Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:18
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Simulation Timestamp: 2020-06-03 19:19:00
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2339.93 | 1119.41 | 1119.41 |
Net Site Energy | 2339.93 | 1119.41 | 1119.41 |
Total Source Energy | 5578.01 | 2668.50 | 2668.50 |
Net Source Energy | 5578.01 | 2668.50 | 2668.50 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 879.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 85.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 708.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 166.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 304.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 66.08 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1460.16 | 879.76 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 879.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 85.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 708.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 166.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 304.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 66.08 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 418.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 218.16 | 420.88 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 698.54 | 420.88 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 418.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 218.16 | 420.88 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 698.54 | 420.88 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1460.164 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1460.164 | 100.00 |
Total On-Site and Utility Electric Sources | 1460.164 | 100.00 |
Total Electricity End Uses | 1460.164 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 3.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2403.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2006
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:18 |
RunPeriod | RUNPERIOD 1 |
Weather File | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Latitude [deg] | 47.47 |
Longitude [deg] | -111.4 |
Elevation [m] | 1117.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 28.8173 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 28.8173 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 22.6280 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 22.6280 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 22.6280 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 18.3225 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0226 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0226 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 17-JUL-15:00 | 08-JAN-17:00 | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 438828.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 64387.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 43732.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 5445.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 139349.83 | 438828.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 438828.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 64387.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 43732.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 5445.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 953.67 | 0.00 | 0.00 | 0.00 |
Cooling | 270.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 2244.57 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 527.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 407.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 964.65 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 209.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4624.34 | 953.67 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 456.23 | 0.00 | 0.00 | 0.00 |
Cooling | 129.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1073.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 252.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 461.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 100.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2212.27 | 456.23 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 456.23 | 0.00 | 0.00 | 0.00 |
Cooling | 129.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1073.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 252.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 461.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 100.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2212.27 | 456.23 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 2.59 |
SMSTORE1 DIRECT AIR | 1.36 |
SMSTORE2 DIRECT AIR | 1.30 |
SMSTORE3 DIRECT AIR | 1.30 |
SMSTORE4 DIRECT AIR | 1.31 |
LGSTORE2 DIRECT AIR | 2.42 |
SMSTORE5 DIRECT AIR | 1.33 |
SMSTORE6 DIRECT AIR | 1.33 |
SMSTORE7 DIRECT AIR | 1.34 |
SMSTORE8 DIRECT AIR | 1.51 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 2.59 | 2.59 | 2.59 | 2.59 | 2.59 | 2.59 | 1.00 | 1.00 | 2.59 |
PSZ-AC_2:2 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.00 | 1.00 | 1.36 |
PSZ-AC_3:3 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.00 | 1.00 | 1.30 |
PSZ-AC_4:4 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.00 | 1.00 | 1.30 |
PSZ-AC_5:5 | 1.31 | 1.31 | 1.31 | 1.31 | 1.31 | 1.31 | 1.00 | 1.00 | 1.31 |
PSZ-AC_6:6 | 2.42 | 2.42 | 2.42 | 2.42 | 2.42 | 2.42 | 1.00 | 1.00 | 2.42 |
PSZ-AC_7:7 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.00 | 1.00 | 1.33 |
PSZ-AC_8:8 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.00 | 1.00 | 1.33 |
PSZ-AC_9:9 | 1.34 | 1.34 | 1.34 | 1.34 | 1.34 | 1.34 | 1.00 | 1.00 | 1.34 |
PSZ-AC_10:10 | 1.51 | 1.51 | 1.51 | 1.51 | 1.51 | 1.51 | 1.00 | 1.00 | 1.51 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 2.59 | 0.530908 |
PSZ-AC_2:2_OA_CONTROLLER | 1.36 | 0.265454 |
PSZ-AC_3:3_OA_CONTROLLER | 1.30 | 0.265454 |
PSZ-AC_4:4_OA_CONTROLLER | 1.30 | 0.265454 |
PSZ-AC_5:5_OA_CONTROLLER | 1.31 | 0.265454 |
PSZ-AC_6:6_OA_CONTROLLER | 2.42 | 0.530908 |
PSZ-AC_7:7_OA_CONTROLLER | 1.33 | 0.265454 |
PSZ-AC_8:8_OA_CONTROLLER | 1.33 | 0.265454 |
PSZ-AC_9:9_OA_CONTROLLER | 1.34 | 0.265454 |
PSZ-AC_10:10_OA_CONTROLLER | 1.51 | 0.265454 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 2.59 | 2.59 | 2.59 | 2.59 | 43301.64 | 79194.80 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.36 | 1.36 | 1.36 | 1.36 | 22648.30 | 40936.51 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.30 | 1.30 | 1.30 | 1.30 | 21668.70 | 39598.60 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.30 | 1.30 | 1.30 | 1.30 | 21730.74 | 39664.03 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.31 | 1.31 | 1.31 | 1.31 | 21874.03 | 39823.82 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 2.42 | 2.42 | 2.42 | 2.42 | 40978.42 | 75830.85 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 1.33 | 1.33 | 1.33 | 1.33 | 22332.29 | 40228.09 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 1.33 | 1.33 | 1.33 | 1.33 | 22330.57 | 40203.39 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 1.34 | 1.34 | 1.34 | 1.34 | 22562.62 | 40449.44 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 1.51 | 1.51 | 1.51 | 1.51 | 25394.14 | 43840.26 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 2.59 | 1.30 | 2.59 | 42904.82 | 43301.64 | 21650.82 | 43301.64 | 0.795286 | 0.795290 | 0.795290 | 0.795290 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 1.36 | 0.681435 | 1.36 | 22560.34 | 22648.30 | 11324.15 | 22648.30 | 0.797227 | 0.797230 | 0.797230 | 0.797230 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.30 | 0.647985 | 1.30 | 21452.91 | 21668.70 | 10834.35 | 21668.70 | 0.794994 | 0.794990 | 0.794990 | 0.794990 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 1.30 | 0.649620 | 1.30 | 21507.04 | 21730.74 | 10865.37 | 21730.74 | 0.794870 | 0.794870 | 0.794870 | 0.794870 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 1.31 | 0.653615 | 1.31 | 21639.30 | 21874.03 | 10937.01 | 21874.03 | 0.794710 | 0.794710 | 0.794710 | 0.794710 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 2.42 | 1.21 | 2.42 | 40120.51 | 40978.42 | 20489.21 | 40978.42 | 0.790958 | 0.790960 | 0.790960 | 0.790960 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 1.33 | 0.663725 | 1.33 | 21974.01 | 22332.29 | 11166.15 | 22332.29 | 0.792757 | 0.792760 | 0.792760 | 0.792760 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 1.33 | 0.663110 | 1.33 | 21953.65 | 22330.57 | 11165.28 | 22330.57 | 0.792450 | 0.792450 | 0.792450 | 0.792450 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 1.34 | 0.669260 | 1.34 | 22157.26 | 22562.62 | 11281.31 | 22562.62 | 0.792050 | 0.792050 | 0.792050 | 0.792050 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 1.51 | 0.754030 | 1.51 | 24963.75 | 25394.14 | 12697.07 | 25394.14 | 0.792424 | 0.792420 | 0.792420 | 0.792420 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.59 | 2836.83 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.36 | 1553.82 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.30 | 1477.55 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.30 | 1481.28 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.31 | 1490.39 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 2.42 | 2652.74 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 1.33 | 1513.44 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 1.33 | 1512.03 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 1.34 | 1526.06 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 1.51 | 1650.58 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 79194.80 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 40936.51 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 39598.60 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 39664.03 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 39823.82 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 75830.85 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 40228.09 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 40203.39 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 40449.44 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 43840.26 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 8.60 | 2.80 | -4.10 | -8.80 | -2.20 | 0.30 | 6.70 | 10.10 | 16.50 | 20.60 | 19.20 | 14.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 | 47.47 | -111.38 | -7.00 | 1117.00 | 88606 | 1.0531 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 7.03 | 29.40 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 28.817 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 33.117 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 28.817 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 33.117 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 22.628 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 26.928 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 22.628 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 26.928 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 22.628 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 26.928 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 3656.252 | 10.495 | 121.891 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3656.252 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1828.126 | 10.495 | 121.891 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1828.126 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 750.000 | 4.306 | 50.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 750.000 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 750.000 | 4.306 | 50.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 750.000 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 750.000 | 4.306 | 50.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 750.000 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.5136 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1995 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2888 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.713 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.937 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.386 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
19 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
20 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
21 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
22 | 7 | -0.33207909E-12 | 0.79542070E-15 | -0.11586622E-12 | 0.10783435E-15 |
23 | 6 | 0.31762832E-07 | 0.14865645E-09 | 0.72503568E-08 | -0.15188138E-12 |
24 | 5 | -0.20568023E-03 | 0.12486053E-05 | -0.10556626E-03 | 0.71569697E-08 |
25 | 4 | 0.31018727 | 0.59758545E-03 | 0.10618022 | -0.36135240E-04 |
26 | 3 | -7.6231853 | 0.18239075E-01 | -2.4448349 | 0.30759039E-01 |
27 | 2 | 42.047589 | 0.63983780E-01 | 15.698525 | -0.34644559 |
28 | 1 | -81.446794 | 0.28535822E-01 | -29.529986 | 1.0978209 |
29 | 0 | 46.824333 | 0.56745654E-03 | 16.282146 | |
30 | 7 | -0.21163652E-08 | -0.68723841E-15 | 0.43910983E-14 | -0.57684426E-16 |
31 | 6 | 0.56109385E-05 | 0.38186281E-08 | 0.31898696E-02 | -0.26759299E-04 |
32 | 5 | -0.40164657E-03 | 0.22608617E-05 | -0.22372456 | 0.19561502E-02 |
33 | 4 | 0.92272104E-02 | 0.10289840E-03 | 4.8295456 | -0.45264980E-01 |
34 | 3 | -0.80993241E-01 | 0.81813938E-03 | -38.021416 | 0.39865375 |
35 | 2 | 0.28754352 | 0.13608947E-02 | 116.48395 | -1.4179393 |
36 | 1 | -0.41499682 | 0.41453381E-03 | -143.90731 | 2.0490399 |
37 | 0 | 0.20232414 | 0.10048102E-04 | 60.838472 | |
38 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
39 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
40 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
41 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
42 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
43 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
44 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
45 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
46 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
47 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
48 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
49 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
50 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
51 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
52 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
53 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
54 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
55 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
56 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
57 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
58 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
59 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
60 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
61 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
62 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
63 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
64 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
65 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
66 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
67 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
68 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
69 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
70 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
71 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
72 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
73 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
74 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
75 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
76 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
77 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
78 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
79 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
80 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
81 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
82 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
83 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
84 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
85 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
86 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
87 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
88 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
89 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
90 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
91 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
92 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
93 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
94 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479936E-14 | -0.41635794E-16 |
95 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
96 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
97 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
98 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
99 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
100 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
101 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
102 | 7 | -0.14484255E-08 | -0.22640907E-15 | 0.11860658E-13 | -0.17473455E-15 |
103 | 6 | 0.80640390E-05 | 0.55493782E-08 | 0.31828288E-02 | -0.26700235E-04 |
104 | 5 | -0.58275339E-03 | 0.32892043E-05 | -0.22332434 | 0.19526176E-02 |
105 | 4 | 0.13421983E-01 | 0.14977251E-03 | 4.8228790 | -0.45200897E-01 |
106 | 3 | -0.11791368 | 0.11914425E-02 | -37.983753 | 0.39823745 |
107 | 2 | 0.41875064 | 0.19825898E-02 | 116.41064 | -1.4169588 |
108 | 1 | -0.60444169 | 0.60433957E-03 | -143.86415 | 2.0483306 |
109 | 0 | 0.29470347 | 0.14596444E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 29 | 1 | VerySmooth | 2.672 | 0.394 | 0.315 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.40629E-002 | 0.31435 | 0.46917 | 0.46917 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11822 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.286 | 8.224E-004 | 4.530E-004 | 0.571 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 6.149E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.648E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 0.164 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 7.565E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.204 | 1.172E-003 | 5.440E-004 | 0.815 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 5.921E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 25675.38772 | 30810.46526 | 2.15990 | 2.59188 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 33.40000 | 6.26594E-003 | 348.38640 | 29.99610 | 0.53091 | 0.00000 |
2 | LGSTORE1 | Heating | 42629.83457 | 51155.80148 | 2.10069 | 2.52083 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 348.38640 | 29.99610 | 0.53091 | 0.00000 |
3 | SMSTORE1 | Cooling | 13500.80993 | 16200.97191 | 1.13573 | 1.36287 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
4 | SMSTORE1 | Heating | 21768.33375 | 26122.00050 | 1.07266 | 1.28719 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
5 | SMSTORE2 | Cooling | 12777.17878 | 15332.61453 | 1.07485 | 1.28982 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
6 | SMSTORE2 | Heating | 21916.83305 | 26300.19966 | 1.07998 | 1.29597 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
7 | SMSTORE3 | Cooling | 12739.39505 | 15287.27405 | 1.07167 | 1.28601 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
8 | SMSTORE3 | Heating | 21972.16655 | 26366.59986 | 1.08270 | 1.29924 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
9 | SMSTORE4 | Cooling | 12690.24550 | 15228.29460 | 1.06754 | 1.28105 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
10 | SMSTORE4 | Heating | 22107.28475 | 26528.74170 | 1.08936 | 1.30723 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
11 | LGSTORE2 | Cooling | 23193.06016 | 27831.67219 | 1.95108 | 2.34130 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 348.38640 | 29.99610 | 0.53091 | 0.00000 |
12 | LGSTORE2 | Heating | 40986.56279 | 49183.87535 | 2.01974 | 2.42368 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 348.38640 | 29.99610 | 0.53091 | 0.00000 |
13 | SMSTORE5 | Cooling | 12117.60722 | 14541.12867 | 1.01937 | 1.22324 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
14 | SMSTORE5 | Heating | 22449.14657 | 26938.97589 | 1.10621 | 1.32745 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
15 | SMSTORE6 | Cooling | 12031.17525 | 14437.41030 | 1.01210 | 1.21452 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
16 | SMSTORE6 | Heating | 22428.25805 | 26913.90966 | 1.10518 | 1.32622 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
17 | SMSTORE7 | Cooling | 11921.23500 | 14305.48200 | 1.00285 | 1.20342 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
18 | SMSTORE7 | Heating | 22636.32959 | 27163.59551 | 1.11543 | 1.33852 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
19 | SMSTORE8 | Cooling | 12051.87844 | 14462.25412 | 1.01384 | 1.21661 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 33.13333 | 6.26594E-003 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
20 | SMSTORE8 | Heating | 25503.83532 | 30604.60238 | 1.25672 | 1.50806 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.26545 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 35760.49 | 2.59188 | 2.59188 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 77773.96 | 2.52083 | 2.52083 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 18665.80 | 1.36287 | 1.36287 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 39422.99 | 1.28719 | 1.28719 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 17808.53 | 1.28982 | 1.28982 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 39598.60 | 1.29597 | 1.29597 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 17763.77 | 1.28601 | 1.28601 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 39664.03 | 1.29924 | 1.29924 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 17705.54 | 1.28105 | 1.28105 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 39823.82 | 1.30723 | 1.30723 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 32819.73 | 2.34130 | 2.34130 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 75830.85 | 2.42368 | 2.42368 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 17027.15 | 1.22324 | 1.22324 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 40228.09 | 1.32745 | 1.32745 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 16924.75 | 1.21452 | 1.21452 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 40203.39 | 1.32622 | 1.32622 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 16794.51 | 1.20342 | 1.20342 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 40449.44 | 1.33852 | 1.33852 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 16930.13 | 1.21661 | 1.21661 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 43840.26 | 1.50806 | 1.50806 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.59188 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.36287 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.29597 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.29924 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.30723 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.42368 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.32745 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.32622 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.33852 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.50806 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.59188 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.59188 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.59188 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.59188 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.59188 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.59188 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.36287 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.36287 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.36287 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.36287 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.36287 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.36287 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.29597 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.29597 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.29597 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.29597 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.29597 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.29597 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.29924 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.29924 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.29924 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.29924 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.29924 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.29924 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.30723 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.30723 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.30723 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.30723 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.30723 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.30723 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.42368 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.42368 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.42368 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.42368 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.42368 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 2.42368 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.32745 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.32745 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.32745 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.32745 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.32745 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 1.32745 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 1.00000 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.32622 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.32622 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.32622 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.32622 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.32622 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 1.32622 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 1.00000 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.33852 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.33852 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.33852 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.33852 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.33852 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 1.33852 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.50806 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.50806 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.50806 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.50806 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.50806 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 1.50806 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 2.59188 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.36287 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.29597 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.29924 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.30723 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 2.42368 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 1.32745 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 1.32622 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 1.33852 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 1.50806 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.59188 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.53091 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.59188 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.59188 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.59188 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.59188 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.59188 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.29594 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.59188 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 42904.81708 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 43301.64000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 21650.82000 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 43301.64000 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79529 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79529 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79529 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79529 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 43301.64000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 79194.79517 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.59188 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2836.83122 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 79194.79517 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.36287 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.36287 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.36287 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.36287 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.36287 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.36287 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.68144 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.36287 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22560.33769 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22648.30000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11324.15000 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 22648.30000 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79723 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79723 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79723 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79723 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22648.30000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 40936.50763 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.36287 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1553.82412 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 40936.50763 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.29597 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.29597 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.29597 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.29597 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.29597 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.29597 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.64799 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.29597 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21452.90515 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21668.70000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10834.35000 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21668.70000 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79499 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79499 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79499 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79499 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21668.70000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 39598.59847 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.29597 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1477.54955 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 39598.59847 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.29924 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.29924 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.29924 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.29924 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.29924 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.29924 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.64962 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.29924 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21507.03526 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21730.74000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10865.37000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21730.74000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79487 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79487 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79487 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79487 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21730.74000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 39664.03232 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.29924 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1481.28015 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 39664.03232 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.30723 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.30723 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.30723 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.30723 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.30723 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.30723 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.65362 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.30723 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21639.29813 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 21874.03000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10937.01500 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21874.03000 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79471 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79471 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79471 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79471 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21874.03000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 39823.81542 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.30723 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1490.39003 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 39823.81542 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.42368 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.53091 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.42368 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.42368 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.42368 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.42368 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.42368 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.21184 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.42368 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 40120.50985 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 40978.42000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 20489.21000 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 40978.42000 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79096 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79096 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79096 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79096 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 40978.42000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 75830.85371 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.42368 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2652.73562 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 75830.85371 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.32745 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.32745 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.32745 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.32745 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.32745 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.32745 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.66373 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.32745 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21974.01093 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22332.29000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11166.14500 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 22332.29000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79276 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79276 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79276 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79276 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22332.29000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 40228.09007 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.32745 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1513.44076 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 40228.09007 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.32622 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.32622 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.32622 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.32622 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.32622 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.32622 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.66311 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.32622 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21953.65006 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22330.57000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11165.28500 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 22330.57000 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79245 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79245 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79245 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79245 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22330.57000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 40203.38873 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.32622 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1512.03245 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 40203.38873 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.33852 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.33852 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.33852 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.33852 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.33852 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.33852 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.66926 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.33852 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22157.25873 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22562.62000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11281.31000 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 22562.62000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79205 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79205 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79205 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79205 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22562.62000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 40449.44076 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.33852 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1526.06072 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 40449.44076 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.50806 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.26545 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.50806 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.50806 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.50806 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.50806 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.50806 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.75403 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.50806 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24963.74772 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 25394.14000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12697.07000 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 25394.14000 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79242 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79242 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79242 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79242 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 25394.14000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 43840.26276 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.50806 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1650.58232 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 43840.26276 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 41270.1 | 9.55 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 21580.2 | 29.22 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 20652.9 | 40.60 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 20712.4 | 50.53 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 20849.4 | 60.24 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 39078.4 | 40.20 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 21291.7 | 87.54 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 21291.0 | 97.61 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 21513.4 | 106.68 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 24212.0 | 104.82 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.199 | 0.190 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.47_SHGC_0.4 | N/A | 2.672 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.514 | 0.477 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.289 | 0.270 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 10 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 4.0784221521E-002 | 0.2401763473 | Pass | Pass | 0.4831795304 | 3.7219889555 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 6.9351599102E-002 | 0.1806571779 | Pass | Pass | 0.6570439087 | 5.3669199287 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 4.3567922519E-002 | 0.2242210344 | Pass | Pass | 0.1507089957 | 0.5611169608 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 4.9449876678E-002 | 0.2735444936 | Pass | Pass | 0.1420991228 | 0.5510133246 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 5.3648770069E-002 | 0.2890879952 | Pass | Pass | 0.1365745012 | 0.5102008145 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 6.6145651420E-002 | 0.3373018106 | Pass | Pass | 5.7765128850E-002 | 0.1566158510 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 6.6181885616E-002 | 0.3407219408 | Pass | Pass | 5.0972172446E-002 | 0.1322189195 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 6.7642717733E-002 | 0.3490738452 | Pass | Pass | 4.8538243791E-002 | 0.1254148668 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 7.3154495342E-002 | 0.3820434011 | Pass | Pass | 4.3095024713E-002 | 0.1107670904 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 0.1157325262 | 0.4366774468 | Pass | Pass | 0.1597251795 | 0.9632239917 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | -27.60 | 0.00 | -27.60 | Wetbulb [C] | 2.70 | 230.00 |
GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 33.40 | 16.00 | 16.30 | Wetbulb [C] | 4.90 | 240.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.477 | 0.514 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.199 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.289 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.672 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.47_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.672 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.672 | 0.394 | 0.401 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.672 | 0.394 | 0.401 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 117.88 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 10.4948 | 348.39 | 3656.25 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 67.52 |
SMSTORE1_LIGHTS | SMSTORE1 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 58.94 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 10.4948 | 174.19 | 1828.13 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 33.76 |
SMSTORE2_LIGHTS | SMSTORE2 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 4.3056 | 174.19 | 750.00 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.98 |
SMSTORE3_LIGHTS | SMSTORE3 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 4.3056 | 174.19 | 750.00 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.98 |
SMSTORE4_LIGHTS | SMSTORE4 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 4.3056 | 174.19 | 750.00 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.98 |
LGSTORE2_LIGHTS | LGSTORE2 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 85.86 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 11.0113 | 4180.64 | 46034.15 | 708.74 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 10625.34 | AstronomicalClock | - | 83.57 | 83.57 | 166.68 | |
Exterior Lighting Total | 10625.34 | 166.68 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 43301.64 | 34437.36 | 8864.28 | 0.80 | 3.30 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22648.30 | 18055.90 | 4592.40 | 0.80 | 3.50 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 21668.70 | 17226.40 | 4442.30 | 0.79 | 3.50 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 21730.74 | 17273.11 | 4457.63 | 0.79 | 3.50 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 21874.03 | 17383.51 | 4490.52 | 0.79 | 3.50 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 40978.42 | 32412.29 | 8566.13 | 0.79 | 3.30 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22332.29 | 17704.15 | 4628.14 | 0.79 | 3.50 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22330.57 | 17695.86 | 4634.71 | 0.79 | 3.50 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22562.62 | 17870.72 | 4691.90 | 0.79 | 3.50 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 25394.14 | 20122.82 | 5271.32 | 0.79 | 3.50 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 41270.1 | 9.55 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 21580.2 | 29.22 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 20652.9 | 40.60 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 20712.4 | 50.53 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 20849.4 | 60.24 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 39078.4 | 40.20 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 21291.7 | 87.54 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 21291.0 | 97.61 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 21513.4 | 106.68 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 24212.0 | 104.82 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 79194.80 | 0.79 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 40936.51 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 39598.60 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 39664.03 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 39823.82 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 75830.85 | 0.79 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 40228.09 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 40203.39 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 40449.44 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 43840.26 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 2.59 | 2836.83 | 1094.51 | 1.00 | 1.25 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.36 | 1553.82 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.30 | 1477.55 | 1140.11 | 1.00 | 1.31 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.30 | 1481.28 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.31 | 1490.39 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 2.42 | 2652.74 | 1094.51 | 1.00 | 1.26 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.33 | 1513.44 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.33 | 1512.03 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.34 | 1526.06 | 1140.11 | 1.00 | 1.30 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 1.51 | 1650.58 | 1094.51 | 1.00 | 1.33 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 25675.39 | 30810.47 | 88.44 | 2.160 | 2.592 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 23.89 | 23.89 | 0.00711 | 33.40 | 0.00627 | 0.531 | 0.00 |
SMSTORE1 | 13500.81 | 16200.97 | 93.01 | 1.136 | 1.363 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00709 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE2 | 12777.18 | 15332.61 | 88.02 | 1.075 | 1.290 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00709 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE3 | 12739.40 | 15287.27 | 87.76 | 1.072 | 1.286 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00709 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE4 | 12690.25 | 15228.29 | 87.42 | 1.068 | 1.281 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00709 | 33.40 | 0.00627 | 0.265 | 0.00 |
LGSTORE2 | 23193.06 | 27831.67 | 79.89 | 1.951 | 2.341 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00712 | 33.40 | 0.00627 | 0.531 | 0.00 |
SMSTORE5 | 12117.61 | 14541.13 | 83.48 | 1.019 | 1.223 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00710 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE6 | 12031.18 | 14437.41 | 82.88 | 1.012 | 1.215 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00710 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE7 | 11921.23 | 14305.48 | 82.12 | 1.003 | 1.203 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 23.89 | 23.89 | 0.00710 | 33.40 | 0.00627 | 0.265 | 0.00 |
SMSTORE8 | 12051.88 | 14462.25 | 83.02 | 1.014 | 1.217 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 23.89 | 23.89 | 0.00709 | 33.13 | 0.00627 | 0.265 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 42629.83 | 51155.80 | 146.84 | 2.101 | 2.521 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00658 | -27.60 | 0.00034 | 0.531 | 0.00 |
SMSTORE1 | 21768.33 | 26122.00 | 149.96 | 1.073 | 1.287 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00646 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE2 | 21916.83 | 26300.20 | 150.98 | 1.080 | 1.296 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00647 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE3 | 21972.17 | 26366.60 | 151.36 | 1.083 | 1.299 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00647 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE4 | 22107.28 | 26528.74 | 152.29 | 1.089 | 1.307 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00648 | -27.60 | 0.00034 | 0.265 | 0.00 |
LGSTORE2 | 40986.56 | 49183.88 | 141.18 | 2.020 | 2.424 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00655 | -27.60 | 0.00034 | 0.531 | 0.00 |
SMSTORE5 | 22449.15 | 26938.98 | 154.65 | 1.106 | 1.327 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00650 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE6 | 22428.26 | 26913.91 | 154.51 | 1.105 | 1.326 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00650 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE7 | 22636.33 | 27163.60 | 155.94 | 1.115 | 1.339 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00651 | -27.60 | 0.00034 | 0.265 | 0.00 |
SMSTORE8 | 25503.84 | 30604.60 | 175.69 | 1.257 | 1.508 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00662 | -27.60 | 0.00034 | 0.265 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 2.59 | 2.59 | 2.52 | 2.52 | 2.5919 | 2.5919 | 2.5919 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.36 | 1.36 | 1.29 | 1.29 | 1.3629 | 1.3629 | 1.3629 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.29 | 1.29 | 1.30 | 1.30 | 1.2960 | 1.2960 | 1.2960 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 1.29 | 1.29 | 1.30 | 1.30 | 1.2992 | 1.2992 | 1.2992 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.28 | 1.28 | 1.31 | 1.31 | 1.3072 | 1.3072 | 1.3072 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 2.34 | 2.34 | 2.42 | 2.42 | 2.4237 | 2.4237 | 2.4237 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 1.22 | 1.22 | 1.33 | 1.33 | 1.3275 | 1.3275 | 1.3275 | 1.0000 | 1.0000 |
PSZ-AC_8:8 | 1.21 | 1.21 | 1.33 | 1.33 | 1.3262 | 1.3262 | 1.3262 | 1.0000 | 1.0000 |
PSZ-AC_9:9 | 1.20 | 1.20 | 1.34 | 1.34 | 1.3385 | 1.3385 | 1.3385 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 1.22 | 1.22 | 1.51 | 1.51 | 1.5081 | 1.5081 | 1.5081 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 43301.640 | 0.000 | 2.591880 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 43301.64 | 43301.64 | 2.591880 | 25.84 | 14.31 | 0.00693477 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.4835 | 23.89 | 0.00710706 | 33.7571 | 25675.39 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 79194.795 | 79194.795 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 79194.80 | 79194.80 | 2.591884 | 10.85 | 6.68 | 0.00526758 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.4835 | 21.10 | 0.00658174 | 37.0694 | 42629.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 22648.300 | 0.000 | 1.362870 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22648.30 | 22648.30 | 1.362870 | 25.74 | 14.27 | 0.00692866 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.4776 | 23.89 | 0.00708896 | 33.6720 | 13500.81 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 40936.508 | 40936.508 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40936.51 | 40936.51 | 1.362872 | 11.06 | 6.71 | 0.00520103 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.4775 | 21.10 | 0.00646346 | 36.4119 | 21768.33 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 21668.700 | 0.000 | 1.295970 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21668.70 | 21668.70 | 1.295970 | 25.85 | 14.30 | 0.00692291 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.4830 | 23.89 | 0.00709316 | 33.6917 | 12777.18 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 39598.598 | 39598.598 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39598.60 | 39598.60 | 1.295971 | 11.13 | 6.75 | 0.00521599 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.4830 | 21.10 | 0.00647152 | 36.4569 | 21916.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 21730.740 | 0.000 | 1.299240 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21730.74 | 21730.74 | 1.299240 | 25.85 | 14.31 | 0.00692259 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.4315 | 23.89 | 0.00709339 | 33.6928 | 12739.40 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 39664.032 | 39664.032 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39664.03 | 39664.03 | 1.299243 | 11.15 | 6.77 | 0.00522152 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.4314 | 21.10 | 0.00647450 | 36.4735 | 21972.17 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 21874.030 | 0.000 | 1.307230 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21874.03 | 21874.03 | 1.307230 | 25.86 | 14.31 | 0.00692217 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.3066 | 23.89 | 0.00709370 | 33.6942 | 12690.25 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 39823.815 | 39823.815 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39823.82 | 39823.82 | 1.307234 | 11.21 | 6.81 | 0.00523491 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.3065 | 21.10 | 0.00648169 | 36.5136 | 22107.28 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 40978.420 | 0.000 | 2.423680 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 40978.42 | 40978.42 | 2.423680 | 26.05 | 14.38 | 0.00692621 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 21.9050 | 23.89 | 0.00711983 | 33.8171 | 23193.06 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 75830.854 | 75830.854 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 75830.85 | 75830.85 | 2.423684 | 10.43 | 6.41 | 0.00519305 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 21.9050 | 21.10 | 0.00655376 | 36.9131 | 40986.56 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 22332.290 | 0.000 | 1.327450 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22332.29 | 22332.29 | 1.327450 | 25.95 | 14.34 | 0.00691693 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.9973 | 23.89 | 0.00709736 | 33.7114 | 12117.61 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 40228.090 | 40228.090 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40228.09 | 40228.09 | 1.327452 | 11.36 | 6.92 | 0.00526808 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.9973 | 21.10 | 0.00649941 | 36.6124 | 22449.15 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 22330.570 | 0.000 | 1.326220 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22330.57 | 22330.57 | 1.326220 | 25.97 | 14.34 | 0.00691609 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.0158 | 23.89 | 0.00709793 | 33.7141 | 12031.18 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 40203.389 | 40203.389 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40203.39 | 40203.39 | 1.326216 | 11.35 | 6.91 | 0.00526606 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.0159 | 21.10 | 0.00649832 | 36.6062 | 22428.26 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 22562.620 | 0.000 | 1.338520 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22562.62 | 22562.62 | 1.338520 | 25.99 | 14.35 | 0.00691499 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.8319 | 23.89 | 0.00709868 | 33.7176 | 11921.23 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 40449.441 | 40449.441 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40449.44 | 40449.44 | 1.338521 | 11.44 | 6.98 | 0.00528601 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.8319 | 21.10 | 0.00650908 | 36.6662 | 22636.33 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 25394.140 | 0.000 | 1.508060 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 25394.14 | 25394.14 | 1.508060 | 25.97 | 14.34 | 0.00691137 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 17.6023 | 23.89 | 0.00709195 | 33.6859 | 12035.72 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 43840.263 | 43840.263 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 43840.26 | 43840.26 | 1.508062 | 12.53 | 7.71 | 0.00551301 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 17.6023 | 21.10 | 0.00661770 | 37.2723 | 25503.84 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 43301.640 | 0.000 | 2.591880 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7314 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 43301.64 | 43301.64 | 1.0000 | 2.72961219 | 2.591880 | 25.84 | 14.31 | 0.00693477 | 43639.1 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 43301.64 | 33.40 | 0.00626594 | 16.30 | 0.53090778 | 20.4835 | 23.89 | 0.00710706 | 23.89 | 0.00710706 | 33.7571 | 25675.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 79194.795 | 79194.795 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.591884 | 2.72961635 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 79194.80 | 79194.80 | 1.0000 | 2.72961635 | 2.591884 | 10.85 | 6.68 | 0.00526758 | 24178.5 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 79194.80 | -27.60 | 0.00034190 | -27.60 | 0.53090778 | 20.4835 | 21.10 | 0.00658174 | 21.10 | 0.00658174 | 37.0694 | 42629.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 22648.300 | 0.000 | 1.362870 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7200 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22648.30 | 22648.30 | 1.0000 | 1.43529275 | 1.362870 | 25.74 | 14.27 | 0.00692866 | 43526.3 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22648.30 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 19.4776 | 23.89 | 0.00708896 | 23.89 | 0.00708896 | 33.6720 | 13500.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 40936.508 | 40936.508 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.362872 | 1.43529510 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40936.51 | 40936.51 | 1.0000 | 1.43529510 | 1.362872 | 11.06 | 6.71 | 0.00520103 | 24226.7 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40936.51 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 19.4775 | 21.10 | 0.00646346 | 21.10 | 0.00646346 | 36.4119 | 21768.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21668.700 | 0.000 | 1.295970 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7094 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21668.70 | 21668.70 | 1.0000 | 1.36483769 | 1.295970 | 25.85 | 14.30 | 0.00692291 | 43618.4 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21668.70 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 20.4830 | 23.89 | 0.00709316 | 23.89 | 0.00709316 | 33.6917 | 12777.18 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 39598.598 | 39598.598 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.295971 | 1.36483892 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39598.60 | 39598.60 | 1.0000 | 1.36483892 | 1.295971 | 11.13 | 6.75 | 0.00521599 | 24333.5 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39598.60 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 20.4830 | 21.10 | 0.00647152 | 21.10 | 0.00647152 | 36.4569 | 21916.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21730.740 | 0.000 | 1.299240 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7088 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21730.74 | 21730.74 | 1.0000 | 1.36828146 | 1.299240 | 25.85 | 14.31 | 0.00692259 | 43623.5 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21730.74 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 20.4315 | 23.89 | 0.00709339 | 23.89 | 0.00709339 | 33.6928 | 12739.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 39664.032 | 39664.032 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.299243 | 1.36828494 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39664.03 | 39664.03 | 1.0000 | 1.36828494 | 1.299243 | 11.15 | 6.77 | 0.00522152 | 24373.0 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39664.03 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 20.4314 | 21.10 | 0.00647450 | 21.10 | 0.00647450 | 36.4735 | 21972.17 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21874.030 | 0.000 | 1.307230 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7080 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 21874.03 | 21874.03 | 1.0000 | 1.37669605 | 1.307230 | 25.86 | 14.31 | 0.00692217 | 43630.2 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21874.03 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 20.3066 | 23.89 | 0.00709370 | 23.89 | 0.00709370 | 33.6942 | 12690.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 39823.815 | 39823.815 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.307234 | 1.37669990 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39823.82 | 39823.82 | 1.0000 | 1.37669990 | 1.307234 | 11.21 | 6.81 | 0.00523491 | 24468.4 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39823.82 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 20.3065 | 21.10 | 0.00648169 | 21.10 | 0.00648169 | 36.5136 | 22107.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 40978.420 | 0.000 | 2.423680 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.7155 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 40978.42 | 40978.42 | 1.0000 | 2.55247406 | 2.423680 | 26.05 | 14.38 | 0.00692621 | 43829.5 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40978.42 | 33.40 | 0.00626594 | 16.30 | 0.53090778 | 21.9050 | 23.89 | 0.00711983 | 23.89 | 0.00711983 | 33.8171 | 23193.06 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 75830.854 | 75830.854 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.423684 | 2.55247843 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 75830.85 | 75830.85 | 1.0000 | 2.55247843 | 2.423684 | 10.43 | 6.41 | 0.00519305 | 23573.7 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 75830.85 | -27.60 | 0.00034190 | -27.60 | 0.53090778 | 21.9050 | 21.10 | 0.00655376 | 21.10 | 0.00655376 | 36.9131 | 40986.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 22332.290 | 0.000 | 1.327450 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.6982 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22332.29 | 22332.29 | 1.0000 | 1.39799053 | 1.327450 | 25.95 | 14.34 | 0.00691693 | 43711.6 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22332.29 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 19.9973 | 23.89 | 0.00709736 | 23.89 | 0.00709736 | 33.7114 | 12117.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 40228.090 | 40228.090 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.327452 | 1.39799228 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40228.09 | 40228.09 | 1.0000 | 1.39799228 | 1.327452 | 11.36 | 6.92 | 0.00526808 | 24705.0 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40228.09 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 19.9973 | 21.10 | 0.00649941 | 21.10 | 0.00649941 | 36.6124 | 22449.15 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 22330.570 | 0.000 | 1.326220 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.6967 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22330.57 | 22330.57 | 1.0000 | 1.39669517 | 1.326220 | 25.97 | 14.34 | 0.00691609 | 43724.5 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22330.57 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 20.0158 | 23.89 | 0.00709793 | 23.89 | 0.00709793 | 33.7141 | 12031.18 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 40203.389 | 40203.389 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.326216 | 1.39669140 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40203.39 | 40203.39 | 1.0000 | 1.39669140 | 1.326216 | 11.35 | 6.91 | 0.00526606 | 24690.6 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40203.39 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 20.0159 | 21.10 | 0.00649832 | 21.10 | 0.00649832 | 36.6062 | 22428.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 22562.620 | 0.000 | 1.338520 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.6946 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 22562.62 | 22562.62 | 1.0000 | 1.40964879 | 1.338520 | 25.99 | 14.35 | 0.00691499 | 43741.2 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22562.62 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 19.8319 | 23.89 | 0.00709868 | 23.89 | 0.00709868 | 33.7176 | 11921.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 40449.441 | 40449.441 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.338521 | 1.40964956 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40449.44 | 40449.44 | 1.0000 | 1.40964956 | 1.338521 | 11.44 | 6.98 | 0.00528601 | 24831.9 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40449.44 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 19.8319 | 21.10 | 0.00650908 | 21.10 | 0.00650908 | 36.6662 | 22636.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 25394.140 | 0.000 | 1.508060 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.6879 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 25394.14 | 25394.14 | 1.0000 | 1.58819813 | 1.508060 | 25.97 | 14.34 | 0.00691137 | 43711.7 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25394.14 | 33.40 | 0.00626594 | 16.30 | 0.26545389 | 17.6023 | 23.89 | 0.00709181 | 23.89 | 0.00709195 | 33.6859 | 12035.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 43840.263 | 43840.263 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.508062 | 1.58820040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 43840.26 | 43840.26 | 1.0000 | 1.58820040 | 1.508062 | 12.53 | 7.71 | 0.00551301 | 26506.5 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 43840.26 | -27.60 | 0.00034190 | -27.60 | 0.26545389 | 17.6023 | 21.10 | 0.00661770 | 21.10 | 0.00661770 | 37.2723 | 25503.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC_1:1_OA_CONTROLLER | DifferentialDryBulb | 0.53 | 2.59 | - | |||
PSZ-AC_2:2_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.36 | - | |||
PSZ-AC_3:3_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.30 | - | |||
PSZ-AC_4:4_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.30 | - | |||
PSZ-AC_5:5_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.31 | - | |||
PSZ-AC_6:6_OA_CONTROLLER | DifferentialDryBulb | 0.53 | 2.42 | - | |||
PSZ-AC_7:7_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.33 | - | |||
PSZ-AC_8:8_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.33 | - | |||
PSZ-AC_9:9_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.34 | - | |||
PSZ-AC_10:10_OA_CONTROLLER | DifferentialDryBulb | 0.27 | 1.51 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 2437.50 | 3835.33 | 1304.00 |
SMSTORE1 | 1791.17 | 3738.17 | 810.33 |
SMSTORE2 | 1748.33 | 2966.17 | 1004.83 |
SMSTORE3 | 1850.33 | 3017.33 | 1125.17 |
SMSTORE4 | 1920.17 | 3054.17 | 1218.33 |
LGSTORE2 | 1911.17 | 2862.50 | 1316.50 |
SMSTORE5 | 1840.83 | 2899.33 | 1338.33 |
SMSTORE6 | 1852.50 | 2923.67 | 1376.50 |
SMSTORE7 | 1938.17 | 2977.00 | 1495.83 |
SMSTORE8 | 2244.33 | 3102.67 | 1860.17 |
Facility | 3575.67 | 4468.83 | 2403.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 17.00 | 0.00 | 3.00 | 0.00 |
SMSTORE1 | 5.17 | 0.00 | 1.33 | 0.00 |
SMSTORE2 | 3.00 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 5.83 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 7.33 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 15.33 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 13.83 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 13.83 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 18.17 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 113.50 | 0.00 | 0.00 | 0.00 |
Facility | 139.00 | 0.00 | 3.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 1.457 | 0.398 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 1.266 | 0.425 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 1.427 | 0.552 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 1.417 | 0.552 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 1.407 | 0.552 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 1.372 | 0.517 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 1.407 | 0.587 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 1.400 | 0.587 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 1.384 | 0.587 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 1.386 | 0.634 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 1.037 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 1.037 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 1.037 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 1.039 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 1.039 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 1.039 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 1.039 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 1.039 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
Electricity:Building | 837.46 | 2751.13 | 01-JAN-00:10 | 51821.98 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 211.76 | 576.88 | 01-JAN-00:10 | 10885.83 | 01-JAN-10:10 |
InteriorLights:Electricity | 708.74 | 2301.71 | 01-JAN-00:10 | 43732.45 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 185.40 | 501.98 | 01-JAN-00:10 | 9537.57 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 708.74 | 2301.71 | 01-JAN-00:10 | 43732.45 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 105.88 | 288.44 | 01-JAN-00:10 | 5442.91 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 92.70 | 250.99 | 01-JAN-00:10 | 4768.79 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 68.15 | 234.53 | 01-JAN-00:10 | 4418.69 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 57.68 | 197.08 | 01-JAN-00:10 | 3744.57 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 68.15 | 234.53 | 01-JAN-00:10 | 4418.69 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 57.68 | 197.08 | 01-JAN-00:10 | 3744.57 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 68.15 | 234.53 | 01-JAN-00:10 | 4418.69 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 57.68 | 197.08 | 01-JAN-00:10 | 3744.57 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 105.13 | 394.07 | 01-JAN-00:10 | 7412.39 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 85.86 | 319.16 | 01-JAN-00:10 | 6064.13 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
Electricity:Plant | 66.08 | 1218.00 | 05-JAN-07:10 | 15683.58 | 12-DEC-14:10 |
WaterSystems:Electricity | 66.08 | 1218.00 | 05-JAN-07:10 | 15683.58 | 12-DEC-14:10 |
Water Heater:WaterSystems:Electricity | 66.08 | 1218.00 | 05-JAN-07:10 | 15683.58 | 12-DEC-14:10 |
ElectricityPurchased:Facility | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
ElectricityPurchased:Plant | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
Cogeneration:ElectricityPurchased | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
ElectricityNet:Plant | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
Cogeneration:ElectricityNet | 1460.16 | 3969.13 | 20-FEB-07:30 | 139349.83 | 17-JUL-16:00 |
Electricity:HVAC | 389.94 | 0.00 | 01-JAN-00:10 | 82082.21 | 17-JUL-16:00 |
Fans:Electricity | 304.59 | 0.00 | 01-JAN-00:10 | 17694.73 | 24-FEB-10:10 |
General:Fans:Electricity | 304.59 | 0.00 | 01-JAN-00:10 | 17694.73 | 24-FEB-10:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 85.35 | 0.00 | 01-JAN-00:10 | 64387.48 | 17-JUL-16:00 |
ExteriorLights:Electricity | 166.68 | 0.00 | 01-JAN-08:20 | 10625.34 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 166.68 | 0.00 | 01-JAN-08:20 | 10625.34 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 879.76 | 0.00 | 01-JAN-00:10 | 438828.41 | 08-JAN-18:00 |
Gas:HVAC | 879.76 | 0.00 | 01-JAN-00:10 | 438828.41 | 08-JAN-18:00 |
Heating:Gas | 879.76 | 0.00 | 01-JAN-00:10 | 438828.41 | 08-JAN-18:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1635.97 | 0.00 | 01-JAN-00:10 | 554826.38 | 08-JAN-18:00 |
EnergyTransfer:Building | 660.19 | 0.00 | 01-JAN-00:10 | 209501.67 | 28-JAN-08:10 |
EnergyTransfer:Zone:LGSTORE1 | 132.82 | 0.00 | 01-JAN-00:10 | 40187.53 | 28-JAN-08:10 |
Heating:EnergyTransfer | 323.76 | 0.00 | 01-JAN-00:10 | 209501.67 | 28-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 42.37 | 0.00 | 01-JAN-00:10 | 40187.53 | 28-JAN-08:10 |
Cooling:EnergyTransfer | 336.44 | 0.00 | 01-JAN-00:10 | 122588.34 | 17-JUL-16:10 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 90.45 | 0.00 | 01-JAN-00:10 | 21341.62 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE1 | 63.92 | 0.00 | 01-JAN-00:10 | 19008.22 | 28-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 16.99 | 0.00 | 01-JAN-00:10 | 19008.22 | 28-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 46.92 | 0.00 | 01-JAN-00:10 | 13189.56 | 27-JUL-20:20 |
EnergyTransfer:Zone:SMSTORE2 | 50.75 | 0.00 | 01-JAN-00:10 | 18882.41 | 29-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 22.41 | 0.00 | 01-JAN-00:10 | 18882.41 | 29-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 28.34 | 0.00 | 01-JAN-00:10 | 10471.27 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE3 | 51.24 | 0.00 | 01-JAN-00:10 | 20130.60 | 31-DEC-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 24.30 | 0.00 | 01-JAN-00:10 | 20130.60 | 31-DEC-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 26.95 | 0.00 | 01-JAN-00:10 | 10468.35 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE4 | 51.64 | 0.00 | 01-JAN-00:10 | 20297.76 | 31-DEC-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 26.24 | 0.00 | 01-JAN-00:10 | 20297.76 | 31-DEC-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 25.41 | 0.00 | 01-JAN-00:10 | 10402.51 | 17-JUL-16:10 |
EnergyTransfer:Zone:LGSTORE2 | 92.78 | 0.00 | 01-JAN-00:10 | 37482.67 | 31-DEC-09:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 50.45 | 0.00 | 01-JAN-00:10 | 37482.67 | 31-DEC-09:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 42.32 | 0.00 | 01-JAN-00:10 | 18926.32 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE5 | 49.75 | 0.00 | 01-JAN-00:10 | 19865.67 | 28-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 28.78 | 0.00 | 01-JAN-00:10 | 19865.67 | 28-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 20.96 | 0.00 | 01-JAN-00:10 | 10044.27 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE6 | 49.68 | 0.00 | 01-JAN-00:10 | 19886.54 | 08-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 29.33 | 0.00 | 01-JAN-00:10 | 19886.54 | 08-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 20.34 | 0.00 | 01-JAN-00:10 | 9975.44 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE7 | 50.81 | 0.00 | 01-JAN-00:10 | 20814.55 | 08-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 32.08 | 0.00 | 01-JAN-00:10 | 20814.55 | 08-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 18.73 | 0.00 | 01-JAN-00:10 | 9879.40 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE8 | 66.82 | 0.00 | 01-JAN-00:10 | 25040.18 | 11-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 50.81 | 0.00 | 01-JAN-00:10 | 25040.18 | 11-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 16.01 | 0.00 | 01-JAN-00:10 | 10147.79 | 17-JUL-16:10 |
EnergyTransfer:HVAC | 975.78 | 0.00 | 01-JAN-00:10 | 350020.50 | 08-JAN-18:00 |
HeatingCoils:EnergyTransfer | 701.62 | 0.00 | 01-JAN-00:10 | 350020.50 | 08-JAN-18:00 |
CoolingCoils:EnergyTransfer | 274.16 | 0.00 | 01-JAN-00:10 | 184997.48 | 17-JUL-16:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 42.368 | -90.450 | 0.000 | 0.000 | 13.531 | 185.400 | 26.357 | 22.296 | 0.000 | 2.819 | 0.001 | 0.000 | -15.842 | 0.000 | -73.311 | -113.167 |
SMSTORE1 | 0.000 | 0.000 | 16.994 | -46.922 | 0.000 | 0.000 | 6.682 | 92.700 | 13.179 | 11.043 | 0.000 | 1.551 | 0.002 | 0.000 | -8.255 | 0.000 | -35.445 | -51.526 |
SMSTORE2 | 0.000 | 0.000 | 22.408 | -28.338 | 0.000 | 0.000 | 4.084 | 57.682 | 10.467 | 11.060 | 0.000 | 1.514 | 0.000 | 0.000 | -7.991 | 0.000 | -36.311 | -34.574 |
SMSTORE3 | 0.000 | 0.000 | 24.295 | -26.947 | 0.000 | 0.000 | 4.091 | 57.682 | 10.467 | 11.086 | 0.000 | 1.514 | 0.001 | 0.000 | -7.882 | 0.000 | -36.126 | -38.180 |
SMSTORE4 | 0.000 | 0.000 | 26.235 | -25.409 | 0.000 | 0.000 | 4.096 | 57.682 | 10.467 | 11.109 | 0.000 | 1.514 | 0.000 | 0.000 | -7.812 | 0.000 | -35.992 | -41.891 |
LGSTORE2 | 0.000 | 0.000 | 50.455 | -42.323 | 0.000 | 0.000 | 14.079 | 85.864 | 19.261 | 22.376 | 0.000 | 2.668 | 0.005 | 0.000 | -15.193 | 0.000 | -65.297 | -71.890 |
SMSTORE5 | 0.000 | 0.000 | 28.782 | -20.963 | 0.000 | 0.000 | 7.039 | 42.932 | 9.631 | 11.169 | 0.000 | 1.517 | 0.001 | 0.000 | -7.625 | 0.000 | -36.119 | -36.364 |
SMSTORE6 | 0.000 | 0.000 | 29.332 | -20.343 | 0.000 | 0.000 | 7.043 | 42.932 | 9.631 | 11.181 | 0.000 | 1.517 | 0.003 | 0.000 | -7.595 | 0.000 | -36.064 | -37.635 |
SMSTORE7 | 0.000 | 0.000 | 32.076 | -18.730 | 0.000 | 0.000 | 7.055 | 42.932 | 9.631 | 11.217 | 0.000 | 1.518 | 0.004 | 0.000 | -7.484 | 0.000 | -35.867 | -42.346 |
SMSTORE8 | 0.000 | 0.000 | 50.812 | -16.009 | 0.000 | 0.000 | 7.079 | 42.932 | 9.631 | 11.331 | 0.000 | 1.608 | 0.004 | 0.000 | -7.012 | 0.000 | -46.597 | -53.776 |
Total Facility | 0.000 | 0.000 | 323.757 | -336.435 | 0.000 | 0.000 | 74.780 | 708.738 | 128.721 | 133.868 | 0.000 | 17.740 | 0.022 | 0.000 | -92.690 | 0.000 | -437.129 | -521.350 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -42461.38 | 0.00 | 0.00 | 94.03 | 501.98 | 74.90 | 0.00 | 0.00 | 0.00 | 42258.21 | 0.00 | -70.30 | 0.00 | -397.45 | 0.00 |
SMSTORE1 | 14-AUG-20:40 | 0.00 | 0.00 | 0.00 | -26167.12 | 0.00 | 0.00 | 343.15 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 20651.33 | 0.00 | -217.51 | 0.00 | -52.76 | 0.00 |
SMSTORE2 | 27-JUL-06:01 | 0.00 | 0.00 | 0.00 | -23256.99 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 23250.44 | 0.00 | -175.74 | 0.00 | -52.24 | 0.00 |
SMSTORE3 | 27-JUL-06:01 | 0.00 | 0.00 | 0.00 | -23393.53 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 23387.15 | 0.00 | -175.91 | 0.00 | -52.24 | 0.00 |
SMSTORE4 | 07-AUG-06:02 | 0.00 | 0.00 | 0.00 | -23082.32 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 22968.72 | 0.00 | -92.28 | 0.00 | -28.65 | 0.00 |
LGSTORE2 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -41320.86 | 0.00 | 0.00 | 0.00 | 319.16 | 74.90 | 0.00 | 0.00 | 0.00 | 41408.72 | 0.00 | -90.19 | 0.00 | -391.73 | 0.00 |
SMSTORE5 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -22365.98 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 22428.14 | 0.00 | -44.86 | 0.00 | -214.33 | 0.00 |
SMSTORE6 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -22304.89 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 22364.33 | 0.00 | -43.79 | 0.00 | -212.69 | 0.00 |
SMSTORE7 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -22337.18 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 22387.75 | 0.00 | -40.90 | 0.00 | -206.71 | 0.00 |
SMSTORE8 | 04-SEP-08:62 | 0.00 | 0.00 | 0.00 | -18532.36 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 349.22 | 0.00 | 94.08 | 17892.03 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -198248.86 | 0.00 | 0.00 | 297.85 | 7622.93 | 1460.61 | 0.00 | 0.00 | 0.00 | 191733.52 | 0.00 | -415.32 | 0.00 | -2450.73 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 29-JAN-08:61 | 0.00 | 0.00 | 78996.81 | 0.00 | 0.00 | 0.00 | 152.07 | 501.98 | 74.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1912.63 | 0.00 | -3925.07 | -73888.06 |
SMSTORE1 | 27-JAN-08:61 | 0.00 | 0.00 | 40759.08 | 0.00 | 0.00 | 0.00 | 0.00 | 250.99 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -922.74 | 0.00 | -2101.95 | -38022.83 |
SMSTORE2 | 08-JAN-08:61 | 0.00 | 0.00 | 39495.39 | 0.00 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -883.70 | 0.00 | -1789.16 | -37057.06 |
SMSTORE3 | 05-FEB-08:61 | 0.00 | 0.00 | 39576.75 | 0.00 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -431.59 | 0.00 | -1617.86 | -37761.85 |
SMSTORE4 | 29-JAN-08:61 | 0.00 | 0.00 | 39722.82 | 0.00 | 0.00 | 0.00 | 0.00 | 197.08 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -958.65 | 0.00 | -2070.98 | -36927.72 |
LGSTORE2 | 31-DEC-09:01 | 0.00 | 0.00 | 75832.01 | 0.00 | 0.00 | 0.00 | 0.00 | 319.16 | 74.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -955.23 | 0.00 | -3535.82 | -71735.02 |
SMSTORE5 | 29-JAN-09:01 | 0.00 | 0.00 | 40183.96 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 765.68 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1841.04 | -39305.64 |
SMSTORE6 | 29-JAN-09:01 | 0.00 | 0.00 | 40162.27 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 765.91 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1840.97 | -39284.24 |
SMSTORE7 | 27-JAN-08:61 | 0.00 | 0.00 | 40402.41 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -900.07 | 0.00 | -2092.80 | -37606.57 |
SMSTORE8 | 11-JAN-01:11 | 0.00 | 0.00 | 43988.23 | 0.00 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -998.27 | 0.00 | -1879.49 | -41307.51 |
Total Facility | 09-JAN-08:61 | 0.00 | 0.00 | 391667.77 | 0.00 | 0.00 | 0.00 | 416.62 | 7622.93 | 1460.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -11003.02 | 0.00 | -21876.05 | -368288.87 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.5919 | 0.0000 | 29.9961 | 1.0000 | 0.5309 | 2.5919 | 0.2048 | 1.0000 | 0.5309 | 0.2048 | ||
PSZ-AC_2:2 | 1.3629 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3629 | 0.1948 | 1.0000 | 0.2655 | 0.1948 | ||
PSZ-AC_3:3 | 1.2960 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.2960 | 0.2058 | 1.0000 | 0.2655 | 0.2048 | ||
PSZ-AC_4:4 | 1.2992 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.2992 | 0.2064 | 1.0000 | 0.2655 | 0.2043 | ||
PSZ-AC_5:5 | 1.3072 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3072 | 0.2072 | 1.0000 | 0.2655 | 0.2031 | ||
PSZ-AC_6:6 | 2.4237 | 0.0000 | 29.9961 | 1.0000 | 0.5309 | 2.4237 | 0.2268 | 1.0000 | 0.5309 | 0.2190 | ||
PSZ-AC_7:7 | 1.3275 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3275 | 0.2170 | 1.0000 | 0.2655 | 0.2000 | ||
PSZ-AC_8:8 | 1.3262 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3262 | 0.2186 | 1.0000 | 0.2655 | 0.2002 | ||
PSZ-AC_9:9 | 1.3385 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3385 | 0.2206 | 1.0000 | 0.2655 | 0.1983 | ||
PSZ-AC_10:10 | 1.5081 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.5081 | 0.2182 | 1.0000 | 0.2655 | 0.1760 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.5919 | 0.0000 | 29.9961 | 1.0000 | 0.5309 | 2.5919 | 1.0000 | 1.0000 | 0.5309 | 0.2048 | ||
PSZ-AC_2:2 | 1.3629 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3629 | 1.0000 | 1.0000 | 0.2655 | 0.1948 | ||
PSZ-AC_3:3 | 1.2960 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.2960 | 1.0000 | 1.0000 | 0.2655 | 0.2048 | ||
PSZ-AC_4:4 | 1.2992 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.2992 | 1.0000 | 1.0000 | 0.2655 | 0.2043 | ||
PSZ-AC_5:5 | 1.3072 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3072 | 1.0000 | 1.0000 | 0.2655 | 0.2031 | ||
PSZ-AC_6:6 | 2.4237 | 0.0000 | 29.9961 | 1.0000 | 0.5309 | 2.4237 | 1.0000 | 1.0000 | 0.5309 | 0.2190 | ||
PSZ-AC_7:7 | 1.3275 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3275 | 1.0000 | 1.0000 | 0.2655 | 0.2000 | ||
PSZ-AC_8:8 | 1.3262 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3262 | 1.0000 | 1.0000 | 0.2655 | 0.2002 | ||
PSZ-AC_9:9 | 1.3385 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.3385 | 1.0000 | 1.0000 | 0.2655 | 0.1983 | ||
PSZ-AC_10:10 | 1.5081 | 0.0000 | 14.9980 | 1.0000 | 0.2655 | 1.5081 | 1.0000 | 1.0000 | 0.2655 | 0.1760 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001524 | 348.39 | 0.5309 | 1.0000 | 0.5309 | 1.000 | 0.5309 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001524 | 348.39 | 0.5309 | 1.0000 | 0.5309 | 1.000 | 0.5309 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001524 | 174.19 | 0.2655 | 1.0000 | 0.2655 | 1.000 | 0.2655 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001524 | 348.3864 | 0.5309 | 0.5309 | 0.5309 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001524 | 348.3864 | 0.5309 | 0.5309 | 0.5309 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001524 | 174.1932 | 0.2655 | 0.2655 | 0.2655 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.5919 | 2.5919 | 2.5919 | 0.5309 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.3629 | 1.3629 | 1.3629 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.2960 | 1.2960 | 1.2960 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.2992 | 1.2992 | 1.2992 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.3072 | 1.3072 | 1.3072 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 2.4237 | 2.4237 | 2.4237 | 0.5309 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.3275 | 1.3275 | 1.3275 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.3262 | 1.3262 | 1.3262 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.3385 | 1.3385 | 1.3385 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.5081 | 1.5081 | 1.5081 | 0.2655 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.5919 | 2.5919 | 2.5919 | 2.5919 | 0.5309 | 1.0000 |
PSZ-AC_2:2 | 1.3629 | 1.3629 | 1.3629 | 1.3629 | 0.2655 | 1.0000 |
PSZ-AC_3:3 | 1.2960 | 1.2960 | 1.2960 | 1.2960 | 0.2655 | 1.0000 |
PSZ-AC_4:4 | 1.2992 | 1.2992 | 1.2992 | 1.2992 | 0.2655 | 1.0000 |
PSZ-AC_5:5 | 1.3072 | 1.3072 | 1.3072 | 1.3072 | 0.2655 | 1.0000 |
PSZ-AC_6:6 | 2.4237 | 2.4237 | 2.4237 | 2.4237 | 0.5309 | 1.0000 |
PSZ-AC_7:7 | 1.3275 | 1.3275 | 1.3275 | 1.3275 | 0.2655 | 1.0000 |
PSZ-AC_8:8 | 1.3262 | 1.3262 | 1.3262 | 1.3262 | 0.2655 | 1.0000 |
PSZ-AC_9:9 | 1.3385 | 1.3385 | 1.3385 | 1.3385 | 0.2655 | 1.0000 |
PSZ-AC_10:10 | 1.5081 | 1.5081 | 1.5081 | 1.5081 | 0.2655 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.5919 | 2.5919 | 2.5919 | 0.5309 | 0.2106 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.3629 | 1.3629 | 1.3629 | 0.2655 | 0.2062 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.2960 | 1.2960 | 1.2960 | 0.2655 | 0.2048 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.2992 | 1.2992 | 1.2992 | 0.2655 | 0.2043 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.3072 | 1.3072 | 1.3072 | 0.2655 | 0.2031 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 2.4237 | 2.4237 | 2.4237 | 0.5309 | 0.2190 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.3275 | 1.3275 | 1.3275 | 0.2655 | 0.2000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.3262 | 1.3262 | 1.3262 | 0.2655 | 0.2002 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.3385 | 1.3385 | 1.3385 | 0.2655 | 0.1983 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.5081 | 1.5081 | 1.5081 | 0.2655 | 0.1760 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.5919 | 2.5919 | 2.5919 | 2.5919 | 0.5309 | 1.0000 |
PSZ-AC_2:2 | 1.3629 | 1.3629 | 1.3629 | 1.3629 | 0.2655 | 1.0000 |
PSZ-AC_3:3 | 1.2960 | 1.2960 | 1.2960 | 1.2960 | 0.2655 | 1.0000 |
PSZ-AC_4:4 | 1.2992 | 1.2992 | 1.2992 | 1.2992 | 0.2655 | 1.0000 |
PSZ-AC_5:5 | 1.3072 | 1.3072 | 1.3072 | 1.3072 | 0.2655 | 1.0000 |
PSZ-AC_6:6 | 2.4237 | 2.4237 | 2.4237 | 2.4237 | 0.5309 | 1.0000 |
PSZ-AC_7:7 | 1.3275 | 1.3275 | 1.3275 | 1.3275 | 0.2655 | 1.0000 |
PSZ-AC_8:8 | 1.3262 | 1.3262 | 1.3262 | 1.3262 | 0.2655 | 1.0000 |
PSZ-AC_9:9 | 1.3385 | 1.3385 | 1.3385 | 1.3385 | 0.2655 | 1.0000 |
PSZ-AC_10:10 | 1.5081 | 1.5081 | 1.5081 | 1.5081 | 0.2655 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:00
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Total gross floor area [m2] | 2090.32 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 3.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 3.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 879.76 | 438828.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 85.35 | 64387.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 708.74 | 43732.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 166.68 | 10625.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.72 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 304.59 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 66.08 | 15683.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.72 | 1460.16 |
Natural Gas | 0.00 | 879.76 |
Additional | 0.00 | 0.00 |
Total | 128.72 | 2339.93 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 339.06 |
Space Heating | 0.00 |
Space Cooling | 40.83 |
Fans (All) | 145.72 |
Service Water Heating | 31.61 |
Receptacle Equipment | 61.58 |
Miscellaneous (All) | 698.54 |
Subtotal | 698.54 |
Natural Gas [MJ/m2] | |
Space Heating | 420.88 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 420.88 |
Subtotal | 420.88 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 30.29 |
Space Heating | 37.60 |
Space Cooling | 3.65 |
Fans (All) | 13.02 |
Service Water Heating | 2.82 |
Receptacle Equipment | 5.50 |
Miscellaneous | 7.12 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5131. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4888. | 8760. |
TYPE2_EQUIP_SCH | 3911. | 8760. |
TYPE3_EQUIP_SCH | 3600. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2006
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.253246E+12 |
February | 0.000 | 0.143369E+12 |
March | 0.000 | 0.116110E+12 |
April | 0.000 | 0.457711E+11 |
May | 0.000 | 0.288213E+11 |
June | 0.000 | 0.125112E+10 |
July | 0.000 | 1791702.229 |
August | 0.000 | 0.145968E+09 |
September | 0.000 | 0.561600E+10 |
October | 0.000 | 0.198760E+11 |
November | 0.000 | 0.827188E+11 |
December | 0.000 | 0.182838E+12 |
Annual Sum or Average | 0.879765E+12 | |
Minimum of Months | 0.000 | 1791702.229 |
Maximum of Months | 0.000 | 0.253246E+12 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.963010E+09 | 24066.09 | 28-JAN-00:01 | -29.2 | -29.5 | 0.567836E+09 | 680.12 | 13-JAN-13:30 | 5.85 | 2.12 |
February | 0.192205E+10 | 19510.97 | 04-FEB-00:01 | -21.0 | -21.3 | 0.522259E+09 | 879.13 | 26-FEB-17:10 | 14.85 | 5.61 |
March | 0.261503E+10 | 17396.25 | 04-MAR-00:01 | -17.2 | -17.7 | 0.566259E+09 | 712.73 | 26-MAR-17:00 | 8.90 | 1.04 |
April | 0.424027E+10 | 10753.79 | 28-APR-23:12 | -4.8 | -6.3 | 0.608686E+09 | 898.99 | 16-APR-17:19 | 19.80 | 8.87 |
May | 0.708904E+10 | 13529.18 | 20-MAY-16:10 | 29.82 | 15.08 | 0.673823E+09 | 899.02 | 19-MAY-12:09 | 24.27 | 14.49 |
June | 0.126726E+11 | 16292.32 | 21-JUN-07:03 | 18.58 | 13.67 | 0.714976E+09 | 899.06 | 04-JUN-12:09 | 23.12 | 14.05 |
July | 0.181296E+11 | 37711.02 | 18-JUL-07:02 | 24.27 | 14.52 | 0.753450E+09 | 899.08 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.169391E+11 | 36394.84 | 07-AUG-07:02 | 22.77 | 12.36 | 0.739098E+09 | 899.03 | 20-AUG-17:10 | 23.22 | 14.10 |
September | 0.126745E+11 | 42465.90 | 05-SEP-07:02 | 18.98 | 12.61 | 0.703302E+09 | 899.09 | 10-SEP-12:39 | 19.23 | 13.23 |
October | 0.802585E+10 | 12442.50 | 18-OCT-15:00 | 25.00 | 11.58 | 0.678186E+09 | 898.99 | 29-OCT-17:19 | 10.20 | 4.47 |
November | 0.370962E+10 | 8623.93 | 10-NOV-01:00 | -1.6 | -3.2 | 0.581143E+09 | 898.97 | 05-NOV-17:00 | 11.60 | 5.18 |
December | 0.147035E+10 | 20957.67 | 29-DEC-00:01 | -23.6 | -23.9 | 0.571109E+09 | 680.12 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.904511E+11 | 0.768013E+10 | ||||||||
Minimum of Months | 0.963010E+09 | 8623.93 | -29.2 | -29.5 | 0.522259E+09 | 680.12 | 3.95 | 0.92 | ||
Maximum of Months | 0.181296E+11 | 42465.90 | 29.82 | 15.08 | 0.753450E+09 | 899.09 | 26.70 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.301374E+09 | 4644.46 | 11-JAN-20:42 | -2.8 | -5.0 | 0.290323E+09 | 411.99 | 01-JAN-18:00 | 2.80 | -0.1 |
February | 0.710646E+09 | 3816.88 | 28-FEB-21:00 | 2.20 | -0.1 | 0.272113E+09 | 449.50 | 26-FEB-17:10 | 14.85 | 5.61 |
March | 0.112437E+10 | 3768.66 | 14-MAR-20:00 | 2.20 | 0.55 | 0.296575E+09 | 442.00 | 26-MAR-17:00 | 8.90 | 1.04 |
April | 0.195388E+10 | 23488.84 | 25-APR-20:02 | 12.12 | 5.44 | 0.320556E+09 | 449.50 | 23-APR-16:10 | 17.70 | 9.69 |
May | 0.380382E+10 | 24749.17 | 31-MAY-20:57 | 17.20 | 7.85 | 0.344509E+09 | 449.51 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.715654E+10 | 25412.23 | 04-JUN-19:38 | 16.50 | 8.94 | 0.356380E+09 | 449.53 | 04-JUN-12:09 | 23.12 | 14.05 |
July | 0.986274E+10 | 25957.57 | 27-JUL-20:37 | 16.33 | 9.56 | 0.374444E+09 | 449.54 | 09-JUL-17:00 | 27.80 | 13.12 |
August | 0.923018E+10 | 26167.31 | 14-AUG-20:40 | 16.33 | 9.36 | 0.367710E+09 | 449.51 | 20-AUG-17:10 | 23.22 | 14.10 |
September | 0.675997E+10 | 24828.37 | 23-SEP-18:06 | 17.85 | 10.44 | 0.353850E+09 | 449.54 | 10-SEP-12:39 | 19.23 | 13.23 |
October | 0.390653E+10 | 24759.99 | 15-OCT-17:57 | 17.20 | 8.46 | 0.349852E+09 | 449.49 | 22-OCT-17:19 | 15.57 | 7.64 |
November | 0.158951E+10 | 20606.47 | 04-NOV-18:15 | 14.57 | 6.90 | 0.303790E+09 | 449.49 | 05-NOV-17:40 | 12.17 | 5.42 |
December | 0.523028E+09 | 6321.73 | 15-DEC-18:52 | -8.9 | -9.2 | 0.293783E+09 | 400.57 | 10-DEC-18:00 | 0.00 | -3.2 |
Annual Sum or Average | 0.469226E+11 | 0.392388E+10 | ||||||||
Minimum of Months | 0.301374E+09 | 3768.66 | -8.9 | -9.2 | 0.272113E+09 | 400.57 | 0.00 | -3.2 | ||
Maximum of Months | 0.986274E+10 | 26167.31 | 17.85 | 10.44 | 0.374444E+09 | 449.54 | 27.80 | 14.10 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 61134916.77 | 5241.12 | 17-JAN-18:25 | -4.7 | -5.4 | 0.169143E+09 | 340.06 | 14-JAN-13:00 | 9.40 | 4.28 |
February | 0.321932E+09 | 5493.53 | 28-FEB-08:61 | -4.5 | -4.7 | 0.156140E+09 | 390.07 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.555789E+09 | 4281.79 | 01-MAR-09:32 | -0.9 | -2.2 | 0.174523E+09 | 341.05 | 18-MAR-12:00 | 11.70 | 3.92 |
April | 0.106104E+10 | 4762.77 | 27-APR-07:01 | -1.6 | -3.1 | 0.180385E+09 | 401.20 | 08-APR-12:20 | 12.80 | 6.14 |
May | 0.200322E+10 | 6417.94 | 20-MAY-16:00 | 30.00 | 15.19 | 0.201245E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.437296E+10 | 15469.91 | 22-JUN-06:02 | 16.57 | 13.82 | 0.219515E+09 | 449.52 | 24-JUN-12:09 | 27.07 | 16.02 |
July | 0.640720E+10 | 23256.93 | 27-JUL-06:01 | 13.40 | 10.16 | 0.224122E+09 | 449.53 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.608854E+10 | 22875.89 | 07-AUG-06:02 | 19.45 | 10.89 | 0.228621E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.414971E+10 | 22285.13 | 04-SEP-07:02 | 20.02 | 12.32 | 0.209222E+09 | 449.50 | 23-SEP-12:09 | 21.28 | 11.86 |
October | 0.229280E+10 | 5736.67 | 18-OCT-14:00 | 25.00 | 11.37 | 0.198108E+09 | 449.49 | 28-OCT-12:09 | 18.12 | 9.55 |
November | 0.865208E+09 | 5065.33 | 06-NOV-08:61 | -2.4 | -3.4 | 0.169452E+09 | 440.41 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 0.158943E+09 | 7009.94 | 22-DEC-20:02 | -11.2 | -12.0 | 0.168945E+09 | 340.06 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.283385E+11 | 0.229942E+10 | ||||||||
Minimum of Months | 61134916.77 | 4281.79 | -11.2 | -12.0 | 0.156140E+09 | 340.06 | 3.95 | 0.92 | ||
Maximum of Months | 0.640720E+10 | 23256.93 | 30.00 | 15.19 | 0.228621E+09 | 449.53 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 35010614.78 | 3639.51 | 04-JAN-20:33 | 1.10 | -2.3 | 0.169143E+09 | 340.06 | 14-JAN-13:00 | 9.40 | 4.28 |
February | 0.247983E+09 | 5199.19 | 23-FEB-11:35 | -4.6 | -6.2 | 0.155683E+09 | 383.72 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.443542E+09 | 4071.82 | 30-MAR-10:33 | -0.6 | -2.0 | 0.174237E+09 | 340.06 | 11-MAR-13:09 | 11.70 | 5.12 |
April | 0.890809E+09 | 4449.59 | 27-APR-09:02 | -1.6 | -2.9 | 0.178918E+09 | 393.45 | 08-APR-12:20 | 12.80 | 6.14 |
May | 0.181413E+10 | 6278.78 | 20-MAY-16:00 | 30.00 | 15.19 | 0.200256E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.424373E+10 | 14958.36 | 22-JUN-06:02 | 16.57 | 13.82 | 0.219319E+09 | 449.52 | 24-JUN-12:09 | 27.07 | 16.02 |
July | 0.634603E+10 | 23393.48 | 27-JUL-06:01 | 13.40 | 10.16 | 0.224100E+09 | 449.53 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.601019E+10 | 23007.83 | 07-AUG-06:02 | 19.45 | 10.89 | 0.228534E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.401732E+10 | 22414.08 | 04-SEP-07:02 | 20.02 | 12.32 | 0.208687E+09 | 449.50 | 23-SEP-12:09 | 21.28 | 11.86 |
October | 0.207979E+10 | 5520.02 | 18-OCT-14:00 | 25.00 | 11.37 | 0.196457E+09 | 449.49 | 28-OCT-12:50 | 17.38 | 9.01 |
November | 0.711539E+09 | 4946.46 | 30-NOV-18:42 | -3.6 | -5.3 | 0.168288E+09 | 431.27 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 0.107416E+09 | 5278.62 | 14-DEC-20:03 | -4.9 | -6.4 | 0.168943E+09 | 340.06 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.269475E+11 | 0.229256E+10 | ||||||||
Minimum of Months | 35010614.78 | 3639.51 | -4.9 | -6.4 | 0.155683E+09 | 340.06 | 3.95 | 0.92 | ||
Maximum of Months | 0.634603E+10 | 23393.48 | 30.00 | 15.19 | 0.228534E+09 | 449.53 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 22524983.23 | 5193.20 | 03-JAN-18:42 | -4.6 | -7.0 | 0.169142E+09 | 340.06 | 14-JAN-13:09 | 10.40 | 5.00 |
February | 0.190115E+09 | 4355.43 | 16-FEB-19:12 | -1.3 | -3.7 | 0.155377E+09 | 378.11 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.354551E+09 | 4039.19 | 30-MAR-19:43 | -0.5 | -2.0 | 0.174084E+09 | 340.06 | 11-MAR-13:09 | 11.70 | 5.12 |
April | 0.748186E+09 | 3657.75 | 13-APR-07:01 | 2.32 | 0.45 | 0.177823E+09 | 386.39 | 08-APR-12:30 | 12.80 | 6.12 |
May | 0.162882E+10 | 6108.31 | 20-MAY-16:00 | 30.00 | 15.19 | 0.199392E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.405162E+10 | 12996.03 | 22-JUN-06:02 | 16.57 | 13.82 | 0.219037E+09 | 449.52 | 24-JUN-12:09 | 27.07 | 16.02 |
July | 0.616988E+10 | 21334.57 | 18-JUL-06:02 | 20.15 | 13.13 | 0.224058E+09 | 449.54 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.582902E+10 | 23080.91 | 07-AUG-06:02 | 19.45 | 10.89 | 0.228424E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.384751E+10 | 22464.22 | 04-SEP-07:02 | 20.02 | 12.32 | 0.208178E+09 | 449.50 | 09-SEP-12:09 | 25.18 | 12.44 |
October | 0.189690E+10 | 5310.15 | 18-OCT-14:00 | 25.00 | 11.37 | 0.195042E+09 | 449.49 | 28-OCT-12:00 | 17.20 | 8.87 |
November | 0.595231E+09 | 4920.43 | 20-NOV-20:33 | -3.5 | -6.3 | 0.167489E+09 | 424.23 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 75154634.13 | 5013.52 | 21-DEC-19:23 | -3.9 | -6.3 | 0.168939E+09 | 340.06 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.254095E+11 | 0.228699E+10 | ||||||||
Minimum of Months | 22524983.23 | 3657.75 | -4.6 | -7.0 | 0.155377E+09 | 340.06 | 3.95 | 0.92 | ||
Maximum of Months | 0.616988E+10 | 23080.91 | 30.00 | 15.19 | 0.228424E+09 | 449.54 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 7129539.99 | 2072.43 | 14-JAN-12:00 | 10.00 | 4.77 | 0.578270E+09 | 906.82 | 14-JAN-15:00 | 10.00 | 4.55 |
February | 0.235824E+09 | 5965.09 | 16-FEB-11:53 | 4.40 | -0.6 | 0.531926E+09 | 1033.75 | 27-FEB-15:00 | 18.90 | 7.03 |
March | 0.411938E+09 | 4543.18 | 01-MAR-14:05 | 6.97 | 2.87 | 0.596891E+09 | 907.07 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.109023E+10 | 5504.33 | 09-APR-10:43 | 5.32 | 1.42 | 0.605107E+09 | 1069.89 | 01-APR-14:00 | 18.30 | 6.98 |
May | 0.256823E+10 | 10850.27 | 20-MAY-16:00 | 30.00 | 15.19 | 0.675655E+09 | 1198.64 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.686787E+10 | 13924.53 | 23-JUN-14:10 | 31.13 | 15.20 | 0.749255E+09 | 1198.68 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.107049E+11 | 36107.09 | 17-JUL-07:02 | 23.17 | 14.92 | 0.766563E+09 | 1198.68 | 15-JUL-14:09 | 32.20 | 18.27 |
August | 0.100827E+11 | 38179.94 | 07-AUG-07:02 | 22.77 | 12.36 | 0.782767E+09 | 1198.65 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.648343E+10 | 41323.17 | 05-SEP-07:02 | 18.98 | 12.61 | 0.711989E+09 | 1198.66 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.301300E+10 | 9475.31 | 18-OCT-14:40 | 25.00 | 11.51 | 0.658855E+09 | 1198.65 | 28-OCT-14:09 | 19.08 | 9.41 |
November | 0.816390E+09 | 4642.83 | 06-NOV-12:00 | 5.70 | 1.76 | 0.566628E+09 | 1174.46 | 04-NOV-14:50 | 16.78 | 7.98 |
December | 41577495.21 | 8626.00 | 06-DEC-20:42 | -0.5 | -2.3 | 0.579250E+09 | 906.82 | 09-DEC-15:20 | 8.73 | 3.32 |
Annual Sum or Average | 0.423232E+11 | 0.780315E+10 | ||||||||
Minimum of Months | 7129539.99 | 2072.43 | -0.5 | -2.3 | 0.531926E+09 | 906.82 | 8.73 | 3.32 | ||
Maximum of Months | 0.107049E+11 | 41323.17 | 31.13 | 15.20 | 0.782767E+09 | 1198.68 | 32.20 | 18.27 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4359025.60 | 2110.58 | 13-JAN-18:55 | 6.70 | 3.16 | 0.289134E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 96381403.80 | 2155.15 | 27-FEB-18:40 | 7.93 | 3.27 | 0.265947E+09 | 516.60 | 27-FEB-15:00 | 18.90 | 7.03 |
March | 0.177479E+09 | 2794.12 | 21-MAR-10:53 | 4.40 | 0.96 | 0.298449E+09 | 453.68 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.453402E+09 | 4557.53 | 27-APR-19:53 | -2.2 | -3.5 | 0.302429E+09 | 532.77 | 01-APR-14:00 | 18.30 | 6.98 |
May | 0.119181E+10 | 5702.53 | 20-MAY-16:00 | 30.00 | 15.19 | 0.337728E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.342424E+10 | 7321.67 | 23-JUN-14:00 | 31.70 | 15.22 | 0.374623E+09 | 599.34 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.549232E+10 | 19506.07 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383292E+09 | 599.34 | 15-JUL-14:09 | 32.20 | 18.27 |
August | 0.514336E+10 | 20599.97 | 07-AUG-07:02 | 22.77 | 12.36 | 0.391432E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.323248E+10 | 22367.24 | 05-SEP-07:02 | 18.98 | 12.61 | 0.356035E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.138317E+10 | 4924.56 | 18-OCT-14:40 | 25.00 | 11.51 | 0.329549E+09 | 599.32 | 28-OCT-14:09 | 19.08 | 9.41 |
November | 0.346932E+09 | 4929.36 | 11-NOV-11:53 | -3.7 | -5.3 | 0.283445E+09 | 585.87 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 16974935.79 | 3345.31 | 07-DEC-20:43 | 2.20 | -0.3 | 0.289625E+09 | 453.41 | 09-DEC-15:20 | 8.73 | 3.32 |
Annual Sum or Average | 0.209629E+11 | 0.390169E+10 | ||||||||
Minimum of Months | 4359025.60 | 2110.58 | -3.7 | -5.3 | 0.265947E+09 | 453.41 | 8.73 | 3.32 | ||
Maximum of Months | 0.549232E+10 | 22367.24 | 31.70 | 15.22 | 0.391432E+09 | 599.34 | 32.20 | 18.27 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3312655.96 | 2024.91 | 13-JAN-18:35 | 7.07 | 3.41 | 0.289134E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 86985833.86 | 2092.22 | 27-FEB-18:30 | 8.30 | 3.49 | 0.265774E+09 | 512.70 | 27-FEB-15:00 | 18.90 | 7.03 |
March | 0.158045E+09 | 3349.25 | 21-MAR-17:03 | 2.20 | 0.74 | 0.298412E+09 | 453.41 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.409805E+09 | 3206.56 | 20-APR-18:03 | 2.80 | 2.30 | 0.301682E+09 | 531.90 | 24-APR-16:00 | 18.30 | 8.95 |
May | 0.112299E+10 | 5597.10 | 20-MAY-16:00 | 30.00 | 15.19 | 0.337004E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.331616E+10 | 7243.89 | 23-JUN-14:00 | 31.70 | 15.22 | 0.374131E+09 | 599.34 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.539267E+10 | 19442.01 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383234E+09 | 599.34 | 15-JUL-14:09 | 32.20 | 18.27 |
August | 0.504689E+10 | 20548.27 | 07-AUG-07:02 | 22.77 | 12.36 | 0.391375E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.315580E+10 | 22306.16 | 05-SEP-07:02 | 18.98 | 12.61 | 0.355555E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.131999E+10 | 4810.04 | 18-OCT-14:40 | 25.00 | 11.51 | 0.328507E+09 | 599.32 | 28-OCT-14:30 | 19.45 | 9.56 |
November | 0.317226E+09 | 2157.37 | 06-NOV-12:00 | 5.70 | 1.76 | 0.283111E+09 | 582.23 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 13358065.18 | 887.89 | 07-DEC-12:00 | 7.80 | 3.02 | 0.289625E+09 | 453.41 | 09-DEC-15:20 | 8.73 | 3.32 |
Annual Sum or Average | 0.203432E+11 | 0.389754E+10 | ||||||||
Minimum of Months | 3312655.96 | 887.89 | 2.20 | 0.74 | 0.265774E+09 | 453.41 | 8.73 | 3.32 | ||
Maximum of Months | 0.539267E+10 | 22306.16 | 31.70 | 15.22 | 0.391375E+09 | 599.34 | 32.20 | 18.27 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1688978.87 | 744.66 | 14-JAN-12:00 | 10.00 | 4.77 | 0.289135E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 57201565.05 | 1863.34 | 27-FEB-18:10 | 9.03 | 3.92 | 0.265302E+09 | 501.50 | 27-FEB-15:00 | 18.90 | 7.03 |
March | 90326771.51 | 3556.71 | 24-MAR-19:03 | 1.23 | -2.2 | 0.298299E+09 | 453.41 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.286725E+09 | 3121.16 | 18-APR-18:33 | 3.10 | 2.59 | 0.299486E+09 | 531.90 | 06-APR-16:10 | 22.02 | 10.90 |
May | 0.926290E+09 | 5331.35 | 20-MAY-16:00 | 30.00 | 15.19 | 0.334988E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.303109E+10 | 7096.39 | 23-JUN-14:00 | 31.70 | 15.22 | 0.372514E+09 | 599.34 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.516468E+10 | 19421.39 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383012E+09 | 599.35 | 15-JUL-14:09 | 32.20 | 18.27 |
August | 0.482249E+10 | 20582.53 | 07-AUG-07:02 | 22.77 | 12.36 | 0.391179E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.296191E+10 | 22338.50 | 05-SEP-07:02 | 18.98 | 12.61 | 0.354215E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.114206E+10 | 4524.44 | 18-OCT-14:50 | 25.00 | 11.55 | 0.325912E+09 | 599.32 | 28-OCT-14:50 | 19.82 | 9.71 |
November | 0.238530E+09 | 3382.02 | 10-NOV-10:33 | 1.93 | -1.1 | 0.282277E+09 | 572.97 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 7643355.22 | 3330.09 | 07-DEC-20:03 | 2.20 | -0.3 | 0.289624E+09 | 453.41 | 09-DEC-15:20 | 8.73 | 3.32 |
Annual Sum or Average | 0.187306E+11 | 0.388594E+10 | ||||||||
Minimum of Months | 1688978.87 | 744.66 | 1.23 | -2.2 | 0.265302E+09 | 453.41 | 8.73 | 3.32 | ||
Maximum of Months | 0.516468E+10 | 22338.50 | 31.70 | 15.22 | 0.391179E+09 | 599.35 | 32.20 | 18.27 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.1 | 0.289135E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 5680422.82 | 607.08 | 27-FEB-18:10 | 9.03 | 3.92 | 0.264378E+09 | 475.77 | 27-FEB-15:00 | 18.90 | 7.03 |
March | 3462384.79 | 2453.76 | 01-MAR-18:05 | 4.53 | 1.65 | 0.298193E+09 | 453.41 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 60175518.44 | 1129.89 | 08-APR-10:30 | 12.25 | 5.93 | 0.295285E+09 | 531.91 | 06-APR-16:30 | 21.65 | 10.71 |
May | 0.514992E+09 | 4919.03 | 20-MAY-16:00 | 30.00 | 15.19 | 0.330581E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.254357E+10 | 7082.79 | 23-JUN-13:50 | 31.60 | 15.21 | 0.368197E+09 | 599.34 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.497422E+10 | 14997.48 | 17-JUL-07:02 | 23.17 | 14.92 | 0.382159E+09 | 599.35 | 15-JUL-14:09 | 32.20 | 18.27 |
August | 0.454281E+10 | 12057.06 | 07-AUG-07:02 | 22.77 | 12.36 | 0.390538E+09 | 599.33 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.258813E+10 | 18532.40 | 04-SEP-08:62 | 25.78 | 14.38 | 0.351472E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.708436E+09 | 4152.73 | 18-OCT-14:40 | 25.00 | 11.51 | 0.321291E+09 | 599.33 | 28-OCT-14:00 | 20.00 | 9.78 |
November | 67732674.57 | 1143.15 | 03-NOV-11:00 | 11.10 | 6.70 | 0.280911E+09 | 552.54 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 0.00 | 0.00 | 01-DEC-00:03 | -2.1 | -4.1 | 0.289625E+09 | 453.41 | 09-DEC-15:20 | 8.73 | 3.32 |
Annual Sum or Average | 0.160092E+11 | 0.386176E+10 | ||||||||
Minimum of Months | 0.00 | 0.00 | -2.1 | -4.1 | 0.264378E+09 | 453.41 | 8.73 | 3.32 | ||
Maximum of Months | 0.497422E+10 | 18532.40 | 31.60 | 15.21 | 0.390538E+09 | 599.35 | 32.20 | 18.27 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.144654E+11 | 78996.80 | 29-JAN-08:61 | -29.8 |
February | 0.714982E+10 | 78835.69 | 10-FEB-08:61 | -18.8 |
March | 0.518282E+10 | 78687.71 | 06-MAR-08:61 | -16.9 |
April | 0.176088E+10 | 78565.09 | 22-APR-07:01 | 2.85 |
May | 0.110182E+10 | 78530.36 | 01-MAY-07:01 | 0.78 |
June | 0.126955E+09 | 24446.87 | 17-JUN-07:01 | 8.77 |
July | 47585411.43 | 4328.94 | 18-JUL-07:04 | 24.27 |
August | 65786035.54 | 4224.58 | 07-AUG-07:04 | 22.77 |
September | 0.184807E+09 | 78464.87 | 20-SEP-07:01 | 4.78 |
October | 0.507952E+09 | 78549.75 | 10-OCT-07:01 | -5.7 |
November | 0.304090E+10 | 78619.16 | 21-NOV-08:61 | -8.0 |
December | 0.873343E+10 | 78936.47 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.423682E+11 | |||
Minimum of Months | 47585411.43 | 4224.58 | -29.8 | |
Maximum of Months | 0.144654E+11 | 78996.80 | 24.27 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.608641E+10 | 40759.11 | 27-JAN-08:61 | -27.2 |
February | 0.288489E+10 | 40687.11 | 05-FEB-08:61 | -20.1 |
March | 0.188034E+10 | 40669.64 | 04-MAR-08:61 | -19.9 |
April | 0.536254E+09 | 40596.97 | 29-APR-07:01 | -4.5 |
May | 0.360217E+09 | 40585.00 | 01-MAY-07:01 | 0.78 |
June | 41063063.95 | 2115.55 | 21-JUN-07:05 | 18.58 |
July | 21611538.94 | 2442.94 | 26-JUL-07:05 | 23.68 |
August | 26127586.88 | 2420.42 | 07-AUG-07:04 | 22.77 |
September | 76155252.45 | 17760.86 | 20-SEP-07:01 | 4.78 |
October | 0.188248E+09 | 39021.14 | 10-OCT-07:01 | -5.7 |
November | 0.122078E+10 | 40637.05 | 26-NOV-08:61 | -16.6 |
December | 0.367167E+10 | 40688.94 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.169938E+11 | |||
Minimum of Months | 21611538.94 | 2115.55 | -27.6 | |
Maximum of Months | 0.608641E+10 | 40759.11 | 23.68 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.733828E+10 | 39495.41 | 08-JAN-08:61 | -27.2 |
February | 0.370369E+10 | 39477.33 | 05-FEB-08:61 | -20.1 |
March | 0.263033E+10 | 39388.64 | 05-MAR-08:61 | -18.1 |
April | 0.872235E+09 | 39309.90 | 29-APR-06:01 | -6.8 |
May | 0.584294E+09 | 39302.82 | 01-MAY-06:01 | 0.10 |
June | 77278805.63 | 2043.05 | 22-JUN-06:04 | 16.57 |
July | 0.108687E+09 | 3542.58 | 17-JUL-19:02 | 33.48 |
August | 88339045.51 | 4065.74 | 06-AUG-16:01 | 35.50 |
September | 0.122973E+09 | 17484.81 | 20-SEP-06:02 | 3.48 |
October | 0.311514E+09 | 38913.96 | 10-OCT-06:01 | -6.1 |
November | 0.179885E+10 | 39379.50 | 26-NOV-08:61 | -16.6 |
December | 0.477119E+10 | 39453.48 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.224077E+11 | |||
Minimum of Months | 77278805.63 | 2043.05 | -27.6 | |
Maximum of Months | 0.733828E+10 | 39495.41 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.776146E+10 | 39561.56 | 29-JAN-08:61 | -29.8 |
February | 0.398060E+10 | 39576.76 | 05-FEB-08:61 | -20.1 |
March | 0.290686E+10 | 39497.96 | 05-MAR-08:61 | -18.1 |
April | 0.102072E+10 | 39373.32 | 29-APR-06:01 | -6.8 |
May | 0.680316E+09 | 39367.64 | 01-MAY-06:01 | 0.10 |
June | 84066003.79 | 2025.12 | 22-JUN-06:04 | 16.57 |
July | 0.110123E+09 | 3546.00 | 17-JUL-19:02 | 33.48 |
August | 91324431.43 | 4069.31 | 06-AUG-16:01 | 35.50 |
September | 0.144451E+09 | 21552.02 | 20-SEP-06:02 | 3.48 |
October | 0.382803E+09 | 38977.53 | 10-OCT-06:01 | -6.1 |
November | 0.200903E+10 | 39443.44 | 26-NOV-08:61 | -16.6 |
December | 0.512353E+10 | 39468.67 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.242953E+11 | |||
Minimum of Months | 84066003.79 | 2025.12 | -29.8 | |
Maximum of Months | 0.776146E+10 | 39576.76 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.819135E+10 | 39722.83 | 29-JAN-08:61 | -29.8 |
February | 0.427778E+10 | 39699.39 | 05-FEB-08:61 | -20.1 |
March | 0.319234E+10 | 39604.85 | 05-MAR-08:61 | -18.1 |
April | 0.117492E+10 | 39526.04 | 29-APR-06:01 | -6.8 |
May | 0.780364E+09 | 39520.48 | 01-MAY-06:01 | 0.10 |
June | 94775646.19 | 2945.09 | 17-JUN-06:05 | 6.05 |
July | 0.112997E+09 | 3555.16 | 17-JUL-19:02 | 33.48 |
August | 95777571.26 | 4078.48 | 06-AUG-16:01 | 35.50 |
September | 0.165158E+09 | 24364.09 | 20-SEP-06:02 | 3.48 |
October | 0.443886E+09 | 39127.10 | 10-OCT-06:01 | -6.1 |
November | 0.221517E+10 | 39596.50 | 26-NOV-08:61 | -16.6 |
December | 0.549056E+10 | 39622.70 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.262351E+11 | |||
Minimum of Months | 94775646.19 | 2945.09 | -29.8 | |
Maximum of Months | 0.819135E+10 | 39722.83 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.157060E+11 | 75711.68 | 28-JAN-08:61 | -25.1 |
February | 0.821941E+10 | 75609.16 | 05-FEB-09:01 | -20.4 |
March | 0.612177E+10 | 75551.32 | 06-MAR-08:61 | -16.9 |
April | 0.232789E+10 | 75366.68 | 28-APR-07:01 | -3.2 |
May | 0.151095E+10 | 75347.98 | 08-MAY-07:01 | -2.1 |
June | 0.164129E+09 | 33130.96 | 17-JUN-07:01 | 8.77 |
July | 0.128833E+09 | 6575.64 | 16-JUL-16:01 | 32.88 |
August | 0.129872E+09 | 8028.72 | 06-AUG-16:01 | 35.50 |
September | 0.346768E+09 | 75334.94 | 19-SEP-07:01 | 2.48 |
October | 0.898199E+09 | 75388.22 | 10-OCT-07:01 | -5.7 |
November | 0.432245E+10 | 75432.53 | 27-NOV-08:61 | -12.7 |
December | 0.105781E+11 | 75831.97 | 31-DEC-09:01 | -26.2 |
Annual Sum or Average | 0.504544E+11 | |||
Minimum of Months | 0.128833E+09 | 6575.64 | -26.2 | |
Maximum of Months | 0.157060E+11 | 75831.97 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.871532E+10 | 40183.96 | 29-JAN-09:01 | -28.4 |
February | 0.465355E+10 | 40084.97 | 10-FEB-08:61 | -18.8 |
March | 0.357145E+10 | 40023.30 | 05-MAR-09:01 | -16.9 |
April | 0.140893E+10 | 39940.86 | 29-APR-07:01 | -4.5 |
May | 0.925656E+09 | 39932.80 | 08-MAY-07:01 | -2.1 |
June | 0.101339E+09 | 17580.99 | 17-JUN-07:01 | 8.77 |
July | 72311833.34 | 3388.77 | 16-JUL-16:01 | 32.88 |
August | 74694281.44 | 4114.28 | 06-AUG-16:01 | 35.50 |
September | 0.215138E+09 | 39922.87 | 19-SEP-07:01 | 2.48 |
October | 0.555827E+09 | 39955.13 | 10-OCT-07:01 | -5.7 |
November | 0.251646E+10 | 39973.95 | 21-NOV-08:61 | -8.0 |
December | 0.597145E+10 | 40112.65 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.287821E+11 | |||
Minimum of Months | 72311833.34 | 3388.77 | -28.4 | |
Maximum of Months | 0.871532E+10 | 40183.96 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.878487E+10 | 40162.26 | 29-JAN-09:01 | -28.4 |
February | 0.472524E+10 | 40134.64 | 05-FEB-09:01 | -20.4 |
March | 0.366192E+10 | 40002.46 | 05-MAR-09:01 | -16.9 |
April | 0.148066E+10 | 39917.64 | 29-APR-07:01 | -4.5 |
May | 0.971608E+09 | 39909.60 | 08-MAY-07:01 | -2.1 |
June | 0.108700E+09 | 20413.61 | 17-JUN-07:01 | 8.77 |
July | 74437667.52 | 3392.12 | 16-JUL-16:01 | 32.88 |
August | 79181190.13 | 4117.32 | 06-AUG-16:01 | 35.50 |
September | 0.227869E+09 | 39899.49 | 19-SEP-07:01 | 2.48 |
October | 0.582007E+09 | 39931.84 | 10-OCT-07:01 | -5.7 |
November | 0.258005E+10 | 39957.88 | 27-NOV-08:61 | -12.7 |
December | 0.605583E+10 | 40091.11 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.293324E+11 | |||
Minimum of Months | 74437667.52 | 3392.12 | -28.4 | |
Maximum of Months | 0.878487E+10 | 40162.26 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.926654E+10 | 40402.42 | 27-JAN-08:61 | -27.2 |
February | 0.510987E+10 | 40305.30 | 05-FEB-09:01 | -20.4 |
March | 0.409971E+10 | 40253.48 | 05-MAR-09:01 | -16.9 |
April | 0.179608E+10 | 40156.81 | 28-APR-07:01 | -3.2 |
May | 0.116241E+10 | 40142.96 | 01-MAY-07:01 | 0.78 |
June | 0.137994E+09 | 31379.82 | 17-JUN-07:01 | 8.77 |
July | 84100206.43 | 3405.80 | 16-JUL-16:01 | 32.88 |
August | 95974723.74 | 8277.58 | 18-AUG-07:02 | 10.37 |
September | 0.275842E+09 | 40134.72 | 19-SEP-07:01 | 2.48 |
October | 0.687780E+09 | 40165.76 | 10-OCT-07:01 | -5.7 |
November | 0.286597E+10 | 40232.32 | 27-NOV-08:61 | -12.7 |
December | 0.649329E+10 | 40346.66 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.320755E+11 | |||
Minimum of Months | 84100206.43 | 3405.80 | -27.9 | |
Maximum of Months | 0.926654E+10 | 40402.42 | 32.88 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.137612E+11 | 43988.20 | 11-JAN-01:11 | -31.3 |
February | 0.805054E+10 | 43571.34 | 04-FEB-08:61 | -20.0 |
March | 0.696147E+10 | 43544.21 | 06-MAR-08:61 | -16.9 |
April | 0.344839E+10 | 43351.89 | 15-APR-07:01 | 1.28 |
May | 0.216157E+10 | 43403.15 | 08-MAY-07:01 | -2.1 |
June | 0.264543E+09 | 42708.21 | 17-JUN-07:01 | 8.77 |
July | 0.121500E+09 | 3440.08 | 16-JUL-16:01 | 32.88 |
August | 0.148596E+09 | 37293.21 | 18-AUG-07:02 | 10.37 |
September | 0.501937E+09 | 43252.03 | 19-SEP-07:01 | 2.48 |
October | 0.121497E+10 | 43328.01 | 10-OCT-07:01 | -5.7 |
November | 0.452348E+10 | 43497.47 | 27-NOV-08:61 | -12.7 |
December | 0.965323E+10 | 43668.83 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.508114E+11 | |||
Minimum of Months | 0.121500E+09 | 3440.08 | -31.3 | |
Maximum of Months | 0.137612E+11 | 43988.20 | 32.88 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.157219E+11 | 9537.57 | 01-JAN-10:09 | 0.223514E+10 | 1348.26 | 01-JAN-10:09 |
February | 0.142256E+11 | 9537.57 | 01-FEB-10:09 | 0.202238E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.157545E+11 | 9537.57 | 01-MAR-10:09 | 0.223972E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.152557E+11 | 9537.57 | 01-APR-09:09 | 0.216880E+10 | 1348.26 | 01-APR-09:09 |
May | 0.157219E+11 | 9537.57 | 01-MAY-09:09 | 0.223514E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.152557E+11 | 9537.57 | 01-JUN-09:09 | 0.216880E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.157545E+11 | 9537.57 | 01-JUL-09:09 | 0.223972E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.157219E+11 | 9537.57 | 01-AUG-09:09 | 0.223514E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.152882E+11 | 9537.57 | 01-SEP-09:09 | 0.217339E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.157219E+11 | 9537.57 | 01-OCT-09:09 | 0.223514E+10 | 1348.26 | 01-OCT-09:09 |
November | 0.151906E+11 | 9537.57 | 01-NOV-09:09 | 0.215964E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.157870E+11 | 9537.57 | 01-DEC-10:09 | 0.224431E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.185400E+12 | 0.263573E+11 | ||||
Minimum of Months | 0.142256E+11 | 9537.57 | 0.202238E+10 | 1348.26 | ||
Maximum of Months | 0.157870E+11 | 9537.57 | 0.224431E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.786097E+10 | 4768.79 | 01-JAN-10:09 | 0.111757E+10 | 674.13 | 01-JAN-10:09 |
February | 0.711282E+10 | 4768.79 | 01-FEB-10:09 | 0.101119E+10 | 674.13 | 01-FEB-10:09 |
March | 0.787723E+10 | 4768.79 | 01-MAR-10:09 | 0.111986E+10 | 674.13 | 01-MAR-10:09 |
April | 0.762785E+10 | 4768.79 | 01-APR-09:09 | 0.108440E+10 | 674.13 | 01-APR-09:09 |
May | 0.786097E+10 | 4768.79 | 01-MAY-09:09 | 0.111757E+10 | 674.13 | 01-MAY-09:09 |
June | 0.762785E+10 | 4768.79 | 01-JUN-09:09 | 0.108440E+10 | 674.13 | 01-JUN-09:09 |
July | 0.787723E+10 | 4768.79 | 01-JUL-09:09 | 0.111986E+10 | 674.13 | 01-JUL-09:09 |
August | 0.786097E+10 | 4768.79 | 01-AUG-09:09 | 0.111757E+10 | 674.13 | 01-AUG-09:09 |
September | 0.764411E+10 | 4768.79 | 01-SEP-09:09 | 0.108669E+10 | 674.13 | 01-SEP-09:09 |
October | 0.786097E+10 | 4768.79 | 01-OCT-09:09 | 0.111757E+10 | 674.13 | 01-OCT-09:09 |
November | 0.759532E+10 | 4768.79 | 01-NOV-09:09 | 0.107982E+10 | 674.13 | 01-NOV-09:09 |
December | 0.789349E+10 | 4768.79 | 01-DEC-10:09 | 0.112215E+10 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.926998E+11 | 0.131787E+11 | ||||
Minimum of Months | 0.711282E+10 | 4768.79 | 0.101119E+10 | 674.13 | ||
Maximum of Months | 0.789349E+10 | 4768.79 | 0.112215E+10 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.486999E+10 | 3744.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.441023E+10 | 3744.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.497215E+10 | 3744.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.472525E+10 | 3744.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.492107E+10 | 3744.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.480187E+10 | 3744.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.484444E+10 | 3744.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.497215E+10 | 3744.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.472525E+10 | 3744.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.486999E+10 | 3744.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.472525E+10 | 3744.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.484444E+10 | 3744.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.576821E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.441023E+10 | 3744.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.497215E+10 | 3744.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.486999E+10 | 3744.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.441023E+10 | 3744.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.497215E+10 | 3744.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.472525E+10 | 3744.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.492107E+10 | 3744.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.480187E+10 | 3744.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.484444E+10 | 3744.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.497215E+10 | 3744.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.472525E+10 | 3744.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.486999E+10 | 3744.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.472525E+10 | 3744.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.484444E+10 | 3744.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.576821E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.441023E+10 | 3744.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.497215E+10 | 3744.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.486999E+10 | 3744.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.441023E+10 | 3744.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.497215E+10 | 3744.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.472525E+10 | 3744.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.492107E+10 | 3744.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.480187E+10 | 3744.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.484444E+10 | 3744.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.497215E+10 | 3744.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.472525E+10 | 3744.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.486999E+10 | 3744.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.472525E+10 | 3744.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.484444E+10 | 3744.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.576821E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.441023E+10 | 3744.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.497215E+10 | 3744.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.724555E+10 | 6064.13 | 01-JAN-11:09 | 0.162546E+10 | 1348.26 | 01-JAN-11:09 |
February | 0.656305E+10 | 6064.13 | 01-FEB-10:09 | 0.147229E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.741101E+10 | 6064.13 | 01-MAR-10:09 | 0.166213E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.703184E+10 | 6064.13 | 01-APR-09:09 | 0.157746E+10 | 1348.26 | 01-APR-09:09 |
May | 0.732828E+10 | 6064.13 | 01-MAY-09:09 | 0.164379E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.715593E+10 | 6064.13 | 01-JUN-09:09 | 0.160496E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.720419E+10 | 6064.13 | 01-JUL-09:09 | 0.161629E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.741101E+10 | 6064.13 | 01-AUG-09:09 | 0.166213E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.703184E+10 | 6064.13 | 01-SEP-09:09 | 0.157746E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.724555E+10 | 6064.13 | 01-OCT-10:09 | 0.162546E+10 | 1348.26 | 01-OCT-10:09 |
November | 0.703184E+10 | 6064.13 | 01-NOV-09:09 | 0.157746E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.720419E+10 | 6064.13 | 01-DEC-10:09 | 0.161629E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.858643E+11 | 0.192612E+11 | ||||
Minimum of Months | 0.656305E+10 | 6064.13 | 0.147229E+10 | 1348.26 | ||
Maximum of Months | 0.741101E+10 | 6064.13 | 0.166213E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.157219E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136920E+11 |
February | 0.163016E+10 | 0.142256E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.916551E+10 |
March | 0.178954E+10 | 0.157545E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.841902E+10 |
April | 0.174484E+10 | 0.152557E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539394E+10 |
May | 0.179537E+10 | 0.157219E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65345973.46 | 0.472875E+10 |
June | 0.173447E+10 | 0.152557E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407431E+09 | 0.217830E+10 |
July | 0.181028E+10 | 0.157545E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110645E+10 | 0.106450E+10 |
August | 0.178501E+10 | 0.157219E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.846572E+09 | 0.151767E+10 |
September | 0.174937E+10 | 0.152882E+11 | 0.217339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388164E+09 | 0.315225E+10 |
October | 0.180574E+10 | 0.157219E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4588992.64 | 0.523657E+10 |
November | 0.174613E+10 | 0.151906E+11 | 0.215964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.780371E+10 |
December | 0.181481E+10 | 0.157870E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109591E+11 |
Annual Sum or Average | 0.212115E+11 | 0.185400E+12 | 0.263573E+11 | 0.281855E+10 | 0.733114E+11 | ||||
Minimum of Months | 0.163016E+10 | 0.142256E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106450E+10 |
Maximum of Months | 0.181481E+10 | 0.157870E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110645E+10 | 0.136920E+11 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.786097E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.677270E+10 |
February | 0.815075E+09 | 0.711282E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.448897E+10 |
March | 0.894769E+09 | 0.787723E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.413213E+10 |
April | 0.872416E+09 | 0.762785E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265772E+10 |
May | 0.897684E+09 | 0.786097E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35693401.54 | 0.223496E+10 |
June | 0.867232E+09 | 0.762785E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224421E+09 | 0.958577E+09 |
July | 0.905135E+09 | 0.787723E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609988E+09 | 0.420038E+09 |
August | 0.892501E+09 | 0.786097E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.465428E+09 | 0.646932E+09 |
September | 0.874683E+09 | 0.764411E+10 | 0.108669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213440E+09 | 0.142390E+10 |
October | 0.902868E+09 | 0.786097E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2513664.21 | 0.249916E+10 |
November | 0.873064E+09 | 0.759532E+10 | 0.107982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.378133E+10 |
December | 0.907403E+09 | 0.789349E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.542882E+10 |
Annual Sum or Average | 0.106057E+11 | 0.926998E+11 | 0.131787E+11 | 0.155148E+10 | 0.354452E+11 | ||||
Minimum of Months | 0.815075E+09 | 0.711282E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420038E+09 |
Maximum of Months | 0.907403E+09 | 0.789349E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609988E+09 | 0.677270E+10 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.693611E+10 |
February | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459649E+10 |
March | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423025E+10 |
April | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268756E+10 |
May | 0.544247E+09 | 0.492107E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35388361.06 | 0.227910E+10 |
June | 0.532585E+09 | 0.480187E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221844E+09 | 0.101384E+10 |
July | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593490E+09 | 0.473274E+09 |
August | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.458683E+09 | 0.690182E+09 |
September | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202045E+09 | 0.146996E+10 |
October | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513621.43 | 0.252259E+10 |
November | 0.518979E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.383755E+10 |
December | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557413E+10 |
Annual Sum or Average | 0.638324E+10 | 0.576821E+11 | 0.104672E+11 | 0.151396E+10 | 0.363110E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.473274E+09 |
Maximum of Months | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593490E+09 | 0.693611E+10 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.692180E+10 |
February | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.457562E+10 |
March | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.421623E+10 |
April | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266077E+10 |
May | 0.544247E+09 | 0.492107E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35390094.76 | 0.225983E+10 |
June | 0.532585E+09 | 0.480187E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221847E+09 | 0.100919E+10 |
July | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593469E+09 | 0.472510E+09 |
August | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.458617E+09 | 0.688050E+09 |
September | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201974E+09 | 0.145919E+10 |
October | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513621.64 | 0.249383E+10 |
November | 0.518979E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381012E+10 |
December | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.555852E+10 |
Annual Sum or Average | 0.638324E+10 | 0.576821E+11 | 0.104672E+11 | 0.151381E+10 | 0.361256E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472510E+09 |
Maximum of Months | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593469E+09 | 0.692180E+10 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.691399E+10 |
February | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456370E+10 |
March | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420850E+10 |
April | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264239E+10 |
May | 0.544247E+09 | 0.492107E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35392370.39 | 0.224419E+10 |
June | 0.532585E+09 | 0.480187E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221850E+09 | 0.100265E+10 |
July | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593683E+09 | 0.469012E+09 |
August | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.458692E+09 | 0.683990E+09 |
September | 0.524810E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202061E+09 | 0.144926E+10 |
October | 0.537120E+09 | 0.486999E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513621.51 | 0.247180E+10 |
November | 0.518979E+09 | 0.472525E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379294E+10 |
December | 0.536472E+09 | 0.484444E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554966E+10 |
Annual Sum or Average | 0.638324E+10 | 0.576821E+11 | 0.104672E+11 | 0.151419E+10 | 0.359921E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.441023E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.469012E+09 |
Maximum of Months | 0.551374E+09 | 0.497215E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593683E+09 | 0.691399E+10 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124895E+11 |
February | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.826018E+10 |
March | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.762450E+10 |
April | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.476511E+10 |
May | 0.186509E+10 | 0.732828E+10 | 0.164379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62355177.51 | 0.408245E+10 |
June | 0.182945E+10 | 0.715593E+10 | 0.160496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.390509E+09 | 0.185482E+10 |
July | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104651E+10 | 0.889318E+09 |
August | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.808334E+09 | 0.128262E+10 |
September | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355760E+09 | 0.267278E+10 |
October | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4425530.34 | 0.448122E+10 |
November | 0.176881E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687409E+10 |
December | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100203E+11 |
Annual Sum or Average | 0.218821E+11 | 0.858643E+11 | 0.192612E+11 | 0.266789E+10 | 0.652969E+11 | ||||
Minimum of Months | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.889318E+09 |
Maximum of Months | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104651E+10 | 0.124895E+11 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.695332E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.458257E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423108E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263545E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35401803.71 | 0.224317E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.222016E+09 | 0.100535E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595212E+09 | 0.471082E+09 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459466E+09 | 0.691397E+09 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202342E+09 | 0.145638E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513848.56 | 0.246775E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380465E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557683E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.151695E+10 | 0.361190E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.471082E+09 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595212E+09 | 0.695332E+10 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.695148E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.457894E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.422833E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262766E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35403365.60 | 0.223508E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.222025E+09 | 0.100006E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595359E+09 | 0.469054E+09 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459518E+09 | 0.689553E+09 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202407E+09 | 0.145109E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513845.89 | 0.245821E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379961E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557448E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.151723E+10 | 0.360636E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.469054E+09 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595359E+09 | 0.695148E+10 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.694101E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456295E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.421543E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260137E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35407514.35 | 0.220871E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.222080E+09 | 0.982073E+09 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595695E+09 | 0.462226E+09 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459607E+09 | 0.683290E+09 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202502E+09 | 0.143477E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2513835.57 | 0.243145E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.378161E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.556225E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.151781E+10 | 0.358671E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462226E+09 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595695E+09 | 0.694101E+10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877933E+10 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.585510E+10 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538883E+10 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330999E+10 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 37889139.43 | 0.292158E+10 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235115E+09 | 0.138998E+10 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630450E+09 | 0.751477E+09 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.487928E+09 | 0.102703E+10 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214378E+09 | 0.203202E+10 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2677439.53 | 0.322008E+10 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491529E+10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.700593E+10 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.160844E+10 | 0.465966E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.751477E+09 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630450E+09 | 0.877933E+10 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 9537.57 | 01-JAN-10:09 | 1348.26 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 24880.94 | 10-JAN-18:00 |
February | 2159.72 | 03-FEB-13:09 | 9537.57 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 20115.00 | 09-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 9537.57 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 19196.45 | 04-MAR-14:00 |
April | 2159.72 | 01-APR-12:09 | 9537.57 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 11638.40 | 27-APR-11:10 |
May | 2159.72 | 05-MAY-12:09 | 9537.57 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2610.67 | 20-MAY-16:00 | 10718.02 | 22-MAY-16:00 |
June | 2159.72 | 02-JUN-12:09 | 9537.57 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3676.50 | 29-JUN-15:00 | 7095.85 | 16-JUN-11:10 |
July | 2159.72 | 01-JUL-12:09 | 9537.57 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5515.87 | 17-JUL-16:00 | 4344.51 | 05-JUL-11:10 |
August | 2159.72 | 04-AUG-12:09 | 9537.57 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4889.85 | 05-AUG-16:00 | 6843.50 | 17-AUG-11:05 |
September | 2159.72 | 01-SEP-12:09 | 9537.57 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4506.96 | 02-SEP-15:00 | 8243.64 | 12-SEP-11:10 |
October | 2159.72 | 01-OCT-12:09 | 9537.57 | 01-OCT-09:09 | 1348.26 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 488.51 | 18-OCT-14:00 | 10018.21 | 10-OCT-11:10 |
November | 2159.72 | 03-NOV-12:09 | 9537.57 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 17574.44 | 26-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 9537.57 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 21491.17 | 28-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 9537.57 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4344.51 | |||||
Maximum of Months | 2159.72 | 9537.57 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 5515.87 | 24880.94 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 4768.79 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.94 | 10-JAN-18:00 |
February | 1079.86 | 03-FEB-13:09 | 4768.79 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.22 | 09-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 4768.79 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.73 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 4768.79 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6367.02 | 27-APR-11:10 |
May | 1079.86 | 05-MAY-12:09 | 4768.79 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.55 | 20-MAY-16:00 | 5735.19 | 22-MAY-16:00 |
June | 1079.86 | 02-JUN-12:09 | 4768.79 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.54 | 29-JUN-15:00 | 4024.67 | 16-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 4768.79 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.64 | 17-JUL-16:00 | 2457.60 | 05-JUL-11:10 |
August | 1079.86 | 04-AUG-12:09 | 4768.79 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.18 | 05-AUG-16:00 | 3808.11 | 17-AUG-11:05 |
September | 1079.86 | 01-SEP-12:09 | 4768.79 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.81 | 02-SEP-15:00 | 4494.56 | 12-SEP-11:10 |
October | 1079.86 | 01-OCT-12:09 | 4768.79 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 18-OCT-14:00 | 5531.05 | 10-OCT-11:10 |
November | 1079.86 | 03-NOV-12:09 | 4768.79 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.21 | 26-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 4768.79 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2457.60 | |||||
Maximum of Months | 1079.86 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.64 | 13931.94 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3744.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3744.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.20 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3744.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.72 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3744.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6367.00 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3744.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 20-MAY-16:00 | 5735.16 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3744.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.53 | 29-JUN-15:00 | 4006.92 | 16-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3744.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 17-JUL-16:00 | 2430.27 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3744.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.17 | 05-AUG-16:00 | 3717.63 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3744.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.80 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3744.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 18-OCT-14:00 | 5531.05 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3744.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3744.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2430.27 | |||||
Maximum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3744.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3744.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.20 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3744.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.72 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3744.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6367.00 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3744.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 20-MAY-16:00 | 5735.16 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3744.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.53 | 29-JUN-15:00 | 4006.92 | 16-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3744.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 17-JUL-16:00 | 2422.17 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3744.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.17 | 05-AUG-16:00 | 3699.28 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3744.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.80 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3744.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 18-OCT-14:00 | 5531.05 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3744.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3744.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2422.17 | |||||
Maximum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3744.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3744.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.20 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3744.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.72 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3744.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6367.01 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3744.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 20-MAY-16:00 | 5735.16 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3744.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.53 | 29-JUN-15:00 | 4006.92 | 16-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3744.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 17-JUL-16:00 | 2412.44 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3744.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.17 | 05-AUG-16:00 | 3670.26 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3744.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.80 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3744.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 18-OCT-14:00 | 5531.05 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3744.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3744.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2412.44 | |||||
Maximum of Months | 1079.86 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.63 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 6064.13 | 01-JAN-11:09 | 1348.26 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 24446.51 | 10-JAN-18:00 |
February | 2879.63 | 04-FEB-15:09 | 6064.13 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 19717.25 | 09-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 6064.13 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 18999.97 | 04-MAR-18:00 |
April | 2879.63 | 01-APR-14:09 | 6064.13 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 11210.76 | 27-APR-11:10 |
May | 2879.63 | 06-MAY-14:09 | 6064.13 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2528.79 | 20-MAY-16:00 | 10132.00 | 22-MAY-16:00 |
June | 2879.63 | 03-JUN-14:09 | 6064.13 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3505.89 | 29-JUN-15:00 | 7022.33 | 16-JUN-11:10 |
July | 2879.63 | 01-JUL-14:09 | 6064.13 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5394.27 | 17-JUL-16:00 | 4186.65 | 05-JUL-11:10 |
August | 2879.63 | 05-AUG-14:09 | 6064.13 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4768.83 | 05-AUG-16:00 | 6320.09 | 17-AUG-11:05 |
September | 2879.63 | 02-SEP-14:09 | 6064.13 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4346.23 | 02-SEP-15:00 | 7897.22 | 12-SEP-11:10 |
October | 2879.63 | 07-OCT-14:09 | 6064.13 | 01-OCT-10:09 | 1348.26 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 471.10 | 18-OCT-14:00 | 9725.58 | 10-OCT-11:10 |
November | 2879.63 | 04-NOV-14:09 | 6064.13 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 17147.04 | 26-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 6064.13 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 21294.47 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4186.65 | |||||
Maximum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 5394.27 | 24446.51 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.19 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.71 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6366.99 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 20-MAY-16:00 | 5735.15 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.56 | 29-JUN-15:00 | 4006.91 | 16-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 17-JUL-16:00 | 2388.98 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.22 | 05-AUG-16:00 | 3597.36 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.84 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.61 | 18-OCT-14:00 | 5531.04 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2388.98 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.19 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.71 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6366.99 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 20-MAY-16:00 | 5735.15 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.56 | 29-JUN-15:00 | 4006.91 | 16-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 17-JUL-16:00 | 2368.14 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.22 | 05-AUG-16:00 | 3581.09 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.84 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.61 | 18-OCT-14:00 | 5531.04 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2368.14 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13931.92 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11232.19 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 10846.71 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6366.98 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 20-MAY-16:00 | 5735.15 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.56 | 29-JUN-15:00 | 4006.91 | 16-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 17-JUL-16:00 | 2298.88 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2714.22 | 05-AUG-16:00 | 3523.24 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2468.84 | 02-SEP-15:00 | 4480.78 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.61 | 18-OCT-14:00 | 5531.04 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9760.20 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12156.59 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2298.88 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.67 | 13931.92 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 14365.77 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11629.40 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 11112.87 | 04-MAR-14:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6794.05 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1519.40 | 20-MAY-16:00 | 6320.37 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2158.00 | 29-JUN-15:00 | 4080.34 | 16-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3193.18 | 17-JUL-16:00 | 2173.65 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2835.18 | 05-AUG-16:00 | 3775.55 | 17-AUG-12:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2629.45 | 02-SEP-15:00 | 4826.72 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 285.01 | 18-OCT-14:00 | 5823.26 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 10187.06 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12382.24 | 31-DEC-15:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2173.65 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 3193.18 | 14365.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 24066.09 | 28-JAN-00:01 | 1799.77 | 50197.74 | 7490.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 641.98 |
February | 19510.97 | 04-FEB-00:01 | 1439.81 | 40158.19 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 725.77 |
March | 17396.25 | 04-MAR-00:01 | 1259.84 | 35138.42 | 5243.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 834.02 |
April | 10753.79 | 28-APR-23:12 | 899.88 | 25098.87 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 430.14 |
May | 13529.18 | 20-MAY-16:10 | 1799.77 | 9537.57 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2523.54 | 0.00 |
June | 16292.32 | 21-JUN-07:03 | 719.91 | 2007.91 | 299.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 483.68 |
July | 37711.02 | 18-JUL-07:02 | 899.88 | 2509.89 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 13.29 | 0.00 |
August | 36394.84 | 07-AUG-07:02 | 899.88 | 2509.89 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.30 |
September | 42465.90 | 05-SEP-07:02 | 899.88 | 2509.89 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 397.45 |
October | 12442.50 | 18-OCT-15:00 | 899.88 | 9537.57 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 487.99 | 0.00 |
November | 8623.93 | 10-NOV-01:00 | 179.98 | 5019.77 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 232.21 |
December | 20957.67 | 29-DEC-00:01 | 1619.79 | 45177.96 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.51 |
Annual Sum or Average | |||||||||||
Minimum of Months | 8623.93 | 179.98 | 2007.91 | 299.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 42465.90 | 1799.77 | 50197.74 | 7490.31 | 0.00 | 0.00 | 0.00 | 0.00 | 2523.54 | 834.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4644.46 | 11-JAN-20:42 | 2159.71 | 19075.14 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 317.32 |
February | 3816.88 | 28-FEB-21:00 | 539.93 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.77 |
March | 3768.66 | 14-MAR-20:00 | 539.93 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.63 |
April | 23488.84 | 25-APR-20:02 | 5399.28 | 47687.85 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 24749.17 | 31-MAY-20:57 | 2159.71 | 19075.14 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 |
June | 25412.23 | 04-JUN-19:38 | 2879.62 | 19075.14 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.54 |
July | 25957.57 | 27-JUL-20:37 | 5399.28 | 47687.85 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.08 |
August | 26167.31 | 14-AUG-20:40 | 4859.35 | 42919.07 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.76 |
September | 24828.37 | 23-SEP-18:06 | 8998.80 | 47687.85 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 222.26 |
October | 24759.99 | 15-OCT-17:57 | 4319.42 | 19075.14 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.78 |
November | 20606.47 | 04-NOV-18:15 | 1799.76 | 9537.57 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 314.50 |
December | 6321.73 | 15-DEC-18:52 | 4499.40 | 23843.93 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1205.62 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3768.66 | 539.93 | 4768.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 26167.31 | 8998.80 | 47687.85 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1205.62 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5241.12 | 17-JAN-18:25 | 3599.52 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1076.29 |
February | 5493.53 | 28-FEB-08:61 | 899.88 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1065.00 |
March | 4281.79 | 01-MAR-09:32 | 719.90 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 952.54 |
April | 4762.77 | 27-APR-07:01 | 899.88 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1022.39 |
May | 6417.94 | 20-MAY-16:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 0.00 |
June | 15469.91 | 22-JUN-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.18 |
July | 23256.93 | 27-JUL-06:01 | 0.00 | 1379.58 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.24 |
August | 22875.89 | 07-AUG-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.68 |
September | 22285.13 | 04-SEP-07:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.45 |
October | 5736.67 | 18-OCT-14:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 0.00 |
November | 5065.33 | 06-NOV-08:61 | 899.88 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 973.98 |
December | 7009.94 | 22-DEC-20:02 | 449.94 | 9854.12 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.79 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4281.79 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23256.93 | 3599.52 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 1076.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3639.51 | 04-JAN-20:33 | 269.96 | 5912.47 | 1123.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.67 |
February | 5199.19 | 23-FEB-11:35 | 719.90 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1063.58 |
March | 4071.82 | 30-MAR-10:33 | 539.93 | 11233.70 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1087.43 |
April | 4449.59 | 27-APR-09:02 | 719.90 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 994.65 |
May | 6278.78 | 20-MAY-16:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 0.00 |
June | 14958.36 | 22-JUN-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.17 |
July | 23393.48 | 27-JUL-06:01 | 0.00 | 1379.58 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.24 |
August | 23007.83 | 07-AUG-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.12 |
September | 22414.08 | 04-SEP-07:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.71 |
October | 5520.02 | 18-OCT-14:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 0.00 |
November | 4946.46 | 30-NOV-18:42 | 3599.52 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1063.41 |
December | 5278.62 | 14-DEC-20:03 | 359.95 | 7883.30 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 210.55 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3639.51 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23393.48 | 3599.52 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 1087.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5193.20 | 03-JAN-18:42 | 3599.52 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1148.14 |
February | 4355.43 | 16-FEB-19:12 | 1439.81 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1038.70 |
March | 4039.19 | 30-MAR-19:43 | 269.96 | 5912.47 | 1123.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240.10 |
April | 3657.75 | 13-APR-07:01 | 899.88 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 679.49 |
May | 6108.31 | 20-MAY-16:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 0.00 |
June | 12996.03 | 22-JUN-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.14 |
July | 21334.57 | 18-JUL-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.45 |
August | 23080.91 | 07-AUG-06:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.65 |
September | 22464.22 | 04-SEP-07:02 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 167.74 |
October | 5310.15 | 18-OCT-14:00 | 539.93 | 3744.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 | 0.00 |
November | 4920.43 | 20-NOV-20:33 | 359.95 | 7883.30 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.65 |
December | 5013.52 | 21-DEC-19:23 | 1439.81 | 14978.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1004.81 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3657.75 | 0.00 | 985.41 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23080.91 | 3599.52 | 19708.24 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.54 | 1148.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2072.43 | 14-JAN-12:00 | 2087.73 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 937.02 |
February | 5965.09 | 16-FEB-11:53 | 4643.40 | 18192.39 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1429.14 |
March | 4543.18 | 01-MAR-14:05 | 3599.53 | 12128.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6168.15 |
April | 5504.33 | 09-APR-10:43 | 1187.85 | 18192.39 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1325.10 |
May | 10850.27 | 20-MAY-16:00 | 2663.65 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2528.79 | 0.00 |
June | 13924.53 | 23-JUN-14:10 | 2483.68 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2931.89 | 0.00 |
July | 36107.09 | 17-JUL-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.40 |
August | 38179.94 | 07-AUG-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.96 |
September | 41323.17 | 05-SEP-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 391.73 |
October | 9475.31 | 18-OCT-14:40 | 2483.68 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 470.78 | 0.00 |
November | 4642.83 | 06-NOV-12:00 | 1547.80 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1097.28 |
December | 8626.00 | 06-DEC-20:42 | 1583.79 | 12766.59 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 277.51 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2072.43 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 41323.17 | 4643.40 | 18192.39 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 2931.89 | 6168.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2110.58 | 13-JAN-18:55 | 1223.84 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 648.45 |
February | 2155.15 | 27-FEB-18:40 | 611.92 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 621.80 |
March | 2794.12 | 21-MAR-10:53 | 2321.69 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 687.46 |
April | 4557.53 | 27-APR-19:53 | 791.89 | 6383.30 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.47 |
May | 5702.53 | 20-MAY-16:00 | 1331.82 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 0.00 |
June | 7321.67 | 23-JUN-14:00 | 899.88 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.03 | 0.00 |
July | 19506.07 | 17-JUL-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.67 |
August | 20599.97 | 07-AUG-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.56 |
September | 22367.24 | 05-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.33 |
October | 4924.56 | 18-OCT-14:40 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.42 | 0.00 |
November | 4929.36 | 11-NOV-11:53 | 791.89 | 12128.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1004.20 |
December | 3345.31 | 07-DEC-20:43 | 593.92 | 4787.47 | 1123.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 223.32 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2110.58 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22367.24 | 2321.69 | 12128.26 | 2696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.03 | 1004.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2024.91 | 13-JAN-18:35 | 1223.84 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 638.29 |
February | 2092.22 | 27-FEB-18:30 | 611.92 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 611.71 |
March | 3349.25 | 21-MAR-17:03 | 1835.76 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 807.74 |
April | 3206.56 | 20-APR-18:03 | 1403.81 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 791.09 |
May | 5597.10 | 20-MAY-16:00 | 1331.82 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 0.00 |
June | 7243.89 | 23-JUN-14:00 | 899.88 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.03 | 0.00 |
July | 19442.01 | 17-JUL-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.93 |
August | 20548.27 | 07-AUG-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.60 |
September | 22306.16 | 05-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.69 |
October | 4810.04 | 18-OCT-14:40 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.42 | 0.00 |
November | 2157.37 | 06-NOV-12:00 | 773.90 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 618.63 |
December | 887.89 | 07-DEC-12:00 | 773.90 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 574.65 |
Annual Sum or Average | |||||||||||
Minimum of Months | 887.89 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22306.16 | 1835.76 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.03 | 807.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 744.66 | 14-JAN-12:00 | 1043.86 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 516.90 |
February | 1863.34 | 27-FEB-18:10 | 611.92 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 586.67 |
March | 3556.71 | 24-MAR-19:03 | 593.92 | 4787.47 | 1123.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.20 |
April | 3121.16 | 18-APR-18:33 | 1403.81 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 793.61 |
May | 5331.35 | 20-MAY-16:00 | 1331.82 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.57 | 0.00 |
June | 7096.39 | 23-JUN-14:00 | 899.88 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.02 | 0.00 |
July | 19421.39 | 17-JUL-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.40 |
August | 20582.53 | 07-AUG-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.75 |
September | 22338.50 | 05-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 206.71 |
October | 4524.44 | 18-OCT-14:50 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 267.38 | 0.00 |
November | 3382.02 | 10-NOV-10:33 | 593.92 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 780.27 |
December | 3330.09 | 07-DEC-20:03 | 593.92 | 4787.47 | 1123.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.80 |
Annual Sum or Average | |||||||||||
Minimum of Months | 744.66 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22338.50 | 1403.81 | 9096.20 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 1800.02 | 793.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 487.91 |
February | 607.08 | 27-FEB-18:10 | 611.92 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 820.36 |
March | 2453.76 | 01-MAR-18:05 | 1223.84 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 712.85 |
April | 1129.89 | 08-APR-10:30 | 1043.86 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 532.05 |
May | 4919.03 | 20-MAY-16:00 | 1331.82 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1519.40 | 0.00 |
June | 7082.79 | 23-JUN-13:50 | 899.88 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1821.40 | 0.00 |
July | 14997.48 | 17-JUL-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.24 |
August | 12057.06 | 07-AUG-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.58 |
September | 18532.40 | 04-SEP-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 94.08 | 0.00 |
October | 4152.73 | 18-OCT-14:40 | 1241.83 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 284.82 | 0.00 |
November | 1143.15 | 03-NOV-11:00 | 773.90 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 583.56 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 638.33 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2395.25 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 159.58 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18532.40 | 1331.82 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1821.40 | 2395.25 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.120489E+12 | 89850.82 | 19-JAN-17:40 | 0.253246E+12 | 438828.41 | 08-JAN-17:00 |
February | 0.107498E+12 | 89852.21 | 16-FEB-18:49 | 0.143369E+12 | 339490.25 | 05-FEB-17:00 |
March | 0.118281E+12 | 89817.25 | 10-MAR-18:19 | 0.116110E+12 | 316225.60 | 04-MAR-17:00 |
April | 0.111385E+12 | 86587.55 | 07-APR-13:50 | 0.457711E+11 | 163403.38 | 29-APR-07:10 |
May | 0.116902E+12 | 110189.06 | 20-MAY-15:00 | 0.288213E+11 | 163090.11 | 08-MAY-07:10 |
June | 0.124513E+12 | 120877.24 | 29-JUN-14:00 | 0.125112E+10 | 58065.22 | 16-JUN-11:09 |
July | 0.142355E+12 | 139349.83 | 17-JUL-15:00 | 1791702.23 | 771.35 | 08-JUL-07:10 |
August | 0.139513E+12 | 131411.69 | 06-AUG-15:50 | 0.145968E+09 | 9789.56 | 18-AUG-07:10 |
September | 0.124125E+12 | 130183.44 | 02-SEP-14:00 | 0.561600E+10 | 70913.44 | 20-SEP-07:10 |
October | 0.118776E+12 | 105927.48 | 18-OCT-14:50 | 0.198760E+11 | 143171.76 | 10-OCT-07:10 |
November | 0.115833E+12 | 91455.54 | 17-NOV-19:40 | 0.827188E+11 | 281632.17 | 26-NOV-17:00 |
December | 0.120495E+12 | 91599.81 | 12-DEC-18:30 | 0.182838E+12 | 383244.22 | 31-DEC-17:00 |
Annual Sum or Average | 0.146016E+13 | 0.879765E+12 | ||||
Minimum of Months | 0.107498E+12 | 86587.55 | 1791702.23 | 771.35 | ||
Maximum of Months | 0.142355E+12 | 139349.83 | 0.253246E+12 | 438828.41 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.599295E+11 | 0.180801E+11 | 0.108804E+11 | 0.00 | 0.258016E+11 | 0.00 | 0.00 | 1430.72 | 0.00 | 0.00 | 0.00 | 0.579779E+10 | 0.00 |
February | 0.542583E+11 | 0.149371E+11 | 0.985143E+10 | 0.00 | 0.231867E+11 | 0.00 | 0.00 | 475949.39 | 0.00 | 0.00 | 0.00 | 0.526364E+10 | 0.00 |
March | 0.607812E+11 | 0.145865E+11 | 0.110523E+11 | 0.00 | 0.260061E+11 | 0.00 | 0.00 | 19547.53 | 0.00 | 0.00 | 0.00 | 0.585463E+10 | 0.00 |
April | 0.581548E+11 | 0.121448E+11 | 0.105581E+11 | 0.00 | 0.248642E+11 | 0.00 | 0.00 | 0.118127E+09 | 0.00 | 0.00 | 0.00 | 0.554466E+10 | 0.00 |
May | 0.603309E+11 | 0.107996E+11 | 0.109629E+11 | 0.00 | 0.259696E+11 | 0.00 | 0.00 | 0.320998E+10 | 0.00 | 0.00 | 0.00 | 0.562890E+10 | 0.00 |
June | 0.587570E+11 | 0.953731E+10 | 0.106818E+11 | 0.00 | 0.254557E+11 | 0.00 | 0.00 | 0.147439E+11 | 0.00 | 0.00 | 0.00 | 0.533703E+10 | 0.00 |
July | 0.597776E+11 | 0.102768E+11 | 0.108460E+11 | 0.00 | 0.257995E+11 | 0.00 | 0.00 | 0.302691E+11 | 0.00 | 0.00 | 0.00 | 0.538598E+10 | 0.00 |
August | 0.607324E+11 | 0.117623E+11 | 0.110454E+11 | 0.00 | 0.263088E+11 | 0.00 | 0.00 | 0.242609E+11 | 0.00 | 0.00 | 0.00 | 0.540354E+10 | 0.00 |
September | 0.582036E+11 | 0.132541E+11 | 0.105649E+11 | 0.00 | 0.251431E+11 | 0.00 | 0.00 | 0.117271E+11 | 0.00 | 0.00 | 0.00 | 0.523271E+10 | 0.00 |
October | 0.599295E+11 | 0.157213E+11 | 0.108804E+11 | 0.00 | 0.257422E+11 | 0.00 | 0.00 | 0.101458E+10 | 0.00 | 0.00 | 0.00 | 0.548813E+10 | 0.00 |
November | 0.580572E+11 | 0.169963E+11 | 0.105443E+11 | 0.00 | 0.248042E+11 | 0.00 | 0.00 | 4187048.04 | 0.00 | 0.00 | 0.00 | 0.542673E+10 | 0.00 |
December | 0.598264E+11 | 0.185837E+11 | 0.108529E+11 | 0.00 | 0.255128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.571874E+10 | 0.00 |
Annual Sum or Average | 0.708738E+12 | 0.166680E+12 | 0.128721E+12 | 0.304595E+12 | 0.00 | 0.853483E+11 | 0.660825E+11 | ||||||
Minimum of Months | 0.542583E+11 | 0.953731E+10 | 0.985143E+10 | 0.00 | 0.231867E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.523271E+10 | 0.00 |
Maximum of Months | 0.607812E+11 | 0.185837E+11 | 0.110523E+11 | 0.00 | 0.263088E+11 | 0.00 | 0.00 | 0.302691E+11 | 0.00 | 0.00 | 0.00 | 0.585463E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.253246E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.143369E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.116110E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.457711E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.288213E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.125112E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 1791702.23 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.145968E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.561600E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.198760E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.827188E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.182838E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.879765E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 1791702.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.253246E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 43732.45 | 01-JAN-11:09 | 10625.34 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:09 | 0.00 | 17694.73 | 01-JAN-09:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 43732.45 | 01-FEB-10:09 | 10625.34 | 01-FEB-00:10 | 8089.53 | 01-FEB-10:09 | 0.00 | 17694.73 | 24-FEB-10:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 43732.45 | 01-MAR-10:09 | 10625.34 | 01-MAR-00:10 | 8089.53 | 01-MAR-10:09 | 0.00 | 17694.73 | 10-MAR-12:00 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 43732.45 | 01-APR-09:09 | 10625.34 | 01-APR-00:10 | 8089.53 | 01-APR-09:09 | 0.00 | 17694.73 | 07-APR-14:39 | 0.00 | 0.00 | 01-APR-00:10 |
May | 43732.45 | 01-MAY-09:09 | 10625.34 | 01-MAY-00:10 | 8089.53 | 01-MAY-09:09 | 0.00 | 17694.73 | 01-MAY-07:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 43732.45 | 01-JUN-09:09 | 10625.34 | 01-JUN-00:10 | 8089.53 | 01-JUN-09:09 | 0.00 | 17694.73 | 01-JUN-07:10 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 43732.45 | 01-JUL-09:09 | 10625.34 | 01-JUL-00:10 | 8089.53 | 01-JUL-09:09 | 0.00 | 17694.73 | 01-JUL-07:10 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 43732.45 | 01-AUG-09:09 | 10625.34 | 01-AUG-00:10 | 8089.53 | 01-AUG-09:09 | 0.00 | 17694.73 | 01-AUG-07:10 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 43732.45 | 01-SEP-09:09 | 10625.34 | 01-SEP-00:10 | 8089.53 | 01-SEP-09:09 | 0.00 | 17694.73 | 18-SEP-14:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 43732.45 | 01-OCT-10:09 | 10625.34 | 01-OCT-00:10 | 8089.53 | 01-OCT-10:09 | 0.00 | 17694.73 | 01-OCT-08:30 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 43732.45 | 01-NOV-09:09 | 10625.34 | 01-NOV-00:10 | 8089.53 | 01-NOV-09:09 | 0.00 | 17694.73 | 01-NOV-07:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 43732.45 | 01-DEC-10:09 | 10625.34 | 01-DEC-00:10 | 8089.53 | 01-DEC-10:09 | 0.00 | 17694.73 | 01-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 43732.45 | 10625.34 | 8089.53 | 0.00 | 17694.73 | 0.00 | 0.00 | |||||
Maximum of Months | 43732.45 | 10625.34 | 8089.53 | 0.00 | 17694.73 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 2.38 | 14-JAN-21:40 | 0.00 | 0.00 | 0.00 | 11879.70 | 07-JAN-14:09 | 0.00 |
February | 136.88 | 26-FEB-23:10 | 0.00 | 0.00 | 0.00 | 9754.41 | 07-FEB-14:20 | 0.00 |
March | 15.33 | 26-MAR-20:10 | 0.00 | 0.00 | 0.00 | 10309.34 | 03-MAR-11:20 | 0.00 |
April | 10402.14 | 07-APR-13:00 | 0.00 | 0.00 | 0.00 | 9780.98 | 04-APR-09:50 | 0.00 |
May | 35687.13 | 20-MAY-15:00 | 0.00 | 0.00 | 0.00 | 9740.97 | 10-MAY-12:00 | 0.00 |
June | 45184.36 | 29-JUN-14:00 | 0.00 | 0.00 | 0.00 | 7630.02 | 16-JUN-12:30 | 0.00 |
July | 64387.48 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 9625.90 | 21-JUL-09:39 | 0.00 |
August | 58097.25 | 06-AUG-15:00 | 0.00 | 0.00 | 0.00 | 9709.83 | 24-AUG-13:09 | 0.00 |
September | 55666.11 | 02-SEP-14:00 | 0.00 | 0.00 | 0.00 | 11792.00 | 16-SEP-15:00 | 0.00 |
October | 25611.68 | 18-OCT-14:39 | 0.00 | 0.00 | 0.00 | 11799.19 | 18-OCT-16:30 | 0.00 |
November | 2449.45 | 17-NOV-21:10 | 0.00 | 0.00 | 0.00 | 11866.14 | 27-NOV-14:39 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 15683.58 | 12-DEC-14:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 7630.02 | 0.00 | ||
Maximum of Months | 64387.48 | 0.00 | 0.00 | 0.00 | 15683.58 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 89850.82 | 19-JAN-17:40 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 89852.21 | 16-FEB-18:49 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 89817.25 | 10-MAR-18:19 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 86587.55 | 07-APR-13:50 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 9456.54 | 0.00 |
May | 110189.06 | 20-MAY-15:00 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 35687.13 | 0.00 |
June | 120877.24 | 29-JUN-14:00 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 45184.36 | 0.00 |
July | 139349.83 | 17-JUL-15:00 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 64387.48 | 0.00 |
August | 131411.69 | 06-AUG-15:50 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 57583.76 | 0.00 |
September | 130183.44 | 02-SEP-14:00 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 55666.11 | 0.00 |
October | 105927.48 | 18-OCT-14:50 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 25600.19 | 0.00 |
November | 91455.54 | 17-NOV-19:40 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.08 | 0.00 |
December | 91599.81 | 12-DEC-18:30 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 86587.55 | 43732.45 | 8089.53 | 0.00 | 0.00 | 17694.73 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 139349.83 | 43732.45 | 8089.53 | 10625.34 | 0.00 | 17694.73 | 0.00 | 0.00 | 64387.48 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 438828.41 | 08-JAN-17:00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 339490.25 | 05-FEB-17:00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 316225.60 | 04-MAR-17:00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 163403.38 | 29-APR-07:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 163090.11 | 08-MAY-07:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 58065.22 | 16-JUN-11:09 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 771.35 | 08-JUL-07:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 9789.56 | 18-AUG-07:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 70913.44 | 20-SEP-07:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 143171.76 | 10-OCT-07:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 281632.17 | 26-NOV-17:00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 383244.22 | 31-DEC-17:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 771.35 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 438828.41 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 9.33 | 17.75 | 1.67 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2.67 | 20.01 | 0.67 | 20.42 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.83 | 20.36 | 0.33 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.33 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.67 | 20.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.00 | 19.45 | 0.33 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 17.00 | 18.77 | 3.00 | 20.38 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 9.33 | 20.54 | 1.67 | 20.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.00 | 20.28 | 1.00 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.83 | 20.45 | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.33 | 20.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 20.44 | 0.17 | 20.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 5.17 | 20.35 | 1.33 | 20.41 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.00 | 20.53 | 1.00 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.83 | 19.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.33 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.50 | 20.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3.00 | 20.08 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.83 | 20.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.67 | 17.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.67 | 20.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.00 | 18.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 5.83 | 18.53 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.67 | 20.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 4.83 | 17.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.67 | 20.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.33 | 19.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 7.33 | 18.04 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4.83 | 20.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 9.67 | 16.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.50 | 19.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.33 | 16.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.33 | 18.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 15.33 | 17.25 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 9.67 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.83 | 16.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.50 | 19.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.67 | 18.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.33 | 18.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 13.83 | 17.39 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 8.83 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.83 | 16.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.50 | 19.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.67 | 18.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.33 | 18.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 13.83 | 17.32 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 8.83 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 11.67 | 16.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.33 | 19.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 2.00 | 16.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.67 | 17.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 18.17 | 16.84 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 11.67 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 44.83 | 15.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 20.83 | 15.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 13.50 | 15.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 1.33 | 17.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2.17 | 15.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.17 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 7.00 | 16.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 23.67 | 15.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 113.50 | 15.49 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 44.83 | 20.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.05 | 374.17 | 21.03 | 374.17 | 21.03 |
February | 448.00 | 21.18 | 218.00 | 20.99 | 218.00 | 20.99 |
March | 496.00 | 21.10 | 175.17 | 20.99 | 175.17 | 20.99 |
April | 464.17 | 21.79 | 66.83 | 20.98 | 66.83 | 20.98 |
May | 330.00 | 21.98 | 66.17 | 22.55 | 31.17 | 21.04 |
June | 79.00 | 22.94 | 219.83 | 23.89 | 0.00 | 0.00 |
July | 16.83 | 23.72 | 379.00 | 23.89 | 1.67 | 23.89 |
August | 42.00 | 23.11 | 312.00 | 23.89 | 0.00 | 0.00 |
September | 151.33 | 22.36 | 195.50 | 23.87 | 6.67 | 23.43 |
October | 341.00 | 22.09 | 10.17 | 21.31 | 9.67 | 21.18 |
November | 475.00 | 21.52 | 114.83 | 21.11 | 114.83 | 21.11 |
December | 496.00 | 21.05 | 305.83 | 21.01 | 305.83 | 21.01 |
Annual Sum or Average | 3835.33 | 21.52 | 2437.50 | 22.36 | 1304.00 | 21.03 |
Minimum of Months | 16.83 | 21.05 | 10.17 | 20.98 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.72 | 379.00 | 23.89 | 374.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.30 | 289.50 | 21.09 | 289.50 | 21.09 |
February | 448.00 | 21.62 | 153.17 | 21.11 | 153.17 | 21.11 |
March | 496.00 | 21.60 | 106.33 | 21.13 | 106.33 | 21.13 |
April | 448.83 | 22.39 | 14.50 | 21.19 | 14.50 | 21.19 |
May | 311.50 | 22.42 | 39.67 | 23.18 | 10.33 | 21.20 |
June | 65.83 | 23.20 | 185.67 | 23.86 | 0.00 | 0.00 |
July | 15.67 | 23.47 | 329.00 | 23.86 | 0.00 | 0.00 |
August | 43.00 | 23.24 | 265.33 | 23.88 | 0.00 | 0.00 |
September | 133.50 | 22.72 | 177.17 | 23.86 | 5.67 | 23.82 |
October | 309.83 | 22.59 | 2.50 | 21.22 | 2.50 | 21.22 |
November | 474.00 | 22.01 | 57.83 | 21.13 | 57.83 | 21.13 |
December | 496.00 | 21.40 | 170.50 | 21.10 | 170.50 | 21.10 |
Annual Sum or Average | 3738.17 | 21.93 | 1791.17 | 22.63 | 810.33 | 21.13 |
Minimum of Months | 15.67 | 21.30 | 2.50 | 21.09 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.47 | 329.00 | 23.88 | 289.50 | 23.82 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 294.17 | 21.11 | 294.17 | 21.11 |
February | 336.00 | 21.23 | 171.33 | 21.11 | 171.33 | 21.11 |
March | 379.00 | 21.14 | 134.67 | 21.11 | 134.67 | 21.11 |
April | 355.67 | 21.78 | 41.33 | 21.11 | 41.33 | 21.11 |
May | 269.00 | 21.96 | 41.00 | 22.82 | 20.00 | 21.11 |
June | 63.50 | 22.86 | 143.33 | 24.15 | 0.00 | 0.00 |
July | 11.00 | 24.57 | 262.17 | 24.16 | 2.33 | 28.65 |
August | 36.33 | 23.18 | 196.83 | 24.19 | 1.67 | 28.88 |
September | 132.50 | 22.39 | 131.00 | 24.14 | 7.50 | 25.13 |
October | 283.17 | 22.05 | 7.00 | 21.53 | 6.33 | 21.11 |
November | 360.00 | 21.39 | 94.17 | 21.11 | 94.17 | 21.11 |
December | 369.00 | 21.11 | 231.33 | 21.11 | 231.33 | 21.11 |
Annual Sum or Average | 2966.17 | 21.54 | 1748.33 | 22.43 | 1004.83 | 21.17 |
Minimum of Months | 11.00 | 21.11 | 7.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.57 | 294.17 | 24.19 | 294.17 | 28.88 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 312.50 | 21.11 | 312.50 | 21.11 |
February | 336.00 | 21.21 | 195.17 | 21.11 | 195.17 | 21.11 |
March | 379.00 | 21.13 | 150.83 | 21.11 | 150.83 | 21.11 |
April | 360.00 | 21.74 | 50.83 | 21.11 | 50.83 | 21.11 |
May | 276.17 | 21.94 | 46.50 | 22.56 | 26.17 | 21.11 |
June | 68.83 | 22.88 | 139.17 | 24.15 | 0.00 | 0.00 |
July | 11.83 | 24.37 | 259.83 | 24.16 | 2.00 | 28.78 |
August | 37.83 | 23.15 | 189.83 | 24.20 | 1.67 | 28.88 |
September | 145.00 | 22.44 | 127.17 | 24.13 | 8.00 | 24.88 |
October | 302.67 | 22.06 | 10.83 | 21.31 | 10.33 | 21.11 |
November | 360.00 | 21.33 | 113.00 | 21.11 | 113.00 | 21.11 |
December | 369.00 | 21.11 | 254.67 | 21.11 | 254.67 | 21.11 |
Annual Sum or Average | 3017.33 | 21.54 | 1850.33 | 22.33 | 1125.17 | 21.16 |
Minimum of Months | 11.83 | 21.11 | 10.83 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.37 | 312.50 | 24.20 | 312.50 | 28.88 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 323.50 | 21.11 | 323.50 | 21.11 |
February | 336.00 | 21.19 | 209.17 | 21.11 | 209.17 | 21.11 |
March | 379.00 | 21.12 | 168.83 | 21.11 | 168.83 | 21.11 |
April | 360.00 | 21.68 | 62.00 | 21.11 | 62.00 | 21.11 |
May | 282.67 | 21.92 | 52.17 | 22.28 | 33.67 | 21.11 |
June | 77.17 | 22.91 | 131.83 | 24.16 | 0.00 | 0.00 |
July | 13.33 | 24.26 | 254.67 | 24.16 | 2.00 | 28.74 |
August | 41.33 | 23.11 | 184.00 | 24.20 | 1.33 | 29.07 |
September | 150.83 | 22.42 | 124.67 | 24.12 | 8.50 | 24.70 |
October | 313.83 | 22.04 | 13.67 | 21.11 | 13.67 | 21.11 |
November | 360.00 | 21.29 | 125.00 | 21.11 | 125.00 | 21.11 |
December | 369.00 | 21.11 | 270.67 | 21.11 | 270.67 | 21.11 |
Annual Sum or Average | 3054.17 | 21.53 | 1920.17 | 22.25 | 1218.33 | 21.16 |
Minimum of Months | 13.33 | 21.11 | 13.67 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.26 | 323.50 | 24.20 | 323.50 | 29.07 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 315.33 | 21.11 | 315.33 | 21.11 |
February | 308.00 | 21.18 | 240.33 | 21.11 | 240.33 | 21.11 |
March | 348.00 | 21.12 | 193.50 | 21.11 | 193.50 | 21.11 |
April | 330.00 | 21.62 | 77.33 | 21.11 | 77.33 | 21.11 |
May | 275.33 | 21.95 | 52.33 | 21.76 | 41.50 | 21.11 |
June | 89.67 | 23.06 | 106.00 | 24.00 | 0.00 | 0.00 |
July | 11.00 | 24.17 | 222.00 | 24.01 | 1.50 | 28.85 |
August | 34.17 | 23.05 | 156.33 | 24.00 | 1.33 | 29.01 |
September | 151.33 | 22.47 | 111.00 | 24.04 | 8.67 | 24.59 |
October | 307.00 | 22.04 | 13.00 | 21.11 | 13.00 | 21.11 |
November | 330.00 | 21.23 | 141.00 | 21.11 | 141.00 | 21.11 |
December | 338.00 | 21.11 | 283.00 | 21.11 | 283.00 | 21.11 |
Annual Sum or Average | 2862.50 | 21.54 | 1911.17 | 22.03 | 1316.50 | 21.15 |
Minimum of Months | 11.00 | 21.11 | 13.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 24.17 | 315.33 | 24.04 | 315.33 | 29.01 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 316.50 | 21.11 | 316.50 | 21.11 |
February | 308.00 | 21.18 | 242.67 | 21.11 | 242.67 | 21.11 |
March | 348.00 | 21.12 | 198.83 | 21.11 | 198.83 | 21.11 |
April | 330.00 | 21.62 | 81.50 | 21.11 | 81.50 | 21.11 |
May | 282.17 | 22.00 | 51.83 | 21.59 | 44.17 | 21.11 |
June | 98.83 | 23.14 | 88.00 | 24.02 | 0.00 | 0.00 |
July | 13.83 | 24.07 | 195.50 | 24.03 | 1.33 | 28.83 |
August | 40.00 | 23.18 | 125.83 | 24.03 | 1.17 | 29.04 |
September | 155.00 | 22.51 | 96.83 | 24.05 | 8.83 | 24.38 |
October | 315.50 | 22.11 | 14.67 | 21.11 | 14.67 | 21.11 |
November | 330.00 | 21.24 | 145.50 | 21.11 | 145.50 | 21.11 |
December | 338.00 | 21.11 | 283.17 | 21.11 | 283.17 | 21.11 |
Annual Sum or Average | 2899.33 | 21.57 | 1840.83 | 21.93 | 1338.33 | 21.15 |
Minimum of Months | 13.83 | 21.11 | 14.67 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 24.07 | 316.50 | 24.05 | 316.50 | 29.04 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 317.67 | 21.11 | 317.67 | 21.11 |
February | 308.00 | 21.17 | 247.83 | 21.11 | 247.83 | 21.11 |
March | 348.00 | 21.11 | 209.67 | 21.11 | 209.67 | 21.11 |
April | 330.00 | 21.60 | 88.17 | 21.11 | 88.17 | 21.11 |
May | 287.00 | 22.00 | 52.67 | 21.45 | 47.50 | 21.11 |
June | 105.50 | 23.14 | 82.50 | 24.02 | 0.00 | 0.00 |
July | 16.50 | 23.99 | 186.33 | 24.03 | 1.33 | 28.81 |
August | 42.50 | 23.20 | 120.00 | 24.03 | 1.17 | 29.02 |
September | 158.00 | 22.50 | 93.83 | 24.04 | 9.33 | 24.25 |
October | 320.17 | 22.10 | 15.83 | 21.11 | 15.83 | 21.11 |
November | 330.00 | 21.23 | 151.50 | 21.11 | 151.50 | 21.11 |
December | 338.00 | 21.11 | 286.50 | 21.11 | 286.50 | 21.11 |
Annual Sum or Average | 2923.67 | 21.58 | 1852.50 | 21.88 | 1376.50 | 21.15 |
Minimum of Months | 16.50 | 21.11 | 15.83 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.99 | 317.67 | 24.04 | 317.67 | 29.02 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 325.17 | 21.11 | 325.17 | 21.11 |
February | 308.00 | 21.16 | 264.83 | 21.11 | 264.83 | 21.11 |
March | 348.00 | 21.11 | 240.50 | 21.11 | 240.50 | 21.11 |
April | 330.00 | 21.54 | 109.00 | 21.11 | 109.00 | 21.11 |
May | 298.83 | 22.00 | 60.17 | 21.31 | 56.67 | 21.11 |
June | 123.00 | 23.10 | 73.83 | 24.02 | 0.00 | 0.00 |
July | 22.50 | 23.84 | 174.17 | 24.04 | 1.33 | 28.78 |
August | 48.17 | 23.18 | 113.50 | 24.03 | 1.00 | 29.12 |
September | 164.33 | 22.46 | 90.17 | 23.99 | 10.50 | 23.78 |
October | 326.17 | 22.05 | 20.50 | 21.11 | 20.50 | 21.11 |
November | 330.00 | 21.21 | 165.17 | 21.11 | 165.17 | 21.11 |
December | 338.00 | 21.11 | 301.17 | 21.11 | 301.17 | 21.11 |
Annual Sum or Average | 2977.00 | 21.58 | 1938.17 | 21.80 | 1495.83 | 21.14 |
Minimum of Months | 22.50 | 21.11 | 20.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.84 | 325.17 | 24.04 | 325.17 | 29.12 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 335.67 | 21.11 | 335.67 | 21.11 |
February | 308.00 | 21.14 | 284.67 | 21.11 | 284.67 | 21.11 |
March | 348.00 | 21.11 | 315.17 | 21.11 | 315.17 | 21.11 |
April | 330.00 | 21.42 | 202.00 | 21.11 | 202.00 | 21.11 |
May | 326.50 | 22.01 | 109.67 | 21.15 | 108.83 | 21.11 |
June | 159.67 | 22.94 | 59.83 | 23.87 | 3.00 | 21.11 |
July | 39.33 | 23.57 | 152.83 | 24.05 | 1.33 | 28.80 |
August | 69.33 | 23.21 | 105.33 | 24.04 | 1.00 | 29.16 |
September | 178.50 | 22.38 | 86.50 | 23.84 | 15.83 | 23.07 |
October | 335.33 | 21.94 | 49.00 | 21.11 | 49.00 | 21.11 |
November | 330.00 | 21.17 | 213.33 | 21.11 | 213.33 | 21.11 |
December | 338.00 | 21.11 | 330.33 | 21.11 | 330.33 | 21.11 |
Annual Sum or Average | 3102.67 | 21.58 | 2244.33 | 21.63 | 1860.17 | 21.14 |
Minimum of Months | 39.33 | 21.11 | 49.00 | 21.11 | 1.00 | 21.11 |
Maximum of Months | 348.00 | 23.57 | 335.67 | 24.05 | 335.67 | 29.16 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.02500 | 10.27662 | -0.6851 | 15.59707 |
February | 448.00000 | 21.16245 | 13.49038 | -0.5669 | 12.75584 |
March | 496.00000 | 21.08700 | 15.23540 | -0.5415 | 11.68662 |
April | 480.00000 | 21.84596 | 20.07414 | -0.2889 | 8.41158 |
May | 496.00000 | 22.60475 | 23.66231 | -1.0616 | 32.54019 |
June | 480.00000 | 23.73009 | 30.80919 | -0.5320 | 12.11448 |
July | 496.00000 | 23.88592 | 33.55721 | -0.3883 | 8.45172 |
August | 496.00000 | 23.82472 | 30.05431 | -0.4461 | 9.81970 |
September | 480.00000 | 23.40275 | 31.02650 | -0.6300 | 16.31630 |
October | 496.00000 | 22.64183 | 22.32760 | -0.0106 | 6.79814 |
November | 480.00000 | 21.52372 | 16.56719 | -0.3836 | 9.38017 |
December | 496.00000 | 21.03863 | 12.57339 | -0.6121 | 13.43475 |
Annual Sum or Average | 5840.00000 | 22.32046 | 21.67215 | -0.5124 | 13.12880 |
Minimum of Months | 448.00000 | 21.02500 | 10.27662 | -1.0616 | 6.79814 |
Maximum of Months | 496.00000 | 23.88592 | 33.55721 | -0.0106 | 32.54019 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.27410 | 11.07170 | -0.5843 | 13.05532 |
February | 448.00000 | 21.59288 | 13.95407 | -0.4414 | 10.36865 |
March | 496.00000 | 21.57310 | 15.91198 | -0.4063 | 9.24979 |
April | 480.00000 | 22.46047 | 20.06818 | -0.1406 | 6.91575 |
May | 496.00000 | 22.93202 | 23.62583 | -0.9507 | 27.23578 |
June | 480.00000 | 23.75137 | 30.71698 | -0.5253 | 11.53076 |
July | 496.00000 | 23.82360 | 33.57758 | -0.4220 | 9.01006 |
August | 496.00000 | 23.78807 | 30.17075 | -0.4698 | 10.08711 |
September | 480.00000 | 23.53172 | 30.90053 | -0.6027 | 14.65877 |
October | 496.00000 | 23.05822 | 22.17581 | 0.07222 | 6.46274 |
November | 480.00000 | 22.00749 | 16.92481 | -0.2713 | 8.00030 |
December | 496.00000 | 21.37144 | 13.32503 | -0.5065 | 11.04078 |
Annual Sum or Average | 5840.00000 | 22.60156 | 21.90315 | -0.4379 | 11.49008 |
Minimum of Months | 448.00000 | 21.27410 | 11.07170 | -0.9507 | 6.46274 |
Maximum of Months | 496.00000 | 23.82360 | 33.57758 | 0.07222 | 27.23578 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10972 | 10.04264 | -0.6680 | 14.75499 |
February | 336.00000 | 21.23113 | 13.02050 | -0.5570 | 12.15712 |
March | 379.00000 | 21.14064 | 15.16722 | -0.5255 | 11.08718 |
April | 360.00000 | 21.80441 | 19.86915 | -0.3016 | 8.23312 |
May | 375.00000 | 22.53506 | 23.32404 | -1.1101 | 34.58636 |
June | 366.00000 | 23.80496 | 30.49913 | -0.5431 | 12.56635 |
July | 369.00000 | 24.03885 | 33.08093 | -0.3891 | 8.77944 |
August | 379.00000 | 23.93206 | 29.82226 | -0.4571 | 10.34333 |
September | 360.00000 | 23.38641 | 31.11605 | -0.6759 | 18.04870 |
October | 371.00000 | 22.49732 | 22.40602 | -0.0639 | 6.84247 |
November | 360.00000 | 21.38868 | 16.75645 | -0.4278 | 9.61539 |
December | 369.00000 | 21.11006 | 12.53581 | -0.6033 | 12.93504 |
Annual Sum or Average | 4395.00000 | 22.34044 | 21.52289 | -0.5275 | 13.36164 |
Minimum of Months | 336.00000 | 21.10972 | 10.04264 | -1.1101 | 6.84247 |
Maximum of Months | 379.00000 | 24.03885 | 33.08093 | -0.0639 | 34.58636 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10979 | 10.04260 | -0.6829 | 15.16013 |
February | 336.00000 | 21.20788 | 13.04135 | -0.5779 | 12.58591 |
March | 379.00000 | 21.13000 | 15.17759 | -0.5428 | 11.45934 |
April | 360.00000 | 21.73133 | 19.96344 | -0.3324 | 8.56577 |
May | 375.00000 | 22.47930 | 23.40725 | -1.1446 | 36.10322 |
June | 366.00000 | 23.79023 | 30.52603 | -0.5549 | 12.89177 |
July | 369.00000 | 24.03605 | 33.08692 | -0.3931 | 8.85144 |
August | 379.00000 | 23.92474 | 29.83684 | -0.4633 | 10.50525 |
September | 360.00000 | 23.35241 | 31.17401 | -0.6952 | 18.77317 |
October | 371.00000 | 22.40843 | 22.52778 | -0.0952 | 6.95004 |
November | 360.00000 | 21.32964 | 16.83246 | -0.4564 | 10.05380 |
December | 369.00000 | 21.11017 | 12.53583 | -0.6195 | 13.35096 |
Annual Sum or Average | 4395.00000 | 22.30980 | 21.56546 | -0.5471 | 13.80375 |
Minimum of Months | 336.00000 | 21.10979 | 10.04260 | -1.1446 | 6.95004 |
Maximum of Months | 379.00000 | 24.03605 | 33.08692 | -0.0952 | 36.10322 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10975 | 10.04253 | -0.6949 | 15.50271 |
February | 336.00000 | 21.19347 | 13.05411 | -0.5936 | 12.93746 |
March | 379.00000 | 21.12447 | 15.18293 | -0.5557 | 11.75934 |
April | 360.00000 | 21.67693 | 20.03375 | -0.3557 | 8.84537 |
May | 375.00000 | 22.42789 | 23.48676 | -1.1744 | 37.40010 |
June | 366.00000 | 23.76817 | 30.56479 | -0.5695 | 13.30793 |
July | 369.00000 | 24.03086 | 33.10191 | -0.4003 | 8.97943 |
August | 379.00000 | 23.91400 | 29.85775 | -0.4725 | 10.73221 |
September | 360.00000 | 23.31787 | 31.23864 | -0.7134 | 19.44181 |
October | 371.00000 | 22.33086 | 22.63503 | -0.1204 | 7.04749 |
November | 360.00000 | 21.28975 | 16.88478 | -0.4762 | 10.38929 |
December | 369.00000 | 21.10978 | 12.53621 | -0.6326 | 13.70096 |
Annual Sum or Average | 4395.00000 | 22.28350 | 21.60438 | -0.5638 | 14.20381 |
Minimum of Months | 336.00000 | 21.10975 | 10.04253 | -1.1744 | 7.04749 |
Maximum of Months | 379.00000 | 24.03086 | 33.10191 | -0.1204 | 37.40010 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10993 | 10.60195 | -0.7313 | 16.57745 |
February | 308.00000 | 21.17603 | 13.59676 | -0.6294 | 13.81307 |
March | 348.00000 | 21.11530 | 15.80291 | -0.5832 | 12.39470 |
April | 330.00000 | 21.61475 | 20.62811 | -0.3899 | 9.27412 |
May | 344.00000 | 22.34629 | 24.00229 | -1.2230 | 39.46770 |
June | 336.00000 | 23.69073 | 31.00335 | -0.5977 | 13.89381 |
July | 338.00000 | 23.93752 | 33.46567 | -0.4220 | 9.18586 |
August | 348.00000 | 23.82829 | 30.37114 | -0.4927 | 11.00625 |
September | 330.00000 | 23.25702 | 31.87138 | -0.7357 | 20.19584 |
October | 340.00000 | 22.22240 | 23.31895 | -0.1536 | 7.15353 |
November | 330.00000 | 21.23223 | 17.54107 | -0.5124 | 11.06009 |
December | 338.00000 | 21.10981 | 13.11851 | -0.6683 | 14.67128 |
Annual Sum or Average | 4030.00000 | 22.22906 | 22.16433 | -0.5955 | 14.92564 |
Minimum of Months | 308.00000 | 21.10981 | 10.60195 | -1.2230 | 7.15353 |
Maximum of Months | 348.00000 | 23.93752 | 33.46567 | -0.1536 | 39.46770 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10976 | 10.54818 | -0.7241 | 16.32885 |
February | 308.00000 | 21.17608 | 13.54561 | -0.6279 | 13.73746 |
March | 348.00000 | 21.11560 | 15.74802 | -0.5861 | 12.44648 |
April | 330.00000 | 21.61667 | 20.57083 | -0.3977 | 9.38300 |
May | 344.00000 | 22.34944 | 23.94501 | -1.2382 | 40.07566 |
June | 336.00000 | 23.69518 | 30.95315 | -0.6202 | 14.42410 |
July | 338.00000 | 23.93885 | 33.42278 | -0.4493 | 9.66516 |
August | 348.00000 | 23.83199 | 30.31699 | -0.5181 | 11.50051 |
September | 330.00000 | 23.26584 | 31.81724 | -0.7557 | 20.70252 |
October | 340.00000 | 22.23666 | 23.24310 | -0.1628 | 7.19975 |
November | 330.00000 | 21.23847 | 17.47845 | -0.5156 | 11.10912 |
December | 338.00000 | 21.10989 | 13.06264 | -0.6642 | 14.53665 |
Annual Sum or Average | 4030.00000 | 22.23275 | 22.10845 | -0.6056 | 15.12938 |
Minimum of Months | 308.00000 | 21.10976 | 10.54818 | -1.2382 | 7.19975 |
Maximum of Months | 348.00000 | 23.93885 | 33.42278 | -0.1628 | 40.07566 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10984 | 10.54811 | -0.7269 | 16.40959 |
February | 308.00000 | 21.17172 | 13.54900 | -0.6328 | 13.84624 |
March | 348.00000 | 21.11463 | 15.74924 | -0.5913 | 12.57122 |
April | 330.00000 | 21.59577 | 20.59889 | -0.4083 | 9.53128 |
May | 344.00000 | 22.32599 | 23.98379 | -1.2536 | 40.75004 |
June | 336.00000 | 23.67788 | 30.98550 | -0.6328 | 14.81589 |
July | 338.00000 | 23.93615 | 33.43089 | -0.4554 | 9.78928 |
August | 348.00000 | 23.82838 | 30.32457 | -0.5245 | 11.65614 |
September | 330.00000 | 23.24869 | 31.85188 | -0.7666 | 21.10330 |
October | 340.00000 | 22.20413 | 23.29118 | -0.1745 | 7.26295 |
November | 330.00000 | 21.22933 | 17.49060 | -0.5221 | 11.23216 |
December | 338.00000 | 21.10995 | 13.06261 | -0.6680 | 14.63787 |
Annual Sum or Average | 4030.00000 | 22.22175 | 22.12634 | -0.6137 | 15.33821 |
Minimum of Months | 308.00000 | 21.10984 | 10.54811 | -1.2536 | 7.26295 |
Maximum of Months | 348.00000 | 23.93615 | 33.43089 | -0.1745 | 40.75004 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10994 | 10.54774 | -0.7391 | 16.78070 |
February | 308.00000 | 21.16007 | 13.55744 | -0.6504 | 14.28110 |
March | 348.00000 | 21.11217 | 15.75156 | -0.6096 | 13.03171 |
April | 330.00000 | 21.53493 | 20.67832 | -0.4406 | 10.03384 |
May | 344.00000 | 22.25799 | 24.10093 | -1.2977 | 42.71833 |
June | 336.00000 | 23.61931 | 31.08494 | -0.6684 | 16.01504 |
July | 338.00000 | 23.92622 | 33.45647 | -0.4680 | 10.08166 |
August | 348.00000 | 23.81525 | 30.34778 | -0.5382 | 12.04559 |
September | 330.00000 | 23.19852 | 31.95161 | -0.7944 | 22.19923 |
October | 340.00000 | 22.11929 | 23.41512 | -0.2043 | 7.46768 |
November | 330.00000 | 21.20630 | 17.52079 | -0.5411 | 11.62111 |
December | 338.00000 | 21.10982 | 13.06253 | -0.6824 | 15.04264 |
Annual Sum or Average | 4030.00000 | 22.18986 | 22.17718 | -0.6368 | 15.98263 |
Minimum of Months | 308.00000 | 21.10982 | 10.54774 | -1.2977 | 7.46768 |
Maximum of Months | 348.00000 | 23.92622 | 33.45647 | -0.2043 | 42.71833 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10995 | 10.46629 | -0.8118 | 19.20909 |
February | 308.00000 | 21.13780 | 13.49806 | -0.7279 | 16.52362 |
March | 348.00000 | 21.10984 | 15.63730 | -0.6899 | 15.27517 |
April | 330.00000 | 21.41727 | 20.71830 | -0.5417 | 12.04356 |
May | 344.00000 | 22.10019 | 24.38403 | -1.4260 | 48.64498 |
June | 336.00000 | 23.45338 | 31.41346 | -0.7685 | 19.74450 |
July | 338.00000 | 23.88928 | 33.53793 | -0.4967 | 10.91824 |
August | 348.00000 | 23.77207 | 30.38540 | -0.5718 | 13.19868 |
September | 330.00000 | 23.08367 | 32.08741 | -0.8643 | 25.19335 |
October | 340.00000 | 21.96332 | 23.54207 | -0.2755 | 8.24262 |
November | 330.00000 | 21.16852 | 17.49506 | -0.6062 | 13.17983 |
December | 338.00000 | 21.10996 | 13.00215 | -0.7514 | 17.16031 |
Annual Sum or Average | 4030.00000 | 22.11854 | 22.23548 | -0.7116 | 18.31957 |
Minimum of Months | 308.00000 | 21.10984 | 10.46629 | -1.4260 | 8.24262 |
Maximum of Months | 348.00000 | 23.88928 | 33.53793 | -0.2755 | 48.64498 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 1565.58 | 508.84 | 2.50 | 1565.58 | 0.00 | 0.00 | 0.00 | 27-FEB-15:30 | 0.00 | 01-FEB-00:03 | 0.33 | 27-FEB-15:30 | 0.33 | 27-FEB-15:30 | 0.00 | 27-FEB-15:20 | 0.11 | 27-FEB-15:30 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 99751617.51 | 31901675.70 | 36.48 | 99751617.51 | 0.00 | 0.00 | 0.23 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 7232.23 | 07-APR-14:00 | 7232.23 | 07-APR-14:00 | 0.00 | 06-APR-16:00 | 2309.07 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.244347E+10 | 0.770410E+09 | 146.25 | 0.243537E+10 | 8095851.34 | 0.00 | 0.56 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 19732.45 | 20-MAY-16:10 | 19732.45 | 20-MAY-16:10 | 367.59 | 19-MAY-11:30 | 6552.29 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
June | 0.995877E+10 | 0.315312E+10 | 321.50 | 0.954090E+10 | 0.417873E+09 | 0.00 | 0.67 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 24645.12 | 20-JUN-17:00 | 23578.76 | 29-JUN-15:00 | 3784.28 | 20-JUN-18:40 | 8081.54 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.200760E+11 | 0.647748E+10 | 433.33 | 0.195807E+11 | 0.495346E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 42605.07 | 17-JUL-07:02 | 41979.14 | 18-JUL-07:02 | 12912.32 | 19-JUL-07:03 | 11341.63 | 17-JUL-16:10 | 0.00 | 01-JUL-00:03 |
August | 0.159774E+11 | 0.515506E+10 | 396.47 | 0.159026E+11 | 74802968.67 | 0.00 | 0.94 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 37849.94 | 07-AUG-07:02 | 37849.94 | 07-AUG-07:02 | 2149.49 | 09-AUG-07:03 | 10497.99 | 06-AUG-16:01 | 0.00 | 01-AUG-00:10 |
September | 0.840698E+10 | 0.266125E+10 | 255.45 | 0.799572E+10 | 0.411258E+09 | 0.00 | 1.00 | 05-SEP-07:02 | 0.00 | 01-SEP-00:10 | 41504.53 | 05-SEP-07:02 | 38512.05 | 04-SEP-07:02 | 13393.73 | 07-SEP-07:02 | 10151.82 | 05-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 0.822607E+09 | 0.255414E+09 | 95.62 | 0.822607E+09 | 0.00 | 0.00 | 0.47 | 18-OCT-14:50 | 0.00 | 01-OCT-00:10 | 15908.25 | 18-OCT-15:00 | 15908.25 | 18-OCT-15:00 | 0.00 | 15-OCT-15:00 | 4919.49 | 18-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 4803.00 | 1561.05 | 10.53 | 4803.00 | 0.00 | 0.00 | 0.00 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 | 0.35 | 04-NOV-14:00 | 0.35 | 04-NOV-14:00 | 0.00 | 04-NOV-13:50 | 0.11 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.577851E+11 | 0.185046E+11 | 1698.13 | 0.563777E+11 | 0.140737E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.200760E+11 | 0.647748E+10 | 433.33 | 0.195807E+11 | 0.495346E+09 | 0.00 | 1.00 | 0.00 | 42605.07 | 41979.14 | 13393.73 | 11341.63 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 4333.91 | 1430.72 | 0.17 | 4333.91 | 0.00 | 0.00 | 0.00 | 14-JAN-21:40 | 0.00 | 01-JAN-00:10 | 7.22 | 14-JAN-21:40 | 7.22 | 14-JAN-21:40 | 0.00 | 01-JAN-00:10 | 2.38 | 14-JAN-21:40 | 0.00 | 01-JAN-00:10 |
February | 1446812.90 | 474665.43 | 7.64 | 1446812.90 | 0.00 | 0.00 | 0.03 | 26-FEB-23:10 | 0.00 | 01-FEB-00:03 | 417.63 | 26-FEB-23:10 | 417.63 | 26-FEB-23:10 | 0.00 | 01-FEB-00:03 | 136.88 | 26-FEB-23:10 | 0.00 | 01-FEB-00:03 |
March | 59246.41 | 19547.53 | 0.50 | 59246.41 | 0.00 | 0.00 | 0.00 | 26-MAR-20:10 | 0.00 | 01-MAR-00:10 | 46.45 | 26-MAR-20:10 | 46.45 | 26-MAR-20:10 | 0.00 | 01-MAR-00:10 | 15.33 | 26-MAR-20:10 | 0.00 | 01-MAR-00:10 |
April | 0.115890E+09 | 32253627.38 | 42.45 | 0.115890E+09 | 0.00 | 0.00 | 1.00 | 06-APR-20:02 | 0.00 | 01-APR-00:05 | 21313.94 | 06-APR-20:02 | 21313.94 | 06-APR-20:02 | 0.00 | 06-APR-15:10 | 4898.90 | 06-APR-20:02 | 0.00 | 01-APR-00:05 |
May | 0.163089E+10 | 0.457292E+09 | 128.91 | 0.161947E+10 | 11421391.50 | 0.00 | 1.00 | 02-MAY-20:05 | 0.00 | 01-MAY-00:10 | 21723.46 | 20-MAY-18:20 | 21723.46 | 20-MAY-18:20 | 3637.09 | 20-MAY-21:20 | 5256.59 | 20-MAY-18:20 | 0.00 | 01-MAY-00:10 |
June | 0.588192E+10 | 0.169679E+10 | 288.15 | 0.562902E+10 | 0.252895E+09 | 0.00 | 1.00 | 03-JUN-18:01 | 0.00 | 01-JUN-00:10 | 22739.12 | 21-JUN-20:01 | 21725.58 | 25-JUN-17:46 | 7368.35 | 21-JUN-22:55 | 5401.46 | 18-JUN-19:11 | 0.00 | 01-JUN-00:10 |
July | 0.111036E+11 | 0.330557E+10 | 378.01 | 0.107933E+11 | 0.310286E+09 | 0.00 | 1.00 | 01-JUL-18:01 | 0.00 | 01-JUL-00:03 | 23412.80 | 18-JUL-21:58 | 21988.84 | 18-JUL-07:02 | 9940.02 | 18-JUL-21:58 | 5506.58 | 17-JUL-16:00 | 0.00 | 01-JUL-00:03 |
August | 0.894131E+10 | 0.265675E+10 | 348.60 | 0.888054E+10 | 60773097.75 | 0.00 | 1.00 | 02-AUG-20:05 | 0.00 | 01-AUG-00:10 | 22013.17 | 08-AUG-22:43 | 21619.00 | 07-AUG-22:01 | 4623.54 | 15-AUG-20:40 | 5290.55 | 08-AUG-22:01 | 0.00 | 01-AUG-00:10 |
September | 0.470657E+10 | 0.137494E+10 | 220.50 | 0.446782E+10 | 0.238756E+09 | 0.00 | 1.00 | 01-SEP-20:01 | 0.00 | 01-SEP-00:10 | 23106.45 | 06-SEP-20:01 | 21692.28 | 24-SEP-17:16 | 8114.88 | 06-SEP-23:00 | 5350.05 | 06-SEP-20:01 | 0.00 | 01-SEP-00:10 |
October | 0.511110E+09 | 0.146962E+09 | 92.21 | 0.511110E+09 | 0.00 | 0.00 | 1.00 | 02-OCT-20:02 | 0.00 | 01-OCT-00:10 | 21313.94 | 02-OCT-20:02 | 21313.94 | 02-OCT-20:02 | 0.00 | 15-OCT-13:10 | 4898.90 | 02-OCT-20:02 | 0.00 | 01-OCT-00:10 |
November | 16613291.15 | 4184917.53 | 11.39 | 16613291.15 | 0.00 | 0.00 | 1.00 | 04-NOV-18:15 | 0.00 | 01-NOV-00:10 | 21313.94 | 04-NOV-18:15 | 21313.94 | 04-NOV-18:15 | 0.00 | 19-NOV-21:20 | 4898.90 | 04-NOV-18:15 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.329094E+11 | 0.967524E+10 | 1518.52 | 0.320352E+11 | 0.874131E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.111036E+11 | 0.330557E+10 | 378.01 | 0.107933E+11 | 0.310286E+09 | 0.00 | 1.00 | 0.00 | 23412.80 | 21988.84 | 9940.02 | 5506.58 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 691.58 | 211.94 | 2.33 | 691.58 | 0.00 | 0.00 | 0.00 | 27-FEB-15:30 | 0.00 | 01-FEB-00:03 | 0.13 | 27-FEB-15:30 | 0.13 | 27-FEB-15:30 | 0.00 | 27-FEB-15:00 | 0.04 | 27-FEB-15:30 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 41950851.24 | 12687261.16 | 26.17 | 41950851.24 | 0.00 | 0.00 | 0.22 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 3491.68 | 07-APR-14:00 | 3491.68 | 07-APR-14:00 | 0.00 | 06-APR-17:30 | 1053.25 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.886325E+09 | 0.265636E+09 | 99.62 | 0.883476E+09 | 2849052.68 | 0.00 | 0.55 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 9631.10 | 20-MAY-16:00 | 9631.10 | 20-MAY-16:00 | 181.83 | 19-MAY-11:20 | 3036.68 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.393884E+10 | 0.118597E+10 | 237.31 | 0.378972E+10 | 0.149123E+09 | 0.00 | 0.76 | 22-JUN-06:02 | 0.00 | 01-JUN-00:10 | 15104.09 | 22-JUN-06:02 | 11751.51 | 23-JUN-14:00 | 4873.01 | 22-JUN-06:02 | 3771.56 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.776110E+10 | 0.237809E+10 | 308.26 | 0.758953E+10 | 0.171567E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22183.73 | 19-JUL-06:03 | 19369.28 | 18-JUL-06:02 | 7321.37 | 19-JUL-06:03 | 5311.70 | 17-JUL-16:10 | 0.00 | 01-JUL-00:03 |
August | 0.628043E+10 | 0.192261E+10 | 288.77 | 0.624974E+10 | 30699208.83 | 0.00 | 1.00 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 | 20392.05 | 07-AUG-06:02 | 20392.05 | 07-AUG-06:02 | 2661.51 | 01-AUG-06:01 | 4803.18 | 06-AUG-16:00 | 0.00 | 01-AUG-00:10 |
September | 0.309933E+10 | 0.928120E+09 | 175.53 | 0.293993E+10 | 0.159402E+09 | 0.00 | 1.00 | 04-SEP-07:02 | 0.00 | 01-SEP-00:10 | 21211.59 | 07-SEP-06:02 | 20140.86 | 04-SEP-07:02 | 7748.13 | 07-SEP-06:02 | 4902.46 | 07-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.322703E+09 | 95131702.55 | 59.67 | 0.322703E+09 | 0.00 | 0.00 | 0.44 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 7528.61 | 18-OCT-14:00 | 7528.61 | 18-OCT-14:00 | 0.00 | 15-OCT-13:20 | 2208.70 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 1116.09 | 342.03 | 2.67 | 1116.09 | 0.00 | 0.00 | 0.00 | 04-NOV-15:10 | 0.00 | 01-NOV-00:10 | 0.17 | 04-NOV-15:10 | 0.17 | 04-NOV-15:10 | 0.00 | 04-NOV-13:50 | 0.05 | 04-NOV-15:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.223307E+11 | 0.678825E+10 | 1200.32 | 0.218170E+11 | 0.513640E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.776110E+10 | 0.237809E+10 | 308.26 | 0.758953E+10 | 0.171567E+09 | 0.00 | 1.00 | 0.00 | 22183.73 | 20392.05 | 7748.13 | 5311.70 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 666.84 | 204.36 | 2.00 | 666.84 | 0.00 | 0.00 | 0.00 | 27-FEB-14:40 | 0.00 | 01-FEB-00:03 | 0.17 | 27-FEB-14:40 | 0.17 | 27-FEB-14:40 | 0.00 | 27-FEB-15:00 | 0.05 | 27-FEB-14:40 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 33672616.96 | 10223751.52 | 21.83 | 33672616.96 | 0.00 | 0.00 | 0.20 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 3228.83 | 07-APR-14:00 | 3228.83 | 07-APR-14:00 | 0.00 | 07-APR-14:50 | 978.12 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.843213E+09 | 0.253533E+09 | 96.75 | 0.840635E+09 | 2578249.23 | 0.00 | 0.54 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 9495.68 | 20-MAY-16:00 | 9495.68 | 20-MAY-16:00 | 172.28 | 19-MAY-11:30 | 3000.92 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.387261E+10 | 0.116818E+10 | 234.14 | 0.372595E+10 | 0.146658E+09 | 0.00 | 0.73 | 22-JUN-06:02 | 0.00 | 01-JUN-00:10 | 14317.51 | 22-JUN-06:02 | 11694.10 | 23-JUN-14:00 | 4625.57 | 22-JUN-06:02 | 3759.14 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.771755E+10 | 0.236721E+10 | 306.41 | 0.754640E+10 | 0.171153E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22247.58 | 19-JUL-06:03 | 19432.00 | 18-JUL-06:02 | 7342.03 | 19-JUL-06:03 | 5315.18 | 17-JUL-16:10 | 0.00 | 01-JUL-00:03 |
August | 0.622728E+10 | 0.190873E+10 | 287.64 | 0.619710E+10 | 30176063.78 | 0.00 | 1.00 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 | 20450.44 | 07-AUG-06:02 | 20450.44 | 07-AUG-06:02 | 2711.04 | 01-AUG-06:01 | 4798.37 | 06-AUG-16:00 | 0.00 | 01-AUG-00:10 |
September | 0.305381E+10 | 0.915774E+09 | 172.77 | 0.289585E+10 | 0.157966E+09 | 0.00 | 1.00 | 04-SEP-07:02 | 0.00 | 01-SEP-00:10 | 21272.46 | 07-SEP-06:02 | 20210.09 | 04-SEP-07:02 | 7773.64 | 07-SEP-06:02 | 4916.53 | 07-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.290752E+09 | 85992217.16 | 55.69 | 0.290752E+09 | 0.00 | 0.00 | 0.43 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 7315.68 | 18-OCT-14:00 | 7315.68 | 18-OCT-14:00 | 0.00 | 15-OCT-14:30 | 2153.65 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 742.13 | 227.43 | 1.67 | 742.13 | 0.00 | 0.00 | 0.00 | 04-NOV-14:20 | 0.00 | 01-NOV-00:10 | 0.18 | 04-NOV-14:20 | 0.18 | 04-NOV-14:20 | 0.00 | 01-NOV-00:10 | 0.06 | 04-NOV-14:20 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.220389E+11 | 0.670965E+10 | 1178.91 | 0.215304E+11 | 0.508532E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.771755E+10 | 0.236721E+10 | 306.41 | 0.754640E+10 | 0.171153E+09 | 0.00 | 1.00 | 0.00 | 22247.58 | 20450.44 | 7773.64 | 5315.18 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 846.98 | 259.56 | 1.33 | 846.98 | 0.00 | 0.00 | 0.00 | 27-FEB-15:40 | 0.00 | 01-FEB-00:03 | 0.22 | 27-FEB-15:40 | 0.22 | 27-FEB-15:40 | 0.00 | 27-FEB-15:10 | 0.07 | 27-FEB-15:40 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 26675001.37 | 8130464.05 | 17.33 | 26675001.37 | 0.00 | 0.00 | 0.19 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 2978.29 | 07-APR-14:00 | 2978.29 | 07-APR-14:00 | 0.00 | 07-APR-16:10 | 906.05 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.798147E+09 | 0.240868E+09 | 90.67 | 0.795904E+09 | 2242367.04 | 0.00 | 0.53 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 9334.36 | 20-MAY-16:00 | 9334.36 | 20-MAY-16:00 | 162.38 | 19-MAY-11:30 | 2959.29 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.377219E+10 | 0.114133E+10 | 229.23 | 0.362974E+10 | 0.142447E+09 | 0.00 | 0.65 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 11583.70 | 23-JUN-14:00 | 11583.70 | 23-JUN-14:00 | 3670.62 | 22-JUN-06:02 | 3732.41 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.758687E+10 | 0.233366E+10 | 303.31 | 0.741998E+10 | 0.166895E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22389.79 | 19-JUL-06:03 | 19532.62 | 18-JUL-06:02 | 7414.24 | 19-JUL-06:03 | 5307.52 | 17-JUL-16:10 | 0.00 | 01-JUL-00:03 |
August | 0.610717E+10 | 0.187737E+10 | 285.80 | 0.607849E+10 | 28682107.37 | 0.00 | 1.00 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 | 20585.29 | 07-AUG-06:02 | 20585.29 | 07-AUG-06:02 | 2384.96 | 09-AUG-06:02 | 4782.13 | 06-AUG-16:00 | 0.00 | 01-AUG-00:10 |
September | 0.298270E+10 | 0.896846E+09 | 168.71 | 0.282811E+10 | 0.154582E+09 | 0.00 | 1.00 | 04-SEP-07:02 | 0.00 | 01-SEP-00:10 | 21070.08 | 05-SEP-06:02 | 20322.70 | 04-SEP-07:02 | 7327.63 | 07-SEP-06:02 | 4862.70 | 05-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.263555E+09 | 78190421.23 | 53.61 | 0.263555E+09 | 0.00 | 0.00 | 0.42 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 7114.91 | 18-OCT-14:00 | 7114.91 | 18-OCT-14:00 | 0.00 | 18-OCT-15:40 | 2102.21 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.215373E+11 | 0.657640E+10 | 1149.99 | 0.210425E+11 | 0.494848E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.758687E+10 | 0.233366E+10 | 303.31 | 0.741998E+10 | 0.166895E+09 | 0.00 | 1.00 | 0.00 | 22389.79 | 20585.29 | 7414.24 | 5307.52 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 305.42 | 99.27 | 0.67 | 305.42 | 0.00 | 0.00 | 0.00 | 27-FEB-15:40 | 0.00 | 01-FEB-00:03 | 0.20 | 27-FEB-15:40 | 0.20 | 27-FEB-15:40 | 0.00 | 27-FEB-15:40 | 0.06 | 27-FEB-15:40 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 32185229.83 | 10466707.67 | 14.00 | 32185229.83 | 0.00 | 0.00 | 0.15 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 4578.81 | 07-APR-14:00 | 4578.81 | 07-APR-14:00 | 0.00 | 06-APR-16:30 | 1489.71 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.135550E+10 | 0.436667E+09 | 80.83 | 0.135121E+10 | 4289022.21 | 0.00 | 0.51 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 16973.29 | 20-MAY-16:00 | 16973.29 | 20-MAY-16:00 | 318.52 | 19-MAY-11:40 | 5722.20 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.684806E+10 | 0.220921E+10 | 221.96 | 0.655624E+10 | 0.291811E+09 | 0.00 | 0.64 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 21243.02 | 29-JUN-15:00 | 21243.02 | 29-JUN-15:00 | 3533.79 | 20-JUN-15:00 | 7333.83 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.138464E+11 | 0.454308E+10 | 304.35 | 0.135240E+11 | 0.322407E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 41531.32 | 19-JUL-07:03 | 39669.07 | 18-JUL-07:02 | 13218.98 | 19-JUL-07:03 | 10491.05 | 17-JUL-16:00 | 0.00 | 01-JUL-00:03 |
August | 0.111366E+11 | 0.365172E+10 | 288.75 | 0.110822E+11 | 54486754.14 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 38873.44 | 07-AUG-07:02 | 38873.44 | 07-AUG-07:02 | 2190.49 | 09-AUG-07:03 | 9806.06 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.530081E+10 | 0.169677E+10 | 156.01 | 0.499763E+10 | 0.303181E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 39636.63 | 04-SEP-08:62 | 39636.63 | 04-SEP-08:62 | 12559.34 | 06-SEP-07:01 | 10529.65 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.419660E+09 | 0.132742E+09 | 46.58 | 0.419660E+09 | 0.00 | 0.00 | 0.40 | 18-OCT-14:30 | 0.00 | 01-OCT-00:10 | 12756.24 | 18-OCT-14:40 | 12756.24 | 18-OCT-14:40 | 0.00 | 18-OCT-14:10 | 4016.22 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.389393E+11 | 0.126807E+11 | 1113.17 | 0.379631E+11 | 0.976175E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.138464E+11 | 0.454308E+10 | 304.35 | 0.135240E+11 | 0.322407E+09 | 0.00 | 1.00 | 0.00 | 41531.32 | 39669.07 | 13218.98 | 10529.65 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 15242124.94 | 4683223.12 | 13.50 | 15242124.94 | 0.00 | 0.00 | 0.15 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 2379.30 | 07-APR-14:00 | 2379.30 | 07-APR-14:00 | 0.00 | 24-APR-16:00 | 731.22 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.702647E+09 | 0.214133E+09 | 77.58 | 0.700762E+09 | 1884123.45 | 0.00 | 0.50 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 8951.22 | 20-MAY-16:00 | 8951.22 | 20-MAY-16:00 | 151.91 | 19-MAY-11:30 | 2857.74 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.356442E+10 | 0.108899E+10 | 220.33 | 0.341686E+10 | 0.147566E+09 | 0.00 | 0.62 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 11156.98 | 29-JUN-15:00 | 11156.98 | 29-JUN-15:00 | 1844.89 | 20-JUN-15:20 | 3653.61 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.723065E+10 | 0.224856E+10 | 302.59 | 0.706774E+10 | 0.162911E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22019.25 | 17-JUL-07:02 | 21624.09 | 18-JUL-07:02 | 6140.35 | 19-JUL-07:03 | 5264.65 | 18-JUL-07:02 | 0.00 | 01-JUL-00:03 |
August | 0.580362E+10 | 0.180362E+10 | 287.58 | 0.577765E+10 | 25964646.82 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 21197.71 | 07-AUG-07:02 | 21197.71 | 07-AUG-07:02 | 970.36 | 09-AUG-07:03 | 5022.44 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.275218E+10 | 0.834841E+09 | 154.69 | 0.259917E+10 | 0.153012E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 21613.37 | 04-SEP-08:62 | 21613.37 | 04-SEP-08:62 | 5314.21 | 06-SEP-07:01 | 5413.63 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.211196E+09 | 63136304.33 | 47.33 | 0.211196E+09 | 0.00 | 0.00 | 0.39 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 6752.13 | 18-OCT-14:40 | 6752.13 | 18-OCT-14:40 | 0.00 | 15-OCT-13:10 | 2010.37 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.202800E+11 | 0.625796E+10 | 1103.59 | 0.197886E+11 | 0.491338E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.723065E+10 | 0.224856E+10 | 302.59 | 0.706774E+10 | 0.162911E+09 | 0.00 | 1.00 | 0.00 | 22019.25 | 21624.09 | 6140.35 | 5413.63 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 13633272.78 | 4195849.44 | 12.83 | 13633272.78 | 0.00 | 0.00 | 0.14 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 2265.11 | 07-APR-14:00 | 2265.11 | 07-APR-14:00 | 0.00 | 07-APR-15:20 | 697.35 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.681767E+09 | 0.208153E+09 | 73.83 | 0.679969E+09 | 1798330.79 | 0.00 | 0.50 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 8844.41 | 20-MAY-16:00 | 8844.41 | 20-MAY-16:00 | 147.57 | 19-MAY-11:40 | 2827.82 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.350106E+10 | 0.107124E+10 | 217.71 | 0.335559E+10 | 0.145465E+09 | 0.00 | 0.62 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 11072.94 | 29-JUN-15:00 | 11072.94 | 29-JUN-15:00 | 1833.04 | 20-JUN-15:20 | 3630.27 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.714681E+10 | 0.222532E+10 | 301.28 | 0.698593E+10 | 0.160877E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22015.12 | 17-JUL-07:02 | 21618.97 | 18-JUL-07:02 | 5860.19 | 19-JUL-07:03 | 5263.48 | 18-JUL-07:02 | 0.00 | 01-JUL-00:03 |
August | 0.573249E+10 | 0.178381E+10 | 286.00 | 0.570708E+10 | 25401670.00 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 21191.74 | 07-AUG-07:02 | 21191.74 | 07-AUG-07:02 | 930.39 | 09-AUG-07:03 | 5020.96 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.271304E+10 | 0.823989E+09 | 152.19 | 0.256188E+10 | 0.151163E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 21607.58 | 04-SEP-08:62 | 21607.58 | 04-SEP-08:62 | 5098.69 | 07-SEP-14:50 | 5412.29 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.200967E+09 | 60165635.40 | 44.58 | 0.200967E+09 | 0.00 | 0.00 | 0.39 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 6636.21 | 18-OCT-14:40 | 6636.21 | 18-OCT-14:40 | 0.00 | 15-OCT-14:30 | 1979.16 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.199898E+11 | 0.617687E+10 | 1088.43 | 0.195051E+11 | 0.484705E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.714681E+10 | 0.222532E+10 | 301.28 | 0.698593E+10 | 0.160877E+09 | 0.00 | 1.00 | 0.00 | 22015.12 | 21618.97 | 5860.19 | 5412.29 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 9471070.41 | 2930083.48 | 9.67 | 9471070.41 | 0.00 | 0.00 | 0.12 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 1934.10 | 07-APR-14:00 | 1934.10 | 07-APR-14:00 | 0.00 | 07-APR-13:30 | 598.69 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.629559E+09 | 0.193273E+09 | 68.42 | 0.628003E+09 | 1556013.72 | 0.00 | 0.48 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 8592.76 | 20-MAY-16:00 | 8592.76 | 20-MAY-16:00 | 135.66 | 19-MAY-11:40 | 2760.49 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.335317E+10 | 0.103057E+10 | 208.22 | 0.321287E+10 | 0.140302E+09 | 0.00 | 0.60 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 10900.79 | 29-JUN-15:00 | 10900.79 | 29-JUN-15:00 | 1805.11 | 20-JUN-15:20 | 3588.05 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.697918E+10 | 0.218121E+10 | 296.44 | 0.682343E+10 | 0.155752E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 22235.37 | 17-JUL-07:02 | 20417.97 | 17-JUL-07:02 | 5002.53 | 19-JUL-07:03 | 5304.18 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 |
August | 0.558972E+10 | 0.174586E+10 | 280.29 | 0.556579E+10 | 23936995.08 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 21399.27 | 07-AUG-07:02 | 21399.27 | 07-AUG-07:02 | 797.38 | 09-AUG-07:03 | 5069.90 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.263074E+10 | 0.801893E+09 | 146.81 | 0.248375E+10 | 0.146987E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 21737.11 | 04-SEP-08:62 | 21737.11 | 04-SEP-08:62 | 5018.90 | 07-SEP-14:50 | 5451.24 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.176719E+09 | 53123609.67 | 41.08 | 0.176719E+09 | 0.00 | 0.00 | 0.37 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 6364.64 | 18-OCT-14:50 | 6364.64 | 18-OCT-14:50 | 0.00 | 18-OCT-13:00 | 1907.57 | 18-OCT-14:50 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.193686E+11 | 0.600886E+10 | 1050.93 | 0.189000E+11 | 0.468533E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.697918E+10 | 0.218121E+10 | 296.44 | 0.682343E+10 | 0.155752E+09 | 0.00 | 1.00 | 0.00 | 22235.37 | 21737.11 | 5018.90 | 5451.24 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 2080559.60 | 654313.59 | 1.17 | 2080559.60 | 0.00 | 0.00 | 0.05 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 969.70 | 07-APR-14:00 | 969.70 | 07-APR-14:00 | 0.00 | 07-APR-14:00 | 305.21 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.545212E+09 | 0.170017E+09 | 54.83 | 0.543940E+09 | 1272042.00 | 0.00 | 0.42 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 8305.19 | 20-MAY-16:00 | 8305.19 | 20-MAY-16:00 | 130.43 | 19-MAY-12:10 | 2714.36 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.320350E+10 | 0.998468E+09 | 191.97 | 0.306678E+10 | 0.136713E+09 | 0.00 | 0.55 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 10947.57 | 23-JUN-14:00 | 10947.57 | 23-JUN-14:00 | 1802.04 | 20-JUN-15:20 | 3660.42 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.697604E+10 | 0.220895E+10 | 289.09 | 0.682167E+10 | 0.154375E+09 | 0.00 | 0.77 | 17-JUL-07:02 | 0.00 | 01-JUL-00:03 | 17777.83 | 17-JUL-07:02 | 16231.87 | 17-JUL-07:02 | 1886.74 | 19-JUL-12:10 | 5458.59 | 17-JUL-16:00 | 0.00 | 01-JUL-00:03 |
August | 0.554480E+10 | 0.175533E+10 | 270.08 | 0.552294E+10 | 21855425.84 | 0.00 | 0.69 | 06-AUG-16:00 | 0.00 | 01-AUG-00:10 | 13982.02 | 06-AUG-16:00 | 13982.02 | 06-AUG-16:00 | 704.32 | 22-AUG-14:20 | 4868.29 | 06-AUG-16:00 | 0.00 | 01-AUG-00:10 |
September | 0.256381E+10 | 0.792632E+09 | 135.90 | 0.242624E+10 | 0.137562E+09 | 0.00 | 0.93 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 22144.71 | 04-SEP-08:62 | 22144.71 | 04-SEP-08:62 | 4887.13 | 07-SEP-14:50 | 5683.67 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.143936E+09 | 43720076.05 | 37.67 | 0.143936E+09 | 0.00 | 0.00 | 0.32 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 6117.49 | 18-OCT-14:40 | 6117.49 | 18-OCT-14:40 | 0.00 | 15-OCT-14:10 | 1858.21 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.189794E+11 | 0.596977E+10 | 980.71 | 0.185276E+11 | 0.451777E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.697604E+10 | 0.220895E+10 | 289.09 | 0.682167E+10 | 0.154375E+09 | 0.00 | 0.93 | 0.00 | 22144.71 | 22144.71 | 4887.13 | 5683.67 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.29 | 147.94 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.55 | 109.81 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.53 | 97.12 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.50 | 72.27 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.49 | 58.61 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.40 | 41.66 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.93 | 32.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.05 | 37.10 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.43 | 52.92 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.14 | 75.14 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.00 | 93.84 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.90 | 126.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.29 | 78.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.49 | 32.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.14 | 147.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.29 | 147.94 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.55 | 109.81 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.53 | 97.12 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.50 | 72.27 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.49 | 58.61 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.40 | 41.66 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.93 | 32.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.05 | 37.10 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.43 | 52.92 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.14 | 75.14 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.00 | 93.84 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.90 | 126.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.29 | 78.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.49 | 32.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.14 | 147.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.29 | 147.94 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.55 | 109.81 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.53 | 97.12 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.50 | 72.27 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.49 | 58.61 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.40 | 41.66 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.93 | 32.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.05 | 37.10 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.43 | 52.92 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.14 | 75.14 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.00 | 93.84 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.90 | 126.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.29 | 78.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.49 | 32.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.14 | 147.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.29 | 147.94 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.55 | 109.81 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.53 | 97.12 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.50 | 72.27 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.49 | 58.61 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.40 | 41.66 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.93 | 32.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.05 | 37.10 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.43 | 52.92 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.14 | 75.14 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.00 | 93.84 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.90 | 126.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.29 | 78.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.49 | 32.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.14 | 147.94 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 123.51 | 176.00 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 170.75 | 130.75 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 142.98 | 115.64 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 105.51 | 86.15 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 83.80 | 69.87 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 91.97 | 49.74 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 115.32 | 38.97 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 147.98 | 44.36 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 170.22 | 63.20 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 173.63 | 89.66 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 150.70 | 111.83 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 121.79 | 150.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 132.91 | 93.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 83.80 | 38.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 173.63 | 176.00 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 123.51 | 176.00 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 170.75 | 130.75 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 142.98 | 115.64 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 105.51 | 86.15 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 83.80 | 69.87 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 91.97 | 49.74 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 115.32 | 38.97 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 147.98 | 44.36 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 170.22 | 63.20 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 173.63 | 89.66 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 150.70 | 111.83 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 121.79 | 150.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 132.91 | 93.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 83.80 | 38.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 173.63 | 176.00 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.06 | 153.05 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 139.82 | 115.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.03 | 102.62 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 85.96 | 77.49 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 68.32 | 61.97 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.76 | 42.88 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.83 | 32.87 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.83 | 37.58 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 140.80 | 54.44 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 142.97 | 78.20 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 123.62 | 98.03 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 99.64 | 131.54 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.25 | 82.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 68.32 | 32.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 142.97 | 153.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.06 | 153.05 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 139.82 | 115.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.03 | 102.62 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 85.96 | 77.49 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 68.32 | 61.97 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.76 | 42.88 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.83 | 32.87 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.83 | 37.58 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 140.80 | 54.44 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 142.97 | 78.20 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 123.62 | 98.03 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 99.64 | 131.54 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.25 | 82.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 68.32 | 32.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 142.97 | 153.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 122.04 | 182.05 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 168.69 | 136.91 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 141.18 | 122.14 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 103.66 | 92.32 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 82.40 | 73.82 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 91.21 | 51.17 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 115.20 | 39.32 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 147.72 | 44.92 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 169.47 | 64.97 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 172.25 | 93.25 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 149.07 | 116.76 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 120.29 | 156.56 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 131.67 | 97.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 82.40 | 39.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 172.25 | 182.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.45 | 148.08 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 140.56 | 110.42 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.56 | 98.35 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 86.79 | 73.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 68.91 | 59.58 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.78 | 43.24 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.36 | 34.42 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.56 | 38.78 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 140.89 | 54.13 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 143.83 | 75.24 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 124.51 | 93.52 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.14 | 126.83 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.64 | 79.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 68.91 | 34.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 143.83 | 148.08 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.45 | 148.08 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 140.56 | 110.42 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.56 | 98.35 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 86.79 | 73.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 68.91 | 59.58 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.78 | 43.24 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.36 | 34.42 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.56 | 38.78 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 140.89 | 54.13 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 143.83 | 75.24 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 124.51 | 93.52 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.14 | 126.83 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.64 | 79.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 68.91 | 34.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 143.83 | 148.08 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 121.85 | 175.16 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 168.66 | 130.69 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 141.06 | 116.42 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 104.10 | 87.14 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 82.66 | 70.58 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 90.75 | 51.28 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.03 | 40.90 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 146.61 | 46.06 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 168.67 | 64.22 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 172.33 | 89.22 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 149.32 | 110.77 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 120.24 | 150.12 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 131.42 | 94.26 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 82.66 | 40.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 172.33 | 175.16 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.65 | 146.60 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 140.91 | 108.86 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.83 | 96.93 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.22 | 71.96 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.29 | 58.40 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.95 | 42.85 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.42 | 34.35 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.63 | 38.62 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.08 | 53.54 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.25 | 73.86 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 124.90 | 91.86 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.38 | 125.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.90 | 78.49 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.29 | 34.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.25 | 146.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.65 | 146.60 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 140.91 | 108.86 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 117.83 | 96.93 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.22 | 71.96 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.29 | 58.40 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 75.95 | 42.85 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.42 | 34.35 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.63 | 38.62 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.08 | 53.54 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.25 | 73.86 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 124.90 | 91.86 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.38 | 125.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 109.90 | 78.49 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.29 | 34.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.25 | 146.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 122.09 | 173.39 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 169.08 | 128.84 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 141.39 | 114.73 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 104.61 | 85.26 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 83.12 | 69.18 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 90.95 | 50.82 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.10 | 40.81 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 146.69 | 45.86 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 168.89 | 63.52 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 172.84 | 87.59 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 149.79 | 108.81 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 120.53 | 148.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 131.74 | 92.97 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 83.12 | 40.81 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 172.84 | 173.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.80 | 145.81 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.17 | 108.00 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.03 | 96.14 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.54 | 71.01 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.62 | 57.60 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.16 | 42.41 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.54 | 34.03 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.76 | 38.26 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.26 | 53.03 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.58 | 73.00 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.18 | 90.95 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.57 | 124.37 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.13 | 77.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.62 | 34.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.58 | 145.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 101.80 | 145.81 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.17 | 108.00 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.03 | 96.14 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 87.54 | 71.01 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 69.62 | 57.60 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.16 | 42.41 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.54 | 34.03 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.76 | 38.26 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.26 | 53.03 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 144.58 | 73.00 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.18 | 90.95 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 100.57 | 124.37 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.13 | 77.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 69.62 | 34.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 144.58 | 145.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 122.28 | 172.45 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 169.40 | 127.82 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 141.63 | 113.79 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 105.00 | 84.13 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 83.52 | 68.23 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 91.21 | 50.29 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.25 | 40.43 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 146.84 | 45.44 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 169.12 | 62.91 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 173.24 | 86.56 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 150.13 | 107.72 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 120.77 | 147.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 132.01 | 92.13 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 83.52 | 40.43 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 173.24 | 172.45 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.80 | 142.39 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.48 | 105.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 119.00 | 93.43 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.67 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.46 | 55.57 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.61 | 41.11 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.63 | 32.97 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.96 | 37.13 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.78 | 51.74 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.55 | 71.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.27 | 88.48 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.65 | 121.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.91 | 75.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.46 | 32.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.55 | 142.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.80 | 142.39 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.48 | 105.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 119.00 | 93.43 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.67 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.46 | 55.57 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.61 | 41.11 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.63 | 32.97 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.96 | 37.13 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.78 | 51.74 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.55 | 71.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.27 | 88.48 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.65 | 121.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.91 | 75.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.46 | 32.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.55 | 142.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.80 | 142.39 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.48 | 105.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 119.00 | 93.43 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.67 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.46 | 55.57 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.61 | 41.11 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.63 | 32.97 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.96 | 37.13 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.78 | 51.74 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.55 | 71.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.27 | 88.48 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.65 | 121.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.91 | 75.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.46 | 32.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.55 | 142.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.80 | 142.39 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.48 | 105.03 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 119.00 | 93.43 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.67 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.46 | 55.57 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.61 | 41.11 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.63 | 32.97 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.96 | 37.13 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.78 | 51.74 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.55 | 71.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.27 | 88.48 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.65 | 121.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.91 | 75.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.46 | 32.97 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.55 | 142.39 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 123.46 | 168.44 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 170.96 | 124.34 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 142.79 | 110.61 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 106.07 | 81.37 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 84.53 | 65.85 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 91.75 | 48.77 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.37 | 39.18 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.10 | 44.11 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 169.73 | 61.40 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 174.38 | 84.35 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 151.41 | 104.82 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 122.04 | 143.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 132.94 | 89.61 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 84.53 | 39.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 174.38 | 168.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 123.46 | 168.44 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 170.96 | 124.34 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 142.79 | 110.61 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 106.07 | 81.37 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 84.53 | 65.85 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 91.75 | 48.77 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.37 | 39.18 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.10 | 44.11 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 169.73 | 61.40 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 174.38 | 84.35 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 151.41 | 104.82 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 122.04 | 143.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 132.94 | 89.61 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 84.53 | 39.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 174.38 | 168.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.28 | 143.48 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.94 | 105.75 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.59 | 93.97 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.28 | 68.88 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.43 | 55.67 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.76 | 41.00 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.92 | 32.72 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.11 | 36.91 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.69 | 51.70 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.27 | 71.23 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.89 | 88.94 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.16 | 122.01 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.72 | 75.92 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.43 | 32.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.27 | 143.48 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.28 | 143.48 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 141.94 | 105.75 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.59 | 93.97 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.28 | 68.88 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.43 | 55.67 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.76 | 41.00 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 95.92 | 32.72 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.11 | 36.91 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.69 | 51.70 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.27 | 71.23 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 125.89 | 88.94 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.16 | 122.01 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.72 | 75.92 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.43 | 32.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.27 | 143.48 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 122.87 | 169.69 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 170.33 | 125.16 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 142.32 | 111.21 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 105.89 | 81.60 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 84.51 | 65.95 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 91.94 | 48.63 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.72 | 38.88 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.28 | 43.84 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 169.64 | 61.34 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 174.07 | 84.47 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 150.99 | 105.34 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 121.48 | 144.40 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 132.73 | 89.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 84.51 | 38.88 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 174.07 | 169.69 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.32 | 143.29 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.02 | 105.50 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.67 | 93.65 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.43 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.63 | 55.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.96 | 40.69 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.04 | 32.53 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.21 | 36.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.81 | 51.42 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.43 | 70.84 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.00 | 88.62 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.21 | 121.77 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.84 | 75.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.63 | 32.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.43 | 143.29 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.32 | 143.29 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.02 | 105.50 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.67 | 93.65 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.44 | 68.43 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 70.63 | 55.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 76.96 | 40.69 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.04 | 32.53 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.21 | 36.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 141.81 | 51.42 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.43 | 70.84 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.00 | 88.62 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.21 | 121.77 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 110.84 | 75.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 70.63 | 32.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.43 | 143.29 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 122.92 | 169.46 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 170.44 | 124.86 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 142.42 | 110.84 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 106.08 | 81.06 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 84.74 | 65.47 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 92.17 | 48.26 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 114.86 | 38.65 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.41 | 43.61 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 169.79 | 61.00 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 174.26 | 84.01 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 151.12 | 104.97 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 121.55 | 144.11 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 132.88 | 89.58 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 84.74 | 38.65 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 174.26 | 169.46 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.49 | 142.27 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.35 | 104.28 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.97 | 92.25 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.93 | 66.74 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 71.19 | 53.88 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 77.52 | 39.68 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.30 | 31.99 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.44 | 36.14 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.13 | 50.55 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.86 | 69.63 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.34 | 87.44 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.44 | 120.58 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 111.19 | 74.52 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 71.19 | 31.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.86 | 142.27 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 102.49 | 142.27 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 142.35 | 104.28 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 118.97 | 92.25 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 88.93 | 66.74 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 71.19 | 53.88 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 77.52 | 39.68 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.30 | 31.99 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.44 | 36.14 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.13 | 50.55 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 145.86 | 69.63 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 126.34 | 87.44 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 101.44 | 120.58 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 111.19 | 74.52 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 71.19 | 31.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 145.86 | 142.27 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 123.12 | 168.24 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 170.84 | 123.41 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 142.79 | 109.17 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 106.67 | 79.06 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 85.42 | 63.82 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 92.85 | 47.07 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.17 | 38.01 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.68 | 42.93 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 170.16 | 59.97 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 174.78 | 82.58 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 151.53 | 103.56 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 121.83 | 142.71 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 133.30 | 88.26 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 85.42 | 38.01 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 174.78 | 168.24 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 103.37 | 137.03 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 143.68 | 98.63 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 120.23 | 85.84 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.48 | 59.98 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.89 | 48.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.17 | 35.70 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.98 | 29.63 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 124.01 | 33.65 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.90 | 47.12 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 146.95 | 65.25 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 127.51 | 82.50 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 102.41 | 115.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 112.32 | 69.83 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.89 | 29.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 146.95 | 137.03 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 103.37 | 137.03 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 143.68 | 98.63 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 120.23 | 85.84 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.48 | 59.98 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.89 | 48.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.17 | 35.70 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.98 | 29.63 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 124.01 | 33.65 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.90 | 47.12 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 146.95 | 65.25 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 127.51 | 82.50 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 102.41 | 115.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 112.32 | 69.83 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.89 | 29.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 146.95 | 137.03 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 124.19 | 161.98 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 172.45 | 116.69 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 144.32 | 101.57 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 108.56 | 71.04 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 87.47 | 57.40 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 94.83 | 42.37 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.99 | 35.23 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 148.37 | 39.99 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.09 | 55.92 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 176.09 | 77.40 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 152.94 | 97.71 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 123.00 | 136.30 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 134.67 | 82.70 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 87.47 | 35.23 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 176.09 | 161.98 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273977E+09 | 0.396247E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.342427E+09 | 0.265658E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317471E+09 | 0.260127E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226807E+09 | 0.187316E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186110E+09 | 0.156991E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198020E+09 | 0.107992E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256950E+09 | 87238956.96 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329573E+09 | 99373844.50 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366594E+09 | 0.137181E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386058E+09 | 0.201261E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323997E+09 | 0.243244E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270242E+09 | 0.339086E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347823E+10 | 0.248172E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186110E+09 | 87238956.96 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386058E+09 | 0.396247E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273977E+09 | 0.396247E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.342427E+09 | 0.265658E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317471E+09 | 0.260127E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226807E+09 | 0.187316E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186110E+09 | 0.156991E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198020E+09 | 0.107992E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256950E+09 | 87238956.96 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329573E+09 | 99373844.50 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366594E+09 | 0.137181E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386058E+09 | 0.201261E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323997E+09 | 0.243244E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270242E+09 | 0.339086E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347823E+10 | 0.248172E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186110E+09 | 87238956.96 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386058E+09 | 0.396247E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273977E+09 | 0.396247E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.342427E+09 | 0.265658E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317471E+09 | 0.260127E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226807E+09 | 0.187316E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186110E+09 | 0.156991E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198020E+09 | 0.107992E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256950E+09 | 87238956.96 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329573E+09 | 99373844.50 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366594E+09 | 0.137181E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386058E+09 | 0.201261E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323997E+09 | 0.243244E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270242E+09 | 0.339086E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347823E+10 | 0.248172E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186110E+09 | 87238956.96 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386058E+09 | 0.396247E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273977E+09 | 0.396247E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.342427E+09 | 0.265658E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317471E+09 | 0.260127E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226807E+09 | 0.187316E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186110E+09 | 0.156991E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198020E+09 | 0.107992E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256950E+09 | 87238956.96 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329573E+09 | 99373844.50 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366594E+09 | 0.137181E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386058E+09 | 0.201261E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323997E+09 | 0.243244E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270242E+09 | 0.339086E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347823E+10 | 0.248172E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186110E+09 | 87238956.96 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386058E+09 | 0.396247E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.330814E+09 | 0.471407E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.413084E+09 | 0.316303E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.382969E+09 | 0.309735E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.273481E+09 | 0.223288E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.224448E+09 | 0.187151E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.238399E+09 | 0.128922E+09 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.308884E+09 | 0.104371E+09 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.396343E+09 | 0.118820E+09 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.441218E+09 | 0.163807E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.465043E+09 | 0.240156E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.390623E+09 | 0.289872E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.326190E+09 | 0.403720E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.419149E+10 | 0.295755E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.224448E+09 | 0.104371E+09 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.465043E+09 | 0.471407E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.330814E+09 | 0.471407E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.413084E+09 | 0.316303E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.382969E+09 | 0.309735E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.273481E+09 | 0.223288E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.224448E+09 | 0.187151E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.238399E+09 | 0.128922E+09 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.308884E+09 | 0.104371E+09 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.396343E+09 | 0.118820E+09 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.441218E+09 | 0.163807E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.465043E+09 | 0.240156E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.390623E+09 | 0.289872E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.326190E+09 | 0.403720E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.419149E+10 | 0.295755E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.224448E+09 | 0.104371E+09 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.465043E+09 | 0.471407E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.270674E+09 | 0.409939E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.338252E+09 | 0.278287E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.313452E+09 | 0.274863E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.222802E+09 | 0.200849E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.183001E+09 | 0.165969E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196366E+09 | 0.111151E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256668E+09 | 88050062.51 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328983E+09 | 0.100660E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.364948E+09 | 0.141096E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.382943E+09 | 0.209438E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.320433E+09 | 0.254094E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.266888E+09 | 0.352307E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.344541E+10 | 0.258670E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.183001E+09 | 88050062.51 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.382943E+09 | 0.409939E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.270674E+09 | 0.409939E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.338252E+09 | 0.278287E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.313452E+09 | 0.274863E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.222802E+09 | 0.200849E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.183001E+09 | 0.165969E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196366E+09 | 0.111151E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256668E+09 | 88050062.51 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328983E+09 | 0.100660E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.364948E+09 | 0.141096E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.382943E+09 | 0.209438E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.320433E+09 | 0.254094E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.266888E+09 | 0.352307E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.344541E+10 | 0.258670E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.183001E+09 | 88050062.51 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.382943E+09 | 0.409939E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.326860E+09 | 0.487599E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.408096E+09 | 0.331209E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.378150E+09 | 0.327143E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.268679E+09 | 0.239284E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.220713E+09 | 0.197731E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.236411E+09 | 0.132629E+09 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.308543E+09 | 0.105309E+09 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.395648E+09 | 0.120317E+09 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.439279E+09 | 0.168392E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.461359E+09 | 0.249755E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.386386E+09 | 0.302633E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.322178E+09 | 0.419323E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.415230E+10 | 0.308132E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.220713E+09 | 0.105309E+09 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.461359E+09 | 0.487599E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.271727E+09 | 0.396623E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.340039E+09 | 0.267118E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.314875E+09 | 0.263422E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.224972E+09 | 0.190620E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.184560E+09 | 0.159581E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196413E+09 | 0.112077E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255411E+09 | 92199641.19 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328268E+09 | 0.103875E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.365193E+09 | 0.140312E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.385223E+09 | 0.201518E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.322728E+09 | 0.242396E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.268210E+09 | 0.339699E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.345762E+10 | 0.250944E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.184560E+09 | 92199641.19 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.385223E+09 | 0.396623E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.271727E+09 | 0.396623E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.340039E+09 | 0.267118E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.314875E+09 | 0.263422E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.224972E+09 | 0.190620E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.184560E+09 | 0.159581E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196413E+09 | 0.112077E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255411E+09 | 92199641.19 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328268E+09 | 0.103875E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.365193E+09 | 0.140312E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.385223E+09 | 0.201518E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.322728E+09 | 0.242396E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.268210E+09 | 0.339699E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.345762E+10 | 0.250944E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.184560E+09 | 92199641.19 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.385223E+09 | 0.396623E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.326371E+09 | 0.469141E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.408030E+09 | 0.316175E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.377823E+09 | 0.311808E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.269824E+09 | 0.225854E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.221399E+09 | 0.189032E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.235213E+09 | 0.132912E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.305421E+09 | 0.109540E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.392677E+09 | 0.123363E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.437204E+09 | 0.166461E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.461575E+09 | 0.238970E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.387037E+09 | 0.287122E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.322038E+09 | 0.402093E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.414461E+10 | 0.297247E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.221399E+09 | 0.109540E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.461575E+09 | 0.469141E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.272249E+09 | 0.392652E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.340879E+09 | 0.263344E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.315589E+09 | 0.259616E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226081E+09 | 0.186529E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.185575E+09 | 0.156427E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196862E+09 | 0.111069E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255560E+09 | 92004242.98 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328458E+09 | 0.103434E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.365669E+09 | 0.138780E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386359E+09 | 0.197840E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323739E+09 | 0.238110E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.268855E+09 | 0.335496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.346588E+10 | 0.247530E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.185575E+09 | 92004242.98 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386359E+09 | 0.392652E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.272249E+09 | 0.392652E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.340879E+09 | 0.263344E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.315589E+09 | 0.259616E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226081E+09 | 0.186529E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.185575E+09 | 0.156427E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.196862E+09 | 0.111069E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255560E+09 | 92004242.98 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328458E+09 | 0.103434E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.365669E+09 | 0.138780E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.386359E+09 | 0.197840E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.323739E+09 | 0.238110E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.268855E+09 | 0.335496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.346588E+10 | 0.247530E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.185575E+09 | 92004242.98 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.386359E+09 | 0.392652E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.327007E+09 | 0.464408E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.409044E+09 | 0.311689E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.378689E+09 | 0.307282E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.271157E+09 | 0.220994E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.222623E+09 | 0.185291E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.235754E+09 | 0.131717E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.305601E+09 | 0.109308E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.392907E+09 | 0.122839E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.437776E+09 | 0.164642E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.462937E+09 | 0.234605E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.388255E+09 | 0.282030E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.322823E+09 | 0.397094E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.415457E+10 | 0.293190E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.222623E+09 | 0.109308E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.462937E+09 | 0.464408E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.272663E+09 | 0.390542E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.341509E+09 | 0.261266E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.316125E+09 | 0.257513E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226914E+09 | 0.184063E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186467E+09 | 0.154276E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.197409E+09 | 0.109921E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255888E+09 | 91149400.03 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328790E+09 | 0.102473E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366154E+09 | 0.137451E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.387256E+09 | 0.195516E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.324461E+09 | 0.235736E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.269376E+09 | 0.333118E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347301E+10 | 0.245302E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186467E+09 | 91149400.03 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.387256E+09 | 0.390542E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.272663E+09 | 0.390542E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.341509E+09 | 0.261266E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.316125E+09 | 0.257513E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.226914E+09 | 0.184063E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.186467E+09 | 0.154276E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.197409E+09 | 0.109921E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.255888E+09 | 91149400.03 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.328790E+09 | 0.102473E+09 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.366154E+09 | 0.137451E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.387256E+09 | 0.195516E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.324461E+09 | 0.235736E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.269376E+09 | 0.333118E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.347301E+10 | 0.245302E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.186467E+09 | 91149400.03 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.387256E+09 | 0.390542E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.327509E+09 | 0.461891E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.409807E+09 | 0.309220E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.379339E+09 | 0.304781E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.272157E+09 | 0.218065E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.223696E+09 | 0.182743E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.236410E+09 | 0.130359E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.305996E+09 | 0.108298E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.393308E+09 | 0.121704E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.438358E+09 | 0.163069E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.464012E+09 | 0.231854E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.389124E+09 | 0.279213E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.323458E+09 | 0.394268E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.416317E+10 | 0.290547E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.223696E+09 | 0.108298E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.464012E+09 | 0.461891E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.275335E+09 | 0.381375E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344696E+09 | 0.254091E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318731E+09 | 0.250250E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229226E+09 | 0.177991E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188724E+09 | 0.148847E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198561E+09 | 0.106568E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256146E+09 | 88297918.85 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329341E+09 | 99439761.53 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367487E+09 | 0.134112E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389843E+09 | 0.190460E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327284E+09 | 0.229334E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.272257E+09 | 0.324496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349763E+10 | 0.238526E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188724E+09 | 88297918.85 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389843E+09 | 0.381375E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.275335E+09 | 0.381375E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344696E+09 | 0.254091E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318731E+09 | 0.250250E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229226E+09 | 0.177991E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188724E+09 | 0.148847E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198561E+09 | 0.106568E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256146E+09 | 88297918.85 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329341E+09 | 99439761.53 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367487E+09 | 0.134112E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389843E+09 | 0.190460E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327284E+09 | 0.229334E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.272257E+09 | 0.324496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349763E+10 | 0.238526E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188724E+09 | 88297918.85 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389843E+09 | 0.381375E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.275335E+09 | 0.381375E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344696E+09 | 0.254091E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318731E+09 | 0.250250E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229226E+09 | 0.177991E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188724E+09 | 0.148847E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198561E+09 | 0.106568E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256146E+09 | 88297918.85 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329341E+09 | 99439761.53 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367487E+09 | 0.134112E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389843E+09 | 0.190460E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327284E+09 | 0.229334E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.272257E+09 | 0.324496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349763E+10 | 0.238526E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188724E+09 | 88297918.85 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389843E+09 | 0.381375E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.275335E+09 | 0.381375E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344696E+09 | 0.254091E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318731E+09 | 0.250250E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229226E+09 | 0.177991E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188724E+09 | 0.148847E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198561E+09 | 0.106568E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256146E+09 | 88297918.85 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329341E+09 | 99439761.53 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367487E+09 | 0.134112E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389843E+09 | 0.190460E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327284E+09 | 0.229334E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.272257E+09 | 0.324496E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349763E+10 | 0.238526E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188724E+09 | 88297918.85 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389843E+09 | 0.381375E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.330682E+09 | 0.451148E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.413586E+09 | 0.300811E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.382448E+09 | 0.296269E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.274921E+09 | 0.210921E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.226410E+09 | 0.176372E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.237806E+09 | 0.126422E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.306336E+09 | 0.104941E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.393984E+09 | 0.118134E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.439941E+09 | 0.159148E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.467068E+09 | 0.225915E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.392467E+09 | 0.271703E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.326878E+09 | 0.384149E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.419253E+10 | 0.282593E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.226410E+09 | 0.104941E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.467068E+09 | 0.451148E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.330682E+09 | 0.451148E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.413586E+09 | 0.300811E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.382448E+09 | 0.296269E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.274921E+09 | 0.210921E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.226410E+09 | 0.176372E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.237806E+09 | 0.126422E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.306336E+09 | 0.104941E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.393984E+09 | 0.118134E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.439941E+09 | 0.159148E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.467068E+09 | 0.225915E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.392467E+09 | 0.271703E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.326878E+09 | 0.384149E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.419253E+10 | 0.282593E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.226410E+09 | 0.104941E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.467068E+09 | 0.451148E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273958E+09 | 0.384298E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.343370E+09 | 0.255821E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317620E+09 | 0.251684E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.228826E+09 | 0.178535E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188644E+09 | 0.149119E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198959E+09 | 0.106276E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256912E+09 | 87631933.77 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329740E+09 | 98867398.33 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367254E+09 | 0.134014E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389082E+09 | 0.190780E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.326304E+09 | 0.230523E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270937E+09 | 0.326797E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349161E+10 | 0.239435E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188644E+09 | 87631933.77 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389082E+09 | 0.384298E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.273958E+09 | 0.384298E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.343370E+09 | 0.255821E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317620E+09 | 0.251684E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.228826E+09 | 0.178535E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.188644E+09 | 0.149119E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.198959E+09 | 0.106276E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.256912E+09 | 87631933.77 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329740E+09 | 98867398.33 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367254E+09 | 0.134014E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389082E+09 | 0.190780E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.326304E+09 | 0.230523E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.270937E+09 | 0.326797E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349161E+10 | 0.239435E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.188644E+09 | 87631933.77 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389082E+09 | 0.384298E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.329093E+09 | 0.454484E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.412068E+09 | 0.302775E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.381177E+09 | 0.297877E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.274477E+09 | 0.211505E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.226339E+09 | 0.176637E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.238296E+09 | 0.126043E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.307255E+09 | 0.104134E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.394479E+09 | 0.117429E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.439703E+09 | 0.158989E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.466220E+09 | 0.226234E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.391356E+09 | 0.273033E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.325362E+09 | 0.386774E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.418583E+10 | 0.283591E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.226339E+09 | 0.104134E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.466220E+09 | 0.454484E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.274061E+09 | 0.383796E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.343580E+09 | 0.255222E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317843E+09 | 0.250836E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229235E+09 | 0.177366E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.189167E+09 | 0.148045E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.199473E+09 | 0.105467E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.257228E+09 | 87124094.53 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330015E+09 | 98338510.40 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367578E+09 | 0.133274E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389521E+09 | 0.189744E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.326581E+09 | 0.229712E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.271093E+09 | 0.326144E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349537E+10 | 0.238507E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.189167E+09 | 87124094.53 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389521E+09 | 0.383796E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.274061E+09 | 0.383796E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.343580E+09 | 0.255222E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.317843E+09 | 0.250836E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.229235E+09 | 0.177366E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.189167E+09 | 0.148045E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.199473E+09 | 0.105467E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.257228E+09 | 87124094.53 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330015E+09 | 98338510.40 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.367578E+09 | 0.133274E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.389521E+09 | 0.189744E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.326581E+09 | 0.229712E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.271093E+09 | 0.326144E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.349537E+10 | 0.238507E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.189167E+09 | 87124094.53 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.389521E+09 | 0.383796E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.329218E+09 | 0.453885E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.412321E+09 | 0.302063E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.381450E+09 | 0.296869E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.274970E+09 | 0.210117E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.226969E+09 | 0.175364E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.238915E+09 | 0.125086E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.307635E+09 | 0.103532E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.394810E+09 | 0.116801E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.440094E+09 | 0.158110E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.466746E+09 | 0.225005E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.391692E+09 | 0.272070E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.325552E+09 | 0.385997E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.419037E+10 | 0.282490E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.226969E+09 | 0.103532E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.466746E+09 | 0.453885E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.274515E+09 | 0.381062E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344379E+09 | 0.252267E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318658E+09 | 0.247079E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.230501E+09 | 0.173001E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.190682E+09 | 0.144300E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.200925E+09 | 0.102854E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.257929E+09 | 85671055.50 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330620E+09 | 96808191.35 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368389E+09 | 0.131017E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.390672E+09 | 0.186509E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327465E+09 | 0.226632E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.271707E+09 | 0.322974E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.350644E+10 | 0.235017E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.190682E+09 | 85671055.50 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.390672E+09 | 0.381062E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.274515E+09 | 0.381062E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.344379E+09 | 0.252267E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.318658E+09 | 0.247079E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.230501E+09 | 0.173001E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.190682E+09 | 0.144300E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.200925E+09 | 0.102854E+09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.257929E+09 | 85671055.50 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330620E+09 | 96808191.35 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368389E+09 | 0.131017E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.390672E+09 | 0.186509E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.327465E+09 | 0.226632E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.271707E+09 | 0.322974E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.350644E+10 | 0.235017E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.190682E+09 | 85671055.50 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.390672E+09 | 0.381062E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.329771E+09 | 0.450626E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.413287E+09 | 0.298552E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.382443E+09 | 0.292405E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.276499E+09 | 0.204934E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.228793E+09 | 0.170928E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.240658E+09 | 0.121994E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.308480E+09 | 0.101813E+09 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.395541E+09 | 0.114992E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.441067E+09 | 0.155438E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.468127E+09 | 0.221171E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.392763E+09 | 0.268420E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.326298E+09 | 0.382228E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.420373E+10 | 0.278350E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.228793E+09 | 0.101813E+09 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.468127E+09 | 0.450626E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.276870E+09 | 0.367013E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.347596E+09 | 0.238601E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.322019E+09 | 0.229919E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.234537E+09 | 0.155457E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.195231E+09 | 0.129757E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205204E+09 | 92544955.26 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259762E+09 | 79362671.69 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.332154E+09 | 90126828.52 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370391E+09 | 0.122134E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.393594E+09 | 0.174766E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.330496E+09 | 0.213832E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.274287E+09 | 0.308556E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.354214E+10 | 0.220207E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.195231E+09 | 79362671.69 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.393594E+09 | 0.367013E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.276870E+09 | 0.367013E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.347596E+09 | 0.238601E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.322019E+09 | 0.229919E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.234537E+09 | 0.155457E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.195231E+09 | 0.129757E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205204E+09 | 92544955.26 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259762E+09 | 79362671.69 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.332154E+09 | 90126828.52 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370391E+09 | 0.122134E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.393594E+09 | 0.174766E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.330496E+09 | 0.213832E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.274287E+09 | 0.308556E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.354214E+10 | 0.220207E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.195231E+09 | 79362671.69 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.393594E+09 | 0.367013E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.332641E+09 | 0.433849E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.417183E+09 | 0.282307E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.386544E+09 | 0.272033E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.281385E+09 | 0.184140E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.234285E+09 | 0.153727E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.245790E+09 | 0.109817E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.310680E+09 | 94364963.91 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.397389E+09 | 0.107102E+09 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.443478E+09 | 0.144949E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.471644E+09 | 0.207298E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.396428E+09 | 0.253262E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.329431E+09 | 0.365077E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.424688E+10 | 0.260793E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.234285E+09 | 94364963.91 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.471644E+09 | 0.433849E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 656.19 | 943.77 | 756.02 | 539.89 | 216.13 | 0.00 | 0.00 |
February | 907.69 | 700.74 | 963.12 | 692.72 | 270.40 | 0.00 | 0.00 |
March | 760.09 | 619.76 | 861.25 | 483.79 | 377.45 | 0.00 | 0.00 |
April | 561.03 | 461.36 | 692.06 | 331.04 | 361.02 | 0.00 | 0.00 |
May | 445.54 | 374.20 | 614.74 | 204.11 | 410.63 | 0.00 | 0.00 |
June | 489.54 | 266.13 | 610.79 | 178.06 | 432.73 | 0.00 | 0.00 |
July | 614.38 | 208.22 | 658.47 | 243.15 | 415.32 | 0.00 | 0.00 |
August | 788.15 | 237.13 | 782.67 | 394.59 | 388.08 | 0.00 | 0.00 |
September | 906.18 | 338.09 | 868.46 | 532.26 | 336.20 | 0.00 | 0.00 |
October | 923.80 | 479.90 | 907.84 | 627.84 | 280.00 | 0.00 | 0.00 |
November | 801.40 | 599.04 | 827.26 | 599.19 | 228.08 | 0.00 | 0.00 |
December | 647.16 | 807.86 | 718.90 | 519.04 | 199.86 | 0.00 | 0.00 |
Annual Sum or Average | 707.00 | 502.35 | 770.47 | 443.83 | 326.64 | 0.00 | 0.00 |
Minimum of Months | 445.54 | 208.22 | 610.79 | 178.06 | 199.86 | 0.00 | 0.00 |
Maximum of Months | 923.80 | 943.77 | 963.12 | 692.72 | 432.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 324.15 | 488.15 | 378.01 | 269.95 | 108.06 | 0.00 | 0.00 |
February | 448.33 | 366.97 | 481.56 | 346.36 | 135.20 | 0.00 | 0.00 |
March | 375.24 | 327.38 | 430.62 | 241.90 | 188.73 | 0.00 | 0.00 |
April | 275.57 | 247.29 | 346.03 | 165.52 | 180.51 | 0.00 | 0.00 |
May | 219.05 | 197.76 | 307.37 | 102.05 | 205.32 | 0.00 | 0.00 |
June | 242.72 | 136.93 | 305.39 | 89.03 | 216.37 | 0.00 | 0.00 |
July | 306.85 | 105.07 | 329.24 | 121.58 | 207.66 | 0.00 | 0.00 |
August | 393.37 | 120.09 | 391.34 | 197.29 | 194.04 | 0.00 | 0.00 |
September | 451.07 | 173.84 | 434.23 | 266.13 | 168.10 | 0.00 | 0.00 |
October | 458.20 | 249.64 | 453.92 | 313.92 | 140.00 | 0.00 | 0.00 |
November | 396.32 | 312.82 | 413.63 | 299.59 | 114.04 | 0.00 | 0.00 |
December | 319.58 | 419.63 | 359.45 | 259.52 | 99.93 | 0.00 | 0.00 |
Annual Sum or Average | 350.17 | 261.76 | 385.23 | 221.91 | 163.32 | 0.00 | 0.00 |
Minimum of Months | 219.05 | 105.07 | 305.39 | 89.03 | 99.93 | 0.00 | 0.00 |
Maximum of Months | 458.20 | 488.15 | 481.56 | 346.36 | 216.37 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 324.75 | 471.32 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 449.78 | 351.53 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 376.18 | 313.12 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 277.69 | 234.22 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 220.47 | 189.74 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 242.30 | 137.76 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 304.75 | 109.74 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 391.73 | 123.62 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 450.46 | 172.49 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 459.98 | 239.70 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 398.34 | 297.81 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 320.51 | 403.78 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 350.71 | 253.40 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 220.47 | 109.74 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 459.98 | 471.32 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 325.38 | 466.59 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 450.89 | 346.55 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 377.04 | 308.58 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 279.06 | 229.19 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 221.69 | 185.99 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 242.85 | 136.52 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 304.93 | 109.51 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 391.96 | 123.10 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 451.05 | 170.60 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 461.34 | 235.32 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 399.59 | 292.53 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 321.29 | 398.78 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 351.54 | 249.95 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 221.69 | 109.51 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 461.34 | 466.59 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 325.88 | 464.07 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 451.73 | 343.81 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 377.68 | 306.08 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 280.09 | 226.15 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 222.76 | 183.43 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 243.53 | 135.11 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 305.32 | 108.50 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 392.36 | 121.96 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 451.65 | 168.97 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 462.41 | 232.56 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 400.48 | 289.62 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 321.91 | 395.95 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 352.27 | 247.70 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 222.76 | 108.50 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 462.41 | 464.07 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 658.12 | 906.43 | 754.47 | 538.78 | 215.68 | 0.00 | 0.00 |
February | 911.85 | 668.81 | 961.15 | 691.30 | 269.85 | 0.00 | 0.00 |
March | 761.58 | 594.96 | 859.48 | 482.80 | 376.68 | 0.00 | 0.00 |
April | 565.87 | 437.42 | 690.64 | 330.36 | 360.28 | 0.00 | 0.00 |
May | 450.91 | 353.99 | 613.48 | 203.69 | 409.79 | 0.00 | 0.00 |
June | 489.91 | 262.00 | 609.53 | 177.69 | 431.84 | 0.00 | 0.00 |
July | 611.28 | 210.23 | 657.12 | 242.65 | 414.47 | 0.00 | 0.00 |
August | 786.04 | 236.72 | 781.07 | 393.78 | 387.29 | 0.00 | 0.00 |
September | 906.57 | 329.76 | 866.68 | 531.17 | 335.51 | 0.00 | 0.00 |
October | 930.97 | 453.13 | 905.98 | 626.55 | 279.42 | 0.00 | 0.00 |
November | 807.90 | 563.56 | 825.57 | 597.96 | 227.61 | 0.00 | 0.00 |
December | 650.68 | 771.46 | 717.42 | 517.97 | 199.45 | 0.00 | 0.00 |
Annual Sum or Average | 709.52 | 481.76 | 768.89 | 442.92 | 325.97 | 0.00 | 0.00 |
Minimum of Months | 450.91 | 210.23 | 609.53 | 177.69 | 199.45 | 0.00 | 0.00 |
Maximum of Months | 930.97 | 906.43 | 961.15 | 691.30 | 431.84 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 327.44 | 456.65 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 454.20 | 336.65 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 379.49 | 299.15 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 282.46 | 219.36 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 225.37 | 177.30 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 245.45 | 130.63 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 306.56 | 104.32 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 393.50 | 117.67 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 453.01 | 164.74 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 464.60 | 226.92 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 402.76 | 283.21 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 323.79 | 388.43 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 354.17 | 241.77 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 225.37 | 104.32 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 464.60 | 456.65 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 327.56 | 456.05 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 454.48 | 335.86 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 379.75 | 298.14 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 282.96 | 217.92 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 225.99 | 176.02 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 246.09 | 129.64 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 306.93 | 103.71 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 393.83 | 117.04 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 453.41 | 163.83 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 465.12 | 225.69 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 403.11 | 282.21 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 323.98 | 387.65 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 354.55 | 240.84 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 225.99 | 103.71 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 465.12 | 456.05 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 328.11 | 452.79 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 455.54 | 331.96 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 380.73 | 293.67 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 284.53 | 212.55 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 227.81 | 171.57 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 247.88 | 126.43 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 307.77 | 101.98 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 394.56 | 115.22 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 454.42 | 161.06 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 466.50 | 221.84 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 404.20 | 278.43 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 324.71 | 383.88 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 355.68 | 237.31 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 227.81 | 101.98 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 466.50 | 452.79 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 330.94 | 436.03 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 459.81 | 313.95 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 384.77 | 273.25 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 289.53 | 190.99 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 233.25 | 154.29 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 253.16 | 113.78 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 309.96 | 94.49 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 396.39 | 107.29 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 456.89 | 150.16 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 469.99 | 207.90 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 407.96 | 262.70 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 327.81 | 366.71 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 359.31 | 222.35 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 233.25 | 94.49 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 469.99 | 436.03 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.175753E+10 | 0.252780E+10 | 0.202492E+10 | 0.144605E+10 | 0.578876E+09 | 0.00 | 0.00 |
February | 0.219588E+10 | 0.169524E+10 | 0.232999E+10 | 0.167583E+10 | 0.654159E+09 | 0.00 | 0.00 |
March | 0.203582E+10 | 0.165998E+10 | 0.230677E+10 | 0.129580E+10 | 0.101097E+10 | 0.00 | 0.00 |
April | 0.145419E+10 | 0.119584E+10 | 0.179381E+10 | 0.858059E+09 | 0.935756E+09 | 0.00 | 0.00 |
May | 0.119333E+10 | 0.100226E+10 | 0.164651E+10 | 0.546682E+09 | 0.109983E+10 | 0.00 | 0.00 |
June | 0.126888E+10 | 0.689812E+09 | 0.158316E+10 | 0.461522E+09 | 0.112164E+10 | 0.00 | 0.00 |
July | 0.164557E+10 | 0.557696E+09 | 0.176365E+10 | 0.651256E+09 | 0.111240E+10 | 0.00 | 0.00 |
August | 0.211098E+10 | 0.635135E+09 | 0.209631E+10 | 0.105687E+10 | 0.103944E+10 | 0.00 | 0.00 |
September | 0.234881E+10 | 0.876338E+09 | 0.225105E+10 | 0.137963E+10 | 0.871421E+09 | 0.00 | 0.00 |
October | 0.247432E+10 | 0.128536E+10 | 0.243156E+10 | 0.168161E+10 | 0.749950E+09 | 0.00 | 0.00 |
November | 0.207723E+10 | 0.155272E+10 | 0.214427E+10 | 0.155309E+10 | 0.591174E+09 | 0.00 | 0.00 |
December | 0.173335E+10 | 0.216378E+10 | 0.192550E+10 | 0.139020E+10 | 0.535298E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.222959E+11 | 0.158420E+11 | 0.242975E+11 | 0.139966E+11 | 0.103009E+11 | 0.00 | 0.00 |
Minimum of Months | 0.119333E+10 | 0.557696E+09 | 0.158316E+10 | 0.461522E+09 | 0.535298E+09 | 0.00 | 0.00 |
Maximum of Months | 0.247432E+10 | 0.252780E+10 | 0.243156E+10 | 0.168161E+10 | 0.112164E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.868203E+09 | 0.130747E+10 | 0.101246E+10 | 0.723023E+09 | 0.289438E+09 | 0.00 | 0.00 |
February | 0.108460E+10 | 0.887780E+09 | 0.116499E+10 | 0.837915E+09 | 0.327080E+09 | 0.00 | 0.00 |
March | 0.100505E+10 | 0.876865E+09 | 0.115338E+10 | 0.647898E+09 | 0.505485E+09 | 0.00 | 0.00 |
April | 0.714282E+09 | 0.640980E+09 | 0.896907E+09 | 0.429029E+09 | 0.467878E+09 | 0.00 | 0.00 |
May | 0.586715E+09 | 0.529668E+09 | 0.823257E+09 | 0.273341E+09 | 0.549916E+09 | 0.00 | 0.00 |
June | 0.629143E+09 | 0.354931E+09 | 0.791580E+09 | 0.230761E+09 | 0.560820E+09 | 0.00 | 0.00 |
July | 0.821879E+09 | 0.281409E+09 | 0.881826E+09 | 0.325628E+09 | 0.556198E+09 | 0.00 | 0.00 |
August | 0.105361E+10 | 0.321637E+09 | 0.104816E+10 | 0.528435E+09 | 0.519722E+09 | 0.00 | 0.00 |
September | 0.116917E+10 | 0.450583E+09 | 0.112552E+10 | 0.689814E+09 | 0.435711E+09 | 0.00 | 0.00 |
October | 0.122724E+10 | 0.668629E+09 | 0.121578E+10 | 0.840807E+09 | 0.374975E+09 | 0.00 | 0.00 |
November | 0.102725E+10 | 0.810821E+09 | 0.107213E+10 | 0.776547E+09 | 0.295587E+09 | 0.00 | 0.00 |
December | 0.855951E+09 | 0.112393E+10 | 0.962748E+09 | 0.695099E+09 | 0.267649E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.110431E+11 | 0.825471E+10 | 0.121488E+11 | 0.699830E+10 | 0.515046E+10 | 0.00 | 0.00 |
Minimum of Months | 0.586715E+09 | 0.281409E+09 | 0.791580E+09 | 0.230761E+09 | 0.267649E+09 | 0.00 | 0.00 |
Maximum of Months | 0.122724E+10 | 0.130747E+10 | 0.121578E+10 | 0.840807E+09 | 0.560820E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.869821E+09 | 0.126238E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.108811E+10 | 0.850411E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.100757E+10 | 0.838651E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.719768E+09 | 0.607093E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.590517E+09 | 0.508192E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.628038E+09 | 0.357066E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.816242E+09 | 0.293939E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.104921E+10 | 0.331113E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.116759E+10 | 0.447085E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.123202E+10 | 0.642005E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.103249E+10 | 0.771914E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.858458E+09 | 0.108149E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.110598E+11 | 0.799134E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.590517E+09 | 0.293939E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.123202E+10 | 0.126238E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.871504E+09 | 0.124971E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.109080E+10 | 0.838377E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.100987E+10 | 0.826513E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.723319E+09 | 0.594053E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.593772E+09 | 0.498143E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.629478E+09 | 0.353856E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.816721E+09 | 0.293316E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.104982E+10 | 0.329706E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.116911E+10 | 0.442200E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.123565E+10 | 0.630284E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.103573E+10 | 0.758250E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.860531E+09 | 0.106808E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.110863E+11 | 0.788249E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.593772E+09 | 0.293316E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.123565E+10 | 0.124971E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.872833E+09 | 0.124297E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.109282E+10 | 0.831749E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.101159E+10 | 0.819806E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.725985E+09 | 0.586191E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.596631E+09 | 0.491295E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.631229E+09 | 0.350200E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.817773E+09 | 0.290597E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105089E+10 | 0.326650E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117067E+10 | 0.437971E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.123852E+10 | 0.622886E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.103805E+10 | 0.750684E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.862207E+09 | 0.106050E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.111092E+11 | 0.781150E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.596631E+09 | 0.290597E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.123852E+10 | 0.124297E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.176270E+10 | 0.242779E+10 | 0.202076E+10 | 0.144308E+10 | 0.577688E+09 | 0.00 | 0.00 |
February | 0.220595E+10 | 0.161798E+10 | 0.232520E+10 | 0.167239E+10 | 0.652816E+09 | 0.00 | 0.00 |
March | 0.203981E+10 | 0.159353E+10 | 0.230203E+10 | 0.129314E+10 | 0.100889E+10 | 0.00 | 0.00 |
April | 0.146674E+10 | 0.113381E+10 | 0.179013E+10 | 0.856297E+09 | 0.933834E+09 | 0.00 | 0.00 |
May | 0.120771E+10 | 0.948126E+09 | 0.164313E+10 | 0.545560E+09 | 0.109757E+10 | 0.00 | 0.00 |
June | 0.126985E+10 | 0.679114E+09 | 0.157991E+10 | 0.460574E+09 | 0.111934E+10 | 0.00 | 0.00 |
July | 0.163725E+10 | 0.563073E+09 | 0.176003E+10 | 0.649918E+09 | 0.111011E+10 | 0.00 | 0.00 |
August | 0.210533E+10 | 0.634026E+09 | 0.209201E+10 | 0.105470E+10 | 0.103731E+10 | 0.00 | 0.00 |
September | 0.234983E+10 | 0.854744E+09 | 0.224643E+10 | 0.137680E+10 | 0.869632E+09 | 0.00 | 0.00 |
October | 0.249351E+10 | 0.121367E+10 | 0.242657E+10 | 0.167816E+10 | 0.748410E+09 | 0.00 | 0.00 |
November | 0.209407E+10 | 0.146074E+10 | 0.213986E+10 | 0.154990E+10 | 0.589960E+09 | 0.00 | 0.00 |
December | 0.174278E+10 | 0.206628E+10 | 0.192154E+10 | 0.138734E+10 | 0.534199E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.223755E+11 | 0.151929E+11 | 0.242476E+11 | 0.139679E+11 | 0.102798E+11 | 0.00 | 0.00 |
Minimum of Months | 0.120771E+10 | 0.563073E+09 | 0.157991E+10 | 0.460574E+09 | 0.534199E+09 | 0.00 | 0.00 |
Maximum of Months | 0.249351E+10 | 0.242779E+10 | 0.242657E+10 | 0.167816E+10 | 0.111934E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.877009E+09 | 0.122308E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.109881E+10 | 0.814415E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.101641E+10 | 0.801242E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.732129E+09 | 0.568575E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.603625E+09 | 0.474873E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.636214E+09 | 0.338595E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.821078E+09 | 0.279397E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105396E+10 | 0.315163E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117421E+10 | 0.427016E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.124438E+10 | 0.607793E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.104396E+10 | 0.734079E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.867235E+09 | 0.104037E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.111690E+11 | 0.762459E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.603625E+09 | 0.279397E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.124438E+10 | 0.122308E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.877339E+09 | 0.122147E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.109948E+10 | 0.812506E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.101713E+10 | 0.798538E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.733438E+09 | 0.564848E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.605301E+09 | 0.471453E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.637859E+09 | 0.336020E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.822090E+09 | 0.277780E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105484E+10 | 0.313478E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117525E+10 | 0.424656E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.124579E+10 | 0.604492E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.104485E+10 | 0.731493E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.867736E+09 | 0.103828E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.111811E+11 | 0.759502E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.605301E+09 | 0.277780E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.124579E+10 | 0.122147E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.878799E+09 | 0.121275E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.110204E+10 | 0.803084E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.101976E+10 | 0.786562E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.737501E+09 | 0.550934E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.610155E+09 | 0.459527E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.642508E+09 | 0.327701E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.824338E+09 | 0.273155E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105678E+10 | 0.308608E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117785E+10 | 0.417472E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.124947E+10 | 0.594188E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.104769E+10 | 0.721685E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.869713E+09 | 0.102818E+10 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.112166E+11 | 0.748384E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.610155E+09 | 0.273155E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.124947E+10 | 0.121275E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.886379E+09 | 0.116787E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.111237E+10 | 0.759509E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.103058E+10 | 0.731868E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.750456E+09 | 0.495052E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.624747E+09 | 0.413241E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.656198E+09 | 0.294907E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.830203E+09 | 0.253090E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.106170E+10 | 0.287355E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.118426E+10 | 0.389218E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.125883E+10 | 0.556830E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.105742E+10 | 0.680925E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.878003E+09 | 0.982188E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.113311E+11 | 0.701206E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.624747E+09 | 0.253090E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.125883E+10 | 0.116787E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -8.8 | -10.8 | -16.1 | 5.70 | -23.3 | 32.48 | 106.19 | 0.00 |
February | -2.2 | -4.9 | -9.9 | 6.21 | -16.1 | 41.31 | 158.25 | 0.00 |
March | 0.30 | -2.8 | -8.4 | 5.38 | -12.8 | 78.62 | 145.02 | 0.00 |
April | 6.67 | 2.37 | -2.9 | 4.89 | -6.2 | 82.10 | 182.32 | 0.01 |
May | 10.10 | 5.18 | 0.22 | 5.28 | -1.1 | 102.67 | 205.47 | 0.01 |
June | 16.46 | 10.04 | 4.91 | 4.56 | 5.04 | 103.05 | 264.47 | 0.02 |
July | 20.57 | 12.44 | 6.56 | 4.24 | 8.00 | 89.47 | 301.47 | 0.00 |
August | 19.17 | 11.02 | 4.61 | 4.29 | 7.18 | 78.96 | 261.05 | 0.00 |
September | 14.69 | 9.07 | 4.37 | 5.43 | 3.41 | 63.03 | 204.21 | 0.00 |
October | 8.64 | 4.13 | -1.0 | 5.38 | -4.2 | 47.64 | 162.42 | 0.00 |
November | 2.84 | -0.8 | -6.9 | 5.91 | -11.0 | 33.00 | 125.52 | 0.00 |
December | -4.1 | -6.4 | -11.1 | 5.64 | -18.2 | 26.54 | 97.81 | 0.00 |
Annual Sum or Average | 7.07 | 2.40 | -2.9 | 5.23 | -5.7 | 65.04 | 184.63 | 0.00 |
Minimum of Months | -8.8 | -10.8 | -16.1 | 4.24 | -23.3 | 26.54 | 97.81 | 0.00 |
Maximum of Months | 20.57 | 12.44 | 6.56 | 6.21 | 8.00 | 103.05 | 301.47 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.60 | 14-JAN-12:00 | 5.15 | -1.1 | 8.20 | -2.3 | 105.00 | 464.50 |
February | 18.90 | 27-FEB-14:00 | 7.20 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 15.00 | 14-MAR-13:20 | 6.65 | -2.4 | 9.30 | 1.23 | 201.67 | 711.67 |
April | 23.30 | 07-APR-13:00 | 9.64 | -4.4 | 9.30 | 4.92 | 314.50 | 110.00 |
May | 30.00 | 20-MAY-15:00 | 15.19 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 32.20 | 29-JUN-12:00 | 14.36 | 0.60 | 9.30 | 17.03 | 187.00 | 729.00 |
July | 37.20 | 17-JUL-15:00 | 17.25 | 4.40 | 4.60 | 20.22 | 119.50 | 797.00 |
August | 35.60 | 05-AUG-15:00 | 17.61 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 34.40 | 02-SEP-14:00 | 16.25 | 4.40 | 7.70 | 20.75 | 95.50 | 789.50 |
October | 25.00 | 18-OCT-13:00 | 11.37 | -1.1 | 7.70 | 7.35 | 48.00 | 913.00 |
November | 17.20 | 04-NOV-13:00 | 8.15 | -1.1 | 11.30 | 2.22 | 81.00 | 689.50 |
December | 13.90 | 10-DEC-01:00 | 5.47 | -5.0 | 13.90 | 5.74 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.60 | 5.15 | -7.8 | 4.60 | -2.3 | 0.00 | 0.00 | |
Maximum of Months | 37.20 | 17.61 | 6.70 | 13.90 | 22.47 | 314.50 | 913.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -33.9 | 10-JAN-21:00 | -34.0 | -37.8 | 3.10 | -54.3 | 0.00 | 0.00 |
February | -25.0 | 01-FEB-03:00 | -25.2 | -27.8 | 2.10 | -45.6 | 0.00 | 0.00 |
March | -23.3 | 04-MAR-23:00 | -23.8 | -28.9 | 3.60 | -44.5 | 0.00 | 0.00 |
April | -7.8 | 29-APR-03:00 | -8.6 | -10.6 | 4.10 | -25.6 | 0.00 | 0.00 |
May | -2.8 | 08-MAY-00:10 | -3.3 | -3.9 | 6.18 | -10.2 | 0.00 | 0.00 |
June | 0.60 | 15-JUN-03:00 | -0.4 | -1.7 | 2.60 | -15.7 | 0.00 | 0.00 |
July | 5.60 | 08-JUL-03:00 | 2.98 | 0.00 | 4.10 | -9.2 | 0.00 | 0.00 |
August | 6.70 | 17-AUG-00:00 | 4.32 | 1.70 | 2.60 | -7.1 | 0.00 | 0.00 |
September | 0.00 | 17-SEP-02:00 | -1.5 | -3.9 | 4.10 | -16.8 | 0.00 | 0.00 |
October | -6.1 | 10-OCT-05:19 | -6.6 | -7.8 | 3.77 | -20.6 | 0.00 | 0.00 |
November | -16.7 | 26-NOV-07:00 | -17.3 | -20.6 | 4.60 | -33.8 | 19.50 | 94.00 |
December | -28.3 | 29-DEC-08:00 | -28.5 | -32.2 | 2.10 | -48.7 | 69.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -33.9 | -34.0 | -37.8 | 2.10 | -54.3 | 0.00 | 0.00 | |
Maximum of Months | 6.70 | 4.32 | 1.70 | 6.18 | -7.1 | 69.50 | 94.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.17 | 13-JAN-14:00 | 10.00 | 0.00 | 8.80 | -3.0 | 40.00 | 694.00 |
February | 7.20 | 27-FEB-14:00 | 18.90 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 6.92 | 14-MAR-13:00 | 15.00 | -1.7 | 10.30 | 1.80 | 241.00 | 538.00 |
April | 11.00 | 06-APR-15:00 | 22.20 | 1.10 | 3.60 | 5.33 | 110.00 | 779.00 |
May | 15.19 | 20-MAY-15:00 | 30.00 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 19.18 | 20-JUN-14:00 | 29.40 | 14.40 | 2.60 | 18.28 | 204.00 | 614.00 |
July | 19.19 | 19-JUL-11:00 | 29.40 | 14.40 | 8.80 | 19.52 | 306.50 | 563.50 |
August | 17.61 | 05-AUG-15:00 | 35.60 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 20.11 | 07-SEP-15:20 | 25.17 | 17.93 | 4.10 | 15.88 | 127.67 | 652.00 |
October | 11.58 | 18-OCT-14:00 | 25.00 | -0.6 | 7.70 | 7.55 | 40.50 | 852.00 |
November | 8.87 | 17-NOV-16:00 | 17.20 | 1.10 | 11.30 | 4.10 | 0.00 | 0.00 |
December | 7.61 | 19-DEC-14:00 | 12.80 | 2.80 | 8.20 | 1.37 | 74.00 | 138.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 5.17 | 10.00 | -7.8 | 2.60 | -3.0 | 0.00 | 0.00 | |
Maximum of Months | 20.11 | 35.60 | 17.93 | 11.30 | 22.47 | 306.50 | 852.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.70 | 12-JAN-14:00 | 7.20 | 4.47 | 5.20 | -1.0 | 107.00 | 61.00 |
February | -0.6 | 11-FEB-08:00 | 4.40 | 2.15 | 10.80 | -5.7 | 69.50 | 50.50 |
March | -0.6 | 10-MAR-12:00 | 8.90 | 4.49 | 10.30 | -2.3 | 253.00 | 140.50 |
April | 6.10 | 17-APR-16:19 | 7.97 | 6.96 | 4.50 | 0.84 | 201.50 | 117.50 |
May | 12.20 | 02-MAY-12:00 | 18.90 | 14.60 | 12.90 | 14.84 | 108.50 | 934.50 |
June | 15.60 | 20-JUN-19:00 | 25.60 | 18.75 | 3.60 | 20.22 | 17.50 | 17.00 |
July | 16.70 | 18-JUL-21:00 | 19.40 | 17.51 | 4.10 | 16.49 | 0.00 | 0.00 |
August | 11.10 | 08-AUG-11:00 | 26.70 | 16.73 | 2.60 | 12.03 | 134.50 | 869.00 |
September | 18.30 | 07-SEP-14:00 | 24.40 | 20.09 | 4.10 | 15.57 | 111.00 | 720.00 |
October | 6.70 | 01-OCT-14:09 | 9.08 | 7.77 | 2.10 | 4.06 | 260.33 | 0.33 |
November | 3.30 | 16-NOV-19:00 | 10.60 | 6.87 | 9.80 | -1.7 | 0.00 | 0.00 |
December | 2.80 | 19-DEC-14:09 | 10.97 | 6.80 | 10.78 | -1.0 | 95.00 | 292.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.6 | 4.40 | 2.15 | 2.10 | -5.7 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 26.70 | 20.09 | 12.90 | 20.22 | 260.33 | 934.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 5.41 | 12.59 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 4.46 | 20.37 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 5.03 | 30.19 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 7.01 | 37.07 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 9.90 | 46.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 12.91 | 55.45 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 15.24 | 57.38 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 16.26 | 48.01 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 15.67 | 34.51 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.64 | 22.84 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 10.74 | 14.52 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 7.74 | 10.24 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 10.37 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 4.46 | 10.24 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 16.26 | 57.38 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.389291E+09 | -263105396.3 | 0.00 | 0.00 | 744.00 | 0.00 | -126185524.1 | 58.99 | 0.00 | 0.00 |
February | 0.356225E+09 | -243114568.8 | 0.00 | 0.00 | 672.00 | 0.00 | -113110883.7 | 58.99 | 0.00 | 0.00 |
March | 0.395460E+09 | -270552825.7 | 0.00 | 0.00 | 744.00 | 0.00 | -124907517.0 | 58.99 | 0.00 | 0.00 |
April | 0.367199E+09 | -249341904.9 | 0.00 | 0.00 | 720.00 | 0.00 | -117856964.7 | 58.99 | 0.00 | 0.00 |
May | 0.362503E+09 | -243592297.9 | 0.00 | 0.00 | 744.00 | 0.00 | -118910885.6 | 58.99 | 0.00 | 0.00 |
June | 0.333695E+09 | -223305871.7 | 0.00 | 0.00 | 720.00 | 0.00 | -110389165.5 | 58.99 | 0.00 | 0.00 |
July | 0.327645E+09 | -214920096.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112725388.1 | 58.99 | 0.00 | 0.00 |
August | 0.327050E+09 | -214075600.0 | 0.00 | 0.00 | 744.00 | 0.00 | -112974626.0 | 58.99 | 0.00 | 0.00 |
September | 0.319172E+09 | -207992606.5 | 0.00 | 0.00 | 720.00 | 0.00 | -111179877.0 | 58.99 | 0.00 | 0.00 |
October | 0.340688E+09 | -222698040.8 | 0.00 | 0.00 | 744.00 | 0.00 | -117989780.7 | 58.99 | 0.00 | 0.00 |
November | 0.347296E+09 | -228640555.1 | 0.00 | 0.00 | 720.00 | 0.00 | -118655730.3 | 58.99 | 0.00 | 0.00 |
December | 0.377339E+09 | -251954542.8 | 0.00 | 0.00 | 744.00 | 0.00 | -125384729.7 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.424357E+10 | -.283329E+10 | 8760.00 | -.141027E+10 | 58.99 | |||||
Minimum of Months | 0.319172E+09 | -270552825.7 | 0.00 | 0.00 | 672.00 | 0.00 | -126185524.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.395460E+09 | -207992606.5 | 0.00 | 0.00 | 744.00 | 0.00 | -110389165.5 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.387706E+09 | -263096112.5 | 0.00 | 0.00 | 744.00 | 0.00 | -124610108.5 | 59.00 | 0.00 | 0.00 |
February | 0.354199E+09 | -243117298.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111081680.1 | 58.99 | 0.00 | 0.00 |
March | 0.393048E+09 | -270546255.5 | 0.00 | 0.00 | 744.00 | 0.00 | -122501484.4 | 58.99 | 0.00 | 0.00 |
April | 0.364582E+09 | -249338761.4 | 0.00 | 0.00 | 720.00 | 0.00 | -115243559.0 | 58.99 | 0.00 | 0.00 |
May | 0.360761E+09 | -243591566.0 | 0.00 | 0.00 | 744.00 | 0.00 | -117169362.6 | 58.99 | 0.00 | 0.00 |
June | 0.333103E+09 | -223301842.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109801552.8 | 58.99 | 0.00 | 0.00 |
July | 0.327529E+09 | -214922210.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112606979.0 | 58.99 | 0.00 | 0.00 |
August | 0.326851E+09 | -214077184.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112773824.3 | 58.99 | 0.00 | 0.00 |
September | 0.318385E+09 | -207987563.7 | 0.00 | 0.00 | 720.00 | 0.00 | -110397277.3 | 58.99 | 0.00 | 0.00 |
October | 0.338924E+09 | -222687192.5 | 0.00 | 0.00 | 744.00 | 0.00 | -116236370.8 | 58.99 | 0.00 | 0.00 |
November | 0.345240E+09 | -228639819.1 | 0.00 | 0.00 | 720.00 | 0.00 | -116600421.4 | 58.99 | 0.00 | 0.00 |
December | 0.375446E+09 | -251976959.7 | 0.00 | 0.00 | 744.00 | 0.00 | -123468686.6 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.422577E+10 | -.283328E+10 | 8760.00 | -.139249E+10 | 58.99 | |||||
Minimum of Months | 0.318385E+09 | -270546255.5 | 0.00 | 0.00 | 672.00 | 0.00 | -124610108.5 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.393048E+09 | -207987563.7 | 0.00 | 0.00 | 744.00 | 0.00 | -109801552.8 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.358536E+09 | -231384901.2 | 0.00 | 0.00 | 744.00 | 0.00 | -127150685.3 | 58.99 | 0.00 | 0.00 |
February | 0.327408E+09 | -213964220.7 | 0.00 | 0.00 | 672.00 | 0.00 | -113443929.4 | 58.99 | 0.00 | 0.00 |
March | 0.366552E+09 | -241638858.9 | 0.00 | 0.00 | 744.00 | 0.00 | -124912975.1 | 58.99 | 0.00 | 0.00 |
April | 0.336749E+09 | -219118459.0 | 0.00 | 0.00 | 720.00 | 0.00 | -117630228.2 | 59.00 | 0.00 | 0.00 |
May | 0.334471E+09 | -216061746.6 | 0.00 | 0.00 | 744.00 | 0.00 | -118409243.7 | 58.99 | 0.00 | 0.00 |
June | 0.308192E+09 | -199000904.8 | 0.00 | 0.00 | 720.00 | 0.00 | -109190927.1 | 58.99 | 0.00 | 0.00 |
July | 0.298653E+09 | -187732873.5 | 0.00 | 0.00 | 744.00 | 0.00 | -110920148.9 | 58.99 | 0.00 | 0.00 |
August | 0.302833E+09 | -191356487.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111476341.9 | 58.99 | 0.00 | 0.00 |
September | 0.292876E+09 | -182664748.7 | 0.00 | 0.00 | 720.00 | 0.00 | -110211202.7 | 58.99 | 0.00 | 0.00 |
October | 0.313892E+09 | -195852059.7 | 0.00 | 0.00 | 744.00 | 0.00 | -118040128.2 | 58.99 | 0.00 | 0.00 |
November | 0.321033E+09 | -201902269.5 | 0.00 | 0.00 | 720.00 | 0.00 | -119130660.0 | 58.98 | 0.00 | 0.00 |
December | 0.345939E+09 | -219917794.5 | 0.00 | 0.00 | 744.00 | 0.00 | -126020756.0 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.390713E+10 | -.250060E+10 | 8760.00 | -.140654E+10 | 58.99 | |||||
Minimum of Months | 0.292876E+09 | -241638858.9 | 0.00 | 0.00 | 672.00 | 0.00 | -127150685.3 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.366552E+09 | -182664748.7 | 0.00 | 0.00 | 744.00 | 0.00 | -109190927.1 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.359021E+09 | -231357729.0 | 0.00 | 0.00 | 744.00 | 0.00 | -127662827.6 | 59.00 | 0.00 | 0.00 |
February | 0.327969E+09 | -213954072.9 | 0.00 | 0.00 | 672.00 | 0.00 | -114015212.6 | 59.00 | 0.00 | 0.00 |
March | 0.367075E+09 | -241633555.2 | 0.00 | 0.00 | 744.00 | 0.00 | -125441671.3 | 58.99 | 0.00 | 0.00 |
April | 0.337435E+09 | -219128213.9 | 0.00 | 0.00 | 720.00 | 0.00 | -118306354.5 | 58.99 | 0.00 | 0.00 |
May | 0.335006E+09 | -216062763.1 | 0.00 | 0.00 | 744.00 | 0.00 | -118943214.3 | 58.99 | 0.00 | 0.00 |
June | 0.308374E+09 | -199005665.3 | 0.00 | 0.00 | 720.00 | 0.00 | -109368232.6 | 58.99 | 0.00 | 0.00 |
July | 0.298684E+09 | -187735383.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110948253.6 | 58.99 | 0.00 | 0.00 |
August | 0.302891E+09 | -191357653.6 | 0.00 | 0.00 | 744.00 | 0.00 | -111533731.4 | 58.99 | 0.00 | 0.00 |
September | 0.293140E+09 | -182668933.8 | 0.00 | 0.00 | 720.00 | 0.00 | -110471372.7 | 58.99 | 0.00 | 0.00 |
October | 0.314547E+09 | -195855116.0 | 0.00 | 0.00 | 744.00 | 0.00 | -118692047.9 | 58.99 | 0.00 | 0.00 |
November | 0.321722E+09 | -201830368.3 | 0.00 | 0.00 | 720.00 | 0.00 | -119891345.7 | 59.01 | 0.00 | 0.00 |
December | 0.346492E+09 | -219924843.4 | 0.00 | 0.00 | 744.00 | 0.00 | -126567444.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.391236E+10 | -.250051E+10 | 8760.00 | -.141184E+10 | 58.99 | |||||
Minimum of Months | 0.293140E+09 | -241633555.2 | 0.00 | 0.00 | 672.00 | 0.00 | -127662827.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.367075E+09 | -182668933.8 | 0.00 | 0.00 | 744.00 | 0.00 | -109368232.6 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.347768E+09 | -218677093.5 | 0.00 | 0.00 | 744.00 | 0.00 | -129091296.6 | 58.99 | 0.00 | 0.00 |
February | 0.317784E+09 | -202333881.7 | 0.00 | 0.00 | 672.00 | 0.00 | -115449926.8 | 58.99 | 0.00 | 0.00 |
March | 0.355470E+09 | -228640084.1 | 0.00 | 0.00 | 744.00 | 0.00 | -126829700.2 | 58.99 | 0.00 | 0.00 |
April | 0.327197E+09 | -207345899.0 | 0.00 | 0.00 | 720.00 | 0.00 | -119851276.5 | 59.00 | 0.00 | 0.00 |
May | 0.324741E+09 | -204311127.2 | 0.00 | 0.00 | 744.00 | 0.00 | -120430182.0 | 59.00 | 0.00 | 0.00 |
June | 0.298614E+09 | -188308338.6 | 0.00 | 0.00 | 720.00 | 0.00 | -110305545.0 | 58.99 | 0.00 | 0.00 |
July | 0.289270E+09 | -177570823.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111699210.2 | 58.98 | 0.00 | 0.00 |
August | 0.293415E+09 | -181080508.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112334593.8 | 58.99 | 0.00 | 0.00 |
September | 0.284195E+09 | -172815682.2 | 0.00 | 0.00 | 720.00 | 0.00 | -111379682.2 | 59.01 | 0.00 | 0.00 |
October | 0.305212E+09 | -185114482.5 | 0.00 | 0.00 | 744.00 | 0.00 | -120097981.8 | 58.99 | 0.00 | 0.00 |
November | 0.311929E+09 | -190657105.1 | 0.00 | 0.00 | 720.00 | 0.00 | -121271934.2 | 58.99 | 0.00 | 0.00 |
December | 0.336107E+09 | -208005837.7 | 0.00 | 0.00 | 744.00 | 0.00 | -128101658.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.379170E+10 | -.236486E+10 | 8760.00 | -.142684E+10 | 58.99 | |||||
Minimum of Months | 0.284195E+09 | -228640084.1 | 0.00 | 0.00 | 672.00 | 0.00 | -129091296.6 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.355470E+09 | -172815682.2 | 0.00 | 0.00 | 744.00 | 0.00 | -110305545.0 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.347668E+09 | -218675234.6 | 0.00 | 0.00 | 744.00 | 0.00 | -128992447.5 | 58.99 | 0.00 | 0.00 |
February | 0.317703E+09 | -202330766.5 | 0.00 | 0.00 | 672.00 | 0.00 | -115372562.4 | 58.99 | 0.00 | 0.00 |
March | 0.355406E+09 | -228640111.6 | 0.00 | 0.00 | 744.00 | 0.00 | -126766233.8 | 58.99 | 0.00 | 0.00 |
April | 0.327164E+09 | -207361202.9 | 0.00 | 0.00 | 720.00 | 0.00 | -119803125.3 | 58.99 | 0.00 | 0.00 |
May | 0.324743E+09 | -204339683.0 | 0.00 | 0.00 | 744.00 | 0.00 | -120402866.3 | 58.99 | 0.00 | 0.00 |
June | 0.298673E+09 | -188312595.3 | 0.00 | 0.00 | 720.00 | 0.00 | -110360499.0 | 58.99 | 0.00 | 0.00 |
July | 0.289374E+09 | -177569312.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111804739.7 | 58.98 | 0.00 | 0.00 |
August | 0.293506E+09 | -181077690.2 | 0.00 | 0.00 | 744.00 | 0.00 | -112428306.2 | 58.99 | 0.00 | 0.00 |
September | 0.284236E+09 | -172818677.3 | 0.00 | 0.00 | 720.00 | 0.00 | -111417649.5 | 59.01 | 0.00 | 0.00 |
October | 0.305211E+09 | -185111623.7 | 0.00 | 0.00 | 744.00 | 0.00 | -120099498.0 | 58.99 | 0.00 | 0.00 |
November | 0.311885E+09 | -190656069.0 | 0.00 | 0.00 | 720.00 | 0.00 | -121228736.4 | 58.99 | 0.00 | 0.00 |
December | 0.336007E+09 | -208006190.1 | 0.00 | 0.00 | 744.00 | 0.00 | -128000444.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.379158E+10 | -.236490E+10 | 8760.00 | -.142668E+10 | 58.99 | |||||
Minimum of Months | 0.284236E+09 | -228640111.6 | 0.00 | 0.00 | 672.00 | 0.00 | -128992447.5 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.355406E+09 | -172818677.3 | 0.00 | 0.00 | 744.00 | 0.00 | -110360499.0 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.347727E+09 | -218676573.2 | 0.00 | 0.00 | 744.00 | 0.00 | -129050679.6 | 58.99 | 0.00 | 0.00 |
February | 0.317785E+09 | -202335027.2 | 0.00 | 0.00 | 672.00 | 0.00 | -115449668.3 | 58.99 | 0.00 | 0.00 |
March | 0.355516E+09 | -228639389.9 | 0.00 | 0.00 | 744.00 | 0.00 | -126876870.2 | 58.99 | 0.00 | 0.00 |
April | 0.327368E+09 | -207347782.8 | 0.00 | 0.00 | 720.00 | 0.00 | -120019998.4 | 59.00 | 0.00 | 0.00 |
May | 0.324936E+09 | -204312150.3 | 0.00 | 0.00 | 744.00 | 0.00 | -120623457.6 | 59.00 | 0.00 | 0.00 |
June | 0.298828E+09 | -188308455.6 | 0.00 | 0.00 | 720.00 | 0.00 | -110519506.5 | 58.99 | 0.00 | 0.00 |
July | 0.289479E+09 | -177533446.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111945317.7 | 59.00 | 0.00 | 0.00 |
August | 0.293593E+09 | -181071185.2 | 0.00 | 0.00 | 744.00 | 0.00 | -112521463.9 | 58.99 | 0.00 | 0.00 |
September | 0.284361E+09 | -172859382.4 | 0.00 | 0.00 | 720.00 | 0.00 | -111501395.7 | 58.99 | 0.00 | 0.00 |
October | 0.305406E+09 | -185118605.1 | 0.00 | 0.00 | 744.00 | 0.00 | -120287603.1 | 58.99 | 0.00 | 0.00 |
November | 0.312006E+09 | -190659266.6 | 0.00 | 0.00 | 720.00 | 0.00 | -121347144.0 | 58.99 | 0.00 | 0.00 |
December | 0.336090E+09 | -208007670.7 | 0.00 | 0.00 | 744.00 | 0.00 | -128082708.6 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.379309E+10 | -.236487E+10 | 8760.00 | -.142823E+10 | 58.99 | |||||
Minimum of Months | 0.284361E+09 | -228639389.9 | 0.00 | 0.00 | 672.00 | 0.00 | -129050679.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.355516E+09 | -172859382.4 | 0.00 | 0.00 | 744.00 | 0.00 | -110519506.5 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 275.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 304.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 325.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 385.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 417.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 421.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 352.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 317.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 269.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 236.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3965.83 | ||||||||||
Minimum of Months | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.362037E+11 | 79194.80 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.198272E+11 | 79194.80 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.158018E+11 | 79194.80 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.549179E+10 | 79194.80 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.333376E+10 | 79194.80 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.111624E+09 | 22995.56 | 17-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.467024E+09 | 79194.80 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188347E+10 | 79194.80 | 05-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.105373E+11 | 79194.80 | 03-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.255429E+11 | 79194.80 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.119201E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.362037E+11 | 79194.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.137321E+11 | 40936.51 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.720902E+10 | 40936.51 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.512081E+10 | 40936.51 | 03-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.160095E+10 | 40936.51 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.100070E+10 | 40936.51 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 23462827.25 | 2372.73 | 16-JUN-11:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.118589E+09 | 17049.52 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.542529E+09 | 39275.07 | 10-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.354912E+10 | 40936.51 | 12-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.933857E+10 | 40936.51 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.422359E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.137321E+11 | 40936.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.158897E+11 | 39598.60 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.886748E+10 | 39598.60 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.697328E+10 | 39598.60 | 03-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.254262E+10 | 39598.60 | 01-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.162010E+10 | 39598.60 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 54647376.51 | 3264.35 | 16-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.278589E+09 | 17559.49 | 20-SEP-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.109035E+10 | 39598.60 | 10-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.495935E+10 | 39598.60 | 11-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.114260E+11 | 39598.60 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.537021E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.158897E+11 | 39598.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.163322E+11 | 39664.03 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.920189E+10 | 39664.03 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.735389E+10 | 39664.03 | 03-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.278974E+10 | 39664.03 | 01-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.177546E+10 | 39664.03 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 63335343.09 | 3466.92 | 16-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.329923E+09 | 21977.16 | 20-SEP-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.124255E+10 | 39664.03 | 10-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.529364E+10 | 39664.03 | 11-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.118262E+11 | 39664.03 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.562088E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.163322E+11 | 39664.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.167605E+11 | 39823.82 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.953855E+10 | 39823.82 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.771386E+10 | 39823.82 | 01-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.302577E+10 | 39823.82 | 01-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.192425E+10 | 39823.82 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 73104732.98 | 3682.46 | 16-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 561369.77 | 125.43 | 17-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.373380E+09 | 25034.29 | 20-SEP-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.137089E+10 | 39823.82 | 10-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.558805E+10 | 39823.82 | 11-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.122134E+11 | 39823.82 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.585823E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.167605E+11 | 39823.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.317165E+11 | 75830.85 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.181608E+11 | 75830.85 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.148050E+11 | 75830.85 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.597584E+10 | 75830.85 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.379371E+10 | 75830.85 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.163247E+09 | 32222.88 | 17-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 15359541.84 | 1389.21 | 17-AUG-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.806688E+09 | 75830.85 | 19-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.281454E+10 | 75830.85 | 04-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.109077E+11 | 75830.85 | 02-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232001E+11 | 75830.85 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.112359E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.317165E+11 | 75830.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.164714E+11 | 40228.09 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.942099E+10 | 40228.09 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.768728E+10 | 40228.09 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.309151E+10 | 40228.09 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196489E+10 | 40228.09 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 82996656.44 | 17076.54 | 17-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 7690437.56 | 705.40 | 17-AUG-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.408735E+09 | 40228.09 | 19-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142970E+10 | 40228.09 | 04-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.563175E+10 | 40228.09 | 02-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120393E+11 | 40228.09 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.582363E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.164714E+11 | 40228.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.165439E+11 | 40203.39 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.950265E+10 | 40203.39 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.779938E+10 | 40203.39 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.319359E+10 | 40203.39 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.202763E+10 | 40203.39 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 89244179.37 | 20074.37 | 17-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 9983618.99 | 810.75 | 17-AUG-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.428857E+09 | 40203.39 | 19-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148257E+10 | 40203.39 | 04-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.572399E+10 | 40203.39 | 02-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.121291E+11 | 40203.39 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.589310E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.165439E+11 | 40203.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.170062E+11 | 40449.44 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.989646E+10 | 40449.44 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.828637E+10 | 40449.44 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.357496E+10 | 40449.44 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.226151E+10 | 40449.44 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.111914E+09 | 31669.26 | 17-JUN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 17730121.91 | 7381.97 | 18-AUG-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.494419E+09 | 40449.44 | 19-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.165931E+10 | 40449.44 | 04-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.606368E+10 | 40449.44 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125539E+11 | 40449.44 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.619264E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.170062E+11 | 40449.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.212977E+11 | 43840.26 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127108E+11 | 43840.26 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.110570E+11 | 43840.26 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.522157E+10 | 43840.26 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.328756E+10 | 43840.26 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.224718E+09 | 43840.26 | 16-JUN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1433361.78 | 1234.16 | 08-JUL-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 65304338.84 | 38853.58 | 18-AUG-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.774539E+09 | 43840.26 | 12-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.234044E+10 | 43840.26 | 02-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.771752E+10 | 43840.26 | 01-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.155392E+11 | 43840.26 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.802377E+11 | |||||||
Minimum of Months | 1433361.78 | 1234.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.212977E+11 | 43840.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 1565.58 | 1565.58 | 0.33 | 27-FEB-15:30 | 0.33 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 99751617.51 | 99751617.51 | 7232.23 | 07-APR-14:00 | 7232.23 | 0.00 |
May | 0.00 | 0.00 | 0.244347E+10 | 0.243537E+10 | 19732.45 | 20-MAY-16:10 | 19732.45 | 0.00 |
June | 0.00 | 0.00 | 0.995877E+10 | 0.954090E+10 | 24645.12 | 20-JUN-17:00 | 20947.46 | 0.00 |
July | 0.00 | 0.00 | 0.200760E+11 | 0.195807E+11 | 42605.07 | 17-JUL-07:02 | 39325.11 | 0.00 |
August | 0.00 | 0.00 | 0.159774E+11 | 0.159026E+11 | 37849.94 | 07-AUG-07:02 | 37849.94 | 0.00 |
September | 0.00 | 0.00 | 0.840698E+10 | 0.799572E+10 | 41504.53 | 05-SEP-07:02 | 36735.23 | 0.00 |
October | 0.00 | 0.00 | 0.822607E+09 | 0.822607E+09 | 15908.25 | 18-OCT-15:00 | 15908.25 | 0.00 |
November | 0.00 | 0.00 | 4803.00 | 4803.00 | 0.35 | 04-NOV-14:00 | 0.35 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.577851E+11 | 0.563777E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.200760E+11 | 0.195807E+11 | 42605.07 | 39325.11 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 4333.91 | 4333.91 | 7.22 | 14-JAN-21:40 | 7.22 | 0.00 |
February | 0.00 | 0.00 | 1446812.90 | 1446812.90 | 417.63 | 26-FEB-23:10 | 417.63 | 0.00 |
March | 0.00 | 0.00 | 59246.41 | 59246.41 | 46.45 | 26-MAR-20:10 | 46.45 | 0.00 |
April | 0.00 | 0.00 | 0.115890E+09 | 0.115890E+09 | 21313.94 | 06-APR-20:02 | 21313.94 | 0.00 |
May | 0.00 | 0.00 | 0.163089E+10 | 0.161947E+10 | 21723.46 | 20-MAY-18:20 | 21723.46 | 0.00 |
June | 0.00 | 0.00 | 0.588192E+10 | 0.562902E+10 | 22739.12 | 21-JUN-20:01 | 18422.11 | 0.00 |
July | 0.00 | 0.00 | 0.111036E+11 | 0.107933E+11 | 23412.80 | 18-JUL-21:58 | 13472.79 | 0.00 |
August | 0.00 | 0.00 | 0.894131E+10 | 0.888054E+10 | 22013.17 | 08-AUG-22:43 | 20508.95 | 0.00 |
September | 0.00 | 0.00 | 0.470657E+10 | 0.446782E+10 | 23106.45 | 06-SEP-20:01 | 16229.68 | 0.00 |
October | 0.00 | 0.00 | 0.511110E+09 | 0.511110E+09 | 21313.94 | 02-OCT-20:02 | 21313.94 | 0.00 |
November | 0.00 | 0.00 | 16613291.15 | 16613291.15 | 21313.94 | 04-NOV-18:15 | 21313.94 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.329094E+11 | 0.320352E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.111036E+11 | 0.107933E+11 | 23412.80 | 21723.46 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 691.58 | 691.58 | 0.13 | 27-FEB-15:30 | 0.13 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 41950851.24 | 41950851.24 | 3491.68 | 07-APR-14:00 | 3491.68 | 0.00 |
May | 0.00 | 0.00 | 0.886325E+09 | 0.883476E+09 | 9631.10 | 20-MAY-16:00 | 9631.10 | 0.00 |
June | 0.00 | 0.00 | 0.393884E+10 | 0.378972E+10 | 15104.09 | 22-JUN-06:02 | 10231.08 | 0.00 |
July | 0.00 | 0.00 | 0.776110E+10 | 0.758953E+10 | 22183.73 | 19-JUL-06:03 | 14862.36 | 0.00 |
August | 0.00 | 0.00 | 0.628043E+10 | 0.624974E+10 | 20392.05 | 07-AUG-06:02 | 20392.05 | 0.00 |
September | 0.00 | 0.00 | 0.309933E+10 | 0.293993E+10 | 21211.59 | 07-SEP-06:02 | 13463.47 | 0.00 |
October | 0.00 | 0.00 | 0.322703E+09 | 0.322703E+09 | 7528.61 | 18-OCT-14:00 | 7528.61 | 0.00 |
November | 0.00 | 0.00 | 1116.09 | 1116.09 | 0.17 | 04-NOV-15:10 | 0.17 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.223307E+11 | 0.218170E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.776110E+10 | 0.758953E+10 | 22183.73 | 20392.05 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 666.84 | 666.84 | 0.17 | 27-FEB-14:40 | 0.17 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 33672616.96 | 33672616.96 | 3228.83 | 07-APR-14:00 | 3228.83 | 0.00 |
May | 0.00 | 0.00 | 0.843213E+09 | 0.840635E+09 | 9495.68 | 20-MAY-16:00 | 9495.68 | 0.00 |
June | 0.00 | 0.00 | 0.387261E+10 | 0.372595E+10 | 14317.51 | 22-JUN-06:02 | 9691.94 | 0.00 |
July | 0.00 | 0.00 | 0.771755E+10 | 0.754640E+10 | 22247.58 | 19-JUL-06:03 | 14905.54 | 0.00 |
August | 0.00 | 0.00 | 0.622728E+10 | 0.619710E+10 | 20450.44 | 07-AUG-06:02 | 20450.44 | 0.00 |
September | 0.00 | 0.00 | 0.305381E+10 | 0.289585E+10 | 21272.46 | 07-SEP-06:02 | 13498.82 | 0.00 |
October | 0.00 | 0.00 | 0.290752E+09 | 0.290752E+09 | 7315.68 | 18-OCT-14:00 | 7315.68 | 0.00 |
November | 0.00 | 0.00 | 742.13 | 742.13 | 0.18 | 04-NOV-14:20 | 0.18 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.220389E+11 | 0.215304E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.771755E+10 | 0.754640E+10 | 22247.58 | 20450.44 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 846.98 | 846.98 | 0.22 | 27-FEB-15:40 | 0.22 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 26675001.37 | 26675001.37 | 2978.29 | 07-APR-14:00 | 2978.29 | 0.00 |
May | 0.00 | 0.00 | 0.798147E+09 | 0.795904E+09 | 9334.36 | 20-MAY-16:00 | 9334.36 | 0.00 |
June | 0.00 | 0.00 | 0.377219E+10 | 0.362974E+10 | 11583.70 | 23-JUN-14:00 | 11583.70 | 0.00 |
July | 0.00 | 0.00 | 0.758687E+10 | 0.741998E+10 | 22389.79 | 19-JUL-06:03 | 14975.54 | 0.00 |
August | 0.00 | 0.00 | 0.610717E+10 | 0.607849E+10 | 20585.29 | 07-AUG-06:02 | 20585.29 | 0.00 |
September | 0.00 | 0.00 | 0.298270E+10 | 0.282811E+10 | 21070.08 | 05-SEP-06:02 | 18408.20 | 0.00 |
October | 0.00 | 0.00 | 0.263555E+09 | 0.263555E+09 | 7114.91 | 18-OCT-14:00 | 7114.91 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.215373E+11 | 0.210425E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.758687E+10 | 0.741998E+10 | 22389.79 | 20585.29 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 305.42 | 305.42 | 0.20 | 27-FEB-15:40 | 0.20 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 32185229.83 | 32185229.83 | 4578.81 | 07-APR-14:00 | 4578.81 | 0.00 |
May | 0.00 | 0.00 | 0.135550E+10 | 0.135121E+10 | 16973.29 | 20-MAY-16:00 | 16973.29 | 0.00 |
June | 0.00 | 0.00 | 0.684806E+10 | 0.655624E+10 | 21243.02 | 29-JUN-15:00 | 21243.02 | 0.00 |
July | 0.00 | 0.00 | 0.138464E+11 | 0.135240E+11 | 41531.32 | 19-JUL-07:03 | 28312.34 | 0.00 |
August | 0.00 | 0.00 | 0.111366E+11 | 0.110822E+11 | 38873.44 | 07-AUG-07:02 | 38873.44 | 0.00 |
September | 0.00 | 0.00 | 0.530081E+10 | 0.499763E+10 | 39636.63 | 04-SEP-08:62 | 39636.63 | 0.00 |
October | 0.00 | 0.00 | 0.419660E+09 | 0.419660E+09 | 12756.24 | 18-OCT-14:40 | 12756.24 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.389393E+11 | 0.379631E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.138464E+11 | 0.135240E+11 | 41531.32 | 39636.63 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 15242124.94 | 15242124.94 | 2379.30 | 07-APR-14:00 | 2379.30 | 0.00 |
May | 0.00 | 0.00 | 0.702647E+09 | 0.700762E+09 | 8951.22 | 20-MAY-16:00 | 8951.22 | 0.00 |
June | 0.00 | 0.00 | 0.356442E+10 | 0.341686E+10 | 11156.98 | 29-JUN-15:00 | 11156.98 | 0.00 |
July | 0.00 | 0.00 | 0.723065E+10 | 0.706774E+10 | 22019.25 | 17-JUL-07:02 | 20281.99 | 0.00 |
August | 0.00 | 0.00 | 0.580362E+10 | 0.577765E+10 | 21197.71 | 07-AUG-07:02 | 21197.71 | 0.00 |
September | 0.00 | 0.00 | 0.275218E+10 | 0.259917E+10 | 21613.37 | 04-SEP-08:62 | 21613.37 | 0.00 |
October | 0.00 | 0.00 | 0.211196E+09 | 0.211196E+09 | 6752.13 | 18-OCT-14:40 | 6752.13 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.202800E+11 | 0.197886E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.723065E+10 | 0.706774E+10 | 22019.25 | 21613.37 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 13633272.78 | 13633272.78 | 2265.11 | 07-APR-14:00 | 2265.11 | 0.00 |
May | 0.00 | 0.00 | 0.681767E+09 | 0.679969E+09 | 8844.41 | 20-MAY-16:00 | 8844.41 | 0.00 |
June | 0.00 | 0.00 | 0.350106E+10 | 0.335559E+10 | 11072.94 | 29-JUN-15:00 | 11072.94 | 0.00 |
July | 0.00 | 0.00 | 0.714681E+10 | 0.698593E+10 | 22015.12 | 17-JUL-07:02 | 20260.65 | 0.00 |
August | 0.00 | 0.00 | 0.573249E+10 | 0.570708E+10 | 21191.74 | 07-AUG-07:02 | 21191.74 | 0.00 |
September | 0.00 | 0.00 | 0.271304E+10 | 0.256188E+10 | 21607.58 | 04-SEP-08:62 | 21607.58 | 0.00 |
October | 0.00 | 0.00 | 0.200967E+09 | 0.200967E+09 | 6636.21 | 18-OCT-14:40 | 6636.21 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.199898E+11 | 0.195051E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.714681E+10 | 0.698593E+10 | 22015.12 | 21607.58 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 9471070.41 | 9471070.41 | 1934.10 | 07-APR-14:00 | 1934.10 | 0.00 |
May | 0.00 | 0.00 | 0.629559E+09 | 0.628003E+09 | 8592.76 | 20-MAY-16:00 | 8592.76 | 0.00 |
June | 0.00 | 0.00 | 0.335317E+10 | 0.321287E+10 | 10900.79 | 29-JUN-15:00 | 10900.79 | 0.00 |
July | 0.00 | 0.00 | 0.697918E+10 | 0.682343E+10 | 22235.37 | 17-JUL-07:02 | 20417.97 | 0.00 |
August | 0.00 | 0.00 | 0.558972E+10 | 0.556579E+10 | 21399.27 | 07-AUG-07:02 | 21399.27 | 0.00 |
September | 0.00 | 0.00 | 0.263074E+10 | 0.248375E+10 | 21737.11 | 04-SEP-08:62 | 21737.11 | 0.00 |
October | 0.00 | 0.00 | 0.176719E+09 | 0.176719E+09 | 6364.64 | 18-OCT-14:50 | 6364.64 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.193686E+11 | 0.189000E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.697918E+10 | 0.682343E+10 | 22235.37 | 21737.11 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 2080559.60 | 2080559.60 | 969.70 | 07-APR-14:00 | 969.70 | 0.00 |
May | 0.00 | 0.00 | 0.545212E+09 | 0.543940E+09 | 8305.19 | 20-MAY-16:00 | 8305.19 | 0.00 |
June | 0.00 | 0.00 | 0.320350E+10 | 0.306678E+10 | 10947.57 | 23-JUN-14:00 | 10947.57 | 0.00 |
July | 0.00 | 0.00 | 0.697604E+10 | 0.682167E+10 | 17777.83 | 17-JUL-07:02 | 16231.87 | 0.00 |
August | 0.00 | 0.00 | 0.554480E+10 | 0.552294E+10 | 13982.02 | 06-AUG-16:00 | 13982.02 | 0.00 |
September | 0.00 | 0.00 | 0.256381E+10 | 0.242624E+10 | 22144.71 | 04-SEP-08:62 | 22144.71 | 0.00 |
October | 0.00 | 0.00 | 0.143936E+09 | 0.143936E+09 | 6117.49 | 18-OCT-14:40 | 6117.49 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.189794E+11 | 0.185276E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.697604E+10 | 0.682167E+10 | 22144.71 | 22144.71 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.518382E+10 | 0.76 | 2836.83 | 01-JAN-08:25 | 1.03 |
February | 0.466700E+10 | 0.72 | 2836.83 | 01-FEB-08:40 | 1.03 |
March | 0.516521E+10 | 0.71 | 2836.83 | 01-MAR-08:30 | 1.03 |
April | 0.499444E+10 | 0.70 | 2836.83 | 01-APR-11:10 | 1.03 |
May | 0.514808E+10 | 0.70 | 2836.83 | 01-MAY-08:30 | 1.03 |
June | 0.499396E+10 | 0.69 | 2836.83 | 01-JUN-13:30 | 1.02 |
July | 0.515736E+10 | 0.69 | 2836.83 | 01-JUL-12:10 | 1.02 |
August | 0.514715E+10 | 0.69 | 2836.83 | 01-AUG-07:08 | 1.02 |
September | 0.500417E+10 | 0.70 | 2836.83 | 01-SEP-20:05 | 1.02 |
October | 0.514723E+10 | 0.70 | 2836.83 | 03-OCT-10:00 | 1.03 |
November | 0.497810E+10 | 0.70 | 2836.83 | 02-NOV-08:10 | 1.03 |
December | 0.517643E+10 | 0.72 | 2836.83 | 01-DEC-10:20 | 1.03 |
Annual Sum or Average | 0.607629E+11 | 0.71 | |||
Minimum of Months | 0.466700E+10 | 0.69 | 2836.83 | 1.02 | |
Maximum of Months | 0.518382E+10 | 0.76 | 2836.83 | 1.03 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.213493E+10 | 0.63 | 1553.82 | 08-JAN-08:50 | 1.08 |
February | 0.192002E+10 | 0.61 | 1553.82 | 08-FEB-16:00 | 1.07 |
March | 0.214560E+10 | 0.58 | 1553.82 | 03-MAR-21:00 | 1.08 |
April | 0.214463E+10 | 0.65 | 1553.82 | 08-APR-18:00 | 1.07 |
May | 0.236051E+10 | 0.67 | 1553.82 | 07-MAY-13:30 | 1.07 |
June | 0.245182E+10 | 0.68 | 1553.82 | 10-JUN-14:40 | 1.07 |
July | 0.247249E+10 | 0.67 | 1553.82 | 14-JUL-08:50 | 1.06 |
August | 0.251308E+10 | 0.68 | 1553.82 | 01-AUG-11:20 | 1.06 |
September | 0.241631E+10 | 0.70 | 1553.82 | 01-SEP-19:17 | 1.07 |
October | 0.232944E+10 | 0.70 | 1553.82 | 03-OCT-13:55 | 1.07 |
November | 0.208956E+10 | 0.62 | 1553.82 | 02-NOV-09:50 | 1.07 |
December | 0.210323E+10 | 0.58 | 1553.82 | 04-DEC-12:10 | 1.07 |
Annual Sum or Average | 0.270816E+11 | 0.65 | |||
Minimum of Months | 0.192002E+10 | 0.58 | 1553.82 | 1.06 | |
Maximum of Months | 0.251308E+10 | 0.70 | 1553.82 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.214490E+10 | 0.61 | 1477.55 | 01-JAN-13:50 | 1.07 |
February | 0.193651E+10 | 0.58 | 1477.55 | 01-FEB-19:00 | 1.08 |
March | 0.218140E+10 | 0.59 | 1477.55 | 01-MAR-11:50 | 1.07 |
April | 0.207448E+10 | 0.58 | 1477.55 | 02-APR-08:20 | 1.07 |
May | 0.215959E+10 | 0.58 | 1477.55 | 01-MAY-07:07 | 1.07 |
June | 0.210639E+10 | 0.59 | 1477.55 | 02-JUN-15:40 | 1.07 |
July | 0.212767E+10 | 0.57 | 1477.55 | 01-JUL-15:50 | 1.06 |
August | 0.218086E+10 | 0.59 | 1477.55 | 02-AUG-11:10 | 1.07 |
September | 0.207448E+10 | 0.58 | 1477.55 | 02-SEP-09:10 | 1.06 |
October | 0.213831E+10 | 0.58 | 1477.55 | 03-OCT-10:50 | 1.07 |
November | 0.207448E+10 | 0.58 | 1477.55 | 02-NOV-17:00 | 1.07 |
December | 0.212825E+10 | 0.58 | 1477.55 | 01-DEC-14:10 | 1.07 |
Annual Sum or Average | 0.253273E+11 | 0.58 | |||
Minimum of Months | 0.193651E+10 | 0.57 | 1477.55 | 1.06 | |
Maximum of Months | 0.218140E+10 | 0.61 | 1477.55 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.215364E+10 | 0.63 | 1481.28 | 03-JAN-10:50 | 1.07 |
February | 0.194180E+10 | 0.59 | 1481.28 | 01-FEB-11:40 | 1.08 |
March | 0.218766E+10 | 0.60 | 1481.28 | 01-MAR-12:10 | 1.07 |
April | 0.207972E+10 | 0.58 | 1481.28 | 01-APR-06:08 | 1.07 |
May | 0.216504E+10 | 0.58 | 1481.28 | 03-MAY-17:30 | 1.07 |
June | 0.211171E+10 | 0.59 | 1481.28 | 05-JUN-12:00 | 1.07 |
July | 0.213304E+10 | 0.57 | 1481.28 | 16-JUL-08:07 | 1.06 |
August | 0.218637E+10 | 0.59 | 1481.28 | 01-AUG-14:00 | 1.06 |
September | 0.207972E+10 | 0.58 | 1481.28 | 05-SEP-10:20 | 1.06 |
October | 0.214371E+10 | 0.58 | 1481.28 | 04-OCT-10:00 | 1.07 |
November | 0.207972E+10 | 0.58 | 1481.28 | 01-NOV-08:40 | 1.07 |
December | 0.213402E+10 | 0.58 | 1481.28 | 01-DEC-14:30 | 1.07 |
Annual Sum or Average | 0.253962E+11 | 0.59 | |||
Minimum of Months | 0.194180E+10 | 0.57 | 1481.28 | 1.06 | |
Maximum of Months | 0.218766E+10 | 0.63 | 1481.28 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.216926E+10 | 0.63 | 1490.39 | 03-JAN-13:40 | 1.07 |
February | 0.195440E+10 | 0.59 | 1490.39 | 02-FEB-20:20 | 1.08 |
March | 0.220163E+10 | 0.60 | 1490.39 | 01-MAR-19:10 | 1.07 |
April | 0.209251E+10 | 0.58 | 1490.39 | 06-APR-07:10 | 1.07 |
May | 0.217835E+10 | 0.58 | 1490.39 | 02-MAY-06:10 | 1.07 |
June | 0.212470E+10 | 0.59 | 1490.39 | 10-JUN-13:10 | 1.07 |
July | 0.214616E+10 | 0.57 | 1490.39 | 01-JUL-06:03 | 1.06 |
August | 0.219982E+10 | 0.59 | 1490.39 | 01-AUG-10:40 | 1.06 |
September | 0.209251E+10 | 0.58 | 1490.39 | 07-SEP-13:40 | 1.05 |
October | 0.215689E+10 | 0.58 | 1490.39 | 02-OCT-08:25 | 1.07 |
November | 0.209251E+10 | 0.58 | 1490.39 | 01-NOV-07:07 | 1.07 |
December | 0.214752E+10 | 0.58 | 1490.39 | 05-DEC-20:20 | 1.07 |
Annual Sum or Average | 0.255563E+11 | 0.59 | |||
Minimum of Months | 0.195440E+10 | 0.57 | 1490.39 | 1.05 | |
Maximum of Months | 0.220163E+10 | 0.63 | 1490.39 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.358053E+10 | 0.59 | 2652.74 | 02-JAN-13:10 | 1.03 |
February | 0.321532E+10 | 0.54 | 2652.74 | 07-FEB-09:40 | 1.03 |
March | 0.362500E+10 | 0.54 | 2652.74 | 03-MAR-08:09 | 1.03 |
April | 0.343795E+10 | 0.51 | 2652.74 | 06-APR-07:08 | 1.03 |
May | 0.358119E+10 | 0.52 | 2652.74 | 03-MAY-19:50 | 1.03 |
June | 0.349524E+10 | 0.52 | 2652.74 | 07-JUN-10:30 | 1.02 |
July | 0.352389E+10 | 0.51 | 2652.74 | 01-JUL-08:40 | 1.02 |
August | 0.361939E+10 | 0.52 | 2652.74 | 08-AUG-12:30 | 1.02 |
September | 0.343795E+10 | 0.51 | 2652.74 | 07-SEP-08:30 | 1.02 |
October | 0.354299E+10 | 0.51 | 2652.74 | 04-OCT-08:65 | 1.03 |
November | 0.343896E+10 | 0.52 | 2652.74 | 02-NOV-07:10 | 1.03 |
December | 0.353181E+10 | 0.53 | 2652.74 | 04-DEC-10:30 | 1.03 |
Annual Sum or Average | 0.420302E+11 | 0.53 | |||
Minimum of Months | 0.321532E+10 | 0.51 | 2652.74 | 1.02 | |
Maximum of Months | 0.362500E+10 | 0.59 | 2652.74 | 1.03 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.204006E+10 | 0.61 | 1513.44 | 01-JAN-09:09 | 1.07 |
February | 0.183361E+10 | 0.55 | 1513.44 | 01-FEB-08:05 | 1.07 |
March | 0.206813E+10 | 0.56 | 1513.44 | 01-MAR-08:15 | 1.07 |
April | 0.196142E+10 | 0.54 | 1513.44 | 24-APR-16:50 | 1.07 |
May | 0.204315E+10 | 0.54 | 1513.44 | 01-MAY-07:08 | 1.07 |
June | 0.199411E+10 | 0.54 | 1513.44 | 13-JUN-16:00 | 1.06 |
July | 0.201045E+10 | 0.53 | 1513.44 | 01-JUL-09:20 | 1.06 |
August | 0.206494E+10 | 0.54 | 1513.44 | 01-AUG-10:00 | 1.06 |
September | 0.196142E+10 | 0.53 | 1513.44 | 12-SEP-08:10 | 1.06 |
October | 0.202135E+10 | 0.53 | 1513.44 | 07-OCT-15:50 | 1.07 |
November | 0.196186E+10 | 0.54 | 1513.44 | 01-NOV-08:15 | 1.07 |
December | 0.201408E+10 | 0.55 | 1513.44 | 14-DEC-14:50 | 1.07 |
Annual Sum or Average | 0.239746E+11 | 0.55 | |||
Minimum of Months | 0.183361E+10 | 0.53 | 1513.44 | 1.06 | |
Maximum of Months | 0.206813E+10 | 0.61 | 1513.44 | 1.07 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.203831E+10 | 0.61 | 1512.03 | 07-JAN-08:07 | 1.08 |
February | 0.183206E+10 | 0.55 | 1512.03 | 02-FEB-11:50 | 1.08 |
March | 0.206621E+10 | 0.56 | 1512.03 | 06-MAR-14:00 | 1.07 |
April | 0.195959E+10 | 0.54 | 1512.03 | 09-APR-14:40 | 1.07 |
May | 0.204124E+10 | 0.54 | 1512.03 | 03-MAY-09:00 | 1.07 |
June | 0.199225E+10 | 0.54 | 1512.03 | 04-JUN-12:40 | 1.06 |
July | 0.200858E+10 | 0.53 | 1512.03 | 02-JUL-09:30 | 1.06 |
August | 0.206302E+10 | 0.54 | 1512.03 | 03-AUG-19:00 | 1.07 |
September | 0.195959E+10 | 0.53 | 1512.03 | 04-SEP-16:50 | 1.06 |
October | 0.201947E+10 | 0.53 | 1512.03 | 03-OCT-08:30 | 1.07 |
November | 0.196005E+10 | 0.54 | 1512.03 | 09-NOV-17:40 | 1.07 |
December | 0.201249E+10 | 0.55 | 1512.03 | 03-DEC-10:30 | 1.07 |
Annual Sum or Average | 0.239529E+11 | 0.55 | |||
Minimum of Months | 0.183206E+10 | 0.53 | 1512.03 | 1.06 | |
Maximum of Months | 0.206621E+10 | 0.61 | 1512.03 | 1.08 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.206078E+10 | 0.62 | 1526.06 | 01-JAN-10:40 | 1.07 |
February | 0.185062E+10 | 0.56 | 1526.06 | 01-FEB-08:07 | 1.07 |
March | 0.208639E+10 | 0.56 | 1526.06 | 01-MAR-08:09 | 1.07 |
April | 0.197777E+10 | 0.54 | 1526.06 | 01-APR-07:08 | 1.07 |
May | 0.206018E+10 | 0.54 | 1526.06 | 01-MAY-10:40 | 1.07 |
June | 0.201074E+10 | 0.54 | 1526.06 | 01-JUN-14:50 | 1.06 |
July | 0.202722E+10 | 0.53 | 1526.06 | 01-JUL-11:10 | 1.06 |
August | 0.208216E+10 | 0.54 | 1526.06 | 01-AUG-18:10 | 1.06 |
September | 0.197777E+10 | 0.53 | 1526.06 | 01-SEP-09:10 | 1.06 |
October | 0.203821E+10 | 0.53 | 1526.06 | 03-OCT-08:50 | 1.07 |
November | 0.197855E+10 | 0.54 | 1526.06 | 01-NOV-12:20 | 1.07 |
December | 0.203276E+10 | 0.56 | 1526.06 | 01-DEC-08:13 | 1.07 |
Annual Sum or Average | 0.241832E+11 | 0.55 | |||
Minimum of Months | 0.185062E+10 | 0.53 | 1526.06 | 1.06 | |
Maximum of Months | 0.208639E+10 | 0.62 | 1526.06 | 1.07 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.229540E+10 | 0.70 | 1650.58 | 01-JAN-09:30 | 1.03 |
February | 0.203532E+10 | 0.65 | 1650.58 | 01-FEB-08:05 | 1.03 |
March | 0.227892E+10 | 0.60 | 1650.58 | 01-MAR-08:09 | 1.03 |
April | 0.214171E+10 | 0.52 | 1650.58 | 01-APR-07:10 | 1.03 |
May | 0.223227E+10 | 0.54 | 1650.58 | 01-MAY-07:03 | 1.03 |
June | 0.217481E+10 | 0.52 | 1650.58 | 02-JUN-08:20 | 1.02 |
July | 0.219263E+10 | 0.51 | 1650.58 | 01-JUL-09:00 | 1.02 |
August | 0.225205E+10 | 0.52 | 1650.58 | 01-AUG-10:50 | 1.02 |
September | 0.213915E+10 | 0.51 | 1650.58 | 01-SEP-10:00 | 1.02 |
October | 0.220456E+10 | 0.51 | 1650.58 | 01-OCT-08:63 | 1.02 |
November | 0.215041E+10 | 0.55 | 1650.58 | 01-NOV-08:65 | 1.03 |
December | 0.223219E+10 | 0.63 | 1650.58 | 01-DEC-08:03 | 1.03 |
Annual Sum or Average | 0.263294E+11 | 0.56 | |||
Minimum of Months | 0.203532E+10 | 0.51 | 1650.58 | 1.02 | |
Maximum of Months | 0.229540E+10 | 0.70 | 1650.58 | 1.03 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.07 | 0.24 |
February | 2.01 | 0.42 |
March | 1.39 | 0.49 |
April | 0.80 | 1.24 |
May | 0.06 | 1.50 |
June | 0.28 | 0.75 |
July | 0.67 | 0.12 |
August | 0.28 | 0.00 |
September | 0.33 | 0.44 |
October | 0.58 | 1.36 |
November | 0.58 | 0.79 |
December | 1.63 | 0.41 |
Annual Sum or Average | 10.68 | 0.51 |
Minimum of Months | 0.06 | 0.00 |
Maximum of Months | 2.07 | 1.50 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.76 | 2.89 |
February | 0.61 | 4.66 |
March | 1.41 | 3.95 |
April | 1.85 | 5.00 |
May | 2.72 | 4.67 |
June | 4.57 | 3.80 |
July | 5.56 | 2.57 |
August | 5.25 | 3.11 |
September | 3.36 | 3.15 |
October | 1.21 | 3.98 |
November | 1.03 | 4.90 |
December | 0.59 | 2.23 |
Annual Sum or Average | 28.91 | 3.54 |
Minimum of Months | 0.59 | 2.23 |
Maximum of Months | 5.56 | 5.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.99 | 0.00 |
February | 0.33 | 0.00 |
March | 0.02 | 0.00 |
April | 0.81 | 0.21 |
May | 1.30 | 0.46 |
June | 2.06 | 0.72 |
July | 2.73 | 0.73 |
August | 1.75 | 0.75 |
September | 1.56 | 0.72 |
October | 1.21 | 0.54 |
November | 0.50 | 0.46 |
December | 0.47 | 0.00 |
Annual Sum or Average | 13.72 | 0.55 |
Minimum of Months | 0.02 | 0.00 |
Maximum of Months | 2.73 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.26 | 0.00 |
February | 0.47 | 0.00 |
March | 0.02 | 0.00 |
April | 0.22 | 0.75 |
May | 1.19 | 0.43 |
June | 1.90 | 0.75 |
July | 2.61 | 0.73 |
August | 1.75 | 0.75 |
September | 1.47 | 0.64 |
October | 0.99 | 0.50 |
November | 0.50 | 0.33 |
December | 0.50 | 0.00 |
Annual Sum or Average | 12.89 | 0.54 |
Minimum of Months | 0.02 | 0.00 |
Maximum of Months | 2.61 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.42 | 0.00 |
February | 0.39 | 0.00 |
March | 0.11 | 0.00 |
April | 0.22 | 0.75 |
May | 0.85 | 0.53 |
June | 1.90 | 0.75 |
July | 2.64 | 0.73 |
August | 1.61 | 0.75 |
September | 1.18 | 0.71 |
October | 0.99 | 0.43 |
November | 0.64 | 0.16 |
December | 0.50 | 0.00 |
Annual Sum or Average | 12.45 | 0.53 |
Minimum of Months | 0.11 | 0.00 |
Maximum of Months | 2.64 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.41 | 0.00 |
February | 1.10 | 0.00 |
March | 0.22 | 0.00 |
April | 0.00 | 0.00 |
May | 0.34 | 2.45 |
June | 0.49 | 3.30 |
July | 1.26 | 3.08 |
August | 0.80 | 2.73 |
September | 0.99 | 3.11 |
October | 0.17 | 1.65 |
November | 0.36 | 0.00 |
December | 1.35 | 0.00 |
Annual Sum or Average | 9.48 | 1.25 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.41 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.70 | 0.00 |
February | 0.54 | 0.00 |
March | 0.22 | 0.00 |
April | 0.00 | 0.00 |
May | 0.34 | 1.22 |
June | 0.40 | 1.42 |
July | 1.15 | 1.53 |
August | 0.64 | 1.29 |
September | 0.79 | 1.53 |
October | 0.08 | 0.00 |
November | 0.28 | 0.00 |
December | 0.93 | 0.00 |
Annual Sum or Average | 7.08 | 0.68 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.70 | 1.53 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.70 | 0.00 |
February | 0.60 | 0.00 |
March | 0.27 | 0.00 |
April | 0.00 | 0.00 |
May | 0.26 | 1.09 |
June | 0.40 | 1.42 |
July | 1.15 | 1.53 |
August | 0.69 | 1.32 |
September | 0.88 | 1.55 |
October | 0.08 | 0.00 |
November | 0.28 | 0.00 |
December | 0.93 | 0.00 |
Annual Sum or Average | 7.25 | 0.67 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.70 | 1.55 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.14 | 0.00 |
February | 0.96 | 0.00 |
March | 0.35 | 0.00 |
April | 0.04 | 0.00 |
May | 0.32 | 0.90 |
June | 0.40 | 1.42 |
July | 1.01 | 1.65 |
August | 0.61 | 1.50 |
September | 0.82 | 1.65 |
October | 0.08 | 0.00 |
November | 0.41 | 0.00 |
December | 1.37 | 0.00 |
Annual Sum or Average | 8.50 | 0.56 |
Minimum of Months | 0.04 | 0.00 |
Maximum of Months | 2.14 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 4.35 | 0.00 |
February | 3.64 | 0.00 |
March | 2.91 | 0.00 |
April | 1.72 | 0.00 |
May | 1.00 | 0.28 |
June | 0.26 | 1.13 |
July | 0.93 | 1.65 |
August | 0.64 | 1.29 |
September | 0.86 | 1.57 |
October | 0.33 | 0.00 |
November | 2.33 | 0.00 |
December | 3.76 | 0.00 |
Annual Sum or Average | 22.73 | 0.19 |
Minimum of Months | 0.26 | 0.00 |
Maximum of Months | 4.35 | 1.65 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.518382E+10 | 0.456829E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.466700E+10 | 0.250186E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.516521E+10 | 0.199391E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.502635E+10 | 0.692970E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.591849E+10 | 0.420664E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.814707E+10 | 0.140850E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.116348E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.103022E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.766542E+10 | 0.589304E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.540264E+10 | 0.237662E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.497810E+10 | 0.132963E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.517643E+10 | 0.322308E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.792676E+11 | 0.150411E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.466700E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.116348E+11 | 0.456829E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.213493E+10 | 0.171652E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.192050E+10 | 0.901128E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.214562E+10 | 0.640101E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.217688E+10 | 0.200118E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.281781E+10 | 0.125087E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.414861E+10 | 29328534.06 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.577806E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.516982E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.379126E+10 | 0.148236E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.247641E+10 | 0.678161E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.209375E+10 | 0.443639E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.210323E+10 | 0.116732E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.367569E+11 | 0.527948E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.192050E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.577806E+10 | 0.171652E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.214490E+10 | 0.198621E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.193651E+10 | 0.110843E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.218140E+10 | 0.871660E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.208717E+10 | 0.317827E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.242522E+10 | 0.202512E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.329236E+10 | 68309220.64 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.450577E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.410347E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.300260E+10 | 0.348236E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.223344E+10 | 0.136293E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.207448E+10 | 0.619919E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.212825E+10 | 0.142825E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.321156E+11 | 0.671277E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.193651E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.450577E+10 | 0.198621E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.215364E+10 | 0.204152E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.194180E+10 | 0.115024E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.218766E+10 | 0.919236E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.208994E+10 | 0.348717E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.241857E+10 | 0.221932E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.327990E+10 | 79169178.87 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.450026E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.409510E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.299549E+10 | 0.412404E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.222970E+10 | 0.155319E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.207972E+10 | 0.661705E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.213402E+10 | 0.147828E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.321058E+11 | 0.702610E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.194180E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.450026E+10 | 0.204152E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.216926E+10 | 0.209506E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.195440E+10 | 0.119232E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.220163E+10 | 0.964233E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.210064E+10 | 0.378221E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.241922E+10 | 0.240531E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.326603E+10 | 91380916.23 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.447982E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.407719E+10 | 701712.21 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.298935E+10 | 0.466725E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.223508E+10 | 0.171361E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.209251E+10 | 0.698507E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.214752E+10 | 0.152668E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.321327E+11 | 0.732279E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.195440E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.447982E+10 | 0.209506E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.358053E+10 | 0.400208E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.321532E+10 | 0.229159E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.362500E+10 | 0.186814E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.344841E+10 | 0.754049E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.401786E+10 | 0.478702E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.570445E+10 | 0.205990E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.806697E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.727111E+10 | 19381125.35 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.513472E+10 | 0.101790E+10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.367574E+10 | 0.355147E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.343896E+10 | 0.137636E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.353181E+10 | 0.292746E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.547109E+11 | 0.141779E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.321532E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.806697E+10 | 0.400208E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.204006E+10 | 0.205893E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.183361E+10 | 0.117762E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.206813E+10 | 0.960910E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.196610E+10 | 0.386439E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.225728E+10 | 0.245611E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.308310E+10 | 0.103746E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.425902E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.386856E+10 | 9613046.96 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.279626E+10 | 0.510919E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.208449E+10 | 0.178712E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.196186E+10 | 0.703969E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.201408E+10 | 0.150491E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.302325E+11 | 0.727953E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.183361E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.425902E+10 | 0.205893E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.203831E+10 | 0.206799E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.183206E+10 | 0.118783E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.206621E+10 | 0.974923E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.196379E+10 | 0.399199E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.224940E+10 | 0.253454E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.306349E+10 | 0.111555E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.423390E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.384683E+10 | 12479523.74 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.278358E+10 | 0.536071E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.207964E+10 | 0.185321E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.196005E+10 | 0.715498E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.201249E+10 | 0.151614E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.301297E+11 | 0.736637E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.183206E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.423390E+10 | 0.206799E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.206078E+10 | 0.212577E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.185062E+10 | 0.123706E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.208639E+10 | 0.103580E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.198070E+10 | 0.446870E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.225346E+10 | 0.282689E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.304131E+10 | 0.139892E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.420843E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.382802E+10 | 22162652.38 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.277967E+10 | 0.618023E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.209133E+10 | 0.207413E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.197855E+10 | 0.757960E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.203276E+10 | 0.156923E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.301920E+11 | 0.774080E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.185062E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.420843E+10 | 0.212577E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.229540E+10 | 0.266221E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.203532E+10 | 0.158885E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.227892E+10 | 0.138212E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.214236E+10 | 0.652696E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.240229E+10 | 0.410945E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.317327E+10 | 0.280898E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.440158E+10 | 1791702.23 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.400739E+10 | 81630423.54 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.293179E+10 | 0.968174E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.224828E+10 | 0.292555E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.215041E+10 | 0.964689E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.223219E+10 | 0.194240E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.322992E+11 | 0.100297E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.203532E+10 | 1791702.23 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.440158E+10 | 0.266221E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.518382E+10 | 0.00 | 0.362037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.466700E+10 | 1565.58 | 0.198272E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.516521E+10 | 0.00 | 0.158018E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.499444E+10 | 99751617.51 | 0.549179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.514808E+10 | 0.244347E+10 | 0.333376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.499396E+10 | 0.995877E+10 | 0.111624E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.515736E+10 | 0.200760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.514715E+10 | 0.159774E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.500417E+10 | 0.840698E+10 | 0.467024E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.514723E+10 | 0.822607E+09 | 0.188347E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.497810E+10 | 4803.00 | 0.105373E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.517643E+10 | 0.00 | 0.255429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.607629E+11 | 0.577851E+11 | 0.119201E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.466700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.518382E+10 | 0.200760E+11 | 0.362037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.213493E+10 | 4333.91 | 0.137321E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.192002E+10 | 1446812.90 | 0.720902E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.214560E+10 | 59246.41 | 0.512081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.214463E+10 | 0.115890E+09 | 0.160095E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.236051E+10 | 0.163089E+10 | 0.100070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.245182E+10 | 0.588192E+10 | 23462827.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.247249E+10 | 0.111036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.251308E+10 | 0.894131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.241631E+10 | 0.470657E+10 | 0.118589E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.232944E+10 | 0.511110E+09 | 0.542529E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.208956E+10 | 16613291.15 | 0.354912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.210323E+10 | 0.00 | 0.933857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.270816E+11 | 0.329094E+11 | 0.422359E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.192002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.251308E+10 | 0.111036E+11 | 0.137321E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.214490E+10 | 0.00 | 0.158897E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.193651E+10 | 691.58 | 0.886748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.218140E+10 | 0.00 | 0.697328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207448E+10 | 41950851.24 | 0.254262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.215959E+10 | 0.886325E+09 | 0.162010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.210639E+10 | 0.393884E+10 | 54647376.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.212767E+10 | 0.776110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.218086E+10 | 0.628043E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.207448E+10 | 0.309933E+10 | 0.278589E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.213831E+10 | 0.322703E+09 | 0.109035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.207448E+10 | 1116.09 | 0.495935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212825E+10 | 0.00 | 0.114260E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.253273E+11 | 0.223307E+11 | 0.537021E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.193651E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.218140E+10 | 0.776110E+10 | 0.158897E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.215364E+10 | 0.00 | 0.163322E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.194180E+10 | 666.84 | 0.920189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.218766E+10 | 0.00 | 0.735389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207972E+10 | 33672616.96 | 0.278974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.216504E+10 | 0.843213E+09 | 0.177546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.211171E+10 | 0.387261E+10 | 63335343.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.213304E+10 | 0.771755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.218637E+10 | 0.622728E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.207972E+10 | 0.305381E+10 | 0.329923E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.214371E+10 | 0.290752E+09 | 0.124255E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.207972E+10 | 742.13 | 0.529364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.213402E+10 | 0.00 | 0.118262E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.253962E+11 | 0.220389E+11 | 0.562088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.194180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.218766E+10 | 0.771755E+10 | 0.163322E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.216926E+10 | 0.00 | 0.167605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.195440E+10 | 846.98 | 0.953855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.220163E+10 | 0.00 | 0.771386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.209251E+10 | 26675001.37 | 0.302577E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217835E+10 | 0.798147E+09 | 0.192425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.212470E+10 | 0.377219E+10 | 73104732.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.214616E+10 | 0.758687E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.219982E+10 | 0.610717E+10 | 561369.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.209251E+10 | 0.298270E+10 | 0.373380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.215689E+10 | 0.263555E+09 | 0.137089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.209251E+10 | 0.00 | 0.558805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.214752E+10 | 0.00 | 0.122134E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.255563E+11 | 0.215373E+11 | 0.585823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.195440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.220163E+10 | 0.758687E+10 | 0.167605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.358053E+10 | 0.00 | 0.317165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.321532E+10 | 305.42 | 0.181608E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.362500E+10 | 0.00 | 0.148050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.343795E+10 | 32185229.83 | 0.597584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.358119E+10 | 0.135550E+10 | 0.379371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.349524E+10 | 0.684806E+10 | 0.163247E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.352389E+10 | 0.138464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.361939E+10 | 0.111366E+11 | 15359541.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.343795E+10 | 0.530081E+10 | 0.806688E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.354299E+10 | 0.419660E+09 | 0.281454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.343896E+10 | 0.00 | 0.109077E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.353181E+10 | 0.00 | 0.232001E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.420302E+11 | 0.389393E+11 | 0.112359E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.321532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.362500E+10 | 0.138464E+11 | 0.317165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.204006E+10 | 0.00 | 0.164714E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.183361E+10 | 0.00 | 0.942099E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206813E+10 | 0.00 | 0.768728E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.196142E+10 | 15242124.94 | 0.309151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.204315E+10 | 0.702647E+09 | 0.196489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199411E+10 | 0.356442E+10 | 82996656.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.201045E+10 | 0.723065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.206494E+10 | 0.580362E+10 | 7690437.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.196142E+10 | 0.275218E+10 | 0.408735E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.202135E+10 | 0.211196E+09 | 0.142970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196186E+10 | 0.00 | 0.563175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.201408E+10 | 0.00 | 0.120393E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.239746E+11 | 0.202800E+11 | 0.582363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.183361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206813E+10 | 0.723065E+10 | 0.164714E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.203831E+10 | 0.00 | 0.165439E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.183206E+10 | 0.00 | 0.950265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206621E+10 | 0.00 | 0.779938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.195959E+10 | 13633272.78 | 0.319359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.204124E+10 | 0.681767E+09 | 0.202763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199225E+10 | 0.350106E+10 | 89244179.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.200858E+10 | 0.714681E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.206302E+10 | 0.573249E+10 | 9983618.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.195959E+10 | 0.271304E+10 | 0.428857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.201947E+10 | 0.200967E+09 | 0.148257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196005E+10 | 0.00 | 0.572399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.201249E+10 | 0.00 | 0.121291E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.239529E+11 | 0.199898E+11 | 0.589310E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.183206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206621E+10 | 0.714681E+10 | 0.165439E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.206078E+10 | 0.00 | 0.170062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.185062E+10 | 0.00 | 0.989646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208639E+10 | 0.00 | 0.828637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.197777E+10 | 9471070.41 | 0.357496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.206018E+10 | 0.629559E+09 | 0.226151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.201074E+10 | 0.335317E+10 | 0.111914E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.202722E+10 | 0.697918E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.208216E+10 | 0.558972E+10 | 17730121.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.197777E+10 | 0.263074E+10 | 0.494419E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.203821E+10 | 0.176719E+09 | 0.165931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.197855E+10 | 0.00 | 0.606368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.203276E+10 | 0.00 | 0.125539E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.241832E+11 | 0.193686E+11 | 0.619264E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.185062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.208639E+10 | 0.697918E+10 | 0.170062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.229540E+10 | 0.00 | 0.212977E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.203532E+10 | 0.00 | 0.127108E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.227892E+10 | 0.00 | 0.110570E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.214171E+10 | 2080559.60 | 0.522157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.223227E+10 | 0.545212E+09 | 0.328756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.217481E+10 | 0.320350E+10 | 0.224718E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.219263E+10 | 0.697604E+10 | 1433361.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.225205E+10 | 0.554480E+10 | 65304338.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.213915E+10 | 0.256381E+10 | 0.774539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.220456E+10 | 0.143936E+09 | 0.234044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.215041E+10 | 0.00 | 0.771752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.223219E+10 | 0.00 | 0.155392E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.263294E+11 | 0.189794E+11 | 0.802377E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.203532E+10 | 0.00 | 1433361.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.229540E+10 | 0.697604E+10 | 0.212977E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.518382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456829E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.466700E+10 | 0.00 | 0.00 | 0.00 | 508.84 | 0.00 | 0.250186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.516521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199391E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.499444E+10 | 0.00 | 0.00 | 0.00 | 31901675.70 | 0.00 | 0.692970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.514808E+10 | 0.00 | 0.00 | 0.00 | 0.770410E+09 | 0.00 | 0.420664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.499396E+10 | 0.00 | 0.00 | 0.00 | 0.315312E+10 | 0.00 | 0.140850E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.515736E+10 | 0.00 | 0.00 | 0.00 | 0.647748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.514715E+10 | 0.00 | 0.00 | 0.00 | 0.515506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.500417E+10 | 0.00 | 0.00 | 0.00 | 0.266125E+10 | 0.00 | 0.589304E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.514723E+10 | 0.00 | 0.00 | 0.00 | 0.255414E+09 | 0.00 | 0.237662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.497810E+10 | 0.00 | 0.00 | 0.00 | 1561.05 | 0.00 | 0.132963E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.517643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322308E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.607629E+11 | 0.00 | 0.00 | 0.00 | 0.185046E+11 | 0.00 | 0.150411E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.466700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.518382E+10 | 0.00 | 0.00 | 0.00 | 0.647748E+10 | 0.00 | 0.456829E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.213493E+10 | 0.00 | 0.00 | 0.00 | 1430.72 | 0.00 | 0.171652E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.192002E+10 | 0.00 | 0.00 | 0.00 | 474665.43 | 0.00 | 0.901128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.214560E+10 | 0.00 | 0.00 | 0.00 | 19547.53 | 0.00 | 0.640101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.214463E+10 | 0.00 | 0.00 | 0.00 | 32253627.38 | 0.00 | 0.200118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.236051E+10 | 0.00 | 0.00 | 0.00 | 0.457292E+09 | 0.00 | 0.125087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.245182E+10 | 0.00 | 0.00 | 0.00 | 0.169679E+10 | 0.00 | 29328534.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.247249E+10 | 0.00 | 0.00 | 0.00 | 0.330557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.251308E+10 | 0.00 | 0.00 | 0.00 | 0.265675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.241631E+10 | 0.00 | 0.00 | 0.00 | 0.137494E+10 | 0.00 | 0.148236E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.232944E+10 | 0.00 | 0.00 | 0.00 | 0.146962E+09 | 0.00 | 0.678161E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.208956E+10 | 0.00 | 0.00 | 0.00 | 4184917.53 | 0.00 | 0.443639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.210323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116732E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.270816E+11 | 0.00 | 0.00 | 0.00 | 0.967524E+10 | 0.00 | 0.527948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.192002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.251308E+10 | 0.00 | 0.00 | 0.00 | 0.330557E+10 | 0.00 | 0.171652E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.214490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198621E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.193651E+10 | 0.00 | 0.00 | 0.00 | 211.94 | 0.00 | 0.110843E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.218140E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.871660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207448E+10 | 0.00 | 0.00 | 0.00 | 12687261.16 | 0.00 | 0.317827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.215959E+10 | 0.00 | 0.00 | 0.00 | 0.265636E+09 | 0.00 | 0.202512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.210639E+10 | 0.00 | 0.00 | 0.00 | 0.118597E+10 | 0.00 | 68309220.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.212767E+10 | 0.00 | 0.00 | 0.00 | 0.237809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.218086E+10 | 0.00 | 0.00 | 0.00 | 0.192261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.207448E+10 | 0.00 | 0.00 | 0.00 | 0.928120E+09 | 0.00 | 0.348236E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.213831E+10 | 0.00 | 0.00 | 0.00 | 95131702.55 | 0.00 | 0.136293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.207448E+10 | 0.00 | 0.00 | 0.00 | 342.03 | 0.00 | 0.619919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212825E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.253273E+11 | 0.00 | 0.00 | 0.00 | 0.678825E+10 | 0.00 | 0.671277E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.193651E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.218140E+10 | 0.00 | 0.00 | 0.00 | 0.237809E+10 | 0.00 | 0.198621E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.215364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204152E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.194180E+10 | 0.00 | 0.00 | 0.00 | 204.36 | 0.00 | 0.115024E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.218766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207972E+10 | 0.00 | 0.00 | 0.00 | 10223751.52 | 0.00 | 0.348717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.216504E+10 | 0.00 | 0.00 | 0.00 | 0.253533E+09 | 0.00 | 0.221932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.211171E+10 | 0.00 | 0.00 | 0.00 | 0.116818E+10 | 0.00 | 79169178.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.213304E+10 | 0.00 | 0.00 | 0.00 | 0.236721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.218637E+10 | 0.00 | 0.00 | 0.00 | 0.190873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.207972E+10 | 0.00 | 0.00 | 0.00 | 0.915774E+09 | 0.00 | 0.412404E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.214371E+10 | 0.00 | 0.00 | 0.00 | 85992217.16 | 0.00 | 0.155319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.207972E+10 | 0.00 | 0.00 | 0.00 | 227.43 | 0.00 | 0.661705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.213402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147828E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.253962E+11 | 0.00 | 0.00 | 0.00 | 0.670965E+10 | 0.00 | 0.702610E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.194180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.218766E+10 | 0.00 | 0.00 | 0.00 | 0.236721E+10 | 0.00 | 0.204152E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.216926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209506E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.195440E+10 | 0.00 | 0.00 | 0.00 | 259.56 | 0.00 | 0.119232E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.220163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.964233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.209251E+10 | 0.00 | 0.00 | 0.00 | 8130464.05 | 0.00 | 0.378221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217835E+10 | 0.00 | 0.00 | 0.00 | 0.240868E+09 | 0.00 | 0.240531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.212470E+10 | 0.00 | 0.00 | 0.00 | 0.114133E+10 | 0.00 | 91380916.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.214616E+10 | 0.00 | 0.00 | 0.00 | 0.233366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.219982E+10 | 0.00 | 0.00 | 0.00 | 0.187737E+10 | 0.00 | 701712.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.209251E+10 | 0.00 | 0.00 | 0.00 | 0.896846E+09 | 0.00 | 0.466725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.215689E+10 | 0.00 | 0.00 | 0.00 | 78190421.23 | 0.00 | 0.171361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.209251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.698507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.214752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.255563E+11 | 0.00 | 0.00 | 0.00 | 0.657640E+10 | 0.00 | 0.732279E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.195440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.220163E+10 | 0.00 | 0.00 | 0.00 | 0.233366E+10 | 0.00 | 0.209506E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.358053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.321532E+10 | 0.00 | 0.00 | 0.00 | 99.27 | 0.00 | 0.229159E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.362500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.343795E+10 | 0.00 | 0.00 | 0.00 | 10466707.67 | 0.00 | 0.754049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.358119E+10 | 0.00 | 0.00 | 0.00 | 0.436667E+09 | 0.00 | 0.478702E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.349524E+10 | 0.00 | 0.00 | 0.00 | 0.220921E+10 | 0.00 | 0.205990E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.352389E+10 | 0.00 | 0.00 | 0.00 | 0.454308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.361939E+10 | 0.00 | 0.00 | 0.00 | 0.365172E+10 | 0.00 | 19381125.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.343795E+10 | 0.00 | 0.00 | 0.00 | 0.169677E+10 | 0.00 | 0.101790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.354299E+10 | 0.00 | 0.00 | 0.00 | 0.132742E+09 | 0.00 | 0.355147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.343896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137636E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.353181E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.292746E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.420302E+11 | 0.00 | 0.00 | 0.00 | 0.126807E+11 | 0.00 | 0.141779E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.321532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.362500E+10 | 0.00 | 0.00 | 0.00 | 0.454308E+10 | 0.00 | 0.400208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.204006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205893E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.183361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117762E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.960910E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.196142E+10 | 0.00 | 0.00 | 0.00 | 4683223.12 | 0.00 | 0.386439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.204315E+10 | 0.00 | 0.00 | 0.00 | 0.214133E+09 | 0.00 | 0.245611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199411E+10 | 0.00 | 0.00 | 0.00 | 0.108899E+10 | 0.00 | 0.103746E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.201045E+10 | 0.00 | 0.00 | 0.00 | 0.224856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.206494E+10 | 0.00 | 0.00 | 0.00 | 0.180362E+10 | 0.00 | 9613046.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.196142E+10 | 0.00 | 0.00 | 0.00 | 0.834841E+09 | 0.00 | 0.510919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.202135E+10 | 0.00 | 0.00 | 0.00 | 63136304.33 | 0.00 | 0.178712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.703969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150491E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.239746E+11 | 0.00 | 0.00 | 0.00 | 0.625796E+10 | 0.00 | 0.727953E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.183361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206813E+10 | 0.00 | 0.00 | 0.00 | 0.224856E+10 | 0.00 | 0.205893E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.203831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.183206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.974923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.195959E+10 | 0.00 | 0.00 | 0.00 | 4195849.44 | 0.00 | 0.399199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.204124E+10 | 0.00 | 0.00 | 0.00 | 0.208153E+09 | 0.00 | 0.253454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.199225E+10 | 0.00 | 0.00 | 0.00 | 0.107124E+10 | 0.00 | 0.111555E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.200858E+10 | 0.00 | 0.00 | 0.00 | 0.222532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.206302E+10 | 0.00 | 0.00 | 0.00 | 0.178381E+10 | 0.00 | 12479523.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.195959E+10 | 0.00 | 0.00 | 0.00 | 0.823989E+09 | 0.00 | 0.536071E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.201947E+10 | 0.00 | 0.00 | 0.00 | 60165635.40 | 0.00 | 0.185321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196005E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.715498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.201249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151614E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.239529E+11 | 0.00 | 0.00 | 0.00 | 0.617687E+10 | 0.00 | 0.736637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.183206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206621E+10 | 0.00 | 0.00 | 0.00 | 0.222532E+10 | 0.00 | 0.206799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.206078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.185062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123706E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.197777E+10 | 0.00 | 0.00 | 0.00 | 2930083.48 | 0.00 | 0.446870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.206018E+10 | 0.00 | 0.00 | 0.00 | 0.193273E+09 | 0.00 | 0.282689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.201074E+10 | 0.00 | 0.00 | 0.00 | 0.103057E+10 | 0.00 | 0.139892E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.202722E+10 | 0.00 | 0.00 | 0.00 | 0.218121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.208216E+10 | 0.00 | 0.00 | 0.00 | 0.174586E+10 | 0.00 | 22162652.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.197777E+10 | 0.00 | 0.00 | 0.00 | 0.801893E+09 | 0.00 | 0.618023E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.203821E+10 | 0.00 | 0.00 | 0.00 | 53123609.67 | 0.00 | 0.207413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.197855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.757960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.203276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.241832E+11 | 0.00 | 0.00 | 0.00 | 0.600886E+10 | 0.00 | 0.774080E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.185062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.208639E+10 | 0.00 | 0.00 | 0.00 | 0.218121E+10 | 0.00 | 0.212577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.229540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266221E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.203532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158885E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.227892E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138212E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.214171E+10 | 0.00 | 0.00 | 0.00 | 654313.59 | 0.00 | 0.652696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.223227E+10 | 0.00 | 0.00 | 0.00 | 0.170017E+09 | 0.00 | 0.410945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.217481E+10 | 0.00 | 0.00 | 0.00 | 0.998468E+09 | 0.00 | 0.280898E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.219263E+10 | 0.00 | 0.00 | 0.00 | 0.220895E+10 | 0.00 | 1791702.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.225205E+10 | 0.00 | 0.00 | 0.00 | 0.175533E+10 | 0.00 | 81630423.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.213915E+10 | 0.00 | 0.00 | 0.00 | 0.792632E+09 | 0.00 | 0.968174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.220456E+10 | 0.00 | 0.00 | 0.00 | 43720076.05 | 0.00 | 0.292555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.215041E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.964689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.223219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194240E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.263294E+11 | 0.00 | 0.00 | 0.00 | 0.596977E+10 | 0.00 | 0.100297E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.203532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1791702.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.229540E+10 | 0.00 | 0.00 | 0.00 | 0.220895E+10 | 0.00 | 0.266221E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.470523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235710E+11 | 0.00 | 0.00 | 0.68 |
February | 0.667839E+10 | 0.00 | 0.00 | 64552.33 | 0.00 | 0.128367E+11 | 0.104447E+09 | 0.00 | 0.68 |
March | 0.924434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.954313E+10 | 0.00 | 0.00 | 0.68 |
April | 0.802633E+10 | 0.00 | 0.00 | 1825020.35 | 0.00 | 0.349317E+10 | 0.175021E+10 | 0.00 | 0.77 |
May | 0.585084E+10 | 66819998.29 | 0.00 | 13820627.68 | 1986241.27 | 0.193291E+10 | 0.474767E+10 | 0.00 | 1.06 |
June | 0.121410E+10 | 0.773502E+09 | 0.00 | 27628097.68 | 0.00 | 11894725.51 | 0.780429E+10 | 0.00 | 1.40 |
July | 0.127298E+09 | 0.197875E+10 | 0.00 | 35535094.65 | 1960584.24 | 0.00 | 0.562341E+10 | 0.00 | 1.37 |
August | 0.562641E+09 | 0.139323E+10 | 0.00 | 35385184.42 | 491280.02 | 0.00 | 0.741904E+10 | 0.00 | 1.48 |
September | 0.306951E+10 | 0.715378E+09 | 0.00 | 22303878.68 | 0.00 | 86488506.30 | 0.766900E+10 | 0.00 | 1.28 |
October | 0.779176E+10 | 5894126.30 | 0.00 | 7196067.69 | 0.00 | 0.811326E+09 | 0.561529E+10 | 0.00 | 0.93 |
November | 0.999652E+10 | 0.00 | 0.00 | 426929.29 | 0.00 | 0.604123E+10 | 0.554255E+09 | 0.00 | 0.68 |
December | 0.752014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163431E+11 | 0.00 | 0.00 | 0.68 |
Annual Sum or Average | 0.647871E+11 | 0.493357E+10 | 0.00 | 0.144185E+09 | 4438105.53 | 0.746708E+11 | 0.412876E+11 | 0.00 | 0.98 |
Minimum of Months | 0.127298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.68 |
Maximum of Months | 0.999652E+10 | 0.197875E+10 | 0.00 | 35535094.65 | 1986241.27 | 0.235710E+11 | 0.780429E+10 | 0.00 | 1.48 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.145966E+10 | 0.00 | 0.00 | 338.53 | 0.00 | 0.877936E+10 | 265764.35 | 0.00 | 0.50 |
February | 0.216099E+10 | 0.00 | 0.00 | 151329.75 | 0.00 | 0.478422E+10 | 0.151932E+09 | 0.00 | 0.51 |
March | 0.329177E+10 | 0.00 | 0.00 | 7598.07 | 0.00 | 0.337814E+10 | 5467590.19 | 0.00 | 0.51 |
April | 0.281637E+10 | 0.00 | 0.00 | 1434492.45 | 0.00 | 0.112895E+10 | 0.127793E+10 | 0.00 | 0.66 |
May | 0.207238E+10 | 33793664.37 | 0.00 | 5269941.92 | 322034.37 | 0.683283E+09 | 0.268181E+10 | 0.00 | 0.98 |
June | 0.378135E+09 | 0.381627E+09 | 0.00 | 9368712.70 | 0.00 | 0.00 | 0.404757E+10 | 0.00 | 1.33 |
July | 33844747.51 | 0.954158E+09 | 0.00 | 9429850.65 | 207550.49 | 0.00 | 0.250949E+10 | 0.00 | 1.19 |
August | 0.182193E+09 | 0.671788E+09 | 0.00 | 11144767.44 | 367502.73 | 0.00 | 0.360087E+10 | 0.00 | 1.36 |
September | 0.103433E+10 | 0.344119E+09 | 0.00 | 8311483.62 | 0.00 | 6472521.93 | 0.412420E+10 | 0.00 | 1.22 |
October | 0.259124E+10 | 2982833.30 | 0.00 | 4584172.31 | 0.00 | 0.308453E+09 | 0.340628E+10 | 0.00 | 0.88 |
November | 0.332249E+10 | 0.00 | 0.00 | 501415.87 | 0.00 | 0.238399E+10 | 0.455108E+09 | 0.00 | 0.53 |
December | 0.239591E+10 | 0.00 | 0.00 | 5314.15 | 0.00 | 0.605379E+10 | 4525024.26 | 0.00 | 0.50 |
Annual Sum or Average | 0.217393E+11 | 0.238847E+10 | 0.00 | 50209417.46 | 897087.60 | 0.275067E+11 | 0.222655E+11 | 0.00 | 0.85 |
Minimum of Months | 33844747.51 | 0.00 | 0.00 | 338.53 | 0.00 | 0.00 | 265764.35 | 0.00 | 0.50 |
Maximum of Months | 0.332249E+10 | 0.954158E+09 | 0.00 | 11144767.44 | 367502.73 | 0.877936E+10 | 0.412420E+10 | 0.00 | 1.36 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.558229E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102884E+11 | 0.00 | 0.00 | 0.53 |
February | 0.142353E+10 | 0.00 | 0.00 | 14568.07 | 0.00 | 0.606013E+10 | 25584011.25 | 0.00 | 0.53 |
March | 0.230930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.486014E+10 | 0.00 | 0.00 | 0.54 |
April | 0.265614E+10 | 0.00 | 0.00 | 321826.03 | 0.00 | 0.181827E+10 | 0.373743E+09 | 0.00 | 0.60 |
May | 0.215908E+10 | 31153023.06 | 0.00 | 1486566.35 | 2226257.87 | 0.111548E+10 | 0.116696E+10 | 0.00 | 0.77 |
June | 0.747562E+09 | 0.351132E+09 | 0.00 | 3640970.35 | 7084813.00 | 5154153.56 | 0.226694E+10 | 0.00 | 1.01 |
July | 0.170209E+09 | 0.836068E+09 | 0.00 | 3914631.54 | 35332247.83 | 0.00 | 0.152560E+10 | 0.00 | 0.95 |
August | 0.451856E+09 | 0.615307E+09 | 0.00 | 4724639.96 | 20179686.75 | 0.00 | 0.220030E+10 | 0.00 | 1.08 |
September | 0.142623E+10 | 0.291903E+09 | 0.00 | 3329135.52 | 15996054.08 | 0.214542E+09 | 0.208415E+10 | 0.00 | 0.94 |
October | 0.303639E+10 | 3134318.67 | 0.00 | 1410958.55 | 0.00 | 0.673170E+09 | 0.128091E+10 | 0.00 | 0.71 |
November | 0.281757E+10 | 0.00 | 0.00 | 18687.58 | 0.00 | 0.333365E+10 | 41353741.20 | 0.00 | 0.53 |
December | 0.113820E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.789616E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.188943E+11 | 0.212870E+10 | 0.00 | 18861983.94 | 80819059.52 | 0.362651E+11 | 0.109655E+11 | 0.00 | 0.73 |
Minimum of Months | 0.170209E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.303639E+10 | 0.836068E+09 | 0.00 | 4724639.96 | 35332247.83 | 0.102884E+11 | 0.226694E+10 | 0.00 | 1.08 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.369746E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104769E+11 | 0.00 | 0.00 | 0.53 |
February | 0.114237E+10 | 0.00 | 0.00 | 6482.48 | 0.00 | 0.633743E+10 | 16848834.60 | 0.00 | 0.53 |
March | 0.203071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.513441E+10 | 0.00 | 0.00 | 0.54 |
April | 0.243435E+10 | 0.00 | 0.00 | 251359.37 | 0.00 | 0.204029E+10 | 0.314587E+09 | 0.00 | 0.59 |
May | 0.206409E+10 | 31139123.17 | 0.00 | 1319545.38 | 2553951.23 | 0.122950E+10 | 0.106429E+10 | 0.00 | 0.76 |
June | 0.773778E+09 | 0.350521E+09 | 0.00 | 3452407.30 | 7094852.16 | 10394597.70 | 0.217709E+10 | 0.00 | 1.00 |
July | 0.174176E+09 | 0.836102E+09 | 0.00 | 3840244.88 | 35468390.38 | 0.00 | 0.150807E+10 | 0.00 | 0.95 |
August | 0.462666E+09 | 0.615265E+09 | 0.00 | 4618529.43 | 20227495.63 | 0.00 | 0.216628E+10 | 0.00 | 1.08 |
September | 0.140423E+10 | 0.291517E+09 | 0.00 | 3170408.23 | 16024260.27 | 0.259392E+09 | 0.200745E+10 | 0.00 | 0.93 |
October | 0.296301E+10 | 3136066.93 | 0.00 | 1175063.05 | 0.00 | 0.850354E+09 | 0.108013E+10 | 0.00 | 0.70 |
November | 0.248918E+10 | 0.00 | 0.00 | 8918.79 | 0.00 | 0.365572E+10 | 22609448.96 | 0.00 | 0.53 |
December | 0.892454E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.814195E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.172007E+11 | 0.212768E+10 | 0.00 | 17842958.89 | 81368949.67 | 0.381364E+11 | 0.103574E+11 | 0.00 | 0.72 |
Minimum of Months | 0.174176E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.296301E+10 | 0.836102E+09 | 0.00 | 4618529.43 | 35468390.38 | 0.104769E+11 | 0.217709E+10 | 0.00 | 1.08 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.248103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105985E+11 | 0.00 | 0.00 | 0.53 |
February | 0.933109E+09 | 0.00 | 0.00 | 2178.75 | 0.00 | 0.654658E+10 | 9422120.60 | 0.00 | 0.53 |
March | 0.177601E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538680E+10 | 0.00 | 0.00 | 0.54 |
April | 0.222749E+10 | 0.00 | 0.00 | 197062.70 | 0.00 | 0.226119E+10 | 0.258631E+09 | 0.00 | 0.58 |
May | 0.197511E+10 | 31119756.78 | 0.00 | 1147790.44 | 2871894.61 | 0.135581E+10 | 0.946202E+09 | 0.00 | 0.74 |
June | 0.831289E+09 | 0.349505E+09 | 0.00 | 3166437.61 | 7126852.14 | 16184566.93 | 0.203062E+10 | 0.00 | 0.99 |
July | 0.193646E+09 | 0.835242E+09 | 0.00 | 3602018.79 | 35844924.06 | 0.00 | 0.145303E+10 | 0.00 | 0.95 |
August | 0.478978E+09 | 0.615160E+09 | 0.00 | 4358278.65 | 20364918.10 | 0.00 | 0.209781E+10 | 0.00 | 1.07 |
September | 0.145882E+10 | 0.290814E+09 | 0.00 | 2948333.43 | 16114168.88 | 0.284608E+09 | 0.186175E+10 | 0.00 | 0.92 |
October | 0.290727E+10 | 3140324.52 | 0.00 | 1005661.30 | 0.00 | 0.100037E+10 | 0.908071E+09 | 0.00 | 0.69 |
November | 0.221852E+10 | 0.00 | 0.00 | 2376.14 | 0.00 | 0.391989E+10 | 13028978.52 | 0.00 | 0.53 |
December | 0.705347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.832888E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.159537E+11 | 0.212498E+10 | 0.00 | 16430137.79 | 82322757.78 | 0.396988E+11 | 0.957856E+10 | 0.00 | 0.72 |
Minimum of Months | 0.193646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.290727E+10 | 0.835242E+09 | 0.00 | 4358278.65 | 35844924.06 | 0.105985E+11 | 0.209781E+10 | 0.00 | 1.07 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 92980491.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198114E+11 | 0.00 | 0.00 | 0.49 |
February | 0.103483E+10 | 0.00 | 0.00 | 1068.80 | 0.00 | 0.126427E+11 | 8624373.31 | 0.00 | 0.49 |
March | 0.266602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103681E+11 | 0.00 | 0.00 | 0.50 |
April | 0.385778E+10 | 0.00 | 0.00 | 242229.36 | 0.00 | 0.422470E+10 | 0.393226E+09 | 0.00 | 0.52 |
May | 0.341355E+10 | 47101435.07 | 0.00 | 1872026.83 | 5164034.17 | 0.264828E+10 | 0.146405E+10 | 0.00 | 0.66 |
June | 0.129380E+10 | 0.670484E+09 | 0.00 | 5440874.16 | 394930.38 | 42352272.92 | 0.339343E+10 | 0.00 | 0.87 |
July | 0.239694E+09 | 0.165526E+10 | 0.00 | 5952074.61 | 26331629.52 | 0.00 | 0.227845E+10 | 0.00 | 0.83 |
August | 0.564659E+09 | 0.117886E+10 | 0.00 | 7411755.81 | 28884784.37 | 0.00 | 0.361455E+10 | 0.00 | 0.94 |
September | 0.242534E+10 | 0.535475E+09 | 0.00 | 4866207.28 | 29238906.15 | 0.556988E+09 | 0.315072E+10 | 0.00 | 0.81 |
October | 0.502465E+10 | 3825139.60 | 0.00 | 1540999.82 | 0.00 | 0.193846E+10 | 0.148119E+10 | 0.00 | 0.61 |
November | 0.340646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.776293E+10 | 0.00 | 0.00 | 0.49 |
December | 0.592273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159194E+11 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.246121E+11 | 0.409100E+10 | 0.00 | 27327236.66 | 90014284.59 | 0.759154E+11 | 0.157842E+11 | 0.00 | 0.64 |
Minimum of Months | 92980491.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.502465E+10 | 0.165526E+10 | 0.00 | 7411755.81 | 29238906.15 | 0.198114E+11 | 0.361455E+10 | 0.00 | 0.94 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 38843485.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.990500E+10 | 0.00 | 0.00 | 0.49 |
February | 0.478298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.635753E+10 | 0.00 | 0.00 | 0.49 |
March | 0.117610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.533247E+10 | 0.00 | 0.00 | 0.50 |
April | 0.181855E+10 | 0.00 | 0.00 | 107083.89 | 0.00 | 0.222675E+10 | 0.191408E+09 | 0.00 | 0.53 |
May | 0.153549E+10 | 24370577.52 | 0.00 | 892950.69 | 2717030.18 | 0.150443E+10 | 0.745389E+09 | 0.00 | 0.67 |
June | 0.652522E+09 | 0.337717E+09 | 0.00 | 2672421.65 | 205859.45 | 46124951.57 | 0.173959E+10 | 0.00 | 0.91 |
July | 0.128517E+09 | 0.833766E+09 | 0.00 | 2959582.84 | 13094687.24 | 0.00 | 0.120208E+10 | 0.00 | 0.87 |
August | 0.298574E+09 | 0.592655E+09 | 0.00 | 3705083.49 | 15693805.18 | 0.00 | 0.189832E+10 | 0.00 | 1.00 |
September | 0.116664E+10 | 0.269482E+09 | 0.00 | 2440681.36 | 14806778.19 | 0.322363E+09 | 0.166727E+10 | 0.00 | 0.85 |
October | 0.244172E+10 | 2018074.74 | 0.00 | 755352.33 | 0.00 | 0.102547E+10 | 0.784487E+09 | 0.00 | 0.62 |
November | 0.156794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401079E+10 | 0.00 | 0.00 | 0.49 |
December | 0.233966E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.801337E+10 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.115372E+11 | 0.206001E+10 | 0.00 | 13533156.25 | 46518160.24 | 0.387443E+11 | 0.822854E+10 | 0.00 | 0.66 |
Minimum of Months | 38843485.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.244172E+10 | 0.833766E+09 | 0.00 | 3705083.49 | 15693805.18 | 0.990500E+10 | 0.189832E+10 | 0.00 | 1.00 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 27487720.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.991639E+10 | 0.00 | 0.00 | 0.49 |
February | 0.456518E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.637784E+10 | 0.00 | 0.00 | 0.49 |
March | 0.110626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540188E+10 | 0.00 | 0.00 | 0.50 |
April | 0.174007E+10 | 0.00 | 0.00 | 92127.72 | 0.00 | 0.230832E+10 | 0.174367E+09 | 0.00 | 0.52 |
May | 0.151514E+10 | 24368642.42 | 0.00 | 826495.17 | 2829799.47 | 0.154207E+10 | 0.693324E+09 | 0.00 | 0.67 |
June | 0.656215E+09 | 0.337097E+09 | 0.00 | 2522511.93 | 207864.18 | 71342931.35 | 0.165984E+10 | 0.00 | 0.90 |
July | 0.133696E+09 | 0.832845E+09 | 0.00 | 2856427.09 | 13621272.50 | 0.00 | 0.117599E+10 | 0.00 | 0.86 |
August | 0.304093E+09 | 0.592675E+09 | 0.00 | 3592883.76 | 15741627.91 | 0.00 | 0.186268E+10 | 0.00 | 0.99 |
September | 0.116416E+10 | 0.268960E+09 | 0.00 | 2351483.40 | 14880032.91 | 0.338534E+09 | 0.162017E+10 | 0.00 | 0.84 |
October | 0.242836E+10 | 2017320.88 | 0.00 | 700574.47 | 0.00 | 0.105537E+10 | 0.738580E+09 | 0.00 | 0.62 |
November | 0.151847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.405702E+10 | 0.00 | 0.00 | 0.49 |
December | 0.201873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.804549E+10 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.112523E+11 | 0.205796E+10 | 0.00 | 12942503.54 | 47280596.98 | 0.391143E+11 | 0.792495E+10 | 0.00 | 0.66 |
Minimum of Months | 27487720.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.242836E+10 | 0.832845E+09 | 0.00 | 3592883.76 | 15741627.91 | 0.991639E+10 | 0.186268E+10 | 0.00 | 0.99 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 12622836.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.993126E+10 | 0.00 | 0.00 | 0.49 |
February | 0.359381E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.647106E+10 | 0.00 | 0.00 | 0.49 |
March | 0.826603E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568056E+10 | 0.00 | 0.00 | 0.50 |
April | 0.138637E+10 | 0.00 | 0.00 | 54839.91 | 0.00 | 0.267266E+10 | 0.126592E+09 | 0.00 | 0.52 |
May | 0.141757E+10 | 24349778.73 | 0.00 | 659603.58 | 3213953.50 | 0.166895E+10 | 0.575750E+09 | 0.00 | 0.65 |
June | 0.702248E+09 | 0.335697E+09 | 0.00 | 2126387.47 | 210465.01 | 0.109275E+09 | 0.144018E+10 | 0.00 | 0.87 |
July | 0.167014E+09 | 0.831717E+09 | 0.00 | 2579870.46 | 13881912.29 | 0.00 | 0.108793E+10 | 0.00 | 0.85 |
August | 0.337599E+09 | 0.592722E+09 | 0.00 | 3305879.20 | 15837200.67 | 0.00 | 0.175469E+10 | 0.00 | 0.98 |
September | 0.115233E+10 | 0.267979E+09 | 0.00 | 2119850.15 | 14990267.61 | 0.371064E+09 | 0.151876E+10 | 0.00 | 0.83 |
October | 0.230361E+10 | 2024795.10 | 0.00 | 573200.40 | 0.00 | 0.120604E+10 | 0.645244E+09 | 0.00 | 0.61 |
November | 0.122456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.434274E+10 | 0.00 | 0.00 | 0.49 |
December | 0.112236E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.813505E+10 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.100021E+11 | 0.205449E+10 | 0.00 | 11419631.17 | 48133799.08 | 0.405887E+11 | 0.714913E+10 | 0.00 | 0.65 |
Minimum of Months | 12622836.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.230361E+10 | 0.831717E+09 | 0.00 | 3305879.20 | 15837200.67 | 0.993126E+10 | 0.175469E+10 | 0.00 | 0.98 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:00
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.993144E+10 | 0.00 | 0.00 | 0.49 |
February | 0.125049E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.668749E+10 | 0.00 | 0.00 | 0.49 |
March | 45638444.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.644220E+10 | 0.00 | 0.00 | 0.50 |
April | 0.680372E+09 | 0.00 | 0.00 | 259.80 | 0.00 | 0.340898E+10 | 6045484.66 | 0.00 | 0.50 |
May | 0.101057E+10 | 24739792.00 | 0.00 | 371389.98 | 3866190.03 | 0.214625E+10 | 0.358241E+09 | 0.00 | 0.63 |
June | 0.833200E+09 | 0.336437E+09 | 0.00 | 1512198.65 | 215300.72 | 0.159475E+09 | 0.105002E+10 | 0.00 | 0.86 |
July | 0.228292E+09 | 0.832236E+09 | 0.00 | 2155161.83 | 13634011.18 | 0.00 | 0.974623E+09 | 0.00 | 0.87 |
August | 0.300215E+09 | 0.594472E+09 | 0.00 | 2731397.17 | 15506675.29 | 82039011.44 | 0.162101E+10 | 0.00 | 1.00 |
September | 0.101506E+10 | 0.265272E+09 | 0.00 | 1658802.67 | 14803513.35 | 0.588163E+09 | 0.130851E+10 | 0.00 | 0.83 |
October | 0.176843E+10 | 2141629.38 | 0.00 | 397090.95 | 0.00 | 0.175009E+10 | 0.527500E+09 | 0.00 | 0.60 |
November | 0.555286E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.498721E+10 | 0.00 | 0.00 | 0.49 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.823810E+10 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.656212E+10 | 0.205530E+10 | 0.00 | 8826301.05 | 48025690.57 | 0.444214E+11 | 0.584595E+10 | 0.00 | 0.65 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.176843E+10 | 0.832236E+09 | 0.00 | 2731397.17 | 15506675.29 | 0.993144E+10 | 0.162101E+10 | 0.00 | 1.00 |