Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Simulation Timestamp: 2020-06-03 19:11:33
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1059.45 | 461.84 | 461.84 |
Net Site Energy | 1059.45 | 461.84 | 461.84 |
Total Source Energy | 3145.70 | 1371.28 | 1371.28 |
Net Source Energy | 3145.70 | 1371.28 | 1371.28 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 13.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 368.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 230.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 38.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 126.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 87.54 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 958.84 | 100.62 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 13.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 368.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 230.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 38.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 194.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 126.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 87.54 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 117.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 216.10 | 43.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 417.98 | 43.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 117.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 216.10 | 43.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 417.98 | 43.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 958.836 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 958.836 | 100.00 |
Total On-Site and Utility Electric Sources | 958.836 | 100.00 |
Total Electricity End Uses | 958.836 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 726.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
Latitude [deg] | 27.85 |
Longitude [deg] | -82.5 |
Elevation [m] | 8.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 4.6739 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 11.3021 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.3021 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.3021 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 9.0417 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.1926 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.1926 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 22-JUL-15:00 | 05-FEB-09:20 | - | - | - | 03-JAN-12:09 |
Heating | 0.00 | 82222.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 52736.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 15871.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 10428.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 4526.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 89776.37 | 86749.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 82222.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 52736.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 15871.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 10428.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 4526.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 14.17 | 0.00 | 0.00 | 0.00 |
Cooling | 1168.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 729.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 121.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 615.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 401.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 94.90 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3036.63 | 109.07 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 6.18 | 0.00 | 0.00 | 0.00 |
Cooling | 509.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 318.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 53.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 175.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 41.37 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1323.73 | 47.55 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 6.18 | 0.00 | 0.00 | 0.00 |
Cooling | 509.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 318.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 53.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 175.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 41.37 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1323.73 | 47.55 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 1.84 |
CORE_RETAIL DIRECT AIR | 6.57 |
POINT_OF_SALE DIRECT AIR | 1.07 |
FRONT_RETAIL DIRECT AIR | 0.822874 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 0.842689 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 0.842689 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 24845.40 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 47010.61 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 189999.58 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 28331.31 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 22532.43 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 1.84 | 1.84 | 1.84 | 1.84 | 1.86 | 1.86 | 1.00 | 0.989113 | 1.86 |
PSZ-AC:2 | 6.57 | 6.57 | 6.57 | 6.57 | 6.81 | 6.81 | 1.00 | 0.964662 | 6.81 |
PSZ-AC:3 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.00 | 1.00 | 1.07 |
PSZ-AC:4 | 0.822874 | 0.822874 | 0.822874 | 0.822874 | 0.823510 | 0.823510 | 1.00 | 0.999228 | 0.823510 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 1.86 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 6.81 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.07 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.823510 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 1.86 | 1.86 | 1.86 | 1.23 | 38494.99 | 47010.61 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 6.81 | 6.81 | 6.81 | 4.49 | 169055.10 | 189999.58 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.07 | 1.07 | 1.07 | 0.708608 | 23793.73 | 28331.31 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.823510 | 0.823510 | 0.823510 | 0.543516 | 19488.62 | 22532.43 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 1.86 | 0.928730 | 1.24 | 36196.24 | 38494.99 | 19247.49 | 19247.49 | 0.724662 | 0.724660 | 0.724660 | 0.724660 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 6.81 | 3.40 | 4.54 | 169055.13 | 169055.10 | 84527.55 | 84527.55 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.07 | 0.536825 | 0.715767 | 22459.13 | 23793.73 | 11896.86 | 11896.86 | 0.705620 | 0.705620 | 0.705620 | 0.705620 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.823510 | 0.411755 | 0.549007 | 18485.29 | 19488.62 | 9744.31 | 9744.31 | 0.688170 | 0.688170 | 0.688170 | 0.688170 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.86 | 1987.57 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 6.81 | 11469.28 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.07 | 1188.70 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.823510 | 911.76 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 24.20 | 18.90 | 15.70 | 13.60 | 15.50 | 17.10 | 21.20 | 26.90 | 27.60 | 27.90 | 27.40 | 26.20 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 | 27.85 | -82.52 | -5.00 | 8.00 | 101229 | 1.2032 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 21.85 | 14.30 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 4.674 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 12.744 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 11.302 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 14.532 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 11.302 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 32.822 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 11.302 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 14.532 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 9.042 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.042 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 1775.580 | 4.674 | 28.946 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1775.580 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 18088.827 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 18088.827 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 1704.471 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1704.471 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 1704.471 | 11.302 | 69.994 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1704.471 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 108.500 | 9.042 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 108.500 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.761 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2284 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.9837 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5677 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8493 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.7613636 | 1.7613636 | 1.7613636 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
21 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
22 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
23 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
24 | 9 | 0.31844121E-15 | 0.33891907E-16 | -0.14717764E-09 | -0.34085343E-17 |
25 | 8 | 0.21517510E-07 | 0.13210865E-12 | 0.37403321E-03 | -0.24466149E-09 |
26 | 7 | -0.12129356E-01 | 0.68855956E-08 | -0.22924263E-01 | 0.13791520E-03 |
27 | 6 | 0.40230169 | 0.24029480E-05 | 0.46949424 | -0.47118258E-02 |
28 | 5 | -5.1608121 | 0.89965799E-04 | -4.4213154 | 0.62814943E-01 |
29 | 4 | 32.871256 | 0.73775273E-03 | 21.362378 | -0.42037561 |
30 | 3 | -110.94624 | 0.16114037E-02 | -55.469893 | 1.5111496 |
31 | 2 | 196.85374 | 0.90819125E-03 | 77.733479 | -2.8963115 |
32 | 1 | -171.06207 | 0.97128343E-04 | -55.213590 | 2.7437919 |
33 | 0 | 57.057407 | 0.55402955E-06 | 15.565444 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.45_SHGC_0.25 | 30 | 1 | VerySmooth | 2.557 | 0.252 | 0.162 | 0.276 |
2 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 31 | 1 | VerySmooth | 3.695 | 0.297 | 0.195 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.66719E-002 | 0.16139 | 0.61727 | 0.61727 | 0.27500 | 0.15630 | 0.22588 | 0.00000 | 0.84000 | 0.84000 | 0.12129 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.19440 | 0.51093 | 0.51093 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.96142E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1915 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 1.419 | 0.118 | 3.899E-002 | 69.771 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 21685.63290 | 26022.75947 | 1.53103 | 1.83724 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 28.05400 | 1.65138E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 18105.96221 | 21727.15465 | 0.75911 | 0.91093 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4.60000 | 5.25715E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 78020.77315 | 93624.92778 | 5.47273 | 6.56727 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 28.05400 | 1.65138E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 49116.98349 | 58940.38019 | 2.02800 | 2.43361 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4.60000 | 5.25715E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 12531.60240 | 15037.92288 | 0.89471 | 1.07365 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 28.05400 | 1.65138E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 8803.57996 | 10564.29595 | 0.37084 | 0.44500 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4.60000 | 5.25715E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 9678.26665 | 11613.91997 | 0.68573 | 0.82287 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 28.05400 | 1.65138E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 8803.57996 | 10564.29595 | 0.37084 | 0.44500 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4.60000 | 5.25715E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.90000 | 1.65138E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 20701.20340 | 24841.44408 | 0.70224 | 0.84269 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 4.60000 | 5.25715E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 26200.52 | 1.85746 | 1.85746 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 25607.86 | 0.91093 | 0.91093 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 106342.72 | 6.80785 | 6.80785 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 93574.82 | 2.43361 | 2.43361 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 15938.97 | 1.07365 | 1.07365 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 13794.54 | 0.44500 | 0.44500 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 13120.01 | 0.82351 | 0.82351 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 13794.54 | 0.44500 | 0.44500 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.83724 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.56727 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.07365 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.82287 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.84269 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 0.84269 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 24845.40313 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.83724 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.83724 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.83724 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.83724 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.85746 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.85746 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.98911 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 6.56727 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 6.56727 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.56727 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 6.56727 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 6.80785 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 6.80785 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.96466 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.07365 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07365 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.07365 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.07365 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.07365 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.07365 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.82287 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.82287 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.82287 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.82287 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.82351 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.82351 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 0.99923 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 1.85746 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 6.80785 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.07365 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.82351 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.85746 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.85746 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.85746 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.85746 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.22592 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.85746 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.92873 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.23831 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 36196.24242 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 38494.99000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 19247.49500 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 19247.49500 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72466 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72466 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72466 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72466 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 38494.99000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 47010.61379 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.85746 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1987.56893 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 47010.61379 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 6.80785 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 6.80785 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 6.80785 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 6.80785 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 4.49318 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 6.80785 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 3.40393 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 4.53857 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 169055.12789 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 169055.10000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 84527.55000 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 84527.55000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 169055.10000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 189999.57510 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 6.80785 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 11469.28251 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 189999.57510 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.07365 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.07365 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.07365 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.07365 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70861 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.07365 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53683 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.71577 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22459.12600 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23793.73000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11896.86500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11896.86500 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70562 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70562 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70562 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70562 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23793.73000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28331.31242 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.07365 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1188.69882 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 28331.31242 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.82351 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.82351 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.82351 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.82351 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.54352 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.82351 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.41176 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.54901 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 18485.28613 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 19488.62000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 9744.31000 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 9744.31000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68817 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68817 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68817 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68817 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 19488.62000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 22532.42811 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.82351 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 911.75575 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 22532.42811 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 37034.4 | 11.60 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 163684.3 | 13.31 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 22948.5 | 114.39 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18839.5 | 152.68 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.761 | 1.761 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | N/A | 3.695 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.45_SHGC_0.25 | N/A | 2.557 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.45_SHGC_0.25 | N/A | 2.557 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.45_SHGC_0.25 | N/A | 2.557 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 16 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 1.4640150399E-002 | 4.4835121689E-002 | Pass | Pass | 0.2890511553 | 1.9401686285 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 2.3731118042E-002 | 0.1095959066 | Pass | Pass | 3.8610953799E-002 | 0.1624578574 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 0.1864739061 | 0.3105205664 | Pass | Pass | 0.2823666351 | 0.9517828242 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 0.1203790775 | 0.2145571183 | Pass | Pass | 0.5802524828 | 2.1553880264 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.1606483790 | 0.3598503273 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 4.60 | 0.00 | 4.60 | Wetbulb [C] | 2.50 | 10.00 |
TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 7.90 | 25.10 | Wetbulb [C] | 3.10 | 270.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.65_SHGC_0.3 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.297 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.45_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.557 | 0.252 | 0.276 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.45_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.557 | 0.252 | 0.276 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.45_SHGC_0.25 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.557 | 0.252 | 0.276 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 2.809 | 0.262 | 0.303 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 2.809 | 0.262 | 0.303 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.394 | 1.761 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 4.6739 | 379.89 | 1775.58 | LightsWired | BLDG_LIGHT_BACK_SCH | 55.08 | 168.00 | 53.35 | 0.0000 | Y | 17.78 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 11.3021 | 1600.48 | 18088.83 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 50.48 | 0.0000 | Y | 171.40 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 11.3021 | 150.81 | 1704.47 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 65.23 | 0.0000 | Y | 20.87 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 11.3021 | 150.81 | 1704.47 | LightsWired | BLDG_LIGHT_FRONT_SCH | 67.15 | 168.00 | 63.20 | 0.0000 | Y | 20.22 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 9.0417 | 12.00 | 108.50 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 57.54 | 168.00 | 4.00 | 0.0000 | Y | 0.08 |
Interior Lighting Total | 10.1926 | 2293.99 | 23381.85 | 230.35 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 18088.83 | 4522.21 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 18088.83 | 4522.21 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 316.30 | AstronomicalClock | - | 41.73 | 41.73 | 2.48 | |
EXTERIOR_LIGHTS_B | 3054.90 | AstronomicalClock | - | 83.73 | 62.73 | 35.97 | |
Exterior Lighting Total | 3371.20 | 38.45 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 38494.99 | 27895.78 | 10599.21 | 0.72 | 3.80 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 169055.10 | 114294.77 | 54760.33 | 0.68 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23793.73 | 16789.33 | 7004.40 | 0.71 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 19488.62 | 13411.48 | 6077.14 | 0.69 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 37034.4 | 11.60 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 163684.3 | 13.31 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 22948.5 | 114.39 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18839.5 | 152.68 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 24845.40 | 0.81 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 47010.61 | 0.81 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 189999.58 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 28331.31 | 0.81 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 22532.43 | 0.81 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.84 | 932.99 | 1107.16 | 1.00 | 1.44 | General | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.86 | 1987.57 | 1070.05 | 1.00 | 1.33 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1018.41 | 6.81 | 11469.28 | 1684.71 | 1.00 | 1.16 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.07 | 1188.70 | 1107.16 | 1.00 | 1.39 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.82 | 911.76 | 1107.16 | 1.00 | 1.46 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 21685.63 | 26022.76 | 68.50 | 1.531 | 1.837 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.88 | 0.00984 | 28.05 | 0.01651 | 0.232 | 0.00 |
CORE_RETAIL | 78020.77 | 93624.93 | 58.50 | 5.473 | 6.567 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.88 | 0.01020 | 28.05 | 0.01651 | 1.890 | 0.00 |
POINT_OF_SALE | 12531.60 | 15037.92 | 99.71 | 0.895 | 1.074 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.89 | 0.00906 | 28.05 | 0.01651 | 0.178 | 0.00 |
FRONT_RETAIL | 9678.27 | 11613.92 | 77.01 | 0.686 | 0.823 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.89 | 0.00958 | 28.05 | 0.01651 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.48 | 100.00 | 0.00001 | 33.90 | 0.01651 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 18105.96 | 21727.15 | 57.19 | 0.759 | 0.911 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00756 | 4.60 | 0.00526 | 0.232 | 0.00 |
CORE_RETAIL | 49116.98 | 58940.38 | 36.83 | 2.028 | 2.434 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00782 | 4.60 | 0.00526 | 1.890 | 0.00 |
POINT_OF_SALE | 8803.58 | 10564.30 | 70.05 | 0.371 | 0.445 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00766 | 4.60 | 0.00526 | 0.178 | 0.00 |
FRONT_RETAIL | 8803.58 | 10564.30 | 70.05 | 0.371 | 0.445 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00766 | 4.60 | 0.00526 | 0.178 | 0.00 |
FRONT_ENTRY | 20701.20 | 24841.44 | 2070.12 | 0.702 | 0.843 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 16.00 | 15.97 | 0.00614 | 4.60 | 0.00526 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 1.86 | 1.86 | 0.91 | 0.91 | 1.8575 | 1.8372 | 1.8575 | 0.9891 | 1.0000 |
PSZ-AC:2 | 6.81 | 6.81 | 2.43 | 2.43 | 6.8078 | 6.5673 | 6.8078 | 0.9647 | 1.0000 |
PSZ-AC:3 | 1.07 | 1.07 | 0.45 | 0.45 | 1.0736 | 1.0736 | 1.0736 | 1.0000 | 1.0000 |
PSZ-AC:4 | 0.82 | 0.82 | 0.45 | 0.45 | 0.8235 | 0.8229 | 0.8235 | 0.9992 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 24845.403 | 24845.403 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 24845.40 | 24845.40 | 0.842689 | 15.78 | 10.90 | 0.00612267 | 40.00 | 21.14 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 0.0000 | 15.97 | 0.00613748 | 54.5031 | 24841.44 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 19247.495 | 0.000 | 1.857460 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 19247.49 | 13937.08 | 1.857460 | 24.47 | 18.16 | 0.01046722 | 12.80 | 12.09 | 0.00850000 | 28.55 | 0.01651377 | 23.71 | 12.4668 | 23.88 | 0.00984312 | 53.1965 | 21685.63 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 47010.614 | 47010.614 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 47010.61 | 47010.61 | 1.857459 | 16.75 | 12.18 | 0.00697461 | 40.00 | 21.14 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 12.4668 | 21.11 | 0.00756002 | 48.5404 | 18105.96 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 84527.550 | 0.000 | 6.807850 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 84527.55 | 56730.38 | 6.807850 | 26.93 | 19.76 | 0.01150760 | 12.80 | 12.09 | 0.00850000 | 33.90 | 0.01651378 | 25.10 | 27.7652 | 23.88 | 0.01019871 | 55.0896 | 77225.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 189999.575 | 189999.575 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 189999.58 | 189999.58 | 6.807849 | 8.20 | 7.12 | 0.00582925 | 40.00 | 21.14 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 27.7652 | 21.11 | 0.00781931 | 50.1822 | 49116.98 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 11896.865 | 0.000 | 1.073650 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 11896.86 | 8999.57 | 1.073650 | 25.62 | 18.42 | 0.01030970 | 12.80 | 12.09 | 0.00850000 | 33.90 | 0.01651378 | 25.10 | 16.5893 | 23.89 | 0.00905805 | 49.0071 | 11666.23 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 28331.312 | 28331.312 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 28331.31 | 28331.31 | 1.073648 | 14.36 | 10.89 | 0.00669701 | 40.00 | 21.14 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 16.5893 | 21.11 | 0.00765790 | 49.1612 | 8803.58 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 9744.310 | 0.000 | 0.823510 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 9744.31 | 7023.54 | 0.823510 | 26.07 | 18.90 | 0.01074601 | 12.80 | 12.09 | 0.00850000 | 33.90 | 0.01651378 | 25.10 | 21.6282 | 23.89 | 0.00957751 | 51.7808 | 9280.20 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 22532.428 | 22532.428 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 22532.43 | 22532.43 | 0.823510 | 14.36 | 10.89 | 0.00669701 | 40.00 | 21.14 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 21.6282 | 21.11 | 0.00765790 | 49.1612 | 8803.58 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 24845.403 | 24845.403 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.842689 | 1.01389502 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 24845.40 | 24845.40 | 1.0000 | 1.01389502 | 0.842689 | 15.78 | 10.90 | 0.00612267 | 31346.0 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24845.40 | 4.60 | 0.00525715 | 4.60 | 0.00000000 | 0.0000 | 15.97 | 0.00613748 | 15.97 | 0.00613748 | 54.5031 | 24841.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 19247.495 | 0.000 | 1.857460 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.2980 | 1004.8586 | 1.2032 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 19247.49 | 13937.08 | 1.0000 | 2.23483438 | 1.857460 | 24.47 | 18.16 | 0.01046722 | 51239.4 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19247.49 | 28.55 | 0.01651377 | 23.71 | 0.23156651 | 12.4668 | 23.88 | 0.00960605 | 23.88 | 0.00984312 | 53.1965 | 21685.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 47010.614 | 47010.614 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.857459 | 2.23483317 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 47010.61 | 47010.61 | 1.0000 | 2.23483317 | 1.857459 | 16.75 | 12.18 | 0.00697461 | 34489.5 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 47010.61 | 4.60 | 0.00525715 | 4.60 | 0.23156651 | 12.4668 | 20.89 | 0.00756002 | 21.11 | 0.00756002 | 48.5404 | 18105.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 84527.550 | 0.000 | 6.807850 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.2321 | 1004.8586 | 1.2032 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 84527.55 | 56730.38 | 1.0000 | 8.19097976 | 6.807850 | 26.93 | 19.76 | 0.01150760 | 56413.7 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 84527.55 | 33.90 | 0.01651378 | 25.10 | 1.89021192 | 27.7652 | 23.89 | 0.00932513 | 23.88 | 0.01019871 | 55.0896 | 77225.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 189999.575 | 189999.575 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 6.807849 | 8.19097829 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 189999.58 | 189999.58 | 1.0000 | 8.19097829 | 6.807849 | 8.20 | 7.12 | 0.00582925 | 22903.4 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 189999.58 | 4.60 | 0.00525715 | 4.60 | 1.89021192 | 27.7652 | 20.71 | 0.00781931 | 21.11 | 0.00781931 | 50.1822 | 49116.98 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11896.865 | 0.000 | 1.073650 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.0052 | 1004.8586 | 1.2032 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 11896.86 | 8999.57 | 1.0000 | 1.29178014 | 1.073650 | 25.62 | 18.42 | 0.01030970 | 52021.4 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11896.86 | 33.90 | 0.01651378 | 25.10 | 0.17811053 | 16.5893 | 23.89 | 0.00900976 | 23.89 | 0.00905805 | 49.0071 | 11666.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28331.312 | 28331.312 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.073648 | 1.29177779 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 28331.31 | 28331.31 | 1.0000 | 1.29177779 | 1.073648 | 14.36 | 10.89 | 0.00669701 | 31357.3 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28331.31 | 4.60 | 0.00525715 | 4.60 | 0.17811053 | 16.5893 | 20.87 | 0.00765790 | 21.11 | 0.00765790 | 49.1612 | 8803.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 9744.310 | 0.000 | 0.823510 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.8163 | 1004.8586 | 1.2032 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 9744.31 | 7023.54 | 1.0000 | 0.99081997 | 0.823510 | 26.07 | 18.90 | 0.01074601 | 53590.3 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9744.31 | 33.90 | 0.01651378 | 25.10 | 0.17811053 | 21.6282 | 23.89 | 0.00914027 | 23.89 | 0.00957751 | 51.7808 | 9280.20 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 22532.428 | 22532.428 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.823510 | 0.99081938 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 22532.43 | 22532.43 | 1.0000 | 0.99081938 | 0.823510 | 14.36 | 10.89 | 0.00669701 | 31357.3 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22532.43 | 4.60 | 0.00525715 | 4.60 | 0.17811053 | 21.6282 | 20.87 | 0.00765790 | 21.11 | 0.00765790 | 49.1612 | 8803.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:1_OA_CONTROLLER | DifferentialEnthalpy | 0.23 | 1.86 | - | |||
PSZ-AC:2_OA_CONTROLLER | DifferentialEnthalpy | 1.89 | 6.81 | - | |||
PSZ-AC:3_OA_CONTROLLER | DifferentialEnthalpy | 0.18 | 1.07 | - | |||
PSZ-AC:4_OA_CONTROLLER | DifferentialEnthalpy | 0.18 | 0.82 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 3155.67 | 1450.00 | 231.33 |
CORE_RETAIL | 3494.17 | 1609.67 | 622.67 |
POINT_OF_SALE | 3668.33 | 594.17 | 46.00 |
FRONT_RETAIL | 3532.17 | 1028.50 | 247.33 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3870.17 | 1959.33 | 726.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 1.33 | 10.17 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 0.17 | 201.83 | 0.00 | 0.00 |
FRONT_RETAIL | 0.50 | 58.00 | 0.00 | 0.00 |
FRONT_ENTRY | 241.17 | 0.00 | 0.00 | 0.00 |
Facility | 242.83 | 218.67 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.24 | 61.34 | 2317.33 | 0.480 | 0.022 | 0.000 | 0.000 |
CORE_RETAIL | 127.41 | 258.43 | 9762.95 | 0.783 | 0.004 | 0.000 | 0.000 |
POINT_OF_SALE | 12.01 | 24.35 | 919.94 | 0.938 | 0.024 | 0.000 | 0.000 |
FRONT_RETAIL | 12.01 | 24.35 | 919.94 | 0.829 | 0.024 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.24 | 61.34 | 2317.33 | 0.353 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 127.41 | 258.43 | 9762.95 | 0.684 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.01 | 24.35 | 919.94 | 0.685 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.01 | 24.35 | 919.94 | 0.684 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
Electricity:Building | 424.65 | 2265.44 | 01-JAN-00:10 | 31292.41 | 02-JAN-17:50 |
Electricity:Zone:BACK_SPACE | 67.55 | 535.60 | 01-JAN-00:10 | 4001.15 | 02-JAN-09:10 |
InteriorLights:Electricity | 230.35 | 493.85 | 01-JAN-00:10 | 20551.52 | 02-JAN-17:50 |
InteriorLights:Electricity:Zone:BACK_SPACE | 17.78 | 81.78 | 01-JAN-00:10 | 1249.73 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 230.35 | 493.85 | 01-JAN-00:10 | 20551.52 | 02-JAN-17:50 |
Electricity:Zone:CORE_RETAIL | 255.32 | 1109.80 | 01-JAN-00:10 | 20919.52 | 02-JAN-17:50 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 171.40 | 344.55 | 01-JAN-00:10 | 16279.94 | 02-JAN-17:50 |
Electricity:Zone:POINT_OF_SALE | 73.56 | 512.89 | 01-JAN-00:10 | 4446.74 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 20.87 | 32.47 | 01-JAN-00:10 | 1534.02 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 28.13 | 104.57 | 01-JAN-00:10 | 1922.42 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 20.22 | 32.47 | 01-JAN-00:10 | 1485.24 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 0.08 | 2.58 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 0.08 | 2.58 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 |
InteriorEquipment:Electricity | 194.30 | 1771.59 | 01-JAN-00:10 | 10740.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.77 | 453.82 | 01-JAN-00:10 | 2751.42 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 194.30 | 1771.59 | 01-JAN-00:10 | 10740.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 83.93 | 765.25 | 01-JAN-00:10 | 4639.58 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.69 | 480.42 | 01-JAN-00:10 | 2912.71 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.91 | 72.11 | 01-JAN-00:10 | 437.18 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
ElectricityPurchased:Plant | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
Cogeneration:ElectricityPurchased | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
ElectricityNet:Plant | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
Cogeneration:ElectricityNet | 958.84 | 2265.44 | 01-JAN-07:30 | 89776.37 | 22-JUL-16:00 |
Electricity:HVAC | 495.74 | 0.00 | 01-JAN-00:10 | 63164.13 | 22-JUL-16:00 |
Fans:Electricity | 126.88 | 0.00 | 01-JAN-00:10 | 10428.12 | 22-JUL-16:00 |
General:Fans:Electricity | 126.88 | 0.00 | 01-JAN-00:10 | 10428.12 | 22-JUL-16:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 368.86 | 0.00 | 01-JAN-00:10 | 52736.02 | 22-JUL-16:00 |
ExteriorLights:Electricity | 38.45 | 0.00 | 01-JAN-07:30 | 3371.20 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 38.45 | 0.00 | 01-JAN-07:30 | 3371.20 | 01-JAN-06:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 100.62 | 1860.00 | 03-JAN-18:10 | 86749.53 | 05-FEB-09:20 |
Gas:Plant | 87.54 | 1860.00 | 03-JAN-18:10 | 4930.30 | 23-JAN-13:00 |
WaterSystems:Gas | 87.54 | 1860.00 | 03-JAN-18:10 | 4930.30 | 23-JAN-13:00 |
Water Heater:WaterSystems:Gas | 87.54 | 1860.00 | 03-JAN-18:10 | 4930.30 | 23-JAN-13:00 |
Gas:HVAC | 13.07 | 0.00 | 01-JAN-00:10 | 82222.71 | 05-FEB-09:20 |
Heating:Gas | 13.07 | 0.00 | 01-JAN-00:10 | 82222.71 | 05-FEB-09:20 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2218.07 | 0.00 | 01-JAN-00:10 | 267095.41 | 07-OCT-13:00 |
EnergyTransfer:Building | 769.57 | 0.00 | 01-JAN-00:10 | 74976.27 | 07-JUL-14:50 |
EnergyTransfer:Zone:BACK_SPACE | 125.22 | 0.00 | 01-JAN-00:10 | 18364.89 | 05-FEB-07:10 |
Heating:EnergyTransfer | 6.96 | 0.00 | 01-JAN-00:10 | 34373.55 | 05-FEB-07:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 1.31 | 0.00 | 01-JAN-00:10 | 18364.89 | 05-FEB-07:10 |
Cooling:EnergyTransfer | 762.61 | 0.00 | 01-JAN-00:10 | 74976.27 | 07-JUL-14:50 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 123.91 | 0.00 | 01-JAN-00:10 | 13974.34 | 26-OCT-23:40 |
EnergyTransfer:Zone:CORE_RETAIL | 456.89 | 0.00 | 01-JAN-00:10 | 51976.94 | 09-JUL-08:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 4.13 | 0.00 | 01-JAN-00:10 | 9464.68 | 06-FEB-07:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 452.75 | 0.00 | 01-JAN-00:10 | 50457.91 | 27-OCT-06:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 110.79 | 0.00 | 01-JAN-00:10 | 10287.93 | 07-OCT-14:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 0.19 | 0.00 | 01-JAN-00:10 | 6936.26 | 05-FEB-07:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 110.60 | 0.00 | 01-JAN-00:10 | 10287.93 | 07-OCT-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 75.73 | 0.00 | 01-JAN-00:10 | 9072.41 | 05-FEB-07:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 0.38 | 0.00 | 01-JAN-00:10 | 9072.41 | 05-FEB-07:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 75.35 | 0.00 | 01-JAN-00:10 | 8344.10 | 07-OCT-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 0.95 | 0.00 | 01-JAN-00:10 | 21442.12 | 20-DEC-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 0.95 | 0.00 | 01-JAN-00:10 | 21442.12 | 20-DEC-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 1448.50 | 0.00 | 01-JAN-00:10 | 193420.91 | 07-OCT-13:00 |
HeatingCoils:EnergyTransfer | 10.51 | 0.00 | 01-JAN-00:10 | 66038.94 | 05-FEB-09:20 |
CoolingCoils:EnergyTransfer | 1437.99 | 0.00 | 01-JAN-00:10 | 193420.91 | 07-OCT-13:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 1.310 | -123.904 | 0.000 | 0.000 | 37.175 | 17.781 | 49.772 | 0.000 | 0.000 | 1.197 | 20.704 | 0.000 | 0.000 | 0.000 | -4.035 | -0.001 |
CORE_RETAIL | 0.000 | 0.000 | 4.134 | -452.745 | 0.000 | 0.000 | 156.449 | 171.396 | 83.927 | 35.450 | 0.000 | 0.741 | 16.468 | 0.000 | -12.033 | 0.000 | -3.787 | -0.001 |
POINT_OF_SALE | 0.000 | 0.000 | 0.191 | -110.602 | 0.000 | 0.000 | 14.612 | 20.870 | 52.689 | 31.749 | 0.000 | 0.516 | 0.587 | 0.000 | -8.722 | 0.000 | -1.891 | -0.002 |
FRONT_RETAIL | 0.000 | 0.000 | 0.375 | -75.349 | 0.000 | 0.000 | 14.708 | 20.222 | 7.908 | 31.681 | 0.000 | 0.518 | 10.210 | 0.000 | -8.459 | 0.000 | -1.813 | -0.000 |
FRONT_ENTRY | 0.949 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.081 | 0.000 | 6.165 | 0.000 | 1.862 | 0.121 | 0.000 | -1.740 | 0.000 | -7.437 | -0.000 |
Total Facility | 0.949 | 0.000 | 6.010 | -762.601 | 0.000 | 0.000 | 222.944 | 230.350 | 194.297 | 105.044 | 0.000 | 4.833 | 48.091 | 0.000 | -30.954 | 0.000 | -18.963 | -0.004 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 26-OCT-20:17 | 0.00 | 0.00 | 0.00 | -39204.93 | 0.00 | 0.00 | 0.00 | 81.78 | 605.09 | 0.00 | 0.00 | 0.00 | 38732.01 | 0.00 | -0.00 | 0.00 | -213.95 | 0.00 |
CORE_RETAIL | 27-OCT-06:02 | 0.00 | 0.00 | 0.00 | -194997.01 | 0.00 | 0.00 | 1627.14 | 344.55 | 2062.04 | 0.00 | 0.00 | 0.00 | 192245.81 | 0.00 | -1070.38 | 0.00 | -212.15 | 0.00 |
POINT_OF_SALE | 25-MAR-23:41 | 0.00 | 0.00 | 0.00 | -18521.91 | 0.00 | 0.00 | 0.00 | 32.47 | 480.42 | 0.00 | 0.00 | 0.00 | 18603.57 | 0.00 | -533.88 | 0.00 | -60.66 | 0.00 |
FRONT_RETAIL | 26-OCT-21:26 | 0.00 | 0.00 | 0.00 | -16245.21 | 0.00 | 0.00 | 0.00 | 32.47 | 96.14 | 0.00 | 0.00 | 0.00 | 16834.08 | 0.00 | -637.92 | 0.00 | -79.57 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 27-OCT-06:02 | 0.00 | 0.00 | 0.00 | -199807.11 | 0.00 | 0.00 | 2398.00 | 493.85 | 4773.73 | 0.00 | 0.00 | 0.00 | 195825.63 | 0.00 | -2995.16 | 0.00 | -688.95 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 19-FEB-08:61 | 0.00 | 0.00 | 47750.17 | 0.00 | 0.00 | 0.00 | 0.00 | 81.78 | 453.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -139.23 | -48146.54 |
CORE_RETAIL | 09-JUL-08:08 | 0.00 | 0.00 | 18318.50 | 0.00 | 0.00 | 0.00 | 1595.71 | 344.55 | 1546.53 | 1917.86 | 0.00 | 63.02 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -23786.16 |
POINT_OF_SALE | 05-FEB-07:01 | 0.00 | 0.00 | 28396.45 | 0.00 | 0.00 | 0.00 | 0.00 | 32.47 | 480.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1930.60 | 0.00 | -1077.70 | -25901.04 |
FRONT_RETAIL | 05-FEB-07:01 | 0.00 | 0.00 | 22755.64 | 0.00 | 0.00 | 0.00 | 0.00 | 32.47 | 72.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1878.23 | 0.00 | -1034.08 | -19947.90 |
FRONT_ENTRY | 04-JAN-17:21 | 21511.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.58 | 0.00 | 24.84 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -11124.55 | -10413.87 |
Total Facility | 05-FEB-07:01 | 0.00 | 0.00 | 98851.84 | 0.00 | 0.00 | 0.00 | 0.00 | 493.85 | 1771.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6323.15 | 0.00 | -6782.52 | -88011.61 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.8372 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.8575 | 0.1247 | 1.0000 | 0.2316 | 0.1247 | ||
PSZ-AC:2 | 6.5673 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 6.8078 | 0.2777 | 1.0000 | 1.8902 | 0.2777 | ||
PSZ-AC:3 | 1.0736 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0736 | 0.1659 | 1.0000 | 0.1781 | 0.1659 | ||
PSZ-AC:4 | 0.8229 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8235 | 0.2163 | 1.0000 | 0.1781 | 0.2163 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.8372 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.8372 | 1.0000 | 1.0000 | 0.2316 | 0.1260 | ||
PSZ-AC:2 | 6.5673 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 6.5673 | 1.0000 | 1.0000 | 1.8902 | 0.2878 | ||
PSZ-AC:3 | 1.0736 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0736 | 1.0000 | 1.0000 | 0.1781 | 0.1659 | ||
PSZ-AC:4 | 0.8229 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8229 | 1.0000 | 1.0000 | 0.1781 | 0.2164 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.8372 | 1.8372 | 1.8372 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 6.5673 | 6.5673 | 6.5673 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.0736 | 1.0736 | 1.0736 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8229 | 0.8229 | 0.8229 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.8372 | 1.8575 | 1.8372 | 1.8372 | 0.2316 | 1.0000 |
PSZ-AC:2 | 6.5673 | 6.8078 | 6.5673 | 6.5673 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.0736 | 1.0736 | 1.0736 | 1.0736 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8229 | 0.8235 | 0.8229 | 0.8229 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.8372 | 1.8372 | 1.8372 | 0.2316 | 0.2542 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 6.5673 | 6.5673 | 6.5673 | 1.8902 | 0.7767 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.0736 | 1.0736 | 1.0736 | 0.1781 | 0.4002 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8229 | 0.8229 | 0.8229 | 0.1781 | 0.4002 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.8372 | 1.8372 | 1.8372 | 1.8372 | 0.2316 | 1.0000 |
PSZ-AC:2 | 6.5673 | 6.5673 | 6.5673 | 6.5673 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.0736 | 1.0736 | 1.0736 | 1.0736 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8229 | 0.8229 | 0.8229 | 0.8229 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 13.07 | 82222.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 368.86 | 52736.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 230.35 | 20551.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 38.45 | 3371.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 194.30 | 10740.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 126.88 | 10428.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 87.54 | 4930.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 194.30 | 958.84 |
Natural Gas | 0.00 | 100.62 |
Additional | 0.00 | 0.00 |
Total | 194.30 | 1059.45 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 100.41 |
Space Heating | 0.00 |
Space Cooling | 160.79 |
Fans (All) | 55.31 |
Service Water Heating | 0.00 |
Receptacle Equipment | 84.70 |
Miscellaneous (All) | 417.98 |
Subtotal | 417.98 |
Natural Gas [MJ/m2] | |
Space Heating | 5.70 |
Service Water Heating | 38.16 |
Miscellaneous (All) | 43.86 |
Subtotal | 43.86 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 21.74 |
Space Heating | 1.23 |
Space Cooling | 34.82 |
Fans (All) | 11.98 |
Service Water Heating | 8.26 |
Receptacle Equipment | 18.34 |
Miscellaneous | 3.63 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 2872. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3001. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3501. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4552. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6570. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_SETBACK | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
HTGSETP_SCH_YES_OPTIMUM | CORE_RETAIL DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_RETAIL DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
HTGSETP_SCH_FRONTENTRY_STD2013 | FRONT_ENTRY DUALSPSCHED | January | 16.00 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.439866E+10 |
February | 0.000 | 0.356558E+10 |
March | 0.000 | 0.224369E+10 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.286639E+10 |
Annual Sum or Average | 0.130743E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.439866E+10 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.326480E+10 | 18086.99 | 01-JAN-20:50 | 19.00 | 17.57 | 0.200280E+10 | 2451.27 | 28-JAN-16:00 | 22.00 | 14.38 |
February | 0.353398E+10 | 17469.73 | 24-FEB-22:05 | 18.25 | 17.86 | 0.188932E+10 | 2451.28 | 09-FEB-15:09 | 22.02 | 14.61 |
March | 0.481634E+10 | 17310.37 | 28-MAR-21:25 | 18.55 | 17.79 | 0.219668E+10 | 2451.25 | 04-MAR-11:30 | 23.85 | 14.85 |
April | 0.802954E+10 | 29286.10 | 18-APR-20:32 | 20.00 | 16.98 | 0.215269E+10 | 2451.26 | 10-APR-14:09 | 20.42 | 10.76 |
May | 0.145620E+11 | 25430.45 | 07-MAY-18:13 | 30.57 | 23.65 | 0.223249E+10 | 2451.23 | 27-MAY-12:50 | 27.62 | 23.49 |
June | 0.159252E+11 | 24687.29 | 28-JUN-20:10 | 29.22 | 24.16 | 0.220161E+10 | 2451.23 | 17-JUN-12:30 | 30.00 | 25.17 |
July | 0.169324E+11 | 27058.32 | 07-JUL-21:23 | 28.85 | 25.01 | 0.218726E+10 | 2451.22 | 08-JUL-13:00 | 29.40 | 23.80 |
August | 0.173102E+11 | 28071.40 | 02-AUG-22:03 | 27.35 | 22.07 | 0.228102E+10 | 2451.22 | 23-AUG-14:09 | 31.33 | 25.62 |
September | 0.148782E+11 | 27989.58 | 10-SEP-22:03 | 27.97 | 24.30 | 0.215638E+10 | 2451.23 | 09-SEP-10:09 | 29.40 | 25.62 |
October | 0.132901E+11 | 39206.51 | 26-OCT-20:17 | 19.67 | 11.96 | 0.218278E+10 | 2451.31 | 28-OCT-13:00 | 21.00 | 14.47 |
November | 0.660708E+10 | 23727.38 | 08-NOV-05:22 | 19.70 | 18.97 | 0.208871E+10 | 2451.26 | 25-NOV-15:09 | 19.80 | 14.71 |
December | 0.475596E+10 | 29981.31 | 17-DEC-08:61 | 19.83 | 15.87 | 0.207050E+10 | 2451.29 | 02-DEC-16:00 | 20.00 | 16.82 |
Annual Sum or Average | 0.123906E+12 | 0.256422E+11 | ||||||||
Minimum of Months | 0.326480E+10 | 17310.37 | 18.25 | 11.96 | 0.188932E+10 | 2451.22 | 19.80 | 10.76 | ||
Maximum of Months | 0.173102E+11 | 39206.51 | 30.57 | 25.01 | 0.228102E+10 | 2451.31 | 31.33 | 25.62 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.247852E+11 | 130591.66 | 02-JAN-07:03 | 15.83 | 15.23 | 0.851284E+10 | 10327.28 | 11-JAN-15:00 | 20.00 | 14.61 |
February | 0.237862E+11 | 131649.57 | 25-FEB-07:03 | 14.77 | 14.77 | 0.802055E+10 | 10326.95 | 09-FEB-15:09 | 22.02 | 14.61 |
March | 0.291441E+11 | 136964.08 | 01-MAR-07:03 | 15.30 | 14.01 | 0.927852E+10 | 10326.95 | 04-MAR-16:00 | 24.40 | 14.55 |
April | 0.357500E+11 | 137817.22 | 18-APR-06:03 | 16.78 | 15.04 | 0.907121E+10 | 10327.20 | 10-APR-14:09 | 20.42 | 10.76 |
May | 0.462672E+11 | 107661.43 | 12-MAY-06:02 | 23.40 | 20.68 | 0.940918E+10 | 10327.16 | 12-MAY-14:50 | 32.12 | 22.95 |
June | 0.481989E+11 | 108278.83 | 12-JUN-06:02 | 23.58 | 21.07 | 0.927895E+10 | 10327.06 | 01-JUN-14:09 | 29.60 | 22.93 |
July | 0.489524E+11 | 94984.08 | 18-JUL-06:02 | 24.27 | 22.84 | 0.921873E+10 | 10326.95 | 13-JUL-14:00 | 25.60 | 23.63 |
August | 0.495757E+11 | 101322.88 | 04-AUG-06:02 | 25.68 | 23.49 | 0.961363E+10 | 10327.02 | 05-AUG-12:50 | 26.43 | 23.73 |
September | 0.441940E+11 | 107011.62 | 23-SEP-06:02 | 22.28 | 20.35 | 0.908836E+10 | 10327.09 | 07-SEP-14:09 | 24.30 | 22.91 |
October | 0.430192E+11 | 195031.19 | 27-OCT-06:02 | 14.83 | 7.55 | 0.919480E+10 | 10327.36 | 02-OCT-14:00 | 29.00 | 22.08 |
November | 0.308742E+11 | 131881.82 | 30-NOV-07:03 | 15.50 | 14.44 | 0.879260E+10 | 10327.36 | 14-NOV-15:50 | 18.38 | 13.09 |
December | 0.282042E+11 | 137258.72 | 17-DEC-09:02 | 19.00 | 14.28 | 0.872315E+10 | 10327.22 | 05-DEC-15:50 | 18.33 | 12.42 |
Annual Sum or Average | 0.452751E+12 | 0.108203E+12 | ||||||||
Minimum of Months | 0.237862E+11 | 94984.08 | 14.77 | 7.55 | 0.802055E+10 | 10326.95 | 18.33 | 10.76 | ||
Maximum of Months | 0.495757E+11 | 195031.19 | 25.68 | 23.49 | 0.961363E+10 | 10327.36 | 32.12 | 23.73 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.651107E+10 | 15913.56 | 01-JAN-08:61 | 16.50 | 14.99 | 0.853636E+09 | 973.22 | 07-JAN-12:00 | 19.00 | 13.75 |
February | 0.613051E+10 | 17464.44 | 01-FEB-23:01 | 17.75 | 17.13 | 0.780096E+09 | 973.16 | 09-FEB-15:09 | 22.02 | 14.61 |
March | 0.613397E+10 | 18524.26 | 25-MAR-23:41 | 19.65 | 16.46 | 0.888015E+09 | 973.14 | 04-MAR-11:09 | 23.48 | 14.90 |
April | 0.713122E+10 | 15316.19 | 30-APR-20:31 | 19.77 | 16.35 | 0.855132E+09 | 973.14 | 29-APR-13:39 | 30.37 | 24.24 |
May | 0.101985E+11 | 13811.26 | 07-MAY-18:43 | 27.22 | 24.15 | 0.886263E+09 | 973.15 | 01-MAY-14:50 | 32.02 | 25.22 |
June | 0.105648E+11 | 14193.21 | 28-JUN-20:10 | 29.22 | 24.16 | 0.873998E+09 | 973.13 | 03-JUN-14:00 | 31.10 | 24.21 |
July | 0.112137E+11 | 16563.77 | 07-JUL-21:23 | 28.85 | 25.01 | 0.868299E+09 | 973.11 | 01-JUL-15:30 | 25.85 | 24.41 |
August | 0.120541E+11 | 17848.99 | 30-AUG-21:23 | 28.90 | 22.60 | 0.905509E+09 | 973.11 | 05-AUG-13:00 | 27.70 | 25.21 |
September | 0.113740E+11 | 17703.88 | 10-SEP-22:03 | 27.97 | 24.30 | 0.856037E+09 | 973.14 | 22-SEP-14:20 | 30.17 | 21.87 |
October | 0.122153E+11 | 18135.65 | 05-OCT-23:23 | 26.50 | 24.49 | 0.866723E+09 | 973.20 | 02-OCT-14:50 | 28.83 | 21.64 |
November | 0.924796E+10 | 17301.19 | 22-NOV-21:15 | 15.93 | 9.21 | 0.833492E+09 | 973.17 | 14-NOV-15:00 | 18.30 | 13.15 |
December | 0.782829E+10 | 16695.04 | 03-DEC-08:61 | 13.00 | 13.00 | 0.857866E+09 | 973.17 | 05-DEC-15:00 | 18.00 | 12.40 |
Annual Sum or Average | 0.110603E+12 | 0.103251E+11 | ||||||||
Minimum of Months | 0.613051E+10 | 13811.26 | 13.00 | 9.21 | 0.780096E+09 | 973.11 | 18.00 | 12.40 | ||
Maximum of Months | 0.122153E+11 | 18524.26 | 29.22 | 25.01 | 0.905509E+09 | 973.22 | 32.02 | 25.22 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.408981E+10 | 12135.66 | 16-JAN-22:32 | 18.00 | 16.70 | 0.829716E+09 | 973.15 | 07-JAN-12:00 | 19.00 | 13.75 |
February | 0.378190E+10 | 11984.17 | 01-FEB-23:01 | 17.75 | 17.13 | 0.762692E+09 | 973.12 | 14-FEB-15:39 | 18.07 | 13.92 |
March | 0.354380E+10 | 15400.59 | 24-MAR-20:20 | 18.67 | 15.20 | 0.864264E+09 | 973.10 | 25-MAR-15:50 | 24.18 | 18.81 |
April | 0.425585E+10 | 14859.42 | 17-APR-20:41 | 21.37 | 14.47 | 0.851744E+09 | 973.12 | 10-APR-14:09 | 20.42 | 10.76 |
May | 0.692907E+10 | 11869.88 | 07-MAY-18:43 | 27.22 | 24.15 | 0.886256E+09 | 973.12 | 01-MAY-14:50 | 32.02 | 25.22 |
June | 0.733220E+10 | 11289.44 | 28-JUN-20:10 | 29.22 | 24.16 | 0.873995E+09 | 973.12 | 03-JUN-14:00 | 31.10 | 24.21 |
July | 0.802819E+10 | 13092.65 | 07-JUL-21:23 | 28.85 | 25.01 | 0.868299E+09 | 973.09 | 11-JUL-14:00 | 25.00 | 23.46 |
August | 0.874888E+10 | 14297.71 | 30-AUG-22:03 | 28.42 | 22.68 | 0.905508E+09 | 973.10 | 12-AUG-14:00 | 25.00 | 22.92 |
September | 0.816084E+10 | 14559.90 | 10-SEP-22:43 | 27.83 | 24.27 | 0.856031E+09 | 973.11 | 22-SEP-14:09 | 30.08 | 21.93 |
October | 0.897508E+10 | 16245.88 | 26-OCT-21:26 | 19.00 | 11.81 | 0.865970E+09 | 973.15 | 02-OCT-14:39 | 28.67 | 21.20 |
November | 0.631662E+10 | 13827.43 | 22-NOV-21:20 | 15.93 | 9.21 | 0.831180E+09 | 973.16 | 14-NOV-15:39 | 18.47 | 13.03 |
December | 0.518840E+10 | 15765.03 | 17-DEC-20:01 | 10.00 | 6.98 | 0.834034E+09 | 973.16 | 05-DEC-15:00 | 18.00 | 12.40 |
Annual Sum or Average | 0.753506E+11 | 0.102297E+11 | ||||||||
Minimum of Months | 0.354380E+10 | 11289.44 | 10.00 | 6.98 | 0.762692E+09 | 973.09 | 18.00 | 10.76 | ||
Maximum of Months | 0.897508E+10 | 16245.88 | 29.22 | 25.01 | 0.905508E+09 | 973.16 | 32.02 | 25.22 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 17.00 | 16.69 | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 17.62 | 17.16 | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 |
April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.10 | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 22.93 | 21.40 | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 25.07 | 23.10 | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 25.13 | 23.54 | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.54 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 24.85 | 24.22 | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 22.17 | 20.64 | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 21.63 | 21.01 | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 14.12 | 12.36 | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.00 | 0.00 | 14.12 | 12.36 | ||
Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.00 | 0.00 | 25.13 | 24.22 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.409987E+09 | 47071.09 | 10-JAN-05:02 | 1.33 |
February | 0.337471E+09 | 47750.19 | 19-FEB-08:61 | 12.57 |
March | 0.210779E+09 | 47662.77 | 12-MAR-06:01 | 7.10 |
April | 33007026.38 | 1033.36 | 15-APR-05:10 | 21.00 |
May | 5318421.20 | 1441.15 | 26-MAY-05:05 | 25.00 |
June | 4002414.80 | 1439.80 | 28-JUN-05:05 | 26.70 |
July | 4199966.57 | 1494.01 | 29-JUL-05:05 | 25.60 |
August | 4803870.23 | 1523.17 | 10-AUG-05:05 | 27.42 |
September | 8834740.28 | 1520.74 | 12-SEP-05:05 | 26.77 |
October | 11211184.06 | 1486.98 | 25-OCT-05:05 | 26.50 |
November | 49907464.12 | 1005.71 | 01-NOV-05:10 | 22.62 |
December | 0.230635E+09 | 47324.79 | 21-DEC-05:01 | 0.17 |
Annual Sum or Average | 0.131016E+10 | |||
Minimum of Months | 4002414.80 | 1005.71 | 0.17 | |
Maximum of Months | 0.409987E+09 | 47750.19 | 27.42 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.492713E+09 | 16510.30 | 23-JAN-07:10 | 6.17 |
February | 0.442979E+09 | 9464.68 | 06-FEB-07:10 | 3.90 |
March | 0.475495E+09 | 4560.01 | 12-MAR-07:11 | 7.33 |
April | 0.431100E+09 | 4520.87 | 02-APR-07:12 | 13.80 |
May | 0.241761E+09 | 13953.59 | 28-MAY-08:20 | 27.77 |
June | 0.205951E+09 | 15173.02 | 18-JUN-08:08 | 28.25 |
July | 0.227591E+09 | 18315.97 | 09-JUL-08:08 | 29.60 |
August | 0.180750E+09 | 15480.14 | 06-AUG-08:08 | 28.17 |
September | 0.219703E+09 | 14772.69 | 03-SEP-08:08 | 28.07 |
October | 0.275819E+09 | 11841.54 | 07-OCT-06:08 | 26.67 |
November | 0.453001E+09 | 7297.90 | 11-NOV-09:06 | 24.40 |
December | 0.487286E+09 | 5764.10 | 22-DEC-07:15 | 10.67 |
Annual Sum or Average | 0.413415E+10 | |||
Minimum of Months | 0.180750E+09 | 4520.87 | 3.90 | |
Maximum of Months | 0.492713E+09 | 18315.97 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 34525479.11 | 1097.73 | 21-JAN-07:10 | 1.17 |
February | 50892239.56 | 28396.45 | 05-FEB-07:01 | -3.4 |
March | 51575159.65 | 28366.91 | 12-MAR-06:01 | 7.10 |
April | 13344242.38 | 803.33 | 27-APR-05:05 | 20.92 |
May | 677975.59 | 841.72 | 27-MAY-05:05 | 25.00 |
June | 853944.46 | 832.98 | 19-JUN-05:05 | 25.00 |
July | 1021890.95 | 849.60 | 14-JUL-05:05 | 23.98 |
August | 320268.76 | 535.07 | 06-AUG-07:10 | 26.33 |
September | 1141991.88 | 841.41 | 16-SEP-05:05 | 23.80 |
October | 1191502.93 | 619.43 | 30-OCT-05:05 | 16.00 |
November | 6909623.82 | 831.35 | 29-NOV-06:05 | 21.60 |
December | 28444022.09 | 4770.86 | 21-DEC-07:37 | 2.00 |
Annual Sum or Average | 0.190898E+09 | |||
Minimum of Months | 320268.76 | 535.07 | -3.4 | |
Maximum of Months | 51575159.65 | 28396.45 | 26.33 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 59206747.02 | 22418.85 | 10-JAN-05:02 | 1.33 |
February | 89110018.87 | 22755.64 | 05-FEB-07:01 | -3.4 |
March | 0.116100E+09 | 22737.75 | 12-MAR-06:01 | 7.10 |
April | 18187024.93 | 517.18 | 30-APR-07:04 | 21.50 |
May | 1415492.75 | 626.59 | 22-MAY-05:05 | 26.10 |
June | 1246094.24 | 457.40 | 02-JUN-05:10 | 24.50 |
July | 397084.70 | 635.74 | 13-JUL-05:05 | 26.93 |
August | 656498.42 | 623.54 | 26-AUG-05:05 | 23.53 |
September | 1245768.79 | 614.15 | 08-SEP-05:05 | 24.58 |
October | 3012875.60 | 454.28 | 27-OCT-05:05 | 15.00 |
November | 13656611.39 | 606.05 | 01-NOV-05:05 | 22.62 |
December | 70835584.01 | 22554.92 | 21-DEC-05:01 | 0.17 |
Annual Sum or Average | 0.375069E+09 | |||
Minimum of Months | 397084.70 | 454.28 | -3.4 | |
Maximum of Months | 0.116100E+09 | 22755.64 | 26.93 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.183097E+09 | 21510.93 | 04-JAN-17:21 | 7.00 |
February | 0.399768E+09 | 21485.29 | 04-FEB-14:51 | 7.20 |
March | 0.111764E+09 | 17226.17 | 11-MAR-12:10 | 6.28 |
April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 22.93 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 25.07 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 24.85 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 22.17 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 21.63 |
December | 0.254004E+09 | 21487.56 | 30-DEC-17:51 | 7.00 |
Annual Sum or Average | 0.948632E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.28 | |
Maximum of Months | 0.399768E+09 | 21510.93 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.149153E+10 | 1249.73 | 02-JAN-09:09 | 0.419292E+10 | 2751.42 | 02-JAN-09:09 |
February | 0.135698E+10 | 1249.73 | 01-FEB-09:09 | 0.380401E+10 | 2751.42 | 01-FEB-09:09 |
March | 0.154631E+10 | 1249.73 | 01-MAR-09:09 | 0.429860E+10 | 2751.42 | 01-MAR-09:09 |
April | 0.146057E+10 | 1249.73 | 01-APR-09:09 | 0.408483E+10 | 2751.42 | 01-APR-09:09 |
May | 0.151892E+10 | 1249.73 | 01-MAY-08:09 | 0.424576E+10 | 2751.42 | 01-MAY-08:09 |
June | 0.149233E+10 | 1249.73 | 01-JUN-08:09 | 0.415135E+10 | 2751.42 | 01-JUN-08:09 |
July | 0.148716E+10 | 1249.73 | 01-JUL-09:09 | 0.417924E+10 | 2751.42 | 01-JUL-09:09 |
August | 0.154631E+10 | 1249.73 | 01-AUG-08:09 | 0.429860E+10 | 2751.42 | 01-AUG-08:09 |
September | 0.146057E+10 | 1249.73 | 01-SEP-08:09 | 0.408483E+10 | 2751.42 | 01-SEP-08:09 |
October | 0.149153E+10 | 1249.73 | 02-OCT-08:09 | 0.419292E+10 | 2751.42 | 02-OCT-08:09 |
November | 0.144192E+10 | 1249.73 | 01-NOV-08:09 | 0.405935E+10 | 2751.42 | 01-NOV-08:09 |
December | 0.148716E+10 | 1249.73 | 01-DEC-09:09 | 0.417924E+10 | 2751.42 | 01-DEC-09:09 |
Annual Sum or Average | 0.177813E+11 | 0.497716E+11 | ||||
Minimum of Months | 0.135698E+10 | 1249.73 | 0.380401E+10 | 2751.42 | ||
Maximum of Months | 0.154631E+10 | 1249.73 | 0.429860E+10 | 2751.42 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.161362E+11 | 16279.94 | 02-JAN-17:49 | 0.707031E+10 | 4639.58 | 02-JAN-09:09 |
February | 0.140486E+11 | 16030.10 | 04-FEB-17:00 | 0.641452E+10 | 4639.58 | 01-FEB-09:09 |
March | 0.151053E+11 | 15979.19 | 02-MAR-17:00 | 0.724851E+10 | 4639.58 | 01-MAR-09:09 |
April | 0.135623E+11 | 14820.70 | 14-APR-08:09 | 0.688804E+10 | 4639.58 | 01-APR-09:09 |
May | 0.138567E+11 | 14534.62 | 11-MAY-16:00 | 0.715941E+10 | 4639.58 | 01-MAY-08:09 |
June | 0.133760E+11 | 14548.53 | 20-JUN-16:30 | 0.700021E+10 | 4639.58 | 01-JUN-08:09 |
July | 0.129128E+11 | 14336.03 | 27-JUL-16:00 | 0.704724E+10 | 4639.58 | 01-JUL-09:09 |
August | 0.134166E+11 | 14679.60 | 30-AUG-16:00 | 0.724851E+10 | 4639.58 | 01-AUG-08:09 |
September | 0.129930E+11 | 15369.23 | 30-SEP-16:00 | 0.688804E+10 | 4639.58 | 01-SEP-08:09 |
October | 0.142864E+11 | 15756.37 | 21-OCT-16:00 | 0.707031E+10 | 4639.58 | 02-OCT-08:09 |
November | 0.154249E+11 | 16279.94 | 06-NOV-17:40 | 0.684509E+10 | 4639.58 | 01-NOV-08:09 |
December | 0.162771E+11 | 16279.94 | 01-DEC-17:40 | 0.704724E+10 | 4639.58 | 01-DEC-09:09 |
Annual Sum or Average | 0.171396E+12 | 0.839274E+11 | ||||
Minimum of Months | 0.129128E+11 | 14336.03 | 0.641452E+10 | 4639.58 | ||
Maximum of Months | 0.162771E+11 | 16279.94 | 0.724851E+10 | 4639.58 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.174880E+10 | 1534.02 | 02-JAN-09:09 | 0.443872E+10 | 2912.71 | 02-JAN-09:09 |
February | 0.159209E+10 | 1534.02 | 01-FEB-09:09 | 0.402701E+10 | 2912.71 | 01-FEB-09:09 |
March | 0.181792E+10 | 1534.02 | 01-MAR-09:09 | 0.455059E+10 | 2912.71 | 01-MAR-09:09 |
April | 0.171453E+10 | 1534.02 | 01-APR-09:09 | 0.432429E+10 | 2912.71 | 01-APR-09:09 |
May | 0.178336E+10 | 1534.02 | 01-MAY-08:09 | 0.449465E+10 | 2912.71 | 01-MAY-08:09 |
June | 0.175416E+10 | 1534.02 | 01-JUN-08:09 | 0.439471E+10 | 2912.71 | 01-JUN-08:09 |
July | 0.174372E+10 | 1534.02 | 01-JUL-09:09 | 0.442423E+10 | 2912.71 | 01-JUL-09:09 |
August | 0.181792E+10 | 1534.02 | 01-AUG-08:09 | 0.455059E+10 | 2912.71 | 01-AUG-08:09 |
September | 0.171453E+10 | 1534.02 | 01-SEP-08:09 | 0.432429E+10 | 2912.71 | 01-SEP-08:09 |
October | 0.174880E+10 | 1534.02 | 02-OCT-08:09 | 0.443872E+10 | 2912.71 | 02-OCT-08:09 |
November | 0.169012E+10 | 1534.02 | 01-NOV-08:09 | 0.429732E+10 | 2912.71 | 01-NOV-08:09 |
December | 0.174372E+10 | 1534.02 | 01-DEC-09:09 | 0.442423E+10 | 2912.71 | 01-DEC-09:09 |
Annual Sum or Average | 0.208697E+11 | 0.526893E+11 | ||||
Minimum of Months | 0.159209E+10 | 1534.02 | 0.402701E+10 | 2912.71 | ||
Maximum of Months | 0.181792E+10 | 1534.02 | 0.455059E+10 | 2912.71 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.169457E+10 | 1485.24 | 02-JAN-09:09 | 0.666220E+09 | 437.18 | 02-JAN-09:09 |
February | 0.154270E+10 | 1485.24 | 01-FEB-09:09 | 0.604426E+09 | 437.18 | 01-FEB-09:09 |
March | 0.176147E+10 | 1485.24 | 01-MAR-09:09 | 0.683011E+09 | 437.18 | 01-MAR-09:09 |
April | 0.166132E+10 | 1485.24 | 01-APR-09:09 | 0.649045E+09 | 437.18 | 01-APR-09:09 |
May | 0.172802E+10 | 1485.24 | 01-MAY-08:09 | 0.674616E+09 | 437.18 | 01-MAY-08:09 |
June | 0.169970E+10 | 1485.24 | 01-JUN-08:09 | 0.659615E+09 | 437.18 | 01-JUN-08:09 |
July | 0.168964E+10 | 1485.24 | 01-JUL-09:09 | 0.664046E+09 | 437.18 | 01-JUL-09:09 |
August | 0.176147E+10 | 1485.24 | 01-AUG-08:09 | 0.683011E+09 | 437.18 | 01-AUG-08:09 |
September | 0.166132E+10 | 1485.24 | 01-SEP-08:09 | 0.649045E+09 | 437.18 | 01-SEP-08:09 |
October | 0.169457E+10 | 1485.24 | 02-OCT-08:09 | 0.666220E+09 | 437.18 | 02-OCT-08:09 |
November | 0.163772E+10 | 1485.24 | 01-NOV-08:09 | 0.644998E+09 | 437.18 | 01-NOV-08:09 |
December | 0.168964E+10 | 1485.24 | 01-DEC-09:09 | 0.664046E+09 | 437.18 | 01-DEC-09:09 |
Annual Sum or Average | 0.202221E+11 | 0.790830E+10 | ||||
Minimum of Months | 0.154270E+10 | 1485.24 | 0.604426E+09 | 437.18 | ||
Maximum of Months | 0.176147E+10 | 1485.24 | 0.683011E+09 | 437.18 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 6919213.84 | 2.58 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 6249612.50 | 2.58 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 6919213.84 | 2.58 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 6696013.39 | 2.58 | 01-APR-00:10 | 0.00 | 0.00 |
May | 6919213.84 | 2.58 | 01-MAY-00:10 | 0.00 | 0.00 |
June | 6696013.39 | 2.58 | 01-JUN-00:10 | 0.00 | 0.00 |
July | 6919213.84 | 2.58 | 01-JUL-00:10 | 0.00 | 0.00 |
August | 6919213.84 | 2.58 | 01-AUG-00:10 | 0.00 | 0.00 |
September | 6696013.39 | 2.58 | 01-SEP-00:10 | 0.00 | 0.00 |
October | 6919213.84 | 2.58 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 6696013.39 | 2.58 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 6919213.84 | 2.58 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 81468162.94 | ||||
Minimum of Months | 6249612.50 | 2.58 | 0.00 | 0.00 | |
Maximum of Months | 6919213.84 | 2.58 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.149153E+10 | 0.419292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2598434.51 | 0.878945E+09 |
February | 0.479114E+10 | 0.135698E+10 | 0.380401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5238358.04 | 0.635711E+09 |
March | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14643853.65 | 0.722301E+09 |
April | 0.518069E+10 | 0.146057E+10 | 0.408483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34362000.00 | 0.268260E+09 |
May | 0.536353E+10 | 0.151892E+10 | 0.424576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178089E+09 | 7079238.71 |
June | 0.528933E+10 | 0.149233E+10 | 0.415135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163266E+09 | 12339875.81 |
July | 0.525489E+10 | 0.148716E+10 | 0.417924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227602E+09 | 754438.65 |
August | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228475E+09 | 14758679.08 |
September | 0.518069E+10 | 0.146057E+10 | 0.408483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176853E+09 | 26285986.52 |
October | 0.524694E+10 | 0.149153E+10 | 0.419292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142194E+09 | 0.227155E+09 |
November | 0.504819E+10 | 0.144192E+10 | 0.405935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14796621.52 | 0.462693E+09 |
December | 0.525489E+10 | 0.148716E+10 | 0.417924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8573183.32 | 0.778535E+09 |
Annual Sum or Average | 0.628175E+11 | 0.177813E+11 | 0.497716E+11 | 0.119669E+10 | 0.403482E+10 | ||||
Minimum of Months | 0.479114E+10 | 0.135698E+10 | 0.380401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2598434.51 | 754438.65 |
Maximum of Months | 0.548013E+10 | 0.154631E+10 | 0.429860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228475E+09 | 0.878945E+09 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.161362E+11 | 0.707031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2121854.34 | 0.774652E+09 |
February | 0.201852E+11 | 0.140486E+11 | 0.641452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4283223.49 | 0.566150E+09 |
March | 0.230879E+11 | 0.151053E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11987046.47 | 0.643941E+09 |
April | 0.218263E+11 | 0.135623E+11 | 0.688804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26404303.35 | 0.251291E+09 |
May | 0.225967E+11 | 0.138567E+11 | 0.715941E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107951E+09 | 37269017.91 |
June | 0.222841E+11 | 0.133760E+11 | 0.700021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102696E+09 | 34372486.09 |
July | 0.221389E+11 | 0.129128E+11 | 0.704724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130774E+09 | 11114180.33 |
August | 0.230879E+11 | 0.134166E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136870E+09 | 46403466.13 |
September | 0.218263E+11 | 0.129930E+11 | 0.688804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108817E+09 | 69627170.39 |
October | 0.221054E+11 | 0.142864E+11 | 0.707031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90341964.69 | 0.247874E+09 |
November | 0.212681E+11 | 0.154249E+11 | 0.684509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11351690.20 | 0.412677E+09 |
December | 0.221389E+11 | 0.162771E+11 | 0.704724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7002548.13 | 0.691714E+09 |
Annual Sum or Average | 0.264651E+12 | 0.171396E+12 | 0.839274E+11 | 0.740601E+09 | 0.378709E+10 | ||||
Minimum of Months | 0.201852E+11 | 0.129128E+11 | 0.641452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2121854.34 | 11114180.33 |
Maximum of Months | 0.230879E+11 | 0.162771E+11 | 0.724851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136870E+09 | 0.774652E+09 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.174880E+10 | 0.443872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1123267.90 | 0.430109E+09 |
February | 0.190200E+10 | 0.159209E+10 | 0.402701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2267521.42 | 0.304111E+09 |
March | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6345658.11 | 0.328163E+09 |
April | 0.205665E+10 | 0.171453E+10 | 0.432429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14910873.10 | 0.118802E+09 |
May | 0.212923E+10 | 0.178336E+10 | 0.449465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 77369837.51 | 2868382.17 |
June | 0.209978E+10 | 0.175416E+10 | 0.439471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 70645410.29 | 5168919.98 |
July | 0.208610E+10 | 0.174372E+10 | 0.442423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98457478.39 | 297340.55 |
August | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98269506.30 | 6325689.16 |
September | 0.205665E+10 | 0.171453E+10 | 0.432429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76149993.98 | 11164900.36 |
October | 0.208295E+10 | 0.174880E+10 | 0.443872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60840265.30 | 99820788.61 |
November | 0.200405E+10 | 0.169012E+10 | 0.429732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6400391.08 | 0.211199E+09 |
December | 0.208610E+10 | 0.174372E+10 | 0.442423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3707336.64 | 0.372890E+09 |
Annual Sum or Average | 0.249375E+11 | 0.208697E+11 | 0.526893E+11 | 0.516488E+09 | 0.189092E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.159209E+10 | 0.402701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1123267.90 | 297340.55 |
Maximum of Months | 0.217552E+10 | 0.181792E+10 | 0.455059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98457478.39 | 0.430109E+09 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.169457E+10 | 0.666220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1123628.12 | 0.409374E+09 |
February | 0.190200E+10 | 0.154270E+10 | 0.604426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2267574.78 | 0.287889E+09 |
March | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6346085.65 | 0.311401E+09 |
April | 0.205665E+10 | 0.166132E+10 | 0.649045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14927920.74 | 0.114536E+09 |
May | 0.212923E+10 | 0.172802E+10 | 0.674616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 77194142.40 | 3046540.70 |
June | 0.209978E+10 | 0.169970E+10 | 0.659615E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 70737131.61 | 5331396.89 |
July | 0.208610E+10 | 0.168964E+10 | 0.664046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 98687340.23 | 321944.56 |
August | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 98827643.44 | 6352384.20 |
September | 0.205665E+10 | 0.166132E+10 | 0.649045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 76453026.81 | 11144458.38 |
October | 0.208295E+10 | 0.169457E+10 | 0.666220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 61108292.48 | 99189506.29 |
November | 0.200405E+10 | 0.163772E+10 | 0.644998E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6411302.09 | 0.209227E+09 |
December | 0.208610E+10 | 0.168964E+10 | 0.664046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3707554.33 | 0.355082E+09 |
Annual Sum or Average | 0.249375E+11 | 0.202221E+11 | 0.790830E+10 | 0.517792E+09 | 0.181290E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.154270E+10 | 0.604426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1123628.12 | 321944.56 |
Maximum of Months | 0.217552E+10 | 0.176147E+10 | 0.683011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 98827643.44 | 0.409374E+09 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129248.10 | 0.166316E+10 |
February | 0.00 | 6249612.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126535.13 | 0.143401E+10 |
March | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9718736.96 | 0.896944E+09 |
April | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76036236.17 | 0.337328E+09 |
May | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381958E+09 | 39707237.77 |
June | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423506E+09 | 20591663.55 |
July | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401803E+09 | 45499281.06 |
August | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346682E+09 | 59838201.02 |
September | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162923E+09 | 0.128703E+09 |
October | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51981884.05 | 0.321945E+09 |
November | 0.00 | 6696013.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5148929.71 | 0.940425E+09 |
December | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1548140.92 | 0.154922E+10 |
Annual Sum or Average | 0.00 | 81468162.94 | 0.186156E+10 | 0.743737E+10 | |||||
Minimum of Months | 0.00 | 6249612.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126535.13 | 20591663.55 |
Maximum of Months | 0.00 | 6919213.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423506E+09 | 0.166316E+10 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 1249.73 | 02-JAN-09:09 | 2751.42 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 54.80 | 19-JAN-12:03 | 1871.37 | 21-JAN-06:00 |
February | 5888.82 | 01-FEB-15:09 | 1249.73 | 01-FEB-09:09 | 2751.42 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 144.86 | 02-FEB-13:00 | 2846.82 | 05-FEB-08:00 |
March | 5888.82 | 01-MAR-15:09 | 1249.73 | 01-MAR-09:09 | 2751.42 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 144.37 | 28-MAR-14:00 | 2216.46 | 20-MAR-22:00 |
April | 5888.82 | 01-APR-10:09 | 1249.73 | 01-APR-09:09 | 2751.42 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 233.42 | 29-APR-16:00 | 1266.33 | 01-APR-21:10 |
May | 5888.82 | 01-MAY-14:09 | 1249.73 | 01-MAY-08:09 | 2751.42 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 492.41 | 07-MAY-18:03 | 119.41 | 13-MAY-04:55 |
June | 5888.82 | 01-JUN-14:09 | 1249.73 | 01-JUN-08:09 | 2751.42 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 506.26 | 09-JUN-20:10 | 296.65 | 06-JUN-20:55 |
July | 5888.82 | 01-JUL-10:09 | 1249.73 | 01-JUL-09:09 | 2751.42 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 545.65 | 02-JUL-21:10 | 81.67 | 11-JUL-20:10 |
August | 5888.82 | 01-AUG-14:09 | 1249.73 | 01-AUG-08:09 | 2751.42 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 805.19 | 22-AUG-20:10 | 404.19 | 25-AUG-24:00 |
September | 5888.82 | 01-SEP-14:09 | 1249.73 | 01-SEP-08:09 | 2751.42 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1063.69 | 09-SEP-22:53 | 290.56 | 05-SEP-02:55 |
October | 5888.82 | 02-OCT-14:09 | 1249.73 | 02-OCT-08:09 | 2751.42 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 479.58 | 08-OCT-18:20 | 1106.14 | 29-OCT-02:00 |
November | 5888.82 | 01-NOV-14:09 | 1249.73 | 01-NOV-08:09 | 2751.42 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 117.53 | 07-NOV-22:10 | 1576.88 | 12-NOV-07:00 |
December | 5888.82 | 01-DEC-15:09 | 1249.73 | 01-DEC-09:09 | 2751.42 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 105.02 | 13-DEC-14:00 | 2247.42 | 20-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 1249.73 | 2751.42 | 0.00 | 0.00 | 0.00 | 0.00 | 54.80 | 81.67 | |||||
Maximum of Months | 5888.82 | 1249.73 | 2751.42 | 0.00 | 0.00 | 0.00 | 0.00 | 1063.69 | 2846.82 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 16279.94 | 02-JAN-17:49 | 4639.58 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 44.85 | 19-JAN-12:03 | 1641.04 | 21-JAN-06:00 |
February | 24809.68 | 01-FEB-15:09 | 16030.10 | 04-FEB-17:00 | 4639.58 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 118.58 | 02-FEB-13:00 | 2301.38 | 05-FEB-08:00 |
March | 24809.68 | 01-MAR-15:09 | 15979.19 | 02-MAR-17:00 | 4639.58 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 118.17 | 28-MAR-14:00 | 2001.41 | 20-MAR-22:00 |
April | 24809.68 | 01-APR-10:09 | 14820.70 | 14-APR-08:09 | 4639.58 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 191.06 | 29-APR-16:00 | 1058.51 | 02-APR-06:00 |
May | 24809.68 | 01-MAY-14:09 | 14534.62 | 11-MAY-16:00 | 4639.58 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 404.59 | 07-MAY-18:03 | 176.93 | 05-MAY-03:55 |
June | 24809.68 | 01-JUN-14:09 | 14548.53 | 20-JUN-16:30 | 4639.58 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 400.08 | 09-JUN-20:03 | 345.27 | 06-JUN-21:10 |
July | 24809.68 | 01-JUL-10:09 | 14336.03 | 27-JUL-16:00 | 4639.58 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 421.85 | 04-JUL-18:03 | 132.61 | 31-JUL-02:55 |
August | 24809.68 | 01-AUG-14:09 | 14679.60 | 30-AUG-16:00 | 4639.58 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 643.90 | 22-AUG-20:03 | 483.62 | 25-AUG-23:55 |
September | 24809.68 | 01-SEP-14:09 | 15369.23 | 30-SEP-16:00 | 4639.58 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 718.54 | 09-SEP-22:53 | 378.16 | 05-SEP-02:55 |
October | 24809.68 | 02-OCT-14:09 | 15756.37 | 21-OCT-16:00 | 4639.58 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 389.83 | 08-OCT-18:03 | 989.76 | 29-OCT-02:00 |
November | 24809.68 | 01-NOV-14:09 | 16279.94 | 06-NOV-17:40 | 4639.58 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 92.00 | 07-NOV-13:00 | 1369.51 | 12-NOV-07:00 |
December | 24809.68 | 01-DEC-15:09 | 16279.94 | 01-DEC-17:40 | 4639.58 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 85.97 | 13-DEC-14:00 | 2092.25 | 20-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 14336.03 | 4639.58 | 0.00 | 0.00 | 0.00 | 0.00 | 44.85 | 132.61 | |||||
Maximum of Months | 24809.68 | 16279.94 | 4639.58 | 0.00 | 0.00 | 0.00 | 0.00 | 718.54 | 2301.38 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1534.02 | 02-JAN-09:09 | 2912.71 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.74 | 19-JAN-12:03 | 864.87 | 26-JAN-03:00 |
February | 2337.76 | 01-FEB-15:09 | 1534.02 | 01-FEB-09:09 | 2912.71 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 62.78 | 02-FEB-13:00 | 1233.60 | 05-FEB-08:00 |
March | 2337.76 | 01-MAR-15:09 | 1534.02 | 01-MAR-09:09 | 2912.71 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 62.55 | 28-MAR-14:00 | 1000.07 | 20-MAR-22:00 |
April | 2337.76 | 01-APR-10:09 | 1534.02 | 01-APR-09:09 | 2912.71 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 101.15 | 29-APR-16:00 | 562.77 | 01-APR-21:10 |
May | 2337.76 | 01-MAY-14:09 | 1534.02 | 01-MAY-08:09 | 2912.71 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 216.98 | 07-MAY-18:10 | 51.96 | 13-MAY-04:45 |
June | 2337.76 | 01-JUN-14:09 | 1534.02 | 01-JUN-08:09 | 2912.71 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 217.63 | 09-JUN-20:10 | 130.97 | 06-JUN-20:10 |
July | 2337.76 | 01-JUL-10:09 | 1534.02 | 01-JUL-09:09 | 2912.71 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 236.45 | 02-JUL-21:10 | 40.38 | 11-JUL-20:10 |
August | 2337.76 | 01-AUG-14:09 | 1534.02 | 01-AUG-08:09 | 2912.71 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 346.32 | 22-AUG-20:10 | 204.76 | 25-AUG-24:00 |
September | 2337.76 | 01-SEP-14:09 | 1534.02 | 01-SEP-08:09 | 2912.71 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 455.78 | 09-SEP-22:53 | 121.76 | 12-SEP-24:00 |
October | 2337.76 | 02-OCT-14:09 | 1534.02 | 02-OCT-08:09 | 2912.71 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 215.45 | 08-OCT-18:10 | 528.24 | 29-OCT-02:00 |
November | 2337.76 | 01-NOV-14:09 | 1534.02 | 01-NOV-08:09 | 2912.71 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 60.52 | 07-NOV-21:47 | 723.16 | 12-NOV-08:00 |
December | 2337.76 | 01-DEC-15:09 | 1534.02 | 01-DEC-09:09 | 2912.71 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.51 | 13-DEC-14:00 | 1057.98 | 20-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1534.02 | 2912.71 | 0.00 | 0.00 | 0.00 | 0.00 | 23.74 | 40.38 | |||||
Maximum of Months | 2337.76 | 1534.02 | 2912.71 | 0.00 | 0.00 | 0.00 | 0.00 | 455.78 | 1233.60 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1485.24 | 02-JAN-09:09 | 437.18 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.75 | 19-JAN-12:03 | 813.68 | 26-JAN-03:00 |
February | 2337.76 | 01-FEB-15:09 | 1485.24 | 01-FEB-09:09 | 437.18 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 62.78 | 02-FEB-13:00 | 1235.84 | 05-FEB-07:47 |
March | 2337.76 | 01-MAR-15:09 | 1485.24 | 01-MAR-09:09 | 437.18 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 62.55 | 28-MAR-14:00 | 942.49 | 20-MAR-22:00 |
April | 2337.76 | 01-APR-10:09 | 1485.24 | 01-APR-09:09 | 437.18 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 101.15 | 29-APR-16:00 | 520.53 | 01-APR-21:10 |
May | 2337.76 | 01-MAY-14:09 | 1485.24 | 01-MAY-08:09 | 437.18 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 217.54 | 07-MAY-18:10 | 48.09 | 13-MAY-04:45 |
June | 2337.76 | 01-JUN-14:09 | 1485.24 | 01-JUN-08:09 | 437.18 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 219.00 | 09-JUN-20:10 | 130.75 | 06-JUN-20:55 |
July | 2337.76 | 01-JUL-10:09 | 1485.24 | 01-JUL-09:09 | 437.18 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 236.58 | 02-JUL-21:10 | 36.38 | 11-JUL-20:10 |
August | 2337.76 | 01-AUG-14:09 | 1485.24 | 01-AUG-08:09 | 437.18 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 347.39 | 22-AUG-20:10 | 175.19 | 25-AUG-24:00 |
September | 2337.76 | 01-SEP-14:09 | 1485.24 | 01-SEP-08:09 | 437.18 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 457.78 | 09-SEP-22:53 | 123.28 | 05-SEP-03:25 |
October | 2337.76 | 02-OCT-14:09 | 1485.24 | 02-OCT-08:09 | 437.18 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 215.35 | 08-OCT-18:10 | 508.71 | 29-OCT-02:00 |
November | 2337.76 | 01-NOV-14:09 | 1485.24 | 01-NOV-08:09 | 437.18 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 55.14 | 07-NOV-21:47 | 707.52 | 12-NOV-08:00 |
December | 2337.76 | 01-DEC-15:09 | 1485.24 | 01-DEC-09:09 | 437.18 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.51 | 13-DEC-14:00 | 973.33 | 20-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1485.24 | 437.18 | 0.00 | 0.00 | 0.00 | 0.00 | 23.75 | 36.38 | |||||
Maximum of Months | 2337.76 | 1485.24 | 437.18 | 0.00 | 0.00 | 0.00 | 0.00 | 457.78 | 1235.84 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 2.58 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.82 | 02-JAN-15:00 | 18219.65 | 04-JAN-18:00 |
February | 0.00 | 01-FEB-00:10 | 2.58 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.10 | 24-FEB-12:55 | 20305.56 | 04-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 2.58 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 411.28 | 30-MAR-13:00 | 17685.64 | 11-MAR-12:10 |
April | 0.00 | 01-APR-00:10 | 2.58 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1275.59 | 28-APR-11:02 | 2203.88 | 11-APR-07:01 |
May | 0.00 | 01-MAY-00:10 | 2.58 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1945.68 | 27-MAY-11:02 | 1156.39 | 13-MAY-11:53 |
June | 0.00 | 01-JUN-00:10 | 2.58 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1966.78 | 14-JUN-11:02 | 1403.69 | 18-JUN-13:53 |
July | 0.00 | 01-JUL-00:10 | 2.58 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2770.36 | 18-JUL-11:01 | 1256.17 | 31-JUL-11:02 |
August | 0.00 | 01-AUG-00:10 | 2.58 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1947.28 | 01-AUG-11:02 | 1564.75 | 06-AUG-15:53 |
September | 0.00 | 01-SEP-00:10 | 2.58 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1973.45 | 10-SEP-11:02 | 2471.25 | 02-SEP-15:52 |
October | 0.00 | 01-OCT-00:10 | 2.58 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 812.19 | 06-OCT-11:03 | 3744.17 | 27-OCT-11:01 |
November | 0.00 | 01-NOV-00:10 | 2.58 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 361.33 | 28-NOV-12:05 | 6685.72 | 12-NOV-12:01 |
December | 0.00 | 01-DEC-00:10 | 2.58 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 305.76 | 13-DEC-12:05 | 22022.20 | 20-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.82 | 1156.39 | ||||
Maximum of Months | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2770.36 | 22022.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18086.99 | 01-JAN-20:50 | 0.00 | 163.56 | 907.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.67 |
February | 17469.73 | 24-FEB-22:05 | 0.00 | 163.56 | 1210.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.59 |
March | 17310.37 | 28-MAR-21:25 | 0.00 | 163.56 | 1210.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 493.57 |
April | 29286.10 | 18-APR-20:32 | 0.00 | 490.69 | 3630.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.87 |
May | 25430.45 | 07-MAY-18:13 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 454.06 | 0.00 |
June | 24687.29 | 28-JUN-20:10 | 0.00 | 1065.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 397.49 | 0.00 |
July | 27058.32 | 07-JUL-21:23 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 220.80 | 0.00 |
August | 28071.40 | 02-AUG-22:03 | 0.00 | 245.35 | 1815.26 | 0.00 | 0.00 | 0.00 | 0.00 | 265.49 | 0.00 |
September | 27989.58 | 10-SEP-22:03 | 0.00 | 245.35 | 1361.45 | 0.00 | 0.00 | 0.00 | 0.00 | 163.51 | 0.00 |
October | 39206.51 | 26-OCT-20:17 | 0.00 | 654.26 | 4840.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.95 |
November | 23727.38 | 08-NOV-05:22 | 0.00 | 408.91 | 3025.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 524.98 |
December | 29981.31 | 17-DEC-08:61 | 0.00 | 654.26 | 3630.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.45 |
Annual Sum or Average | |||||||||||
Minimum of Months | 17310.37 | 0.00 | 163.56 | 907.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39206.51 | 0.00 | 1065.35 | 4840.70 | 0.00 | 0.00 | 0.00 | 0.00 | 454.06 | 524.98 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 130591.66 | 02-JAN-07:03 | 12404.84 | 1378.20 | 8248.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.34 |
February | 131649.57 | 25-FEB-07:03 | 12404.84 | 1378.20 | 6186.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 136964.08 | 01-MAR-07:03 | 12404.84 | 1378.20 | 8248.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.84 |
April | 137817.22 | 18-APR-06:03 | 12404.84 | 1378.20 | 8248.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.04 |
May | 107661.43 | 12-MAY-06:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.30 |
June | 108278.83 | 12-JUN-06:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.63 |
July | 94984.08 | 18-JUL-06:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.04 |
August | 101322.88 | 04-AUG-06:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 9.84 | 0.00 |
September | 107011.62 | 23-SEP-06:02 | 15506.05 | 1722.75 | 7732.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.16 |
October | 195031.19 | 27-OCT-06:02 | 15506.05 | 1722.75 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.15 |
November | 131881.82 | 30-NOV-07:03 | 12404.84 | 1378.20 | 8248.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.22 |
December | 137258.72 | 17-DEC-09:02 | 18607.26 | 2067.29 | 9279.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 167.17 |
Annual Sum or Average | |||||||||||
Minimum of Months | 94984.08 | 12404.84 | 1378.20 | 6186.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 195031.19 | 18607.26 | 2067.29 | 10310.18 | 0.00 | 0.00 | 0.00 | 0.00 | 9.84 | 212.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 15913.56 | 01-JAN-08:61 | 0.00 | 324.66 | 4804.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.23 |
February | 17464.44 | 01-FEB-23:01 | 0.00 | 227.26 | 4483.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.78 |
March | 18524.26 | 25-MAR-23:41 | 0.00 | 259.73 | 3843.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.66 |
April | 15316.19 | 30-APR-20:31 | 0.00 | 227.26 | 3362.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.18 |
May | 13811.26 | 07-MAY-18:43 | 0.00 | 97.40 | 1441.26 | 0.00 | 0.00 | 0.00 | 0.00 | 112.03 | 0.00 |
June | 14193.21 | 28-JUN-20:10 | 0.00 | 1022.68 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 171.03 | 0.00 |
July | 16563.77 | 07-JUL-21:23 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 97.47 | 0.00 |
August | 17848.99 | 30-AUG-21:23 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 17703.88 | 10-SEP-22:03 | 0.00 | 97.40 | 1441.26 | 0.00 | 0.00 | 0.00 | 0.00 | 70.45 | 0.00 |
October | 18135.65 | 05-OCT-23:23 | 0.00 | 97.40 | 1921.68 | 0.00 | 0.00 | 0.00 | 0.00 | 42.86 | 0.00 |
November | 17301.19 | 22-NOV-21:15 | 0.00 | 64.93 | 1281.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.38 |
December | 16695.04 | 03-DEC-08:61 | 0.00 | 324.66 | 4804.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.08 |
Annual Sum or Average | |||||||||||
Minimum of Months | 13811.26 | 0.00 | 64.93 | 1281.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18524.26 | 0.00 | 1022.68 | 4804.19 | 0.00 | 0.00 | 0.00 | 0.00 | 171.03 | 74.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12135.66 | 16-JAN-22:32 | 0.00 | 194.80 | 432.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.48 |
February | 11984.17 | 01-FEB-23:01 | 0.00 | 227.26 | 673.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.43 |
March | 15400.59 | 24-MAR-20:20 | 0.00 | 259.73 | 769.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 102.29 |
April | 14859.42 | 17-APR-20:41 | 0.00 | 259.73 | 769.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11869.88 | 07-MAY-18:43 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 112.67 | 0.00 |
June | 11289.44 | 28-JUN-20:10 | 0.00 | 1022.68 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 172.00 | 0.00 |
July | 13092.65 | 07-JUL-21:23 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 97.02 | 0.00 |
August | 14297.71 | 30-AUG-22:03 | 0.00 | 97.40 | 288.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 14559.90 | 10-SEP-22:43 | 0.00 | 97.40 | 216.32 | 0.00 | 0.00 | 0.00 | 0.00 | 45.64 | 0.00 |
October | 16245.88 | 26-OCT-21:26 | 0.00 | 259.73 | 769.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.57 |
November | 13827.43 | 22-NOV-21:20 | 0.00 | 64.93 | 192.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.07 |
December | 15765.03 | 17-DEC-20:01 | 0.00 | 292.19 | 648.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 384.15 |
Annual Sum or Average | |||||||||||
Minimum of Months | 11289.44 | 0.00 | 64.93 | 192.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16245.88 | 0.00 | 1022.68 | 769.15 | 0.00 | 0.00 | 0.00 | 0.00 | 172.00 | 384.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.24 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.49 |
March | 0.00 | 01-MAR-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.69 |
April | 0.00 | 01-APR-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.85 |
June | 0.00 | 01-JUN-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.02 |
July | 0.00 | 01-JUL-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.77 |
August | 0.00 | 01-AUG-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 |
September | 0.00 | 01-SEP-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.76 |
October | 0.00 | 01-OCT-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.72 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.44 |
December | 0.00 | 01-DEC-00:05 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.75 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.76 | |
Maximum of Months | 0.00 | 0.00 | 5.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.24 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.572790E+11 | 63680.18 | 19-JAN-15:09 | 0.120979E+11 | 76317.26 | 05-JAN-07:19 |
February | 0.543090E+11 | 61907.57 | 24-FEB-15:00 | 0.105159E+11 | 86749.53 | 05-FEB-09:20 |
March | 0.629737E+11 | 62568.34 | 06-MAR-15:00 | 0.990147E+10 | 59243.92 | 13-MAR-06:19 |
April | 0.703995E+11 | 76909.34 | 28-APR-15:00 | 0.723696E+10 | 4880.16 | 03-APR-11:50 |
May | 0.956328E+11 | 77819.94 | 27-MAY-15:30 | 0.733582E+10 | 4846.41 | 01-MAY-11:50 |
June | 0.978823E+11 | 84414.17 | 28-JUN-14:09 | 0.701038E+10 | 4812.42 | 01-JUN-11:09 |
July | 0.102942E+12 | 89776.37 | 22-JUL-15:00 | 0.713559E+10 | 4790.09 | 03-JUL-11:00 |
August | 0.103595E+12 | 83153.49 | 03-AUG-15:00 | 0.720838E+10 | 4799.09 | 31-AUG-11:39 |
September | 0.943277E+11 | 87433.92 | 09-SEP-16:00 | 0.703154E+10 | 4825.90 | 29-SEP-11:00 |
October | 0.898221E+11 | 85628.30 | 07-OCT-12:00 | 0.737316E+10 | 4864.39 | 31-OCT-11:39 |
November | 0.668921E+11 | 73926.76 | 02-NOV-14:39 | 0.726346E+10 | 4898.41 | 30-NOV-12:50 |
December | 0.627796E+11 | 67731.69 | 15-DEC-15:09 | 0.105078E+11 | 77499.18 | 21-DEC-07:19 |
Annual Sum or Average | 0.958836E+12 | 0.100618E+12 | ||||
Minimum of Months | 0.543090E+11 | 61907.57 | 0.701038E+10 | 4790.09 | ||
Maximum of Months | 0.103595E+12 | 89776.37 | 0.120979E+11 | 86749.53 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.210780E+11 | 0.385459E+10 | 0.163682E+11 | 0.00 | 0.101975E+11 | 0.00 | 0.00 | 0.578072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.185466E+11 | 0.328027E+10 | 0.148500E+11 | 0.00 | 0.925976E+10 | 0.00 | 0.00 | 0.837237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.202379E+11 | 0.332868E+10 | 0.167807E+11 | 0.00 | 0.102902E+11 | 0.00 | 0.00 | 0.123362E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.184054E+11 | 0.292755E+10 | 0.159462E+11 | 0.00 | 0.992571E+10 | 0.00 | 0.00 | 0.231947E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.188939E+11 | 0.276030E+10 | 0.165744E+11 | 0.00 | 0.107966E+11 | 0.00 | 0.00 | 0.466075E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.183289E+11 | 0.252705E+10 | 0.162059E+11 | 0.00 | 0.110068E+11 | 0.00 | 0.00 | 0.498137E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.178402E+11 | 0.268748E+10 | 0.163148E+11 | 0.00 | 0.117736E+11 | 0.00 | 0.00 | 0.543263E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.185492E+11 | 0.290189E+10 | 0.167807E+11 | 0.00 | 0.117258E+11 | 0.00 | 0.00 | 0.536377E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.178361E+11 | 0.309746E+10 | 0.159462E+11 | 0.00 | 0.108382E+11 | 0.00 | 0.00 | 0.466098E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.192282E+11 | 0.350870E+10 | 0.163682E+11 | 0.00 | 0.109906E+11 | 0.00 | 0.00 | 0.397265E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.202013E+11 | 0.365169E+10 | 0.158468E+11 | 0.00 | 0.983914E+10 | 0.00 | 0.00 | 0.173532E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212045E+11 | 0.392134E+10 | 0.163148E+11 | 0.00 | 0.102401E+11 | 0.00 | 0.00 | 0.110988E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230350E+12 | 0.384470E+11 | 0.194297E+12 | 0.126884E+12 | 0.00 | 0.368858E+12 | |||||||
Minimum of Months | 0.178361E+11 | 0.252705E+10 | 0.148500E+11 | 0.00 | 0.925976E+10 | 0.00 | 0.00 | 0.578072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.212045E+11 | 0.392134E+10 | 0.167807E+11 | 0.00 | 0.117736E+11 | 0.00 | 0.00 | 0.543263E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.439866E+10 | 0.00 | 0.769923E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.356558E+10 | 0.00 | 0.695031E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.224369E+10 | 0.00 | 0.765778E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.723696E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.733582E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.701038E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.713559E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.720838E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.703154E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.737316E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.726346E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.286639E+10 | 0.00 | 0.764137E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.130743E+11 | 0.875440E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.695031E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.439866E+10 | 0.00 | 0.769923E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 20551.52 | 02-JAN-17:49 | 3371.20 | 01-JAN-06:10 | 10740.89 | 02-JAN-09:09 | 0.00 | 8490.98 | 05-JAN-08:20 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 20301.68 | 04-FEB-17:00 | 3371.20 | 01-FEB-06:10 | 10740.89 | 01-FEB-09:09 | 0.00 | 9237.68 | 05-FEB-09:20 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 20250.76 | 02-MAR-17:00 | 3371.20 | 01-MAR-06:10 | 10740.89 | 01-MAR-09:09 | 0.00 | 8975.55 | 07-MAR-07:10 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 19092.28 | 14-APR-08:09 | 3371.20 | 01-APR-05:10 | 10740.89 | 01-APR-09:09 | 0.00 | 8975.55 | 28-APR-06:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 18806.20 | 11-MAY-16:00 | 3371.20 | 01-MAY-05:10 | 10740.89 | 01-MAY-08:09 | 0.00 | 9420.40 | 24-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 18820.11 | 20-JUN-16:30 | 3371.20 | 01-JUN-05:10 | 10740.89 | 01-JUN-08:09 | 0.00 | 9716.52 | 28-JUN-14:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 18607.60 | 27-JUL-16:00 | 3371.20 | 01-JUL-05:10 | 10740.89 | 01-JUL-09:09 | 0.00 | 10428.12 | 22-JUL-15:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 18951.17 | 30-AUG-16:00 | 3371.20 | 01-AUG-05:10 | 10740.89 | 01-AUG-08:09 | 0.00 | 10351.86 | 06-AUG-08:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 19640.80 | 30-SEP-16:00 | 3371.20 | 01-SEP-05:10 | 10740.89 | 01-SEP-08:09 | 0.00 | 10351.86 | 10-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 20027.95 | 21-OCT-16:00 | 3371.20 | 01-OCT-05:10 | 10740.89 | 02-OCT-08:09 | 0.00 | 10248.80 | 07-OCT-12:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 20551.52 | 06-NOV-17:40 | 3371.20 | 01-NOV-05:10 | 10740.89 | 01-NOV-08:09 | 0.00 | 8975.55 | 02-NOV-06:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 20551.52 | 01-DEC-17:40 | 3371.20 | 01-DEC-06:10 | 10740.89 | 01-DEC-09:09 | 0.00 | 8975.55 | 15-DEC-07:10 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 18607.60 | 3371.20 | 10740.89 | 0.00 | 8490.98 | 0.00 | 0.00 | |||||
Maximum of Months | 20551.52 | 3371.20 | 10740.89 | 0.00 | 10428.12 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 27683.58 | 19-JAN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 27881.43 | 24-FEB-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 29532.85 | 30-MAR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 40797.19 | 28-APR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 41889.69 | 30-MAY-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 48428.27 | 28-JUN-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 52736.02 | 22-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 47537.66 | 03-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 49915.82 | 10-SEP-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 50175.90 | 07-OCT-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 38048.44 | 02-NOV-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 32570.91 | 16-DEC-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 27683.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 52736.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 63680.18 | 19-JAN-15:09 | 18759.06 | 10740.89 | 0.00 | 0.00 | 6496.66 | 0.00 | 0.00 | 27683.58 | 0.00 |
February | 61907.57 | 24-FEB-15:00 | 18177.01 | 10740.89 | 0.00 | 0.00 | 6299.69 | 0.00 | 0.00 | 26689.97 | 0.00 |
March | 62568.34 | 06-MAR-15:00 | 18422.38 | 10740.89 | 0.00 | 0.00 | 6222.92 | 0.00 | 0.00 | 27182.15 | 0.00 |
April | 76909.34 | 28-APR-15:00 | 17440.36 | 10740.89 | 0.00 | 0.00 | 7930.90 | 0.00 | 0.00 | 40797.19 | 0.00 |
May | 77819.94 | 27-MAY-15:30 | 17355.23 | 10740.89 | 0.00 | 0.00 | 8111.69 | 0.00 | 0.00 | 41612.13 | 0.00 |
June | 84414.17 | 28-JUN-14:09 | 15528.49 | 10740.89 | 0.00 | 0.00 | 9716.52 | 0.00 | 0.00 | 48428.27 | 0.00 |
July | 89776.37 | 22-JUL-15:00 | 15871.35 | 10740.89 | 0.00 | 0.00 | 10428.12 | 0.00 | 0.00 | 52736.02 | 0.00 |
August | 83153.49 | 03-AUG-15:00 | 16619.05 | 10740.89 | 0.00 | 0.00 | 8989.16 | 0.00 | 0.00 | 46804.38 | 0.00 |
September | 87433.92 | 09-SEP-16:00 | 18550.16 | 10740.89 | 0.00 | 0.00 | 9341.07 | 0.00 | 0.00 | 48801.81 | 0.00 |
October | 85628.30 | 07-OCT-12:00 | 14462.72 | 10740.89 | 0.00 | 0.00 | 10248.80 | 0.00 | 0.00 | 50175.90 | 0.00 |
November | 73926.76 | 02-NOV-14:39 | 17845.26 | 10740.89 | 0.00 | 0.00 | 7463.63 | 0.00 | 0.00 | 37876.98 | 0.00 |
December | 67731.69 | 15-DEC-15:09 | 18800.89 | 10740.89 | 0.00 | 0.00 | 6528.70 | 0.00 | 0.00 | 31661.22 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 61907.57 | 14462.72 | 10740.89 | 0.00 | 0.00 | 6222.92 | 0.00 | 0.00 | 26689.97 | 0.00 | |
Maximum of Months | 89776.37 | 18800.89 | 10740.89 | 0.00 | 0.00 | 10428.12 | 0.00 | 0.00 | 52736.02 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 74457.26 | 05-JAN-07:19 | 0.00 | 4930.30 | 23-JAN-12:00 | 0.00 |
February | 0.00 | 0.00 | 82222.71 | 05-FEB-09:20 | 0.00 | 4929.49 | 06-FEB-12:30 | 0.00 |
March | 0.00 | 0.00 | 57383.92 | 13-MAR-06:19 | 0.00 | 4913.18 | 01-MAR-12:20 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 4880.16 | 03-APR-11:50 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 4846.41 | 01-MAY-11:50 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4812.42 | 01-JUN-11:09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4790.09 | 03-JUL-11:00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4799.09 | 31-AUG-11:39 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 4825.90 | 29-SEP-11:00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 4864.39 | 31-OCT-11:39 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 4898.41 | 30-NOV-12:50 | 0.00 |
December | 0.00 | 0.00 | 75639.18 | 21-DEC-07:19 | 0.00 | 4922.42 | 29-DEC-12:00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4790.09 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 82222.71 | 0.00 | 4930.30 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 20.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.83 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.49 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 24.51 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.46 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 24.48 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.47 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.48 | 0.00 | 0.00 |
December | 0.17 | 20.54 | 0.00 | 0.00 | 0.67 | 24.49 | 0.00 | 0.00 |
Annual Sum or Average | 1.33 | 20.48 | 0.00 | 10.17 | 24.48 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 20.54 | 0.00 | 0.00 | 2.00 | 24.51 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 24.49 | 0.00 | 0.00 |
February | 0.17 | 20.49 | 0.00 | 0.00 | 4.33 | 24.49 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 24.50 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 24.48 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 24.50 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 15.50 | 24.51 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 28.33 | 24.53 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 39.00 | 24.55 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 30.67 | 24.56 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 39.33 | 24.58 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 13.17 | 24.53 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 24.50 | 0.00 | 0.00 |
Annual Sum or Average | 0.17 | 20.49 | 0.00 | 201.83 | 24.54 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 24.48 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.49 | 0.00 | 0.00 | 39.33 | 24.58 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 20.50 | 0.00 | 0.00 | 1.00 | 24.48 | 0.00 | 0.00 |
February | 0.17 | 20.28 | 0.00 | 0.00 | 1.17 | 24.47 | 0.00 | 0.00 |
March | 0.17 | 20.36 | 0.00 | 0.00 | 1.17 | 24.48 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.47 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.49 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.47 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 11.17 | 24.53 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 18.17 | 24.53 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 24.48 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.48 | 0.00 | 0.00 |
Annual Sum or Average | 0.50 | 20.38 | 0.00 | 58.00 | 24.51 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.47 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.50 | 0.00 | 0.00 | 18.17 | 24.53 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 89.33 | 13.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 50.83 | 13.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 45.33 | 13.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6.17 | 14.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 49.50 | 12.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 241.17 | 13.52 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 89.33 | 14.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 345.00 | 22.55 | 94.00 | 23.34 | 54.83 | 22.96 |
February | 258.00 | 22.79 | 165.00 | 23.42 | 87.00 | 23.00 |
March | 258.50 | 23.03 | 123.67 | 23.71 | 27.00 | 23.05 |
April | 96.33 | 23.71 | 235.17 | 23.89 | 17.33 | 23.89 |
May | 9.33 | 23.89 | 396.00 | 23.89 | 9.33 | 23.89 |
June | 0.00 | 0.00 | 381.67 | 23.89 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 400.17 | 23.89 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 408.67 | 23.89 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 389.17 | 23.89 | 0.00 | 0.00 |
October | 39.33 | 23.76 | 312.00 | 23.89 | 2.50 | 23.89 |
November | 173.00 | 23.58 | 136.17 | 23.89 | 10.00 | 23.89 |
December | 270.50 | 22.78 | 114.00 | 23.76 | 23.33 | 23.26 |
Annual Sum or Average | 1450.00 | 22.96 | 3155.67 | 23.84 | 231.33 | 23.17 |
Minimum of Months | 0.00 | 0.00 | 94.00 | 23.34 | 0.00 | 0.00 |
Maximum of Months | 345.00 | 23.89 | 408.67 | 23.89 | 87.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 320.83 | 22.54 | 103.67 | 23.79 | 39.00 | 23.64 |
February | 224.00 | 22.78 | 175.67 | 23.80 | 49.50 | 23.62 |
March | 189.33 | 22.79 | 170.17 | 23.88 | 17.33 | 23.88 |
April | 60.33 | 23.64 | 296.17 | 23.89 | 30.00 | 23.89 |
May | 51.50 | 23.90 | 418.00 | 23.89 | 51.50 | 23.90 |
June | 36.17 | 23.90 | 408.00 | 23.89 | 36.17 | 23.90 |
July | 91.50 | 23.90 | 415.00 | 23.89 | 91.50 | 23.90 |
August | 75.50 | 23.90 | 422.00 | 23.89 | 75.50 | 23.90 |
September | 93.33 | 23.90 | 405.00 | 23.89 | 93.33 | 23.90 |
October | 79.83 | 23.80 | 347.00 | 23.89 | 65.17 | 23.90 |
November | 126.33 | 23.43 | 186.50 | 23.89 | 33.33 | 23.89 |
December | 261.00 | 22.75 | 147.00 | 23.87 | 40.33 | 23.84 |
Annual Sum or Average | 1609.67 | 23.10 | 3494.17 | 23.88 | 622.67 | 23.85 |
Minimum of Months | 36.17 | 22.54 | 103.67 | 23.79 | 17.33 | 23.62 |
Maximum of Months | 320.83 | 23.90 | 422.00 | 23.89 | 93.33 | 23.90 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 141.67 | 22.93 | 149.33 | 23.87 | 10.50 | 23.64 |
February | 123.83 | 23.00 | 197.33 | 23.84 | 17.50 | 23.33 |
March | 141.50 | 22.94 | 189.00 | 23.86 | 3.67 | 22.37 |
April | 35.67 | 23.55 | 278.00 | 23.89 | 1.50 | 23.89 |
May | 1.83 | 23.89 | 402.50 | 23.89 | 1.83 | 23.89 |
June | 0.00 | 0.00 | 390.00 | 23.89 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 404.50 | 23.89 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 412.67 | 23.89 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 393.33 | 23.89 | 0.00 | 0.00 |
October | 7.33 | 23.50 | 362.17 | 23.89 | 0.00 | 0.00 |
November | 25.67 | 23.48 | 277.67 | 23.89 | 0.00 | 0.00 |
December | 116.67 | 23.06 | 211.83 | 23.87 | 11.00 | 23.47 |
Annual Sum or Average | 594.17 | 23.04 | 3668.33 | 23.88 | 46.00 | 23.40 |
Minimum of Months | 0.00 | 0.00 | 149.33 | 23.84 | 0.00 | 0.00 |
Maximum of Months | 141.67 | 23.89 | 412.67 | 23.89 | 17.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 212.67 | 22.53 | 127.83 | 23.77 | 22.00 | 23.17 |
February | 169.83 | 22.62 | 176.17 | 23.76 | 29.33 | 23.14 |
March | 198.50 | 22.54 | 171.00 | 23.73 | 22.33 | 22.65 |
April | 103.33 | 23.46 | 260.00 | 23.89 | 36.17 | 23.88 |
May | 32.33 | 23.89 | 403.33 | 23.89 | 32.33 | 23.89 |
June | 9.67 | 23.89 | 389.33 | 23.89 | 9.67 | 23.89 |
July | 28.50 | 23.89 | 403.17 | 23.89 | 28.50 | 23.89 |
August | 14.50 | 23.89 | 410.17 | 23.89 | 14.50 | 23.89 |
September | 18.67 | 23.89 | 392.83 | 23.89 | 18.67 | 23.89 |
October | 27.00 | 23.52 | 353.67 | 23.89 | 8.33 | 23.89 |
November | 50.67 | 23.20 | 252.67 | 23.89 | 4.33 | 23.89 |
December | 162.83 | 22.49 | 192.00 | 23.82 | 21.17 | 23.23 |
Annual Sum or Average | 1028.50 | 22.83 | 3532.17 | 23.87 | 247.33 | 23.57 |
Minimum of Months | 9.67 | 22.49 | 127.83 | 23.73 | 4.33 | 22.65 |
Maximum of Months | 212.67 | 23.89 | 410.17 | 23.89 | 36.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.77125 | 47.99407 | 0.00655 | 7.27644 |
February | 376.00000 | 23.12840 | 51.32463 | 0.13262 | 7.90963 |
March | 422.00000 | 23.35838 | 48.07761 | 0.18334 | 7.60427 |
April | 405.00000 | 23.84469 | 52.61431 | 0.39629 | 8.58847 |
May | 418.00000 | 23.88961 | 56.86446 | -0.3884 | 8.18840 |
June | 408.00000 | 23.88964 | 55.69710 | -0.3696 | 7.91172 |
July | 415.00000 | 23.88963 | 57.89718 | -0.3472 | 7.56762 |
August | 422.00000 | 23.88962 | 57.19362 | -0.3519 | 7.63107 |
September | 405.00000 | 23.88961 | 58.17791 | -0.3711 | 7.92265 |
October | 414.00000 | 23.87717 | 53.58684 | 0.46511 | 9.74454 |
November | 399.00000 | 23.75258 | 49.05072 | 0.32548 | 7.80594 |
December | 415.00000 | 23.16372 | 48.92432 | 0.13837 | 7.50596 |
Annual Sum or Average | 4913.00000 | 23.61429 | 53.13327 | -0.0175 | 7.97026 |
Minimum of Months | 376.00000 | 22.77125 | 47.99407 | -0.3884 | 7.27644 |
Maximum of Months | 422.00000 | 23.88964 | 58.17791 | 0.46511 | 9.74454 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.85026 | 45.39714 | 0.10118 | 7.23662 |
February | 376.00000 | 23.22225 | 49.00118 | 0.22903 | 8.24906 |
March | 422.00000 | 23.39825 | 46.75340 | 0.27084 | 8.18011 |
April | 405.00000 | 23.86294 | 52.59588 | 0.46838 | 9.85598 |
May | 418.00000 | 23.91386 | 59.66068 | -0.2988 | 6.90319 |
June | 408.00000 | 23.91382 | 59.50648 | -0.2813 | 6.69993 |
July | 415.00000 | 23.91488 | 62.60626 | -0.2599 | 6.45166 |
August | 422.00000 | 23.91408 | 61.66091 | -0.2695 | 6.55665 |
September | 405.00000 | 23.91399 | 62.42443 | -0.2859 | 6.75097 |
October | 414.00000 | 23.89056 | 55.83291 | 0.52608 | 11.04856 |
November | 399.00000 | 23.75023 | 49.18100 | 0.39365 | 8.80118 |
December | 415.00000 | 23.18082 | 47.73659 | 0.21841 | 7.94417 |
Annual Sum or Average | 4913.00000 | 23.64576 | 54.40669 | 0.06522 | 7.88143 |
Minimum of Months | 376.00000 | 22.85026 | 45.39714 | -0.2988 | 6.45166 |
Maximum of Months | 422.00000 | 23.91488 | 62.60626 | 0.52608 | 11.04856 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.55746 | 39.27789 | 0.30443 | 8.25269 |
February | 376.00000 | 23.59470 | 42.49848 | 0.33975 | 9.00848 |
March | 422.00000 | 23.56713 | 42.43660 | 0.30493 | 8.50956 |
April | 405.00000 | 23.85872 | 48.10975 | 0.45222 | 9.56005 |
May | 418.00000 | 23.88966 | 54.08370 | -0.3111 | 7.10807 |
June | 408.00000 | 23.88966 | 53.71854 | -0.2926 | 6.89666 |
July | 415.00000 | 23.88962 | 55.95808 | -0.2664 | 6.58420 |
August | 422.00000 | 23.88953 | 54.53238 | -0.2575 | 6.49492 |
September | 405.00000 | 23.88959 | 54.31879 | -0.2678 | 6.63284 |
October | 414.00000 | 23.88257 | 48.41221 | 0.56025 | 11.84296 |
November | 399.00000 | 23.86248 | 42.37817 | 0.47303 | 10.00172 |
December | 415.00000 | 23.65241 | 41.51061 | 0.37043 | 9.12439 |
Annual Sum or Average | 4913.00000 | 23.78597 | 48.15187 | 0.11458 | 8.32313 |
Minimum of Months | 376.00000 | 23.55746 | 39.27789 | -0.3111 | 6.49492 |
Maximum of Months | 422.00000 | 23.88966 | 55.95808 | 0.56025 | 11.84296 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.18388 | 41.96508 | 0.20663 | 7.88089 |
February | 376.00000 | 23.30277 | 45.32361 | 0.26074 | 8.72405 |
March | 422.00000 | 23.24716 | 45.46264 | 0.22166 | 8.38104 |
April | 405.00000 | 23.77478 | 52.09175 | 0.42611 | 9.31380 |
May | 418.00000 | 23.88958 | 57.56862 | -0.3314 | 7.36443 |
June | 408.00000 | 23.88961 | 56.78628 | -0.3158 | 7.17775 |
July | 415.00000 | 23.88960 | 59.15829 | -0.2871 | 6.80804 |
August | 422.00000 | 23.88951 | 57.50679 | -0.2818 | 6.75338 |
September | 405.00000 | 23.88952 | 57.56908 | -0.2903 | 6.87646 |
October | 414.00000 | 23.86521 | 50.42789 | 0.53885 | 11.40657 |
November | 399.00000 | 23.79959 | 44.46766 | 0.44121 | 9.54526 |
December | 415.00000 | 23.33417 | 43.85343 | 0.28348 | 8.74080 |
Annual Sum or Average | 4913.00000 | 23.66428 | 51.06514 | 0.06992 | 8.23880 |
Minimum of Months | 376.00000 | 23.18388 | 41.96508 | -0.3314 | 6.75338 |
Maximum of Months | 422.00000 | 23.88961 | 59.15829 | 0.53885 | 11.40657 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.234125E+10 | 0.590761E+09 | 113.70 | 0.147270E+10 | 0.868553E+09 | 0.00 | 1.00 | 01-JAN-20:50 | 0.00 | 01-JAN-00:05 | 39990.79 | 01-JAN-20:50 | 21486.91 | 01-JAN-20:50 | 18503.87 | 01-JAN-20:50 | 8465.44 | 01-JAN-20:50 | 0.00 | 01-JAN-00:05 |
February | 0.341103E+10 | 0.856328E+09 | 145.87 | 0.215537E+10 | 0.125565E+10 | 0.00 | 1.00 | 24-FEB-22:05 | 0.00 | 01-FEB-00:10 | 40891.20 | 28-FEB-21:50 | 19862.58 | 27-FEB-22:25 | 22612.47 | 28-FEB-21:50 | 8593.89 | 28-FEB-21:50 | 0.00 | 01-FEB-00:10 |
March | 0.553107E+10 | 0.139973E+10 | 237.16 | 0.369996E+10 | 0.183111E+10 | 0.00 | 1.00 | 28-MAR-21:25 | 0.00 | 01-MAR-00:05 | 40390.82 | 28-MAR-21:25 | 19402.55 | 28-MAR-21:25 | 20988.27 | 28-MAR-21:25 | 8525.83 | 28-MAR-21:25 | 0.00 | 01-MAR-00:05 |
April | 0.117405E+11 | 0.296434E+10 | 396.38 | 0.818990E+10 | 0.355063E+10 | 0.00 | 1.00 | 18-APR-20:32 | 0.00 | 01-APR-00:10 | 40192.64 | 30-APR-19:40 | 24728.85 | 18-APR-20:32 | 16890.58 | 30-APR-19:40 | 8496.56 | 30-APR-19:40 | 0.00 | 01-APR-00:10 |
May | 0.269151E+11 | 0.670757E+10 | 593.92 | 0.183967E+11 | 0.851833E+10 | 0.00 | 1.00 | 12-MAY-03:00 | 0.00 | 01-MAY-00:10 | 36338.98 | 07-MAY-18:13 | 28094.95 | 07-MAY-18:13 | 9762.13 | 23-MAY-20:20 | 8939.78 | 07-MAY-18:13 | 0.00 | 01-MAY-00:10 |
June | 0.290058E+11 | 0.722424E+10 | 596.14 | 0.200885E+11 | 0.891731E+10 | 0.00 | 1.00 | 07-JUN-00:20 | 0.00 | 01-JUN-00:05 | 40195.63 | 07-JUN-00:20 | 27578.15 | 28-JUN-20:10 | 15427.42 | 07-JUN-00:20 | 8882.44 | 28-JUN-20:10 | 0.00 | 01-JUN-00:05 |
July | 0.320967E+11 | 0.792840E+10 | 625.33 | 0.212619E+11 | 0.108348E+11 | 0.00 | 1.00 | 07-JUL-20:10 | 0.00 | 01-JUL-00:05 | 39261.14 | 07-JUL-20:10 | 29859.22 | 07-JUL-21:23 | 11731.86 | 04-JUL-18:10 | 9672.77 | 23-JUL-18:10 | 0.00 | 01-JUL-00:05 |
August | 0.320937E+11 | 0.790815E+10 | 633.36 | 0.215147E+11 | 0.105789E+11 | 0.00 | 1.00 | 02-AUG-20:43 | 0.00 | 01-AUG-00:05 | 39987.12 | 10-AUG-20:10 | 31054.46 | 02-AUG-22:03 | 13484.73 | 10-AUG-20:10 | 9649.39 | 24-AUG-20:10 | 0.00 | 01-AUG-00:05 |
September | 0.279170E+11 | 0.680004E+10 | 588.36 | 0.181876E+11 | 0.972945E+10 | 0.00 | 1.00 | 03-SEP-18:43 | 0.00 | 01-SEP-00:05 | 39313.29 | 03-SEP-18:43 | 30958.30 | 10-SEP-22:03 | 11765.45 | 09-SEP-21:10 | 10022.84 | 09-SEP-21:10 | 0.00 | 01-SEP-00:05 |
October | 0.226340E+11 | 0.556970E+10 | 535.71 | 0.152837E+11 | 0.735032E+10 | 0.00 | 1.00 | 01-OCT-01:20 | 0.00 | 01-OCT-00:05 | 40324.86 | 06-OCT-20:10 | 34251.88 | 26-OCT-20:17 | 14989.26 | 01-OCT-01:20 | 9195.29 | 13-OCT-20:10 | 0.00 | 01-OCT-00:05 |
November | 0.804425E+10 | 0.201088E+10 | 313.16 | 0.540574E+10 | 0.263851E+10 | 0.00 | 1.00 | 04-NOV-23:23 | 0.00 | 01-NOV-00:05 | 40160.01 | 04-NOV-23:23 | 22117.00 | 11-NOV-22:15 | 20389.46 | 08-NOV-05:22 | 8491.62 | 04-NOV-23:23 | 0.00 | 01-NOV-00:05 |
December | 0.506158E+10 | 0.125780E+10 | 196.05 | 0.328929E+10 | 0.177229E+10 | 0.00 | 1.00 | 17-DEC-08:61 | 0.00 | 01-DEC-00:05 | 39423.44 | 17-DEC-08:61 | 25293.70 | 17-DEC-08:61 | 14129.74 | 17-DEC-08:61 | 8371.05 | 17-DEC-08:61 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.206792E+12 | 0.512179E+11 | 4975.13 | 0.138946E+12 | 0.678459E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.234125E+10 | 0.590761E+09 | 113.70 | 0.147270E+10 | 0.868553E+09 | 0.00 | 1.00 | 0.00 | 36338.98 | 19402.55 | 9762.13 | 8371.05 | 0.00 | |||||||
Maximum of Months | 0.320967E+11 | 0.792840E+10 | 633.36 | 0.215147E+11 | 0.108348E+11 | 0.00 | 1.00 | 0.00 | 40891.20 | 34251.88 | 22612.47 | 10022.84 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.125823E+11 | 0.349350E+10 | 132.16 | 0.756089E+10 | 0.502141E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 179842.54 | 19-JAN-07:03 | 106980.16 | 01-JAN-09:02 | 97990.92 | 19-JAN-07:03 | 42214.32 | 19-JAN-07:03 | 0.00 | 01-JAN-00:05 |
February | 0.195185E+11 | 0.535682E+10 | 161.48 | 0.118083E+11 | 0.771019E+10 | 0.00 | 1.00 | 01-FEB-07:03 | 0.00 | 01-FEB-00:10 | 179190.48 | 03-FEB-07:03 | 90359.81 | 28-FEB-07:02 | 91234.74 | 03-FEB-07:03 | 42121.06 | 03-FEB-07:03 | 0.00 | 01-FEB-00:10 |
March | 0.307255E+11 | 0.844194E+10 | 240.90 | 0.194345E+11 | 0.112910E+11 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:05 | 183622.78 | 07-MAR-07:02 | 111418.49 | 30-MAR-06:02 | 90338.31 | 31-MAR-06:03 | 42679.70 | 07-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.592772E+11 | 0.161377E+11 | 355.94 | 0.382150E+11 | 0.210622E+11 | 0.00 | 1.00 | 01-APR-06:03 | 0.00 | 01-APR-00:10 | 184474.89 | 29-APR-06:02 | 138643.62 | 18-APR-06:03 | 97154.07 | 30-APR-08:62 | 43448.80 | 29-APR-06:02 | 0.00 | 01-APR-00:10 |
May | 0.120037E+12 | 0.316814E+11 | 441.42 | 0.718423E+11 | 0.481945E+11 | 0.00 | 1.00 | 01-MAY-06:02 | 0.00 | 01-MAY-00:10 | 188303.73 | 23-MAY-06:02 | 120278.16 | 12-MAY-06:02 | 91286.03 | 23-MAY-06:04 | 45710.69 | 28-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.128975E+12 | 0.338977E+11 | 430.66 | 0.766939E+11 | 0.522807E+11 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:05 | 187877.43 | 19-JUN-06:02 | 122118.53 | 11-JUN-08:62 | 87729.66 | 19-JUN-06:04 | 46097.54 | 18-JUN-08:62 | 0.00 | 01-JUN-00:05 |
July | 0.142202E+12 | 0.367378E+11 | 439.52 | 0.785431E+11 | 0.636589E+11 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 189453.42 | 02-JUL-08:62 | 113438.81 | 19-JUL-06:02 | 91594.81 | 02-JUL-08:06 | 46844.08 | 09-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.138149E+12 | 0.358088E+11 | 447.51 | 0.780318E+11 | 0.601175E+11 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:05 | 189523.87 | 06-AUG-08:62 | 119205.52 | 04-AUG-06:02 | 91061.61 | 06-AUG-08:06 | 46059.05 | 06-AUG-08:06 | 0.00 | 01-AUG-00:05 |
September | 0.119923E+12 | 0.308463E+11 | 427.03 | 0.654738E+11 | 0.544491E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:05 | 188259.93 | 17-SEP-08:62 | 117102.15 | 23-SEP-06:02 | 91426.59 | 05-SEP-06:04 | 48674.20 | 10-SEP-08:15 | 0.00 | 01-SEP-00:05 |
October | 0.986051E+11 | 0.257996E+11 | 403.17 | 0.577627E+11 | 0.408424E+11 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 188779.14 | 07-OCT-06:02 | 149311.49 | 27-OCT-06:02 | 93424.95 | 22-OCT-08:04 | 45312.27 | 07-OCT-06:02 | 0.00 | 01-OCT-00:05 |
November | 0.410671E+11 | 0.110757E+11 | 293.66 | 0.251041E+11 | 0.159629E+11 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:05 | 185597.14 | 02-NOV-06:02 | 118264.44 | 06-NOV-07:03 | 96608.88 | 04-NOV-06:04 | 43924.34 | 11-NOV-09:02 | 0.00 | 01-NOV-00:05 |
December | 0.257381E+11 | 0.694336E+10 | 192.86 | 0.153548E+11 | 0.103833E+11 | 0.00 | 1.00 | 10-DEC-09:02 | 0.00 | 01-DEC-00:05 | 184563.52 | 15-DEC-07:02 | 112749.63 | 17-DEC-09:02 | 82590.46 | 12-DEC-07:04 | 42794.49 | 15-DEC-07:02 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.936799E+12 | 0.246221E+12 | 3966.31 | 0.545825E+12 | 0.390974E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.125823E+11 | 0.349350E+10 | 132.16 | 0.756089E+10 | 0.502141E+10 | 0.00 | 1.00 | 0.00 | 179190.48 | 90359.81 | 82590.46 | 42121.06 | 0.00 | |||||||
Maximum of Months | 0.142202E+12 | 0.367378E+11 | 447.51 | 0.785431E+11 | 0.636589E+11 | 0.00 | 1.00 | 0.00 | 189523.87 | 149311.49 | 97990.92 | 48674.20 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.430532E+10 | 0.102946E+10 | 271.06 | 0.312773E+10 | 0.117759E+10 | 0.00 | 1.00 | 01-JAN-00:55 | 0.00 | 01-JAN-00:05 | 24262.24 | 16-JAN-19:12 | 16662.64 | 02-JAN-21:15 | 11195.72 | 16-JAN-19:55 | 5155.41 | 16-JAN-19:12 | 0.00 | 01-JAN-00:05 |
February | 0.551187E+10 | 0.130240E+10 | 276.69 | 0.396216E+10 | 0.154971E+10 | 0.00 | 1.00 | 01-FEB-21:12 | 0.00 | 01-FEB-00:25 | 24649.62 | 01-FEB-23:01 | 13179.25 | 27-FEB-21:10 | 12406.62 | 01-FEB-21:12 | 5221.55 | 01-FEB-23:01 | 0.00 | 01-FEB-00:10 |
March | 0.627569E+10 | 0.151452E+10 | 325.15 | 0.455076E+10 | 0.172493E+10 | 0.00 | 1.00 | 01-MAR-01:50 | 0.00 | 01-MAR-00:15 | 24934.24 | 27-MAR-21:05 | 16954.46 | 04-MAR-22:25 | 13027.71 | 27-MAR-21:05 | 5265.26 | 27-MAR-21:05 | 0.00 | 01-MAR-00:05 |
April | 0.100100E+11 | 0.246136E+10 | 468.28 | 0.723240E+10 | 0.277760E+10 | 0.00 | 1.00 | 03-APR-20:20 | 0.00 | 01-APR-00:10 | 24857.52 | 15-APR-21:25 | 20562.74 | 17-APR-20:11 | 12825.64 | 15-APR-21:25 | 5253.90 | 15-APR-21:25 | 0.00 | 01-APR-00:10 |
May | 0.187479E+11 | 0.463021E+10 | 627.42 | 0.128717E+11 | 0.587624E+10 | 0.00 | 1.00 | 11-MAY-12:50 | 0.00 | 01-MAY-00:10 | 20474.85 | 25-MAY-20:10 | 15282.39 | 07-MAY-18:43 | 5945.23 | 24-MAY-20:10 | 4930.61 | 25-MAY-20:10 | 0.00 | 01-MAY-00:10 |
June | 0.196382E+11 | 0.485903E+10 | 615.92 | 0.134992E+11 | 0.613902E+10 | 0.00 | 1.00 | 02-JUN-10:30 | 0.00 | 01-JUN-00:05 | 21633.60 | 28-JUN-20:10 | 16033.27 | 28-JUN-20:10 | 6648.91 | 29-JUN-20:10 | 5161.71 | 28-JUN-20:10 | 0.00 | 01-JUN-00:05 |
July | 0.217960E+11 | 0.534407E+10 | 640.83 | 0.142808E+11 | 0.751524E+10 | 0.00 | 1.00 | 07-JUL-20:43 | 0.00 | 01-JUL-00:10 | 24147.17 | 19-JUL-20:43 | 18614.73 | 07-JUL-21:23 | 7033.13 | 04-JUL-18:10 | 5777.01 | 07-JUL-20:43 | 0.00 | 01-JUL-00:05 |
August | 0.224070E+11 | 0.547901E+10 | 647.62 | 0.150601E+11 | 0.734690E+10 | 0.00 | 1.00 | 02-AUG-20:43 | 0.00 | 01-AUG-00:05 | 24611.16 | 10-AUG-20:10 | 19989.27 | 30-AUG-21:23 | 7988.43 | 10-AUG-20:10 | 5948.43 | 24-AUG-20:08 | 0.00 | 01-AUG-00:05 |
September | 0.206447E+11 | 0.497964E+10 | 621.13 | 0.137139E+11 | 0.693080E+10 | 0.00 | 1.00 | 03-SEP-18:43 | 0.00 | 01-SEP-00:33 | 24124.22 | 10-SEP-18:08 | 19819.17 | 10-SEP-21:23 | 7163.12 | 09-SEP-21:10 | 6222.65 | 09-SEP-21:10 | 0.00 | 01-SEP-00:05 |
October | 0.191689E+11 | 0.462287E+10 | 587.43 | 0.136208E+11 | 0.554814E+10 | 0.00 | 1.00 | 01-OCT-02:00 | 0.00 | 01-OCT-00:25 | 24754.69 | 07-OCT-21:43 | 20955.79 | 26-OCT-20:10 | 8839.97 | 29-OCT-22:25 | 5649.10 | 13-OCT-20:08 | 0.00 | 01-OCT-00:05 |
November | 0.103309E+11 | 0.245718E+10 | 437.62 | 0.765382E+10 | 0.267709E+10 | 0.00 | 1.00 | 02-NOV-20:43 | 0.00 | 01-NOV-00:10 | 24624.27 | 07-NOV-21:43 | 20826.87 | 22-NOV-21:15 | 11037.61 | 20-NOV-21:12 | 5477.79 | 07-NOV-21:43 | 0.00 | 01-NOV-00:05 |
December | 0.714597E+10 | 0.169488E+10 | 343.73 | 0.522851E+10 | 0.191746E+10 | 0.00 | 1.00 | 01-DEC-21:15 | 0.00 | 01-DEC-00:05 | 24062.91 | 31-DEC-19:25 | 17348.43 | 07-DEC-21:15 | 10590.24 | 27-DEC-23:20 | 5118.51 | 31-DEC-19:25 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.165982E+12 | 0.403746E+11 | 5862.89 | 0.114802E+12 | 0.511807E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.430532E+10 | 0.102946E+10 | 271.06 | 0.312773E+10 | 0.117759E+10 | 0.00 | 1.00 | 0.00 | 20474.85 | 13179.25 | 5945.23 | 4930.61 | 0.00 | |||||||
Maximum of Months | 0.224070E+11 | 0.547901E+10 | 647.62 | 0.150601E+11 | 0.751524E+10 | 0.00 | 1.00 | 0.00 | 24934.24 | 20955.79 | 13027.71 | 6222.65 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.278909E+10 | 0.667004E+09 | 196.41 | 0.187233E+10 | 0.916760E+09 | 0.00 | 1.00 | 01-JAN-01:00 | 0.00 | 01-JAN-00:05 | 20449.57 | 18-JAN-22:40 | 12696.33 | 29-JAN-19:22 | 11121.69 | 18-JAN-22:40 | 4316.48 | 18-JAN-22:40 | 0.00 | 01-JAN-00:05 |
February | 0.362456E+10 | 0.856818E+09 | 210.81 | 0.242297E+10 | 0.120159E+10 | 0.00 | 1.00 | 21-FEB-22:05 | 0.00 | 01-FEB-00:10 | 20293.28 | 22-FEB-21:12 | 10315.50 | 23-FEB-21:12 | 10880.54 | 22-FEB-21:12 | 4293.13 | 22-FEB-21:12 | 0.00 | 01-FEB-00:10 |
March | 0.402495E+10 | 0.980033E+09 | 253.32 | 0.269912E+10 | 0.132583E+10 | 0.00 | 1.00 | 24-MAR-20:22 | 0.00 | 01-MAR-00:10 | 20569.79 | 30-MAR-20:20 | 12996.27 | 24-MAR-22:22 | 11052.14 | 30-MAR-20:20 | 4333.36 | 30-MAR-20:20 | 0.00 | 01-MAR-00:05 |
April | 0.658903E+10 | 0.163122E+10 | 384.13 | 0.442428E+10 | 0.216475E+10 | 0.00 | 1.00 | 18-APR-20:20 | 0.00 | 01-APR-00:10 | 20228.54 | 19-APR-20:20 | 13946.68 | 17-APR-20:41 | 8887.15 | 19-APR-00:20 | 4283.00 | 19-APR-20:20 | 0.00 | 01-APR-00:10 |
May | 0.146377E+11 | 0.358838E+10 | 602.47 | 0.935435E+10 | 0.528336E+10 | 0.00 | 1.00 | 11-MAY-14:40 | 0.00 | 01-MAY-00:10 | 17297.67 | 07-MAY-18:43 | 13009.18 | 07-MAY-18:43 | 5382.26 | 26-MAY-10:30 | 4097.26 | 07-MAY-18:10 | 0.00 | 01-MAY-00:10 |
June | 0.156652E+11 | 0.383270E+10 | 598.83 | 0.100206E+11 | 0.564461E+10 | 0.00 | 1.00 | 07-JUN-00:20 | 0.00 | 01-JUN-00:05 | 20348.70 | 07-JUN-00:20 | 12560.30 | 28-JUN-20:10 | 8232.44 | 07-JUN-00:20 | 4329.53 | 07-JUN-00:20 | 0.00 | 01-JUN-00:05 |
July | 0.178281E+11 | 0.431611E+10 | 632.08 | 0.108384E+11 | 0.698972E+10 | 0.00 | 1.00 | 07-JUL-20:43 | 0.00 | 01-JUL-00:10 | 19944.17 | 23-JUL-18:10 | 14493.56 | 07-JUL-21:23 | 6991.21 | 04-JUL-18:10 | 4905.40 | 23-JUL-18:10 | 0.00 | 01-JUL-00:05 |
August | 0.183445E+11 | 0.444181E+10 | 641.93 | 0.114899E+11 | 0.685457E+10 | 0.00 | 1.00 | 02-AUG-20:43 | 0.00 | 01-AUG-00:05 | 20706.87 | 10-AUG-20:10 | 15754.63 | 30-AUG-22:03 | 7815.96 | 10-AUG-20:10 | 4884.60 | 24-AUG-20:08 | 0.00 | 01-AUG-00:05 |
September | 0.166428E+11 | 0.398376E+10 | 611.38 | 0.102497E+11 | 0.639312E+10 | 0.00 | 1.00 | 03-SEP-18:10 | 0.00 | 01-SEP-00:33 | 20081.65 | 11-SEP-20:43 | 16047.23 | 10-SEP-22:43 | 6593.62 | 09-SEP-21:10 | 5102.57 | 09-SEP-21:10 | 0.00 | 01-SEP-00:05 |
October | 0.155763E+11 | 0.373430E+10 | 571.88 | 0.103824E+11 | 0.519387E+10 | 0.00 | 1.00 | 01-OCT-01:20 | 0.00 | 01-OCT-00:25 | 20629.86 | 24-OCT-20:10 | 16684.23 | 26-OCT-20:10 | 8957.61 | 31-OCT-04:20 | 4639.71 | 13-OCT-20:08 | 0.00 | 01-OCT-00:05 |
November | 0.761327E+10 | 0.180947E+10 | 394.95 | 0.528028E+10 | 0.233299E+10 | 0.00 | 1.00 | 02-NOV-20:43 | 0.00 | 01-NOV-00:05 | 20487.87 | 29-NOV-21:20 | 16661.45 | 22-NOV-21:20 | 10264.96 | 29-NOV-21:20 | 4506.25 | 07-NOV-21:43 | 0.00 | 01-NOV-00:05 |
December | 0.508378E+10 | 0.120280E+10 | 287.84 | 0.349478E+10 | 0.158901E+10 | 0.00 | 1.00 | 07-DEC-21:25 | 0.00 | 01-DEC-00:05 | 20293.59 | 08-DEC-21:52 | 14132.02 | 17-DEC-20:01 | 9813.50 | 08-DEC-21:52 | 4293.18 | 08-DEC-21:52 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.128419E+12 | 0.310444E+11 | 5386.04 | 0.825291E+11 | 0.458902E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.278909E+10 | 0.667004E+09 | 196.41 | 0.187233E+10 | 0.916760E+09 | 0.00 | 1.00 | 0.00 | 17297.67 | 10315.50 | 5382.26 | 4097.26 | 0.00 | |||||||
Maximum of Months | 0.183445E+11 | 0.444181E+10 | 641.93 | 0.114899E+11 | 0.698972E+10 | 0.00 | 1.00 | 0.00 | 20706.87 | 16684.23 | 11121.69 | 5102.57 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 34.45 | 22.86 | 11.59 | 35.46 | 45.30 | 8.50 | 0.00 | 744.00 |
February | 44.86 | 30.94 | 13.93 | 52.26 | 40.38 | 1.83 | 0.00 | 672.00 |
March | 48.87 | 30.50 | 18.37 | 61.13 | 34.32 | 0.00 | 0.00 | 744.00 |
April | 62.86 | 41.21 | 21.65 | 88.43 | 25.11 | 0.00 | 0.00 | 720.00 |
May | 60.11 | 34.66 | 25.45 | 93.61 | 10.29 | 0.00 | 0.00 | 744.00 |
June | 66.44 | 38.76 | 27.68 | 104.94 | 10.10 | 0.00 | 0.00 | 720.00 |
July | 61.78 | 32.16 | 29.62 | 97.36 | 8.06 | 0.00 | 0.00 | 744.00 |
August | 57.47 | 29.05 | 28.42 | 90.86 | 9.57 | 0.00 | 0.00 | 744.00 |
September | 49.25 | 24.85 | 24.40 | 74.80 | 11.59 | 0.00 | 0.00 | 720.00 |
October | 46.10 | 27.34 | 18.77 | 66.77 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 37.62 | 25.73 | 11.89 | 44.23 | 34.92 | 4.00 | 0.00 | 720.00 |
December | 31.45 | 20.64 | 10.81 | 32.50 | 40.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.11 | 29.85 | 20.25 | 70.26 | 23.85 | 14.33 | 0.00 | 8760.00 |
Minimum of Months | 31.45 | 20.64 | 10.81 | 32.50 | 8.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 66.44 | 41.21 | 29.62 | 104.94 | 45.30 | 8.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1051.47 | 749.97 | 301.50 | 1466.26 | 621.86 | 0.00 | 0.00 | 744.00 |
February | 953.42 | 617.16 | 336.26 | 1310.30 | 530.01 | 0.00 | 0.00 | 672.00 |
March | 608.45 | 274.50 | 333.96 | 782.11 | 462.38 | 0.00 | 0.00 | 744.00 |
April | 450.91 | 105.51 | 345.41 | 591.11 | 292.64 | 0.00 | 0.00 | 720.00 |
May | 344.55 | 14.51 | 330.03 | 645.07 | 62.60 | 0.00 | 0.00 | 744.00 |
June | 340.42 | 3.11 | 337.31 | 682.02 | 52.84 | 0.00 | 0.00 | 720.00 |
July | 356.35 | 6.46 | 349.88 | 709.89 | 29.85 | 0.00 | 0.00 | 744.00 |
August | 419.18 | 50.19 | 368.99 | 781.40 | 54.79 | 0.00 | 0.00 | 744.00 |
September | 503.00 | 132.47 | 370.53 | 860.08 | 86.12 | 0.00 | 0.00 | 720.00 |
October | 780.53 | 406.55 | 373.98 | 1287.52 | 179.65 | 0.00 | 0.00 | 744.00 |
November | 993.60 | 684.18 | 309.42 | 1481.15 | 413.56 | 0.00 | 0.00 | 720.00 |
December | 1027.44 | 737.94 | 289.49 | 1500.25 | 548.64 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 650.85 | 313.65 | 337.20 | 1006.76 | 276.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 340.42 | 3.11 | 289.49 | 591.11 | 29.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1051.47 | 749.97 | 373.98 | 1500.25 | 621.86 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1051.47 | 749.97 | 301.50 | 1470.76 | 599.05 | 0.00 | 0.00 | 744.00 |
February | 953.42 | 617.16 | 336.26 | 1313.44 | 512.80 | 0.00 | 0.00 | 672.00 |
March | 608.45 | 274.50 | 333.96 | 784.70 | 445.00 | 0.00 | 0.00 | 744.00 |
April | 450.91 | 105.51 | 345.41 | 588.68 | 285.26 | 0.00 | 0.00 | 720.00 |
May | 344.55 | 14.51 | 330.03 | 639.58 | 60.28 | 0.00 | 0.00 | 744.00 |
June | 340.42 | 3.11 | 337.31 | 676.03 | 50.48 | 0.00 | 0.00 | 720.00 |
July | 356.35 | 6.46 | 349.88 | 704.65 | 28.18 | 0.00 | 0.00 | 744.00 |
August | 419.18 | 50.19 | 368.99 | 775.73 | 52.50 | 0.00 | 0.00 | 744.00 |
September | 503.00 | 132.47 | 370.53 | 854.61 | 83.41 | 0.00 | 0.00 | 720.00 |
October | 780.53 | 406.55 | 373.98 | 1282.18 | 176.84 | 0.00 | 0.00 | 744.00 |
November | 993.60 | 684.18 | 309.42 | 1478.12 | 409.95 | 0.00 | 0.00 | 720.00 |
December | 1027.44 | 737.94 | 289.49 | 1502.83 | 530.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 650.85 | 313.65 | 337.20 | 1004.58 | 268.24 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 340.42 | 3.11 | 289.49 | 588.68 | 28.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1051.47 | 749.97 | 373.98 | 1502.83 | 599.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 216.35 | 154.32 | 62.04 | 313.65 | 107.10 | 0.00 | 0.00 | 744.00 |
February | 196.18 | 126.99 | 69.19 | 277.09 | 94.14 | 0.00 | 0.00 | 672.00 |
March | 125.20 | 56.48 | 68.72 | 165.24 | 81.52 | 0.00 | 0.00 | 744.00 |
April | 92.78 | 21.71 | 71.07 | 116.71 | 57.34 | 0.00 | 0.00 | 720.00 |
May | 70.90 | 2.99 | 67.91 | 107.45 | 20.21 | 0.00 | 0.00 | 744.00 |
June | 70.05 | 0.64 | 69.41 | 111.39 | 19.33 | 0.00 | 0.00 | 720.00 |
July | 73.32 | 1.33 | 71.99 | 115.11 | 13.86 | 4.50 | 0.00 | 744.00 |
August | 86.25 | 10.33 | 75.93 | 130.82 | 20.92 | 7.83 | 0.00 | 744.00 |
September | 103.50 | 27.26 | 76.24 | 153.79 | 26.93 | 0.00 | 0.00 | 720.00 |
October | 160.60 | 83.65 | 76.95 | 244.72 | 46.12 | 3.00 | 0.00 | 744.00 |
November | 204.45 | 140.78 | 63.67 | 301.20 | 80.38 | 0.00 | 0.00 | 720.00 |
December | 211.41 | 151.84 | 59.57 | 313.27 | 96.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 133.92 | 64.54 | 69.38 | 195.48 | 55.18 | 15.33 | 0.00 | 8760.00 |
Minimum of Months | 70.05 | 0.64 | 59.57 | 107.45 | 13.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 216.35 | 154.32 | 76.95 | 313.65 | 107.10 | 7.83 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 92259173.98 | 61223580.51 | 31035593.47 | 94966793.36 | 0.121333E+09 |
February | 0.108527E+09 | 74837953.59 | 33688773.27 | 0.126433E+09 | 97676043.78 |
March | 0.130901E+09 | 81690881.41 | 49209701.87 | 0.163728E+09 | 91911338.57 |
April | 0.162946E+09 | 0.106824E+09 | 56122160.57 | 0.229214E+09 | 65079802.39 |
May | 0.161001E+09 | 92839666.76 | 68161621.37 | 0.250725E+09 | 27568105.87 |
June | 0.172217E+09 | 0.100469E+09 | 71748734.57 | 0.272006E+09 | 26182515.13 |
July | 0.165481E+09 | 86145029.06 | 79335528.51 | 0.260766E+09 | 21597494.30 |
August | 0.153921E+09 | 77796765.61 | 76124036.86 | 0.243368E+09 | 25633880.59 |
September | 0.127660E+09 | 64414712.49 | 63244910.20 | 0.193887E+09 | 30051508.81 |
October | 0.123478E+09 | 73216835.51 | 50261117.22 | 0.178849E+09 | 46651913.96 |
November | 97502092.78 | 66692792.56 | 30809300.22 | 0.114635E+09 | 90505283.04 |
December | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 0.107865E+09 |
Annual Sum or Average | 0.158012E+10 | 0.941419E+09 | 0.638702E+09 | 0.221561E+10 | 0.752057E+09 |
Minimum of Months | 84230014.97 | 55269022.67 | 28960992.30 | 87035005.67 | 21597494.30 |
Maximum of Months | 0.172217E+09 | 0.106824E+09 | 79335528.51 | 0.272006E+09 | 0.121333E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.281625E+10 | 0.200871E+10 | 0.807538E+09 | 0.392722E+10 | 0.166560E+10 |
February | 0.230652E+10 | 0.149304E+10 | 0.813480E+09 | 0.316989E+10 | 0.128221E+10 |
March | 0.162968E+10 | 0.735209E+09 | 0.894470E+09 | 0.209479E+10 | 0.123844E+10 |
April | 0.116877E+10 | 0.273478E+09 | 0.895291E+09 | 0.153216E+10 | 0.758528E+09 |
May | 0.922829E+09 | 38867334.72 | 0.883962E+09 | 0.172777E+10 | 0.167679E+09 |
June | 0.882370E+09 | 8053470.89 | 0.874316E+09 | 0.176780E+10 | 0.136964E+09 |
July | 0.954442E+09 | 17313771.82 | 0.937128E+09 | 0.190137E+10 | 79945248.12 |
August | 0.112274E+10 | 0.134426E+09 | 0.988316E+09 | 0.209291E+10 | 0.146757E+09 |
September | 0.130377E+10 | 0.343358E+09 | 0.960408E+09 | 0.222933E+10 | 0.223228E+09 |
October | 0.209056E+10 | 0.108889E+10 | 0.100167E+10 | 0.344849E+10 | 0.481171E+09 |
November | 0.257541E+10 | 0.177339E+10 | 0.802020E+09 | 0.383914E+10 | 0.107194E+10 |
December | 0.275189E+10 | 0.197651E+10 | 0.775382E+09 | 0.401826E+10 | 0.146947E+10 |
Annual Sum or Average | 0.205252E+11 | 0.989124E+10 | 0.106340E+11 | 0.317491E+11 | 0.872194E+10 |
Minimum of Months | 0.882370E+09 | 8053470.89 | 0.775382E+09 | 0.153216E+10 | 79945248.12 |
Maximum of Months | 0.281625E+10 | 0.200871E+10 | 0.100167E+10 | 0.401826E+10 | 0.166560E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.281625E+10 | 0.200871E+10 | 0.807538E+09 | 0.393928E+10 | 0.160451E+10 |
February | 0.230652E+10 | 0.149304E+10 | 0.813480E+09 | 0.317748E+10 | 0.124057E+10 |
March | 0.162968E+10 | 0.735209E+09 | 0.894470E+09 | 0.210173E+10 | 0.119188E+10 |
April | 0.116877E+10 | 0.273478E+09 | 0.895291E+09 | 0.152585E+10 | 0.739405E+09 |
May | 0.922829E+09 | 38867334.72 | 0.883962E+09 | 0.171305E+10 | 0.161445E+09 |
June | 0.882370E+09 | 8053470.89 | 0.874316E+09 | 0.175226E+10 | 0.130848E+09 |
July | 0.954442E+09 | 17313771.82 | 0.937128E+09 | 0.188733E+10 | 75467577.30 |
August | 0.112274E+10 | 0.134426E+09 | 0.988316E+09 | 0.207773E+10 | 0.140605E+09 |
September | 0.130377E+10 | 0.343358E+09 | 0.960408E+09 | 0.221515E+10 | 0.216197E+09 |
October | 0.209056E+10 | 0.108889E+10 | 0.100167E+10 | 0.343419E+10 | 0.473636E+09 |
November | 0.257541E+10 | 0.177339E+10 | 0.802020E+09 | 0.383130E+10 | 0.106260E+10 |
December | 0.275189E+10 | 0.197651E+10 | 0.775382E+09 | 0.402519E+10 | 0.142212E+10 |
Annual Sum or Average | 0.205252E+11 | 0.989124E+10 | 0.106340E+11 | 0.316805E+11 | 0.845928E+10 |
Minimum of Months | 0.882370E+09 | 8053470.89 | 0.775382E+09 | 0.152585E+10 | 75467577.30 |
Maximum of Months | 0.281625E+10 | 0.200871E+10 | 0.100167E+10 | 0.402519E+10 | 0.160451E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.579484E+09 | 0.413321E+09 | 0.166163E+09 | 0.840084E+09 | 0.286850E+09 |
February | 0.474600E+09 | 0.307214E+09 | 0.167385E+09 | 0.670332E+09 | 0.227755E+09 |
March | 0.335330E+09 | 0.151280E+09 | 0.184050E+09 | 0.442592E+09 | 0.218333E+09 |
April | 0.240491E+09 | 56272016.91 | 0.184219E+09 | 0.302522E+09 | 0.148635E+09 |
May | 0.189886E+09 | 7997520.07 | 0.181888E+09 | 0.287800E+09 | 54136778.30 |
June | 0.181560E+09 | 1657118.90 | 0.179903E+09 | 0.288716E+09 | 50096724.17 |
July | 0.196390E+09 | 3562560.66 | 0.192828E+09 | 0.308309E+09 | 37127024.34 |
August | 0.231020E+09 | 27660052.61 | 0.203360E+09 | 0.350376E+09 | 56023406.63 |
September | 0.268269E+09 | 70650884.68 | 0.197618E+09 | 0.398613E+09 | 69793667.05 |
October | 0.430164E+09 | 0.224056E+09 | 0.206108E+09 | 0.655461E+09 | 0.123534E+09 |
November | 0.529928E+09 | 0.364900E+09 | 0.165027E+09 | 0.780720E+09 | 0.208351E+09 |
December | 0.566242E+09 | 0.406696E+09 | 0.159546E+09 | 0.839051E+09 | 0.259606E+09 |
Annual Sum or Average | 0.422336E+10 | 0.203527E+10 | 0.218810E+10 | 0.616458E+10 | 0.174024E+10 |
Minimum of Months | 0.181560E+09 | 1657118.90 | 0.159546E+09 | 0.287800E+09 | 37127024.34 |
Maximum of Months | 0.579484E+09 | 0.413321E+09 | 0.206108E+09 | 0.840084E+09 | 0.286850E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 567.30 | 724.81 | 551.13 | 365.73 | 185.40 | 0.00 | 0.00 |
February | 836.20 | 646.01 | 717.77 | 494.96 | 222.81 | 0.00 | 0.00 |
March | 978.06 | 549.05 | 781.96 | 488.00 | 293.96 | 0.00 | 0.00 |
April | 1414.90 | 401.73 | 1005.84 | 659.40 | 346.43 | 0.00 | 0.00 |
May | 1497.76 | 164.68 | 961.78 | 554.60 | 407.18 | 0.00 | 0.00 |
June | 1679.05 | 161.62 | 1063.07 | 620.18 | 442.89 | 0.00 | 0.00 |
July | 1557.74 | 129.02 | 988.53 | 514.61 | 473.93 | 0.00 | 0.00 |
August | 1453.81 | 153.13 | 919.48 | 464.74 | 454.74 | 0.00 | 0.00 |
September | 1196.83 | 185.50 | 788.02 | 397.62 | 390.40 | 0.00 | 0.00 |
October | 1068.40 | 278.69 | 737.62 | 437.38 | 300.25 | 0.00 | 0.00 |
November | 707.62 | 558.67 | 601.86 | 411.68 | 190.18 | 0.00 | 0.00 |
December | 519.92 | 644.36 | 503.17 | 330.16 | 173.00 | 0.00 | 0.00 |
Annual Sum or Average | 1124.11 | 381.56 | 801.69 | 477.64 | 324.05 | 0.00 | 0.00 |
Minimum of Months | 519.92 | 129.02 | 503.17 | 330.16 | 173.00 | 0.00 | 0.00 |
Maximum of Months | 1679.05 | 724.81 | 1063.07 | 659.40 | 473.93 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1466.26 | 621.86 | 1051.47 | 749.97 | 301.50 | 0.00 | 0.00 |
February | 1310.30 | 530.01 | 953.42 | 617.16 | 336.26 | 0.00 | 0.00 |
March | 782.11 | 462.38 | 608.45 | 274.50 | 333.96 | 0.00 | 0.00 |
April | 591.11 | 292.64 | 450.91 | 105.51 | 345.41 | 0.00 | 0.00 |
May | 645.07 | 62.60 | 344.55 | 14.51 | 330.03 | 0.00 | 0.00 |
June | 682.02 | 52.84 | 340.42 | 3.11 | 337.31 | 0.00 | 0.00 |
July | 709.89 | 29.85 | 356.35 | 6.46 | 349.88 | 0.00 | 0.00 |
August | 781.40 | 54.79 | 419.18 | 50.19 | 368.99 | 0.00 | 0.00 |
September | 860.08 | 86.12 | 503.00 | 132.47 | 370.53 | 0.00 | 0.00 |
October | 1287.52 | 179.65 | 780.53 | 406.55 | 373.98 | 0.00 | 0.00 |
November | 1481.15 | 413.56 | 993.60 | 684.18 | 309.42 | 0.00 | 0.00 |
December | 1500.25 | 548.64 | 1027.44 | 737.94 | 289.49 | 0.00 | 0.00 |
Annual Sum or Average | 1006.76 | 276.57 | 650.85 | 313.65 | 337.20 | 0.00 | 0.00 |
Minimum of Months | 591.11 | 29.85 | 340.42 | 3.11 | 289.49 | 0.00 | 0.00 |
Maximum of Months | 1500.25 | 621.86 | 1051.47 | 749.97 | 373.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1470.76 | 599.05 | 1051.47 | 749.97 | 301.50 | 0.00 | 0.00 |
February | 1313.44 | 512.80 | 953.42 | 617.16 | 336.26 | 0.00 | 0.00 |
March | 784.70 | 445.00 | 608.45 | 274.50 | 333.96 | 0.00 | 0.00 |
April | 588.68 | 285.26 | 450.91 | 105.51 | 345.41 | 0.00 | 0.00 |
May | 639.58 | 60.28 | 344.55 | 14.51 | 330.03 | 0.00 | 0.00 |
June | 676.03 | 50.48 | 340.42 | 3.11 | 337.31 | 0.00 | 0.00 |
July | 704.65 | 28.18 | 356.35 | 6.46 | 349.88 | 0.00 | 0.00 |
August | 775.73 | 52.50 | 419.18 | 50.19 | 368.99 | 0.00 | 0.00 |
September | 854.61 | 83.41 | 503.00 | 132.47 | 370.53 | 0.00 | 0.00 |
October | 1282.18 | 176.84 | 780.53 | 406.55 | 373.98 | 0.00 | 0.00 |
November | 1478.12 | 409.95 | 993.60 | 684.18 | 309.42 | 0.00 | 0.00 |
December | 1502.83 | 530.96 | 1027.44 | 737.94 | 289.49 | 0.00 | 0.00 |
Annual Sum or Average | 1004.58 | 268.24 | 650.85 | 313.65 | 337.20 | 0.00 | 0.00 |
Minimum of Months | 588.68 | 28.18 | 340.42 | 3.11 | 289.49 | 0.00 | 0.00 |
Maximum of Months | 1502.83 | 599.05 | 1051.47 | 749.97 | 373.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 313.65 | 107.10 | 216.35 | 154.32 | 62.04 | 0.00 | 0.00 |
February | 277.09 | 94.14 | 196.18 | 126.99 | 69.19 | 0.00 | 0.00 |
March | 165.24 | 81.52 | 125.20 | 56.48 | 68.72 | 0.00 | 0.00 |
April | 116.71 | 57.34 | 92.78 | 21.71 | 71.07 | 0.00 | 0.00 |
May | 107.45 | 20.21 | 70.90 | 2.99 | 67.91 | 0.00 | 0.00 |
June | 111.39 | 19.33 | 70.05 | 0.64 | 69.41 | 0.00 | 0.00 |
July | 115.11 | 13.86 | 73.32 | 1.33 | 71.99 | 0.00 | 0.00 |
August | 130.82 | 20.92 | 86.25 | 10.33 | 75.93 | 0.00 | 0.00 |
September | 153.79 | 26.93 | 103.50 | 27.26 | 76.24 | 0.00 | 0.00 |
October | 244.72 | 46.12 | 160.60 | 83.65 | 76.95 | 0.00 | 0.00 |
November | 301.20 | 80.38 | 204.45 | 140.78 | 63.67 | 0.00 | 0.00 |
December | 313.27 | 96.93 | 211.41 | 151.84 | 59.57 | 0.00 | 0.00 |
Annual Sum or Average | 195.48 | 55.18 | 133.92 | 64.54 | 69.38 | 0.00 | 0.00 |
Minimum of Months | 107.45 | 13.86 | 70.05 | 0.64 | 59.57 | 0.00 | 0.00 |
Maximum of Months | 313.65 | 107.10 | 216.35 | 154.32 | 76.95 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.151947E+10 | 0.194134E+10 | 0.147615E+10 | 0.979577E+09 | 0.496569E+09 | 0.00 | 0.00 |
February | 0.202293E+10 | 0.156282E+10 | 0.173643E+10 | 0.119741E+10 | 0.539020E+09 | 0.00 | 0.00 |
March | 0.261964E+10 | 0.147058E+10 | 0.209441E+10 | 0.130705E+10 | 0.787355E+09 | 0.00 | 0.00 |
April | 0.366743E+10 | 0.104128E+10 | 0.260713E+10 | 0.170918E+10 | 0.897955E+09 | 0.00 | 0.00 |
May | 0.401159E+10 | 0.441090E+09 | 0.257602E+10 | 0.148543E+10 | 0.109059E+10 | 0.00 | 0.00 |
June | 0.435210E+10 | 0.418920E+09 | 0.275548E+10 | 0.160750E+10 | 0.114798E+10 | 0.00 | 0.00 |
July | 0.417226E+10 | 0.345560E+09 | 0.264769E+10 | 0.137832E+10 | 0.126937E+10 | 0.00 | 0.00 |
August | 0.389389E+10 | 0.410142E+09 | 0.246273E+10 | 0.124475E+10 | 0.121798E+10 | 0.00 | 0.00 |
September | 0.310219E+10 | 0.480824E+09 | 0.204255E+10 | 0.103064E+10 | 0.101192E+10 | 0.00 | 0.00 |
October | 0.286159E+10 | 0.746431E+09 | 0.197565E+10 | 0.117147E+10 | 0.804178E+09 | 0.00 | 0.00 |
November | 0.183415E+10 | 0.144808E+10 | 0.156003E+10 | 0.106708E+10 | 0.492949E+09 | 0.00 | 0.00 |
December | 0.139256E+10 | 0.172585E+10 | 0.134768E+10 | 0.884304E+09 | 0.463376E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.354498E+11 | 0.120329E+11 | 0.252820E+11 | 0.150627E+11 | 0.102192E+11 | 0.00 | 0.00 |
Minimum of Months | 0.139256E+10 | 0.345560E+09 | 0.134768E+10 | 0.884304E+09 | 0.463376E+09 | 0.00 | 0.00 |
Maximum of Months | 0.435210E+10 | 0.194134E+10 | 0.275548E+10 | 0.170918E+10 | 0.126937E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.392722E+10 | 0.166560E+10 | 0.281625E+10 | 0.200871E+10 | 0.807538E+09 | 0.00 | 0.00 |
February | 0.316989E+10 | 0.128221E+10 | 0.230652E+10 | 0.149304E+10 | 0.813480E+09 | 0.00 | 0.00 |
March | 0.209479E+10 | 0.123844E+10 | 0.162968E+10 | 0.735209E+09 | 0.894470E+09 | 0.00 | 0.00 |
April | 0.153216E+10 | 0.758528E+09 | 0.116877E+10 | 0.273478E+09 | 0.895291E+09 | 0.00 | 0.00 |
May | 0.172777E+10 | 0.167679E+09 | 0.922829E+09 | 38867334.72 | 0.883962E+09 | 0.00 | 0.00 |
June | 0.176780E+10 | 0.136964E+09 | 0.882370E+09 | 8053470.89 | 0.874316E+09 | 0.00 | 0.00 |
July | 0.190137E+10 | 79945248.12 | 0.954442E+09 | 17313771.82 | 0.937128E+09 | 0.00 | 0.00 |
August | 0.209291E+10 | 0.146757E+09 | 0.112274E+10 | 0.134426E+09 | 0.988316E+09 | 0.00 | 0.00 |
September | 0.222933E+10 | 0.223228E+09 | 0.130377E+10 | 0.343358E+09 | 0.960408E+09 | 0.00 | 0.00 |
October | 0.344849E+10 | 0.481171E+09 | 0.209056E+10 | 0.108889E+10 | 0.100167E+10 | 0.00 | 0.00 |
November | 0.383914E+10 | 0.107194E+10 | 0.257541E+10 | 0.177339E+10 | 0.802020E+09 | 0.00 | 0.00 |
December | 0.401826E+10 | 0.146947E+10 | 0.275189E+10 | 0.197651E+10 | 0.775382E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.317491E+11 | 0.872194E+10 | 0.205252E+11 | 0.989124E+10 | 0.106340E+11 | 0.00 | 0.00 |
Minimum of Months | 0.153216E+10 | 79945248.12 | 0.882370E+09 | 8053470.89 | 0.775382E+09 | 0.00 | 0.00 |
Maximum of Months | 0.401826E+10 | 0.166560E+10 | 0.281625E+10 | 0.200871E+10 | 0.100167E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.393928E+10 | 0.160451E+10 | 0.281625E+10 | 0.200871E+10 | 0.807538E+09 | 0.00 | 0.00 |
February | 0.317748E+10 | 0.124057E+10 | 0.230652E+10 | 0.149304E+10 | 0.813480E+09 | 0.00 | 0.00 |
March | 0.210173E+10 | 0.119188E+10 | 0.162968E+10 | 0.735209E+09 | 0.894470E+09 | 0.00 | 0.00 |
April | 0.152585E+10 | 0.739405E+09 | 0.116877E+10 | 0.273478E+09 | 0.895291E+09 | 0.00 | 0.00 |
May | 0.171305E+10 | 0.161445E+09 | 0.922829E+09 | 38867334.72 | 0.883962E+09 | 0.00 | 0.00 |
June | 0.175226E+10 | 0.130848E+09 | 0.882370E+09 | 8053470.89 | 0.874316E+09 | 0.00 | 0.00 |
July | 0.188733E+10 | 75467577.30 | 0.954442E+09 | 17313771.82 | 0.937128E+09 | 0.00 | 0.00 |
August | 0.207773E+10 | 0.140605E+09 | 0.112274E+10 | 0.134426E+09 | 0.988316E+09 | 0.00 | 0.00 |
September | 0.221515E+10 | 0.216197E+09 | 0.130377E+10 | 0.343358E+09 | 0.960408E+09 | 0.00 | 0.00 |
October | 0.343419E+10 | 0.473636E+09 | 0.209056E+10 | 0.108889E+10 | 0.100167E+10 | 0.00 | 0.00 |
November | 0.383130E+10 | 0.106260E+10 | 0.257541E+10 | 0.177339E+10 | 0.802020E+09 | 0.00 | 0.00 |
December | 0.402519E+10 | 0.142212E+10 | 0.275189E+10 | 0.197651E+10 | 0.775382E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.316805E+11 | 0.845928E+10 | 0.205252E+11 | 0.989124E+10 | 0.106340E+11 | 0.00 | 0.00 |
Minimum of Months | 0.152585E+10 | 75467577.30 | 0.882370E+09 | 8053470.89 | 0.775382E+09 | 0.00 | 0.00 |
Maximum of Months | 0.402519E+10 | 0.160451E+10 | 0.281625E+10 | 0.200871E+10 | 0.100167E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.840084E+09 | 0.286850E+09 | 0.579484E+09 | 0.413321E+09 | 0.166163E+09 | 0.00 | 0.00 |
February | 0.670332E+09 | 0.227755E+09 | 0.474600E+09 | 0.307214E+09 | 0.167385E+09 | 0.00 | 0.00 |
March | 0.442592E+09 | 0.218333E+09 | 0.335330E+09 | 0.151280E+09 | 0.184050E+09 | 0.00 | 0.00 |
April | 0.302522E+09 | 0.148635E+09 | 0.240491E+09 | 56272016.91 | 0.184219E+09 | 0.00 | 0.00 |
May | 0.287800E+09 | 54136778.30 | 0.189886E+09 | 7997520.07 | 0.181888E+09 | 0.00 | 0.00 |
June | 0.288716E+09 | 50096724.17 | 0.181560E+09 | 1657118.90 | 0.179903E+09 | 0.00 | 0.00 |
July | 0.308309E+09 | 37127024.34 | 0.196390E+09 | 3562560.66 | 0.192828E+09 | 0.00 | 0.00 |
August | 0.350376E+09 | 56023406.63 | 0.231020E+09 | 27660052.61 | 0.203360E+09 | 0.00 | 0.00 |
September | 0.398613E+09 | 69793667.05 | 0.268269E+09 | 70650884.68 | 0.197618E+09 | 0.00 | 0.00 |
October | 0.655461E+09 | 0.123534E+09 | 0.430164E+09 | 0.224056E+09 | 0.206108E+09 | 0.00 | 0.00 |
November | 0.780720E+09 | 0.208351E+09 | 0.529928E+09 | 0.364900E+09 | 0.165027E+09 | 0.00 | 0.00 |
December | 0.839051E+09 | 0.259606E+09 | 0.566242E+09 | 0.406696E+09 | 0.159546E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.616458E+10 | 0.174024E+10 | 0.422336E+10 | 0.203527E+10 | 0.218810E+10 | 0.00 | 0.00 |
Minimum of Months | 0.287800E+09 | 37127024.34 | 0.181560E+09 | 1657118.90 | 0.159546E+09 | 0.00 | 0.00 |
Maximum of Months | 0.840084E+09 | 0.286850E+09 | 0.579484E+09 | 0.413321E+09 | 0.206108E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.57 | 11.01 | 8.64 | 3.24 | 3.12 | 48.31 | 209.17 | 0.01 |
February | 15.49 | 12.82 | 10.40 | 2.82 | 4.36 | 58.07 | 218.23 | 0.02 |
March | 17.07 | 13.57 | 10.72 | 3.68 | 7.24 | 76.61 | 186.08 | 0.03 |
April | 21.23 | 17.53 | 15.23 | 2.65 | 11.47 | 90.28 | 216.86 | 0.02 |
May | 26.90 | 22.81 | 21.10 | 3.11 | 19.64 | 106.10 | 173.47 | 0.04 |
June | 27.61 | 23.36 | 21.62 | 2.44 | 19.77 | 115.40 | 187.69 | 0.03 |
July | 27.94 | 24.58 | 23.34 | 2.53 | 20.70 | 123.49 | 154.05 | 0.05 |
August | 27.43 | 23.89 | 22.52 | 3.20 | 20.40 | 118.51 | 145.78 | 0.03 |
September | 26.23 | 23.37 | 22.24 | 3.39 | 19.01 | 101.73 | 135.58 | 0.05 |
October | 24.23 | 20.46 | 18.40 | 4.11 | 16.60 | 78.24 | 178.15 | 0.01 |
November | 18.91 | 15.31 | 12.62 | 2.63 | 7.99 | 49.56 | 205.43 | 0.01 |
December | 15.68 | 12.87 | 10.53 | 3.17 | 6.00 | 45.08 | 191.18 | 0.02 |
Annual Sum or Average | 21.89 | 18.50 | 16.48 | 3.09 | 13.08 | 84.44 | 183.16 | 0.03 |
Minimum of Months | 13.57 | 11.01 | 8.64 | 2.44 | 3.12 | 45.08 | 135.58 | 0.01 |
Maximum of Months | 27.94 | 24.58 | 23.34 | 4.11 | 20.70 | 123.49 | 218.23 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 27.00 | 02-JAN-14:00 | 18.65 | 14.00 | 1.50 | 17.75 | 146.50 | 0.00 |
February | 28.30 | 02-FEB-12:00 | 20.77 | 17.20 | 6.60 | 17.93 | 127.50 | 748.50 |
March | 30.00 | 26-MAR-13:00 | 19.86 | 14.40 | 3.00 | 19.52 | 288.50 | 548.00 |
April | 33.30 | 28-APR-14:00 | 23.04 | 18.80 | 4.10 | 23.15 | 150.50 | 762.50 |
May | 33.90 | 07-MAY-13:00 | 23.75 | 19.40 | 4.10 | 23.15 | 287.50 | 507.50 |
June | 35.00 | 14-JUN-13:00 | 23.93 | 19.40 | 2.10 | 24.16 | 194.50 | 712.50 |
July | 36.10 | 21-JUL-15:00 | 25.95 | 22.20 | 1.50 | 26.65 | 216.00 | 245.00 |
August | 36.30 | 30-AUG-15:00 | 23.72 | 18.50 | 2.40 | 25.33 | 116.00 | 698.50 |
September | 36.40 | 09-SEP-16:00 | 26.63 | 23.40 | 4.40 | 26.48 | 114.00 | 401.50 |
October | 34.00 | 05-OCT-14:00 | 24.03 | 20.00 | 2.60 | 29.55 | 169.50 | 606.00 |
November | 30.00 | 01-NOV-13:00 | 25.01 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
December | 30.00 | 13-DEC-14:00 | 21.82 | 18.00 | 3.10 | 20.92 | 101.50 | 682.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 27.00 | 18.65 | 14.00 | 1.50 | 17.75 | 101.50 | 0.00 | |
Maximum of Months | 36.40 | 26.63 | 23.40 | 6.60 | 29.55 | 288.50 | 762.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 0.00 | 05-JAN-05:00 | -0.0 | -0.0 | 2.10 | -16.0 | 0.00 | 0.00 |
February | -3.4 | 05-FEB-07:10 | -5.2 | -9.4 | 4.68 | -21.3 | 0.00 | 0.00 |
March | 1.10 | 09-MAR-05:00 | -1.8 | -7.3 | 3.60 | -14.4 | 0.00 | 0.00 |
April | 8.30 | 11-APR-05:00 | 6.94 | 5.50 | 0.00 | -6.9 | 0.00 | 0.00 |
May | 21.10 | 07-MAY-00:00 | 19.57 | 18.90 | 0.00 | 11.46 | 0.00 | 0.00 |
June | 20.60 | 07-JUN-01:00 | 17.99 | 16.70 | 3.60 | 10.50 | 0.00 | 0.00 |
July | 22.20 | 11-JUL-19:00 | 21.37 | 21.10 | 2.10 | 20.22 | 0.00 | 0.00 |
August | 20.20 | 25-AUG-23:00 | 20.20 | 20.20 | 5.30 | 11.84 | 0.00 | 0.00 |
September | 19.20 | 07-SEP-17:00 | 19.20 | 19.20 | 2.50 | 16.85 | 35.00 | 7.00 |
October | 10.00 | 28-OCT-04:00 | 5.55 | 0.00 | 3.60 | -0.1 | 0.00 | 0.00 |
November | 7.20 | 12-NOV-07:49 | 4.11 | 0.18 | 4.60 | -9.0 | 36.00 | 517.00 |
December | 0.00 | 21-DEC-04:00 | -0.8 | -2.0 | 2.10 | -16.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -3.4 | -5.2 | -9.4 | 0.00 | -21.3 | 0.00 | 0.00 | |
Maximum of Months | 22.20 | 21.37 | 21.10 | 5.30 | 20.22 | 36.00 | 517.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 22.10 | 31-JAN-12:00 | 25.00 | 21.00 | 5.70 | 20.92 | 336.50 | 96.00 |
February | 21.48 | 24-FEB-12:00 | 27.70 | 18.80 | 4.10 | 17.75 | 165.00 | 746.50 |
March | 22.76 | 30-MAR-12:00 | 29.40 | 20.00 | 2.50 | 27.14 | 340.00 | 0.00 |
April | 25.54 | 28-APR-15:00 | 32.20 | 23.30 | 3.60 | 22.47 | 156.00 | 575.50 |
May | 25.83 | 27-MAY-13:00 | 31.70 | 23.90 | 3.10 | 22.13 | 168.50 | 735.50 |
June | 26.52 | 29-JUN-16:00 | 29.40 | 25.60 | 1.50 | 26.32 | 164.00 | 36.00 |
July | 27.16 | 22-JUL-10:00 | 32.20 | 25.60 | 2.10 | 21.96 | 191.00 | 719.50 |
August | 27.24 | 07-AUG-12:00 | 31.00 | 26.00 | 3.10 | 27.95 | 473.00 | 200.00 |
September | 27.78 | 10-SEP-12:00 | 35.00 | 25.50 | 2.90 | 24.66 | 239.50 | 662.00 |
October | 28.18 | 07-OCT-07:00 | 29.00 | 28.00 | 2.60 | 21.09 | 95.00 | 500.50 |
November | 25.01 | 01-NOV-13:00 | 30.00 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
December | 24.12 | 12-DEC-13:00 | 27.00 | 23.00 | 2.10 | 19.17 | 160.50 | 599.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 21.48 | 25.00 | 18.80 | 1.50 | 17.75 | 95.00 | 0.00 | |
Maximum of Months | 28.18 | 35.00 | 28.00 | 5.70 | 27.95 | 473.00 | 746.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.00 | 31-JAN-12:00 | 25.00 | 22.10 | 5.70 | 20.92 | 336.50 | 96.00 |
February | 20.20 | 02-FEB-22:00 | 21.50 | 20.56 | 4.80 | 14.65 | 0.00 | 0.00 |
March | 21.10 | 07-MAR-08:00 | 23.30 | 21.69 | 2.00 | 13.91 | 126.00 | 566.50 |
April | 23.30 | 28-APR-15:00 | 32.20 | 25.54 | 3.60 | 22.47 | 156.00 | 575.50 |
May | 24.40 | 26-MAY-08:20 | 27.07 | 25.08 | 3.10 | 23.71 | 252.67 | 47.33 |
June | 25.60 | 29-JUN-14:00 | 27.20 | 26.00 | 5.10 | 24.16 | 335.00 | 238.00 |
July | 25.60 | 02-JUL-05:00 | 26.10 | 25.71 | 2.60 | 19.52 | 30.50 | 8.50 |
August | 26.60 | 09-AUG-18:00 | 26.60 | 26.60 | 1.90 | 19.52 | 26.00 | 23.00 |
September | 25.50 | 10-SEP-12:00 | 35.00 | 27.78 | 2.90 | 24.66 | 239.50 | 662.00 |
October | 28.00 | 07-OCT-07:00 | 29.00 | 28.18 | 2.60 | 21.09 | 95.00 | 500.50 |
November | 23.80 | 01-NOV-10:00 | 26.10 | 24.39 | 2.00 | 22.64 | 228.50 | 113.00 |
December | 23.00 | 12-DEC-13:00 | 27.00 | 24.12 | 2.10 | 19.17 | 160.50 | 599.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.20 | 21.50 | 20.56 | 1.90 | 13.91 | 0.00 | 0.00 | |
Maximum of Months | 28.00 | 35.00 | 28.18 | 5.70 | 24.66 | 336.50 | 662.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 20.46 | 29.60 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 20.78 | 36.65 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 22.23 | 38.94 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 24.49 | 49.11 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 26.95 | 46.95 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 28.93 | 51.71 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 29.89 | 48.43 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 29.58 | 45.50 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 28.08 | 39.22 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 25.80 | 37.51 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 23.35 | 31.26 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 21.40 | 27.18 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 25.18 | 40.17 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 20.46 | 27.18 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 29.89 | 51.71 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.222877E+10 | -.182577E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -402994759.9 | 58.99 | 0.00 | 0.00 |
February | 0.200881E+10 | -.164892E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -359881865.2 | 58.99 | 0.00 | 0.00 |
March | 0.219406E+10 | -.179969E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -394368607.5 | 58.99 | 0.00 | 0.00 |
April | 0.198001E+10 | -.160595E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -374057204.9 | 58.99 | 0.00 | 0.00 |
May | 0.193016E+10 | -.154466E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385502948.2 | 58.99 | 0.00 | 0.00 |
June | 0.179460E+10 | -.142138E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -373226096.0 | 58.99 | 0.00 | 0.00 |
July | 0.176568E+10 | -.137993E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385750779.0 | 58.99 | 0.00 | 0.00 |
August | 0.182551E+10 | -.143975E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385767151.5 | 58.99 | 0.00 | 0.00 |
September | 0.181294E+10 | -.143980E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -373132917.2 | 58.99 | 0.00 | 0.00 |
October | 0.195947E+10 | -.157350E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385963709.9 | 58.99 | 0.00 | 0.00 |
November | 0.200307E+10 | -.162694E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -376133862.9 | 58.99 | 0.00 | 0.00 |
December | 0.217995E+10 | -.178274E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -397209661.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.236830E+11 | -.190890E+11 | 8760.00 | -.459399E+10 | 58.99 | |||||
Minimum of Months | 0.176568E+10 | -.182577E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -402994759.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.222877E+10 | -.137993E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -359881865.2 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 307.33 | 0.85 | 0.50 | 31-JAN-12:20 | 174.13 | 3.98 | 0.00 | 0.00 | 145.21 | 2.69 | 0.00 | 0.00 |
February | 295.50 | 0.82 | 0.50 | 01-FEB-12:30 | 212.30 | 4.80 | 0.00 | 0.83 | 176.53 | 3.37 | 0.00 | 0.17 |
March | 296.00 | 0.77 | 0.50 | 02-MAR-13:09 | 262.70 | 6.01 | 0.00 | 11.50 | 220.86 | 4.51 | 0.00 | 10.67 |
April | 347.33 | 0.76 | 0.50 | 01-APR-09:30 | 276.12 | 7.46 | 0.00 | 11.67 | 230.25 | 5.78 | 0.00 | 10.00 |
May | 353.67 | 0.75 | 0.50 | 01-MAY-09:09 | 290.89 | 9.26 | 0.00 | 11.83 | 242.04 | 7.59 | 0.00 | 8.33 |
June | 394.00 | 0.74 | 0.50 | 01-JUN-10:39 | 298.30 | 9.86 | 0.00 | 24.33 | 251.14 | 8.19 | 0.00 | 14.83 |
July | 390.00 | 0.72 | 0.50 | 01-JUL-09:00 | 324.35 | 10.21 | 0.00 | 43.67 | 272.25 | 8.58 | 0.00 | 23.17 |
August | 380.83 | 0.71 | 0.50 | 01-AUG-10:09 | 505.80 | 9.43 | 0.00 | 54.33 | 473.59 | 7.76 | 0.00 | 39.83 |
September | 342.17 | 0.72 | 0.50 | 01-SEP-11:09 | 1199.68 | 8.08 | 0.00 | 72.67 | 1275.83 | 6.50 | 0.00 | 58.33 |
October | 330.00 | 0.75 | 0.50 | 04-OCT-11:30 | 281.56 | 6.68 | 0.00 | 11.67 | 234.73 | 5.14 | 0.00 | 10.17 |
November | 308.00 | 0.84 | 0.50 | 01-NOV-12:20 | 184.79 | 4.07 | 0.00 | 0.00 | 154.56 | 2.73 | 0.00 | 0.00 |
December | 282.83 | 0.85 | 0.64 | 11-DEC-12:30 | 171.76 | 4.02 | 0.00 | 0.00 | 142.51 | 2.70 | 0.00 | 0.00 |
Annual Sum or Average | 4027.67 | 0.77 | 357.12 | 7.23 | 0.00 | 242.50 | 326.53 | 5.69 | 0.00 | 175.50 | ||
Minimum of Months | 282.83 | 0.71 | 0.50 | 171.76 | 3.98 | 0.00 | 0.00 | 142.51 | 2.69 | 0.00 | 0.00 | |
Maximum of Months | 394.00 | 0.85 | 0.64 | 1199.68 | 10.21 | 0.00 | 72.67 | 1275.83 | 8.58 | 0.00 | 58.33 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.711368E+09 | 47010.61 | 05-JAN-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.545552E+09 | 47010.61 | 05-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.313184E+09 | 47010.61 | 11-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.378269E+09 | 47010.61 | 21-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194837E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.711368E+09 | 47010.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.238530E+10 | 53425.35 | 05-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.162194E+10 | 44916.33 | 05-FEB-09:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.964179E+09 | 34922.02 | 09-MAR-07:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.144822E+10 | 42622.07 | 21-DEC-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.641964E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.238530E+10 | 53425.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 66499701.51 | 4805.61 | 21-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.101375E+09 | 28331.31 | 05-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.103363E+09 | 28331.31 | 12-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 58539054.07 | 8436.00 | 21-DEC-07:37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.329777E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.103363E+09 | 28331.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.251768E+09 | 22532.43 | 10-JAN-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.271116E+09 | 22532.43 | 05-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.338132E+09 | 22532.43 | 11-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.219002E+09 | 22532.43 | 21-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108002E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.338132E+09 | 22532.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.118162E+09 | 24845.40 | 04-JAN-17:21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.327868E+09 | 24845.40 | 04-FEB-14:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 86475371.07 | 16293.18 | 11-MAR-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.199641E+09 | 24845.40 | 20-DEC-16:41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.732146E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.327868E+09 | 24845.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.234125E+10 | 0.147270E+10 | 39990.79 | 01-JAN-20:50 | 21486.91 | 0.00 |
February | 0.00 | 0.00 | 0.341103E+10 | 0.215537E+10 | 40891.20 | 28-FEB-21:50 | 18278.73 | 0.00 |
March | 0.00 | 0.00 | 0.553107E+10 | 0.369996E+10 | 40390.82 | 28-MAR-21:25 | 19402.55 | 0.00 |
April | 0.00 | 0.00 | 0.117405E+11 | 0.818990E+10 | 40192.64 | 30-APR-19:40 | 23302.06 | 0.00 |
May | 0.00 | 0.00 | 0.269151E+11 | 0.183967E+11 | 36338.98 | 07-MAY-18:13 | 28094.95 | 0.00 |
June | 0.00 | 0.00 | 0.290058E+11 | 0.200885E+11 | 40195.63 | 07-JUN-00:20 | 24768.21 | 0.00 |
July | 0.00 | 0.00 | 0.320967E+11 | 0.212619E+11 | 39261.14 | 07-JUL-20:10 | 29026.96 | 0.00 |
August | 0.00 | 0.00 | 0.320937E+11 | 0.215147E+11 | 39987.12 | 10-AUG-20:10 | 26502.39 | 0.00 |
September | 0.00 | 0.00 | 0.279170E+11 | 0.181876E+11 | 39313.29 | 03-SEP-18:43 | 28798.50 | 0.00 |
October | 0.00 | 0.00 | 0.226340E+11 | 0.152837E+11 | 40324.86 | 06-OCT-20:10 | 27575.00 | 0.00 |
November | 0.00 | 0.00 | 0.804425E+10 | 0.540574E+10 | 40160.01 | 04-NOV-23:23 | 21232.73 | 0.00 |
December | 0.00 | 0.00 | 0.506158E+10 | 0.328929E+10 | 39423.44 | 17-DEC-08:61 | 25293.70 | 0.00 |
Annual Sum or Average | 0.206792E+12 | 0.138946E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.234125E+10 | 0.147270E+10 | 36338.98 | 18278.73 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.320967E+11 | 0.215147E+11 | 40891.20 | 29026.96 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.125823E+11 | 0.756089E+10 | 179842.54 | 19-JAN-07:03 | 81851.62 | 0.00 |
February | 0.00 | 0.00 | 0.195185E+11 | 0.118083E+11 | 179190.48 | 03-FEB-07:03 | 87955.74 | 0.00 |
March | 0.00 | 0.00 | 0.307255E+11 | 0.194345E+11 | 183622.78 | 07-MAR-07:02 | 104156.79 | 0.00 |
April | 0.00 | 0.00 | 0.592772E+11 | 0.382150E+11 | 184474.89 | 29-APR-06:02 | 106758.69 | 0.00 |
May | 0.00 | 0.00 | 0.120037E+12 | 0.718423E+11 | 188303.73 | 23-MAY-06:02 | 97501.36 | 0.00 |
June | 0.00 | 0.00 | 0.128975E+12 | 0.766939E+11 | 187877.43 | 19-JUN-06:02 | 100789.89 | 0.00 |
July | 0.00 | 0.00 | 0.142202E+12 | 0.785431E+11 | 189453.42 | 02-JUL-08:62 | 99283.72 | 0.00 |
August | 0.00 | 0.00 | 0.138149E+12 | 0.780318E+11 | 189523.87 | 06-AUG-08:62 | 99790.07 | 0.00 |
September | 0.00 | 0.00 | 0.119923E+12 | 0.654738E+11 | 188259.93 | 17-SEP-08:62 | 100132.33 | 0.00 |
October | 0.00 | 0.00 | 0.986051E+11 | 0.577627E+11 | 188779.14 | 07-OCT-06:02 | 99895.99 | 0.00 |
November | 0.00 | 0.00 | 0.410671E+11 | 0.251041E+11 | 185597.14 | 02-NOV-06:02 | 104282.27 | 0.00 |
December | 0.00 | 0.00 | 0.257381E+11 | 0.153548E+11 | 184563.52 | 15-DEC-07:02 | 103507.96 | 0.00 |
Annual Sum or Average | 0.936799E+12 | 0.545825E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.125823E+11 | 0.756089E+10 | 179190.48 | 81851.62 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.142202E+12 | 0.785431E+11 | 189523.87 | 106758.69 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.430532E+10 | 0.312773E+10 | 24262.24 | 16-JAN-19:12 | 13304.96 | 0.00 |
February | 0.00 | 0.00 | 0.551187E+10 | 0.396216E+10 | 24649.62 | 01-FEB-23:01 | 12688.92 | 0.00 |
March | 0.00 | 0.00 | 0.627569E+10 | 0.455076E+10 | 24934.24 | 27-MAR-21:05 | 11906.52 | 0.00 |
April | 0.00 | 0.00 | 0.100100E+11 | 0.723240E+10 | 24857.52 | 15-APR-21:25 | 12031.87 | 0.00 |
May | 0.00 | 0.00 | 0.187479E+11 | 0.128717E+11 | 20474.85 | 25-MAY-20:10 | 15223.92 | 0.00 |
June | 0.00 | 0.00 | 0.196382E+11 | 0.134992E+11 | 21633.60 | 28-JUN-20:10 | 16033.27 | 0.00 |
July | 0.00 | 0.00 | 0.217960E+11 | 0.142808E+11 | 24147.17 | 19-JUL-20:43 | 18441.55 | 0.00 |
August | 0.00 | 0.00 | 0.224070E+11 | 0.150601E+11 | 24611.16 | 10-AUG-20:10 | 16622.73 | 0.00 |
September | 0.00 | 0.00 | 0.206447E+11 | 0.137139E+11 | 24124.22 | 10-SEP-18:08 | 17624.79 | 0.00 |
October | 0.00 | 0.00 | 0.191689E+11 | 0.136208E+11 | 24754.69 | 07-OCT-21:43 | 17946.08 | 0.00 |
November | 0.00 | 0.00 | 0.103309E+11 | 0.765382E+10 | 24624.27 | 07-NOV-21:43 | 18202.68 | 0.00 |
December | 0.00 | 0.00 | 0.714597E+10 | 0.522851E+10 | 24062.91 | 31-DEC-19:25 | 14212.48 | 0.00 |
Annual Sum or Average | 0.165982E+12 | 0.114802E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.430532E+10 | 0.312773E+10 | 20474.85 | 11906.52 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.224070E+11 | 0.150601E+11 | 24934.24 | 18441.55 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.278909E+10 | 0.187233E+10 | 20449.57 | 18-JAN-22:40 | 9327.88 | 0.00 |
February | 0.00 | 0.00 | 0.362456E+10 | 0.242297E+10 | 20293.28 | 22-FEB-21:12 | 9412.74 | 0.00 |
March | 0.00 | 0.00 | 0.402495E+10 | 0.269912E+10 | 20569.79 | 30-MAR-20:20 | 9517.65 | 0.00 |
April | 0.00 | 0.00 | 0.658903E+10 | 0.442428E+10 | 20228.54 | 19-APR-20:20 | 11664.21 | 0.00 |
May | 0.00 | 0.00 | 0.146377E+11 | 0.935435E+10 | 17297.67 | 07-MAY-18:43 | 13009.18 | 0.00 |
June | 0.00 | 0.00 | 0.156652E+11 | 0.100206E+11 | 20348.70 | 07-JUN-00:20 | 12116.27 | 0.00 |
July | 0.00 | 0.00 | 0.178281E+11 | 0.108384E+11 | 19944.17 | 23-JUL-18:10 | 13262.21 | 0.00 |
August | 0.00 | 0.00 | 0.183445E+11 | 0.114899E+11 | 20706.87 | 10-AUG-20:10 | 12890.91 | 0.00 |
September | 0.00 | 0.00 | 0.166428E+11 | 0.102497E+11 | 20081.65 | 11-SEP-20:43 | 14495.77 | 0.00 |
October | 0.00 | 0.00 | 0.155763E+11 | 0.103824E+11 | 20629.86 | 24-OCT-20:10 | 13190.38 | 0.00 |
November | 0.00 | 0.00 | 0.761327E+10 | 0.528028E+10 | 20487.87 | 29-NOV-21:20 | 10222.91 | 0.00 |
December | 0.00 | 0.00 | 0.508378E+10 | 0.349478E+10 | 20293.59 | 08-DEC-21:52 | 10480.09 | 0.00 |
Annual Sum or Average | 0.128419E+12 | 0.825291E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.278909E+10 | 0.187233E+10 | 17297.67 | 9327.88 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.183445E+11 | 0.114899E+11 | 20706.87 | 14495.77 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 64656209.66 | 0.02 | 932.99 | 03-JAN-08:04 | 0.91 |
February | 71891547.41 | 0.03 | 932.99 | 04-FEB-08:05 | 0.91 |
March | 25498617.75 | 0.01 | 932.99 | 09-MAR-08:04 | 0.91 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 |
December | 53840189.43 | 0.02 | 932.99 | 04-DEC-08:05 | 0.91 |
Annual Sum or Average | 0.215887E+09 | 0.01 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 71891547.41 | 0.03 | 932.99 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.129597E+10 | 0.32 | 1987.57 | 05-JAN-05:02 | 0.88 |
February | 0.117341E+10 | 0.32 | 1987.57 | 05-FEB-07:01 | 0.88 |
March | 0.131068E+10 | 0.33 | 1987.57 | 11-MAR-05:02 | 0.87 |
April | 0.129157E+10 | 0.35 | 1987.57 | 18-APR-20:32 | 0.87 |
May | 0.148153E+10 | 0.44 | 1853.33 | 07-MAY-18:13 | 0.84 |
June | 0.148961E+10 | 0.46 | 1868.50 | 28-JUN-20:10 | 0.85 |
July | 0.158406E+10 | 0.48 | 1987.57 | 07-JUL-20:10 | 0.87 |
August | 0.159138E+10 | 0.48 | 1987.57 | 02-AUG-20:43 | 0.87 |
September | 0.148043E+10 | 0.46 | 1987.57 | 03-SEP-18:43 | 0.87 |
October | 0.146479E+10 | 0.43 | 1987.57 | 01-OCT-03:34 | 0.87 |
November | 0.126214E+10 | 0.34 | 1870.82 | 08-NOV-05:22 | 0.84 |
December | 0.130433E+10 | 0.33 | 1987.57 | 17-DEC-08:61 | 0.87 |
Annual Sum or Average | 0.167299E+11 | 0.40 | |||
Minimum of Months | 0.117341E+10 | 0.32 | 1853.33 | 0.84 | |
Maximum of Months | 0.159138E+10 | 0.48 | 1987.57 | 0.88 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.744104E+10 | 0.50 | 11469.28 | 01-JAN-09:02 | 1.37 |
February | 0.674001E+10 | 0.50 | 11469.28 | 01-FEB-07:03 | 1.36 |
March | 0.752914E+10 | 0.51 | 11469.28 | 01-MAR-07:03 | 1.37 |
April | 0.724418E+10 | 0.50 | 11469.28 | 01-APR-06:03 | 1.36 |
May | 0.772557E+10 | 0.51 | 11469.28 | 01-MAY-06:02 | 1.36 |
June | 0.790606E+10 | 0.53 | 11469.28 | 01-JUN-06:02 | 1.36 |
July | 0.844432E+10 | 0.54 | 11469.28 | 01-JUL-06:02 | 1.36 |
August | 0.832877E+10 | 0.53 | 11469.28 | 01-AUG-06:02 | 1.36 |
September | 0.765617E+10 | 0.52 | 11469.28 | 01-SEP-06:02 | 1.36 |
October | 0.774715E+10 | 0.51 | 11469.28 | 01-OCT-08:62 | 1.37 |
November | 0.711901E+10 | 0.50 | 11469.28 | 01-NOV-06:02 | 1.36 |
December | 0.743220E+10 | 0.50 | 11469.28 | 10-DEC-09:02 | 1.36 |
Annual Sum or Average | 0.913136E+11 | 0.51 | |||
Minimum of Months | 0.674001E+10 | 0.50 | 11469.28 | 1.36 | |
Maximum of Months | 0.844432E+10 | 0.54 | 11469.28 | 1.37 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.789888E+09 | 0.36 | 872.85 | 19-JAN-21:10 | 0.78 |
February | 0.722953E+09 | 0.37 | 1188.70 | 01-FEB-23:01 | 0.90 |
March | 0.810602E+09 | 0.37 | 1188.70 | 12-MAR-06:01 | 0.91 |
April | 0.794076E+09 | 0.40 | 1041.05 | 30-APR-22:41 | 0.85 |
May | 0.906094E+09 | 0.47 | 975.13 | 25-MAY-20:10 | 0.82 |
June | 0.917311E+09 | 0.48 | 1037.50 | 28-JUN-20:10 | 0.85 |
July | 0.987148E+09 | 0.49 | 1188.70 | 07-JUL-20:43 | 0.90 |
August | 0.101949E+10 | 0.50 | 1188.70 | 02-AUG-20:43 | 0.90 |
September | 0.961726E+09 | 0.49 | 1188.70 | 03-SEP-18:43 | 0.90 |
October | 0.100371E+10 | 0.48 | 1188.70 | 04-OCT-20:08 | 0.90 |
November | 0.830566E+09 | 0.41 | 1188.70 | 02-NOV-20:43 | 0.90 |
December | 0.822535E+09 | 0.38 | 971.36 | 15-DEC-21:10 | 0.82 |
Annual Sum or Average | 0.105661E+11 | 0.43 | |||
Minimum of Months | 0.722953E+09 | 0.36 | 872.85 | 0.78 | |
Maximum of Months | 0.101949E+10 | 0.50 | 1188.70 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.605954E+09 | 0.35 | 911.76 | 10-JAN-05:02 | 0.91 |
February | 0.551491E+09 | 0.35 | 911.76 | 05-FEB-07:01 | 0.91 |
March | 0.614253E+09 | 0.35 | 911.76 | 11-MAR-05:02 | 0.91 |
April | 0.595875E+09 | 0.37 | 836.37 | 18-APR-21:21 | 0.86 |
May | 0.683374E+09 | 0.45 | 776.40 | 07-MAY-18:43 | 0.84 |
June | 0.693823E+09 | 0.47 | 812.91 | 28-JUN-20:10 | 0.85 |
July | 0.758091E+09 | 0.49 | 911.76 | 07-JUL-20:43 | 0.90 |
August | 0.786113E+09 | 0.50 | 911.76 | 02-AUG-20:43 | 0.90 |
September | 0.739835E+09 | 0.49 | 911.76 | 03-SEP-18:10 | 0.90 |
October | 0.774908E+09 | 0.48 | 911.76 | 04-OCT-20:08 | 0.90 |
November | 0.627428E+09 | 0.39 | 911.76 | 02-NOV-20:43 | 0.90 |
December | 0.627183E+09 | 0.37 | 911.76 | 21-DEC-05:01 | 0.91 |
Annual Sum or Average | 0.805833E+10 | 0.42 | |||
Minimum of Months | 0.551491E+09 | 0.35 | 776.40 | 0.84 | |
Maximum of Months | 0.786113E+09 | 0.50 | 911.76 | 0.91 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.33 | 0.00 |
February | 0.08 | 0.00 |
March | 0.17 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.17 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.22 | 0.00 |
November | 0.00 | 0.00 |
December | 0.25 | 0.00 |
Annual Sum or Average | 1.22 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.33 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.31 | 25.84 |
February | 0.86 | 25.84 |
March | 1.24 | 25.84 |
April | 2.14 | 25.84 |
May | 0.75 | 0.00 |
June | 1.25 | 0.00 |
July | 1.33 | 0.00 |
August | 1.42 | 0.00 |
September | 0.50 | 0.00 |
October | 1.21 | 11.58 |
November | 1.11 | 25.84 |
December | 1.74 | 25.84 |
Annual Sum or Average | 13.85 | 14.80 |
Minimum of Months | 0.31 | 0.00 |
Maximum of Months | 2.14 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.48 | 0.27 |
February | 0.75 | 0.00 |
March | 1.86 | 0.05 |
April | 0.46 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 1.49 | 0.07 |
November | 2.75 | 0.00 |
December | 1.62 | 0.31 |
Annual Sum or Average | 10.41 | 0.11 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.75 | 0.31 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.67 | 0.00 |
February | 0.67 | 0.00 |
March | 0.54 | 0.19 |
April | 0.20 | 0.00 |
May | 0.00 | 0.00 |
June | 0.17 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.61 | 0.17 |
November | 3.77 | 0.04 |
December | 0.79 | 0.47 |
Annual Sum or Average | 8.41 | 0.08 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.77 | 0.47 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 6.18 | 0.00 |
February | 4.12 | 0.00 |
March | 3.85 | 0.00 |
April | 2.68 | 0.00 |
May | 0.58 | 0.00 |
June | 1.17 | 0.00 |
July | 0.72 | 0.00 |
August | 1.39 | 0.00 |
September | 1.43 | 0.00 |
October | 3.81 | 0.00 |
November | 3.51 | 0.00 |
December | 4.01 | 0.00 |
Annual Sum or Average | 33.44 | 0.00 |
Minimum of Months | 0.58 | 0.00 |
Maximum of Months | 6.18 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.188673E+10 | 0.878232E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.202974E+10 | 0.673521E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.271042E+10 | 0.386647E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.425591E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.818910E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.871385E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.951245E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.949953E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.828047E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.703449E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.327302E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.256213E+10 | 0.466999E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.679478E+11 | 0.240540E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.188673E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.951245E+10 | 0.878232E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.109345E+11 | 0.298163E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.120968E+11 | 0.202742E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.159711E+11 | 0.120522E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.233819E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.394069E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.418037E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.451821E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.441375E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.385025E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.335468E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.181947E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.143756E+11 | 0.181028E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.337534E+12 | 0.802455E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.109345E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.451821E+11 | 0.298163E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.181935E+10 | 82098396.93 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.202536E+10 | 0.125155E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.232512E+10 | 0.127609E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.325543E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.553631E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.577635E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.633122E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.649849E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.594136E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.562657E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.328774E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.251742E+10 | 72270437.12 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.509407E+11 | 0.407133E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.181935E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.649849E+10 | 0.127609E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.127296E+10 | 0.310825E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.140831E+10 | 0.334711E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.159429E+10 | 0.417446E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.222710E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.427175E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.452652E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.507420E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.522792E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.472359E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.450921E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.243690E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.182998E+10 | 0.270373E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.391027E+11 | 0.133336E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.127296E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.522792E+10 | 0.417446E+09 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.129597E+10 | 0.233717E+10 | 0.711368E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.117341E+10 | 0.339861E+10 | 0.545552E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.131068E+10 | 0.552695E+10 | 0.313184E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129157E+10 | 0.117353E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.148153E+10 | 0.269151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.148961E+10 | 0.290017E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.158406E+10 | 0.320967E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.159138E+10 | 0.320937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.148043E+10 | 0.279170E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.146479E+10 | 0.225760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126214E+10 | 0.803410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130433E+10 | 0.506158E+10 | 0.378269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.167299E+11 | 0.206694E+12 | 0.194837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.117341E+10 | 0.233717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.159138E+10 | 0.320967E+11 | 0.711368E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.744104E+10 | 0.125823E+11 | 0.238530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.674001E+10 | 0.195185E+11 | 0.162194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.752914E+10 | 0.307255E+11 | 0.964179E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.724418E+10 | 0.592772E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.772557E+10 | 0.120037E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.790606E+10 | 0.128975E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.844432E+10 | 0.142202E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.832877E+10 | 0.138149E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.765617E+10 | 0.119923E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.774715E+10 | 0.986051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.711901E+10 | 0.410671E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.743220E+10 | 0.257381E+11 | 0.144822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.913136E+11 | 0.936799E+12 | 0.641964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.674001E+10 | 0.125823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.844432E+10 | 0.142202E+12 | 0.238530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.789888E+09 | 0.428008E+10 | 66499701.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.722953E+09 | 0.550090E+10 | 0.101375E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.810602E+09 | 0.624209E+10 | 0.103363E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.794076E+09 | 0.999806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.906094E+09 | 0.187479E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.917311E+09 | 0.196382E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.987148E+09 | 0.217960E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.101949E+10 | 0.224070E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.961726E+09 | 0.206447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.100371E+10 | 0.191225E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.830566E+09 | 0.102807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.822535E+09 | 0.713075E+10 | 58539054.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.105661E+11 | 0.165789E+12 | 0.329777E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.722953E+09 | 0.428008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.101949E+10 | 0.224070E+11 | 0.103363E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.605954E+09 | 0.275438E+10 | 0.251768E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.551491E+09 | 0.361036E+10 | 0.271116E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.614253E+09 | 0.401593E+10 | 0.338132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.595875E+09 | 0.658288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.683374E+09 | 0.146377E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.693823E+09 | 0.156631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.758091E+09 | 0.178281E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.786113E+09 | 0.183445E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.739835E+09 | 0.166428E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.774908E+09 | 0.155407E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.627428E+09 | 0.755883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.627183E+09 | 0.507262E+10 | 0.219002E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.805833E+10 | 0.128252E+12 | 0.108002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.551491E+09 | 0.275438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.786113E+09 | 0.183445E+11 | 0.338132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.129597E+10 | 0.00 | 0.00 | 0.00 | 0.590761E+09 | 0.00 | 0.878232E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.117341E+10 | 0.00 | 0.00 | 0.00 | 0.856328E+09 | 0.00 | 0.673521E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.131068E+10 | 0.00 | 0.00 | 0.00 | 0.139973E+10 | 0.00 | 0.386647E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129157E+10 | 0.00 | 0.00 | 0.00 | 0.296434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.148153E+10 | 0.00 | 0.00 | 0.00 | 0.670757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.148961E+10 | 0.00 | 0.00 | 0.00 | 0.722424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.158406E+10 | 0.00 | 0.00 | 0.00 | 0.792840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.159138E+10 | 0.00 | 0.00 | 0.00 | 0.790815E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.148043E+10 | 0.00 | 0.00 | 0.00 | 0.680004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.146479E+10 | 0.00 | 0.00 | 0.00 | 0.556970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126214E+10 | 0.00 | 0.00 | 0.00 | 0.201088E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130433E+10 | 0.00 | 0.00 | 0.00 | 0.125780E+10 | 0.00 | 0.466999E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.167299E+11 | 0.00 | 0.00 | 0.00 | 0.512179E+11 | 0.00 | 0.240540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.117341E+10 | 0.00 | 0.00 | 0.00 | 0.590761E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.159138E+10 | 0.00 | 0.00 | 0.00 | 0.792840E+10 | 0.00 | 0.878232E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.744104E+10 | 0.00 | 0.00 | 0.00 | 0.349350E+10 | 0.00 | 0.298163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.674001E+10 | 0.00 | 0.00 | 0.00 | 0.535682E+10 | 0.00 | 0.202742E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.752914E+10 | 0.00 | 0.00 | 0.00 | 0.844194E+10 | 0.00 | 0.120522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.724418E+10 | 0.00 | 0.00 | 0.00 | 0.161377E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.772557E+10 | 0.00 | 0.00 | 0.00 | 0.316814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.790606E+10 | 0.00 | 0.00 | 0.00 | 0.338977E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.844432E+10 | 0.00 | 0.00 | 0.00 | 0.367378E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.832877E+10 | 0.00 | 0.00 | 0.00 | 0.358088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.765617E+10 | 0.00 | 0.00 | 0.00 | 0.308463E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.774715E+10 | 0.00 | 0.00 | 0.00 | 0.257996E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.711901E+10 | 0.00 | 0.00 | 0.00 | 0.110757E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.743220E+10 | 0.00 | 0.00 | 0.00 | 0.694336E+10 | 0.00 | 0.181028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.913136E+11 | 0.00 | 0.00 | 0.00 | 0.246221E+12 | 0.00 | 0.802455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.674001E+10 | 0.00 | 0.00 | 0.00 | 0.349350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.844432E+10 | 0.00 | 0.00 | 0.00 | 0.367378E+11 | 0.00 | 0.298163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.789888E+09 | 0.00 | 0.00 | 0.00 | 0.102946E+10 | 0.00 | 82098396.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.722953E+09 | 0.00 | 0.00 | 0.00 | 0.130240E+10 | 0.00 | 0.125155E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.810602E+09 | 0.00 | 0.00 | 0.00 | 0.151452E+10 | 0.00 | 0.127609E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.794076E+09 | 0.00 | 0.00 | 0.00 | 0.246136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.906094E+09 | 0.00 | 0.00 | 0.00 | 0.463021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.917311E+09 | 0.00 | 0.00 | 0.00 | 0.485903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.987148E+09 | 0.00 | 0.00 | 0.00 | 0.534407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.101949E+10 | 0.00 | 0.00 | 0.00 | 0.547901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.961726E+09 | 0.00 | 0.00 | 0.00 | 0.497964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.100371E+10 | 0.00 | 0.00 | 0.00 | 0.462287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.830566E+09 | 0.00 | 0.00 | 0.00 | 0.245718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.822535E+09 | 0.00 | 0.00 | 0.00 | 0.169488E+10 | 0.00 | 72270437.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.105661E+11 | 0.00 | 0.00 | 0.00 | 0.403746E+11 | 0.00 | 0.407133E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.722953E+09 | 0.00 | 0.00 | 0.00 | 0.102946E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.101949E+10 | 0.00 | 0.00 | 0.00 | 0.547901E+10 | 0.00 | 0.127609E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.605954E+09 | 0.00 | 0.00 | 0.00 | 0.667004E+09 | 0.00 | 0.310825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.551491E+09 | 0.00 | 0.00 | 0.00 | 0.856818E+09 | 0.00 | 0.334711E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.614253E+09 | 0.00 | 0.00 | 0.00 | 0.980033E+09 | 0.00 | 0.417446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.595875E+09 | 0.00 | 0.00 | 0.00 | 0.163122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.683374E+09 | 0.00 | 0.00 | 0.00 | 0.358838E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.693823E+09 | 0.00 | 0.00 | 0.00 | 0.383270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.758091E+09 | 0.00 | 0.00 | 0.00 | 0.431611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.786113E+09 | 0.00 | 0.00 | 0.00 | 0.444181E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.739835E+09 | 0.00 | 0.00 | 0.00 | 0.398376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.774908E+09 | 0.00 | 0.00 | 0.00 | 0.373430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.627428E+09 | 0.00 | 0.00 | 0.00 | 0.180947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.627183E+09 | 0.00 | 0.00 | 0.00 | 0.120280E+10 | 0.00 | 0.270373E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.805833E+10 | 0.00 | 0.00 | 0.00 | 0.310444E+11 | 0.00 | 0.133336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.551491E+09 | 0.00 | 0.00 | 0.00 | 0.667004E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.786113E+09 | 0.00 | 0.00 | 0.00 | 0.444181E+10 | 0.00 | 0.417446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.328942E+10 | 0.266095E+09 | 0.00 | 1378059.34 | 14570134.07 | 0.330161E+09 | 0.969981E+09 | 0.00 | 0.25 |
February | 0.199188E+10 | 0.381662E+09 | 0.00 | 2364332.15 | 11086243.00 | 0.229968E+09 | 0.138004E+10 | 0.00 | 0.30 |
March | 0.156459E+10 | 0.918981E+09 | 0.00 | 2923633.71 | 357861.76 | 0.163148E+09 | 0.201848E+10 | 0.00 | 0.32 |
April | 0.212899E+09 | 0.214546E+10 | 0.00 | 3936164.07 | 1702699.35 | 0.00 | 0.185077E+10 | 0.00 | 0.37 |
May | 0.00 | 0.746736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 |
June | 0.00 | 0.853402E+10 | 0.00 | 14032.70 | 0.00 | 0.00 | 31180.00 | 0.00 | 0.21 |
July | 0.00 | 0.101730E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 |
August | 0.00 | 0.950305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 |
September | 0.00 | 0.801121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 |
October | 78760943.85 | 0.579534E+10 | 0.00 | 3815370.19 | 0.00 | 0.00 | 0.115972E+10 | 0.00 | 0.29 |
November | 0.662745E+09 | 0.166647E+10 | 0.00 | 5662022.26 | 2572866.76 | 0.00 | 0.293301E+10 | 0.00 | 0.41 |
December | 0.240658E+10 | 0.102249E+10 | 2973092.23 | 2304383.97 | 10350538.18 | 0.152430E+09 | 0.160624E+10 | 6404.54 | 0.28 |
Annual Sum or Average | 0.102069E+11 | 0.558852E+11 | 2973092.23 | 22397998.39 | 40640343.11 | 0.875706E+09 | 0.119183E+11 | 6404.54 | 0.27 |
Minimum of Months | 0.00 | 0.266095E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 |
Maximum of Months | 0.328942E+10 | 0.101730E+11 | 2973092.23 | 5662022.26 | 14570134.07 | 0.330161E+09 | 0.293301E+10 | 6404.54 | 0.41 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.243395E+11 | 0.240349E+10 | 0.00 | 10805874.34 | 49958660.83 | 0.130023E+09 | 0.790326E+10 | 0.00 | 0.44 |
February | 0.148100E+11 | 0.368836E+10 | 0.00 | 15218267.36 | 10203908.40 | 0.200246E+09 | 0.866376E+10 | 0.00 | 0.46 |
March | 0.125013E+11 | 0.773089E+10 | 0.00 | 19715184.18 | 32777068.80 | 87619104.43 | 0.107380E+11 | 0.00 | 0.48 |
April | 0.163150E+10 | 0.169627E+11 | 0.00 | 22389383.89 | 90774218.60 | 0.00 | 0.777461E+10 | 0.00 | 0.49 |
May | 0.00 | 0.557341E+11 | 0.00 | 0.00 | 0.514928E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
June | 872314.88 | 0.629405E+11 | 0.00 | 314753.77 | 0.513836E+09 | 0.00 | 73204.97 | 0.00 | 0.41 |
July | 0.00 | 0.746436E+11 | 0.00 | 0.00 | 0.613504E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
August | 0.00 | 0.695335E+11 | 0.00 | 0.00 | 0.532238E+09 | 0.00 | 0.00 | 0.00 | 0.41 |
September | 0.00 | 0.580827E+11 | 0.00 | 0.00 | 0.441352E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
October | 0.100139E+10 | 0.433521E+11 | 0.00 | 14345015.33 | 0.323407E+09 | 0.00 | 0.433082E+10 | 0.00 | 0.44 |
November | 0.542560E+10 | 0.123388E+11 | 0.00 | 29557370.20 | 88992852.57 | 0.00 | 0.122791E+11 | 0.00 | 0.51 |
December | 0.186449E+11 | 0.769391E+10 | 0.00 | 14837171.96 | 0.104613E+09 | 78449209.14 | 0.854747E+10 | 0.00 | 0.45 |
Annual Sum or Average | 0.783551E+11 | 0.415105E+12 | 0.00 | 0.127183E+09 | 0.331659E+10 | 0.496338E+09 | 0.602371E+11 | 0.00 | 0.44 |
Minimum of Months | 0.00 | 0.240349E+10 | 0.00 | 0.00 | 10203908.40 | 0.00 | 0.00 | 0.00 | 0.40 |
Maximum of Months | 0.243395E+11 | 0.746436E+11 | 0.00 | 29557370.20 | 0.613504E+09 | 0.200246E+09 | 0.122791E+11 | 0.00 | 0.51 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.936588E+09 | 0.559952E+09 | 0.00 | 8570824.78 | 559052.30 | 4502232.14 | 0.352877E+10 | 0.00 | 0.68 |
February | 0.687407E+09 | 0.807302E+09 | 0.00 | 5445389.48 | 0.00 | 24965792.50 | 0.226924E+10 | 0.00 | 0.65 |
March | 0.694341E+09 | 0.113723E+10 | 0.00 | 4997128.68 | 46178.16 | 35021872.87 | 0.209719E+10 | 0.00 | 0.64 |
April | 0.105629E+09 | 0.213930E+10 | 0.00 | 2771592.78 | 129400.67 | 0.00 | 0.948708E+09 | 0.00 | 0.58 |
May | 0.00 | 0.616909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
June | 0.00 | 0.685863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
July | 0.00 | 0.811832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
August | 0.00 | 0.771983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
September | 0.00 | 0.673510E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
October | 27984296.71 | 0.517138E+10 | 0.00 | 3194822.22 | 0.00 | 0.00 | 0.740481E+09 | 0.00 | 0.52 |
November | 0.130378E+09 | 0.182645E+10 | 0.00 | 8786825.72 | 0.00 | 0.00 | 0.244619E+10 | 0.00 | 0.74 |
December | 0.683828E+09 | 0.122448E+10 | 0.00 | 8398056.17 | 1395636.41 | 15424832.06 | 0.301468E+10 | 0.00 | 0.67 |
Annual Sum or Average | 0.326615E+10 | 0.484671E+11 | 0.00 | 42164639.83 | 2130267.54 | 79914729.57 | 0.150453E+11 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.559952E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
Maximum of Months | 0.936588E+09 | 0.811832E+10 | 0.00 | 8786825.72 | 1395636.41 | 35021872.87 | 0.352877E+10 | 0.00 | 0.74 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.162958E+10 | 0.422091E+09 | 0.00 | 3487600.95 | 1325086.10 | 67018922.81 | 0.167265E+10 | 0.00 | 0.52 |
February | 0.110728E+10 | 0.643691E+09 | 0.00 | 2345871.27 | 1372869.71 | 85130779.11 | 0.108827E+10 | 0.00 | 0.50 |
March | 0.108619E+10 | 0.895916E+09 | 0.00 | 2067066.84 | 1488503.20 | 0.147290E+09 | 0.888699E+09 | 0.00 | 0.51 |
April | 0.239483E+09 | 0.172313E+10 | 0.00 | 1617912.68 | 2554762.49 | 0.00 | 0.682215E+09 | 0.00 | 0.52 |
May | 0.00 | 0.563223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
June | 0.00 | 0.639712E+10 | 0.00 | 4656.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
July | 0.00 | 0.762884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
August | 0.00 | 0.725779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
September | 0.00 | 0.624952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
October | 86996293.25 | 0.488741E+10 | 0.00 | 1979187.41 | 0.00 | 0.00 | 0.447379E+09 | 0.00 | 0.47 |
November | 0.291098E+09 | 0.163178E+10 | 0.00 | 5541186.31 | 0.00 | 0.00 | 0.163453E+10 | 0.00 | 0.61 |
December | 0.127086E+10 | 0.106704E+10 | 0.00 | 4055123.84 | 2624825.75 | 91754873.39 | 0.147450E+10 | 0.00 | 0.53 |
Annual Sum or Average | 0.571148E+10 | 0.444366E+11 | 0.00 | 21098605.49 | 9366047.25 | 0.391195E+09 | 0.788823E+10 | 0.00 | 0.47 |
Minimum of Months | 0.00 | 0.422091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
Maximum of Months | 0.162958E+10 | 0.762884E+10 | 0.00 | 5541186.31 | 2624825.75 | 0.147290E+09 | 0.167265E+10 | 0.00 | 0.61 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |