Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885
Simulation Timestamp: 2020-06-03 19:19:11
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1628.62 | 779.13 | 779.13 |
Net Site Energy | 1628.62 | 779.13 | 779.13 |
Total Source Energy | 4371.10 | 2091.11 | 2091.11 |
Net Source Energy | 4371.10 | 2091.11 | 2091.11 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 377.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 17.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 704.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 110.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 224.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 65.19 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1250.92 | 377.70 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 377.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 17.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 704.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 110.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 224.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 65.19 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 389.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 147.11 | 180.69 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 598.44 | 180.69 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 389.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 147.11 | 180.69 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 598.44 | 180.69 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1250.922 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1250.922 | 100.00 |
Total On-Site and Utility Electric Sources | 1250.922 | 100.00 |
Total Electricity End Uses | 1250.922 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1056.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19 |
RunPeriod | RUNPERIOD 1 |
Weather File | William R Fairchild WA USA TMY3 WMO#=727885 |
Latitude [deg] | 48.12 |
Longitude [deg] | -123.5 |
Elevation [m] | 91.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 24.9638 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 27.8378 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 18.3225 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0629 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0629 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 22-JUL-15:39 | 10-JAN-08:09 | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 170020.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 30820.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 7564.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 103313.61 | 170020.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 170020.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 30820.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 7564.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 409.43 | 0.00 | 0.00 | 0.00 |
Cooling | 55.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 2230.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 350.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 407.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 712.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 206.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3961.67 | 409.43 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 195.87 | 0.00 | 0.00 | 0.00 |
Cooling | 26.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1066.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 167.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 340.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 98.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1895.25 | 195.87 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 195.87 | 0.00 | 0.00 | 0.00 |
Cooling | 26.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1066.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 167.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 340.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 98.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1895.25 | 195.87 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 1.87 |
SMSTORE1 DIRECT AIR | 1.03 |
SMSTORE2 DIRECT AIR | 1.02 |
SMSTORE3 DIRECT AIR | 1.05 |
SMSTORE4 DIRECT AIR | 1.02 |
LGSTORE2 DIRECT AIR | 1.82 |
SMSTORE5 DIRECT AIR | 0.941592 |
SMSTORE6 DIRECT AIR | 0.933321 |
SMSTORE7 DIRECT AIR | 0.917062 |
SMSTORE8 DIRECT AIR | 0.887270 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 1.87 | 1.87 | 1.87 | 1.87 | 1.87 | 1.87 | 1.00 | 1.00 | 1.87 |
PSZ-AC_2:2 | 1.03 | 1.03 | 1.03 | 1.03 | 1.04 | 1.04 | 1.00 | 0.986049 | 1.04 |
PSZ-AC_3:3 | 1.02 | 1.02 | 1.02 | 1.02 | 1.04 | 1.04 | 1.00 | 0.980662 | 1.04 |
PSZ-AC_4:4 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.00 | 1.00 | 1.05 |
PSZ-AC_5:5 | 1.02 | 1.02 | 1.02 | 1.02 | 1.04 | 1.04 | 1.00 | 0.979385 | 1.04 |
PSZ-AC_6:6 | 1.82 | 1.82 | 1.82 | 1.82 | 1.82 | 1.82 | 1.00 | 1.00 | 1.82 |
PSZ-AC_7:7 | 0.941592 | 0.941592 | 0.941592 | 0.941592 | 0.944634 | 0.944634 | 1.00 | 0.996780 | 0.944634 |
PSZ-AC_8:8 | 0.933321 | 0.933321 | 0.933321 | 0.933321 | 0.936974 | 0.936974 | 1.00 | 0.996101 | 0.936974 |
PSZ-AC_9:9 | 0.917062 | 0.917062 | 0.917062 | 0.917062 | 0.922655 | 0.922655 | 1.00 | 0.993937 | 0.922655 |
PSZ-AC_10:10 | 0.887270 | 0.887270 | 0.887270 | 0.887270 | 0.903171 | 0.903171 | 1.00 | 0.982393 | 0.903171 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 1.87 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 1.04 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 1.04 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 1.05 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 1.04 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 1.82 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 0.944634 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 0.936974 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 0.922655 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 0.903171 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 1.87 | 1.87 | 1.87 | 1.87 | 31032.14 | 54916.77 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.04 | 1.04 | 1.04 | 1.04 | 17275.45 | 29533.43 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.04 | 1.04 | 1.04 | 1.04 | 17281.15 | 29413.92 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 17335.72 | 29945.11 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.04 | 1.04 | 1.04 | 1.04 | 17186.63 | 29257.25 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.82 | 1.82 | 1.82 | 1.82 | 30102.77 | 53646.77 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 0.944634 | 0.944634 | 0.944634 | 0.944634 | 15637.04 | 27555.17 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 0.936974 | 0.936974 | 0.936974 | 0.936974 | 15510.25 | 27368.10 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 0.922655 | 0.922655 | 0.922655 | 0.922655 | 15273.22 | 27000.32 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 0.903171 | 0.903171 | 0.903171 | 0.903171 | 14950.69 | 26326.54 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 1.87 | 0.937325 | 1.87 | 31032.11 | 31032.14 | 15516.07 | 31032.14 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 1.04 | 0.521805 | 1.04 | 17275.45 | 17275.45 | 8637.73 | 17275.45 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.04 | 0.521975 | 1.04 | 17281.08 | 17281.15 | 8640.58 | 17281.15 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 1.05 | 0.523625 | 1.05 | 17335.71 | 17335.72 | 8667.86 | 17335.72 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 1.04 | 0.519120 | 1.04 | 17186.56 | 17186.63 | 8593.32 | 17186.63 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 1.82 | 0.909255 | 1.82 | 30102.80 | 30102.77 | 15051.39 | 30102.77 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 0.944630 | 0.472315 | 0.944630 | 15636.98 | 15637.04 | 7818.52 | 15637.04 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 0.936970 | 0.468485 | 0.936970 | 15510.18 | 15510.25 | 7755.12 | 15510.25 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 0.922660 | 0.461330 | 0.922660 | 15273.30 | 15273.22 | 7636.61 | 15273.22 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 0.903170 | 0.451585 | 0.903170 | 14950.67 | 14950.69 | 7475.35 | 14950.69 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.87 | 2051.82 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.04 | 1189.83 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.04 | 1190.22 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.05 | 1193.98 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.04 | 1183.71 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.82 | 1990.37 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 0.944634 | 1076.99 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 0.936974 | 1068.25 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 0.922655 | 1051.93 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 0.903171 | 1029.71 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 54916.77 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 29533.43 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 29413.92 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 29945.11 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 29257.25 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 53646.77 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 27555.17 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 27368.10 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 27000.32 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 26326.54 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.30 | 6.70 | 4.10 | 4.20 | 4.20 | 5.90 | 9.00 | 10.00 | 13.30 | 15.00 | 15.70 | 13.40 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | William R Fairchild WA USA TMY3 WMO#=727885 | 48.12 | -123.50 | -8.00 | 91.00 | 100237 | 1.1914 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.23 | 11.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 24.964 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.264 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 27.838 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 32.138 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 2313.751 | 6.641 | 77.135 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2313.751 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1657.501 | 9.515 | 110.515 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1657.501 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.3843 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1995 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2888 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.368 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.937 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.386 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
19 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
20 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
21 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
22 | 7 | -0.35963630E-12 | 0.61482467E-15 | -0.13288964E-12 | 0.15093609E-15 |
23 | 6 | 0.33258387E-07 | 0.11249777E-09 | 0.75805110E-08 | -0.16019892E-12 |
24 | 5 | -0.21313350E-03 | 0.93714421E-06 | -0.10927814E-03 | 0.74776115E-08 |
25 | 4 | 0.31870195 | 0.44521373E-03 | 0.10925225 | -0.37358013E-04 |
26 | 3 | -7.7913368 | 0.13499397E-01 | -2.4947666 | 0.31584435E-01 |
27 | 2 | 42.601618 | 0.47079245E-01 | 15.902165 | -0.35261900 |
28 | 1 | -81.870774 | 0.20888078E-01 | -29.712230 | 1.1068570 |
29 | 0 | 46.824331 | 0.41326549E-03 | 16.278015 | |
30 | 7 | -0.21163652E-08 | -0.68723841E-15 | 0.43910983E-14 | -0.57684426E-16 |
31 | 6 | 0.56109385E-05 | 0.38186281E-08 | 0.31898696E-02 | -0.26759299E-04 |
32 | 5 | -0.40164657E-03 | 0.22608617E-05 | -0.22372456 | 0.19561502E-02 |
33 | 4 | 0.92272104E-02 | 0.10289840E-03 | 4.8295456 | -0.45264980E-01 |
34 | 3 | -0.80993241E-01 | 0.81813938E-03 | -38.021416 | 0.39865375 |
35 | 2 | 0.28754352 | 0.13608947E-02 | 116.48395 | -1.4179393 |
36 | 1 | -0.41499682 | 0.41453381E-03 | -143.90731 | 2.0490399 |
37 | 0 | 0.20232414 | 0.10048102E-04 | 60.838472 | |
38 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
39 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
40 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
41 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
42 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
43 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
44 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
45 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
46 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
47 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
48 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
49 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
50 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
51 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
52 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
53 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
54 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
55 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
56 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
57 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
58 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
59 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
60 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
61 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
62 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
63 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
64 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
65 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
66 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
67 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
68 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
69 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
70 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
71 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
72 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
73 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
74 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
75 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
76 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
77 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
78 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
79 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
80 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
81 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
82 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
83 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
84 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
85 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
86 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
87 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
88 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
89 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
90 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
91 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
92 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
93 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
94 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479936E-14 | -0.41635794E-16 |
95 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
96 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
97 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
98 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
99 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
100 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
101 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
102 | 7 | -0.14484255E-08 | -0.22640907E-15 | 0.11860658E-13 | -0.17473455E-15 |
103 | 6 | 0.80640390E-05 | 0.55493782E-08 | 0.31828288E-02 | -0.26700235E-04 |
104 | 5 | -0.58275339E-03 | 0.32892043E-05 | -0.22332434 | 0.19526176E-02 |
105 | 4 | 0.13421983E-01 | 0.14977251E-03 | 4.8228790 | -0.45200897E-01 |
106 | 3 | -0.11791368 | 0.11914425E-02 | -37.983753 | 0.39823745 |
107 | 2 | 0.41875064 | 0.19825898E-02 | 116.41064 | -1.4169588 |
108 | 1 | -0.60444169 | 0.60433957E-03 | -143.86415 | 2.0483306 |
109 | 0 | 0.29470347 | 0.14596444E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 29 | 1 | VerySmooth | 2.672 | 0.394 | 0.315 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.40629E-002 | 0.31435 | 0.46917 | 0.46917 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11822 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.286 | 8.224E-004 | 4.530E-004 | 0.571 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 6.149E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.648E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 0.164 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 7.565E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.204 | 1.172E-003 | 5.440E-004 | 0.815 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 5.921E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 21064.86045 | 25277.83254 | 1.56221 | 1.87465 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 26.40000 | 8.38408E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 23767.34889 | 28520.81867 | 1.03548 | 1.24257 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 11900.06601 | 14280.07921 | 0.85754 | 1.02905 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 12151.89519 | 14582.27423 | 0.52941 | 0.63530 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 11842.69284 | 14211.23141 | 0.85314 | 1.02377 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 12314.65610 | 14777.58732 | 0.53650 | 0.64381 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 11767.66530 | 14121.19837 | 0.87271 | 1.04725 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 26.24833 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 12426.29307 | 14911.55168 | 0.54137 | 0.64964 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 11764.54065 | 14117.44877 | 0.84737 | 1.01684 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 12606.60960 | 15127.93151 | 0.54922 | 0.65907 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 20433.92335 | 24520.70802 | 1.51542 | 1.81851 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 26.17250 | 8.38408E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 23710.78173 | 28452.93808 | 1.03302 | 1.23962 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 10913.35246 | 13096.02296 | 0.78466 | 0.94159 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 12930.81888 | 15516.98266 | 0.56335 | 0.67602 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 10820.13077 | 12984.15693 | 0.77777 | 0.93332 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 12918.70982 | 15502.45179 | 0.56282 | 0.67539 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 10636.85742 | 12764.22890 | 0.76422 | 0.91706 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 13127.86277 | 15753.43533 | 0.57193 | 0.68632 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 10302.09255 | 12362.51105 | 0.73939 | 0.88727 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 14522.91866 | 17427.50239 | 0.63271 | 0.75925 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 26123.73 | 1.87465 | 1.87465 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 40619.95 | 1.24257 | 1.24257 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 14454.65 | 1.04361 | 1.04361 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 20627.06 | 0.63530 | 0.63530 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 14451.27 | 1.04395 | 1.04395 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 20819.53 | 0.64381 | 0.64381 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 14493.76 | 1.04725 | 1.04725 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 20951.54 | 0.64964 | 0.64964 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 14374.42 | 1.03824 | 1.03824 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 21164.77 | 0.65907 | 0.65907 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 25320.87 | 1.81851 | 1.81851 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 40553.10 | 1.23962 | 1.23962 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 13037.01 | 0.94463 | 0.94463 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 21548.17 | 0.67602 | 0.67602 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 12932.91 | 0.93697 | 0.93697 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 21533.85 | 0.67539 | 0.67539 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 12796.63 | 0.92266 | 0.92266 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 21781.17 | 0.68632 | 0.68632 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 12522.86 | 0.90317 | 0.90317 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 23430.83 | 0.75925 | 0.75925 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.87465 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.02905 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.02377 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.04725 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.01684 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.81851 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.94159 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.93332 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.91706 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.88727 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.87465 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.87465 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.87465 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.87465 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.87465 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.87465 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.02905 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.02905 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.02905 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.02905 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04361 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04361 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 0.98605 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.02377 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.02377 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.02377 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.02377 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04395 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04395 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 0.98066 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.04725 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.04725 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.04725 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.04725 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04725 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04725 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.01684 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.01684 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.01684 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.01684 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.03824 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.03824 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 0.97938 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.81851 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.81851 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.81851 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.81851 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.81851 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.81851 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.94159 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.94159 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.94159 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.94159 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.94463 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 0.94463 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 0.99678 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.93332 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.93332 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.93332 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.93332 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.93697 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 0.93697 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 0.99610 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.91706 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.91706 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.91706 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.91706 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92266 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 0.92266 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 0.99394 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.88727 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.88727 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.88727 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.88727 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.90317 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 0.90317 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 0.98239 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 1.87465 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.04361 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.04395 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.04725 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.03824 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.81851 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 0.94463 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 0.93697 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 0.92266 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 0.90317 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.87465 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.87465 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.87465 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.87465 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.87465 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.87465 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.93733 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.87465 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 31032.11389 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 31032.14000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 15516.07000 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 31032.14000 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 31032.14000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 54916.76921 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.87465 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2051.81678 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 54916.76921 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04361 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04361 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04361 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04361 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04361 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04361 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52181 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04361 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17275.45108 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17275.45000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8637.72500 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17275.45000 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17275.45000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29533.43293 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04361 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1189.83022 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29533.43293 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04395 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04395 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04395 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04395 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04395 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04395 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52198 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04395 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17281.07929 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17281.15000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8640.57500 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17281.15000 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17281.15000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29413.91739 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04395 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1190.22280 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29413.91739 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04725 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04725 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04725 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04725 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04725 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04725 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52363 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04725 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17335.70601 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17335.72000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8667.86000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17335.72000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17335.72000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29945.11175 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04725 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1193.98077 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29945.11175 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.03824 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.03824 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.03824 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.03824 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.03824 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.03824 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.51912 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.03824 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17186.55852 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17186.63000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8593.31500 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17186.63000 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17186.63000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29257.25461 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.03824 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1183.71276 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29257.25461 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.81851 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.81851 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.81851 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.81851 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.81851 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.81851 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.90926 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.81851 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 30102.79755 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 30102.77000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 15051.38500 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 30102.77000 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 30102.77000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 53646.77037 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.81851 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1990.36753 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 53646.77037 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.94463 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.94463 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.94463 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.94463 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.94463 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.94463 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.47232 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.94463 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15636.98063 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15637.04000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7818.52000 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15637.04000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15637.04000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27555.17497 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.94463 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1076.98605 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27555.17497 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.93697 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.93697 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.93697 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.93697 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.93697 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.93697 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46849 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.93697 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15510.18043 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15510.25000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7755.12500 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15510.25000 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15510.25000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27368.09658 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.93697 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1068.25336 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27368.09658 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92266 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92266 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92266 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92266 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92266 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92266 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46133 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.92266 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15273.29912 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15273.22000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7636.61000 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15273.22000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15273.22000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27000.31940 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92266 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1051.92844 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27000.31940 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.90317 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.90317 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.90317 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.90317 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.90317 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.90317 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.45159 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.90317 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14950.67042 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 14950.69000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7475.34500 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14950.69000 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 14950.69000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26326.53525 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.90317 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1029.71461 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26326.53525 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 29563.0 | 10.03 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 16457.6 | 30.76 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 16463.0 | 41.76 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 16515.0 | 52.63 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 16373.0 | 64.08 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 28677.6 | 43.37 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14896.7 | 102.61 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14775.9 | 114.46 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 14550.1 | 127.23 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 14242.9 | 140.98 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.199 | 0.190 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.289 | 0.270 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 9 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 2.3903944012E-002 | 0.1416685493 | Pass | Pass | 8.5887320408E-002 | 0.2392749092 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 4.7076907401E-002 | 8.7713687451E-002 | Pass | Pass | 8.4338070015E-002 | 0.2784263130 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 3.3358855928E-002 | 0.1507171979 | Pass | Pass | 6.5566932801E-002 | 0.2140964704 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 3.4821937585E-002 | 0.1632398509 | Pass | Pass | 8.4456178852E-002 | 0.3015474689 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 3.8279751766E-002 | 0.1742523372 | Pass | Pass | 0.1696014374 | 1.0560978529 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 5.0470488984E-002 | 0.2380613244 | Pass | Pass | 7.0461975990E-002 | 0.2313764980 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 5.0561360157E-002 | 0.2371212617 | Pass | Pass | 4.4669261035E-002 | 0.1449489372 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 5.2097878991E-002 | 0.2434404978 | Pass | Pass | 4.1575108062E-002 | 0.1345842183 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 5.7003420393E-002 | 0.2680186741 | Pass | Pass | 3.5797953279E-002 | 0.1152497842 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 8.0028166504E-002 | 0.3503255631 | Pass | Pass | 2.9996428408E-002 | 9.5815316701E-002 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | -4.30 | 0.00 | -4.30 | Wetbulb [C] | 1.20 | 110.00 |
WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40 | 9.10 | 17.00 | Wetbulb [C] | 2.10 | 90.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.199 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.289 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.672 | 0.394 | 0.401 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.672 | 0.394 | 0.401 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 117.88 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 6.6413 | 348.39 | 2313.75 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 42.73 |
SMSTORE1_LIGHTS | SMSTORE1 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 58.94 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 9.5153 | 174.19 | 1657.50 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 30.61 |
SMSTORE2_LIGHTS | SMSTORE2 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
SMSTORE3_LIGHTS | SMSTORE3 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
SMSTORE4_LIGHTS | SMSTORE4 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
LGSTORE2_LIGHTS | LGSTORE2 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 85.86 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 11.0315 | 4180.64 | 46118.53 | 704.17 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7048.38 | AstronomicalClock | - | 83.54 | 83.54 | 110.53 | |
Exterior Lighting Total | 7048.38 | 110.53 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 31032.14 | 24784.13 | 6248.01 | 0.80 | 3.50 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17275.45 | 13797.21 | 3478.24 | 0.80 | 3.91 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17281.15 | 13801.76 | 3479.39 | 0.80 | 3.91 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17335.72 | 13845.35 | 3490.37 | 0.80 | 3.91 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17186.63 | 13726.27 | 3460.36 | 0.80 | 3.91 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 30102.77 | 24041.88 | 6060.89 | 0.80 | 3.50 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15637.04 | 12488.68 | 3148.36 | 0.80 | 3.91 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15510.25 | 12387.42 | 3122.83 | 0.80 | 3.91 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15273.22 | 12198.11 | 3075.11 | 0.80 | 3.91 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 14950.69 | 11940.52 | 3010.17 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 29563.0 | 10.03 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 16457.6 | 30.76 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 16463.0 | 41.76 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 16515.0 | 52.63 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 16373.0 | 64.08 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 28677.6 | 43.37 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14896.7 | 102.61 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14775.9 | 114.46 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 14550.1 | 127.23 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 14242.9 | 140.98 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 54916.77 | 0.80 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29533.43 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29413.92 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29945.11 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29257.25 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 53646.77 | 0.80 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27555.17 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27368.10 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27000.32 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26326.54 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 1.87 | 2051.82 | 1094.51 | 1.00 | 1.29 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.04 | 1189.83 | 1140.11 | 1.00 | 1.35 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.04 | 1190.22 | 1140.11 | 1.00 | 1.35 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.05 | 1193.98 | 1140.11 | 1.00 | 1.35 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.04 | 1183.71 | 1140.11 | 1.00 | 1.35 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 1.82 | 1990.37 | 1094.51 | 1.00 | 1.30 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.94 | 1076.99 | 1140.11 | 1.00 | 1.38 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.94 | 1068.25 | 1140.11 | 1.00 | 1.38 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.92 | 1051.93 | 1140.11 | 1.00 | 1.38 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.90 | 1029.71 | 1140.11 | 1.00 | 1.39 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 21064.86 | 25277.83 | 72.56 | 1.562 | 1.875 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.89 | 0.00873 | 26.40 | 0.00838 | 0.411 | 0.00 |
SMSTORE1 | 11900.07 | 14280.08 | 81.98 | 0.858 | 1.029 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00885 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE2 | 11842.69 | 14211.23 | 81.58 | 0.853 | 1.024 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00898 | 21.39 | 0.00838 | 0.206 | 0.00 |
SMSTORE3 | 11767.67 | 14121.20 | 81.07 | 0.873 | 1.047 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 23.89 | 23.89 | 0.00870 | 26.25 | 0.00838 | 0.206 | 0.00 |
SMSTORE4 | 11764.54 | 14117.45 | 81.04 | 0.847 | 1.017 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00899 | 21.39 | 0.00838 | 0.206 | 0.00 |
LGSTORE2 | 20433.92 | 24520.71 | 70.38 | 1.515 | 1.819 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 23.89 | 23.89 | 0.00874 | 26.17 | 0.00838 | 0.411 | 0.00 |
SMSTORE5 | 10913.35 | 13096.02 | 75.18 | 0.785 | 0.942 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00898 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE6 | 10820.13 | 12984.16 | 74.54 | 0.778 | 0.933 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00899 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE7 | 10636.86 | 12764.23 | 73.28 | 0.764 | 0.917 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00903 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE8 | 10302.09 | 12362.51 | 70.97 | 0.739 | 0.887 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00905 | 22.94 | 0.00838 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 23767.35 | 28520.82 | 81.87 | 1.035 | 1.243 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00653 | -4.30 | 0.00266 | 0.411 | 0.00 |
SMSTORE1 | 12151.90 | 14582.27 | 83.71 | 0.529 | 0.635 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00640 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE2 | 12314.66 | 14777.59 | 84.83 | 0.537 | 0.644 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00642 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE3 | 12426.29 | 14911.55 | 85.60 | 0.541 | 0.650 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00643 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE4 | 12606.61 | 15127.93 | 86.85 | 0.549 | 0.659 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00644 | -4.30 | 0.00266 | 0.206 | 0.00 |
LGSTORE2 | 23710.78 | 28452.94 | 81.67 | 1.033 | 1.240 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00654 | -4.30 | 0.00266 | 0.411 | 0.00 |
SMSTORE5 | 12930.82 | 15516.98 | 89.08 | 0.563 | 0.676 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00646 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE6 | 12918.71 | 15502.45 | 89.00 | 0.563 | 0.675 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00646 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE7 | 13127.86 | 15753.44 | 90.44 | 0.572 | 0.686 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00648 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE8 | 14522.92 | 17427.50 | 100.05 | 0.633 | 0.759 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00656 | -4.30 | 0.00266 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 1.87 | 1.87 | 1.24 | 1.24 | 1.8747 | 1.8747 | 1.8747 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.04 | 1.04 | 0.64 | 0.64 | 1.0436 | 1.0291 | 1.0436 | 0.9860 | 1.0000 |
PSZ-AC_3:3 | 1.04 | 1.04 | 0.64 | 0.64 | 1.0440 | 1.0238 | 1.0440 | 0.9807 | 1.0000 |
PSZ-AC_4:4 | 1.05 | 1.05 | 0.65 | 0.65 | 1.0473 | 1.0473 | 1.0473 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.04 | 1.04 | 0.66 | 0.66 | 1.0382 | 1.0168 | 1.0382 | 0.9794 | 1.0000 |
PSZ-AC_6:6 | 1.82 | 1.82 | 1.24 | 1.24 | 1.8185 | 1.8185 | 1.8185 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 0.94 | 0.94 | 0.68 | 0.68 | 0.9446 | 0.9416 | 0.9446 | 0.9968 | 1.0000 |
PSZ-AC_8:8 | 0.94 | 0.94 | 0.68 | 0.68 | 0.9370 | 0.9333 | 0.9370 | 0.9961 | 1.0000 |
PSZ-AC_9:9 | 0.92 | 0.92 | 0.69 | 0.69 | 0.9227 | 0.9171 | 0.9227 | 0.9939 | 1.0000 |
PSZ-AC_10:10 | 0.90 | 0.90 | 0.76 | 0.76 | 0.9032 | 0.8873 | 0.9032 | 0.9824 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 31032.140 | 0.000 | 1.874650 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 31032.14 | 30137.26 | 1.874650 | 24.44 | 16.55 | 0.00865476 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 21.9483 | 23.89 | 0.00873088 | 46.7933 | 21064.86 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 54916.769 | 54916.769 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 54916.77 | 54916.77 | 1.874652 | 12.69 | 8.49 | 0.00524933 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 21.9483 | 21.10 | 0.00653239 | 41.6112 | 23767.35 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 17275.450 | 0.000 | 1.043610 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17275.45 | 16818.24 | 1.043610 | 24.38 | 16.52 | 0.00864109 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 19.7130 | 23.89 | 0.00885052 | 47.4280 | 11711.32 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 29533.433 | 29533.433 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29533.43 | 29533.43 | 1.043610 | 12.88 | 8.51 | 0.00519070 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 19.7130 | 21.10 | 0.00640385 | 40.8020 | 12151.90 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 17281.150 | 0.000 | 1.043950 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17281.15 | 16823.73 | 1.043950 | 24.38 | 16.52 | 0.00864111 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 19.7066 | 23.89 | 0.00898164 | 48.1222 | 11708.46 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 29413.917 | 29413.917 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29413.92 | 29413.92 | 1.043954 | 12.99 | 8.59 | 0.00521543 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 19.7065 | 21.10 | 0.00641662 | 40.8826 | 12314.66 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 17335.720 | 0.000 | 1.047250 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17335.72 | 16877.10 | 1.047250 | 24.37 | 16.51 | 0.00864085 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 19.6445 | 23.89 | 0.00870367 | 46.6493 | 11760.24 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 29945.112 | 29945.112 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29945.11 | 29945.11 | 1.047251 | 13.06 | 8.64 | 0.00523219 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 19.6445 | 21.10 | 0.00642536 | 40.9377 | 12426.29 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 17186.630 | 0.000 | 1.038240 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17186.63 | 16730.24 | 1.038240 | 24.37 | 16.51 | 0.00864144 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 19.8149 | 23.89 | 0.00898858 | 48.1589 | 11659.23 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 29257.255 | 29257.255 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29257.25 | 29257.25 | 1.038244 | 13.18 | 8.72 | 0.00525895 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 19.8149 | 21.10 | 0.00643945 | 41.0266 | 12606.61 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 30102.770 | 0.000 | 1.818510 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 30102.77 | 29219.63 | 1.818510 | 24.44 | 16.55 | 0.00865753 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 22.6259 | 23.89 | 0.00873791 | 46.8304 | 20416.92 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 53646.770 | 53646.770 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 53646.77 | 53646.77 | 1.818508 | 12.67 | 8.48 | 0.00525051 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.6259 | 21.10 | 0.00653873 | 41.6511 | 23710.78 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 15637.040 | 0.000 | 0.944630 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15637.04 | 15204.43 | 0.944630 | 24.42 | 16.54 | 0.00864811 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 21.7785 | 23.89 | 0.00897604 | 48.0929 | 10527.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 27555.175 | 27555.175 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27555.17 | 27555.17 | 0.944634 | 13.37 | 8.87 | 0.00530558 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 21.7785 | 21.10 | 0.00646393 | 41.1810 | 12930.82 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 15510.250 | 0.000 | 0.936970 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15510.25 | 15080.36 | 0.936970 | 24.45 | 16.55 | 0.00864864 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 21.9566 | 23.89 | 0.00899178 | 48.1763 | 10439.09 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 27368.097 | 27368.097 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27368.10 | 27368.10 | 0.936974 | 13.37 | 8.86 | 0.00530389 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 21.9565 | 21.10 | 0.00646305 | 41.1755 | 12918.71 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 15273.220 | 0.000 | 0.922660 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15273.22 | 14848.23 | 0.922660 | 24.45 | 16.55 | 0.00864932 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 22.2971 | 23.89 | 0.00903091 | 48.3835 | 10323.53 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 27000.319 | 27000.319 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27000.32 | 27000.32 | 0.922655 | 13.49 | 8.95 | 0.00533305 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.2972 | 21.10 | 0.00647833 | 41.2719 | 13127.86 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 14950.690 | 0.000 | 0.903170 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14950.69 | 14532.18 | 0.903170 | 24.41 | 16.54 | 0.00864976 | 12.80 | 12.00 | 0.00850000 | 26.17 | 0.00838408 | 16.92 | 22.7783 | 23.89 | 0.00904531 | 48.4595 | 10123.64 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 26326.535 | 26326.535 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26326.54 | 26326.54 | 0.903171 | 14.22 | 9.47 | 0.00550190 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.7783 | 21.10 | 0.00655904 | 41.7812 | 14522.92 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 31032.140 | 0.000 | 1.874650 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9288 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 31032.14 | 30137.26 | 1.0000 | 2.23340554 | 1.874650 | 24.44 | 16.55 | 0.00865476 | 46596.8 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31032.14 | 26.40 | 0.00838408 | 17.00 | 0.41145340 | 21.9483 | 23.89 | 0.00873088 | 23.89 | 0.00873088 | 46.7933 | 21064.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 54916.769 | 54916.769 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.874652 | 2.23340778 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 54916.77 | 54916.77 | 1.0000 | 2.23340778 | 1.874652 | 12.69 | 8.49 | 0.00524933 | 26007.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 54916.77 | -4.30 | 0.00265759 | -4.30 | 0.41145340 | 21.9483 | 21.11 | 0.00653239 | 21.10 | 0.00653239 | 41.6112 | 23767.35 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17275.450 | 0.000 | 1.043610 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9034 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17275.45 | 16818.24 | 1.0000 | 1.24332774 | 1.043610 | 24.38 | 16.52 | 0.00864109 | 46505.4 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17275.45 | 26.40 | 0.00838408 | 17.00 | 0.20572670 | 19.7130 | 23.89 | 0.00870430 | 23.89 | 0.00885052 | 47.4280 | 11711.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29533.433 | 29533.433 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.043610 | 1.24332789 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29533.43 | 29533.43 | 1.0000 | 1.24332789 | 1.043610 | 12.88 | 8.51 | 0.00519070 | 26047.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29533.43 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 19.7130 | 21.11 | 0.00640385 | 21.10 | 0.00640385 | 40.8020 | 12151.90 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17281.150 | 0.000 | 1.043950 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9034 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17281.15 | 16823.73 | 1.0000 | 1.24373281 | 1.043950 | 24.38 | 16.52 | 0.00864111 | 46505.6 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17281.15 | 26.40 | 0.00838408 | 17.00 | 0.20572670 | 19.7066 | 23.89 | 0.00870434 | 23.89 | 0.00898164 | 48.1222 | 11708.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29413.917 | 29413.917 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.043954 | 1.24373812 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29413.92 | 29413.92 | 1.0000 | 1.24373812 | 1.043954 | 12.99 | 8.59 | 0.00521543 | 26219.8 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29413.92 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 19.7065 | 21.11 | 0.00641662 | 21.10 | 0.00641662 | 40.8826 | 12314.66 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17335.720 | 0.000 | 1.047250 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9029 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17335.72 | 16877.10 | 1.0000 | 1.24766434 | 1.047250 | 24.37 | 16.51 | 0.00864085 | 46487.5 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17335.72 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 19.6445 | 23.89 | 0.00870367 | 23.89 | 0.00870367 | 46.6493 | 11760.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29945.112 | 29945.112 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.047251 | 1.24766506 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29945.11 | 29945.11 | 1.0000 | 1.24766506 | 1.047251 | 13.06 | 8.64 | 0.00523219 | 26336.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29945.11 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 19.6445 | 21.11 | 0.00642536 | 21.10 | 0.00642536 | 40.9377 | 12426.29 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17186.630 | 0.000 | 1.038240 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9040 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 17186.63 | 16730.24 | 1.0000 | 1.23693008 | 1.038240 | 24.37 | 16.51 | 0.00864144 | 46493.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17186.63 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 19.8149 | 23.89 | 0.00870508 | 23.89 | 0.00898858 | 48.1589 | 11659.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29257.255 | 29257.255 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.038244 | 1.23693538 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 29257.25 | 29257.25 | 1.0000 | 1.23693538 | 1.038244 | 13.18 | 8.72 | 0.00525895 | 26520.5 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29257.25 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 19.8149 | 21.11 | 0.00643945 | 21.10 | 0.00643945 | 41.0266 | 12606.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 30102.770 | 0.000 | 1.818510 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9339 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 30102.77 | 29219.63 | 1.0000 | 2.16652192 | 1.818510 | 24.44 | 16.55 | 0.00865753 | 46604.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30102.77 | 26.32 | 0.00838408 | 16.97 | 0.41145340 | 22.6259 | 23.89 | 0.00873758 | 23.89 | 0.00873791 | 46.8304 | 20416.92 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 53646.770 | 53646.770 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.818508 | 2.16652011 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 53646.77 | 53646.77 | 1.0000 | 2.16652011 | 1.818508 | 12.67 | 8.48 | 0.00525051 | 25989.8 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 53646.77 | -4.30 | 0.00265759 | -4.30 | 0.41145340 | 22.6259 | 21.11 | 0.00653873 | 21.10 | 0.00653873 | 41.6511 | 23710.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15637.040 | 0.000 | 0.944630 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9164 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15637.04 | 15204.43 | 1.0000 | 1.12540574 | 0.944630 | 24.42 | 16.54 | 0.00864811 | 46563.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15637.04 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 21.7785 | 23.89 | 0.00872240 | 23.89 | 0.00897604 | 48.0929 | 10527.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27555.175 | 27555.175 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.944634 | 1.12540997 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27555.17 | 27555.17 | 1.0000 | 1.12540997 | 0.944634 | 13.37 | 8.87 | 0.00530558 | 26840.0 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27555.17 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 21.7785 | 21.11 | 0.00646393 | 21.10 | 0.00646393 | 41.1810 | 12930.82 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15510.250 | 0.000 | 0.936970 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9174 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15510.25 | 15080.36 | 1.0000 | 1.11627983 | 0.936970 | 24.45 | 16.55 | 0.00864864 | 46587.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15510.25 | 26.40 | 0.00838408 | 17.00 | 0.20572670 | 21.9566 | 23.89 | 0.00872404 | 23.89 | 0.00899178 | 48.1763 | 10439.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27368.097 | 27368.097 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.936974 | 1.11628464 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27368.10 | 27368.10 | 1.0000 | 1.11628464 | 0.936974 | 13.37 | 8.86 | 0.00530389 | 26828.4 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27368.10 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 21.9565 | 21.11 | 0.00646305 | 21.10 | 0.00646305 | 41.1755 | 12918.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15273.220 | 0.000 | 0.922660 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9186 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15273.22 | 14848.23 | 1.0000 | 1.09923130 | 0.922660 | 24.45 | 16.55 | 0.00864932 | 46595.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15273.22 | 26.40 | 0.00838408 | 17.00 | 0.20572670 | 22.2971 | 23.89 | 0.00872599 | 23.89 | 0.00903091 | 48.3835 | 10323.53 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27000.319 | 27000.319 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.922655 | 1.09922571 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27000.32 | 27000.32 | 1.0000 | 1.09922571 | 0.922655 | 13.49 | 8.95 | 0.00533305 | 27027.2 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27000.32 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.2972 | 21.11 | 0.00647833 | 21.10 | 0.00647833 | 41.2719 | 13127.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14950.690 | 0.000 | 0.903170 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9195 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14950.69 | 14532.18 | 1.0000 | 1.07601146 | 0.903170 | 24.41 | 16.54 | 0.00864976 | 46553.8 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14950.69 | 26.17 | 0.00838408 | 16.92 | 0.20572670 | 22.7783 | 23.89 | 0.00872838 | 23.89 | 0.00904531 | 48.4595 | 10123.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26326.535 | 26326.535 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.903171 | 1.07601310 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26326.54 | 26326.54 | 1.0000 | 1.07601310 | 0.903171 | 14.22 | 9.47 | 0.00550190 | 28196.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26326.54 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.7783 | 21.11 | 0.00655904 | 21.10 | 0.00655904 | 41.7812 | 14522.92 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC_1:1_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.87 | - | |||
PSZ-AC_2:2_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.04 | - | |||
PSZ-AC_3:3_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.04 | - | |||
PSZ-AC_4:4_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.05 | - | |||
PSZ-AC_5:5_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.04 | - | |||
PSZ-AC_6:6_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.82 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 1488.50 | 3812.67 | 221.00 |
SMSTORE1 | 1515.33 | 3486.67 | 28.00 |
SMSTORE2 | 1191.17 | 2762.67 | 68.33 |
SMSTORE3 | 1193.50 | 2803.33 | 102.00 |
SMSTORE4 | 1156.50 | 2887.67 | 145.83 |
LGSTORE2 | 975.17 | 2833.83 | 261.83 |
SMSTORE5 | 856.17 | 2973.67 | 285.50 |
SMSTORE6 | 843.83 | 3035.50 | 311.50 |
SMSTORE7 | 873.50 | 3136.33 | 401.17 |
SMSTORE8 | 1215.33 | 3315.00 | 893.67 |
Facility | 2579.67 | 4642.17 | 1056.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 0.83 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 0.17 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 0.33 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 1.67 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 16.17 | 0.00 | 0.00 | 0.00 |
Facility | 17.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 1.077 | 0.366 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 1.067 | 0.406 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 1.203 | 0.531 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 1.195 | 0.531 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 1.168 | 0.531 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 1.074 | 0.497 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 0.831 | 0.566 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 0.831 | 0.565 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 0.831 | 0.565 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 0.830 | 0.586 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.807 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.807 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.807 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 0.808 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 0.808 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 0.808 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 0.808 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 0.808 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
Electricity:Building | 832.89 | 2755.34 | 01-JAN-00:10 | 51902.14 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 186.96 | 509.76 | 01-JAN-00:10 | 9610.45 | 01-JAN-10:10 |
InteriorLights:Electricity | 704.17 | 2305.93 | 01-JAN-00:10 | 43812.60 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 160.61 | 434.85 | 01-JAN-00:10 | 8262.19 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 704.17 | 2305.93 | 01-JAN-00:10 | 43812.60 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 102.73 | 279.91 | 01-JAN-00:10 | 5280.82 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 89.55 | 242.46 | 01-JAN-00:10 | 4606.69 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 105.13 | 394.07 | 01-JAN-00:10 | 7412.39 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 85.86 | 319.16 | 01-JAN-00:10 | 6064.13 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
Electricity:Plant | 65.19 | 1218.00 | 09-JAN-07:10 | 11858.20 | 21-NOV-13:40 |
WaterSystems:Electricity | 65.19 | 1218.00 | 09-JAN-07:10 | 11858.20 | 21-NOV-13:40 |
Water Heater:WaterSystems:Electricity | 65.19 | 1218.00 | 09-JAN-07:10 | 11858.20 | 21-NOV-13:40 |
ElectricityPurchased:Facility | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
ElectricityPurchased:Plant | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
Cogeneration:ElectricityPurchased | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
ElectricityNet:Plant | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
Cogeneration:ElectricityNet | 1250.92 | 3973.34 | 29-JAN-08:00 | 103313.61 | 22-JUL-15:40 |
Electricity:HVAC | 242.31 | 0.00 | 01-JAN-00:10 | 43956.93 | 22-JUL-15:00 |
Fans:Electricity | 224.93 | 0.00 | 01-JAN-00:10 | 13026.81 | 01-JAN-09:10 |
General:Fans:Electricity | 224.93 | 0.00 | 01-JAN-00:10 | 13026.81 | 01-JAN-09:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 17.38 | 0.00 | 01-JAN-00:10 | 30930.12 | 22-JUL-15:00 |
ExteriorLights:Electricity | 110.53 | 0.00 | 01-JAN-08:20 | 7048.38 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 110.53 | 0.00 | 01-JAN-08:20 | 7048.38 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 377.70 | 0.00 | 01-JAN-00:10 | 170020.52 | 10-JAN-08:10 |
Gas:HVAC | 377.70 | 0.00 | 01-JAN-00:10 | 170020.52 | 10-JAN-08:10 |
Heating:Gas | 377.70 | 0.00 | 01-JAN-00:10 | 170020.52 | 10-JAN-08:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 756.60 | 0.00 | 01-JAN-00:10 | 238417.30 | 10-JAN-08:10 |
EnergyTransfer:Building | 388.94 | 0.00 | 01-JAN-00:10 | 102400.88 | 10-JAN-08:10 |
EnergyTransfer:Zone:LGSTORE1 | 85.86 | 0.00 | 01-JAN-00:10 | 16611.19 | 10-JAN-08:10 |
Heating:EnergyTransfer | 114.33 | 0.00 | 01-JAN-00:10 | 101542.63 | 10-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 12.56 | 0.00 | 01-JAN-00:10 | 16611.19 | 10-JAN-08:10 |
Cooling:EnergyTransfer | 274.61 | 0.00 | 01-JAN-00:10 | 85494.66 | 22-JUL-15:00 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 73.30 | 0.00 | 01-JAN-00:10 | 14783.56 | 22-JUL-16:20 |
EnergyTransfer:Zone:SMSTORE1 | 44.10 | 0.00 | 01-JAN-00:10 | 10237.88 | 14-AUG-21:00 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 3.70 | 0.00 | 01-JAN-00:10 | 5597.82 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 40.40 | 0.00 | 01-JAN-00:10 | 10237.88 | 14-AUG-21:00 |
EnergyTransfer:Zone:SMSTORE2 | 33.20 | 0.00 | 01-JAN-00:10 | 7803.89 | 22-JUL-15:00 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 5.72 | 0.00 | 01-JAN-00:10 | 6657.67 | 10-JAN-07:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 27.49 | 0.00 | 01-JAN-00:10 | 7803.89 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE3 | 32.65 | 0.00 | 01-JAN-00:10 | 7765.72 | 22-JUL-15:00 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 6.66 | 0.00 | 01-JAN-00:10 | 7621.66 | 10-JAN-07:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 25.99 | 0.00 | 01-JAN-00:10 | 7765.72 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE4 | 31.42 | 0.00 | 01-JAN-00:10 | 8472.09 | 10-JAN-07:10 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 7.91 | 0.00 | 01-JAN-00:10 | 8472.09 | 10-JAN-07:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 23.51 | 0.00 | 01-JAN-00:10 | 7607.59 | 22-JUL-15:00 |
EnergyTransfer:Zone:LGSTORE2 | 51.25 | 0.00 | 01-JAN-00:10 | 20528.92 | 10-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 18.92 | 0.00 | 01-JAN-00:10 | 20528.92 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 32.33 | 0.00 | 01-JAN-00:10 | 13252.39 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE5 | 26.74 | 0.00 | 01-JAN-00:10 | 11085.36 | 31-DEC-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 11.45 | 0.00 | 01-JAN-00:10 | 10759.43 | 31-DEC-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 15.29 | 0.00 | 01-JAN-00:10 | 6900.68 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE6 | 26.40 | 0.00 | 01-JAN-00:10 | 11648.52 | 10-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 11.96 | 0.00 | 01-JAN-00:10 | 11115.57 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 14.44 | 0.00 | 01-JAN-00:10 | 6815.80 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE7 | 26.53 | 0.00 | 01-JAN-00:10 | 12506.98 | 26-DEC-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 13.85 | 0.00 | 01-JAN-00:10 | 12103.20 | 26-DEC-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 12.68 | 0.00 | 01-JAN-00:10 | 6659.02 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE8 | 30.76 | 0.00 | 01-JAN-00:10 | 16111.57 | 26-DEC-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 21.58 | 0.00 | 01-JAN-00:10 | 15959.69 | 26-DEC-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 9.18 | 0.00 | 01-JAN-00:10 | 6452.51 | 22-JUL-15:00 |
EnergyTransfer:HVAC | 367.67 | 0.00 | 01-JAN-00:10 | 136016.42 | 10-JAN-08:10 |
HeatingCoils:EnergyTransfer | 302.16 | 0.00 | 01-JAN-00:10 | 136016.42 | 10-JAN-08:10 |
CoolingCoils:EnergyTransfer | 65.51 | 0.00 | 01-JAN-00:10 | 113818.66 | 22-JUL-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 12.560 | -73.305 | 0.000 | 0.000 | 13.579 | 160.608 | 26.357 | 16.128 | 0.000 | 0.106 | 0.001 | 0.000 | -13.304 | 0.000 | -56.025 | -86.705 |
SMSTORE1 | 0.000 | 0.000 | 3.699 | -40.399 | 0.000 | 0.000 | 6.638 | 89.549 | 13.179 | 7.961 | 0.000 | 0.059 | 0.000 | 0.000 | -7.022 | 0.000 | -29.800 | -43.862 |
SMSTORE2 | 0.000 | 0.000 | 5.719 | -27.486 | 0.000 | 0.000 | 4.075 | 65.475 | 10.467 | 7.977 | 0.000 | 0.058 | 0.001 | 0.000 | -6.835 | 0.000 | -30.220 | -29.230 |
SMSTORE3 | 0.000 | 0.000 | 6.663 | -25.988 | 0.000 | 0.000 | 4.083 | 65.475 | 10.467 | 7.999 | 0.000 | 0.058 | 0.001 | 0.000 | -6.736 | 0.000 | -30.085 | -31.935 |
SMSTORE4 | 0.000 | 0.000 | 7.913 | -23.507 | 0.000 | 0.000 | 4.095 | 65.475 | 10.467 | 8.030 | 0.000 | 0.058 | 0.000 | 0.000 | -6.644 | 0.000 | -29.909 | -35.979 |
LGSTORE2 | 0.000 | 0.000 | 18.923 | -32.331 | 0.000 | 0.000 | 14.151 | 85.864 | 19.261 | 16.224 | 0.000 | 0.102 | 0.002 | 0.000 | -12.800 | 0.000 | -52.677 | -56.717 |
SMSTORE5 | 0.000 | 0.000 | 11.453 | -15.290 | 0.000 | 0.000 | 7.094 | 42.932 | 9.631 | 8.130 | 0.000 | 0.058 | 0.001 | 0.000 | -6.375 | 0.000 | -29.446 | -28.186 |
SMSTORE6 | 0.000 | 0.000 | 11.962 | -14.442 | 0.000 | 0.000 | 7.105 | 42.932 | 9.631 | 8.149 | 0.000 | 0.058 | 0.000 | 0.000 | -6.332 | 0.000 | -29.349 | -29.713 |
SMSTORE7 | 0.000 | 0.000 | 13.854 | -12.680 | 0.000 | 0.000 | 7.126 | 42.932 | 9.631 | 8.189 | 0.000 | 0.058 | 0.000 | 0.000 | -6.221 | 0.000 | -29.150 | -33.739 |
SMSTORE8 | 0.000 | 0.000 | 21.583 | -9.182 | 0.000 | 0.000 | 7.168 | 42.932 | 9.631 | 8.300 | 0.000 | 0.060 | 0.000 | 0.000 | -5.819 | 0.000 | -33.251 | -41.422 |
Total Facility | 0.000 | 0.000 | 114.329 | -274.608 | 0.000 | 0.000 | 75.113 | 704.173 | 128.721 | 97.086 | 0.000 | 0.675 | 0.007 | 0.000 | -78.087 | 0.000 | -349.912 | -417.489 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 23-JUL-07:03 | 0.00 | 0.00 | 0.00 | -23129.22 | 0.00 | 0.00 | 98.57 | 434.85 | 74.90 | 110.73 | 0.00 | 0.00 | 22872.92 | 0.00 | -0.00 | 0.00 | -462.75 | 0.00 |
SMSTORE1 | 04-SEP-17:10 | 0.00 | 0.00 | 0.00 | -19646.79 | 0.00 | 0.00 | 630.38 | 4606.69 | 674.13 | 76.97 | 0.00 | 0.00 | 13905.90 | 0.00 | -0.00 | 0.00 | -247.27 | 0.00 |
SMSTORE2 | 23-JUL-07:03 | 0.00 | 0.00 | 0.00 | -17158.50 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 43.90 | 0.00 | 0.00 | 17104.47 | 0.00 | -0.00 | 0.00 | -251.03 | 0.00 |
SMSTORE3 | 23-JUL-07:03 | 0.00 | 0.00 | 0.00 | -17230.01 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 43.40 | 0.00 | 0.00 | 17177.19 | 0.00 | -0.00 | 0.00 | -251.75 | 0.00 |
SMSTORE4 | 23-JUL-07:03 | 0.00 | 0.00 | 0.00 | -16963.60 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 45.80 | 0.00 | 0.00 | 16903.59 | 0.00 | -0.00 | 0.00 | -246.95 | 0.00 |
LGSTORE2 | 24-JUL-07:02 | 0.00 | 0.00 | 0.00 | -22944.59 | 0.00 | 0.00 | 0.00 | 319.16 | 74.90 | 71.66 | 0.00 | 0.00 | 23255.11 | 0.00 | -0.00 | 0.00 | -776.25 | 0.00 |
SMSTORE5 | 24-JUL-07:02 | 0.00 | 0.00 | 0.00 | -9997.31 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 36.76 | 0.00 | 0.00 | 10200.55 | 0.00 | -0.00 | 0.00 | -437.04 | 0.00 |
SMSTORE6 | 23-JUL-08:63 | 0.00 | 0.00 | 0.00 | -8913.14 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 233.95 | 0.00 | 0.00 | 8688.44 | 0.00 | -0.00 | 0.00 | -206.28 | 0.00 |
SMSTORE7 | 23-JUL-08:63 | 0.00 | 0.00 | 0.00 | -7009.56 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 237.79 | 0.00 | 0.00 | 6780.16 | 0.00 | -0.00 | 0.00 | -205.42 | 0.00 |
SMSTORE8 | 22-JUL-15:00 | 0.00 | 0.00 | 0.00 | -6452.65 | 0.00 | 0.00 | 840.49 | 3032.07 | 674.13 | 756.24 | 0.00 | 1379.84 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -230.11 |
Total Facility | 23-JUL-07:03 | 0.00 | 0.00 | 0.00 | -90768.31 | 0.00 | 0.00 | 146.40 | 2305.93 | 449.42 | 635.29 | 0.00 | 0.00 | 90805.40 | 0.00 | 0.00 | 0.00 | -3574.12 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 20-NOV-08:61 | 0.00 | 0.00 | 55224.10 | 0.00 | 0.00 | 0.00 | 131.90 | 434.85 | 74.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -736.60 | 0.00 | -1436.78 | -53692.38 |
SMSTORE1 | 17-FEB-08:61 | 0.00 | 0.00 | 29674.67 | 0.00 | 0.00 | 0.00 | 0.00 | 242.46 | 37.45 | 82.08 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -963.79 | -29072.87 |
SMSTORE2 | 10-JAN-07:01 | 0.00 | 0.00 | 29267.46 | 0.00 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -539.13 | 0.00 | -73.04 | -28916.46 |
SMSTORE3 | 26-DEC-07:01 | 0.00 | 0.00 | 29776.54 | 0.00 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -421.64 | 0.00 | -118.89 | -29497.17 |
SMSTORE4 | 26-DEC-07:01 | 0.00 | 0.00 | 29121.05 | 0.00 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -414.51 | 0.00 | -116.59 | -28851.11 |
LGSTORE2 | 20-NOV-08:61 | 0.00 | 0.00 | 53983.98 | 0.00 | 0.00 | 0.00 | 0.00 | 319.16 | 74.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -686.91 | 0.00 | -1338.10 | -52353.04 |
SMSTORE5 | 29-JAN-09:01 | 0.00 | 0.00 | 25599.95 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -146.22 | 0.00 | -413.76 | -25237.01 |
SMSTORE6 | 29-JAN-09:01 | 0.00 | 0.00 | 25439.55 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -144.19 | 0.00 | -409.61 | -25082.79 |
SMSTORE7 | 29-JAN-09:01 | 0.00 | 0.00 | 25158.92 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -137.26 | 0.00 | -394.91 | -24823.78 |
SMSTORE8 | 29-JAN-09:01 | 0.00 | 0.00 | 24776.04 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -114.52 | 0.00 | -404.55 | -24454.01 |
Total Facility | 26-DEC-08:61 | 0.00 | 0.00 | 240523.81 | 0.00 | 0.00 | 0.00 | 385.84 | 8346.03 | 1460.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -734.35 | 0.00 | -9936.22 | -240045.71 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8747 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8747 | 0.2195 | 1.0000 | 0.4115 | 0.2195 | ||
PSZ-AC_2:2 | 1.0291 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0436 | 0.1971 | 1.0000 | 0.2057 | 0.1971 | ||
PSZ-AC_3:3 | 1.0238 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0440 | 0.1971 | 1.0000 | 0.2057 | 0.1971 | ||
PSZ-AC_4:4 | 1.0473 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0473 | 0.1964 | 1.0000 | 0.2057 | 0.1964 | ||
PSZ-AC_5:5 | 1.0168 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0382 | 0.1981 | 1.0000 | 0.2057 | 0.1981 | ||
PSZ-AC_6:6 | 1.8185 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8185 | 0.2263 | 1.0000 | 0.4115 | 0.2263 | ||
PSZ-AC_7:7 | 0.9416 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9446 | 0.2178 | 1.0000 | 0.2057 | 0.2178 | ||
PSZ-AC_8:8 | 0.9333 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9370 | 0.2196 | 1.0000 | 0.2057 | 0.2196 | ||
PSZ-AC_9:9 | 0.9171 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9227 | 0.2230 | 1.0000 | 0.2057 | 0.2230 | ||
PSZ-AC_10:10 | 0.8873 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9032 | 0.2278 | 1.0000 | 0.2057 | 0.2278 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8747 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8747 | 1.0000 | 1.0000 | 0.4115 | 0.2195 | ||
PSZ-AC_2:2 | 1.0291 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0291 | 1.0000 | 1.0000 | 0.2057 | 0.1999 | ||
PSZ-AC_3:3 | 1.0238 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0238 | 1.0000 | 1.0000 | 0.2057 | 0.2010 | ||
PSZ-AC_4:4 | 1.0473 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0473 | 1.0000 | 1.0000 | 0.2057 | 0.1964 | ||
PSZ-AC_5:5 | 1.0168 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0168 | 1.0000 | 1.0000 | 0.2057 | 0.2023 | ||
PSZ-AC_6:6 | 1.8185 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8185 | 1.0000 | 1.0000 | 0.4115 | 0.2263 | ||
PSZ-AC_7:7 | 0.9416 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9416 | 1.0000 | 1.0000 | 0.2057 | 0.2185 | ||
PSZ-AC_8:8 | 0.9333 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9333 | 1.0000 | 1.0000 | 0.2057 | 0.2204 | ||
PSZ-AC_9:9 | 0.9171 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9171 | 1.0000 | 1.0000 | 0.2057 | 0.2243 | ||
PSZ-AC_10:10 | 0.8873 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8873 | 1.0000 | 1.0000 | 0.2057 | 0.2319 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8747 | 1.8747 | 1.8747 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.0291 | 1.0291 | 1.0291 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0238 | 1.0238 | 1.0238 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.0473 | 1.0473 | 1.0473 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0168 | 1.0168 | 1.0168 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.8185 | 1.8185 | 1.8185 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.9416 | 0.9416 | 0.9416 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.9333 | 0.9333 | 0.9333 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.9171 | 0.9171 | 0.9171 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.8873 | 0.8873 | 0.8873 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8747 | 1.8747 | 1.8747 | 1.8747 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0291 | 1.0436 | 1.0291 | 1.0291 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0238 | 1.0440 | 1.0238 | 1.0238 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0473 | 1.0473 | 1.0473 | 1.0473 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0168 | 1.0382 | 1.0168 | 1.0168 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.8185 | 1.8185 | 1.8185 | 1.8185 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.9416 | 0.9446 | 0.9416 | 0.9416 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.9333 | 0.9370 | 0.9333 | 0.9333 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.9171 | 0.9227 | 0.9171 | 0.9171 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.8873 | 0.9032 | 0.8873 | 0.8873 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8747 | 1.8747 | 1.8747 | 0.4115 | 0.3311 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.0291 | 1.0291 | 1.0291 | 0.2057 | 0.3238 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0238 | 1.0238 | 1.0238 | 0.2057 | 0.3195 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.0473 | 1.0473 | 1.0473 | 0.2057 | 0.3167 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0168 | 1.0168 | 1.0168 | 0.2057 | 0.3121 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.8185 | 1.8185 | 1.8185 | 0.4115 | 0.3319 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.9416 | 0.9416 | 0.9416 | 0.2057 | 0.3043 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.9333 | 0.9333 | 0.9333 | 0.2057 | 0.3046 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.9171 | 0.9171 | 0.9171 | 0.2057 | 0.2998 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.8873 | 0.8873 | 0.8873 | 0.2057 | 0.2710 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8747 | 1.8747 | 1.8747 | 1.8747 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0291 | 1.0291 | 1.0291 | 1.0291 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0238 | 1.0238 | 1.0238 | 1.0238 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0473 | 1.0473 | 1.0473 | 1.0473 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0168 | 1.0168 | 1.0168 | 1.0168 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.8185 | 1.8185 | 1.8185 | 1.8185 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.9416 | 0.9416 | 0.9416 | 0.9416 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.9333 | 0.9333 | 0.9333 | 0.9333 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.9171 | 0.9171 | 0.9171 | 0.9171 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.8873 | 0.8873 | 0.8873 | 0.8873 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:11
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885 |
Total gross floor area [m2] | 2090.32 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 377.70 | 170020.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 17.38 | 30930.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 704.17 | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 110.53 | 7048.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.72 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 224.93 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 65.19 | 11858.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.72 | 1250.92 |
Natural Gas | 0.00 | 377.70 |
Additional | 0.00 | 0.00 |
Total | 128.72 | 1628.62 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 336.87 |
Space Heating | 0.00 |
Space Cooling | 8.31 |
Fans (All) | 107.61 |
Service Water Heating | 31.19 |
Receptacle Equipment | 61.58 |
Miscellaneous (All) | 598.44 |
Subtotal | 598.44 |
Natural Gas [MJ/m2] | |
Space Heating | 180.69 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 180.69 |
Subtotal | 180.69 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 43.24 |
Space Heating | 23.19 |
Space Cooling | 1.07 |
Fans (All) | 13.81 |
Service Water Heating | 4.00 |
Receptacle Equipment | 7.90 |
Miscellaneous | 6.79 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5131. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4888. | 8760. |
TYPE2_EQUIP_SCH | 3911. | 8760. |
TYPE3_EQUIP_SCH | 3600. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.809580E+11 |
February | 0.000 | 0.657345E+11 |
March | 0.000 | 0.571416E+11 |
April | 0.000 | 0.125118E+11 |
May | 0.000 | 0.853991E+10 |
June | 0.000 | 0.586689E+09 |
July | 0.000 | 0.980089E+08 |
August | 0.000 | 0.000 |
September | 0.000 | 0.179841E+09 |
October | 0.000 | 0.139799E+11 |
November | 0.000 | 0.495758E+11 |
December | 0.000 | 0.883929E+11 |
Annual Sum or Average | 0.377699E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.883929E+11 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.280695E+10 | 7728.43 | 13-JAN-00:12 | 0.13 | -0.7 | 0.568785E+09 | 693.61 | 29-JAN-18:00 | 9.00 | 8.43 |
February | 0.252788E+10 | 8423.62 | 17-FEB-00:12 | -1.3 | -1.3 | 0.513046E+09 | 680.12 | 20-FEB-17:30 | 7.50 | 4.72 |
March | 0.325023E+10 | 7157.58 | 03-MAR-00:13 | 1.50 | 0.90 | 0.565771E+09 | 742.22 | 19-MAR-17:00 | 11.00 | 10.48 |
April | 0.653922E+10 | 11270.29 | 30-APR-16:05 | 24.00 | 13.01 | 0.625394E+09 | 899.06 | 30-APR-12:09 | 22.00 | 13.84 |
May | 0.670945E+10 | 9065.58 | 22-MAY-15:00 | 24.00 | 16.06 | 0.659572E+09 | 899.03 | 21-MAY-17:10 | 20.00 | 12.84 |
June | 0.844537E+10 | 13080.72 | 13-JUN-17:00 | 27.00 | 17.51 | 0.710229E+09 | 899.10 | 25-JUN-17:00 | 22.00 | 19.93 |
July | 0.107237E+11 | 23131.69 | 23-JUL-07:03 | 18.17 | 14.52 | 0.750890E+09 | 899.04 | 16-JUL-16:40 | 18.67 | 15.21 |
August | 0.111437E+11 | 18294.22 | 06-AUG-07:02 | 13.17 | 12.51 | 0.742894E+09 | 899.05 | 20-AUG-17:10 | 21.17 | 14.67 |
September | 0.925509E+10 | 17847.79 | 16-SEP-07:02 | 14.33 | 14.14 | 0.724664E+09 | 899.03 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.594006E+10 | 7094.24 | 01-OCT-17:20 | 11.67 | 8.73 | 0.645500E+09 | 898.99 | 01-OCT-17:19 | 11.67 | 8.73 |
November | 0.365427E+10 | 6165.72 | 04-NOV-24:00 | 3.00 | 3.00 | 0.554107E+09 | 730.86 | 10-NOV-13:00 | 12.00 | 8.90 |
December | 0.230881E+10 | 9008.70 | 30-DEC-00:12 | -2.7 | -4.1 | 0.571135E+09 | 680.12 | 15-DEC-13:09 | 6.00 | 5.05 |
Annual Sum or Average | 0.733048E+11 | 0.763199E+10 | ||||||||
Minimum of Months | 0.230881E+10 | 6165.72 | -2.7 | -4.1 | 0.513046E+09 | 680.12 | 6.00 | 4.72 | ||
Maximum of Months | 0.111437E+11 | 23131.69 | 27.00 | 17.51 | 0.750890E+09 | 899.10 | 22.00 | 19.93 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.121419E+10 | 3340.79 | 19-JAN-20:20 | 3.00 | 2.16 | 0.301392E+09 | 419.43 | 29-JAN-18:00 | 9.00 | 8.43 |
February | 0.108810E+10 | 3195.56 | 13-FEB-20:40 | 3.33 | 2.60 | 0.271077E+09 | 412.66 | 05-FEB-18:00 | 6.00 | 5.04 |
March | 0.146658E+10 | 3261.66 | 10-MAR-21:00 | 3.00 | 3.00 | 0.301633E+09 | 449.49 | 19-MAR-17:49 | 11.17 | 10.55 |
April | 0.335389E+10 | 19640.35 | 29-APR-18:59 | 18.00 | 11.44 | 0.334149E+09 | 449.53 | 30-APR-12:09 | 22.00 | 13.84 |
May | 0.359350E+10 | 18353.81 | 21-MAY-17:11 | 20.00 | 12.91 | 0.349041E+09 | 449.52 | 21-MAY-17:10 | 20.00 | 12.84 |
June | 0.519255E+10 | 18841.86 | 06-JUN-21:12 | 8.00 | 6.68 | 0.359007E+09 | 449.51 | 25-JUN-17:10 | 21.17 | 15.02 |
July | 0.650364E+10 | 19164.96 | 30-JUL-21:00 | 13.00 | 8.86 | 0.376150E+09 | 449.52 | 16-JUL-16:40 | 18.67 | 15.21 |
August | 0.681452E+10 | 19202.92 | 14-AUG-20:46 | 18.62 | 11.96 | 0.371180E+09 | 449.52 | 20-AUG-17:10 | 21.17 | 14.67 |
September | 0.567462E+10 | 19647.10 | 04-SEP-17:10 | 17.50 | 11.44 | 0.363455E+09 | 449.53 | 24-SEP-16:10 | 21.83 | 15.33 |
October | 0.302167E+10 | 19002.92 | 04-OCT-20:01 | 6.17 | 5.65 | 0.343219E+09 | 449.50 | 01-OCT-12:09 | 13.67 | 9.84 |
November | 0.158167E+10 | 3227.49 | 03-NOV-18:00 | 3.00 | 2.16 | 0.297224E+09 | 441.11 | 05-NOV-17:00 | 6.00 | 5.05 |
December | 0.893955E+09 | 3034.11 | 21-DEC-20:30 | 3.00 | 3.00 | 0.300550E+09 | 410.52 | 24-DEC-18:00 | 6.00 | 5.04 |
Annual Sum or Average | 0.403989E+11 | 0.396808E+10 | ||||||||
Minimum of Months | 0.893955E+09 | 3034.11 | 3.00 | 2.16 | 0.271077E+09 | 410.52 | 6.00 | 5.04 | ||
Maximum of Months | 0.681452E+10 | 19647.10 | 20.00 | 12.91 | 0.376150E+09 | 449.53 | 22.00 | 15.33 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.797298E+09 | 3424.64 | 20-JAN-08:61 | 2.00 | 1.57 | 0.169418E+09 | 340.06 | 28-JAN-13:30 | 10.50 | 8.92 |
February | 0.736786E+09 | 3340.56 | 09-FEB-08:61 | 2.33 | 2.26 | 0.153718E+09 | 340.06 | 04-FEB-13:09 | 9.00 | 6.12 |
March | 0.107297E+10 | 3612.46 | 21-MAR-07:01 | 1.33 | 0.85 | 0.174820E+09 | 374.17 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.237499E+10 | 5918.23 | 30-APR-15:00 | 24.00 | 13.10 | 0.190953E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.257618E+10 | 4852.32 | 22-MAY-15:00 | 24.00 | 16.06 | 0.201661E+09 | 449.49 | 27-MAY-12:50 | 15.17 | 10.66 |
June | 0.338297E+10 | 12468.67 | 27-JUN-06:02 | 15.00 | 15.00 | 0.219367E+09 | 449.49 | 24-JUN-12:09 | 16.83 | 12.75 |
July | 0.426452E+10 | 17158.12 | 23-JUL-07:03 | 18.17 | 14.52 | 0.223101E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.469634E+10 | 14921.41 | 19-AUG-06:01 | 12.00 | 11.46 | 0.229854E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.371553E+10 | 14903.50 | 02-SEP-06:02 | 13.17 | 12.51 | 0.217825E+09 | 449.52 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.211629E+10 | 3848.48 | 04-OCT-17:10 | 12.50 | 9.08 | 0.193740E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.115989E+10 | 3607.18 | 04-NOV-07:01 | 1.33 | 0.86 | 0.165124E+09 | 344.50 | 25-NOV-13:39 | 10.00 | 5.63 |
December | 0.591832E+09 | 3179.83 | 21-DEC-08:61 | 3.00 | 2.16 | 0.168962E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.274856E+11 | 0.230854E+10 | ||||||||
Minimum of Months | 0.591832E+09 | 3179.83 | 1.33 | 0.85 | 0.153718E+09 | 340.06 | 9.00 | 5.63 | ||
Maximum of Months | 0.469634E+10 | 17158.12 | 24.00 | 16.06 | 0.229854E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.665880E+09 | 3171.56 | 13-JAN-09:53 | 2.00 | 1.63 | 0.169293E+09 | 340.06 | 28-JAN-13:50 | 10.83 | 9.24 |
February | 0.638272E+09 | 2881.10 | 10-FEB-08:61 | 4.33 | 4.19 | 0.153677E+09 | 340.06 | 04-FEB-13:09 | 9.00 | 6.12 |
March | 0.936781E+09 | 3521.24 | 21-MAR-07:01 | 1.33 | 0.85 | 0.174517E+09 | 369.45 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.221086E+10 | 5816.47 | 30-APR-15:00 | 24.00 | 13.10 | 0.188775E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.243389E+10 | 4664.47 | 23-MAY-17:10 | 18.00 | 13.64 | 0.199430E+09 | 449.49 | 27-MAY-12:50 | 15.17 | 10.66 |
June | 0.326735E+10 | 11725.48 | 27-JUN-06:02 | 15.00 | 15.00 | 0.218841E+09 | 449.49 | 24-JUN-12:09 | 16.83 | 12.75 |
July | 0.417182E+10 | 17229.62 | 23-JUL-07:03 | 18.17 | 14.52 | 0.222947E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.461620E+10 | 13853.67 | 19-AUG-06:01 | 12.00 | 11.46 | 0.229839E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.360903E+10 | 13518.01 | 02-SEP-06:02 | 13.17 | 12.51 | 0.217689E+09 | 449.51 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.193148E+10 | 3869.66 | 04-OCT-17:10 | 12.50 | 9.08 | 0.191607E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.100419E+10 | 3559.07 | 04-NOV-07:01 | 1.33 | 0.86 | 0.164648E+09 | 340.06 | 18-NOV-13:09 | 10.00 | 7.78 |
December | 0.502453E+09 | 3167.78 | 29-DEC-10:43 | 2.00 | -0.1 | 0.168948E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.259882E+11 | 0.230021E+10 | ||||||||
Minimum of Months | 0.502453E+09 | 2881.10 | 1.33 | -0.1 | 0.153677E+09 | 340.06 | 9.00 | 6.12 | ||
Maximum of Months | 0.461620E+10 | 17229.62 | 24.00 | 15.00 | 0.229839E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.518474E+09 | 3365.01 | 09-JAN-11:33 | 1.13 | -0.6 | 0.169203E+09 | 340.06 | 28-JAN-13:00 | 11.00 | 9.40 |
February | 0.513917E+09 | 2813.89 | 18-FEB-09:33 | 3.67 | 2.78 | 0.153648E+09 | 340.06 | 04-FEB-13:09 | 9.00 | 6.12 |
March | 0.768998E+09 | 3186.31 | 15-MAR-09:13 | 2.00 | 1.57 | 0.174206E+09 | 362.87 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.197916E+10 | 5591.82 | 30-APR-15:00 | 24.00 | 13.10 | 0.185800E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.220303E+10 | 4399.40 | 23-MAY-17:10 | 18.00 | 13.64 | 0.196344E+09 | 449.49 | 27-MAY-12:50 | 15.17 | 10.66 |
June | 0.300215E+10 | 9277.60 | 27-JUN-06:02 | 15.00 | 15.00 | 0.217403E+09 | 449.49 | 24-JUN-12:09 | 16.83 | 12.75 |
July | 0.390868E+10 | 16963.23 | 23-JUL-07:03 | 18.17 | 14.52 | 0.222559E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.435465E+10 | 10405.13 | 19-AUG-06:01 | 12.00 | 11.46 | 0.229787E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.335501E+10 | 10523.65 | 02-SEP-06:02 | 13.17 | 12.51 | 0.217253E+09 | 449.51 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.169440E+10 | 3367.19 | 03-OCT-17:20 | 12.00 | 8.34 | 0.188675E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.827516E+09 | 3114.32 | 16-NOV-08:61 | 3.17 | 2.71 | 0.164207E+09 | 340.06 | 18-NOV-13:20 | 10.00 | 7.63 |
December | 0.380974E+09 | 2619.00 | 31-DEC-10:55 | 4.00 | 2.70 | 0.168940E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.235070E+11 | 0.228802E+10 | ||||||||
Minimum of Months | 0.380974E+09 | 2619.00 | 1.13 | -0.6 | 0.153648E+09 | 340.06 | 9.00 | 6.12 | ||
Maximum of Months | 0.435465E+10 | 16963.23 | 24.00 | 15.00 | 0.229787E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.361378E+09 | 6420.49 | 04-JAN-19:03 | 2.83 | 2.06 | 0.578273E+09 | 906.82 | 07-JAN-15:00 | 6.00 | 4.13 |
February | 0.370827E+09 | 4866.67 | 05-FEB-11:50 | 5.83 | 4.51 | 0.526483E+09 | 906.82 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.674767E+09 | 3703.02 | 23-MAR-17:10 | 9.67 | 6.56 | 0.596474E+09 | 907.01 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.281630E+10 | 9375.86 | 30-APR-15:00 | 24.00 | 13.10 | 0.615234E+09 | 1198.65 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.319977E+10 | 6500.95 | 22-MAY-15:00 | 24.00 | 16.06 | 0.648338E+09 | 1188.78 | 27-MAY-14:09 | 15.67 | 10.93 |
June | 0.451297E+10 | 10831.02 | 13-JUN-17:00 | 27.00 | 17.51 | 0.725132E+09 | 1198.66 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.580826E+10 | 22947.65 | 24-JUL-07:02 | 14.00 | 13.43 | 0.756725E+09 | 1198.65 | 29-JUL-14:09 | 17.00 | 13.95 |
August | 0.646194E+10 | 10701.32 | 14-AUG-17:00 | 27.00 | 14.36 | 0.788359E+09 | 1198.71 | 19-AUG-14:30 | 19.50 | 14.95 |
September | 0.485230E+10 | 9751.13 | 13-SEP-14:10 | 23.00 | 16.21 | 0.738755E+09 | 1198.68 | 23-SEP-14:30 | 19.00 | 14.77 |
October | 0.233184E+10 | 6128.01 | 05-OCT-20:00 | 5.00 | 4.08 | 0.621088E+09 | 1198.65 | 07-OCT-14:09 | 17.33 | 9.91 |
November | 0.742019E+09 | 3693.42 | 25-NOV-11:40 | 9.67 | 5.70 | 0.557223E+09 | 906.82 | 04-NOV-14:09 | 9.00 | 6.58 |
December | 0.198452E+09 | 6116.26 | 13-DEC-20:43 | 3.50 | 2.78 | 0.579252E+09 | 906.82 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.323308E+11 | 0.773134E+10 | ||||||||
Minimum of Months | 0.198452E+09 | 3693.42 | 2.83 | 2.06 | 0.526483E+09 | 906.82 | 5.00 | 4.13 | ||
Maximum of Months | 0.646194E+10 | 22947.65 | 27.00 | 17.51 | 0.788359E+09 | 1198.71 | 20.00 | 14.95 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.171447E+09 | 4804.32 | 12-JAN-08:04 | -1.8 | -3.6 | 0.289134E+09 | 453.41 | 07-JAN-15:00 | 6.00 | 4.13 |
February | 0.173551E+09 | 4936.71 | 17-FEB-08:04 | -2.3 | -2.4 | 0.263240E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.315209E+09 | 4072.50 | 21-MAR-07:03 | 1.33 | 0.85 | 0.298218E+09 | 453.42 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.123799E+10 | 4716.38 | 30-APR-15:00 | 24.00 | 13.10 | 0.305489E+09 | 599.32 | 22-APR-14:09 | 17.75 | 9.95 |
May | 0.142127E+10 | 3193.57 | 22-MAY-15:00 | 24.00 | 16.06 | 0.320939E+09 | 582.44 | 27-MAY-14:09 | 15.67 | 10.93 |
June | 0.215437E+10 | 5542.40 | 13-JUN-17:00 | 27.00 | 17.51 | 0.357622E+09 | 599.35 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.282545E+10 | 9998.34 | 24-JUL-07:02 | 14.00 | 13.43 | 0.376211E+09 | 599.34 | 15-JUL-14:20 | 18.00 | 12.88 |
August | 0.316776E+10 | 5521.29 | 14-AUG-17:00 | 27.00 | 14.36 | 0.393788E+09 | 599.34 | 05-AUG-14:00 | 20.00 | 14.16 |
September | 0.234574E+10 | 4886.56 | 13-SEP-14:20 | 23.00 | 16.21 | 0.366657E+09 | 599.35 | 09-SEP-14:20 | 20.00 | 14.18 |
October | 0.103558E+10 | 3457.04 | 23-OCT-07:03 | 4.50 | 4.42 | 0.307724E+09 | 599.33 | 07-OCT-14:09 | 17.33 | 9.91 |
November | 0.342705E+09 | 4497.33 | 29-NOV-08:04 | -0.7 | -1.5 | 0.278599E+09 | 453.41 | 04-NOV-14:20 | 9.00 | 6.58 |
December | 98683256.65 | 4602.81 | 27-DEC-08:04 | -1.0 | -1.3 | 0.289621E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.152898E+11 | 0.384724E+10 | ||||||||
Minimum of Months | 98683256.65 | 3193.57 | -2.3 | -3.6 | 0.263240E+09 | 453.41 | 5.00 | 4.13 | ||
Maximum of Months | 0.316776E+10 | 9998.34 | 27.00 | 17.51 | 0.393788E+09 | 599.35 | 20.00 | 14.18 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.154232E+09 | 5329.49 | 10-JAN-08:05 | -5.7 | -6.7 | 0.289136E+09 | 453.41 | 07-JAN-15:00 | 6.00 | 4.13 |
February | 0.150418E+09 | 4542.14 | 17-FEB-20:53 | -3.0 | -3.0 | 0.263244E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.286999E+09 | 4137.45 | 21-MAR-07:03 | 1.33 | 0.85 | 0.298213E+09 | 453.41 | 04-MAR-15:09 | 6.00 | 4.33 |
April | 0.115618E+10 | 4569.13 | 30-APR-15:00 | 24.00 | 13.10 | 0.304310E+09 | 599.32 | 22-APR-14:09 | 17.75 | 9.95 |
May | 0.132867E+10 | 3040.80 | 22-MAY-15:00 | 24.00 | 16.06 | 0.319153E+09 | 573.98 | 27-MAY-14:09 | 15.67 | 10.93 |
June | 0.203621E+10 | 5406.03 | 13-JUN-17:00 | 27.00 | 17.51 | 0.354458E+09 | 599.34 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.269306E+10 | 8912.86 | 23-JUL-08:63 | 19.17 | 15.33 | 0.374834E+09 | 599.34 | 15-JUL-14:20 | 18.00 | 12.88 |
August | 0.303558E+10 | 5411.81 | 14-AUG-17:00 | 27.00 | 14.36 | 0.393667E+09 | 599.34 | 05-AUG-14:00 | 20.00 | 14.16 |
September | 0.222912E+10 | 4770.87 | 13-SEP-14:20 | 23.00 | 16.21 | 0.364825E+09 | 599.35 | 09-SEP-14:20 | 20.00 | 14.18 |
October | 0.970212E+09 | 3440.37 | 23-OCT-07:03 | 4.50 | 4.42 | 0.305886E+09 | 599.33 | 07-OCT-14:09 | 17.33 | 9.91 |
November | 0.318290E+09 | 4566.53 | 29-NOV-08:04 | -0.7 | -1.5 | 0.278583E+09 | 453.41 | 04-NOV-14:20 | 9.00 | 6.58 |
December | 82722577.39 | 4144.05 | 31-DEC-09:05 | 0.33 | -0.2 | 0.289623E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.144417E+11 | 0.383593E+10 | ||||||||
Minimum of Months | 82722577.39 | 3040.80 | -5.7 | -6.7 | 0.263244E+09 | 453.41 | 5.00 | 4.13 | ||
Maximum of Months | 0.303558E+10 | 8912.86 | 27.00 | 17.51 | 0.393667E+09 | 599.35 | 20.00 | 14.18 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.112689E+09 | 5250.27 | 11-JAN-08:05 | -4.0 | -4.8 | 0.289130E+09 | 453.41 | 07-JAN-15:00 | 6.00 | 4.13 |
February | 93033796.37 | 4349.42 | 18-FEB-08:04 | 0.17 | -0.3 | 0.263243E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.208773E+09 | 4142.34 | 21-MAR-07:03 | 1.33 | 0.85 | 0.298181E+09 | 453.41 | 04-MAR-15:09 | 6.00 | 4.33 |
April | 0.984090E+09 | 4280.43 | 30-APR-15:00 | 24.00 | 13.10 | 0.302265E+09 | 599.32 | 22-APR-14:39 | 17.90 | 9.78 |
May | 0.113306E+10 | 2911.41 | 06-MAY-07:03 | 6.33 | 4.40 | 0.316214E+09 | 558.17 | 27-MAY-14:09 | 15.67 | 10.93 |
June | 0.182768E+10 | 5154.19 | 13-JUN-17:00 | 27.00 | 17.51 | 0.348511E+09 | 599.34 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.242945E+10 | 7009.31 | 23-JUL-08:63 | 19.17 | 15.33 | 0.372231E+09 | 599.34 | 15-JUL-14:20 | 18.00 | 12.88 |
August | 0.274270E+10 | 5181.58 | 14-AUG-17:00 | 27.00 | 14.36 | 0.393281E+09 | 599.33 | 26-AUG-14:09 | 17.83 | 14.80 |
September | 0.202112E+10 | 4562.47 | 13-SEP-14:20 | 23.00 | 16.21 | 0.361005E+09 | 599.35 | 09-SEP-14:30 | 20.00 | 14.18 |
October | 0.841841E+09 | 3386.01 | 12-OCT-07:04 | 3.67 | 3.67 | 0.302945E+09 | 599.32 | 07-OCT-14:39 | 18.33 | 10.03 |
November | 0.238002E+09 | 4162.98 | 04-NOV-07:03 | 1.33 | 0.86 | 0.278534E+09 | 453.41 | 04-NOV-14:20 | 9.00 | 6.58 |
December | 47629564.64 | 4206.26 | 08-DEC-08:04 | 1.00 | 0.66 | 0.289624E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.126801E+11 | 0.381516E+10 | ||||||||
Minimum of Months | 47629564.64 | 2911.41 | -4.0 | -4.8 | 0.263243E+09 | 453.41 | 5.00 | 4.13 | ||
Maximum of Months | 0.274270E+10 | 7009.31 | 27.00 | 17.51 | 0.393281E+09 | 599.35 | 20.00 | 14.80 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 19504665.26 | 4029.61 | 02-JAN-08:06 | 1.00 | 0.59 | 0.289135E+09 | 453.41 | 14-JAN-15:09 | 7.00 | 5.48 |
February | 14658346.91 | 4058.75 | 25-FEB-08:05 | 1.17 | 1.17 | 0.263242E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 37097552.35 | 3837.29 | 15-MAR-07:05 | 2.00 | 1.57 | 0.298194E+09 | 453.41 | 04-MAR-15:09 | 6.00 | 4.33 |
April | 0.642972E+09 | 3736.41 | 30-APR-15:00 | 24.00 | 13.10 | 0.299173E+09 | 599.32 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.678230E+09 | 2995.66 | 06-MAY-07:04 | 6.33 | 4.40 | 0.310891E+09 | 532.14 | 31-MAY-16:10 | 20.67 | 14.98 |
June | 0.143461E+10 | 4700.85 | 13-JUN-17:00 | 27.00 | 17.51 | 0.335963E+09 | 599.34 | 24-JUN-14:30 | 18.50 | 13.32 |
July | 0.192984E+10 | 6452.51 | 22-JUL-15:00 | 29.00 | 16.98 | 0.366233E+09 | 599.34 | 15-JUL-14:09 | 18.00 | 12.88 |
August | 0.213996E+10 | 4714.28 | 14-AUG-17:00 | 27.00 | 14.36 | 0.391372E+09 | 599.33 | 26-AUG-14:50 | 17.17 | 14.12 |
September | 0.164633E+10 | 4183.61 | 13-SEP-14:10 | 23.00 | 16.21 | 0.352596E+09 | 599.32 | 09-SEP-14:00 | 20.00 | 14.18 |
October | 0.552486E+09 | 3654.56 | 06-OCT-07:05 | 3.83 | 3.69 | 0.298335E+09 | 599.24 | 07-OCT-14:00 | 19.00 | 10.08 |
November | 77346268.39 | 3990.46 | 28-NOV-08:06 | 1.17 | -0.1 | 0.278503E+09 | 453.41 | 04-NOV-14:20 | 9.00 | 6.58 |
December | 8878647.27 | 3633.75 | 21-DEC-08:05 | 3.00 | 2.16 | 0.289625E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.918191E+10 | 0.377326E+10 | ||||||||
Minimum of Months | 8878647.27 | 2995.66 | 1.00 | -0.1 | 0.263242E+09 | 453.41 | 5.00 | 4.33 | ||
Maximum of Months | 0.213996E+10 | 6452.51 | 29.00 | 17.51 | 0.391372E+09 | 599.34 | 20.67 | 14.98 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.283396E+10 | 55214.58 | 31-JAN-08:61 | 1.17 |
February | 0.204846E+10 | 55218.05 | 17-FEB-08:61 | -2.3 |
March | 0.173112E+10 | 55212.88 | 03-MAR-08:61 | 3.17 |
April | 0.292213E+09 | 55143.86 | 11-APR-07:01 | 7.00 |
May | 0.223635E+09 | 55130.11 | 05-MAY-07:01 | 7.17 |
June | 0.115100E+09 | 2445.69 | 13-JUN-07:07 | 19.33 |
July | 67917785.43 | 2855.68 | 23-JUL-07:05 | 18.17 |
August | 39523368.26 | 2542.25 | 06-AUG-07:03 | 13.17 |
September | 0.124973E+09 | 2535.11 | 16-SEP-07:03 | 14.33 |
October | 0.246538E+09 | 54157.53 | 23-OCT-07:01 | 4.50 |
November | 0.130535E+10 | 55224.03 | 20-NOV-08:61 | 1.33 |
December | 0.353138E+10 | 55191.94 | 15-DEC-08:61 | 1.33 |
Annual Sum or Average | 0.125602E+11 | |||
Minimum of Months | 39523368.26 | 2445.69 | -2.3 | |
Maximum of Months | 0.353138E+10 | 55224.03 | 19.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.929373E+09 | 29670.65 | 10-JAN-08:61 | -5.7 |
February | 0.497448E+09 | 29674.75 | 17-FEB-08:61 | -2.3 |
March | 0.391994E+09 | 25132.53 | 04-MAR-08:61 | 4.00 |
April | 0.108538E+09 | 2329.18 | 10-APR-13:00 | 7.00 |
May | 95824346.86 | 1169.55 | 01-MAY-07:25 | 7.50 |
June | 29031394.70 | 1645.05 | 27-JUN-07:04 | 15.00 |
July | 19684961.17 | 1856.34 | 23-JUL-07:05 | 18.17 |
August | 19980033.94 | 1729.41 | 06-AUG-07:03 | 13.17 |
September | 31645181.45 | 1697.40 | 16-SEP-07:03 | 14.33 |
October | 0.114425E+09 | 1201.95 | 09-OCT-07:03 | 11.17 |
November | 0.328064E+09 | 29667.06 | 29-NOV-08:61 | -0.7 |
December | 0.113276E+10 | 29662.83 | 15-DEC-08:61 | 1.33 |
Annual Sum or Average | 0.369877E+10 | |||
Minimum of Months | 19684961.17 | 1169.55 | -5.7 | |
Maximum of Months | 0.113276E+10 | 29674.75 | 18.17 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.136095E+10 | 29267.45 | 10-JAN-07:01 | -4.3 |
February | 0.907132E+09 | 29119.11 | 26-FEB-08:61 | 1.50 |
March | 0.700001E+09 | 21427.22 | 04-MAR-07:02 | 3.17 |
April | 0.126867E+09 | 5165.74 | 01-APR-06:03 | 3.17 |
May | 93240827.97 | 3204.96 | 06-MAY-06:03 | 3.50 |
June | 28151725.65 | 1563.88 | 27-JUN-06:04 | 15.00 |
July | 29919582.10 | 2087.07 | 22-JUL-17:12 | 29.33 |
August | 16039029.78 | 1637.33 | 06-AUG-07:03 | 13.17 |
September | 33029306.70 | 1615.27 | 02-SEP-06:03 | 13.17 |
October | 0.115934E+09 | 3620.12 | 23-OCT-06:03 | 4.00 |
November | 0.621711E+09 | 28893.28 | 20-NOV-07:02 | 1.00 |
December | 0.168625E+10 | 29266.91 | 26-DEC-07:01 | 1.83 |
Annual Sum or Average | 0.571922E+10 | |||
Minimum of Months | 16039029.78 | 1563.88 | -4.3 | |
Maximum of Months | 0.168625E+10 | 29267.45 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.155440E+10 | 29776.15 | 10-JAN-07:01 | -4.3 |
February | 0.108357E+10 | 29623.88 | 26-FEB-08:61 | 1.50 |
March | 0.851417E+09 | 26204.28 | 06-MAR-07:02 | 4.33 |
April | 0.149150E+09 | 7997.28 | 02-APR-07:03 | 5.17 |
May | 99268993.41 | 5855.91 | 06-MAY-06:03 | 3.50 |
June | 35471704.74 | 1540.69 | 27-JUN-06:04 | 15.00 |
July | 33264476.28 | 2092.40 | 22-JUL-17:12 | 29.33 |
August | 14543835.79 | 1590.68 | 06-AUG-07:03 | 13.17 |
September | 40602342.28 | 1575.30 | 02-SEP-06:03 | 13.17 |
October | 0.135718E+09 | 7755.08 | 23-OCT-06:03 | 4.00 |
November | 0.765386E+09 | 29395.17 | 20-NOV-07:02 | 1.00 |
December | 0.190015E+10 | 29776.52 | 26-DEC-07:01 | 1.83 |
Annual Sum or Average | 0.666295E+10 | |||
Minimum of Months | 14543835.79 | 1540.69 | -4.3 | |
Maximum of Months | 0.190015E+10 | 29776.52 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.180447E+10 | 29120.48 | 10-JAN-07:01 | -4.3 |
February | 0.131248E+10 | 28973.27 | 20-FEB-08:61 | 1.33 |
March | 0.105663E+10 | 28437.93 | 27-MAR-06:02 | 0.33 |
April | 0.176326E+09 | 10843.54 | 02-APR-07:03 | 5.17 |
May | 0.111561E+09 | 8680.89 | 06-MAY-06:03 | 3.50 |
June | 48631865.09 | 1436.10 | 27-JUN-06:04 | 15.00 |
July | 37993112.70 | 2090.29 | 22-JUL-17:12 | 29.33 |
August | 12960646.29 | 1469.06 | 06-AUG-07:03 | 13.17 |
September | 53801620.09 | 1461.89 | 02-SEP-06:03 | 13.17 |
October | 0.173728E+09 | 10952.38 | 23-OCT-06:03 | 4.00 |
November | 0.941063E+09 | 28751.21 | 20-NOV-07:02 | 1.00 |
December | 0.218288E+10 | 29121.03 | 26-DEC-07:01 | 1.83 |
Annual Sum or Average | 0.791252E+10 | |||
Minimum of Months | 12960646.29 | 1436.10 | -4.3 | |
Maximum of Months | 0.218288E+10 | 29121.03 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.413426E+10 | 53973.51 | 31-JAN-08:61 | 1.17 |
February | 0.310409E+10 | 53975.69 | 17-FEB-08:61 | -2.3 |
March | 0.265208E+10 | 53969.55 | 03-MAR-08:61 | 3.17 |
April | 0.461501E+09 | 53918.52 | 11-APR-07:01 | 7.00 |
May | 0.292680E+09 | 53909.83 | 05-MAY-07:01 | 7.17 |
June | 0.138811E+09 | 2227.12 | 27-JUN-07:04 | 15.00 |
July | 97564275.70 | 3907.83 | 22-JUL-17:12 | 29.33 |
August | 59159569.89 | 2225.01 | 17-AUG-07:04 | 15.17 |
September | 0.143211E+09 | 2143.30 | 16-SEP-07:03 | 14.33 |
October | 0.598156E+09 | 53936.09 | 23-OCT-07:01 | 4.50 |
November | 0.237906E+10 | 53983.96 | 20-NOV-08:61 | 1.33 |
December | 0.486267E+10 | 53959.30 | 18-DEC-08:61 | 1.00 |
Annual Sum or Average | 0.189232E+11 | |||
Minimum of Months | 59159569.89 | 2143.30 | -2.3 | |
Maximum of Months | 0.486267E+10 | 53983.96 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.253167E+10 | 25600.03 | 29-JAN-09:01 | 11.00 |
February | 0.194190E+10 | 24788.22 | 22-FEB-08:61 | 7.17 |
March | 0.170191E+10 | 25488.53 | 09-MAR-08:61 | 10.17 |
April | 0.284310E+09 | 24875.48 | 09-APR-08:61 | 8.00 |
May | 0.155250E+09 | 25046.01 | 16-MAY-07:01 | 9.83 |
June | 3063036.39 | 6974.19 | 08-JUN-07:01 | 10.17 |
July | 6925503.46 | 2038.27 | 22-JUL-17:12 | 29.33 |
August | 1118975.72 | 690.25 | 20-AUG-16:03 | 23.67 |
September | 390338.10 | 273.23 | 24-SEP-16:03 | 21.83 |
October | 0.377064E+09 | 24896.35 | 29-OCT-08:61 | 8.17 |
November | 0.151817E+10 | 25189.83 | 24-NOV-08:61 | 11.00 |
December | 0.293100E+10 | 24894.63 | 24-DEC-09:01 | 7.00 |
Annual Sum or Average | 0.114528E+11 | |||
Minimum of Months | 390338.10 | 273.23 | 7.00 | |
Maximum of Months | 0.293100E+10 | 25600.03 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.261885E+10 | 25439.63 | 29-JAN-09:01 | 11.00 |
February | 0.201606E+10 | 24628.73 | 22-FEB-08:61 | 7.17 |
March | 0.178144E+10 | 25326.28 | 09-MAR-08:61 | 10.17 |
April | 0.317999E+09 | 24715.30 | 09-APR-08:61 | 8.00 |
May | 0.189831E+09 | 24893.14 | 16-MAY-07:01 | 9.83 |
June | 4921055.58 | 11616.58 | 08-JUN-07:01 | 10.17 |
July | 7489269.52 | 2034.41 | 22-JUL-17:12 | 29.33 |
August | 1140245.10 | 691.22 | 20-AUG-16:03 | 23.67 |
September | 435399.05 | 278.04 | 24-SEP-16:03 | 21.83 |
October | 0.422567E+09 | 24733.67 | 29-OCT-08:61 | 8.17 |
November | 0.159124E+10 | 25033.95 | 24-NOV-08:61 | 11.00 |
December | 0.301004E+10 | 24732.91 | 24-DEC-09:01 | 7.00 |
Annual Sum or Average | 0.119620E+11 | |||
Minimum of Months | 435399.05 | 278.04 | 7.00 | |
Maximum of Months | 0.301004E+10 | 25439.63 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.295017E+10 | 25158.99 | 29-JAN-09:01 | 11.00 |
February | 0.231707E+10 | 24357.58 | 22-FEB-08:61 | 7.17 |
March | 0.208746E+10 | 25050.42 | 09-MAR-08:61 | 10.17 |
April | 0.438316E+09 | 24470.91 | 24-APR-07:01 | 10.00 |
May | 0.305720E+09 | 24630.06 | 16-MAY-07:01 | 9.83 |
June | 14365819.60 | 21596.47 | 08-JUN-07:01 | 10.17 |
July | 10425255.86 | 5363.63 | 05-JUL-07:02 | 12.17 |
August | 1248568.21 | 694.88 | 20-AUG-16:03 | 23.67 |
September | 810677.11 | 346.59 | 09-SEP-07:09 | 11.33 |
October | 0.563331E+09 | 24444.92 | 29-OCT-08:61 | 8.17 |
November | 0.182766E+10 | 24760.95 | 24-NOV-08:61 | 11.00 |
December | 0.333736E+10 | 24453.77 | 24-DEC-09:01 | 7.00 |
Annual Sum or Average | 0.138539E+11 | |||
Minimum of Months | 810677.11 | 346.59 | 7.00 | |
Maximum of Months | 0.333736E+10 | 25158.99 | 23.67 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.424112E+10 | 24776.08 | 29-JAN-09:01 | 11.00 |
February | 0.355218E+10 | 24001.24 | 22-FEB-08:61 | 7.17 |
March | 0.330018E+10 | 24717.43 | 09-MAR-08:61 | 10.17 |
April | 0.940686E+09 | 24156.39 | 24-APR-07:01 | 10.00 |
May | 0.796104E+09 | 24571.40 | 31-MAY-07:02 | 13.00 |
June | 99477405.88 | 24152.80 | 08-JUN-07:01 | 10.17 |
July | 36992607.43 | 24424.01 | 03-JUL-07:02 | 13.17 |
August | 2008594.71 | 711.89 | 20-AUG-16:03 | 23.67 |
September | 36297297.14 | 12776.74 | 09-SEP-07:01 | 11.33 |
October | 0.109120E+10 | 24310.48 | 20-OCT-07:02 | 11.97 |
November | 0.275002E+10 | 24310.68 | 24-NOV-08:61 | 11.00 |
December | 0.473644E+10 | 24109.56 | 24-DEC-09:01 | 7.00 |
Annual Sum or Average | 0.215827E+11 | |||
Minimum of Months | 2008594.71 | 711.89 | 7.00 | |
Maximum of Months | 0.473644E+10 | 24776.08 | 23.67 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.136196E+11 | 8262.19 | 01-JAN-10:09 | 0.223514E+10 | 1348.26 | 01-JAN-10:09 |
February | 0.123234E+11 | 8262.19 | 01-FEB-10:09 | 0.202238E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.136478E+11 | 8262.19 | 01-MAR-10:09 | 0.223972E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.132157E+11 | 8262.19 | 01-APR-09:09 | 0.216880E+10 | 1348.26 | 01-APR-09:09 |
May | 0.136196E+11 | 8262.19 | 01-MAY-09:09 | 0.223514E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.132157E+11 | 8262.19 | 01-JUN-09:09 | 0.216880E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.136478E+11 | 8262.19 | 01-JUL-09:09 | 0.223972E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.136196E+11 | 8262.19 | 01-AUG-09:09 | 0.223514E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.132439E+11 | 8262.19 | 01-SEP-09:09 | 0.217339E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.136196E+11 | 8262.19 | 01-OCT-09:09 | 0.223514E+10 | 1348.26 | 01-OCT-09:09 |
November | 0.131593E+11 | 8262.19 | 01-NOV-09:09 | 0.215964E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.136759E+11 | 8262.19 | 01-DEC-10:09 | 0.224431E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.160608E+12 | 0.263573E+11 | ||||
Minimum of Months | 0.123234E+11 | 8262.19 | 0.202238E+10 | 1348.26 | ||
Maximum of Months | 0.136759E+11 | 8262.19 | 0.224431E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.759377E+10 | 4606.69 | 01-JAN-10:09 | 0.111757E+10 | 674.13 | 01-JAN-10:09 |
February | 0.687105E+10 | 4606.69 | 01-FEB-10:09 | 0.101119E+10 | 674.13 | 01-FEB-10:09 |
March | 0.760948E+10 | 4606.69 | 01-MAR-10:09 | 0.111986E+10 | 674.13 | 01-MAR-10:09 |
April | 0.736857E+10 | 4606.69 | 01-APR-09:09 | 0.108440E+10 | 674.13 | 01-APR-09:09 |
May | 0.759377E+10 | 4606.69 | 01-MAY-09:09 | 0.111757E+10 | 674.13 | 01-MAY-09:09 |
June | 0.736857E+10 | 4606.69 | 01-JUN-09:09 | 0.108440E+10 | 674.13 | 01-JUN-09:09 |
July | 0.760948E+10 | 4606.69 | 01-JUL-09:09 | 0.111986E+10 | 674.13 | 01-JUL-09:09 |
August | 0.759377E+10 | 4606.69 | 01-AUG-09:09 | 0.111757E+10 | 674.13 | 01-AUG-09:09 |
September | 0.738428E+10 | 4606.69 | 01-SEP-09:09 | 0.108669E+10 | 674.13 | 01-SEP-09:09 |
October | 0.759377E+10 | 4606.69 | 01-OCT-09:09 | 0.111757E+10 | 674.13 | 01-OCT-09:09 |
November | 0.733715E+10 | 4606.69 | 01-NOV-09:09 | 0.107982E+10 | 674.13 | 01-NOV-09:09 |
December | 0.762519E+10 | 4606.69 | 01-DEC-10:09 | 0.112215E+10 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.895488E+11 | 0.131787E+11 | ||||
Minimum of Months | 0.687105E+10 | 4606.69 | 0.101119E+10 | 674.13 | ||
Maximum of Months | 0.762519E+10 | 4606.69 | 0.112215E+10 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.724555E+10 | 6064.13 | 01-JAN-11:09 | 0.162546E+10 | 1348.26 | 01-JAN-11:09 |
February | 0.656305E+10 | 6064.13 | 01-FEB-10:09 | 0.147229E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.741101E+10 | 6064.13 | 01-MAR-10:09 | 0.166213E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.703184E+10 | 6064.13 | 01-APR-09:09 | 0.157746E+10 | 1348.26 | 01-APR-09:09 |
May | 0.732828E+10 | 6064.13 | 01-MAY-09:09 | 0.164379E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.715593E+10 | 6064.13 | 01-JUN-09:09 | 0.160496E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.720419E+10 | 6064.13 | 01-JUL-09:09 | 0.161629E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.741101E+10 | 6064.13 | 01-AUG-09:09 | 0.166213E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.703184E+10 | 6064.13 | 01-SEP-09:09 | 0.157746E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.724555E+10 | 6064.13 | 01-OCT-10:09 | 0.162546E+10 | 1348.26 | 01-OCT-10:09 |
November | 0.703184E+10 | 6064.13 | 01-NOV-09:09 | 0.157746E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.720419E+10 | 6064.13 | 01-DEC-10:09 | 0.161629E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.858643E+11 | 0.192612E+11 | ||||
Minimum of Months | 0.656305E+10 | 6064.13 | 0.147229E+10 | 1348.26 | ||
Maximum of Months | 0.741101E+10 | 6064.13 | 0.166213E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.624423E+10 |
February | 0.163016E+10 | 0.123234E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566003E+10 |
March | 0.178954E+10 | 0.136478E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.533427E+10 |
April | 0.174484E+10 | 0.132157E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 429135.96 | 0.400320E+10 |
May | 0.179537E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29212.70 | 0.491319E+10 |
June | 0.173447E+10 | 0.132157E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17567346.97 | 0.370633E+10 |
July | 0.181028E+10 | 0.136478E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 77275685.26 | 0.313696E+10 |
August | 0.178501E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10373628.50 | 0.251815E+10 |
September | 0.174937E+10 | 0.132439E+11 | 0.217339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.320841E+10 |
October | 0.180574E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.453439E+10 |
November | 0.174613E+10 | 0.131593E+11 | 0.215964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568746E+10 |
December | 0.181481E+10 | 0.136759E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.707843E+10 |
Annual Sum or Average | 0.212115E+11 | 0.160608E+12 | 0.263573E+11 | 0.105675E+09 | 0.560251E+11 | ||||
Minimum of Months | 0.163016E+10 | 0.123234E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251815E+10 |
Maximum of Months | 0.181481E+10 | 0.136759E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 77275685.26 | 0.707843E+10 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345118E+10 |
February | 0.815075E+09 | 0.687105E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304949E+10 |
March | 0.894769E+09 | 0.760948E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295511E+10 |
April | 0.872416E+09 | 0.736857E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 242297.38 | 0.226265E+10 |
May | 0.897684E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16449.24 | 0.256846E+10 |
June | 0.867232E+09 | 0.736857E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9795493.40 | 0.188267E+10 |
July | 0.905135E+09 | 0.760948E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43251239.20 | 0.154612E+10 |
August | 0.892501E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5775142.97 | 0.124115E+10 |
September | 0.874683E+09 | 0.738428E+10 | 0.108669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162902E+10 |
October | 0.902868E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247219E+10 |
November | 0.873064E+09 | 0.733715E+10 | 0.107982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302874E+10 |
December | 0.907403E+09 | 0.762519E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.371346E+10 |
Annual Sum or Average | 0.106057E+11 | 0.895488E+11 | 0.131787E+11 | 59080622.19 | 0.298002E+11 | ||||
Minimum of Months | 0.815075E+09 | 0.687105E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124115E+10 |
Maximum of Months | 0.907403E+09 | 0.762519E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43251239.20 | 0.371346E+10 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346113E+10 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307830E+10 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295671E+10 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114303.42 | 0.224237E+10 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16444.05 | 0.259199E+10 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9728458.09 | 0.195809E+10 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42284340.43 | 0.163288E+10 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775138.09 | 0.131347E+10 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168614E+10 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.246872E+10 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.305174E+10 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.377850E+10 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 57918684.09 | 0.302201E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131347E+10 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42284340.43 | 0.377850E+10 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345778E+10 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307445E+10 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295280E+10 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114301.90 | 0.221616E+10 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16442.17 | 0.255950E+10 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9729074.64 | 0.194851E+10 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42278852.08 | 0.162810E+10 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775074.96 | 0.131175E+10 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168209E+10 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244103E+10 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304177E+10 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.377127E+10 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 57913745.75 | 0.300852E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131175E+10 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42278852.08 | 0.377127E+10 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345560E+10 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307167E+10 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.294974E+10 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114301.71 | 0.218170E+10 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16441.04 | 0.251762E+10 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9730408.87 | 0.192623E+10 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42304278.74 | 0.161845E+10 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775226.90 | 0.130811E+10 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167354E+10 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240572E+10 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303439E+10 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376590E+10 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 57940657.27 | 0.299087E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130811E+10 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42304278.74 | 0.376590E+10 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.608904E+10 |
February | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.544037E+10 |
March | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.519678E+10 |
April | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 200235.34 | 0.374687E+10 |
May | 0.186509E+10 | 0.732828E+10 | 0.164379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28836.05 | 0.439856E+10 |
June | 0.182945E+10 | 0.715593E+10 | 0.160496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17092015.91 | 0.334833E+10 |
July | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74380949.35 | 0.288228E+10 |
August | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10143099.10 | 0.235734E+10 |
September | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295842E+10 |
October | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.415620E+10 |
November | 0.176881E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539476E+10 |
December | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.670845E+10 |
Annual Sum or Average | 0.218821E+11 | 0.858643E+11 | 0.192612E+11 | 0.101845E+09 | 0.526774E+11 | ||||
Minimum of Months | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235734E+10 |
Maximum of Months | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74380949.35 | 0.670845E+10 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345645E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307373E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.294943E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114465.53 | 0.210255E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16446.19 | 0.242108E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9734221.16 | 0.182088E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42425575.63 | 0.157497E+10 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775595.16 | 0.130065E+10 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162582E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231509E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303501E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.377019E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 58066303.67 | 0.294458E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130065E+10 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42425575.63 | 0.377019E+10 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345572E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307268E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.294883E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114461.76 | 0.209479E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16446.61 | 0.240590E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9734643.92 | 0.179665E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42438740.26 | 0.156168E+10 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775567.20 | 0.129778E+10 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161148E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230179E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303358E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376842E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 58079859.75 | 0.293493E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129778E+10 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42438740.26 | 0.376842E+10 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345284E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306844E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.294638E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 114454.11 | 0.208063E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16542.34 | 0.237838E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9735363.47 | 0.174997E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42467214.90 | 0.153502E+10 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775500.26 | 0.128917E+10 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158105E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227879E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302806E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376116E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 58109075.06 | 0.291499E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128917E+10 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42467214.90 | 0.376116E+10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366961E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338963E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313512E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 115196.14 | 0.226945E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16912.12 | 0.289588E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10102225.98 | 0.210103E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 43919444.07 | 0.191718E+10 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6006166.52 | 0.161459E+10 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187708E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258827E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345569E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433720E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 60159944.83 | 0.332507E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161459E+10 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 43919444.07 | 0.433720E+10 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 8262.19 | 01-JAN-10:09 | 1348.26 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 12937.11 | 11-JAN-18:00 |
February | 2159.72 | 03-FEB-13:09 | 8262.19 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 9734.84 | 24-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 8262.19 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10030.47 | 15-MAR-12:00 |
April | 2159.72 | 01-APR-12:09 | 8262.19 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 48.44 | 30-APR-17:00 | 7100.38 | 10-APR-11:10 |
May | 2159.72 | 05-MAY-12:09 | 8262.19 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 48.69 | 22-MAY-15:00 | 7420.56 | 01-MAY-15:00 |
June | 2159.72 | 02-JUN-12:09 | 8262.19 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1466.65 | 13-JUN-17:00 | 6347.18 | 07-JUN-11:05 |
July | 2159.72 | 01-JUL-12:09 | 8262.19 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.97 | 22-JUL-15:00 | 5557.28 | 04-JUL-14:00 |
August | 2159.72 | 04-AUG-12:09 | 8262.19 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1461.93 | 14-AUG-17:00 | 4036.11 | 30-AUG-17:00 |
September | 2159.72 | 01-SEP-12:09 | 8262.19 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 5804.89 | 30-SEP-11:05 |
October | 2159.72 | 01-OCT-12:09 | 8262.19 | 01-OCT-09:09 | 1348.26 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 6391.07 | 27-OCT-17:00 |
November | 2159.72 | 03-NOV-12:09 | 8262.19 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 10585.24 | 28-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 8262.19 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 12033.60 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4036.11 | |||||
Maximum of Months | 2159.72 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.97 | 12937.11 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 4606.69 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.51 | 11-JAN-18:00 |
February | 1079.86 | 03-FEB-13:09 | 4606.69 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.11 | 24-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 4606.69 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.44 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 4606.69 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.44 | 30-APR-17:00 | 4008.49 | 10-APR-11:10 |
May | 1079.86 | 05-MAY-12:09 | 4606.69 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.42 | 22-MAY-15:00 | 4231.80 | 01-MAY-15:00 |
June | 1079.86 | 02-JUN-12:09 | 4606.69 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.52 | 13-JUN-17:00 | 3794.30 | 07-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 4606.69 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 22-JUL-15:00 | 3266.53 | 04-JUL-14:00 |
August | 1079.86 | 04-AUG-12:09 | 4606.69 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.17 | 14-AUG-17:00 | 2228.34 | 30-AUG-17:00 |
September | 1079.86 | 01-SEP-12:09 | 4606.69 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3367.12 | 08-SEP-11:05 |
October | 1079.86 | 01-OCT-12:09 | 4606.69 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3678.14 | 22-OCT-11:05 |
November | 1079.86 | 03-NOV-12:09 | 4606.69 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.68 | 28-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 4606.69 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.95 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.34 | |||||
Maximum of Months | 1079.86 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 7330.51 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.50 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.11 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.44 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 30-APR-15:00 | 3998.50 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 22-MAY-15:00 | 4216.76 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.51 | 13-JUN-17:00 | 3760.75 | 07-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 22-JUL-15:00 | 3193.31 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.16 | 14-AUG-17:00 | 2228.33 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3348.70 | 08-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.34 | 27-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.67 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.94 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.33 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 7330.50 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.50 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.11 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.44 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 30-APR-15:00 | 3998.50 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.40 | 22-MAY-15:00 | 4204.56 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 13-JUN-17:00 | 3719.40 | 07-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 22-JUL-15:00 | 3158.80 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.16 | 14-AUG-17:00 | 2228.33 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3329.01 | 08-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.33 | 27-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.67 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.94 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.33 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 7330.50 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.50 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.11 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.44 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 30-APR-15:00 | 3998.50 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.40 | 22-MAY-15:00 | 4156.59 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 13-JUN-17:00 | 3619.74 | 07-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 22-JUL-15:00 | 3090.94 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.16 | 14-AUG-17:00 | 2228.33 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3266.86 | 30-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.34 | 27-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.67 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.94 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.33 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.67 | 7330.50 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 6064.13 | 01-JAN-11:09 | 1348.26 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 12840.67 | 11-JAN-18:00 |
February | 2879.63 | 04-FEB-15:09 | 6064.13 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 9633.96 | 24-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 6064.13 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10030.45 | 15-MAR-12:00 |
April | 2879.63 | 01-APR-14:09 | 6064.13 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.91 | 30-APR-15:00 | 7010.38 | 10-APR-11:10 |
May | 2879.63 | 06-MAY-14:09 | 6064.13 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 48.06 | 22-MAY-15:00 | 7102.85 | 01-MAY-15:00 |
June | 2879.63 | 03-JUN-14:09 | 6064.13 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1444.43 | 13-JUN-17:00 | 5880.89 | 07-JUN-11:05 |
July | 2879.63 | 01-JUL-14:09 | 6064.13 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2356.87 | 22-JUL-15:00 | 5057.71 | 04-JUL-14:00 |
August | 2879.63 | 05-AUG-14:09 | 6064.13 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1443.27 | 14-AUG-17:00 | 3918.22 | 30-AUG-17:00 |
September | 2879.63 | 02-SEP-14:09 | 6064.13 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 5687.69 | 30-SEP-11:05 |
October | 2879.63 | 07-OCT-14:09 | 6064.13 | 01-OCT-10:09 | 1348.26 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 6343.43 | 27-OCT-17:00 |
November | 2879.63 | 04-NOV-14:09 | 6064.13 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 10425.16 | 28-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 6064.13 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 11880.09 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3918.22 | |||||
Maximum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2356.87 | 12840.67 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.49 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.10 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.43 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.38 | 30-APR-15:00 | 3998.49 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 22-MAY-15:00 | 3961.94 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 13-JUN-17:00 | 3329.09 | 07-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 22-JUL-15:00 | 2795.72 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.17 | 14-AUG-17:00 | 2228.34 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3224.63 | 30-SEP-11:05 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.34 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.66 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.93 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.34 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 7330.49 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.49 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.10 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.43 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.38 | 30-APR-15:00 | 3998.49 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 22-MAY-15:00 | 3926.38 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 13-JUN-17:00 | 3324.74 | 07-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 22-JUL-15:00 | 2736.44 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.17 | 14-AUG-17:00 | 2228.34 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3207.38 | 30-SEP-11:05 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.34 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.66 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.93 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.34 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 7330.49 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7330.49 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5497.10 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.43 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.37 | 30-APR-15:00 | 3998.49 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.57 | 22-MAY-15:00 | 3877.32 | 01-MAY-13:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 13-JUN-17:00 | 3324.08 | 07-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 22-JUL-15:00 | 2704.54 | 27-JUL-11:05 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 823.16 | 14-AUG-17:00 | 2228.40 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3129.08 | 30-SEP-11:05 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3621.34 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5943.66 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6775.93 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2228.40 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.70 | 7330.49 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7426.79 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5597.83 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5733.43 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.73 | 30-APR-15:00 | 4088.37 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 28.19 | 22-MAY-15:00 | 4145.20 | 01-MAY-13:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 845.63 | 13-JUN-17:00 | 3451.40 | 07-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1379.84 | 22-JUL-15:00 | 2686.59 | 27-JUL-11:05 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 841.78 | 14-AUG-17:00 | 2337.72 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3061.19 | 30-SEP-11:05 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3668.91 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 6103.51 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 6929.22 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2337.72 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1379.84 | 7426.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7728.43 | 13-JAN-00:12 | 719.91 | 17394.09 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.31 |
February | 8423.62 | 17-FEB-00:12 | 719.91 | 17394.09 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 245.11 |
March | 7157.58 | 03-MAR-00:13 | 539.93 | 13045.57 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11270.29 | 30-APR-16:05 | 8638.88 | 33048.78 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 47.57 | 0.00 |
May | 9065.58 | 22-MAY-15:00 | 899.88 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 48.69 | 0.00 |
June | 13080.72 | 13-JUN-17:00 | 1799.77 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1466.65 | 0.00 |
July | 23131.69 | 23-JUL-07:03 | 719.91 | 1739.41 | 299.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 462.75 |
August | 18294.22 | 06-AUG-07:02 | 1079.86 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 763.21 |
September | 17847.79 | 16-SEP-07:02 | 0.00 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 655.69 |
October | 7094.24 | 01-OCT-17:20 | 4319.44 | 16524.39 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1197.42 |
November | 6165.72 | 04-NOV-24:00 | 179.98 | 4348.52 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.95 |
December | 9008.70 | 30-DEC-00:12 | 719.91 | 17394.09 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 468.47 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6165.72 | 0.00 | 1739.41 | 299.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23131.69 | 8638.88 | 33048.78 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 1466.65 | 1197.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3340.79 | 19-JAN-20:20 | 539.93 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3195.56 | 13-FEB-20:40 | 539.93 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.75 |
March | 3261.66 | 10-MAR-21:00 | 539.93 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 19640.35 | 29-APR-18:59 | 7199.04 | 36853.53 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.47 |
May | 18353.81 | 21-MAY-17:11 | 8638.85 | 36853.53 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.25 |
June | 18841.86 | 06-JUN-21:12 | 5399.28 | 46066.91 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.94 |
July | 19164.96 | 30-JUL-21:00 | 4859.35 | 41460.22 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.36 |
August | 19202.92 | 14-AUG-20:46 | 4319.42 | 36853.53 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.22 |
September | 19647.10 | 04-SEP-17:10 | 9718.70 | 41460.22 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.27 |
October | 19002.92 | 04-OCT-20:01 | 4859.35 | 41460.22 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.23 |
November | 3227.49 | 03-NOV-18:00 | 899.88 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 836.47 |
December | 3034.11 | 21-DEC-20:30 | 539.93 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.71 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3034.11 | 539.93 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19647.10 | 9718.70 | 46066.91 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 836.47 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3424.64 | 20-JAN-08:61 | 809.89 | 20133.67 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 789.11 |
February | 3340.56 | 09-FEB-08:61 | 899.88 | 22370.74 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 770.64 |
March | 3612.46 | 21-MAR-07:01 | 809.89 | 20133.67 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 829.51 |
April | 5918.23 | 30-APR-15:00 | 359.95 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 0.00 |
May | 4852.32 | 22-MAY-15:00 | 359.95 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 0.00 |
June | 12468.67 | 27-JUN-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.53 |
July | 17158.12 | 23-JUL-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.03 |
August | 14921.41 | 19-AUG-06:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.44 |
September | 14903.50 | 02-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.38 |
October | 3848.48 | 04-OCT-17:10 | 1799.76 | 8500.88 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 498.72 |
November | 3607.18 | 04-NOV-07:01 | 809.89 | 20133.67 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 894.34 |
December | 3179.83 | 21-DEC-08:61 | 899.88 | 22370.74 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 857.60 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3179.83 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17158.12 | 1799.76 | 22370.74 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 894.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3171.56 | 13-JAN-09:53 | 539.93 | 12751.32 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 772.66 |
February | 2881.10 | 10-FEB-08:61 | 899.88 | 22370.74 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 728.68 |
March | 3521.24 | 21-MAR-07:01 | 809.89 | 20133.67 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 820.11 |
April | 5816.47 | 30-APR-15:00 | 359.95 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 0.00 |
May | 4664.47 | 23-MAY-17:10 | 899.88 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 259.24 |
June | 11725.48 | 27-JUN-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.51 |
July | 17229.62 | 23-JUL-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.75 |
August | 13853.67 | 19-AUG-06:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.44 |
September | 13518.01 | 02-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.38 |
October | 3869.66 | 04-OCT-17:10 | 1799.76 | 8500.88 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 498.66 |
November | 3559.07 | 04-NOV-07:01 | 809.89 | 20133.67 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 886.15 |
December | 3167.78 | 29-DEC-10:43 | 539.93 | 12751.32 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 842.18 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2881.10 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17229.62 | 1799.76 | 22370.74 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 886.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3365.01 | 09-JAN-11:33 | 539.93 | 12751.32 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 882.22 |
February | 2813.89 | 18-FEB-09:33 | 539.93 | 12751.32 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 774.33 |
March | 3186.31 | 15-MAR-09:13 | 539.93 | 12751.32 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 806.43 |
April | 5591.82 | 30-APR-15:00 | 359.95 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 0.00 |
May | 4399.40 | 23-MAY-17:10 | 899.88 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 259.24 |
June | 9277.60 | 27-JUN-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.47 |
July | 16963.23 | 23-JUL-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.95 |
August | 10405.13 | 19-AUG-06:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.43 |
September | 10523.65 | 02-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.38 |
October | 3367.19 | 03-OCT-17:20 | 899.88 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 493.08 |
November | 3114.32 | 16-NOV-08:61 | 629.92 | 15659.52 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 737.46 |
December | 2619.00 | 31-DEC-10:55 | 359.95 | 8500.88 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 675.15 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2619.00 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16963.23 | 899.88 | 15659.52 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 882.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6420.49 | 04-JAN-19:03 | 2807.63 | 18192.39 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1278.81 |
February | 4866.67 | 05-FEB-11:50 | 791.90 | 12128.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1173.25 |
March | 3703.02 | 23-MAR-17:10 | 2447.68 | 12128.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 896.93 |
April | 9375.86 | 30-APR-15:00 | 2483.68 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 47.91 | 0.00 |
May | 6500.95 | 22-MAY-15:00 | 2483.68 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 48.06 | 0.00 |
June | 10831.02 | 13-JUN-17:00 | 2555.67 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1444.43 | 0.00 |
July | 22947.65 | 24-JUL-07:02 | 0.00 | 1914.99 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 776.25 |
August | 10701.32 | 14-AUG-17:00 | 2555.67 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1443.27 | 0.00 |
September | 9751.13 | 13-SEP-14:10 | 2483.68 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 424.96 |
October | 6128.01 | 05-OCT-20:00 | 395.95 | 3191.65 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.50 |
November | 3693.42 | 25-NOV-11:40 | 2087.73 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1119.99 |
December | 6116.26 | 13-DEC-20:43 | 1187.85 | 9574.94 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.14 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3693.42 | 0.00 | 1914.99 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22947.65 | 2807.63 | 18192.39 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 1444.43 | 1278.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4804.32 | 12-JAN-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1015.53 |
February | 4936.71 | 17-FEB-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 986.11 |
March | 4072.50 | 21-MAR-07:03 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 827.61 |
April | 4716.38 | 30-APR-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.38 | 0.00 |
May | 3193.57 | 22-MAY-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 0.00 |
June | 5542.40 | 13-JUN-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 0.00 |
July | 9998.34 | 24-JUL-07:02 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 437.04 |
August | 5521.29 | 14-AUG-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.17 | 0.00 |
September | 4886.56 | 13-SEP-14:20 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.17 |
October | 3457.04 | 23-OCT-07:03 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 761.24 |
November | 4497.33 | 29-NOV-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1015.24 |
December | 4602.81 | 27-DEC-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 983.69 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3193.57 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 9998.34 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 1015.53 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5329.49 | 10-JAN-08:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1141.77 |
February | 4542.14 | 17-FEB-20:53 | 791.89 | 6383.30 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.97 |
March | 4137.45 | 21-MAR-07:03 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 829.65 |
April | 4569.13 | 30-APR-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.38 | 0.00 |
May | 3040.80 | 22-MAY-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.41 | 0.00 |
June | 5406.03 | 13-JUN-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 0.00 |
July | 8912.86 | 23-JUL-08:63 | 0.00 | 478.75 | 112.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 206.28 |
August | 5411.81 | 14-AUG-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.17 | 0.00 |
September | 4770.87 | 13-SEP-14:20 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.17 |
October | 3440.37 | 23-OCT-07:03 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 756.98 |
November | 4566.53 | 29-NOV-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.68 |
December | 4144.05 | 31-DEC-09:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 905.73 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3040.80 | 0.00 | 478.75 | 112.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8912.86 | 1277.83 | 6383.30 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 1141.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5250.27 | 11-JAN-08:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1109.69 |
February | 4349.42 | 18-FEB-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 929.73 |
March | 4142.34 | 21-MAR-07:03 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 821.22 |
April | 4280.43 | 30-APR-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.37 | 0.00 |
May | 2911.41 | 06-MAY-07:03 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 665.08 |
June | 5154.19 | 13-JUN-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 0.00 |
July | 7009.31 | 23-JUL-08:63 | 0.00 | 478.75 | 112.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205.42 |
August | 5181.58 | 14-AUG-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.16 | 0.00 |
September | 4562.47 | 13-SEP-14:20 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.18 |
October | 3386.01 | 12-OCT-07:04 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 773.05 |
November | 4162.98 | 04-NOV-07:03 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 889.96 |
December | 4206.26 | 08-DEC-08:04 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 948.42 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2911.41 | 0.00 | 478.75 | 112.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 7009.31 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 823.50 | 1109.69 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4029.61 | 02-JAN-08:06 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 834.07 |
February | 4058.75 | 25-FEB-08:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 820.61 |
March | 3837.29 | 15-MAR-07:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 814.95 |
April | 3736.41 | 30-APR-15:00 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 27.73 | 0.00 |
May | 2995.66 | 06-MAY-07:04 | 0.00 | 1436.24 | 337.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 746.71 |
June | 4700.85 | 13-JUN-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 845.63 | 0.00 |
July | 6452.51 | 22-JUL-15:00 | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1379.84 | 0.00 |
August | 4714.28 | 14-AUG-17:00 | 1277.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 841.78 | 0.00 |
September | 4183.61 | 13-SEP-14:10 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 249.73 |
October | 3654.56 | 06-OCT-07:05 | 0.00 | 638.33 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 717.18 |
November | 3990.46 | 28-NOV-08:06 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1141.56 |
December | 3633.75 | 21-DEC-08:05 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1025.79 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2995.66 | 0.00 | 638.33 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6452.51 | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1379.84 | 1141.56 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.106923E+12 | 83790.23 | 12-JAN-17:00 | 0.809580E+11 | 170020.52 | 10-JAN-08:09 |
February | 0.958172E+11 | 81665.73 | 02-FEB-19:19 | 0.657345E+11 | 145515.35 | 17-FEB-08:09 |
March | 0.105945E+12 | 79553.23 | 07-MAR-18:49 | 0.571416E+11 | 123028.67 | 15-MAR-11:00 |
April | 0.100722E+12 | 89039.08 | 30-APR-14:30 | 0.125118E+11 | 77614.61 | 01-APR-07:10 |
May | 0.103157E+12 | 88205.03 | 22-MAY-14:30 | 0.853991E+10 | 61556.05 | 05-MAY-07:10 |
June | 0.102428E+12 | 97517.77 | 13-JUN-16:40 | 0.586689E+09 | 23814.59 | 08-JUN-07:10 |
July | 0.106613E+12 | 103313.61 | 22-JUL-15:39 | 98008865.88 | 10216.62 | 05-JUL-07:10 |
August | 0.109702E+12 | 93579.29 | 14-AUG-16:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.104137E+12 | 90746.31 | 13-SEP-14:39 | 0.179841E+09 | 7005.23 | 07-SEP-07:10 |
October | 0.105307E+12 | 79544.60 | 23-OCT-17:49 | 0.139799E+11 | 82216.05 | 23-OCT-07:10 |
November | 0.103164E+12 | 81666.00 | 21-NOV-18:10 | 0.495758E+11 | 133347.09 | 29-NOV-08:09 |
December | 0.107007E+12 | 81185.92 | 16-DEC-16:30 | 0.883929E+11 | 149412.14 | 31-DEC-09:09 |
Annual Sum or Average | 0.125092E+13 | 0.377699E+12 | ||||
Minimum of Months | 0.958172E+11 | 79544.60 | 0.00 | 0.00 | ||
Maximum of Months | 0.109702E+12 | 103313.61 | 0.883929E+11 | 170020.52 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.595337E+11 | 0.120823E+11 | 0.108804E+11 | 0.00 | 0.188089E+11 | 0.00 | 0.00 | 7301.09 | 0.00 | 0.00 | 0.00 | 0.561724E+10 | 0.00 |
February | 0.539017E+11 | 0.994245E+10 | 0.985143E+10 | 0.00 | 0.170265E+11 | 0.00 | 0.00 | 3552.48 | 0.00 | 0.00 | 0.00 | 0.509518E+10 | 0.00 |
March | 0.604219E+11 | 0.967602E+10 | 0.110523E+11 | 0.00 | 0.191277E+11 | 0.00 | 0.00 | 86742.66 | 0.00 | 0.00 | 0.00 | 0.566729E+10 | 0.00 |
April | 0.577706E+11 | 0.801824E+10 | 0.105581E+11 | 0.00 | 0.183920E+11 | 0.00 | 0.00 | 0.585319E+09 | 0.00 | 0.00 | 0.00 | 0.539746E+10 | 0.00 |
May | 0.599558E+11 | 0.710477E+10 | 0.109629E+11 | 0.00 | 0.191676E+11 | 0.00 | 0.00 | 0.423976E+09 | 0.00 | 0.00 | 0.00 | 0.554238E+10 | 0.00 |
June | 0.584038E+11 | 0.624628E+10 | 0.106818E+11 | 0.00 | 0.189260E+11 | 0.00 | 0.00 | 0.285515E+10 | 0.00 | 0.00 | 0.00 | 0.531495E+10 | 0.00 |
July | 0.593665E+11 | 0.673262E+10 | 0.108460E+11 | 0.00 | 0.192304E+11 | 0.00 | 0.00 | 0.502841E+10 | 0.00 | 0.00 | 0.00 | 0.540901E+10 | 0.00 |
August | 0.603780E+11 | 0.776027E+10 | 0.110454E+11 | 0.00 | 0.195964E+11 | 0.00 | 0.00 | 0.547722E+10 | 0.00 | 0.00 | 0.00 | 0.544477E+10 | 0.00 |
September | 0.578145E+11 | 0.877947E+10 | 0.105649E+11 | 0.00 | 0.187341E+11 | 0.00 | 0.00 | 0.299094E+10 | 0.00 | 0.00 | 0.00 | 0.525342E+10 | 0.00 |
October | 0.595337E+11 | 0.104542E+11 | 0.108804E+11 | 0.00 | 0.189377E+11 | 0.00 | 0.00 | 13724315.88 | 0.00 | 0.00 | 0.00 | 0.548689E+10 | 0.00 |
November | 0.576828E+11 | 0.113253E+11 | 0.105443E+11 | 0.00 | 0.182450E+11 | 0.00 | 0.00 | 210299.19 | 0.00 | 0.00 | 0.00 | 0.536618E+10 | 0.00 |
December | 0.594104E+11 | 0.124080E+11 | 0.108529E+11 | 0.00 | 0.187420E+11 | 0.00 | 0.00 | 6979.10 | 0.00 | 0.00 | 0.00 | 0.559364E+10 | 0.00 |
Annual Sum or Average | 0.704173E+12 | 0.110530E+12 | 0.128721E+12 | 0.224934E+12 | 0.00 | 0.173751E+11 | 0.651884E+11 | ||||||
Minimum of Months | 0.539017E+11 | 0.624628E+10 | 0.985143E+10 | 0.00 | 0.170265E+11 | 0.00 | 0.00 | 3552.48 | 0.00 | 0.00 | 0.00 | 0.509518E+10 | 0.00 |
Maximum of Months | 0.604219E+11 | 0.124080E+11 | 0.110523E+11 | 0.00 | 0.195964E+11 | 0.00 | 0.00 | 0.547722E+10 | 0.00 | 0.00 | 0.00 | 0.566729E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.809580E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.657345E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.571416E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.125118E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.853991E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.586689E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 98008865.88 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.179841E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.139799E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.495758E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.883929E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.377699E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.883929E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 43812.60 | 01-JAN-11:09 | 7048.38 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:09 | 0.00 | 13026.81 | 01-JAN-09:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 43812.60 | 01-FEB-10:09 | 7048.38 | 01-FEB-00:10 | 8089.53 | 01-FEB-10:09 | 0.00 | 13026.81 | 01-FEB-08:20 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 43812.60 | 01-MAR-10:09 | 7048.38 | 01-MAR-00:10 | 8089.53 | 01-MAR-10:09 | 0.00 | 13026.81 | 01-MAR-08:20 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 43812.60 | 01-APR-09:09 | 7048.38 | 01-APR-00:10 | 8089.53 | 01-APR-09:09 | 0.00 | 13026.81 | 01-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 43812.60 | 01-MAY-09:09 | 7048.38 | 01-MAY-00:10 | 8089.53 | 01-MAY-09:09 | 0.00 | 13026.81 | 01-MAY-07:19 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 43812.60 | 01-JUN-09:09 | 7048.38 | 01-JUN-00:10 | 8089.53 | 01-JUN-09:09 | 0.00 | 13026.81 | 01-JUN-07:40 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 43812.60 | 01-JUL-09:09 | 7048.38 | 01-JUL-00:10 | 8089.53 | 01-JUL-09:09 | 0.00 | 13026.81 | 01-JUL-07:49 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 43812.60 | 01-AUG-09:09 | 7048.38 | 01-AUG-00:10 | 8089.53 | 01-AUG-09:09 | 0.00 | 13026.81 | 01-AUG-09:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 43812.60 | 01-SEP-09:09 | 7048.38 | 01-SEP-00:10 | 8089.53 | 01-SEP-09:09 | 0.00 | 13026.81 | 01-SEP-07:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 43812.60 | 01-OCT-10:09 | 7048.38 | 01-OCT-00:10 | 8089.53 | 01-OCT-10:09 | 0.00 | 13026.81 | 01-OCT-11:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 43812.60 | 01-NOV-09:09 | 7048.38 | 01-NOV-00:10 | 8089.53 | 01-NOV-09:09 | 0.00 | 13026.81 | 01-NOV-07:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 43812.60 | 01-DEC-10:09 | 7048.38 | 01-DEC-00:10 | 8089.53 | 01-DEC-10:09 | 0.00 | 13026.81 | 01-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 43812.60 | 7048.38 | 8089.53 | 0.00 | 13026.81 | 0.00 | 0.00 | |||||
Maximum of Months | 43812.60 | 7048.38 | 8089.53 | 0.00 | 13026.81 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 6.22 | 18-JAN-23:10 | 0.00 | 0.00 | 0.00 | 11847.86 | 04-JAN-12:00 | 0.00 |
February | 5.92 | 11-FEB-23:00 | 0.00 | 0.00 | 0.00 | 9740.65 | 18-FEB-13:50 | 0.00 |
March | 49.42 | 25-MAR-23:19 | 0.00 | 0.00 | 0.00 | 9715.65 | 18-MAR-13:09 | 0.00 |
April | 19820.82 | 30-APR-14:00 | 0.00 | 0.00 | 0.00 | 9731.56 | 29-APR-12:39 | 0.00 |
May | 17135.18 | 22-MAY-14:00 | 0.00 | 0.00 | 0.00 | 9727.63 | 20-MAY-12:39 | 0.00 |
June | 27209.60 | 13-JUN-16:00 | 0.00 | 0.00 | 0.00 | 9138.39 | 29-JUN-15:20 | 0.00 |
July | 30930.12 | 22-JUL-14:00 | 0.00 | 0.00 | 0.00 | 9694.58 | 28-JUL-11:09 | 0.00 |
August | 25315.13 | 14-AUG-16:00 | 0.00 | 0.00 | 0.00 | 9715.62 | 26-AUG-12:20 | 0.00 |
September | 20464.93 | 13-SEP-14:09 | 0.00 | 0.00 | 0.00 | 9627.61 | 22-SEP-09:09 | 0.00 |
October | 2268.93 | 07-OCT-14:00 | 0.00 | 0.00 | 0.00 | 9196.38 | 22-OCT-10:00 | 0.00 |
November | 100.07 | 08-NOV-23:40 | 0.00 | 0.00 | 0.00 | 11858.20 | 21-NOV-13:39 | 0.00 |
December | 5.37 | 24-DEC-22:00 | 0.00 | 0.00 | 0.00 | 10319.39 | 18-DEC-13:39 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 5.37 | 0.00 | 0.00 | 0.00 | 9138.39 | 0.00 | ||
Maximum of Months | 30930.12 | 0.00 | 0.00 | 0.00 | 11858.20 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 83790.23 | 12-JAN-17:00 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 81665.73 | 02-FEB-19:19 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 79553.23 | 07-MAR-18:49 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 89039.08 | 30-APR-14:30 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 18673.51 | 0.00 |
May | 88205.03 | 22-MAY-14:30 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 15802.23 | 0.00 |
June | 97517.77 | 13-JUN-16:40 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 27139.76 | 0.00 |
July | 103313.61 | 22-JUL-15:39 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 30820.36 | 0.00 |
August | 93579.29 | 14-AUG-16:00 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 25315.13 | 0.00 |
September | 90746.31 | 13-SEP-14:39 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 20361.42 | 0.00 |
October | 79544.60 | 23-OCT-17:49 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 81666.00 | 21-NOV-18:10 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 81185.92 | 16-DEC-16:30 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 79544.60 | 43812.60 | 8089.53 | 0.00 | 0.00 | 13026.81 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 103313.61 | 43812.60 | 8089.53 | 7048.38 | 0.00 | 13026.81 | 0.00 | 0.00 | 30820.36 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 170020.52 | 10-JAN-08:09 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 145515.35 | 17-FEB-08:09 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 123028.67 | 15-MAR-11:00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 77614.61 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 61556.05 | 05-MAY-07:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 23814.59 | 08-JUN-07:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 10216.62 | 05-JUL-07:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 7005.23 | 07-SEP-07:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 82216.05 | 23-OCT-07:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 133347.09 | 29-NOV-08:09 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 149412.14 | 31-DEC-09:09 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 170020.52 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.33 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.33 | 20.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.83 | 20.52 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 20.53 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.67 | 20.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.83 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.67 | 20.48 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.33 | 20.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3.83 | 20.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 2.67 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.67 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 4.50 | 20.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 16.17 | 20.28 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4.50 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.10 | 62.67 | 21.00 | 62.67 | 21.00 |
February | 448.00 | 21.08 | 39.33 | 20.85 | 39.33 | 20.85 |
March | 496.00 | 21.13 | 35.17 | 20.98 | 35.17 | 20.98 |
April | 399.50 | 21.86 | 21.50 | 23.52 | 2.83 | 21.10 |
May | 386.67 | 22.06 | 47.00 | 23.89 | 0.00 | 0.00 |
June | 94.67 | 23.01 | 230.17 | 23.87 | 0.00 | 0.00 |
July | 34.33 | 23.47 | 342.17 | 23.89 | 0.00 | 0.00 |
August | 23.50 | 23.80 | 376.33 | 23.89 | 0.00 | 0.00 |
September | 58.50 | 23.34 | 252.00 | 23.88 | 0.00 | 0.00 |
October | 399.50 | 21.86 | 1.33 | 23.59 | 0.17 | 21.49 |
November | 480.00 | 21.18 | 18.33 | 21.07 | 18.33 | 21.07 |
December | 496.00 | 21.08 | 62.50 | 20.93 | 62.50 | 20.93 |
Annual Sum or Average | 3812.67 | 21.49 | 1488.50 | 23.45 | 221.00 | 20.96 |
Minimum of Months | 23.50 | 21.08 | 1.33 | 20.85 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.80 | 376.33 | 23.89 | 62.67 | 21.49 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.73 | 11.17 | 21.13 | 11.17 | 21.13 |
February | 448.00 | 21.69 | 2.33 | 21.35 | 2.33 | 21.35 |
March | 496.00 | 21.81 | 0.83 | 21.37 | 0.83 | 21.37 |
April | 345.50 | 22.65 | 21.50 | 23.89 | 0.00 | 0.00 |
May | 309.67 | 22.74 | 56.00 | 23.89 | 0.00 | 0.00 |
June | 34.67 | 23.29 | 302.17 | 23.88 | 0.00 | 0.00 |
July | 12.00 | 23.75 | 380.17 | 23.88 | 0.00 | 0.00 |
August | 4.00 | 23.87 | 400.83 | 23.88 | 0.00 | 0.00 |
September | 33.83 | 23.65 | 304.50 | 23.88 | 0.00 | 0.00 |
October | 331.00 | 22.50 | 22.17 | 23.85 | 0.00 | 0.00 |
November | 480.00 | 21.93 | 3.17 | 21.16 | 3.17 | 21.16 |
December | 496.00 | 21.66 | 10.50 | 21.18 | 10.50 | 21.18 |
Annual Sum or Average | 3486.67 | 22.05 | 1515.33 | 23.83 | 28.00 | 21.18 |
Minimum of Months | 4.00 | 21.66 | 0.83 | 21.13 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.87 | 400.83 | 23.89 | 11.17 | 21.37 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.13 | 22.17 | 21.11 | 22.17 | 21.11 |
February | 336.00 | 21.12 | 10.50 | 21.11 | 10.50 | 21.11 |
March | 379.00 | 21.16 | 7.83 | 21.11 | 7.83 | 21.11 |
April | 288.17 | 22.04 | 18.50 | 24.11 | 0.00 | 0.00 |
May | 276.33 | 22.22 | 51.50 | 23.95 | 0.00 | 0.00 |
June | 44.83 | 23.09 | 226.83 | 23.96 | 0.00 | 0.00 |
July | 12.50 | 23.50 | 287.17 | 24.00 | 0.17 | 28.28 |
August | 5.67 | 23.64 | 310.83 | 24.00 | 0.00 | 0.00 |
September | 34.83 | 23.26 | 226.83 | 23.95 | 0.00 | 0.00 |
October | 285.33 | 21.89 | 1.33 | 23.89 | 0.00 | 0.00 |
November | 360.00 | 21.21 | 4.33 | 21.11 | 4.33 | 21.11 |
December | 369.00 | 21.11 | 23.33 | 21.11 | 23.33 | 21.11 |
Annual Sum or Average | 2762.67 | 21.50 | 1191.17 | 23.82 | 68.33 | 21.13 |
Minimum of Months | 5.67 | 21.11 | 1.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.64 | 310.83 | 24.11 | 23.33 | 28.28 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.12 | 31.67 | 21.11 | 31.67 | 21.11 |
February | 336.00 | 21.11 | 16.00 | 21.11 | 16.00 | 21.11 |
March | 379.00 | 21.14 | 12.17 | 21.11 | 12.17 | 21.11 |
April | 293.17 | 21.92 | 17.17 | 24.09 | 0.17 | 21.11 |
May | 284.17 | 22.10 | 48.33 | 23.95 | 0.00 | 0.00 |
June | 55.17 | 23.07 | 219.83 | 23.95 | 0.00 | 0.00 |
July | 16.17 | 23.41 | 282.83 | 24.00 | 0.17 | 28.28 |
August | 6.67 | 23.62 | 310.00 | 24.00 | 0.00 | 0.00 |
September | 36.83 | 23.23 | 213.67 | 23.95 | 0.00 | 0.00 |
October | 296.17 | 21.81 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 360.00 | 21.18 | 7.67 | 21.11 | 7.67 | 21.11 |
December | 369.00 | 21.11 | 34.17 | 21.11 | 34.17 | 21.11 |
Annual Sum or Average | 2803.33 | 21.47 | 1193.50 | 23.73 | 102.00 | 21.12 |
Minimum of Months | 6.67 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.62 | 310.00 | 24.09 | 34.17 | 28.28 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 43.00 | 21.11 | 43.00 | 21.11 |
February | 336.00 | 21.11 | 23.83 | 21.11 | 23.83 | 21.11 |
March | 379.00 | 21.13 | 18.33 | 21.11 | 18.33 | 21.11 |
April | 304.00 | 21.79 | 14.50 | 24.00 | 0.67 | 21.11 |
May | 295.00 | 21.95 | 42.17 | 23.93 | 0.00 | 0.00 |
June | 76.00 | 22.97 | 190.83 | 23.95 | 0.00 | 0.00 |
July | 30.83 | 23.30 | 266.50 | 24.00 | 0.17 | 28.21 |
August | 12.67 | 23.59 | 301.17 | 23.99 | 0.00 | 0.00 |
September | 44.00 | 23.16 | 196.33 | 23.94 | 0.00 | 0.00 |
October | 310.17 | 21.71 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 360.00 | 21.15 | 12.67 | 21.11 | 12.67 | 21.11 |
December | 369.00 | 21.11 | 47.17 | 21.11 | 47.17 | 21.11 |
Annual Sum or Average | 2887.67 | 21.45 | 1156.50 | 23.61 | 145.83 | 21.12 |
Minimum of Months | 12.67 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.59 | 301.17 | 24.00 | 47.17 | 28.21 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 86.00 | 21.11 | 86.00 | 21.11 |
February | 308.00 | 21.11 | 33.33 | 21.11 | 33.33 | 21.11 |
March | 348.00 | 21.11 | 32.67 | 21.11 | 32.67 | 21.11 |
April | 293.83 | 21.52 | 7.17 | 23.38 | 2.33 | 21.11 |
May | 287.50 | 21.63 | 19.83 | 23.88 | 0.00 | 0.00 |
June | 127.83 | 22.67 | 99.67 | 23.89 | 0.00 | 0.00 |
July | 49.00 | 23.00 | 210.50 | 23.92 | 0.17 | 27.95 |
August | 14.50 | 23.58 | 248.17 | 23.92 | 0.00 | 0.00 |
September | 63.67 | 23.07 | 130.50 | 23.90 | 0.00 | 0.00 |
October | 333.50 | 21.65 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 330.00 | 21.11 | 18.33 | 21.11 | 18.33 | 21.11 |
December | 338.00 | 21.11 | 89.00 | 21.11 | 89.00 | 21.11 |
Annual Sum or Average | 2833.83 | 21.43 | 975.17 | 23.16 | 261.83 | 21.11 |
Minimum of Months | 14.50 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.58 | 248.17 | 23.92 | 89.00 | 27.95 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 90.67 | 21.11 | 90.67 | 21.11 |
February | 308.00 | 21.11 | 37.17 | 21.11 | 37.17 | 21.11 |
March | 348.00 | 21.11 | 38.67 | 21.11 | 38.67 | 21.11 |
April | 298.67 | 21.49 | 5.33 | 22.37 | 3.83 | 21.11 |
May | 297.67 | 21.59 | 7.83 | 23.89 | 0.00 | 0.00 |
June | 171.50 | 22.60 | 65.00 | 23.92 | 0.00 | 0.00 |
July | 75.50 | 22.89 | 179.33 | 23.93 | 0.00 | 0.00 |
August | 28.33 | 23.37 | 217.17 | 23.92 | 0.00 | 0.00 |
September | 101.83 | 22.99 | 99.83 | 23.92 | 0.00 | 0.00 |
October | 336.17 | 21.58 | 0.33 | 21.11 | 0.33 | 21.11 |
November | 330.00 | 21.11 | 21.17 | 21.11 | 21.17 | 21.11 |
December | 338.00 | 21.11 | 93.67 | 21.11 | 93.67 | 21.11 |
Annual Sum or Average | 2973.67 | 21.47 | 856.17 | 22.99 | 285.50 | 21.11 |
Minimum of Months | 28.33 | 21.11 | 0.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.37 | 217.17 | 23.93 | 93.67 | 21.11 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 98.17 | 21.11 | 98.17 | 21.11 |
February | 308.00 | 21.11 | 40.17 | 21.11 | 40.17 | 21.11 |
March | 348.00 | 21.11 | 43.33 | 21.11 | 43.33 | 21.11 |
April | 305.00 | 21.50 | 6.17 | 22.19 | 4.67 | 21.11 |
May | 301.83 | 21.57 | 6.50 | 23.89 | 0.00 | 0.00 |
June | 191.83 | 22.54 | 54.50 | 23.93 | 0.00 | 0.00 |
July | 85.17 | 22.81 | 168.67 | 23.93 | 0.00 | 0.00 |
August | 33.33 | 23.35 | 209.83 | 23.92 | 0.00 | 0.00 |
September | 117.17 | 22.93 | 91.33 | 23.92 | 0.00 | 0.00 |
October | 337.17 | 21.53 | 0.33 | 21.11 | 0.33 | 21.11 |
November | 330.00 | 21.11 | 23.00 | 21.11 | 23.00 | 21.11 |
December | 338.00 | 21.11 | 101.83 | 21.11 | 101.83 | 21.11 |
Annual Sum or Average | 3035.50 | 21.47 | 843.83 | 22.89 | 311.50 | 21.11 |
Minimum of Months | 33.33 | 21.11 | 0.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.35 | 209.83 | 23.93 | 101.83 | 21.11 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 121.83 | 21.11 | 121.83 | 21.11 |
February | 308.00 | 21.11 | 53.00 | 21.11 | 53.00 | 21.11 |
March | 348.00 | 21.11 | 55.83 | 21.11 | 55.83 | 21.11 |
April | 308.67 | 21.46 | 11.33 | 21.68 | 9.83 | 21.11 |
May | 310.83 | 21.53 | 5.67 | 23.64 | 0.50 | 21.11 |
June | 220.50 | 22.42 | 41.83 | 23.94 | 0.00 | 0.00 |
July | 96.50 | 22.65 | 150.83 | 23.93 | 0.00 | 0.00 |
August | 42.17 | 23.24 | 195.50 | 23.92 | 0.00 | 0.00 |
September | 154.50 | 22.84 | 77.50 | 23.91 | 0.00 | 0.00 |
October | 339.17 | 21.46 | 1.67 | 21.11 | 1.67 | 21.11 |
November | 330.00 | 21.11 | 32.00 | 21.11 | 32.00 | 21.11 |
December | 338.00 | 21.11 | 126.50 | 21.11 | 126.50 | 21.11 |
Annual Sum or Average | 3136.33 | 21.48 | 873.50 | 22.63 | 401.17 | 21.11 |
Minimum of Months | 42.17 | 21.11 | 1.67 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.24 | 195.50 | 23.94 | 126.50 | 21.11 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 189.67 | 21.11 | 189.67 | 21.11 |
February | 308.00 | 21.11 | 151.33 | 21.11 | 151.33 | 21.11 |
March | 348.00 | 21.11 | 153.33 | 21.11 | 153.33 | 21.11 |
April | 311.50 | 21.37 | 31.00 | 21.21 | 30.33 | 21.11 |
May | 328.33 | 21.47 | 12.17 | 21.11 | 12.17 | 21.11 |
June | 258.67 | 22.09 | 24.83 | 23.88 | 0.50 | 21.11 |
July | 140.83 | 22.51 | 106.33 | 23.93 | 0.00 | 0.00 |
August | 69.33 | 23.00 | 139.00 | 23.92 | 0.00 | 0.00 |
September | 202.33 | 22.59 | 51.33 | 23.91 | 0.00 | 0.00 |
October | 340.00 | 21.33 | 13.50 | 21.11 | 13.50 | 21.11 |
November | 330.00 | 21.11 | 90.50 | 21.11 | 90.50 | 21.11 |
December | 338.00 | 21.11 | 252.33 | 21.11 | 252.33 | 21.11 |
Annual Sum or Average | 3315.00 | 21.46 | 1215.33 | 21.85 | 893.67 | 21.11 |
Minimum of Months | 69.33 | 21.11 | 12.17 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.00 | 252.33 | 23.93 | 252.33 | 21.11 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.09209 | 31.05539 | -0.4183 | 8.88677 |
February | 448.00000 | 21.07886 | 32.08078 | -0.4084 | 8.64261 |
March | 496.00000 | 21.12168 | 32.12438 | -0.3903 | 8.36365 |
April | 480.00000 | 22.19817 | 31.27430 | -0.0717 | 6.64177 |
May | 496.00000 | 22.45403 | 36.98723 | -0.9941 | 28.22856 |
June | 480.00000 | 23.65557 | 43.18445 | -0.5155 | 11.34190 |
July | 496.00000 | 23.83630 | 44.47631 | -0.4171 | 8.99342 |
August | 496.00000 | 23.88097 | 44.93090 | -0.3976 | 8.54444 |
September | 480.00000 | 23.79514 | 41.79840 | -0.4710 | 10.15425 |
October | 496.00000 | 22.22172 | 39.57793 | -0.0276 | 6.31892 |
November | 480.00000 | 21.17290 | 36.10731 | -0.3381 | 7.61381 |
December | 496.00000 | 21.07696 | 30.16102 | -0.4443 | 9.27116 |
Annual Sum or Average | 5840.00000 | 22.30427 | 37.00795 | -0.4085 | 10.27770 |
Minimum of Months | 448.00000 | 21.07696 | 30.16102 | -0.9941 | 6.31892 |
Maximum of Months | 496.00000 | 23.88097 | 44.93090 | -0.0276 | 28.22856 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.70601 | 31.68871 | -0.2589 | 7.12265 |
February | 448.00000 | 21.66976 | 32.65815 | -0.2542 | 6.90859 |
March | 496.00000 | 21.78841 | 32.37318 | -0.2232 | 6.75587 |
April | 480.00000 | 22.97142 | 30.57700 | 0.10399 | 6.33466 |
May | 496.00000 | 23.14792 | 35.88792 | -0.7715 | 19.14833 |
June | 480.00000 | 23.81957 | 42.67257 | -0.4454 | 9.49097 |
July | 496.00000 | 23.87493 | 44.18863 | -0.3901 | 8.37787 |
August | 496.00000 | 23.88635 | 44.78342 | -0.3786 | 8.16807 |
September | 480.00000 | 23.86451 | 41.54535 | -0.4311 | 9.16686 |
October | 496.00000 | 22.93489 | 38.55025 | 0.13228 | 6.37142 |
November | 480.00000 | 21.90595 | 35.88512 | -0.1678 | 6.36527 |
December | 496.00000 | 21.63127 | 30.73490 | -0.2955 | 7.40866 |
Annual Sum or Average | 5840.00000 | 22.77167 | 36.81985 | -0.2824 | 8.48798 |
Minimum of Months | 448.00000 | 21.63127 | 30.57700 | -0.7715 | 6.33466 |
Maximum of Months | 496.00000 | 23.88635 | 44.78342 | 0.13228 | 19.14833 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.12806 | 30.99600 | -0.3887 | 8.33637 |
February | 336.00000 | 21.11710 | 32.22958 | -0.3735 | 8.00922 |
March | 379.00000 | 21.16321 | 31.50799 | -0.3594 | 7.81999 |
April | 360.00000 | 22.42014 | 30.28607 | -0.0115 | 6.52275 |
May | 375.00000 | 22.66675 | 36.30979 | -0.9073 | 24.61087 |
June | 366.00000 | 23.79341 | 42.59217 | -0.4589 | 9.97087 |
July | 369.00000 | 23.92372 | 44.27120 | -0.3788 | 8.35017 |
August | 379.00000 | 23.95671 | 44.73213 | -0.3602 | 7.95030 |
September | 360.00000 | 23.85679 | 41.66753 | -0.4349 | 9.41293 |
October | 371.00000 | 22.33917 | 39.19775 | 0.00885 | 6.27441 |
November | 360.00000 | 21.21854 | 35.92504 | -0.3130 | 7.25199 |
December | 369.00000 | 21.11198 | 29.98411 | -0.4165 | 8.71803 |
Annual Sum or Average | 4395.00000 | 22.39979 | 36.67974 | -0.3673 | 9.46821 |
Minimum of Months | 336.00000 | 21.11198 | 29.98411 | -0.9073 | 6.27441 |
Maximum of Months | 379.00000 | 23.95671 | 44.73213 | 0.00885 | 24.61087 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.11911 | 31.02329 | -0.4034 | 8.57742 |
February | 336.00000 | 21.11332 | 32.24393 | -0.3860 | 8.21104 |
March | 379.00000 | 21.14623 | 31.54854 | -0.3739 | 8.03844 |
April | 360.00000 | 22.29681 | 30.50516 | -0.0473 | 6.59485 |
May | 375.00000 | 22.54116 | 36.57818 | -0.9565 | 26.68904 |
June | 366.00000 | 23.76350 | 42.67476 | -0.4748 | 10.36569 |
July | 369.00000 | 23.91312 | 44.31036 | -0.3867 | 8.51509 |
August | 379.00000 | 23.95404 | 44.75527 | -0.3644 | 8.01507 |
September | 360.00000 | 23.84521 | 41.71483 | -0.4441 | 9.61144 |
October | 371.00000 | 22.21891 | 39.49974 | -0.0265 | 6.31873 |
November | 360.00000 | 21.18568 | 36.00813 | -0.3320 | 7.48685 |
December | 369.00000 | 21.11063 | 29.99380 | -0.4293 | 8.94821 |
Annual Sum or Average | 4395.00000 | 22.35895 | 36.77663 | -0.3866 | 9.81692 |
Minimum of Months | 336.00000 | 21.11063 | 29.99380 | -0.9565 | 6.31873 |
Maximum of Months | 379.00000 | 23.95404 | 44.75527 | -0.0265 | 26.68904 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.11337 | 31.02851 | -0.4185 | 8.84329 |
February | 336.00000 | 21.11082 | 32.24301 | -0.3997 | 8.44144 |
March | 379.00000 | 21.13021 | 31.57338 | -0.3898 | 8.28955 |
April | 360.00000 | 22.12776 | 30.81603 | -0.0946 | 6.69242 |
May | 375.00000 | 22.36480 | 36.96228 | -1.0241 | 29.57298 |
June | 366.00000 | 23.68156 | 42.90136 | -0.5131 | 11.36782 |
July | 369.00000 | 23.88567 | 44.40804 | -0.4058 | 8.91607 |
August | 379.00000 | 23.94525 | 44.81096 | -0.3763 | 8.21175 |
September | 360.00000 | 23.81151 | 41.83473 | -0.4656 | 10.10191 |
October | 371.00000 | 22.05349 | 39.91465 | -0.0732 | 6.35617 |
November | 360.00000 | 21.15653 | 36.07555 | -0.3505 | 7.73387 |
December | 369.00000 | 21.10993 | 29.98800 | -0.4441 | 9.22635 |
Annual Sum or Average | 4395.00000 | 22.29894 | 36.91913 | -0.4142 | 10.35370 |
Minimum of Months | 336.00000 | 21.10993 | 29.98800 | -1.0241 | 6.35617 |
Maximum of Months | 379.00000 | 23.94525 | 44.81096 | -0.0732 | 29.57298 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10991 | 31.86337 | -0.4636 | 9.67111 |
February | 308.00000 | 21.10982 | 32.99970 | -0.4413 | 9.15644 |
March | 348.00000 | 21.11056 | 32.33387 | -0.4337 | 9.02276 |
April | 330.00000 | 21.78628 | 32.11224 | -0.1873 | 7.07942 |
May | 344.00000 | 21.99308 | 38.48880 | -1.1632 | 35.73573 |
June | 336.00000 | 23.35613 | 44.45807 | -0.6360 | 14.84577 |
July | 338.00000 | 23.75273 | 45.34769 | -0.4689 | 10.28900 |
August | 348.00000 | 23.89006 | 45.47464 | -0.4158 | 8.81882 |
September | 330.00000 | 23.68137 | 42.88440 | -0.5298 | 11.54961 |
October | 340.00000 | 21.69385 | 41.51774 | -0.1740 | 6.54667 |
November | 330.00000 | 21.11399 | 36.97255 | -0.3978 | 8.42850 |
December | 338.00000 | 21.10991 | 30.77060 | -0.4938 | 10.19223 |
Annual Sum or Average | 4030.00000 | 22.14991 | 37.97685 | -0.4852 | 11.83028 |
Minimum of Months | 308.00000 | 21.10982 | 30.77060 | -1.1632 | 6.54667 |
Maximum of Months | 348.00000 | 23.89006 | 45.47464 | -0.1740 | 35.73573 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10964 | 31.69593 | -0.4695 | 9.78229 |
February | 308.00000 | 21.10957 | 32.92203 | -0.4482 | 9.28192 |
March | 348.00000 | 21.11023 | 32.13174 | -0.4424 | 9.18325 |
April | 330.00000 | 21.71501 | 32.20240 | -0.2187 | 7.28664 |
May | 344.00000 | 21.88243 | 38.68695 | -1.2208 | 38.29241 |
June | 336.00000 | 23.17386 | 44.73889 | -0.7185 | 17.55503 |
July | 338.00000 | 23.65331 | 45.04333 | -0.5297 | 11.89628 |
August | 348.00000 | 23.84952 | 44.98022 | -0.4581 | 9.68925 |
September | 330.00000 | 23.55189 | 42.90958 | -0.5958 | 13.46118 |
October | 340.00000 | 21.60495 | 41.61557 | -0.2072 | 6.65329 |
November | 330.00000 | 21.11350 | 36.84227 | -0.4061 | 8.56581 |
December | 338.00000 | 21.10935 | 30.62812 | -0.4978 | 10.27367 |
Annual Sum or Average | 4030.00000 | 22.08933 | 37.90652 | -0.5193 | 12.71776 |
Minimum of Months | 308.00000 | 21.10935 | 30.62812 | -1.2208 | 6.65329 |
Maximum of Months | 348.00000 | 23.84952 | 45.04333 | -0.2072 | 38.29241 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10997 | 31.69500 | -0.4748 | 9.88709 |
February | 308.00000 | 21.10997 | 32.92123 | -0.4536 | 9.38440 |
March | 348.00000 | 21.11004 | 32.13175 | -0.4477 | 9.28361 |
April | 330.00000 | 21.67794 | 32.27286 | -0.2325 | 7.37716 |
May | 344.00000 | 21.82935 | 38.81293 | -1.2461 | 39.42023 |
June | 336.00000 | 23.07393 | 45.03834 | -0.7590 | 18.97062 |
July | 338.00000 | 23.60489 | 45.23141 | -0.5531 | 12.63158 |
August | 348.00000 | 23.83788 | 45.08015 | -0.4687 | 9.93140 |
September | 330.00000 | 23.48729 | 43.11391 | -0.6241 | 14.33594 |
October | 340.00000 | 21.55105 | 41.73413 | -0.2246 | 6.71621 |
November | 330.00000 | 21.11249 | 36.84541 | -0.4112 | 8.65265 |
December | 338.00000 | 21.10960 | 30.62785 | -0.5027 | 10.37813 |
Annual Sum or Average | 4030.00000 | 22.05850 | 37.99925 | -0.5348 | 13.14020 |
Minimum of Months | 308.00000 | 21.10960 | 30.62785 | -1.2461 | 6.71621 |
Maximum of Months | 348.00000 | 23.83788 | 45.23141 | -0.2246 | 39.42023 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10950 | 31.69507 | -0.4900 | 10.20266 |
February | 308.00000 | 21.10972 | 32.92134 | -0.4697 | 9.70085 |
March | 348.00000 | 21.10931 | 32.13258 | -0.4632 | 9.58327 |
April | 330.00000 | 21.61311 | 32.39688 | -0.2580 | 7.59087 |
May | 344.00000 | 21.73897 | 39.03213 | -1.2909 | 41.46735 |
June | 336.00000 | 22.88426 | 45.60567 | -0.8319 | 21.63864 |
July | 338.00000 | 23.51099 | 45.61367 | -0.5957 | 14.00569 |
August | 348.00000 | 23.80403 | 45.32675 | -0.4920 | 10.50827 |
September | 330.00000 | 23.35505 | 43.51922 | -0.6769 | 16.04740 |
October | 340.00000 | 21.46443 | 41.92674 | -0.2540 | 6.88777 |
November | 330.00000 | 21.11081 | 36.85073 | -0.4246 | 8.89268 |
December | 338.00000 | 21.10975 | 30.62737 | -0.5178 | 10.70538 |
Annual Sum or Average | 4030.00000 | 22.00049 | 38.17869 | -0.5654 | 13.99835 |
Minimum of Months | 308.00000 | 21.10931 | 30.62737 | -1.2909 | 6.88777 |
Maximum of Months | 348.00000 | 23.80403 | 45.61367 | -0.2540 | 41.46735 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10981 | 31.66656 | -0.5519 | 11.58636 |
February | 308.00000 | 21.10968 | 32.85654 | -0.5358 | 11.11502 |
March | 348.00000 | 21.10972 | 32.07065 | -0.5277 | 10.94734 |
April | 330.00000 | 21.51369 | 32.50925 | -0.3206 | 8.32109 |
May | 344.00000 | 21.57541 | 39.35018 | -1.4008 | 46.75054 |
June | 336.00000 | 22.48921 | 46.67416 | -0.9926 | 28.12479 |
July | 338.00000 | 23.29190 | 46.41265 | -0.6990 | 17.45225 |
August | 348.00000 | 23.68140 | 45.92293 | -0.5665 | 12.58177 |
September | 330.00000 | 23.06306 | 44.23539 | -0.7965 | 20.28224 |
October | 340.00000 | 21.32849 | 42.11613 | -0.3221 | 7.58747 |
November | 330.00000 | 21.10964 | 36.76577 | -0.4773 | 9.91772 |
December | 338.00000 | 21.10997 | 30.54427 | -0.5784 | 12.12213 |
Annual Sum or Average | 4030.00000 | 21.88108 | 38.47061 | -0.6492 | 16.46920 |
Minimum of Months | 308.00000 | 21.10964 | 30.54427 | -1.4008 | 7.58747 |
Maximum of Months | 348.00000 | 23.68140 | 46.67416 | -0.3206 | 46.75054 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.461656E+09 | 0.132395E+09 | 46.06 | 0.460275E+09 | 1381513.12 | 0.00 | 0.52 | 30-APR-16:05 | 0.00 | 01-APR-00:05 | 13375.51 | 30-APR-16:05 | 13375.51 | 30-APR-16:05 | 248.11 | 28-APR-15:00 | 3766.33 | 30-APR-16:05 | 0.00 | 01-APR-00:05 |
May | 0.255980E+09 | 74729525.75 | 60.25 | 0.227672E+09 | 28308718.27 | 0.00 | 0.46 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 12019.36 | 22-MAY-15:00 | 11200.50 | 22-MAY-15:00 | 939.38 | 22-MAY-14:00 | 3420.20 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.187834E+10 | 0.530765E+09 | 186.25 | 0.159843E+10 | 0.279910E+09 | 0.00 | 0.65 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 18066.28 | 13-JUN-17:00 | 16730.72 | 13-JUN-17:00 | 7518.46 | 25-JUN-18:00 | 5090.90 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.300006E+10 | 0.865748E+09 | 270.96 | 0.265074E+10 | 0.349322E+09 | 0.00 | 0.88 | 22-JUL-07:03 | 0.00 | 01-JUL-00:10 | 26569.93 | 22-JUL-07:03 | 24024.22 | 22-JUL-07:03 | 5304.26 | 23-JUL-07:03 | 6560.23 | 22-JUL-07:03 | 0.00 | 01-JUL-00:10 |
August | 0.264089E+10 | 0.761362E+09 | 310.18 | 0.225718E+10 | 0.383704E+09 | 0.00 | 0.62 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 16415.29 | 14-AUG-17:00 | 16415.29 | 14-AUG-17:00 | 2847.01 | 17-AUG-14:00 | 4738.39 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.168605E+10 | 0.481747E+09 | 230.27 | 0.145487E+10 | 0.231183E+09 | 0.00 | 0.50 | 13-SEP-14:00 | 0.00 | 01-SEP-00:10 | 13509.02 | 13-SEP-14:00 | 11677.53 | 13-SEP-14:00 | 3483.49 | 16-SEP-07:02 | 3731.94 | 13-SEP-14:00 | 0.00 | 01-SEP-00:10 |
October | 558849.92 | 170357.12 | 23.04 | 558025.00 | 824.92 | 0.00 | 0.03 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 618.31 | 07-OCT-15:00 | 618.31 | 07-OCT-15:00 | 0.11 | 08-OCT-18:20 | 188.16 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.992354E+10 | 0.284692E+10 | 1127.01 | 0.864973E+10 | 0.127381E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.300006E+10 | 0.865748E+09 | 310.18 | 0.265074E+10 | 0.383704E+09 | 0.00 | 0.88 | 0.00 | 26569.93 | 24024.22 | 7518.46 | 6560.23 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 24639.19 | 7301.09 | 0.50 | 24639.19 | 0.00 | 0.00 | 0.00 | 18-JAN-23:10 | 0.00 | 01-JAN-00:10 | 20.99 | 18-JAN-23:10 | 20.99 | 18-JAN-23:10 | 0.00 | 21-JAN-21:20 | 6.22 | 18-JAN-23:10 | 0.00 | 01-JAN-00:10 |
February | 12027.57 | 3552.48 | 0.17 | 12027.57 | 0.00 | 0.00 | 0.00 | 11-FEB-24:00 | 0.00 | 01-FEB-00:10 | 20.05 | 11-FEB-24:00 | 20.05 | 11-FEB-24:00 | 0.00 | 01-FEB-00:10 | 5.92 | 11-FEB-24:00 | 0.00 | 01-FEB-00:10 |
March | 293054.70 | 86742.66 | 0.83 | 268981.06 | 24073.64 | 0.00 | 0.01 | 25-MAR-23:20 | 0.00 | 01-MAR-00:10 | 167.04 | 25-MAR-23:20 | 158.90 | 25-MAR-23:20 | 16.60 | 18-MAR-23:10 | 49.42 | 25-MAR-23:20 | 0.00 | 01-MAR-00:10 |
April | 0.325813E+09 | 81861792.03 | 53.72 | 0.322738E+09 | 3075226.01 | 0.00 | 1.00 | 17-APR-20:01 | 0.00 | 01-APR-00:05 | 16666.44 | 30-APR-19:02 | 16666.44 | 30-APR-19:02 | 2140.59 | 30-APR-20:30 | 3541.45 | 30-APR-19:02 | 0.00 | 01-APR-00:05 |
May | 0.224710E+09 | 56967490.89 | 62.57 | 0.202100E+09 | 22610223.20 | 0.00 | 1.00 | 21-MAY-17:01 | 0.00 | 01-MAY-00:10 | 16692.82 | 21-MAY-18:52 | 16523.93 | 21-MAY-17:06 | 1646.62 | 21-MAY-19:30 | 3447.61 | 21-MAY-18:52 | 0.00 | 01-MAY-00:10 |
June | 0.116714E+10 | 0.291031E+09 | 173.18 | 0.993270E+09 | 0.173867E+09 | 0.00 | 1.00 | 06-JUN-21:12 | 0.00 | 01-JUN-00:10 | 18390.49 | 25-JUN-18:00 | 16363.85 | 06-JUN-21:12 | 7466.00 | 25-JUN-18:00 | 3783.71 | 25-JUN-18:00 | 0.00 | 01-JUN-00:10 |
July | 0.191468E+10 | 0.481280E+09 | 224.37 | 0.166909E+10 | 0.245597E+09 | 0.00 | 1.00 | 09-JUL-17:02 | 0.00 | 01-JUL-00:10 | 17683.10 | 23-JUL-17:02 | 16008.81 | 30-JUL-21:00 | 6895.49 | 25-JUL-07:01 | 3702.29 | 22-JUL-20:37 | 0.00 | 01-JUL-00:10 |
August | 0.179920E+10 | 0.455667E+09 | 264.16 | 0.152594E+10 | 0.273264E+09 | 0.00 | 1.00 | 06-AUG-17:01 | 0.00 | 01-AUG-00:10 | 17185.14 | 13-AUG-17:02 | 16440.34 | 14-AUG-20:06 | 5059.02 | 06-AUG-07:02 | 3553.97 | 13-AUG-17:02 | 0.00 | 01-AUG-00:10 |
September | 0.109527E+10 | 0.276447E+09 | 186.40 | 0.942234E+09 | 0.153039E+09 | 0.00 | 1.00 | 02-SEP-23:36 | 0.00 | 01-SEP-00:10 | 17567.25 | 10-SEP-17:02 | 16391.96 | 27-SEP-22:12 | 6362.66 | 16-SEP-07:02 | 3626.66 | 10-SEP-17:02 | 0.00 | 01-SEP-00:10 |
October | 14965321.12 | 3995027.34 | 45.55 | 14505511.33 | 459809.79 | 0.00 | 1.00 | 03-OCT-20:01 | 0.00 | 01-OCT-00:10 | 16333.39 | 04-OCT-20:01 | 16333.39 | 04-OCT-20:01 | 269.04 | 17-OCT-20:10 | 3361.71 | 04-OCT-20:01 | 0.00 | 01-OCT-00:10 |
November | 711362.14 | 210299.19 | 2.33 | 653610.13 | 57752.01 | 0.00 | 0.03 | 08-NOV-23:40 | 0.00 | 01-NOV-00:10 | 339.47 | 08-NOV-23:40 | 290.86 | 08-NOV-23:40 | 48.61 | 08-NOV-23:40 | 100.07 | 08-NOV-23:40 | 0.00 | 01-NOV-00:10 |
December | 23541.82 | 6979.10 | 0.50 | 23541.82 | 0.00 | 0.00 | 0.00 | 24-DEC-23:00 | 0.00 | 01-DEC-00:05 | 18.15 | 24-DEC-23:00 | 18.15 | 24-DEC-23:00 | 0.00 | 01-DEC-00:05 | 5.37 | 24-DEC-23:00 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.654285E+10 | 0.164756E+10 | 1014.29 | 0.567085E+10 | 0.871994E+09 | 0.00 | ||||||||||||||
Minimum of Months | 12027.57 | 3552.48 | 0.17 | 12027.57 | 0.00 | 0.00 | 0.00 | 0.00 | 18.15 | 18.15 | 0.00 | 5.37 | 0.00 | |||||||
Maximum of Months | 0.191468E+10 | 0.481280E+09 | 264.16 | 0.166909E+10 | 0.273264E+09 | 0.00 | 1.00 | 0.00 | 18390.49 | 16666.44 | 7466.00 | 3783.71 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.160576E+09 | 41462545.05 | 39.43 | 0.159808E+09 | 767274.14 | 0.00 | 0.50 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 7135.48 | 30-APR-15:00 | 7135.48 | 30-APR-15:00 | 153.11 | 28-APR-15:00 | 1807.35 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.131484E+09 | 34344252.60 | 47.36 | 0.116325E+09 | 15159236.28 | 0.00 | 0.45 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 6515.30 | 22-MAY-15:00 | 6084.97 | 22-MAY-15:00 | 504.31 | 22-MAY-14:00 | 1663.56 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.926944E+09 | 0.235411E+09 | 158.35 | 0.798808E+09 | 0.128136E+09 | 0.00 | 0.70 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 | 11027.11 | 27-JUN-06:02 | 8842.78 | 13-JUN-17:00 | 4947.61 | 27-JUN-06:02 | 2509.07 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.136231E+10 | 0.351971E+09 | 208.59 | 0.120916E+10 | 0.153150E+09 | 0.00 | 1.00 | 18-JUL-06:02 | 0.00 | 01-JUL-00:10 | 17247.23 | 18-JUL-06:02 | 13637.37 | 23-JUL-07:03 | 6402.05 | 24-JUL-06:02 | 3566.44 | 18-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.141450E+10 | 0.365145E+09 | 243.73 | 0.120351E+10 | 0.210986E+09 | 0.00 | 0.65 | 06-AUG-07:02 | 0.00 | 01-AUG-00:10 | 9763.26 | 06-AUG-07:02 | 8635.57 | 14-AUG-17:00 | 3505.85 | 17-AUG-06:02 | 2250.17 | 06-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.883796E+09 | 0.226375E+09 | 170.34 | 0.769210E+09 | 0.114585E+09 | 0.00 | 0.70 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 | 10618.10 | 02-SEP-06:02 | 6884.14 | 02-SEP-06:02 | 3953.68 | 16-SEP-06:02 | 2412.66 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 1029368.85 | 280325.41 | 31.00 | 1029216.55 | 152.30 | 0.00 | 0.05 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 605.51 | 07-OCT-15:00 | 605.51 | 07-OCT-15:00 | 0.17 | 11-OCT-18:10 | 163.97 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.488063E+10 | 0.125499E+10 | 898.80 | 0.425785E+10 | 0.622783E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.141450E+10 | 0.365145E+09 | 243.73 | 0.120916E+10 | 0.210986E+09 | 0.00 | 1.00 | 0.00 | 17247.23 | 13637.37 | 6402.05 | 3566.44 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.152638E+09 | 39465283.50 | 34.93 | 0.151952E+09 | 686034.40 | 0.00 | 0.49 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 7037.49 | 30-APR-15:00 | 7037.49 | 30-APR-15:00 | 141.26 | 28-APR-15:00 | 1786.29 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.114725E+09 | 30057582.67 | 44.83 | 0.102002E+09 | 12723760.43 | 0.00 | 0.43 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 6226.15 | 22-MAY-15:00 | 5811.61 | 22-MAY-15:00 | 478.29 | 22-MAY-14:20 | 1598.16 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.902480E+09 | 0.229560E+09 | 153.48 | 0.777898E+09 | 0.124582E+09 | 0.00 | 0.62 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 | 9607.58 | 27-JUN-06:02 | 8773.07 | 13-JUN-17:00 | 4316.28 | 27-JUN-06:02 | 2412.21 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.132996E+10 | 0.343925E+09 | 204.68 | 0.118220E+10 | 0.147767E+09 | 0.00 | 1.00 | 23-JUL-07:03 | 0.00 | 01-JUL-00:10 | 17130.88 | 23-JUL-07:03 | 13684.00 | 23-JUL-07:03 | 6440.62 | 24-JUL-06:02 | 3542.93 | 23-JUL-07:03 | 0.00 | 01-JUL-00:10 |
August | 0.137078E+10 | 0.354215E+09 | 240.57 | 0.116758E+10 | 0.203206E+09 | 0.00 | 0.58 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 8569.34 | 14-AUG-17:00 | 8569.34 | 14-AUG-17:00 | 3079.17 | 17-AUG-06:02 | 2235.24 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.851024E+09 | 0.218295E+09 | 167.89 | 0.741558E+09 | 0.109466E+09 | 0.00 | 0.57 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 | 8399.06 | 02-SEP-06:02 | 6401.25 | 13-SEP-14:00 | 3058.97 | 16-SEP-06:02 | 1981.65 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 453300.48 | 123487.54 | 26.08 | 453283.98 | 16.50 | 0.00 | 0.04 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 434.74 | 07-OCT-15:00 | 434.74 | 07-OCT-15:00 | 0.01 | 04-OCT-17:10 | 118.14 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.472207E+10 | 0.121564E+10 | 872.46 | 0.412364E+10 | 0.598430E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.137078E+10 | 0.354215E+09 | 240.57 | 0.118220E+10 | 0.203206E+09 | 0.00 | 1.00 | 0.00 | 17130.88 | 13684.00 | 6440.62 | 3542.93 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.138570E+09 | 35912332.78 | 32.85 | 0.138026E+09 | 544244.18 | 0.00 | 0.48 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 6802.57 | 30-APR-15:00 | 6802.57 | 30-APR-15:00 | 118.04 | 28-APR-15:00 | 1731.99 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 92831955.98 | 24398196.27 | 43.83 | 83252027.74 | 9579928.24 | 0.00 | 0.40 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 5803.32 | 22-MAY-15:00 | 5412.86 | 22-MAY-15:00 | 441.73 | 22-MAY-14:20 | 1499.18 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.848267E+09 | 0.216279E+09 | 138.62 | 0.731644E+09 | 0.116624E+09 | 0.00 | 0.61 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 9279.04 | 13-JUN-16:30 | 8570.43 | 13-JUN-17:00 | 2308.94 | 27-JUN-06:02 | 2363.10 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.124771E+10 | 0.323327E+09 | 198.13 | 0.111314E+10 | 0.134569E+09 | 0.00 | 1.00 | 23-JUL-07:03 | 0.00 | 01-JUL-00:10 | 16978.38 | 23-JUL-07:03 | 13540.04 | 23-JUL-07:03 | 4773.05 | 24-JUL-06:02 | 3511.38 | 23-JUL-07:03 | 0.00 | 01-JUL-00:10 |
August | 0.126578E+10 | 0.327562E+09 | 236.66 | 0.108159E+10 | 0.184185E+09 | 0.00 | 0.57 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 8393.61 | 14-AUG-17:00 | 8393.61 | 14-AUG-17:00 | 1522.84 | 17-AUG-14:00 | 2193.30 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.783993E+09 | 0.201522E+09 | 159.96 | 0.684709E+09 | 99284547.07 | 0.00 | 0.48 | 13-SEP-14:00 | 0.00 | 01-SEP-00:10 | 7174.97 | 13-SEP-14:00 | 6214.01 | 13-SEP-14:00 | 1399.85 | 12-SEP-14:00 | 1782.31 | 13-SEP-14:00 | 0.00 | 01-SEP-00:10 |
October | 166954.86 | 45730.53 | 15.25 | 166953.72 | 1.14 | 0.00 | 0.01 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 129.26 | 07-OCT-15:00 | 129.26 | 07-OCT-15:00 | 0.00 | 04-OCT-17:10 | 35.34 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.437732E+10 | 0.112905E+10 | 825.31 | 0.383253E+10 | 0.544786E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.126578E+10 | 0.327562E+09 | 236.66 | 0.111314E+10 | 0.184185E+09 | 0.00 | 1.00 | 0.00 | 16978.38 | 13540.04 | 4773.05 | 3511.38 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.189388E+09 | 55113244.12 | 24.42 | 0.188830E+09 | 557826.73 | 0.00 | 0.46 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 11419.65 | 30-APR-15:00 | 11419.65 | 30-APR-15:00 | 143.57 | 28-APR-15:00 | 3266.78 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.106768E+09 | 31487398.51 | 28.67 | 97369164.50 | 9398473.54 | 0.00 | 0.37 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 9292.95 | 22-MAY-15:00 | 8571.63 | 22-MAY-15:00 | 722.51 | 22-MAY-14:30 | 2706.28 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.129839E+10 | 0.372414E+09 | 92.84 | 0.111701E+10 | 0.181387E+09 | 0.00 | 0.59 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 15768.31 | 13-JUN-16:20 | 14419.59 | 13-JUN-17:00 | 2983.73 | 26-JUN-16:20 | 4502.21 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.185911E+10 | 0.540656E+09 | 172.63 | 0.167057E+10 | 0.188538E+09 | 0.00 | 0.79 | 22-JUL-07:03 | 0.00 | 01-JUL-00:10 | 22356.87 | 22-JUL-07:03 | 19972.39 | 22-JUL-07:03 | 6662.71 | 24-JUL-07:02 | 5686.50 | 22-JUL-07:03 | 0.00 | 01-JUL-00:10 |
August | 0.182073E+10 | 0.528337E+09 | 217.40 | 0.156688E+10 | 0.253857E+09 | 0.00 | 0.56 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 14230.02 | 14-AUG-17:00 | 14230.02 | 14-AUG-17:00 | 2574.98 | 17-AUG-14:10 | 4174.31 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.112063E+10 | 0.323592E+09 | 121.75 | 0.980462E+09 | 0.140172E+09 | 0.00 | 0.47 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 | 12078.17 | 13-SEP-14:10 | 10420.75 | 13-SEP-14:10 | 2215.14 | 12-SEP-14:10 | 3369.70 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 |
October | 11819.80 | 3623.82 | 4.83 | 11819.80 | 0.00 | 0.00 | 0.00 | 07-OCT-13:00 | 0.00 | 01-OCT-00:10 | 2.43 | 07-OCT-13:00 | 2.43 | 07-OCT-13:00 | 0.00 | 07-OCT-15:30 | 0.75 | 07-OCT-13:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.639504E+10 | 0.185160E+10 | 662.53 | 0.562113E+10 | 0.773911E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.185911E+10 | 0.540656E+09 | 217.40 | 0.167057E+10 | 0.253857E+09 | 0.00 | 0.79 | 0.00 | 22356.87 | 19972.39 | 6662.71 | 5686.50 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.234445E+09 | 61137982.87 | 31.33 | 0.234429E+09 | 16174.36 | 0.00 | 0.45 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 5819.63 | 30-APR-15:00 | 5819.63 | 30-APR-15:00 | 5.37 | 28-APR-11:00 | 1492.80 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.214090E+09 | 56523992.90 | 34.83 | 0.191533E+09 | 22557350.82 | 0.00 | 0.36 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4657.99 | 22-MAY-15:00 | 4310.42 | 22-MAY-15:00 | 439.56 | 23-MAY-17:10 | 1217.48 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.113675E+10 | 0.292964E+09 | 118.56 | 0.100636E+10 | 0.130388E+09 | 0.00 | 0.59 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 8097.51 | 13-JUN-16:30 | 7419.04 | 13-JUN-17:00 | 1514.99 | 26-JUN-17:10 | 2074.15 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.241665E+10 | 0.625788E+09 | 239.94 | 0.213201E+10 | 0.284636E+09 | 0.00 | 0.79 | 24-JUL-07:02 | 0.00 | 01-JUL-00:10 | 11851.58 | 24-JUL-07:02 | 10268.61 | 23-JUL-08:63 | 2743.38 | 24-JUL-07:02 | 2613.55 | 24-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.304975E+10 | 0.787109E+09 | 307.58 | 0.267561E+10 | 0.374139E+09 | 0.00 | 0.56 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 7367.56 | 14-AUG-17:00 | 7367.56 | 14-AUG-17:00 | 1171.05 | 17-AUG-14:10 | 1934.44 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.147103E+10 | 0.378907E+09 | 172.69 | 0.131375E+10 | 0.157280E+09 | 0.00 | 0.48 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 | 6489.69 | 13-SEP-14:20 | 5765.53 | 13-SEP-14:20 | 1097.42 | 12-SEP-14:10 | 1613.03 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 |
October | 14168050.13 | 3775696.92 | 4.00 | 14168050.13 | 0.00 | 0.00 | 0.16 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1928.38 | 07-OCT-15:00 | 1928.38 | 07-OCT-15:00 | 0.00 | 07-OCT-15:20 | 506.95 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.853687E+10 | 0.220621E+10 | 908.93 | 0.756786E+10 | 0.969017E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.304975E+10 | 0.787109E+09 | 307.58 | 0.267561E+10 | 0.374139E+09 | 0.00 | 0.79 | 0.00 | 11851.58 | 10268.61 | 2743.38 | 2613.55 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.213769E+09 | 55824353.46 | 29.50 | 0.213757E+09 | 11545.52 | 0.00 | 0.45 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 5663.68 | 30-APR-15:00 | 5663.68 | 30-APR-15:00 | 4.22 | 28-APR-11:00 | 1455.91 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.189464E+09 | 50115021.81 | 31.67 | 0.169265E+09 | 20198693.87 | 0.00 | 0.35 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4485.64 | 22-MAY-15:00 | 4148.59 | 22-MAY-15:00 | 420.40 | 23-MAY-17:10 | 1175.50 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.104564E+10 | 0.269766E+09 | 106.09 | 0.924138E+09 | 0.121507E+09 | 0.00 | 0.58 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 7937.98 | 13-JUN-16:30 | 7273.69 | 13-JUN-17:00 | 1483.81 | 26-JUN-17:10 | 2037.57 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.227355E+10 | 0.589465E+09 | 231.09 | 0.200510E+10 | 0.268449E+09 | 0.00 | 0.71 | 23-JUL-08:63 | 0.00 | 01-JUL-00:10 | 10152.15 | 23-JUL-08:63 | 9528.40 | 23-JUL-08:63 | 2313.76 | 24-JUL-07:02 | 2398.75 | 22-JUL-15:00 | 0.00 | 01-JUL-00:10 |
August | 0.289211E+10 | 0.747459E+09 | 302.91 | 0.253542E+10 | 0.356690E+09 | 0.00 | 0.55 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 7249.38 | 14-AUG-17:00 | 7249.38 | 14-AUG-17:00 | 1154.81 | 17-AUG-14:10 | 1905.56 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.135636E+10 | 0.349707E+09 | 158.33 | 0.120986E+10 | 0.146496E+09 | 0.00 | 0.48 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 | 6354.13 | 13-SEP-14:20 | 5640.80 | 13-SEP-14:20 | 1072.00 | 12-SEP-14:10 | 1581.77 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 |
October | 10931650.79 | 2921205.82 | 3.33 | 10931650.79 | 0.00 | 0.00 | 0.15 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1702.17 | 07-OCT-15:00 | 1702.17 | 07-OCT-15:00 | 0.00 | 07-OCT-13:20 | 449.52 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.798183E+10 | 0.206526E+10 | 862.92 | 0.706848E+10 | 0.913352E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.289211E+10 | 0.747459E+09 | 302.91 | 0.253542E+10 | 0.356690E+09 | 0.00 | 0.71 | 0.00 | 10152.15 | 9528.40 | 2313.76 | 2398.75 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.179487E+09 | 46994474.55 | 26.83 | 0.179481E+09 | 5882.91 | 0.00 | 0.43 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 5358.71 | 30-APR-15:00 | 5358.71 | 30-APR-15:00 | 2.66 | 28-APR-15:20 | 1383.57 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 0.148001E+09 | 39283863.16 | 27.00 | 0.131988E+09 | 16013255.97 | 0.00 | 0.33 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4154.82 | 22-MAY-15:00 | 3838.40 | 22-MAY-15:00 | 381.49 | 23-MAY-17:10 | 1094.46 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.898561E+09 | 0.232401E+09 | 89.50 | 0.791533E+09 | 0.107028E+09 | 0.00 | 0.57 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 7644.54 | 13-JUN-16:30 | 7005.05 | 13-JUN-17:00 | 1415.13 | 26-JUN-17:10 | 1969.66 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.199178E+10 | 0.517760E+09 | 212.71 | 0.175740E+10 | 0.234381E+09 | 0.00 | 0.67 | 22-JUL-15:00 | 0.00 | 01-JUL-00:10 | 8985.43 | 22-JUL-15:00 | 8985.43 | 22-JUL-15:00 | 1112.33 | 24-JUL-17:10 | 2354.82 | 22-JUL-15:00 | 0.00 | 01-JUL-00:10 |
August | 0.254901E+10 | 0.660769E+09 | 290.17 | 0.223186E+10 | 0.317149E+09 | 0.00 | 0.54 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 7002.93 | 14-AUG-17:00 | 7002.93 | 14-AUG-17:00 | 1121.11 | 17-AUG-14:10 | 1845.67 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.116788E+10 | 0.301724E+09 | 134.67 | 0.103975E+10 | 0.128125E+09 | 0.00 | 0.47 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 | 6108.80 | 13-SEP-14:20 | 5415.49 | 13-SEP-14:20 | 1029.75 | 12-SEP-14:10 | 1524.96 | 13-SEP-14:20 | 0.00 | 01-SEP-00:10 |
October | 6750578.09 | 1811322.36 | 2.50 | 6750578.09 | 0.00 | 0.00 | 0.12 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1349.39 | 07-OCT-15:00 | 1349.39 | 07-OCT-15:00 | 0.00 | 07-OCT-14:40 | 358.92 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.694146E+10 | 0.180074E+10 | 783.37 | 0.613876E+10 | 0.802703E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.254901E+10 | 0.660769E+09 | 290.17 | 0.223186E+10 | 0.317149E+09 | 0.00 | 0.67 | 0.00 | 8985.43 | 8985.43 | 1415.13 | 2354.82 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.133653E+09 | 35151736.07 | 20.00 | 0.133650E+09 | 3190.74 | 0.00 | 0.40 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 4792.59 | 30-APR-15:00 | 4792.59 | 30-APR-15:00 | 3.05 | 28-APR-15:20 | 1249.03 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 97573146.50 | 26068467.19 | 18.83 | 87207488.84 | 10365657.66 | 0.00 | 0.30 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 3605.81 | 22-MAY-15:00 | 3325.51 | 22-MAY-15:00 | 287.24 | 23-MAY-17:10 | 958.80 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.710206E+09 | 0.184554E+09 | 72.83 | 0.623129E+09 | 87076694.79 | 0.00 | 0.55 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 7137.65 | 13-JUN-16:30 | 6528.67 | 13-JUN-17:00 | 1229.66 | 26-JUN-17:10 | 1850.30 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
July | 0.148820E+10 | 0.388490E+09 | 174.65 | 0.132262E+10 | 0.165576E+09 | 0.00 | 0.67 | 22-JUL-15:00 | 0.00 | 01-JUL-00:10 | 8756.74 | 22-JUL-15:00 | 8756.74 | 22-JUL-15:00 | 965.11 | 24-JUL-17:10 | 2296.65 | 22-JUL-15:00 | 0.00 | 01-JUL-00:10 |
August | 0.187743E+10 | 0.489597E+09 | 252.83 | 0.164189E+10 | 0.235543E+09 | 0.00 | 0.52 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 | 6513.68 | 14-AUG-17:00 | 6513.68 | 14-AUG-17:00 | 1047.61 | 17-AUG-14:10 | 1728.56 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
September | 0.896611E+09 | 0.232621E+09 | 110.33 | 0.797297E+09 | 99313696.62 | 0.00 | 0.44 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 | 5665.72 | 13-SEP-14:10 | 5013.27 | 13-SEP-14:10 | 958.56 | 12-SEP-14:10 | 1423.00 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 |
October | 2205036.39 | 597539.01 | 1.50 | 2205036.39 | 0.00 | 0.00 | 0.07 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 717.35 | 07-OCT-15:00 | 717.35 | 07-OCT-15:00 | 0.00 | 07-OCT-15:40 | 193.43 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.520588E+10 | 0.135708E+10 | 650.99 | 0.460800E+10 | 0.597878E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.187743E+10 | 0.489597E+09 | 252.83 | 0.164189E+10 | 0.235543E+09 | 0.00 | 0.67 | 0.00 | 8756.74 | 8756.74 | 1229.66 | 2296.65 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.38 | 86.19 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.40 | 83.92 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.83 | 71.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.97 | 61.02 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.28 | 54.72 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.95 | 44.53 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.86 | 41.47 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.67 | 44.61 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.60 | 56.78 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.32 | 70.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.41 | 80.57 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.13 | 97.94 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.79 | 66.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.83 | 41.47 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.60 | 97.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.38 | 86.19 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.40 | 83.92 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.83 | 71.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.97 | 61.02 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.28 | 54.72 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.95 | 44.53 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.86 | 41.47 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.67 | 44.61 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.60 | 56.78 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.32 | 70.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.41 | 80.57 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.13 | 97.94 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.79 | 66.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.83 | 41.47 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.60 | 97.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.38 | 86.19 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.40 | 83.92 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.83 | 71.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.97 | 61.02 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.28 | 54.72 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.95 | 44.53 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.86 | 41.47 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.67 | 44.61 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.60 | 56.78 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.32 | 70.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.41 | 80.57 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.13 | 97.94 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.79 | 66.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.83 | 41.47 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.60 | 97.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.38 | 86.19 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.40 | 83.92 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.83 | 71.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.97 | 61.02 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.28 | 54.72 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.95 | 44.53 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.86 | 41.47 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.67 | 44.61 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.60 | 56.78 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.32 | 70.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.41 | 80.57 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.13 | 97.94 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.79 | 66.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.83 | 41.47 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.60 | 97.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 86.01 | 102.91 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 104.11 | 100.11 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 45.68 | 84.89 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 128.87 | 72.88 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 83.59 | 65.25 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 75.94 | 53.14 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 91.42 | 49.52 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 128.43 | 53.31 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 168.04 | 67.84 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 111.16 | 84.46 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 75.20 | 96.17 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 58.01 | 116.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 96.14 | 78.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 45.68 | 49.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 168.04 | 116.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 86.01 | 102.91 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 104.11 | 100.11 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 45.68 | 84.89 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 128.87 | 72.88 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 83.59 | 65.25 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 75.94 | 53.14 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 91.42 | 49.52 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 128.43 | 53.31 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 168.04 | 67.84 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 111.16 | 84.46 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 75.20 | 96.17 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 58.01 | 116.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 96.14 | 78.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 45.68 | 49.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 168.04 | 116.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 70.54 | 91.16 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.43 | 89.05 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 36.81 | 76.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 105.04 | 65.29 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 67.33 | 58.80 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 61.83 | 46.31 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.20 | 42.74 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.15 | 45.77 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 138.91 | 58.28 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.09 | 75.15 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 61.59 | 85.91 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.54 | 103.38 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 78.76 | 69.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 36.81 | 42.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 138.91 | 103.38 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 70.54 | 91.16 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.43 | 89.05 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 36.81 | 76.10 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 105.04 | 65.29 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 67.33 | 58.80 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 61.83 | 46.31 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.20 | 42.74 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.15 | 45.77 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 138.91 | 58.28 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.09 | 75.15 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 61.59 | 85.91 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.54 | 103.38 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 78.76 | 69.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 36.81 | 42.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 138.91 | 103.38 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 84.99 | 108.81 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 102.95 | 106.18 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 44.45 | 90.82 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 126.56 | 77.95 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 81.25 | 70.08 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 74.59 | 55.25 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 90.62 | 51.02 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 127.81 | 54.69 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 167.22 | 69.61 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 109.70 | 89.69 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 74.21 | 102.49 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 57.31 | 123.24 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 94.91 | 83.21 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 44.45 | 51.02 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 167.22 | 123.24 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 70.91 | 87.78 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.79 | 85.78 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.17 | 73.07 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 105.71 | 63.45 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 67.98 | 57.18 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.00 | 46.59 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.21 | 43.43 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.14 | 46.65 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.03 | 58.65 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.62 | 72.62 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 61.98 | 82.26 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.80 | 99.74 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.08 | 68.01 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.17 | 43.43 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.03 | 99.74 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 70.91 | 87.78 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.79 | 85.78 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.17 | 73.07 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 105.71 | 63.45 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 67.98 | 57.18 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.00 | 46.59 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.21 | 43.43 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.14 | 46.65 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.03 | 58.65 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.62 | 72.62 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 61.98 | 82.26 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.80 | 99.74 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.08 | 68.01 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.17 | 43.43 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.03 | 99.74 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 84.98 | 104.20 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 102.83 | 101.73 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 44.65 | 86.73 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 126.66 | 75.33 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 81.58 | 67.76 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 74.38 | 55.24 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 90.14 | 51.52 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 127.10 | 55.40 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 166.45 | 69.63 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 109.73 | 86.19 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 74.27 | 97.60 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 57.31 | 118.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 94.77 | 80.70 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 44.65 | 51.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 166.45 | 118.26 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.09 | 86.49 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.97 | 84.59 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.36 | 71.92 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.18 | 62.20 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 68.47 | 56.00 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.20 | 46.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.33 | 43.09 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.20 | 46.40 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.14 | 58.21 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.95 | 71.15 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.15 | 80.88 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.92 | 98.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.30 | 67.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.36 | 43.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.14 | 98.42 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.09 | 86.49 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 85.97 | 84.59 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.36 | 71.92 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.18 | 62.20 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 68.47 | 56.00 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.20 | 46.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.33 | 43.09 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.20 | 46.40 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.14 | 58.21 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 91.95 | 71.15 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.15 | 80.88 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 47.92 | 98.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.30 | 67.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.36 | 43.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.14 | 98.42 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 85.19 | 102.66 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 103.04 | 100.31 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 44.87 | 85.36 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 127.23 | 73.84 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 82.17 | 66.37 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 74.63 | 54.64 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 90.28 | 51.11 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 127.17 | 55.10 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 166.58 | 69.11 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 110.13 | 84.45 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 74.48 | 95.96 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 57.45 | 116.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 95.04 | 79.53 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 44.87 | 51.11 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 166.58 | 116.68 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.26 | 85.56 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.15 | 83.73 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.56 | 71.07 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.81 | 60.97 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.13 | 54.77 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.66 | 45.29 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.60 | 42.52 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.37 | 45.94 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.38 | 57.57 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.40 | 69.69 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.32 | 79.89 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.05 | 97.39 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.61 | 66.11 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.56 | 42.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.38 | 97.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.26 | 85.56 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.15 | 83.73 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 37.56 | 71.07 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 106.81 | 60.97 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 69.13 | 54.77 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 62.66 | 45.29 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 75.60 | 42.52 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.37 | 45.94 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 139.38 | 57.57 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 92.40 | 69.69 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.32 | 79.89 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.05 | 97.39 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 79.61 | 66.11 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 37.56 | 42.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 139.38 | 97.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 85.41 | 101.55 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 103.26 | 99.29 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 45.12 | 84.35 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 127.99 | 72.38 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 82.96 | 64.90 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 75.18 | 53.71 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 90.62 | 50.44 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 127.38 | 54.56 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 166.87 | 68.35 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 110.67 | 82.72 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 74.68 | 94.78 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 57.61 | 115.46 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 95.41 | 78.44 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 45.12 | 50.44 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 166.87 | 115.46 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.88 | 82.93 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.86 | 81.14 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.22 | 68.76 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.08 | 58.34 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.47 | 52.04 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 63.90 | 43.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.29 | 40.83 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.78 | 44.48 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.08 | 55.70 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.46 | 66.57 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.85 | 77.33 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.53 | 94.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.42 | 63.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.22 | 40.83 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.08 | 94.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.88 | 82.93 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.86 | 81.14 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.22 | 68.76 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.08 | 58.34 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.47 | 52.04 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 63.90 | 43.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.29 | 40.83 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.78 | 44.48 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.08 | 55.70 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.46 | 66.57 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.85 | 77.33 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.53 | 94.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.42 | 63.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.22 | 40.83 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.08 | 94.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.88 | 82.93 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.86 | 81.14 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.22 | 68.76 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.08 | 58.34 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.47 | 52.04 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 63.90 | 43.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.29 | 40.83 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.78 | 44.48 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.08 | 55.70 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.46 | 66.57 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.85 | 77.33 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.53 | 94.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.42 | 63.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.22 | 40.83 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.08 | 94.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.88 | 82.93 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.86 | 81.14 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.22 | 68.76 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.08 | 58.34 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.47 | 52.04 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 63.90 | 43.08 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.29 | 40.83 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 106.78 | 44.48 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.08 | 55.70 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.46 | 66.57 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.85 | 77.33 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.53 | 94.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.42 | 63.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.22 | 40.83 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.08 | 94.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 86.15 | 98.42 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 104.12 | 96.22 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 45.91 | 81.60 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 129.51 | 69.27 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 84.56 | 61.69 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 76.67 | 51.10 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 91.44 | 48.45 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 127.87 | 52.83 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 167.71 | 66.14 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 111.93 | 79.02 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 75.32 | 91.73 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.19 | 111.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 96.38 | 75.56 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 45.91 | 48.45 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 167.71 | 111.51 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 86.15 | 98.42 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 104.12 | 96.22 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 45.91 | 81.60 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 129.51 | 69.27 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 84.56 | 61.69 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 76.67 | 51.10 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 91.44 | 48.45 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 127.87 | 52.83 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 167.71 | 66.14 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 111.93 | 79.02 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 75.32 | 91.73 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.19 | 111.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 96.38 | 75.56 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 45.91 | 48.45 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 167.71 | 111.51 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.74 | 83.01 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.70 | 81.27 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.10 | 68.73 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.29 | 57.89 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.86 | 51.55 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 64.63 | 42.44 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.81 | 40.35 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.04 | 44.15 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.50 | 55.12 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.63 | 66.05 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.74 | 77.39 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.41 | 94.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.59 | 63.44 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.10 | 40.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.50 | 94.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.74 | 83.01 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.70 | 81.27 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.10 | 68.73 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.29 | 57.89 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 70.86 | 51.55 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 64.63 | 42.44 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 76.81 | 40.35 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.04 | 44.15 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.50 | 55.12 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.63 | 66.05 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.74 | 77.39 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.41 | 94.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.59 | 63.44 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.10 | 40.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.50 | 94.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 86.00 | 98.50 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 103.94 | 96.36 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 45.78 | 81.56 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 129.77 | 68.73 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 85.04 | 61.09 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 77.54 | 50.32 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 92.07 | 47.87 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 128.20 | 52.43 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 168.22 | 65.44 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 112.14 | 78.38 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 75.20 | 91.79 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.06 | 111.90 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 96.60 | 75.26 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 45.78 | 47.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 168.22 | 111.90 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.81 | 82.68 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.78 | 80.94 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.18 | 68.42 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.50 | 57.46 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.15 | 51.02 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.11 | 41.80 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 77.13 | 39.91 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.21 | 43.87 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.79 | 54.58 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.83 | 65.49 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.80 | 77.07 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.46 | 94.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.79 | 63.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.18 | 39.91 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.79 | 94.07 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 71.81 | 82.68 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 86.78 | 80.94 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.18 | 68.42 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.50 | 57.46 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.15 | 51.02 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.11 | 41.80 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 77.13 | 39.91 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.21 | 43.87 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.79 | 54.58 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.83 | 65.49 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.80 | 77.07 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.46 | 94.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 80.79 | 63.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.18 | 39.91 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.79 | 94.07 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 86.08 | 98.10 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 104.03 | 95.95 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 45.88 | 81.18 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 130.02 | 68.21 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 85.39 | 60.47 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 78.11 | 49.57 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 92.46 | 47.34 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 128.40 | 52.10 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 168.57 | 64.80 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 112.38 | 77.71 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 75.27 | 91.41 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.12 | 111.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 96.83 | 74.76 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 45.88 | 47.34 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 168.57 | 111.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 72.01 | 81.53 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 87.03 | 79.72 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.41 | 67.32 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.91 | 56.40 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.70 | 49.82 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.98 | 40.50 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 77.75 | 38.95 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.59 | 43.13 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.33 | 53.44 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.18 | 64.29 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.96 | 76.03 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.61 | 92.82 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.18 | 61.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.41 | 38.95 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.33 | 92.82 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 72.01 | 81.53 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 87.03 | 79.72 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 38.41 | 67.32 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.91 | 56.40 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.70 | 49.82 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.98 | 40.50 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 77.75 | 38.95 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 107.59 | 43.13 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.33 | 53.44 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.18 | 64.29 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 62.96 | 76.03 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 48.61 | 92.82 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.18 | 61.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 38.41 | 38.95 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.33 | 92.82 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 86.32 | 96.74 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 104.34 | 94.51 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 46.16 | 79.87 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 130.52 | 66.95 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 86.06 | 59.04 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 79.16 | 48.03 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 93.20 | 46.21 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 128.85 | 51.22 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.22 | 63.45 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 112.81 | 76.29 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 75.47 | 90.17 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.29 | 110.00 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 97.30 | 73.44 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 46.16 | 46.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.22 | 110.00 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 72.76 | 77.13 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 88.00 | 74.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 39.34 | 62.98 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.03 | 52.66 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.17 | 45.53 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 68.02 | 36.62 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.32 | 35.74 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.74 | 40.17 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 142.56 | 49.90 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.04 | 60.54 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 63.57 | 71.95 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.14 | 87.84 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.28 | 57.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 39.34 | 35.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 142.56 | 87.84 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 72.76 | 77.13 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 88.00 | 74.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 39.34 | 62.98 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.03 | 52.66 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.17 | 45.53 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 68.02 | 36.62 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.32 | 35.74 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.74 | 40.17 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 142.56 | 49.90 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.04 | 60.54 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 63.57 | 71.95 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.14 | 87.84 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.28 | 57.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 39.34 | 35.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 142.56 | 87.84 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 87.24 | 91.49 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 105.52 | 88.72 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 47.30 | 74.70 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 131.88 | 62.52 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 87.83 | 53.97 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 81.60 | 43.45 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 95.09 | 42.42 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 130.24 | 47.72 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 170.69 | 59.27 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 113.84 | 71.84 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 76.20 | 85.31 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 58.94 | 104.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 98.63 | 68.70 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 47.30 | 42.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 170.69 | 104.07 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.191180E+09 | 0.230862E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209017E+09 | 0.203019E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.101323E+09 | 0.190441E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.277255E+09 | 0.158156E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185557E+09 | 0.146560E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.163179E+09 | 0.115426E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.203195E+09 | 0.111082E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285715E+09 | 0.119477E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361853E+09 | 0.147185E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247259E+09 | 0.189446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161779E+09 | 0.208850E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128904E+09 | 0.262326E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251622E+10 | 0.208283E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.101323E+09 | 0.111082E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361853E+09 | 0.262326E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.191180E+09 | 0.230862E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209017E+09 | 0.203019E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.101323E+09 | 0.190441E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.277255E+09 | 0.158156E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185557E+09 | 0.146560E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.163179E+09 | 0.115426E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.203195E+09 | 0.111082E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285715E+09 | 0.119477E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361853E+09 | 0.147185E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247259E+09 | 0.189446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161779E+09 | 0.208850E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128904E+09 | 0.262326E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251622E+10 | 0.208283E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.101323E+09 | 0.111082E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361853E+09 | 0.262326E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.191180E+09 | 0.230862E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209017E+09 | 0.203019E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.101323E+09 | 0.190441E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.277255E+09 | 0.158156E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185557E+09 | 0.146560E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.163179E+09 | 0.115426E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.203195E+09 | 0.111082E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285715E+09 | 0.119477E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361853E+09 | 0.147185E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247259E+09 | 0.189446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161779E+09 | 0.208850E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128904E+09 | 0.262326E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251622E+10 | 0.208283E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.101323E+09 | 0.111082E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361853E+09 | 0.262326E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.191180E+09 | 0.230862E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209017E+09 | 0.203019E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.101323E+09 | 0.190441E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.277255E+09 | 0.158156E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185557E+09 | 0.146560E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.163179E+09 | 0.115426E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.203195E+09 | 0.111082E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285715E+09 | 0.119477E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361853E+09 | 0.147185E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247259E+09 | 0.189446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161779E+09 | 0.208850E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128904E+09 | 0.262326E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251622E+10 | 0.208283E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.101323E+09 | 0.111082E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361853E+09 | 0.262326E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.230357E+09 | 0.275629E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.251875E+09 | 0.242182E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.122356E+09 | 0.227362E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.334023E+09 | 0.188903E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.223876E+09 | 0.174774E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.196830E+09 | 0.137747E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.244855E+09 | 0.132637E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.343992E+09 | 0.142796E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.435571E+09 | 0.175847E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.297735E+09 | 0.226212E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.194915E+09 | 0.249273E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.155387E+09 | 0.312839E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.303177E+10 | 0.248620E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.122356E+09 | 0.132637E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.435571E+09 | 0.312839E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.230357E+09 | 0.275629E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.251875E+09 | 0.242182E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.122356E+09 | 0.227362E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.334023E+09 | 0.188903E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.223876E+09 | 0.174774E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.196830E+09 | 0.137747E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.244855E+09 | 0.132637E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.343992E+09 | 0.142796E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.435571E+09 | 0.175847E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.297735E+09 | 0.226212E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.194915E+09 | 0.249273E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.155387E+09 | 0.312839E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.303177E+10 | 0.248620E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.122356E+09 | 0.132637E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.435571E+09 | 0.312839E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.188934E+09 | 0.244167E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.206681E+09 | 0.215431E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 98601708.87 | 0.203819E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.272272E+09 | 0.169240E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.180335E+09 | 0.157503E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.160263E+09 | 0.120048E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201409E+09 | 0.114486E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284320E+09 | 0.122601E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360066E+09 | 0.151063E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.243978E+09 | 0.201271E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.159646E+09 | 0.222682E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.127343E+09 | 0.276895E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.248385E+10 | 0.219921E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 98601708.87 | 0.114486E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360066E+09 | 0.276895E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.188934E+09 | 0.244167E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.206681E+09 | 0.215431E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 98601708.87 | 0.203819E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.272272E+09 | 0.169240E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.180335E+09 | 0.157503E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.160263E+09 | 0.120048E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201409E+09 | 0.114486E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284320E+09 | 0.122601E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360066E+09 | 0.151063E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.243978E+09 | 0.201271E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.159646E+09 | 0.222682E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.127343E+09 | 0.276895E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.248385E+10 | 0.219921E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 98601708.87 | 0.114486E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360066E+09 | 0.276895E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.227647E+09 | 0.291427E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.249057E+09 | 0.256882E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.119065E+09 | 0.243243E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.328055E+09 | 0.202044E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.217629E+09 | 0.187699E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.193331E+09 | 0.143207E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.242708E+09 | 0.136649E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.342314E+09 | 0.146492E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.433438E+09 | 0.180438E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.293819E+09 | 0.240215E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.192358E+09 | 0.265649E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.153503E+09 | 0.330096E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.299292E+10 | 0.262404E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.119065E+09 | 0.136649E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.433438E+09 | 0.330096E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.189930E+09 | 0.235108E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.207554E+09 | 0.207519E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 99564869.79 | 0.195702E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.273988E+09 | 0.164474E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.182068E+09 | 0.153158E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.160696E+09 | 0.120756E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201437E+09 | 0.116327E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284287E+09 | 0.124959E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360364E+09 | 0.152019E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.245386E+09 | 0.194498E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.160641E+09 | 0.213219E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128027E+09 | 0.267151E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.249394E+10 | 0.214489E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 99564869.79 | 0.116327E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360364E+09 | 0.267151E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.189930E+09 | 0.235108E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.207554E+09 | 0.207519E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 99564869.79 | 0.195702E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.273988E+09 | 0.164474E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.182068E+09 | 0.153158E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.160696E+09 | 0.120756E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201437E+09 | 0.116327E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284287E+09 | 0.124959E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360364E+09 | 0.152019E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.245386E+09 | 0.194498E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.160641E+09 | 0.213219E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128027E+09 | 0.267151E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.249394E+10 | 0.214489E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 99564869.79 | 0.116327E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360364E+09 | 0.267151E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.227609E+09 | 0.279081E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.248757E+09 | 0.246108E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.119582E+09 | 0.232288E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.328312E+09 | 0.195244E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.218508E+09 | 0.181494E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.192798E+09 | 0.143179E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.241428E+09 | 0.137986E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.340412E+09 | 0.148385E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.431433E+09 | 0.180489E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.293897E+09 | 0.230847E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.192503E+09 | 0.252985E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.153496E+09 | 0.316751E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.298873E+10 | 0.254484E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.119582E+09 | 0.137986E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.431433E+09 | 0.316751E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.190401E+09 | 0.231659E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.207974E+09 | 0.204638E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.100062E+09 | 0.192632E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.275220E+09 | 0.161229E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.183384E+09 | 0.150003E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.161222E+09 | 0.119440E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201755E+09 | 0.115405E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284454E+09 | 0.124282E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360645E+09 | 0.150870E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.246281E+09 | 0.190570E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161091E+09 | 0.209641E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128342E+09 | 0.263596E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.250083E+10 | 0.211396E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.100062E+09 | 0.115405E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360645E+09 | 0.263596E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.190401E+09 | 0.231659E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.207974E+09 | 0.204638E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.100062E+09 | 0.192632E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.275220E+09 | 0.161229E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.183384E+09 | 0.150003E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.161222E+09 | 0.119440E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.201755E+09 | 0.115405E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284454E+09 | 0.124282E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.360645E+09 | 0.150870E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.246281E+09 | 0.190570E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161091E+09 | 0.209641E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128342E+09 | 0.263596E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.250083E+10 | 0.211396E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.100062E+09 | 0.115405E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.360645E+09 | 0.263596E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.228180E+09 | 0.274971E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.249268E+09 | 0.242677E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.120186E+09 | 0.228630E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.329793E+09 | 0.191393E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.220081E+09 | 0.177754E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.193431E+09 | 0.141617E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.241810E+09 | 0.136893E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.340614E+09 | 0.147582E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.431773E+09 | 0.179124E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.294972E+09 | 0.226180E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.193046E+09 | 0.248725E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.153880E+09 | 0.312518E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.299703E+10 | 0.250806E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.120186E+09 | 0.136893E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.431773E+09 | 0.312518E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.190869E+09 | 0.229165E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.208421E+09 | 0.202566E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.100600E+09 | 0.190364E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.276850E+09 | 0.158029E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185162E+09 | 0.146685E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.162416E+09 | 0.117400E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.202497E+09 | 0.113898E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284915E+09 | 0.123057E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361266E+09 | 0.149224E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247485E+09 | 0.186668E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161532E+09 | 0.207083E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128694E+09 | 0.260851E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251071E+10 | 0.208499E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.100600E+09 | 0.113898E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361266E+09 | 0.260851E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.190869E+09 | 0.229165E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.208421E+09 | 0.202566E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.100600E+09 | 0.190364E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.276850E+09 | 0.158029E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.185162E+09 | 0.146685E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.162416E+09 | 0.117400E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.202497E+09 | 0.113898E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.284915E+09 | 0.123057E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.361266E+09 | 0.149224E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.247485E+09 | 0.186668E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.161532E+09 | 0.207083E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.128694E+09 | 0.260851E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.251071E+10 | 0.208499E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.100600E+09 | 0.113898E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.361266E+09 | 0.260851E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.228750E+09 | 0.271997E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.249812E+09 | 0.240209E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.120839E+09 | 0.225928E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.331744E+09 | 0.187597E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.222207E+09 | 0.173827E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.194866E+09 | 0.139204E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.242704E+09 | 0.135111E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.341172E+09 | 0.146131E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.432522E+09 | 0.177175E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.296412E+09 | 0.221547E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.193580E+09 | 0.245681E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.154307E+09 | 0.309244E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.300892E+10 | 0.247365E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.120839E+09 | 0.135111E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.432522E+09 | 0.309244E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192531E+09 | 0.222120E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210143E+09 | 0.196305E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102355E+09 | 0.184165E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280141E+09 | 0.151225E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.188744E+09 | 0.139396E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.165637E+09 | 0.111672E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.204329E+09 | 0.109362E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285996E+09 | 0.119138E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.363095E+09 | 0.144369E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250325E+09 | 0.178308E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162911E+09 | 0.200427E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129985E+09 | 0.251937E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.253619E+10 | 0.200842E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102355E+09 | 0.109362E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.363095E+09 | 0.251937E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192531E+09 | 0.222120E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210143E+09 | 0.196305E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102355E+09 | 0.184165E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280141E+09 | 0.151225E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.188744E+09 | 0.139396E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.165637E+09 | 0.111672E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.204329E+09 | 0.109362E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285996E+09 | 0.119138E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.363095E+09 | 0.144369E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250325E+09 | 0.178308E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162911E+09 | 0.200427E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129985E+09 | 0.251937E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.253619E+10 | 0.200842E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102355E+09 | 0.109362E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.363095E+09 | 0.251937E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192531E+09 | 0.222120E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210143E+09 | 0.196305E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102355E+09 | 0.184165E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280141E+09 | 0.151225E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.188744E+09 | 0.139396E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.165637E+09 | 0.111672E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.204329E+09 | 0.109362E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285996E+09 | 0.119138E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.363095E+09 | 0.144369E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250325E+09 | 0.178308E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162911E+09 | 0.200427E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129985E+09 | 0.251937E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.253619E+10 | 0.200842E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102355E+09 | 0.109362E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.363095E+09 | 0.251937E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192531E+09 | 0.222120E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210143E+09 | 0.196305E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102355E+09 | 0.184165E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280141E+09 | 0.151225E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.188744E+09 | 0.139396E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.165637E+09 | 0.111672E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.204329E+09 | 0.109362E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.285996E+09 | 0.119138E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.363095E+09 | 0.144369E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250325E+09 | 0.178308E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162911E+09 | 0.200427E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129985E+09 | 0.251937E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.253619E+10 | 0.200842E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102355E+09 | 0.109362E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.363095E+09 | 0.251937E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.230757E+09 | 0.263617E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.251882E+09 | 0.232786E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.122972E+09 | 0.218562E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.335684E+09 | 0.179542E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.226498E+09 | 0.165241E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.198728E+09 | 0.132454E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.244919E+09 | 0.129766E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.342492E+09 | 0.141505E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.434715E+09 | 0.171437E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.299797E+09 | 0.211643E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.195234E+09 | 0.237775E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.155859E+09 | 0.298666E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.303954E+10 | 0.238299E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.122972E+09 | 0.129766E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.434715E+09 | 0.298666E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.230757E+09 | 0.263617E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.251882E+09 | 0.232786E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.122972E+09 | 0.218562E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.335684E+09 | 0.179542E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.226498E+09 | 0.165241E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.198728E+09 | 0.132454E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.244919E+09 | 0.129766E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.342492E+09 | 0.141505E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.434715E+09 | 0.171437E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.299797E+09 | 0.211643E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.195234E+09 | 0.237775E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.155859E+09 | 0.298666E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.303954E+10 | 0.238299E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.122972E+09 | 0.129766E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.434715E+09 | 0.298666E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192152E+09 | 0.222337E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209751E+09 | 0.196620E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102039E+09 | 0.184095E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280676E+09 | 0.150062E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.189797E+09 | 0.138074E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.167522E+09 | 0.109995E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.205722E+09 | 0.108084E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.286708E+09 | 0.118250E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.364168E+09 | 0.142865E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250775E+09 | 0.176917E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162633E+09 | 0.200595E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129673E+09 | 0.252870E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.254162E+10 | 0.200076E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102039E+09 | 0.108084E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.364168E+09 | 0.252870E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192152E+09 | 0.222337E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209751E+09 | 0.196620E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102039E+09 | 0.184095E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.280676E+09 | 0.150062E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.189797E+09 | 0.138074E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.167522E+09 | 0.109995E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.205722E+09 | 0.108084E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.286708E+09 | 0.118250E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.364168E+09 | 0.142865E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250775E+09 | 0.176917E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162633E+09 | 0.200595E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129673E+09 | 0.252870E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.254162E+10 | 0.200076E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102039E+09 | 0.108084E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.364168E+09 | 0.252870E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.230333E+09 | 0.263832E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.251446E+09 | 0.233108E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.122619E+09 | 0.218441E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.336358E+09 | 0.178136E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.227782E+09 | 0.163627E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.200992E+09 | 0.130433E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.246599E+09 | 0.128220E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.343368E+09 | 0.140427E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.436024E+09 | 0.169626E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.300363E+09 | 0.209946E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.194928E+09 | 0.237922E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.155510E+09 | 0.299702E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.304632E+10 | 0.237342E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.122619E+09 | 0.128220E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.436024E+09 | 0.299702E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192330E+09 | 0.221443E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209944E+09 | 0.195798E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102249E+09 | 0.183249E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.281225E+09 | 0.148930E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.190576E+09 | 0.136662E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.168761E+09 | 0.108347E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.206598E+09 | 0.106891E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.287158E+09 | 0.117501E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.364924E+09 | 0.141473E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.251317E+09 | 0.175403E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162776E+09 | 0.199772E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129794E+09 | 0.251950E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.254765E+10 | 0.198742E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102249E+09 | 0.106891E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.364924E+09 | 0.251950E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192330E+09 | 0.221443E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.209944E+09 | 0.195798E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102249E+09 | 0.183249E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.281225E+09 | 0.148930E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.190576E+09 | 0.136662E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.168761E+09 | 0.108347E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.206598E+09 | 0.106891E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.287158E+09 | 0.117501E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.364924E+09 | 0.141473E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.251317E+09 | 0.175403E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.162776E+09 | 0.199772E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.129794E+09 | 0.251950E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.254765E+10 | 0.198742E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102249E+09 | 0.106891E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.364924E+09 | 0.251950E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.230550E+09 | 0.262763E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.251681E+09 | 0.232128E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.122876E+09 | 0.217432E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.337020E+09 | 0.176788E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.228719E+09 | 0.161954E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.202474E+09 | 0.128479E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.247649E+09 | 0.126805E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.343910E+09 | 0.139539E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.436931E+09 | 0.167974E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.301011E+09 | 0.208146E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.195102E+09 | 0.236939E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.155657E+09 | 0.298603E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.305358E+10 | 0.235755E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.122876E+09 | 0.126805E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.436931E+09 | 0.298603E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192866E+09 | 0.218374E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210550E+09 | 0.192867E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102872E+09 | 0.180305E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.282294E+09 | 0.146183E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.192052E+09 | 0.133425E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171023E+09 | 0.104980E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.208253E+09 | 0.104317E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.288166E+09 | 0.115507E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366329E+09 | 0.138516E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.252261E+09 | 0.172202E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.163196E+09 | 0.197069E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.130184E+09 | 0.248605E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.256005E+10 | 0.195235E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102872E+09 | 0.104317E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366329E+09 | 0.248605E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.192866E+09 | 0.218374E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.210550E+09 | 0.192867E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.102872E+09 | 0.180305E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.282294E+09 | 0.146183E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.192052E+09 | 0.133425E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171023E+09 | 0.104980E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.208253E+09 | 0.104317E+09 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.288166E+09 | 0.115507E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366329E+09 | 0.138516E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.252261E+09 | 0.172202E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.163196E+09 | 0.197069E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.130184E+09 | 0.248605E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.256005E+10 | 0.195235E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.102872E+09 | 0.104317E+09 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366329E+09 | 0.248605E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.231202E+09 | 0.259106E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.252418E+09 | 0.228638E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.123638E+09 | 0.213928E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.338308E+09 | 0.173527E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.230495E+09 | 0.158121E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.205180E+09 | 0.124496E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.249631E+09 | 0.123758E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.345122E+09 | 0.137177E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.438612E+09 | 0.164471E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.302144E+09 | 0.204345E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.195612E+09 | 0.233722E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.156129E+09 | 0.294618E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.306849E+10 | 0.231591E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.123638E+09 | 0.123758E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.438612E+09 | 0.294618E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.194889E+09 | 0.206583E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.212895E+09 | 0.181090E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.105378E+09 | 0.168677E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285195E+09 | 0.136507E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.195989E+09 | 0.121938E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.176302E+09 | 94931388.20 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.212463E+09 | 95719997.90 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291249E+09 | 0.107591E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.369518E+09 | 0.129348E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254548E+09 | 0.162160E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.164763E+09 | 0.186483E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.131616E+09 | 0.235263E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259481E+10 | 0.182629E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.105378E+09 | 94931388.20 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.369518E+09 | 0.235263E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.194889E+09 | 0.206583E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.212895E+09 | 0.181090E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.105378E+09 | 0.168677E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285195E+09 | 0.136507E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.195989E+09 | 0.121938E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.176302E+09 | 94931388.20 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.212463E+09 | 95719997.90 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291249E+09 | 0.107591E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.369518E+09 | 0.129348E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254548E+09 | 0.162160E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.164763E+09 | 0.186483E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.131616E+09 | 0.235263E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259481E+10 | 0.182629E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.105378E+09 | 94931388.20 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.369518E+09 | 0.235263E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.233665E+09 | 0.245050E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.255272E+09 | 0.214635E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.126696E+09 | 0.200076E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.341821E+09 | 0.162042E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.235253E+09 | 0.144554E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.211503E+09 | 0.112633E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.254677E+09 | 0.113613E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.348825E+09 | 0.127821E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.442434E+09 | 0.153632E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.304902E+09 | 0.192426E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.197512E+09 | 0.221134E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.157868E+09 | 0.278753E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.311043E+10 | 0.216637E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.126696E+09 | 0.112633E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.442434E+09 | 0.278753E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 457.52 | 550.59 | 497.16 | 321.78 | 175.38 | 0.00 | 0.00 |
February | 553.83 | 535.90 | 607.38 | 370.64 | 236.74 | 0.00 | 0.00 |
March | 242.68 | 454.18 | 375.58 | 109.41 | 266.18 | 0.00 | 0.00 |
April | 685.60 | 389.83 | 779.84 | 352.52 | 427.32 | 0.00 | 0.00 |
May | 444.29 | 349.38 | 644.84 | 209.88 | 434.97 | 0.00 | 0.00 |
June | 403.69 | 284.41 | 594.04 | 143.73 | 450.31 | 0.00 | 0.00 |
July | 486.29 | 264.94 | 643.63 | 201.49 | 442.14 | 0.00 | 0.00 |
August | 683.56 | 285.06 | 754.29 | 339.30 | 414.99 | 0.00 | 0.00 |
September | 894.50 | 362.82 | 891.71 | 522.51 | 369.20 | 0.00 | 0.00 |
October | 591.59 | 451.84 | 612.56 | 358.07 | 254.49 | 0.00 | 0.00 |
November | 400.06 | 514.64 | 434.10 | 264.04 | 170.07 | 0.00 | 0.00 |
December | 308.54 | 625.37 | 344.02 | 220.37 | 123.65 | 0.00 | 0.00 |
Annual Sum or Average | 511.43 | 421.86 | 597.35 | 283.37 | 313.98 | 0.00 | 0.00 |
Minimum of Months | 242.68 | 264.94 | 344.02 | 109.41 | 123.65 | 0.00 | 0.00 |
Maximum of Months | 894.50 | 625.37 | 891.71 | 522.51 | 450.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 226.07 | 291.13 | 248.58 | 160.89 | 87.69 | 0.00 | 0.00 |
February | 273.82 | 284.29 | 303.69 | 185.32 | 118.37 | 0.00 | 0.00 |
March | 118.08 | 243.01 | 187.79 | 54.70 | 133.09 | 0.00 | 0.00 |
April | 336.65 | 208.54 | 389.92 | 176.26 | 213.66 | 0.00 | 0.00 |
May | 215.91 | 187.69 | 322.42 | 104.94 | 217.48 | 0.00 | 0.00 |
June | 198.25 | 147.88 | 297.02 | 71.86 | 225.16 | 0.00 | 0.00 |
July | 241.01 | 136.51 | 321.81 | 100.75 | 221.07 | 0.00 | 0.00 |
August | 340.11 | 146.24 | 377.14 | 169.65 | 207.50 | 0.00 | 0.00 |
September | 445.05 | 186.17 | 445.86 | 261.26 | 184.60 | 0.00 | 0.00 |
October | 291.88 | 239.98 | 306.28 | 179.04 | 127.24 | 0.00 | 0.00 |
November | 197.40 | 274.31 | 217.05 | 132.02 | 85.03 | 0.00 | 0.00 |
December | 152.40 | 330.01 | 172.01 | 110.19 | 61.83 | 0.00 | 0.00 |
Annual Sum or Average | 252.43 | 222.68 | 298.67 | 141.69 | 156.99 | 0.00 | 0.00 |
Minimum of Months | 118.08 | 136.51 | 172.01 | 54.70 | 61.83 | 0.00 | 0.00 |
Maximum of Months | 445.05 | 330.01 | 445.86 | 261.26 | 225.16 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 226.80 | 279.76 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 274.41 | 273.29 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 118.99 | 232.86 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 338.07 | 202.23 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 217.53 | 182.13 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 198.38 | 148.41 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 240.55 | 138.38 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 339.38 | 148.71 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 444.51 | 186.93 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 292.96 | 231.42 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 198.22 | 262.12 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 152.91 | 317.75 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 252.94 | 216.72 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 118.99 | 138.38 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 444.51 | 317.75 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 227.37 | 275.65 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 274.97 | 269.49 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 119.59 | 229.20 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 339.60 | 198.24 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 219.10 | 178.37 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 199.03 | 146.80 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 240.93 | 137.28 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 339.58 | 147.90 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 444.85 | 185.52 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 294.03 | 226.75 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 198.78 | 257.72 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 153.29 | 313.51 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 253.64 | 213.60 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 119.59 | 137.28 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 444.85 | 313.51 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 227.93 | 272.67 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 275.57 | 266.76 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 120.24 | 226.50 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 341.61 | 194.31 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 221.23 | 174.43 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 200.50 | 144.29 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 241.82 | 135.49 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 340.13 | 146.45 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 445.62 | 183.50 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 295.47 | 222.10 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 199.32 | 254.57 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 153.71 | 310.24 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 254.64 | 210.67 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 120.24 | 135.49 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 445.62 | 310.24 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 459.84 | 528.57 | 496.14 | 321.12 | 175.02 | 0.00 | 0.00 |
February | 555.70 | 517.03 | 606.13 | 369.88 | 236.25 | 0.00 | 0.00 |
March | 244.68 | 438.24 | 374.81 | 109.18 | 265.63 | 0.00 | 0.00 |
April | 691.33 | 371.91 | 778.24 | 351.80 | 426.44 | 0.00 | 0.00 |
May | 451.00 | 331.57 | 643.52 | 209.44 | 434.08 | 0.00 | 0.00 |
June | 408.95 | 274.54 | 592.82 | 143.43 | 449.39 | 0.00 | 0.00 |
July | 488.03 | 260.22 | 642.31 | 201.08 | 441.23 | 0.00 | 0.00 |
August | 682.86 | 283.59 | 752.74 | 338.60 | 414.14 | 0.00 | 0.00 |
September | 895.76 | 355.07 | 889.88 | 521.44 | 368.44 | 0.00 | 0.00 |
October | 597.71 | 424.33 | 611.31 | 357.34 | 253.97 | 0.00 | 0.00 |
November | 402.05 | 492.77 | 433.21 | 263.49 | 169.72 | 0.00 | 0.00 |
December | 310.51 | 599.27 | 343.32 | 219.92 | 123.40 | 0.00 | 0.00 |
Annual Sum or Average | 514.45 | 405.87 | 596.12 | 282.79 | 313.33 | 0.00 | 0.00 |
Minimum of Months | 244.68 | 260.22 | 343.32 | 109.18 | 123.40 | 0.00 | 0.00 |
Maximum of Months | 895.76 | 599.27 | 889.88 | 521.44 | 449.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 229.48 | 264.53 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 277.34 | 258.91 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 121.97 | 219.02 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 346.34 | 184.51 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 226.77 | 164.19 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 206.80 | 135.19 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 245.68 | 128.58 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 342.29 | 140.73 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 449.21 | 175.68 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 299.40 | 210.49 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 200.69 | 246.57 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 154.89 | 300.72 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 257.79 | 202.15 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 121.97 | 128.58 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 449.21 | 300.72 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 229.69 | 263.46 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 277.60 | 257.82 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 122.23 | 218.01 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 347.02 | 183.12 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 227.70 | 162.51 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 208.33 | 133.17 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 246.73 | 127.16 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 342.83 | 139.84 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 450.15 | 173.97 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 300.05 | 208.69 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 200.87 | 245.56 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 155.03 | 299.62 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 258.40 | 200.80 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 122.23 | 127.16 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 450.15 | 299.62 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 230.34 | 259.80 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 278.41 | 253.96 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 122.98 | 214.51 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 348.34 | 179.74 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 229.47 | 158.67 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 211.12 | 129.03 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 248.71 | 124.10 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 344.03 | 137.47 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 451.88 | 170.33 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 301.17 | 204.88 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 201.39 | 242.23 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 155.50 | 295.63 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 259.66 | 197.25 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 122.98 | 124.10 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 451.88 | 295.63 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 232.77 | 245.75 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 281.52 | 238.43 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 125.99 | 200.65 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 351.93 | 167.85 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 234.18 | 145.02 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 217.63 | 116.70 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 253.73 | 113.89 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 347.72 | 128.06 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 455.81 | 159.08 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 303.91 | 192.93 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 203.33 | 229.21 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 157.22 | 279.75 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 263.19 | 184.52 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 125.99 | 113.89 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 455.81 | 279.75 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.122543E+10 | 0.147470E+10 | 0.133159E+10 | 0.861863E+09 | 0.469725E+09 | 0.00 | 0.00 |
February | 0.133981E+10 | 0.129644E+10 | 0.146938E+10 | 0.896661E+09 | 0.572716E+09 | 0.00 | 0.00 |
March | 0.650002E+09 | 0.121649E+10 | 0.100596E+10 | 0.293038E+09 | 0.712924E+09 | 0.00 | 0.00 |
April | 0.177707E+10 | 0.101043E+10 | 0.202136E+10 | 0.913739E+09 | 0.110762E+10 | 0.00 | 0.00 |
May | 0.118998E+10 | 0.935787E+09 | 0.172715E+10 | 0.562129E+09 | 0.116502E+10 | 0.00 | 0.00 |
June | 0.104637E+10 | 0.737197E+09 | 0.153976E+10 | 0.372543E+09 | 0.116722E+10 | 0.00 | 0.00 |
July | 0.130249E+10 | 0.709603E+09 | 0.172389E+10 | 0.539676E+09 | 0.118422E+10 | 0.00 | 0.00 |
August | 0.183084E+10 | 0.763502E+09 | 0.202028E+10 | 0.908771E+09 | 0.111151E+10 | 0.00 | 0.00 |
September | 0.231855E+10 | 0.940435E+09 | 0.231132E+10 | 0.135435E+10 | 0.956967E+09 | 0.00 | 0.00 |
October | 0.158450E+10 | 0.121021E+10 | 0.164069E+10 | 0.959064E+09 | 0.681625E+09 | 0.00 | 0.00 |
November | 0.103695E+10 | 0.133395E+10 | 0.112520E+10 | 0.684381E+09 | 0.440817E+09 | 0.00 | 0.00 |
December | 0.826390E+09 | 0.167498E+10 | 0.921433E+09 | 0.590245E+09 | 0.331188E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.161284E+11 | 0.133037E+11 | 0.188380E+11 | 0.893646E+10 | 0.990155E+10 | 0.00 | 0.00 |
Minimum of Months | 0.650002E+09 | 0.709603E+09 | 0.921433E+09 | 0.293038E+09 | 0.331188E+09 | 0.00 | 0.00 |
Maximum of Months | 0.231855E+10 | 0.167498E+10 | 0.231132E+10 | 0.135435E+10 | 0.118422E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.605516E+09 | 0.779761E+09 | 0.665794E+09 | 0.430932E+09 | 0.234862E+09 | 0.00 | 0.00 |
February | 0.662418E+09 | 0.687743E+09 | 0.734689E+09 | 0.448330E+09 | 0.286358E+09 | 0.00 | 0.00 |
March | 0.316269E+09 | 0.650881E+09 | 0.502981E+09 | 0.146519E+09 | 0.356462E+09 | 0.00 | 0.00 |
April | 0.872599E+09 | 0.540524E+09 | 0.101068E+10 | 0.456869E+09 | 0.553810E+09 | 0.00 | 0.00 |
May | 0.578299E+09 | 0.502704E+09 | 0.863575E+09 | 0.281065E+09 | 0.582511E+09 | 0.00 | 0.00 |
June | 0.513857E+09 | 0.383304E+09 | 0.769879E+09 | 0.186272E+09 | 0.583608E+09 | 0.00 | 0.00 |
July | 0.645525E+09 | 0.365620E+09 | 0.861947E+09 | 0.269838E+09 | 0.592109E+09 | 0.00 | 0.00 |
August | 0.910953E+09 | 0.391694E+09 | 0.101014E+10 | 0.454385E+09 | 0.555756E+09 | 0.00 | 0.00 |
September | 0.115357E+10 | 0.482563E+09 | 0.115566E+10 | 0.677176E+09 | 0.478483E+09 | 0.00 | 0.00 |
October | 0.781773E+09 | 0.642757E+09 | 0.820345E+09 | 0.479532E+09 | 0.340813E+09 | 0.00 | 0.00 |
November | 0.511649E+09 | 0.711012E+09 | 0.562599E+09 | 0.342191E+09 | 0.220409E+09 | 0.00 | 0.00 |
December | 0.408189E+09 | 0.883886E+09 | 0.460717E+09 | 0.295123E+09 | 0.165594E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.796062E+10 | 0.702245E+10 | 0.941900E+10 | 0.446823E+10 | 0.495077E+10 | 0.00 | 0.00 |
Minimum of Months | 0.316269E+09 | 0.365620E+09 | 0.460717E+09 | 0.146519E+09 | 0.165594E+09 | 0.00 | 0.00 |
Maximum of Months | 0.115357E+10 | 0.883886E+09 | 0.115566E+10 | 0.677176E+09 | 0.592109E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.607470E+09 | 0.749297E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.663863E+09 | 0.661145E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.318711E+09 | 0.623691E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.876288E+09 | 0.524191E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.582644E+09 | 0.487809E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.514188E+09 | 0.384690E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.644302E+09 | 0.370640E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.908985E+09 | 0.398301E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.115216E+10 | 0.484528E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.784667E+09 | 0.619841E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.513786E+09 | 0.679422E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.409550E+09 | 0.851052E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.797662E+10 | 0.683461E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.318711E+09 | 0.370640E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.115216E+10 | 0.851052E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.608980E+09 | 0.738288E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.665216E+09 | 0.651952E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.320308E+09 | 0.613894E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.880233E+09 | 0.513850E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.586850E+09 | 0.477759E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.515874E+09 | 0.380497E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.645319E+09 | 0.367702E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.909521E+09 | 0.396146E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.115306E+10 | 0.480864E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.787533E+09 | 0.607319E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.515228E+09 | 0.668006E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.410564E+09 | 0.839710E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.799869E+10 | 0.673599E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.320308E+09 | 0.367702E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.115306E+10 | 0.839710E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.610488E+09 | 0.730327E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.666655E+09 | 0.645341E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.322040E+09 | 0.606655E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.885444E+09 | 0.503655E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.592530E+09 | 0.467197E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.519698E+09 | 0.374003E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.647698E+09 | 0.362908E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.911002E+09 | 0.392244E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.115505E+10 | 0.475622E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.791382E+09 | 0.594882E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.516644E+09 | 0.659847E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.411695E+09 | 0.830947E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.803033E+10 | 0.664363E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.322040E+09 | 0.362908E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.115505E+10 | 0.830947E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.123164E+10 | 0.141571E+10 | 0.132885E+10 | 0.860093E+09 | 0.468760E+09 | 0.00 | 0.00 |
February | 0.134434E+10 | 0.125079E+10 | 0.146636E+10 | 0.894820E+09 | 0.571540E+09 | 0.00 | 0.00 |
March | 0.655362E+09 | 0.117378E+10 | 0.100390E+10 | 0.292436E+09 | 0.711460E+09 | 0.00 | 0.00 |
April | 0.179193E+10 | 0.963981E+09 | 0.201721E+10 | 0.911862E+09 | 0.110534E+10 | 0.00 | 0.00 |
May | 0.120797E+10 | 0.888066E+09 | 0.172360E+10 | 0.560975E+09 | 0.116263E+10 | 0.00 | 0.00 |
June | 0.106000E+10 | 0.711596E+09 | 0.153660E+10 | 0.371778E+09 | 0.116482E+10 | 0.00 | 0.00 |
July | 0.130715E+10 | 0.696979E+09 | 0.172035E+10 | 0.538568E+09 | 0.118179E+10 | 0.00 | 0.00 |
August | 0.182897E+10 | 0.759561E+09 | 0.201614E+10 | 0.906905E+09 | 0.110923E+10 | 0.00 | 0.00 |
September | 0.232181E+10 | 0.920348E+09 | 0.230657E+10 | 0.135157E+10 | 0.955002E+09 | 0.00 | 0.00 |
October | 0.160089E+10 | 0.113652E+10 | 0.163732E+10 | 0.957094E+09 | 0.680226E+09 | 0.00 | 0.00 |
November | 0.104211E+10 | 0.127726E+10 | 0.112289E+10 | 0.682976E+09 | 0.439912E+09 | 0.00 | 0.00 |
December | 0.831657E+09 | 0.160508E+10 | 0.919541E+09 | 0.589033E+09 | 0.330508E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.162238E+11 | 0.127997E+11 | 0.187993E+11 | 0.891811E+10 | 0.988122E+10 | 0.00 | 0.00 |
Minimum of Months | 0.655362E+09 | 0.696979E+09 | 0.919541E+09 | 0.292436E+09 | 0.330508E+09 | 0.00 | 0.00 |
Maximum of Months | 0.232181E+10 | 0.160508E+10 | 0.230657E+10 | 0.135157E+10 | 0.118179E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.614635E+09 | 0.708506E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.670946E+09 | 0.626348E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.326694E+09 | 0.586628E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.897709E+09 | 0.478260E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.607376E+09 | 0.439774E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.536035E+09 | 0.350423E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.658042E+09 | 0.344389E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.916785E+09 | 0.376926E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.116436E+10 | 0.455356E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.801913E+09 | 0.563779E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.520193E+09 | 0.639112E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.414856E+09 | 0.805441E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.812954E+10 | 0.637494E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.326694E+09 | 0.344389E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.116436E+10 | 0.805441E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.615209E+09 | 0.705649E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.671569E+09 | 0.623724E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.327373E+09 | 0.583929E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.899470E+09 | 0.474647E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.609870E+09 | 0.435278E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.539994E+09 | 0.345171E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.660845E+09 | 0.340587E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.918226E+09 | 0.374541E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.116678E+10 | 0.450921E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.803645E+09 | 0.558952E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.520653E+09 | 0.636482E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.415245E+09 | 0.802504E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.814888E+10 | 0.633239E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.327373E+09 | 0.340587E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.116678E+10 | 0.802504E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.616933E+09 | 0.695854E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.673518E+09 | 0.614371E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.329381E+09 | 0.574536E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.902895E+09 | 0.465893E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.614599E+09 | 0.424970E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.547226E+09 | 0.334456E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.666136E+09 | 0.332392E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.921454E+09 | 0.368190E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.117127E+10 | 0.441503E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.806666E+09 | 0.548747E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.522003E+09 | 0.627860E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.416497E+09 | 0.791828E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.818858E+10 | 0.622060E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.329381E+09 | 0.332392E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117127E+10 | 0.791828E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.623441E+09 | 0.658215E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.681061E+09 | 0.576813E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.337451E+09 | 0.537430E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.912211E+09 | 0.435056E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.627231E+09 | 0.388430E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.564107E+09 | 0.302495E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.679603E+09 | 0.305052E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.931323E+09 | 0.343004E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.118147E+10 | 0.412328E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.813998E+09 | 0.516746E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.527037E+09 | 0.594100E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.421099E+09 | 0.749277E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.830003E+10 | 0.581895E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.337451E+09 | 0.302495E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.118147E+10 | 0.749277E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 4.18 | 3.24 | 2.03 | 1.05 | -4.0 | 28.28 | 62.93 | 0.00 |
February | 4.25 | 3.55 | 2.74 | 1.60 | -5.0 | 43.80 | 86.73 | 0.02 |
March | 5.90 | 4.45 | 2.76 | 1.18 | -2.0 | 68.95 | 35.00 | 0.00 |
April | 8.96 | 6.23 | 3.38 | 1.56 | -0.7 | 96.13 | 186.12 | 0.00 |
May | 9.99 | 8.06 | 6.28 | 3.35 | -0.9 | 110.92 | 199.68 | 0.02 |
June | 13.31 | 11.26 | 9.70 | 3.33 | 3.35 | 121.69 | 199.28 | 0.00 |
July | 15.02 | 12.39 | 10.49 | 3.21 | 4.48 | 111.91 | 220.83 | 0.00 |
August | 15.65 | 12.74 | 10.65 | 2.92 | 3.94 | 91.47 | 211.91 | 0.00 |
September | 13.43 | 11.01 | 9.10 | 2.64 | 1.42 | 68.72 | 198.32 | 0.01 |
October | 9.33 | 8.03 | 6.81 | 1.97 | -1.0 | 48.92 | 91.86 | 0.04 |
November | 6.66 | 5.65 | 4.54 | 2.05 | -2.3 | 30.27 | 53.24 | 0.04 |
December | 4.10 | 3.14 | 1.95 | 2.36 | -5.1 | 20.52 | 40.74 | 0.04 |
Annual Sum or Average | 9.26 | 7.50 | 5.89 | 2.27 | -0.6 | 70.25 | 132.30 | 0.02 |
Minimum of Months | 4.10 | 3.14 | 1.95 | 1.05 | -5.1 | 20.52 | 35.00 | 0.00 |
Maximum of Months | 15.65 | 12.74 | 10.65 | 3.35 | 4.48 | 121.69 | 220.83 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 29-JAN-05:00 | 9.36 | 5.00 | 3.60 | 8.35 | 0.00 | 0.00 |
February | 11.00 | 07-FEB-14:00 | 9.86 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 14.00 | 25-MAR-12:00 | 11.21 | 9.00 | 2.60 | 7.35 | 287.00 | 93.00 |
April | 24.00 | 30-APR-14:00 | 13.10 | 4.00 | 1.50 | 7.75 | 167.50 | 716.00 |
May | 24.00 | 22-MAY-14:00 | 16.06 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 27.00 | 13-JUN-16:00 | 17.51 | 12.00 | 3.10 | 12.41 | 141.50 | 652.50 |
July | 30.00 | 22-JUL-17:00 | 16.77 | 8.00 | 0.00 | 14.28 | 122.00 | 407.00 |
August | 27.00 | 14-AUG-17:19 | 14.15 | 3.33 | 2.60 | 10.37 | 133.00 | 358.83 |
September | 23.00 | 11-SEP-16:00 | 16.21 | 12.00 | 2.60 | 8.74 | 108.00 | 325.50 |
October | 19.00 | 07-OCT-14:00 | 10.08 | 1.00 | 1.50 | 2.22 | 131.00 | 540.50 |
November | 16.00 | 24-NOV-11:00 | 12.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 13.00 | 23-DEC-10:00 | 7.62 | 2.00 | 7.70 | 6.75 | 70.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.00 | 7.62 | 1.00 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 30.00 | 17.51 | 12.00 | 7.70 | 14.28 | 287.00 | 769.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.0 | 10-JAN-07:00 | -6.9 | -9.0 | 0.00 | -20.0 | 0.00 | 0.00 |
February | -4.0 | 17-FEB-06:00 | -4.0 | -4.0 | 0.00 | -20.5 | 0.00 | 0.00 |
March | -1.0 | 08-MAR-06:00 | -1.4 | -2.0 | 0.00 | -14.4 | 17.50 | 184.50 |
April | 0.00 | 08-APR-04:00 | -0.8 | -2.0 | 0.00 | -12.7 | 0.00 | 0.00 |
May | 2.00 | 06-MAY-04:00 | 1.57 | 1.00 | 3.60 | -13.7 | 12.50 | 117.00 |
June | 6.00 | 01-JUN-03:00 | 5.04 | 4.00 | 0.00 | -9.2 | 0.00 | 0.00 |
July | 7.00 | 05-JUL-04:00 | 6.47 | 6.00 | 3.10 | -7.8 | 28.00 | 155.00 |
August | 8.00 | 20-AUG-04:00 | 7.45 | 7.00 | 0.00 | -6.6 | 0.00 | 0.00 |
September | 5.00 | 20-SEP-03:00 | 5.00 | 5.00 | 2.60 | -10.0 | 0.00 | 0.00 |
October | 2.00 | 07-OCT-03:00 | 2.00 | 2.00 | 0.00 | -13.4 | 0.00 | 0.00 |
November | -2.0 | 29-NOV-01:00 | -2.0 | -2.0 | 3.10 | -10.7 | 0.00 | 0.00 |
December | -3.0 | 29-DEC-20:00 | -4.4 | -7.0 | 3.60 | -20.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -6.0 | -6.9 | -9.0 | 0.00 | -20.5 | 0.00 | 0.00 | |
Maximum of Months | 8.00 | 7.45 | 7.00 | 3.60 | -6.6 | 28.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.44 | 29-JAN-04:00 | 13.00 | 12.00 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.86 | 07-FEB-14:00 | 11.00 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.39 | 28-APR-07:00 | 16.00 | 15.00 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 16.06 | 22-MAY-14:00 | 24.00 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 19.93 | 25-JUN-17:00 | 22.00 | 19.00 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 17.29 | 22-JUL-09:00 | 26.00 | 12.00 | 4.60 | 11.46 | 224.50 | 619.50 |
August | 17.04 | 14-AUG-12:00 | 24.00 | 13.00 | 2.60 | 9.91 | 205.50 | 669.50 |
September | 16.53 | 10-SEP-15:00 | 21.00 | 14.00 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.58 | 17-OCT-14:00 | 16.00 | 12.00 | 0.00 | 12.03 | 144.00 | 44.50 |
November | 12.00 | 24-NOV-11:00 | 16.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 7.93 | 02-DEC-12:00 | 9.00 | 7.00 | 0.00 | 2.01 | 135.50 | 84.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.93 | 9.00 | 7.00 | 0.00 | 2.01 | 0.00 | 0.00 | |
Maximum of Months | 19.93 | 26.00 | 19.00 | 4.60 | 15.94 | 224.50 | 769.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.00 | 29-JAN-04:00 | 13.00 | 12.44 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.00 | 07-FEB-14:00 | 11.00 | 9.86 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.00 | 28-APR-07:00 | 16.00 | 15.39 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 12.00 | 23-MAY-07:00 | 17.00 | 13.94 | 3.10 | 5.13 | 112.00 | 719.50 |
June | 19.00 | 25-JUN-17:00 | 22.00 | 19.93 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 14.00 | 17-JUL-17:00 | 18.00 | 15.44 | 3.60 | 9.91 | 120.00 | 0.00 |
August | 16.00 | 08-AUG-12:00 | 18.00 | 16.70 | 1.50 | 11.46 | 154.00 | 0.00 |
September | 14.00 | 10-SEP-15:00 | 21.00 | 16.53 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.00 | 17-OCT-18:00 | 13.00 | 13.00 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 12.00 | 08-NOV-14:00 | 12.00 | 12.00 | 0.00 | 8.15 | 93.00 | 106.00 |
December | 7.00 | 02-DEC-11:00 | 8.00 | 7.45 | 3.10 | 1.16 | 144.50 | 146.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.00 | 8.00 | 7.45 | 0.00 | 1.16 | 0.00 | 0.00 | |
Maximum of Months | 19.00 | 22.00 | 19.93 | 3.60 | 15.94 | 160.50 | 719.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.33 | 8.85 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 10.00 | 14.79 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.33 | 17.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 11.26 | 40.86 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.54 | 47.73 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 13.82 | 50.98 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 14.77 | 51.67 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 15.12 | 44.67 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 14.78 | 34.25 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.84 | 17.71 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.55 | 9.34 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 11.27 | 6.14 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.57 | 28.73 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 10.00 | 6.14 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 15.12 | 51.67 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.362100E+09 | -238918568.8 | 0.00 | 0.00 | 744.00 | 0.00 | -123181010.2 | 58.99 | 0.00 | 0.00 |
February | 0.329929E+09 | -218406152.1 | 0.00 | 0.00 | 672.00 | 0.00 | -111522576.6 | 58.99 | 0.00 | 0.00 |
March | 0.366935E+09 | -243934337.2 | 0.00 | 0.00 | 744.00 | 0.00 | -123000685.5 | 58.99 | 0.00 | 0.00 |
April | 0.344384E+09 | -228938498.1 | 0.00 | 0.00 | 720.00 | 0.00 | -115445028.4 | 58.99 | 0.00 | 0.00 |
May | 0.348986E+09 | -230433834.5 | 0.00 | 0.00 | 744.00 | 0.00 | -118552314.0 | 58.99 | 0.00 | 0.00 |
June | 0.329520E+09 | -218891838.1 | 0.00 | 0.00 | 720.00 | 0.00 | -110627969.7 | 58.99 | 0.00 | 0.00 |
July | 0.330720E+09 | -217252908.8 | 0.00 | 0.00 | 744.00 | 0.00 | -113466619.7 | 58.99 | 0.00 | 0.00 |
August | 0.332964E+09 | -219766332.3 | 0.00 | 0.00 | 744.00 | 0.00 | -113197468.5 | 58.99 | 0.00 | 0.00 |
September | 0.322259E+09 | -212234003.1 | 0.00 | 0.00 | 720.00 | 0.00 | -110024713.9 | 58.99 | 0.00 | 0.00 |
October | 0.340602E+09 | -221701469.5 | 0.00 | 0.00 | 744.00 | 0.00 | -118900939.7 | 59.00 | 0.00 | 0.00 |
November | 0.338705E+09 | -220049375.2 | 0.00 | 0.00 | 720.00 | 0.00 | -118655850.0 | 58.99 | 0.00 | 0.00 |
December | 0.358225E+09 | -234596305.6 | 0.00 | 0.00 | 744.00 | 0.00 | -123628316.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.410533E+10 | -.270512E+10 | 8760.00 | -.140020E+10 | 58.99 | |||||
Minimum of Months | 0.322259E+09 | -243934337.2 | 0.00 | 0.00 | 672.00 | 0.00 | -123628316.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.366935E+09 | -212234003.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110024713.9 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.359656E+09 | -238919004.5 | 0.00 | 0.00 | 744.00 | 0.00 | -120736729.6 | 58.99 | 0.00 | 0.00 |
February | 0.327674E+09 | -218406830.0 | 0.00 | 0.00 | 672.00 | 0.00 | -109267090.4 | 58.99 | 0.00 | 0.00 |
March | 0.364319E+09 | -243944903.6 | 0.00 | 0.00 | 744.00 | 0.00 | -120373863.1 | 58.99 | 0.00 | 0.00 |
April | 0.341619E+09 | -228945026.0 | 0.00 | 0.00 | 720.00 | 0.00 | -112673755.9 | 58.99 | 0.00 | 0.00 |
May | 0.346285E+09 | -230436975.0 | 0.00 | 0.00 | 744.00 | 0.00 | -115847950.2 | 58.99 | 0.00 | 0.00 |
June | 0.328497E+09 | -218891206.5 | 0.00 | 0.00 | 720.00 | 0.00 | -109606274.1 | 58.99 | 0.00 | 0.00 |
July | 0.330087E+09 | -217254552.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112832682.3 | 58.99 | 0.00 | 0.00 |
August | 0.332468E+09 | -219766537.1 | 0.00 | 0.00 | 744.00 | 0.00 | -112701328.9 | 58.99 | 0.00 | 0.00 |
September | 0.321581E+09 | -212231618.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109349428.0 | 58.99 | 0.00 | 0.00 |
October | 0.338033E+09 | -221705645.8 | 0.00 | 0.00 | 744.00 | 0.00 | -116327702.4 | 59.00 | 0.00 | 0.00 |
November | 0.336037E+09 | -220046106.9 | 0.00 | 0.00 | 720.00 | 0.00 | -115991362.3 | 58.99 | 0.00 | 0.00 |
December | 0.355846E+09 | -234597038.6 | 0.00 | 0.00 | 744.00 | 0.00 | -121248954.0 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.408210E+10 | -.270515E+10 | 8760.00 | -.137696E+10 | 58.99 | |||||
Minimum of Months | 0.321581E+09 | -243944903.6 | 0.00 | 0.00 | 672.00 | 0.00 | -121248954.0 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.364319E+09 | -212231618.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109267090.4 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.332960E+09 | -210101245.6 | 0.00 | 0.00 | 744.00 | 0.00 | -122858916.9 | 58.99 | 0.00 | 0.00 |
February | 0.303323E+09 | -192213818.8 | 0.00 | 0.00 | 672.00 | 0.00 | -111109535.0 | 58.99 | 0.00 | 0.00 |
March | 0.340253E+09 | -217875759.8 | 0.00 | 0.00 | 744.00 | 0.00 | -122377296.1 | 58.99 | 0.00 | 0.00 |
April | 0.315197E+09 | -201192576.5 | 0.00 | 0.00 | 720.00 | 0.00 | -114004107.4 | 58.99 | 0.00 | 0.00 |
May | 0.321395E+09 | -204359586.0 | 0.00 | 0.00 | 744.00 | 0.00 | -117035438.3 | 58.99 | 0.00 | 0.00 |
June | 0.304477E+09 | -195101128.8 | 0.00 | 0.00 | 720.00 | 0.00 | -109375955.2 | 58.99 | 0.00 | 0.00 |
July | 0.302004E+09 | -189792075.6 | 0.00 | 0.00 | 744.00 | 0.00 | -112211635.5 | 58.99 | 0.00 | 0.00 |
August | 0.308430E+09 | -196434931.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111995234.5 | 58.99 | 0.00 | 0.00 |
September | 0.295424E+09 | -186372886.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109050837.0 | 58.99 | 0.00 | 0.00 |
October | 0.312935E+09 | -194973982.1 | 0.00 | 0.00 | 744.00 | 0.00 | -117960985.5 | 58.99 | 0.00 | 0.00 |
November | 0.312430E+09 | -194310552.5 | 0.00 | 0.00 | 720.00 | 0.00 | -118119024.1 | 58.98 | 0.00 | 0.00 |
December | 0.328162E+09 | -204794291.8 | 0.00 | 0.00 | 744.00 | 0.00 | -123367524.7 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.377699E+10 | -.238752E+10 | 8760.00 | -.138947E+10 | 58.99 | |||||
Minimum of Months | 0.295424E+09 | -217875759.8 | 0.00 | 0.00 | 672.00 | 0.00 | -123367524.7 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.340253E+09 | -186372886.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109050837.0 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.333462E+09 | -210100773.5 | 0.00 | 0.00 | 744.00 | 0.00 | -123361558.7 | 58.99 | 0.00 | 0.00 |
February | 0.303723E+09 | -192212863.2 | 0.00 | 0.00 | 672.00 | 0.00 | -111509979.8 | 58.99 | 0.00 | 0.00 |
March | 0.340724E+09 | -217872966.4 | 0.00 | 0.00 | 744.00 | 0.00 | -122850869.6 | 58.99 | 0.00 | 0.00 |
April | 0.315872E+09 | -201202104.8 | 0.00 | 0.00 | 720.00 | 0.00 | -114670033.2 | 58.99 | 0.00 | 0.00 |
May | 0.322053E+09 | -204360520.8 | 0.00 | 0.00 | 744.00 | 0.00 | -117692621.2 | 58.99 | 0.00 | 0.00 |
June | 0.304726E+09 | -195098579.2 | 0.00 | 0.00 | 720.00 | 0.00 | -109627006.7 | 58.99 | 0.00 | 0.00 |
July | 0.302167E+09 | -189795478.0 | 0.00 | 0.00 | 744.00 | 0.00 | -112371232.0 | 58.99 | 0.00 | 0.00 |
August | 0.308539E+09 | -196438424.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112100758.1 | 58.99 | 0.00 | 0.00 |
September | 0.295607E+09 | -186380263.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109226393.4 | 58.99 | 0.00 | 0.00 |
October | 0.313646E+09 | -194966248.0 | 0.00 | 0.00 | 744.00 | 0.00 | -118679920.2 | 59.00 | 0.00 | 0.00 |
November | 0.312962E+09 | -194264388.8 | 0.00 | 0.00 | 720.00 | 0.00 | -118697851.9 | 59.00 | 0.00 | 0.00 |
December | 0.328624E+09 | -204776757.8 | 0.00 | 0.00 | 744.00 | 0.00 | -123847337.2 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.378210E+10 | -.238747E+10 | 8760.00 | -.139464E+10 | 58.99 | |||||
Minimum of Months | 0.295607E+09 | -217872966.4 | 0.00 | 0.00 | 672.00 | 0.00 | -123847337.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.340724E+09 | -186380263.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109226393.4 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.323317E+09 | -198567763.5 | 0.00 | 0.00 | 744.00 | 0.00 | -124749354.8 | 59.00 | 0.00 | 0.00 |
February | 0.294477E+09 | -181783720.9 | 0.00 | 0.00 | 672.00 | 0.00 | -112693045.9 | 58.98 | 0.00 | 0.00 |
March | 0.330308E+09 | -206164883.2 | 0.00 | 0.00 | 744.00 | 0.00 | -124143162.3 | 58.99 | 0.00 | 0.00 |
April | 0.307385E+09 | -190392164.0 | 0.00 | 0.00 | 720.00 | 0.00 | -116992863.7 | 58.99 | 0.00 | 0.00 |
May | 0.313413E+09 | -193259300.0 | 0.00 | 0.00 | 744.00 | 0.00 | -120153861.3 | 58.99 | 0.00 | 0.00 |
June | 0.296094E+09 | -184608265.8 | 0.00 | 0.00 | 720.00 | 0.00 | -111485890.4 | 58.99 | 0.00 | 0.00 |
July | 0.293118E+09 | -179497449.6 | 0.00 | 0.00 | 744.00 | 0.00 | -113620192.2 | 58.99 | 0.00 | 0.00 |
August | 0.298877E+09 | -185922310.6 | 0.00 | 0.00 | 744.00 | 0.00 | -112954603.1 | 58.97 | 0.00 | 0.00 |
September | 0.286871E+09 | -176384196.8 | 0.00 | 0.00 | 720.00 | 0.00 | -110486905.2 | 58.99 | 0.00 | 0.00 |
October | 0.305381E+09 | -184284744.5 | 0.00 | 0.00 | 744.00 | 0.00 | -121095814.2 | 58.99 | 0.00 | 0.00 |
November | 0.303468E+09 | -183502295.6 | 0.00 | 0.00 | 720.00 | 0.00 | -119965337.8 | 58.99 | 0.00 | 0.00 |
December | 0.318998E+09 | -193687577.9 | 0.00 | 0.00 | 744.00 | 0.00 | -125310618.7 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.367171E+10 | -.225805E+10 | 8760.00 | -.141365E+10 | 58.99 | |||||
Minimum of Months | 0.286871E+09 | -206164883.2 | 0.00 | 0.00 | 672.00 | 0.00 | -125310618.7 | 58.97 | 0.00 | 0.00 |
Maximum of Months | 0.330308E+09 | -176384196.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110486905.2 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.323368E+09 | -198568692.3 | 0.00 | 0.00 | 744.00 | 0.00 | -124799597.8 | 59.00 | 0.00 | 0.00 |
February | 0.294515E+09 | -181777391.7 | 0.00 | 0.00 | 672.00 | 0.00 | -112737857.6 | 58.99 | 0.00 | 0.00 |
March | 0.330365E+09 | -206170847.3 | 0.00 | 0.00 | 744.00 | 0.00 | -124193845.3 | 58.99 | 0.00 | 0.00 |
April | 0.307721E+09 | -190389774.7 | 0.00 | 0.00 | 720.00 | 0.00 | -117330829.4 | 58.99 | 0.00 | 0.00 |
May | 0.313885E+09 | -193260413.1 | 0.00 | 0.00 | 744.00 | 0.00 | -120624301.4 | 58.99 | 0.00 | 0.00 |
June | 0.296775E+09 | -184605276.5 | 0.00 | 0.00 | 720.00 | 0.00 | -112169470.9 | 58.99 | 0.00 | 0.00 |
July | 0.293597E+09 | -179480805.2 | 0.00 | 0.00 | 744.00 | 0.00 | -114116398.4 | 59.00 | 0.00 | 0.00 |
August | 0.299182E+09 | -185898920.5 | 0.00 | 0.00 | 744.00 | 0.00 | -113282746.0 | 58.98 | 0.00 | 0.00 |
September | 0.287426E+09 | -176375575.1 | 0.00 | 0.00 | 720.00 | 0.00 | -111050088.5 | 58.99 | 0.00 | 0.00 |
October | 0.305780E+09 | -184270747.2 | 0.00 | 0.00 | 744.00 | 0.00 | -121509383.2 | 59.00 | 0.00 | 0.00 |
November | 0.303535E+09 | -183498585.1 | 0.00 | 0.00 | 720.00 | 0.00 | -120036118.7 | 58.99 | 0.00 | 0.00 |
December | 0.319011E+09 | -193690895.1 | 0.00 | 0.00 | 744.00 | 0.00 | -125320199.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.367516E+10 | -.225799E+10 | 8760.00 | -.141717E+10 | 58.99 | |||||
Minimum of Months | 0.287426E+09 | -206170847.3 | 0.00 | 0.00 | 672.00 | 0.00 | -125320199.1 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.330365E+09 | -176375575.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111050088.5 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.323484E+09 | -198574834.8 | 0.00 | 0.00 | 744.00 | 0.00 | -124908832.2 | 58.99 | 0.00 | 0.00 |
February | 0.294626E+09 | -181751858.2 | 0.00 | 0.00 | 672.00 | 0.00 | -112874038.4 | 59.00 | 0.00 | 0.00 |
March | 0.330472E+09 | -206166771.5 | 0.00 | 0.00 | 744.00 | 0.00 | -124304774.0 | 58.99 | 0.00 | 0.00 |
April | 0.307950E+09 | -190388840.0 | 0.00 | 0.00 | 720.00 | 0.00 | -117561421.8 | 59.00 | 0.00 | 0.00 |
May | 0.314178E+09 | -193255791.5 | 0.00 | 0.00 | 744.00 | 0.00 | -120922670.0 | 58.99 | 0.00 | 0.00 |
June | 0.297191E+09 | -184612463.0 | 0.00 | 0.00 | 720.00 | 0.00 | -112578498.1 | 58.99 | 0.00 | 0.00 |
July | 0.293874E+09 | -179491833.4 | 0.00 | 0.00 | 744.00 | 0.00 | -114382337.3 | 58.99 | 0.00 | 0.00 |
August | 0.299335E+09 | -185898673.0 | 0.00 | 0.00 | 744.00 | 0.00 | -113436276.4 | 58.98 | 0.00 | 0.00 |
September | 0.287718E+09 | -176371271.8 | 0.00 | 0.00 | 720.00 | 0.00 | -111346285.1 | 58.99 | 0.00 | 0.00 |
October | 0.306062E+09 | -184280296.5 | 0.00 | 0.00 | 744.00 | 0.00 | -121781661.3 | 58.99 | 0.00 | 0.00 |
November | 0.303638E+09 | -183496803.4 | 0.00 | 0.00 | 720.00 | 0.00 | -120140953.0 | 59.00 | 0.00 | 0.00 |
December | 0.319117E+09 | -193690356.5 | 0.00 | 0.00 | 744.00 | 0.00 | -125426951.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.367764E+10 | -.225798E+10 | 8760.00 | -.141966E+10 | 58.99 | |||||
Minimum of Months | 0.287718E+09 | -206166771.5 | 0.00 | 0.00 | 672.00 | 0.00 | -125426951.8 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.330472E+09 | -176371271.8 | 0.00 | 0.00 | 744.00 | 0.00 | -111346285.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 195.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 217.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 215.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 359.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 417.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 410.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 396.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 234.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 171.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3515.67 | ||||||||||
Minimum of Months | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.100974E+11 | 54916.77 | 02-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.835579E+10 | 54916.77 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.677550E+10 | 54916.77 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.844467E+09 | 54916.77 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.444927E+09 | 54916.77 | 05-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.769819E+09 | 53879.13 | 23-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.539274E+10 | 54916.77 | 02-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.114056E+11 | 54916.77 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.440862E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.114056E+11 | 54916.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.304341E+10 | 29533.43 | 09-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.222489E+10 | 29533.43 | 16-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.168489E+10 | 24843.78 | 04-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 79896446.55 | 4850.95 | 10-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11144359.39 | 1031.20 | 05-MAY-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 59642360.93 | 1620.02 | 27-OCT-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.136915E+10 | 29533.43 | 28-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.350842E+10 | 29533.43 | 08-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.119815E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.350842E+10 | 29533.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.414486E+10 | 29413.92 | 08-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.322665E+10 | 29413.92 | 13-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.255743E+10 | 21760.71 | 04-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.239663E+09 | 5019.41 | 12-APR-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 48586745.14 | 3383.79 | 06-MAY-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.250033E+09 | 4219.08 | 23-OCT-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.216494E+10 | 29413.92 | 20-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.465100E+10 | 29413.92 | 03-DEC-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.172832E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.465100E+10 | 29413.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.446224E+10 | 29945.11 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.349592E+10 | 29945.11 | 12-FEB-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.283351E+10 | 26902.96 | 06-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.335115E+09 | 7676.10 | 02-APR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 93840500.61 | 5357.74 | 06-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.364790E+09 | 7458.03 | 23-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.244898E+10 | 29945.11 | 20-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.494942E+10 | 29945.11 | 03-DEC-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189838E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.494942E+10 | 29945.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.487370E+10 | 29257.25 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.386287E+10 | 29257.25 | 12-FEB-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.321637E+10 | 29257.25 | 04-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.471847E+09 | 10849.11 | 02-APR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.195239E+09 | 8502.16 | 06-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.530461E+09 | 11017.94 | 23-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.280625E+10 | 29257.25 | 19-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.536958E+10 | 29257.25 | 03-DEC-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.213263E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.536958E+10 | 29257.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.107193E+11 | 53646.77 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.868263E+10 | 53646.77 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.772210E+10 | 53646.77 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.160106E+10 | 53646.77 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.999804E+09 | 53646.77 | 05-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 8721491.84 | 3971.43 | 07-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.196012E+10 | 53646.77 | 15-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.690757E+10 | 53646.77 | 02-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.115816E+11 | 53646.77 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.501829E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.115816E+11 | 53646.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.621775E+10 | 27555.17 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.507883E+10 | 27555.17 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.458330E+10 | 27555.17 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.120967E+10 | 27555.17 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.832452E+09 | 27555.17 | 05-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 28040848.52 | 8864.52 | 08-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1124562.46 | 684.88 | 05-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 235310.48 | 772.66 | 20-SEP-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.140566E+10 | 27555.17 | 15-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.411397E+10 | 27555.17 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.667257E+10 | 27555.17 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.301436E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.667257E+10 | 27555.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.633398E+10 | 27368.10 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.518685E+10 | 27368.10 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.470302E+10 | 27368.10 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.130411E+10 | 27368.10 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.931439E+09 | 27368.10 | 05-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 44464636.37 | 13679.38 | 08-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 2946445.23 | 1769.05 | 05-JUL-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 3168564.73 | 1069.43 | 20-SEP-07:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.150759E+10 | 27368.10 | 15-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.422256E+10 | 27368.10 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.677933E+10 | 27368.10 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.310195E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.677933E+10 | 27368.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.672900E+10 | 27000.32 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.556543E+10 | 27000.32 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.510990E+10 | 27000.32 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.156313E+10 | 27000.32 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.119760E+10 | 27000.32 | 05-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 88872440.11 | 24016.08 | 08-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 12869839.24 | 6744.69 | 05-JUL-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 19483961.59 | 2453.25 | 20-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.176675E+10 | 27000.32 | 14-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.456041E+10 | 27000.32 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.716388E+10 | 27000.32 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.337773E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.716388E+10 | 27000.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.814477E+10 | 26326.54 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.690774E+10 | 26326.54 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.652727E+10 | 26326.54 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.236045E+10 | 26326.54 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207689E+10 | 26326.54 | 02-MAY-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.299252E+09 | 26326.54 | 06-JUN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 61466245.77 | 26326.54 | 03-JUL-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.120985E+09 | 14615.08 | 09-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.256907E+10 | 26326.54 | 03-OCT-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.567403E+10 | 26326.54 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.863291E+10 | 26326.54 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.433748E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.863291E+10 | 26326.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.461656E+09 | 0.460275E+09 | 13375.51 | 30-APR-16:05 | 13375.51 | 0.00 |
May | 0.00 | 0.00 | 0.255980E+09 | 0.227672E+09 | 12019.36 | 22-MAY-15:00 | 11200.50 | 0.00 |
June | 0.00 | 0.00 | 0.187834E+10 | 0.159843E+10 | 18066.28 | 13-JUN-17:00 | 16730.72 | 0.00 |
July | 0.00 | 0.00 | 0.300006E+10 | 0.265074E+10 | 26569.93 | 22-JUL-07:03 | 24024.22 | 0.00 |
August | 0.00 | 0.00 | 0.264089E+10 | 0.225718E+10 | 16415.29 | 14-AUG-17:00 | 16415.29 | 0.00 |
September | 0.00 | 0.00 | 0.168605E+10 | 0.145487E+10 | 13509.02 | 13-SEP-14:00 | 11677.53 | 0.00 |
October | 0.00 | 0.00 | 558849.92 | 558025.00 | 618.31 | 07-OCT-15:00 | 618.31 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.992354E+10 | 0.864973E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.300006E+10 | 0.265074E+10 | 26569.93 | 24024.22 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 24639.19 | 24639.19 | 20.99 | 18-JAN-23:10 | 20.99 | 0.00 |
February | 0.00 | 0.00 | 12027.57 | 12027.57 | 20.05 | 11-FEB-24:00 | 20.05 | 0.00 |
March | 0.00 | 0.00 | 293054.70 | 268981.06 | 167.04 | 25-MAR-23:20 | 158.90 | 0.00 |
April | 0.00 | 0.00 | 0.325813E+09 | 0.322738E+09 | 16666.44 | 30-APR-19:02 | 16666.44 | 0.00 |
May | 0.00 | 0.00 | 0.224710E+09 | 0.202100E+09 | 16692.82 | 21-MAY-18:52 | 15167.53 | 0.00 |
June | 0.00 | 0.00 | 0.116714E+10 | 0.993270E+09 | 18390.49 | 25-JUN-18:00 | 10924.49 | 0.00 |
July | 0.00 | 0.00 | 0.191468E+10 | 0.166909E+10 | 17683.10 | 23-JUL-17:02 | 12982.11 | 0.00 |
August | 0.00 | 0.00 | 0.179920E+10 | 0.152594E+10 | 17185.14 | 13-AUG-17:02 | 13233.24 | 0.00 |
September | 0.00 | 0.00 | 0.109527E+10 | 0.942234E+09 | 17567.25 | 10-SEP-17:02 | 11895.03 | 0.00 |
October | 0.00 | 0.00 | 14965321.12 | 14505511.33 | 16333.39 | 04-OCT-20:01 | 16333.39 | 0.00 |
November | 0.00 | 0.00 | 711362.14 | 653610.13 | 339.47 | 08-NOV-23:40 | 290.86 | 0.00 |
December | 0.00 | 0.00 | 23541.82 | 23541.82 | 18.15 | 24-DEC-23:00 | 18.15 | 0.00 |
Annual Sum or Average | 0.654285E+10 | 0.567085E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 12027.57 | 12027.57 | 18.15 | 18.15 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.191468E+10 | 0.166909E+10 | 18390.49 | 16666.44 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.160576E+09 | 0.159808E+09 | 7135.48 | 30-APR-15:00 | 7135.48 | 0.00 |
May | 0.00 | 0.00 | 0.131484E+09 | 0.116325E+09 | 6515.30 | 22-MAY-15:00 | 6084.97 | 0.00 |
June | 0.00 | 0.00 | 0.926944E+09 | 0.798808E+09 | 11027.11 | 27-JUN-06:02 | 6079.50 | 0.00 |
July | 0.00 | 0.00 | 0.136231E+10 | 0.120916E+10 | 17247.23 | 18-JUL-06:02 | 11255.51 | 0.00 |
August | 0.00 | 0.00 | 0.141450E+10 | 0.120351E+10 | 9763.26 | 06-AUG-07:02 | 6318.09 | 0.00 |
September | 0.00 | 0.00 | 0.883796E+09 | 0.769210E+09 | 10618.10 | 02-SEP-06:02 | 6884.14 | 0.00 |
October | 0.00 | 0.00 | 1029368.85 | 1029216.55 | 605.51 | 07-OCT-15:00 | 605.51 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.488063E+10 | 0.425785E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.141450E+10 | 0.120916E+10 | 17247.23 | 11255.51 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.152638E+09 | 0.151952E+09 | 7037.49 | 30-APR-15:00 | 7037.49 | 0.00 |
May | 0.00 | 0.00 | 0.114725E+09 | 0.102002E+09 | 6226.15 | 22-MAY-15:00 | 5811.61 | 0.00 |
June | 0.00 | 0.00 | 0.902480E+09 | 0.777898E+09 | 9607.58 | 27-JUN-06:02 | 5291.30 | 0.00 |
July | 0.00 | 0.00 | 0.132996E+10 | 0.118220E+10 | 17130.88 | 23-JUL-07:03 | 13684.00 | 0.00 |
August | 0.00 | 0.00 | 0.137078E+10 | 0.116758E+10 | 8569.34 | 14-AUG-17:00 | 8569.34 | 0.00 |
September | 0.00 | 0.00 | 0.851024E+09 | 0.741558E+09 | 8399.06 | 02-SEP-06:02 | 5439.35 | 0.00 |
October | 0.00 | 0.00 | 453300.48 | 453283.98 | 434.74 | 07-OCT-15:00 | 434.74 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.472207E+10 | 0.412364E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.137078E+10 | 0.118220E+10 | 17130.88 | 13684.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.138570E+09 | 0.138026E+09 | 6802.57 | 30-APR-15:00 | 6802.57 | 0.00 |
May | 0.00 | 0.00 | 92831955.98 | 83252027.74 | 5803.32 | 22-MAY-15:00 | 5412.86 | 0.00 |
June | 0.00 | 0.00 | 0.848267E+09 | 0.731644E+09 | 9279.04 | 13-JUN-16:30 | 8503.40 | 0.00 |
July | 0.00 | 0.00 | 0.124771E+10 | 0.111314E+10 | 16978.38 | 23-JUL-07:03 | 13540.04 | 0.00 |
August | 0.00 | 0.00 | 0.126578E+10 | 0.108159E+10 | 8393.61 | 14-AUG-17:00 | 8393.61 | 0.00 |
September | 0.00 | 0.00 | 0.783993E+09 | 0.684709E+09 | 7174.97 | 13-SEP-14:00 | 6214.01 | 0.00 |
October | 0.00 | 0.00 | 166954.86 | 166953.72 | 129.26 | 07-OCT-15:00 | 129.26 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.437732E+10 | 0.383253E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.126578E+10 | 0.111314E+10 | 16978.38 | 13540.04 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.189388E+09 | 0.188830E+09 | 11419.65 | 30-APR-15:00 | 11419.65 | 0.00 |
May | 0.00 | 0.00 | 0.106768E+09 | 97369164.50 | 9292.95 | 22-MAY-15:00 | 8571.63 | 0.00 |
June | 0.00 | 0.00 | 0.129839E+10 | 0.111701E+10 | 15768.31 | 13-JUN-16:20 | 14244.64 | 0.00 |
July | 0.00 | 0.00 | 0.185911E+10 | 0.167057E+10 | 22356.87 | 22-JUL-07:03 | 19972.39 | 0.00 |
August | 0.00 | 0.00 | 0.182073E+10 | 0.156688E+10 | 14230.02 | 14-AUG-17:00 | 14230.02 | 0.00 |
September | 0.00 | 0.00 | 0.112063E+10 | 0.980462E+09 | 12078.17 | 13-SEP-14:10 | 10420.75 | 0.00 |
October | 0.00 | 0.00 | 11819.80 | 11819.80 | 2.43 | 07-OCT-13:00 | 2.43 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.639504E+10 | 0.562113E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.185911E+10 | 0.167057E+10 | 22356.87 | 19972.39 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.234445E+09 | 0.234429E+09 | 5819.63 | 30-APR-15:00 | 5819.63 | 0.00 |
May | 0.00 | 0.00 | 0.214090E+09 | 0.191533E+09 | 4657.99 | 22-MAY-15:00 | 4310.42 | 0.00 |
June | 0.00 | 0.00 | 0.113675E+10 | 0.100636E+10 | 8097.51 | 13-JUN-16:30 | 7343.39 | 0.00 |
July | 0.00 | 0.00 | 0.241665E+10 | 0.213201E+10 | 11851.58 | 24-JUL-07:02 | 9108.19 | 0.00 |
August | 0.00 | 0.00 | 0.304975E+10 | 0.267561E+10 | 7367.56 | 14-AUG-17:00 | 7367.56 | 0.00 |
September | 0.00 | 0.00 | 0.147103E+10 | 0.131375E+10 | 6489.69 | 13-SEP-14:20 | 5765.53 | 0.00 |
October | 0.00 | 0.00 | 14168050.13 | 14168050.13 | 1928.38 | 07-OCT-15:00 | 1928.38 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.853687E+10 | 0.756786E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.304975E+10 | 0.267561E+10 | 11851.58 | 9108.19 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.213769E+09 | 0.213757E+09 | 5663.68 | 30-APR-15:00 | 5663.68 | 0.00 |
May | 0.00 | 0.00 | 0.189464E+09 | 0.169265E+09 | 4485.64 | 22-MAY-15:00 | 4148.59 | 0.00 |
June | 0.00 | 0.00 | 0.104564E+10 | 0.924138E+09 | 7937.98 | 13-JUN-16:30 | 7195.09 | 0.00 |
July | 0.00 | 0.00 | 0.227355E+10 | 0.200510E+10 | 10152.15 | 23-JUL-08:63 | 9528.40 | 0.00 |
August | 0.00 | 0.00 | 0.289211E+10 | 0.253542E+10 | 7249.38 | 14-AUG-17:00 | 7249.38 | 0.00 |
September | 0.00 | 0.00 | 0.135636E+10 | 0.120986E+10 | 6354.13 | 13-SEP-14:20 | 5640.80 | 0.00 |
October | 0.00 | 0.00 | 10931650.79 | 10931650.79 | 1702.17 | 07-OCT-15:00 | 1702.17 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.798183E+10 | 0.706848E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.289211E+10 | 0.253542E+10 | 10152.15 | 9528.40 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.179487E+09 | 0.179481E+09 | 5358.71 | 30-APR-15:00 | 5358.71 | 0.00 |
May | 0.00 | 0.00 | 0.148001E+09 | 0.131988E+09 | 4154.82 | 22-MAY-15:00 | 3838.40 | 0.00 |
June | 0.00 | 0.00 | 0.898561E+09 | 0.791533E+09 | 7644.54 | 13-JUN-16:30 | 6922.59 | 0.00 |
July | 0.00 | 0.00 | 0.199178E+10 | 0.175740E+10 | 8985.43 | 22-JUL-15:00 | 8985.43 | 0.00 |
August | 0.00 | 0.00 | 0.254901E+10 | 0.223186E+10 | 7002.93 | 14-AUG-17:00 | 7002.93 | 0.00 |
September | 0.00 | 0.00 | 0.116788E+10 | 0.103975E+10 | 6108.80 | 13-SEP-14:20 | 5415.49 | 0.00 |
October | 0.00 | 0.00 | 6750578.09 | 6750578.09 | 1349.39 | 07-OCT-15:00 | 1349.39 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.694146E+10 | 0.613876E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.254901E+10 | 0.223186E+10 | 8985.43 | 8985.43 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.133653E+09 | 0.133650E+09 | 4792.59 | 30-APR-15:00 | 4792.59 | 0.00 |
May | 0.00 | 0.00 | 97573146.50 | 87207488.84 | 3605.81 | 22-MAY-15:00 | 3325.51 | 0.00 |
June | 0.00 | 0.00 | 0.710206E+09 | 0.623129E+09 | 7137.65 | 13-JUN-16:30 | 6452.18 | 0.00 |
July | 0.00 | 0.00 | 0.148820E+10 | 0.132262E+10 | 8756.74 | 22-JUL-15:00 | 8756.74 | 0.00 |
August | 0.00 | 0.00 | 0.187743E+10 | 0.164189E+10 | 6513.68 | 14-AUG-17:00 | 6513.68 | 0.00 |
September | 0.00 | 0.00 | 0.896611E+09 | 0.797297E+09 | 5665.72 | 13-SEP-14:10 | 5013.27 | 0.00 |
October | 0.00 | 0.00 | 2205036.39 | 2205036.39 | 717.35 | 07-OCT-15:00 | 717.35 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.520588E+10 | 0.460800E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.187743E+10 | 0.164189E+10 | 8756.74 | 8756.74 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.372351E+10 | 0.62 | 2051.82 | 01-JAN-11:20 | 0.91 |
February | 0.336844E+10 | 0.61 | 2051.82 | 01-FEB-21:45 | 0.90 |
March | 0.373029E+10 | 0.62 | 2051.82 | 01-MAR-19:30 | 0.91 |
April | 0.361202E+10 | 0.62 | 2051.82 | 01-APR-22:20 | 0.91 |
May | 0.372282E+10 | 0.61 | 2051.82 | 03-MAY-11:40 | 0.90 |
June | 0.361202E+10 | 0.61 | 2051.82 | 01-JUN-12:50 | 0.90 |
July | 0.373020E+10 | 0.61 | 2051.82 | 01-JUL-17:00 | 0.90 |
August | 0.372282E+10 | 0.61 | 2051.82 | 01-AUG-17:50 | 0.90 |
September | 0.361940E+10 | 0.61 | 2051.82 | 01-SEP-15:40 | 0.90 |
October | 0.372282E+10 | 0.61 | 2051.82 | 01-OCT-18:20 | 0.90 |
November | 0.359754E+10 | 0.61 | 2051.82 | 01-NOV-18:00 | 0.90 |
December | 0.373861E+10 | 0.62 | 2051.82 | 01-DEC-08:08 | 0.91 |
Annual Sum or Average | 0.439005E+11 | 0.61 | |||
Minimum of Months | 0.336844E+10 | 0.61 | 2051.82 | 0.90 | |
Maximum of Months | 0.373861E+10 | 0.62 | 2051.82 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.161809E+10 | 0.52 | 1189.83 | 01-JAN-13:10 | 0.94 |
February | 0.146226E+10 | 0.50 | 1189.83 | 01-FEB-10:00 | 0.94 |
March | 0.164836E+10 | 0.54 | 1189.83 | 01-MAR-09:30 | 0.94 |
April | 0.171312E+10 | 0.62 | 1189.83 | 08-APR-11:30 | 0.94 |
May | 0.183662E+10 | 0.63 | 1189.83 | 04-MAY-16:40 | 0.94 |
June | 0.203575E+10 | 0.64 | 1189.83 | 02-JUN-16:20 | 0.94 |
July | 0.210343E+10 | 0.63 | 1189.83 | 01-JUL-10:30 | 0.94 |
August | 0.212456E+10 | 0.63 | 1189.83 | 01-AUG-14:40 | 0.94 |
September | 0.204778E+10 | 0.64 | 1189.83 | 01-SEP-12:40 | 0.94 |
October | 0.174763E+10 | 0.62 | 1189.83 | 01-OCT-12:00 | 0.94 |
November | 0.158052E+10 | 0.55 | 1189.83 | 01-NOV-15:00 | 0.94 |
December | 0.160655E+10 | 0.48 | 1189.83 | 01-DEC-14:10 | 0.94 |
Annual Sum or Average | 0.215247E+11 | 0.58 | |||
Minimum of Months | 0.146226E+10 | 0.48 | 1189.83 | 0.94 | |
Maximum of Months | 0.212456E+10 | 0.64 | 1189.83 | 0.94 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.172249E+10 | 0.51 | 1190.22 | 02-JAN-11:20 | 0.95 |
February | 0.155967E+10 | 0.51 | 1190.22 | 01-FEB-15:20 | 0.94 |
March | 0.175677E+10 | 0.52 | 1190.22 | 03-MAR-09:20 | 0.94 |
April | 0.167107E+10 | 0.51 | 1190.22 | 02-APR-12:10 | 0.94 |
May | 0.173963E+10 | 0.51 | 1190.22 | 05-MAY-15:50 | 0.94 |
June | 0.169678E+10 | 0.52 | 1190.22 | 02-JUN-15:30 | 0.94 |
July | 0.171392E+10 | 0.50 | 1190.22 | 11-JUL-08:20 | 0.94 |
August | 0.175677E+10 | 0.52 | 1190.22 | 04-AUG-11:30 | 0.94 |
September | 0.167107E+10 | 0.51 | 1190.22 | 01-SEP-18:40 | 0.94 |
October | 0.172249E+10 | 0.51 | 1190.22 | 06-OCT-14:00 | 0.94 |
November | 0.167107E+10 | 0.51 | 1190.22 | 02-NOV-14:00 | 0.94 |
December | 0.171392E+10 | 0.51 | 1190.22 | 01-DEC-08:08 | 0.94 |
Annual Sum or Average | 0.203957E+11 | 0.51 | |||
Minimum of Months | 0.155967E+10 | 0.50 | 1190.22 | 0.94 | |
Maximum of Months | 0.175677E+10 | 0.52 | 1190.22 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.172793E+10 | 0.51 | 1193.98 | 01-JAN-09:05 | 0.95 |
February | 0.156459E+10 | 0.51 | 1193.98 | 01-FEB-08:02 | 0.94 |
March | 0.176232E+10 | 0.52 | 1193.98 | 01-MAR-08:03 | 0.94 |
April | 0.167635E+10 | 0.51 | 1193.98 | 01-APR-06:30 | 0.95 |
May | 0.174512E+10 | 0.51 | 1193.98 | 03-MAY-12:20 | 0.94 |
June | 0.170214E+10 | 0.52 | 1193.98 | 01-JUN-13:00 | 0.94 |
July | 0.171933E+10 | 0.50 | 1193.98 | 01-JUL-13:20 | 0.94 |
August | 0.176232E+10 | 0.52 | 1193.98 | 01-AUG-10:10 | 0.94 |
September | 0.167635E+10 | 0.51 | 1193.98 | 01-SEP-11:10 | 0.94 |
October | 0.172793E+10 | 0.51 | 1193.98 | 02-OCT-17:20 | 0.94 |
November | 0.167635E+10 | 0.51 | 1193.98 | 01-NOV-08:10 | 0.94 |
December | 0.171933E+10 | 0.51 | 1193.98 | 01-DEC-08:61 | 0.94 |
Annual Sum or Average | 0.204601E+11 | 0.51 | |||
Minimum of Months | 0.156459E+10 | 0.50 | 1193.98 | 0.94 | |
Maximum of Months | 0.176232E+10 | 0.52 | 1193.98 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.171307E+10 | 0.51 | 1183.71 | 02-JAN-20:10 | 0.95 |
February | 0.155114E+10 | 0.51 | 1183.71 | 01-FEB-08:30 | 0.94 |
March | 0.174716E+10 | 0.52 | 1183.71 | 01-MAR-09:50 | 0.94 |
April | 0.166193E+10 | 0.51 | 1183.71 | 01-APR-07:01 | 0.95 |
May | 0.173011E+10 | 0.51 | 1183.71 | 04-MAY-07:40 | 0.94 |
June | 0.168750E+10 | 0.52 | 1183.71 | 09-JUN-10:00 | 0.94 |
July | 0.170455E+10 | 0.50 | 1183.71 | 01-JUL-16:30 | 0.94 |
August | 0.174716E+10 | 0.52 | 1183.71 | 01-AUG-17:00 | 0.94 |
September | 0.166193E+10 | 0.51 | 1183.71 | 01-SEP-06:08 | 0.94 |
October | 0.171307E+10 | 0.51 | 1183.71 | 03-OCT-10:50 | 0.94 |
November | 0.166193E+10 | 0.51 | 1183.71 | 01-NOV-09:00 | 0.94 |
December | 0.170455E+10 | 0.51 | 1183.71 | 01-DEC-20:20 | 0.94 |
Annual Sum or Average | 0.202841E+11 | 0.51 | |||
Minimum of Months | 0.155114E+10 | 0.50 | 1183.71 | 0.94 | |
Maximum of Months | 0.174716E+10 | 0.52 | 1183.71 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.265833E+10 | 0.45 | 1990.37 | 02-JAN-08:20 | 0.91 |
February | 0.240755E+10 | 0.45 | 1990.37 | 01-FEB-16:50 | 0.90 |
March | 0.271566E+10 | 0.46 | 1990.37 | 02-MAR-10:40 | 0.91 |
April | 0.257952E+10 | 0.45 | 1990.37 | 05-APR-10:00 | 0.91 |
May | 0.268700E+10 | 0.46 | 1990.37 | 03-MAY-20:00 | 0.90 |
June | 0.262251E+10 | 0.46 | 1990.37 | 09-JUN-14:50 | 0.90 |
July | 0.264400E+10 | 0.45 | 1990.37 | 06-JUL-11:50 | 0.90 |
August | 0.271566E+10 | 0.46 | 1990.37 | 01-AUG-10:50 | 0.90 |
September | 0.257952E+10 | 0.45 | 1990.37 | 01-SEP-10:20 | 0.90 |
October | 0.265833E+10 | 0.45 | 1990.37 | 10-OCT-09:00 | 0.90 |
November | 0.257952E+10 | 0.45 | 1990.37 | 01-NOV-11:40 | 0.90 |
December | 0.264400E+10 | 0.45 | 1990.37 | 03-DEC-12:30 | 0.91 |
Annual Sum or Average | 0.314916E+11 | 0.45 | |||
Minimum of Months | 0.240755E+10 | 0.45 | 1990.37 | 0.90 | |
Maximum of Months | 0.271566E+10 | 0.46 | 1990.37 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.143842E+10 | 0.47 | 1076.99 | 23-JAN-10:40 | 0.94 |
February | 0.130272E+10 | 0.47 | 1076.99 | 01-FEB-08:02 | 0.94 |
March | 0.146944E+10 | 0.48 | 1076.99 | 01-MAR-08:10 | 0.94 |
April | 0.139577E+10 | 0.47 | 1076.99 | 12-APR-15:00 | 0.95 |
May | 0.145393E+10 | 0.47 | 1076.99 | 06-MAY-12:20 | 0.94 |
June | 0.141904E+10 | 0.48 | 1076.99 | 08-JUN-08:15 | 0.94 |
July | 0.143067E+10 | 0.47 | 1076.99 | 05-JUL-08:00 | 0.94 |
August | 0.146944E+10 | 0.48 | 1076.99 | 01-AUG-09:30 | 0.94 |
September | 0.139577E+10 | 0.47 | 1076.99 | 05-SEP-12:20 | 0.94 |
October | 0.143842E+10 | 0.47 | 1076.99 | 10-OCT-11:30 | 0.94 |
November | 0.139577E+10 | 0.47 | 1076.99 | 04-NOV-10:50 | 0.94 |
December | 0.143067E+10 | 0.47 | 1076.99 | 01-DEC-08:05 | 0.94 |
Annual Sum or Average | 0.170401E+11 | 0.47 | |||
Minimum of Months | 0.130272E+10 | 0.47 | 1076.99 | 0.94 | |
Maximum of Months | 0.146944E+10 | 0.48 | 1076.99 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.142676E+10 | 0.47 | 1068.25 | 01-JAN-09:15 | 0.95 |
February | 0.129216E+10 | 0.47 | 1068.25 | 01-FEB-08:15 | 0.94 |
March | 0.145752E+10 | 0.48 | 1068.25 | 01-MAR-08:30 | 0.94 |
April | 0.138446E+10 | 0.47 | 1068.25 | 01-APR-07:04 | 0.95 |
May | 0.144214E+10 | 0.47 | 1068.25 | 01-MAY-13:00 | 0.94 |
June | 0.140753E+10 | 0.48 | 1068.25 | 22-JUN-19:30 | 0.94 |
July | 0.141907E+10 | 0.47 | 1068.25 | 05-JUL-07:15 | 0.94 |
August | 0.145752E+10 | 0.48 | 1068.25 | 01-AUG-09:20 | 0.94 |
September | 0.138446E+10 | 0.47 | 1068.25 | 01-SEP-11:20 | 0.94 |
October | 0.142676E+10 | 0.47 | 1068.25 | 02-OCT-07:10 | 0.94 |
November | 0.138446E+10 | 0.47 | 1068.25 | 01-NOV-07:07 | 0.94 |
December | 0.141907E+10 | 0.47 | 1068.25 | 01-DEC-08:05 | 0.94 |
Annual Sum or Average | 0.169019E+11 | 0.47 | |||
Minimum of Months | 0.129216E+10 | 0.47 | 1068.25 | 0.94 | |
Maximum of Months | 0.145752E+10 | 0.48 | 1068.25 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.140496E+10 | 0.47 | 1051.93 | 15-JAN-11:10 | 0.94 |
February | 0.127241E+10 | 0.47 | 1051.93 | 07-FEB-15:20 | 0.94 |
March | 0.143525E+10 | 0.48 | 1051.93 | 02-MAR-17:50 | 0.94 |
April | 0.136330E+10 | 0.47 | 1051.93 | 04-APR-19:10 | 0.94 |
May | 0.142010E+10 | 0.47 | 1051.93 | 02-MAY-08:30 | 0.94 |
June | 0.138602E+10 | 0.48 | 1051.93 | 01-JUN-07:10 | 0.94 |
July | 0.139738E+10 | 0.47 | 1051.93 | 05-JUL-07:05 | 0.94 |
August | 0.143525E+10 | 0.48 | 1051.93 | 08-AUG-15:20 | 0.93 |
September | 0.136330E+10 | 0.47 | 1051.93 | 21-SEP-17:40 | 0.94 |
October | 0.140496E+10 | 0.47 | 1051.93 | 10-OCT-08:20 | 0.94 |
November | 0.136330E+10 | 0.47 | 1051.93 | 02-NOV-18:20 | 0.94 |
December | 0.139738E+10 | 0.47 | 1051.93 | 07-DEC-08:50 | 0.94 |
Annual Sum or Average | 0.166436E+11 | 0.47 | |||
Minimum of Months | 0.127241E+10 | 0.47 | 1051.93 | 0.93 | |
Maximum of Months | 0.143525E+10 | 0.48 | 1051.93 | 0.94 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.137529E+10 | 0.47 | 1029.71 | 01-JAN-11:00 | 0.94 |
February | 0.124554E+10 | 0.47 | 1029.71 | 01-FEB-08:40 | 0.94 |
March | 0.140494E+10 | 0.48 | 1029.71 | 01-MAR-13:50 | 0.94 |
April | 0.133451E+10 | 0.47 | 1029.71 | 01-APR-07:07 | 0.95 |
May | 0.139011E+10 | 0.47 | 1029.71 | 01-MAY-07:13 | 0.94 |
June | 0.135675E+10 | 0.48 | 1029.71 | 01-JUN-09:00 | 0.94 |
July | 0.136787E+10 | 0.47 | 1029.71 | 01-JUL-07:50 | 0.94 |
August | 0.140494E+10 | 0.48 | 1029.71 | 01-AUG-10:10 | 0.94 |
September | 0.133451E+10 | 0.47 | 1029.71 | 01-SEP-12:20 | 0.94 |
October | 0.137529E+10 | 0.47 | 1029.71 | 01-OCT-08:10 | 0.94 |
November | 0.133451E+10 | 0.47 | 1029.71 | 01-NOV-07:06 | 0.94 |
December | 0.136787E+10 | 0.47 | 1029.71 | 01-DEC-13:10 | 0.94 |
Annual Sum or Average | 0.162921E+11 | 0.47 | |||
Minimum of Months | 0.124554E+10 | 0.47 | 1029.71 | 0.94 | |
Maximum of Months | 0.140494E+10 | 0.48 | 1029.71 | 0.95 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.21 | 1.50 |
February | 0.51 | 1.34 |
March | 0.08 | 1.50 |
April | 0.08 | 1.50 |
May | 0.28 | 1.50 |
June | 0.00 | 0.00 |
July | 0.17 | 1.50 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.22 | 1.50 |
November | 0.00 | 0.00 |
December | 0.26 | 1.50 |
Annual Sum or Average | 1.82 | 1.45 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.51 | 1.50 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.86 | 5.45 |
February | 2.14 | 4.99 |
March | 3.03 | 5.09 |
April | 1.34 | 5.92 |
May | 0.50 | 4.58 |
June | 0.97 | 7.12 |
July | 1.28 | 6.99 |
August | 1.08 | 7.27 |
September | 0.25 | 9.00 |
October | 1.24 | 4.89 |
November | 1.86 | 5.33 |
December | 2.03 | 4.72 |
Annual Sum or Average | 17.57 | 5.57 |
Minimum of Months | 0.25 | 4.58 |
Maximum of Months | 3.03 | 9.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.08 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 1.04 | 0.66 |
May | 1.47 | 0.62 |
June | 0.21 | 0.75 |
July | 0.46 | 0.48 |
August | 0.26 | 0.75 |
September | 0.17 | 0.75 |
October | 1.65 | 0.71 |
November | 0.22 | 0.75 |
December | 0.00 | 0.00 |
Annual Sum or Average | 5.57 | 0.65 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.65 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.17 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 1.04 | 0.66 |
May | 1.39 | 0.66 |
June | 0.21 | 0.75 |
July | 0.54 | 0.52 |
August | 0.26 | 0.75 |
September | 0.17 | 0.75 |
October | 1.43 | 0.71 |
November | 0.22 | 0.47 |
December | 0.00 | 0.00 |
Annual Sum or Average | 5.43 | 0.64 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.43 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.17 | 0.00 |
February | 0.08 | 0.00 |
March | 0.00 | 0.00 |
April | 0.67 | 0.66 |
May | 0.81 | 0.67 |
June | 0.12 | 0.75 |
July | 0.54 | 0.52 |
August | 0.18 | 0.75 |
September | 0.17 | 0.75 |
October | 1.29 | 0.70 |
November | 0.22 | 0.19 |
December | 0.08 | 0.00 |
Annual Sum or Average | 4.33 | 0.59 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.29 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.04 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.53 | 1.74 |
June | 0.00 | 0.00 |
July | 0.38 | 1.83 |
August | 0.00 | 0.00 |
September | 0.08 | 3.30 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.17 | 0.00 |
Annual Sum or Average | 1.20 | 1.57 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.53 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.04 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.38 | 0.92 |
August | 0.00 | 0.00 |
September | 0.08 | 1.65 |
October | 0.06 | 0.00 |
November | 0.00 | 0.00 |
December | 0.17 | 0.00 |
Annual Sum or Average | 0.73 | 0.66 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.38 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.04 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.38 | 0.92 |
August | 0.00 | 0.00 |
September | 0.08 | 1.65 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.21 | 0.00 |
Annual Sum or Average | 0.71 | 0.67 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.38 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.14 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.38 | 0.92 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.27 | 0.00 |
Annual Sum or Average | 0.78 | 0.44 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.38 | 0.92 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.47 | 0.00 |
February | 0.72 | 0.00 |
March | 0.17 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.38 | 0.92 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.22 | 0.00 |
December | 1.63 | 0.00 |
Annual Sum or Average | 3.59 | 0.10 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.63 | 0.92 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.372351E+10 | 0.126217E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.336844E+10 | 0.104447E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.373029E+10 | 0.846938E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.374441E+10 | 0.105558E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.379755E+10 | 0.556158E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.414278E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.459595E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.448418E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.410115E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.372299E+10 | 0.962273E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.359754E+10 | 0.674093E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.373861E+10 | 0.142570E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.467474E+11 | 0.551078E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.336844E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.459595E+10 | 0.142570E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.161810E+10 | 0.380426E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.146226E+10 | 0.278111E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.164844E+10 | 0.210612E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.179498E+10 | 99870558.18 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.189359E+10 | 13930449.24 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.232678E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.258471E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.258023E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.232423E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.175163E+10 | 74552951.16 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.158073E+10 | 0.171144E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.160656E+10 | 0.438553E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.231722E+11 | 0.149768E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.146226E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.258471E+10 | 0.438553E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.172249E+10 | 0.518108E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.155967E+10 | 0.403331E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.175677E+10 | 0.319678E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.171254E+10 | 0.299579E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.177397E+10 | 60733431.42 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.193219E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.206589E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.212191E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.189745E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.172277E+10 | 0.312542E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.167107E+10 | 0.270618E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.171392E+10 | 0.581375E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.216506E+11 | 0.216040E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.155967E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.212191E+10 | 0.581375E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.172793E+10 | 0.557781E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.156459E+10 | 0.436990E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.176232E+10 | 0.354188E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.171581E+10 | 0.418893E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.177518E+10 | 0.117301E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.193170E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.206326E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.211653E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.189464E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.172805E+10 | 0.455987E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.167635E+10 | 0.306123E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.171933E+10 | 0.618678E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.216757E+11 | 0.237298E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.156459E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.211653E+10 | 0.618678E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.171307E+10 | 0.609212E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.155114E+10 | 0.482859E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.174716E+10 | 0.402047E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.169785E+10 | 0.589809E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.175451E+10 | 0.244048E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.190378E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.202787E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.207472E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.186345E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.171311E+10 | 0.663076E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.166193E+10 | 0.350782E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.170455E+10 | 0.671197E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.214131E+11 | 0.266579E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.155114E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.207472E+10 | 0.671197E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.265833E+10 | 0.133992E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.240755E+10 | 0.108533E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.271566E+10 | 0.965262E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.263463E+10 | 0.200132E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.271848E+10 | 0.124976E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.299492E+10 | 10901864.80 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.318466E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.324399E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.290311E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.265834E+10 | 0.245015E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.257952E+10 | 0.863446E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.264400E+10 | 0.144770E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.333432E+11 | 0.627286E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.240755E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.324399E+10 | 0.144770E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.143842E+10 | 0.777219E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.130272E+10 | 0.634854E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.146944E+10 | 0.572912E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.145691E+10 | 0.151209E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.151046E+10 | 0.104057E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.171200E+10 | 35051060.65 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.205646E+10 | 1405703.08 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.225655E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.177468E+10 | 294138.10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.144220E+10 | 0.175708E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.139577E+10 | 0.514247E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.143067E+10 | 0.834071E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.192463E+11 | 0.376795E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.130272E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.225655E+10 | 0.834071E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.142676E+10 | 0.791748E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.129216E+10 | 0.648356E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.145752E+10 | 0.587878E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.144028E+10 | 0.163013E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.149226E+10 | 0.116430E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.167730E+10 | 55580795.47 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.200853E+10 | 3683056.54 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.220498E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.173416E+10 | 3960705.92 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.142968E+10 | 0.188449E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.138446E+10 | 0.527821E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.141907E+10 | 0.847416E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.189672E+11 | 0.387743E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.129216E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.220498E+10 | 0.847416E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.140496E+10 | 0.841125E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.127241E+10 | 0.695679E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.143525E+10 | 0.638737E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.141029E+10 | 0.195391E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.145939E+10 | 0.149700E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.161842E+10 | 0.111091E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.191514E+10 | 16087299.05 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.209602E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.166502E+10 | 24354951.99 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.140677E+10 | 0.220844E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.136330E+10 | 0.570051E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.139738E+10 | 0.895485E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.184444E+11 | 0.422216E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.127241E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.209602E+10 | 0.895485E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.137529E+10 | 0.101810E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.124554E+10 | 0.863467E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.140494E+10 | 0.815909E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.136966E+10 | 0.295057E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.141618E+10 | 0.259612E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.154131E+10 | 0.374065E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.175636E+10 | 76832807.21 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.189454E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.156713E+10 | 0.151231E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.137588E+10 | 0.321134E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.133451E+10 | 0.709253E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.136787E+10 | 0.107911E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.176492E+11 | 0.542186E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.124554E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.189454E+10 | 0.107911E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.372351E+10 | 0.00 | 0.100974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.336844E+10 | 0.00 | 0.835579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.373029E+10 | 0.00 | 0.677550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.361202E+10 | 0.461656E+09 | 0.844467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.372282E+10 | 0.255980E+09 | 0.444927E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.361202E+10 | 0.187834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.373020E+10 | 0.300006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.372282E+10 | 0.264089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.361940E+10 | 0.168605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.372282E+10 | 558849.92 | 0.769819E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.359754E+10 | 0.00 | 0.539274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.373861E+10 | 0.00 | 0.114056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.439005E+11 | 0.992354E+10 | 0.440862E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.336844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.373861E+10 | 0.300006E+10 | 0.114056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.161809E+10 | 24639.19 | 0.304341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.146226E+10 | 12027.57 | 0.222489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.164836E+10 | 293054.70 | 0.168489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.171312E+10 | 0.325813E+09 | 79896446.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.183662E+10 | 0.224710E+09 | 11144359.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.203575E+10 | 0.116714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.210343E+10 | 0.191468E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.212456E+10 | 0.179920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.204778E+10 | 0.109527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174763E+10 | 14965321.12 | 59642360.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.158052E+10 | 711362.14 | 0.136915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.160655E+10 | 23541.82 | 0.350842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.215247E+11 | 0.654285E+10 | 0.119815E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.146226E+10 | 12027.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.212456E+10 | 0.191468E+10 | 0.350842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.172249E+10 | 0.00 | 0.414486E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155967E+10 | 0.00 | 0.322665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.175677E+10 | 0.00 | 0.255743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167107E+10 | 0.160576E+09 | 0.239663E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173963E+10 | 0.131484E+09 | 48586745.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.169678E+10 | 0.926944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.171392E+10 | 0.136231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.175677E+10 | 0.141450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167107E+10 | 0.883796E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.172249E+10 | 1029368.85 | 0.250033E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.167107E+10 | 0.00 | 0.216494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171392E+10 | 0.00 | 0.465100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203957E+11 | 0.488063E+10 | 0.172832E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.155967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.175677E+10 | 0.141450E+10 | 0.465100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.172793E+10 | 0.00 | 0.446224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.156459E+10 | 0.00 | 0.349592E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.176232E+10 | 0.00 | 0.283351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167635E+10 | 0.152638E+09 | 0.335115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.174512E+10 | 0.114725E+09 | 93840500.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.170214E+10 | 0.902480E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.171933E+10 | 0.132996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.176232E+10 | 0.137078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167635E+10 | 0.851024E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.172793E+10 | 453300.48 | 0.364790E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.167635E+10 | 0.00 | 0.244898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171933E+10 | 0.00 | 0.494942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.204601E+11 | 0.472207E+10 | 0.189838E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.156459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.176232E+10 | 0.137078E+10 | 0.494942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.171307E+10 | 0.00 | 0.487370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155114E+10 | 0.00 | 0.386287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.174716E+10 | 0.00 | 0.321637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.166193E+10 | 0.138570E+09 | 0.471847E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173011E+10 | 92831955.98 | 0.195239E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.168750E+10 | 0.848267E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.170455E+10 | 0.124771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.174716E+10 | 0.126578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.166193E+10 | 0.783993E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.171307E+10 | 166954.86 | 0.530461E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.166193E+10 | 0.00 | 0.280625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.170455E+10 | 0.00 | 0.536958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.202841E+11 | 0.437732E+10 | 0.213263E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.155114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.174716E+10 | 0.126578E+10 | 0.536958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.265833E+10 | 0.00 | 0.107193E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.240755E+10 | 0.00 | 0.868263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.271566E+10 | 0.00 | 0.772210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.257952E+10 | 0.189388E+09 | 0.160106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.268700E+10 | 0.106768E+09 | 0.999804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.262251E+10 | 0.129839E+10 | 8721491.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.264400E+10 | 0.185911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.271566E+10 | 0.182073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.257952E+10 | 0.112063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.265833E+10 | 11819.80 | 0.196012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.257952E+10 | 0.00 | 0.690757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.264400E+10 | 0.00 | 0.115816E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.314916E+11 | 0.639504E+10 | 0.501829E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.240755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.271566E+10 | 0.185911E+10 | 0.115816E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.143842E+10 | 0.00 | 0.621775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.130272E+10 | 0.00 | 0.507883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.146944E+10 | 0.00 | 0.458330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.139577E+10 | 0.234445E+09 | 0.120967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.145393E+10 | 0.214090E+09 | 0.832452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.141904E+10 | 0.113675E+10 | 28040848.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.143067E+10 | 0.241665E+10 | 1124562.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.146944E+10 | 0.304975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.139577E+10 | 0.147103E+10 | 235310.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143842E+10 | 14168050.13 | 0.140566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.139577E+10 | 0.00 | 0.411397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.143067E+10 | 0.00 | 0.667257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.170401E+11 | 0.853687E+10 | 0.301436E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.130272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.146944E+10 | 0.304975E+10 | 0.667257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.142676E+10 | 0.00 | 0.633398E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.129216E+10 | 0.00 | 0.518685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.145752E+10 | 0.00 | 0.470302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.138446E+10 | 0.213769E+09 | 0.130411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.144214E+10 | 0.189464E+09 | 0.931439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.140753E+10 | 0.104564E+10 | 44464636.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.141907E+10 | 0.227355E+10 | 2946445.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.145752E+10 | 0.289211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.138446E+10 | 0.135636E+10 | 3168564.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142676E+10 | 10931650.79 | 0.150759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.138446E+10 | 0.00 | 0.422256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.141907E+10 | 0.00 | 0.677933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.169019E+11 | 0.798183E+10 | 0.310195E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.129216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.145752E+10 | 0.289211E+10 | 0.677933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.140496E+10 | 0.00 | 0.672900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127241E+10 | 0.00 | 0.556543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143525E+10 | 0.00 | 0.510990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.136330E+10 | 0.179487E+09 | 0.156313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.142010E+10 | 0.148001E+09 | 0.119760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.138602E+10 | 0.898561E+09 | 88872440.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.139738E+10 | 0.199178E+10 | 12869839.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.143525E+10 | 0.254901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.136330E+10 | 0.116788E+10 | 19483961.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.140496E+10 | 6750578.09 | 0.176675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.136330E+10 | 0.00 | 0.456041E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.139738E+10 | 0.00 | 0.716388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.166436E+11 | 0.694146E+10 | 0.337773E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.127241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.143525E+10 | 0.254901E+10 | 0.716388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.137529E+10 | 0.00 | 0.814477E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124554E+10 | 0.00 | 0.690774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.140494E+10 | 0.00 | 0.652727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.133451E+10 | 0.133653E+09 | 0.236045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.139011E+10 | 97573146.50 | 0.207689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.135675E+10 | 0.710206E+09 | 0.299252E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.136787E+10 | 0.148820E+10 | 61466245.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.140494E+10 | 0.187743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.133451E+10 | 0.896611E+09 | 0.120985E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.137529E+10 | 2205036.39 | 0.256907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.133451E+10 | 0.00 | 0.567403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136787E+10 | 0.00 | 0.863291E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162921E+11 | 0.520588E+10 | 0.433748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.124554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.140494E+10 | 0.187743E+10 | 0.863291E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.372351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126217E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.336844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.373029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.846938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.361202E+10 | 0.00 | 0.00 | 0.00 | 0.132395E+09 | 0.00 | 0.105558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.372282E+10 | 0.00 | 0.00 | 0.00 | 74729525.75 | 0.00 | 0.556158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.361202E+10 | 0.00 | 0.00 | 0.00 | 0.530765E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.373020E+10 | 0.00 | 0.00 | 0.00 | 0.865748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.372282E+10 | 0.00 | 0.00 | 0.00 | 0.761362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.361940E+10 | 0.00 | 0.00 | 0.00 | 0.481747E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.372282E+10 | 0.00 | 0.00 | 0.00 | 170357.12 | 0.00 | 0.962273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.359754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.674093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.373861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142570E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.439005E+11 | 0.00 | 0.00 | 0.00 | 0.284692E+10 | 0.00 | 0.551078E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.336844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.373861E+10 | 0.00 | 0.00 | 0.00 | 0.865748E+09 | 0.00 | 0.142570E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.161809E+10 | 0.00 | 0.00 | 0.00 | 7301.09 | 0.00 | 0.380426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.146226E+10 | 0.00 | 0.00 | 0.00 | 3552.48 | 0.00 | 0.278111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.164836E+10 | 0.00 | 0.00 | 0.00 | 86742.66 | 0.00 | 0.210612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.171312E+10 | 0.00 | 0.00 | 0.00 | 81861792.03 | 0.00 | 99870558.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.183662E+10 | 0.00 | 0.00 | 0.00 | 56967490.89 | 0.00 | 13930449.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.203575E+10 | 0.00 | 0.00 | 0.00 | 0.291031E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.210343E+10 | 0.00 | 0.00 | 0.00 | 0.481280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.212456E+10 | 0.00 | 0.00 | 0.00 | 0.455667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.204778E+10 | 0.00 | 0.00 | 0.00 | 0.276447E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174763E+10 | 0.00 | 0.00 | 0.00 | 3995027.34 | 0.00 | 74552951.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.158052E+10 | 0.00 | 0.00 | 0.00 | 210299.19 | 0.00 | 0.171144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.160655E+10 | 0.00 | 0.00 | 0.00 | 6979.10 | 0.00 | 0.438553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.215247E+11 | 0.00 | 0.00 | 0.00 | 0.164756E+10 | 0.00 | 0.149768E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.146226E+10 | 0.00 | 0.00 | 0.00 | 3552.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.212456E+10 | 0.00 | 0.00 | 0.00 | 0.481280E+09 | 0.00 | 0.438553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.172249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.175677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167107E+10 | 0.00 | 0.00 | 0.00 | 41462545.05 | 0.00 | 0.299579E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173963E+10 | 0.00 | 0.00 | 0.00 | 34344252.60 | 0.00 | 60733431.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.169678E+10 | 0.00 | 0.00 | 0.00 | 0.235411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.171392E+10 | 0.00 | 0.00 | 0.00 | 0.351971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.175677E+10 | 0.00 | 0.00 | 0.00 | 0.365145E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167107E+10 | 0.00 | 0.00 | 0.00 | 0.226375E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.172249E+10 | 0.00 | 0.00 | 0.00 | 280325.41 | 0.00 | 0.312542E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.167107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270618E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.581375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203957E+11 | 0.00 | 0.00 | 0.00 | 0.125499E+10 | 0.00 | 0.216040E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.155967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.175677E+10 | 0.00 | 0.00 | 0.00 | 0.365145E+09 | 0.00 | 0.581375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.172793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.156459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.176232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167635E+10 | 0.00 | 0.00 | 0.00 | 39465283.50 | 0.00 | 0.418893E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.174512E+10 | 0.00 | 0.00 | 0.00 | 30057582.67 | 0.00 | 0.117301E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.170214E+10 | 0.00 | 0.00 | 0.00 | 0.229560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.171933E+10 | 0.00 | 0.00 | 0.00 | 0.343925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.176232E+10 | 0.00 | 0.00 | 0.00 | 0.354215E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167635E+10 | 0.00 | 0.00 | 0.00 | 0.218295E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.172793E+10 | 0.00 | 0.00 | 0.00 | 123487.54 | 0.00 | 0.455987E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.167635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.618678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.204601E+11 | 0.00 | 0.00 | 0.00 | 0.121564E+10 | 0.00 | 0.237298E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.156459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.176232E+10 | 0.00 | 0.00 | 0.00 | 0.354215E+09 | 0.00 | 0.618678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.171307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482859E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.174716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.166193E+10 | 0.00 | 0.00 | 0.00 | 35912332.78 | 0.00 | 0.589809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173011E+10 | 0.00 | 0.00 | 0.00 | 24398196.27 | 0.00 | 0.244048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.168750E+10 | 0.00 | 0.00 | 0.00 | 0.216279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.170455E+10 | 0.00 | 0.00 | 0.00 | 0.323327E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.174716E+10 | 0.00 | 0.00 | 0.00 | 0.327562E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.166193E+10 | 0.00 | 0.00 | 0.00 | 0.201522E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.171307E+10 | 0.00 | 0.00 | 0.00 | 45730.53 | 0.00 | 0.663076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.166193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.170455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.202841E+11 | 0.00 | 0.00 | 0.00 | 0.112905E+10 | 0.00 | 0.266579E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.155114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.174716E+10 | 0.00 | 0.00 | 0.00 | 0.327562E+09 | 0.00 | 0.671197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.265833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133992E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.240755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108533E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.271566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.965262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.257952E+10 | 0.00 | 0.00 | 0.00 | 55113244.12 | 0.00 | 0.200132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.268700E+10 | 0.00 | 0.00 | 0.00 | 31487398.51 | 0.00 | 0.124976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.262251E+10 | 0.00 | 0.00 | 0.00 | 0.372414E+09 | 0.00 | 10901864.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.264400E+10 | 0.00 | 0.00 | 0.00 | 0.540656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.271566E+10 | 0.00 | 0.00 | 0.00 | 0.528337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.257952E+10 | 0.00 | 0.00 | 0.00 | 0.323592E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.265833E+10 | 0.00 | 0.00 | 0.00 | 3623.82 | 0.00 | 0.245015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.257952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.264400E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144770E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.314916E+11 | 0.00 | 0.00 | 0.00 | 0.185160E+10 | 0.00 | 0.627286E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.240755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.271566E+10 | 0.00 | 0.00 | 0.00 | 0.540656E+09 | 0.00 | 0.144770E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.143842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.777219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.130272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.634854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.146944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.572912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.139577E+10 | 0.00 | 0.00 | 0.00 | 61137982.87 | 0.00 | 0.151209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.145393E+10 | 0.00 | 0.00 | 0.00 | 56523992.90 | 0.00 | 0.104057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.141904E+10 | 0.00 | 0.00 | 0.00 | 0.292964E+09 | 0.00 | 35051060.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.143067E+10 | 0.00 | 0.00 | 0.00 | 0.625788E+09 | 0.00 | 1405703.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.146944E+10 | 0.00 | 0.00 | 0.00 | 0.787109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.139577E+10 | 0.00 | 0.00 | 0.00 | 0.378907E+09 | 0.00 | 294138.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143842E+10 | 0.00 | 0.00 | 0.00 | 3775696.92 | 0.00 | 0.175708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.139577E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.143067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.834071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.170401E+11 | 0.00 | 0.00 | 0.00 | 0.220621E+10 | 0.00 | 0.376795E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.130272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.146944E+10 | 0.00 | 0.00 | 0.00 | 0.787109E+09 | 0.00 | 0.834071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.142676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.791748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.129216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.648356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.145752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.587878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.138446E+10 | 0.00 | 0.00 | 0.00 | 55824353.46 | 0.00 | 0.163013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.144214E+10 | 0.00 | 0.00 | 0.00 | 50115021.81 | 0.00 | 0.116430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.140753E+10 | 0.00 | 0.00 | 0.00 | 0.269766E+09 | 0.00 | 55580795.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.141907E+10 | 0.00 | 0.00 | 0.00 | 0.589465E+09 | 0.00 | 3683056.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.145752E+10 | 0.00 | 0.00 | 0.00 | 0.747459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.138446E+10 | 0.00 | 0.00 | 0.00 | 0.349707E+09 | 0.00 | 3960705.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142676E+10 | 0.00 | 0.00 | 0.00 | 2921205.82 | 0.00 | 0.188449E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.138446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.527821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.141907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.847416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.169019E+11 | 0.00 | 0.00 | 0.00 | 0.206526E+10 | 0.00 | 0.387743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.129216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.145752E+10 | 0.00 | 0.00 | 0.00 | 0.747459E+09 | 0.00 | 0.847416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.140496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.841125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.695679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.638737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.136330E+10 | 0.00 | 0.00 | 0.00 | 46994474.55 | 0.00 | 0.195391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.142010E+10 | 0.00 | 0.00 | 0.00 | 39283863.16 | 0.00 | 0.149700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.138602E+10 | 0.00 | 0.00 | 0.00 | 0.232401E+09 | 0.00 | 0.111091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.139738E+10 | 0.00 | 0.00 | 0.00 | 0.517760E+09 | 0.00 | 16087299.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.143525E+10 | 0.00 | 0.00 | 0.00 | 0.660769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.136330E+10 | 0.00 | 0.00 | 0.00 | 0.301724E+09 | 0.00 | 24354951.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.140496E+10 | 0.00 | 0.00 | 0.00 | 1811322.36 | 0.00 | 0.220844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.136330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.570051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.139738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.895485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.166436E+11 | 0.00 | 0.00 | 0.00 | 0.180074E+10 | 0.00 | 0.422216E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.127241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.143525E+10 | 0.00 | 0.00 | 0.00 | 0.660769E+09 | 0.00 | 0.895485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.137529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.140494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.815909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.133451E+10 | 0.00 | 0.00 | 0.00 | 35151736.07 | 0.00 | 0.295057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.139011E+10 | 0.00 | 0.00 | 0.00 | 26068467.19 | 0.00 | 0.259612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.135675E+10 | 0.00 | 0.00 | 0.00 | 0.184554E+09 | 0.00 | 0.374065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.136787E+10 | 0.00 | 0.00 | 0.00 | 0.388490E+09 | 0.00 | 76832807.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.140494E+10 | 0.00 | 0.00 | 0.00 | 0.489597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.133451E+10 | 0.00 | 0.00 | 0.00 | 0.232621E+09 | 0.00 | 0.151231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.137529E+10 | 0.00 | 0.00 | 0.00 | 597539.01 | 0.00 | 0.321134E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.133451E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.709253E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107911E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162921E+11 | 0.00 | 0.00 | 0.00 | 0.135708E+10 | 0.00 | 0.542186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.124554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.140494E+10 | 0.00 | 0.00 | 0.00 | 0.489597E+09 | 0.00 | 0.107911E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.846027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.575850E+10 | 0.00 | 0.00 | 0.52 |
February | 0.760697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.497840E+10 | 0.00 | 0.00 | 0.53 |
March | 0.803424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442803E+10 | 0.00 | 0.00 | 0.53 |
April | 0.814067E+10 | 0.00 | 0.00 | 3951227.40 | 847242.20 | 0.271669E+09 | 0.227855E+10 | 0.00 | 0.62 |
May | 0.780343E+10 | 404732.03 | 0.00 | 4063280.83 | 0.00 | 42146722.31 | 0.297512E+10 | 0.00 | 0.63 |
June | 0.229053E+10 | 83565613.58 | 0.00 | 12165121.03 | 47339.40 | 0.00 | 0.840138E+10 | 0.00 | 0.83 |
July | 0.729377E+09 | 0.120842E+09 | 0.00 | 20051682.62 | 678365.72 | 0.00 | 0.113779E+11 | 0.00 | 1.10 |
August | 0.184983E+09 | 2911735.85 | 0.00 | 21885796.95 | 0.00 | 0.00 | 0.126461E+11 | 0.00 | 1.29 |
September | 0.896108E+09 | 0.00 | 0.00 | 16905217.67 | 0.00 | 0.00 | 0.107366E+11 | 0.00 | 0.97 |
October | 0.800546E+10 | 0.00 | 0.00 | 1919633.24 | 0.00 | 0.185145E+09 | 0.244419E+10 | 0.00 | 0.55 |
November | 0.823202E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346599E+10 | 0.00 | 0.00 | 0.52 |
December | 0.780580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.652127E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.681899E+11 | 0.207725E+09 | 0.00 | 80941959.73 | 1572947.32 | 0.256511E+11 | 0.508598E+11 | 0.00 | 0.72 |
Minimum of Months | 0.184983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
Maximum of Months | 0.846027E+10 | 0.120842E+09 | 0.00 | 21885796.95 | 847242.20 | 0.652127E+10 | 0.126461E+11 | 0.00 | 1.29 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.302042E+10 | 0.00 | 0.00 | 52174.82 | 0.00 | 0.208968E+10 | 40580789.90 | 0.00 | 0.39 |
February | 0.275792E+10 | 0.00 | 0.00 | 24986.22 | 0.00 | 0.167236E+10 | 19025703.17 | 0.00 | 0.39 |
March | 0.329565E+10 | 0.00 | 0.00 | 115726.26 | 0.00 | 0.122709E+10 | 91319090.45 | 0.00 | 0.40 |
April | 0.258851E+10 | 151792.08 | 0.00 | 3509117.78 | 340819.01 | 48699788.97 | 0.228405E+10 | 0.00 | 0.58 |
May | 0.255841E+10 | 313723.76 | 0.00 | 3712235.97 | 0.00 | 0.00 | 0.275816E+10 | 0.00 | 0.62 |
June | 0.443034E+09 | 44941486.06 | 0.00 | 8715006.15 | 0.00 | 0.00 | 0.591760E+10 | 0.00 | 0.98 |
July | 0.101162E+09 | 57289169.67 | 0.00 | 11630195.24 | 0.00 | 0.00 | 0.694816E+10 | 0.00 | 1.26 |
August | 9499279.08 | 1870359.88 | 0.00 | 12785984.04 | 0.00 | 0.00 | 0.745111E+10 | 0.00 | 1.49 |
September | 0.194410E+09 | 0.00 | 0.00 | 10787079.05 | 0.00 | 0.00 | 0.670438E+10 | 0.00 | 1.15 |
October | 0.259321E+10 | 0.00 | 0.00 | 2771911.56 | 0.00 | 0.00 | 0.230544E+10 | 0.00 | 0.51 |
November | 0.338144E+10 | 0.00 | 0.00 | 176213.26 | 0.00 | 0.846492E+09 | 0.131458E+09 | 0.00 | 0.39 |
December | 0.227649E+10 | 0.00 | 0.00 | 4708.24 | 0.00 | 0.276421E+10 | 3635583.07 | 0.00 | 0.38 |
Annual Sum or Average | 0.232202E+11 | 0.104567E+09 | 0.00 | 54285338.57 | 340819.01 | 0.864853E+10 | 0.346549E+11 | 0.00 | 0.71 |
Minimum of Months | 9499279.08 | 0.00 | 0.00 | 4708.24 | 0.00 | 0.00 | 3635583.07 | 0.00 | 0.38 |
Maximum of Months | 0.338144E+10 | 57289169.67 | 0.00 | 12785984.04 | 340819.01 | 0.276421E+10 | 0.745111E+10 | 0.00 | 1.49 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.260655E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278817E+10 | 0.00 | 0.00 | 0.41 |
February | 0.222835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.246632E+10 | 0.00 | 0.00 | 0.41 |
March | 0.275458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203302E+10 | 0.00 | 0.00 | 0.42 |
April | 0.302251E+10 | 0.00 | 0.00 | 1208716.45 | 447991.77 | 0.113770E+09 | 0.952697E+09 | 0.00 | 0.51 |
May | 0.301536E+10 | 298817.83 | 0.00 | 1331818.02 | 0.00 | 1624428.11 | 0.120125E+10 | 0.00 | 0.53 |
June | 0.943980E+09 | 26354422.94 | 0.00 | 4264233.15 | 59104.81 | 0.00 | 0.333862E+10 | 0.00 | 0.74 |
July | 0.499791E+09 | 45793704.53 | 0.00 | 6135376.63 | 1904985.06 | 0.00 | 0.428054E+10 | 0.00 | 0.96 |
August | 0.307084E+09 | 1880329.57 | 0.00 | 7654869.66 | 0.00 | 0.00 | 0.488638E+10 | 0.00 | 1.18 |
September | 0.714343E+09 | 0.00 | 0.00 | 5647379.46 | 0.00 | 0.00 | 0.388119E+10 | 0.00 | 0.88 |
October | 0.307429E+10 | 0.00 | 0.00 | 893369.69 | 0.00 | 32555790.89 | 0.949422E+09 | 0.00 | 0.45 |
November | 0.284375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159816E+10 | 0.00 | 0.00 | 0.41 |
December | 0.209506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325721E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.241057E+11 | 74327274.86 | 0.00 | 27135763.07 | 2412081.64 | 0.122908E+11 | 0.194901E+11 | 0.00 | 0.61 |
Minimum of Months | 0.307084E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.307429E+10 | 45793704.53 | 0.00 | 7654869.66 | 1904985.06 | 0.325721E+10 | 0.488638E+10 | 0.00 | 1.18 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.238986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300312E+10 | 0.00 | 0.00 | 0.41 |
February | 0.212760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256699E+10 | 0.00 | 0.00 | 0.41 |
March | 0.260169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.218145E+10 | 0.00 | 0.00 | 0.42 |
April | 0.301069E+10 | 0.00 | 0.00 | 1066689.04 | 492762.27 | 0.157274E+09 | 0.841343E+09 | 0.00 | 0.51 |
May | 0.306066E+10 | 240776.25 | 0.00 | 1196518.12 | 0.00 | 4747077.10 | 0.106794E+10 | 0.00 | 0.52 |
June | 0.102965E+10 | 26029963.54 | 0.00 | 3975193.83 | 57793.45 | 0.00 | 0.315739E+10 | 0.00 | 0.73 |
July | 0.549429E+09 | 45670744.71 | 0.00 | 5936988.42 | 1903236.28 | 0.00 | 0.417089E+10 | 0.00 | 0.95 |
August | 0.319199E+09 | 1822900.06 | 0.00 | 7474915.86 | 0.00 | 0.00 | 0.484402E+10 | 0.00 | 1.17 |
September | 0.745124E+09 | 0.00 | 0.00 | 5427207.85 | 0.00 | 0.00 | 0.377216E+10 | 0.00 | 0.87 |
October | 0.301316E+10 | 0.00 | 0.00 | 735495.25 | 0.00 | 0.133126E+09 | 0.823609E+09 | 0.00 | 0.44 |
November | 0.261330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181876E+10 | 0.00 | 0.00 | 0.41 |
December | 0.199271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336024E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.234531E+11 | 73764384.57 | 0.00 | 25813008.38 | 2453792.00 | 0.132257E+11 | 0.186774E+11 | 0.00 | 0.61 |
Minimum of Months | 0.319199E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.306066E+10 | 45670744.71 | 0.00 | 7474915.86 | 1903236.28 | 0.336024E+10 | 0.484402E+10 | 0.00 | 1.17 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.211960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327073E+10 | 0.00 | 0.00 | 0.41 |
February | 0.194905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274417E+10 | 0.00 | 0.00 | 0.41 |
March | 0.233774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243921E+10 | 0.00 | 0.00 | 0.42 |
April | 0.301423E+10 | 0.00 | 0.00 | 858504.35 | 591398.28 | 0.224110E+09 | 0.646049E+09 | 0.00 | 0.50 |
May | 0.307736E+10 | 189153.38 | 0.00 | 994099.07 | 0.00 | 23776575.78 | 0.893817E+09 | 0.00 | 0.51 |
June | 0.129463E+10 | 25132429.05 | 0.00 | 3323713.81 | 51992.41 | 0.00 | 0.264895E+10 | 0.00 | 0.69 |
July | 0.606322E+09 | 45215271.94 | 0.00 | 5396660.13 | 1952214.40 | 0.00 | 0.391012E+10 | 0.00 | 0.92 |
August | 0.360757E+09 | 1704024.49 | 0.00 | 6935940.18 | 0.00 | 0.00 | 0.463028E+10 | 0.00 | 1.14 |
September | 0.817982E+09 | 0.00 | 0.00 | 4885523.34 | 0.00 | 0.00 | 0.348092E+10 | 0.00 | 0.83 |
October | 0.283362E+10 | 0.00 | 0.00 | 466677.20 | 0.00 | 0.422050E+09 | 0.587455E+09 | 0.00 | 0.43 |
November | 0.232415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209836E+10 | 0.00 | 0.00 | 0.41 |
December | 0.183217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351972E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.225676E+11 | 72240878.85 | 0.00 | 22861118.07 | 2595605.09 | 0.147421E+11 | 0.167976E+11 | 0.00 | 0.59 |
Minimum of Months | 0.360757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.307736E+10 | 45215271.94 | 0.00 | 6935940.18 | 1952214.40 | 0.351972E+10 | 0.463028E+10 | 0.00 | 1.14 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.229732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.762411E+10 | 0.00 | 0.00 | 0.38 |
February | 0.284497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.579456E+10 | 0.00 | 0.00 | 0.38 |
March | 0.333694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.546159E+10 | 0.00 | 0.00 | 0.39 |
April | 0.502959E+10 | 0.00 | 0.00 | 1010365.05 | 1113308.93 | 0.853558E+09 | 0.797124E+09 | 0.00 | 0.43 |
May | 0.517376E+10 | 0.00 | 0.00 | 1118011.12 | 0.00 | 0.446196E+09 | 0.119068E+10 | 0.00 | 0.43 |
June | 0.313044E+10 | 36831691.04 | 0.00 | 3875142.29 | 0.00 | 1734901.81 | 0.304256E+10 | 0.00 | 0.55 |
July | 0.116125E+10 | 74900073.04 | 0.00 | 7731639.75 | 3894117.75 | 0.00 | 0.591482E+10 | 0.00 | 0.72 |
August | 0.329612E+09 | 791677.96 | 0.00 | 10682229.14 | 0.00 | 0.00 | 0.755793E+10 | 0.00 | 0.90 |
September | 0.166418E+10 | 0.00 | 0.00 | 6407453.45 | 0.00 | 0.00 | 0.494186E+10 | 0.00 | 0.65 |
October | 0.502774E+10 | 0.00 | 0.00 | 155616.52 | 0.00 | 0.141735E+10 | 0.220439E+09 | 0.00 | 0.38 |
November | 0.332524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.479663E+10 | 0.00 | 0.00 | 0.38 |
December | 0.204705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.780264E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.353681E+11 | 0.112523E+09 | 0.00 | 30980457.33 | 5007426.68 | 0.341984E+11 | 0.236654E+11 | 0.00 | 0.50 |
Minimum of Months | 0.329612E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.517376E+10 | 74900073.04 | 0.00 | 10682229.14 | 3894117.75 | 0.780264E+10 | 0.755793E+10 | 0.00 | 0.90 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.102596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442162E+10 | 0.00 | 0.00 | 0.41 |
February | 0.132207E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342360E+10 | 0.00 | 0.00 | 0.41 |
March | 0.151948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331108E+10 | 0.00 | 0.00 | 0.42 |
April | 0.234114E+10 | 0.00 | 0.00 | 436837.31 | 1206091.97 | 0.937856E+09 | 0.196499E+09 | 0.00 | 0.41 |
May | 0.252699E+10 | 5102.92 | 0.00 | 436590.90 | 0.00 | 0.666105E+09 | 0.293580E+09 | 0.00 | 0.42 |
June | 0.191925E+10 | 19446702.16 | 0.00 | 1566324.99 | 0.00 | 12336231.34 | 0.761981E+09 | 0.00 | 0.42 |
July | 0.862288E+09 | 37506367.49 | 0.00 | 3484331.25 | 2314956.75 | 0.00 | 0.129989E+10 | 0.00 | 0.41 |
August | 0.393242E+09 | 641607.10 | 0.00 | 5012599.52 | 0.00 | 0.00 | 0.153303E+10 | 0.00 | 0.43 |
September | 0.124692E+10 | 0.00 | 0.00 | 2790607.17 | 0.00 | 0.00 | 0.124205E+10 | 0.00 | 0.42 |
October | 0.245608E+10 | 0.00 | 0.00 | 44527.89 | 0.00 | 0.112103E+10 | 56502965.75 | 0.00 | 0.41 |
November | 0.146240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300103E+10 | 0.00 | 0.00 | 0.41 |
December | 0.921880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.448603E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.179977E+11 | 57599779.66 | 0.00 | 13771819.03 | 3521048.72 | 0.213807E+11 | 0.538354E+10 | 0.00 | 0.42 |
Minimum of Months | 0.393242E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.252699E+10 | 37506367.49 | 0.00 | 5012599.52 | 2314956.75 | 0.448603E+10 | 0.153303E+10 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.988982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.445844E+10 | 0.00 | 0.00 | 0.41 |
February | 0.128349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346208E+10 | 0.00 | 0.00 | 0.41 |
March | 0.148593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.334440E+10 | 0.00 | 0.00 | 0.42 |
April | 0.228116E+10 | 0.00 | 0.00 | 395254.16 | 1288339.56 | 0.999412E+09 | 0.182882E+09 | 0.00 | 0.41 |
May | 0.244074E+10 | 1782.54 | 0.00 | 371575.29 | 0.00 | 0.773171E+09 | 0.255995E+09 | 0.00 | 0.42 |
June | 0.198036E+10 | 18860688.43 | 0.00 | 1362745.65 | 0.00 | 23348677.84 | 0.659345E+09 | 0.00 | 0.42 |
July | 0.899595E+09 | 37259526.72 | 0.00 | 3246118.64 | 2332958.60 | 1260147.49 | 0.125271E+10 | 0.00 | 0.41 |
August | 0.407651E+09 | 586049.56 | 0.00 | 4779310.97 | 0.00 | 0.00 | 0.152325E+10 | 0.00 | 0.43 |
September | 0.134233E+10 | 0.00 | 0.00 | 2516655.68 | 0.00 | 0.00 | 0.113003E+10 | 0.00 | 0.42 |
October | 0.237244E+10 | 0.00 | 0.00 | 30607.65 | 0.00 | 0.120881E+10 | 34410090.15 | 0.00 | 0.41 |
November | 0.139588E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306716E+10 | 0.00 | 0.00 | 0.41 |
December | 0.843729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456408E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.177223E+11 | 56708047.26 | 0.00 | 12702268.04 | 3621298.16 | 0.219022E+11 | 0.503862E+10 | 0.00 | 0.42 |
Minimum of Months | 0.407651E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.244074E+10 | 37259526.72 | 0.00 | 4779310.97 | 2332958.60 | 0.456408E+10 | 0.152325E+10 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.810464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.463602E+10 | 0.00 | 0.00 | 0.41 |
February | 0.102554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.371919E+10 | 0.00 | 0.00 | 0.41 |
March | 0.128478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354459E+10 | 0.00 | 0.00 | 0.42 |
April | 0.205105E+10 | 0.00 | 0.00 | 326817.81 | 1429536.33 | 0.123255E+10 | 0.158501E+09 | 0.00 | 0.41 |
May | 0.230151E+10 | 0.00 | 0.00 | 279803.80 | 0.00 | 0.951345E+09 | 0.188054E+09 | 0.00 | 0.42 |
June | 0.207110E+10 | 17791483.53 | 0.00 | 1054102.25 | 0.00 | 38943993.71 | 0.492458E+09 | 0.00 | 0.42 |
July | 0.992557E+09 | 36748217.53 | 0.00 | 2776168.47 | 2368002.11 | 10100895.70 | 0.113461E+10 | 0.00 | 0.41 |
August | 0.455838E+09 | 478445.58 | 0.00 | 4258006.92 | 0.00 | 0.00 | 0.148110E+10 | 0.00 | 0.43 |
September | 0.153658E+10 | 0.00 | 0.00 | 2071112.67 | 0.00 | 3566917.53 | 0.895555E+09 | 0.00 | 0.42 |
October | 0.213601E+10 | 0.00 | 0.00 | 18717.06 | 0.00 | 0.142833E+10 | 22711572.17 | 0.00 | 0.41 |
November | 0.119526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326672E+10 | 0.00 | 0.00 | 0.41 |
December | 0.556666E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.485042E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.164174E+11 | 55018146.63 | 0.00 | 10784728.99 | 3797538.43 | 0.236818E+11 | 0.437298E+10 | 0.00 | 0.42 |
Minimum of Months | 0.455838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.230151E+10 | 36748217.53 | 0.00 | 4258006.92 | 2368002.11 | 0.485042E+10 | 0.148110E+10 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.189040E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.524891E+10 | 0.00 | 0.00 | 0.41 |
February | 69505849.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.465969E+10 | 0.00 | 0.00 | 0.41 |
March | 0.364359E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.444974E+10 | 0.00 | 0.00 | 0.42 |
April | 0.153685E+10 | 0.00 | 1209798.82 | 228218.45 | 241637.64 | 0.174579E+10 | 0.108703E+09 | 961.20 | 0.41 |
May | 0.179890E+10 | 0.00 | 0.00 | 150951.97 | 0.00 | 0.147901E+10 | 93047321.49 | 0.00 | 0.42 |
June | 0.197793E+10 | 16135687.01 | 0.00 | 704893.99 | 921520.25 | 0.215296E+09 | 0.257515E+09 | 0.00 | 0.42 |
July | 0.112083E+10 | 36770852.56 | 0.00 | 1880528.26 | 2876275.94 | 44748807.79 | 0.907125E+09 | 0.00 | 0.41 |
August | 0.574707E+09 | 367107.32 | 0.00 | 3136118.89 | 0.00 | 0.00 | 0.133215E+10 | 0.00 | 0.43 |
September | 0.165736E+10 | 0.00 | 0.00 | 1461563.38 | 0.00 | 81952911.02 | 0.574578E+09 | 0.00 | 0.42 |
October | 0.166610E+10 | 0.00 | 0.00 | 6873.50 | 0.00 | 0.183964E+10 | 11738356.72 | 0.00 | 0.41 |
November | 0.589482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.385175E+10 | 0.00 | 0.00 | 0.41 |
December | 34766564.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.535143E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.115798E+11 | 53273646.88 | 1209798.82 | 7569148.43 | 4039433.83 | 0.289680E+11 | 0.328486E+10 | 961.20 | 0.42 |
Minimum of Months | 34766564.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.197793E+10 | 36770852.56 | 1209798.82 | 3136118.89 | 2876275.94 | 0.535143E+10 | 0.133215E+10 | 961.20 | 0.43 |