Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1978.30 | 862.38 | 862.38 |
Net Site Energy | 1978.30 | 862.38 | 862.38 |
Total Source Energy | 5590.93 | 2437.20 | 2437.20 |
Net Source Energy | 5590.93 | 2437.20 | 2437.20 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 230.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 419.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 492.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 115.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 432.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 93.27 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1654.56 | 323.74 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 230.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 419.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 492.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 115.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 432.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 93.27 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 264.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 371.50 | 141.13 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 721.26 | 141.13 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 264.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 371.50 | 141.13 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 721.26 | 141.13 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1654.560 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1654.560 | 100.00 |
Total On-Site and Utility Electric Sources | 1654.560 | 100.00 |
Total Electricity End Uses | 1654.560 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1088.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2004
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Latitude [deg] | 33.63 |
Longitude [deg] | -84.4 |
Elevation [m] | 308.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 8.56 |
Skylight-Roof Ratio [%] | 0.37 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 9.0309 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 18.2986 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.2986 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 18.2986 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 13.9931 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.7414 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.7414 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 08-JUL-14:50 | 12-FEB-08:09 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 277959.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 74790.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20936.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 141062.85 | 279821.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 277959.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 74790.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 20936.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 249.83 | 0.00 | 0.00 | 0.00 |
Cooling | 1328.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1558.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 364.62 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1370.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 101.11 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 5239.99 | 350.93 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 108.91 | 0.00 | 0.00 | 0.00 |
Cooling | 578.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 679.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 158.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 597.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 44.07 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2284.22 | 152.98 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 108.91 | 0.00 | 0.00 | 0.00 |
Cooling | 578.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 679.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 158.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 597.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 44.07 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2284.22 | 152.98 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 2.10 |
CORE_RETAIL DIRECT AIR | 8.65 |
POINT_OF_SALE DIRECT AIR | 1.26 |
FRONT_RETAIL DIRECT AIR | 1.05 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 2.73 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 2.73 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 61349.89 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 55768.36 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 270401.33 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 35341.28 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 30556.99 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 2.10 | 2.10 | 2.10 | 2.10 | 2.12 | 2.12 | 1.00 | 0.988854 | 2.12 |
PSZ-AC:2 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 1.00 | 1.00 | 8.65 |
PSZ-AC:3 | 1.26 | 1.26 | 1.26 | 1.26 | 1.26 | 1.26 | 1.00 | 1.00 | 1.26 |
PSZ-AC:4 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.00 | 1.00 | 1.05 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 2.12 | 0.289458 |
PSZ-AC:2_OA_CONTROLLER | 8.65 | 2.44 |
PSZ-AC:3_OA_CONTROLLER | 1.26 | 0.229820 |
PSZ-AC:4_OA_CONTROLLER | 1.05 | 0.229820 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 2.12 | 2.12 | 2.12 | 2.12 | 43317.84 | 55768.36 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 8.65 | 8.65 | 8.65 | 8.65 | 204151.01 | 270401.33 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.26 | 1.26 | 1.26 | 1.26 | 26511.47 | 35341.28 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 23086.13 | 30556.99 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 2.12 | 1.06 | 2.12 | 40605.71 | 43317.84 | 21658.92 | 43317.84 | 0.728660 | 0.728660 | 0.728660 | 0.728660 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 8.65 | 4.32 | 8.65 | 193564.77 | 204151.01 | 102075.51 | 204151.01 | 0.688763 | 0.688760 | 0.688760 | 0.688760 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.26 | 0.630535 | 1.26 | 24910.66 | 26511.47 | 13255.74 | 26511.47 | 0.720493 | 0.720490 | 0.720490 | 0.720490 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 1.05 | 0.522940 | 1.05 | 21778.04 | 23086.13 | 11543.07 | 23086.13 | 0.706716 | 0.706720 | 0.706720 | 0.706720 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.12 | 2318.85 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 8.65 | 15987.84 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.26 | 1437.76 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.05 | 1192.42 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 11.90 | 7.70 | 4.00 | 7.90 | 13.80 | 17.20 | 20.80 | 24.80 | 26.10 | 26.50 | 22.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 | 33.63 | -84.43 | -5.00 | 308.00 | 97679 | 1.1610 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.60 | 22.50 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 65 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 6.69 | 10 | 14 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 9.031 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.101 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 18.299 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.529 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 18.299 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 39.819 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 18.299 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 21.529 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 13.993 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13.993 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 3430.757 | 9.031 | 55.928 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3430.757 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 29286.673 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 29286.673 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2759.619 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2759.619 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2759.619 | 18.299 | 113.324 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2759.619 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 167.917 | 13.993 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 167.917 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 2.841 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.3762 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.9837 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3520 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.599 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8493 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.9750000 | 3.9750000 | 3.9750000 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 2.8409091 | 2.8409091 | 2.8409091 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61039648E-06 | 0.16815647E-08 | -0.37447326E-05 | 0.10149002E-16 |
21 | 2 | 0.76989337 | 0.22941655E-02 | 1.0458372 | -0.71793422E-06 |
22 | 1 | -21.843031 | 0.15409339 | -6.3407615 | 0.20050303 |
23 | 0 | 21.373924 | 0.14439780 | 5.5957134 | |
24 | 9 | 0.31844121E-15 | 0.33891907E-16 | -0.14717764E-09 | -0.34085343E-17 |
25 | 8 | 0.21517510E-07 | 0.13210865E-12 | 0.37403321E-03 | -0.24466149E-09 |
26 | 7 | -0.12129356E-01 | 0.68855956E-08 | -0.22924263E-01 | 0.13791520E-03 |
27 | 6 | 0.40230169 | 0.24029480E-05 | 0.46949424 | -0.47118258E-02 |
28 | 5 | -5.1608121 | 0.89965799E-04 | -4.4213154 | 0.62814943E-01 |
29 | 4 | 32.871256 | 0.73775273E-03 | 21.362378 | -0.42037561 |
30 | 3 | -110.94624 | 0.16114037E-02 | -55.469893 | 1.5111496 |
31 | 2 | 196.85374 | 0.90819125E-03 | 77.733479 | -2.8963115 |
32 | 1 | -171.06207 | 0.97128343E-04 | -55.213590 | 2.7437919 |
33 | 0 | 57.057407 | 0.55402955E-06 | 15.565444 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.57_SHGC_0.39 | 30 | 1 | VerySmooth | 3.241 | 0.385 | 0.305 | 0.391 |
2 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 31 | 1 | VerySmooth | 5.779 | 0.390 | 0.223 | 0.391 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.30403 | 0.46623 | 0.46623 | 0.39000 | 0.13867 | 0.18233 | 0.00000 | 0.84000 | 0.84000 | 1.43763E-002 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.22227 | 0.21773 | 0.21773 | 0.39000 | 0.13867 | 0.18233 | 0.00000 | 0.84000 | 0.84000 | 0.30192 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.727 | 0.1878 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
31 | SKYLIGHTS_R2C4 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
32 | SKYLIGHTS_R2C1 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
33 | SKYLIGHTS_R2C2 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
34 | SKYLIGHTS_R2C3 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C3 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C1 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C2 | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
39 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
40 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
42 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
43 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
44 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
45 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
46 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
47 | POINT_OF_SALE_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
48 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
49 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
50 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
52 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
54 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | FRONT_RETAIL_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
58 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
59 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
60 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
62 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
63 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
64 | FRONT_ENTRY_ROOF | 0 | 2292.12 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
65 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.448 | 1.180E-003 | 5.356E-004 | 0.697 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.367 | 2.293E-004 | 1.864E-004 | 0.135 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 2.497E-002 | 2.080E-003 | 6.862E-004 | 1.228 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 1.419 | 0.118 | 3.899E-002 | 69.771 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 23767.84798 | 28521.41757 | 1.74584 | 2.09501 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 27.37000 | 1.44457E-002 | 379.89000 | 61.34184 | 0.28946 | 0.00000 |
2 | BACK_SPACE | Heating | 26735.26163 | 32082.31395 | 1.17040 | 1.40448 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 379.89000 | 61.34184 | 0.28946 | 0.00000 |
3 | CORE_RETAIL | Cooling | 94668.03136 | 113601.63763 | 7.20543 | 8.64651 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 34.24167 | 1.44457E-002 | 1600.48290 | 258.43418 | 2.43898 | 0.00000 |
4 | CORE_RETAIL | Heating | 65103.82695 | 78124.59233 | 2.81684 | 3.38020 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 1600.48290 | 258.43418 | 2.43898 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 13807.06380 | 16568.47657 | 1.05089 | 1.26107 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 34.30500 | 1.44457E-002 | 150.81000 | 24.35169 | 0.22982 | 0.00000 |
6 | POINT_OF_SALE | Heating | 12778.85159 | 15334.62190 | 0.56131 | 0.67357 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 150.81000 | 24.35169 | 0.22982 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 11450.99911 | 13741.19893 | 0.87157 | 1.04588 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 34.30500 | 1.44457E-002 | 150.81000 | 24.35169 | 0.22982 | 0.00000 |
8 | FRONT_RETAIL | Heating | 12779.65209 | 15335.58251 | 0.56135 | 0.67362 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 150.81000 | 24.35169 | 0.22982 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.82869E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40000 | 1.44457E-002 | 12.00000 | 0.00000 | 1.82869E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 51081.02966 | 61297.23559 | 2.27534 | 2.73041 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -6.30000 | 2.29779E-003 | 12.00000 | 0.00000 | 1.82869E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 30744.43 | 2.11863 | 2.11863 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 40419.29 | 1.40448 | 1.40448 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 141670.36 | 8.64651 | 8.64651 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 152764.74 | 3.38020 | 3.38020 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 19129.62 | 1.26107 | 1.26107 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 22279.56 | 0.67357 | 0.67357 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 16345.45 | 1.04588 | 1.04588 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 22280.51 | 0.67362 | 0.67362 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.09501 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 8.64651 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.26107 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.04588 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 2.73041 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 2.73041 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 61349.88862 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.09501 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.09501 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.09501 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.09501 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.11863 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.11863 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.98885 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 8.64651 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 8.64651 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 8.64651 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 8.64651 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 8.64651 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 8.64651 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.26107 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.26107 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.26107 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.26107 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.26107 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.26107 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.04588 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.04588 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.04588 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.04588 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04588 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04588 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 2.11863 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 8.64651 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.26107 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 1.04588 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.11863 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.28946 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.11863 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.11863 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.11863 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.11863 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.11863 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.05932 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.11863 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 40605.70949 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 43317.84000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 21658.92000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 43317.84000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72866 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72866 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72866 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72866 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 43317.84000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 55768.36221 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.11863 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2318.84887 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 55768.36221 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 8.64651 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.43898 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 8.64651 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 8.64651 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 8.64651 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 8.64651 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 8.64651 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 4.32326 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 8.64651 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 193564.76547 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 204151.01000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 102075.50500 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 204151.01000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68876 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68876 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68876 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68876 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 204151.01000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 270401.33149 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 8.64651 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 15987.84163 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 270401.33149 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.26107 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.22982 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.26107 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.26107 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.26107 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.26107 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.26107 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.63054 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.26107 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24910.65640 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 26511.47000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13255.73500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 26511.47000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72049 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72049 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72049 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72049 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 26511.47000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 35341.28060 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.26107 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1437.75634 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 35341.28060 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04588 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.22982 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04588 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04588 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04588 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04588 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04588 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52294 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04588 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21778.04023 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23086.13000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11543.06500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 23086.13000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70672 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70672 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70672 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70672 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23086.13000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 30556.98607 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04588 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1192.41676 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 30556.98607 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 41652.3 | 9.83 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 197336.3 | 11.90 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 25519.6 | 107.67 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 22262.8 | 134.66 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 25 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.841 | 2.841 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 1591.92 | 1600.48 | 1593.79 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
32 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
33 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
34 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | N/A | 5.779 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
40 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.57_SHGC_0.39 | N/A | 3.241 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
45 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.57_SHGC_0.39 | N/A | 3.241 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
54 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
56 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
57 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
58 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.57_SHGC_0.39 | N/A | 3.241 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | |
1 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C4 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
2 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C1 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
3 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C2 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
4 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R2C3 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
5 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C3 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
6 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C1 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
7 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C4 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A | |||
8 | SKYLIGHT_FRAME | Frame | SKYLIGHTS_R1C2 | Window5 Detailed Fenestration | N/A | N/A | 0.23 | 0.23 | * | N/A | N/A | 6.00E-002 | N/A |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 10 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 6.9170090116E-002 | 0.2796607270 | Pass | Pass | 0.1232845920 | 0.3025274864 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 3.8305895832E-002 | 0.1356470477 | Pass | Pass | 0.3500264077 | 2.8117283196 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 7.9628923045E-002 | 0.2848263730 | Pass | Pass | 0.2142238495 | 0.7991262300 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 8.1280792115E-002 | 0.3281409974 | Pass | Pass | 9.8608758532E-002 | 0.3686000125 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.1144433538 | 0.4852919377 | Pass | Pass | 9.0281141774E-002 | 0.5069913755 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | -6.30 | 0.00 | -6.30 | Wetbulb [C] | 5.30 | 320.00 |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40 | 9.50 | 23.50 | Wetbulb [C] | 4.00 | 300.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 1600.48 | 1591.92 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_1.02_SHGC_0.39 | 0.84 | 0.23 | 0.00 | 1.07 | 1.07 | 5.779 | 0.390 | 0.391 | 283.913 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.57_SHGC_0.39 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 3.241 | 0.385 | 0.391 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.57_SHGC_0.39 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 3.241 | 0.385 | 0.391 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.57_SHGC_0.39 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 3.241 | 0.385 | 0.391 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 92.49 | 3.476 | 0.385 | 0.391 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 92.49 | 3.476 | 0.385 | 0.391 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 9.0309 | 379.89 | 3430.76 | LightsWired | BLDG_LIGHT_BACK_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 43.96 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 18.2986 | 1600.48 | 29286.67 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 375.23 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 18.2986 | 150.81 | 2759.62 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 35.36 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 18.2986 | 150.81 | 2759.62 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 35.36 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 13.9931 | 12.00 | 167.92 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 2.15 |
Interior Lighting Total | 16.7414 | 2293.99 | 38404.58 | 492.05 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7321.52 | AstronomicalClock | - | 83.77 | 83.77 | 115.13 | |
Exterior Lighting Total | 7321.52 | 115.13 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 43317.84 | 31563.98 | 11753.86 | 0.73 | 3.30 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 204151.01 | 140611.05 | 63539.96 | 0.69 | 3.23 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 26511.47 | 19101.25 | 7410.22 | 0.72 | 3.50 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23086.13 | 16315.43 | 6770.70 | 0.71 | 3.50 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 41652.3 | 9.83 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 197336.3 | 11.90 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 25519.6 | 107.67 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 22262.8 | 134.66 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 61349.89 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 55768.36 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 270401.33 | 0.79 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 35341.28 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 30556.99 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.57 | 622.50 | 2.73 | 2988.45 | 1094.51 | 1.00 | 1.23 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 2.12 | 2318.85 | 1094.51 | 1.00 | 1.28 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1110.54 | 8.65 | 15987.84 | 1849.05 | 1.00 | 1.13 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.26 | 1437.76 | 1140.11 | 1.00 | 1.31 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.05 | 1192.42 | 1140.11 | 1.00 | 1.35 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 23767.85 | 28521.42 | 75.08 | 1.746 | 2.095 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00953 | 27.37 | 0.01445 | 0.289 | 0.00 |
CORE_RETAIL | 94668.03 | 113601.64 | 70.98 | 7.205 | 8.647 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 23.89 | 23.89 | 0.00912 | 34.24 | 0.01445 | 2.439 | 0.00 |
POINT_OF_SALE | 13807.06 | 16568.48 | 109.86 | 1.051 | 1.261 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 23.89 | 23.89 | 0.00896 | 34.30 | 0.01445 | 0.230 | 0.00 |
FRONT_RETAIL | 11451.00 | 13741.20 | 91.12 | 0.872 | 1.046 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 23.89 | 23.89 | 0.00905 | 34.30 | 0.01445 | 0.230 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.018 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.05 | 100.00 | 0.00001 | 34.40 | 0.01445 | 0.018 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 26735.26 | 32082.31 | 84.45 | 1.170 | 1.404 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00764 | -6.30 | 0.00230 | 0.289 | 0.00 |
CORE_RETAIL | 65103.83 | 78124.59 | 48.81 | 2.817 | 3.380 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00753 | -6.30 | 0.00230 | 2.439 | 0.00 |
POINT_OF_SALE | 12778.85 | 15334.62 | 101.68 | 0.561 | 0.674 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00773 | -6.30 | 0.00230 | 0.230 | 0.00 |
FRONT_RETAIL | 12779.65 | 15335.58 | 101.69 | 0.561 | 0.674 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00773 | -6.30 | 0.00230 | 0.230 | 0.00 |
FRONT_ENTRY | 51081.03 | 61297.24 | 5108.10 | 2.275 | 2.730 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.02 | 0.00568 | -6.30 | 0.00230 | 0.018 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 2.12 | 2.12 | 1.40 | 1.40 | 2.1186 | 2.0950 | 2.1186 | 0.9889 | 1.0000 |
PSZ-AC:2 | 8.65 | 8.65 | 3.38 | 3.38 | 8.6465 | 8.6465 | 8.6465 | 1.0000 | 1.0000 |
PSZ-AC:3 | 1.26 | 1.26 | 0.67 | 0.67 | 1.2611 | 1.2611 | 1.2611 | 1.0000 | 1.0000 |
PSZ-AC:4 | 1.05 | 1.05 | 0.67 | 0.67 | 1.0459 | 1.0459 | 1.0459 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 61349.889 | 61349.889 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 61349.89 | 61349.89 | 2.730407 | 20.84 | 12.21 | 0.00566186 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.02 | 0.00568454 | 35.5166 | 61297.24 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 43317.840 | 0.000 | 2.118630 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 43317.84 | 34791.87 | 2.118630 | 25.34 | 17.61 | 0.00990247 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 13.6625 | 23.89 | 0.00953043 | 49.7226 | 23018.09 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 55768.362 | 55768.362 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 55768.36 | 55768.36 | 2.118627 | 15.33 | 10.83 | 0.00653654 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 13.6625 | 21.11 | 0.00763691 | 47.3102 | 26735.26 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 204151.010 | 0.000 | 8.646510 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 204151.01 | 152792.33 | 8.646510 | 26.86 | 18.67 | 0.01062604 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 28.2077 | 23.89 | 0.00912344 | 47.6238 | 94595.68 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 270401.331 | 270401.331 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 270401.33 | 270401.33 | 8.646512 | 1.26 | 0.50 | 0.00375429 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 28.2077 | 21.11 | 0.00752850 | 46.6457 | 65103.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 26511.470 | 0.000 | 1.261070 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 26511.47 | 21269.43 | 1.261070 | 25.80 | 17.81 | 0.00995626 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 18.2242 | 23.89 | 0.00895561 | 46.7602 | 13806.14 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 35341.281 | 35341.281 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 35341.28 | 35341.28 | 1.261068 | 11.65 | 8.51 | 0.00587582 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 18.2242 | 21.11 | 0.00772887 | 47.8723 | 12778.85 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 23086.130 | 0.000 | 1.045880 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 23086.13 | 17952.10 | 1.045880 | 26.20 | 18.16 | 0.01023446 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 21.9739 | 23.89 | 0.00904812 | 47.2363 | 11449.55 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 30556.986 | 30556.986 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 30556.99 | 30556.99 | 1.045879 | 11.65 | 8.51 | 0.00587596 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 21.9739 | 21.11 | 0.00772890 | 47.8725 | 12779.65 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 61349.889 | 61349.889 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 2.730407 | 3.16993818 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 61349.89 | 61349.89 | 1.0000 | 3.16993818 | 2.730407 | 20.84 | 12.21 | 0.00566186 | 35317.6 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 61349.89 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.04 | 0.00568454 | 21.02 | 0.00568454 | 35.5166 | 61297.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 43317.840 | 0.000 | 2.118630 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.2482 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 43317.84 | 34791.87 | 1.0000 | 2.45967973 | 2.118630 | 25.34 | 17.61 | 0.00990247 | 50689.6 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 43317.84 | 34.40 | 0.01444567 | 23.51 | 0.28945795 | 13.6625 | 23.89 | 0.00917708 | 23.89 | 0.00953043 | 49.7226 | 23018.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 55768.362 | 55768.362 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.118627 | 2.45967622 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 55768.36 | 55768.36 | 1.0000 | 2.45967622 | 2.118627 | 15.33 | 10.83 | 0.00653654 | 31939.3 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 55768.36 | -6.30 | 0.00229779 | -6.30 | 0.28945795 | 13.6625 | 20.95 | 0.00763691 | 21.11 | 0.00763691 | 47.3102 | 26735.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 204151.010 | 0.000 | 8.646510 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.5933 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 204151.01 | 152792.33 | 1.0000 | 10.03839527 | 8.646510 | 26.86 | 18.67 | 0.01062604 | 54090.9 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 204151.01 | 34.40 | 0.01444567 | 23.51 | 2.43898389 | 28.2077 | 23.89 | 0.00912367 | 23.89 | 0.00912344 | 47.6238 | 94595.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 270401.331 | 270401.331 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 8.646512 | 10.03839785 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 270401.33 | 270401.33 | 1.0000 | 10.03839785 | 8.646512 | 1.26 | 0.50 | 0.00375429 | 10664.8 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 270401.33 | -6.30 | 0.00229779 | -6.30 | 2.43898389 | 28.2077 | 20.85 | 0.00752850 | 21.11 | 0.00752850 | 46.6457 | 65103.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 26511.470 | 0.000 | 1.261070 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.3482 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 26511.47 | 21269.43 | 1.0000 | 1.46407269 | 1.261070 | 25.80 | 17.81 | 0.00995626 | 51306.2 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26511.47 | 34.40 | 0.01444567 | 23.51 | 0.22982011 | 18.2242 | 23.89 | 0.00895568 | 23.89 | 0.00895561 | 46.7602 | 13806.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 35341.281 | 35341.281 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.261068 | 1.46407061 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 35341.28 | 35341.28 | 1.0000 | 1.46407061 | 1.261068 | 11.65 | 8.51 | 0.00587582 | 26526.1 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35341.28 | -6.30 | 0.00229779 | -6.30 | 0.22982011 | 18.2242 | 20.94 | 0.00772887 | 21.11 | 0.00772887 | 47.8723 | 12778.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 23086.130 | 0.000 | 1.045880 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8654 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 23086.13 | 17952.10 | 1.0000 | 1.21424214 | 1.045880 | 26.20 | 18.16 | 0.01023446 | 52419.1 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23086.13 | 34.40 | 0.01444567 | 23.51 | 0.22982011 | 21.9739 | 23.89 | 0.00904830 | 23.89 | 0.00904812 | 47.2363 | 11449.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 30556.986 | 30556.986 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.045879 | 1.21424075 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 30556.99 | 30556.99 | 1.0000 | 1.21424075 | 1.045879 | 11.65 | 8.51 | 0.00587596 | 26527.0 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30556.99 | -6.30 | 0.00229779 | -6.30 | 0.22982011 | 21.9739 | 20.94 | 0.00772890 | 21.11 | 0.00772890 | 47.8725 | 12779.65 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2803.50 | 2444.00 | 877.67 |
CORE_RETAIL | 2798.00 | 2028.83 | 525.33 |
POINT_OF_SALE | 2886.67 | 1661.33 | 341.17 |
FRONT_RETAIL | 2839.17 | 2158.50 | 660.83 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3456.33 | 2676.83 | 1088.17 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 25.00 | 19.00 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 28.17 | 0.00 | 0.00 |
POINT_OF_SALE | 13.33 | 130.83 | 0.00 | 0.00 |
FRONT_RETAIL | 20.33 | 56.00 | 0.00 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 28.00 | 162.17 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.39 | 61.34 | 2317.33 | 0.458 | 0.053 | 0.000 | 0.000 |
CORE_RETAIL | 128.05 | 258.43 | 9762.95 | 0.916 | 0.010 | 0.000 | 0.000 |
POINT_OF_SALE | 12.07 | 24.35 | 919.94 | 0.916 | 0.058 | 0.000 | 0.000 |
FRONT_RETAIL | 12.07 | 24.35 | 919.94 | 0.915 | 0.057 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.39 | 61.34 | 2317.33 | 0.439 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.05 | 258.43 | 9762.95 | 0.879 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.07 | 24.35 | 919.94 | 0.879 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.07 | 24.35 | 919.94 | 0.879 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 11 | 11 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
Electricity:Building | 687.20 | 3715.40 | 01-JAN-00:10 | 45335.16 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 93.95 | 631.39 | 01-JAN-00:10 | 5846.82 | 02-JAN-09:10 |
InteriorLights:Electricity | 492.05 | 1920.23 | 01-JAN-00:10 | 34564.13 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 43.96 | 171.54 | 01-JAN-00:10 | 3087.68 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 492.05 | 1920.23 | 01-JAN-00:10 | 34564.13 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 459.53 | 2239.77 | 01-JAN-00:10 | 31010.61 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 375.23 | 1464.33 | 01-JAN-00:10 | 26358.01 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 88.28 | 624.80 | 01-JAN-00:10 | 5404.55 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 35.36 | 137.98 | 01-JAN-00:10 | 2483.66 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 43.30 | 211.05 | 01-JAN-00:10 | 2922.06 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 35.36 | 137.98 | 01-JAN-00:10 | 2483.66 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 2.15 | 8.40 | 01-JAN-00:10 | 151.13 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 2.15 | 8.40 | 01-JAN-00:10 | 151.13 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
ElectricityPurchased:Plant | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
Cogeneration:ElectricityPurchased | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
ElectricityNet:Plant | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
Cogeneration:ElectricityNet | 1654.56 | 3715.40 | 26-FEB-07:20 | 141062.85 | 08-JUL-14:50 |
Electricity:HVAC | 852.23 | 0.00 | 01-JAN-00:10 | 95727.68 | 08-JUL-14:50 |
Fans:Electricity | 432.87 | 0.00 | 01-JAN-00:10 | 23925.31 | 01-JAN-08:50 |
General:Fans:Electricity | 432.87 | 0.00 | 01-JAN-00:10 | 23925.31 | 01-JAN-08:50 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 419.36 | 0.00 | 01-JAN-00:10 | 74790.82 | 08-JUL-14:50 |
ExteriorLights:Electricity | 115.13 | 0.00 | 01-JAN-07:50 | 7321.52 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 115.13 | 0.00 | 01-JAN-07:50 | 7321.52 | 01-JAN-00:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 323.74 | 1862.00 | 26-FEB-10:10 | 279821.17 | 12-FEB-08:10 |
Gas:Plant | 93.27 | 1862.00 | 19-JAN-05:10 | 5063.07 | 01-FEB-12:10 |
WaterSystems:Gas | 93.27 | 1862.00 | 19-JAN-05:10 | 5063.07 | 01-FEB-12:10 |
Water Heater:WaterSystems:Gas | 93.27 | 1862.00 | 19-JAN-05:10 | 5063.07 | 01-FEB-12:10 |
Gas:HVAC | 230.47 | 0.00 | 01-JAN-00:10 | 277959.17 | 12-FEB-08:10 |
Heating:Gas | 230.47 | 0.00 | 01-JAN-00:10 | 277959.17 | 12-FEB-08:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2445.23 | 0.00 | 01-JAN-00:10 | 348350.76 | 12-FEB-08:10 |
EnergyTransfer:Building | 905.71 | 0.00 | 01-JAN-00:10 | 130888.68 | 08-JAN-08:10 |
EnergyTransfer:Zone:BACK_SPACE | 121.96 | 0.00 | 01-JAN-00:10 | 46317.34 | 12-FEB-07:10 |
Heating:EnergyTransfer | 101.42 | 0.00 | 01-JAN-00:10 | 124977.32 | 12-FEB-08:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 19.17 | 0.00 | 01-JAN-00:10 | 46317.34 | 12-FEB-07:10 |
Cooling:EnergyTransfer | 804.29 | 0.00 | 01-JAN-00:10 | 100234.15 | 07-JUL-15:00 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 102.79 | 0.00 | 01-JAN-00:10 | 17030.55 | 08-JUL-15:30 |
EnergyTransfer:Zone:CORE_RETAIL | 550.57 | 0.00 | 01-JAN-00:10 | 86601.48 | 16-JAN-08:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 10.12 | 0.00 | 01-JAN-00:10 | 76969.68 | 13-FEB-06:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 540.45 | 0.00 | 01-JAN-00:10 | 64122.85 | 07-JUL-15:00 |
EnergyTransfer:Zone:POINT_OF_SALE | 98.87 | 0.00 | 01-JAN-00:10 | 20578.53 | 12-FEB-07:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 3.41 | 0.00 | 01-JAN-00:10 | 20578.53 | 12-FEB-07:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 95.46 | 0.00 | 01-JAN-00:10 | 11780.40 | 10-OCT-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 71.30 | 0.00 | 01-JAN-00:10 | 21471.47 | 12-FEB-07:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 5.71 | 0.00 | 01-JAN-00:10 | 21471.47 | 12-FEB-07:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 65.59 | 0.00 | 01-JAN-00:10 | 9865.69 | 10-OCT-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 63.01 | 0.00 | 01-JAN-00:10 | 48320.25 | 11-FEB-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 63.01 | 0.00 | 01-JAN-00:10 | 48320.25 | 11-FEB-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 8.07 | 01-JAN-07:10 |
EnergyTransfer:HVAC | 1539.52 | 0.00 | 01-JAN-00:10 | 227316.31 | 08-JUL-14:00 |
HeatingCoils:EnergyTransfer | 183.58 | 0.00 | 01-JAN-00:10 | 220979.58 | 12-FEB-08:10 |
CoolingCoils:EnergyTransfer | 1355.94 | 0.00 | 01-JAN-00:10 | 227316.31 | 08-JUL-14:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 19.170 | -102.790 | 0.000 | 0.000 | 38.203 | 43.956 | 49.992 | 0.000 | 0.000 | 1.161 | 0.001 | 0.000 | 0.000 | 0.000 | -19.919 | -29.772 |
CORE_RETAIL | 0.000 | 0.000 | 10.116 | -540.441 | 0.000 | 0.000 | 160.010 | 375.227 | 84.299 | 13.178 | 0.000 | 0.951 | 0.000 | 0.000 | -7.657 | 0.000 | -17.943 | -77.740 |
POINT_OF_SALE | 0.000 | 0.000 | 3.414 | -95.458 | 0.000 | 0.000 | 14.908 | 35.357 | 52.922 | 38.205 | 0.000 | 0.500 | 0.000 | 0.000 | -17.931 | 0.000 | -9.293 | -22.625 |
FRONT_RETAIL | 0.000 | 0.000 | 5.714 | -65.587 | 0.000 | 0.000 | 15.114 | 35.357 | 7.943 | 38.330 | 0.000 | 0.502 | 0.001 | 0.000 | -17.356 | 0.000 | -8.916 | -11.101 |
FRONT_ENTRY | 63.006 | -0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 2.151 | 0.000 | 7.556 | 0.000 | 0.646 | 0.000 | 0.000 | -3.614 | 0.000 | -67.523 | -2.222 |
Total Facility | 63.006 | -0.000 | 38.415 | -804.276 | 0.000 | 0.000 | 228.235 | 492.048 | 195.156 | 97.269 | 0.000 | 3.760 | 0.002 | 0.000 | -46.559 | 0.000 | -123.593 | -143.460 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 24-JUL-20:10 | 0.00 | 0.00 | 0.00 | -30426.71 | 0.00 | 0.00 | 0.00 | 686.15 | 613.14 | 0.00 | 0.00 | 352.30 | 28775.11 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 24-SEP-07:01 | 0.00 | 0.00 | 0.00 | -141086.11 | 0.00 | 0.00 | 0.00 | 1464.33 | 775.43 | 0.00 | 0.00 | 0.00 | 139188.98 | 0.00 | -218.94 | 0.00 | -123.69 | 0.00 |
POINT_OF_SALE | 12-NOV-19:10 | 0.00 | 0.00 | 0.00 | -18655.85 | 0.00 | 0.00 | 0.00 | 137.98 | 486.81 | 0.00 | 0.00 | 0.00 | 19798.30 | 0.00 | -1266.33 | 0.00 | -500.92 | 0.00 |
FRONT_RETAIL | 27-AUG-19:23 | 0.00 | 0.00 | 0.00 | -14803.98 | 0.00 | 0.00 | 0.00 | 137.98 | 73.07 | 24.46 | 0.00 | 278.23 | 14290.24 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | 01-JAN-07:02 | 0.00 | -80.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 258.35 | 0.00 | -128.08 | 0.00 | -58.01 | 0.00 |
Total Facility | 13-JUL-20:43 | 0.00 | 0.00 | 0.00 | -176029.93 | 0.00 | 0.00 | 0.00 | 7680.92 | 2393.56 | 0.00 | 0.00 | 0.00 | 167178.63 | 0.00 | -725.04 | 0.00 | -498.14 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 11-FEB-05:01 | 0.00 | 0.00 | 54414.78 | 0.00 | 0.00 | 0.00 | 0.00 | 171.54 | 459.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1593.39 | -53452.79 |
CORE_RETAIL | 17-JAN-06:02 | 0.00 | 0.00 | 234169.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1464.33 | 1033.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -500.00 | 0.00 | -720.11 | -235447.40 |
POINT_OF_SALE | 01-JAN-07:01 | 0.00 | 0.00 | 33497.60 | 0.00 | 0.00 | 0.00 | 0.00 | 137.98 | 486.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -682.57 | 0.00 | -393.88 | -33045.94 |
FRONT_RETAIL | 01-JAN-07:01 | 0.00 | 0.00 | 29029.96 | 0.00 | 0.00 | 0.00 | 0.00 | 137.98 | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -642.41 | 0.00 | -358.22 | -28240.38 |
FRONT_ENTRY | 11-FEB-18:00 | 48316.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 136.21 | 0.00 | -441.85 | 0.00 | -48162.18 | 0.00 |
Total Facility | 13-FEB-06:01 | 1890.79 | 0.00 | 312676.50 | 0.00 | 0.00 | 0.00 | 0.00 | 1920.23 | 2393.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6246.63 | 0.00 | -5033.94 | -307600.52 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.0950 | 0.0000 | 61.3418 | 1.0000 | 0.2895 | 2.1186 | 0.1366 | 1.0000 | 0.2895 | 0.1366 | ||
PSZ-AC:2 | 8.6465 | 0.0000 | 258.4342 | 1.0000 | 2.4390 | 8.6465 | 0.2821 | 1.0000 | 2.4390 | 0.2821 | ||
PSZ-AC:3 | 1.2611 | 0.0000 | 24.3517 | 1.0000 | 0.2298 | 1.2611 | 0.1822 | 1.0000 | 0.2298 | 0.1822 | ||
PSZ-AC:4 | 1.0459 | 0.0000 | 24.3517 | 1.0000 | 0.2298 | 1.0459 | 0.2197 | 1.0000 | 0.2298 | 0.2197 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.0950 | 0.0000 | 61.3418 | 1.0000 | 0.2895 | 2.0950 | 1.0000 | 1.0000 | 0.2895 | 0.1382 | ||
PSZ-AC:2 | 8.6465 | 0.0000 | 258.4342 | 1.0000 | 2.4390 | 8.6465 | 1.0000 | 1.0000 | 2.4390 | 0.2821 | ||
PSZ-AC:3 | 1.2611 | 0.0000 | 24.3517 | 1.0000 | 0.2298 | 1.2611 | 1.0000 | 1.0000 | 0.2298 | 0.1822 | ||
PSZ-AC:4 | 1.0459 | 0.0000 | 24.3517 | 1.0000 | 0.2298 | 1.0459 | 1.0000 | 1.0000 | 0.2298 | 0.2197 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000762 | 379.89 | 0.2895 | 1.0000 | 0.2895 | 1.000 | 0.2895 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001524 | 1600.48 | 2.4390 | 1.0000 | 2.4390 | 1.000 | 2.4390 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001524 | 150.81 | 0.2298 | 1.0000 | 0.2298 | 1.000 | 0.2298 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001524 | 150.81 | 0.2298 | 1.0000 | 0.2298 | 1.000 | 0.2298 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000762 | 379.8900 | 0.2895 | 0.2895 | 0.2895 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001524 | 1600.4829 | 2.4390 | 2.4390 | 2.4390 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001524 | 150.8100 | 0.2298 | 0.2298 | 0.2298 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001524 | 150.8100 | 0.2298 | 0.2298 | 0.2298 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.0950 | 2.0950 | 2.0950 | 0.2895 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 8.6465 | 8.6465 | 8.6465 | 2.4390 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2611 | 1.2611 | 1.2611 | 0.2298 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0459 | 1.0459 | 1.0459 | 0.2298 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.0950 | 2.1186 | 2.0950 | 2.0950 | 0.2895 | 1.0000 |
PSZ-AC:2 | 8.6465 | 8.6465 | 8.6465 | 8.6465 | 2.4390 | 1.0000 |
PSZ-AC:3 | 1.2611 | 1.2611 | 1.2611 | 1.2611 | 0.2298 | 1.0000 |
PSZ-AC:4 | 1.0459 | 1.0459 | 1.0459 | 1.0459 | 0.2298 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.0950 | 2.0950 | 2.0950 | 0.2895 | 0.2061 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 8.6465 | 8.6465 | 8.6465 | 2.4390 | 0.7215 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2611 | 1.2611 | 1.2611 | 0.2298 | 0.3412 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0459 | 1.0459 | 1.0459 | 0.2298 | 0.3412 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.0950 | 2.0950 | 2.0950 | 2.0950 | 0.2895 | 1.0000 |
PSZ-AC:2 | 8.6465 | 8.6465 | 8.6465 | 8.6465 | 2.4390 | 1.0000 |
PSZ-AC:3 | 1.2611 | 1.2611 | 1.2611 | 1.2611 | 0.2298 | 1.0000 |
PSZ-AC:4 | 1.0459 | 1.0459 | 1.0459 | 1.0459 | 0.2298 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:06
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 230.47 | 277959.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 419.36 | 74790.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 492.05 | 34564.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 115.13 | 7321.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 432.87 | 23925.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 93.27 | 5063.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 1654.56 |
Natural Gas | 0.00 | 323.74 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 1978.30 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 214.49 |
Space Heating | 0.00 |
Space Cooling | 182.81 |
Fans (All) | 188.70 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 721.26 |
Subtotal | 721.26 |
Natural Gas [MJ/m2] | |
Space Heating | 100.47 |
Service Water Heating | 40.66 |
Miscellaneous (All) | 141.13 |
Subtotal | 141.13 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 24.87 |
Space Heating | 11.65 |
Space Cooling | 21.20 |
Fans (All) | 21.88 |
Service Water Heating | 4.71 |
Receptacle Equipment | 9.86 |
Miscellaneous | 5.82 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3609. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_SETBACK | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
HTGSETP_SCH_PSZ_AC_2 | CORE_RETAIL DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2004
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.999371E+11 |
February | 0.000 | 0.559324E+11 |
March | 0.000 | 0.944558E+10 |
April | 0.000 | 0.263043E+10 |
May | 0.000 | 0.448843E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.624118E+08 |
October | 0.000 | 0.270580E+10 |
November | 0.000 | 0.129355E+11 |
December | 0.000 | 0.467750E+11 |
Annual Sum or Average | 0.230469E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.999371E+11 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.330035E+09 | 3204.73 | 03-JAN-15:30 | 2.80 | 2.54 | 0.170563E+10 | 2451.25 | 31-JAN-15:39 | 20.37 | 13.38 |
February | 0.851092E+09 | 5426.23 | 28-FEB-16:00 | 23.30 | 12.51 | 0.168525E+10 | 2451.30 | 22-FEB-15:09 | 19.07 | 12.79 |
March | 0.343241E+10 | 15619.71 | 30-MAR-21:20 | 23.53 | 16.74 | 0.215429E+10 | 2451.31 | 11-MAR-11:20 | 19.43 | 13.14 |
April | 0.630252E+10 | 13340.35 | 17-APR-20:33 | 20.93 | 14.55 | 0.212611E+10 | 2451.34 | 15-APR-15:50 | 28.22 | 15.91 |
May | 0.113649E+11 | 16402.67 | 19-MAY-21:40 | 22.77 | 15.86 | 0.222913E+10 | 2451.30 | 13-MAY-15:00 | 27.20 | 15.42 |
June | 0.171703E+11 | 30124.03 | 14-JUN-20:10 | 27.62 | 20.45 | 0.220141E+10 | 2451.30 | 10-JUN-11:30 | 24.75 | 13.81 |
July | 0.194524E+11 | 30429.51 | 24-JUL-20:10 | 28.53 | 20.28 | 0.218723E+10 | 2451.22 | 29-JUL-13:30 | 20.85 | 20.85 |
August | 0.203400E+11 | 30390.13 | 25-AUG-20:10 | 26.10 | 18.80 | 0.228098E+10 | 2451.18 | 26-AUG-10:09 | 27.48 | 20.44 |
September | 0.132162E+11 | 28303.63 | 08-SEP-20:10 | 27.43 | 21.81 | 0.215585E+10 | 2451.31 | 14-SEP-14:00 | 26.10 | 14.83 |
October | 0.640745E+10 | 14894.42 | 10-OCT-21:23 | 21.10 | 18.68 | 0.213684E+10 | 2451.31 | 12-OCT-14:09 | 20.60 | 11.89 |
November | 0.275793E+10 | 6978.43 | 04-NOV-16:00 | 21.10 | 18.17 | 0.194646E+10 | 2451.25 | 17-NOV-15:09 | 18.30 | 9.68 |
December | 0.116720E+10 | 4713.37 | 13-DEC-15:50 | 17.38 | 16.89 | 0.180556E+10 | 2451.25 | 11-DEC-15:09 | 21.10 | 14.71 |
Annual Sum or Average | 0.102792E+12 | 0.246147E+11 | ||||||||
Minimum of Months | 0.330035E+09 | 3204.73 | 2.80 | 2.54 | 0.168525E+10 | 2451.18 | 18.30 | 9.68 | ||
Maximum of Months | 0.203400E+11 | 30429.51 | 28.53 | 21.81 | 0.228098E+10 | 2451.34 | 28.22 | 20.85 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.159300E+11 | 63840.62 | 27-JAN-07:05 | -6.7 | -7.8 | 0.731354E+10 | 10327.26 | 30-JAN-15:09 | 16.70 | 10.50 |
February | 0.194278E+11 | 66529.31 | 03-FEB-06:05 | -8.4 | -9.8 | 0.725791E+10 | 10327.58 | 22-FEB-15:00 | 14.40 | 13.41 |
March | 0.359085E+11 | 66499.57 | 29-MAR-20:20 | 23.53 | 17.16 | 0.924016E+10 | 10327.36 | 21-MAR-14:30 | 12.80 | 11.03 |
April | 0.445587E+11 | 74167.52 | 09-APR-19:15 | 16.10 | 9.54 | 0.899882E+10 | 10327.58 | 15-APR-15:39 | 28.13 | 15.85 |
May | 0.584937E+11 | 105791.28 | 19-MAY-20:43 | 24.18 | 16.42 | 0.939429E+10 | 10327.55 | 10-MAY-14:30 | 21.15 | 12.32 |
June | 0.693681E+11 | 130733.59 | 04-JUN-18:10 | 30.40 | 19.27 | 0.927364E+10 | 10327.35 | 08-JUN-14:09 | 24.18 | 13.60 |
July | 0.727055E+11 | 126212.46 | 24-JUL-20:10 | 28.53 | 20.28 | 0.921492E+10 | 10327.03 | 29-JUL-13:30 | 20.85 | 20.85 |
August | 0.752919E+11 | 121940.30 | 25-AUG-20:10 | 26.10 | 18.80 | 0.960990E+10 | 10326.87 | 04-AUG-14:39 | 27.23 | 23.05 |
September | 0.572692E+11 | 141099.89 | 24-SEP-07:01 | 17.85 | 15.55 | 0.908133E+10 | 10327.01 | 29-SEP-14:30 | 20.85 | 17.55 |
October | 0.415904E+11 | 68845.80 | 18-OCT-21:00 | 23.30 | 22.56 | 0.902290E+10 | 10327.37 | 13-OCT-14:09 | 20.78 | 11.83 |
November | 0.285583E+11 | 55337.34 | 22-NOV-07:05 | -3.2 | -3.9 | 0.831717E+10 | 10327.10 | 04-NOV-10:09 | 16.70 | 16.44 |
December | 0.213475E+11 | 59662.91 | 18-DEC-07:05 | -5.1 | -6.8 | 0.791648E+10 | 10327.28 | 16-DEC-15:09 | 14.22 | 10.42 |
Annual Sum or Average | 0.540450E+12 | 0.104641E+12 | ||||||||
Minimum of Months | 0.159300E+11 | 55337.34 | -8.4 | -9.8 | 0.725791E+10 | 10326.87 | 12.80 | 10.42 | ||
Maximum of Months | 0.752919E+11 | 141099.89 | 30.40 | 22.56 | 0.960990E+10 | 10327.58 | 28.13 | 23.05 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.301111E+10 | 5658.15 | 28-JAN-15:20 | 12.20 | 4.53 | 0.741432E+09 | 973.13 | 30-JAN-15:00 | 16.70 | 10.50 |
February | 0.364947E+10 | 9075.84 | 21-FEB-14:40 | 22.43 | 10.94 | 0.706602E+09 | 973.16 | 22-FEB-15:20 | 18.13 | 13.10 |
March | 0.586925E+10 | 14838.60 | 30-MAR-20:43 | 23.98 | 16.89 | 0.877204E+09 | 973.20 | 11-MAR-11:20 | 19.43 | 13.14 |
April | 0.639407E+10 | 11622.14 | 16-APR-18:10 | 25.03 | 16.26 | 0.847089E+09 | 973.19 | 12-APR-14:50 | 28.40 | 16.89 |
May | 0.870375E+10 | 14546.74 | 19-MAY-20:43 | 24.18 | 16.42 | 0.884880E+09 | 973.14 | 13-MAY-12:09 | 24.08 | 13.83 |
June | 0.114601E+11 | 16910.82 | 13-JUN-20:08 | 29.22 | 21.94 | 0.873809E+09 | 973.15 | 10-JUN-10:39 | 23.17 | 13.61 |
July | 0.126724E+11 | 17380.60 | 02-JUL-18:43 | 28.68 | 20.61 | 0.868289E+09 | 973.09 | 29-JUL-13:30 | 20.85 | 20.85 |
August | 0.139612E+11 | 17393.36 | 27-AUG-19:23 | 28.05 | 20.93 | 0.905503E+09 | 973.07 | 04-AUG-14:30 | 28.35 | 23.39 |
September | 0.107352E+11 | 17449.05 | 08-SEP-21:23 | 25.30 | 21.55 | 0.855809E+09 | 973.10 | 14-SEP-14:00 | 26.10 | 14.83 |
October | 0.858874E+10 | 17095.49 | 10-OCT-20:43 | 21.28 | 18.87 | 0.855779E+09 | 973.17 | 14-OCT-12:39 | 20.73 | 13.27 |
November | 0.618926E+10 | 18655.96 | 12-NOV-19:10 | 13.72 | 8.26 | 0.809485E+09 | 973.15 | 09-NOV-15:00 | 20.00 | 12.39 |
December | 0.422486E+10 | 8491.98 | 12-DEC-14:00 | 22.80 | 17.06 | 0.804024E+09 | 973.16 | 16-DEC-14:30 | 14.40 | 10.34 |
Annual Sum or Average | 0.954593E+11 | 0.100299E+11 | ||||||||
Minimum of Months | 0.301111E+10 | 5658.15 | 12.20 | 4.53 | 0.706602E+09 | 973.07 | 14.40 | 10.34 | ||
Maximum of Months | 0.139612E+11 | 18655.96 | 29.22 | 21.94 | 0.905503E+09 | 973.20 | 28.40 | 23.39 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.164735E+10 | 4547.80 | 26-JAN-14:00 | 0.00 | -3.7 | 0.698780E+09 | 973.13 | 30-JAN-15:20 | 16.70 | 10.50 |
February | 0.206565E+10 | 6948.90 | 21-FEB-14:40 | 22.43 | 10.94 | 0.676041E+09 | 973.15 | 22-FEB-15:09 | 19.07 | 12.79 |
March | 0.349505E+10 | 11336.90 | 30-MAR-20:43 | 23.98 | 16.89 | 0.851195E+09 | 973.16 | 27-MAR-14:00 | 21.70 | 13.08 |
April | 0.390542E+10 | 9601.43 | 16-APR-18:10 | 25.03 | 16.26 | 0.834216E+09 | 973.16 | 14-APR-14:39 | 27.20 | 15.69 |
May | 0.574731E+10 | 11444.70 | 19-MAY-20:43 | 24.18 | 16.42 | 0.882051E+09 | 973.13 | 10-MAY-14:00 | 21.70 | 12.56 |
June | 0.834257E+10 | 14463.54 | 04-JUN-18:43 | 29.60 | 18.96 | 0.873398E+09 | 973.12 | 10-JUN-11:39 | 25.03 | 13.79 |
July | 0.950691E+10 | 14768.80 | 02-JUL-18:43 | 28.68 | 20.61 | 0.868263E+09 | 973.09 | 29-JUL-13:30 | 20.85 | 20.85 |
August | 0.106638E+11 | 14805.47 | 27-AUG-19:23 | 28.05 | 20.93 | 0.905506E+09 | 973.07 | 26-AUG-10:09 | 27.48 | 20.44 |
September | 0.772256E+10 | 14661.45 | 08-SEP-21:23 | 25.30 | 21.55 | 0.854821E+09 | 973.12 | 14-SEP-14:00 | 26.10 | 14.83 |
October | 0.598048E+10 | 14177.93 | 10-OCT-20:43 | 21.28 | 18.87 | 0.838249E+09 | 973.18 | 04-OCT-14:00 | 21.10 | 13.22 |
November | 0.394333E+10 | 7807.75 | 06-NOV-14:30 | 20.60 | 10.95 | 0.785701E+09 | 973.10 | 18-NOV-11:09 | 15.97 | 8.85 |
December | 0.256841E+10 | 6150.96 | 12-DEC-14:00 | 22.80 | 17.06 | 0.754986E+09 | 973.10 | 14-DEC-15:09 | 15.00 | 10.57 |
Annual Sum or Average | 0.655888E+11 | 0.982321E+10 | ||||||||
Minimum of Months | 0.164735E+10 | 4547.80 | 0.00 | -3.7 | 0.676041E+09 | 973.07 | 15.00 | 8.85 | ||
Maximum of Months | 0.106638E+11 | 14805.47 | 29.60 | 21.55 | 0.905506E+09 | 973.18 | 27.48 | 20.85 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 11746.28 | 80.66 | 01-JAN-07:02 | 11.10 | 10.21 | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 |
February | 2609.61 | 26.22 | 06-FEB-05:02 | 1.02 | -1.4 | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.50 | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.50 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.81 | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.81 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 20.93 | 18.59 | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 22.28 | 21.38 | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 25.13 | 21.87 | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 21.40 | 18.45 | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.45 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.59 | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.59 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 |
Annual Sum or Average | 14355.89 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 1.02 | -1.4 | 0.00 | 0.00 | 1.80 | 1.51 | ||
Maximum of Months | 11746.28 | 80.66 | 25.13 | 21.87 | 0.00 | 0.00 | 25.13 | 21.87 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.842212E+10 | 54273.55 | 19-JAN-05:01 | 12.20 |
February | 0.493725E+10 | 54414.66 | 11-FEB-05:01 | 11.78 |
March | 0.669674E+09 | 52190.20 | 22-MAR-04:01 | 6.60 |
April | 0.121575E+09 | 49873.55 | 07-APR-04:02 | 3.80 |
May | 3187328.13 | 1221.56 | 31-MAY-05:10 | 19.90 |
June | 4774647.66 | 1753.94 | 27-JUN-05:05 | 20.00 |
July | 3658380.28 | 1931.34 | 30-JUL-07:07 | 21.78 |
August | 2470673.79 | 1729.45 | 28-AUG-05:10 | 21.60 |
September | 4045775.52 | 2192.31 | 17-SEP-07:07 | 22.88 |
October | 61479871.93 | 39880.44 | 26-OCT-04:03 | 2.70 |
November | 0.927624E+09 | 52849.60 | 24-NOV-05:01 | 8.90 |
December | 0.401243E+10 | 53906.71 | 24-DEC-07:01 | 13.30 |
Annual Sum or Average | 0.191703E+11 | |||
Minimum of Months | 2470673.79 | 1221.56 | 2.70 | |
Maximum of Months | 0.842212E+10 | 54414.66 | 22.88 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.503464E+10 | 234165.39 | 17-JAN-06:02 | 4.72 |
February | 0.252601E+10 | 231147.55 | 15-FEB-07:02 | 4.40 |
March | 0.190414E+09 | 142973.51 | 23-MAR-06:03 | 6.10 |
April | 70418553.06 | 132923.91 | 07-APR-06:03 | 2.80 |
May | 6914071.39 | 5014.16 | 31-MAY-05:10 | 19.90 |
June | 22578886.02 | 10304.03 | 12-JUN-05:10 | 21.70 |
July | 29954762.87 | 11693.03 | 26-JUL-05:05 | 21.78 |
August | 18662185.38 | 15085.08 | 18-AUG-05:05 | 23.22 |
September | 24936756.18 | 13647.34 | 17-SEP-07:07 | 22.88 |
October | 39376918.62 | 132678.00 | 26-OCT-06:03 | 2.20 |
November | 0.386411E+09 | 153308.53 | 22-NOV-07:03 | -3.2 |
December | 0.176541E+10 | 213934.25 | 04-DEC-06:02 | -2.9 |
Annual Sum or Average | 0.101157E+11 | |||
Minimum of Months | 6914071.39 | 5014.16 | -3.2 | |
Maximum of Months | 0.503464E+10 | 234165.39 | 23.22 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.159099E+10 | 33497.16 | 01-JAN-07:01 | 11.10 |
February | 0.954365E+09 | 33447.65 | 11-FEB-05:01 | 11.78 |
March | 79535473.52 | 31653.72 | 22-MAR-04:01 | 6.60 |
April | 21300800.41 | 19087.72 | 06-APR-04:02 | 0.92 |
May | 64545.76 | 311.98 | 07-MAY-07:03 | 19.27 |
June | 560439.80 | 815.27 | 25-JUN-07:04 | 21.97 |
July | 603102.85 | 917.27 | 30-JUL-07:07 | 21.78 |
August | 124716.11 | 780.78 | 27-AUG-07:04 | 21.38 |
September | 116782.55 | 432.16 | 10-SEP-07:05 | 22.33 |
October | 4251656.47 | 9608.84 | 31-OCT-04:02 | 8.80 |
November | 0.106804E+09 | 30633.15 | 25-NOV-05:01 | 1.52 |
December | 0.655628E+09 | 33019.12 | 24-DEC-07:01 | 13.30 |
Annual Sum or Average | 0.341435E+10 | |||
Minimum of Months | 64545.76 | 311.98 | 0.92 | |
Maximum of Months | 0.159099E+10 | 33497.16 | 22.33 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.249864E+10 | 29029.58 | 01-JAN-07:01 | 11.10 |
February | 0.151620E+10 | 29012.39 | 11-FEB-05:01 | 11.78 |
March | 0.239084E+09 | 27342.24 | 22-MAR-04:01 | 6.60 |
April | 76075318.47 | 25346.50 | 06-APR-04:02 | 0.92 |
May | 167332.09 | 216.87 | 31-MAY-05:10 | 19.90 |
June | 1787314.81 | 510.18 | 24-JUN-05:10 | 21.20 |
July | 1166492.09 | 630.45 | 30-JUL-07:07 | 21.78 |
August | 53956.26 | 359.71 | 13-AUG-07:05 | 23.07 |
September | 719036.84 | 744.24 | 03-SEP-07:05 | 21.78 |
October | 48827554.26 | 26521.32 | 31-OCT-04:02 | 8.80 |
November | 0.206580E+09 | 27564.53 | 24-NOV-05:01 | 8.90 |
December | 0.112498E+10 | 28764.19 | 24-DEC-07:01 | 13.30 |
Annual Sum or Average | 0.571429E+10 | |||
Minimum of Months | 53956.26 | 216.87 | 0.92 | |
Maximum of Months | 0.249864E+10 | 29029.58 | 23.07 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.196969E+11 | 48242.45 | 07-JAN-18:00 | -5.0 |
February | 0.122473E+11 | 48320.25 | 11-FEB-18:00 | -5.0 |
March | 0.595045E+10 | 29324.37 | 22-MAR-11:10 | 4.40 |
April | 0.209793E+10 | 22499.07 | 05-APR-11:05 | 8.17 |
May | 0.340688E+09 | 6399.54 | 10-MAY-11:05 | 17.30 |
June | 23691376.38 | 2385.48 | 07-JUN-07:10 | 14.68 |
July | 94721406.56 | 3322.68 | 28-JUL-11:10 | 19.40 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 25.13 |
September | 0.288408E+09 | 6121.12 | 30-SEP-11:10 | 17.80 |
October | 0.316055E+10 | 20396.01 | 25-OCT-11:10 | 9.18 |
November | 0.614177E+10 | 29750.63 | 20-NOV-12:10 | 3.98 |
December | 0.129641E+11 | 35803.47 | 17-DEC-18:00 | 1.10 |
Annual Sum or Average | 0.630066E+11 | |||
Minimum of Months | 0.00 | 0.00 | -5.0 | |
Maximum of Months | 0.196969E+11 | 48320.25 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.368607E+10 | 3087.68 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.335384E+10 | 3087.68 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.382564E+10 | 3087.68 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.360950E+10 | 3087.68 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.375586E+10 | 3087.68 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.369163E+10 | 3087.68 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.367372E+10 | 3087.68 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.382564E+10 | 3087.68 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.360950E+10 | 3087.68 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.368607E+10 | 3087.68 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.356442E+10 | 3087.68 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.367372E+10 | 3087.68 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.439556E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.335384E+10 | 3087.68 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.382564E+10 | 3087.68 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.314662E+11 | 26358.01 | 02-JAN-09:09 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.286301E+11 | 26358.01 | 01-FEB-09:09 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.326576E+11 | 26358.01 | 01-MAR-09:09 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.308125E+11 | 26358.01 | 01-APR-09:09 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.320619E+11 | 26358.01 | 01-MAY-08:09 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.315136E+11 | 26358.01 | 01-JUN-08:09 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.313608E+11 | 26358.01 | 01-JUL-09:09 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.326576E+11 | 26358.01 | 01-AUG-08:09 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.308125E+11 | 26358.01 | 01-SEP-08:09 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.314662E+11 | 26358.01 | 02-OCT-08:09 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.304277E+11 | 26358.01 | 01-NOV-08:09 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.313608E+11 | 26358.01 | 01-DEC-09:09 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.375227E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.286301E+11 | 26358.01 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.326576E+11 | 26358.01 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.296499E+10 | 2483.66 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.269775E+10 | 2483.66 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.307725E+10 | 2483.66 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.290340E+10 | 2483.66 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.302112E+10 | 2483.66 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.296946E+10 | 2483.66 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.295506E+10 | 2483.66 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.307725E+10 | 2483.66 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.290340E+10 | 2483.66 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.296499E+10 | 2483.66 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.286713E+10 | 2483.66 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.295506E+10 | 2483.66 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.353568E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.269775E+10 | 2483.66 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.307725E+10 | 2483.66 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.296499E+10 | 2483.66 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.269775E+10 | 2483.66 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.307725E+10 | 2483.66 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.290340E+10 | 2483.66 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.302112E+10 | 2483.66 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.296946E+10 | 2483.66 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.295506E+10 | 2483.66 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.307725E+10 | 2483.66 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.290340E+10 | 2483.66 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.296499E+10 | 2483.66 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.286713E+10 | 2483.66 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.295506E+10 | 2483.66 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.353568E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.269775E+10 | 2483.66 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.307725E+10 | 2483.66 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.180413E+09 | 151.13 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.164152E+09 | 151.13 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.187244E+09 | 151.13 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.176665E+09 | 151.13 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.183829E+09 | 151.13 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.180685E+09 | 151.13 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.179809E+09 | 151.13 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.187244E+09 | 151.13 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.176665E+09 | 151.13 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.180413E+09 | 151.13 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.174459E+09 | 151.13 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.179809E+09 | 151.13 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.215139E+10 | ||||
Minimum of Months | 0.164152E+09 | 151.13 | 0.00 | 0.00 | |
Maximum of Months | 0.187244E+09 | 151.13 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.368607E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.384118E+10 |
February | 0.479114E+10 | 0.335384E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 875167.31 | 0.331352E+10 |
March | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8715347.83 | 0.218141E+10 |
April | 0.518069E+10 | 0.360950E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22395383.87 | 0.137010E+10 |
May | 0.536353E+10 | 0.375586E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 69361992.65 | 0.866081E+09 |
June | 0.528933E+10 | 0.369163E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.285212E+09 | 0.345760E+09 |
July | 0.525489E+10 | 0.367372E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326287E+09 | 0.195274E+09 |
August | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343350E+09 | 77629208.13 |
September | 0.518069E+10 | 0.360950E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89315872.63 | 0.423491E+09 |
October | 0.524694E+10 | 0.368607E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15287617.37 | 0.161148E+10 |
November | 0.504819E+10 | 0.356442E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96875.89 | 0.227110E+10 |
December | 0.525489E+10 | 0.367372E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342191E+10 |
Annual Sum or Average | 0.628175E+11 | 0.439556E+11 | 0.499918E+11 | 0.116090E+10 | 0.199189E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.335384E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77629208.13 |
Maximum of Months | 0.548013E+10 | 0.382564E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343350E+09 | 0.384118E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.314662E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343166E+10 |
February | 0.201852E+11 | 0.286301E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 716440.82 | 0.301756E+10 |
March | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7142162.92 | 0.205608E+10 |
April | 0.218263E+11 | 0.308125E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18325288.02 | 0.124255E+10 |
May | 0.225967E+11 | 0.320619E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56777165.37 | 0.735597E+09 |
June | 0.222841E+11 | 0.315136E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.233500E+09 | 0.281933E+09 |
July | 0.221389E+11 | 0.313608E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.267590E+09 | 0.158391E+09 |
August | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281662E+09 | 63580898.66 |
September | 0.218263E+11 | 0.308125E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 73110785.72 | 0.351757E+09 |
October | 0.221054E+11 | 0.314662E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12512334.50 | 0.142822E+10 |
November | 0.212681E+11 | 0.304277E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79335.72 | 0.206546E+10 |
December | 0.221389E+11 | 0.313608E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.311021E+10 |
Annual Sum or Average | 0.264651E+12 | 0.375227E+12 | 0.842987E+11 | 0.951415E+09 | 0.179430E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.286301E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63580898.66 |
Maximum of Months | 0.230879E+11 | 0.326576E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281662E+09 | 0.343166E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.296499E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178900E+10 |
February | 0.190200E+10 | 0.269775E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 379433.69 | 0.154352E+10 |
March | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3785602.23 | 0.104502E+10 |
April | 0.205665E+10 | 0.290340E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9698036.23 | 0.625785E+09 |
May | 0.212923E+10 | 0.302112E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30020486.69 | 0.382360E+09 |
June | 0.209978E+10 | 0.296946E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123117E+09 | 0.149192E+09 |
July | 0.208610E+10 | 0.295506E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140515E+09 | 84128294.04 |
August | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147401E+09 | 33929614.25 |
September | 0.205665E+10 | 0.290340E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38512221.16 | 0.184567E+09 |
October | 0.208295E+10 | 0.296499E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6625190.33 | 0.740194E+09 |
November | 0.200405E+10 | 0.286713E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42033.76 | 0.109389E+10 |
December | 0.208610E+10 | 0.295506E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162108E+10 |
Annual Sum or Average | 0.249375E+11 | 0.353568E+11 | 0.529224E+11 | 0.500097E+09 | 0.929267E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.269775E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33929614.25 |
Maximum of Months | 0.217552E+10 | 0.307725E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147401E+09 | 0.178900E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.296499E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172707E+10 |
February | 0.190200E+10 | 0.269775E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 379361.19 | 0.148489E+10 |
March | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3786556.98 | 0.989758E+09 |
April | 0.205665E+10 | 0.290340E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9708130.57 | 0.591725E+09 |
May | 0.212923E+10 | 0.302112E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30064026.78 | 0.368020E+09 |
June | 0.209978E+10 | 0.296946E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123420E+09 | 0.148092E+09 |
July | 0.208610E+10 | 0.295506E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141021E+09 | 84123494.11 |
August | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148047E+09 | 33638882.79 |
September | 0.205665E+10 | 0.290340E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 38611169.88 | 0.181315E+09 |
October | 0.208295E+10 | 0.296499E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6625232.92 | 0.713383E+09 |
November | 0.200405E+10 | 0.286713E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42019.33 | 0.104546E+10 |
December | 0.208610E+10 | 0.295506E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154814E+10 |
Annual Sum or Average | 0.249375E+11 | 0.353568E+11 | 0.794328E+10 | 0.501705E+09 | 0.891562E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.269775E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33638882.79 |
Maximum of Months | 0.217552E+10 | 0.307725E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148047E+09 | 0.172707E+10 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.180413E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197672E+11 |
February | 0.00 | 0.164152E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124785E+11 |
March | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.654825E+10 |
April | 0.00 | 0.176665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3914691.38 | 0.247160E+10 |
May | 0.00 | 0.183829E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30308539.69 | 0.693106E+09 |
June | 0.00 | 0.180685E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189682E+09 | 0.167304E+09 |
July | 0.00 | 0.179809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240551E+09 | 0.236125E+09 |
August | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169834E+09 | 0.127870E+09 |
September | 0.00 | 0.176665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11821610.40 | 0.663481E+09 |
October | 0.00 | 0.180413E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.397473E+10 |
November | 0.00 | 0.174459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.695440E+10 |
December | 0.00 | 0.179809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134406E+11 |
Annual Sum or Average | 0.00 | 0.215139E+10 | 0.646111E+09 | 0.675233E+11 | |||||
Minimum of Months | 0.00 | 0.164152E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127870E+09 |
Maximum of Months | 0.00 | 0.187244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240551E+09 | 0.197672E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 3087.68 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8485.95 | 07-JAN-05:10 |
February | 5888.82 | 01-FEB-15:09 | 3087.68 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 104.03 | 28-FEB-15:00 | 9601.35 | 12-FEB-00:55 |
March | 5888.82 | 01-MAR-15:09 | 3087.68 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 243.35 | 30-MAR-16:00 | 6296.11 | 22-MAR-05:00 |
April | 5888.82 | 01-APR-10:09 | 3087.68 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 189.13 | 04-APR-15:00 | 3040.36 | 05-APR-04:53 |
May | 5888.82 | 01-MAY-14:09 | 3087.68 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 594.80 | 29-MAY-18:03 | 2549.72 | 10-MAY-04:00 |
June | 5888.82 | 01-JUN-14:09 | 3087.68 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 963.04 | 11-JUN-18:10 | 1798.20 | 07-JUN-02:55 |
July | 5888.82 | 01-JUL-10:09 | 3087.68 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1047.82 | 09-JUL-19:27 | 1338.62 | 28-JUL-22:00 |
August | 5888.82 | 01-AUG-14:09 | 3087.68 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1323.76 | 18-AUG-20:10 | 737.24 | 25-AUG-05:00 |
September | 5888.82 | 01-SEP-14:09 | 3087.68 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 509.48 | 03-SEP-18:20 | 1778.32 | 29-SEP-05:00 |
October | 5888.82 | 02-OCT-14:09 | 3087.68 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 192.49 | 11-OCT-14:00 | 3399.77 | 28-OCT-04:00 |
November | 5888.82 | 01-NOV-14:09 | 3087.68 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 35.88 | 19-NOV-14:55 | 5630.40 | 30-NOV-21:03 |
December | 5888.82 | 01-DEC-15:09 | 3087.68 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 8430.15 | 17-DEC-08:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 737.24 | |||||
Maximum of Months | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 1323.76 | 9601.35 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 26358.01 | 02-JAN-09:09 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 6244.45 | 26-JAN-02:00 |
February | 24809.68 | 01-FEB-15:09 | 26358.01 | 01-FEB-09:09 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 85.15 | 28-FEB-15:00 | 8813.55 | 12-FEB-00:55 |
March | 24809.68 | 01-MAR-15:09 | 26358.01 | 01-MAR-09:09 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 199.19 | 30-MAR-16:00 | 5572.93 | 22-MAR-03:00 |
April | 24809.68 | 01-APR-10:09 | 26358.01 | 01-APR-09:09 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 154.82 | 04-APR-15:00 | 2954.62 | 05-APR-04:53 |
May | 24809.68 | 01-MAY-14:09 | 26358.01 | 01-MAY-08:09 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 488.49 | 29-MAY-18:03 | 2358.65 | 10-MAY-04:00 |
June | 24809.68 | 01-JUN-14:09 | 26358.01 | 01-JUN-08:09 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 771.29 | 11-JUN-18:10 | 1420.91 | 07-JUN-02:55 |
July | 24809.68 | 01-JUL-10:09 | 26358.01 | 01-JUL-09:09 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 858.49 | 09-JUL-19:27 | 1096.49 | 28-JUL-20:15 |
August | 24809.68 | 01-AUG-14:09 | 26358.01 | 01-AUG-08:09 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1083.06 | 18-AUG-20:10 | 670.71 | 25-AUG-05:00 |
September | 24809.68 | 01-SEP-14:09 | 26358.01 | 01-SEP-08:09 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 418.50 | 03-SEP-18:03 | 1611.35 | 29-SEP-05:00 |
October | 24809.68 | 02-OCT-14:09 | 26358.01 | 02-OCT-08:09 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 157.55 | 11-OCT-14:00 | 3403.80 | 28-OCT-04:00 |
November | 24809.68 | 01-NOV-14:09 | 26358.01 | 01-NOV-08:09 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.38 | 19-NOV-15:00 | 4915.35 | 07-NOV-02:00 |
December | 24809.68 | 01-DEC-15:09 | 26358.01 | 01-DEC-09:09 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 8310.18 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 26358.01 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 670.71 | |||||
Maximum of Months | 24809.68 | 26358.01 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1083.06 | 8813.55 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2483.66 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 3697.92 | 07-JAN-05:06 |
February | 2337.76 | 01-FEB-15:09 | 2483.66 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.10 | 28-FEB-15:00 | 4163.97 | 12-FEB-07:10 |
March | 2337.76 | 01-MAR-15:09 | 2483.66 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 105.45 | 30-MAR-16:00 | 2728.29 | 22-MAR-05:00 |
April | 2337.76 | 01-APR-10:09 | 2483.66 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 81.97 | 04-APR-15:00 | 1363.68 | 05-APR-04:53 |
May | 2337.76 | 01-MAY-14:09 | 2483.66 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 264.18 | 29-MAY-18:10 | 1125.02 | 10-MAY-04:00 |
June | 2337.76 | 01-JUN-14:09 | 2483.66 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 417.49 | 11-JUN-18:10 | 790.47 | 07-JUN-03:00 |
July | 2337.76 | 01-JUL-10:09 | 2483.66 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 453.95 | 09-JUL-19:30 | 577.70 | 28-JUL-20:10 |
August | 2337.76 | 01-AUG-14:09 | 2483.66 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 573.61 | 18-AUG-20:10 | 337.55 | 25-AUG-04:45 |
September | 2337.76 | 01-SEP-14:09 | 2483.66 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 226.99 | 03-SEP-18:10 | 778.93 | 29-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 2483.66 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 83.42 | 11-OCT-14:00 | 1680.52 | 28-OCT-04:00 |
November | 2337.76 | 01-NOV-14:09 | 2483.66 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.56 | 19-NOV-15:00 | 2476.18 | 07-NOV-02:00 |
December | 2337.76 | 01-DEC-15:09 | 2483.66 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 3744.86 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 337.55 | |||||
Maximum of Months | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 573.61 | 4163.97 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2483.66 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 3677.21 | 07-JAN-05:10 |
February | 2337.76 | 01-FEB-15:09 | 2483.66 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.09 | 28-FEB-15:00 | 4163.73 | 12-FEB-07:10 |
March | 2337.76 | 01-MAR-15:09 | 2483.66 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 105.45 | 30-MAR-16:00 | 2728.29 | 22-MAR-05:00 |
April | 2337.76 | 01-APR-10:09 | 2483.66 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 81.96 | 04-APR-15:00 | 1278.42 | 05-APR-04:53 |
May | 2337.76 | 01-MAY-14:09 | 2483.66 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 265.35 | 29-MAY-18:10 | 1073.96 | 10-MAY-04:00 |
June | 2337.76 | 01-JUN-14:09 | 2483.66 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 417.51 | 11-JUN-18:10 | 773.66 | 07-JUN-02:55 |
July | 2337.76 | 01-JUL-10:09 | 2483.66 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 453.95 | 09-JUL-19:30 | 568.12 | 28-JUL-22:00 |
August | 2337.76 | 01-AUG-14:09 | 2483.66 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 573.62 | 18-AUG-20:10 | 319.47 | 25-AUG-05:00 |
September | 2337.76 | 01-SEP-14:09 | 2483.66 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 228.49 | 03-SEP-18:10 | 735.41 | 29-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 2483.66 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 83.42 | 11-OCT-14:00 | 1601.47 | 28-OCT-04:00 |
November | 2337.76 | 01-NOV-14:09 | 2483.66 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.56 | 19-NOV-15:00 | 2433.97 | 30-NOV-21:03 |
December | 2337.76 | 01-DEC-15:09 | 2483.66 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 3653.03 | 17-DEC-08:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 319.47 | |||||
Maximum of Months | 2337.76 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 573.62 | 4163.73 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 151.13 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47811.37 | 07-JAN-17:00 |
February | 0.00 | 01-FEB-00:10 | 151.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 48162.18 | 11-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 151.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 29251.14 | 22-MAR-11:10 |
April | 0.00 | 01-APR-00:10 | 151.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 197.20 | 16-APR-11:05 | 23043.46 | 05-APR-11:05 |
May | 0.00 | 01-MAY-00:10 | 151.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 433.92 | 30-MAY-11:05 | 7080.09 | 10-MAY-11:05 |
June | 0.00 | 01-JUN-00:10 | 151.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1453.68 | 06-JUN-11:02 | 2358.00 | 07-JUN-07:10 |
July | 0.00 | 01-JUL-00:10 | 151.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1868.04 | 08-JUL-11:02 | 4023.45 | 28-JUL-17:00 |
August | 0.00 | 01-AUG-00:10 | 151.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1627.95 | 01-AUG-11:02 | 1571.54 | 08-AUG-16:53 |
September | 0.00 | 01-SEP-00:10 | 151.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 334.14 | 09-SEP-11:05 | 6656.67 | 30-SEP-11:10 |
October | 0.00 | 01-OCT-00:10 | 151.13 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 21012.44 | 25-OCT-11:10 |
November | 0.00 | 01-NOV-00:10 | 151.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 30138.30 | 20-NOV-12:10 |
December | 0.00 | 01-DEC-00:10 | 151.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 35967.21 | 17-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1571.54 | ||||
Maximum of Months | 0.00 | 151.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1868.04 | 48162.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3204.73 | 03-JAN-15:30 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 840.27 |
February | 5426.23 | 28-FEB-16:00 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.01 |
March | 15619.71 | 30-MAR-21:20 | 0.00 | 514.61 | 1839.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.57 |
April | 13340.35 | 17-APR-20:33 | 0.00 | 2058.45 | 1839.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 347.28 |
May | 16402.67 | 19-MAY-21:40 | 0.00 | 343.08 | 1226.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.65 |
June | 30124.03 | 14-JUN-20:10 | 0.00 | 2744.61 | 2452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 477.96 | 0.00 |
July | 30429.51 | 24-JUL-20:10 | 0.00 | 2744.61 | 2452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 352.30 | 0.00 |
August | 30390.13 | 25-AUG-20:10 | 0.00 | 2744.61 | 2452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 157.79 | 0.00 |
September | 28303.63 | 08-SEP-20:10 | 0.00 | 2744.61 | 2452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 254.59 | 0.00 |
October | 14894.42 | 10-OCT-21:23 | 0.00 | 514.61 | 1839.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 335.89 |
November | 6978.43 | 04-NOV-16:00 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.45 |
December | 4713.37 | 13-DEC-15:50 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.02 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3204.73 | 0.00 | 343.08 | 1226.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 30429.51 | 5888.82 | 3087.68 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 477.96 | 840.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 63840.62 | 27-JAN-07:05 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1021.40 |
February | 66529.31 | 03-FEB-06:05 | 0.00 | 5857.33 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1164.99 |
March | 66499.57 | 29-MAR-20:20 | 0.00 | 11714.67 | 2067.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.16 |
April | 74167.52 | 09-APR-19:15 | 0.00 | 5857.33 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 606.62 |
May | 105791.28 | 19-MAY-20:43 | 0.00 | 17572.00 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 18.53 | 0.00 |
June | 130733.59 | 04-JUN-18:10 | 0.00 | 5857.33 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 441.34 | 0.00 |
July | 126212.46 | 24-JUL-20:10 | 0.00 | 23429.34 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 293.98 | 0.00 |
August | 121940.30 | 25-AUG-20:10 | 0.00 | 23429.34 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 129.43 | 0.00 |
September | 141099.89 | 24-SEP-07:01 | 0.00 | 11714.67 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.69 |
October | 68845.80 | 18-OCT-21:00 | 0.00 | 11714.67 | 2067.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.72 |
November | 55337.34 | 22-NOV-07:05 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 892.26 |
December | 59662.91 | 18-DEC-07:05 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 726.87 |
Annual Sum or Average | |||||||||||
Minimum of Months | 55337.34 | 0.00 | 5857.33 | 2067.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 141099.89 | 12404.84 | 23429.34 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 441.34 | 1164.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5658.15 | 28-JAN-15:20 | 2337.76 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.48 |
February | 9075.84 | 21-FEB-14:40 | 2045.54 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.09 |
March | 14838.60 | 30-MAR-20:43 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 | 0.00 |
April | 11622.14 | 16-APR-18:10 | 0.00 | 413.94 | 1460.44 | 0.00 | 0.00 | 0.00 | 0.00 | 56.59 | 0.00 |
May | 14546.74 | 19-MAY-20:43 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 8.45 | 0.00 |
June | 16910.82 | 13-JUN-20:08 | 0.00 | 2207.70 | 2596.34 | 0.00 | 0.00 | 0.00 | 0.00 | 242.11 | 0.00 |
July | 17380.60 | 02-JUL-18:43 | 0.00 | 413.94 | 1460.44 | 0.00 | 0.00 | 0.00 | 0.00 | 247.45 | 0.00 |
August | 17393.36 | 27-AUG-19:23 | 0.00 | 413.94 | 1460.44 | 0.00 | 0.00 | 0.00 | 0.00 | 281.27 | 0.00 |
September | 17449.05 | 08-SEP-21:23 | 0.00 | 413.94 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 17095.49 | 10-OCT-20:43 | 0.00 | 1655.77 | 1947.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.51 |
November | 18655.96 | 12-NOV-19:10 | 0.00 | 1379.81 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 500.92 |
December | 8491.98 | 12-DEC-14:00 | 2045.54 | 2483.66 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.03 |
Annual Sum or Average | |||||||||||
Minimum of Months | 5658.15 | 0.00 | 413.94 | 1460.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18655.96 | 2337.76 | 2483.66 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 281.27 | 500.92 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4547.80 | 26-JAN-14:00 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 504.43 |
February | 6948.90 | 21-FEB-14:40 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.09 |
March | 11336.90 | 30-MAR-20:43 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 3.45 | 0.00 |
April | 9601.43 | 16-APR-18:10 | 0.00 | 413.94 | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 57.44 | 0.00 |
May | 11444.70 | 19-MAY-20:43 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 9.42 | 0.00 |
June | 14463.54 | 04-JUN-18:43 | 0.00 | 413.94 | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 142.40 | 0.00 |
July | 14768.80 | 02-JUL-18:43 | 0.00 | 413.94 | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 244.43 | 0.00 |
August | 14805.47 | 27-AUG-19:23 | 0.00 | 413.94 | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 278.23 | 0.00 |
September | 14661.45 | 08-SEP-21:23 | 0.00 | 413.94 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 14177.93 | 10-OCT-20:43 | 0.00 | 1655.77 | 292.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.88 |
November | 7807.75 | 06-NOV-14:30 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.00 |
December | 6150.96 | 12-DEC-14:00 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.03 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4547.80 | 0.00 | 413.94 | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14805.47 | 2045.54 | 2483.66 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 278.23 | 504.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 80.66 | 01-JAN-07:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.01 |
February | 26.22 | 06-FEB-05:02 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.95 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.11 |
April | 0.00 | 01-APR-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.55 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.58 |
June | 0.00 | 01-JUN-00:05 | 0.00 | 16.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.85 |
July | 0.00 | 01-JUL-00:05 | 0.00 | 16.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.86 |
August | 0.00 | 01-AUG-00:05 | 0.00 | 16.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.83 |
September | 0.00 | 01-SEP-00:05 | 0.00 | 16.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.92 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.01 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.68 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240.54 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 8.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.83 | |
Maximum of Months | 80.66 | 0.00 | 83.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240.54 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.108114E+12 | 81718.11 | 31-JAN-15:39 | 0.108237E+12 | 234010.75 | 08-JAN-08:09 |
February | 0.100071E+12 | 91634.02 | 28-FEB-15:09 | 0.634403E+11 | 279821.17 | 12-FEB-08:09 |
March | 0.120124E+12 | 109497.76 | 30-MAR-14:09 | 0.177039E+11 | 88103.12 | 19-MAR-08:09 |
April | 0.125947E+12 | 107795.85 | 17-APR-14:30 | 0.104036E+11 | 86269.49 | 06-APR-06:10 |
May | 0.148727E+12 | 121191.57 | 30-MAY-14:00 | 0.787607E+10 | 8174.17 | 10-MAY-11:20 |
June | 0.170115E+12 | 131160.76 | 23-JUN-13:39 | 0.743567E+10 | 4904.28 | 01-JUN-11:20 |
July | 0.183743E+12 | 141062.85 | 08-JUL-14:50 | 0.751750E+10 | 4865.89 | 03-JUL-11:39 |
August | 0.192896E+12 | 136303.82 | 01-AUG-14:00 | 0.757252E+10 | 4864.16 | 31-AUG-11:09 |
September | 0.155607E+12 | 128904.50 | 07-SEP-15:00 | 0.744860E+10 | 8022.19 | 28-SEP-16:49 |
October | 0.128643E+12 | 117373.95 | 10-OCT-14:09 | 0.104841E+11 | 82318.57 | 26-OCT-06:10 |
November | 0.111290E+12 | 96757.21 | 04-NOV-15:39 | 0.206577E+11 | 149622.54 | 22-NOV-07:10 |
December | 0.109281E+12 | 92612.08 | 12-DEC-17:49 | 0.549636E+11 | 180041.36 | 18-DEC-07:10 |
Annual Sum or Average | 0.165456E+13 | 0.323741E+12 | ||||
Minimum of Months | 0.100071E+12 | 81718.11 | 0.743567E+10 | 4864.16 | ||
Maximum of Months | 0.192896E+12 | 141062.85 | 0.108237E+12 | 279821.17 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.412627E+11 | 0.113952E+11 | 0.164409E+11 | 0.00 | 0.383696E+11 | 0.00 | 0.00 | 0.645599E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.375436E+11 | 0.972591E+10 | 0.149157E+11 | 0.00 | 0.342016E+11 | 0.00 | 0.00 | 0.368448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.428250E+11 | 0.994556E+10 | 0.168545E+11 | 0.00 | 0.373023E+11 | 0.00 | 0.00 | 0.131968E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.404055E+11 | 0.880340E+10 | 0.160165E+11 | 0.00 | 0.346241E+11 | 0.00 | 0.00 | 0.260974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.420438E+11 | 0.838168E+10 | 0.166477E+11 | 0.00 | 0.353389E+11 | 0.00 | 0.00 | 0.463152E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.413249E+11 | 0.779742E+10 | 0.162772E+11 | 0.00 | 0.351415E+11 | 0.00 | 0.00 | 0.695743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.411244E+11 | 0.817521E+10 | 0.163871E+11 | 0.00 | 0.364426E+11 | 0.00 | 0.00 | 0.816138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.428250E+11 | 0.877265E+10 | 0.168545E+11 | 0.00 | 0.372474E+11 | 0.00 | 0.00 | 0.871969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.404055E+11 | 0.926905E+10 | 0.160165E+11 | 0.00 | 0.348738E+11 | 0.00 | 0.00 | 0.550424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.412627E+11 | 0.104288E+11 | 0.164409E+11 | 0.00 | 0.359446E+11 | 0.00 | 0.00 | 0.245656E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.399008E+11 | 0.108373E+11 | 0.159174E+11 | 0.00 | 0.354516E+11 | 0.00 | 0.00 | 0.918329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.411244E+11 | 0.115973E+11 | 0.163871E+11 | 0.00 | 0.379273E+11 | 0.00 | 0.00 | 0.224519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.492048E+12 | 0.115129E+12 | 0.195156E+12 | 0.432865E+12 | 0.00 | 0.419361E+12 | |||||||
Minimum of Months | 0.375436E+11 | 0.779742E+10 | 0.149157E+11 | 0.00 | 0.342016E+11 | 0.00 | 0.00 | 0.645599E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.428250E+11 | 0.115973E+11 | 0.168545E+11 | 0.00 | 0.383696E+11 | 0.00 | 0.00 | 0.871969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.999371E+11 | 0.00 | 0.830017E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.559324E+11 | 0.00 | 0.750791E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.944558E+10 | 0.00 | 0.825835E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.263043E+10 | 0.00 | 0.777312E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 44884278.55 | 0.00 | 0.783118E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.743567E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.751750E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.757252E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 62411780.26 | 0.00 | 0.738619E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.270580E+10 | 0.00 | 0.777829E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.129355E+11 | 0.00 | 0.772212E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.467750E+11 | 0.00 | 0.818861E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.230469E+12 | 0.932716E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.738619E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.999371E+11 | 0.00 | 0.830017E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 34564.13 | 02-JAN-09:09 | 7321.52 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 23925.31 | 01-JAN-08:50 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 34564.13 | 01-FEB-09:09 | 7321.52 | 01-FEB-00:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 23925.31 | 01-FEB-08:20 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 34564.13 | 01-MAR-09:09 | 7321.52 | 01-MAR-00:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 23925.31 | 01-MAR-14:30 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 34564.13 | 01-APR-09:09 | 7321.52 | 01-APR-00:10 | 10771.04 | 01-APR-09:09 | 0.00 | 23925.31 | 01-APR-09:30 | 0.00 | 0.00 | 01-APR-00:10 |
May | 34564.13 | 01-MAY-08:09 | 7321.52 | 01-MAY-00:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 23925.31 | 01-MAY-08:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 34564.13 | 01-JUN-08:09 | 7321.52 | 01-JUN-00:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 23925.31 | 07-JUN-07:19 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 34564.13 | 01-JUL-09:09 | 7321.52 | 01-JUL-00:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 23925.31 | 28-JUL-11:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 34564.13 | 01-AUG-08:09 | 7321.52 | 01-AUG-00:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 20936.86 | 01-AUG-05:10 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 34564.13 | 01-SEP-08:09 | 7321.52 | 01-SEP-00:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 23925.31 | 14-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 34564.13 | 02-OCT-08:09 | 7321.52 | 01-OCT-00:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 23925.31 | 01-OCT-11:09 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 34564.13 | 01-NOV-08:09 | 7321.52 | 01-NOV-00:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 23925.31 | 01-NOV-11:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 34564.13 | 01-DEC-09:09 | 7321.52 | 01-DEC-00:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 23925.31 | 01-DEC-07:49 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 34564.13 | 7321.52 | 10771.04 | 0.00 | 20936.86 | 0.00 | 0.00 | |||||
Maximum of Months | 34564.13 | 7321.52 | 10771.04 | 0.00 | 23925.31 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 13061.30 | 31-JAN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 25362.00 | 28-FEB-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 43225.74 | 30-MAR-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 41523.82 | 17-APR-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 54919.55 | 30-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 64888.73 | 23-JUN-13:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 74790.82 | 08-JUL-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 70031.79 | 01-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 62632.48 | 07-SEP-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 51101.92 | 10-OCT-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 29225.72 | 02-NOV-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 24616.73 | 12-DEC-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 13061.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 74790.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 81718.11 | 31-JAN-15:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 23925.31 | 0.00 | 0.00 | 12457.64 | 0.00 |
February | 91634.02 | 28-FEB-15:09 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 25362.00 | 0.00 |
March | 109497.76 | 30-MAR-14:09 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 43225.74 | 0.00 |
April | 107795.85 | 17-APR-14:30 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 41523.82 | 0.00 |
May | 121191.57 | 30-MAY-14:00 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 54919.55 | 0.00 |
June | 131160.76 | 23-JUN-13:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 64888.73 | 0.00 |
July | 141062.85 | 08-JUL-14:50 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 74790.82 | 0.00 |
August | 136303.82 | 01-AUG-14:00 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 70031.79 | 0.00 |
September | 128904.50 | 07-SEP-15:00 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 62632.48 | 0.00 |
October | 117373.95 | 10-OCT-14:09 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 51101.92 | 0.00 |
November | 96757.21 | 04-NOV-15:39 | 34564.13 | 10771.04 | 0.00 | 0.00 | 23925.31 | 0.00 | 0.00 | 27496.74 | 0.00 |
December | 92612.08 | 12-DEC-17:49 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 23925.31 | 0.00 | 0.00 | 16030.09 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 81718.11 | 34564.13 | 10771.04 | 0.00 | 0.00 | 20936.86 | 0.00 | 0.00 | 12457.64 | 0.00 | |
Maximum of Months | 141062.85 | 34564.13 | 10771.04 | 7321.52 | 0.00 | 23925.31 | 0.00 | 0.00 | 74790.82 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 232148.75 | 08-JAN-08:09 | 0.00 | 5062.45 | 24-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 277959.17 | 12-FEB-08:09 | 0.00 | 5063.07 | 01-FEB-12:09 | 0.00 |
March | 0.00 | 0.00 | 86241.12 | 19-MAR-08:09 | 0.00 | 5046.33 | 01-MAR-12:09 | 0.00 |
April | 0.00 | 0.00 | 84407.49 | 06-APR-06:10 | 0.00 | 5004.38 | 03-APR-11:20 | 0.00 |
May | 0.00 | 0.00 | 3233.65 | 10-MAY-11:20 | 0.00 | 4956.19 | 01-MAY-11:00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4904.28 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4865.89 | 03-JUL-11:39 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4864.16 | 31-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 3661.52 | 28-SEP-16:00 | 0.00 | 4896.34 | 29-SEP-11:30 | 0.00 |
October | 0.00 | 0.00 | 78816.53 | 26-OCT-06:10 | 0.00 | 4950.04 | 31-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 147760.54 | 22-NOV-07:10 | 0.00 | 5004.56 | 30-NOV-12:50 | 0.00 |
December | 0.00 | 0.00 | 175477.64 | 18-DEC-07:10 | 0.00 | 5044.04 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4864.16 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 277959.17 | 0.00 | 5063.07 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 9.33 | 19.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6.83 | 18.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.83 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 24.48 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 24.51 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 24.47 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.45 | 0.00 | 0.00 |
November | 1.50 | 20.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6.50 | 20.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 25.00 | 19.50 | 0.00 | 19.00 | 24.50 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 9.33 | 20.47 | 0.00 | 0.00 | 7.33 | 24.51 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.47 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 24.50 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 24.49 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 24.48 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 24.47 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.46 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 24.48 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.48 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.45 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 28.17 | 24.48 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 24.50 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.83 | 19.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4.50 | 19.05 | 0.00 | 0.00 | 0.33 | 24.46 | 0.00 | 0.00 |
March | 0.17 | 20.42 | 0.00 | 0.00 | 1.17 | 24.50 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 24.48 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 24.50 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 17.67 | 24.56 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 31.50 | 24.61 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 42.67 | 24.62 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 20.33 | 24.56 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 8.83 | 24.51 | 0.00 | 0.00 |
November | 0.33 | 20.17 | 0.00 | 0.00 | 1.00 | 24.48 | 0.00 | 0.00 |
December | 2.50 | 20.14 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
Annual Sum or Average | 13.33 | 19.70 | 0.00 | 130.83 | 24.58 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 5.83 | 20.42 | 0.00 | 0.00 | 42.67 | 24.62 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.17 | 19.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6.00 | 18.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.50 | 20.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.17 | 20.50 | 0.00 | 0.00 | 0.17 | 24.47 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.47 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 24.52 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.33 | 24.56 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 22.83 | 24.57 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.83 | 24.54 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 24.50 | 0.00 | 0.00 |
November | 0.67 | 20.18 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
December | 4.83 | 20.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 20.33 | 19.62 | 0.00 | 56.00 | 24.55 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 8.17 | 20.50 | 0.00 | 0.00 | 22.83 | 24.57 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.34 | 332.33 | 21.16 | 332.33 | 21.16 |
February | 376.00 | 22.02 | 185.67 | 21.20 | 185.67 | 21.20 |
March | 351.50 | 22.91 | 53.33 | 22.28 | 31.00 | 21.12 |
April | 189.83 | 23.29 | 77.83 | 23.72 | 5.17 | 21.29 |
May | 42.83 | 23.47 | 279.83 | 23.89 | 5.83 | 23.89 |
June | 13.33 | 23.80 | 360.67 | 23.89 | 5.00 | 23.89 |
July | 22.17 | 23.89 | 413.17 | 23.89 | 22.17 | 23.89 |
August | 26.67 | 23.89 | 420.17 | 23.89 | 26.67 | 23.89 |
September | 29.33 | 23.78 | 335.33 | 23.89 | 14.83 | 23.89 |
October | 221.17 | 23.20 | 107.00 | 23.84 | 23.83 | 23.66 |
November | 353.00 | 22.71 | 55.50 | 21.77 | 42.50 | 21.12 |
December | 404.17 | 21.69 | 182.67 | 21.12 | 182.67 | 21.12 |
Annual Sum or Average | 2444.00 | 22.38 | 2803.50 | 23.13 | 877.67 | 21.46 |
Minimum of Months | 13.33 | 21.34 | 53.33 | 21.12 | 5.00 | 21.12 |
Maximum of Months | 414.00 | 23.89 | 420.17 | 23.89 | 332.33 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 408.00 | 21.44 | 169.00 | 21.11 | 169.00 | 21.11 |
February | 327.83 | 21.99 | 83.17 | 21.23 | 79.67 | 21.11 |
March | 219.50 | 22.72 | 81.33 | 23.82 | 2.17 | 21.20 |
April | 80.50 | 22.86 | 206.50 | 23.89 | 0.33 | 21.25 |
May | 14.33 | 22.95 | 357.00 | 23.89 | 0.00 | 0.00 |
June | 27.50 | 23.79 | 377.50 | 23.89 | 21.67 | 23.89 |
July | 49.50 | 23.89 | 414.17 | 23.89 | 49.50 | 23.89 |
August | 83.83 | 23.89 | 421.00 | 23.89 | 83.83 | 23.89 |
September | 43.33 | 23.78 | 375.50 | 23.89 | 34.33 | 23.89 |
October | 127.33 | 22.77 | 180.33 | 23.89 | 19.83 | 23.87 |
November | 265.50 | 22.56 | 60.50 | 23.53 | 7.83 | 21.13 |
December | 381.67 | 21.89 | 72.00 | 21.69 | 57.17 | 21.12 |
Annual Sum or Average | 2028.83 | 22.29 | 2798.00 | 23.58 | 525.33 | 22.22 |
Minimum of Months | 14.33 | 21.44 | 60.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 408.00 | 23.89 | 421.00 | 23.89 | 169.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 379.67 | 21.86 | 123.00 | 21.12 | 122.50 | 21.11 |
February | 279.67 | 22.02 | 87.83 | 21.64 | 71.17 | 21.11 |
March | 187.00 | 22.70 | 106.50 | 23.64 | 9.67 | 21.11 |
April | 108.50 | 23.02 | 198.17 | 23.84 | 3.50 | 21.11 |
May | 26.67 | 23.18 | 346.00 | 23.89 | 3.17 | 23.89 |
June | 20.50 | 23.74 | 375.67 | 23.89 | 13.17 | 23.89 |
July | 21.17 | 23.89 | 414.17 | 23.89 | 21.17 | 23.89 |
August | 28.83 | 23.89 | 421.17 | 23.89 | 28.83 | 23.89 |
September | 17.00 | 23.69 | 374.33 | 23.89 | 9.50 | 23.89 |
October | 96.33 | 22.79 | 245.67 | 23.89 | 10.50 | 23.89 |
November | 173.50 | 22.71 | 122.33 | 23.75 | 6.17 | 21.11 |
December | 322.50 | 22.38 | 71.83 | 22.27 | 41.83 | 21.11 |
Annual Sum or Average | 1661.33 | 22.43 | 2886.67 | 23.64 | 341.17 | 21.81 |
Minimum of Months | 17.00 | 21.86 | 71.83 | 21.12 | 3.17 | 21.11 |
Maximum of Months | 379.67 | 23.89 | 421.17 | 23.89 | 122.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 402.67 | 21.51 | 171.83 | 21.19 | 171.83 | 21.19 |
February | 308.83 | 21.72 | 117.00 | 21.37 | 107.00 | 21.14 |
March | 246.50 | 22.42 | 94.50 | 23.35 | 18.33 | 21.11 |
April | 157.17 | 22.73 | 164.83 | 23.79 | 11.17 | 22.46 |
May | 65.00 | 23.14 | 317.17 | 23.89 | 20.50 | 23.82 |
June | 52.17 | 23.72 | 368.50 | 23.89 | 40.00 | 23.89 |
July | 74.83 | 23.88 | 414.17 | 23.89 | 74.83 | 23.88 |
August | 77.00 | 23.89 | 421.00 | 23.89 | 77.00 | 23.89 |
September | 54.00 | 23.61 | 367.67 | 23.89 | 34.67 | 23.89 |
October | 152.17 | 22.48 | 217.33 | 23.87 | 30.50 | 23.72 |
November | 217.00 | 22.30 | 93.67 | 23.64 | 8.33 | 21.11 |
December | 351.17 | 21.82 | 91.50 | 21.86 | 66.67 | 21.11 |
Annual Sum or Average | 2158.50 | 22.25 | 2839.17 | 23.52 | 660.83 | 22.31 |
Minimum of Months | 52.17 | 21.51 | 91.50 | 21.19 | 8.33 | 21.11 |
Maximum of Months | 402.67 | 23.89 | 421.00 | 23.89 | 171.83 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.33543 | 28.36666 | -0.5897 | 13.57207 |
February | 376.00000 | 22.01308 | 30.66591 | -0.3712 | 10.72392 |
March | 422.00000 | 23.05472 | 36.56153 | 0.00457 | 7.07791 |
April | 405.00000 | 23.58825 | 42.51887 | 0.23894 | 7.30523 |
May | 418.00000 | 23.84090 | 49.02014 | -0.4816 | 10.35197 |
June | 408.00000 | 23.88573 | 50.56825 | -0.3655 | 8.00452 |
July | 415.00000 | 23.88945 | 55.12174 | -0.3128 | 7.13870 |
August | 422.00000 | 23.88942 | 55.59781 | -0.3048 | 7.02124 |
September | 405.00000 | 23.88018 | 52.64586 | -0.4197 | 8.89483 |
October | 414.00000 | 23.50362 | 46.67704 | 0.24475 | 7.40645 |
November | 399.00000 | 22.83191 | 36.92914 | -0.0563 | 7.32502 |
December | 415.00000 | 21.73960 | 32.76229 | -0.4071 | 10.24499 |
Annual Sum or Average | 4913.00000 | 23.12890 | 43.22416 | -0.2349 | 8.74375 |
Minimum of Months | 376.00000 | 21.33543 | 28.36666 | -0.5897 | 7.02124 |
Maximum of Months | 422.00000 | 23.88945 | 55.59781 | 0.24475 | 13.57207 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.45508 | 26.10178 | -0.4369 | 10.43917 |
February | 376.00000 | 22.21147 | 28.28225 | -0.1983 | 8.72562 |
March | 422.00000 | 23.25591 | 33.84729 | 0.17338 | 7.30858 |
April | 405.00000 | 23.66581 | 40.02367 | 0.36043 | 8.54244 |
May | 418.00000 | 23.84994 | 47.73484 | -0.3700 | 8.31000 |
June | 408.00000 | 23.88131 | 51.21718 | -0.2874 | 7.01586 |
July | 415.00000 | 23.88955 | 57.37614 | -0.2371 | 6.31472 |
August | 422.00000 | 23.88954 | 58.19009 | -0.2298 | 6.23141 |
September | 405.00000 | 23.87500 | 53.28929 | -0.3391 | 7.66025 |
October | 414.00000 | 23.52636 | 44.61470 | 0.33597 | 8.37161 |
November | 399.00000 | 22.98085 | 34.39324 | 0.08011 | 7.10473 |
December | 415.00000 | 22.03470 | 30.37892 | -0.2276 | 8.02210 |
Annual Sum or Average | 4913.00000 | 23.21677 | 42.24167 | -0.1149 | 7.82924 |
Minimum of Months | 376.00000 | 21.45508 | 26.10178 | -0.4369 | 6.23141 |
Maximum of Months | 422.00000 | 23.88955 | 58.19009 | 0.36043 | 10.43917 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.02598 | 24.96920 | -0.2920 | 9.39904 |
February | 376.00000 | 22.48258 | 27.36434 | -0.1233 | 8.80365 |
March | 422.00000 | 23.33684 | 32.87076 | 0.19388 | 7.88207 |
April | 405.00000 | 23.63758 | 39.66003 | 0.33331 | 8.49107 |
May | 418.00000 | 23.83666 | 46.87445 | -0.3852 | 8.78749 |
June | 408.00000 | 23.88022 | 49.42924 | -0.2717 | 6.93563 |
July | 415.00000 | 23.88941 | 54.50229 | -0.2108 | 6.12841 |
August | 422.00000 | 23.88935 | 54.54033 | -0.1847 | 5.89863 |
September | 405.00000 | 23.87918 | 50.37524 | -0.2949 | 7.22725 |
October | 414.00000 | 23.61808 | 42.50776 | 0.39531 | 9.51719 |
November | 399.00000 | 23.35653 | 32.66671 | 0.21720 | 7.85998 |
December | 415.00000 | 22.70658 | 28.65432 | -0.0459 | 7.66385 |
Annual Sum or Average | 4913.00000 | 23.38434 | 40.48054 | -0.0562 | 7.87415 |
Minimum of Months | 376.00000 | 22.02598 | 24.96920 | -0.3852 | 5.89863 |
Maximum of Months | 422.00000 | 23.88941 | 54.54033 | 0.39531 | 9.51719 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.56849 | 25.75311 | -0.4148 | 10.51722 |
February | 376.00000 | 22.09288 | 28.36031 | -0.2323 | 9.38276 |
March | 422.00000 | 23.01005 | 34.18050 | 0.09764 | 7.68856 |
April | 405.00000 | 23.41441 | 41.31423 | 0.26143 | 8.04027 |
May | 418.00000 | 23.75875 | 49.11008 | -0.4407 | 10.10583 |
June | 408.00000 | 23.86441 | 51.19841 | -0.3044 | 7.42678 |
July | 415.00000 | 23.88808 | 56.84951 | -0.2344 | 6.32249 |
August | 422.00000 | 23.88940 | 56.75916 | -0.2105 | 6.08659 |
September | 405.00000 | 23.84726 | 52.74495 | -0.3303 | 7.82644 |
October | 414.00000 | 23.35320 | 44.46890 | 0.32050 | 9.04084 |
November | 399.00000 | 23.00370 | 34.03072 | 0.11802 | 7.71366 |
December | 415.00000 | 22.13444 | 29.87879 | -0.1889 | 8.28466 |
Annual Sum or Average | 4913.00000 | 23.15952 | 42.17247 | -0.1300 | 8.19421 |
Minimum of Months | 376.00000 | 21.56849 | 25.75311 | -0.4407 | 6.08659 |
Maximum of Months | 422.00000 | 23.88940 | 56.84951 | 0.32050 | 10.51722 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 58788604.32 | 18886382.30 | 9.33 | 45500669.19 | 13287935.13 | 0.00 | 0.08 | 20-JAN-15:40 | 0.00 | 01-JAN-00:10 | 2825.72 | 20-JAN-15:30 | 2182.39 | 31-JAN-15:10 | 769.77 | 20-JAN-15:10 | 901.94 | 20-JAN-15:30 | 0.00 | 01-JAN-00:10 |
February | 0.707570E+09 | 0.227238E+09 | 64.83 | 0.680538E+09 | 27032151.73 | 0.00 | 0.24 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 8109.53 | 28-FEB-15:10 | 7845.53 | 28-FEB-15:10 | 1116.58 | 18-FEB-17:00 | 2643.86 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.393265E+10 | 0.123878E+10 | 205.05 | 0.323981E+10 | 0.692840E+09 | 0.00 | 0.58 | 30-MAR-21:20 | 0.00 | 01-MAR-00:10 | 19932.99 | 30-MAR-21:20 | 17457.13 | 30-MAR-21:20 | 3835.71 | 30-MAR-11:45 | 6175.51 | 30-MAR-21:20 | 0.00 | 01-MAR-00:10 |
April | 0.934744E+10 | 0.295371E+10 | 317.01 | 0.774099E+10 | 0.160645E+10 | 0.00 | 0.47 | 17-APR-20:33 | 0.00 | 01-APR-00:10 | 17250.30 | 19-APR-14:50 | 14575.56 | 17-APR-15:00 | 4903.08 | 04-APR-14:10 | 5399.24 | 19-APR-15:00 | 0.00 | 01-APR-00:10 |
May | 0.189391E+11 | 0.591467E+10 | 445.10 | 0.146698E+11 | 0.426933E+10 | 0.00 | 0.63 | 30-MAY-21:40 | 0.00 | 01-MAY-00:10 | 23429.39 | 30-MAY-21:40 | 18985.72 | 29-MAY-19:40 | 6576.94 | 30-MAY-21:40 | 7408.56 | 30-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.304710E+11 | 0.963441E+10 | 553.89 | 0.229271E+11 | 0.754386E+10 | 0.00 | 1.00 | 12-JUN-20:10 | 0.00 | 01-JUN-00:15 | 45130.73 | 28-JUN-20:43 | 34890.35 | 14-JUN-20:10 | 13762.93 | 22-JUN-20:43 | 12302.33 | 25-JUN-18:08 | 0.00 | 01-JUN-00:05 |
July | 0.365158E+11 | 0.115129E+11 | 606.40 | 0.260648E+11 | 0.104510E+11 | 0.00 | 1.00 | 02-JUL-18:08 | 0.00 | 01-JUL-00:05 | 46171.90 | 26-JUL-20:43 | 35545.07 | 24-JUL-20:10 | 17169.28 | 26-JUL-20:43 | 12664.16 | 09-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.391503E+11 | 0.122328E+11 | 630.84 | 0.272807E+11 | 0.118697E+11 | 0.00 | 1.00 | 01-AUG-20:08 | 0.00 | 01-AUG-00:35 | 46441.80 | 22-AUG-22:03 | 34616.50 | 25-AUG-20:10 | 18289.46 | 22-AUG-22:03 | 12585.31 | 06-AUG-18:08 | 0.00 | 01-AUG-00:05 |
September | 0.237564E+11 | 0.736064E+10 | 510.82 | 0.172021E+11 | 0.655435E+10 | 0.00 | 1.00 | 06-SEP-20:10 | 0.00 | 01-SEP-00:05 | 45125.31 | 06-SEP-20:10 | 32947.07 | 08-SEP-20:10 | 13253.98 | 06-SEP-20:10 | 11860.70 | 08-SEP-20:10 | 0.00 | 01-SEP-00:05 |
October | 0.918697E+10 | 0.283412E+10 | 307.03 | 0.693791E+10 | 0.224906E+10 | 0.00 | 0.70 | 18-OCT-21:00 | 0.00 | 01-OCT-00:10 | 27680.23 | 18-OCT-21:00 | 17078.75 | 18-OCT-21:00 | 10601.49 | 18-OCT-21:00 | 7858.09 | 18-OCT-21:00 | 0.00 | 01-OCT-00:10 |
November | 0.270253E+10 | 0.843137E+09 | 162.40 | 0.216182E+10 | 0.540706E+09 | 0.00 | 0.34 | 04-NOV-16:00 | 0.00 | 01-NOV-00:10 | 12653.77 | 04-NOV-16:00 | 8486.64 | 04-NOV-16:00 | 4167.13 | 04-NOV-16:00 | 3753.91 | 04-NOV-16:00 | 0.00 | 01-NOV-00:10 |
December | 0.478999E+09 | 0.149780E+09 | 31.17 | 0.332343E+09 | 0.146656E+09 | 0.00 | 0.23 | 13-DEC-13:00 | 0.00 | 01-DEC-00:10 | 8488.01 | 13-DEC-13:00 | 5600.28 | 12-DEC-15:10 | 2903.00 | 13-DEC-12:44 | 2589.15 | 13-DEC-13:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.175248E+12 | 0.549210E+11 | 3843.89 | 0.129283E+12 | 0.459642E+11 | 0.00 | ||||||||||||||
Minimum of Months | 58788604.32 | 18886382.30 | 9.33 | 45500669.19 | 13287935.13 | 0.00 | 0.08 | 0.00 | 2825.72 | 2182.39 | 769.77 | 901.94 | 0.00 | |||||||
Maximum of Months | 0.391503E+11 | 0.122328E+11 | 630.84 | 0.272807E+11 | 0.118697E+11 | 0.00 | 1.00 | 0.00 | 46441.80 | 35545.07 | 18289.46 | 12664.16 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.125539E+10 | 0.405866E+09 | 26.67 | 0.960516E+09 | 0.294875E+09 | 0.00 | 0.19 | 31-JAN-15:10 | 0.00 | 01-JAN-00:10 | 29861.31 | 31-JAN-15:10 | 25419.48 | 31-JAN-15:10 | 8222.93 | 19-JAN-16:00 | 9495.33 | 31-JAN-15:10 | 0.00 | 01-JAN-00:10 |
February | 0.780621E+10 | 0.251015E+10 | 103.74 | 0.730214E+10 | 0.504072E+09 | 0.00 | 0.34 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 54060.15 | 28-FEB-15:10 | 52023.36 | 28-FEB-15:10 | 9917.57 | 18-FEB-17:00 | 17549.64 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.300028E+11 | 0.949505E+10 | 271.50 | 0.249864E+11 | 0.501638E+10 | 0.00 | 0.57 | 29-MAR-20:20 | 0.00 | 01-MAR-00:10 | 94206.26 | 29-MAR-20:20 | 77461.45 | 29-MAR-20:20 | 22678.68 | 30-MAR-11:25 | 30059.77 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
April | 0.608525E+11 | 0.192851E+11 | 355.51 | 0.500483E+11 | 0.108043E+11 | 0.00 | 0.63 | 21-APR-22:33 | 0.00 | 01-APR-00:10 | 106830.09 | 21-APR-22:33 | 81930.14 | 17-APR-14:50 | 30352.14 | 04-APR-14:10 | 31858.47 | 21-APR-22:33 | 0.00 | 01-APR-00:10 |
May | 0.107094E+12 | 0.335922E+11 | 477.24 | 0.803004E+11 | 0.267933E+11 | 0.00 | 0.79 | 19-MAY-20:43 | 0.00 | 01-MAY-00:10 | 143348.18 | 19-MAY-20:43 | 121167.93 | 19-MAY-20:43 | 43685.46 | 29-MAY-07:02 | 41546.17 | 19-MAY-20:43 | 0.00 | 01-MAY-00:10 |
June | 0.155454E+12 | 0.490825E+11 | 538.98 | 0.110968E+12 | 0.444856E+11 | 0.00 | 1.00 | 11-JUN-18:10 | 0.00 | 01-JUN-00:05 | 214500.46 | 29-JUN-20:10 | 169271.20 | 04-JUN-18:10 | 77465.46 | 22-JUN-20:43 | 60537.62 | 11-JUN-18:10 | 0.00 | 01-JUN-00:05 |
July | 0.182270E+12 | 0.570917E+11 | 582.50 | 0.120571E+12 | 0.616991E+11 | 0.00 | 1.00 | 02-JUL-18:10 | 0.00 | 01-JUL-00:05 | 221901.97 | 26-JUL-20:43 | 159642.19 | 24-JUL-20:10 | 96684.01 | 26-JUL-20:43 | 61489.73 | 09-JUL-18:10 | 0.00 | 01-JUL-00:05 |
August | 0.195257E+12 | 0.605793E+11 | 608.83 | 0.125669E+12 | 0.695879E+11 | 0.00 | 1.00 | 01-AUG-20:10 | 0.00 | 01-AUG-00:35 | 224045.30 | 08-AUG-20:10 | 155785.00 | 13-AUG-18:10 | 101366.55 | 08-AUG-20:10 | 61038.20 | 06-AUG-18:10 | 0.00 | 01-AUG-00:05 |
September | 0.123941E+12 | 0.385048E+11 | 519.10 | 0.843951E+11 | 0.395457E+11 | 0.00 | 1.00 | 06-SEP-20:10 | 0.00 | 01-SEP-00:05 | 218509.78 | 06-SEP-20:10 | 144365.80 | 08-SEP-20:10 | 81377.92 | 06-SEP-20:10 | 57545.72 | 08-SEP-20:10 | 0.00 | 01-SEP-00:05 |
October | 0.541072E+11 | 0.168302E+11 | 337.10 | 0.399144E+11 | 0.141928E+11 | 0.00 | 0.76 | 18-OCT-21:00 | 0.00 | 01-OCT-00:10 | 147850.81 | 18-OCT-21:00 | 82909.59 | 18-OCT-21:00 | 64941.22 | 18-OCT-21:00 | 41306.42 | 18-OCT-21:00 | 0.00 | 01-OCT-00:10 |
November | 0.191617E+11 | 0.603621E+10 | 195.05 | 0.153484E+11 | 0.381322E+10 | 0.00 | 0.45 | 03-NOV-21:05 | 0.00 | 01-NOV-00:10 | 71917.42 | 03-NOV-20:20 | 51739.47 | 03-NOV-21:05 | 24515.25 | 04-NOV-16:00 | 22816.31 | 03-NOV-20:20 | 0.00 | 01-NOV-00:10 |
December | 0.401120E+10 | 0.126817E+10 | 54.33 | 0.286331E+10 | 0.114789E+10 | 0.00 | 0.34 | 13-DEC-21:55 | 0.00 | 01-DEC-00:10 | 52493.92 | 12-DEC-14:00 | 38376.23 | 12-DEC-15:10 | 18210.48 | 13-DEC-12:40 | 17189.25 | 13-DEC-21:55 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.941212E+12 | 0.294681E+12 | 4070.55 | 0.663327E+12 | 0.277885E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.125539E+10 | 0.405866E+09 | 26.67 | 0.960516E+09 | 0.294875E+09 | 0.00 | 0.19 | 0.00 | 29861.31 | 25419.48 | 8222.93 | 9495.33 | 0.00 | |||||||
Maximum of Months | 0.195257E+12 | 0.605793E+11 | 608.83 | 0.125669E+12 | 0.695879E+11 | 0.00 | 1.00 | 0.00 | 224045.30 | 169271.20 | 101366.55 | 61489.73 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.596783E+09 | 0.175503E+09 | 70.00 | 0.527148E+09 | 69635061.00 | 0.00 | 0.29 | 31-JAN-14:40 | 0.00 | 01-JAN-00:10 | 6029.47 | 31-JAN-14:40 | 5384.28 | 31-JAN-14:50 | 1221.77 | 19-JAN-16:00 | 1725.84 | 31-JAN-14:40 | 0.00 | 01-JAN-00:10 |
February | 0.215705E+10 | 0.621481E+09 | 146.25 | 0.207619E+10 | 80862410.19 | 0.00 | 0.48 | 21-FEB-14:50 | 0.00 | 01-FEB-00:10 | 10188.53 | 28-FEB-15:30 | 10150.70 | 21-FEB-14:50 | 1167.31 | 18-FEB-16:00 | 2914.04 | 28-FEB-15:30 | 0.00 | 01-FEB-00:10 |
March | 0.548444E+10 | 0.158293E+10 | 314.85 | 0.485337E+10 | 0.631068E+09 | 0.00 | 0.80 | 30-MAR-20:43 | 0.00 | 01-MAR-00:10 | 18936.03 | 30-MAR-20:43 | 16584.99 | 30-MAR-20:43 | 2800.36 | 30-MAR-11:25 | 5032.78 | 30-MAR-20:43 | 0.00 | 01-MAR-00:10 |
April | 0.803756E+10 | 0.235297E+10 | 363.02 | 0.689854E+10 | 0.113902E+10 | 0.00 | 0.64 | 16-APR-18:10 | 0.00 | 01-APR-00:10 | 13469.65 | 16-APR-18:10 | 13161.40 | 16-APR-18:10 | 3335.86 | 04-APR-14:10 | 3949.35 | 16-APR-18:10 | 0.00 | 01-APR-00:10 |
May | 0.135604E+11 | 0.395296E+10 | 485.72 | 0.106707E+11 | 0.288964E+10 | 0.00 | 0.82 | 30-MAY-20:10 | 0.00 | 01-MAY-00:10 | 20673.76 | 30-MAY-20:10 | 16281.92 | 19-MAY-20:43 | 6319.34 | 30-MAY-20:10 | 5533.03 | 29-MAY-18:10 | 0.00 | 01-MAY-00:10 |
June | 0.203751E+11 | 0.602650E+10 | 580.01 | 0.153340E+11 | 0.504104E+10 | 0.00 | 1.00 | 13-JUN-20:08 | 0.00 | 01-JUN-00:05 | 27453.45 | 25-JUN-19:23 | 20599.19 | 13-JUN-20:08 | 8468.07 | 22-JUN-20:43 | 7123.22 | 25-JUN-18:08 | 0.00 | 01-JUN-00:05 |
July | 0.242545E+11 | 0.713779E+10 | 624.36 | 0.171789E+11 | 0.707561E+10 | 0.00 | 1.00 | 02-JUL-18:08 | 0.00 | 01-JUL-00:10 | 28410.49 | 26-JUL-20:43 | 21325.32 | 16-JUL-18:08 | 10879.32 | 26-JUL-20:43 | 7331.84 | 09-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.269657E+11 | 0.783718E+10 | 646.47 | 0.187394E+11 | 0.822628E+10 | 0.00 | 1.00 | 01-AUG-20:08 | 0.00 | 01-AUG-00:35 | 28465.10 | 22-AUG-22:03 | 21154.51 | 13-AUG-18:08 | 11101.25 | 22-AUG-22:03 | 7279.81 | 06-AUG-18:08 | 0.00 | 01-AUG-00:05 |
September | 0.179457E+11 | 0.515916E+10 | 563.78 | 0.132528E+11 | 0.469287E+10 | 0.00 | 1.00 | 06-SEP-20:08 | 0.00 | 01-SEP-00:10 | 27700.34 | 06-SEP-20:08 | 20201.90 | 08-SEP-20:08 | 8268.16 | 06-SEP-20:08 | 6850.00 | 08-SEP-20:08 | 0.00 | 01-SEP-00:05 |
October | 0.102289E+11 | 0.289087E+10 | 408.07 | 0.833880E+10 | 0.189015E+10 | 0.00 | 0.94 | 10-OCT-20:43 | 0.00 | 01-OCT-00:10 | 24954.03 | 10-OCT-20:43 | 18582.57 | 10-OCT-20:43 | 7770.13 | 18-OCT-20:10 | 5923.48 | 10-OCT-20:43 | 0.00 | 01-OCT-00:10 |
November | 0.521375E+10 | 0.147995E+10 | 286.76 | 0.463393E+10 | 0.579814E+09 | 0.00 | 0.81 | 12-NOV-19:10 | 0.00 | 01-NOV-00:10 | 18187.97 | 12-NOV-19:10 | 18187.97 | 12-NOV-19:10 | 3017.94 | 05-NOV-12:40 | 4593.68 | 12-NOV-19:10 | 0.00 | 01-NOV-00:10 |
December | 0.201224E+10 | 0.578842E+09 | 161.42 | 0.178728E+10 | 0.224956E+09 | 0.00 | 0.52 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 11999.70 | 12-DEC-14:00 | 9708.30 | 12-DEC-14:00 | 2549.20 | 13-DEC-11:10 | 3289.76 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.136832E+12 | 0.397961E+11 | 4650.70 | 0.104291E+12 | 0.325409E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.596783E+09 | 0.175503E+09 | 70.00 | 0.527148E+09 | 69635061.00 | 0.00 | 0.29 | 0.00 | 6029.47 | 5384.28 | 1167.31 | 1725.84 | 0.00 | |||||||
Maximum of Months | 0.269657E+11 | 0.783718E+10 | 646.47 | 0.187394E+11 | 0.822628E+10 | 0.00 | 1.00 | 0.00 | 28465.10 | 21325.32 | 11101.25 | 7331.84 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.151840E+09 | 45343501.29 | 27.55 | 0.134061E+09 | 17778938.14 | 0.00 | 0.19 | 31-JAN-14:50 | 0.00 | 01-JAN-00:10 | 3476.79 | 31-JAN-14:40 | 2993.12 | 31-JAN-14:50 | 619.85 | 31-JAN-13:00 | 1019.97 | 31-JAN-14:40 | 0.00 | 01-JAN-00:10 |
February | 0.112087E+10 | 0.325612E+09 | 86.12 | 0.110833E+10 | 12549876.73 | 0.00 | 0.43 | 21-FEB-15:00 | 0.00 | 01-FEB-00:10 | 7854.21 | 28-FEB-15:30 | 7788.26 | 21-FEB-15:00 | 384.17 | 16-FEB-15:50 | 2277.04 | 28-FEB-15:30 | 0.00 | 01-FEB-00:10 |
March | 0.301152E+10 | 0.880058E+09 | 223.95 | 0.256202E+10 | 0.449502E+09 | 0.00 | 0.74 | 30-MAR-20:43 | 0.00 | 01-MAR-00:10 | 14796.63 | 30-MAR-20:43 | 12549.91 | 30-MAR-20:43 | 2618.72 | 30-MAR-11:35 | 4043.09 | 30-MAR-20:43 | 0.00 | 01-MAR-00:10 |
April | 0.506537E+10 | 0.150562E+10 | 293.97 | 0.421239E+10 | 0.852988E+09 | 0.00 | 0.62 | 16-APR-18:10 | 0.00 | 01-APR-00:10 | 11330.92 | 16-APR-18:10 | 10795.98 | 16-APR-18:10 | 2901.67 | 04-APR-14:10 | 3346.89 | 16-APR-18:10 | 0.00 | 01-APR-00:10 |
May | 0.970100E+10 | 0.285538E+10 | 415.28 | 0.733207E+10 | 0.236893E+10 | 0.00 | 0.81 | 29-MAY-18:10 | 0.00 | 01-MAY-00:10 | 17333.32 | 30-MAY-20:10 | 13781.96 | 29-MAY-18:10 | 6076.48 | 30-MAY-20:10 | 4841.13 | 29-MAY-18:10 | 0.00 | 01-MAY-00:10 |
June | 0.163139E+11 | 0.483092E+10 | 545.00 | 0.117687E+11 | 0.454513E+10 | 0.00 | 1.00 | 13-JUN-20:08 | 0.00 | 01-JUN-00:05 | 24041.91 | 28-JUN-20:43 | 17984.63 | 11-JUN-18:43 | 8209.88 | 28-JUN-20:43 | 6214.86 | 25-JUN-18:08 | 0.00 | 01-JUN-00:05 |
July | 0.199712E+11 | 0.587147E+10 | 603.15 | 0.135350E+11 | 0.643624E+10 | 0.00 | 1.00 | 02-JUL-18:08 | 0.00 | 01-JUL-00:05 | 24934.47 | 26-JUL-20:43 | 18113.98 | 16-JUL-18:08 | 10579.37 | 26-JUL-20:43 | 6396.14 | 09-JUL-18:08 | 0.00 | 01-JUL-00:05 |
August | 0.225639E+11 | 0.654760E+10 | 640.34 | 0.149501E+11 | 0.761378E+10 | 0.00 | 1.00 | 01-AUG-20:08 | 0.00 | 01-AUG-00:35 | 24965.34 | 11-AUG-20:43 | 17919.70 | 13-AUG-18:08 | 10715.46 | 11-AUG-20:43 | 6350.70 | 06-AUG-18:08 | 0.00 | 01-AUG-00:05 |
September | 0.139307E+11 | 0.401788E+10 | 522.23 | 0.980927E+10 | 0.412146E+10 | 0.00 | 1.00 | 06-SEP-20:08 | 0.00 | 01-SEP-00:05 | 24317.73 | 06-SEP-20:08 | 16823.15 | 08-SEP-20:08 | 8230.35 | 06-SEP-20:08 | 5981.69 | 08-SEP-20:08 | 0.00 | 01-SEP-00:05 |
October | 0.708302E+10 | 0.201044E+10 | 327.96 | 0.552896E+10 | 0.155406E+10 | 0.00 | 0.93 | 10-OCT-20:43 | 0.00 | 01-OCT-00:10 | 21498.82 | 10-OCT-20:43 | 15291.50 | 09-OCT-18:43 | 6357.99 | 10-OCT-20:43 | 5120.80 | 10-OCT-20:43 | 0.00 | 01-OCT-00:10 |
November | 0.287850E+10 | 0.823992E+09 | 205.92 | 0.248523E+10 | 0.393263E+09 | 0.00 | 0.46 | 05-NOV-18:20 | 0.00 | 01-NOV-00:10 | 9222.36 | 05-NOV-14:00 | 8312.53 | 08-NOV-15:10 | 2717.23 | 05-NOV-13:30 | 2577.40 | 05-NOV-14:00 | 0.00 | 01-NOV-00:10 |
December | 0.857754E+09 | 0.248397E+09 | 83.06 | 0.717527E+09 | 0.140226E+09 | 0.00 | 0.47 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 9236.03 | 12-DEC-14:00 | 7117.59 | 12-DEC-14:00 | 2205.49 | 12-DEC-12:30 | 2569.48 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.102650E+12 | 0.299627E+11 | 3974.54 | 0.741437E+11 | 0.285059E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.151840E+09 | 45343501.29 | 27.55 | 0.134061E+09 | 12549876.73 | 0.00 | 0.19 | 0.00 | 3476.79 | 2993.12 | 384.17 | 1019.97 | 0.00 | |||||||
Maximum of Months | 0.225639E+11 | 0.654760E+10 | 640.34 | 0.149501E+11 | 0.761378E+10 | 0.00 | 1.00 | 0.00 | 24965.34 | 18113.98 | 10715.46 | 6396.14 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.60 | 9.73 | 7.86 | 15.50 | 57.05 | 1.00 | 0.00 | 744.00 |
February | 21.99 | 13.62 | 8.37 | 25.85 | 49.44 | 2.67 | 0.00 | 672.00 |
March | 31.89 | 19.47 | 12.42 | 46.03 | 35.09 | 0.00 | 0.00 | 744.00 |
April | 40.09 | 24.70 | 15.39 | 66.46 | 28.49 | 0.00 | 0.00 | 720.00 |
May | 44.39 | 25.46 | 18.94 | 79.07 | 19.13 | 0.00 | 0.00 | 744.00 |
June | 47.36 | 27.70 | 19.66 | 90.86 | 13.56 | 0.00 | 0.00 | 720.00 |
July | 44.11 | 24.75 | 19.35 | 87.12 | 9.90 | 0.00 | 0.00 | 744.00 |
August | 40.60 | 22.02 | 18.58 | 80.96 | 9.26 | 0.00 | 0.00 | 744.00 |
September | 30.40 | 16.89 | 13.51 | 54.12 | 17.65 | 0.00 | 0.00 | 720.00 |
October | 26.08 | 17.53 | 8.55 | 39.96 | 32.71 | 0.00 | 0.00 | 744.00 |
November | 19.43 | 11.01 | 8.42 | 24.11 | 42.77 | 3.00 | 0.00 | 720.00 |
December | 15.91 | 8.68 | 7.23 | 15.09 | 50.40 | 6.33 | 0.00 | 744.00 |
Annual Sum or Average | 31.71 | 18.49 | 13.22 | 52.23 | 30.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 15.91 | 8.68 | 7.23 | 15.09 | 9.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 47.36 | 27.70 | 19.66 | 90.86 | 57.05 | 6.33 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1614.25 | 1125.85 | 488.41 | 1516.55 | 1096.29 | 0.00 | 0.00 | 744.00 |
February | 1503.05 | 1006.76 | 496.30 | 1437.77 | 963.33 | 0.00 | 0.00 | 672.00 |
March | 1347.91 | 699.59 | 648.32 | 1185.44 | 676.96 | 0.00 | 0.00 | 744.00 |
April | 1008.58 | 324.68 | 683.90 | 820.38 | 544.20 | 0.00 | 0.00 | 720.00 |
May | 816.57 | 92.55 | 724.03 | 795.87 | 353.21 | 0.00 | 0.00 | 744.00 |
June | 755.84 | 40.51 | 715.33 | 947.90 | 214.00 | 0.00 | 0.00 | 720.00 |
July | 763.92 | 55.23 | 708.69 | 990.66 | 141.32 | 0.00 | 0.00 | 744.00 |
August | 910.77 | 167.26 | 743.51 | 1095.04 | 117.68 | 0.00 | 0.00 | 744.00 |
September | 1000.79 | 369.28 | 631.51 | 1024.64 | 296.65 | 0.00 | 0.00 | 720.00 |
October | 1453.15 | 939.75 | 513.40 | 1517.18 | 645.68 | 0.00 | 0.00 | 744.00 |
November | 1568.04 | 1040.46 | 527.58 | 1628.42 | 828.41 | 0.00 | 0.00 | 720.00 |
December | 1592.11 | 1120.71 | 471.40 | 1586.18 | 970.95 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1193.27 | 579.91 | 613.36 | 1211.49 | 568.59 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 755.84 | 40.51 | 471.40 | 795.87 | 117.68 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1614.25 | 1125.85 | 743.51 | 1628.42 | 1096.29 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1614.25 | 1125.85 | 488.41 | 1528.41 | 1065.79 | 0.00 | 0.00 | 744.00 |
February | 1503.05 | 1006.76 | 496.30 | 1445.68 | 933.28 | 0.00 | 0.00 | 672.00 |
March | 1347.91 | 699.59 | 648.32 | 1194.21 | 650.31 | 0.00 | 0.00 | 744.00 |
April | 1008.58 | 324.68 | 683.90 | 826.61 | 523.49 | 0.00 | 0.00 | 720.00 |
May | 816.57 | 92.55 | 724.03 | 796.76 | 342.58 | 0.00 | 0.00 | 744.00 |
June | 755.84 | 40.51 | 715.33 | 944.79 | 209.74 | 0.00 | 0.00 | 720.00 |
July | 763.92 | 55.23 | 708.69 | 987.63 | 138.04 | 0.00 | 0.00 | 744.00 |
August | 910.77 | 167.26 | 743.51 | 1091.96 | 113.94 | 0.00 | 0.00 | 744.00 |
September | 1000.79 | 369.28 | 631.51 | 1022.84 | 291.30 | 0.00 | 0.00 | 720.00 |
October | 1453.15 | 939.75 | 513.40 | 1520.58 | 626.71 | 0.00 | 0.00 | 744.00 |
November | 1568.04 | 1040.46 | 527.58 | 1636.36 | 800.86 | 0.00 | 0.00 | 720.00 |
December | 1592.11 | 1120.71 | 471.40 | 1597.76 | 933.24 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1193.27 | 579.91 | 613.36 | 1215.43 | 550.36 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 755.84 | 40.51 | 471.40 | 796.76 | 113.94 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1614.25 | 1125.85 | 743.51 | 1636.36 | 1065.79 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 332.16 | 231.66 | 100.50 | 307.87 | 218.10 | 0.00 | 0.00 | 744.00 |
February | 309.28 | 207.16 | 102.12 | 292.64 | 190.49 | 0.00 | 0.00 | 672.00 |
March | 277.35 | 143.95 | 133.40 | 245.89 | 129.33 | 0.00 | 0.00 | 744.00 |
April | 207.53 | 66.81 | 140.72 | 168.73 | 105.16 | 0.00 | 0.00 | 720.00 |
May | 168.02 | 19.04 | 148.98 | 157.47 | 70.56 | 0.00 | 0.00 | 744.00 |
June | 155.53 | 8.34 | 147.19 | 169.74 | 51.17 | 0.00 | 0.00 | 720.00 |
July | 157.19 | 11.36 | 145.82 | 173.53 | 38.45 | 0.00 | 0.00 | 744.00 |
August | 187.40 | 34.42 | 152.99 | 194.40 | 36.63 | 0.00 | 0.00 | 744.00 |
September | 205.93 | 75.98 | 129.94 | 198.66 | 66.45 | 0.00 | 0.00 | 720.00 |
October | 299.01 | 193.37 | 105.64 | 309.59 | 127.29 | 0.00 | 0.00 | 744.00 |
November | 322.65 | 214.09 | 108.56 | 334.98 | 158.63 | 0.00 | 0.00 | 720.00 |
December | 327.60 | 230.60 | 97.00 | 323.91 | 187.95 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 245.53 | 119.32 | 126.21 | 239.59 | 114.61 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 155.53 | 8.34 | 97.00 | 157.47 | 36.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 332.16 | 231.66 | 152.99 | 334.98 | 218.10 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47137309.01 | 26073446.72 | 21063862.29 | 41505767.52 | 0.152811E+09 |
February | 53188989.15 | 32951343.71 | 20237645.44 | 62533393.93 | 0.119593E+09 |
March | 85406712.70 | 52151337.10 | 33255375.60 | 0.123282E+09 | 93987723.58 |
April | 0.103919E+09 | 64029798.25 | 39889592.35 | 0.172253E+09 | 73836470.82 |
May | 0.118901E+09 | 68184298.97 | 50716974.87 | 0.211787E+09 | 51226441.99 |
June | 0.122759E+09 | 71802655.99 | 50956474.47 | 0.235504E+09 | 35146953.54 |
July | 0.118132E+09 | 66297322.18 | 51834665.63 | 0.233329E+09 | 26504391.77 |
August | 0.108746E+09 | 58988108.35 | 49757827.95 | 0.216842E+09 | 24815161.91 |
September | 78801550.20 | 43774141.09 | 35027409.12 | 0.140273E+09 | 45757759.49 |
October | 69862264.50 | 46949808.72 | 22912455.79 | 0.107016E+09 | 87618796.54 |
November | 50375466.04 | 28538389.80 | 21837076.24 | 62487757.27 | 0.110849E+09 |
December | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 0.134981E+09 |
Annual Sum or Average | 0.999850E+09 | 0.582991E+09 | 0.416860E+09 | 0.164724E+10 | 0.957128E+09 |
Minimum of Months | 42620158.43 | 23249877.35 | 19370281.08 | 40429854.11 | 24815161.91 |
Maximum of Months | 0.122759E+09 | 71802655.99 | 51834665.63 | 0.235504E+09 | 0.152811E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.432361E+10 | 0.301547E+10 | 0.130815E+10 | 0.406194E+10 | 0.293629E+10 |
February | 0.363619E+10 | 0.243555E+10 | 0.120064E+10 | 0.347825E+10 | 0.233048E+10 |
March | 0.361023E+10 | 0.187378E+10 | 0.173646E+10 | 0.317507E+10 | 0.181316E+10 |
April | 0.261424E+10 | 0.841577E+09 | 0.177267E+10 | 0.212643E+10 | 0.141056E+10 |
May | 0.218711E+10 | 0.247879E+09 | 0.193923E+10 | 0.213166E+10 | 0.946040E+09 |
June | 0.195914E+10 | 0.105014E+09 | 0.185413E+10 | 0.245697E+10 | 0.554695E+09 |
July | 0.204608E+10 | 0.147916E+09 | 0.189816E+10 | 0.265338E+10 | 0.378504E+09 |
August | 0.243939E+10 | 0.447976E+09 | 0.199142E+10 | 0.293294E+10 | 0.315201E+09 |
September | 0.259405E+10 | 0.957170E+09 | 0.163688E+10 | 0.265588E+10 | 0.768912E+09 |
October | 0.389211E+10 | 0.251702E+10 | 0.137510E+10 | 0.406361E+10 | 0.172938E+10 |
November | 0.406435E+10 | 0.269687E+10 | 0.136748E+10 | 0.422087E+10 | 0.214724E+10 |
December | 0.426430E+10 | 0.300170E+10 | 0.126260E+10 | 0.424844E+10 | 0.260059E+10 |
Annual Sum or Average | 0.376308E+11 | 0.182879E+11 | 0.193429E+11 | 0.382054E+11 | 0.179311E+11 |
Minimum of Months | 0.195914E+10 | 0.105014E+09 | 0.120064E+10 | 0.212643E+10 | 0.315201E+09 |
Maximum of Months | 0.432361E+10 | 0.301547E+10 | 0.199142E+10 | 0.424844E+10 | 0.293629E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.432361E+10 | 0.301547E+10 | 0.130815E+10 | 0.409369E+10 | 0.285462E+10 |
February | 0.363619E+10 | 0.243555E+10 | 0.120064E+10 | 0.349739E+10 | 0.225779E+10 |
March | 0.361023E+10 | 0.187378E+10 | 0.173646E+10 | 0.319857E+10 | 0.174179E+10 |
April | 0.261424E+10 | 0.841577E+09 | 0.177267E+10 | 0.214257E+10 | 0.135688E+10 |
May | 0.218711E+10 | 0.247879E+09 | 0.193923E+10 | 0.213405E+10 | 0.917571E+09 |
June | 0.195914E+10 | 0.105014E+09 | 0.185413E+10 | 0.244890E+10 | 0.543642E+09 |
July | 0.204608E+10 | 0.147916E+09 | 0.189816E+10 | 0.264527E+10 | 0.369722E+09 |
August | 0.243939E+10 | 0.447976E+09 | 0.199142E+10 | 0.292469E+10 | 0.305173E+09 |
September | 0.259405E+10 | 0.957170E+09 | 0.163688E+10 | 0.265121E+10 | 0.755041E+09 |
October | 0.389211E+10 | 0.251702E+10 | 0.137510E+10 | 0.407272E+10 | 0.167857E+10 |
November | 0.406435E+10 | 0.269687E+10 | 0.136748E+10 | 0.424145E+10 | 0.207582E+10 |
December | 0.426430E+10 | 0.300170E+10 | 0.126260E+10 | 0.427945E+10 | 0.249960E+10 |
Annual Sum or Average | 0.376308E+11 | 0.182879E+11 | 0.193429E+11 | 0.383300E+11 | 0.173562E+11 |
Minimum of Months | 0.195914E+10 | 0.105014E+09 | 0.120064E+10 | 0.213405E+10 | 0.305173E+09 |
Maximum of Months | 0.432361E+10 | 0.301547E+10 | 0.199142E+10 | 0.427945E+10 | 0.285462E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.889647E+09 | 0.620476E+09 | 0.269171E+09 | 0.824602E+09 | 0.584170E+09 |
February | 0.748199E+09 | 0.501150E+09 | 0.247049E+09 | 0.707945E+09 | 0.460845E+09 |
March | 0.742858E+09 | 0.385557E+09 | 0.357302E+09 | 0.658600E+09 | 0.346386E+09 |
April | 0.537919E+09 | 0.173167E+09 | 0.364752E+09 | 0.437344E+09 | 0.272587E+09 |
May | 0.450030E+09 | 51004710.77 | 0.399025E+09 | 0.421776E+09 | 0.188998E+09 |
June | 0.403122E+09 | 21608090.87 | 0.381514E+09 | 0.439958E+09 | 0.132634E+09 |
July | 0.421011E+09 | 30435973.32 | 0.390575E+09 | 0.464791E+09 | 0.102978E+09 |
August | 0.501941E+09 | 92177600.96 | 0.409763E+09 | 0.520687E+09 | 98107927.51 |
September | 0.533764E+09 | 0.196952E+09 | 0.336812E+09 | 0.514939E+09 | 0.172248E+09 |
October | 0.800859E+09 | 0.517913E+09 | 0.282946E+09 | 0.829202E+09 | 0.340931E+09 |
November | 0.836299E+09 | 0.554920E+09 | 0.281379E+09 | 0.868275E+09 | 0.411167E+09 |
December | 0.877442E+09 | 0.617644E+09 | 0.259798E+09 | 0.867564E+09 | 0.503395E+09 |
Annual Sum or Average | 0.774309E+10 | 0.376300E+10 | 0.398009E+10 | 0.755568E+10 | 0.361445E+10 |
Minimum of Months | 0.403122E+09 | 21608090.87 | 0.247049E+09 | 0.421776E+09 | 98107927.51 |
Maximum of Months | 0.889647E+09 | 0.620476E+09 | 0.409763E+09 | 0.868275E+09 | 0.584170E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 123.97 | 456.42 | 140.79 | 77.88 | 62.91 | 0.00 | 0.00 |
February | 206.79 | 395.48 | 175.89 | 108.97 | 66.92 | 0.00 | 0.00 |
March | 368.23 | 280.73 | 255.10 | 155.77 | 99.33 | 0.00 | 0.00 |
April | 531.65 | 227.89 | 320.74 | 197.62 | 123.12 | 0.00 | 0.00 |
May | 632.58 | 153.01 | 355.14 | 203.66 | 151.48 | 0.00 | 0.00 |
June | 726.87 | 108.48 | 378.89 | 221.61 | 157.27 | 0.00 | 0.00 |
July | 696.92 | 79.16 | 352.84 | 198.02 | 154.82 | 0.00 | 0.00 |
August | 647.68 | 74.12 | 324.81 | 176.19 | 148.62 | 0.00 | 0.00 |
September | 432.94 | 141.23 | 243.21 | 135.11 | 108.11 | 0.00 | 0.00 |
October | 319.64 | 261.70 | 208.67 | 140.23 | 68.44 | 0.00 | 0.00 |
November | 192.86 | 342.13 | 155.48 | 88.08 | 67.40 | 0.00 | 0.00 |
December | 120.76 | 403.17 | 127.30 | 69.44 | 57.86 | 0.00 | 0.00 |
Annual Sum or Average | 417.87 | 242.80 | 253.64 | 147.89 | 105.75 | 0.00 | 0.00 |
Minimum of Months | 120.76 | 74.12 | 127.30 | 69.44 | 57.86 | 0.00 | 0.00 |
Maximum of Months | 726.87 | 456.42 | 378.89 | 221.61 | 157.27 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1516.55 | 1096.29 | 1614.25 | 1125.85 | 488.41 | 0.00 | 0.00 |
February | 1437.77 | 963.33 | 1503.05 | 1006.76 | 496.30 | 0.00 | 0.00 |
March | 1185.44 | 676.96 | 1347.91 | 699.59 | 648.32 | 0.00 | 0.00 |
April | 820.38 | 544.20 | 1008.58 | 324.68 | 683.90 | 0.00 | 0.00 |
May | 795.87 | 353.21 | 816.57 | 92.55 | 724.03 | 0.00 | 0.00 |
June | 947.90 | 214.00 | 755.84 | 40.51 | 715.33 | 0.00 | 0.00 |
July | 990.66 | 141.32 | 763.92 | 55.23 | 708.69 | 0.00 | 0.00 |
August | 1095.04 | 117.68 | 910.77 | 167.26 | 743.51 | 0.00 | 0.00 |
September | 1024.64 | 296.65 | 1000.79 | 369.28 | 631.51 | 0.00 | 0.00 |
October | 1517.18 | 645.68 | 1453.15 | 939.75 | 513.40 | 0.00 | 0.00 |
November | 1628.42 | 828.41 | 1568.04 | 1040.46 | 527.58 | 0.00 | 0.00 |
December | 1586.18 | 970.95 | 1592.11 | 1120.71 | 471.40 | 0.00 | 0.00 |
Annual Sum or Average | 1211.49 | 568.59 | 1193.27 | 579.91 | 613.36 | 0.00 | 0.00 |
Minimum of Months | 795.87 | 117.68 | 755.84 | 40.51 | 471.40 | 0.00 | 0.00 |
Maximum of Months | 1628.42 | 1096.29 | 1614.25 | 1125.85 | 743.51 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1528.41 | 1065.79 | 1614.25 | 1125.85 | 488.41 | 0.00 | 0.00 |
February | 1445.68 | 933.28 | 1503.05 | 1006.76 | 496.30 | 0.00 | 0.00 |
March | 1194.21 | 650.31 | 1347.91 | 699.59 | 648.32 | 0.00 | 0.00 |
April | 826.61 | 523.49 | 1008.58 | 324.68 | 683.90 | 0.00 | 0.00 |
May | 796.76 | 342.58 | 816.57 | 92.55 | 724.03 | 0.00 | 0.00 |
June | 944.79 | 209.74 | 755.84 | 40.51 | 715.33 | 0.00 | 0.00 |
July | 987.63 | 138.04 | 763.92 | 55.23 | 708.69 | 0.00 | 0.00 |
August | 1091.96 | 113.94 | 910.77 | 167.26 | 743.51 | 0.00 | 0.00 |
September | 1022.84 | 291.30 | 1000.79 | 369.28 | 631.51 | 0.00 | 0.00 |
October | 1520.58 | 626.71 | 1453.15 | 939.75 | 513.40 | 0.00 | 0.00 |
November | 1636.36 | 800.86 | 1568.04 | 1040.46 | 527.58 | 0.00 | 0.00 |
December | 1597.76 | 933.24 | 1592.11 | 1120.71 | 471.40 | 0.00 | 0.00 |
Annual Sum or Average | 1215.43 | 550.36 | 1193.27 | 579.91 | 613.36 | 0.00 | 0.00 |
Minimum of Months | 796.76 | 113.94 | 755.84 | 40.51 | 471.40 | 0.00 | 0.00 |
Maximum of Months | 1636.36 | 1065.79 | 1614.25 | 1125.85 | 743.51 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 307.87 | 218.10 | 332.16 | 231.66 | 100.50 | 0.00 | 0.00 |
February | 292.64 | 190.49 | 309.28 | 207.16 | 102.12 | 0.00 | 0.00 |
March | 245.89 | 129.33 | 277.35 | 143.95 | 133.40 | 0.00 | 0.00 |
April | 168.73 | 105.16 | 207.53 | 66.81 | 140.72 | 0.00 | 0.00 |
May | 157.47 | 70.56 | 168.02 | 19.04 | 148.98 | 0.00 | 0.00 |
June | 169.74 | 51.17 | 155.53 | 8.34 | 147.19 | 0.00 | 0.00 |
July | 173.53 | 38.45 | 157.19 | 11.36 | 145.82 | 0.00 | 0.00 |
August | 194.40 | 36.63 | 187.40 | 34.42 | 152.99 | 0.00 | 0.00 |
September | 198.66 | 66.45 | 205.93 | 75.98 | 129.94 | 0.00 | 0.00 |
October | 309.59 | 127.29 | 299.01 | 193.37 | 105.64 | 0.00 | 0.00 |
November | 334.98 | 158.63 | 322.65 | 214.09 | 108.56 | 0.00 | 0.00 |
December | 323.91 | 187.95 | 327.60 | 230.60 | 97.00 | 0.00 | 0.00 |
Annual Sum or Average | 239.59 | 114.61 | 245.53 | 119.32 | 126.21 | 0.00 | 0.00 |
Minimum of Months | 157.47 | 36.63 | 155.53 | 8.34 | 97.00 | 0.00 | 0.00 |
Maximum of Months | 334.98 | 218.10 | 332.16 | 231.66 | 152.99 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.332046E+09 | 0.122248E+10 | 0.377098E+09 | 0.208588E+09 | 0.168511E+09 | 0.00 | 0.00 |
February | 0.500267E+09 | 0.956748E+09 | 0.425512E+09 | 0.263611E+09 | 0.161901E+09 | 0.00 | 0.00 |
March | 0.986257E+09 | 0.751902E+09 | 0.683254E+09 | 0.417211E+09 | 0.266043E+09 | 0.00 | 0.00 |
April | 0.137803E+10 | 0.590692E+09 | 0.831355E+09 | 0.512238E+09 | 0.319117E+09 | 0.00 | 0.00 |
May | 0.169430E+10 | 0.409812E+09 | 0.951210E+09 | 0.545474E+09 | 0.405736E+09 | 0.00 | 0.00 |
June | 0.188403E+10 | 0.281176E+09 | 0.982073E+09 | 0.574421E+09 | 0.407652E+09 | 0.00 | 0.00 |
July | 0.186663E+10 | 0.212035E+09 | 0.945056E+09 | 0.530379E+09 | 0.414677E+09 | 0.00 | 0.00 |
August | 0.173474E+10 | 0.198521E+09 | 0.869967E+09 | 0.471905E+09 | 0.398063E+09 | 0.00 | 0.00 |
September | 0.112219E+10 | 0.366062E+09 | 0.630412E+09 | 0.350193E+09 | 0.280219E+09 | 0.00 | 0.00 |
October | 0.856131E+09 | 0.700950E+09 | 0.558898E+09 | 0.375598E+09 | 0.183300E+09 | 0.00 | 0.00 |
November | 0.499902E+09 | 0.886792E+09 | 0.403004E+09 | 0.228307E+09 | 0.174697E+09 | 0.00 | 0.00 |
December | 0.323439E+09 | 0.107985E+10 | 0.340961E+09 | 0.185999E+09 | 0.154962E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.131780E+11 | 0.765702E+10 | 0.799880E+10 | 0.466392E+10 | 0.333488E+10 | 0.00 | 0.00 |
Minimum of Months | 0.323439E+09 | 0.198521E+09 | 0.340961E+09 | 0.185999E+09 | 0.154962E+09 | 0.00 | 0.00 |
Maximum of Months | 0.188403E+10 | 0.122248E+10 | 0.982073E+09 | 0.574421E+09 | 0.414677E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.406194E+10 | 0.293629E+10 | 0.432361E+10 | 0.301547E+10 | 0.130815E+10 | 0.00 | 0.00 |
February | 0.347825E+10 | 0.233048E+10 | 0.363619E+10 | 0.243555E+10 | 0.120064E+10 | 0.00 | 0.00 |
March | 0.317507E+10 | 0.181316E+10 | 0.361023E+10 | 0.187378E+10 | 0.173646E+10 | 0.00 | 0.00 |
April | 0.212643E+10 | 0.141056E+10 | 0.261424E+10 | 0.841577E+09 | 0.177267E+10 | 0.00 | 0.00 |
May | 0.213166E+10 | 0.946040E+09 | 0.218711E+10 | 0.247879E+09 | 0.193923E+10 | 0.00 | 0.00 |
June | 0.245697E+10 | 0.554695E+09 | 0.195914E+10 | 0.105014E+09 | 0.185413E+10 | 0.00 | 0.00 |
July | 0.265338E+10 | 0.378504E+09 | 0.204608E+10 | 0.147916E+09 | 0.189816E+10 | 0.00 | 0.00 |
August | 0.293294E+10 | 0.315201E+09 | 0.243939E+10 | 0.447976E+09 | 0.199142E+10 | 0.00 | 0.00 |
September | 0.265588E+10 | 0.768912E+09 | 0.259405E+10 | 0.957170E+09 | 0.163688E+10 | 0.00 | 0.00 |
October | 0.406361E+10 | 0.172938E+10 | 0.389211E+10 | 0.251702E+10 | 0.137510E+10 | 0.00 | 0.00 |
November | 0.422087E+10 | 0.214724E+10 | 0.406435E+10 | 0.269687E+10 | 0.136748E+10 | 0.00 | 0.00 |
December | 0.424844E+10 | 0.260059E+10 | 0.426430E+10 | 0.300170E+10 | 0.126260E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.382054E+11 | 0.179311E+11 | 0.376308E+11 | 0.182879E+11 | 0.193429E+11 | 0.00 | 0.00 |
Minimum of Months | 0.212643E+10 | 0.315201E+09 | 0.195914E+10 | 0.105014E+09 | 0.120064E+10 | 0.00 | 0.00 |
Maximum of Months | 0.424844E+10 | 0.293629E+10 | 0.432361E+10 | 0.301547E+10 | 0.199142E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.409369E+10 | 0.285462E+10 | 0.432361E+10 | 0.301547E+10 | 0.130815E+10 | 0.00 | 0.00 |
February | 0.349739E+10 | 0.225779E+10 | 0.363619E+10 | 0.243555E+10 | 0.120064E+10 | 0.00 | 0.00 |
March | 0.319857E+10 | 0.174179E+10 | 0.361023E+10 | 0.187378E+10 | 0.173646E+10 | 0.00 | 0.00 |
April | 0.214257E+10 | 0.135688E+10 | 0.261424E+10 | 0.841577E+09 | 0.177267E+10 | 0.00 | 0.00 |
May | 0.213405E+10 | 0.917571E+09 | 0.218711E+10 | 0.247879E+09 | 0.193923E+10 | 0.00 | 0.00 |
June | 0.244890E+10 | 0.543642E+09 | 0.195914E+10 | 0.105014E+09 | 0.185413E+10 | 0.00 | 0.00 |
July | 0.264527E+10 | 0.369722E+09 | 0.204608E+10 | 0.147916E+09 | 0.189816E+10 | 0.00 | 0.00 |
August | 0.292469E+10 | 0.305173E+09 | 0.243939E+10 | 0.447976E+09 | 0.199142E+10 | 0.00 | 0.00 |
September | 0.265121E+10 | 0.755041E+09 | 0.259405E+10 | 0.957170E+09 | 0.163688E+10 | 0.00 | 0.00 |
October | 0.407272E+10 | 0.167857E+10 | 0.389211E+10 | 0.251702E+10 | 0.137510E+10 | 0.00 | 0.00 |
November | 0.424145E+10 | 0.207582E+10 | 0.406435E+10 | 0.269687E+10 | 0.136748E+10 | 0.00 | 0.00 |
December | 0.427945E+10 | 0.249960E+10 | 0.426430E+10 | 0.300170E+10 | 0.126260E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.383300E+11 | 0.173562E+11 | 0.376308E+11 | 0.182879E+11 | 0.193429E+11 | 0.00 | 0.00 |
Minimum of Months | 0.213405E+10 | 0.305173E+09 | 0.195914E+10 | 0.105014E+09 | 0.120064E+10 | 0.00 | 0.00 |
Maximum of Months | 0.427945E+10 | 0.285462E+10 | 0.432361E+10 | 0.301547E+10 | 0.199142E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.824602E+09 | 0.584170E+09 | 0.889647E+09 | 0.620476E+09 | 0.269171E+09 | 0.00 | 0.00 |
February | 0.707945E+09 | 0.460845E+09 | 0.748199E+09 | 0.501150E+09 | 0.247049E+09 | 0.00 | 0.00 |
March | 0.658600E+09 | 0.346386E+09 | 0.742858E+09 | 0.385557E+09 | 0.357302E+09 | 0.00 | 0.00 |
April | 0.437344E+09 | 0.272587E+09 | 0.537919E+09 | 0.173167E+09 | 0.364752E+09 | 0.00 | 0.00 |
May | 0.421776E+09 | 0.188998E+09 | 0.450030E+09 | 51004710.77 | 0.399025E+09 | 0.00 | 0.00 |
June | 0.439958E+09 | 0.132634E+09 | 0.403122E+09 | 21608090.87 | 0.381514E+09 | 0.00 | 0.00 |
July | 0.464791E+09 | 0.102978E+09 | 0.421011E+09 | 30435973.32 | 0.390575E+09 | 0.00 | 0.00 |
August | 0.520687E+09 | 98107927.51 | 0.501941E+09 | 92177600.96 | 0.409763E+09 | 0.00 | 0.00 |
September | 0.514939E+09 | 0.172248E+09 | 0.533764E+09 | 0.196952E+09 | 0.336812E+09 | 0.00 | 0.00 |
October | 0.829202E+09 | 0.340931E+09 | 0.800859E+09 | 0.517913E+09 | 0.282946E+09 | 0.00 | 0.00 |
November | 0.868275E+09 | 0.411167E+09 | 0.836299E+09 | 0.554920E+09 | 0.281379E+09 | 0.00 | 0.00 |
December | 0.867564E+09 | 0.503395E+09 | 0.877442E+09 | 0.617644E+09 | 0.259798E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.755568E+10 | 0.361445E+10 | 0.774309E+10 | 0.376300E+10 | 0.398009E+10 | 0.00 | 0.00 |
Minimum of Months | 0.421776E+09 | 98107927.51 | 0.403122E+09 | 21608090.87 | 0.247049E+09 | 0.00 | 0.00 |
Maximum of Months | 0.868275E+09 | 0.584170E+09 | 0.889647E+09 | 0.620476E+09 | 0.409763E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 3.96 | 1.45 | -3.0 | 4.56 | -7.9 | 48.74 | 150.20 | 0.00 |
February | 7.94 | 4.23 | -1.3 | 5.19 | -4.0 | 51.84 | 169.20 | 0.00 |
March | 13.76 | 8.96 | 3.80 | 4.89 | 2.24 | 76.95 | 193.22 | 0.00 |
April | 17.21 | 12.53 | 8.82 | 3.95 | 6.45 | 95.37 | 211.82 | 0.00 |
May | 20.84 | 16.43 | 13.69 | 3.50 | 11.45 | 117.34 | 200.00 | 0.00 |
June | 24.80 | 19.34 | 16.45 | 3.85 | 15.08 | 121.81 | 213.08 | 0.00 |
July | 26.06 | 21.67 | 19.85 | 3.24 | 17.63 | 119.92 | 194.46 | 0.00 |
August | 26.55 | 22.41 | 20.72 | 3.39 | 18.20 | 115.12 | 179.15 | 0.00 |
September | 22.53 | 18.74 | 16.82 | 3.06 | 13.43 | 83.74 | 156.58 | 0.02 |
October | 16.03 | 13.01 | 10.77 | 4.05 | 5.85 | 53.01 | 190.38 | 0.00 |
November | 11.94 | 8.21 | 4.17 | 4.16 | 0.29 | 52.20 | 150.38 | 0.00 |
December | 7.70 | 4.67 | 0.26 | 4.69 | -4.1 | 44.81 | 142.03 | 0.00 |
Annual Sum or Average | 16.65 | 12.68 | 9.31 | 4.04 | 6.28 | 81.91 | 179.25 | 0.00 |
Minimum of Months | 3.96 | 1.45 | -3.0 | 3.06 | -7.9 | 44.81 | 142.03 | 0.00 |
Maximum of Months | 26.55 | 22.41 | 20.72 | 5.19 | 18.20 | 121.81 | 213.08 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.10 | 31-JAN-14:00 | 12.95 | 6.70 | 5.70 | 12.22 | 200.50 | 90.50 |
February | 25.00 | 26-FEB-14:00 | 12.72 | 1.70 | 4.10 | 8.15 | 91.50 | 816.00 |
March | 27.80 | 30-MAR-13:00 | 17.85 | 12.20 | 5.70 | 16.30 | 231.50 | 710.50 |
April | 28.90 | 17-APR-14:20 | 16.53 | 8.13 | 2.03 | 13.35 | 125.83 | 887.67 |
May | 30.60 | 19-MAY-13:00 | 18.47 | 11.70 | 4.60 | 15.76 | 140.00 | 875.50 |
June | 34.40 | 06-JUN-14:00 | 22.37 | 17.20 | 8.20 | 22.13 | 251.00 | 561.00 |
July | 36.70 | 08-JUL-14:00 | 23.89 | 18.90 | 2.10 | 24.66 | 274.00 | 567.00 |
August | 35.00 | 01-AUG-14:00 | 23.82 | 19.40 | 2.60 | 26.15 | 306.00 | 508.00 |
September | 31.70 | 07-SEP-15:09 | 23.04 | 19.60 | 4.02 | 22.55 | 218.67 | 591.33 |
October | 30.00 | 10-OCT-15:00 | 20.54 | 16.10 | 3.60 | 17.57 | 97.00 | 561.00 |
November | 24.40 | 05-NOV-15:00 | 17.94 | 14.40 | 2.10 | 14.10 | 117.50 | 361.50 |
December | 22.80 | 12-DEC-14:20 | 16.76 | 13.33 | 5.20 | 13.35 | 144.17 | 433.83 |
Annual Sum or Average | ||||||||
Minimum of Months | 21.10 | 12.72 | 1.70 | 2.03 | 8.15 | 91.50 | 90.50 | |
Maximum of Months | 36.70 | 23.89 | 19.60 | 8.20 | 26.15 | 306.00 | 887.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.7 | 14-JAN-06:10 | -7.7 | -10.6 | 4.95 | -24.7 | 0.00 | 0.00 |
February | -12.8 | 12-FEB-06:00 | -13.7 | -18.3 | 7.20 | -30.1 | 0.00 | 0.00 |
March | 1.10 | 19-MAR-06:00 | -1.4 | -6.1 | 0.00 | -16.2 | 17.00 | 290.50 |
April | 0.00 | 06-APR-04:00 | -1.0 | -2.8 | 3.10 | -16.5 | 0.00 | 0.00 |
May | 7.80 | 11-MAY-05:00 | 5.44 | 2.80 | 4.10 | -7.8 | 21.50 | 204.50 |
June | 11.10 | 10-JUN-04:00 | 8.73 | 6.70 | 0.00 | -2.5 | 0.00 | 0.00 |
July | 17.20 | 28-JUL-22:00 | 16.88 | 16.70 | 4.10 | 14.28 | 0.00 | 0.00 |
August | 18.30 | 25-AUG-05:00 | 17.20 | 16.70 | 3.60 | 5.13 | 0.00 | 0.00 |
September | 11.70 | 29-SEP-03:00 | 11.07 | 10.60 | 2.60 | -2.3 | 0.00 | 0.00 |
October | 2.20 | 26-OCT-04:00 | 1.95 | 1.70 | 3.10 | -13.4 | 0.00 | 0.00 |
November | -3.3 | 22-NOV-05:00 | -4.0 | -5.6 | 5.20 | -20.2 | 0.00 | 0.00 |
December | -5.6 | 18-DEC-07:00 | -7.1 | -11.7 | 2.60 | -22.7 | 17.00 | 320.50 |
Annual Sum or Average | ||||||||
Minimum of Months | -12.8 | -13.7 | -18.3 | 0.00 | -30.1 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 17.20 | 16.70 | 7.20 | 14.28 | 21.50 | 320.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 16.51 | 19-JAN-21:00 | 18.30 | 15.60 | 8.80 | 15.21 | 0.00 | 0.00 |
February | 15.80 | 18-FEB-15:00 | 17.20 | 15.00 | 5.20 | 13.91 | 73.00 | 1.00 |
March | 18.15 | 30-MAR-12:30 | 25.85 | 13.85 | 5.45 | 15.39 | 323.00 | 600.00 |
April | 20.00 | 04-APR-13:00 | 25.00 | 17.80 | 9.30 | 18.64 | 307.00 | 197.50 |
May | 22.33 | 30-MAY-17:00 | 27.80 | 20.00 | 4.10 | 21.96 | 97.50 | 79.50 |
June | 24.31 | 23-JUN-11:39 | 31.13 | 21.87 | 4.83 | 22.98 | 338.17 | 565.17 |
July | 25.05 | 07-JUL-11:00 | 33.30 | 22.20 | 3.60 | 20.75 | 116.50 | 900.00 |
August | 25.12 | 19-AUG-16:00 | 30.00 | 23.30 | 3.10 | 23.66 | 197.00 | 136.50 |
September | 24.09 | 09-SEP-10:00 | 30.60 | 21.70 | 2.60 | 21.27 | 236.00 | 482.00 |
October | 23.19 | 18-OCT-15:00 | 25.60 | 22.20 | 5.70 | 23.82 | 159.00 | 2.00 |
November | 18.87 | 19-NOV-14:00 | 24.40 | 16.10 | 8.20 | 13.91 | 143.00 | 384.50 |
December | 17.57 | 13-DEC-10:00 | 19.40 | 16.70 | 4.60 | 14.47 | 227.50 | 77.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.80 | 17.20 | 13.85 | 2.60 | 13.91 | 0.00 | 0.00 | |
Maximum of Months | 25.12 | 33.30 | 23.30 | 9.30 | 23.82 | 338.17 | 900.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 15.60 | 19-JAN-17:00 | 17.20 | 16.13 | 6.70 | 14.10 | 0.00 | 0.00 |
February | 15.00 | 18-FEB-16:19 | 17.20 | 15.80 | 5.53 | 13.91 | 50.33 | 1.00 |
March | 16.10 | 31-MAR-10:00 | 21.70 | 18.06 | 13.90 | 18.64 | 268.00 | 8.00 |
April | 17.80 | 04-APR-09:20 | 20.77 | 18.74 | 7.53 | 16.78 | 242.00 | 111.50 |
May | 20.60 | 30-MAY-19:00 | 25.00 | 21.79 | 2.60 | 12.41 | 0.00 | 0.00 |
June | 22.80 | 18-JUN-16:00 | 28.30 | 24.23 | 0.00 | 24.66 | 140.50 | 115.50 |
July | 23.30 | 26-JUL-09:00 | 26.10 | 24.09 | 3.60 | 24.66 | 338.00 | 251.50 |
August | 23.90 | 08-AUG-19:00 | 26.10 | 24.51 | 1.50 | 24.83 | 0.00 | 0.00 |
September | 23.30 | 16-SEP-16:00 | 25.60 | 23.88 | 2.10 | 22.13 | 108.00 | 57.50 |
October | 22.20 | 18-OCT-14:00 | 25.00 | 23.04 | 4.60 | 23.32 | 234.50 | 2.00 |
November | 17.20 | 04-NOV-13:00 | 17.80 | 17.48 | 3.60 | 15.02 | 276.50 | 2.50 |
December | 16.70 | 13-DEC-16:19 | 17.03 | 16.82 | 2.93 | 14.10 | 54.00 | 4.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.00 | 17.03 | 15.80 | 0.00 | 12.41 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 28.30 | 24.51 | 13.90 | 24.83 | 338.00 | 251.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 13.74 | 22.89 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 13.65 | 27.55 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 15.17 | 38.46 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 17.98 | 47.59 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 21.32 | 52.44 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 24.28 | 55.84 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 26.07 | 52.33 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 26.20 | 48.31 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 24.63 | 36.35 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 21.78 | 31.91 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.45 | 24.33 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 15.51 | 20.76 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.94 | 38.29 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 13.65 | 20.76 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 26.20 | 55.84 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.271724E+10 | -.214397E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -573273481.5 | 58.99 | 0.00 | 0.00 |
February | 0.246162E+10 | -.195630E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -505322256.9 | 58.99 | 0.00 | 0.00 |
March | 0.268193E+10 | -.214515E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -536782170.6 | 58.99 | 0.00 | 0.00 |
April | 0.241646E+10 | -.190922E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -507239899.2 | 58.99 | 0.00 | 0.00 |
May | 0.233211E+10 | -.181624E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -515876628.4 | 58.99 | 0.00 | 0.00 |
June | 0.213850E+10 | -.164084E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -497660277.5 | 58.99 | 0.00 | 0.00 |
July | 0.207519E+10 | -.156101E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -514184668.4 | 58.99 | 0.00 | 0.00 |
August | 0.211962E+10 | -.160536E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -514257906.5 | 58.99 | 0.00 | 0.00 |
September | 0.209854E+10 | -.160074E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -497800103.1 | 58.99 | 0.00 | 0.00 |
October | 0.228855E+10 | -.176387E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -524684327.1 | 58.99 | 0.00 | 0.00 |
November | 0.237404E+10 | -.185068E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -523359474.7 | 58.99 | 0.00 | 0.00 |
December | 0.262393E+10 | -.206167E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -562260474.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.283278E+11 | -.220551E+11 | 8760.00 | -.627270E+10 | 58.99 | |||||
Minimum of Months | 0.207519E+10 | -.214515E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -573273481.5 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.271724E+10 | -.156101E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -497660277.5 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 290.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 351.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 407.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 411.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 390.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 293.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 285.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4071.00 | ||||||||||
Minimum of Months | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.135810E+11 | 55768.36 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.790452E+10 | 55768.36 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.122541E+10 | 55768.36 | 06-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.284226E+09 | 55768.36 | 06-APR-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.145703E+09 | 44928.49 | 26-OCT-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.166962E+10 | 55768.36 | 14-NOV-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.648825E+10 | 55768.36 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.312987E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.135810E+11 | 55768.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.398562E+11 | 270401.33 | 06-JAN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.210772E+11 | 270401.33 | 04-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.173939E+10 | 180217.84 | 19-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.475423E+09 | 179193.55 | 06-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.314074E+09 | 178308.64 | 26-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.395294E+10 | 214193.98 | 22-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.167979E+11 | 270401.33 | 04-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.842131E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.398562E+11 | 270401.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.426736E+10 | 35341.28 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.257084E+10 | 35341.28 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.404338E+09 | 35341.28 | 18-MAR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.146675E+09 | 22295.19 | 06-APR-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 247372.48 | 412.29 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 73208090.34 | 10357.59 | 31-OCT-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.418080E+09 | 35341.28 | 21-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.183973E+10 | 35341.28 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.972048E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.426736E+10 | 35341.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.639963E+10 | 30556.99 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.399236E+10 | 30556.99 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.911176E+09 | 30556.99 | 06-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.303156E+09 | 30556.99 | 06-APR-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14482921.65 | 2276.87 | 11-MAY-05:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.210801E+09 | 30008.51 | 31-OCT-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.854812E+09 | 30556.99 | 21-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.307296E+10 | 30556.99 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.157594E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.639963E+10 | 30556.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.154683E+11 | 45254.01 | 07-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.900147E+10 | 45331.80 | 11-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.325969E+10 | 26331.11 | 22-MAR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.890368E+09 | 18768.79 | 05-APR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 21177128.70 | 2692.23 | 10-MAY-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 49929424.21 | 2929.21 | 28-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.141788E+10 | 16953.01 | 25-OCT-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.341558E+10 | 26761.87 | 20-NOV-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.906219E+10 | 32815.06 | 17-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.425866E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.154683E+11 | 45331.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 58788604.32 | 45500669.19 | 2825.72 | 20-JAN-15:30 | 2058.59 | 0.00 |
February | 0.00 | 0.00 | 0.707570E+09 | 0.680538E+09 | 8109.53 | 28-FEB-15:10 | 7845.53 | 0.00 |
March | 0.00 | 0.00 | 0.393265E+10 | 0.323981E+10 | 19932.99 | 30-MAR-21:20 | 17457.13 | 0.00 |
April | 0.00 | 0.00 | 0.934744E+10 | 0.774099E+10 | 17250.30 | 19-APR-14:50 | 14136.45 | 0.00 |
May | 0.00 | 0.00 | 0.189391E+11 | 0.146698E+11 | 23429.39 | 30-MAY-21:40 | 16852.45 | 0.00 |
June | 0.00 | 0.00 | 0.304710E+11 | 0.229271E+11 | 45130.73 | 28-JUN-20:43 | 31766.42 | 0.00 |
July | 0.00 | 0.00 | 0.365158E+11 | 0.260648E+11 | 46171.90 | 26-JUL-20:43 | 29002.62 | 0.00 |
August | 0.00 | 0.00 | 0.391503E+11 | 0.272807E+11 | 46441.80 | 22-AUG-22:03 | 28152.34 | 0.00 |
September | 0.00 | 0.00 | 0.237564E+11 | 0.172021E+11 | 45125.31 | 06-SEP-20:10 | 31871.33 | 0.00 |
October | 0.00 | 0.00 | 0.918697E+10 | 0.693791E+10 | 27680.23 | 18-OCT-21:00 | 17078.75 | 0.00 |
November | 0.00 | 0.00 | 0.270253E+10 | 0.216182E+10 | 12653.77 | 04-NOV-16:00 | 8486.64 | 0.00 |
December | 0.00 | 0.00 | 0.478999E+09 | 0.332343E+09 | 8488.01 | 13-DEC-13:00 | 5587.03 | 0.00 |
Annual Sum or Average | 0.175248E+12 | 0.129283E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 58788604.32 | 45500669.19 | 2825.72 | 2058.59 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.391503E+11 | 0.272807E+11 | 46441.80 | 31871.33 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.125539E+10 | 0.960516E+09 | 29861.31 | 31-JAN-15:10 | 25419.48 | 0.00 |
February | 0.00 | 0.00 | 0.780621E+10 | 0.730214E+10 | 54060.15 | 28-FEB-15:10 | 52023.36 | 0.00 |
March | 0.00 | 0.00 | 0.300028E+11 | 0.249864E+11 | 94206.26 | 29-MAR-20:20 | 77461.45 | 0.00 |
April | 0.00 | 0.00 | 0.608525E+11 | 0.500483E+11 | 106830.09 | 21-APR-22:33 | 77245.08 | 0.00 |
May | 0.00 | 0.00 | 0.107094E+12 | 0.803004E+11 | 143348.18 | 19-MAY-20:43 | 121167.93 | 0.00 |
June | 0.00 | 0.00 | 0.155454E+12 | 0.110968E+12 | 214500.46 | 29-JUN-20:10 | 147834.09 | 0.00 |
July | 0.00 | 0.00 | 0.182270E+12 | 0.120571E+12 | 221901.97 | 26-JUL-20:43 | 125217.95 | 0.00 |
August | 0.00 | 0.00 | 0.195257E+12 | 0.125669E+12 | 224045.30 | 08-AUG-20:10 | 122678.75 | 0.00 |
September | 0.00 | 0.00 | 0.123941E+12 | 0.843951E+11 | 218509.78 | 06-SEP-20:10 | 137131.86 | 0.00 |
October | 0.00 | 0.00 | 0.541072E+11 | 0.399144E+11 | 147850.81 | 18-OCT-21:00 | 82909.59 | 0.00 |
November | 0.00 | 0.00 | 0.191617E+11 | 0.153484E+11 | 71917.42 | 03-NOV-20:20 | 51523.48 | 0.00 |
December | 0.00 | 0.00 | 0.401120E+10 | 0.286331E+10 | 52493.92 | 12-DEC-14:00 | 37728.23 | 0.00 |
Annual Sum or Average | 0.941212E+12 | 0.663327E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.125539E+10 | 0.960516E+09 | 29861.31 | 25419.48 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.195257E+12 | 0.125669E+12 | 224045.30 | 147834.09 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.596783E+09 | 0.527148E+09 | 6029.47 | 31-JAN-14:40 | 5367.84 | 0.00 |
February | 0.00 | 0.00 | 0.215705E+10 | 0.207619E+10 | 10188.53 | 28-FEB-15:30 | 10064.03 | 0.00 |
March | 0.00 | 0.00 | 0.548444E+10 | 0.485337E+10 | 18936.03 | 30-MAR-20:43 | 16584.99 | 0.00 |
April | 0.00 | 0.00 | 0.803756E+10 | 0.689854E+10 | 13469.65 | 16-APR-18:10 | 13161.40 | 0.00 |
May | 0.00 | 0.00 | 0.135604E+11 | 0.106707E+11 | 20673.76 | 30-MAY-20:10 | 14354.42 | 0.00 |
June | 0.00 | 0.00 | 0.203751E+11 | 0.153340E+11 | 27453.45 | 25-JUN-19:23 | 20033.38 | 0.00 |
July | 0.00 | 0.00 | 0.242545E+11 | 0.171789E+11 | 28410.49 | 26-JUL-20:43 | 17531.17 | 0.00 |
August | 0.00 | 0.00 | 0.269657E+11 | 0.187394E+11 | 28465.10 | 22-AUG-22:03 | 17363.85 | 0.00 |
September | 0.00 | 0.00 | 0.179457E+11 | 0.132528E+11 | 27700.34 | 06-SEP-20:08 | 19432.17 | 0.00 |
October | 0.00 | 0.00 | 0.102289E+11 | 0.833880E+10 | 24954.03 | 10-OCT-20:43 | 18582.57 | 0.00 |
November | 0.00 | 0.00 | 0.521375E+10 | 0.463393E+10 | 18187.97 | 12-NOV-19:10 | 18187.97 | 0.00 |
December | 0.00 | 0.00 | 0.201224E+10 | 0.178728E+10 | 11999.70 | 12-DEC-14:00 | 9708.30 | 0.00 |
Annual Sum or Average | 0.136832E+12 | 0.104291E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.596783E+09 | 0.527148E+09 | 6029.47 | 5367.84 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.269657E+11 | 0.187394E+11 | 28465.10 | 20033.38 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.151840E+09 | 0.134061E+09 | 3476.79 | 31-JAN-14:40 | 2974.03 | 0.00 |
February | 0.00 | 0.00 | 0.112087E+10 | 0.110833E+10 | 7854.21 | 28-FEB-15:30 | 7653.93 | 0.00 |
March | 0.00 | 0.00 | 0.301152E+10 | 0.256202E+10 | 14796.63 | 30-MAR-20:43 | 12549.91 | 0.00 |
April | 0.00 | 0.00 | 0.506537E+10 | 0.421239E+10 | 11330.92 | 16-APR-18:10 | 10795.98 | 0.00 |
May | 0.00 | 0.00 | 0.970100E+10 | 0.733207E+10 | 17333.32 | 30-MAY-20:10 | 11256.84 | 0.00 |
June | 0.00 | 0.00 | 0.163139E+11 | 0.117687E+11 | 24041.91 | 28-JUN-20:43 | 15832.03 | 0.00 |
July | 0.00 | 0.00 | 0.199712E+11 | 0.135350E+11 | 24934.47 | 26-JUL-20:43 | 14355.10 | 0.00 |
August | 0.00 | 0.00 | 0.225639E+11 | 0.149501E+11 | 24965.34 | 11-AUG-20:43 | 14249.88 | 0.00 |
September | 0.00 | 0.00 | 0.139307E+11 | 0.980927E+10 | 24317.73 | 06-SEP-20:08 | 16087.38 | 0.00 |
October | 0.00 | 0.00 | 0.708302E+10 | 0.552896E+10 | 21498.82 | 10-OCT-20:43 | 15140.83 | 0.00 |
November | 0.00 | 0.00 | 0.287850E+10 | 0.248523E+10 | 9222.36 | 05-NOV-14:00 | 6633.15 | 0.00 |
December | 0.00 | 0.00 | 0.857754E+09 | 0.717527E+09 | 9236.03 | 12-DEC-14:00 | 7117.59 | 0.00 |
Annual Sum or Average | 0.102650E+12 | 0.741437E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.151840E+09 | 0.134061E+09 | 3476.79 | 2974.03 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.225639E+11 | 0.149501E+11 | 24965.34 | 16087.38 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.466075E+10 | 0.54 | 2988.45 | 01-JAN-07:01 | 0.93 |
February | 0.362656E+10 | 0.47 | 2988.45 | 01-FEB-05:01 | 0.93 |
March | 0.303309E+10 | 0.35 | 2988.45 | 01-MAR-08:70 | 0.93 |
April | 0.150292E+10 | 0.18 | 2988.45 | 01-APR-07:10 | 0.93 |
May | 0.451780E+09 | 0.05 | 2988.45 | 01-MAY-07:05 | 0.92 |
June | 37056720.35 | 0.00 | 2988.45 | 07-JUN-07:10 | 0.92 |
July | 0.103315E+09 | 0.01 | 2988.45 | 28-JUL-11:10 | 0.91 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 |
September | 0.316307E+09 | 0.04 | 2988.45 | 13-SEP-07:09 | 0.92 |
October | 0.195919E+10 | 0.23 | 2988.45 | 01-OCT-07:10 | 0.92 |
November | 0.305573E+10 | 0.37 | 2988.45 | 01-NOV-04:03 | 0.93 |
December | 0.421057E+10 | 0.49 | 2988.45 | 01-DEC-05:01 | 0.93 |
Annual Sum or Average | 0.229573E+11 | 0.23 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.466075E+10 | 0.54 | 2988.45 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.381424E+10 | 0.59 | 2318.85 | 01-JAN-09:03 | 0.93 |
February | 0.344014E+10 | 0.59 | 2318.85 | 01-FEB-12:20 | 0.93 |
March | 0.379725E+10 | 0.58 | 2318.85 | 01-MAR-07:00 | 0.93 |
April | 0.363764E+10 | 0.57 | 2318.85 | 01-APR-11:50 | 0.93 |
May | 0.380945E+10 | 0.62 | 2318.85 | 01-MAY-08:27 | 0.92 |
June | 0.389481E+10 | 0.76 | 2318.85 | 01-JUN-06:50 | 0.92 |
July | 0.407284E+10 | 0.80 | 2318.85 | 01-JUL-05:20 | 0.92 |
August | 0.417640E+10 | 0.83 | 2318.85 | 01-AUG-07:20 | 0.92 |
September | 0.380384E+10 | 0.71 | 2318.85 | 01-SEP-05:50 | 0.92 |
October | 0.373313E+10 | 0.57 | 2318.85 | 01-OCT-08:28 | 0.92 |
November | 0.359850E+10 | 0.56 | 2318.85 | 04-NOV-08:50 | 0.92 |
December | 0.378459E+10 | 0.58 | 2318.85 | 01-DEC-07:10 | 0.93 |
Annual Sum or Average | 0.455628E+11 | 0.65 | |||
Minimum of Months | 0.344014E+10 | 0.56 | 2318.85 | 0.92 | |
Maximum of Months | 0.417640E+10 | 0.83 | 2318.85 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.256136E+11 | 0.94 | 15987.84 | 13-JAN-19:10 | 1.58 |
February | 0.232590E+11 | 0.95 | 15987.84 | 02-FEB-09:00 | 1.57 |
March | 0.261611E+11 | 0.98 | 15987.84 | 16-MAR-15:40 | 1.57 |
April | 0.253341E+11 | 1.00 | 15987.84 | 15-APR-08:20 | 1.57 |
May | 0.267271E+11 | 1.11 | 15987.84 | 04-MAY-08:13 | 1.56 |
June | 0.267747E+11 | 1.25 | 15987.84 | 01-JUN-05:50 | 1.55 |
July | 0.276383E+11 | 1.29 | 15987.84 | 01-JUL-05:05 | 1.55 |
August | 0.282799E+11 | 1.35 | 15987.84 | 08-AUG-05:30 | 1.55 |
September | 0.263601E+11 | 1.22 | 15987.84 | 01-SEP-06:30 | 1.55 |
October | 0.259425E+11 | 1.01 | 15987.84 | 01-OCT-07:20 | 1.55 |
November | 0.247178E+11 | 0.94 | 15987.84 | 02-NOV-18:20 | 1.56 |
December | 0.256717E+11 | 0.94 | 15987.84 | 03-DEC-14:40 | 1.58 |
Annual Sum or Average | 0.312480E+12 | 1.08 | |||
Minimum of Months | 0.232590E+11 | 0.94 | 15987.84 | 1.55 | |
Maximum of Months | 0.282799E+11 | 1.35 | 15987.84 | 1.58 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.233347E+10 | 0.61 | 1437.76 | 02-JAN-06:50 | 0.97 |
February | 0.211455E+10 | 0.61 | 1437.76 | 02-FEB-10:00 | 0.97 |
March | 0.235795E+10 | 0.62 | 1437.76 | 02-MAR-13:50 | 0.97 |
April | 0.227337E+10 | 0.63 | 1437.76 | 01-APR-12:50 | 0.97 |
May | 0.239135E+10 | 0.71 | 1437.76 | 01-MAY-10:47 | 0.96 |
June | 0.244206E+10 | 0.84 | 1437.76 | 01-JUN-10:00 | 0.96 |
July | 0.254434E+10 | 0.86 | 1437.76 | 01-JUL-17:03 | 0.96 |
August | 0.262877E+10 | 0.89 | 1437.76 | 01-AUG-15:50 | 0.96 |
September | 0.241549E+10 | 0.82 | 1437.76 | 02-SEP-08:00 | 0.96 |
October | 0.236484E+10 | 0.69 | 1437.76 | 01-OCT-15:30 | 0.96 |
November | 0.223157E+10 | 0.60 | 1437.76 | 02-NOV-17:03 | 0.96 |
December | 0.232513E+10 | 0.61 | 1437.76 | 01-DEC-06:20 | 0.97 |
Annual Sum or Average | 0.284229E+11 | 0.71 | |||
Minimum of Months | 0.211455E+10 | 0.60 | 1437.76 | 0.96 | |
Maximum of Months | 0.262877E+10 | 0.89 | 1437.76 | 0.97 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.194754E+10 | 0.62 | 1192.42 | 01-JAN-12:03 | 0.96 |
February | 0.176138E+10 | 0.62 | 1192.42 | 01-FEB-07:20 | 0.97 |
March | 0.195297E+10 | 0.61 | 1192.42 | 01-MAR-06:40 | 0.97 |
April | 0.187612E+10 | 0.61 | 1192.42 | 01-APR-12:20 | 0.97 |
May | 0.195916E+10 | 0.65 | 1192.42 | 01-MAY-09:40 | 0.96 |
June | 0.199291E+10 | 0.79 | 1192.42 | 01-JUN-06:10 | 0.96 |
July | 0.208386E+10 | 0.83 | 1192.42 | 01-JUL-05:10 | 0.96 |
August | 0.216238E+10 | 0.88 | 1192.42 | 01-AUG-05:40 | 0.95 |
September | 0.197806E+10 | 0.78 | 1192.42 | 01-SEP-06:00 | 0.96 |
October | 0.194488E+10 | 0.65 | 1192.42 | 01-OCT-10:10 | 0.95 |
November | 0.184801E+10 | 0.59 | 1192.42 | 01-NOV-05:15 | 0.97 |
December | 0.193529E+10 | 0.61 | 1192.42 | 01-DEC-07:57 | 0.97 |
Annual Sum or Average | 0.234426E+11 | 0.69 | |||
Minimum of Months | 0.176138E+10 | 0.59 | 1192.42 | 0.95 | |
Maximum of Months | 0.216238E+10 | 0.88 | 1192.42 | 0.97 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.89 | 0.00 |
February | 0.80 | 0.00 |
March | 0.10 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.22 | 0.00 |
December | 0.74 | 0.00 |
Annual Sum or Average | 3.74 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.89 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.06 | 0.00 |
February | 0.21 | 0.00 |
March | 0.51 | 0.00 |
April | 0.08 | 0.00 |
May | 0.08 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.61 | 0.00 |
November | 0.90 | 0.00 |
December | 0.31 | 14.10 |
Annual Sum or Average | 2.76 | 1.56 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.90 | 14.10 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.37 | 0.00 |
February | 0.09 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.18 | 0.00 |
Annual Sum or Average | 0.64 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.37 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.66 | 0.00 |
February | 0.19 | 0.00 |
March | 0.04 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.36 | 0.00 |
Annual Sum or Average | 1.24 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.66 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 48.14 | 0.00 |
February | 43.79 | 0.00 |
March | 31.13 | 0.00 |
April | 28.19 | 0.00 |
May | 17.57 | 0.00 |
June | 6.23 | 0.00 |
July | 7.03 | 0.00 |
August | 3.85 | 0.00 |
September | 12.35 | 0.00 |
October | 20.18 | 0.00 |
November | 31.29 | 0.00 |
December | 36.28 | 0.00 |
Annual Sum or Average | 286.01 | 0.00 |
Minimum of Months | 3.85 | 0.00 |
Maximum of Months | 48.14 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.383312E+10 | 0.169762E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.366738E+10 | 0.988066E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.503603E+10 | 0.153176E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.659135E+10 | 0.355283E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.972412E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.135292E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.155857E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.164092E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.111645E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.656726E+10 | 0.182128E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.444164E+10 | 0.208702E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.393437E+10 | 0.811032E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.100484E+12 | 0.391234E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.366738E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.164092E+11 | 0.169762E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.260195E+11 | 0.502917E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.257691E+11 | 0.265959E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.356561E+11 | 0.219482E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.446191E+11 | 0.599903E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.603193E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.758571E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.847299E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.888592E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.648648E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.427727E+11 | 0.396308E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.307540E+11 | 0.498793E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.269399E+11 | 0.211961E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.607161E+12 | 0.106263E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.257691E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.888592E+11 | 0.502917E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.250898E+10 | 0.533420E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.273603E+10 | 0.321355E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.394088E+10 | 0.505423E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.462635E+10 | 0.183344E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.634431E+10 | 309215.60 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.846856E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.968213E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.104660E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.757465E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.525570E+10 | 91510112.92 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.371152E+10 | 0.522600E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.290397E+10 | 0.229966E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.682190E+11 | 0.121506E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.250898E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.104660E+11 | 0.533420E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.199288E+10 | 0.799954E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.208700E+10 | 0.499046E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.283303E+10 | 0.113897E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.338174E+10 | 0.378945E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.481454E+10 | 18103652.07 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.682383E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.795534E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.870997E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.599594E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.395531E+10 | 0.263501E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.267201E+10 | 0.106851E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.218368E+10 | 0.384120E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.534053E+11 | 0.196992E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.199288E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.870997E+10 | 0.799954E+10 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.381424E+10 | 58788604.32 | 0.135810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.344014E+10 | 0.707570E+09 | 0.790452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.379725E+10 | 0.393265E+10 | 0.122541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.363764E+10 | 0.934744E+10 | 0.284226E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.380945E+10 | 0.189391E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.389481E+10 | 0.304710E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.407284E+10 | 0.365158E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.417640E+10 | 0.391503E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.380384E+10 | 0.237564E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.373313E+10 | 0.918697E+10 | 0.145703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.359850E+10 | 0.270253E+10 | 0.166962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.378459E+10 | 0.478999E+09 | 0.648825E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.455628E+11 | 0.175248E+12 | 0.312987E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.344014E+10 | 58788604.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.417640E+10 | 0.391503E+11 | 0.135810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.256136E+11 | 0.125539E+10 | 0.398562E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.232590E+11 | 0.780621E+10 | 0.210772E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.261611E+11 | 0.300028E+11 | 0.173939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.253341E+11 | 0.608525E+11 | 0.475423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.267271E+11 | 0.107094E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.267747E+11 | 0.155454E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.276383E+11 | 0.182270E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.282799E+11 | 0.195257E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.263601E+11 | 0.123941E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.259425E+11 | 0.541072E+11 | 0.314074E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.247178E+11 | 0.191617E+11 | 0.395294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.256717E+11 | 0.401120E+10 | 0.167979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.312480E+12 | 0.941212E+12 | 0.842131E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.232590E+11 | 0.125539E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.282799E+11 | 0.195257E+12 | 0.398562E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.233347E+10 | 0.596783E+09 | 0.426736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.211455E+10 | 0.215705E+10 | 0.257084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.235795E+10 | 0.548444E+10 | 0.404338E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.227337E+10 | 0.803756E+10 | 0.146675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.239135E+10 | 0.135604E+11 | 247372.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.244206E+10 | 0.203751E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.254434E+10 | 0.242545E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.262877E+10 | 0.269657E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.241549E+10 | 0.179457E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.236484E+10 | 0.102289E+11 | 73208090.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.223157E+10 | 0.521375E+10 | 0.418080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232513E+10 | 0.201224E+10 | 0.183973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.284229E+11 | 0.136832E+12 | 0.972048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.211455E+10 | 0.596783E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.262877E+10 | 0.269657E+11 | 0.426736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.194754E+10 | 0.151840E+09 | 0.639963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176138E+10 | 0.112087E+10 | 0.399236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.195297E+10 | 0.301152E+10 | 0.911176E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.187612E+10 | 0.506537E+10 | 0.303156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.195916E+10 | 0.970100E+10 | 14482921.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199291E+10 | 0.163139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.208386E+10 | 0.199712E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.216238E+10 | 0.225639E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.197806E+10 | 0.139307E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194488E+10 | 0.708302E+10 | 0.210801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.184801E+10 | 0.287850E+10 | 0.854812E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.193529E+10 | 0.857754E+09 | 0.307296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.234426E+11 | 0.102650E+12 | 0.157594E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.176138E+10 | 0.151840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.216238E+10 | 0.225639E+11 | 0.639963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.381424E+10 | 0.00 | 0.00 | 0.00 | 18886382.30 | 0.00 | 0.169762E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.344014E+10 | 0.00 | 0.00 | 0.00 | 0.227238E+09 | 0.00 | 0.988066E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.379725E+10 | 0.00 | 0.00 | 0.00 | 0.123878E+10 | 0.00 | 0.153176E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.363764E+10 | 0.00 | 0.00 | 0.00 | 0.295371E+10 | 0.00 | 0.355283E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.380945E+10 | 0.00 | 0.00 | 0.00 | 0.591467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.389481E+10 | 0.00 | 0.00 | 0.00 | 0.963441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.407284E+10 | 0.00 | 0.00 | 0.00 | 0.115129E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.417640E+10 | 0.00 | 0.00 | 0.00 | 0.122328E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.380384E+10 | 0.00 | 0.00 | 0.00 | 0.736064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.373313E+10 | 0.00 | 0.00 | 0.00 | 0.283412E+10 | 0.00 | 0.182128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.359850E+10 | 0.00 | 0.00 | 0.00 | 0.843137E+09 | 0.00 | 0.208702E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.378459E+10 | 0.00 | 0.00 | 0.00 | 0.149780E+09 | 0.00 | 0.811032E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.455628E+11 | 0.00 | 0.00 | 0.00 | 0.549210E+11 | 0.00 | 0.391234E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.344014E+10 | 0.00 | 0.00 | 0.00 | 18886382.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.417640E+10 | 0.00 | 0.00 | 0.00 | 0.122328E+11 | 0.00 | 0.169762E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.256136E+11 | 0.00 | 0.00 | 0.00 | 0.405866E+09 | 0.00 | 0.502917E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.232590E+11 | 0.00 | 0.00 | 0.00 | 0.251015E+10 | 0.00 | 0.265959E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.261611E+11 | 0.00 | 0.00 | 0.00 | 0.949505E+10 | 0.00 | 0.219482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.253341E+11 | 0.00 | 0.00 | 0.00 | 0.192851E+11 | 0.00 | 0.599903E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.267271E+11 | 0.00 | 0.00 | 0.00 | 0.335922E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.267747E+11 | 0.00 | 0.00 | 0.00 | 0.490825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.276383E+11 | 0.00 | 0.00 | 0.00 | 0.570917E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.282799E+11 | 0.00 | 0.00 | 0.00 | 0.605793E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.263601E+11 | 0.00 | 0.00 | 0.00 | 0.385048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.259425E+11 | 0.00 | 0.00 | 0.00 | 0.168302E+11 | 0.00 | 0.396308E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.247178E+11 | 0.00 | 0.00 | 0.00 | 0.603621E+10 | 0.00 | 0.498793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.256717E+11 | 0.00 | 0.00 | 0.00 | 0.126817E+10 | 0.00 | 0.211961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.312480E+12 | 0.00 | 0.00 | 0.00 | 0.294681E+12 | 0.00 | 0.106263E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.232590E+11 | 0.00 | 0.00 | 0.00 | 0.405866E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.282799E+11 | 0.00 | 0.00 | 0.00 | 0.605793E+11 | 0.00 | 0.502917E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.233347E+10 | 0.00 | 0.00 | 0.00 | 0.175503E+09 | 0.00 | 0.533420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.211455E+10 | 0.00 | 0.00 | 0.00 | 0.621481E+09 | 0.00 | 0.321355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.235795E+10 | 0.00 | 0.00 | 0.00 | 0.158293E+10 | 0.00 | 0.505423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.227337E+10 | 0.00 | 0.00 | 0.00 | 0.235297E+10 | 0.00 | 0.183344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.239135E+10 | 0.00 | 0.00 | 0.00 | 0.395296E+10 | 0.00 | 309215.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.244206E+10 | 0.00 | 0.00 | 0.00 | 0.602650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.254434E+10 | 0.00 | 0.00 | 0.00 | 0.713779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.262877E+10 | 0.00 | 0.00 | 0.00 | 0.783718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.241549E+10 | 0.00 | 0.00 | 0.00 | 0.515916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.236484E+10 | 0.00 | 0.00 | 0.00 | 0.289087E+10 | 0.00 | 91510112.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.223157E+10 | 0.00 | 0.00 | 0.00 | 0.147995E+10 | 0.00 | 0.522600E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232513E+10 | 0.00 | 0.00 | 0.00 | 0.578842E+09 | 0.00 | 0.229966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.284229E+11 | 0.00 | 0.00 | 0.00 | 0.397961E+11 | 0.00 | 0.121506E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.211455E+10 | 0.00 | 0.00 | 0.00 | 0.175503E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.262877E+10 | 0.00 | 0.00 | 0.00 | 0.783718E+10 | 0.00 | 0.533420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.194754E+10 | 0.00 | 0.00 | 0.00 | 45343501.29 | 0.00 | 0.799954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176138E+10 | 0.00 | 0.00 | 0.00 | 0.325612E+09 | 0.00 | 0.499046E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.195297E+10 | 0.00 | 0.00 | 0.00 | 0.880058E+09 | 0.00 | 0.113897E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.187612E+10 | 0.00 | 0.00 | 0.00 | 0.150562E+10 | 0.00 | 0.378945E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.195916E+10 | 0.00 | 0.00 | 0.00 | 0.285538E+10 | 0.00 | 18103652.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199291E+10 | 0.00 | 0.00 | 0.00 | 0.483092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.208386E+10 | 0.00 | 0.00 | 0.00 | 0.587147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.216238E+10 | 0.00 | 0.00 | 0.00 | 0.654760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.197806E+10 | 0.00 | 0.00 | 0.00 | 0.401788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194488E+10 | 0.00 | 0.00 | 0.00 | 0.201044E+10 | 0.00 | 0.263501E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.184801E+10 | 0.00 | 0.00 | 0.00 | 0.823992E+09 | 0.00 | 0.106851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.193529E+10 | 0.00 | 0.00 | 0.00 | 0.248397E+09 | 0.00 | 0.384120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.234426E+11 | 0.00 | 0.00 | 0.00 | 0.299627E+11 | 0.00 | 0.196992E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.176138E+10 | 0.00 | 0.00 | 0.00 | 45343501.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.216238E+10 | 0.00 | 0.00 | 0.00 | 0.654760E+10 | 0.00 | 0.799954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.181608E+10 | 0.00 | 0.00 | 50141.07 | 0.00 | 0.848032E+10 | 0.119227E+09 | 0.00 | 0.28 |
February | 0.225431E+10 | 0.00 | 0.00 | 873641.87 | 0.00 | 0.481565E+10 | 0.586140E+09 | 0.00 | 0.28 |
March | 0.300695E+10 | 88346393.78 | 0.00 | 3966872.67 | 0.00 | 0.813684E+09 | 0.179847E+10 | 0.00 | 0.28 |
April | 0.133898E+10 | 0.341282E+09 | 0.00 | 6334137.58 | 964409.25 | 0.226168E+09 | 0.144908E+10 | 0.00 | 0.28 |
May | 0.423885E+09 | 0.209579E+10 | 0.00 | 5528729.37 | 546525.54 | 0.00 | 0.645704E+09 | 0.00 | 0.28 |
June | 87060126.14 | 0.623772E+10 | 0.00 | 3393487.87 | 8132172.59 | 0.00 | 0.247006E+09 | 0.00 | 0.30 |
July | 30972.09 | 0.910008E+10 | 0.00 | 249395.25 | 9619430.29 | 0.00 | 21554353.63 | 0.00 | 0.30 |
August | 0.00 | 0.102647E+11 | 0.00 | 92287.23 | 6293981.18 | 0.00 | 5383342.81 | 0.00 | 0.31 |
September | 0.184751E+09 | 0.430277E+10 | 0.00 | 3903375.97 | 6204425.62 | 0.00 | 0.385620E+09 | 0.00 | 0.29 |
October | 0.205575E+10 | 0.895609E+09 | 0.00 | 6630980.54 | 660693.55 | 0.122876E+09 | 0.196166E+10 | 0.00 | 0.28 |
November | 0.327475E+10 | 27357395.47 | 1838749.44 | 3267022.74 | 8503210.24 | 0.109552E+10 | 0.156151E+10 | 33489.68 | 0.27 |
December | 0.401648E+10 | 0.00 | 0.00 | 573543.44 | 0.00 | 0.394926E+10 | 0.248345E+09 | 0.00 | 0.28 |
Annual Sum or Average | 0.184590E+11 | 0.333537E+11 | 1838749.44 | 34863615.61 | 40924848.26 | 0.195035E+11 | 0.902970E+10 | 33489.68 | 0.28 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 50141.07 | 0.00 | 0.00 | 5383342.81 | 0.00 | 0.27 |
Maximum of Months | 0.401648E+10 | 0.102647E+11 | 1838749.44 | 6630980.54 | 9619430.29 | 0.848032E+10 | 0.196166E+10 | 33489.68 | 0.31 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.590399E+11 | 0.00 | 0.00 | 2251280.74 | 0.00 | 0.204719E+11 | 0.247232E+10 | 0.00 | 0.54 |
February | 0.411855E+11 | 0.00 | 0.00 | 14243197.69 | 0.00 | 0.102988E+11 | 0.874894E+10 | 0.00 | 0.54 |
March | 0.225832E+11 | 0.118022E+10 | 0.00 | 41714709.57 | 3135607.17 | 0.164995E+09 | 0.209484E+11 | 0.00 | 0.56 |
April | 0.998683E+10 | 0.453447E+10 | 0.00 | 46950498.45 | 0.00 | 32180645.89 | 0.125850E+11 | 0.00 | 0.56 |
May | 0.252273E+10 | 0.190286E+11 | 0.00 | 33227544.47 | 56418700.45 | 0.00 | 0.441686E+10 | 0.00 | 0.57 |
June | 0.842128E+09 | 0.510935E+11 | 0.00 | 13738995.86 | 0.240725E+09 | 0.00 | 0.132135E+10 | 0.00 | 0.59 |
July | 0.00 | 0.713842E+11 | 0.00 | 1502761.40 | 0.474836E+09 | 0.00 | 0.108440E+09 | 0.00 | 0.59 |
August | 0.00 | 0.802597E+11 | 0.00 | 289786.02 | 0.415812E+09 | 0.00 | 32179416.63 | 0.00 | 0.60 |
September | 0.124592E+10 | 0.347810E+11 | 0.00 | 19541846.16 | 0.141079E+09 | 0.00 | 0.283836E+10 | 0.00 | 0.58 |
October | 0.152981E+11 | 0.793236E+10 | 0.00 | 45923207.24 | 21120269.37 | 24521468.36 | 0.156751E+11 | 0.00 | 0.55 |
November | 0.299102E+11 | 0.426851E+09 | 0.00 | 27758684.07 | 51888922.77 | 0.142949E+10 | 0.147682E+11 | 0.00 | 0.54 |
December | 0.519532E+11 | 145516.81 | 0.00 | 7249813.92 | 0.00 | 0.794524E+10 | 0.566606E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.234568E+12 | 0.270621E+12 | 0.00 | 0.254392E+09 | 0.140502E+10 | 0.403671E+11 | 0.895813E+11 | 0.00 | 0.56 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 289786.02 | 0.00 | 0.00 | 32179416.63 | 0.00 | 0.54 |
Maximum of Months | 0.590399E+11 | 0.802597E+11 | 0.00 | 46950498.45 | 0.474836E+09 | 0.204719E+11 | 0.209484E+11 | 0.00 | 0.60 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.430659E+10 | 0.00 | 0.00 | 1860522.73 | 0.00 | 0.240943E+10 | 0.130427E+10 | 0.00 | 0.55 |
February | 0.311952E+10 | 0.00 | 0.00 | 4725458.14 | 0.00 | 0.132186E+10 | 0.131625E+10 | 0.00 | 0.55 |
March | 0.157372E+10 | 0.158828E+09 | 0.00 | 8001063.98 | 0.00 | 0.221396E+09 | 0.223211E+10 | 0.00 | 0.56 |
April | 0.869835E+09 | 0.498282E+09 | 0.00 | 6285194.99 | 0.00 | 89926691.44 | 0.115181E+10 | 0.00 | 0.56 |
May | 0.273383E+09 | 0.199210E+10 | 0.00 | 3815226.39 | 561106.86 | 0.00 | 0.448080E+09 | 0.00 | 0.57 |
June | 74427508.00 | 0.517837E+10 | 0.00 | 1832396.21 | 3054727.59 | 0.00 | 0.138910E+09 | 0.00 | 0.60 |
July | 0.00 | 0.739676E+10 | 0.00 | 157201.79 | 3146384.05 | 0.00 | 15646538.40 | 0.00 | 0.60 |
August | 0.00 | 0.849164E+10 | 0.00 | 47071.32 | 837217.46 | 0.00 | 3160613.69 | 0.00 | 0.62 |
September | 83239990.91 | 0.386703E+10 | 0.00 | 2842197.08 | 1238888.85 | 0.00 | 0.274743E+09 | 0.00 | 0.59 |
October | 0.110513E+10 | 0.984930E+09 | 0.00 | 10769906.53 | 0.00 | 18439161.60 | 0.170733E+10 | 0.00 | 0.56 |
November | 0.184219E+10 | 0.115260E+09 | 0.00 | 9256154.22 | 1253029.52 | 0.205855E+09 | 0.231714E+10 | 0.00 | 0.55 |
December | 0.302665E+10 | 13180546.03 | 0.00 | 4469817.69 | 0.00 | 0.113700E+10 | 0.222157E+10 | 0.00 | 0.55 |
Annual Sum or Average | 0.162747E+11 | 0.286964E+11 | 0.00 | 54062211.07 | 10091354.34 | 0.540391E+10 | 0.131310E+11 | 0.00 | 0.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 47071.32 | 0.00 | 0.00 | 3160613.69 | 0.00 | 0.55 |
Maximum of Months | 0.430659E+10 | 0.849164E+10 | 0.00 | 10769906.53 | 3146384.05 | 0.240943E+10 | 0.231714E+10 | 0.00 | 0.62 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.362196E+10 | 0.00 | 0.00 | 406538.72 | 0.00 | 0.396651E+10 | 0.318575E+09 | 0.00 | 0.55 |
February | 0.255950E+10 | 0.00 | 0.00 | 2324407.76 | 0.00 | 0.252381E+10 | 0.614113E+09 | 0.00 | 0.55 |
March | 0.196581E+10 | 0.116326E+09 | 0.00 | 3854402.68 | 0.00 | 0.648997E+09 | 0.137163E+10 | 0.00 | 0.56 |
April | 0.113896E+10 | 0.376128E+09 | 0.00 | 2882980.53 | 163838.07 | 0.193803E+09 | 0.779164E+09 | 0.00 | 0.55 |
May | 0.465165E+09 | 0.168635E+10 | 0.00 | 2223646.77 | 156584.24 | 0.00 | 0.338927E+09 | 0.00 | 0.56 |
June | 0.122041E+09 | 0.476628E+10 | 0.00 | 1067398.10 | 8748889.66 | 0.00 | 93360251.42 | 0.00 | 0.59 |
July | 13687136.19 | 0.684483E+10 | 0.00 | 164725.21 | 9446930.40 | 0.00 | 20628830.18 | 0.00 | 0.59 |
August | 0.00 | 0.794999E+10 | 0.00 | 36583.48 | 473429.40 | 0.00 | 7539968.88 | 0.00 | 0.62 |
September | 0.216198E+09 | 0.345643E+10 | 0.00 | 1794579.60 | 4042038.17 | 0.00 | 0.220521E+09 | 0.00 | 0.59 |
October | 0.151753E+10 | 0.840213E+09 | 0.00 | 6454891.60 | 235785.58 | 0.175756E+09 | 0.113514E+10 | 0.00 | 0.56 |
November | 0.230304E+10 | 59695981.73 | 0.00 | 5038588.82 | 1941938.99 | 0.406227E+09 | 0.159947E+10 | 0.00 | 0.55 |
December | 0.343077E+10 | 4285517.16 | 0.00 | 1777767.99 | 0.00 | 0.190165E+10 | 0.882589E+09 | 0.00 | 0.55 |
Annual Sum or Average | 0.173547E+11 | 0.261005E+11 | 0.00 | 28026511.25 | 25209434.51 | 0.981675E+10 | 0.738166E+10 | 0.00 | 0.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 36583.48 | 0.00 | 0.00 | 7539968.88 | 0.00 | 0.55 |
Maximum of Months | 0.362196E+10 | 0.794999E+10 | 0.00 | 6454891.60 | 9446930.40 | 0.396651E+10 | 0.159947E+10 | 0.00 | 0.62 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:06
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |