:Plant | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
Cogeneration:ElectricityPurchased | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
ElectricityNet:Plant | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
Cogeneration:ElectricityNet | 1348.81 | 3715.40 | 12-MAR-18:10 | 113660.37 | 15-JUL-14:40 |
Electricity:HVAC | 546.62 | 0.00 | 01-JAN-00:50 | 68325.21 | 15-JUL-14:40 |
Fans:Electricity | 387.65 | 0.00 | 01-JAN-00:50 | 21058.62 | 01-JAN-13:20 |
General:Fans:Electricity | 387.65 | 0.00 | 01-JAN-00:50 | 21058.62 | 01-JAN-13:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 158.97 | 0.00 | 01-JAN-00:10 | 50072.97 | 15-JUL-14:40 |
ExteriorLights:Electricity | 114.99 | 0.00 | 01-JAN-08:00 | 7321.52 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 114.99 | 0.00 | 01-JAN-08:00 | 7321.52 | 01-JAN-00:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 668.20 | 1862.00 | 23-JAN-21:10 | 247771.69 | 07-FEB-07:10 |
Gas:Plant | 98.75 | 1862.00 | 05-JAN-05:30 | 5478.41 | 16-FEB-13:00 |
WaterSystems:Gas | 98.75 | 1862.00 | 05-JAN-05:30 | 5478.41 | 16-FEB-13:00 |
Water Heater:WaterSystems:Gas | 98.75 | 1862.00 | 05-JAN-05:30 | 5478.41 | 16-FEB-13:00 |
Gas:HVAC | 569.45 | 0.00 | 01-JAN-00:10 | 243182.45 | 07-FEB-07:10 |
Heating:Gas | 569.45 | 0.00 | 01-JAN-00:10 | 243182.45 | 07-FEB-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1712.41 | 0.00 | 01-JAN-00:50 | 315526.38 | 07-FEB-07:10 |
EnergyTransfer:Building | 729.50 | 0.00 | 01-JAN-00:50 | 140829.15 | 06-FEB-05:10 |
EnergyTransfer:Zone:BACK_SPACE | 100.81 | 0.00 | 01-JAN-00:10 | 45402.74 | 22-FEB-05:20 |
Heating:EnergyTransfer | 237.14 | 0.00 | 01-JAN-00:50 | 140829.15 | 06-FEB-05:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 53.89 | 0.00 | 01-JAN-00:10 | 45402.74 | 22-FEB-05:20 |
Cooling:EnergyTransfer | 492.37 | 0.00 | 01-JAN-00:10 | 79437.28 | 21-JUL-14:10 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 46.92 | 0.00 | 01-JAN-00:10 | 12374.46 | 21-JUL-14:10 |
EnergyTransfer:Zone:CORE_RETAIL | 392.65 | 0.00 | 01-JAN-00:10 | 84005.02 | 06-FEB-07:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 32.65 | 0.00 | 01-JAN-00:10 | 81809.91 | 10-JAN-06:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 360.00 | 0.00 | 01-JAN-00:10 | 50839.06 | 21-JUL-14:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 67.56 | 0.00 | 01-JAN-00:10 | 23796.68 | 12-JAN-05:20 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 13.37 | 0.00 | 01-JAN-00:10 | 23796.68 | 12-JAN-05:20 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 54.20 | 0.00 | 01-JAN-00:10 | 10009.97 | 21-SEP-13:30 |
EnergyTransfer:Zone:FRONT_RETAIL | 52.86 | 0.00 | 01-JAN-00:10 | 21799.15 | 13-FEB-05:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 21.61 | 0.00 | 01-JAN-00:10 | 21799.15 | 13-FEB-05:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 31.25 | 0.00 | 01-JAN-00:10 | 7881.14 | 21-SEP-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 115.61 | 0.00 | 01-JAN-00:50 | 45845.99 | 06-FEB-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 115.61 | 0.00 | 01-JAN-00:50 | 45845.99 | 06-FEB-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 19.06 | 01-FEB-05:10 |
EnergyTransfer:HVAC | 982.91 | 0.00 | 01-JAN-00:10 | 193294.35 | 07-FEB-07:10 |
HeatingCoils:EnergyTransfer | 453.65 | 0.00 | 01-JAN-00:10 | 193294.35 | 07-FEB-07:10 |
CoolingCoils:EnergyTransfer | 529.26 | 0.00 | 01-JAN-00:10 | 168567.11 | 20-JUL-14:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 53.894 | -46.919 | 0.000 | 0.000 | 39.682 | 43.956 | 49.992 | 0.000 | 0.000 | 0.297 | 0.001 | 0.000 | 0.000 | 0.000 | -42.967 | -97.934 |
CORE_RETAIL | 0.000 | 0.000 | 32.650 | -360.001 | 0.000 | 0.000 | 165.844 | 375.227 | 84.299 | 10.954 | 0.000 | 0.243 | 0.000 | 0.000 | -11.353 | 0.000 | -38.316 | -259.547 |
POINT_OF_SALE | 0.000 | 0.000 | 13.369 | -54.195 | 0.000 | 0.000 | 15.524 | 35.357 | 52.922 | 26.984 | 0.000 | 0.129 | 0.000 | 0.000 | -24.092 | 0.000 | -19.234 | -46.764 |
FRONT_RETAIL | 0.000 | 0.000 | 21.612 | -31.248 | 0.000 | 0.000 | 15.786 | 35.357 | 7.943 | 27.103 | 0.000 | 0.129 | 0.000 | 0.000 | -23.495 | 0.000 | -18.671 | -34.515 |
FRONT_ENTRY | 115.612 | -0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 2.151 | 0.000 | 5.468 | 0.000 | 0.038 | 0.000 | 0.000 | -4.831 | 0.000 | -116.887 | -1.550 |
Total Facility | 115.612 | -0.000 | 121.524 | -492.363 | 0.000 | 0.000 | 236.835 | 492.048 | 195.156 | 70.510 | 0.000 | 0.835 | 0.002 | 0.000 | -63.771 | 0.000 | -236.075 | -440.311 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 20-JUL-21:40 | 0.00 | 0.00 | 0.00 | -16457.85 | 0.00 | 0.00 | 0.00 | 171.54 | 613.14 | 0.00 | 0.00 | 219.63 | 15453.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 10-SEP-19:20 | 0.00 | 0.00 | 0.00 | -94712.37 | 0.00 | 0.00 | 0.00 | 1464.33 | 775.43 | 0.00 | 0.00 | 0.00 | 93000.05 | 0.00 | -527.45 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 10-AUG-20:43 | 0.00 | 0.00 | 0.00 | -15491.51 | 0.00 | 0.00 | 0.00 | 551.92 | 649.09 | 0.00 | 0.00 | 139.51 | 14172.69 | 0.00 | -21.70 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 10-AUG-20:43 | 0.00 | 0.00 | 0.00 | -12490.98 | 0.00 | 0.00 | 0.00 | 551.92 | 97.42 | 0.00 | 0.00 | 141.51 | 11708.69 | 0.00 | -8.57 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | 01-FEB-05:02 | 0.00 | -190.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 424.33 | 0.00 | -154.36 | 0.00 | -87.74 | 0.00 |
Total Facility | 12-AUG-05:02 | 0.00 | 0.00 | 0.00 | -98496.83 | 0.00 | 0.00 | 0.00 | 1920.23 | 1795.17 | 0.00 | 0.00 | 0.00 | 98177.75 | 0.00 | -2945.61 | 0.00 | -450.72 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 13-MAR-04:01 | 0.00 | 0.00 | 49299.49 | 0.00 | 0.00 | 0.00 | 0.00 | 171.54 | 613.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -2173.86 | -47910.31 |
CORE_RETAIL | 11-DEC-05:01 | 0.00 | 0.00 | 268822.71 | 0.00 | 0.00 | 0.00 | 0.00 | 1464.33 | 1033.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1225.02 | 0.00 | -1925.50 | -268170.44 |
POINT_OF_SALE | 13-MAR-04:01 | 0.00 | 0.00 | 30914.96 | 0.00 | 0.00 | 0.00 | 0.00 | 137.98 | 649.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -747.41 | 0.00 | -1102.50 | -29852.11 |
FRONT_RETAIL | 13-MAR-04:01 | 0.00 | 0.00 | 26183.84 | 0.00 | 0.00 | 0.00 | 0.00 | 137.98 | 97.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -687.51 | 0.00 | -980.74 | -24751.00 |
FRONT_ENTRY | 06-FEB-18:00 | 45845.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -613.41 | 0.00 | -45284.22 | -98.81 |
Total Facility | 13-FEB-05:01 | 7903.98 | 0.00 | 364596.35 | 0.00 | 0.00 | 0.00 | 0.00 | 1920.23 | 2393.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5470.60 | 0.00 | -35836.22 | -335507.31 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.7961 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.8322 | 0.1264 | 1.0000 | 0.2316 | 0.1264 | ||
PSZ-AC:2 | 7.9209 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 8.1235 | 0.2327 | 1.0000 | 1.8902 | 0.2327 | ||
PSZ-AC:3 | 1.1017 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1054 | 0.1611 | 1.0000 | 0.1781 | 0.1611 | ||
PSZ-AC:4 | 0.8772 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8772 | 0.2030 | 1.0000 | 0.1781 | 0.2030 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.7961 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.7961 | 1.0000 | 1.0000 | 0.2316 | 0.1289 | ||
PSZ-AC:2 | 7.9209 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.9209 | 1.0000 | 1.0000 | 1.8902 | 0.2386 | ||
PSZ-AC:3 | 1.1017 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1017 | 1.0000 | 1.0000 | 0.1781 | 0.1617 | ||
PSZ-AC:4 | 0.8772 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8772 | 1.0000 | 1.0000 | 0.1781 | 0.2030 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.7961 | 1.7961 | 1.7961 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.9209 | 7.9209 | 7.9209 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1017 | 1.1017 | 1.1017 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8772 | 0.8772 | 0.8772 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.7961 | 1.8322 | 1.7961 | 1.7961 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.9209 | 8.1235 | 7.9209 | 7.9209 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1017 | 1.1054 | 1.1017 | 1.1017 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8772 | 0.8772 | 0.8772 | 0.8772 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.7961 | 1.7961 | 1.7961 | 0.2316 | 0.1613 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.9209 | 7.9209 | 7.9209 | 1.8902 | 0.5560 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1017 | 1.1017 | 1.1017 | 0.1781 | 0.2538 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8772 | 0.8772 | 0.8772 | 0.1781 | 0.2537 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.7961 | 1.7961 | 1.7961 | 1.7961 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.9209 | 7.9209 | 7.9209 | 7.9209 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1017 | 1.1017 | 1.1017 | 1.1017 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8772 | 0.8772 | 0.8772 | 0.8772 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 569.45 | 243182.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 158.97 | 50072.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 492.05 | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 114.99 | 7321.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 387.65 | 21058.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 98.75 | 5478.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 1348.81 |
Natural Gas | 0.00 | 668.20 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 2017.01 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 214.49 |
Space Heating | 0.00 |
Space Cooling | 69.30 |
Fans (All) | 168.99 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 587.98 |
Subtotal | 587.98 |
Natural Gas [MJ/m2] | |
Space Heating | 248.23 |
Service Water Heating | 43.05 |
Miscellaneous (All) | 291.28 |
Subtotal | 291.28 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 24.39 |
Space Heating | 28.23 |
Space Cooling | 7.88 |
Fans (All) | 19.22 |
Service Water Heating | 4.90 |
Receptacle Equipment | 9.68 |
Miscellaneous | 5.70 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3609. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_SETBACK | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
HTGSETP_SCH_PSZ_AC_2 | CORE_RETAIL DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2007
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.148948E+12 |
February | 0.000 | 0.141970E+12 |
March | 0.000 | 0.737451E+11 |
April | 0.000 | 0.239267E+11 |
May | 0.000 | 0.316975E+10 |
June | 0.000 | 0.360621E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.697058E+08 |
September | 0.000 | 0.533847E+09 |
October | 0.000 | 0.103908E+11 |
November | 0.000 | 0.337166E+11 |
December | 0.000 | 0.132616E+12 |
Annual Sum or Average | 0.569447E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.148948E+12 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3193916.67 | 4623.11 | 10-JAN-06:07 | -13.0 | -14.0 | 0.165230E+10 | 1854.44 | 18-JAN-15:09 | 2.20 | 1.51 |
February | 9005210.18 | 7650.04 | 21-FEB-06:06 | -13.4 | -14.1 | 0.150876E+10 | 1854.44 | 02-FEB-15:50 | -3.3 | -4.3 |
March | 0.704992E+09 | 4538.87 | 15-MAR-14:20 | 25.93 | 16.10 | 0.180287E+10 | 2451.26 | 17-MAR-14:09 | 10.95 | 8.47 |
April | 0.128520E+10 | 3025.23 | 10-APR-16:00 | 3.30 | 2.84 | 0.183011E+10 | 2451.25 | 07-APR-14:09 | 19.72 | 10.07 |
May | 0.320868E+10 | 6778.31 | 27-MAY-15:40 | 21.70 | 12.04 | 0.217480E+10 | 2451.32 | 27-MAY-10:39 | 19.43 | 12.20 |
June | 0.813310E+10 | 13668.12 | 25-JUN-18:20 | 26.33 | 18.04 | 0.219585E+10 | 2451.32 | 03-JUN-12:00 | 18.30 | 11.64 |
July | 0.115210E+11 | 16458.42 | 20-JUL-21:40 | 25.20 | 23.91 | 0.218700E+10 | 2451.27 | 06-JUL-14:00 | 21.70 | 12.62 |
August | 0.110626E+11 | 15506.33 | 09-AUG-21:00 | 23.90 | 17.55 | 0.228047E+10 | 2451.29 | 03-AUG-14:30 | 26.95 | 15.52 |
September | 0.680817E+10 | 12484.74 | 17-SEP-07:03 | 22.12 | 19.56 | 0.214525E+10 | 2451.32 | 19-SEP-14:50 | 20.92 | 13.01 |
October | 0.279073E+10 | 5688.25 | 05-OCT-15:00 | 18.90 | 12.66 | 0.201670E+10 | 2451.27 | 31-OCT-14:00 | 13.90 | 10.58 |
November | 0.126843E+10 | 3097.57 | 28-NOV-15:10 | 2.20 | 0.75 | 0.168501E+10 | 2453.56 | 04-NOV-13:50 | 17.62 | 13.73 |
December | 0.124823E+09 | 3041.64 | 21-DEC-12:40 | 0.60 | 0.13 | 0.165658E+10 | 1877.03 | 01-DEC-15:09 | 7.20 | 5.58 |
Annual Sum or Average | 0.469199E+11 | 0.231357E+11 | ||||||||
Minimum of Months | 3193916.67 | 3025.23 | -13.4 | -14.1 | 0.150876E+10 | 1854.44 | -3.3 | -4.3 | ||
Maximum of Months | 0.115210E+11 | 16458.42 | 26.33 | 23.91 | 0.228047E+10 | 2453.56 | 26.95 | 15.52 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.889183E+10 | 60609.82 | 06-JAN-07:05 | -12.4 | -13.0 | 0.696749E+10 | 8583.29 | 11-JAN-15:00 | 11.70 | 10.13 |
February | 0.893065E+10 | 59798.79 | 05-FEB-09:05 | -11.7 | -12.3 | 0.636314E+10 | 8473.40 | 22-FEB-15:00 | 10.60 | 5.00 |
March | 0.199475E+11 | 59594.18 | 07-MAR-07:05 | -12.9 | -13.7 | 0.776733E+10 | 10327.16 | 17-MAR-14:20 | 10.20 | 7.87 |
April | 0.242784E+11 | 33885.30 | 22-APR-06:03 | 1.05 | 0.38 | 0.817583E+10 | 10327.23 | 29-APR-14:50 | 10.05 | 8.56 |
May | 0.347279E+11 | 71298.89 | 31-MAY-21:23 | 17.70 | 13.04 | 0.933142E+10 | 10327.53 | 27-MAY-10:20 | 18.87 | 12.08 |
June | 0.492124E+11 | 78936.96 | 03-JUN-05:02 | 11.10 | 8.26 | 0.926784E+10 | 10327.68 | 10-JUN-13:39 | 21.10 | 13.59 |
July | 0.572668E+11 | 81692.09 | 12-JUL-05:02 | 12.48 | 10.81 | 0.921480E+10 | 10327.09 | 15-JUL-11:20 | 22.20 | 21.11 |
August | 0.556387E+11 | 91087.26 | 12-AUG-05:02 | 12.80 | 11.91 | 0.960905E+10 | 10327.38 | 16-AUG-14:39 | 26.33 | 15.78 |
September | 0.413534E+11 | 94712.37 | 10-SEP-19:20 | 13.87 | 9.80 | 0.906413E+10 | 10327.44 | 19-SEP-14:00 | 21.10 | 13.28 |
October | 0.280531E+11 | 65980.93 | 05-OCT-20:33 | 16.10 | 12.52 | 0.869999E+10 | 10327.17 | 21-OCT-10:20 | 16.67 | 12.25 |
November | 0.208131E+11 | 31581.35 | 15-NOV-07:05 | -0.6 | -1.0 | 0.734379E+10 | 10327.10 | 04-NOV-11:09 | 15.18 | 12.50 |
December | 0.108885E+11 | 58863.48 | 10-DEC-09:05 | -11.4 | -11.8 | 0.700229E+10 | 8589.72 | 01-DEC-13:09 | 12.97 | 11.33 |
Annual Sum or Average | 0.360002E+12 | 0.988071E+11 | ||||||||
Minimum of Months | 0.889183E+10 | 31581.35 | -12.9 | -13.7 | 0.636314E+10 | 8473.40 | 10.05 | 5.00 | ||
Maximum of Months | 0.572668E+11 | 94712.37 | 17.70 | 13.04 | 0.960905E+10 | 10327.68 | 26.33 | 21.11 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.103163E+10 | 5282.29 | 30-JAN-18:33 | -12.2 | -13.3 | 0.658061E+09 | 818.39 | 11-JAN-15:00 | 11.70 | 10.13 |
February | 0.996960E+09 | 5499.81 | 14-FEB-06:05 | -9.4 | -9.9 | 0.605146E+09 | 919.61 | 22-FEB-15:00 | 10.60 | 5.00 |
March | 0.267721E+10 | 7359.85 | 15-MAR-13:40 | 25.73 | 15.89 | 0.759895E+09 | 973.17 | 15-MAR-14:00 | 25.60 | 16.22 |
April | 0.289175E+10 | 5422.26 | 22-APR-13:40 | 15.20 | 6.91 | 0.780852E+09 | 973.16 | 08-APR-13:50 | 20.68 | 13.71 |
May | 0.440159E+10 | 5945.94 | 27-MAY-16:00 | 21.70 | 11.99 | 0.874705E+09 | 973.15 | 15-MAY-14:00 | 17.20 | 11.67 |
June | 0.702794E+10 | 10703.53 | 27-JUN-20:10 | 23.62 | 21.83 | 0.872189E+09 | 973.17 | 23-JUN-14:00 | 18.90 | 13.36 |
July | 0.914981E+10 | 13330.46 | 19-JUL-20:10 | 27.12 | 22.12 | 0.868167E+09 | 973.18 | 12-JUL-14:20 | 22.20 | 15.26 |
August | 0.957625E+10 | 15493.18 | 10-AUG-20:43 | 26.02 | 18.62 | 0.905327E+09 | 973.18 | 19-AUG-15:20 | 23.13 | 15.97 |
September | 0.773869E+10 | 12021.62 | 21-SEP-20:10 | 19.72 | 17.01 | 0.853659E+09 | 973.19 | 09-SEP-14:09 | 22.43 | 15.69 |
October | 0.482910E+10 | 9328.27 | 11-OCT-12:40 | 22.03 | 13.89 | 0.840578E+09 | 973.17 | 21-OCT-10:20 | 16.67 | 12.25 |
November | 0.279316E+10 | 5748.95 | 01-NOV-12:00 | 11.10 | 6.26 | 0.728845E+09 | 973.12 | 27-NOV-15:20 | 10.60 | 8.39 |
December | 0.108099E+10 | 4844.04 | 26-DEC-16:53 | -10.0 | -11.3 | 0.666209E+09 | 973.08 | 16-DEC-14:39 | 5.20 | 2.73 |
Annual Sum or Average | 0.541951E+11 | 0.941363E+10 | ||||||||
Minimum of Months | 0.996960E+09 | 4844.04 | -12.2 | -13.3 | 0.605146E+09 | 818.39 | 5.20 | 2.73 | ||
Maximum of Months | 0.957625E+10 | 15493.18 | 27.12 | 22.12 | 0.905327E+09 | 973.19 | 25.60 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.168615E+09 | 5329.15 | 29-JAN-08:06 | -8.1 | -9.4 | 0.655932E+09 | 736.18 | 07-JAN-14:50 | -1.5 | -3.2 |
February | 0.235675E+09 | 4039.79 | 25-FEB-06:05 | -8.4 | -9.2 | 0.599217E+09 | 774.04 | 22-FEB-15:50 | 10.60 | 4.98 |
March | 0.119927E+10 | 4997.81 | 15-MAR-13:40 | 25.73 | 15.89 | 0.717259E+09 | 973.09 | 16-MAR-14:50 | 19.32 | 15.74 |
April | 0.144846E+10 | 3278.13 | 22-APR-13:40 | 15.20 | 6.91 | 0.721879E+09 | 973.13 | 20-APR-14:50 | 14.22 | 10.67 |
May | 0.214259E+10 | 3819.95 | 23-MAY-14:50 | 23.90 | 13.32 | 0.845608E+09 | 973.13 | 27-MAY-10:39 | 19.43 | 12.20 |
June | 0.420134E+10 | 6532.63 | 25-JUN-18:15 | 26.33 | 18.04 | 0.867141E+09 | 973.15 | 10-JUN-13:39 | 21.10 | 13.59 |
July | 0.608519E+10 | 10499.87 | 19-JUL-20:10 | 27.12 | 22.12 | 0.867552E+09 | 973.10 | 15-JUL-11:20 | 22.20 | 21.11 |
August | 0.640384E+10 | 12492.00 | 10-AUG-20:43 | 26.02 | 18.62 | 0.904213E+09 | 973.14 | 08-AUG-14:00 | 27.80 | 17.10 |
September | 0.497675E+10 | 8820.83 | 21-SEP-20:10 | 19.72 | 17.01 | 0.846300E+09 | 973.16 | 22-SEP-14:00 | 23.90 | 15.45 |
October | 0.291022E+10 | 6992.12 | 11-OCT-14:30 | 22.20 | 14.36 | 0.789730E+09 | 973.15 | 31-OCT-14:00 | 13.90 | 10.58 |
November | 0.126966E+10 | 3310.98 | 01-NOV-12:30 | 11.40 | 6.61 | 0.678734E+09 | 973.10 | 16-NOV-15:09 | 17.20 | 13.32 |
December | 0.207220E+09 | 4918.79 | 27-DEC-12:02 | -8.7 | -10.5 | 0.658315E+09 | 835.05 | 16-DEC-14:09 | 5.50 | 2.81 |
Annual Sum or Average | 0.312488E+11 | 0.915188E+10 | ||||||||
Minimum of Months | 0.168615E+09 | 3278.13 | -8.7 | -10.5 | 0.599217E+09 | 736.18 | -1.5 | -3.2 | ||
Maximum of Months | 0.640384E+10 | 12492.00 | 27.12 | 22.12 | 0.904213E+09 | 973.16 | 27.80 | 21.11 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 19603.01 | 177.13 | 17-JAN-05:02 | 7.70 | 3.07 | 0.00 | 0.00 | 01-JAN-00:10 | -1.0 | -1.6 |
February | 28003.86 | 190.63 | 01-FEB-05:02 | 7.20 | 6.89 | 0.00 | 0.00 | 01-FEB-00:10 | -3.3 | -4.6 |
March | 80264.55 | 153.93 | 10-MAR-05:02 | 2.20 | 2.20 | 0.00 | 0.00 | 01-MAR-00:10 | -4.9 | -6.8 |
April | 44298.80 | 160.62 | 17-APR-04:02 | -3.4 | -4.9 | 0.00 | 0.00 | 01-APR-00:10 | 4.10 | 3.71 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 | 6.11 | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 | 6.11 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 | 14.03 | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 | 14.03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 | 13.49 | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 | 13.49 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 18.85 | 16.93 | 0.00 | 0.00 | 01-AUG-00:10 | 18.85 | 16.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 | 12.90 | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 | 12.90 |
October | 7454.33 | 124.24 | 30-OCT-04:02 | -0.5 | -1.1 | 0.00 | 0.00 | 01-OCT-00:10 | 14.42 | 12.27 |
November | 83937.98 | 171.91 | 12-NOV-07:02 | 1.02 | -0.9 | 0.00 | 0.00 | 01-NOV-00:10 | 6.53 | 4.43 |
December | 57399.79 | 129.82 | 14-DEC-05:02 | 5.60 | 5.09 | 0.00 | 0.00 | 01-DEC-00:10 | 4.95 | 3.06 |
Annual Sum or Average | 320962.32 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -3.4 | -4.9 | 0.00 | 0.00 | -4.9 | -6.8 | ||
Maximum of Months | 83937.98 | 190.63 | 18.85 | 16.93 | 0.00 | 0.00 | 18.85 | 16.93 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.139959E+11 | 48952.56 | 17-JAN-05:01 | 7.70 |
February | 0.140536E+11 | 48925.36 | 01-FEB-05:01 | 7.20 |
March | 0.752031E+10 | 49299.62 | 13-MAR-04:01 | 10.73 |
April | 0.267611E+10 | 48273.41 | 04-APR-04:01 | 7.88 |
May | 0.192884E+09 | 46653.27 | 02-MAY-04:02 | 6.78 |
June | 8569482.90 | 2051.15 | 18-JUN-07:10 | 23.48 |
July | 8826926.98 | 3063.65 | 21-JUL-05:05 | 25.60 |
August | 5930930.38 | 1942.35 | 14-AUG-05:10 | 22.80 |
September | 6846305.89 | 2251.07 | 30-SEP-05:02 | 7.20 |
October | 0.656054E+09 | 47847.01 | 31-OCT-04:02 | 9.32 |
November | 0.284874E+10 | 48637.73 | 26-NOV-07:01 | 10.10 |
December | 0.119197E+11 | 48822.38 | 01-DEC-05:01 | 9.08 |
Annual Sum or Average | 0.538935E+11 | |||
Minimum of Months | 5930930.38 | 1942.35 | 6.78 | |
Maximum of Months | 0.140536E+11 | 49299.62 | 25.60 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.852262E+10 | 268768.72 | 30-JAN-05:01 | -9.5 |
February | 0.810582E+10 | 268796.09 | 06-FEB-05:01 | -14.8 |
March | 0.375272E+10 | 266088.90 | 07-MAR-06:01 | -13.3 |
April | 0.155609E+10 | 109846.39 | 17-APR-05:03 | -4.0 |
May | 0.598137E+09 | 15096.76 | 28-MAY-07:05 | 17.88 |
June | 0.105273E+09 | 15511.01 | 03-JUN-05:04 | 11.10 |
July | 96652009.13 | 16761.08 | 17-JUL-05:05 | 22.80 |
August | 0.110765E+09 | 15845.42 | 12-AUG-05:04 | 12.80 |
September | 0.162245E+09 | 15318.42 | 26-SEP-05:05 | 15.50 |
October | 0.101224E+10 | 23028.09 | 17-OCT-06:10 | -2.8 |
November | 0.179190E+10 | 172726.77 | 24-NOV-06:03 | -3.8 |
December | 0.683535E+10 | 268822.71 | 11-DEC-05:01 | -17.5 |
Annual Sum or Average | 0.326498E+11 | |||
Minimum of Months | 96652009.13 | 15096.76 | -17.5 | |
Maximum of Months | 0.852262E+10 | 268822.71 | 22.80 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.351577E+10 | 30670.37 | 17-JAN-05:01 | 7.70 |
February | 0.383721E+10 | 30694.09 | 01-FEB-05:01 | 7.20 |
March | 0.154468E+10 | 30915.08 | 13-MAR-04:01 | 10.73 |
April | 0.618750E+09 | 30054.76 | 04-APR-04:01 | 7.88 |
May | 23749062.30 | 13233.83 | 07-MAY-06:02 | 4.78 |
June | 1473353.17 | 678.62 | 27-JUN-05:10 | 21.20 |
July | 1080883.74 | 707.40 | 16-JUL-07:10 | 23.48 |
August | 308904.17 | 341.23 | 30-AUG-05:10 | 19.82 |
September | 172640.63 | 264.36 | 16-SEP-05:10 | 21.20 |
October | 0.110388E+09 | 28892.56 | 09-OCT-06:01 | 2.20 |
November | 0.647896E+09 | 30338.00 | 14-NOV-05:01 | 7.07 |
December | 0.306743E+10 | 30689.41 | 01-DEC-05:01 | 9.08 |
Annual Sum or Average | 0.133689E+11 | |||
Minimum of Months | 172640.63 | 264.36 | 2.20 | |
Maximum of Months | 0.383721E+10 | 30915.08 | 23.48 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.556828E+10 | 25891.00 | 17-JAN-05:01 | 7.70 |
February | 0.570578E+10 | 25904.94 | 01-FEB-05:01 | 7.20 |
March | 0.247596E+10 | 26183.95 | 13-MAR-04:01 | 10.73 |
April | 0.118535E+10 | 25391.06 | 04-APR-04:01 | 7.88 |
May | 0.129417E+09 | 24402.89 | 02-MAY-04:02 | 6.78 |
June | 3660312.96 | 5831.47 | 14-JUN-04:53 | 6.70 |
July | 1315018.74 | 826.37 | 17-JUL-05:10 | 22.80 |
August | 365253.08 | 341.70 | 08-AUG-05:10 | 20.60 |
September | 3314881.03 | 8792.56 | 30-SEP-05:02 | 7.20 |
October | 0.318381E+09 | 24477.40 | 25-OCT-04:02 | 5.68 |
November | 0.119087E+10 | 25590.38 | 14-NOV-05:01 | 7.07 |
December | 0.502891E+10 | 25928.69 | 01-DEC-05:01 | 9.08 |
Annual Sum or Average | 0.216116E+11 | |||
Minimum of Months | 365253.08 | 341.70 | 5.68 | |
Maximum of Months | 0.570578E+10 | 26183.95 | 22.80 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.223468E+11 | 42360.29 | 31-JAN-18:00 | -12.2 |
February | 0.208879E+11 | 45845.99 | 06-FEB-18:00 | -14.4 |
March | 0.152897E+11 | 37232.15 | 06-MAR-18:00 | -8.3 |
April | 0.930447E+10 | 29549.82 | 16-APR-11:10 | -3.1 |
May | 0.389471E+10 | 13776.17 | 11-MAY-17:00 | 8.90 |
June | 0.110779E+10 | 14416.64 | 13-JUN-11:03 | 10.00 |
July | 32118557.22 | 3190.13 | 02-JUL-11:10 | 18.48 |
August | 0.264550E+09 | 7460.97 | 31-AUG-11:10 | 14.60 |
September | 0.160219E+10 | 11627.10 | 28-SEP-17:00 | 10.60 |
October | 0.770815E+10 | 19798.19 | 24-OCT-11:10 | 4.50 |
November | 0.117556E+11 | 24872.30 | 23-NOV-18:00 | 0.60 |
December | 0.214184E+11 | 43386.72 | 10-DEC-18:00 | -12.8 |
Annual Sum or Average | 0.115612E+12 | |||
Minimum of Months | 32118557.22 | 3190.13 | -14.4 | |
Maximum of Months | 0.223468E+11 | 45845.99 | 18.48 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.368607E+10 | 3087.68 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.335384E+10 | 3087.68 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.382564E+10 | 3087.68 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.360950E+10 | 3087.68 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.375586E+10 | 3087.68 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.369163E+10 | 3087.68 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.367372E+10 | 3087.68 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.382564E+10 | 3087.68 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.360950E+10 | 3087.68 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.368607E+10 | 3087.68 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.356442E+10 | 3087.68 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.367372E+10 | 3087.68 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.439556E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.335384E+10 | 3087.68 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.382564E+10 | 3087.68 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.314662E+11 | 26358.01 | 02-JAN-09:09 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.286301E+11 | 26358.01 | 01-FEB-09:09 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.326576E+11 | 26358.01 | 01-MAR-09:09 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.308125E+11 | 26358.01 | 01-APR-09:09 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.320619E+11 | 26358.01 | 01-MAY-08:09 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.315136E+11 | 26358.01 | 01-JUN-08:09 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.313608E+11 | 26358.01 | 01-JUL-09:09 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.326576E+11 | 26358.01 | 01-AUG-08:09 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.308125E+11 | 26358.01 | 01-SEP-08:09 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.314662E+11 | 26358.01 | 02-OCT-08:09 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.304277E+11 | 26358.01 | 01-NOV-08:09 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.313608E+11 | 26358.01 | 01-DEC-09:09 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.375227E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.286301E+11 | 26358.01 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.326576E+11 | 26358.01 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.296499E+10 | 2483.66 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.269775E+10 | 2483.66 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.307725E+10 | 2483.66 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.290340E+10 | 2483.66 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.302112E+10 | 2483.66 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.296946E+10 | 2483.66 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.295506E+10 | 2483.66 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.307725E+10 | 2483.66 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.290340E+10 | 2483.66 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.296499E+10 | 2483.66 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.286713E+10 | 2483.66 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.295506E+10 | 2483.66 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.353568E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.269775E+10 | 2483.66 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.307725E+10 | 2483.66 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.296499E+10 | 2483.66 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.269775E+10 | 2483.66 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.307725E+10 | 2483.66 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.290340E+10 | 2483.66 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.302112E+10 | 2483.66 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.296946E+10 | 2483.66 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.295506E+10 | 2483.66 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.307725E+10 | 2483.66 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.290340E+10 | 2483.66 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.296499E+10 | 2483.66 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.286713E+10 | 2483.66 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.295506E+10 | 2483.66 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.353568E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.269775E+10 | 2483.66 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.307725E+10 | 2483.66 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.180413E+09 | 151.13 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.164152E+09 | 151.13 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.187244E+09 | 151.13 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.176665E+09 | 151.13 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.183829E+09 | 151.13 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.180685E+09 | 151.13 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.179809E+09 | 151.13 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.187244E+09 | 151.13 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.176665E+09 | 151.13 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.180413E+09 | 151.13 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.174459E+09 | 151.13 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.179809E+09 | 151.13 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.215139E+10 | ||||
Minimum of Months | 0.164152E+09 | 151.13 | 0.00 | 0.00 | |
Maximum of Months | 0.187244E+09 | 151.13 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.368607E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.703400E+10 |
February | 0.479114E+10 | 0.335384E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.749188E+10 |
March | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2031423.52 | 0.449623E+10 |
April | 0.518069E+10 | 0.360950E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353834E+10 |
May | 0.536353E+10 | 0.375586E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2072268.96 | 0.202194E+10 |
June | 0.528933E+10 | 0.369163E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55340145.37 | 0.127873E+10 |
July | 0.525489E+10 | 0.367372E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140252E+09 | 0.625801E+09 |
August | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89948897.31 | 0.818786E+09 |
September | 0.518069E+10 | 0.360950E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7263366.87 | 0.132125E+10 |
October | 0.524694E+10 | 0.368607E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.293767E+10 |
November | 0.504819E+10 | 0.356442E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402986E+10 |
December | 0.525489E+10 | 0.367372E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.737211E+10 |
Annual Sum or Average | 0.628175E+11 | 0.439556E+11 | 0.499918E+11 | 0.296909E+09 | 0.429666E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.335384E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.625801E+09 |
Maximum of Months | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140252E+09 | 0.749188E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.314662E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.617481E+10 |
February | 0.201852E+11 | 0.286301E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.652609E+10 |
March | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1663203.63 | 0.404222E+10 |
April | 0.218263E+11 | 0.308125E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.332200E+10 |
May | 0.225967E+11 | 0.320619E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1696576.43 | 0.192788E+10 |
June | 0.222841E+11 | 0.315136E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45333218.66 | 0.111979E+10 |
July | 0.221389E+11 | 0.313608E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114707E+09 | 0.517075E+09 |
August | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 73650405.88 | 0.672655E+09 |
September | 0.218263E+11 | 0.308125E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5920919.49 | 0.116345E+10 |
October | 0.221054E+11 | 0.314662E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.269427E+10 |
November | 0.212681E+11 | 0.304277E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366060E+10 |
December | 0.221389E+11 | 0.313608E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.649508E+10 |
Annual Sum or Average | 0.264651E+12 | 0.375227E+12 | 0.842987E+11 | 0.242971E+09 | 0.383159E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.286301E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.517075E+09 |
Maximum of Months | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114707E+09 | 0.652609E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.296499E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308549E+10 |
February | 0.190200E+10 | 0.269775E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.328089E+10 |
March | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 880450.16 | 0.204447E+10 |
April | 0.205665E+10 | 0.290340E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162923E+10 |
May | 0.212923E+10 | 0.302112E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 898237.45 | 0.930324E+09 |
June | 0.209978E+10 | 0.296946E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23989497.69 | 0.571128E+09 |
July | 0.208610E+10 | 0.295506E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60711619.80 | 0.273433E+09 |
August | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38956854.58 | 0.356307E+09 |
September | 0.205665E+10 | 0.290340E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3122960.44 | 0.597409E+09 |
October | 0.208295E+10 | 0.296499E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137755E+10 |
November | 0.200405E+10 | 0.286713E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185558E+10 |
December | 0.208610E+10 | 0.295506E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323230E+10 |
Annual Sum or Average | 0.249375E+11 | 0.353568E+11 | 0.529224E+11 | 0.128560E+09 | 0.192341E+11 | ||||
Minimum of Months | 0.190200E+10 | 0.269775E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273433E+09 |
Maximum of Months | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60711619.80 | 0.328089E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.296499E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304952E+10 |
February | 0.190200E+10 | 0.269775E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324854E+10 |
March | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 880612.22 | 0.197414E+10 |
April | 0.205665E+10 | 0.290340E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154320E+10 |
May | 0.212923E+10 | 0.302112E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 898123.21 | 0.867023E+09 |
June | 0.209978E+10 | 0.296946E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23989539.84 | 0.545801E+09 |
July | 0.208610E+10 | 0.295506E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60779744.04 | 0.268806E+09 |
August | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 38992333.19 | 0.352218E+09 |
September | 0.205665E+10 | 0.290340E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3129404.66 | 0.574482E+09 |
October | 0.208295E+10 | 0.296499E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129903E+10 |
November | 0.200405E+10 | 0.286713E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176225E+10 |
December | 0.208610E+10 | 0.295506E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318625E+10 |
Annual Sum or Average | 0.249375E+11 | 0.353568E+11 | 0.794328E+10 | 0.128670E+09 | 0.186713E+11 | ||||
Minimum of Months | 0.190200E+10 | 0.269775E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268806E+09 |
Maximum of Months | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60779744.04 | 0.324854E+10 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.180413E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.216820E+11 |
February | 0.00 | 0.164152E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202599E+11 |
March | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151501E+11 |
April | 0.00 | 0.176665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.940831E+10 |
May | 0.00 | 0.183829E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139297.32 | 0.431360E+10 |
June | 0.00 | 0.180685E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9977086.86 | 0.157759E+10 |
July | 0.00 | 0.179809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20881084.19 | 0.377681E+09 |
August | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6747802.90 | 0.740158E+09 |
September | 0.00 | 0.176665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239355E+10 |
October | 0.00 | 0.180413E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.828836E+10 |
November | 0.00 | 0.174459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118439E+11 |
December | 0.00 | 0.179809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208523E+11 |
Annual Sum or Average | 0.00 | 0.215139E+10 | 37745271.27 | 0.116887E+12 | |||||
Minimum of Months | 0.00 | 0.164152E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.377681E+09 |
Maximum of Months | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20881084.19 | 0.216820E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 3087.68 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 16146.25 | 12-JAN-06:00 |
February | 5888.82 | 01-FEB-15:09 | 3087.68 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 16479.79 | 13-FEB-05:50 |
March | 5888.82 | 01-MAR-15:09 | 3087.68 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 130.14 | 15-MAR-14:00 | 9238.91 | 02-MAR-05:20 |
April | 5888.82 | 01-APR-10:09 | 3087.68 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 9092.42 | 16-APR-07:00 |
May | 5888.82 | 01-MAY-14:09 | 3087.68 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 197.94 | 14-MAY-15:00 | 3764.48 | 05-MAY-20:05 |
June | 5888.82 | 01-JUN-14:09 | 3087.68 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 565.47 | 12-JUN-13:00 | 3903.76 | 13-JUN-03:00 |
July | 5888.82 | 01-JUL-10:09 | 3087.68 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1662.25 | 21-JUL-03:00 | 2727.47 | 06-JUL-02:00 |
August | 5888.82 | 01-AUG-14:09 | 3087.68 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 698.67 | 13-AUG-18:03 | 2208.77 | 30-AUG-20:10 |
September | 5888.82 | 01-SEP-14:09 | 3087.68 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 255.97 | 16-SEP-13:00 | 3362.74 | 29-SEP-04:00 |
October | 5888.82 | 02-OCT-14:09 | 3087.68 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 4317.14 | 30-OCT-05:00 |
November | 5888.82 | 01-NOV-14:09 | 3087.68 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 8173.34 | 17-NOV-06:00 |
December | 5888.82 | 01-DEC-15:09 | 3087.68 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 12414.36 | 26-DEC-05:30 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2208.77 | |||||
Maximum of Months | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 1662.25 | 16479.79 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 26358.01 | 02-JAN-09:09 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 11746.41 | 12-JAN-01:53 |
February | 24809.68 | 01-FEB-15:09 | 26358.01 | 01-FEB-09:09 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 12210.23 | 13-FEB-05:51 |
March | 24809.68 | 01-MAR-15:09 | 26358.01 | 01-MAR-09:09 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 106.53 | 15-MAR-14:00 | 7288.99 | 02-MAR-01:00 |
April | 24809.68 | 01-APR-10:09 | 26358.01 | 01-APR-09:09 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 7173.67 | 16-APR-01:55 |
May | 24809.68 | 01-MAY-14:09 | 26358.01 | 01-MAY-08:09 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 162.03 | 14-MAY-15:00 | 3615.55 | 05-MAY-21:00 |
June | 24809.68 | 01-JUN-14:09 | 26358.01 | 01-JUN-08:09 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 462.85 | 12-JUN-13:00 | 3656.55 | 13-JUN-03:00 |
July | 24809.68 | 01-JUL-10:09 | 26358.01 | 01-JUL-09:09 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1321.16 | 21-JUL-03:00 | 2484.07 | 06-JUL-02:00 |
August | 24809.68 | 01-AUG-14:09 | 26358.01 | 01-AUG-08:09 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 572.62 | 13-AUG-18:03 | 1882.80 | 30-AUG-20:20 |
September | 24809.68 | 01-SEP-14:09 | 26358.01 | 01-SEP-08:09 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 209.52 | 16-SEP-13:00 | 3348.50 | 29-SEP-04:00 |
October | 24809.68 | 02-OCT-14:09 | 26358.01 | 02-OCT-08:09 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3829.75 | 07-OCT-02:00 |
November | 24809.68 | 01-NOV-14:09 | 26358.01 | 01-NOV-08:09 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 7136.73 | 17-NOV-02:00 |
December | 24809.68 | 01-DEC-15:09 | 26358.01 | 01-DEC-09:09 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 9712.28 | 28-DEC-21:01 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 26358.01 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1882.80 | |||||
Maximum of Months | 24809.68 | 26358.01 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1321.16 | 12210.23 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2483.66 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 6996.65 | 12-JAN-06:00 |
February | 2337.76 | 01-FEB-15:09 | 2483.66 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 7250.41 | 13-FEB-05:59 |
March | 2337.76 | 01-MAR-15:09 | 2483.66 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 56.37 | 15-MAR-14:00 | 4065.30 | 02-MAR-05:10 |
April | 2337.76 | 01-APR-10:09 | 2483.66 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 3940.04 | 16-APR-07:00 |
May | 2337.76 | 01-MAY-14:09 | 2483.66 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 85.78 | 14-MAY-15:00 | 1730.59 | 05-MAY-20:05 |
June | 2337.76 | 01-JUN-14:09 | 2483.66 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 245.04 | 12-JUN-13:00 | 1754.80 | 13-JUN-03:00 |
July | 2337.76 | 01-JUL-10:09 | 2483.66 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 706.15 | 21-JUL-03:00 | 1245.16 | 06-JUL-02:00 |
August | 2337.76 | 01-AUG-14:09 | 2483.66 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 312.52 | 13-AUG-18:10 | 973.15 | 30-AUG-20:20 |
September | 2337.76 | 01-SEP-14:09 | 2483.66 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 110.94 | 16-SEP-13:00 | 1517.88 | 29-SEP-20:05 |
October | 2337.76 | 02-OCT-14:09 | 2483.66 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1870.75 | 30-OCT-05:00 |
November | 2337.76 | 01-NOV-14:09 | 2483.66 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3541.75 | 17-NOV-06:00 |
December | 2337.76 | 01-DEC-15:09 | 2483.66 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5379.52 | 26-DEC-05:20 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 973.15 | |||||
Maximum of Months | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 706.15 | 7250.41 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2483.66 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 6955.01 | 12-JAN-05:50 |
February | 2337.76 | 01-FEB-15:09 | 2483.66 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 7141.67 | 13-FEB-05:50 |
March | 2337.76 | 01-MAR-15:09 | 2483.66 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 56.40 | 15-MAR-14:00 | 4065.30 | 02-MAR-05:10 |
April | 2337.76 | 01-APR-10:09 | 2483.66 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 3940.01 | 16-APR-07:00 |
May | 2337.76 | 01-MAY-14:09 | 2483.66 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 85.78 | 14-MAY-15:00 | 1603.81 | 05-MAY-21:00 |
June | 2337.76 | 01-JUN-14:09 | 2483.66 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 245.04 | 12-JUN-13:00 | 1684.26 | 13-JUN-03:00 |
July | 2337.76 | 01-JUL-10:09 | 2483.66 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 706.14 | 21-JUL-03:00 | 1162.90 | 06-JUL-02:00 |
August | 2337.76 | 01-AUG-14:09 | 2483.66 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 315.48 | 13-AUG-18:10 | 955.62 | 30-AUG-20:10 |
September | 2337.76 | 01-SEP-14:09 | 2483.66 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 110.94 | 16-SEP-13:00 | 1410.31 | 29-SEP-04:00 |
October | 2337.76 | 02-OCT-14:09 | 2483.66 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1870.74 | 30-OCT-05:00 |
November | 2337.76 | 01-NOV-14:09 | 2483.66 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3541.75 | 17-NOV-06:00 |
December | 2337.76 | 01-DEC-15:09 | 2483.66 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5379.50 | 26-DEC-05:30 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 955.62 | |||||
Maximum of Months | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 706.14 | 7141.67 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 151.13 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 41894.69 | 31-JAN-18:00 |
February | 0.00 | 01-FEB-00:10 | 151.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 45284.22 | 06-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 151.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 37095.78 | 06-MAR-18:00 |
April | 0.00 | 01-APR-00:10 | 151.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 29335.96 | 16-APR-11:10 |
May | 0.00 | 01-MAY-00:10 | 151.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.67 | 10-MAY-14:00 | 14272.62 | 18-MAY-11:02 |
June | 0.00 | 01-JUN-00:10 | 151.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 599.71 | 12-JUN-11:03 | 15613.83 | 13-JUN-11:02 |
July | 0.00 | 01-JUL-00:10 | 151.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 645.92 | 15-JUL-13:55 | 3797.16 | 02-JUL-11:10 |
August | 0.00 | 01-AUG-00:10 | 151.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 486.96 | 13-AUG-11:03 | 8047.51 | 31-AUG-11:10 |
September | 0.00 | 01-SEP-00:10 | 151.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 11950.94 | 28-SEP-17:00 |
October | 0.00 | 01-OCT-00:10 | 151.13 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 20118.35 | 24-OCT-11:10 |
November | 0.00 | 01-NOV-00:10 | 151.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 24670.42 | 22-NOV-18:00 |
December | 0.00 | 01-DEC-00:10 | 151.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 42987.60 | 10-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3797.16 | ||||
Maximum of Months | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 645.92 | 45284.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4623.11 | 10-JAN-06:07 | 0.00 | 1200.76 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1618.95 |
February | 7650.04 | 21-FEB-06:06 | 0.00 | 1200.76 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3366.59 |
March | 4538.87 | 15-MAR-14:20 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 107.74 | 0.00 |
April | 3025.23 | 10-APR-16:00 | 5152.71 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1262.70 |
May | 6778.31 | 27-MAY-15:40 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.44 |
June | 13668.12 | 25-JUN-18:20 | 0.00 | 343.08 | 919.71 | 0.00 | 0.00 | 0.00 | 0.00 | 388.90 | 0.00 |
July | 16458.42 | 20-JUL-21:40 | 0.00 | 343.08 | 1226.28 | 0.00 | 0.00 | 0.00 | 0.00 | 219.63 | 0.00 |
August | 15506.33 | 09-AUG-21:00 | 0.00 | 1372.30 | 1226.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.88 |
September | 12484.74 | 17-SEP-07:03 | 0.00 | 514.61 | 1379.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.39 |
October | 5688.25 | 05-OCT-15:00 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.96 |
November | 3097.57 | 28-NOV-15:10 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1273.86 |
December | 3041.64 | 21-DEC-12:40 | 5152.71 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 759.56 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3025.23 | 0.00 | 343.08 | 919.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16458.42 | 5888.82 | 3087.68 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 388.90 | 3366.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 60609.82 | 06-JAN-07:05 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.91 |
February | 59798.79 | 05-FEB-09:05 | 12404.84 | 11714.67 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 686.18 |
March | 59594.18 | 07-MAR-07:05 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 804.59 |
April | 33885.30 | 22-APR-06:03 | 9303.63 | 8786.00 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.46 |
May | 71298.89 | 31-MAY-21:23 | 0.00 | 4393.00 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 660.17 |
June | 78936.96 | 03-JUN-05:02 | 0.00 | 7321.67 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 294.44 |
July | 81692.09 | 12-JUL-05:02 | 0.00 | 7321.67 | 5169.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.59 |
August | 91087.26 | 12-AUG-05:02 | 0.00 | 7321.67 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.47 |
September | 94712.37 | 10-SEP-19:20 | 0.00 | 7321.67 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 65980.93 | 05-OCT-20:33 | 0.00 | 17572.00 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1749.87 |
November | 31581.35 | 15-NOV-07:05 | 6202.42 | 11714.67 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 469.00 |
December | 58863.48 | 10-DEC-09:05 | 12404.84 | 11714.67 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1570.89 |
Annual Sum or Average | |||||||||||
Minimum of Months | 31581.35 | 0.00 | 4393.00 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 94712.37 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1749.87 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5282.29 | 30-JAN-18:33 | 5844.40 | 5519.24 | 11683.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 306.74 |
February | 5499.81 | 14-FEB-06:05 | 0.00 | 1103.85 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1018.04 |
March | 7359.85 | 15-MAR-13:40 | 2045.54 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 49.37 | 0.00 |
April | 5422.26 | 22-APR-13:40 | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.28 |
May | 5945.94 | 27-MAY-16:00 | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.61 |
June | 10703.53 | 27-JUN-20:10 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.14 |
July | 13330.46 | 19-JUL-20:10 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 249.23 | 0.00 |
August | 15493.18 | 10-AUG-20:43 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 139.51 | 0.00 |
September | 12021.62 | 21-SEP-20:10 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.16 |
October | 9328.27 | 11-OCT-12:40 | 2045.54 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.35 |
November | 5748.95 | 01-NOV-12:00 | 2045.54 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 265.94 |
December | 4844.04 | 26-DEC-16:53 | 8182.17 | 9934.63 | 11683.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 890.28 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4844.04 | 0.00 | 1103.85 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15493.18 | 8182.17 | 9934.63 | 11683.55 | 0.00 | 0.00 | 0.00 | 0.00 | 249.23 | 1018.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5329.15 | 29-JAN-08:06 | 0.00 | 965.87 | 511.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.76 |
February | 4039.79 | 25-FEB-06:05 | 0.00 | 827.89 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 844.12 |
March | 4997.81 | 15-MAR-13:40 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 49.40 | 0.00 |
April | 3278.13 | 22-APR-13:40 | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.28 |
May | 3819.95 | 23-MAY-14:50 | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 | 0.00 |
June | 6532.63 | 25-JUN-18:15 | 0.00 | 275.96 | 146.13 | 0.00 | 0.00 | 0.00 | 0.00 | 169.06 | 0.00 |
July | 10499.87 | 19-JUL-20:10 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 251.74 | 0.00 |
August | 12492.00 | 10-AUG-20:43 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 141.51 | 0.00 |
September | 8820.83 | 21-SEP-20:10 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 160.13 |
October | 6992.12 | 11-OCT-14:30 | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.01 |
November | 3310.98 | 01-NOV-12:30 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 284.24 |
December | 4918.79 | 27-DEC-12:02 | 8182.17 | 9934.63 | 1753.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 928.35 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3278.13 | 0.00 | 275.96 | 146.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12492.00 | 8182.17 | 9934.63 | 1753.62 | 0.00 | 0.00 | 0.00 | 0.00 | 251.74 | 928.35 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 177.13 | 17-JAN-05:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.56 |
February | 190.63 | 01-FEB-05:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.74 |
March | 153.93 | 10-MAR-05:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.01 |
April | 160.62 | 17-APR-04:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.82 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.10 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.67 |
August | 0.00 | 01-AUG-00:05 | 0.00 | 16.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.89 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.60 |
October | 124.24 | 30-OCT-04:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.49 |
November | 171.91 | 12-NOV-07:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 140.70 |
December | 129.82 | 14-DEC-05:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.29 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 190.63 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 140.70 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.104401E+12 | 73715.30 | 02-JAN-16:49 | 0.157629E+12 | 213086.06 | 24-JAN-07:10 |
February | 0.941509E+11 | 73715.30 | 01-FEB-17:30 | 0.149874E+12 | 247771.69 | 07-FEB-07:10 |
March | 0.105511E+12 | 88776.98 | 15-MAR-14:09 | 0.825157E+11 | 206431.72 | 07-MAR-07:10 |
April | 0.992925E+11 | 82266.02 | 08-APR-14:30 | 0.322311E+11 | 138073.49 | 17-APR-06:10 |
May | 0.110351E+12 | 93481.60 | 10-MAY-14:00 | 0.115576E+11 | 33372.67 | 01-MAY-06:30 |
June | 0.125516E+12 | 112290.96 | 27-JUN-12:00 | 0.833256E+10 | 16553.86 | 13-JUN-11:00 |
July | 0.141737E+12 | 113660.37 | 15-JUL-14:39 | 0.803224E+10 | 5006.68 | 03-JUL-11:09 |
August | 0.139151E+12 | 108669.52 | 18-AUG-14:39 | 0.813051E+10 | 9714.16 | 31-AUG-11:09 |
September | 0.118930E+12 | 102785.13 | 16-SEP-13:50 | 0.834409E+10 | 15871.41 | 28-SEP-16:00 |
October | 0.105575E+12 | 87326.70 | 12-OCT-14:39 | 0.185714E+11 | 78453.84 | 17-OCT-06:49 |
November | 0.998058E+11 | 82185.65 | 16-NOV-16:00 | 0.418070E+11 | 136875.36 | 24-NOV-07:10 |
December | 0.104390E+12 | 73715.30 | 01-DEC-16:40 | 0.141175E+12 | 234400.14 | 11-DEC-07:10 |
Annual Sum or Average | 0.134881E+13 | 0.668201E+12 | ||||
Minimum of Months | 0.941509E+11 | 73715.30 | 0.803224E+10 | 5006.68 | ||
Maximum of Months | 0.141737E+12 | 113660.37 | 0.157629E+12 | 247771.69 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.412627E+11 | 0.120761E+11 | 0.164409E+11 | 0.00 | 0.346211E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.375436E+11 | 0.100773E+11 | 0.149157E+11 | 0.00 | 0.316143E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.428250E+11 | 0.100114E+11 | 0.168545E+11 | 0.00 | 0.341852E+11 | 0.00 | 0.00 | 0.163449E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.404055E+11 | 0.853104E+10 | 0.160165E+11 | 0.00 | 0.325906E+11 | 0.00 | 0.00 | 0.174887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.420438E+11 | 0.779742E+10 | 0.166477E+11 | 0.00 | 0.323433E+11 | 0.00 | 0.00 | 0.115185E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.413249E+11 | 0.705502E+10 | 0.162772E+11 | 0.00 | 0.304334E+11 | 0.00 | 0.00 | 0.304258E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.411244E+11 | 0.748552E+10 | 0.163871E+11 | 0.00 | 0.307199E+11 | 0.00 | 0.00 | 0.460205E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.428250E+11 | 0.835971E+10 | 0.168545E+11 | 0.00 | 0.312071E+11 | 0.00 | 0.00 | 0.399051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.404055E+11 | 0.918997E+10 | 0.160165E+11 | 0.00 | 0.305142E+11 | 0.00 | 0.00 | 0.228035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.412627E+11 | 0.106836E+11 | 0.164409E+11 | 0.00 | 0.327017E+11 | 0.00 | 0.00 | 0.448616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.399008E+11 | 0.113689E+11 | 0.159174E+11 | 0.00 | 0.321948E+11 | 0.00 | 0.00 | 0.423824E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.411244E+11 | 0.123529E+11 | 0.163871E+11 | 0.00 | 0.345250E+11 | 0.00 | 0.00 | 367549.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.492048E+12 | 0.114989E+12 | 0.195156E+12 | 0.387651E+12 | 0.00 | 0.158967E+12 | |||||||
Minimum of Months | 0.375436E+11 | 0.705502E+10 | 0.149157E+11 | 0.00 | 0.304334E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.428250E+11 | 0.123529E+11 | 0.168545E+11 | 0.00 | 0.346211E+11 | 0.00 | 0.00 | 0.460205E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.148948E+12 | 0.00 | 0.868167E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.141970E+12 | 0.00 | 0.790400E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.737451E+11 | 0.00 | 0.877063E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.239267E+11 | 0.00 | 0.830440E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.316975E+10 | 0.00 | 0.838786E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.360621E+09 | 0.00 | 0.797194E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.803224E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 69705827.29 | 0.00 | 0.806080E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.533847E+09 | 0.00 | 0.781024E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.103908E+11 | 0.00 | 0.818064E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.337166E+11 | 0.00 | 0.809044E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.132616E+12 | 0.00 | 0.855915E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.569447E+12 | 0.987540E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.781024E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.148948E+12 | 0.00 | 0.877063E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 34564.13 | 02-JAN-09:09 | 7321.52 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 21058.62 | 01-JAN-13:20 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 34564.13 | 01-FEB-09:09 | 7321.52 | 01-FEB-00:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 21058.62 | 01-FEB-10:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 34564.13 | 01-MAR-09:09 | 7321.52 | 01-MAR-00:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 21058.62 | 01-MAR-09:30 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 34564.13 | 01-APR-09:09 | 7321.52 | 01-APR-00:10 | 10771.04 | 01-APR-09:09 | 0.00 | 21058.62 | 02-APR-08:30 | 0.00 | 0.00 | 01-APR-00:10 |
May | 34564.13 | 01-MAY-08:09 | 7321.52 | 01-MAY-00:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 21058.62 | 02-MAY-12:39 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 34564.13 | 01-JUN-08:09 | 7321.52 | 01-JUN-00:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 21058.62 | 04-JUN-15:39 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 34564.13 | 01-JUL-09:09 | 7321.52 | 01-JUL-00:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 21058.62 | 02-JUL-11:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 34564.13 | 01-AUG-08:09 | 7321.52 | 01-AUG-00:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 21058.62 | 30-AUG-11:50 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 34564.13 | 01-SEP-08:09 | 7321.52 | 01-SEP-00:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 21058.62 | 02-SEP-16:40 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 34564.13 | 02-OCT-08:09 | 7321.52 | 01-OCT-00:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 21058.62 | 01-OCT-14:20 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 34564.13 | 01-NOV-08:09 | 7321.52 | 01-NOV-00:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 21058.62 | 01-NOV-07:30 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 34564.13 | 01-DEC-09:09 | 7321.52 | 01-DEC-00:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 21058.62 | 02-DEC-09:39 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 34564.13 | 7321.52 | 10771.04 | 0.00 | 21058.62 | 0.00 | 0.00 | |||||
Maximum of Months | 34564.13 | 7321.52 | 10771.04 | 0.00 | 21058.62 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 25189.59 | 15-MAR-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16411.52 | 08-APR-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 29894.20 | 10-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 48703.56 | 27-JUN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 50072.97 | 15-JUL-14:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 45082.13 | 18-AUG-14:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 39197.74 | 16-SEP-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 21693.01 | 11-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 10754.54 | 04-NOV-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 106.64 | 16-DEC-13:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 50072.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 73715.30 | 02-JAN-16:49 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 21058.62 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 73715.30 | 01-FEB-17:30 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 21058.62 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 88776.98 | 15-MAR-14:09 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 25189.59 | 0.00 |
April | 82266.02 | 08-APR-14:30 | 34564.13 | 10771.04 | 0.00 | 0.00 | 21058.62 | 0.00 | 0.00 | 15872.24 | 0.00 |
May | 93481.60 | 10-MAY-14:00 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 29894.20 | 0.00 |
June | 112290.96 | 27-JUN-12:00 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 48703.56 | 0.00 |
July | 113660.37 | 15-JUL-14:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 50072.97 | 0.00 |
August | 108669.52 | 18-AUG-14:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 45082.13 | 0.00 |
September | 102785.13 | 16-SEP-13:50 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 39197.74 | 0.00 |
October | 87326.70 | 12-OCT-14:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 21058.62 | 0.00 | 0.00 | 20932.91 | 0.00 |
November | 82185.65 | 16-NOV-16:00 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 21058.62 | 0.00 | 0.00 | 8470.35 | 0.00 |
December | 73715.30 | 01-DEC-16:40 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 21058.62 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 73715.30 | 34564.13 | 10771.04 | 0.00 | 0.00 | 18252.23 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 113660.37 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 21058.62 | 0.00 | 0.00 | 50072.97 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 208497.74 | 24-JAN-07:10 | 0.00 | 5435.68 | 31-JAN-12:00 | 0.00 |
February | 0.00 | 0.00 | 243182.45 | 07-FEB-07:10 | 0.00 | 5478.41 | 16-FEB-12:00 | 0.00 |
March | 0.00 | 0.00 | 204569.72 | 07-MAR-07:10 | 0.00 | 5445.85 | 01-MAR-12:00 | 0.00 |
April | 0.00 | 0.00 | 133492.45 | 17-APR-06:10 | 0.00 | 5151.00 | 04-APR-11:09 | 0.00 |
May | 0.00 | 0.00 | 28795.79 | 01-MAY-06:30 | 0.00 | 5105.55 | 01-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 11521.83 | 13-JUN-11:00 | 0.00 | 5052.65 | 01-JUN-11:00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 5006.68 | 03-JUL-11:09 | 0.00 |
August | 0.00 | 0.00 | 4729.85 | 31-AUG-11:09 | 0.00 | 4984.84 | 01-AUG-11:30 | 0.00 |
September | 0.00 | 0.00 | 11025.89 | 28-SEP-16:00 | 0.00 | 5006.74 | 29-SEP-11:09 | 0.00 |
October | 0.00 | 0.00 | 73906.26 | 17-OCT-06:40 | 0.00 | 5053.63 | 30-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 132300.22 | 24-NOV-07:10 | 0.00 | 5107.11 | 30-NOV-12:00 | 0.00 |
December | 0.00 | 0.00 | 232538.14 | 11-DEC-07:10 | 0.00 | 5149.07 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4984.84 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 243182.45 | 0.00 | 5478.41 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 17.67 | 18.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 23.50 | 17.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 10.00 | 19.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 4.17 | 20.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.47 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
October | 0.67 | 20.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5.67 | 20.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 14.50 | 18.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 76.17 | 18.45 | 0.00 | 2.00 | 24.47 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 23.50 | 20.41 | 0.00 | 0.00 | 0.83 | 24.48 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.51 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 24.49 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 8.83 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 24.48 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 24.48 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 32.33 | 24.49 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 24.51 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 14.17 | 18.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 19.67 | 17.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6.67 | 19.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 2.67 | 20.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.46 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 24.49 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 24.48 | 0.00 | 0.00 |
October | 0.33 | 20.40 | 0.00 | 0.00 | 0.50 | 24.47 | 0.00 | 0.00 |
November | 3.17 | 20.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 12.17 | 18.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 58.83 | 18.45 | 0.00 | 22.33 | 24.49 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 19.67 | 20.40 | 0.00 | 0.00 | 9.00 | 24.50 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 18.17 | 18.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 23.17 | 16.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 8.17 | 19.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 4.17 | 20.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.50 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.47 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.47 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.46 | 0.00 | 0.00 |
October | 0.83 | 20.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5.00 | 20.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 15.00 | 18.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 74.50 | 18.22 | 0.00 | 2.50 | 24.47 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 23.17 | 20.31 | 0.00 | 0.00 | 1.17 | 24.50 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 18.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 19.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 19.01 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 19.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 408.00 | 21.11 | 408.00 | 21.11 |
February | 376.00 | 21.11 | 376.00 | 21.11 | 376.00 | 21.11 |
March | 420.33 | 21.43 | 291.00 | 21.11 | 291.00 | 21.11 |
April | 405.00 | 22.02 | 108.83 | 21.11 | 108.83 | 21.11 |
May | 373.67 | 23.35 | 5.00 | 21.12 | 5.00 | 21.12 |
June | 105.67 | 23.60 | 150.50 | 23.89 | 10.00 | 23.87 |
July | 28.33 | 23.83 | 332.00 | 23.89 | 17.17 | 23.89 |
August | 30.67 | 23.77 | 264.50 | 23.89 | 7.17 | 23.89 |
September | 136.33 | 23.51 | 104.83 | 23.89 | 1.83 | 23.89 |
October | 388.83 | 22.71 | 24.17 | 21.11 | 24.17 | 21.11 |
November | 399.00 | 21.55 | 168.00 | 21.11 | 168.00 | 21.11 |
December | 415.00 | 21.12 | 392.33 | 21.11 | 392.33 | 21.11 |
Annual Sum or Average | 3492.83 | 21.94 | 2625.17 | 22.01 | 1809.50 | 21.17 |
Minimum of Months | 28.33 | 21.11 | 5.00 | 21.11 | 1.83 | 21.11 |
Maximum of Months | 420.33 | 23.83 | 408.00 | 23.89 | 408.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.12 | 343.17 | 21.11 | 343.17 | 21.11 |
February | 376.00 | 21.12 | 293.50 | 21.11 | 293.50 | 21.11 |
March | 385.67 | 21.42 | 129.83 | 21.22 | 124.50 | 21.11 |
April | 345.50 | 22.34 | 12.83 | 21.11 | 12.83 | 21.11 |
May | 130.00 | 23.34 | 91.33 | 23.89 | 0.17 | 23.89 |
June | 26.33 | 23.51 | 282.83 | 23.89 | 4.00 | 23.89 |
July | 13.33 | 23.87 | 389.33 | 23.89 | 11.83 | 23.89 |
August | 13.00 | 23.79 | 360.17 | 23.89 | 7.00 | 23.89 |
September | 42.00 | 23.31 | 229.50 | 23.89 | 1.67 | 23.89 |
October | 272.00 | 22.65 | 23.50 | 23.89 | 0.00 | 0.00 |
November | 390.17 | 21.78 | 29.67 | 21.11 | 29.67 | 21.11 |
December | 415.00 | 21.14 | 258.00 | 21.11 | 258.00 | 21.11 |
Annual Sum or Average | 2823.00 | 21.73 | 2443.67 | 22.68 | 1086.33 | 21.17 |
Minimum of Months | 13.00 | 21.12 | 12.83 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 415.00 | 23.87 | 389.33 | 23.89 | 343.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.14 | 350.17 | 21.11 | 350.17 | 21.11 |
February | 376.00 | 21.18 | 309.33 | 21.11 | 309.33 | 21.11 |
March | 384.67 | 21.70 | 161.67 | 21.38 | 146.17 | 21.11 |
April | 353.17 | 22.46 | 50.00 | 21.11 | 50.00 | 21.11 |
May | 205.50 | 23.25 | 36.50 | 23.79 | 1.33 | 21.11 |
June | 51.50 | 23.36 | 247.17 | 23.89 | 5.50 | 23.89 |
July | 17.00 | 23.76 | 383.17 | 23.89 | 9.83 | 23.89 |
August | 13.17 | 23.62 | 361.67 | 23.89 | 2.00 | 23.89 |
September | 46.83 | 23.18 | 261.83 | 23.89 | 0.00 | 0.00 |
October | 221.67 | 22.78 | 71.83 | 23.57 | 8.17 | 21.11 |
November | 356.33 | 22.05 | 62.17 | 21.11 | 62.17 | 21.11 |
December | 415.00 | 21.19 | 316.50 | 21.11 | 316.50 | 21.11 |
Annual Sum or Average | 2854.83 | 21.88 | 2612.00 | 22.57 | 1261.17 | 21.15 |
Minimum of Months | 13.17 | 21.14 | 36.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 415.00 | 23.76 | 383.17 | 23.89 | 350.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 386.00 | 21.11 | 386.00 | 21.11 |
February | 376.00 | 21.11 | 349.00 | 21.11 | 349.00 | 21.11 |
March | 398.67 | 21.30 | 201.83 | 21.20 | 195.17 | 21.11 |
April | 387.83 | 21.86 | 78.50 | 21.11 | 78.50 | 21.11 |
May | 289.67 | 22.82 | 22.17 | 23.10 | 6.33 | 21.11 |
June | 91.67 | 23.10 | 205.00 | 23.88 | 11.83 | 23.80 |
July | 39.33 | 23.58 | 371.00 | 23.89 | 23.00 | 23.89 |
August | 39.50 | 23.41 | 338.00 | 23.89 | 14.50 | 23.89 |
September | 83.67 | 22.75 | 222.50 | 23.89 | 2.17 | 23.89 |
October | 293.83 | 22.13 | 57.50 | 23.09 | 16.50 | 21.11 |
November | 387.83 | 21.58 | 112.00 | 21.11 | 112.00 | 21.11 |
December | 415.00 | 21.12 | 365.33 | 21.11 | 365.33 | 21.11 |
Annual Sum or Average | 3217.00 | 21.69 | 2708.83 | 22.34 | 1560.33 | 21.20 |
Minimum of Months | 39.33 | 21.11 | 22.17 | 21.11 | 2.17 | 21.11 |
Maximum of Months | 415.00 | 23.58 | 386.00 | 23.89 | 386.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10993 | 20.65202 | -0.7381 | 16.64768 |
February | 376.00000 | 21.10993 | 20.70261 | -0.7376 | 16.61835 |
March | 422.00000 | 21.43745 | 29.40525 | -0.5399 | 12.95654 |
April | 405.00000 | 22.00915 | 34.67904 | -0.3180 | 8.66821 |
May | 418.00000 | 23.37935 | 39.78061 | -0.9034 | 23.88752 |
June | 408.00000 | 23.80400 | 46.98483 | -0.5682 | 12.41129 |
July | 415.00000 | 23.88346 | 52.92079 | -0.4380 | 9.14130 |
August | 422.00000 | 23.87833 | 49.44920 | -0.4734 | 9.85199 |
September | 405.00000 | 23.74792 | 47.06040 | -0.6155 | 13.74490 |
October | 414.00000 | 22.76967 | 39.19784 | -0.0546 | 6.86333 |
November | 399.00000 | 21.54726 | 33.43452 | -0.4328 | 9.92751 |
December | 415.00000 | 21.11662 | 24.48474 | -0.6870 | 15.17886 |
Annual Sum or Average | 4913.00000 | 22.49447 | 36.67919 | -0.5415 | 12.98337 |
Minimum of Months | 376.00000 | 21.10993 | 20.65202 | -0.9034 | 6.86333 |
Maximum of Months | 422.00000 | 23.88346 | 52.92079 | -0.0546 | 23.88752 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10567 | 19.09644 | -0.6183 | 13.23220 |
February | 376.00000 | 21.10789 | 19.01482 | -0.6104 | 13.01525 |
March | 422.00000 | 21.62719 | 27.26575 | -0.3548 | 9.66767 |
April | 405.00000 | 22.56945 | 32.11705 | -0.0558 | 6.80454 |
May | 418.00000 | 23.71817 | 36.69564 | -0.6054 | 13.55664 |
June | 408.00000 | 23.86421 | 45.13795 | -0.4183 | 8.98895 |
July | 415.00000 | 23.88850 | 52.57994 | -0.3369 | 7.51576 |
August | 422.00000 | 23.88521 | 48.74988 | -0.3774 | 8.14373 |
September | 405.00000 | 23.82905 | 45.48311 | -0.4725 | 10.08786 |
October | 414.00000 | 23.08138 | 36.64364 | 0.11609 | 6.70911 |
November | 399.00000 | 21.83975 | 31.33855 | -0.2620 | 7.73744 |
December | 415.00000 | 21.13035 | 22.81645 | -0.5684 | 12.10305 |
Annual Sum or Average | 4913.00000 | 22.64916 | 34.86287 | -0.3795 | 9.78434 |
Minimum of Months | 376.00000 | 21.10567 | 19.01482 | -0.6183 | 6.70911 |
Maximum of Months | 422.00000 | 23.88850 | 52.57994 | 0.11609 | 13.55664 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.13534 | 18.12456 | -0.6524 | 14.29027 |
February | 376.00000 | 21.17591 | 18.14995 | -0.6409 | 14.12175 |
March | 422.00000 | 21.89297 | 25.89185 | -0.3279 | 9.79306 |
April | 405.00000 | 22.62879 | 30.96552 | -0.0961 | 7.56743 |
May | 418.00000 | 23.54771 | 36.17801 | -0.7297 | 18.05215 |
June | 408.00000 | 23.81286 | 44.14978 | -0.4625 | 10.26178 |
July | 415.00000 | 23.88185 | 50.60850 | -0.3340 | 7.56976 |
August | 422.00000 | 23.87871 | 46.75017 | -0.3526 | 7.90908 |
September | 405.00000 | 23.79703 | 43.45743 | -0.4453 | 10.06870 |
October | 414.00000 | 23.27480 | 34.85817 | 0.16449 | 7.43131 |
November | 399.00000 | 22.23757 | 29.77659 | -0.1955 | 8.05748 |
December | 415.00000 | 21.19311 | 21.93554 | -0.6022 | 13.17302 |
Annual Sum or Average | 4913.00000 | 22.71596 | 33.51875 | -0.3887 | 10.68008 |
Minimum of Months | 376.00000 | 21.13534 | 18.12456 | -0.7297 | 7.43131 |
Maximum of Months | 422.00000 | 23.88185 | 50.60850 | 0.16449 | 18.05215 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10968 | 18.24671 | -0.6949 | 15.41259 |
February | 376.00000 | 21.11225 | 18.26883 | -0.6900 | 15.31241 |
March | 422.00000 | 21.44199 | 26.82971 | -0.4536 | 11.15942 |
April | 405.00000 | 21.94427 | 32.26233 | -0.2664 | 8.47078 |
May | 418.00000 | 23.12750 | 37.85091 | -0.9006 | 24.54022 |
June | 408.00000 | 23.69565 | 46.15118 | -0.5388 | 12.40100 |
July | 415.00000 | 23.85439 | 53.01710 | -0.3721 | 8.24706 |
August | 422.00000 | 23.83804 | 48.65775 | -0.3988 | 8.79153 |
September | 405.00000 | 23.63692 | 45.37807 | -0.5306 | 12.46470 |
October | 414.00000 | 22.62651 | 36.61226 | 0.00424 | 7.35996 |
November | 399.00000 | 21.64535 | 30.92101 | -0.3503 | 9.25353 |
December | 415.00000 | 21.12135 | 22.09908 | -0.6548 | 14.32234 |
Annual Sum or Average | 4913.00000 | 22.44048 | 34.81433 | -0.4865 | 12.30600 |
Minimum of Months | 376.00000 | 21.10968 | 18.24671 | -0.9006 | 7.35996 |
Maximum of Months | 422.00000 | 23.85439 | 53.01710 | 0.00424 | 24.54022 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.413866E+09 | 0.125490E+09 | 27.08 | 0.327201E+09 | 86665334.53 | 0.00 | 0.29 | 15-MAR-14:10 | 0.00 | 01-MAR-00:10 | 8408.62 | 15-MAR-14:10 | 7167.09 | 15-MAR-14:10 | 1747.18 | 14-MAR-14:10 | 2583.63 | 15-MAR-14:10 | 0.00 | 01-MAR-00:10 |
April | 0.182803E+09 | 54916206.10 | 29.00 | 0.167308E+09 | 15495116.17 | 0.00 | 0.17 | 08-APR-14:00 | 0.00 | 01-APR-00:10 | 4754.22 | 08-APR-14:00 | 4051.10 | 08-APR-14:00 | 721.55 | 08-APR-14:20 | 1402.46 | 08-APR-14:00 | 0.00 | 01-APR-00:10 |
May | 0.330082E+10 | 0.975990E+09 | 241.37 | 0.288442E+10 | 0.416401E+09 | 0.00 | 0.35 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 | 10500.43 | 10-MAY-15:00 | 8196.90 | 27-MAY-15:40 | 2329.34 | 10-MAY-15:00 | 3153.97 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.124237E+11 | 0.358198E+10 | 390.00 | 0.974603E+10 | 0.267763E+10 | 0.00 | 0.65 | 27-JUN-13:00 | 0.00 | 01-JUN-00:10 | 21436.88 | 18-JUN-07:05 | 15840.02 | 25-JUN-18:20 | 10454.44 | 18-JUN-07:05 | 6216.32 | 27-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.201787E+11 | 0.579169E+10 | 475.54 | 0.148495E+11 | 0.532915E+10 | 0.00 | 0.94 | 21-JUL-02:55 | 0.00 | 01-JUL-00:10 | 34983.58 | 21-JUL-02:55 | 19613.46 | 19-JUL-21:40 | 15748.94 | 21-JUL-02:55 | 8840.43 | 21-JUL-02:55 | 0.00 | 01-JUL-00:10 |
August | 0.175207E+11 | 0.506659E+10 | 463.03 | 0.137723E+11 | 0.374840E+10 | 0.00 | 0.77 | 14-AUG-21:00 | 0.00 | 01-AUG-00:15 | 25166.28 | 14-AUG-21:00 | 17568.17 | 09-AUG-21:00 | 10605.91 | 14-AUG-05:05 | 6688.71 | 14-AUG-21:00 | 0.00 | 01-AUG-00:05 |
September | 0.954254E+10 | 0.273805E+10 | 354.57 | 0.749513E+10 | 0.204741E+10 | 0.00 | 0.70 | 17-SEP-07:03 | 0.00 | 01-SEP-00:10 | 24046.15 | 17-SEP-07:03 | 15146.82 | 17-SEP-07:03 | 8899.33 | 17-SEP-07:03 | 6083.56 | 17-SEP-07:03 | 0.00 | 01-SEP-00:10 |
October | 0.140793E+10 | 0.416992E+09 | 117.22 | 0.116899E+10 | 0.238947E+09 | 0.00 | 0.27 | 12-OCT-15:00 | 0.00 | 01-OCT-00:10 | 7779.90 | 12-OCT-15:00 | 6467.27 | 11-OCT-15:00 | 1950.27 | 12-OCT-15:00 | 2231.59 | 12-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 35625304.59 | 10812369.50 | 9.17 | 27348709.83 | 8276594.76 | 0.00 | 0.09 | 04-NOV-16:00 | 0.00 | 01-NOV-00:10 | 2435.71 | 04-NOV-16:00 | 1795.41 | 04-NOV-16:00 | 640.30 | 04-NOV-16:00 | 731.72 | 04-NOV-16:00 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.650067E+11 | 0.187625E+11 | 2106.99 | 0.504383E+11 | 0.145684E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.201787E+11 | 0.579169E+10 | 475.54 | 0.148495E+11 | 0.532915E+10 | 0.00 | 0.94 | 0.00 | 34983.58 | 19613.46 | 15748.94 | 8840.43 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.376504E+10 | 0.120575E+10 | 36.91 | 0.308336E+10 | 0.681680E+09 | 0.00 | 0.40 | 15-MAR-14:10 | 0.00 | 01-MAR-00:10 | 55410.91 | 15-MAR-14:10 | 49314.71 | 15-MAR-14:10 | 11990.48 | 14-MAR-13:00 | 17960.56 | 15-MAR-14:10 | 0.00 | 01-MAR-00:10 |
April | 0.406152E+10 | 0.129954E+10 | 79.39 | 0.386831E+10 | 0.193216E+09 | 0.00 | 0.29 | 08-APR-14:00 | 0.00 | 01-APR-00:10 | 39649.35 | 08-APR-14:00 | 34715.16 | 08-APR-13:50 | 5057.12 | 08-APR-14:20 | 12268.06 | 08-APR-14:00 | 0.00 | 01-APR-00:10 |
May | 0.287378E+11 | 0.901290E+10 | 298.61 | 0.259869E+11 | 0.275086E+10 | 0.00 | 0.62 | 31-MAY-21:23 | 0.00 | 01-MAY-00:10 | 85399.02 | 31-MAY-21:23 | 83481.02 | 31-MAY-21:23 | 19477.88 | 17-MAY-14:10 | 25628.79 | 31-MAY-21:23 | 0.00 | 01-MAY-00:10 |
June | 0.733513E+11 | 0.225879E+11 | 409.66 | 0.582864E+11 | 0.150649E+11 | 0.00 | 0.79 | 07-JUN-21:23 | 0.00 | 01-JUN-00:10 | 127863.56 | 07-JUN-21:23 | 97527.18 | 03-JUN-05:02 | 42964.21 | 07-JUN-21:23 | 35054.17 | 27-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.108424E+12 | 0.333234E+11 | 490.34 | 0.798528E+11 | 0.285716E+11 | 0.00 | 0.75 | 15-JUL-21:20 | 0.00 | 01-JUL-00:10 | 117839.83 | 15-JUL-13:55 | 100569.14 | 12-JUL-05:02 | 39958.85 | 15-JUL-13:25 | 35961.22 | 15-JUL-14:20 | 0.00 | 01-JUL-00:10 |
August | 0.917312E+11 | 0.284960E+11 | 458.89 | 0.724521E+11 | 0.192791E+11 | 0.00 | 0.78 | 12-AUG-05:02 | 0.00 | 01-AUG-00:05 | 123364.20 | 12-AUG-05:02 | 110244.59 | 12-AUG-05:02 | 35811.28 | 15-AUG-14:05 | 33155.76 | 12-AUG-05:02 | 0.00 | 01-AUG-00:05 |
September | 0.520105E+11 | 0.160020E+11 | 345.13 | 0.412495E+11 | 0.107610E+11 | 0.00 | 0.75 | 10-SEP-19:20 | 0.00 | 01-SEP-00:10 | 108857.59 | 26-SEP-05:03 | 108511.15 | 10-SEP-19:20 | 28595.10 | 14-SEP-20:20 | 31007.75 | 13-SEP-20:20 | 0.00 | 01-SEP-00:10 |
October | 0.897015E+10 | 0.284057E+10 | 124.37 | 0.768920E+10 | 0.128095E+10 | 0.00 | 0.60 | 05-OCT-20:33 | 0.00 | 01-OCT-00:10 | 81312.01 | 05-OCT-20:33 | 77413.26 | 05-OCT-20:33 | 13104.52 | 12-OCT-20:25 | 24669.56 | 05-OCT-20:33 | 0.00 | 01-OCT-00:10 |
November | 0.623381E+09 | 0.200559E+09 | 12.81 | 0.497708E+09 | 0.125673E+09 | 0.00 | 0.19 | 04-NOV-15:20 | 0.00 | 01-NOV-00:10 | 25788.72 | 04-NOV-15:10 | 20180.19 | 04-NOV-16:00 | 5857.06 | 04-NOV-15:00 | 8184.09 | 04-NOV-15:20 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.371675E+12 | 0.114969E+12 | 2256.10 | 0.292966E+12 | 0.787089E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.108424E+12 | 0.333234E+11 | 490.34 | 0.798528E+11 | 0.285716E+11 | 0.00 | 0.79 | 0.00 | 127863.56 | 110244.59 | 42964.21 | 35961.22 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.738600E+09 | 0.214087E+09 | 53.69 | 0.637468E+09 | 0.101132E+09 | 0.00 | 0.54 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 | 9776.20 | 15-MAR-13:40 | 9047.14 | 15-MAR-13:50 | 1839.30 | 14-MAR-11:50 | 2810.95 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 |
April | 0.111300E+10 | 0.324924E+09 | 137.13 | 0.107782E+10 | 35176233.61 | 0.00 | 0.37 | 08-APR-13:40 | 0.00 | 01-APR-00:10 | 6368.23 | 08-APR-13:40 | 5834.43 | 08-APR-13:30 | 572.84 | 08-APR-14:20 | 1782.41 | 08-APR-13:40 | 0.00 | 01-APR-00:10 |
May | 0.397170E+10 | 0.114936E+10 | 331.32 | 0.365207E+10 | 0.319633E+09 | 0.00 | 0.50 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 | 9134.84 | 10-MAY-15:00 | 7623.90 | 10-MAY-14:50 | 1612.92 | 17-MAY-15:00 | 2645.96 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.957447E+10 | 0.271670E+10 | 430.60 | 0.783596E+10 | 0.173851E+10 | 0.00 | 0.87 | 27-JUN-20:10 | 0.00 | 01-JUN-00:10 | 17963.30 | 27-JUN-20:10 | 12255.68 | 27-JUN-20:10 | 5707.62 | 27-JUN-20:10 | 4503.25 | 27-JUN-20:10 | 0.00 | 01-JUN-00:10 |
July | 0.147658E+11 | 0.417963E+10 | 534.18 | 0.112646E+11 | 0.350127E+10 | 0.00 | 1.00 | 20-JUL-20:10 | 0.00 | 01-JUL-00:10 | 22370.63 | 20-JUL-20:10 | 16034.40 | 19-JUL-20:10 | 8342.68 | 21-JUL-03:25 | 5445.92 | 20-JUL-20:10 | 0.00 | 01-JUL-00:10 |
August | 0.136631E+11 | 0.387946E+10 | 533.13 | 0.112145E+11 | 0.244859E+10 | 0.00 | 1.00 | 10-AUG-20:43 | 0.00 | 01-AUG-00:05 | 21527.41 | 10-AUG-20:43 | 17904.16 | 10-AUG-20:43 | 6228.63 | 13-AUG-18:10 | 5314.41 | 10-AUG-20:43 | 0.00 | 01-AUG-00:05 |
September | 0.928843E+10 | 0.258889E+10 | 426.38 | 0.782306E+10 | 0.146537E+10 | 0.00 | 0.82 | 15-SEP-20:10 | 0.00 | 01-SEP-00:10 | 16366.62 | 15-SEP-20:10 | 12884.94 | 21-SEP-20:10 | 4706.83 | 15-SEP-20:10 | 4145.06 | 15-SEP-20:10 | 0.00 | 01-SEP-00:10 |
October | 0.315737E+10 | 0.898819E+09 | 254.19 | 0.287245E+10 | 0.284918E+09 | 0.00 | 0.60 | 11-OCT-14:30 | 0.00 | 01-OCT-00:10 | 10941.06 | 11-OCT-14:30 | 10215.07 | 11-OCT-14:30 | 1608.41 | 12-OCT-15:00 | 2917.94 | 11-OCT-14:30 | 0.00 | 01-OCT-00:10 |
November | 0.631445E+09 | 0.185320E+09 | 84.39 | 0.584842E+09 | 46602850.86 | 0.00 | 0.29 | 04-NOV-14:50 | 0.00 | 01-NOV-00:10 | 4960.62 | 04-NOV-14:40 | 4476.49 | 16-NOV-12:40 | 884.49 | 04-NOV-14:30 | 1418.00 | 04-NOV-14:40 | 0.00 | 01-NOV-00:10 |
December | 1205307.31 | 367549.83 | 1.33 | 1205307.31 | 0.00 | 0.00 | 0.02 | 16-DEC-13:40 | 0.00 | 01-DEC-00:10 | 350.02 | 16-DEC-13:40 | 350.02 | 16-DEC-13:40 | 0.00 | 01-DEC-00:10 | 106.64 | 16-DEC-13:40 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.569052E+11 | 0.161376E+11 | 2786.35 | 0.469639E+11 | 0.994120E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.147658E+11 | 0.417963E+10 | 534.18 | 0.112646E+11 | 0.350127E+10 | 0.00 | 1.00 | 0.00 | 22370.63 | 17904.16 | 8342.68 | 5445.92 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.337918E+09 | 89156796.22 | 26.25 | 0.278410E+09 | 59507968.87 | 0.00 | 0.48 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 | 7137.16 | 15-MAR-13:50 | 6430.83 | 15-MAR-13:50 | 1475.32 | 14-MAR-13:00 | 1867.30 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 |
April | 0.261860E+09 | 69498149.31 | 56.25 | 0.249857E+09 | 12002858.17 | 0.00 | 0.27 | 08-APR-13:40 | 0.00 | 01-APR-00:10 | 3870.55 | 08-APR-13:40 | 3425.77 | 08-APR-13:40 | 458.19 | 08-APR-14:00 | 994.00 | 08-APR-13:40 | 0.00 | 01-APR-00:10 |
May | 0.144482E+10 | 0.380223E+09 | 193.43 | 0.129083E+10 | 0.153987E+09 | 0.00 | 0.43 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 | 6475.73 | 10-MAY-15:00 | 5158.22 | 10-MAY-14:50 | 1323.56 | 10-MAY-15:00 | 1706.43 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.600398E+10 | 0.153915E+10 | 364.19 | 0.463241E+10 | 0.137157E+10 | 0.00 | 0.74 | 27-JUN-13:00 | 0.00 | 01-JUN-00:10 | 12522.64 | 27-JUN-13:00 | 8577.00 | 27-JUN-13:00 | 4765.02 | 18-JUN-07:05 | 3166.10 | 27-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.107186E+11 | 0.272579E+10 | 477.53 | 0.773499E+10 | 0.298360E+10 | 0.00 | 1.00 | 20-JUL-20:10 | 0.00 | 01-JUL-00:10 | 18840.85 | 20-JUL-20:10 | 12626.90 | 19-JUL-20:10 | 7699.72 | 21-JUL-03:25 | 4075.84 | 20-JUL-20:10 | 0.00 | 01-JUL-00:10 |
August | 0.963872E+10 | 0.246297E+10 | 465.42 | 0.758910E+10 | 0.204962E+10 | 0.00 | 1.00 | 10-AUG-20:43 | 0.00 | 01-AUG-00:05 | 18388.07 | 13-AUG-18:10 | 14357.76 | 10-AUG-20:43 | 6221.97 | 13-AUG-18:10 | 4018.03 | 13-AUG-18:10 | 0.00 | 01-AUG-00:05 |
September | 0.587160E+10 | 0.147458E+10 | 348.98 | 0.471325E+10 | 0.115835E+10 | 0.00 | 0.74 | 21-SEP-20:10 | 0.00 | 01-SEP-00:10 | 12019.07 | 16-SEP-13:30 | 9512.32 | 16-SEP-13:30 | 3380.59 | 15-SEP-11:35 | 2947.17 | 16-SEP-13:30 | 0.00 | 01-SEP-00:10 |
October | 0.128968E+10 | 0.329776E+09 | 129.17 | 0.112873E+10 | 0.160955E+09 | 0.00 | 0.55 | 11-OCT-14:30 | 0.00 | 01-OCT-00:10 | 8396.47 | 11-OCT-14:40 | 7653.79 | 11-OCT-14:30 | 1462.17 | 12-OCT-14:10 | 2027.32 | 11-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.100900E+09 | 27133399.38 | 29.75 | 87547809.58 | 13352128.29 | 0.00 | 0.15 | 04-NOV-14:50 | 0.00 | 01-NOV-00:10 | 2075.92 | 04-NOV-14:50 | 1822.39 | 16-NOV-12:40 | 484.33 | 04-NOV-14:40 | 550.38 | 04-NOV-14:50 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.356681E+11 | 0.909828E+10 | 2090.96 | 0.277051E+11 | 0.796296E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.107186E+11 | 0.272579E+10 | 477.53 | 0.773499E+10 | 0.298360E+10 | 0.00 | 1.00 | 0.00 | 18840.85 | 14357.76 | 7699.72 | 4075.84 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.82 | 4.14 | 9.68 | 2.04 | 80.86 | 0.00 | 0.00 | 744.00 |
February | 21.87 | 6.42 | 15.45 | 8.60 | 75.94 | 0.00 | 0.00 | 672.00 |
March | 33.65 | 17.25 | 16.40 | 29.81 | 55.11 | 0.00 | 0.00 | 744.00 |
April | 45.05 | 24.05 | 21.00 | 50.18 | 41.44 | 0.00 | 0.00 | 720.00 |
May | 57.32 | 35.27 | 22.05 | 74.10 | 30.82 | 4.33 | 0.00 | 744.00 |
June | 66.40 | 41.61 | 24.79 | 95.88 | 20.35 | 0.00 | 0.00 | 720.00 |
July | 61.54 | 37.33 | 24.22 | 94.97 | 14.19 | 0.00 | 0.00 | 744.00 |
August | 52.23 | 28.90 | 23.34 | 78.60 | 17.95 | 0.00 | 0.00 | 744.00 |
September | 39.14 | 21.35 | 17.79 | 52.10 | 29.41 | 1.67 | 0.00 | 720.00 |
October | 24.38 | 10.58 | 13.80 | 23.06 | 43.86 | 0.00 | 0.00 | 744.00 |
November | 14.12 | 4.43 | 9.68 | 7.81 | 53.71 | 0.00 | 0.00 | 720.00 |
December | 12.19 | 2.66 | 9.53 | 1.56 | 78.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.89 | 19.57 | 17.31 | 43.42 | 45.00 | 6.00 | 0.00 | 8760.00 |
Minimum of Months | 12.19 | 2.66 | 9.53 | 1.56 | 14.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.40 | 41.61 | 24.79 | 95.88 | 80.86 | 4.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 968.69 | 565.38 | 403.31 | 690.50 | 1323.18 | 0.00 | 0.00 | 744.00 |
February | 1106.47 | 533.67 | 572.81 | 722.98 | 1291.05 | 0.00 | 0.00 | 672.00 |
March | 1350.75 | 759.22 | 591.53 | 1074.87 | 967.11 | 0.00 | 0.00 | 744.00 |
April | 1118.08 | 446.73 | 671.35 | 778.45 | 750.82 | 0.00 | 0.00 | 720.00 |
May | 978.35 | 284.04 | 694.31 | 656.37 | 517.86 | 0.00 | 0.00 | 744.00 |
June | 950.61 | 201.30 | 749.32 | 761.97 | 333.32 | 0.00 | 0.00 | 720.00 |
July | 970.44 | 235.34 | 735.11 | 916.49 | 219.10 | 0.00 | 0.00 | 744.00 |
August | 1089.49 | 353.12 | 736.37 | 1049.03 | 297.81 | 0.00 | 0.00 | 744.00 |
September | 1267.14 | 617.28 | 649.85 | 1235.24 | 496.34 | 0.00 | 0.00 | 720.00 |
October | 1212.73 | 692.92 | 519.81 | 1108.61 | 767.62 | 0.00 | 0.00 | 744.00 |
November | 868.23 | 490.15 | 378.08 | 722.18 | 936.21 | 0.00 | 0.00 | 720.00 |
December | 809.94 | 419.07 | 390.87 | 540.88 | 1300.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1057.25 | 466.27 | 590.98 | 855.67 | 763.94 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 809.94 | 201.30 | 378.08 | 540.88 | 219.10 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1350.75 | 759.22 | 749.32 | 1235.24 | 1323.18 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 968.69 | 565.38 | 403.31 | 690.19 | 1313.25 | 0.00 | 0.00 | 744.00 |
February | 1106.47 | 533.67 | 572.81 | 723.08 | 1280.88 | 0.00 | 0.00 | 672.00 |
March | 1350.75 | 759.22 | 591.53 | 1082.82 | 940.44 | 0.00 | 0.00 | 744.00 |
April | 1118.08 | 446.73 | 671.35 | 790.96 | 716.65 | 0.00 | 0.00 | 720.00 |
May | 978.35 | 284.04 | 694.31 | 666.16 | 490.05 | 0.00 | 0.00 | 744.00 |
June | 950.61 | 201.30 | 749.32 | 764.01 | 321.24 | 0.00 | 0.00 | 720.00 |
July | 970.44 | 235.34 | 735.11 | 913.77 | 214.43 | 0.00 | 0.00 | 744.00 |
August | 1089.49 | 353.12 | 736.37 | 1046.11 | 292.94 | 0.00 | 0.00 | 744.00 |
September | 1267.14 | 617.28 | 649.85 | 1235.87 | 483.12 | 0.00 | 0.00 | 720.00 |
October | 1212.73 | 692.92 | 519.81 | 1118.15 | 732.68 | 0.00 | 0.00 | 744.00 |
November | 868.23 | 490.15 | 378.08 | 730.11 | 900.20 | 0.00 | 0.00 | 720.00 |
December | 809.94 | 419.07 | 390.87 | 541.51 | 1288.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1057.25 | 466.27 | 590.98 | 859.44 | 745.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 809.94 | 201.30 | 378.08 | 541.51 | 214.43 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1350.75 | 759.22 | 749.32 | 1235.87 | 1313.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 199.32 | 116.34 | 82.99 | 137.20 | 274.41 | 0.00 | 0.00 | 744.00 |
February | 227.67 | 109.81 | 117.86 | 143.11 | 268.19 | 0.00 | 0.00 | 672.00 |
March | 277.94 | 156.22 | 121.72 | 216.77 | 194.70 | 0.00 | 0.00 | 744.00 |
April | 230.06 | 91.92 | 138.14 | 160.14 | 146.51 | 0.00 | 0.00 | 720.00 |
May | 201.31 | 58.44 | 142.86 | 139.21 | 96.13 | 0.00 | 0.00 | 744.00 |
June | 195.60 | 41.42 | 154.18 | 156.79 | 63.31 | 0.00 | 0.00 | 720.00 |
July | 199.68 | 48.42 | 151.26 | 180.32 | 45.54 | 0.00 | 0.00 | 744.00 |
August | 224.18 | 72.66 | 151.52 | 208.53 | 61.56 | 0.00 | 0.00 | 744.00 |
September | 260.73 | 127.02 | 133.72 | 254.37 | 94.82 | 0.00 | 0.00 | 720.00 |
October | 249.54 | 142.58 | 106.96 | 227.95 | 146.98 | 0.00 | 0.00 | 744.00 |
November | 178.65 | 100.86 | 77.80 | 146.68 | 184.68 | 0.00 | 0.00 | 720.00 |
December | 166.66 | 86.23 | 80.43 | 107.43 | 268.71 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 217.54 | 95.94 | 121.60 | 173.39 | 153.20 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 166.66 | 41.42 | 77.80 | 107.43 | 45.54 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 277.94 | 156.22 | 154.18 | 254.37 | 274.41 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37011745.92 | 11094321.87 | 25917424.05 | 5472311.09 | 0.216579E+09 |
February | 52919288.58 | 15540182.77 | 37379105.81 | 20816674.02 | 0.183717E+09 |
March | 90139859.71 | 46211008.97 | 43928850.74 | 79842302.27 | 0.147596E+09 |
April | 0.116771E+09 | 62331444.50 | 54439286.65 | 0.130057E+09 | 0.107405E+09 |
May | 0.153521E+09 | 94468261.67 | 59052597.95 | 0.198461E+09 | 82541415.65 |
June | 0.172104E+09 | 0.107849E+09 | 64254823.17 | 0.248523E+09 | 52755157.39 |
July | 0.164841E+09 | 99982851.66 | 64857843.22 | 0.254361E+09 | 37998840.44 |
August | 0.139899E+09 | 77398224.51 | 62500481.06 | 0.210509E+09 | 48088425.25 |
September | 0.101450E+09 | 55333459.34 | 46116818.44 | 0.135055E+09 | 76232842.21 |
October | 65310773.03 | 28344146.43 | 36966626.60 | 61764688.37 | 0.117467E+09 |
November | 36593218.96 | 11490635.54 | 25102583.42 | 20239087.20 | 0.139223E+09 |
December | 32657837.85 | 7134120.69 | 25523717.16 | 4189104.98 | 0.209525E+09 |
Annual Sum or Average | 0.116322E+10 | 0.617178E+09 | 0.546040E+09 | 0.136929E+10 | 0.141913E+10 |
Minimum of Months | 32657837.85 | 7134120.69 | 25102583.42 | 4189104.98 | 37998840.44 |
Maximum of Months | 0.172104E+09 | 0.107849E+09 | 64857843.22 | 0.254361E+09 | 0.216579E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.259455E+10 | 0.151431E+10 | 0.108023E+10 | 0.184944E+10 | 0.354400E+10 |
February | 0.267678E+10 | 0.129105E+10 | 0.138573E+10 | 0.174904E+10 | 0.312332E+10 |
March | 0.361785E+10 | 0.203349E+10 | 0.158436E+10 | 0.287895E+10 | 0.259032E+10 |
April | 0.289806E+10 | 0.115791E+10 | 0.174015E+10 | 0.201773E+10 | 0.194613E+10 |
May | 0.262040E+10 | 0.760766E+09 | 0.185963E+10 | 0.175803E+10 | 0.138703E+10 |
June | 0.246398E+10 | 0.521758E+09 | 0.194223E+10 | 0.197504E+10 | 0.863953E+09 |
July | 0.259924E+10 | 0.630330E+09 | 0.196891E+10 | 0.245474E+10 | 0.586841E+09 |
August | 0.291809E+10 | 0.945798E+09 | 0.197229E+10 | 0.280972E+10 | 0.797648E+09 |
September | 0.328442E+10 | 0.160000E+10 | 0.168442E+10 | 0.320175E+10 | 0.128651E+10 |
October | 0.324818E+10 | 0.185593E+10 | 0.139225E+10 | 0.296930E+10 | 0.205600E+10 |
November | 0.225045E+10 | 0.127047E+10 | 0.979982E+09 | 0.187189E+10 | 0.242666E+10 |
December | 0.216935E+10 | 0.112245E+10 | 0.104691E+10 | 0.144870E+10 | 0.348329E+10 |
Annual Sum or Average | 0.333413E+11 | 0.147043E+11 | 0.186371E+11 | 0.269843E+11 | 0.240917E+11 |
Minimum of Months | 0.216935E+10 | 0.521758E+09 | 0.979982E+09 | 0.144870E+10 | 0.586841E+09 |
Maximum of Months | 0.361785E+10 | 0.203349E+10 | 0.197229E+10 | 0.320175E+10 | 0.354400E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.259455E+10 | 0.151431E+10 | 0.108023E+10 | 0.184862E+10 | 0.351740E+10 |
February | 0.267678E+10 | 0.129105E+10 | 0.138573E+10 | 0.174928E+10 | 0.309871E+10 |
March | 0.361785E+10 | 0.203349E+10 | 0.158436E+10 | 0.290023E+10 | 0.251887E+10 |
April | 0.289806E+10 | 0.115791E+10 | 0.174015E+10 | 0.205017E+10 | 0.185756E+10 |
May | 0.262040E+10 | 0.760766E+09 | 0.185963E+10 | 0.178424E+10 | 0.131256E+10 |
June | 0.246398E+10 | 0.521758E+09 | 0.194223E+10 | 0.198031E+10 | 0.832657E+09 |
July | 0.259924E+10 | 0.630330E+09 | 0.196891E+10 | 0.244743E+10 | 0.574329E+09 |
August | 0.291809E+10 | 0.945798E+09 | 0.197229E+10 | 0.280190E+10 | 0.784603E+09 |
September | 0.328442E+10 | 0.160000E+10 | 0.168442E+10 | 0.320338E+10 | 0.125226E+10 |
October | 0.324818E+10 | 0.185593E+10 | 0.139225E+10 | 0.299485E+10 | 0.196240E+10 |
November | 0.225045E+10 | 0.127047E+10 | 0.979982E+09 | 0.189245E+10 | 0.233332E+10 |
December | 0.216935E+10 | 0.112245E+10 | 0.104691E+10 | 0.145039E+10 | 0.345017E+10 |
Annual Sum or Average | 0.333413E+11 | 0.147043E+11 | 0.186371E+11 | 0.271032E+11 | 0.234948E+11 |
Minimum of Months | 0.216935E+10 | 0.521758E+09 | 0.979982E+09 | 0.145039E+10 | 0.574329E+09 |
Maximum of Months | 0.361785E+10 | 0.203349E+10 | 0.197229E+10 | 0.320338E+10 | 0.351740E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.533866E+09 | 0.311592E+09 | 0.222274E+09 | 0.367472E+09 | 0.734981E+09 |
February | 0.550786E+09 | 0.265651E+09 | 0.285134E+09 | 0.346219E+09 | 0.648814E+09 |
March | 0.744424E+09 | 0.418419E+09 | 0.326005E+09 | 0.580597E+09 | 0.521473E+09 |
April | 0.596317E+09 | 0.238257E+09 | 0.358060E+09 | 0.415070E+09 | 0.379751E+09 |
May | 0.539185E+09 | 0.156539E+09 | 0.382647E+09 | 0.372855E+09 | 0.257462E+09 |
June | 0.507001E+09 | 0.107359E+09 | 0.399641E+09 | 0.406404E+09 | 0.164108E+09 |
July | 0.534831E+09 | 0.129700E+09 | 0.405131E+09 | 0.482961E+09 | 0.121973E+09 |
August | 0.600439E+09 | 0.194612E+09 | 0.405827E+09 | 0.558529E+09 | 0.164893E+09 |
September | 0.675818E+09 | 0.329223E+09 | 0.346595E+09 | 0.659326E+09 | 0.245764E+09 |
October | 0.668360E+09 | 0.381884E+09 | 0.286476E+09 | 0.610537E+09 | 0.393677E+09 |
November | 0.463063E+09 | 0.261418E+09 | 0.201645E+09 | 0.380193E+09 | 0.478696E+09 |
December | 0.446376E+09 | 0.230960E+09 | 0.215416E+09 | 0.287744E+09 | 0.719701E+09 |
Annual Sum or Average | 0.686047E+10 | 0.302561E+10 | 0.383485E+10 | 0.546791E+10 | 0.483129E+10 |
Minimum of Months | 0.446376E+09 | 0.107359E+09 | 0.201645E+09 | 0.287744E+09 | 0.121973E+09 |
Maximum of Months | 0.744424E+09 | 0.418419E+09 | 0.405827E+09 | 0.659326E+09 | 0.734981E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 16.35 | 646.89 | 110.55 | 33.14 | 77.41 | 0.00 | 0.00 |
February | 68.84 | 607.53 | 175.00 | 51.39 | 123.61 | 0.00 | 0.00 |
March | 238.48 | 440.85 | 269.23 | 138.03 | 131.21 | 0.00 | 0.00 |
April | 401.41 | 331.50 | 360.40 | 192.38 | 168.02 | 0.00 | 0.00 |
May | 592.78 | 246.54 | 458.54 | 282.16 | 176.38 | 0.00 | 0.00 |
June | 767.05 | 162.82 | 531.19 | 332.87 | 198.32 | 0.00 | 0.00 |
July | 759.74 | 113.50 | 492.36 | 298.63 | 193.72 | 0.00 | 0.00 |
August | 628.76 | 143.63 | 417.86 | 231.18 | 186.68 | 0.00 | 0.00 |
September | 416.84 | 235.29 | 313.12 | 170.78 | 142.34 | 0.00 | 0.00 |
October | 184.48 | 350.86 | 195.07 | 84.66 | 110.41 | 0.00 | 0.00 |
November | 62.47 | 429.70 | 112.94 | 35.46 | 77.48 | 0.00 | 0.00 |
December | 12.51 | 625.82 | 97.54 | 21.31 | 76.24 | 0.00 | 0.00 |
Annual Sum or Average | 347.36 | 360.00 | 295.08 | 156.56 | 138.52 | 0.00 | 0.00 |
Minimum of Months | 12.51 | 113.50 | 97.54 | 21.31 | 76.24 | 0.00 | 0.00 |
Maximum of Months | 767.05 | 646.89 | 531.19 | 332.87 | 198.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 690.50 | 1323.18 | 968.69 | 565.38 | 403.31 | 0.00 | 0.00 |
February | 722.98 | 1291.05 | 1106.47 | 533.67 | 572.81 | 0.00 | 0.00 |
March | 1074.87 | 967.11 | 1350.75 | 759.22 | 591.53 | 0.00 | 0.00 |
April | 778.45 | 750.82 | 1118.08 | 446.73 | 671.35 | 0.00 | 0.00 |
May | 656.37 | 517.86 | 978.35 | 284.04 | 694.31 | 0.00 | 0.00 |
June | 761.97 | 333.32 | 950.61 | 201.30 | 749.32 | 0.00 | 0.00 |
July | 916.49 | 219.10 | 970.44 | 235.34 | 735.11 | 0.00 | 0.00 |
August | 1049.03 | 297.81 | 1089.49 | 353.12 | 736.37 | 0.00 | 0.00 |
September | 1235.24 | 496.34 | 1267.14 | 617.28 | 649.85 | 0.00 | 0.00 |
October | 1108.61 | 767.62 | 1212.73 | 692.92 | 519.81 | 0.00 | 0.00 |
November | 722.18 | 936.21 | 868.23 | 490.15 | 378.08 | 0.00 | 0.00 |
December | 540.88 | 1300.51 | 809.94 | 419.07 | 390.87 | 0.00 | 0.00 |
Annual Sum or Average | 855.67 | 763.94 | 1057.25 | 466.27 | 590.98 | 0.00 | 0.00 |
Minimum of Months | 540.88 | 219.10 | 809.94 | 201.30 | 378.08 | 0.00 | 0.00 |
Maximum of Months | 1235.24 | 1323.18 | 1350.75 | 759.22 | 749.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 690.19 | 1313.25 | 968.69 | 565.38 | 403.31 | 0.00 | 0.00 |
February | 723.08 | 1280.88 | 1106.47 | 533.67 | 572.81 | 0.00 | 0.00 |
March | 1082.82 | 940.44 | 1350.75 | 759.22 | 591.53 | 0.00 | 0.00 |
April | 790.96 | 716.65 | 1118.08 | 446.73 | 671.35 | 0.00 | 0.00 |
May | 666.16 | 490.05 | 978.35 | 284.04 | 694.31 | 0.00 | 0.00 |
June | 764.01 | 321.24 | 950.61 | 201.30 | 749.32 | 0.00 | 0.00 |
July | 913.77 | 214.43 | 970.44 | 235.34 | 735.11 | 0.00 | 0.00 |
August | 1046.11 | 292.94 | 1089.49 | 353.12 | 736.37 | 0.00 | 0.00 |
September | 1235.87 | 483.12 | 1267.14 | 617.28 | 649.85 | 0.00 | 0.00 |
October | 1118.15 | 732.68 | 1212.73 | 692.92 | 519.81 | 0.00 | 0.00 |
November | 730.11 | 900.20 | 868.23 | 490.15 | 378.08 | 0.00 | 0.00 |
December | 541.51 | 1288.15 | 809.94 | 419.07 | 390.87 | 0.00 | 0.00 |
Annual Sum or Average | 859.44 | 745.02 | 1057.25 | 466.27 | 590.98 | 0.00 | 0.00 |
Minimum of Months | 541.51 | 214.43 | 809.94 | 201.30 | 378.08 | 0.00 | 0.00 |
Maximum of Months | 1235.87 | 1313.25 | 1350.75 | 759.22 | 749.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 137.20 | 274.41 | 199.32 | 116.34 | 82.99 | 0.00 | 0.00 |
February | 143.11 | 268.19 | 227.67 | 109.81 | 117.86 | 0.00 | 0.00 |
March | 216.77 | 194.70 | 277.94 | 156.22 | 121.72 | 0.00 | 0.00 |
April | 160.14 | 146.51 | 230.06 | 91.92 | 138.14 | 0.00 | 0.00 |
May | 139.21 | 96.13 | 201.31 | 58.44 | 142.86 | 0.00 | 0.00 |
June | 156.79 | 63.31 | 195.60 | 41.42 | 154.18 | 0.00 | 0.00 |
July | 180.32 | 45.54 | 199.68 | 48.42 | 151.26 | 0.00 | 0.00 |
August | 208.53 | 61.56 | 224.18 | 72.66 | 151.52 | 0.00 | 0.00 |
September | 254.37 | 94.82 | 260.73 | 127.02 | 133.72 | 0.00 | 0.00 |
October | 227.95 | 146.98 | 249.54 | 142.58 | 106.96 | 0.00 | 0.00 |
November | 146.68 | 184.68 | 178.65 | 100.86 | 77.80 | 0.00 | 0.00 |
December | 107.43 | 268.71 | 166.66 | 86.23 | 80.43 | 0.00 | 0.00 |
Annual Sum or Average | 173.39 | 153.20 | 217.54 | 95.94 | 121.60 | 0.00 | 0.00 |
Minimum of Months | 107.43 | 45.54 | 166.66 | 41.42 | 77.80 | 0.00 | 0.00 |
Maximum of Months | 254.37 | 274.41 | 277.94 | 156.22 | 154.18 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 43778488.74 | 0.173264E+10 | 0.296094E+09 | 88754574.93 | 0.207339E+09 | 0.00 | 0.00 |
February | 0.166533E+09 | 0.146974E+10 | 0.423354E+09 | 0.124321E+09 | 0.299033E+09 | 0.00 | 0.00 |
March | 0.638738E+09 | 0.118077E+10 | 0.721119E+09 | 0.369688E+09 | 0.351431E+09 | 0.00 | 0.00 |
April | 0.104046E+10 | 0.859240E+09 | 0.934166E+09 | 0.498652E+09 | 0.435514E+09 | 0.00 | 0.00 |
May | 0.158769E+10 | 0.660331E+09 | 0.122817E+10 | 0.755746E+09 | 0.472421E+09 | 0.00 | 0.00 |
June | 0.198819E+10 | 0.422041E+09 | 0.137683E+10 | 0.862793E+09 | 0.514039E+09 | 0.00 | 0.00 |
July | 0.203489E+10 | 0.303991E+09 | 0.131873E+10 | 0.799863E+09 | 0.518863E+09 | 0.00 | 0.00 |
August | 0.168407E+10 | 0.384707E+09 | 0.111919E+10 | 0.619186E+09 | 0.500004E+09 | 0.00 | 0.00 |
September | 0.108044E+10 | 0.609863E+09 | 0.811602E+09 | 0.442668E+09 | 0.368935E+09 | 0.00 | 0.00 |
October | 0.494118E+09 | 0.939737E+09 | 0.522486E+09 | 0.226753E+09 | 0.295733E+09 | 0.00 | 0.00 |
November | 0.161913E+09 | 0.111379E+10 | 0.292746E+09 | 91925084.30 | 0.200821E+09 | 0.00 | 0.00 |
December | 33512839.86 | 0.167620E+10 | 0.261263E+09 | 57072965.50 | 0.204190E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.109543E+11 | 0.113530E+11 | 0.930574E+10 | 0.493742E+10 | 0.436832E+10 | 0.00 | 0.00 |
Minimum of Months | 33512839.86 | 0.303991E+09 | 0.261263E+09 | 57072965.50 | 0.200821E+09 | 0.00 | 0.00 |
Maximum of Months | 0.203489E+10 | 0.173264E+10 | 0.137683E+10 | 0.862793E+09 | 0.518863E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.184944E+10 | 0.354400E+10 | 0.259455E+10 | 0.151431E+10 | 0.108023E+10 | 0.00 | 0.00 |
February | 0.174904E+10 | 0.312332E+10 | 0.267678E+10 | 0.129105E+10 | 0.138573E+10 | 0.00 | 0.00 |
March | 0.287895E+10 | 0.259032E+10 | 0.361785E+10 | 0.203349E+10 | 0.158436E+10 | 0.00 | 0.00 |
April | 0.201773E+10 | 0.194613E+10 | 0.289806E+10 | 0.115791E+10 | 0.174015E+10 | 0.00 | 0.00 |
May | 0.175803E+10 | 0.138703E+10 | 0.262040E+10 | 0.760766E+09 | 0.185963E+10 | 0.00 | 0.00 |
June | 0.197504E+10 | 0.863953E+09 | 0.246398E+10 | 0.521758E+09 | 0.194223E+10 | 0.00 | 0.00 |
July | 0.245474E+10 | 0.586841E+09 | 0.259924E+10 | 0.630330E+09 | 0.196891E+10 | 0.00 | 0.00 |
August | 0.280972E+10 | 0.797648E+09 | 0.291809E+10 | 0.945798E+09 | 0.197229E+10 | 0.00 | 0.00 |
September | 0.320175E+10 | 0.128651E+10 | 0.328442E+10 | 0.160000E+10 | 0.168442E+10 | 0.00 | 0.00 |
October | 0.296930E+10 | 0.205600E+10 | 0.324818E+10 | 0.185593E+10 | 0.139225E+10 | 0.00 | 0.00 |
November | 0.187189E+10 | 0.242666E+10 | 0.225045E+10 | 0.127047E+10 | 0.979982E+09 | 0.00 | 0.00 |
December | 0.144870E+10 | 0.348329E+10 | 0.216935E+10 | 0.112245E+10 | 0.104691E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.269843E+11 | 0.240917E+11 | 0.333413E+11 | 0.147043E+11 | 0.186371E+11 | 0.00 | 0.00 |
Minimum of Months | 0.144870E+10 | 0.586841E+09 | 0.216935E+10 | 0.521758E+09 | 0.979982E+09 | 0.00 | 0.00 |
Maximum of Months | 0.320175E+10 | 0.354400E+10 | 0.361785E+10 | 0.203349E+10 | 0.197229E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.184862E+10 | 0.351740E+10 | 0.259455E+10 | 0.151431E+10 | 0.108023E+10 | 0.00 | 0.00 |
February | 0.174928E+10 | 0.309871E+10 | 0.267678E+10 | 0.129105E+10 | 0.138573E+10 | 0.00 | 0.00 |
March | 0.290023E+10 | 0.251887E+10 | 0.361785E+10 | 0.203349E+10 | 0.158436E+10 | 0.00 | 0.00 |
April | 0.205017E+10 | 0.185756E+10 | 0.289806E+10 | 0.115791E+10 | 0.174015E+10 | 0.00 | 0.00 |
May | 0.178424E+10 | 0.131256E+10 | 0.262040E+10 | 0.760766E+09 | 0.185963E+10 | 0.00 | 0.00 |
June | 0.198031E+10 | 0.832657E+09 | 0.246398E+10 | 0.521758E+09 | 0.194223E+10 | 0.00 | 0.00 |
July | 0.244743E+10 | 0.574329E+09 | 0.259924E+10 | 0.630330E+09 | 0.196891E+10 | 0.00 | 0.00 |
August | 0.280190E+10 | 0.784603E+09 | 0.291809E+10 | 0.945798E+09 | 0.197229E+10 | 0.00 | 0.00 |
September | 0.320338E+10 | 0.125226E+10 | 0.328442E+10 | 0.160000E+10 | 0.168442E+10 | 0.00 | 0.00 |
October | 0.299485E+10 | 0.196240E+10 | 0.324818E+10 | 0.185593E+10 | 0.139225E+10 | 0.00 | 0.00 |
November | 0.189245E+10 | 0.233332E+10 | 0.225045E+10 | 0.127047E+10 | 0.979982E+09 | 0.00 | 0.00 |
December | 0.145039E+10 | 0.345017E+10 | 0.216935E+10 | 0.112245E+10 | 0.104691E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.271032E+11 | 0.234948E+11 | 0.333413E+11 | 0.147043E+11 | 0.186371E+11 | 0.00 | 0.00 |
Minimum of Months | 0.145039E+10 | 0.574329E+09 | 0.216935E+10 | 0.521758E+09 | 0.979982E+09 | 0.00 | 0.00 |
Maximum of Months | 0.320338E+10 | 0.351740E+10 | 0.361785E+10 | 0.203349E+10 | 0.197229E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.367472E+09 | 0.734981E+09 | 0.533866E+09 | 0.311592E+09 | 0.222274E+09 | 0.00 | 0.00 |
February | 0.346219E+09 | 0.648814E+09 | 0.550786E+09 | 0.265651E+09 | 0.285134E+09 | 0.00 | 0.00 |
March | 0.580597E+09 | 0.521473E+09 | 0.744424E+09 | 0.418419E+09 | 0.326005E+09 | 0.00 | 0.00 |
April | 0.415070E+09 | 0.379751E+09 | 0.596317E+09 | 0.238257E+09 | 0.358060E+09 | 0.00 | 0.00 |
May | 0.372855E+09 | 0.257462E+09 | 0.539185E+09 | 0.156539E+09 | 0.382647E+09 | 0.00 | 0.00 |
June | 0.406404E+09 | 0.164108E+09 | 0.507001E+09 | 0.107359E+09 | 0.399641E+09 | 0.00 | 0.00 |
July | 0.482961E+09 | 0.121973E+09 | 0.534831E+09 | 0.129700E+09 | 0.405131E+09 | 0.00 | 0.00 |
August | 0.558529E+09 | 0.164893E+09 | 0.600439E+09 | 0.194612E+09 | 0.405827E+09 | 0.00 | 0.00 |
September | 0.659326E+09 | 0.245764E+09 | 0.675818E+09 | 0.329223E+09 | 0.346595E+09 | 0.00 | 0.00 |
October | 0.610537E+09 | 0.393677E+09 | 0.668360E+09 | 0.381884E+09 | 0.286476E+09 | 0.00 | 0.00 |
November | 0.380193E+09 | 0.478696E+09 | 0.463063E+09 | 0.261418E+09 | 0.201645E+09 | 0.00 | 0.00 |
December | 0.287744E+09 | 0.719701E+09 | 0.446376E+09 | 0.230960E+09 | 0.215416E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.546791E+10 | 0.483129E+10 | 0.686047E+10 | 0.302561E+10 | 0.383485E+10 | 0.00 | 0.00 |
Minimum of Months | 0.287744E+09 | 0.121973E+09 | 0.446376E+09 | 0.107359E+09 | 0.201645E+09 | 0.00 | 0.00 |
Maximum of Months | 0.659326E+09 | 0.734981E+09 | 0.744424E+09 | 0.418419E+09 | 0.405827E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -3.4 | -4.9 | -8.7 | 5.96 | -14.4 | 41.15 | 62.17 | 0.00 |
February | -4.2 | -5.3 | -8.1 | 6.66 | -15.1 | 65.72 | 71.39 | 0.00 |
March | 2.67 | 0.73 | -2.8 | 5.20 | -8.9 | 69.76 | 141.76 | 0.00 |
April | 7.47 | 4.95 | 1.92 | 5.29 | -2.7 | 89.32 | 159.79 | 0.00 |
May | 13.73 | 9.65 | 5.81 | 4.79 | 3.34 | 93.75 | 203.34 | 0.03 |
June | 18.63 | 14.46 | 11.49 | 5.10 | 8.69 | 105.42 | 236.95 | 0.00 |
July | 22.03 | 18.19 | 16.11 | 4.43 | 13.38 | 102.98 | 214.28 | 0.00 |
August | 20.69 | 16.38 | 13.72 | 4.23 | 11.88 | 99.24 | 178.64 | 0.00 |
September | 16.55 | 13.41 | 11.22 | 4.10 | 7.07 | 75.66 | 154.97 | 0.03 |
October | 9.73 | 7.35 | 4.97 | 4.79 | 0.12 | 58.70 | 104.01 | 0.00 |
November | 6.03 | 3.71 | 0.77 | 5.87 | -3.2 | 41.19 | 58.47 | 0.00 |
December | -2.2 | -3.2 | -5.3 | 6.59 | -12.0 | 40.52 | 44.30 | 0.00 |
Annual Sum or Average | 9.05 | 6.35 | 3.49 | 5.24 | -0.9 | 73.64 | 136.19 | 0.01 |
Minimum of Months | -4.2 | -5.3 | -8.7 | 4.10 | -15.1 | 40.52 | 44.30 | 0.00 |
Maximum of Months | 22.03 | 18.19 | 16.11 | 6.66 | 13.38 | 105.42 | 236.95 | 0.03 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.70 | 11-JAN-15:00 | 10.13 | 8.90 | 13.40 | 7.15 | 65.50 | 1.00 |
February | 12.80 | 22-FEB-17:00 | 6.16 | -2.2 | 14.90 | 3.48 | 0.00 | 0.00 |
March | 26.10 | 15-MAR-13:00 | 16.04 | 9.40 | 6.70 | 14.65 | 249.50 | 400.00 |
April | 21.10 | 08-APR-12:00 | 13.42 | 7.80 | 8.20 | 11.46 | 330.00 | 283.50 |
May | 26.10 | 10-MAY-13:00 | 17.82 | 13.30 | 5.20 | 13.35 | 258.50 | 457.00 |
June | 30.60 | 12-JUN-13:00 | 20.22 | 15.00 | 8.20 | 17.93 | 252.00 | 572.00 |
July | 31.70 | 21-JUL-13:00 | 21.71 | 17.20 | 5.20 | 22.47 | 330.00 | 231.00 |
August | 30.60 | 10-AUG-13:00 | 20.23 | 15.00 | 5.70 | 19.70 | 220.50 | 635.00 |
September | 27.20 | 16-SEP-13:09 | 19.51 | 15.68 | 8.80 | 17.30 | 207.00 | 564.67 |
October | 22.20 | 11-OCT-12:00 | 14.12 | 8.30 | 6.20 | 6.95 | 121.00 | 665.00 |
November | 19.40 | 05-NOV-13:00 | 13.84 | 10.00 | 12.40 | 14.84 | 133.00 | 3.50 |
December | 15.00 | 01-DEC-10:00 | 12.40 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.70 | 6.16 | -2.2 | 5.20 | 3.48 | 0.00 | 0.00 | |
Maximum of Months | 31.70 | 21.71 | 17.20 | 14.90 | 22.47 | 330.00 | 665.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -13.9 | 31-JAN-01:00 | -14.5 | -17.2 | 1.50 | -25.9 | 0.00 | 0.00 |
February | -16.7 | 07-FEB-06:00 | -17.2 | -20.6 | 6.20 | -35.1 | 0.00 | 0.00 |
March | -13.3 | 07-MAR-05:19 | -13.9 | -16.7 | 2.43 | -32.2 | 0.00 | 0.00 |
April | -4.4 | 17-APR-05:00 | -5.3 | -7.8 | 2.10 | -20.5 | 35.00 | 151.50 |
May | 1.70 | 01-MAY-04:00 | 0.96 | 0.00 | 0.00 | -14.2 | 0.00 | 0.00 |
June | 6.70 | 04-JUN-04:00 | 5.40 | 3.90 | 2.10 | -7.3 | 20.00 | 104.00 |
July | 11.70 | 03-JUL-03:00 | 11.07 | 10.60 | 2.10 | -1.2 | 0.00 | 0.00 |
August | 11.10 | 01-AUG-04:00 | 10.75 | 10.60 | 2.10 | -0.8 | 0.00 | 0.00 |
September | 6.10 | 05-SEP-05:00 | 5.59 | 5.00 | 2.10 | -6.2 | 24.50 | 41.00 |
October | -2.8 | 17-OCT-04:10 | -3.2 | -4.0 | 2.18 | -19.4 | 0.00 | 0.00 |
November | -3.9 | 24-NOV-05:00 | -4.4 | -5.6 | 2.10 | -18.1 | 0.00 | 0.00 |
December | -18.9 | 11-DEC-05:00 | -19.4 | -23.3 | 2.10 | -35.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -18.9 | -19.4 | -23.3 | 0.00 | -35.1 | 0.00 | 0.00 | |
Maximum of Months | 11.70 | 11.07 | 10.60 | 6.20 | -0.8 | 35.00 | 151.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.21 | 11-JAN-17:00 | 11.10 | 9.40 | 10.30 | 6.55 | 0.00 | 0.00 |
February | 6.89 | 01-FEB-03:00 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 |
March | 17.82 | 14-MAR-12:00 | 25.00 | 13.90 | 6.20 | 14.10 | 197.00 | 562.50 |
April | 13.76 | 08-APR-13:00 | 20.60 | 8.90 | 10.30 | 9.72 | 268.50 | 325.50 |
May | 18.17 | 10-MAY-14:00 | 26.10 | 13.90 | 5.20 | 16.85 | 273.00 | 238.00 |
June | 23.74 | 27-JUN-12:00 | 30.60 | 21.10 | 9.30 | 21.09 | 304.00 | 606.00 |
July | 24.79 | 21-JUL-01:00 | 28.90 | 23.30 | 8.80 | 27.46 | 0.00 | 0.00 |
August | 23.41 | 13-AUG-15:00 | 29.40 | 21.10 | 9.80 | 19.87 | 212.00 | 276.00 |
September | 21.17 | 15-SEP-11:00 | 26.10 | 18.90 | 3.60 | 16.30 | 204.00 | 464.50 |
October | 15.22 | 12-OCT-14:00 | 18.30 | 13.30 | 10.30 | 9.13 | 148.00 | 367.50 |
November | 13.95 | 05-NOV-14:00 | 18.30 | 11.10 | 11.30 | 14.10 | 72.00 | 6.00 |
December | 12.40 | 01-DEC-10:00 | 15.00 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.89 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 24.79 | 30.60 | 23.30 | 12.90 | 27.46 | 304.00 | 606.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 9.40 | 11-JAN-13:00 | 10.00 | 9.66 | 12.90 | 5.54 | 95.50 | 2.00 |
February | 6.70 | 01-FEB-04:10 | 7.20 | 6.89 | 3.52 | 2.22 | 0.00 | 0.00 |
March | 15.00 | 14-MAR-10:20 | 20.33 | 16.96 | 4.80 | 10.49 | 159.17 | 592.83 |
April | 11.10 | 08-APR-21:00 | 13.90 | 12.23 | 12.90 | 9.72 | 0.00 | 0.00 |
May | 15.60 | 17-MAY-12:00 | 16.70 | 15.96 | 6.70 | 13.54 | 184.00 | 0.00 |
June | 21.70 | 27-JUN-14:00 | 25.60 | 22.78 | 8.20 | 16.85 | 255.50 | 530.00 |
July | 23.30 | 20-JUL-20:00 | 25.60 | 24.03 | 4.60 | 24.16 | 0.00 | 0.00 |
August | 21.70 | 14-AUG-03:20 | 23.70 | 22.19 | 5.00 | 21.90 | 0.00 | 0.00 |
September | 20.00 | 15-SEP-18:00 | 21.70 | 20.51 | 0.00 | 19.52 | 0.00 | 0.00 |
October | 14.40 | 01-OCT-07:19 | 14.60 | 14.50 | 3.77 | 10.56 | 67.50 | 30.17 |
November | 11.70 | 05-NOV-15:00 | 12.80 | 12.14 | 7.20 | 8.74 | 28.00 | 4.50 |
December | 11.10 | 01-DEC-12:00 | 13.90 | 12.22 | 10.30 | 6.35 | 158.00 | 84.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.70 | 7.20 | 6.89 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 23.30 | 25.60 | 24.03 | 12.90 | 24.16 | 255.50 | 592.83 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 7.32 | 12.49 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 6.57 | 19.26 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 7.29 | 28.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 9.34 | 37.44 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.19 | 46.60 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 15.07 | 54.01 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.20 | 50.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.01 | 43.20 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.27 | 32.93 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.18 | 21.28 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.32 | 12.54 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 9.45 | 10.96 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.30 | 30.86 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 6.57 | 10.96 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.01 | 54.01 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.303033E+10 | -.244827E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -582060013.0 | 59.00 | 0.00 | 0.00 |
February | 0.278728E+10 | -.226163E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -525650894.9 | 59.00 | 0.00 | 0.00 |
March | 0.310152E+10 | -.253111E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -570415666.3 | 59.00 | 0.00 | 0.00 |
April | 0.285177E+10 | -.231155E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -540223878.1 | 58.99 | 0.00 | 0.00 |
May | 0.278867E+10 | -.225594E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -532731652.1 | 58.99 | 0.00 | 0.00 |
June | 0.257833E+10 | -.207664E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -501693695.6 | 58.99 | 0.00 | 0.00 |
July | 0.249625E+10 | -.198184E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -514416844.0 | 58.99 | 0.00 | 0.00 |
August | 0.252062E+10 | -.200620E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -514422620.4 | 58.99 | 0.00 | 0.00 |
September | 0.244588E+10 | -.194288E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -502998716.1 | 58.99 | 0.00 | 0.00 |
October | 0.261873E+10 | -.207663E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -542105130.2 | 58.99 | 0.00 | 0.00 |
November | 0.267598E+10 | -.213047E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -545506871.6 | 58.99 | 0.00 | 0.00 |
December | 0.292857E+10 | -.234895E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -579622265.4 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.328239E+11 | -.263721E+11 | 8760.00 | -.645185E+10 | 58.99 | |||||
Minimum of Months | 0.244588E+10 | -.253111E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -582060013.0 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.310152E+10 | -.194288E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -501693695.6 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 255.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 262.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 339.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 371.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 332.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 430.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 439.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 406.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 289.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 314.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 258.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 230.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3928.50 | ||||||||||
Minimum of Months | 230.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 439.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.218265E+11 | 50543.16 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.215553E+11 | 50543.16 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.121002E+11 | 50543.16 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.423954E+10 | 50543.16 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.311737E+09 | 50543.16 | 01-MAY-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 5751376.72 | 4214.00 | 30-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.116232E+10 | 50543.16 | 09-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.488086E+10 | 50543.16 | 02-NOV-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.190677E+11 | 50543.16 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.851499E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.218265E+11 | 50543.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.576802E+11 | 261764.52 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.537348E+11 | 261764.52 | 01-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.251041E+11 | 261764.52 | 01-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.465906E+10 | 106275.16 | 17-APR-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 28977696.85 | 17417.73 | 01-MAY-06:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.108529E+10 | 62317.80 | 17-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.883633E+10 | 169808.29 | 24-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.502023E+11 | 261764.52 | 06-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.201331E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.576802E+11 | 261764.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.886871E+10 | 32592.86 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.892280E+10 | 32592.86 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.384872E+10 | 32592.86 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.147960E+10 | 32592.86 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.117269E+09 | 14575.71 | 07-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 2127575.03 | 1005.51 | 14-JUN-05:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 3637720.04 | 1044.92 | 30-SEP-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.392131E+09 | 32592.86 | 09-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.158297E+10 | 32592.86 | 03-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.796494E+10 | 32592.86 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.331829E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.892280E+10 | 32592.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.122973E+11 | 27545.69 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.120403E+11 | 27545.69 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.622443E+10 | 27545.69 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.286722E+10 | 27545.69 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.395725E+09 | 27545.69 | 01-MAY-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 22942052.16 | 6401.96 | 14-JUN-04:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 27800022.30 | 11109.21 | 30-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.982694E+09 | 27545.69 | 09-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.338819E+10 | 27545.69 | 03-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.112896E+11 | 27545.69 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.495361E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.122973E+11 | 27545.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.179395E+11 | 39553.91 | 31-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.168145E+11 | 43039.60 | 06-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.114810E+11 | 34425.76 | 06-MAR-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.585184E+10 | 26736.38 | 16-APR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.168182E+10 | 10969.79 | 11-MAY-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.263427E+09 | 9464.75 | 13-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 55764661.84 | 3783.88 | 31-AUG-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.389888E+09 | 8820.71 | 28-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.467993E+10 | 16882.52 | 08-OCT-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.820130E+10 | 22065.92 | 23-NOV-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.170929E+11 | 40580.34 | 10-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.844517E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.179395E+11 | 43039.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.413866E+09 | 0.327201E+09 | 8408.62 | 15-MAR-14:10 | 7167.09 | 0.00 |
April | 0.00 | 0.00 | 0.182803E+09 | 0.167308E+09 | 4754.22 | 08-APR-14:00 | 4051.10 | 0.00 |
May | 0.00 | 0.00 | 0.330082E+10 | 0.288442E+10 | 10500.43 | 10-MAY-15:00 | 8171.09 | 0.00 |
June | 0.00 | 0.00 | 0.124237E+11 | 0.974603E+10 | 21436.88 | 18-JUN-07:05 | 10982.45 | 0.00 |
July | 0.00 | 0.00 | 0.201787E+11 | 0.148495E+11 | 34983.58 | 21-JUL-02:55 | 19234.64 | 0.00 |
August | 0.00 | 0.00 | 0.175207E+11 | 0.137723E+11 | 25166.28 | 14-AUG-21:00 | 17561.18 | 0.00 |
September | 0.00 | 0.00 | 0.954254E+10 | 0.749513E+10 | 24046.15 | 17-SEP-07:03 | 15146.82 | 0.00 |
October | 0.00 | 0.00 | 0.140793E+10 | 0.116899E+10 | 7779.90 | 12-OCT-15:00 | 5829.62 | 0.00 |
November | 0.00 | 0.00 | 35625304.59 | 27348709.83 | 2435.71 | 04-NOV-16:00 | 1795.41 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.650067E+11 | 0.504383E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.201787E+11 | 0.148495E+11 | 34983.58 | 19234.64 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.376504E+10 | 0.308336E+10 | 55410.91 | 15-MAR-14:10 | 49314.71 | 0.00 |
April | 0.00 | 0.00 | 0.406152E+10 | 0.386831E+10 | 39649.35 | 08-APR-14:00 | 34665.21 | 0.00 |
May | 0.00 | 0.00 | 0.287378E+11 | 0.259869E+11 | 85399.02 | 31-MAY-21:23 | 83481.02 | 0.00 |
June | 0.00 | 0.00 | 0.733513E+11 | 0.582864E+11 | 127863.56 | 07-JUN-21:23 | 84899.35 | 0.00 |
July | 0.00 | 0.00 | 0.108424E+12 | 0.798528E+11 | 117839.83 | 15-JUL-13:55 | 78640.29 | 0.00 |
August | 0.00 | 0.00 | 0.917312E+11 | 0.724521E+11 | 123364.20 | 12-AUG-05:02 | 110244.59 | 0.00 |
September | 0.00 | 0.00 | 0.520105E+11 | 0.412495E+11 | 108857.59 | 26-SEP-05:03 | 82933.40 | 0.00 |
October | 0.00 | 0.00 | 0.897015E+10 | 0.768920E+10 | 81312.01 | 05-OCT-20:33 | 77413.26 | 0.00 |
November | 0.00 | 0.00 | 0.623381E+09 | 0.497708E+09 | 25788.72 | 04-NOV-15:10 | 19973.04 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.371675E+12 | 0.292966E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.108424E+12 | 0.798528E+11 | 127863.56 | 110244.59 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.738600E+09 | 0.637468E+09 | 9776.20 | 15-MAR-13:40 | 9035.23 | 0.00 |
April | 0.00 | 0.00 | 0.111300E+10 | 0.107782E+10 | 6368.23 | 08-APR-13:40 | 5832.80 | 0.00 |
May | 0.00 | 0.00 | 0.397170E+10 | 0.365207E+10 | 9134.84 | 10-MAY-15:00 | 7615.96 | 0.00 |
June | 0.00 | 0.00 | 0.957447E+10 | 0.783596E+10 | 17963.30 | 27-JUN-20:10 | 12255.68 | 0.00 |
July | 0.00 | 0.00 | 0.147658E+11 | 0.112646E+11 | 22370.63 | 20-JUL-20:10 | 15436.54 | 0.00 |
August | 0.00 | 0.00 | 0.136631E+11 | 0.112145E+11 | 21527.41 | 10-AUG-20:43 | 17904.16 | 0.00 |
September | 0.00 | 0.00 | 0.928843E+10 | 0.782306E+10 | 16366.62 | 15-SEP-20:10 | 11659.79 | 0.00 |
October | 0.00 | 0.00 | 0.315737E+10 | 0.287245E+10 | 10941.06 | 11-OCT-14:30 | 10215.07 | 0.00 |
November | 0.00 | 0.00 | 0.631445E+09 | 0.584842E+09 | 4960.62 | 04-NOV-14:40 | 4081.18 | 0.00 |
December | 0.00 | 0.00 | 1205307.31 | 1205307.31 | 350.02 | 16-DEC-13:40 | 350.02 | 0.00 |
Annual Sum or Average | 0.569052E+11 | 0.469639E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.147658E+11 | 0.112646E+11 | 22370.63 | 17904.16 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.337918E+09 | 0.278410E+09 | 7137.16 | 15-MAR-13:50 | 6430.83 | 0.00 |
April | 0.00 | 0.00 | 0.261860E+09 | 0.249857E+09 | 3870.55 | 08-APR-13:40 | 3425.77 | 0.00 |
May | 0.00 | 0.00 | 0.144482E+10 | 0.129083E+10 | 6475.73 | 10-MAY-15:00 | 5152.17 | 0.00 |
June | 0.00 | 0.00 | 0.600398E+10 | 0.463241E+10 | 12522.64 | 27-JUN-13:00 | 8577.00 | 0.00 |
July | 0.00 | 0.00 | 0.107186E+11 | 0.773499E+10 | 18840.85 | 20-JUL-20:10 | 12056.19 | 0.00 |
August | 0.00 | 0.00 | 0.963872E+10 | 0.758910E+10 | 18388.07 | 13-AUG-18:10 | 12166.10 | 0.00 |
September | 0.00 | 0.00 | 0.587160E+10 | 0.471325E+10 | 12019.07 | 16-SEP-13:30 | 9512.32 | 0.00 |
October | 0.00 | 0.00 | 0.128968E+10 | 0.112873E+10 | 8396.47 | 11-OCT-14:40 | 7634.55 | 0.00 |
November | 0.00 | 0.00 | 0.100900E+09 | 87547809.58 | 2075.92 | 04-NOV-14:50 | 1591.93 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.356681E+11 | 0.277051E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.107186E+11 | 0.773499E+10 | 18840.85 | 12166.10 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.508869E+10 | 0.63 | 2806.39 | 01-JAN-00:10 | 0.92 |
February | 0.470454E+10 | 0.64 | 2806.39 | 01-FEB-00:05 | 0.93 |
March | 0.426348E+10 | 0.52 | 2806.39 | 01-MAR-03:10 | 0.92 |
April | 0.393293E+10 | 0.50 | 2806.39 | 01-APR-04:01 | 0.92 |
May | 0.276502E+10 | 0.34 | 2806.39 | 01-MAY-04:02 | 0.92 |
June | 0.104903E+10 | 0.13 | 2806.39 | 01-JUN-07:10 | 0.91 |
July | 47191399.84 | 0.01 | 2806.39 | 01-JUL-07:10 | 0.91 |
August | 0.289641E+09 | 0.04 | 2806.39 | 01-AUG-07:04 | 0.91 |
September | 0.147213E+10 | 0.19 | 2806.39 | 01-SEP-07:05 | 0.91 |
October | 0.342160E+10 | 0.42 | 2806.39 | 01-OCT-07:05 | 0.91 |
November | 0.392600E+10 | 0.50 | 2806.39 | 01-NOV-04:03 | 0.92 |
December | 0.494830E+10 | 0.61 | 2806.39 | 01-DEC-05:01 | 0.92 |
Annual Sum or Average | 0.359086E+11 | 0.37 | |||
Minimum of Months | 47191399.84 | 0.01 | 2806.39 | 0.91 | |
Maximum of Months | 0.508869E+10 | 0.64 | 2806.39 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.336636E+10 | 0.63 | 2005.31 | 01-JAN-09:20 | 0.92 |
February | 0.310231E+10 | 0.65 | 2005.31 | 03-FEB-19:50 | 0.92 |
March | 0.336029E+10 | 0.60 | 2005.31 | 01-MAR-06:55 | 0.92 |
April | 0.318448E+10 | 0.58 | 2005.31 | 03-APR-09:40 | 0.92 |
May | 0.324534E+10 | 0.56 | 2005.31 | 02-MAY-05:37 | 0.92 |
June | 0.317645E+10 | 0.57 | 2005.31 | 02-JUN-11:00 | 0.91 |
July | 0.331170E+10 | 0.62 | 2005.31 | 03-JUL-15:50 | 0.91 |
August | 0.332961E+10 | 0.61 | 2005.31 | 02-AUG-07:07 | 0.91 |
September | 0.315234E+10 | 0.56 | 2005.31 | 04-SEP-13:10 | 0.92 |
October | 0.322635E+10 | 0.56 | 2005.31 | 02-OCT-17:10 | 0.91 |
November | 0.314371E+10 | 0.57 | 2005.31 | 01-NOV-07:00 | 0.92 |
December | 0.336112E+10 | 0.62 | 2005.31 | 01-DEC-18:40 | 0.92 |
Annual Sum or Average | 0.389601E+11 | 0.59 | |||
Minimum of Months | 0.310231E+10 | 0.56 | 2005.31 | 0.91 | |
Maximum of Months | 0.336636E+10 | 0.65 | 2005.31 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.224123E+11 | 0.87 | 13986.59 | 01-JAN-16:40 | 1.45 |
February | 0.203596E+11 | 0.88 | 13986.59 | 01-FEB-10:10 | 1.45 |
March | 0.228119E+11 | 0.88 | 13986.59 | 01-MAR-09:30 | 1.45 |
April | 0.219030E+11 | 0.87 | 13986.59 | 01-APR-19:35 | 1.45 |
May | 0.226750E+11 | 0.88 | 13986.59 | 01-MAY-06:30 | 1.44 |
June | 0.226011E+11 | 0.97 | 13986.59 | 02-JUN-18:00 | 1.44 |
July | 0.235665E+11 | 1.07 | 13986.59 | 06-JUL-07:55 | 1.44 |
August | 0.237556E+11 | 1.06 | 13986.59 | 02-AUG-17:30 | 1.44 |
September | 0.222881E+11 | 0.94 | 13986.59 | 02-SEP-18:30 | 1.44 |
October | 0.224204E+11 | 0.87 | 13986.59 | 01-OCT-11:00 | 1.43 |
November | 0.216009E+11 | 0.86 | 13986.59 | 03-NOV-06:50 | 1.45 |
December | 0.224646E+11 | 0.87 | 13986.59 | 02-DEC-21:04 | 1.45 |
Annual Sum or Average | 0.268859E+12 | 0.92 | |||
Minimum of Months | 0.203596E+11 | 0.86 | 13986.59 | 1.43 | |
Maximum of Months | 0.237556E+11 | 1.07 | 13986.59 | 1.45 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.208002E+10 | 0.64 | 1260.24 | 01-JAN-09:20 | 0.96 |
February | 0.190754E+10 | 0.67 | 1260.24 | 04-FEB-14:00 | 0.96 |
March | 0.208401E+10 | 0.61 | 1260.24 | 01-MAR-06:08 | 0.96 |
April | 0.198565E+10 | 0.60 | 1260.24 | 01-APR-05:50 | 0.96 |
May | 0.203873E+10 | 0.58 | 1260.24 | 24-MAY-11:50 | 0.95 |
June | 0.202077E+10 | 0.65 | 1260.24 | 15-JUN-19:13 | 0.96 |
July | 0.213155E+10 | 0.74 | 1260.24 | 11-JUL-05:30 | 0.95 |
August | 0.215313E+10 | 0.74 | 1260.24 | 01-AUG-05:02 | 0.95 |
September | 0.201701E+10 | 0.66 | 1260.24 | 23-SEP-17:25 | 0.95 |
October | 0.202450E+10 | 0.58 | 1260.24 | 01-OCT-09:20 | 0.95 |
November | 0.196060E+10 | 0.59 | 1260.24 | 01-NOV-11:50 | 0.96 |
December | 0.207970E+10 | 0.64 | 1260.24 | 07-DEC-18:50 | 0.96 |
Annual Sum or Average | 0.244832E+11 | 0.64 | |||
Minimum of Months | 0.190754E+10 | 0.58 | 1260.24 | 0.95 | |
Maximum of Months | 0.215313E+10 | 0.74 | 1260.24 | 0.96 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.167369E+10 | 0.67 | 1000.08 | 03-JAN-06:35 | 0.96 |
February | 0.154031E+10 | 0.69 | 1000.08 | 01-FEB-10:00 | 0.96 |
March | 0.166550E+10 | 0.62 | 1000.08 | 04-MAR-21:50 | 0.96 |
April | 0.158457E+10 | 0.60 | 1000.08 | 01-APR-18:20 | 0.96 |
May | 0.161929E+10 | 0.58 | 1000.08 | 02-MAY-06:03 | 0.96 |
June | 0.158609E+10 | 0.60 | 1000.08 | 13-JUN-14:50 | 0.95 |
July | 0.166293E+10 | 0.67 | 1000.08 | 15-JUL-17:20 | 0.95 |
August | 0.167909E+10 | 0.67 | 1000.08 | 04-AUG-18:50 | 0.95 |
September | 0.158458E+10 | 0.62 | 1000.08 | 09-SEP-17:08 | 0.95 |
October | 0.160883E+10 | 0.59 | 1000.08 | 06-OCT-15:00 | 0.95 |
November | 0.156363E+10 | 0.59 | 1000.08 | 02-NOV-06:33 | 0.96 |
December | 0.167130E+10 | 0.66 | 1000.08 | 01-DEC-10:10 | 0.95 |
Annual Sum or Average | 0.194398E+11 | 0.63 | |||
Minimum of Months | 0.154031E+10 | 0.58 | 1000.08 | 0.95 | |
Maximum of Months | 0.167909E+10 | 0.69 | 1000.08 | 0.96 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.51 | 0.00 |
February | 3.26 | 0.00 |
March | 1.75 | 0.00 |
April | 0.53 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.06 | 0.00 |
November | 0.57 | 0.00 |
December | 3.65 | 0.00 |
Annual Sum or Average | 13.33 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.65 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.06 | 0.00 |
February | 0.06 | 0.00 |
March | 0.31 | 11.75 |
April | 0.92 | 23.49 |
May | 0.25 | 25.84 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.08 | 25.84 |
October | 0.93 | 25.84 |
November | 0.58 | 22.15 |
December | 0.00 | 0.00 |
Annual Sum or Average | 3.18 | 22.23 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.93 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.15 | 0.00 |
February | 1.90 | 0.00 |
March | 0.37 | 0.00 |
April | 0.10 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.04 | 0.00 |
December | 1.92 | 0.00 |
Annual Sum or Average | 6.48 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.15 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.09 | 0.00 |
February | 2.90 | 0.00 |
March | 0.89 | 0.00 |
April | 0.39 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.06 | 0.00 |
November | 0.42 | 0.00 |
December | 3.28 | 0.00 |
Annual Sum or Average | 11.04 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.28 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 74.85 | 0.00 |
February | 93.93 | 0.00 |
March | 48.67 | 0.00 |
April | 46.53 | 0.00 |
May | 52.96 | 0.00 |
June | 23.07 | 0.00 |
July | 5.45 | 0.00 |
August | 17.58 | 0.00 |
September | 34.80 | 0.00 |
October | 34.02 | 0.00 |
November | 44.90 | 0.00 |
December | 83.15 | 0.00 |
Annual Sum or Average | 559.91 | 0.00 |
Minimum of Months | 5.45 | 0.00 |
Maximum of Months | 93.93 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.336636E+10 | 0.272831E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.310231E+10 | 0.269441E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.348578E+10 | 0.151253E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.323940E+10 | 0.529942E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.422133E+10 | 0.389672E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.675843E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.910340E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.839621E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.589039E+10 | 7189220.90 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.364334E+10 | 0.145290E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.315452E+10 | 0.610107E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.336112E+10 | 0.238346E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.577226E+11 | 0.106437E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.310231E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.910340E+10 | 0.272831E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.224123E+11 | 0.727826E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.203596E+11 | 0.678042E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.240177E+11 | 0.316772E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.232025E+11 | 0.587894E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.316878E+11 | 36564917.16 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.451890E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.568899E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.522516E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.382901E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.252610E+11 | 0.136945E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.218015E+11 | 0.111499E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.224646E+11 | 0.633468E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.383828E+12 | 0.254046E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.203596E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.568899E+11 | 0.727826E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.208002E+10 | 0.110859E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.190754E+10 | 0.111535E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.229810E+10 | 0.481090E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.231058E+10 | 0.184950E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.318808E+10 | 0.146587E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.473748E+10 | 2659468.79 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.631118E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.603259E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.460590E+10 | 4547150.05 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.292332E+10 | 0.490164E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.214592E+10 | 0.197872E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.208007E+10 | 0.995618E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.406208E+11 | 0.414786E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.190754E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.631118E+10 | 0.111535E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.167369E+10 | 0.153716E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.154031E+10 | 0.150503E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.175466E+10 | 0.778053E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.165406E+10 | 0.358402E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.199951E+10 | 0.494657E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.312525E+10 | 28677565.20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.438872E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.414206E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.305915E+10 | 34750027.88 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.193861E+10 | 0.122837E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.159076E+10 | 0.423524E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.167130E+10 | 0.141120E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.285381E+11 | 0.619201E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.154031E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.438872E+10 | 0.153716E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.336636E+10 | 0.00 | 0.218265E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.310231E+10 | 0.00 | 0.215553E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.336029E+10 | 0.413866E+09 | 0.121002E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.318448E+10 | 0.182803E+09 | 0.423954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.324534E+10 | 0.330082E+10 | 0.311737E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.317645E+10 | 0.124237E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.331170E+10 | 0.201787E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.332961E+10 | 0.175207E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.315234E+10 | 0.954254E+10 | 5751376.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.322635E+10 | 0.140793E+10 | 0.116232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.314371E+10 | 35625304.59 | 0.488086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.336112E+10 | 0.00 | 0.190677E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.389601E+11 | 0.650067E+11 | 0.851499E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.310231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.336636E+10 | 0.201787E+11 | 0.218265E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.224123E+11 | 0.00 | 0.576802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.203596E+11 | 0.00 | 0.537348E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.228119E+11 | 0.376504E+10 | 0.251041E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219030E+11 | 0.406152E+10 | 0.465906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.226750E+11 | 0.287378E+11 | 28977696.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.226011E+11 | 0.733513E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.235665E+11 | 0.108424E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.237556E+11 | 0.917312E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.222881E+11 | 0.520105E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.224204E+11 | 0.897015E+10 | 0.108529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.216009E+11 | 0.623381E+09 | 0.883633E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.224646E+11 | 0.00 | 0.502023E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.268859E+12 | 0.371675E+12 | 0.201331E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.203596E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.237556E+11 | 0.108424E+12 | 0.576802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.208002E+10 | 0.00 | 0.886871E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.190754E+10 | 0.00 | 0.892280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208401E+10 | 0.738600E+09 | 0.384872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.198565E+10 | 0.111300E+10 | 0.147960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.203873E+10 | 0.397170E+10 | 0.117269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.202077E+10 | 0.957447E+10 | 2127575.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.213155E+10 | 0.147658E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.215313E+10 | 0.136631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.201701E+10 | 0.928843E+10 | 3637720.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.202450E+10 | 0.315737E+10 | 0.392131E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196060E+10 | 0.631445E+09 | 0.158297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.207970E+10 | 1205307.31 | 0.796494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.244832E+11 | 0.569052E+11 | 0.331829E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.190754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.215313E+10 | 0.147658E+11 | 0.892280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.167369E+10 | 0.00 | 0.122973E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.154031E+10 | 0.00 | 0.120403E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.166550E+10 | 0.337918E+09 | 0.622443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.158457E+10 | 0.261860E+09 | 0.286722E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.161929E+10 | 0.144482E+10 | 0.395725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.158609E+10 | 0.600398E+10 | 22942052.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.166293E+10 | 0.107186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.167909E+10 | 0.963872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.158458E+10 | 0.587160E+10 | 27800022.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.160883E+10 | 0.128968E+10 | 0.982694E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.156363E+10 | 0.100900E+09 | 0.338819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.167130E+10 | 0.00 | 0.112896E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194398E+11 | 0.356681E+11 | 0.495361E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.154031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.167909E+10 | 0.107186E+11 | 0.122973E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.336636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272831E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.310231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.269441E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.336029E+10 | 0.00 | 0.00 | 0.00 | 0.125490E+09 | 0.00 | 0.151253E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.318448E+10 | 0.00 | 0.00 | 0.00 | 54916206.10 | 0.00 | 0.529942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.324534E+10 | 0.00 | 0.00 | 0.00 | 0.975990E+09 | 0.00 | 0.389672E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.317645E+10 | 0.00 | 0.00 | 0.00 | 0.358198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.331170E+10 | 0.00 | 0.00 | 0.00 | 0.579169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.332961E+10 | 0.00 | 0.00 | 0.00 | 0.506659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.315234E+10 | 0.00 | 0.00 | 0.00 | 0.273805E+10 | 0.00 | 7189220.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.322635E+10 | 0.00 | 0.00 | 0.00 | 0.416992E+09 | 0.00 | 0.145290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.314371E+10 | 0.00 | 0.00 | 0.00 | 10812369.50 | 0.00 | 0.610107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.336112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238346E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.389601E+11 | 0.00 | 0.00 | 0.00 | 0.187625E+11 | 0.00 | 0.106437E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.310231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.336636E+10 | 0.00 | 0.00 | 0.00 | 0.579169E+10 | 0.00 | 0.272831E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.224123E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.727826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.203596E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.678042E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.228119E+11 | 0.00 | 0.00 | 0.00 | 0.120575E+10 | 0.00 | 0.316772E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219030E+11 | 0.00 | 0.00 | 0.00 | 0.129954E+10 | 0.00 | 0.587894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.226750E+11 | 0.00 | 0.00 | 0.00 | 0.901290E+10 | 0.00 | 36564917.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.226011E+11 | 0.00 | 0.00 | 0.00 | 0.225879E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.235665E+11 | 0.00 | 0.00 | 0.00 | 0.333234E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.237556E+11 | 0.00 | 0.00 | 0.00 | 0.284960E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.222881E+11 | 0.00 | 0.00 | 0.00 | 0.160020E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.224204E+11 | 0.00 | 0.00 | 0.00 | 0.284057E+10 | 0.00 | 0.136945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.216009E+11 | 0.00 | 0.00 | 0.00 | 0.200559E+09 | 0.00 | 0.111499E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.224646E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.633468E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.268859E+12 | 0.00 | 0.00 | 0.00 | 0.114969E+12 | 0.00 | 0.254046E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.203596E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.237556E+11 | 0.00 | 0.00 | 0.00 | 0.333234E+11 | 0.00 | 0.727826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.208002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.190754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111535E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208401E+10 | 0.00 | 0.00 | 0.00 | 0.214087E+09 | 0.00 | 0.481090E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.198565E+10 | 0.00 | 0.00 | 0.00 | 0.324924E+09 | 0.00 | 0.184950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.203873E+10 | 0.00 | 0.00 | 0.00 | 0.114936E+10 | 0.00 | 0.146587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.202077E+10 | 0.00 | 0.00 | 0.00 | 0.271670E+10 | 0.00 | 2659468.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.213155E+10 | 0.00 | 0.00 | 0.00 | 0.417963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.215313E+10 | 0.00 | 0.00 | 0.00 | 0.387946E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.201701E+10 | 0.00 | 0.00 | 0.00 | 0.258889E+10 | 0.00 | 4547150.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.202450E+10 | 0.00 | 0.00 | 0.00 | 0.898819E+09 | 0.00 | 0.490164E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196060E+10 | 0.00 | 0.00 | 0.00 | 0.185320E+09 | 0.00 | 0.197872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.207970E+10 | 0.00 | 0.00 | 0.00 | 367549.83 | 0.00 | 0.995618E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.244832E+11 | 0.00 | 0.00 | 0.00 | 0.161376E+11 | 0.00 | 0.414786E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.190754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.215313E+10 | 0.00 | 0.00 | 0.00 | 0.417963E+10 | 0.00 | 0.111535E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.167369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.154031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150503E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.166550E+10 | 0.00 | 0.00 | 0.00 | 89156796.22 | 0.00 | 0.778053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.158457E+10 | 0.00 | 0.00 | 0.00 | 69498149.31 | 0.00 | 0.358402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.161929E+10 | 0.00 | 0.00 | 0.00 | 0.380223E+09 | 0.00 | 0.494657E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.158609E+10 | 0.00 | 0.00 | 0.00 | 0.153915E+10 | 0.00 | 28677565.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.166293E+10 | 0.00 | 0.00 | 0.00 | 0.272579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.167909E+10 | 0.00 | 0.00 | 0.00 | 0.246297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.158458E+10 | 0.00 | 0.00 | 0.00 | 0.147458E+10 | 0.00 | 34750027.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.160883E+10 | 0.00 | 0.00 | 0.00 | 0.329776E+09 | 0.00 | 0.122837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.156363E+10 | 0.00 | 0.00 | 0.00 | 27133399.38 | 0.00 | 0.423524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.167130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141120E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194398E+11 | 0.00 | 0.00 | 0.00 | 0.909828E+10 | 0.00 | 0.619201E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.154031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.167909E+10 | 0.00 | 0.00 | 0.00 | 0.272579E+10 | 0.00 | 0.153716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 88777489.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121343E+11 | 0.00 | 0.00 | 0.23 |
February | 0.101567E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114355E+11 | 0.00 | 0.00 | 0.23 |
March | 0.204125E+10 | 0.00 | 0.00 | 403467.02 | 0.00 | 0.717602E+10 | 0.195614E+09 | 0.00 | 0.23 |
April | 0.419528E+10 | 0.00 | 0.00 | 307248.29 | 0.00 | 0.243969E+10 | 0.367780E+09 | 0.00 | 0.22 |
May | 0.220487E+10 | 19754098.15 | 0.00 | 5198762.05 | 0.00 | 0.227661E+09 | 0.248712E+10 | 0.00 | 0.22 |
June | 0.589383E+09 | 0.908982E+09 | 0.00 | 8860436.47 | 452653.26 | 0.00 | 0.162028E+10 | 0.00 | 0.22 |
July | 0.155811E+09 | 0.255449E+10 | 0.00 | 3403006.52 | 6776473.23 | 0.00 | 0.288445E+09 | 0.00 | 0.23 |
August | 0.256134E+09 | 0.135056E+10 | 0.00 | 9224897.27 | 1434399.54 | 0.00 | 0.845826E+09 | 0.00 | 0.23 |
September | 0.969107E+09 | 0.380669E+09 | 0.00 | 9134838.40 | 538408.56 | 753626.07 | 0.194452E+10 | 0.00 | 0.22 |
October | 0.436226E+10 | 0.00 | 0.00 | 2509767.12 | 0.00 | 0.698122E+09 | 0.147019E+10 | 0.00 | 0.22 |
November | 0.445985E+10 | 0.00 | 0.00 | 23848.96 | 0.00 | 0.292018E+10 | 68410231.66 | 29112.89 | 0.22 |
December | 0.786258E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108909E+11 | 0.00 | 0.00 | 0.23 |
Annual Sum or Average | 0.202106E+11 | 0.521446E+10 | 0.00 | 39066272.11 | 9201934.59 | 0.479231E+11 | 0.928818E+10 | 29112.89 | 0.22 |
Minimum of Months | 88777489.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.22 |
Maximum of Months | 0.445985E+10 | 0.255449E+10 | 0.00 | 9224897.27 | 6776473.23 | 0.121343E+11 | 0.248712E+10 | 29112.89 | 0.23 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.554592E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313741E+11 | 0.00 | 0.00 | 0.39 |
February | 0.532807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273401E+11 | 0.00 | 0.00 | 0.39 |
March | 0.538569E+11 | 32481618.49 | 0.00 | 4748849.29 | 0.00 | 0.104639E+11 | 0.311231E+10 | 0.00 | 0.40 |
April | 0.369110E+11 | 0.00 | 0.00 | 15461955.46 | 0.00 | 0.166337E+10 | 0.140272E+11 | 0.00 | 0.41 |
May | 0.793257E+10 | 0.270014E+09 | 0.00 | 66284976.64 | 3603670.15 | 0.00 | 0.293290E+11 | 0.00 | 0.44 |
June | 0.190175E+10 | 0.804894E+10 | 0.00 | 55557773.21 | 24529308.70 | 0.00 | 0.140484E+11 | 0.00 | 0.45 |
July | 61042974.79 | 0.206658E+11 | 0.00 | 15604937.73 | 47261817.41 | 0.00 | 0.307506E+10 | 0.00 | 0.45 |
August | 0.346453E+09 | 0.110624E+11 | 0.00 | 38953707.08 | 81529011.02 | 0.00 | 0.847878E+10 | 0.00 | 0.47 |
September | 0.339611E+10 | 0.332799E+10 | 0.00 | 57658158.00 | 9409165.11 | 0.00 | 0.203246E+11 | 0.00 | 0.47 |
October | 0.277377E+11 | 0.00 | 0.00 | 27817134.81 | 0.00 | 0.162695E+09 | 0.218283E+11 | 0.00 | 0.43 |
November | 0.492998E+11 | 0.00 | 0.00 | 2611622.58 | 0.00 | 0.269503E+10 | 0.351880E+10 | 0.00 | 0.40 |
December | 0.581631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249529E+11 | 0.00 | 0.00 | 0.39 |
Annual Sum or Average | 0.348346E+12 | 0.434076E+11 | 0.00 | 0.284699E+09 | 0.166333E+09 | 0.986521E+11 | 0.117742E+12 | 0.00 | 0.43 |
Minimum of Months | 61042974.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.39 |
Maximum of Months | 0.581631E+11 | 0.206658E+11 | 0.00 | 66284976.64 | 81529011.02 | 0.313741E+11 | 0.293290E+11 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.403905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490650E+10 | 0.00 | 0.00 | 0.43 |
February | 0.372249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.470396E+10 | 0.00 | 0.00 | 0.44 |
March | 0.437594E+10 | 12795257.66 | 0.00 | 968748.38 | 0.00 | 0.201557E+10 | 0.533520E+09 | 0.00 | 0.43 |
April | 0.269949E+10 | 0.00 | 0.00 | 3185436.14 | 0.00 | 0.876839E+09 | 0.161156E+10 | 0.00 | 0.43 |
May | 0.897685E+09 | 30027579.39 | 0.00 | 8482400.15 | 0.00 | 77083793.87 | 0.237316E+10 | 0.00 | 0.43 |
June | 0.375283E+09 | 0.870081E+09 | 0.00 | 7354812.08 | 739097.42 | 0.00 | 0.105945E+10 | 0.00 | 0.44 |
July | 99146097.03 | 0.232197E+10 | 0.00 | 2407785.03 | 1374010.25 | 0.00 | 0.177055E+09 | 0.00 | 0.45 |
August | 0.148676E+09 | 0.130242E+10 | 0.00 | 6874549.77 | 260389.29 | 0.00 | 0.505316E+09 | 0.00 | 0.45 |
September | 0.490385E+09 | 0.448673E+09 | 0.00 | 10773143.32 | 219417.12 | 0.00 | 0.139759E+10 | 0.00 | 0.44 |
October | 0.178487E+10 | 0.00 | 0.00 | 8040549.87 | 0.00 | 0.220238E+09 | 0.267049E+10 | 0.00 | 0.42 |
November | 0.365631E+10 | 0.00 | 0.00 | 1934132.42 | 0.00 | 0.808214E+09 | 0.113313E+10 | 0.00 | 0.42 |
December | 0.423087E+10 | 0.00 | 0.00 | 49041.41 | 0.00 | 0.426199E+10 | 66565587.50 | 0.00 | 0.43 |
Annual Sum or Average | 0.265202E+11 | 0.498596E+10 | 0.00 | 50070598.58 | 2592914.07 | 0.178704E+11 | 0.115278E+11 | 0.00 | 0.44 |
Minimum of Months | 99146097.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.437594E+10 | 0.232197E+10 | 0.00 | 10773143.32 | 1374010.25 | 0.490650E+10 | 0.267049E+10 | 0.00 | 0.45 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.109785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.796425E+10 | 0.00 | 0.00 | 0.44 |
February | 0.111151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.743992E+10 | 0.00 | 0.00 | 0.45 |
March | 0.308075E+10 | 5787438.57 | 0.00 | 240841.32 | 0.00 | 0.367047E+10 | 85731820.11 | 0.00 | 0.43 |
April | 0.270512E+10 | 0.00 | 0.00 | 733087.97 | 0.00 | 0.175413E+10 | 0.533620E+09 | 0.00 | 0.43 |
May | 0.165967E+10 | 20714340.83 | 0.00 | 2666102.48 | 0.00 | 0.261109E+09 | 0.139984E+10 | 0.00 | 0.43 |
June | 0.583691E+09 | 0.707881E+09 | 0.00 | 3832186.75 | 374992.73 | 2394751.25 | 0.918396E+09 | 0.00 | 0.44 |
July | 0.166135E+09 | 0.197218E+10 | 0.00 | 1547825.38 | 2279177.23 | 0.00 | 0.157396E+09 | 0.00 | 0.44 |
August | 0.284439E+09 | 0.112193E+10 | 0.00 | 4132916.76 | 616412.47 | 0.00 | 0.479103E+09 | 0.00 | 0.44 |
September | 0.814228E+09 | 0.345685E+09 | 0.00 | 6026808.32 | 816601.44 | 14385167.06 | 0.113072E+10 | 0.00 | 0.43 |
October | 0.285256E+10 | 0.00 | 0.00 | 2882149.67 | 0.00 | 0.592811E+09 | 0.109794E+10 | 0.00 | 0.42 |
November | 0.314209E+10 | 0.00 | 0.00 | 338418.27 | 0.00 | 0.196504E+10 | 0.335459E+09 | 0.00 | 0.43 |
December | 0.991401E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.765195E+10 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.184894E+11 | 0.417417E+10 | 0.00 | 22400336.93 | 4087183.88 | 0.313165E+11 | 0.613821E+10 | 0.00 | 0.44 |
Minimum of Months | 0.166135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.314209E+10 | 0.197218E+10 | 0.00 | 6026808.32 | 2279177.23 | 0.796425E+10 | 0.139984E+10 | 0.00 | 0.45 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |