Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Simulation Timestamp: 2020-06-03 19:11:32
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1470.93 | 641.21 | 641.21 |
Net Site Energy | 1470.93 | 641.21 | 641.21 |
Total Source Energy | 3723.17 | 1623.01 | 1623.01 |
Net Source Energy | 3723.17 | 1623.01 | 1623.01 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 352.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 115.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 422.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 60.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 228.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 96.01 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1021.93 | 449.00 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 352.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 115.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 422.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 60.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 194.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 228.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 96.01 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 210.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 150.34 | 195.73 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 445.48 | 195.73 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 210.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 150.34 | 195.73 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 84.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 445.48 | 195.73 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1021.932 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1021.932 | 100.00 |
Total On-Site and Utility Electric Sources | 1021.932 | 100.00 |
Total Electricity End Uses | 1021.932 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1600.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2010
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Latitude [deg] | 39.72 |
Longitude [deg] | -104.8 |
Elevation [m] | 1726.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 28.69 |
Skylight-Roof Ratio [%] | 1.25 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 7.5670 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 18.0834 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.0834 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.0834 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 9.6875 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.2979 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.2979 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 26-JUN-15:30 | 23-DEC-07:10 | - | - | - | 20-JAN-12:09 |
Heating | 0.00 | 234538.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 43766.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 31216.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10752.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 13099.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1860.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 98835.91 | 236398.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 234538.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 43766.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 31216.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10752.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 13099.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1860.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 382.64 | 0.00 | 0.00 | 0.00 |
Cooling | 367.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1336.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 191.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 616.39 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 725.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 104.07 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3236.46 | 486.71 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 166.80 | 0.00 | 0.00 | 0.00 |
Cooling | 160.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 582.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 83.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 316.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 45.37 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1410.84 | 212.17 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 166.80 | 0.00 | 0.00 | 0.00 |
Cooling | 160.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 582.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 83.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 268.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 316.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 45.37 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1410.84 | 212.17 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 2.07 |
CORE_RETAIL DIRECT AIR | 9.32 |
POINT_OF_SALE DIRECT AIR | 1.31 |
FRONT_RETAIL DIRECT AIR | 1.05 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 2.70 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 2.70 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 51066.96 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 47522.11 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 246936.73 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 31258.65 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 26406.10 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 2.07 | 2.07 | 2.07 | 2.07 | 2.10 | 2.10 | 1.00 | 0.983302 | 2.10 |
PSZ-AC:2 | 9.32 | 9.32 | 9.32 | 9.32 | 9.52 | 9.52 | 1.00 | 0.979065 | 9.52 |
PSZ-AC:3 | 1.31 | 1.31 | 1.31 | 1.31 | 1.32 | 1.32 | 1.00 | 0.990127 | 1.32 |
PSZ-AC:4 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.00 | 1.00 | 1.05 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 2.10 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 9.52 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.32 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 1.05 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 2.10 | 2.10 | 2.10 | 1.39 | 34797.50 | 47522.11 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 9.52 | 9.52 | 9.52 | 6.28 | 157880.02 | 246936.73 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.32 | 1.32 | 1.32 | 1.32 | 21846.16 | 31258.65 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 17340.03 | 26406.10 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 2.10 | 1.05 | 1.40 | 34797.55 | 34797.50 | 17398.75 | 17398.75 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 9.52 | 4.76 | 6.34 | 157540.47 | 157880.02 | 78940.01 | 78940.01 | 0.797865 | 0.797860 | 0.797860 | 0.797860 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.32 | 0.659865 | 0.879820 | 21846.22 | 21846.16 | 10923.08 | 10923.08 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 1.05 | 0.523755 | 0.698340 | 17340.01 | 17340.03 | 8670.01 | 8670.01 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.10 | 2249.36 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 9.52 | 15930.69 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.32 | 1461.15 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.05 | 1159.76 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 7.10 | 3.00 | -1.00 | 0.80 | -0.20 | 4.80 | 6.10 | 13.70 | 22.20 | 22.70 | 21.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 | 39.72 | -104.75 | -7.00 | 1726.00 | 82237 | 0.9774 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.95 | 23.70 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 7.567 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.637 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 18.083 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.313 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 18.083 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 39.603 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 18.083 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.313 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 9.688 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.688 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 2874.639 | 7.567 | 46.863 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2874.639 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 28942.124 | 18.083 | 111.990 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 28942.124 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2727.153 | 18.083 | 111.990 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2727.153 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2727.153 | 18.083 | 111.990 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2727.153 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 116.250 | 9.688 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 116.250 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 2.841 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.5534 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3520 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.640 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.8390000 | 2.8390000 | 2.8390000 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 2.8409091 | 2.8409091 | 2.8409091 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 9 | 0.29758781E-14 | -0.29065710E-15 | -0.16717921E-09 | -0.54082436E-16 |
25 | 8 | 0.24322757E-07 | 0.75510264E-13 | 0.40304845E-03 | -0.27655812E-09 |
26 | 7 | -0.12993629E-01 | 0.38338009E-08 | -0.24168191E-01 | 0.14774231E-03 |
27 | 6 | 0.42578349 | 0.13225368E-05 | 0.48945559 | -0.49886206E-02 |
28 | 5 | -5.3899404 | 0.49024379E-04 | -4.5744615 | 0.65656055E-01 |
29 | 4 | 33.884590 | 0.39840510E-03 | 21.960611 | -0.43383013 |
30 | 3 | -113.10176 | 0.86320527E-03 | -56.652426 | 1.5422922 |
31 | 2 | 198.98955 | 0.48301085E-03 | 78.818690 | -2.9302292 |
32 | 1 | -171.85079 | 0.51313109E-04 | -55.530381 | 2.7576150 |
33 | 0 | 57.057407 | 0.29052359E-06 | 15.514123 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 30 | 1 | VerySmooth | 2.672 | 0.394 | 0.315 | 0.401 |
2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 31 | 1 | VerySmooth | 5.779 | 0.490 | 0.326 | 0.491 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.40629E-002 | 0.31435 | 0.46917 | 0.46917 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11822 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.32532 | 0.12431 | 0.12431 | 0.49000 | 0.13099 | 0.16159 | 0.00000 | 0.84000 | 0.84000 | 0.30192 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1915 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2289.08 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.937 | 7.811E-002 | 2.576E-002 | 46.096 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 19686.24572 | 23623.49487 | 1.72251 | 2.06702 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 22.94800 | 5.43031E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 26000.05176 | 31200.06211 | 1.35565 | 1.62678 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 88596.89904 | 106316.27885 | 7.76482 | 9.31778 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 22.94800 | 5.43031E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 68389.41571 | 82067.29886 | 3.53094 | 4.23713 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 12307.80130 | 14769.36156 | 1.08891 | 1.30670 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 22.94800 | 5.43031E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 12709.62185 | 15251.54622 | 0.66455 | 0.79745 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 9629.47777 | 11555.37332 | 0.87293 | 1.04751 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 33.75200 | 5.43030E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 12709.62185 | 15251.54622 | 0.66455 | 0.79745 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90000 | 5.43030E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 42498.66403 | 50998.39684 | 2.24736 | 2.69683 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | -17.90000 | 9.55238E-004 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 24029.53 | 2.10212 | 2.10212 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 39282.45 | 1.62678 | 1.62678 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 119450.13 | 9.51702 | 9.51702 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 151554.00 | 4.23713 | 4.23713 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 16123.92 | 1.31973 | 1.31973 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 21724.46 | 0.79745 | 0.79745 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 13158.89 | 1.04751 | 1.04751 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 21724.46 | 0.79745 | 0.79745 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.06702 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 9.31778 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.30670 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.04751 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 2.69683 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 2.69683 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 51066.95984 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.06702 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.06702 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.06702 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.06702 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.10212 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.10212 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.98330 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 9.31778 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 9.31778 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 9.31778 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 9.31778 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 9.51702 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 9.51702 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.97906 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.30670 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.30670 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.30670 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.30670 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.31973 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.31973 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 0.99013 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.04751 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.04751 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.04751 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.04751 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04751 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04751 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 2.10212 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 9.51702 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.31973 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 1.04751 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.10212 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.10212 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.10212 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.10212 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.38740 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.10212 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.05106 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.40141 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 34797.55007 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 34797.50000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 17398.75000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17398.75000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 34797.50000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 47522.11368 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.10212 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2249.36449 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 47522.11368 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 9.51702 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 9.51702 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 9.51702 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 9.51702 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 6.28124 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 9.51702 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 4.75851 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 6.34468 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 157540.47343 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 157880.02000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 78940.01000 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 78940.01000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79786 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79786 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79786 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79786 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 157880.02000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 246936.73294 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 9.51702 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 15930.69220 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 246936.73294 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.31973 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.31973 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.31973 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.31973 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.31973 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.31973 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.65987 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.87982 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21846.21751 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21846.16000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10923.08000 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10923.08000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21846.16000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31258.64984 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.31973 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1461.14696 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31258.64984 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04751 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04751 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04751 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04751 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04751 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04751 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52376 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.69834 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17340.00993 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17340.03000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8670.01500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8670.01500 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17340.03000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26406.09990 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04751 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1159.76141 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26406.09990 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 33150.1 | 11.11 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 150421.2 | 12.40 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 20811.9 | 109.06 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 16519.1 | 151.99 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1571.79 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | N/A | 5.779 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | |
1 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R4C1 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
2 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R4C2 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
3 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R4C3 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
4 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R4C4 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
5 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C1 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
6 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C2 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
7 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C4 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
8 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C3 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
9 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C2 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
10 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C1 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
11 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C3 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
12 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C4 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
13 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R3C2 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
14 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R3C1 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
15 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R3C3 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A | |||
16 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R3C4 | Window5 Detailed Fenestration | N/A | N/A | 0.31 | 0.31 | * | N/A | N/A | 6.00E-002 | N/A |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 8 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 9.8136659573E-002 | 0.4074548638 | Pass | Pass | 4.6560203151E-002 | 0.1658060441 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 4.6397038531E-002 | 0.1984813439 | Pass | Pass | 0.2393163838 | 0.9262932725 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 0.1048297005 | 0.2337976898 | Pass | Pass | 5.6839820804E-002 | 0.1743137899 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 9.5733118491E-002 | 0.2814202436 | Pass | Pass | 0.1261960975 | 0.6387443773 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.2097856901 | 0.5760848207 | Pass | Pass | 0.1264563859 | 0.6021970091 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00 | -17.90 | Wetbulb [C] | 2.50 | 180.00 |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 14.80 | 15.00 | Wetbulb [C] | 3.60 | 30.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 1600.48 | 1571.79 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.49 | 1.49 | 0.31 | 0.00 | 1.79 | 1.79 | 5.779 | 0.490 | 0.491 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.672 | 0.394 | 0.401 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.672 | 0.394 | 0.401 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.47_SHGC_0.4 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.672 | 0.394 | 0.401 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 112.63 | 3.463 | 0.419 | 0.424 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 112.63 | 3.463 | 0.419 | 0.424 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 7.5670 | 379.89 | 2874.64 | LightsWired | BLDG_LIGHT_BACK_SCH | 63.14 | 168.00 | 62.27 | 0.0000 | Y | 33.60 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 18.0834 | 1600.48 | 28942.12 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 58.40 | 0.0000 | Y | 317.30 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 18.0834 | 150.81 | 2727.15 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 34.94 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 18.0834 | 150.81 | 2727.15 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 34.94 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 9.6875 | 12.00 | 116.25 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 57.54 | 168.00 | 56.76 | 0.0000 | Y | 1.24 |
Interior Lighting Total | 16.2979 | 2293.99 | 37387.32 | 422.03 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 28942.12 | 7235.53 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 28942.12 | 7235.53 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 316.30 | AstronomicalClock | - | 42.26 | 42.26 | 2.51 | |
EXTERIOR_LIGHTS_B | 4328.00 | AstronomicalClock | - | 83.67 | 71.25 | 57.88 | |
Exterior Lighting Total | 4644.30 | 60.39 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 34797.50 | 27791.37 | 7006.13 | 0.80 | 3.80 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 157880.02 | 125966.15 | 31913.87 | 0.80 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 21846.16 | 17447.65 | 4398.51 | 0.80 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17340.03 | 13848.79 | 3491.24 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 33150.1 | 11.11 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 150421.2 | 12.40 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 20811.9 | 109.06 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 16519.1 | 151.99 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 51066.96 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 47522.11 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 246936.73 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31258.65 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26406.10 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.58 | 622.50 | 2.70 | 2885.74 | 1070.05 | 1.00 | 1.26 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.10 | 2249.36 | 1070.05 | 1.00 | 1.31 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.61 | 1018.41 | 9.52 | 15930.69 | 1673.92 | 1.00 | 1.16 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.32 | 1461.15 | 1107.16 | 1.00 | 1.34 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.05 | 1159.76 | 1107.16 | 1.00 | 1.39 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 19686.25 | 23623.49 | 62.19 | 1.723 | 2.067 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.88 | 0.00834 | 22.95 | 0.00543 | 0.232 | 0.00 |
CORE_RETAIL | 88596.90 | 106316.28 | 66.43 | 7.765 | 9.318 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00802 | 22.95 | 0.00543 | 1.890 | 0.00 |
POINT_OF_SALE | 12307.80 | 14769.36 | 97.93 | 1.089 | 1.307 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00747 | 22.95 | 0.00543 | 0.178 | 0.00 |
FRONT_RETAIL | 9629.48 | 11555.37 | 76.62 | 0.873 | 1.048 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 23.89 | 23.89 | 0.00754 | 33.75 | 0.00543 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.20 | 100.00 | 0.00001 | 33.90 | 0.00543 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 26000.05 | 31200.06 | 82.13 | 1.356 | 1.627 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00787 | -17.90 | 0.00096 | 0.232 | 0.00 |
CORE_RETAIL | 68389.42 | 82067.30 | 51.28 | 3.531 | 4.237 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00787 | -17.90 | 0.00096 | 1.890 | 0.00 |
POINT_OF_SALE | 12709.62 | 15251.55 | 101.13 | 0.665 | 0.797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00792 | -17.90 | 0.00096 | 0.178 | 0.00 |
FRONT_RETAIL | 12709.62 | 15251.55 | 101.13 | 0.665 | 0.797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00792 | -17.90 | 0.00096 | 0.178 | 0.00 |
FRONT_ENTRY | 42498.66 | 50998.40 | 4249.87 | 2.247 | 2.697 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 21.11 | 21.00 | 0.00572 | -17.90 | 0.00096 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 2.10 | 2.10 | 1.63 | 1.63 | 2.1021 | 2.0670 | 2.1021 | 0.9833 | 1.0000 |
PSZ-AC:2 | 9.52 | 9.52 | 4.24 | 4.24 | 9.5170 | 9.3178 | 9.5170 | 0.9791 | 1.0000 |
PSZ-AC:3 | 1.32 | 1.32 | 0.80 | 0.80 | 1.3197 | 1.3067 | 1.3197 | 0.9901 | 1.0000 |
PSZ-AC:4 | 1.05 | 1.05 | 0.80 | 0.80 | 1.0475 | 1.0475 | 1.0475 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 51066.960 | 51066.960 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 51066.96 | 51066.96 | 2.696831 | 20.80 | 10.63 | 0.00569297 | 40.00 | 18.73 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00571800 | 30.1113 | 50998.40 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 17398.750 | 0.000 | 2.102120 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 17398.75 | 16432.85 | 2.102120 | 25.05 | 13.72 | 0.00745469 | 12.80 | 8.75 | 0.00700000 | 33.90 | 0.00543030 | 15.00 | 11.0159 | 23.88 | 0.00834125 | 36.7109 | 19686.25 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 47522.114 | 47522.114 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 47522.11 | 47522.11 | 2.102117 | 15.41 | 9.69 | 0.00688859 | 40.00 | 18.73 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 11.0159 | 21.11 | 0.00787337 | 41.0466 | 26000.05 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 78940.010 | 0.000 | 9.517020 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 78940.01 | 76924.86 | 9.517020 | 25.93 | 13.82 | 0.00721175 | 12.80 | 8.75 | 0.00700000 | 33.90 | 0.00543030 | 15.00 | 19.8614 | 23.89 | 0.00802230 | 35.3228 | 85138.37 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 246936.733 | 246936.733 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 246936.73 | 246936.73 | 9.517025 | 3.58 | 2.05 | 0.00478574 | 40.00 | 18.73 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 19.8614 | 21.11 | 0.00787084 | 41.0331 | 68389.42 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 10923.080 | 0.000 | 1.319730 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 10923.08 | 10700.09 | 1.319730 | 25.24 | 13.54 | 0.00716278 | 12.80 | 8.75 | 0.00700000 | 33.90 | 0.00543030 | 15.00 | 13.4960 | 23.89 | 0.00746878 | 32.9100 | 12131.91 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 31258.650 | 31258.650 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 31258.65 | 31258.65 | 1.319727 | 12.26 | 7.88 | 0.00636408 | 40.00 | 18.73 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 13.4960 | 21.11 | 0.00791955 | 41.2839 | 12709.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 8670.015 | 0.000 | 1.047510 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 8670.01 | 8472.47 | 1.047510 | 25.59 | 13.68 | 0.00718534 | 12.80 | 8.75 | 0.00700000 | 33.90 | 0.00543030 | 15.00 | 17.0032 | 23.89 | 0.00754475 | 33.2400 | 9629.09 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 26406.100 | 26406.100 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 26406.10 | 26406.10 | 1.047511 | 12.26 | 7.88 | 0.00636408 | 40.00 | 18.73 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 17.0032 | 21.11 | 0.00791955 | 41.2839 | 12709.62 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 51066.960 | 51066.960 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 2.696831 | 2.63598441 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 51066.96 | 51066.96 | 1.0000 | 2.63598441 | 2.696831 | 20.80 | 10.63 | 0.00569297 | 35355.6 | 40.00 | 18.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 51066.96 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 21.03 | 0.00571800 | 21.00 | 0.00571800 | 30.1113 | 50998.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17398.750 | 0.000 | 2.102120 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.6979 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 17398.75 | 16432.85 | 1.0000 | 2.05469115 | 2.102120 | 25.05 | 13.72 | 0.00745469 | 44160.6 | 12.80 | 8.75 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17398.75 | 33.90 | 0.00543030 | 15.00 | 0.23156651 | 11.0159 | 23.89 | 0.00772016 | 23.88 | 0.00834125 | 36.7109 | 19686.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 47522.114 | 47522.114 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.102117 | 2.05468815 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 47522.11 | 47522.11 | 1.0000 | 2.05468815 | 2.102117 | 15.41 | 9.69 | 0.00688859 | 32914.7 | 40.00 | 18.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 47522.11 | -17.90 | 0.00095524 | -17.90 | 0.23156651 | 11.0159 | 20.94 | 0.00787337 | 21.11 | 0.00787337 | 41.0466 | 26000.05 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 78940.010 | 0.000 | 9.517020 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.2463 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 78940.01 | 76924.86 | 1.0000 | 9.30229330 | 9.517020 | 25.93 | 13.82 | 0.00721175 | 44440.3 | 12.80 | 8.75 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 78940.01 | 33.90 | 0.00543030 | 15.00 | 1.89021192 | 19.8614 | 23.89 | 0.00766854 | 23.89 | 0.00802230 | 35.3228 | 85138.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 246936.733 | 246936.733 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 9.517025 | 9.30229791 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 246936.73 | 246936.73 | 1.0000 | 9.30229791 | 9.517025 | 3.58 | 2.05 | 0.00478574 | 15601.3 | 40.00 | 18.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 246936.73 | -17.90 | 0.00095524 | -17.90 | 1.89021192 | 19.8614 | 20.89 | 0.00787084 | 21.11 | 0.00787084 | 41.0331 | 68389.42 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 10923.080 | 0.000 | 1.319730 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.1552 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 10923.08 | 10700.09 | 1.0000 | 1.28995374 | 1.319730 | 25.24 | 13.54 | 0.00716278 | 43611.1 | 12.80 | 8.75 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10923.08 | 33.90 | 0.00543030 | 15.00 | 0.17811053 | 13.4960 | 23.89 | 0.00743307 | 23.89 | 0.00746878 | 32.9100 | 12131.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31258.650 | 31258.650 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.319727 | 1.28995053 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 31258.65 | 31258.65 | 1.0000 | 1.28995053 | 1.319727 | 12.26 | 7.88 | 0.00636408 | 28384.3 | 40.00 | 18.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31258.65 | -17.90 | 0.00095524 | -17.90 | 0.17811053 | 13.4960 | 20.94 | 0.00791955 | 21.11 | 0.00791955 | 41.2839 | 12709.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8670.015 | 0.000 | 1.047510 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.1972 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 8670.01 | 8472.47 | 1.0000 | 1.02387567 | 1.047510 | 25.59 | 13.68 | 0.00718534 | 44026.2 | 12.80 | 8.75 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8670.01 | 33.90 | 0.00543030 | 15.00 | 0.17811053 | 17.0032 | 23.89 | 0.00754490 | 23.89 | 0.00754475 | 33.2400 | 9629.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26406.100 | 26406.100 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.047511 | 1.02387705 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 26406.10 | 26406.10 | 1.0000 | 1.02387705 | 1.047511 | 12.26 | 7.88 | 0.00636408 | 28384.3 | 40.00 | 18.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26406.10 | -17.90 | 0.00095524 | -17.90 | 0.17811053 | 17.0032 | 20.94 | 0.00791955 | 21.11 | 0.00791955 | 41.2839 | 12709.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:1_OA_CONTROLLER | DifferentialDryBulb | 0.23 | 2.10 | - | |||
PSZ-AC:2_OA_CONTROLLER | DifferentialDryBulb | 1.89 | 9.52 | - | |||
PSZ-AC:3_OA_CONTROLLER | DifferentialDryBulb | 0.18 | 1.32 | - | |||
PSZ-AC:4_OA_CONTROLLER | DifferentialDryBulb | 0.18 | 1.05 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2117.50 | 3621.83 | 1588.00 |
CORE_RETAIL | 1580.83 | 3068.83 | 692.50 |
POINT_OF_SALE | 1733.17 | 2494.33 | 588.33 |
FRONT_RETAIL | 1724.17 | 2900.17 | 815.17 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 2753.17 | 3629.50 | 1600.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 45.33 | 0.67 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 17.33 | 0.00 | 0.00 |
POINT_OF_SALE | 21.50 | 29.00 | 0.00 | 0.00 |
FRONT_RETAIL | 31.17 | 5.67 | 0.00 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 51.83 | 46.67 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.44 | 61.34 | 2317.33 | 0.556 | 0.028 | 0.000 | 0.000 |
CORE_RETAIL | 128.26 | 258.43 | 9762.95 | 0.906 | 0.005 | 0.000 | 0.000 |
POINT_OF_SALE | 12.09 | 24.35 | 919.94 | 1.565 | 0.030 | 0.000 | 0.000 |
FRONT_RETAIL | 12.09 | 24.35 | 919.94 | 1.215 | 0.030 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.44 | 61.34 | 2317.33 | 0.354 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.26 | 258.43 | 9762.95 | 0.686 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.09 | 24.35 | 919.94 | 0.689 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.09 | 24.35 | 919.94 | 0.688 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
Electricity:Building | 616.66 | 3167.63 | 21-MAY-07:50 | 44140.05 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 83.46 | 599.86 | 01-JAN-00:10 | 5099.20 | 02-JAN-09:10 |
InteriorLights:Electricity | 422.03 | 1387.00 | 21-MAY-07:50 | 33387.34 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 33.60 | 143.73 | 01-JAN-00:10 | 2344.76 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 422.03 | 1387.00 | 21-MAY-07:50 | 33387.34 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 401.38 | 1733.89 | 21-MAY-07:50 | 30692.60 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 317.30 | 964.74 | 21-MAY-07:50 | 26047.91 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 87.72 | 619.23 | 01-JAN-00:10 | 5370.36 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 34.94 | 136.36 | 01-JAN-00:10 | 2454.44 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 42.86 | 208.83 | 01-JAN-00:10 | 2892.10 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 34.94 | 136.36 | 01-JAN-00:10 | 2454.44 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 1.24 | 5.81 | 01-JAN-00:10 | 85.79 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 1.24 | 5.81 | 01-JAN-00:10 | 85.79 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 194.63 | 1780.63 | 01-JAN-00:10 | 10752.72 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.86 | 456.13 | 01-JAN-00:10 | 2754.45 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 194.63 | 1780.63 | 01-JAN-00:10 | 10752.72 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.07 | 769.15 | 01-JAN-00:10 | 4644.69 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.78 | 482.87 | 01-JAN-00:10 | 2915.92 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.92 | 72.48 | 01-JAN-00:10 | 437.66 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
ElectricityPurchased:Plant | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
Cogeneration:ElectricityPurchased | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
ElectricityNet:Plant | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
Cogeneration:ElectricityNet | 1021.93 | 3408.81 | 07-MAY-06:20 | 98835.91 | 26-JUN-15:30 |
Electricity:HVAC | 344.88 | 0.00 | 01-JAN-00:10 | 58577.42 | 26-JUN-15:00 |
Fans:Electricity | 228.99 | 0.00 | 01-JAN-00:10 | 17924.28 | 23-DEC-07:20 |
General:Fans:Electricity | 228.99 | 0.00 | 01-JAN-00:10 | 17924.28 | 23-DEC-07:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 115.89 | 0.00 | 01-JAN-00:10 | 45116.02 | 26-JUN-15:00 |
ExteriorLights:Electricity | 60.39 | 0.00 | 01-JAN-07:30 | 4644.30 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 60.39 | 0.00 | 01-JAN-07:30 | 4644.30 | 01-JAN-06:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 449.00 | 1860.00 | 05-JAN-21:10 | 236398.04 | 23-DEC-07:10 |
Gas:Plant | 96.01 | 1860.00 | 05-JAN-05:40 | 5139.91 | 16-FEB-12:20 |
WaterSystems:Gas | 96.01 | 1860.00 | 05-JAN-05:40 | 5139.91 | 16-FEB-12:20 |
Water Heater:WaterSystems:Gas | 96.01 | 1860.00 | 05-JAN-05:40 | 5139.91 | 16-FEB-12:20 |
Gas:HVAC | 352.99 | 0.00 | 01-JAN-00:10 | 234538.04 | 23-DEC-07:10 |
Heating:Gas | 352.99 | 0.00 | 01-JAN-00:10 | 234538.04 | 23-DEC-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 20-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1418.86 | 0.00 | 01-JAN-00:10 | 297625.76 | 23-DEC-07:10 |
EnergyTransfer:Building | 714.77 | 0.00 | 01-JAN-00:10 | 115061.22 | 23-DEC-06:10 |
EnergyTransfer:Zone:BACK_SPACE | 89.29 | 0.00 | 01-JAN-00:10 | 43687.88 | 24-DEC-07:20 |
Heating:EnergyTransfer | 148.88 | 0.00 | 01-JAN-00:10 | 115061.22 | 23-DEC-06:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 34.68 | 0.00 | 01-JAN-00:10 | 43687.88 | 24-DEC-07:20 |
Cooling:EnergyTransfer | 565.89 | 0.00 | 01-JAN-00:10 | 82276.02 | 16-AUG-15:00 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 54.61 | 0.00 | 01-JAN-00:10 | 12623.27 | 01-JUL-22:40 |
EnergyTransfer:Zone:CORE_RETAIL | 412.54 | 0.00 | 01-JAN-00:10 | 73076.31 | 23-DEC-07:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 22.24 | 0.00 | 01-JAN-00:10 | 70716.28 | 21-DEC-06:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 390.31 | 0.00 | 01-JAN-00:10 | 61316.64 | 14-SEP-21:00 |
EnergyTransfer:Zone:POINT_OF_SALE | 80.08 | 0.00 | 01-JAN-00:10 | 18054.79 | 23-DEC-05:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 6.20 | 0.00 | 01-JAN-00:10 | 18054.79 | 23-DEC-05:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 73.88 | 0.00 | 01-JAN-00:10 | 12177.59 | 28-SEP-13:30 |
EnergyTransfer:Zone:FRONT_RETAIL | 57.39 | 0.00 | 01-JAN-00:10 | 19092.73 | 23-DEC-05:20 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 10.30 | 0.00 | 01-JAN-00:10 | 19092.73 | 23-DEC-05:20 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 47.09 | 0.00 | 01-JAN-00:10 | 10154.31 | 28-SEP-13:30 |
EnergyTransfer:Zone:FRONT_ENTRY | 75.46 | 0.00 | 01-JAN-00:10 | 47158.02 | 21-DEC-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 75.46 | 0.00 | 01-JAN-00:10 | 47158.02 | 21-DEC-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 704.09 | 0.00 | 01-JAN-00:10 | 187630.43 | 23-DEC-07:10 |
HeatingCoils:EnergyTransfer | 282.39 | 0.00 | 01-JAN-00:10 | 187630.43 | 23-DEC-07:10 |
CoolingCoils:EnergyTransfer | 421.70 | 0.00 | 01-JAN-00:10 | 132367.42 | 26-JUN-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 34.678 | -54.612 | 0.000 | 0.000 | 39.493 | 33.603 | 49.857 | 0.000 | 0.000 | 0.323 | 0.001 | 0.000 | 0.000 | 0.000 | -14.938 | -88.404 |
CORE_RETAIL | 0.000 | 0.000 | 22.235 | -390.307 | 0.000 | 0.000 | 164.808 | 317.304 | 84.072 | 53.165 | 0.000 | 0.264 | 0.000 | 0.000 | -40.985 | 0.000 | -13.057 | -197.498 |
POINT_OF_SALE | 0.000 | 0.000 | 6.203 | -73.879 | 0.000 | 0.000 | 15.013 | 34.941 | 52.780 | 48.689 | 0.000 | 0.140 | 0.000 | 0.000 | -26.216 | 0.000 | -6.932 | -50.739 |
FRONT_RETAIL | 0.000 | 0.000 | 10.299 | -47.089 | 0.000 | 0.000 | 15.299 | 34.941 | 7.922 | 48.814 | 0.000 | 0.140 | 0.001 | 0.000 | -25.560 | 0.000 | -6.714 | -38.051 |
FRONT_ENTRY | 75.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.239 | 0.000 | 9.806 | 0.000 | 0.644 | 0.000 | 0.000 | -5.208 | 0.000 | -78.999 | -2.947 |
Total Facility | 75.465 | 0.000 | 73.416 | -565.888 | 0.000 | 0.000 | 234.613 | 422.027 | 194.630 | 160.474 | 0.000 | 1.512 | 0.002 | 0.000 | -97.969 | 0.000 | -120.641 | -377.639 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 17-AUG-20:53 | 0.00 | 0.00 | 0.00 | -37379.83 | 0.00 | 0.00 | 0.00 | 574.93 | 608.18 | 0.00 | 0.00 | 0.00 | 36412.62 | 0.00 | -0.00 | 0.00 | -215.89 | 0.00 |
CORE_RETAIL | 14-JUL-00:51 | 0.00 | 0.00 | 0.00 | -167492.97 | 0.00 | 0.00 | 0.00 | 1447.11 | 1025.54 | 0.00 | 0.00 | 0.00 | 166728.35 | 0.00 | -1370.65 | 0.00 | -337.37 | 0.00 |
POINT_OF_SALE | 15-OCT-18:09 | 0.00 | 0.00 | 0.00 | -30869.63 | 0.00 | 0.00 | 0.00 | 136.36 | 482.87 | 0.00 | 0.00 | 0.00 | 31827.78 | 0.00 | -1425.42 | 0.00 | -151.95 | 0.00 |
FRONT_RETAIL | 14-SEP-21:02 | 0.00 | 0.00 | 0.00 | -20659.43 | 0.00 | 0.00 | 0.00 | 136.36 | 96.63 | 0.00 | 0.00 | 0.00 | 21747.96 | 0.00 | -1030.36 | 0.00 | -291.15 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 25-JUN-23:31 | 0.00 | 0.00 | 0.00 | -213987.75 | 0.00 | 0.00 | 0.00 | 1869.37 | 1780.63 | 0.00 | 0.00 | 0.00 | 214077.55 | 0.00 | -2808.14 | 0.00 | -931.65 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 05-FEB-07:41 | 0.00 | 0.00 | 50503.31 | 0.00 | 0.00 | 0.00 | 0.00 | 143.73 | 456.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1649.90 | -49453.27 |
CORE_RETAIL | 23-DEC-05:01 | 0.00 | 0.00 | 255102.52 | 0.00 | 0.00 | 0.00 | 0.00 | 1447.11 | 769.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4625.30 | 0.00 | -2875.11 | -249818.37 |
POINT_OF_SALE | 23-DEC-05:41 | 0.00 | 0.00 | 33227.81 | 0.00 | 0.00 | 0.00 | 0.00 | 136.36 | 482.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3256.02 | 0.00 | -1686.98 | -28904.04 |
FRONT_RETAIL | 20-DEC-05:31 | 0.00 | 0.00 | 27999.50 | 0.00 | 0.00 | 0.00 | 0.00 | 136.36 | 96.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2898.53 | 0.00 | -1306.99 | -24026.97 |
FRONT_ENTRY | 21-DEC-18:00 | 47157.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.79 | 0.00 | 0.00 | 0.00 | 0.00 | 57.36 | 0.00 | -731.88 | 0.00 | -46568.94 | 0.00 |
Total Facility | 22-DEC-05:01 | 6120.99 | 0.00 | 361683.77 | 0.00 | 0.00 | 0.00 | 0.00 | 1869.37 | 2374.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -10969.89 | 0.00 | -2688.83 | -358389.57 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.0670 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.1021 | 0.1102 | 1.0000 | 0.2316 | 0.1102 | ||
PSZ-AC:2 | 9.3178 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 9.5170 | 0.1986 | 1.0000 | 1.8902 | 0.1986 | ||
PSZ-AC:3 | 1.3067 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.3197 | 0.1350 | 1.0000 | 0.1781 | 0.1350 | ||
PSZ-AC:4 | 1.0475 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0475 | 0.1700 | 1.0000 | 0.1781 | 0.1700 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.0670 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.0670 | 1.0000 | 1.0000 | 0.2316 | 0.1120 | ||
PSZ-AC:2 | 9.3178 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 9.3178 | 1.0000 | 1.0000 | 1.8902 | 0.2029 | ||
PSZ-AC:3 | 1.3067 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.3067 | 1.0000 | 1.0000 | 0.1781 | 0.1363 | ||
PSZ-AC:4 | 1.0475 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0475 | 1.0000 | 1.0000 | 0.1781 | 0.1700 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.0670 | 2.0670 | 2.0670 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 9.3178 | 9.3178 | 9.3178 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.3067 | 1.3067 | 1.3067 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0475 | 1.0475 | 1.0475 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.0670 | 2.1021 | 2.0670 | 2.0670 | 0.2316 | 1.0000 |
PSZ-AC:2 | 9.3178 | 9.5170 | 9.3178 | 9.3178 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.3067 | 1.3197 | 1.3067 | 1.3067 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0475 | 1.0475 | 1.0475 | 1.0475 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.0670 | 2.0670 | 2.0670 | 0.2316 | 0.1423 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 9.3178 | 9.3178 | 9.3178 | 1.8902 | 0.4461 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.3067 | 1.3067 | 1.3067 | 0.1781 | 0.2233 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0475 | 1.0475 | 1.0475 | 0.1781 | 0.2233 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.0670 | 2.0670 | 2.0670 | 2.0670 | 0.2316 | 1.0000 |
PSZ-AC:2 | 9.3178 | 9.3178 | 9.3178 | 9.3178 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.3067 | 1.3067 | 1.3067 | 1.3067 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0475 | 1.0475 | 1.0475 | 1.0475 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:32
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 352.99 | 234538.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 115.89 | 45116.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 422.03 | 33387.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 60.39 | 4644.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 194.63 | 10752.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 228.99 | 17924.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 96.01 | 5139.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 194.63 | 1021.93 |
Natural Gas | 0.00 | 449.00 |
Additional | 0.00 | 0.00 |
Total | 194.63 | 1470.93 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 183.97 |
Space Heating | 0.00 |
Space Cooling | 50.52 |
Fans (All) | 99.82 |
Service Water Heating | 0.00 |
Receptacle Equipment | 84.84 |
Miscellaneous (All) | 445.48 |
Subtotal | 445.48 |
Natural Gas [MJ/m2] | |
Space Heating | 153.88 |
Service Water Heating | 41.85 |
Miscellaneous (All) | 195.73 |
Subtotal | 195.73 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 28.69 |
Space Heating | 24.00 |
Space Cooling | 7.88 |
Fans (All) | 15.57 |
Service Water Heating | 6.53 |
Receptacle Equipment | 13.23 |
Miscellaneous | 4.11 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3292. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3001. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4559. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_SETBACK | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
HTGSETP_SCH_PSZ_AC_2 | CORE_RETAIL DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2010
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.634870E+11 |
February | 0.000 | 0.658852E+11 |
March | 0.000 | 0.431566E+11 |
April | 0.000 | 0.316752E+11 |
May | 0.000 | 0.270534E+10 |
June | 0.000 | 9317324.730 |
July | 0.000 | 69180.194 |
August | 0.000 | 2039083.169 |
September | 0.000 | 0.547280E+09 |
October | 0.000 | 0.226462E+11 |
November | 0.000 | 0.399372E+11 |
December | 0.000 | 0.829388E+11 |
Annual Sum or Average | 0.352990E+12 | |
Minimum of Months | 0.000 | 69180.194 |
Maximum of Months | 0.000 | 0.829388E+11 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.681301E+09 | 2793.54 | 26-JAN-18:05 | 5.00 | 1.67 | 0.170957E+10 | 2431.09 | 20-JAN-15:39 | 18.67 | 7.27 |
February | 0.539813E+09 | 3109.05 | 28-FEB-15:20 | 3.67 | 3.02 | 0.154035E+10 | 2403.10 | 18-FEB-15:09 | 18.83 | 7.87 |
March | 0.124784E+10 | 4958.80 | 15-MAR-14:50 | 20.17 | 5.79 | 0.188013E+10 | 2451.21 | 10-MAR-15:09 | 17.00 | 4.95 |
April | 0.147603E+10 | 4273.45 | 21-APR-14:10 | 14.83 | 5.48 | 0.182027E+10 | 2451.23 | 13-APR-14:20 | 13.67 | 9.13 |
May | 0.391053E+10 | 7741.16 | 18-MAY-14:50 | 23.17 | 11.53 | 0.215440E+10 | 2451.29 | 24-MAY-14:00 | 18.00 | 11.48 |
June | 0.106932E+11 | 36717.30 | 28-JUN-00:31 | 19.40 | 10.07 | 0.220115E+10 | 2451.39 | 20-JUN-14:09 | 23.67 | 16.46 |
July | 0.108707E+11 | 35210.91 | 08-JUL-21:25 | 20.50 | 10.58 | 0.218693E+10 | 2451.33 | 25-JUL-14:50 | 21.00 | 16.07 |
August | 0.110898E+11 | 37380.59 | 17-AUG-20:53 | 19.00 | 9.33 | 0.228060E+10 | 2451.40 | 04-AUG-14:00 | 23.00 | 16.92 |
September | 0.871963E+10 | 37084.60 | 07-SEP-20:17 | 19.20 | 9.82 | 0.214531E+10 | 2452.13 | 30-SEP-15:09 | 17.20 | 13.64 |
October | 0.319713E+10 | 7685.40 | 11-OCT-14:40 | 26.33 | 9.51 | 0.197610E+10 | 2451.22 | 07-OCT-11:20 | 21.67 | 9.29 |
November | 0.151362E+10 | 4112.75 | 10-NOV-18:30 | -1.0 | -1.0 | 0.172264E+10 | 2451.23 | 06-NOV-15:09 | 20.17 | 6.52 |
December | 0.671848E+09 | 3968.41 | 07-DEC-16:35 | -1.7 | -5.8 | 0.170730E+10 | 2451.25 | 02-DEC-15:20 | 20.67 | 7.30 |
Annual Sum or Average | 0.546114E+11 | 0.233247E+11 | ||||||||
Minimum of Months | 0.539813E+09 | 2793.54 | -1.7 | -5.8 | 0.154035E+10 | 2403.10 | 13.67 | 4.95 | ||
Maximum of Months | 0.110898E+11 | 37380.59 | 26.33 | 11.53 | 0.228060E+10 | 2452.13 | 23.67 | 16.92 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.168006E+11 | 52913.07 | 15-JAN-09:05 | -10.5 | -11.1 | 0.743074E+10 | 10327.17 | 20-JAN-15:50 | 18.33 | 7.37 |
February | 0.159433E+11 | 50081.54 | 02-FEB-07:05 | -9.7 | -9.7 | 0.670145E+10 | 10327.02 | 18-FEB-14:00 | 19.00 | 7.95 |
March | 0.229770E+11 | 101660.86 | 14-MAR-20:25 | 14.50 | 4.39 | 0.818533E+10 | 10326.80 | 07-MAR-15:09 | 15.83 | 4.68 |
April | 0.221742E+11 | 46477.99 | 17-APR-06:05 | -7.7 | -8.4 | 0.791634E+10 | 10327.07 | 13-APR-14:20 | 13.67 | 9.13 |
May | 0.328287E+11 | 127857.14 | 10-MAY-21:01 | 20.33 | 7.89 | 0.921627E+10 | 10327.46 | 24-MAY-14:00 | 18.00 | 11.48 |
June | 0.560915E+11 | 162075.82 | 06-JUN-00:51 | 18.30 | 10.54 | 0.927393E+10 | 10327.72 | 20-JUN-14:09 | 23.67 | 16.46 |
July | 0.544955E+11 | 167491.94 | 14-JUL-00:51 | 18.00 | 9.26 | 0.921346E+10 | 10327.47 | 25-JUL-14:39 | 22.00 | 16.16 |
August | 0.566456E+11 | 167044.76 | 31-AUG-23:51 | 18.50 | 9.79 | 0.960772E+10 | 10328.70 | 16-AUG-14:20 | 36.67 | 16.26 |
September | 0.465414E+11 | 157344.39 | 29-SEP-22:50 | 19.72 | 8.56 | 0.903813E+10 | 10331.34 | 30-SEP-15:09 | 17.20 | 13.64 |
October | 0.295740E+11 | 52001.96 | 30-OCT-06:05 | -10.0 | -10.0 | 0.842582E+10 | 10326.99 | 07-OCT-11:20 | 21.67 | 9.29 |
November | 0.213319E+11 | 50085.66 | 29-NOV-07:05 | -10.8 | -10.8 | 0.744405E+10 | 10326.95 | 06-NOV-15:09 | 20.17 | 6.52 |
December | 0.149048E+11 | 52885.57 | 19-DEC-07:05 | -16.8 | -16.9 | 0.739004E+10 | 10327.09 | 02-DEC-12:20 | 20.33 | 6.98 |
Annual Sum or Average | 0.390309E+12 | 0.998433E+11 | ||||||||
Minimum of Months | 0.149048E+11 | 46477.99 | -16.8 | -16.9 | 0.670145E+10 | 10326.80 | 13.67 | 4.68 | ||
Maximum of Months | 0.566456E+11 | 167491.94 | 20.33 | 10.54 | 0.960772E+10 | 10331.34 | 36.67 | 16.46 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.441245E+10 | 9332.50 | 20-JAN-13:50 | 21.00 | 6.93 | 0.807488E+09 | 973.17 | 20-JAN-15:00 | 18.00 | 7.46 |
February | 0.351478E+10 | 9066.21 | 18-FEB-14:00 | 20.00 | 7.70 | 0.717854E+09 | 973.09 | 17-FEB-15:09 | 14.83 | 6.90 |
March | 0.400137E+10 | 9406.38 | 15-MAR-13:30 | 20.50 | 5.98 | 0.829140E+09 | 973.08 | 25-MAR-15:00 | 6.00 | 3.52 |
April | 0.289304E+10 | 6441.95 | 21-APR-13:30 | 15.50 | 6.01 | 0.790245E+09 | 973.10 | 29-APR-11:20 | 9.33 | 8.37 |
May | 0.483791E+10 | 24021.91 | 17-MAY-21:20 | 17.33 | 8.52 | 0.878879E+09 | 973.16 | 24-MAY-14:00 | 18.00 | 11.48 |
June | 0.873636E+10 | 23547.00 | 12-JUN-23:31 | 18.07 | 9.32 | 0.873993E+09 | 973.22 | 20-JUN-14:09 | 23.67 | 16.46 |
July | 0.914332E+10 | 23537.17 | 07-JUL-02:61 | 18.00 | 9.70 | 0.868307E+09 | 973.21 | 29-JUL-13:00 | 23.00 | 17.55 |
August | 0.101612E+11 | 24490.65 | 17-AUG-01:43 | 15.17 | 6.54 | 0.905526E+09 | 973.23 | 04-AUG-14:00 | 23.00 | 16.92 |
September | 0.995027E+10 | 24624.90 | 26-SEP-20:10 | 15.50 | 5.04 | 0.854778E+09 | 973.68 | 30-SEP-15:09 | 17.20 | 13.64 |
October | 0.683338E+10 | 30869.93 | 15-OCT-18:09 | 9.67 | 1.63 | 0.825176E+09 | 973.10 | 21-OCT-10:20 | 9.00 | 4.13 |
November | 0.539939E+10 | 28091.28 | 05-NOV-19:02 | 12.33 | 3.04 | 0.787753E+09 | 973.09 | 25-NOV-11:20 | 12.00 | 4.62 |
December | 0.399612E+10 | 8963.41 | 02-DEC-13:40 | 21.00 | 7.10 | 0.785086E+09 | 973.14 | 14-DEC-15:39 | 14.00 | 4.64 |
Annual Sum or Average | 0.738796E+11 | 0.992423E+10 | ||||||||
Minimum of Months | 0.289304E+10 | 6441.95 | 9.67 | 1.63 | 0.717854E+09 | 973.08 | 6.00 | 3.52 | ||
Maximum of Months | 0.101612E+11 | 30869.93 | 21.00 | 9.70 | 0.905526E+09 | 973.68 | 23.67 | 17.55 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.266961E+10 | 6902.20 | 20-JAN-14:00 | 21.00 | 6.93 | 0.762581E+09 | 973.15 | 20-JAN-15:00 | 18.00 | 7.46 |
February | 0.213569E+10 | 6696.16 | 18-FEB-14:10 | 19.83 | 7.75 | 0.680830E+09 | 973.09 | 18-FEB-15:09 | 18.83 | 7.87 |
March | 0.226117E+10 | 7217.67 | 15-MAR-13:30 | 20.50 | 5.98 | 0.788139E+09 | 973.08 | 03-MAR-15:00 | 10.00 | 1.70 |
April | 0.135695E+10 | 4171.00 | 21-APR-13:30 | 15.50 | 6.01 | 0.743061E+09 | 973.10 | 08-APR-10:50 | 14.83 | 4.54 |
May | 0.245279E+10 | 4816.24 | 18-MAY-14:40 | 23.33 | 11.48 | 0.859224E+09 | 973.14 | 24-MAY-14:00 | 18.00 | 11.48 |
June | 0.575235E+10 | 18086.01 | 28-JUN-00:06 | 19.40 | 10.23 | 0.873745E+09 | 973.19 | 20-JUN-14:09 | 23.67 | 16.46 |
July | 0.609712E+10 | 18285.59 | 13-JUL-22:39 | 19.00 | 9.12 | 0.868146E+09 | 973.17 | 27-JUL-14:00 | 18.00 | 14.77 |
August | 0.699994E+10 | 18911.52 | 16-AUG-23:46 | 18.33 | 9.13 | 0.905380E+09 | 973.19 | 04-AUG-14:00 | 23.00 | 16.92 |
September | 0.701492E+10 | 20661.36 | 14-SEP-21:02 | 14.80 | 6.09 | 0.852062E+09 | 973.56 | 30-SEP-15:09 | 17.20 | 13.64 |
October | 0.451822E+10 | 20604.87 | 08-OCT-18:10 | 13.67 | 7.19 | 0.806189E+09 | 973.10 | 21-OCT-10:20 | 9.00 | 4.13 |
November | 0.348198E+10 | 8617.18 | 07-NOV-13:50 | 21.67 | 7.26 | 0.752493E+09 | 973.10 | 25-NOV-11:20 | 12.00 | 4.62 |
December | 0.234887E+10 | 6628.45 | 02-DEC-14:30 | 21.50 | 7.49 | 0.746700E+09 | 973.11 | 14-DEC-15:30 | 14.50 | 4.61 |
Annual Sum or Average | 0.470896E+11 | 0.963855E+10 | ||||||||
Minimum of Months | 0.135695E+10 | 4171.00 | 13.67 | 5.98 | 0.680830E+09 | 973.08 | 9.00 | 1.70 | ||
Maximum of Months | 0.701492E+10 | 20661.36 | 23.33 | 11.48 | 0.905380E+09 | 973.56 | 23.67 | 16.92 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 | -1.6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 | -1.6 |
February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 | -5.3 | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 | -5.3 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.09 | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.09 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.25 | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.25 |
July | 0.00 | 0.00 | 01-JUL-00:01 | 22.27 | 10.88 | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 | 10.88 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.42 | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.42 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 18.18 | 10.63 | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 | 10.63 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.02 | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.02 |
November | 0.00 | 0.00 | 01-NOV-00:05 | -5.7 | -5.7 | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 | -5.7 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 | -0.3 | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 | -0.3 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -5.7 | -5.7 | 0.00 | 0.00 | -5.7 | -5.7 | ||
Maximum of Months | 0.00 | 0.00 | 22.27 | 15.42 | 0.00 | 0.00 | 22.27 | 15.42 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.660209E+10 | 49391.12 | 03-JAN-05:42 | -7.0 |
February | 0.706825E+10 | 50503.09 | 05-FEB-07:41 | -8.0 |
March | 0.461895E+10 | 49483.72 | 29-MAR-04:42 | -7.0 |
April | 0.325339E+10 | 49206.95 | 05-APR-04:42 | 0.00 |
May | 0.409530E+09 | 48399.42 | 03-MAY-04:01 | 1.83 |
June | 31041137.01 | 1093.72 | 27-JUN-05:07 | 18.17 |
July | 27404132.00 | 1084.61 | 27-JUL-05:07 | 19.17 |
August | 26957252.76 | 1183.69 | 20-AUG-07:05 | 21.00 |
September | 51044787.28 | 8737.84 | 22-SEP-05:02 | -1.7 |
October | 0.140109E+10 | 48720.57 | 31-OCT-04:12 | -8.0 |
November | 0.320749E+10 | 50331.31 | 01-NOV-04:41 | -3.0 |
December | 0.798093E+10 | 49629.01 | 24-DEC-07:11 | -18.7 |
Annual Sum or Average | 0.346782E+11 | |||
Minimum of Months | 26957252.76 | 1084.61 | -18.7 | |
Maximum of Months | 0.798093E+10 | 50503.09 | 21.00 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.405371E+10 | 251926.70 | 16-JAN-08:61 | -8.8 |
February | 0.450243E+10 | 253323.10 | 06-FEB-06:01 | -10.0 |
March | 0.233012E+10 | 250102.36 | 19-MAR-07:02 | -15.2 |
April | 0.161691E+10 | 250330.28 | 17-APR-05:02 | -8.0 |
May | 0.481688E+09 | 16851.13 | 01-MAY-06:05 | 6.33 |
June | 88440237.70 | 7818.23 | 02-JUN-05:03 | 13.90 |
July | 98068758.79 | 7698.30 | 14-JUL-05:05 | 16.33 |
August | 0.116385E+09 | 7988.50 | 27-AUG-07:03 | 16.17 |
September | 0.161182E+09 | 7894.03 | 01-SEP-05:03 | 12.20 |
October | 0.102434E+10 | 209430.41 | 31-OCT-05:02 | -8.2 |
November | 0.193959E+10 | 251802.02 | 30-NOV-06:01 | -12.0 |
December | 0.582270E+10 | 255102.59 | 23-DEC-05:01 | -21.4 |
Annual Sum or Average | 0.222356E+11 | |||
Minimum of Months | 88440237.70 | 7698.30 | -21.4 | |
Maximum of Months | 0.582270E+10 | 255102.59 | 16.33 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.733503E+09 | 31328.92 | 05-JAN-05:01 | -17.0 |
February | 0.123619E+10 | 32405.71 | 05-FEB-07:41 | -8.0 |
March | 0.102367E+10 | 31480.15 | 19-MAR-06:01 | -13.6 |
April | 0.820449E+09 | 31348.25 | 17-APR-04:01 | -8.0 |
May | 0.201503E+09 | 31314.54 | 03-MAY-04:01 | 1.83 |
June | 13998223.94 | 7196.60 | 30-JUN-04:10 | 19.50 |
July | 7754569.68 | 1551.66 | 25-JUL-05:05 | 17.33 |
August | 8980334.14 | 1766.27 | 17-AUG-05:03 | 12.00 |
September | 23125587.61 | 3562.17 | 03-SEP-06:50 | 19.40 |
October | 0.356153E+09 | 31336.45 | 31-OCT-04:01 | -8.0 |
November | 0.512552E+09 | 32360.64 | 01-NOV-04:41 | -3.0 |
December | 0.126536E+10 | 33227.62 | 23-DEC-05:41 | -21.9 |
Annual Sum or Average | 0.620325E+10 | |||
Minimum of Months | 7754569.68 | 1551.66 | -21.9 | |
Maximum of Months | 0.126536E+10 | 33227.62 | 19.50 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.124451E+10 | 26965.51 | 05-JAN-05:12 | -17.0 |
February | 0.198596E+10 | 27992.94 | 07-FEB-05:41 | -7.0 |
March | 0.171651E+10 | 27201.26 | 19-MAR-06:21 | -14.4 |
April | 0.144481E+10 | 26906.43 | 17-APR-04:11 | -8.0 |
May | 0.275654E+09 | 26623.36 | 03-MAY-04:01 | 1.83 |
June | 38323331.50 | 1101.41 | 11-JUN-07:23 | 16.10 |
July | 27276959.57 | 1103.29 | 04-JUL-07:23 | 16.50 |
August | 19868872.34 | 1296.05 | 17-AUG-05:03 | 12.00 |
September | 37235160.40 | 9159.34 | 22-SEP-04:20 | -0.6 |
October | 0.673957E+09 | 26778.71 | 31-OCT-04:12 | -8.0 |
November | 0.822176E+09 | 26953.78 | 30-NOV-05:12 | -12.7 |
December | 0.201279E+10 | 27999.40 | 20-DEC-05:31 | -19.0 |
Annual Sum or Average | 0.102991E+11 | |||
Minimum of Months | 19868872.34 | 1101.41 | -19.0 | |
Maximum of Months | 0.201279E+10 | 27999.40 | 16.50 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.118601E+11 | 41444.78 | 05-JAN-18:00 | -18.0 |
February | 0.118376E+11 | 34435.06 | 11-FEB-18:00 | -12.0 |
March | 0.936883E+10 | 31902.09 | 04-MAR-18:00 | -10.0 |
April | 0.835977E+10 | 25518.43 | 02-APR-13:00 | -4.0 |
May | 0.249464E+10 | 13538.94 | 02-MAY-11:05 | 8.17 |
June | 69685195.42 | 4388.12 | 02-JUN-15:00 | 16.10 |
July | 78612933.81 | 3741.45 | 30-JUL-16:55 | 17.00 |
August | 72081686.05 | 4131.74 | 29-AUG-16:00 | 16.00 |
September | 0.634597E+09 | 20330.68 | 21-SEP-17:00 | 0.50 |
October | 0.690535E+10 | 30299.00 | 31-OCT-17:00 | -8.0 |
November | 0.982630E+10 | 35636.63 | 29-NOV-18:00 | -13.0 |
December | 0.139569E+11 | 47158.02 | 21-DEC-18:00 | -22.0 |
Annual Sum or Average | 0.754645E+11 | |||
Minimum of Months | 69685195.42 | 3741.45 | -22.0 | |
Maximum of Months | 0.139569E+11 | 47158.02 | 17.00 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.281822E+10 | 2344.76 | 02-JAN-09:09 | 0.420015E+10 | 2754.45 | 02-JAN-09:09 |
February | 0.256399E+10 | 2344.76 | 01-FEB-09:09 | 0.381055E+10 | 2754.45 | 01-FEB-09:09 |
March | 0.292411E+10 | 2344.76 | 01-MAR-09:09 | 0.430594E+10 | 2754.45 | 01-MAR-09:09 |
April | 0.275920E+10 | 2344.76 | 01-APR-09:09 | 0.409182E+10 | 2754.45 | 01-APR-09:09 |
May | 0.287117E+10 | 2344.76 | 01-MAY-08:09 | 0.425304E+10 | 2754.45 | 01-MAY-08:09 |
June | 0.282172E+10 | 2344.76 | 01-JUN-08:09 | 0.415844E+10 | 2754.45 | 01-JUN-08:09 |
July | 0.280865E+10 | 2344.76 | 01-JUL-09:09 | 0.418643E+10 | 2754.45 | 01-JUL-09:09 |
August | 0.292411E+10 | 2344.76 | 01-AUG-08:09 | 0.430594E+10 | 2754.45 | 01-AUG-08:09 |
September | 0.275920E+10 | 2344.76 | 01-SEP-08:09 | 0.409182E+10 | 2754.45 | 01-SEP-08:09 |
October | 0.281822E+10 | 2344.76 | 02-OCT-08:09 | 0.420015E+10 | 2754.45 | 02-OCT-08:09 |
November | 0.272540E+10 | 2344.76 | 01-NOV-08:09 | 0.406638E+10 | 2754.45 | 01-NOV-08:09 |
December | 0.280865E+10 | 2344.76 | 01-DEC-09:09 | 0.418643E+10 | 2754.45 | 01-DEC-09:09 |
Annual Sum or Average | 0.336027E+11 | 0.498571E+11 | ||||
Minimum of Months | 0.256399E+10 | 2344.76 | 0.381055E+10 | 2754.45 | ||
Maximum of Months | 0.292411E+10 | 2344.76 | 0.430594E+10 | 2754.45 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.291685E+11 | 26047.91 | 02-JAN-09:09 | 0.708251E+10 | 4644.69 | 02-JAN-09:09 |
February | 0.268116E+11 | 26047.91 | 01-FEB-09:09 | 0.642555E+10 | 4644.69 | 01-FEB-09:09 |
March | 0.284894E+11 | 26047.91 | 01-MAR-09:09 | 0.726089E+10 | 4644.69 | 01-MAR-09:09 |
April | 0.237817E+11 | 26047.91 | 01-APR-09:09 | 0.689984E+10 | 4644.69 | 01-APR-09:09 |
May | 0.236565E+11 | 26047.91 | 03-MAY-16:19 | 0.717170E+10 | 4644.69 | 01-MAY-08:09 |
June | 0.245244E+11 | 26047.91 | 01-JUN-16:49 | 0.701217E+10 | 4644.69 | 01-JUN-08:09 |
July | 0.233607E+11 | 26047.91 | 01-JUL-16:19 | 0.705936E+10 | 4644.69 | 01-JUL-09:09 |
August | 0.254581E+11 | 26047.91 | 05-AUG-16:49 | 0.726089E+10 | 4644.69 | 01-AUG-08:09 |
September | 0.254714E+11 | 26047.91 | 01-SEP-16:49 | 0.689984E+10 | 4644.69 | 01-SEP-08:09 |
October | 0.283147E+11 | 26047.91 | 02-OCT-08:09 | 0.708251E+10 | 4644.69 | 02-OCT-08:09 |
November | 0.281792E+11 | 26047.91 | 01-NOV-08:09 | 0.685694E+10 | 4644.69 | 01-NOV-08:09 |
December | 0.300874E+11 | 26047.91 | 01-DEC-09:09 | 0.705936E+10 | 4644.69 | 01-DEC-09:09 |
Annual Sum or Average | 0.317304E+12 | 0.840716E+11 | ||||
Minimum of Months | 0.233607E+11 | 26047.91 | 0.642555E+10 | 4644.69 | ||
Maximum of Months | 0.300874E+11 | 26047.91 | 0.726089E+10 | 4644.69 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.293011E+10 | 2454.44 | 02-JAN-09:09 | 0.444637E+10 | 2915.92 | 02-JAN-09:09 |
February | 0.266601E+10 | 2454.44 | 01-FEB-09:09 | 0.403394E+10 | 2915.92 | 01-FEB-09:09 |
March | 0.304105E+10 | 2454.44 | 01-MAR-09:09 | 0.455836E+10 | 2915.92 | 01-MAR-09:09 |
April | 0.286924E+10 | 2454.44 | 01-APR-09:09 | 0.433169E+10 | 2915.92 | 01-APR-09:09 |
May | 0.298558E+10 | 2454.44 | 01-MAY-08:09 | 0.450237E+10 | 2915.92 | 01-MAY-08:09 |
June | 0.293453E+10 | 2454.44 | 01-JUN-08:09 | 0.440222E+10 | 2915.92 | 01-JUN-08:09 |
July | 0.292029E+10 | 2454.44 | 01-JUL-09:09 | 0.443184E+10 | 2915.92 | 01-JUL-09:09 |
August | 0.304105E+10 | 2454.44 | 01-AUG-08:09 | 0.455836E+10 | 2915.92 | 01-AUG-08:09 |
September | 0.286924E+10 | 2454.44 | 01-SEP-08:09 | 0.433169E+10 | 2915.92 | 01-SEP-08:09 |
October | 0.293011E+10 | 2454.44 | 02-OCT-08:09 | 0.444637E+10 | 2915.92 | 02-OCT-08:09 |
November | 0.283340E+10 | 2454.44 | 01-NOV-08:09 | 0.430476E+10 | 2915.92 | 01-NOV-08:09 |
December | 0.292029E+10 | 2454.44 | 01-DEC-09:09 | 0.443184E+10 | 2915.92 | 01-DEC-09:09 |
Annual Sum or Average | 0.349409E+11 | 0.527798E+11 | ||||
Minimum of Months | 0.266601E+10 | 2454.44 | 0.403394E+10 | 2915.92 | ||
Maximum of Months | 0.304105E+10 | 2454.44 | 0.455836E+10 | 2915.92 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.293011E+10 | 2454.44 | 02-JAN-09:09 | 0.667369E+09 | 437.66 | 02-JAN-09:09 |
February | 0.266601E+10 | 2454.44 | 01-FEB-09:09 | 0.605465E+09 | 437.66 | 01-FEB-09:09 |
March | 0.304105E+10 | 2454.44 | 01-MAR-09:09 | 0.684178E+09 | 437.66 | 01-MAR-09:09 |
April | 0.286924E+10 | 2454.44 | 01-APR-09:09 | 0.650156E+09 | 437.66 | 01-APR-09:09 |
May | 0.298558E+10 | 2454.44 | 01-MAY-08:09 | 0.675774E+09 | 437.66 | 01-MAY-08:09 |
June | 0.293453E+10 | 2454.44 | 01-JUN-08:09 | 0.660742E+09 | 437.66 | 01-JUN-08:09 |
July | 0.292029E+10 | 2454.44 | 01-JUL-09:09 | 0.665188E+09 | 437.66 | 01-JUL-09:09 |
August | 0.304105E+10 | 2454.44 | 01-AUG-08:09 | 0.684178E+09 | 437.66 | 01-AUG-08:09 |
September | 0.286924E+10 | 2454.44 | 01-SEP-08:09 | 0.650156E+09 | 437.66 | 01-SEP-08:09 |
October | 0.293011E+10 | 2454.44 | 02-OCT-08:09 | 0.667369E+09 | 437.66 | 02-OCT-08:09 |
November | 0.283340E+10 | 2454.44 | 01-NOV-08:09 | 0.646114E+09 | 437.66 | 01-NOV-08:09 |
December | 0.292029E+10 | 2454.44 | 01-DEC-09:09 | 0.665188E+09 | 437.66 | 01-DEC-09:09 |
Annual Sum or Average | 0.349409E+11 | 0.792188E+10 | ||||
Minimum of Months | 0.266601E+10 | 2454.44 | 0.605465E+09 | 437.66 | ||
Maximum of Months | 0.304105E+10 | 2454.44 | 0.684178E+09 | 437.66 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.103900E+09 | 85.79 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 94517577.03 | 85.79 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.107770E+09 | 85.79 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.101704E+09 | 85.79 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.105835E+09 | 85.79 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.103997E+09 | 85.79 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.103541E+09 | 85.79 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.107770E+09 | 85.79 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.101704E+09 | 85.79 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.103900E+09 | 85.79 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.100485E+09 | 85.79 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.103541E+09 | 85.79 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.123866E+10 | ||||
Minimum of Months | 94517577.03 | 85.79 | 0.00 | 0.00 | |
Maximum of Months | 0.107770E+09 | 85.79 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.281822E+10 | 0.420015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111321E+10 |
February | 0.479114E+10 | 0.256399E+10 | 0.381055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.173006E+10 |
March | 0.548013E+10 | 0.292411E+10 | 0.430594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 767.53 | 0.185937E+10 |
April | 0.518069E+10 | 0.275920E+10 | 0.409182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.190065E+10 |
May | 0.536353E+10 | 0.287117E+10 | 0.425304E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5321868.47 | 0.106043E+10 |
June | 0.528933E+10 | 0.282172E+10 | 0.415844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100767E+09 | 0.450465E+09 |
July | 0.525489E+10 | 0.280865E+10 | 0.418643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109720E+09 | 0.425116E+09 |
August | 0.548013E+10 | 0.292411E+10 | 0.430594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72048277.04 | 0.429665E+09 |
September | 0.518069E+10 | 0.275920E+10 | 0.409182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34368214.13 | 0.713229E+09 |
October | 0.524694E+10 | 0.281822E+10 | 0.420015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 765369.04 | 0.145397E+10 |
November | 0.504819E+10 | 0.272540E+10 | 0.406638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131896E+10 |
December | 0.525489E+10 | 0.280865E+10 | 0.418643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.248267E+10 |
Annual Sum or Average | 0.628175E+11 | 0.336027E+11 | 0.498571E+11 | 0.322992E+09 | 0.149378E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.256399E+10 | 0.381055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.425116E+09 |
Maximum of Months | 0.548013E+10 | 0.292411E+10 | 0.430594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109720E+09 | 0.248267E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.291685E+11 | 0.708251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.974208E+09 |
February | 0.201852E+11 | 0.268116E+11 | 0.642555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151658E+10 |
March | 0.230879E+11 | 0.284894E+11 | 0.726089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 630.60 | 0.165697E+10 |
April | 0.218263E+11 | 0.237817E+11 | 0.689984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170364E+10 |
May | 0.225967E+11 | 0.236565E+11 | 0.717170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4356931.60 | 0.964252E+09 |
June | 0.222841E+11 | 0.245244E+11 | 0.701217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82491399.38 | 0.370990E+09 |
July | 0.221389E+11 | 0.233607E+11 | 0.705936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89649630.13 | 0.348733E+09 |
August | 0.230879E+11 | 0.254581E+11 | 0.726089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58996010.64 | 0.349635E+09 |
September | 0.218263E+11 | 0.254714E+11 | 0.689984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28132235.40 | 0.597927E+09 |
October | 0.221054E+11 | 0.283147E+11 | 0.708251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 626640.61 | 0.127474E+10 |
November | 0.212681E+11 | 0.281792E+11 | 0.685694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114774E+10 |
December | 0.221389E+11 | 0.300874E+11 | 0.705936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215200E+10 |
Annual Sum or Average | 0.264651E+12 | 0.317304E+12 | 0.840716E+11 | 0.264253E+09 | 0.130574E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.233607E+11 | 0.642555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.348733E+09 |
Maximum of Months | 0.230879E+11 | 0.300874E+11 | 0.726089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89649630.13 | 0.215200E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.293011E+10 | 0.444637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537039E+09 |
February | 0.190200E+10 | 0.266601E+10 | 0.403394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.817780E+09 |
March | 0.217552E+10 | 0.304105E+10 | 0.455836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 333.40 | 0.869541E+09 |
April | 0.205665E+10 | 0.286924E+10 | 0.433169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.875824E+09 |
May | 0.212923E+10 | 0.298558E+10 | 0.450237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2306184.70 | 0.489315E+09 |
June | 0.209978E+10 | 0.293453E+10 | 0.440222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43779286.51 | 0.195863E+09 |
July | 0.208610E+10 | 0.292029E+10 | 0.443184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47672920.58 | 0.182207E+09 |
August | 0.217552E+10 | 0.304105E+10 | 0.455836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31295939.72 | 0.183012E+09 |
September | 0.205665E+10 | 0.286924E+10 | 0.433169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14941589.10 | 0.312982E+09 |
October | 0.208295E+10 | 0.293011E+10 | 0.444637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 331701.82 | 0.678873E+09 |
November | 0.200405E+10 | 0.283340E+10 | 0.430476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.627489E+09 |
December | 0.208610E+10 | 0.292029E+10 | 0.443184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116246E+10 |
Annual Sum or Average | 0.249375E+11 | 0.349409E+11 | 0.527798E+11 | 0.140328E+09 | 0.693238E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.266601E+10 | 0.403394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182207E+09 |
Maximum of Months | 0.217552E+10 | 0.304105E+10 | 0.455836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47672920.58 | 0.116246E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.293011E+10 | 0.667369E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.517614E+09 |
February | 0.190200E+10 | 0.266601E+10 | 0.605465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.793561E+09 |
March | 0.217552E+10 | 0.304105E+10 | 0.684178E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 333.38 | 0.838122E+09 |
April | 0.205665E+10 | 0.286924E+10 | 0.650156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.837650E+09 |
May | 0.212923E+10 | 0.298558E+10 | 0.675774E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2306133.63 | 0.462390E+09 |
June | 0.209978E+10 | 0.293453E+10 | 0.660742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 43662758.10 | 0.192444E+09 |
July | 0.208610E+10 | 0.292029E+10 | 0.665188E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47549650.25 | 0.182012E+09 |
August | 0.217552E+10 | 0.304105E+10 | 0.684178E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 31276756.62 | 0.184324E+09 |
September | 0.205665E+10 | 0.286924E+10 | 0.650156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14911615.93 | 0.310960E+09 |
October | 0.208295E+10 | 0.293011E+10 | 0.667369E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 331716.16 | 0.659905E+09 |
November | 0.200405E+10 | 0.283340E+10 | 0.646114E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.605916E+09 |
December | 0.208610E+10 | 0.292029E+10 | 0.665188E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112938E+10 |
Annual Sum or Average | 0.249375E+11 | 0.349409E+11 | 0.792188E+10 | 0.140039E+09 | 0.671427E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.266601E+10 | 0.605465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182012E+09 |
Maximum of Months | 0.217552E+10 | 0.304105E+10 | 0.684178E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47549650.25 | 0.112938E+10 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.103900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122307E+11 |
February | 0.00 | 94517577.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119909E+11 |
March | 0.00 | 0.107770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.948337E+10 |
April | 0.00 | 0.101704E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.828456E+10 |
May | 0.00 | 0.105835E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7906970.10 | 0.279049E+10 |
June | 0.00 | 0.103997E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243696E+09 | 0.267822E+09 |
July | 0.00 | 0.103541E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.233420E+09 | 0.281386E+09 |
August | 0.00 | 0.107770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143674E+09 | 0.371507E+09 |
September | 0.00 | 0.101704E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15621843.57 | 0.113471E+10 |
October | 0.00 | 0.103900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.758947E+10 |
November | 0.00 | 0.100485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104105E+11 |
December | 0.00 | 0.103541E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141634E+11 |
Annual Sum or Average | 0.00 | 0.123866E+10 | 0.644319E+09 | 0.789987E+11 | |||||
Minimum of Months | 0.00 | 94517577.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.267822E+09 |
Maximum of Months | 0.00 | 0.107770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243696E+09 | 0.141634E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 2344.76 | 02-JAN-09:09 | 2754.45 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2501.74 | 13-JAN-05:10 |
February | 5888.82 | 01-FEB-15:09 | 2344.76 | 01-FEB-09:09 | 2754.45 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2848.56 | 05-FEB-22:53 |
March | 5888.82 | 01-MAR-15:09 | 2344.76 | 01-MAR-09:09 | 2754.45 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.28 | 14-MAR-13:00 | 7400.87 | 19-MAR-06:51 |
April | 5888.82 | 01-APR-10:09 | 2344.76 | 01-APR-09:09 | 2754.45 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 4693.29 | 15-APR-05:00 |
May | 5888.82 | 01-MAY-14:09 | 2344.76 | 01-MAY-08:09 | 2754.45 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 125.55 | 17-MAY-14:50 | 2466.30 | 01-MAY-20:03 |
June | 5888.82 | 01-JUN-14:09 | 2344.76 | 01-JUN-08:09 | 2754.45 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 930.86 | 25-JUN-18:10 | 1413.41 | 08-JUN-22:53 |
July | 5888.82 | 01-JUL-10:09 | 2344.76 | 01-JUL-09:09 | 2754.45 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 725.99 | 02-JUL-18:03 | 1321.35 | 03-JUL-03:00 |
August | 5888.82 | 01-AUG-14:09 | 2344.76 | 01-AUG-08:09 | 2754.45 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 387.14 | 02-AUG-16:00 | 1277.21 | 27-AUG-18:10 |
September | 5888.82 | 01-SEP-14:09 | 2344.76 | 01-SEP-08:09 | 2754.45 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 347.17 | 10-SEP-18:10 | 1671.32 | 22-SEP-02:00 |
October | 5888.82 | 02-OCT-14:09 | 2344.76 | 02-OCT-08:09 | 2754.45 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 58.25 | 11-OCT-14:00 | 3650.18 | 29-OCT-19:00 |
November | 5888.82 | 01-NOV-14:09 | 2344.76 | 01-NOV-08:09 | 2754.45 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 4094.01 | 01-NOV-04:07 |
December | 5888.82 | 01-DEC-15:09 | 2344.76 | 01-DEC-09:09 | 2754.45 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5250.77 | 21-DEC-22:53 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1277.21 | |||||
Maximum of Months | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 930.86 | 7400.87 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 26047.91 | 02-JAN-09:09 | 4644.69 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2069.73 | 13-JAN-05:00 |
February | 24809.68 | 01-FEB-15:09 | 26047.91 | 01-FEB-09:09 | 4644.69 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2600.70 | 05-FEB-22:53 |
March | 24809.68 | 01-MAR-15:09 | 26047.91 | 01-MAR-09:09 | 4644.69 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.05 | 14-MAR-13:00 | 5672.37 | 19-MAR-06:51 |
April | 24809.68 | 01-APR-10:09 | 26047.91 | 01-APR-09:09 | 4644.69 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 3703.41 | 15-APR-05:00 |
May | 24809.68 | 01-MAY-14:09 | 26047.91 | 03-MAY-16:19 | 4644.69 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 102.77 | 17-MAY-14:50 | 2085.03 | 03-MAY-03:00 |
June | 24809.68 | 01-JUN-14:09 | 26047.91 | 01-JUN-16:49 | 4644.69 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 762.11 | 25-JUN-18:10 | 1189.20 | 08-JUN-22:30 |
July | 24809.68 | 01-JUL-10:09 | 26047.91 | 01-JUL-16:19 | 4644.69 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 592.22 | 02-JUL-18:03 | 1159.69 | 03-JUL-03:00 |
August | 24809.68 | 01-AUG-14:09 | 26047.91 | 05-AUG-16:49 | 4644.69 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 316.89 | 02-AUG-16:00 | 1102.94 | 27-AUG-18:10 |
September | 24809.68 | 01-SEP-14:09 | 26047.91 | 01-SEP-16:49 | 4644.69 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 284.25 | 10-SEP-18:10 | 1459.30 | 22-SEP-02:00 |
October | 24809.68 | 02-OCT-14:09 | 26047.91 | 02-OCT-08:09 | 4644.69 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.69 | 11-OCT-14:00 | 3243.80 | 29-OCT-19:00 |
November | 24809.68 | 01-NOV-14:09 | 26047.91 | 01-NOV-08:09 | 4644.69 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 3080.65 | 01-NOV-03:53 |
December | 24809.68 | 01-DEC-15:09 | 26047.91 | 01-DEC-09:09 | 4644.69 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 4652.94 | 21-DEC-22:53 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 26047.91 | 4644.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1102.94 | |||||
Maximum of Months | 24809.68 | 26047.91 | 4644.69 | 0.00 | 0.00 | 0.00 | 0.00 | 762.11 | 5672.37 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2454.44 | 02-JAN-09:09 | 2915.92 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1097.31 | 13-JAN-05:03 |
February | 2337.76 | 01-FEB-15:09 | 2454.44 | 01-FEB-09:09 | 2915.92 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1379.07 | 23-FEB-24:00 |
March | 2337.76 | 01-MAR-15:09 | 2454.44 | 01-MAR-09:09 | 2915.92 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.56 | 14-MAR-13:00 | 3243.49 | 19-MAR-07:00 |
April | 2337.76 | 01-APR-10:09 | 2454.44 | 01-APR-09:09 | 2915.92 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 2033.74 | 15-APR-05:00 |
May | 2337.76 | 01-MAY-14:09 | 2454.44 | 01-MAY-08:09 | 2915.92 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 54.40 | 17-MAY-14:50 | 1157.32 | 01-MAY-20:03 |
June | 2337.76 | 01-JUN-14:09 | 2454.44 | 01-JUN-08:09 | 2915.92 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 399.46 | 25-JUN-18:10 | 640.55 | 08-JUN-22:53 |
July | 2337.76 | 01-JUL-10:09 | 2454.44 | 01-JUL-09:09 | 2915.92 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 322.93 | 02-JUL-18:10 | 585.32 | 03-JUL-03:00 |
August | 2337.76 | 01-AUG-14:09 | 2454.44 | 01-AUG-08:09 | 2915.92 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 167.76 | 02-AUG-16:00 | 601.15 | 27-AUG-18:10 |
September | 2337.76 | 01-SEP-14:09 | 2454.44 | 01-SEP-08:09 | 2915.92 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 153.55 | 10-SEP-18:10 | 736.76 | 21-SEP-23:00 |
October | 2337.76 | 02-OCT-14:09 | 2454.44 | 02-OCT-08:09 | 2915.92 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.25 | 11-OCT-14:00 | 1627.47 | 29-OCT-19:00 |
November | 2337.76 | 01-NOV-14:09 | 2454.44 | 01-NOV-08:09 | 2915.92 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 1773.91 | 01-NOV-04:05 |
December | 2337.76 | 01-DEC-15:09 | 2454.44 | 01-DEC-09:09 | 2915.92 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2320.41 | 21-DEC-22:53 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 585.32 | |||||
Maximum of Months | 2337.76 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 399.46 | 3243.49 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2454.44 | 02-JAN-09:09 | 437.66 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1086.75 | 13-JAN-05:04 |
February | 2337.76 | 01-FEB-15:09 | 2454.44 | 01-FEB-09:09 | 437.66 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1315.07 | 23-FEB-24:00 |
March | 2337.76 | 01-MAR-15:09 | 2454.44 | 01-MAR-09:09 | 437.66 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.56 | 14-MAR-13:00 | 3244.44 | 19-MAR-06:54 |
April | 2337.76 | 01-APR-10:09 | 2454.44 | 01-APR-09:09 | 437.66 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 2033.74 | 15-APR-05:00 |
May | 2337.76 | 01-MAY-14:09 | 2454.44 | 01-MAY-08:09 | 437.66 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 54.40 | 17-MAY-14:50 | 1068.63 | 01-MAY-20:03 |
June | 2337.76 | 01-JUN-14:09 | 2454.44 | 01-JUN-08:09 | 437.66 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 401.31 | 25-JUN-18:10 | 606.93 | 08-JUN-22:53 |
July | 2337.76 | 01-JUL-10:09 | 2454.44 | 01-JUL-09:09 | 437.66 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 325.63 | 02-JUL-18:10 | 562.68 | 03-JUL-03:00 |
August | 2337.76 | 01-AUG-14:09 | 2454.44 | 01-AUG-08:09 | 437.66 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 167.76 | 02-AUG-16:00 | 578.53 | 27-AUG-18:10 |
September | 2337.76 | 01-SEP-14:09 | 2454.44 | 01-SEP-08:09 | 437.66 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 153.77 | 10-SEP-18:10 | 711.77 | 22-SEP-02:00 |
October | 2337.76 | 02-OCT-14:09 | 2454.44 | 02-OCT-08:09 | 437.66 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.25 | 11-OCT-14:00 | 1591.31 | 29-OCT-19:00 |
November | 2337.76 | 01-NOV-14:09 | 2454.44 | 01-NOV-08:09 | 437.66 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 1706.88 | 01-NOV-04:20 |
December | 2337.76 | 01-DEC-15:09 | 2454.44 | 01-DEC-09:09 | 437.66 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2281.37 | 21-DEC-22:53 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 562.68 | |||||
Maximum of Months | 2337.76 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 401.31 | 3244.44 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 85.79 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 40932.02 | 05-JAN-18:00 |
February | 0.00 | 01-FEB-00:10 | 85.79 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 34408.91 | 11-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 85.79 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 31510.48 | 04-MAR-18:00 |
April | 0.00 | 01-APR-00:10 | 85.79 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 25108.83 | 02-APR-13:00 |
May | 0.00 | 01-MAY-00:10 | 85.79 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 320.72 | 31-MAY-11:05 | 14125.31 | 02-MAY-11:02 |
June | 0.00 | 01-JUN-00:10 | 85.79 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2837.98 | 26-JUN-11:01 | 5202.64 | 02-JUN-15:00 |
July | 0.00 | 01-JUL-00:10 | 85.79 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3288.74 | 16-JUL-11:01 | 4534.95 | 30-JUL-16:55 |
August | 0.00 | 01-AUG-00:10 | 85.79 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2731.06 | 16-AUG-11:01 | 5147.34 | 29-AUG-16:00 |
September | 0.00 | 01-SEP-00:10 | 85.79 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 777.48 | 09-SEP-11:02 | 20623.62 | 21-SEP-16:00 |
October | 0.00 | 01-OCT-00:10 | 85.79 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 29844.66 | 30-OCT-11:10 |
November | 0.00 | 01-NOV-00:10 | 85.79 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 35330.18 | 29-NOV-18:00 |
December | 0.00 | 01-DEC-00:10 | 85.79 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 46568.94 | 21-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 85.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4534.95 | ||||
Maximum of Months | 0.00 | 85.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3288.74 | 46568.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2793.54 | 26-JAN-18:05 | 7361.02 | 2605.29 | 5508.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.18 |
February | 3109.05 | 28-FEB-15:20 | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 299.61 |
March | 4958.80 | 15-MAR-14:50 | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.98 |
April | 4273.45 | 21-APR-14:10 | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.37 |
May | 7741.16 | 18-MAY-14:50 | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.22 |
June | 36717.30 | 28-JUN-00:31 | 0.00 | 1293.59 | 5473.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 299.78 |
July | 35210.91 | 08-JUL-21:25 | 0.00 | 1437.32 | 4561.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 236.56 |
August | 37380.59 | 17-AUG-20:53 | 0.00 | 5749.28 | 6081.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.89 |
September | 37084.60 | 07-SEP-20:17 | 0.00 | 5749.28 | 6081.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.94 |
October | 7685.40 | 11-OCT-14:40 | 5888.82 | 2344.76 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 53.14 | 0.00 |
November | 4112.75 | 10-NOV-18:30 | 3680.51 | 1302.64 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 336.27 |
December | 3968.41 | 07-DEC-16:35 | 10305.43 | 4689.51 | 5508.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 416.69 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2793.54 | 0.00 | 1293.59 | 2754.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 37380.59 | 10305.43 | 5749.28 | 6081.76 | 0.00 | 0.00 | 0.00 | 0.00 | 53.14 | 416.69 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 52913.07 | 15-JAN-09:05 | 12404.84 | 11576.85 | 6192.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.26 |
February | 50081.54 | 02-FEB-07:05 | 12404.84 | 23153.70 | 8257.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 351.22 |
March | 101660.86 | 14-MAR-20:25 | 0.00 | 11576.85 | 2051.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.05 |
April | 46477.99 | 17-APR-06:05 | 12404.84 | 23153.70 | 8257.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 501.02 |
May | 127857.14 | 10-MAY-21:01 | 0.00 | 14471.06 | 10255.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.38 |
June | 162075.82 | 06-JUN-00:51 | 0.00 | 13023.96 | 9229.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 357.72 |
July | 167491.94 | 14-JUL-00:51 | 0.00 | 13023.96 | 9229.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 337.37 |
August | 167044.76 | 31-AUG-23:51 | 0.00 | 13023.96 | 9229.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 197.40 |
September | 157344.39 | 29-SEP-22:50 | 0.00 | 14471.06 | 10255.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 272.82 |
October | 52001.96 | 30-OCT-06:05 | 12404.84 | 23153.70 | 8257.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 298.01 |
November | 50085.66 | 29-NOV-07:05 | 12404.84 | 23153.70 | 8257.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182.02 |
December | 52885.57 | 19-DEC-07:05 | 12404.84 | 23153.70 | 8257.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 541.35 |
Annual Sum or Average | |||||||||||
Minimum of Months | 46477.99 | 0.00 | 11576.85 | 2051.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.26 | |
Maximum of Months | 167491.94 | 12404.84 | 23153.70 | 10255.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 541.35 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 9332.50 | 20-JAN-13:50 | 2045.54 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.01 |
February | 9066.21 | 18-FEB-14:00 | 2337.76 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.59 |
March | 9406.38 | 15-MAR-13:30 | 2045.54 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.07 |
April | 6441.95 | 21-APR-13:30 | 2045.54 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.04 |
May | 24021.91 | 17-MAY-21:20 | 0.00 | 954.50 | 4506.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.27 |
June | 23547.00 | 12-JUN-23:31 | 0.00 | 1090.86 | 5150.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.31 |
July | 23537.17 | 07-JUL-02:61 | 0.00 | 1090.86 | 5150.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.38 |
August | 24490.65 | 17-AUG-01:43 | 0.00 | 409.07 | 1931.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.08 |
September | 24624.90 | 26-SEP-20:10 | 0.00 | 1636.29 | 1931.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.26 |
October | 30869.93 | 15-OCT-18:09 | 0.00 | 1090.86 | 3862.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.95 |
November | 28091.28 | 05-NOV-19:02 | 0.00 | 818.15 | 2897.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.91 |
December | 8963.41 | 02-DEC-13:40 | 2337.76 | 2454.44 | 2915.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.55 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6441.95 | 0.00 | 409.07 | 1931.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.01 | |
Maximum of Months | 30869.93 | 2337.76 | 2454.44 | 5150.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.91 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6902.20 | 20-JAN-14:00 | 2045.54 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.88 |
February | 6696.16 | 18-FEB-14:10 | 2337.76 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.76 |
March | 7217.67 | 15-MAR-13:30 | 2045.54 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.07 |
April | 4171.00 | 21-APR-13:30 | 2045.54 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.04 |
May | 4816.24 | 18-MAY-14:40 | 2337.76 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.84 |
June | 18086.01 | 28-JUN-00:06 | 0.00 | 1227.22 | 869.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.19 |
July | 18285.59 | 13-JUL-22:39 | 0.00 | 1090.86 | 773.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.46 |
August | 18911.52 | 16-AUG-23:46 | 0.00 | 1227.22 | 869.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 227.21 |
September | 20661.36 | 14-SEP-21:02 | 0.00 | 681.79 | 483.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 291.15 |
October | 20604.87 | 08-OCT-18:10 | 0.00 | 409.07 | 217.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 206.74 |
November | 8617.18 | 07-NOV-13:50 | 2045.54 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.87 |
December | 6628.45 | 02-DEC-14:30 | 2337.76 | 2454.44 | 437.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.32 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4171.00 | 0.00 | 409.07 | 217.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.84 | |
Maximum of Months | 20661.36 | 2337.76 | 2454.44 | 869.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 291.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.41 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.65 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.12 |
April | 0.00 | 01-APR-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.65 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.38 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.95 |
July | 0.00 | 01-JUL-00:01 | 0.00 | 58.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.89 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.30 |
September | 0.00 | 01-SEP-00:05 | 0.00 | 11.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.51 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.54 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 11.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.68 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.87 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.89 | |
Maximum of Months | 0.00 | 0.00 | 58.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.68 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.822784E+11 | 64383.93 | 05-JAN-17:00 | 0.719065E+11 | 195532.99 | 05-JAN-07:10 |
February | 0.748368E+11 | 63552.80 | 06-FEB-17:00 | 0.735476E+11 | 186042.03 | 06-FEB-07:10 |
March | 0.815447E+11 | 68140.70 | 13-MAR-15:30 | 0.516584E+11 | 186621.17 | 19-MAR-08:09 |
April | 0.731428E+11 | 60594.74 | 07-APR-16:40 | 0.397358E+11 | 161620.29 | 17-APR-06:10 |
May | 0.776455E+11 | 74133.31 | 31-MAY-15:50 | 0.108578E+11 | 67309.55 | 02-MAY-06:19 |
June | 0.983886E+11 | 98835.91 | 26-JUN-15:30 | 0.776506E+10 | 6202.72 | 02-JUN-15:00 |
July | 0.989788E+11 | 87309.00 | 15-JUL-14:50 | 0.782474E+10 | 4975.78 | 03-JUL-11:09 |
August | 0.100934E+12 | 93839.08 | 16-AUG-15:00 | 0.786309E+10 | 5157.70 | 29-AUG-16:19 |
September | 0.903913E+11 | 81591.84 | 28-SEP-14:50 | 0.816274E+10 | 32368.23 | 22-SEP-06:49 |
October | 0.811005E+11 | 76190.82 | 11-OCT-14:00 | 0.306189E+11 | 152269.22 | 31-OCT-06:10 |
November | 0.787992E+11 | 65091.83 | 07-NOV-14:30 | 0.478073E+11 | 174114.43 | 30-NOV-07:10 |
December | 0.838909E+11 | 64945.24 | 21-DEC-17:00 | 0.912510E+11 | 236398.04 | 23-DEC-07:10 |
Annual Sum or Average | 0.102193E+13 | 0.448999E+12 | ||||
Minimum of Months | 0.731428E+11 | 60594.74 | 0.776506E+10 | 4975.78 | ||
Maximum of Months | 0.100934E+12 | 98835.91 | 0.912510E+11 | 236398.04 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.379509E+11 | 0.641191E+10 | 0.163964E+11 | 0.00 | 0.213802E+11 | 0.00 | 0.00 | 0.139004E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.348021E+11 | 0.533225E+10 | 0.148755E+11 | 0.00 | 0.197611E+11 | 0.00 | 0.00 | 65766457.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.376034E+11 | 0.525548E+10 | 0.168094E+11 | 0.00 | 0.208491E+11 | 0.00 | 0.00 | 0.102739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.323811E+11 | 0.442930E+10 | 0.159735E+11 | 0.00 | 0.198373E+11 | 0.00 | 0.00 | 0.521495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.326047E+11 | 0.405166E+10 | 0.166029E+11 | 0.00 | 0.181731E+11 | 0.00 | 0.00 | 0.621322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.333192E+11 | 0.366380E+10 | 0.162336E+11 | 0.00 | 0.167224E+11 | 0.00 | 0.00 | 0.284496E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.321135E+11 | 0.387901E+10 | 0.163428E+11 | 0.00 | 0.170253E+11 | 0.00 | 0.00 | 0.296182E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.345720E+11 | 0.432476E+10 | 0.168094E+11 | 0.00 | 0.174966E+11 | 0.00 | 0.00 | 0.277315E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.340708E+11 | 0.479992E+10 | 0.159735E+11 | 0.00 | 0.167799E+11 | 0.00 | 0.00 | 0.187672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.370970E+11 | 0.563724E+10 | 0.163964E+11 | 0.00 | 0.193445E+11 | 0.00 | 0.00 | 0.262532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.366719E+11 | 0.603437E+10 | 0.158742E+11 | 0.00 | 0.196754E+11 | 0.00 | 0.00 | 0.543411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.388401E+11 | 0.657353E+10 | 0.163428E+11 | 0.00 | 0.219422E+11 | 0.00 | 0.00 | 0.192197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.422027E+12 | 0.603932E+11 | 0.194630E+12 | 0.228987E+12 | 0.00 | 0.115894E+12 | |||||||
Minimum of Months | 0.321135E+11 | 0.366380E+10 | 0.148755E+11 | 0.00 | 0.167224E+11 | 0.00 | 0.00 | 65766457.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.388401E+11 | 0.657353E+10 | 0.168094E+11 | 0.00 | 0.219422E+11 | 0.00 | 0.00 | 0.296182E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.634870E+11 | 0.00 | 0.841950E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.658852E+11 | 0.00 | 0.766242E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.431566E+11 | 0.00 | 0.850182E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.316752E+11 | 0.00 | 0.806063E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.270534E+10 | 0.00 | 0.815245E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 9317324.73 | 0.00 | 0.775574E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 69180.19 | 0.00 | 0.782467E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 2039083.17 | 0.00 | 0.786105E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.547280E+09 | 0.00 | 0.761546E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.226462E+11 | 0.00 | 0.797268E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.399372E+11 | 0.00 | 0.787015E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.829388E+11 | 0.00 | 0.831225E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.352990E+12 | 0.960088E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 69180.19 | 0.00 | 0.761546E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.829388E+11 | 0.00 | 0.850182E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 33387.34 | 02-JAN-09:09 | 4644.30 | 01-JAN-06:10 | 10752.72 | 02-JAN-09:09 | 0.00 | 16984.73 | 05-JAN-07:30 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 33387.34 | 01-FEB-09:09 | 4644.30 | 01-FEB-06:10 | 10752.72 | 01-FEB-09:09 | 0.00 | 17148.10 | 12-FEB-09:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 33387.34 | 01-MAR-09:09 | 4644.30 | 01-MAR-06:10 | 10752.72 | 01-MAR-09:09 | 0.00 | 17114.95 | 19-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 33387.34 | 01-APR-09:09 | 4644.30 | 01-APR-05:10 | 10752.72 | 01-APR-09:09 | 0.00 | 15948.73 | 17-APR-06:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 33387.34 | 03-MAY-16:19 | 4644.30 | 01-MAY-18:49 | 10752.72 | 01-MAY-08:09 | 0.00 | 13978.05 | 02-MAY-07:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 33387.34 | 01-JUN-16:49 | 4644.30 | 01-JUN-19:19 | 10752.72 | 01-JUN-08:09 | 0.00 | 13461.40 | 26-JUN-14:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 33387.34 | 01-JUL-16:19 | 4644.30 | 01-JUL-19:30 | 10752.72 | 01-JUL-09:09 | 0.00 | 12778.67 | 03-JUL-11:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 33387.34 | 05-AUG-16:49 | 4644.30 | 01-AUG-19:10 | 10752.72 | 01-AUG-08:09 | 0.00 | 12778.67 | 13-AUG-11:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 33387.34 | 01-SEP-16:49 | 4644.30 | 01-SEP-05:10 | 10752.72 | 01-SEP-08:09 | 0.00 | 13302.83 | 22-SEP-07:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 33387.34 | 02-OCT-08:09 | 4644.30 | 01-OCT-05:10 | 10752.72 | 02-OCT-08:09 | 0.00 | 15936.90 | 30-OCT-06:30 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 33387.34 | 01-NOV-08:09 | 4644.30 | 01-NOV-05:10 | 10752.72 | 01-NOV-08:09 | 0.00 | 15827.90 | 29-NOV-07:49 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 33387.34 | 01-DEC-09:09 | 4644.30 | 01-DEC-06:10 | 10752.72 | 01-DEC-09:09 | 0.00 | 17924.28 | 23-DEC-07:19 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 33387.34 | 4644.30 | 10752.72 | 0.00 | 12778.67 | 0.00 | 0.00 | |||||
Maximum of Months | 33387.34 | 4644.30 | 10752.72 | 0.00 | 17924.28 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 6101.63 | 20-JAN-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5261.56 | 18-FEB-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 16713.79 | 14-MAR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 9650.06 | 20-APR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 22541.54 | 31-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 45116.02 | 26-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 36134.23 | 15-JUL-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 40229.12 | 16-AUG-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31476.11 | 09-SEP-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 23314.99 | 11-OCT-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 11058.85 | 07-NOV-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 7547.69 | 02-DEC-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 5261.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 45116.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 64383.93 | 05-JAN-17:00 | 33387.34 | 10752.72 | 4644.30 | 0.00 | 15599.58 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 63552.80 | 06-FEB-17:00 | 33387.34 | 10752.72 | 4644.30 | 0.00 | 14768.45 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 68140.70 | 13-MAR-15:30 | 33387.34 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 14107.72 | 0.00 |
April | 60594.74 | 07-APR-16:40 | 33387.34 | 10752.72 | 0.00 | 0.00 | 12778.67 | 0.00 | 0.00 | 3676.02 | 0.00 |
May | 74133.31 | 31-MAY-15:50 | 31216.68 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 22270.99 | 0.00 |
June | 98835.91 | 26-JUN-15:30 | 31216.68 | 10752.72 | 0.00 | 0.00 | 13099.58 | 0.00 | 0.00 | 43766.94 | 0.00 |
July | 87309.00 | 15-JUL-14:50 | 29046.02 | 10752.72 | 0.00 | 0.00 | 11376.04 | 0.00 | 0.00 | 36134.23 | 0.00 |
August | 93839.08 | 16-AUG-15:00 | 31216.68 | 10752.72 | 0.00 | 0.00 | 12039.27 | 0.00 | 0.00 | 39830.43 | 0.00 |
September | 81591.84 | 28-SEP-14:50 | 33387.34 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 27558.86 | 0.00 |
October | 76190.82 | 11-OCT-14:00 | 33387.34 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 22157.84 | 0.00 |
November | 65091.83 | 07-NOV-14:30 | 33387.34 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 11058.85 | 0.00 |
December | 64945.24 | 21-DEC-17:00 | 33387.34 | 10752.72 | 4644.30 | 0.00 | 16160.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 60594.74 | 29046.02 | 10752.72 | 0.00 | 0.00 | 9892.93 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 98835.91 | 33387.34 | 10752.72 | 4644.30 | 0.00 | 16160.89 | 0.00 | 0.00 | 43766.94 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 193672.99 | 05-JAN-07:10 | 0.00 | 5137.51 | 31-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 184182.03 | 06-FEB-07:10 | 0.00 | 5139.91 | 16-FEB-12:20 | 0.00 |
March | 0.00 | 0.00 | 182063.12 | 19-MAR-08:09 | 0.00 | 5135.90 | 01-MAR-12:20 | 0.00 |
April | 0.00 | 0.00 | 157057.78 | 17-APR-06:10 | 0.00 | 5106.64 | 03-APR-11:09 | 0.00 |
May | 0.00 | 0.00 | 65006.77 | 02-MAY-06:10 | 0.00 | 5067.92 | 01-MAY-11:50 | 0.00 |
June | 0.00 | 0.00 | 4263.65 | 30-JUN-04:10 | 0.00 | 5016.81 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 79.78 | 19-JUL-16:00 | 0.00 | 4975.78 | 03-JUL-11:09 | 0.00 |
August | 0.00 | 0.00 | 1022.10 | 20-AUG-06:40 | 0.00 | 4957.21 | 31-AUG-11:00 | 0.00 |
September | 0.00 | 0.00 | 29095.55 | 22-SEP-06:49 | 0.00 | 4978.86 | 29-SEP-11:30 | 0.00 |
October | 0.00 | 0.00 | 150409.22 | 31-OCT-06:10 | 0.00 | 5024.54 | 31-OCT-11:50 | 0.00 |
November | 0.00 | 0.00 | 169555.53 | 30-NOV-07:10 | 0.00 | 5071.02 | 30-NOV-12:20 | 0.00 |
December | 0.00 | 0.00 | 234538.04 | 23-DEC-07:10 | 0.00 | 5110.27 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 79.78 | 0.00 | 4957.21 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 234538.04 | 0.00 | 5139.91 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 7.83 | 19.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8.33 | 19.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6.83 | 19.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 4.50 | 20.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.50 | 20.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
October | 1.83 | 20.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5.17 | 20.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 10.33 | 18.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 45.33 | 19.68 | 0.00 | 0.67 | 24.48 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 10.33 | 20.21 | 0.00 | 0.00 | 0.17 | 24.50 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.49 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 24.50 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 24.49 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.51 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 17.33 | 24.49 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 24.51 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.17 | 20.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4.00 | 19.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 3.83 | 20.05 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
April | 2.83 | 20.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.50 | 20.34 | 0.00 | 0.00 | 0.17 | 24.47 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 24.53 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 24.51 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.00 | 24.53 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 24.50 | 0.00 | 0.00 |
October | 0.83 | 20.00 | 0.00 | 0.00 | 2.50 | 24.48 | 0.00 | 0.00 |
November | 1.67 | 20.00 | 0.00 | 0.00 | 0.33 | 24.48 | 0.00 | 0.00 |
December | 4.67 | 19.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 21.50 | 19.73 | 0.00 | 29.00 | 24.52 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4.67 | 20.34 | 0.00 | 0.00 | 8.00 | 24.53 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 4.17 | 19.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6.00 | 19.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 5.00 | 19.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 4.33 | 19.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.50 | 20.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.51 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.52 | 0.00 | 0.00 |
October | 1.17 | 19.90 | 0.00 | 0.00 | 0.17 | 24.46 | 0.00 | 0.00 |
November | 2.83 | 19.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 7.17 | 18.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 31.17 | 19.37 | 0.00 | 5.67 | 24.50 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 7.17 | 20.02 | 0.00 | 0.00 | 2.00 | 24.52 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.32 | 274.33 | 21.11 | 274.33 | 21.11 |
February | 376.00 | 21.24 | 285.50 | 21.11 | 285.50 | 21.11 |
March | 422.00 | 21.76 | 237.67 | 21.12 | 237.67 | 21.12 |
April | 405.00 | 21.94 | 138.33 | 21.11 | 138.33 | 21.11 |
May | 384.50 | 23.26 | 22.00 | 21.60 | 22.00 | 21.60 |
June | 68.33 | 23.84 | 167.67 | 23.89 | 11.67 | 23.89 |
July | 97.17 | 23.87 | 208.83 | 23.88 | 55.50 | 23.87 |
August | 64.33 | 23.85 | 186.67 | 23.89 | 13.00 | 23.89 |
September | 163.50 | 23.62 | 46.50 | 23.89 | 0.00 | 0.00 |
October | 413.00 | 22.60 | 70.17 | 21.11 | 70.17 | 21.11 |
November | 399.00 | 21.68 | 160.33 | 21.11 | 160.33 | 21.11 |
December | 415.00 | 21.31 | 319.50 | 21.12 | 319.50 | 21.12 |
Annual Sum or Average | 3621.83 | 22.09 | 2117.50 | 21.92 | 1588.00 | 21.26 |
Minimum of Months | 64.33 | 21.24 | 22.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.87 | 319.50 | 23.89 | 319.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.53 | 128.83 | 21.11 | 128.83 | 21.11 |
February | 376.00 | 21.47 | 134.83 | 21.11 | 134.83 | 21.11 |
March | 408.33 | 22.00 | 60.83 | 21.11 | 60.83 | 21.11 |
April | 383.67 | 22.12 | 49.33 | 21.11 | 49.33 | 21.11 |
May | 171.83 | 23.07 | 36.33 | 23.75 | 1.83 | 21.11 |
June | 20.00 | 23.81 | 247.50 | 23.89 | 4.50 | 23.89 |
July | 52.83 | 23.86 | 287.50 | 23.89 | 39.83 | 23.89 |
August | 24.67 | 23.80 | 276.33 | 23.89 | 10.33 | 23.89 |
September | 84.17 | 23.41 | 97.17 | 23.89 | 0.00 | 0.00 |
October | 327.00 | 22.44 | 32.50 | 21.11 | 32.50 | 21.11 |
November | 391.33 | 21.84 | 49.83 | 21.11 | 49.83 | 21.11 |
December | 415.00 | 21.50 | 179.83 | 21.11 | 179.83 | 21.11 |
Annual Sum or Average | 3068.83 | 22.00 | 1580.83 | 22.77 | 692.50 | 21.33 |
Minimum of Months | 20.00 | 21.47 | 32.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 415.00 | 23.86 | 287.50 | 23.89 | 179.83 | 23.89 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 317.50 | 22.47 | 68.83 | 21.35 | 62.83 | 21.11 |
February | 304.00 | 22.26 | 99.17 | 21.15 | 97.67 | 21.11 |
March | 346.17 | 22.47 | 92.50 | 21.12 | 92.50 | 21.12 |
April | 351.00 | 22.55 | 81.33 | 21.15 | 80.33 | 21.12 |
May | 197.00 | 23.49 | 36.50 | 23.37 | 6.83 | 21.12 |
June | 33.50 | 23.88 | 261.17 | 23.89 | 8.67 | 23.89 |
July | 64.00 | 23.89 | 297.00 | 23.89 | 44.83 | 23.89 |
August | 23.67 | 23.89 | 311.83 | 23.89 | 9.33 | 23.89 |
September | 60.67 | 23.67 | 206.33 | 23.89 | 0.00 | 0.00 |
October | 203.17 | 22.55 | 101.67 | 22.80 | 39.83 | 21.11 |
November | 250.67 | 22.60 | 65.17 | 22.45 | 33.83 | 21.11 |
December | 343.00 | 22.25 | 111.67 | 21.12 | 111.67 | 21.12 |
Annual Sum or Average | 2494.33 | 22.62 | 1733.17 | 23.05 | 588.33 | 21.41 |
Minimum of Months | 23.67 | 22.25 | 36.50 | 21.12 | 0.00 | 0.00 |
Maximum of Months | 351.00 | 23.89 | 311.83 | 23.89 | 111.67 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 356.00 | 21.94 | 89.83 | 21.11 | 89.83 | 21.11 |
February | 330.83 | 21.81 | 127.33 | 21.11 | 127.33 | 21.11 |
March | 373.00 | 22.02 | 137.50 | 21.11 | 137.50 | 21.11 |
April | 391.33 | 22.11 | 107.00 | 21.11 | 107.00 | 21.11 |
May | 289.83 | 23.14 | 21.50 | 22.23 | 12.83 | 21.11 |
June | 54.83 | 23.81 | 219.33 | 23.89 | 12.50 | 23.89 |
July | 83.00 | 23.86 | 259.50 | 23.89 | 53.83 | 23.88 |
August | 38.83 | 23.82 | 279.83 | 23.89 | 13.00 | 23.89 |
September | 79.67 | 23.44 | 170.00 | 23.89 | 0.00 | 0.00 |
October | 243.50 | 22.26 | 93.17 | 22.29 | 53.50 | 21.11 |
November | 292.33 | 22.07 | 63.33 | 21.61 | 52.00 | 21.11 |
December | 367.00 | 21.82 | 155.83 | 21.11 | 155.83 | 21.11 |
Annual Sum or Average | 2900.17 | 22.26 | 1724.17 | 22.70 | 815.17 | 21.38 |
Minimum of Months | 38.83 | 21.81 | 21.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 391.33 | 23.86 | 279.83 | 23.89 | 155.83 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.32422 | 26.84362 | -0.5947 | 13.01826 |
February | 376.00000 | 21.24389 | 23.79755 | -0.6396 | 14.09200 |
March | 422.00000 | 21.76018 | 23.52377 | -0.4770 | 11.21635 |
April | 405.00000 | 21.93036 | 27.63973 | -0.3918 | 9.86049 |
May | 418.00000 | 23.29868 | 29.96478 | -0.9840 | 27.17493 |
June | 408.00000 | 23.88102 | 36.12962 | -0.5642 | 11.85846 |
July | 415.00000 | 23.88390 | 38.77310 | -0.5458 | 11.41159 |
August | 422.00000 | 23.88217 | 37.15260 | -0.5550 | 11.63590 |
September | 405.00000 | 23.77925 | 28.70690 | -0.6881 | 15.77390 |
October | 414.00000 | 22.59844 | 24.65687 | -0.1968 | 7.76729 |
November | 399.00000 | 21.67639 | 27.62570 | -0.4510 | 10.44162 |
December | 415.00000 | 21.31310 | 20.01496 | -0.6397 | 14.27103 |
Annual Sum or Average | 4913.00000 | 22.55915 | 28.77687 | -0.5606 | 13.22028 |
Minimum of Months | 376.00000 | 21.24389 | 20.01496 | -0.9840 | 7.76729 |
Maximum of Months | 422.00000 | 23.88390 | 38.77310 | -0.1968 | 27.17493 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.52561 | 23.03589 | -0.4310 | 9.95001 |
February | 376.00000 | 21.46376 | 20.53457 | -0.4566 | 10.45401 |
March | 422.00000 | 22.05430 | 20.34172 | -0.2774 | 8.44675 |
April | 405.00000 | 22.21142 | 24.61628 | -0.2048 | 7.76367 |
May | 418.00000 | 23.54851 | 27.87065 | -0.7322 | 17.75792 |
June | 408.00000 | 23.88336 | 33.79687 | -0.4566 | 9.57736 |
July | 415.00000 | 23.88449 | 36.65771 | -0.4530 | 9.49057 |
August | 422.00000 | 23.87969 | 34.98982 | -0.4622 | 9.66983 |
September | 405.00000 | 23.78721 | 26.87341 | -0.5863 | 12.86600 |
October | 414.00000 | 22.74454 | 22.17659 | -0.0545 | 7.04510 |
November | 399.00000 | 21.87413 | 24.32484 | -0.2968 | 8.31616 |
December | 415.00000 | 21.49431 | 16.97919 | -0.4900 | 11.12284 |
Annual Sum or Average | 4913.00000 | 22.70700 | 26.06273 | -0.4086 | 10.21168 |
Minimum of Months | 376.00000 | 21.46376 | 16.97919 | -0.7322 | 7.04510 |
Maximum of Months | 422.00000 | 23.88449 | 36.65771 | -0.0545 | 17.75792 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.79280 | 20.15918 | -0.0865 | 7.88138 |
February | 376.00000 | 22.56683 | 17.96982 | -0.1820 | 9.10578 |
March | 422.00000 | 22.71897 | 18.35909 | -0.1444 | 8.35456 |
April | 405.00000 | 22.72357 | 22.61628 | -0.1469 | 8.04954 |
May | 418.00000 | 23.69686 | 26.24381 | -0.7406 | 17.90762 |
June | 408.00000 | 23.88884 | 33.53515 | -0.4536 | 9.57920 |
July | 415.00000 | 23.88922 | 36.36900 | -0.4303 | 9.15870 |
August | 422.00000 | 23.88954 | 34.59288 | -0.4180 | 8.95202 |
September | 405.00000 | 23.85574 | 25.95320 | -0.4812 | 10.67991 |
October | 414.00000 | 23.22928 | 19.76539 | 0.09321 | 8.03764 |
November | 399.00000 | 23.07847 | 20.97011 | 0.03250 | 7.56596 |
December | 415.00000 | 22.52949 | 14.64610 | -0.2035 | 9.18254 |
Annual Sum or Average | 4913.00000 | 23.24358 | 24.32168 | -0.2650 | 9.55163 |
Minimum of Months | 376.00000 | 22.52949 | 14.64610 | -0.7406 | 7.56596 |
Maximum of Months | 422.00000 | 23.88954 | 36.36900 | 0.09321 | 17.90762 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.21372 | 21.35086 | -0.2340 | 8.84764 |
February | 376.00000 | 22.06127 | 18.92534 | -0.3143 | 10.12419 |
March | 422.00000 | 22.23587 | 19.23548 | -0.2743 | 9.43036 |
April | 405.00000 | 22.16496 | 23.81276 | -0.2907 | 9.27001 |
May | 418.00000 | 23.35773 | 27.51095 | -0.8895 | 23.84090 |
June | 408.00000 | 23.87790 | 33.87458 | -0.5029 | 10.60576 |
July | 415.00000 | 23.88314 | 36.79519 | -0.4729 | 9.98050 |
August | 422.00000 | 23.88252 | 34.91136 | -0.4607 | 9.75265 |
September | 405.00000 | 23.79898 | 26.30869 | -0.5386 | 12.19501 |
October | 414.00000 | 22.92784 | 20.68025 | 0.00022 | 8.19682 |
November | 399.00000 | 22.55609 | 22.13838 | -0.1035 | 8.07250 |
December | 415.00000 | 22.05474 | 15.43535 | -0.3311 | 10.35168 |
Annual Sum or Average | 4913.00000 | 22.92506 | 25.13642 | -0.3690 | 10.91046 |
Minimum of Months | 376.00000 | 22.05474 | 15.43535 | -0.8895 | 8.07250 |
Maximum of Months | 422.00000 | 23.88314 | 36.79519 | 0.00022 | 23.84090 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.146690E+09 | 39952708.71 | 31.74 | 0.146690E+09 | 0.00 | 0.00 | 0.36 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 4716.25 | 14-MAR-13:10 | 4716.25 | 14-MAR-13:10 | 0.00 | 15-MAR-13:50 | 1281.83 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
April | 23132292.36 | 6406455.18 | 26.77 | 23132254.37 | 37.99 | 0.00 | 0.19 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 2414.50 | 20-APR-13:00 | 2414.50 | 20-APR-13:00 | 0.02 | 28-APR-15:00 | 660.74 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
May | 0.188581E+10 | 0.509022E+09 | 181.87 | 0.185561E+10 | 30197109.20 | 0.00 | 0.66 | 31-MAY-15:00 | 0.00 | 01-MAY-00:10 | 9844.12 | 31-MAY-15:00 | 9258.08 | 17-MAY-14:10 | 843.54 | 31-MAY-16:00 | 2637.16 | 31-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.125443E+11 | 0.335254E+10 | 398.87 | 0.117761E+11 | 0.768190E+09 | 0.00 | 1.00 | 04-JUN-20:04 | 0.00 | 01-JUN-00:10 | 35168.36 | 18-JUN-18:18 | 32760.16 | 27-JUN-20:51 | 12083.58 | 19-JUN-22:05 | 7733.25 | 26-JUN-20:10 | 0.00 | 01-JUN-00:10 |
July | 0.133289E+11 | 0.354278E+10 | 414.60 | 0.122667E+11 | 0.106213E+10 | 0.00 | 1.00 | 01-JUL-21:22 | 0.00 | 01-JUL-00:01 | 35502.68 | 23-JUL-21:04 | 32815.08 | 18-JUL-20:52 | 17412.96 | 27-JUL-20:33 | 7726.48 | 24-JUL-20:52 | 0.00 | 01-JUL-00:01 |
August | 0.124692E+11 | 0.327814E+10 | 402.95 | 0.116139E+11 | 0.855245E+09 | 0.00 | 1.00 | 02-AUG-21:31 | 0.00 | 01-AUG-00:10 | 36020.08 | 04-AUG-02:15 | 32769.42 | 15-AUG-20:12 | 19291.12 | 04-AUG-02:15 | 7631.63 | 04-AUG-02:15 | 0.00 | 01-AUG-00:10 |
September | 0.810287E+10 | 0.212645E+10 | 332.90 | 0.793557E+10 | 0.167304E+09 | 0.00 | 1.00 | 01-SEP-20:45 | 0.00 | 01-SEP-00:05 | 33781.56 | 02-SEP-21:41 | 33019.51 | 12-SEP-20:55 | 7649.22 | 01-SEP-20:45 | 7326.15 | 12-SEP-20:12 | 0.00 | 01-SEP-00:05 |
October | 0.583721E+09 | 0.155146E+09 | 97.36 | 0.583720E+09 | 201.71 | 0.00 | 0.65 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 9189.32 | 11-OCT-14:10 | 9189.32 | 11-OCT-14:10 | 0.09 | 03-OCT-12:00 | 2435.63 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
November | 29319457.73 | 8098142.07 | 14.83 | 29319457.63 | 0.11 | 0.00 | 0.19 | 07-NOV-15:10 | 0.00 | 01-NOV-00:05 | 2379.69 | 07-NOV-15:10 | 2379.69 | 07-NOV-15:10 | 0.00 | 09-NOV-18:25 | 649.71 | 07-NOV-15:10 | 0.00 | 01-NOV-00:05 |
December | 155.27 | 44.54 | 0.50 | 155.27 | 0.00 | 0.00 | 0.00 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 0.24 | 02-DEC-15:00 | 0.24 | 02-DEC-15:00 | 0.00 | 02-DEC-15:05 | 0.07 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.491139E+11 | 0.130185E+11 | 1902.40 | 0.462308E+11 | 0.288307E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.133289E+11 | 0.354278E+10 | 414.60 | 0.122667E+11 | 0.106213E+10 | 0.00 | 1.00 | 0.00 | 36020.08 | 33019.51 | 19291.12 | 7733.25 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 90272998.58 | 27544224.43 | 11.91 | 90272998.58 | 0.00 | 0.00 | 0.18 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 10205.61 | 20-JAN-14:00 | 10205.61 | 20-JAN-14:00 | 0.00 | 20-JAN-12:03 | 3082.40 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
February | 66109967.91 | 20265931.96 | 8.50 | 66109967.91 | 0.00 | 0.00 | 0.15 | 18-FEB-13:50 | 0.00 | 01-FEB-00:10 | 8667.93 | 18-FEB-13:50 | 8667.93 | 18-FEB-13:50 | 0.00 | 18-FEB-12:50 | 2635.40 | 18-FEB-13:50 | 0.00 | 01-FEB-00:10 |
March | 0.241301E+10 | 0.692755E+09 | 65.26 | 0.241301E+10 | 0.00 | 0.00 | 0.62 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 74135.67 | 14-MAR-20:25 | 74135.67 | 14-MAR-20:25 | 0.00 | 14-MAR-12:10 | 17564.01 | 14-MAR-20:25 | 0.00 | 01-MAR-00:10 |
April | 0.131958E+10 | 0.392821E+09 | 64.97 | 0.131951E+10 | 76376.02 | 0.00 | 0.38 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 23382.28 | 20-APR-13:00 | 23382.28 | 20-APR-13:00 | 56.21 | 13-APR-13:10 | 6787.88 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
May | 0.164855E+11 | 0.474088E+10 | 238.33 | 0.162353E+11 | 0.250239E+09 | 0.00 | 1.00 | 10-MAY-20:20 | 0.00 | 01-MAY-00:10 | 150396.55 | 31-MAY-20:20 | 148578.22 | 10-MAY-20:20 | 27736.28 | 31-MAY-21:10 | 35669.99 | 31-MAY-20:20 | 0.00 | 01-MAY-00:10 |
June | 0.713310E+11 | 0.206382E+11 | 418.47 | 0.670681E+11 | 0.426292E+10 | 0.00 | 1.00 | 01-JUN-20:15 | 0.00 | 01-JUN-00:10 | 160053.75 | 18-JUN-18:11 | 150145.20 | 11-JUN-18:51 | 74026.11 | 20-JUN-20:12 | 40706.19 | 26-JUN-20:10 | 0.00 | 01-JUN-00:10 |
July | 0.736971E+11 | 0.212718E+11 | 432.43 | 0.679357E+11 | 0.576135E+10 | 0.00 | 1.00 | 01-JUL-00:10 | 0.00 | 01-JUL-00:01 | 163825.21 | 30-JUL-20:55 | 149502.44 | 14-JUL-21:33 | 83940.64 | 30-JUL-20:55 | 39232.08 | 24-JUL-20:52 | 0.00 | 01-JUL-00:01 |
August | 0.690272E+11 | 0.197290E+11 | 419.02 | 0.646676E+11 | 0.435961E+10 | 0.00 | 1.00 | 01-AUG-20:15 | 0.00 | 01-AUG-00:10 | 164202.15 | 04-AUG-02:20 | 149357.97 | 23-AUG-20:15 | 87719.75 | 04-AUG-02:20 | 38833.04 | 04-AUG-02:20 | 0.00 | 01-AUG-00:10 |
September | 0.453263E+11 | 0.129272E+11 | 349.92 | 0.444967E+11 | 0.829577E+09 | 0.00 | 1.00 | 01-SEP-00:43 | 0.00 | 01-SEP-00:05 | 153912.66 | 02-SEP-21:56 | 150450.91 | 12-SEP-20:53 | 51639.55 | 01-SEP-01:32 | 37222.11 | 12-SEP-20:10 | 0.00 | 01-SEP-00:05 |
October | 0.569590E+10 | 0.164030E+10 | 127.76 | 0.569571E+10 | 193203.14 | 0.00 | 0.80 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 54102.05 | 11-OCT-14:10 | 54102.05 | 11-OCT-14:10 | 34.22 | 01-OCT-13:40 | 15286.62 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
November | 0.856481E+09 | 0.255509E+09 | 29.40 | 0.856481E+09 | 11.85 | 0.00 | 0.38 | 07-NOV-15:10 | 0.00 | 01-NOV-00:05 | 23204.87 | 07-NOV-15:10 | 23204.87 | 07-NOV-15:10 | 0.02 | 09-NOV-18:55 | 6721.38 | 07-NOV-15:10 | 0.00 | 01-NOV-00:05 |
December | 0.172615E+09 | 52844699.37 | 11.93 | 0.172615E+09 | 0.00 | 0.00 | 0.24 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 14428.55 | 02-DEC-15:00 | 14428.55 | 02-DEC-15:00 | 0.00 | 02-DEC-15:10 | 4347.54 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.286481E+12 | 0.823891E+11 | 2177.90 | 0.271017E+12 | 0.154640E+11 | 0.00 | ||||||||||||||
Minimum of Months | 66109967.91 | 20265931.96 | 8.50 | 66109967.91 | 0.00 | 0.00 | 0.15 | 0.00 | 8667.93 | 8667.93 | 0.00 | 2635.40 | 0.00 | |||||||
Maximum of Months | 0.736971E+11 | 0.212718E+11 | 432.43 | 0.679357E+11 | 0.576135E+10 | 0.00 | 1.00 | 0.00 | 164202.15 | 150450.91 | 87719.75 | 40706.19 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.301363E+09 | 70450292.44 | 83.54 | 0.301363E+09 | 249.85 | 0.00 | 0.78 | 20-JAN-13:50 | 0.00 | 01-JAN-00:10 | 8158.34 | 20-JAN-13:50 | 8158.34 | 20-JAN-13:50 | 0.03 | 28-JAN-12:50 | 1753.90 | 20-JAN-13:50 | 0.00 | 01-JAN-00:10 |
February | 0.125968E+09 | 29848870.64 | 67.65 | 0.125968E+09 | 24.20 | 0.00 | 0.69 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 | 6974.39 | 18-FEB-14:00 | 6974.39 | 18-FEB-14:00 | 0.04 | 19-FEB-16:20 | 1543.07 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 |
March | 0.802094E+09 | 0.184929E+09 | 109.16 | 0.802094E+09 | 516.72 | 0.00 | 0.98 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 10824.90 | 14-MAR-13:00 | 10824.90 | 14-MAR-13:00 | 0.68 | 17-MAR-16:20 | 2300.74 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
April | 0.360085E+09 | 87805764.66 | 99.71 | 0.360032E+09 | 53538.46 | 0.00 | 0.59 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 5823.40 | 20-APR-13:00 | 5823.40 | 20-APR-13:00 | 39.82 | 28-APR-14:10 | 1346.41 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
May | 0.258202E+10 | 0.619681E+09 | 259.26 | 0.256442E+10 | 17595075.14 | 0.00 | 1.00 | 10-MAY-20:20 | 0.00 | 01-MAY-00:10 | 20802.93 | 31-MAY-20:15 | 20559.04 | 10-MAY-20:20 | 3337.90 | 31-MAY-20:15 | 4414.69 | 31-MAY-20:15 | 0.00 | 01-MAY-00:10 |
June | 0.106149E+11 | 0.261349E+10 | 411.96 | 0.101736E+11 | 0.441284E+09 | 0.00 | 1.00 | 01-JUN-20:11 | 0.00 | 01-JUN-00:10 | 22150.21 | 18-JUN-18:11 | 20653.69 | 23-JUN-20:10 | 10179.05 | 20-JUN-20:12 | 4754.48 | 18-JUN-18:11 | 0.00 | 01-JUN-00:10 |
July | 0.115398E+11 | 0.281215E+10 | 428.25 | 0.108478E+11 | 0.692003E+09 | 0.00 | 1.00 | 01-JUL-00:01 | 0.00 | 01-JUL-00:02 | 22652.23 | 29-JUL-21:20 | 20739.47 | 18-JUL-20:41 | 11250.98 | 31-JUL-20:15 | 4810.57 | 24-JUL-21:08 | 0.00 | 01-JUL-00:01 |
August | 0.114330E+11 | 0.274287E+10 | 428.36 | 0.109280E+11 | 0.505035E+09 | 0.00 | 1.00 | 01-AUG-20:11 | 0.00 | 01-AUG-00:10 | 22825.92 | 04-AUG-01:30 | 20845.00 | 25-AUG-20:41 | 12176.58 | 04-AUG-01:30 | 4839.24 | 02-AUG-20:41 | 0.00 | 01-AUG-00:10 |
September | 0.924288E+10 | 0.214538E+10 | 371.51 | 0.914694E+10 | 95935402.28 | 0.00 | 1.00 | 01-SEP-00:15 | 0.00 | 01-SEP-00:05 | 21216.27 | 02-SEP-22:21 | 20761.03 | 12-SEP-20:08 | 6108.30 | 01-SEP-01:10 | 4620.47 | 03-SEP-18:10 | 0.00 | 01-SEP-00:05 |
October | 0.216169E+10 | 0.487817E+09 | 194.62 | 0.216133E+10 | 355392.30 | 0.00 | 1.00 | 01-OCT-18:10 | 0.00 | 01-OCT-00:10 | 20559.04 | 01-OCT-18:10 | 20559.04 | 09-OCT-18:10 | 1465.88 | 01-OCT-18:10 | 4352.65 | 01-OCT-18:10 | 0.00 | 01-OCT-00:10 |
November | 0.742276E+09 | 0.166731E+09 | 108.89 | 0.742273E+09 | 3451.49 | 0.00 | 1.00 | 05-NOV-18:10 | 0.00 | 01-NOV-00:05 | 20559.04 | 05-NOV-18:10 | 20559.04 | 05-NOV-18:10 | 1.58 | 10-NOV-13:20 | 4352.65 | 05-NOV-18:10 | 0.00 | 01-NOV-00:05 |
December | 0.377811E+09 | 88383511.55 | 73.90 | 0.377811E+09 | 0.00 | 0.00 | 0.81 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 8547.97 | 02-DEC-15:00 | 8547.97 | 02-DEC-15:00 | 0.00 | 02-DEC-11:50 | 1848.34 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.502839E+11 | 0.120495E+11 | 2636.81 | 0.485317E+11 | 0.175227E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.125968E+09 | 29848870.64 | 67.65 | 0.125968E+09 | 0.00 | 0.00 | 0.59 | 0.00 | 5823.40 | 5823.40 | 0.00 | 1346.41 | 0.00 | |||||||
Maximum of Months | 0.115398E+11 | 0.281215E+10 | 428.36 | 0.109280E+11 | 0.692003E+09 | 0.00 | 1.00 | 0.00 | 22825.92 | 20845.00 | 12176.58 | 4839.24 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.178969E+09 | 41009289.18 | 45.43 | 0.178969E+09 | 29.54 | 0.00 | 0.73 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 5969.57 | 20-JAN-14:00 | 5969.57 | 20-JAN-14:00 | 0.01 | 27-JAN-13:50 | 1265.66 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
February | 67924651.05 | 15651655.09 | 35.17 | 67924651.05 | 0.00 | 0.00 | 0.63 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 | 5023.07 | 18-FEB-14:00 | 5023.07 | 18-FEB-14:00 | 0.00 | 18-FEB-13:50 | 1096.76 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 |
March | 0.489383E+09 | 0.109758E+09 | 78.53 | 0.489383E+09 | 0.00 | 0.00 | 0.95 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 8244.08 | 14-MAR-13:00 | 8244.08 | 14-MAR-13:00 | 0.00 | 14-MAR-12:10 | 1718.84 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
April | 0.142306E+09 | 34462262.41 | 63.64 | 0.142305E+09 | 201.88 | 0.00 | 0.49 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 3694.73 | 20-APR-13:00 | 3694.73 | 20-APR-13:00 | 0.06 | 28-APR-14:50 | 855.03 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
May | 0.143649E+10 | 0.343636E+09 | 201.06 | 0.143126E+10 | 5227480.76 | 0.00 | 0.82 | 17-MAY-13:40 | 0.00 | 01-MAY-00:10 | 6675.09 | 17-MAY-13:30 | 6675.09 | 17-MAY-13:30 | 183.89 | 30-MAY-16:00 | 1617.18 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 |
June | 0.759472E+10 | 0.184537E+10 | 386.76 | 0.730317E+10 | 0.291549E+09 | 0.00 | 1.00 | 01-JUN-20:16 | 0.00 | 01-JUN-00:10 | 17569.63 | 18-JUN-18:11 | 16371.31 | 14-JUN-20:41 | 6923.04 | 21-JUN-21:23 | 3662.99 | 18-JUN-18:11 | 0.00 | 01-JUN-00:10 |
July | 0.829152E+10 | 0.199141E+10 | 410.54 | 0.784104E+10 | 0.450484E+09 | 0.00 | 1.00 | 01-JUL-00:19 | 0.00 | 01-JUL-00:01 | 18011.50 | 29-JUL-21:45 | 16454.61 | 18-JUL-20:41 | 8972.26 | 31-JUL-20:33 | 3709.01 | 24-JUL-21:08 | 0.00 | 01-JUL-00:01 |
August | 0.841572E+10 | 0.198150E+10 | 405.54 | 0.807284E+10 | 0.342885E+09 | 0.00 | 1.00 | 01-AUG-20:16 | 0.00 | 01-AUG-00:10 | 17990.23 | 04-AUG-00:42 | 16510.26 | 25-AUG-20:41 | 9151.56 | 04-AUG-00:42 | 3734.19 | 02-AUG-20:41 | 0.00 | 01-AUG-00:10 |
September | 0.690519E+10 | 0.156822E+10 | 348.56 | 0.684024E+10 | 64948636.61 | 0.00 | 1.00 | 01-SEP-00:15 | 0.00 | 01-SEP-00:05 | 16826.75 | 02-SEP-21:49 | 16472.22 | 12-SEP-20:08 | 4840.09 | 01-SEP-22:50 | 3561.51 | 03-SEP-18:10 | 0.00 | 01-SEP-00:05 |
October | 0.155841E+10 | 0.342062E+09 | 161.99 | 0.155831E+10 | 99847.82 | 0.00 | 1.00 | 08-OCT-18:10 | 0.00 | 01-OCT-00:10 | 16318.41 | 08-OCT-18:10 | 16318.41 | 10-OCT-20:10 | 450.65 | 08-OCT-18:10 | 3355.27 | 08-OCT-18:10 | 0.00 | 01-OCT-00:10 |
November | 0.517561E+09 | 0.113073E+09 | 80.57 | 0.517560E+09 | 260.32 | 0.00 | 0.96 | 07-NOV-14:00 | 0.00 | 01-NOV-00:05 | 8399.81 | 07-NOV-14:00 | 8399.81 | 07-NOV-14:00 | 0.07 | 04-NOV-13:50 | 1682.57 | 07-NOV-14:00 | 0.00 | 01-NOV-00:05 |
December | 0.221786E+09 | 50968536.42 | 44.51 | 0.221786E+09 | 0.00 | 0.00 | 0.77 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 6353.75 | 02-DEC-15:00 | 6353.75 | 02-DEC-15:00 | 0.00 | 01-DEC-15:05 | 1351.74 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.358200E+11 | 0.843712E+10 | 2262.30 | 0.346648E+11 | 0.115519E+10 | 0.00 | ||||||||||||||
Minimum of Months | 67924651.05 | 15651655.09 | 35.17 | 67924651.05 | 0.00 | 0.00 | 0.49 | 0.00 | 3694.73 | 3694.73 | 0.00 | 855.03 | 0.00 | |||||||
Maximum of Months | 0.841572E+10 | 0.199141E+10 | 410.54 | 0.807284E+10 | 0.450484E+09 | 0.00 | 1.00 | 0.00 | 18011.50 | 16510.26 | 9151.56 | 3734.19 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 40.11 | 28.56 | 11.55 | 35.53 | 118.48 | 4.67 | 0.00 | 744.00 |
February | 57.78 | 44.18 | 13.60 | 58.17 | 120.74 | 6.67 | 0.00 | 672.00 |
March | 75.53 | 52.69 | 22.84 | 87.34 | 97.88 | 22.50 | 0.00 | 744.00 |
April | 83.54 | 49.31 | 34.22 | 97.21 | 86.27 | 27.83 | 0.00 | 720.00 |
May | 105.23 | 56.06 | 49.18 | 140.93 | 54.54 | 2.17 | 0.00 | 744.00 |
June | 131.74 | 91.92 | 39.83 | 205.22 | 34.55 | 0.00 | 0.00 | 720.00 |
July | 113.94 | 67.72 | 46.22 | 178.86 | 30.99 | 0.00 | 0.00 | 744.00 |
August | 113.38 | 80.89 | 32.49 | 176.77 | 35.47 | 2.50 | 0.00 | 744.00 |
September | 89.85 | 60.38 | 29.47 | 132.04 | 52.92 | 2.00 | 0.00 | 720.00 |
October | 63.59 | 44.94 | 18.64 | 75.84 | 97.97 | 1.00 | 0.00 | 744.00 |
November | 46.45 | 33.61 | 12.84 | 48.28 | 110.50 | 4.17 | 0.00 | 720.00 |
December | 34.02 | 22.54 | 11.48 | 25.60 | 136.91 | 5.50 | 0.00 | 744.00 |
Annual Sum or Average | 79.68 | 52.74 | 26.95 | 105.37 | 81.23 | 79.00 | 0.00 | 8760.00 |
Minimum of Months | 34.02 | 22.54 | 11.48 | 25.60 | 30.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 131.74 | 91.92 | 49.18 | 205.22 | 136.91 | 27.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2302.78 | 1894.31 | 408.47 | 2435.21 | 1216.85 | 0.00 | 0.00 | 744.00 |
February | 2209.89 | 1762.11 | 447.78 | 2204.90 | 1266.15 | 0.00 | 0.00 | 672.00 |
March | 1628.96 | 1071.95 | 557.00 | 1472.03 | 1025.34 | 0.00 | 0.00 | 744.00 |
April | 1054.49 | 423.91 | 630.58 | 715.34 | 922.69 | 0.00 | 0.00 | 720.00 |
May | 966.33 | 177.00 | 789.34 | 715.38 | 565.38 | 0.00 | 0.00 | 744.00 |
June | 890.75 | 162.54 | 728.21 | 890.94 | 306.95 | 0.00 | 0.00 | 720.00 |
July | 927.38 | 165.90 | 761.48 | 969.09 | 274.70 | 0.00 | 0.00 | 744.00 |
August | 1180.80 | 493.50 | 687.30 | 1142.71 | 321.51 | 0.00 | 0.00 | 744.00 |
September | 1519.55 | 847.94 | 671.62 | 1584.21 | 505.10 | 0.00 | 0.00 | 720.00 |
October | 1817.88 | 1290.13 | 527.75 | 1862.00 | 1048.86 | 0.00 | 0.00 | 744.00 |
November | 2214.14 | 1765.10 | 449.04 | 2363.55 | 1179.74 | 0.00 | 0.00 | 720.00 |
December | 2116.55 | 1713.07 | 403.48 | 2215.41 | 1371.08 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1565.50 | 976.18 | 589.32 | 1543.90 | 831.29 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 890.75 | 162.54 | 403.48 | 715.34 | 274.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 2302.78 | 1894.31 | 789.34 | 2435.21 | 1371.08 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2302.78 | 1894.31 | 408.47 | 2445.26 | 1183.15 | 0.00 | 0.00 | 744.00 |
February | 2209.89 | 1762.11 | 447.78 | 2213.83 | 1236.21 | 0.00 | 0.00 | 672.00 |
March | 1628.96 | 1071.95 | 557.00 | 1480.04 | 995.95 | 0.00 | 0.00 | 744.00 |
April | 1054.49 | 423.91 | 630.58 | 724.41 | 888.98 | 0.00 | 0.00 | 720.00 |
May | 966.33 | 177.00 | 789.34 | 723.92 | 540.83 | 0.00 | 0.00 | 744.00 |
June | 890.75 | 162.54 | 728.21 | 888.08 | 301.36 | 0.00 | 0.00 | 720.00 |
July | 927.38 | 165.90 | 761.48 | 965.24 | 271.87 | 0.00 | 0.00 | 744.00 |
August | 1180.80 | 493.50 | 687.30 | 1138.34 | 319.71 | 0.00 | 0.00 | 744.00 |
September | 1519.55 | 847.94 | 671.62 | 1581.07 | 500.55 | 0.00 | 0.00 | 720.00 |
October | 1817.88 | 1290.13 | 527.75 | 1864.91 | 1026.88 | 0.00 | 0.00 | 744.00 |
November | 2214.14 | 1765.10 | 449.04 | 2371.38 | 1147.17 | 0.00 | 0.00 | 720.00 |
December | 2116.55 | 1713.07 | 403.48 | 2222.38 | 1341.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1565.50 | 976.18 | 589.32 | 1547.88 | 810.50 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 890.75 | 162.54 | 403.48 | 723.92 | 271.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 2302.78 | 1894.31 | 789.34 | 2445.26 | 1341.51 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 473.83 | 389.78 | 84.05 | 495.62 | 238.75 | 0.00 | 0.00 | 744.00 |
February | 454.72 | 362.58 | 92.14 | 448.29 | 252.07 | 0.00 | 0.00 | 672.00 |
March | 335.18 | 220.57 | 114.61 | 301.06 | 202.54 | 0.00 | 0.00 | 744.00 |
April | 216.98 | 87.23 | 129.75 | 147.57 | 180.51 | 0.00 | 0.00 | 720.00 |
May | 198.84 | 36.42 | 162.42 | 149.58 | 106.21 | 0.00 | 0.00 | 744.00 |
June | 183.28 | 33.44 | 149.84 | 168.19 | 64.08 | 0.00 | 0.00 | 720.00 |
July | 190.82 | 34.14 | 156.69 | 182.45 | 58.59 | 0.00 | 0.00 | 744.00 |
August | 242.97 | 101.54 | 141.42 | 221.02 | 69.30 | 0.00 | 0.00 | 744.00 |
September | 312.67 | 174.47 | 138.20 | 314.88 | 105.37 | 0.00 | 0.00 | 720.00 |
October | 374.06 | 265.46 | 108.59 | 381.08 | 206.36 | 0.00 | 0.00 | 744.00 |
November | 455.59 | 363.20 | 92.40 | 481.57 | 230.63 | 0.00 | 0.00 | 720.00 |
December | 435.51 | 352.49 | 83.02 | 449.08 | 273.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 322.12 | 200.86 | 121.26 | 310.95 | 165.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 183.28 | 33.44 | 83.02 | 147.57 | 58.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 473.83 | 389.78 | 162.42 | 495.62 | 273.25 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.107421E+09 | 76489530.04 | 30931898.32 | 95172219.37 | 0.317350E+09 |
February | 0.139782E+09 | 0.106871E+09 | 32911664.78 | 0.140725E+09 | 0.292096E+09 |
March | 0.202294E+09 | 0.141115E+09 | 61178904.02 | 0.233935E+09 | 0.262157E+09 |
April | 0.216525E+09 | 0.127817E+09 | 88708144.13 | 0.251978E+09 | 0.223612E+09 |
May | 0.281861E+09 | 0.150140E+09 | 0.131721E+09 | 0.377471E+09 | 0.146070E+09 |
June | 0.341482E+09 | 0.238255E+09 | 0.103227E+09 | 0.531933E+09 | 89562394.41 |
July | 0.305164E+09 | 0.181380E+09 | 0.123784E+09 | 0.479055E+09 | 83013369.74 |
August | 0.303669E+09 | 0.216654E+09 | 87014825.46 | 0.473455E+09 | 95002175.06 |
September | 0.232886E+09 | 0.156497E+09 | 76389314.50 | 0.342255E+09 | 0.137161E+09 |
October | 0.170316E+09 | 0.120380E+09 | 49936024.74 | 0.203130E+09 | 0.262399E+09 |
November | 0.120394E+09 | 87118743.93 | 33275696.24 | 0.125144E+09 | 0.286412E+09 |
December | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 0.366708E+09 |
Annual Sum or Average | 0.251292E+10 | 0.166310E+10 | 0.849818E+09 | 0.332283E+10 | 0.256154E+10 |
Minimum of Months | 91121952.72 | 60381956.72 | 30739995.99 | 68573931.79 | 83013369.74 |
Maximum of Months | 0.341482E+09 | 0.238255E+09 | 0.131721E+09 | 0.531933E+09 | 0.366708E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.616776E+10 | 0.507371E+10 | 0.109405E+10 | 0.652245E+10 | 0.325921E+10 |
February | 0.534616E+10 | 0.426289E+10 | 0.108326E+10 | 0.533408E+10 | 0.306308E+10 |
March | 0.436300E+10 | 0.287112E+10 | 0.149188E+10 | 0.394268E+10 | 0.274628E+10 |
April | 0.273324E+10 | 0.109877E+10 | 0.163447E+10 | 0.185415E+10 | 0.239162E+10 |
May | 0.258823E+10 | 0.474064E+09 | 0.211417E+10 | 0.191607E+10 | 0.151433E+10 |
June | 0.230882E+10 | 0.421302E+09 | 0.188752E+10 | 0.230932E+10 | 0.795603E+09 |
July | 0.248390E+10 | 0.444346E+09 | 0.203955E+10 | 0.259561E+10 | 0.735746E+09 |
August | 0.316266E+10 | 0.132179E+10 | 0.184087E+10 | 0.306064E+10 | 0.861139E+09 |
September | 0.393868E+10 | 0.219785E+10 | 0.174083E+10 | 0.410627E+10 | 0.130923E+10 |
October | 0.486902E+10 | 0.345548E+10 | 0.141354E+10 | 0.498719E+10 | 0.280927E+10 |
November | 0.573904E+10 | 0.457514E+10 | 0.116390E+10 | 0.612633E+10 | 0.305788E+10 |
December | 0.566897E+10 | 0.458828E+10 | 0.108069E+10 | 0.593375E+10 | 0.367231E+10 |
Annual Sum or Average | 0.493695E+11 | 0.307848E+11 | 0.185847E+11 | 0.486886E+11 | 0.262157E+11 |
Minimum of Months | 0.230882E+10 | 0.421302E+09 | 0.108069E+10 | 0.185415E+10 | 0.735746E+09 |
Maximum of Months | 0.616776E+10 | 0.507371E+10 | 0.211417E+10 | 0.652245E+10 | 0.367231E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.616776E+10 | 0.507371E+10 | 0.109405E+10 | 0.654938E+10 | 0.316896E+10 |
February | 0.534616E+10 | 0.426289E+10 | 0.108326E+10 | 0.535569E+10 | 0.299064E+10 |
March | 0.436300E+10 | 0.287112E+10 | 0.149188E+10 | 0.396413E+10 | 0.266756E+10 |
April | 0.273324E+10 | 0.109877E+10 | 0.163447E+10 | 0.187766E+10 | 0.230424E+10 |
May | 0.258823E+10 | 0.474064E+09 | 0.211417E+10 | 0.193894E+10 | 0.144856E+10 |
June | 0.230882E+10 | 0.421302E+09 | 0.188752E+10 | 0.230190E+10 | 0.781138E+09 |
July | 0.248390E+10 | 0.444346E+09 | 0.203955E+10 | 0.258529E+10 | 0.728172E+09 |
August | 0.316266E+10 | 0.132179E+10 | 0.184087E+10 | 0.304893E+10 | 0.856310E+09 |
September | 0.393868E+10 | 0.219785E+10 | 0.174083E+10 | 0.409813E+10 | 0.129743E+10 |
October | 0.486902E+10 | 0.345548E+10 | 0.141354E+10 | 0.499497E+10 | 0.275038E+10 |
November | 0.573904E+10 | 0.457514E+10 | 0.116390E+10 | 0.614660E+10 | 0.297348E+10 |
December | 0.566897E+10 | 0.458828E+10 | 0.108069E+10 | 0.595243E+10 | 0.359309E+10 |
Annual Sum or Average | 0.493695E+11 | 0.307848E+11 | 0.185847E+11 | 0.488141E+11 | 0.255600E+11 |
Minimum of Months | 0.230882E+10 | 0.421302E+09 | 0.108069E+10 | 0.187766E+10 | 0.728172E+09 |
Maximum of Months | 0.616776E+10 | 0.507371E+10 | 0.211417E+10 | 0.654938E+10 | 0.359309E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126911E+10 | 0.104399E+10 | 0.225117E+09 | 0.132748E+10 | 0.639474E+09 |
February | 0.110005E+10 | 0.877153E+09 | 0.222897E+09 | 0.108451E+10 | 0.609810E+09 |
March | 0.897752E+09 | 0.590775E+09 | 0.306976E+09 | 0.806354E+09 | 0.542491E+09 |
April | 0.562404E+09 | 0.226087E+09 | 0.336317E+09 | 0.382508E+09 | 0.467881E+09 |
May | 0.532566E+09 | 97545612.91 | 0.435021E+09 | 0.400623E+09 | 0.284462E+09 |
June | 0.475073E+09 | 86689014.65 | 0.388384E+09 | 0.435948E+09 | 0.166107E+09 |
July | 0.511098E+09 | 91430603.58 | 0.419667E+09 | 0.488673E+09 | 0.156917E+09 |
August | 0.650763E+09 | 0.271978E+09 | 0.378785E+09 | 0.591974E+09 | 0.185604E+09 |
September | 0.810441E+09 | 0.452239E+09 | 0.358202E+09 | 0.816158E+09 | 0.273122E+09 |
October | 0.100187E+10 | 0.711016E+09 | 0.290856E+09 | 0.102069E+10 | 0.552714E+09 |
November | 0.118089E+10 | 0.941402E+09 | 0.239489E+09 | 0.124824E+10 | 0.597798E+09 |
December | 0.116647E+10 | 0.944106E+09 | 0.222368E+09 | 0.120281E+10 | 0.731876E+09 |
Annual Sum or Average | 0.101585E+11 | 0.633441E+10 | 0.382408E+10 | 0.980597E+10 | 0.520826E+10 |
Minimum of Months | 0.475073E+09 | 86689014.65 | 0.222368E+09 | 0.382508E+09 | 0.156917E+09 |
Maximum of Months | 0.126911E+10 | 0.104399E+10 | 0.435021E+09 | 0.132748E+10 | 0.731876E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 568.53 | 1895.76 | 641.71 | 456.93 | 184.78 | 0.00 | 0.00 |
February | 930.72 | 1931.85 | 924.49 | 706.82 | 217.67 | 0.00 | 0.00 |
March | 1397.46 | 1566.05 | 1208.45 | 842.98 | 365.47 | 0.00 | 0.00 |
April | 1555.42 | 1380.32 | 1336.57 | 788.99 | 547.58 | 0.00 | 0.00 |
May | 2254.91 | 872.58 | 1683.76 | 896.89 | 786.86 | 0.00 | 0.00 |
June | 3283.54 | 552.85 | 2107.92 | 1470.71 | 637.21 | 0.00 | 0.00 |
July | 2861.74 | 495.90 | 1822.96 | 1083.51 | 739.45 | 0.00 | 0.00 |
August | 2828.28 | 567.52 | 1814.03 | 1294.23 | 519.80 | 0.00 | 0.00 |
September | 2112.69 | 846.67 | 1437.57 | 966.03 | 471.54 | 0.00 | 0.00 |
October | 1213.44 | 1567.50 | 1017.42 | 719.11 | 298.30 | 0.00 | 0.00 |
November | 772.49 | 1767.98 | 743.18 | 537.77 | 205.41 | 0.00 | 0.00 |
December | 409.64 | 2190.61 | 544.34 | 360.70 | 183.63 | 0.00 | 0.00 |
Annual Sum or Average | 1685.86 | 1299.62 | 1274.94 | 843.78 | 431.16 | 0.00 | 0.00 |
Minimum of Months | 409.64 | 495.90 | 544.34 | 360.70 | 183.63 | 0.00 | 0.00 |
Maximum of Months | 3283.54 | 2190.61 | 2107.92 | 1470.71 | 786.86 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2435.21 | 1216.85 | 2302.78 | 1894.31 | 408.47 | 0.00 | 0.00 |
February | 2204.90 | 1266.15 | 2209.89 | 1762.11 | 447.78 | 0.00 | 0.00 |
March | 1472.03 | 1025.34 | 1628.96 | 1071.95 | 557.00 | 0.00 | 0.00 |
April | 715.34 | 922.69 | 1054.49 | 423.91 | 630.58 | 0.00 | 0.00 |
May | 715.38 | 565.38 | 966.33 | 177.00 | 789.34 | 0.00 | 0.00 |
June | 890.94 | 306.95 | 890.75 | 162.54 | 728.21 | 0.00 | 0.00 |
July | 969.09 | 274.70 | 927.38 | 165.90 | 761.48 | 0.00 | 0.00 |
August | 1142.71 | 321.51 | 1180.80 | 493.50 | 687.30 | 0.00 | 0.00 |
September | 1584.21 | 505.10 | 1519.55 | 847.94 | 671.62 | 0.00 | 0.00 |
October | 1862.00 | 1048.86 | 1817.88 | 1290.13 | 527.75 | 0.00 | 0.00 |
November | 2363.55 | 1179.74 | 2214.14 | 1765.10 | 449.04 | 0.00 | 0.00 |
December | 2215.41 | 1371.08 | 2116.55 | 1713.07 | 403.48 | 0.00 | 0.00 |
Annual Sum or Average | 1543.90 | 831.29 | 1565.50 | 976.18 | 589.32 | 0.00 | 0.00 |
Minimum of Months | 715.34 | 274.70 | 890.75 | 162.54 | 403.48 | 0.00 | 0.00 |
Maximum of Months | 2435.21 | 1371.08 | 2302.78 | 1894.31 | 789.34 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2445.26 | 1183.15 | 2302.78 | 1894.31 | 408.47 | 0.00 | 0.00 |
February | 2213.83 | 1236.21 | 2209.89 | 1762.11 | 447.78 | 0.00 | 0.00 |
March | 1480.04 | 995.95 | 1628.96 | 1071.95 | 557.00 | 0.00 | 0.00 |
April | 724.41 | 888.98 | 1054.49 | 423.91 | 630.58 | 0.00 | 0.00 |
May | 723.92 | 540.83 | 966.33 | 177.00 | 789.34 | 0.00 | 0.00 |
June | 888.08 | 301.36 | 890.75 | 162.54 | 728.21 | 0.00 | 0.00 |
July | 965.24 | 271.87 | 927.38 | 165.90 | 761.48 | 0.00 | 0.00 |
August | 1138.34 | 319.71 | 1180.80 | 493.50 | 687.30 | 0.00 | 0.00 |
September | 1581.07 | 500.55 | 1519.55 | 847.94 | 671.62 | 0.00 | 0.00 |
October | 1864.91 | 1026.88 | 1817.88 | 1290.13 | 527.75 | 0.00 | 0.00 |
November | 2371.38 | 1147.17 | 2214.14 | 1765.10 | 449.04 | 0.00 | 0.00 |
December | 2222.38 | 1341.51 | 2116.55 | 1713.07 | 403.48 | 0.00 | 0.00 |
Annual Sum or Average | 1547.88 | 810.50 | 1565.50 | 976.18 | 589.32 | 0.00 | 0.00 |
Minimum of Months | 723.92 | 271.87 | 890.75 | 162.54 | 403.48 | 0.00 | 0.00 |
Maximum of Months | 2445.26 | 1341.51 | 2302.78 | 1894.31 | 789.34 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 495.62 | 238.75 | 473.83 | 389.78 | 84.05 | 0.00 | 0.00 |
February | 448.29 | 252.07 | 454.72 | 362.58 | 92.14 | 0.00 | 0.00 |
March | 301.06 | 202.54 | 335.18 | 220.57 | 114.61 | 0.00 | 0.00 |
April | 147.57 | 180.51 | 216.98 | 87.23 | 129.75 | 0.00 | 0.00 |
May | 149.58 | 106.21 | 198.84 | 36.42 | 162.42 | 0.00 | 0.00 |
June | 168.19 | 64.08 | 183.28 | 33.44 | 149.84 | 0.00 | 0.00 |
July | 182.45 | 58.59 | 190.82 | 34.14 | 156.69 | 0.00 | 0.00 |
August | 221.02 | 69.30 | 242.97 | 101.54 | 141.42 | 0.00 | 0.00 |
September | 314.88 | 105.37 | 312.67 | 174.47 | 138.20 | 0.00 | 0.00 |
October | 381.08 | 206.36 | 374.06 | 265.46 | 108.59 | 0.00 | 0.00 |
November | 481.57 | 230.63 | 455.59 | 363.20 | 92.40 | 0.00 | 0.00 |
December | 449.08 | 273.25 | 435.51 | 352.49 | 83.02 | 0.00 | 0.00 |
Annual Sum or Average | 310.95 | 165.15 | 322.12 | 200.86 | 121.26 | 0.00 | 0.00 |
Minimum of Months | 147.57 | 58.59 | 183.28 | 33.44 | 83.02 | 0.00 | 0.00 |
Maximum of Months | 495.62 | 273.25 | 473.83 | 389.78 | 162.42 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.152276E+10 | 0.507759E+10 | 0.171874E+10 | 0.122383E+10 | 0.494910E+09 | 0.00 | 0.00 |
February | 0.225160E+10 | 0.467354E+10 | 0.223652E+10 | 0.170993E+10 | 0.526587E+09 | 0.00 | 0.00 |
March | 0.374296E+10 | 0.419451E+10 | 0.323671E+10 | 0.225784E+10 | 0.978862E+09 | 0.00 | 0.00 |
April | 0.403165E+10 | 0.357779E+10 | 0.346440E+10 | 0.204507E+10 | 0.141933E+10 | 0.00 | 0.00 |
May | 0.603954E+10 | 0.233712E+10 | 0.450977E+10 | 0.240224E+10 | 0.210753E+10 | 0.00 | 0.00 |
June | 0.851093E+10 | 0.143300E+10 | 0.546372E+10 | 0.381208E+10 | 0.165164E+10 | 0.00 | 0.00 |
July | 0.766488E+10 | 0.132821E+10 | 0.488262E+10 | 0.290208E+10 | 0.198054E+10 | 0.00 | 0.00 |
August | 0.757528E+10 | 0.152003E+10 | 0.485870E+10 | 0.346646E+10 | 0.139224E+10 | 0.00 | 0.00 |
September | 0.547609E+10 | 0.219457E+10 | 0.372618E+10 | 0.250395E+10 | 0.122223E+10 | 0.00 | 0.00 |
October | 0.325008E+10 | 0.419839E+10 | 0.272505E+10 | 0.192607E+10 | 0.798976E+09 | 0.00 | 0.00 |
November | 0.200230E+10 | 0.458259E+10 | 0.192631E+10 | 0.139390E+10 | 0.532411E+09 | 0.00 | 0.00 |
December | 0.109718E+10 | 0.586733E+10 | 0.145795E+10 | 0.966111E+09 | 0.491840E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.531652E+11 | 0.409847E+11 | 0.402067E+11 | 0.266096E+11 | 0.135971E+11 | 0.00 | 0.00 |
Minimum of Months | 0.109718E+10 | 0.132821E+10 | 0.145795E+10 | 0.966111E+09 | 0.491840E+09 | 0.00 | 0.00 |
Maximum of Months | 0.851093E+10 | 0.586733E+10 | 0.546372E+10 | 0.381208E+10 | 0.210753E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.652245E+10 | 0.325921E+10 | 0.616776E+10 | 0.507371E+10 | 0.109405E+10 | 0.00 | 0.00 |
February | 0.533408E+10 | 0.306308E+10 | 0.534616E+10 | 0.426289E+10 | 0.108326E+10 | 0.00 | 0.00 |
March | 0.394268E+10 | 0.274628E+10 | 0.436300E+10 | 0.287112E+10 | 0.149188E+10 | 0.00 | 0.00 |
April | 0.185415E+10 | 0.239162E+10 | 0.273324E+10 | 0.109877E+10 | 0.163447E+10 | 0.00 | 0.00 |
May | 0.191607E+10 | 0.151433E+10 | 0.258823E+10 | 0.474064E+09 | 0.211417E+10 | 0.00 | 0.00 |
June | 0.230932E+10 | 0.795603E+09 | 0.230882E+10 | 0.421302E+09 | 0.188752E+10 | 0.00 | 0.00 |
July | 0.259561E+10 | 0.735746E+09 | 0.248390E+10 | 0.444346E+09 | 0.203955E+10 | 0.00 | 0.00 |
August | 0.306064E+10 | 0.861139E+09 | 0.316266E+10 | 0.132179E+10 | 0.184087E+10 | 0.00 | 0.00 |
September | 0.410627E+10 | 0.130923E+10 | 0.393868E+10 | 0.219785E+10 | 0.174083E+10 | 0.00 | 0.00 |
October | 0.498719E+10 | 0.280927E+10 | 0.486902E+10 | 0.345548E+10 | 0.141354E+10 | 0.00 | 0.00 |
November | 0.612633E+10 | 0.305788E+10 | 0.573904E+10 | 0.457514E+10 | 0.116390E+10 | 0.00 | 0.00 |
December | 0.593375E+10 | 0.367231E+10 | 0.566897E+10 | 0.458828E+10 | 0.108069E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.486886E+11 | 0.262157E+11 | 0.493695E+11 | 0.307848E+11 | 0.185847E+11 | 0.00 | 0.00 |
Minimum of Months | 0.185415E+10 | 0.735746E+09 | 0.230882E+10 | 0.421302E+09 | 0.108069E+10 | 0.00 | 0.00 |
Maximum of Months | 0.652245E+10 | 0.367231E+10 | 0.616776E+10 | 0.507371E+10 | 0.211417E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.654938E+10 | 0.316896E+10 | 0.616776E+10 | 0.507371E+10 | 0.109405E+10 | 0.00 | 0.00 |
February | 0.535569E+10 | 0.299064E+10 | 0.534616E+10 | 0.426289E+10 | 0.108326E+10 | 0.00 | 0.00 |
March | 0.396413E+10 | 0.266756E+10 | 0.436300E+10 | 0.287112E+10 | 0.149188E+10 | 0.00 | 0.00 |
April | 0.187766E+10 | 0.230424E+10 | 0.273324E+10 | 0.109877E+10 | 0.163447E+10 | 0.00 | 0.00 |
May | 0.193894E+10 | 0.144856E+10 | 0.258823E+10 | 0.474064E+09 | 0.211417E+10 | 0.00 | 0.00 |
June | 0.230190E+10 | 0.781138E+09 | 0.230882E+10 | 0.421302E+09 | 0.188752E+10 | 0.00 | 0.00 |
July | 0.258529E+10 | 0.728172E+09 | 0.248390E+10 | 0.444346E+09 | 0.203955E+10 | 0.00 | 0.00 |
August | 0.304893E+10 | 0.856310E+09 | 0.316266E+10 | 0.132179E+10 | 0.184087E+10 | 0.00 | 0.00 |
September | 0.409813E+10 | 0.129743E+10 | 0.393868E+10 | 0.219785E+10 | 0.174083E+10 | 0.00 | 0.00 |
October | 0.499497E+10 | 0.275038E+10 | 0.486902E+10 | 0.345548E+10 | 0.141354E+10 | 0.00 | 0.00 |
November | 0.614660E+10 | 0.297348E+10 | 0.573904E+10 | 0.457514E+10 | 0.116390E+10 | 0.00 | 0.00 |
December | 0.595243E+10 | 0.359309E+10 | 0.566897E+10 | 0.458828E+10 | 0.108069E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.488141E+11 | 0.255600E+11 | 0.493695E+11 | 0.307848E+11 | 0.185847E+11 | 0.00 | 0.00 |
Minimum of Months | 0.187766E+10 | 0.728172E+09 | 0.230882E+10 | 0.421302E+09 | 0.108069E+10 | 0.00 | 0.00 |
Maximum of Months | 0.654938E+10 | 0.359309E+10 | 0.616776E+10 | 0.507371E+10 | 0.211417E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132748E+10 | 0.639474E+09 | 0.126911E+10 | 0.104399E+10 | 0.225117E+09 | 0.00 | 0.00 |
February | 0.108451E+10 | 0.609810E+09 | 0.110005E+10 | 0.877153E+09 | 0.222897E+09 | 0.00 | 0.00 |
March | 0.806354E+09 | 0.542491E+09 | 0.897752E+09 | 0.590775E+09 | 0.306976E+09 | 0.00 | 0.00 |
April | 0.382508E+09 | 0.467881E+09 | 0.562404E+09 | 0.226087E+09 | 0.336317E+09 | 0.00 | 0.00 |
May | 0.400623E+09 | 0.284462E+09 | 0.532566E+09 | 97545612.91 | 0.435021E+09 | 0.00 | 0.00 |
June | 0.435948E+09 | 0.166107E+09 | 0.475073E+09 | 86689014.65 | 0.388384E+09 | 0.00 | 0.00 |
July | 0.488673E+09 | 0.156917E+09 | 0.511098E+09 | 91430603.58 | 0.419667E+09 | 0.00 | 0.00 |
August | 0.591974E+09 | 0.185604E+09 | 0.650763E+09 | 0.271978E+09 | 0.378785E+09 | 0.00 | 0.00 |
September | 0.816158E+09 | 0.273122E+09 | 0.810441E+09 | 0.452239E+09 | 0.358202E+09 | 0.00 | 0.00 |
October | 0.102069E+10 | 0.552714E+09 | 0.100187E+10 | 0.711016E+09 | 0.290856E+09 | 0.00 | 0.00 |
November | 0.124824E+10 | 0.597798E+09 | 0.118089E+10 | 0.941402E+09 | 0.239489E+09 | 0.00 | 0.00 |
December | 0.120281E+10 | 0.731876E+09 | 0.116647E+10 | 0.944106E+09 | 0.222368E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.980597E+10 | 0.520826E+10 | 0.101585E+11 | 0.633441E+10 | 0.382408E+10 | 0.00 | 0.00 |
Minimum of Months | 0.382508E+09 | 0.156917E+09 | 0.475073E+09 | 86689014.65 | 0.222368E+09 | 0.00 | 0.00 |
Maximum of Months | 0.132748E+10 | 0.731876E+09 | 0.126911E+10 | 0.104399E+10 | 0.435021E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 0.85 | -1.5 | -4.5 | 2.30 | -12.1 | 27.63 | 226.20 | 0.01 |
February | -0.2 | -2.7 | -6.1 | 3.74 | -13.6 | 32.55 | 253.27 | 0.01 |
March | 4.82 | 0.40 | -5.5 | 4.48 | -7.8 | 54.65 | 233.06 | 0.03 |
April | 6.08 | 2.31 | -2.0 | 5.23 | -4.9 | 81.86 | 179.11 | 0.05 |
May | 13.74 | 7.51 | 1.82 | 4.10 | 2.75 | 117.64 | 180.87 | 0.01 |
June | 22.16 | 12.44 | 5.10 | 4.19 | 9.76 | 95.26 | 290.95 | 0.00 |
July | 22.71 | 13.23 | 6.43 | 4.25 | 12.01 | 110.54 | 215.12 | 0.03 |
August | 21.74 | 12.78 | 6.20 | 3.81 | 10.76 | 77.72 | 272.61 | 0.02 |
September | 18.54 | 9.33 | 1.35 | 4.13 | 5.52 | 70.51 | 233.03 | 0.01 |
October | 7.12 | 2.51 | -2.7 | 3.54 | -5.8 | 44.60 | 216.74 | 0.01 |
November | 3.03 | 0.32 | -2.9 | 2.79 | -8.8 | 30.71 | 220.86 | 0.01 |
December | -1.0 | -4.5 | -9.5 | 4.43 | -15.4 | 27.45 | 194.75 | 0.01 |
Annual Sum or Average | 10.02 | 4.39 | -1.0 | 3.91 | -2.2 | 64.46 | 226.11 | 0.02 |
Minimum of Months | -1.0 | -4.5 | -9.5 | 2.30 | -15.4 | 27.45 | 179.11 | 0.00 |
Maximum of Months | 22.71 | 13.23 | 6.43 | 5.23 | 12.01 | 117.64 | 290.95 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.00 | 20-JAN-12:00 | 6.93 | -11.0 | 0.50 | 6.55 | 41.00 | 961.00 |
February | 20.00 | 18-FEB-12:00 | 7.71 | -5.0 | 3.60 | 6.35 | 56.00 | 998.00 |
March | 24.00 | 14-MAR-12:00 | 7.86 | -12.0 | 3.10 | 11.65 | 160.00 | 837.50 |
April | 22.00 | 19-APR-13:09 | 8.46 | -5.7 | 5.52 | 11.55 | 235.67 | 789.67 |
May | 29.00 | 17-MAY-12:00 | 11.89 | -3.0 | 5.10 | 18.99 | 432.50 | 162.00 |
June | 39.40 | 26-JUN-14:00 | 15.59 | -2.8 | 4.60 | 21.96 | 136.50 | 752.00 |
July | 37.00 | 16-JUL-12:00 | 14.86 | -3.0 | 3.10 | 26.65 | 319.50 | 109.50 |
August | 37.00 | 16-AUG-13:00 | 16.32 | 3.00 | 3.60 | 28.27 | 90.00 | 895.00 |
September | 32.70 | 09-SEP-12:00 | 13.01 | -3.9 | 3.00 | 16.30 | 270.50 | 562.00 |
October | 27.00 | 11-OCT-13:00 | 9.69 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 22.00 | 06-NOV-13:09 | 7.06 | -13.0 | 2.60 | 4.92 | 88.67 | 883.33 |
December | 22.00 | 01-DEC-13:00 | 7.90 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.00 | 6.93 | -13.0 | 0.50 | 4.92 | 41.00 | 109.50 | |
Maximum of Months | 39.40 | 16.32 | 3.00 | 5.52 | 28.27 | 432.50 | 998.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -19.0 | 05-JAN-18:00 | -19.0 | -19.0 | 1.50 | -37.1 | 0.00 | 0.00 |
February | -20.0 | 12-FEB-04:00 | -20.0 | -20.0 | 3.60 | -39.1 | 0.00 | 0.00 |
March | -15.6 | 19-MAR-06:00 | -15.6 | -15.6 | 10.80 | -25.3 | 24.00 | 0.00 |
April | -8.0 | 03-APR-02:00 | -8.0 | -8.0 | 3.10 | -22.2 | 0.00 | 0.00 |
May | -1.0 | 03-MAY-01:00 | -2.3 | -4.0 | 4.10 | -15.7 | 0.00 | 0.00 |
June | 6.60 | 09-JUN-03:00 | 3.44 | 0.00 | 3.60 | -6.9 | 0.00 | 0.00 |
July | 9.00 | 02-JUL-04:00 | 3.29 | -3.0 | 3.60 | -5.3 | 20.00 | 184.50 |
August | 11.00 | 12-AUG-22:00 | 7.21 | 4.00 | 4.10 | 5.13 | 0.00 | 0.00 |
September | -1.7 | 22-SEP-05:10 | -2.8 | -4.3 | 3.60 | -15.8 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.0 | -10.0 | 2.60 | -18.6 | 0.00 | 0.00 |
November | -15.0 | 29-NOV-20:00 | -15.0 | -15.0 | 3.10 | -33.5 | 0.00 | 0.00 |
December | -23.0 | 22-DEC-02:00 | -23.0 | -23.0 | 3.60 | -42.7 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -23.0 | -23.0 | -23.0 | 1.50 | -42.7 | 0.00 | 0.00 | |
Maximum of Months | 11.00 | 7.21 | 4.00 | 10.80 | 5.13 | 24.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 7.52 | 20-JAN-11:00 | 20.00 | -6.0 | 2.60 | 7.95 | 43.00 | 971.50 |
February | 7.95 | 18-FEB-14:00 | 19.00 | -3.0 | 3.60 | 5.94 | 151.00 | 410.00 |
March | 7.98 | 31-MAR-17:00 | 15.00 | 2.00 | 2.60 | 1.58 | 19.50 | 261.00 |
April | 12.48 | 28-APR-13:00 | 18.00 | 9.00 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 14.84 | 31-MAY-13:00 | 28.00 | 7.00 | 4.60 | 14.47 | 157.50 | 830.50 |
June | 19.63 | 18-JUN-11:00 | 29.40 | 15.50 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 19.73 | 30-JUL-13:00 | 29.00 | 16.00 | 3.60 | 18.99 | 217.50 | 412.00 |
August | 18.79 | 05-AUG-14:09 | 25.83 | 15.33 | 6.62 | 20.51 | 196.33 | 4.00 |
September | 14.93 | 01-SEP-11:00 | 24.40 | 9.40 | 3.00 | 10.69 | 193.50 | 684.00 |
October | 9.69 | 11-OCT-13:00 | 27.00 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 9.31 | 09-NOV-10:00 | 20.00 | 0.00 | 1.50 | 11.07 | 112.00 | 860.50 |
December | 7.90 | 01-DEC-13:00 | 22.00 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.52 | 15.00 | -9.0 | 1.50 | 1.58 | 19.50 | 4.00 | |
Maximum of Months | 19.73 | 29.40 | 16.00 | 9.80 | 20.51 | 335.00 | 971.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.00 | 28-JAN-10:00 | 5.00 | 5.00 | 1.00 | -6.2 | 207.00 | 309.00 |
February | 5.00 | 19-FEB-14:30 | 5.00 | 5.00 | 1.80 | -0.4 | 188.00 | 467.00 |
March | 7.00 | 17-MAR-14:00 | 8.00 | 7.39 | 8.20 | 1.16 | 121.50 | 3.00 |
April | 9.00 | 28-APR-13:00 | 18.00 | 12.48 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 11.00 | 21-MAY-21:10 | 12.83 | 11.72 | 2.68 | 6.78 | 0.00 | 0.00 |
June | 15.50 | 18-JUN-11:00 | 29.40 | 19.63 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 17.00 | 28-JUL-16:00 | 20.00 | 17.91 | 5.70 | 15.02 | 155.00 | 32.00 |
August | 18.00 | 04-AUG-01:00 | 18.00 | 18.00 | 2.60 | 8.74 | 0.00 | 0.00 |
September | 12.20 | 30-SEP-14:00 | 17.20 | 13.89 | 5.10 | 9.72 | 209.00 | 82.50 |
October | 6.00 | 01-OCT-19:00 | 9.00 | 7.28 | 3.10 | 3.69 | 0.00 | 0.00 |
November | 7.00 | 09-NOV-23:00 | 8.00 | 7.39 | 4.10 | 3.06 | 0.00 | 0.00 |
December | 1.00 | 30-DEC-14:00 | 7.00 | 4.05 | 9.80 | -1.2 | 101.00 | 91.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | 5.00 | 4.05 | 1.00 | -6.2 | 0.00 | 0.00 | |
Maximum of Months | 18.00 | 29.40 | 19.63 | 9.80 | 16.85 | 335.00 | 596.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 8.52 | 21.53 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 7.90 | 29.36 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 8.65 | 35.75 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 10.64 | 38.62 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 13.34 | 48.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 16.03 | 59.81 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.97 | 52.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.66 | 51.98 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.88 | 41.73 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.85 | 30.82 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 13.14 | 23.90 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 10.46 | 18.59 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 13.28 | 37.76 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 7.90 | 18.59 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.66 | 59.81 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.281940E+10 | -.239142E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -427979778.9 | 59.00 | 0.00 | 0.00 |
February | 0.259285E+10 | -.220458E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -388271753.9 | 58.99 | 0.00 | 0.00 |
March | 0.288608E+10 | -.246451E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -421571087.0 | 59.00 | 0.00 | 0.00 |
April | 0.265643E+10 | -.225100E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -405426780.7 | 59.00 | 0.00 | 0.00 |
May | 0.259961E+10 | -.220027E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -399335094.8 | 58.99 | 0.00 | 0.00 |
June | 0.240516E+10 | -.203119E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -373966455.6 | 58.99 | 0.00 | 0.00 |
July | 0.233129E+10 | -.194507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -386223503.1 | 58.99 | 0.00 | 0.00 |
August | 0.236061E+10 | -.197461E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -386000428.5 | 59.00 | 0.00 | 0.00 |
September | 0.229040E+10 | -.191465E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -375756410.3 | 58.99 | 0.00 | 0.00 |
October | 0.245232E+10 | -.204482E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -407501727.5 | 58.99 | 0.00 | 0.00 |
November | 0.250037E+10 | -.209312E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -407250786.8 | 58.99 | 0.00 | 0.00 |
December | 0.272998E+10 | -.230103E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -428946318.5 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.306245E+11 | -.258163E+11 | 8760.00 | -.480823E+10 | 58.99 | |||||
Minimum of Months | 0.229040E+10 | -.246451E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -428946318.5 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.288608E+10 | -.191465E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -373966455.6 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.92 | 0.58 | 27-JAN-11:09 | 141.83 | 3.33 | 0.00 | 0.00 | 1537.56 | 2.25 | 0.00 | 51.50 |
February | 245.50 | 0.93 | 0.58 | 28-FEB-11:30 | 171.97 | 4.04 | 0.00 | 0.17 | 144.37 | 2.65 | 0.00 | 0.00 |
March | 296.17 | 0.87 | 0.50 | 27-MAR-12:09 | 242.65 | 6.08 | 0.00 | 7.83 | 202.08 | 4.59 | 0.00 | 2.00 |
April | 296.67 | 0.76 | 0.50 | 03-APR-11:50 | 1589.06 | 8.52 | 0.00 | 77.33 | 3338.04 | 7.01 | 0.00 | 88.00 |
May | 415.33 | 0.77 | 0.50 | 02-MAY-10:20 | 369.54 | 9.97 | 0.00 | 104.00 | 308.51 | 8.33 | 0.00 | 64.17 |
June | 421.50 | 0.81 | 0.50 | 02-JUN-10:20 | 314.42 | 9.33 | 0.00 | 50.50 | 265.51 | 7.66 | 0.00 | 30.17 |
July | 430.33 | 0.79 | 0.50 | 02-JUL-11:09 | 424.30 | 9.72 | 0.00 | 91.67 | 421.18 | 8.11 | 0.00 | 53.00 |
August | 394.50 | 0.80 | 0.50 | 01-AUG-10:00 | 1726.88 | 8.06 | 0.00 | 82.50 | 2337.71 | 6.55 | 0.00 | 60.83 |
September | 354.00 | 0.84 | 0.50 | 01-SEP-12:30 | 282.01 | 6.90 | 0.00 | 33.83 | 231.75 | 5.34 | 0.00 | 14.33 |
October | 262.67 | 0.89 | 0.67 | 01-OCT-11:50 | 284.93 | 5.63 | 0.00 | 1.83 | 186.14 | 4.23 | 0.00 | 0.00 |
November | 257.67 | 0.91 | 0.67 | 01-NOV-11:20 | 1536.76 | 4.04 | 0.00 | 43.67 | 135.44 | 2.76 | 0.00 | 0.00 |
December | 251.17 | 0.96 | 0.75 | 31-DEC-12:30 | 142.52 | 3.84 | 0.00 | 0.00 | 118.26 | 2.57 | 0.00 | 0.00 |
Annual Sum or Average | 3902.00 | 0.84 | 610.20 | 7.07 | 0.00 | 493.33 | 781.59 | 5.59 | 0.00 | 364.00 | ||
Minimum of Months | 245.50 | 0.76 | 0.50 | 141.83 | 3.33 | 0.00 | 0.00 | 118.26 | 2.25 | 0.00 | 0.00 | |
Maximum of Months | 430.33 | 0.96 | 0.75 | 1726.88 | 9.97 | 0.00 | 104.00 | 3338.04 | 8.33 | 0.00 | 88.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.104170E+11 | 47522.11 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.108607E+11 | 47522.11 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.720890E+10 | 47522.11 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.503361E+10 | 47522.11 | 01-APR-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.424838E+09 | 47522.11 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 20066239.37 | 7933.21 | 22-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.267956E+10 | 47522.11 | 23-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.576191E+10 | 47522.11 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.124148E+11 | 47522.11 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.548214E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.124148E+11 | 47522.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.281870E+11 | 246936.73 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.278358E+11 | 246936.73 | 05-FEB-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.166180E+11 | 246936.73 | 19-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.113131E+11 | 246936.73 | 03-APR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.532683E+09 | 37836.81 | 01-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 69705647.76 | 27793.32 | 22-SEP-06:27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.892564E+10 | 206907.97 | 31-OCT-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.170164E+11 | 246936.73 | 30-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.368540E+11 | 246936.73 | 10-DEC-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.147352E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.368540E+11 | 246936.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.135183E+10 | 31258.65 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.210229E+10 | 31258.65 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.161081E+10 | 31258.65 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.128269E+10 | 31258.65 | 02-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 95150306.03 | 31258.65 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 2438400.59 | 6821.84 | 30-JUN-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 490606.38 | 1635.35 | 20-AUG-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 5592553.14 | 3337.66 | 03-SEP-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.758204E+09 | 31258.65 | 23-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.806802E+09 | 31258.65 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.260087E+10 | 31258.65 | 06-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.106172E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.260087E+10 | 31258.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.262529E+10 | 26406.10 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.354938E+10 | 26406.10 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.301697E+10 | 26406.10 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.253024E+10 | 26406.10 | 02-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.227040E+09 | 26406.10 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 23130221.27 | 8941.43 | 22-SEP-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143497E+10 | 26406.10 | 23-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168438E+10 | 26406.10 | 01-NOV-04:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.421996E+10 | 26406.10 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.193114E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.421996E+10 | 26406.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.820847E+10 | 38559.05 | 05-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.835999E+10 | 31549.32 | 11-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.607059E+10 | 29016.35 | 04-MAR-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.518051E+10 | 22632.67 | 02-APR-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.884561E+09 | 9319.14 | 02-MAY-11:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5015459.20 | 1091.79 | 02-JUN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 55344.15 | 63.83 | 19-JUL-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1140660.16 | 809.98 | 29-AUG-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.319329E+09 | 17444.94 | 21-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.431862E+10 | 27413.26 | 31-OCT-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.668028E+10 | 32750.89 | 29-NOV-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.102613E+11 | 44272.28 | 21-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.502899E+11 | |||||||
Minimum of Months | 55344.15 | 63.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.102613E+11 | 44272.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.146690E+09 | 0.146690E+09 | 4716.25 | 14-MAR-13:10 | 4716.25 | 0.00 |
April | 0.00 | 0.00 | 23132292.36 | 23132254.37 | 2414.50 | 20-APR-13:00 | 2414.50 | 0.00 |
May | 0.00 | 0.00 | 0.188581E+10 | 0.185561E+10 | 9844.12 | 31-MAY-15:00 | 9027.28 | 0.00 |
June | 0.00 | 0.00 | 0.125443E+11 | 0.117761E+11 | 35168.36 | 18-JUN-18:18 | 25439.94 | 0.00 |
July | 0.00 | 0.00 | 0.133289E+11 | 0.122667E+11 | 35502.68 | 23-JUL-21:04 | 21968.28 | 0.00 |
August | 0.00 | 0.00 | 0.124692E+11 | 0.116139E+11 | 36020.08 | 04-AUG-02:15 | 16728.96 | 0.00 |
September | 0.00 | 0.00 | 0.810287E+10 | 0.793557E+10 | 33781.56 | 02-SEP-21:41 | 27002.47 | 0.00 |
October | 0.00 | 0.00 | 0.583721E+09 | 0.583720E+09 | 9189.32 | 11-OCT-14:10 | 9189.32 | 0.00 |
November | 0.00 | 0.00 | 29319457.73 | 29319457.63 | 2379.69 | 07-NOV-15:10 | 2379.69 | 0.00 |
December | 0.00 | 0.00 | 155.27 | 155.27 | 0.24 | 02-DEC-15:00 | 0.24 | 0.00 |
Annual Sum or Average | 0.491139E+11 | 0.462308E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.133289E+11 | 0.122667E+11 | 36020.08 | 27002.47 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 90272998.58 | 90272998.58 | 10205.61 | 20-JAN-14:00 | 10205.61 | 0.00 |
February | 0.00 | 0.00 | 66109967.91 | 66109967.91 | 8667.93 | 18-FEB-13:50 | 8667.93 | 0.00 |
March | 0.00 | 0.00 | 0.241301E+10 | 0.241301E+10 | 74135.67 | 14-MAR-20:25 | 74135.67 | 0.00 |
April | 0.00 | 0.00 | 0.131958E+10 | 0.131951E+10 | 23382.28 | 20-APR-13:00 | 23382.28 | 0.00 |
May | 0.00 | 0.00 | 0.164855E+11 | 0.162353E+11 | 150396.55 | 31-MAY-20:20 | 125819.99 | 0.00 |
June | 0.00 | 0.00 | 0.713310E+11 | 0.670681E+11 | 160053.75 | 18-JUN-18:11 | 118521.91 | 0.00 |
July | 0.00 | 0.00 | 0.736971E+11 | 0.679357E+11 | 163825.21 | 30-JUL-20:55 | 79884.57 | 0.00 |
August | 0.00 | 0.00 | 0.690272E+11 | 0.646676E+11 | 164202.15 | 04-AUG-02:20 | 76482.40 | 0.00 |
September | 0.00 | 0.00 | 0.453263E+11 | 0.444967E+11 | 153912.66 | 02-SEP-21:56 | 124502.04 | 0.00 |
October | 0.00 | 0.00 | 0.569590E+10 | 0.569571E+10 | 54102.05 | 11-OCT-14:10 | 54102.05 | 0.00 |
November | 0.00 | 0.00 | 0.856481E+09 | 0.856481E+09 | 23204.87 | 07-NOV-15:10 | 23204.87 | 0.00 |
December | 0.00 | 0.00 | 0.172615E+09 | 0.172615E+09 | 14428.55 | 02-DEC-15:00 | 14428.55 | 0.00 |
Annual Sum or Average | 0.286481E+12 | 0.271017E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 66109967.91 | 66109967.91 | 8667.93 | 8667.93 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.736971E+11 | 0.679357E+11 | 164202.15 | 125819.99 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.301363E+09 | 0.301363E+09 | 8158.34 | 20-JAN-13:50 | 8158.34 | 0.00 |
February | 0.00 | 0.00 | 0.125968E+09 | 0.125968E+09 | 6974.39 | 18-FEB-14:00 | 6974.39 | 0.00 |
March | 0.00 | 0.00 | 0.802094E+09 | 0.802094E+09 | 10824.90 | 14-MAR-13:00 | 10824.90 | 0.00 |
April | 0.00 | 0.00 | 0.360085E+09 | 0.360032E+09 | 5823.40 | 20-APR-13:00 | 5823.40 | 0.00 |
May | 0.00 | 0.00 | 0.258202E+10 | 0.256442E+10 | 20802.93 | 31-MAY-20:15 | 17465.04 | 0.00 |
June | 0.00 | 0.00 | 0.106149E+11 | 0.101736E+11 | 22150.21 | 18-JUN-18:11 | 15809.25 | 0.00 |
July | 0.00 | 0.00 | 0.115398E+11 | 0.108478E+11 | 22652.23 | 29-JUL-21:20 | 12786.82 | 0.00 |
August | 0.00 | 0.00 | 0.114330E+11 | 0.109280E+11 | 22825.92 | 04-AUG-01:30 | 10649.34 | 0.00 |
September | 0.00 | 0.00 | 0.924288E+10 | 0.914694E+10 | 21216.27 | 02-SEP-22:21 | 16594.21 | 0.00 |
October | 0.00 | 0.00 | 0.216169E+10 | 0.216133E+10 | 20559.04 | 01-OCT-18:10 | 19093.16 | 0.00 |
November | 0.00 | 0.00 | 0.742276E+09 | 0.742273E+09 | 20559.04 | 05-NOV-18:10 | 20559.04 | 0.00 |
December | 0.00 | 0.00 | 0.377811E+09 | 0.377811E+09 | 8547.97 | 02-DEC-15:00 | 8547.97 | 0.00 |
Annual Sum or Average | 0.502839E+11 | 0.485317E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.125968E+09 | 0.125968E+09 | 5823.40 | 5823.40 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.115398E+11 | 0.109280E+11 | 22825.92 | 20559.04 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.178969E+09 | 0.178969E+09 | 5969.57 | 20-JAN-14:00 | 5969.57 | 0.00 |
February | 0.00 | 0.00 | 67924651.05 | 67924651.05 | 5023.07 | 18-FEB-14:00 | 5023.07 | 0.00 |
March | 0.00 | 0.00 | 0.489383E+09 | 0.489383E+09 | 8244.08 | 14-MAR-13:00 | 8244.08 | 0.00 |
April | 0.00 | 0.00 | 0.142306E+09 | 0.142305E+09 | 3694.73 | 20-APR-13:00 | 3694.73 | 0.00 |
May | 0.00 | 0.00 | 0.143649E+10 | 0.143126E+10 | 6675.09 | 17-MAY-13:30 | 6675.09 | 0.00 |
June | 0.00 | 0.00 | 0.759472E+10 | 0.730317E+10 | 17569.63 | 18-JUN-18:11 | 12546.16 | 0.00 |
July | 0.00 | 0.00 | 0.829152E+10 | 0.784104E+10 | 18011.50 | 29-JUL-21:45 | 10082.77 | 0.00 |
August | 0.00 | 0.00 | 0.841572E+10 | 0.807284E+10 | 17990.23 | 04-AUG-00:42 | 8838.67 | 0.00 |
September | 0.00 | 0.00 | 0.690519E+10 | 0.684024E+10 | 16826.75 | 02-SEP-21:49 | 13526.76 | 0.00 |
October | 0.00 | 0.00 | 0.155841E+10 | 0.155831E+10 | 16318.41 | 08-OCT-18:10 | 15867.76 | 0.00 |
November | 0.00 | 0.00 | 0.517561E+09 | 0.517560E+09 | 8399.81 | 07-NOV-14:00 | 8399.81 | 0.00 |
December | 0.00 | 0.00 | 0.221786E+09 | 0.221786E+09 | 6353.75 | 02-DEC-15:00 | 6353.75 | 0.00 |
Annual Sum or Average | 0.358200E+11 | 0.346648E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 67924651.05 | 67924651.05 | 3694.73 | 3694.73 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.841572E+10 | 0.807284E+10 | 18011.50 | 15867.76 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.408367E+10 | 0.57 | 2885.74 | 01-JAN-07:01 | 1.08 |
February | 0.390994E+10 | 0.61 | 2885.74 | 01-FEB-05:01 | 1.08 |
March | 0.379633E+10 | 0.53 | 2885.74 | 01-MAR-05:01 | 1.08 |
April | 0.371451E+10 | 0.54 | 2885.74 | 01-APR-04:02 | 1.08 |
May | 0.207193E+10 | 0.29 | 2885.74 | 01-MAY-04:01 | 1.08 |
June | 91716968.14 | 0.01 | 2885.74 | 01-JUN-07:07 | 1.07 |
July | 0.102143E+09 | 0.01 | 2885.74 | 02-JUL-07:06 | 1.08 |
August | 0.102907E+09 | 0.01 | 2885.74 | 01-AUG-07:06 | 1.07 |
September | 0.404798E+09 | 0.06 | 2885.74 | 01-SEP-07:06 | 1.07 |
October | 0.297083E+10 | 0.42 | 2885.74 | 01-OCT-07:03 | 1.08 |
November | 0.353230E+10 | 0.51 | 2885.74 | 01-NOV-00:10 | 1.08 |
December | 0.418406E+10 | 0.59 | 2885.74 | 01-DEC-05:01 | 1.08 |
Annual Sum or Average | 0.289651E+11 | 0.34 | |||
Minimum of Months | 91716968.14 | 0.01 | 2885.74 | 1.07 | |
Maximum of Months | 0.418406E+10 | 0.61 | 2885.74 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.176642E+10 | 0.47 | 2249.36 | 01-JAN-07:01 | 1.08 |
February | 0.164888E+10 | 0.49 | 2249.36 | 01-FEB-05:01 | 1.08 |
March | 0.169512E+10 | 0.45 | 2249.36 | 01-MAR-05:01 | 1.08 |
April | 0.157009E+10 | 0.44 | 2249.36 | 01-APR-04:02 | 1.08 |
May | 0.146893E+10 | 0.40 | 2249.36 | 01-MAY-04:01 | 1.08 |
June | 0.145956E+10 | 0.42 | 2249.36 | 04-JUN-20:04 | 1.08 |
July | 0.149279E+10 | 0.41 | 2249.36 | 02-JUL-20:18 | 1.08 |
August | 0.151645E+10 | 0.42 | 2249.36 | 02-AUG-21:31 | 1.07 |
September | 0.143580E+10 | 0.41 | 2249.36 | 02-SEP-21:41 | 1.07 |
October | 0.152407E+10 | 0.41 | 2249.36 | 23-OCT-04:01 | 1.08 |
November | 0.157102E+10 | 0.44 | 2249.36 | 01-NOV-04:01 | 1.08 |
December | 0.183451E+10 | 0.50 | 2249.36 | 01-DEC-05:01 | 1.08 |
Annual Sum or Average | 0.189837E+11 | 0.44 | |||
Minimum of Months | 0.143580E+10 | 0.40 | 2249.36 | 1.07 | |
Maximum of Months | 0.183451E+10 | 0.50 | 2249.36 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.112994E+11 | 0.65 | 15930.69 | 01-JAN-08:62 | 1.69 |
February | 0.103470E+11 | 0.66 | 15930.69 | 05-FEB-08:62 | 1.69 |
March | 0.110394E+11 | 0.65 | 15930.69 | 19-MAR-07:02 | 1.69 |
April | 0.104169E+11 | 0.64 | 15930.69 | 03-APR-05:02 | 1.69 |
May | 0.103852E+11 | 0.62 | 12342.32 | 10-MAY-21:01 | 1.50 |
June | 0.108581E+11 | 0.69 | 15930.69 | 05-JUN-23:51 | 1.68 |
July | 0.109980E+11 | 0.68 | 15930.69 | 01-JUL-00:10 | 1.69 |
August | 0.112978E+11 | 0.69 | 15930.69 | 01-AUG-20:15 | 1.69 |
September | 0.105237E+11 | 0.66 | 15930.69 | 02-SEP-21:56 | 1.68 |
October | 0.105735E+11 | 0.63 | 14381.26 | 31-OCT-05:02 | 1.62 |
November | 0.105000E+11 | 0.64 | 15930.69 | 30-NOV-06:01 | 1.70 |
December | 0.116637E+11 | 0.67 | 15930.69 | 10-DEC-08:62 | 1.69 |
Annual Sum or Average | 0.129903E+12 | 0.66 | |||
Minimum of Months | 0.103470E+11 | 0.62 | 12342.32 | 1.50 | |
Maximum of Months | 0.116637E+11 | 0.69 | 15930.69 | 1.70 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.235426E+10 | 0.69 | 1461.15 | 02-JAN-20:17 | 1.12 |
February | 0.214398E+10 | 0.71 | 1461.15 | 03-FEB-06:15 | 1.12 |
March | 0.240513E+10 | 0.71 | 1461.15 | 02-MAR-07:07 | 1.12 |
April | 0.230181E+10 | 0.70 | 1461.15 | 01-APR-07:20 | 1.12 |
May | 0.236862E+10 | 0.68 | 1461.15 | 03-MAY-11:40 | 1.12 |
June | 0.243070E+10 | 0.74 | 1461.15 | 05-JUN-07:40 | 1.11 |
July | 0.250359E+10 | 0.74 | 1461.15 | 05-JUL-11:50 | 1.11 |
August | 0.259027E+10 | 0.78 | 1461.15 | 01-AUG-10:30 | 1.12 |
September | 0.248977E+10 | 0.79 | 1461.15 | 02-SEP-07:45 | 1.11 |
October | 0.238924E+10 | 0.72 | 1461.15 | 05-OCT-10:10 | 1.12 |
November | 0.226879E+10 | 0.69 | 1461.15 | 02-NOV-14:00 | 1.12 |
December | 0.236869E+10 | 0.71 | 1461.15 | 01-DEC-15:15 | 1.12 |
Annual Sum or Average | 0.286149E+11 | 0.72 | |||
Minimum of Months | 0.214398E+10 | 0.68 | 1461.15 | 1.11 | |
Maximum of Months | 0.259027E+10 | 0.79 | 1461.15 | 1.12 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.187637E+10 | 0.70 | 1159.76 | 01-JAN-09:45 | 1.12 |
February | 0.171135E+10 | 0.72 | 1159.76 | 01-FEB-18:50 | 1.12 |
March | 0.191310E+10 | 0.71 | 1159.76 | 01-MAR-06:33 | 1.12 |
April | 0.183404E+10 | 0.70 | 1159.76 | 01-APR-06:35 | 1.12 |
May | 0.187836E+10 | 0.68 | 1159.76 | 01-MAY-19:40 | 1.12 |
June | 0.188233E+10 | 0.71 | 1159.76 | 02-JUN-10:50 | 1.11 |
July | 0.192879E+10 | 0.71 | 1159.76 | 01-JUL-05:50 | 1.12 |
August | 0.198918E+10 | 0.73 | 1159.76 | 01-AUG-11:35 | 1.12 |
September | 0.192587E+10 | 0.74 | 1159.76 | 01-SEP-09:50 | 1.11 |
October | 0.188692E+10 | 0.70 | 1159.76 | 03-OCT-14:30 | 1.11 |
November | 0.180323E+10 | 0.69 | 1159.76 | 03-NOV-06:17 | 1.12 |
December | 0.189127E+10 | 0.72 | 1159.76 | 01-DEC-08:63 | 1.12 |
Annual Sum or Average | 0.225208E+11 | 0.71 | |||
Minimum of Months | 0.171135E+10 | 0.68 | 1159.76 | 1.11 | |
Maximum of Months | 0.198918E+10 | 0.74 | 1159.76 | 1.12 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.87 | 0.00 |
February | 1.48 | 0.00 |
March | 1.36 | 0.00 |
April | 0.64 | 0.00 |
May | 0.00 | 0.00 |
June | 0.35 | 0.00 |
July | 0.65 | 0.00 |
August | 0.61 | 0.00 |
September | 0.48 | 0.00 |
October | 0.36 | 0.00 |
November | 0.21 | 0.00 |
December | 2.00 | 0.00 |
Annual Sum or Average | 9.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.53 | 21.76 |
April | 0.67 | 25.84 |
May | 1.78 | 8.48 |
June | 3.88 | 0.00 |
July | 4.78 | 0.00 |
August | 4.10 | 0.00 |
September | 3.43 | 2.19 |
October | 1.52 | 25.84 |
November | 0.49 | 25.84 |
December | 0.11 | 0.00 |
Annual Sum or Average | 21.29 | 4.85 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 4.78 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.41 | 1.82 |
February | 0.41 | 0.75 |
March | 0.44 | 0.69 |
April | 0.24 | 1.60 |
May | 1.17 | 0.12 |
June | 4.90 | 0.00 |
July | 7.44 | 0.00 |
August | 8.60 | 0.00 |
September | 7.90 | 0.02 |
October | 1.12 | 1.01 |
November | 0.52 | 1.24 |
December | 0.72 | 0.47 |
Annual Sum or Average | 33.86 | 0.12 |
Minimum of Months | 0.24 | 0.00 |
Maximum of Months | 8.60 | 1.82 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.10 | 0.00 |
February | 0.70 | 0.29 |
March | 0.70 | 0.00 |
April | 0.61 | 0.00 |
May | 0.06 | 2.44 |
June | 2.02 | 0.00 |
July | 2.86 | 0.00 |
August | 4.73 | 0.00 |
September | 5.35 | 0.00 |
October | 1.14 | 1.10 |
November | 0.12 | 2.44 |
December | 0.72 | 0.00 |
Annual Sum or Average | 19.11 | 0.10 |
Minimum of Months | 0.06 | 0.00 |
Maximum of Months | 5.35 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 49.60 | 0.00 |
February | 50.55 | 0.00 |
March | 69.71 | 0.00 |
April | 59.07 | 0.00 |
May | 56.42 | 0.00 |
June | 5.22 | 0.00 |
July | 6.97 | 0.00 |
August | 7.89 | 0.00 |
September | 20.06 | 0.00 |
October | 47.18 | 0.00 |
November | 42.63 | 0.00 |
December | 62.76 | 0.00 |
Annual Sum or Average | 478.06 | 0.00 |
Minimum of Months | 5.22 | 0.00 |
Maximum of Months | 69.71 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.176642E+10 | 0.130213E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.164888E+10 | 0.135758E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.173507E+10 | 0.901112E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.157649E+10 | 0.629201E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.197795E+10 | 0.531048E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.481211E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.503557E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.479459E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.356225E+10 | 25082799.21 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.167921E+10 | 0.334945E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.157912E+10 | 0.720238E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.183451E+10 | 0.155186E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.320022E+11 | 0.685268E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.157649E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.503557E+10 | 0.155186E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.113270E+11 | 0.352337E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.103672E+11 | 0.347948E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.117322E+11 | 0.207725E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.108097E+11 | 0.141413E+11 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.151261E+11 | 0.665854E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.314963E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.322698E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.310268E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.234509E+11 | 87132059.70 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.122138E+11 | 0.111571E+11 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.107555E+11 | 0.212705E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.117165E+11 | 0.460675E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.212292E+12 | 0.184190E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.103672E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.322698E+11 | 0.460675E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.242471E+10 | 0.168978E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.217383E+10 | 0.262786E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.259006E+10 | 0.201351E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.238961E+10 | 0.160337E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.298830E+10 | 0.118938E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.504419E+10 | 3048000.73 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.531574E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.533314E+10 | 613257.97 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.463516E+10 | 6990691.43 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.287705E+10 | 0.947755E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.243552E+10 | 0.100850E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.245708E+10 | 0.325109E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.406644E+11 | 0.132715E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.217383E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.533314E+10 | 0.325109E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.191738E+10 | 0.328162E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.172700E+10 | 0.443673E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.202286E+10 | 0.377122E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.186850E+10 | 0.316280E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.222199E+10 | 0.283800E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.372770E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.392020E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.397069E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.349409E+10 | 28912776.58 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.222898E+10 | 0.179371E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.191630E+10 | 0.210548E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.194224E+10 | 0.527496E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.309579E+11 | 0.241392E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.172700E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.397069E+10 | 0.527496E+10 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.176642E+10 | 0.00 | 0.104170E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.164888E+10 | 0.00 | 0.108607E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.169512E+10 | 0.146690E+09 | 0.720890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157009E+10 | 23132292.36 | 0.503361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.146893E+10 | 0.188581E+10 | 0.424838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145956E+10 | 0.123865E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.149279E+10 | 0.131054E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151645E+10 | 0.122646E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143580E+10 | 0.801608E+10 | 20066239.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152407E+10 | 0.583721E+09 | 0.267956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.157102E+10 | 29319457.73 | 0.576191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.183451E+10 | 155.27 | 0.124148E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189837E+11 | 0.484413E+11 | 0.548214E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.143580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.183451E+10 | 0.131054E+11 | 0.124148E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.112994E+11 | 90272998.58 | 0.281870E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.103470E+11 | 66109967.91 | 0.278358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.110394E+11 | 0.241301E+10 | 0.166180E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104169E+11 | 0.131958E+10 | 0.113131E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.103852E+11 | 0.163074E+11 | 0.532683E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.108581E+11 | 0.695101E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.109980E+11 | 0.712269E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.112978E+11 | 0.667252E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.105237E+11 | 0.441360E+11 | 69705647.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.105735E+11 | 0.569590E+10 | 0.892564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.105000E+11 | 0.856481E+09 | 0.170164E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116637E+11 | 0.172615E+09 | 0.368540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.129903E+12 | 0.278520E+12 | 0.147352E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.103470E+11 | 66109967.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.116637E+11 | 0.712269E+11 | 0.368540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.235426E+10 | 0.301363E+09 | 0.135183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.214398E+10 | 0.125968E+09 | 0.210229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.240513E+10 | 0.802094E+09 | 0.161081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.230181E+10 | 0.360085E+09 | 0.128269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.236862E+10 | 0.258202E+10 | 95150306.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.243070E+10 | 0.106149E+11 | 2438400.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.250359E+10 | 0.115398E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.259027E+10 | 0.114330E+11 | 490606.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.248977E+10 | 0.924288E+10 | 5592553.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.238924E+10 | 0.216169E+10 | 0.758204E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.226879E+10 | 0.742276E+09 | 0.806802E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.236869E+10 | 0.377811E+09 | 0.260087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.286149E+11 | 0.502839E+11 | 0.106172E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.214398E+10 | 0.125968E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.259027E+10 | 0.115398E+11 | 0.260087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.187637E+10 | 0.178969E+09 | 0.262529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.171135E+10 | 67924651.05 | 0.354938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.191310E+10 | 0.489383E+09 | 0.301697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.183404E+10 | 0.142306E+09 | 0.253024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.187836E+10 | 0.143649E+10 | 0.227040E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.188233E+10 | 0.759472E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.192879E+10 | 0.829152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.198918E+10 | 0.841572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.192587E+10 | 0.690519E+10 | 23130221.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188692E+10 | 0.155841E+10 | 0.143497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.180323E+10 | 0.517561E+09 | 0.168438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.189127E+10 | 0.221786E+09 | 0.421996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.225208E+11 | 0.358200E+11 | 0.193114E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.171135E+10 | 67924651.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.198918E+10 | 0.841572E+10 | 0.421996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.176642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130213E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.164888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135758E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.169512E+10 | 0.00 | 0.00 | 0.00 | 39952708.71 | 0.00 | 0.901112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157009E+10 | 0.00 | 0.00 | 0.00 | 6406455.18 | 0.00 | 0.629201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.146893E+10 | 0.00 | 0.00 | 0.00 | 0.509022E+09 | 0.00 | 0.531048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145956E+10 | 0.00 | 0.00 | 0.00 | 0.335254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.149279E+10 | 0.00 | 0.00 | 0.00 | 0.354278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151645E+10 | 0.00 | 0.00 | 0.00 | 0.327814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143580E+10 | 0.00 | 0.00 | 0.00 | 0.212645E+10 | 0.00 | 25082799.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152407E+10 | 0.00 | 0.00 | 0.00 | 0.155146E+09 | 0.00 | 0.334945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.157102E+10 | 0.00 | 0.00 | 0.00 | 8098142.07 | 0.00 | 0.720238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.183451E+10 | 0.00 | 0.00 | 0.00 | 44.54 | 0.00 | 0.155186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189837E+11 | 0.00 | 0.00 | 0.00 | 0.130185E+11 | 0.00 | 0.685268E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.143580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.183451E+10 | 0.00 | 0.00 | 0.00 | 0.354278E+10 | 0.00 | 0.155186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.112994E+11 | 0.00 | 0.00 | 0.00 | 27544224.43 | 0.00 | 0.352337E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.103470E+11 | 0.00 | 0.00 | 0.00 | 20265931.96 | 0.00 | 0.347948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.110394E+11 | 0.00 | 0.00 | 0.00 | 0.692755E+09 | 0.00 | 0.207725E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104169E+11 | 0.00 | 0.00 | 0.00 | 0.392821E+09 | 0.00 | 0.141413E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.103852E+11 | 0.00 | 0.00 | 0.00 | 0.474088E+10 | 0.00 | 0.665854E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.108581E+11 | 0.00 | 0.00 | 0.00 | 0.206382E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.109980E+11 | 0.00 | 0.00 | 0.00 | 0.212718E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.112978E+11 | 0.00 | 0.00 | 0.00 | 0.197290E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.105237E+11 | 0.00 | 0.00 | 0.00 | 0.129272E+11 | 0.00 | 87132059.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.105735E+11 | 0.00 | 0.00 | 0.00 | 0.164030E+10 | 0.00 | 0.111571E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.105000E+11 | 0.00 | 0.00 | 0.00 | 0.255509E+09 | 0.00 | 0.212705E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116637E+11 | 0.00 | 0.00 | 0.00 | 52844699.37 | 0.00 | 0.460675E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.129903E+12 | 0.00 | 0.00 | 0.00 | 0.823891E+11 | 0.00 | 0.184190E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.103470E+11 | 0.00 | 0.00 | 0.00 | 20265931.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.116637E+11 | 0.00 | 0.00 | 0.00 | 0.212718E+11 | 0.00 | 0.460675E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.235426E+10 | 0.00 | 0.00 | 0.00 | 70450292.44 | 0.00 | 0.168978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.214398E+10 | 0.00 | 0.00 | 0.00 | 29848870.64 | 0.00 | 0.262786E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.240513E+10 | 0.00 | 0.00 | 0.00 | 0.184929E+09 | 0.00 | 0.201351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.230181E+10 | 0.00 | 0.00 | 0.00 | 87805764.66 | 0.00 | 0.160337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.236862E+10 | 0.00 | 0.00 | 0.00 | 0.619681E+09 | 0.00 | 0.118938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.243070E+10 | 0.00 | 0.00 | 0.00 | 0.261349E+10 | 0.00 | 3048000.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.250359E+10 | 0.00 | 0.00 | 0.00 | 0.281215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.259027E+10 | 0.00 | 0.00 | 0.00 | 0.274287E+10 | 0.00 | 613257.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.248977E+10 | 0.00 | 0.00 | 0.00 | 0.214538E+10 | 0.00 | 6990691.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.238924E+10 | 0.00 | 0.00 | 0.00 | 0.487817E+09 | 0.00 | 0.947755E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.226879E+10 | 0.00 | 0.00 | 0.00 | 0.166731E+09 | 0.00 | 0.100850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.236869E+10 | 0.00 | 0.00 | 0.00 | 88383511.55 | 0.00 | 0.325109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.286149E+11 | 0.00 | 0.00 | 0.00 | 0.120495E+11 | 0.00 | 0.132715E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.214398E+10 | 0.00 | 0.00 | 0.00 | 29848870.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.259027E+10 | 0.00 | 0.00 | 0.00 | 0.281215E+10 | 0.00 | 0.325109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.187637E+10 | 0.00 | 0.00 | 0.00 | 41009289.18 | 0.00 | 0.328162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.171135E+10 | 0.00 | 0.00 | 0.00 | 15651655.09 | 0.00 | 0.443673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.191310E+10 | 0.00 | 0.00 | 0.00 | 0.109758E+09 | 0.00 | 0.377122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.183404E+10 | 0.00 | 0.00 | 0.00 | 34462262.41 | 0.00 | 0.316280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.187836E+10 | 0.00 | 0.00 | 0.00 | 0.343636E+09 | 0.00 | 0.283800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.188233E+10 | 0.00 | 0.00 | 0.00 | 0.184537E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.192879E+10 | 0.00 | 0.00 | 0.00 | 0.199141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.198918E+10 | 0.00 | 0.00 | 0.00 | 0.198150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.192587E+10 | 0.00 | 0.00 | 0.00 | 0.156822E+10 | 0.00 | 28912776.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188692E+10 | 0.00 | 0.00 | 0.00 | 0.342062E+09 | 0.00 | 0.179371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.180323E+10 | 0.00 | 0.00 | 0.00 | 0.113073E+09 | 0.00 | 0.210548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.189127E+10 | 0.00 | 0.00 | 0.00 | 50968536.42 | 0.00 | 0.527496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.225208E+11 | 0.00 | 0.00 | 0.00 | 0.843712E+10 | 0.00 | 0.241392E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.171135E+10 | 0.00 | 0.00 | 0.00 | 15651655.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.198918E+10 | 0.00 | 0.00 | 0.00 | 0.199141E+10 | 0.00 | 0.527496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.231493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538531E+10 | 0.00 | 0.00 | 0.20 |
February | 0.178487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540035E+10 | 0.00 | 0.00 | 0.20 |
March | 0.262278E+10 | 0.00 | 0.00 | 807163.92 | 0.00 | 0.350616E+10 | 0.771453E+09 | 0.00 | 0.25 |
April | 0.295893E+10 | 0.00 | 0.00 | 709208.58 | 0.00 | 0.240708E+10 | 0.833279E+09 | 0.00 | 0.24 |
May | 0.155256E+10 | 20829.64 | 0.00 | 6425973.90 | 0.00 | 0.107955E+09 | 0.370765E+10 | 0.00 | 0.41 |
June | 79915809.06 | 0.320206E+09 | 0.00 | 13715548.70 | 0.00 | 0.00 | 0.205929E+10 | 0.00 | 0.43 |
July | 59738643.47 | 0.491969E+09 | 0.00 | 12011203.26 | 0.00 | 0.00 | 0.168361E+10 | 0.00 | 0.42 |
August | 83741514.96 | 0.265310E+09 | 0.00 | 18237010.60 | 0.00 | 0.00 | 0.279159E+10 | 0.00 | 0.46 |
September | 0.489311E+09 | 19531582.41 | 0.00 | 17459397.89 | 0.00 | 2119132.74 | 0.361152E+10 | 0.00 | 0.49 |
October | 0.290115E+10 | 0.00 | 0.00 | 3760450.34 | 0.00 | 0.153921E+10 | 0.273457E+10 | 0.00 | 0.32 |
November | 0.345614E+10 | 0.00 | 0.00 | 589231.75 | 0.00 | 0.307255E+10 | 0.510318E+09 | 0.00 | 0.23 |
December | 0.221864E+10 | 0.00 | 0.00 | 675.65 | 0.00 | 0.600725E+10 | 9995540.00 | 0.00 | 0.20 |
Annual Sum or Average | 0.205227E+11 | 0.109704E+10 | 0.00 | 73715864.60 | 0.00 | 0.274280E+11 | 0.187133E+11 | 0.00 | 0.32 |
Minimum of Months | 59738643.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.20 |
Maximum of Months | 0.345614E+10 | 0.491969E+09 | 0.00 | 18237010.60 | 0.00 | 0.600725E+10 | 0.370765E+10 | 0.00 | 0.49 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.443496E+11 | 0.00 | 0.00 | 2870203.67 | 0.00 | 0.119209E+11 | 0.317570E+10 | 0.00 | 0.41 |
February | 0.406843E+11 | 0.00 | 0.00 | 2035062.88 | 0.00 | 0.128419E+11 | 0.250786E+10 | 0.00 | 0.40 |
March | 0.366515E+11 | 0.00 | 0.00 | 15659076.53 | 0.00 | 0.649644E+10 | 0.107146E+11 | 0.00 | 0.48 |
April | 0.334094E+11 | 0.00 | 0.00 | 15143520.57 | 0.00 | 0.377905E+10 | 0.112719E+11 | 0.00 | 0.48 |
May | 0.947322E+10 | 10655149.76 | 0.00 | 57332423.97 | 0.00 | 0.204918E+09 | 0.261629E+11 | 0.00 | 0.64 |
June | 0.329411E+09 | 0.454425E+10 | 0.00 | 65451262.71 | 0.00 | 0.00 | 0.110533E+11 | 0.00 | 0.65 |
July | 0.211134E+09 | 0.565339E+10 | 0.00 | 55552798.10 | 0.00 | 0.00 | 0.864968E+10 | 0.00 | 0.63 |
August | 0.537455E+09 | 0.348200E+10 | 0.00 | 78423205.22 | 0.00 | 0.00 | 0.140893E+11 | 0.00 | 0.67 |
September | 0.354970E+10 | 0.732930E+09 | 0.00 | 81534221.93 | 0.00 | 0.00 | 0.189719E+11 | 0.00 | 0.69 |
October | 0.285461E+11 | 0.00 | 0.00 | 32978078.39 | 0.00 | 0.219696E+10 | 0.200394E+11 | 0.00 | 0.53 |
November | 0.417977E+11 | 0.00 | 0.00 | 8223295.23 | 0.00 | 0.490947E+10 | 0.660342E+10 | 0.00 | 0.43 |
December | 0.434760E+11 | 0.00 | 0.00 | 2000833.36 | 0.00 | 0.189145E+11 | 0.217662E+10 | 0.00 | 0.41 |
Annual Sum or Average | 0.283016E+12 | 0.144232E+11 | 0.00 | 0.417204E+09 | 0.00 | 0.612642E+11 | 0.135417E+12 | 0.00 | 0.54 |
Minimum of Months | 0.211134E+09 | 0.00 | 0.00 | 2000833.36 | 0.00 | 0.00 | 0.217662E+10 | 0.00 | 0.40 |
Maximum of Months | 0.443496E+11 | 0.565339E+10 | 0.00 | 81534221.93 | 0.00 | 0.189145E+11 | 0.261629E+11 | 0.00 | 0.69 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.268954E+10 | 0.00 | 0.00 | 6573620.23 | 0.00 | 0.582247E+09 | 0.451838E+10 | 0.00 | 0.65 |
February | 0.231239E+10 | 0.00 | 0.00 | 4839369.23 | 0.00 | 0.111096E+10 | 0.357463E+10 | 0.00 | 0.60 |
March | 0.214851E+10 | 0.00 | 0.00 | 6880431.37 | 0.00 | 0.855240E+09 | 0.390913E+10 | 0.00 | 0.80 |
April | 0.212518E+10 | 0.00 | 0.00 | 4853874.01 | 0.00 | 0.726788E+09 | 0.309372E+10 | 0.00 | 0.77 |
May | 0.498133E+09 | 1679885.38 | 0.00 | 10200715.56 | 0.00 | 46609396.65 | 0.477199E+10 | 0.00 | 1.19 |
June | 36176241.26 | 0.487355E+09 | 0.00 | 8055578.46 | 0.00 | 0.00 | 0.191119E+10 | 0.00 | 1.06 |
July | 26193387.16 | 0.649543E+09 | 0.00 | 6964568.77 | 0.00 | 0.00 | 0.164632E+10 | 0.00 | 1.04 |
August | 20440228.42 | 0.399472E+09 | 0.00 | 12291861.60 | 0.00 | 0.00 | 0.274049E+10 | 0.00 | 1.19 |
September | 0.112729E+09 | 77277105.66 | 0.00 | 17006548.45 | 0.00 | 0.00 | 0.403371E+10 | 0.00 | 1.38 |
October | 0.157050E+10 | 0.00 | 0.00 | 14565013.70 | 0.00 | 0.394322E+09 | 0.627749E+10 | 0.00 | 1.11 |
November | 0.206243E+10 | 0.00 | 0.00 | 9731817.05 | 0.00 | 0.368887E+09 | 0.547237E+10 | 0.00 | 0.81 |
December | 0.293960E+10 | 0.00 | 0.00 | 5773628.17 | 0.00 | 0.132599E+10 | 0.370645E+10 | 0.00 | 0.65 |
Annual Sum or Average | 0.165418E+11 | 0.161533E+10 | 0.00 | 0.107737E+09 | 0.00 | 0.541105E+10 | 0.456559E+11 | 0.00 | 0.94 |
Minimum of Months | 20440228.42 | 0.00 | 0.00 | 4839369.23 | 0.00 | 0.00 | 0.164632E+10 | 0.00 | 0.60 |
Maximum of Months | 0.293960E+10 | 0.649543E+09 | 0.00 | 17006548.45 | 0.00 | 0.132599E+10 | 0.627749E+10 | 0.00 | 1.38 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.290107E+10 | 0.00 | 0.00 | 2646711.20 | 0.00 | 0.155597E+10 | 0.197303E+10 | 0.00 | 0.51 |
February | 0.252833E+10 | 0.00 | 0.00 | 1872828.00 | 0.00 | 0.185893E+10 | 0.153469E+10 | 0.00 | 0.49 |
March | 0.204747E+10 | 0.00 | 0.00 | 3097517.89 | 0.00 | 0.175401E+10 | 0.187512E+10 | 0.00 | 0.62 |
April | 0.182092E+10 | 0.00 | 0.00 | 1593249.32 | 0.00 | 0.160812E+10 | 0.132332E+10 | 0.00 | 0.57 |
May | 0.976780E+09 | 1206615.03 | 0.00 | 4271783.25 | 0.00 | 80510581.54 | 0.255382E+10 | 0.00 | 0.82 |
June | 0.116334E+09 | 0.442485E+09 | 0.00 | 4862708.62 | 0.00 | 0.00 | 0.120216E+10 | 0.00 | 0.81 |
July | 73751876.14 | 0.555601E+09 | 0.00 | 4452654.90 | 110497.80 | 0.00 | 0.104161E+10 | 0.00 | 0.79 |
August | 90386882.80 | 0.348430E+09 | 0.00 | 8087459.47 | 0.00 | 0.00 | 0.180408E+10 | 0.00 | 0.90 |
September | 0.286324E+09 | 75282888.07 | 0.00 | 11359078.05 | 0.00 | 13704944.71 | 0.264639E+10 | 0.00 | 1.04 |
October | 0.148659E+10 | 0.00 | 0.00 | 8669270.04 | 0.00 | 0.989034E+09 | 0.389082E+10 | 0.00 | 0.83 |
November | 0.261766E+10 | 0.00 | 0.00 | 4962147.97 | 0.00 | 0.873957E+09 | 0.280428E+10 | 0.00 | 0.62 |
December | 0.276553E+10 | 0.00 | 0.00 | 2531145.66 | 0.00 | 0.238707E+10 | 0.170375E+10 | 0.00 | 0.53 |
Annual Sum or Average | 0.177111E+11 | 0.142301E+10 | 0.00 | 58406554.37 | 110497.80 | 0.111213E+11 | 0.243531E+11 | 0.00 | 0.71 |
Minimum of Months | 73751876.14 | 0.00 | 0.00 | 1593249.32 | 0.00 | 0.00 | 0.104161E+10 | 0.00 | 0.49 |
Maximum of Months | 0.290107E+10 | 0.555601E+09 | 0.00 | 11359078.05 | 110497.80 | 0.238707E+10 | 0.389082E+10 | 0.00 | 1.04 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:11:32
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |