Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820
Simulation Timestamp: 2020-06-03 19:19:03
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1998.89 | 956.26 | 956.26 |
Net Site Energy | 1998.89 | 956.26 | 956.26 |
Total Source Energy | 6330.48 | 3028.47 | 3028.47 |
Net Source Energy | 6330.48 | 3028.47 | 3028.47 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 718.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 704.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 110.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 277.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 58.74 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1998.89 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 718.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 704.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 110.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 277.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 58.74 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 389.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 504.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 956.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 389.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 504.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 956.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1998.888 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1998.888 | 100.00 |
Total On-Site and Utility Electric Sources | 1998.888 | 100.00 |
Total Electricity End Uses | 1998.888 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.33 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 222.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_HI_HONOLULU
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19 |
RunPeriod | RUNPERIOD 1 |
Weather File | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Latitude [deg] | 21.32 |
Longitude [deg] | -157.9 |
Elevation [m] | 2.00 |
Time Zone | -10.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 24.9638 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 27.8378 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 25.6850 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 18.3225 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 18.3225 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0629 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 22.0629 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 03-SEP-12:00 | - | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 75527.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 16071.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 5419.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 148921.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 75527.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 16071.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 5419.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2276.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 2230.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 351.39 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 407.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 878.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 186.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 6330.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1089.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1066.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 420.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 89.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3028.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1089.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1066.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 420.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 89.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3028.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 2.37 |
SMSTORE1 DIRECT AIR | 1.25 |
SMSTORE2 DIRECT AIR | 1.25 |
SMSTORE3 DIRECT AIR | 1.25 |
SMSTORE4 DIRECT AIR | 1.24 |
LGSTORE2 DIRECT AIR | 2.21 |
SMSTORE5 DIRECT AIR | 1.15 |
SMSTORE6 DIRECT AIR | 1.14 |
SMSTORE7 DIRECT AIR | 1.14 |
SMSTORE8 DIRECT AIR | 1.28 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 2.37 | 2.37 | 2.37 | 2.37 | 2.37 | 2.37 | 1.00 | 1.00 | 2.37 |
PSZ-AC_2:2 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.00 | 1.00 | 1.25 |
PSZ-AC_3:3 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.00 | 1.000000 | 1.25 |
PSZ-AC_4:4 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.00 | 1.00 | 1.25 |
PSZ-AC_5:5 | 1.24 | 1.24 | 1.24 | 1.24 | 1.24 | 1.24 | 1.00 | 1.00 | 1.24 |
PSZ-AC_6:6 | 2.21 | 2.21 | 2.21 | 2.21 | 2.21 | 2.21 | 1.00 | 1.00 | 2.21 |
PSZ-AC_7:7 | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 | 1.00 | 1.00 | 1.15 |
PSZ-AC_8:8 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.00 | 1.000000 | 1.14 |
PSZ-AC_9:9 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.00 | 1.00 | 1.14 |
PSZ-AC_10:10 | 1.28 | 1.28 | 1.28 | 1.28 | 1.28 | 1.28 | 1.00 | 1.00 | 1.28 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 2.37 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 1.25 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 1.25 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 1.25 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 1.24 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 2.21 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 1.15 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 1.14 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 1.14 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 1.28 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 2.37 | 2.37 | 2.37 | 2.37 | 52335.59 | 56649.46 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.25 | 1.25 | 1.25 | 1.25 | 27442.83 | 29810.05 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.25 | 1.25 | 1.25 | 1.25 | 27385.62 | 29728.59 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.25 | 1.25 | 1.25 | 1.25 | 27432.36 | 29792.30 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.24 | 1.24 | 1.24 | 1.24 | 27302.72 | 30471.58 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 2.21 | 2.21 | 2.21 | 2.21 | 49481.96 | 52897.17 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 1.15 | 1.15 | 1.15 | 1.15 | 25718.65 | 27844.98 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 1.14 | 1.14 | 1.14 | 1.14 | 25612.90 | 27698.37 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 1.14 | 1.14 | 1.14 | 1.14 | 25634.10 | 27749.73 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 1.28 | 1.28 | 1.28 | 1.28 | 27875.18 | 30954.82 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 2.37 | 1.19 | 2.37 | 49409.84 | 52335.59 | 26167.79 | 52335.59 | 0.706811 | 0.706810 | 0.706810 | 0.706810 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 1.25 | 0.625445 | 1.25 | 25897.18 | 27442.83 | 13721.42 | 27442.83 | 0.708410 | 0.708410 | 0.708410 | 0.708410 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.25 | 0.623675 | 1.25 | 25844.69 | 27385.62 | 13692.81 | 27385.62 | 0.708203 | 0.708200 | 0.708200 | 0.708200 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 1.25 | 0.625070 | 1.25 | 25887.80 | 27432.36 | 13716.18 | 27432.36 | 0.708350 | 0.708350 | 0.708350 | 0.708350 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 1.24 | 0.621180 | 1.24 | 25768.46 | 27302.72 | 13651.36 | 27302.72 | 0.707932 | 0.707930 | 0.707930 | 0.707930 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 2.21 | 1.10 | 2.21 | 46770.81 | 49481.96 | 24740.98 | 49481.96 | 0.702528 | 0.702530 | 0.702530 | 0.702530 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 1.15 | 0.573840 | 1.15 | 24309.04 | 25718.65 | 12859.33 | 25718.65 | 0.702584 | 0.702590 | 0.702590 | 0.702590 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 1.14 | 0.570700 | 1.14 | 24211.66 | 25612.90 | 12806.45 | 25612.90 | 0.702213 | 0.702210 | 0.702210 | 0.702210 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 1.14 | 0.571300 | 1.14 | 24231.31 | 25634.10 | 12817.05 | 25634.10 | 0.702274 | 0.702270 | 0.702270 | 0.702270 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 1.28 | 0.638950 | 1.28 | 26296.30 | 27875.18 | 13937.59 | 27875.18 | 0.710004 | 0.710000 | 0.710000 | 0.710000 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.37 | 2595.94 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.25 | 1426.15 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.25 | 1422.12 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.25 | 1425.29 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.24 | 1416.42 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 2.21 | 2416.29 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 1.15 | 1308.49 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 1.14 | 1301.32 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 1.14 | 1302.69 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 1.28 | 1456.94 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 56649.46 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 29810.05 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 29728.59 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 29792.30 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 30471.58 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 52897.17 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 27844.98 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 27698.37 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 27749.73 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 30954.82 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.20 | 24.80 | 23.70 | 22.50 | 22.80 | 23.20 | 23.80 | 25.20 | 25.90 | 26.90 | 27.10 | 26.90 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 | 21.32 | -157.93 | -10.00 | 2.00 | 101301 | 1.2040 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 24.92 | 4.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 24.964 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.264 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 27.838 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 32.138 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 25.685 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 29.985 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.322 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.622 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 2313.751 | 6.641 | 77.135 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2313.751 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1657.501 | 9.515 | 110.515 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1657.501 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1282.501 | 7.363 | 85.511 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1282.501 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 6383.296 | 18.322 | 212.804 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6383.296 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 3191.648 | 18.322 | 212.805 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3191.648 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.3762 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.7871 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1995 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2888 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.599 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.037 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.937 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.386 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.61039648E-06 | 0.16815647E-08 | -0.37447326E-05 | 0.10149002E-16 |
19 | 2 | 0.76989337 | 0.22941655E-02 | 1.0458372 | -0.71793422E-06 |
20 | 1 | -21.843031 | 0.15409339 | -6.3407615 | 0.20050303 |
21 | 0 | 21.373924 | 0.14439780 | 5.5957134 | |
22 | 7 | -0.29735092E-12 | 0.24575595E-14 | -0.94456721E-13 | 0.15324278E-15 |
23 | 6 | 0.28546880E-07 | 0.22114619E-09 | 0.65405332E-08 | -0.13451374E-12 |
24 | 5 | -0.18947583E-03 | 0.18937623E-05 | -0.97466953E-04 | 0.64660656E-08 |
25 | 4 | 0.29140875 | 0.92215111E-03 | 0.99417931E-01 | -0.33466744E-04 |
26 | 3 | -7.2517161 | 0.28579858E-01 | -2.3345767 | 0.28937395E-01 |
27 | 2 | 40.822959 | 0.10163225 | 15.247323 | -0.33280368 |
28 | 1 | -80.508872 | 0.45869584E-01 | -29.125752 | 1.0778326 |
29 | 0 | 46.824339 | 0.92288667E-03 | 16.291614 | |
30 | 7 | -0.21163652E-08 | -0.68723841E-15 | 0.43910983E-14 | -0.57684426E-16 |
31 | 6 | 0.56109385E-05 | 0.38186281E-08 | 0.31898696E-02 | -0.26759299E-04 |
32 | 5 | -0.40164657E-03 | 0.22608617E-05 | -0.22372456 | 0.19561502E-02 |
33 | 4 | 0.92272104E-02 | 0.10289840E-03 | 4.8295456 | -0.45264980E-01 |
34 | 3 | -0.80993241E-01 | 0.81813938E-03 | -38.021416 | 0.39865375 |
35 | 2 | 0.28754352 | 0.13608947E-02 | 116.48395 | -1.4179393 |
36 | 1 | -0.41499682 | 0.41453381E-03 | -143.90731 | 2.0490399 |
37 | 0 | 0.20232414 | 0.10048102E-04 | 60.838472 | |
38 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
39 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
40 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
41 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
42 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
43 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
44 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
45 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
46 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
47 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
48 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
49 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
50 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
51 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
52 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
53 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
54 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
55 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
56 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
57 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
58 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
59 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
60 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
61 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
62 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
63 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
64 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
65 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
66 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
67 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
68 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
69 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
70 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
71 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
72 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
73 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
74 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
75 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
76 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
77 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
78 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
79 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
80 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
81 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
82 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
83 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
84 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
85 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
86 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
87 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
88 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
89 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
90 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
91 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
92 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
93 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
94 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479936E-14 | -0.41635794E-16 |
95 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
96 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
97 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
98 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
99 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
100 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
101 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
102 | 7 | -0.14484255E-08 | -0.22640907E-15 | 0.11860658E-13 | -0.17473455E-15 |
103 | 6 | 0.80640390E-05 | 0.55493782E-08 | 0.31828288E-02 | -0.26700235E-04 |
104 | 5 | -0.58275339E-03 | 0.32892043E-05 | -0.22332434 | 0.19526176E-02 |
105 | 4 | 0.13421983E-01 | 0.14977251E-03 | 4.8228790 | -0.45200897E-01 |
106 | 3 | -0.11791368 | 0.11914425E-02 | -37.983753 | 0.39823745 |
107 | 2 | 0.41875064 | 0.19825898E-02 | 116.41064 | -1.4169588 |
108 | 1 | -0.60444169 | 0.60433957E-03 | -143.86415 | 2.0483306 |
109 | 0 | 0.29470347 | 0.14596444E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 29 | 1 | VerySmooth | 5.834 | 0.251 | 0.110 | 0.250 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.10958 | 0.41407 | 0.41407 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.39562 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.286 | 8.224E-004 | 4.530E-004 | 0.571 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 6.149E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.648E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 0.164 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 7.565E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 8.210E-002 | 4.713E-004 | 3.194E-004 | 0.327 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.204 | 1.172E-003 | 5.440E-004 | 0.815 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 5.921E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 26923.20493 | 32307.84592 | 1.97649 | 2.37179 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 32.20000 | 1.43490E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 7670.63159 | 9204.75790 | 0.31876 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 14199.22388 | 17039.06865 | 1.04241 | 1.25089 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 32.20000 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 3583.81993 | 4300.58392 | 0.14968 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 14159.06350 | 16990.87620 | 1.03946 | 1.24735 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 3141.24981 | 3769.49977 | 0.13545 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 14190.70924 | 17028.85109 | 1.04178 | 1.25014 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 3181.34418 | 3817.61302 | 0.13718 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 14102.38538 | 16922.86245 | 1.03530 | 1.24236 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 3297.95176 | 3957.54211 | 0.14221 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 25060.46104 | 30072.55325 | 1.83971 | 2.20765 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 8183.99887 | 9820.79865 | 0.33905 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 13027.77997 | 15633.33596 | 0.95640 | 1.14768 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 4255.71389 | 5106.85667 | 0.17711 | 0.21254 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 12956.44040 | 15547.72847 | 0.95117 | 1.14140 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 4255.72521 | 5106.87026 | 0.17712 | 0.21255 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 12970.16603 | 15564.19924 | 0.95217 | 1.14260 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 32.08167 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 4502.22822 | 5402.67386 | 0.18708 | 0.22450 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 14507.83425 | 17409.40110 | 1.06491 | 1.27790 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 31.84500 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 5113.82695 | 6136.59234 | 0.21216 | 0.25459 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 35947.67 | 2.37179 | 2.37179 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 11847.79 | 0.41145 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 01:10:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 18845.33 | 1.25089 | 1.25089 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 18793.98 | 1.24735 | 1.24735 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 18830.63 | 1.25014 | 1.25014 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 18726.46 | 1.24236 | 1.24236 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 08:30:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 33737.79 | 2.20765 | 2.20765 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 11847.79 | 0.41145 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 17455.63 | 1.14768 | 1.14768 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 6082.41 | 0.21254 | 0.21254 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 17371.29 | 1.14140 | 1.14140 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 6082.64 | 0.21255 | 0.21255 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 17385.12 | 1.14260 | 1.14260 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 6361.29 | 0.22450 | 0.22450 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 19121.18 | 1.27790 | 1.27790 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 7064.60 | 0.25459 | 0.25459 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.37179 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.25089 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.24735 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.25014 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.24236 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.20765 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.14768 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.14140 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.14260 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.27790 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.37179 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.37179 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.37179 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.37179 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.37179 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.37179 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.25089 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.25089 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.25089 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.25089 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.25089 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.25089 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.24735 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.24735 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.24735 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.24735 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.24735 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.24735 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.25014 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.25014 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.25014 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.25014 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.25014 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.25014 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.24236 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.24236 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.24236 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.24236 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.24236 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.24236 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.20765 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.20765 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.20765 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.20765 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.20765 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 2.20765 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.14768 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.14768 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.14768 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.14768 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.14768 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 1.14768 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 1.00000 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.14140 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.14140 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.14140 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.14140 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.14140 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 1.14140 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 1.00000 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.14260 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.14260 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.14260 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.14260 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.14260 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 1.14260 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.27790 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.27790 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.27790 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.27790 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.27790 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 1.27790 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 2.37179 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.25089 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.24735 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.25014 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.24236 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 2.20765 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 1.14768 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 1.14140 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 1.14260 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 1.27790 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.37179 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.37179 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.37179 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.37179 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.37179 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.37179 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.18590 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.37179 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 49409.84186 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 52335.59000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 26167.79500 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 52335.59000 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70681 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70681 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70681 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70681 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 52335.59000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 56649.46095 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.37179 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2595.93740 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 56649.46095 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.25089 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.25089 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.25089 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.25089 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.25089 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.25089 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.62545 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.25089 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 25897.17703 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27442.83000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13721.41500 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27442.83000 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70841 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70841 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70841 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70841 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27442.83000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29810.04925 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.25089 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1426.15318 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29810.04925 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.24735 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.24735 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.24735 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.24735 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.24735 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.24735 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.62368 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.24735 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 25844.69324 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27385.62000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13692.81000 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27385.62000 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70820 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70820 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70820 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70820 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27385.62000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29728.58743 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.24735 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1422.11605 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29728.58743 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.25014 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.25014 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.25014 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.25014 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.25014 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.25014 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.62507 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.25014 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 25887.80129 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27432.36000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13716.18000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27432.36000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70835 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70835 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70835 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70835 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27432.36000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 29792.29698 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.25014 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1425.29457 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 29792.29698 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.24236 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.24236 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.24236 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.24236 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.24236 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.24236 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.62118 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.24236 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 25768.45594 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27302.72000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13651.36000 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27302.72000 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70793 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70793 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70793 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70793 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27302.72000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 30471.57741 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.24236 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1416.42290 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 30471.57741 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.20765 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.20765 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.20765 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.20765 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.20765 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.20765 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.10383 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.20765 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 46770.81367 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 49481.96000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 24740.98000 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 49481.96000 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70253 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70253 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70253 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70253 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 49481.96000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 52897.17055 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.20765 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2416.28994 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 52897.17055 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.14768 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.14768 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.14768 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.14768 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.14768 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.14768 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.57384 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.14768 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24309.03803 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 25718.65000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12859.32500 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 25718.65000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70258 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70259 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70259 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70259 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 25718.65000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27844.97713 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.14768 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1308.48672 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27844.97713 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.14140 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.14140 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.14140 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.14140 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.14140 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.14140 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.57070 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.14140 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24211.66198 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 25612.90000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12806.45000 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 25612.90000 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70221 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70221 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70221 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70221 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 25612.90000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27698.36610 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.14140 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1301.32123 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27698.36610 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.14260 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.14260 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.14260 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.14260 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.14260 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.14260 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.57130 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.14260 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24231.30804 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 25634.10000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12817.05000 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 25634.10000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70227 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70227 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70227 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70227 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 25634.10000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27749.72920 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.14260 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1302.68890 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27749.72920 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.27790 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.27790 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.27790 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.27790 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.27790 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.27790 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.63895 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.27790 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 26296.30136 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27875.18000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13937.59000 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27875.18000 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.71000 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.71000 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.71000 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.71000 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27875.18000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 30954.81893 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.27790 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1456.94185 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 30954.81893 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 50468.6 | 9.93 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 26458.3 | 30.37 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 26403.8 | 40.88 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 26448.4 | 51.26 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 26324.8 | 61.95 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 47743.7 | 42.46 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 24815.0 | 96.51 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 24714.2 | 107.40 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 24734.4 | 117.78 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 26869.5 | 118.47 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.199 | 0.190 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_1.06_SHGC_0.25 | N/A | 5.834 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.975 | 3.975 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.289 | 0.270 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.376 | 0.351 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 9 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 2.9160998820E-002 | 0.1355351710 | Pass | Pass | 5.7216319609E-002 | 0.3724285413 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 3.0962902864E-002 | 0.1573171813 | Pass | Pass | 0.1352722444 | 1.3029785276 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 5.3556176564E-002 | 0.1993821272 | Pass | Pass | 3.7488696236 | 43.9255920357 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 5.3675958782E-002 | 0.2010130870 | Pass | Pass | 0.1062459065 | 0.6521581638 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 5.2974476812E-002 | 0.1949506050 | Pass | Pass | 0.5991354043 | 6.2844952613 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 5.8532948208E-002 | 0.2033163962 | Pass | Pass | 0.1150891862 | 0.7750574007 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 5.7213071552E-002 | 0.2000318089 | Pass | Pass | 0.1193570448 | 0.8234486452 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 5.6917387910E-002 | 0.1976512705 | Pass | Pass | 0.1230720976 | 0.8607272672 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 5.6307604363E-002 | 0.1920626276 | Pass | Pass | 9.6571085991E-002 | 0.6250905595 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 6.3090691962E-002 | 0.1983803207 | Pass | Pass | 7.4973069506E-002 | 0.4998214267 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.00 | 16.20 | Wetbulb [C] | 1.90 | 320.00 |
HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 32.20 | 7.10 | 23.30 | Wetbulb [C] | 6.70 | 60.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.358 | 0.376 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.199 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.289 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 5.834 | 0.251 | 0.250 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 5.834 | 0.251 | 0.250 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 5.834 | 0.251 | 0.250 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_1.06_SHGC_0.25 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 5.834 | 0.251 | 0.250 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 5.834 | 0.251 | 0.250 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 5.834 | 0.251 | 0.250 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 117.88 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 6.6413 | 348.39 | 2313.75 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 42.73 |
SMSTORE1_LIGHTS | SMSTORE1 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 58.94 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 9.5153 | 174.19 | 1657.50 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 30.61 |
SMSTORE2_LIGHTS | SMSTORE2 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
SMSTORE3_LIGHTS | SMSTORE3 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
SMSTORE4_LIGHTS | SMSTORE4 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 46.71 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 7.3625 | 174.19 | 1282.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 18.77 |
LGSTORE2_LIGHTS | LGSTORE2 | 18.3225 | 348.39 | 6383.30 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 85.86 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 18.3225 | 174.19 | 3191.65 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 42.93 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 11.0315 | 4180.64 | 46118.53 | 704.17 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7048.38 | AstronomicalClock | - | 83.86 | 83.86 | 110.95 | |
Exterior Lighting Total | 7048.38 | 110.95 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 52335.59 | 36991.32 | 15344.27 | 0.71 | 3.30 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27442.83 | 19440.78 | 8002.05 | 0.71 | 3.50 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27385.62 | 19394.50 | 7991.12 | 0.71 | 3.50 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27432.36 | 19431.71 | 8000.65 | 0.71 | 3.50 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27302.72 | 19328.41 | 7974.31 | 0.71 | 3.50 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 49481.96 | 34762.56 | 14719.40 | 0.70 | 3.30 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 25718.65 | 18069.67 | 7648.98 | 0.70 | 3.50 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 25612.90 | 17985.63 | 7627.27 | 0.70 | 3.50 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 25634.10 | 18002.06 | 7632.04 | 0.70 | 3.50 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27875.18 | 19791.38 | 8083.80 | 0.71 | 3.50 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 50468.6 | 9.93 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 26458.3 | 30.37 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 26403.8 | 40.88 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 26448.4 | 51.26 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 26324.8 | 61.95 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 47743.7 | 42.46 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 24815.0 | 96.51 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 24714.2 | 107.40 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 24734.4 | 117.78 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 26869.5 | 118.47 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 56649.46 | 0.80 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29810.05 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29728.59 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 29792.30 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 30471.58 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 52897.17 | 0.80 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27844.98 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27698.37 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27749.73 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 30954.82 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 2.37 | 2595.94 | 1094.51 | 1.00 | 1.26 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.25 | 1426.15 | 1140.11 | 1.00 | 1.31 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.25 | 1422.12 | 1140.11 | 1.00 | 1.31 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.25 | 1425.29 | 1140.11 | 1.00 | 1.31 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.24 | 1416.42 | 1140.11 | 1.00 | 1.31 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 2.21 | 2416.29 | 1094.51 | 1.00 | 1.27 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.15 | 1308.49 | 1140.11 | 1.00 | 1.33 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.14 | 1301.32 | 1140.11 | 1.00 | 1.33 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.14 | 1302.69 | 1140.11 | 1.00 | 1.33 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.28 | 1456.94 | 1140.11 | 1.00 | 1.31 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 26923.20 | 32307.85 | 92.74 | 1.976 | 2.372 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 23.89 | 23.88 | 0.00968 | 32.20 | 0.01435 | 0.411 | 0.00 |
SMSTORE1 | 14199.22 | 17039.07 | 97.82 | 1.042 | 1.251 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.88 | 0.00970 | 32.20 | 0.01435 | 0.206 | 0.00 |
SMSTORE2 | 14159.06 | 16990.88 | 97.54 | 1.039 | 1.247 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00970 | 32.14 | 0.01435 | 0.206 | 0.00 |
SMSTORE3 | 14190.71 | 17028.85 | 97.76 | 1.042 | 1.250 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00970 | 32.14 | 0.01435 | 0.206 | 0.00 |
SMSTORE4 | 14102.39 | 16922.86 | 97.15 | 1.035 | 1.242 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00971 | 32.14 | 0.01435 | 0.206 | 0.00 |
LGSTORE2 | 25060.46 | 30072.55 | 86.32 | 1.840 | 2.208 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00972 | 32.14 | 0.01435 | 0.411 | 0.00 |
SMSTORE5 | 13027.78 | 15633.34 | 89.75 | 0.956 | 1.148 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00979 | 32.14 | 0.01435 | 0.206 | 0.00 |
SMSTORE6 | 12956.44 | 15547.73 | 89.26 | 0.951 | 1.141 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.00979 | 32.14 | 0.01435 | 0.206 | 0.00 |
SMSTORE7 | 12970.17 | 15564.20 | 89.35 | 0.952 | 1.143 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 23.89 | 23.88 | 0.00979 | 32.08 | 0.01435 | 0.206 | 0.00 |
SMSTORE8 | 14507.83 | 17409.40 | 99.94 | 1.065 | 1.278 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 23.89 | 23.88 | 0.00972 | 31.85 | 0.01435 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 7670.63 | 9204.76 | 26.42 | 0.319 | 0.411 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00935 | 16.20 | 0.01152 | 0.411 | 0.00 |
SMSTORE1 | 3583.82 | 4300.58 | 24.69 | 0.150 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00916 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE2 | 3141.25 | 3769.50 | 21.64 | 0.135 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00982 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE3 | 3181.34 | 3817.61 | 21.92 | 0.137 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00981 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE4 | 3297.95 | 3957.54 | 22.72 | 0.142 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00978 | 16.20 | 0.01152 | 0.206 | 0.00 |
LGSTORE2 | 8184.00 | 9820.80 | 28.19 | 0.339 | 0.411 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00951 | 16.20 | 0.01152 | 0.411 | 0.00 |
SMSTORE5 | 4255.71 | 5106.86 | 29.32 | 0.177 | 0.213 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00952 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE6 | 4255.73 | 5106.87 | 29.32 | 0.177 | 0.213 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00952 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE7 | 4502.23 | 5402.67 | 31.02 | 0.187 | 0.225 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00946 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE8 | 5113.83 | 6136.59 | 35.23 | 0.212 | 0.255 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00973 | 16.20 | 0.01152 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 2.37 | 2.37 | 0.41 | 0.41 | 2.3718 | 2.3718 | 2.3718 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.25 | 1.25 | 0.21 | 0.21 | 1.2509 | 1.2509 | 1.2509 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.25 | 1.25 | 0.21 | 0.21 | 1.2473 | 1.2473 | 1.2473 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 1.25 | 1.25 | 0.21 | 0.21 | 1.2501 | 1.2501 | 1.2501 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.24 | 1.24 | 0.21 | 0.21 | 1.2424 | 1.2424 | 1.2424 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 2.21 | 2.21 | 0.41 | 0.41 | 2.2077 | 2.2077 | 2.2077 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 1.15 | 1.15 | 0.21 | 0.21 | 1.1477 | 1.1477 | 1.1477 | 1.0000 | 1.0000 |
PSZ-AC_8:8 | 1.14 | 1.14 | 0.21 | 0.21 | 1.1414 | 1.1414 | 1.1414 | 1.0000 | 1.0000 |
PSZ-AC_9:9 | 1.14 | 1.14 | 0.22 | 0.22 | 1.1426 | 1.1426 | 1.1426 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 1.28 | 1.28 | 0.25 | 0.25 | 1.2779 | 1.2779 | 1.2779 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 52335.590 | 0.000 | 2.371790 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 52335.59 | 38439.34 | 2.371790 | 25.33 | 18.47 | 0.01048829 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 17.3478 | 23.88 | 0.00967797 | 52.3555 | 26923.20 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 56649.461 | 56649.461 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 01:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 01:10:00 | 56649.46 | 56649.46 | 2.371790 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 17.3478 | 21.11 | 0.00935013 | 59.8977 | 2702.17 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 27442.830 | 0.000 | 1.250890 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 27442.83 | 20187.73 | 1.250890 | 25.25 | 18.43 | 0.01046588 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 16.4464 | 23.88 | 0.00970153 | 52.4815 | 14199.22 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 29810.049 | 29810.049 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29810.05 | 29810.05 | 1.250891 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 16.4464 | 21.11 | 0.00915610 | 58.6739 | 1539.88 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 27385.620 | 0.000 | 1.247350 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27385.62 | 20133.85 | 1.247350 | 25.26 | 18.43 | 0.01047084 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 16.4931 | 23.88 | 0.00970404 | 52.4948 | 14155.76 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 29728.587 | 29728.587 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29728.59 | 29728.59 | 1.247350 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 16.4931 | 21.11 | 0.00982232 | 62.8734 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 27432.360 | 0.000 | 1.250140 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27432.36 | 20176.49 | 1.250140 | 25.25 | 18.43 | 0.01046735 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 16.4563 | 23.88 | 0.00970184 | 52.4831 | 14186.78 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 29792.297 | 29792.297 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29792.30 | 29792.30 | 1.250138 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 16.4563 | 21.11 | 0.00981292 | 62.8141 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 27302.720 | 0.000 | 1.242360 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27302.72 | 20057.59 | 1.242360 | 25.26 | 18.44 | 0.01047731 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 16.5593 | 23.88 | 0.00970804 | 52.5161 | 14098.61 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 30471.577 | 30471.577 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 08:30:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 08:30:00 | 30471.58 | 30471.58 | 1.242356 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 16.5594 | 21.11 | 0.00978063 | 62.6105 | 1668.77 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 49481.960 | 0.000 | 2.207650 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 49481.96 | 35947.11 | 2.207650 | 25.44 | 18.58 | 0.01058695 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 18.6376 | 23.88 | 0.00972398 | 52.6001 | 25052.78 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 52897.171 | 52897.171 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 52897.17 | 52897.17 | 2.207654 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 18.6376 | 21.11 | 0.00951474 | 60.9354 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 25718.650 | 0.000 | 1.147680 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 25718.65 | 18611.80 | 1.147680 | 25.38 | 18.58 | 0.01060748 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 17.9254 | 23.88 | 0.00978904 | 52.9474 | 13022.96 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 27844.977 | 27844.977 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27844.98 | 27844.98 | 1.147685 | 16.35 | 16.20 | 0.01145380 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 17.9254 | 21.11 | 0.00951531 | 60.9386 | 4255.71 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 25612.900 | 0.000 | 1.141400 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 25612.90 | 18515.87 | 1.141400 | 25.38 | 18.59 | 0.01061672 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 18.0241 | 23.88 | 0.00979481 | 52.9781 | 12951.57 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 27698.366 | 27698.366 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27698.37 | 27698.37 | 1.141400 | 16.35 | 16.20 | 0.01145374 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 18.0241 | 21.11 | 0.00951647 | 60.9459 | 4255.73 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 25634.100 | 0.000 | 1.142600 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 25634.10 | 18534.33 | 1.142600 | 25.38 | 18.59 | 0.01061522 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 18.0051 | 23.88 | 0.00979232 | 52.9648 | 12963.28 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 27749.729 | 27749.729 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27749.73 | 27749.73 | 1.142599 | 16.58 | 16.19 | 0.01134607 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 18.0051 | 21.11 | 0.00946239 | 60.6046 | 4502.23 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 27875.180 | 0.000 | 1.277900 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 27875.18 | 20464.13 | 1.277900 | 25.17 | 18.40 | 0.01046884 | 12.80 | 12.10 | 0.00850000 | 31.85 | 0.01434902 | 23.20 | 16.0988 | 23.88 | 0.00972432 | 52.6030 | 14507.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 30954.819 | 30954.819 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 30954.82 | 30954.82 | 1.277896 | 17.06 | 16.21 | 0.01117553 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 16.0989 | 21.11 | 0.00973365 | 62.3125 | 5113.83 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 52335.590 | 0.000 | 2.371790 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.3372 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 52335.59 | 38439.34 | 1.0000 | 2.85569016 | 2.371790 | 25.33 | 18.47 | 0.01048829 | 52174.2 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 52335.59 | 32.20 | 0.01434902 | 23.30 | 0.41145340 | 17.3478 | 23.88 | 0.00967797 | 23.88 | 0.00967797 | 52.3555 | 26923.20 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 56649.461 | 56649.461 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.371790 | 2.85569040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 01:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 01:10:00 | 56649.46 | 56649.46 | 1.0000 | 2.85569040 | 2.371790 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 56649.46 | 16.20 | 0.01151798 | 16.20 | 0.41145340 | 17.3478 | 21.11 | 0.00000000 | 21.11 | 0.00935013 | 59.8977 | 2702.17 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27442.830 | 0.000 | 1.250890 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.2955 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 27442.83 | 20187.73 | 1.0000 | 1.50610057 | 1.250890 | 25.25 | 18.43 | 0.01046588 | 52040.2 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27442.83 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 16.4464 | 23.88 | 0.00970153 | 23.88 | 0.00970153 | 52.4815 | 14199.22 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29810.049 | 29810.049 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.250891 | 1.50610175 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29810.05 | 29810.05 | 1.0000 | 1.50610175 | 1.250891 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29810.05 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 16.4464 | 21.11 | 0.00864342 | 21.11 | 0.00915610 | 58.6739 | 1539.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27385.620 | 0.000 | 1.247350 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.3048 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27385.62 | 20133.85 | 1.0000 | 1.50183833 | 1.247350 | 25.26 | 18.43 | 0.01047084 | 52057.1 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27385.62 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 16.4931 | 23.88 | 0.00970466 | 23.88 | 0.00970404 | 52.4948 | 14155.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29728.587 | 29728.587 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.247350 | 1.50183831 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29728.59 | 29728.59 | 1.0000 | 1.50183831 | 1.247350 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29728.59 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 16.4931 | 21.11 | 0.00000000 | 21.11 | 0.00982232 | 62.8734 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27432.360 | 0.000 | 1.250140 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.2983 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27432.36 | 20176.49 | 1.0000 | 1.50519755 | 1.250140 | 25.25 | 18.43 | 0.01046735 | 52045.2 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27432.36 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 16.4563 | 23.88 | 0.00970250 | 23.88 | 0.00970184 | 52.4831 | 14186.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 29792.297 | 29792.297 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.250138 | 1.50519501 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 29792.30 | 29792.30 | 1.0000 | 1.50519501 | 1.250138 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29792.30 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 16.4563 | 21.11 | 0.00000000 | 21.11 | 0.00981292 | 62.8141 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27302.720 | 0.000 | 1.242360 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.3168 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 27302.72 | 20057.59 | 1.0000 | 1.49583025 | 1.242360 | 25.26 | 18.44 | 0.01047731 | 52079.3 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27302.72 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 16.5593 | 23.88 | 0.00970870 | 23.88 | 0.00970804 | 52.5161 | 14098.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 30471.577 | 30471.577 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.242356 | 1.49582601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 08:30:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 08:30:00 | 30471.58 | 30471.58 | 1.0000 | 1.49582601 | 1.242356 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30471.58 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 16.5594 | 20.43 | 0.00476442 | 21.11 | 0.00978063 | 62.6105 | 1668.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 49481.960 | 0.000 | 2.207650 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.5206 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 49481.96 | 35947.11 | 1.0000 | 2.65806180 | 2.207650 | 25.44 | 18.58 | 0.01058695 | 52536.1 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 49481.96 | 32.20 | 0.01434902 | 23.30 | 0.41145340 | 18.6376 | 23.88 | 0.00972485 | 23.88 | 0.00972398 | 52.6001 | 25052.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 52897.171 | 52897.171 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.207654 | 2.65806717 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 52897.17 | 52897.17 | 1.0000 | 2.65806717 | 2.207654 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 52897.17 | 16.20 | 0.01151798 | 16.20 | 0.41145340 | 18.6376 | 21.11 | 0.00000000 | 21.11 | 0.00951474 | 60.9354 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 25718.650 | 0.000 | 1.147680 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.5588 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 25718.65 | 18611.80 | 1.0000 | 1.38183333 | 1.147680 | 25.38 | 18.58 | 0.01060748 | 52527.6 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25718.65 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 17.9254 | 23.88 | 0.00978995 | 23.88 | 0.00978904 | 52.9474 | 13022.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27844.977 | 27844.977 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.147685 | 1.38183903 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27844.98 | 27844.98 | 1.0000 | 1.38183903 | 1.147685 | 16.35 | 16.20 | 0.01145380 | 45418.7 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27844.98 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 17.9254 | 20.77 | 0.00951531 | 21.11 | 0.00951531 | 60.9386 | 4255.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 25612.900 | 0.000 | 1.141400 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.5760 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 25612.90 | 18515.87 | 1.0000 | 1.37427207 | 1.141400 | 25.38 | 18.59 | 0.01061672 | 52559.5 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25612.90 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 18.0241 | 23.88 | 0.00979572 | 23.88 | 0.00979481 | 52.9781 | 12951.57 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27698.366 | 27698.366 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.141400 | 1.37427185 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27698.37 | 27698.37 | 1.0000 | 1.37427185 | 1.141400 | 16.35 | 16.20 | 0.01145374 | 45418.8 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27698.37 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 18.0241 | 20.77 | 0.00951647 | 21.11 | 0.00951647 | 60.9459 | 4255.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 25634.100 | 0.000 | 1.142600 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.5732 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 25634.10 | 18534.33 | 1.0000 | 1.37571690 | 1.142600 | 25.38 | 18.59 | 0.01061522 | 52554.3 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25634.10 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 18.0051 | 23.88 | 0.00979480 | 23.88 | 0.00979232 | 52.9648 | 12963.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27749.729 | 27749.729 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.142599 | 1.37571619 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 27749.73 | 27749.73 | 1.0000 | 1.37571619 | 1.142599 | 16.58 | 16.19 | 0.01134607 | 45385.9 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27749.73 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 18.0051 | 20.74 | 0.00946239 | 21.11 | 0.00946239 | 60.6046 | 4502.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27875.180 | 0.000 | 1.277900 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.3011 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 27875.18 | 20464.13 | 1.0000 | 1.53862123 | 1.277900 | 25.17 | 18.40 | 0.01046884 | 51961.0 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27875.18 | 31.85 | 0.01434902 | 23.20 | 0.20572670 | 16.0988 | 23.89 | 0.00972432 | 23.88 | 0.00972432 | 52.6030 | 14507.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 30954.819 | 30954.819 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.277896 | 1.53861640 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 30954.82 | 30954.82 | 1.0000 | 1.53861640 | 1.277896 | 17.06 | 16.21 | 0.01117553 | 45450.8 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30954.82 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 16.0989 | 20.70 | 0.00973365 | 21.11 | 0.00973365 | 62.3125 | 5113.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 5817.17 | 83.33 | 83.33 |
SMSTORE1 | 5795.50 | 23.17 | 23.17 |
SMSTORE2 | 4386.67 | 106.50 | 106.50 |
SMSTORE3 | 4386.67 | 106.83 | 106.83 |
SMSTORE4 | 4385.67 | 107.17 | 107.17 |
LGSTORE2 | 4018.00 | 97.50 | 97.50 |
SMSTORE5 | 4005.67 | 98.33 | 98.33 |
SMSTORE6 | 4004.50 | 99.67 | 99.67 |
SMSTORE7 | 4003.50 | 102.67 | 102.67 |
SMSTORE8 | 4004.17 | 120.67 | 120.67 |
Facility | 5926.33 | 222.17 | 222.17 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 0.00 | 0.33 | 0.00 | 0.33 |
SMSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 1.67 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 2.00 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 1.33 | 0.00 | 0.00 |
LGSTORE2 | 0.00 | 3.50 | 0.00 | 0.00 |
SMSTORE5 | 0.00 | 2.00 | 0.00 | 0.00 |
SMSTORE6 | 0.00 | 1.83 | 0.00 | 0.00 |
SMSTORE7 | 0.00 | 1.67 | 0.00 | 0.00 |
SMSTORE8 | 0.00 | 2.00 | 0.00 | 0.00 |
Facility | 0.00 | 5.83 | 0.00 | 0.33 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.842 | 0.373 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.690 | 0.399 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.843 | 0.519 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.843 | 0.519 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.843 | 0.519 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 0.843 | 0.487 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 0.843 | 0.553 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 0.843 | 0.553 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 0.843 | 0.553 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 0.843 | 0.598 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.826 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.114 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.825 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.825 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.825 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.22 | 30.00 | 1805.20 | 0.827 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.61 | 15.00 | 902.60 | 0.827 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.61 | 15.00 | 902.60 | 0.827 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.61 | 15.00 | 902.60 | 0.827 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.61 | 15.00 | 902.60 | 0.827 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
Electricity:Building | 832.89 | 2755.34 | 01-JAN-00:10 | 51902.14 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 186.96 | 509.76 | 01-JAN-00:10 | 9610.45 | 01-JAN-10:10 |
InteriorLights:Electricity | 704.17 | 2305.93 | 01-JAN-00:10 | 43812.60 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 160.61 | 434.85 | 01-JAN-00:10 | 8262.19 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 704.17 | 2305.93 | 01-JAN-00:10 | 43812.60 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 102.73 | 279.91 | 01-JAN-00:10 | 5280.82 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 89.55 | 242.46 | 01-JAN-00:10 | 4606.69 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 75.94 | 261.16 | 01-JAN-00:10 | 4924.57 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 65.47 | 223.71 | 01-JAN-00:10 | 4250.44 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 105.13 | 394.07 | 01-JAN-00:10 | 7412.39 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 85.86 | 319.16 | 01-JAN-00:10 | 6064.13 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 52.56 | 197.03 | 01-JAN-00:10 | 3706.19 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 42.93 | 159.58 | 01-JAN-00:10 | 3032.07 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
Electricity:Plant | 58.74 | 1218.00 | 07-MAY-08:10 | 11790.50 | 11-JAN-13:30 |
WaterSystems:Electricity | 58.74 | 1218.00 | 07-MAY-08:10 | 11790.50 | 11-JAN-13:30 |
Water Heater:WaterSystems:Electricity | 58.74 | 1218.00 | 07-MAY-08:10 | 11790.50 | 11-JAN-13:30 |
ElectricityPurchased:Facility | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
ElectricityPurchased:Plant | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
Cogeneration:ElectricityPurchased | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
ElectricityNet:Plant | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
Cogeneration:ElectricityNet | 1998.89 | 3973.34 | 01-JAN-07:20 | 148921.07 | 03-SEP-13:00 |
Electricity:HVAC | 996.30 | 0.00 | 01-JAN-00:10 | 91649.72 | 03-SEP-13:30 |
Fans:Electricity | 277.38 | 0.00 | 01-JAN-00:10 | 16071.65 | 04-JAN-17:10 |
General:Fans:Electricity | 277.38 | 0.00 | 01-JAN-00:10 | 16071.65 | 04-JAN-17:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 718.92 | 0.00 | 01-JAN-00:10 | 75578.07 | 03-SEP-13:30 |
ExteriorLights:Electricity | 110.95 | 0.00 | 01-JAN-07:20 | 7048.38 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 110.95 | 0.00 | 01-JAN-07:20 | 7048.38 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:Gas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 3755.97 | 0.00 | 01-JAN-00:10 | 389603.61 | 03-SEP-14:10 |
EnergyTransfer:Building | 1299.65 | 0.00 | 01-JAN-00:10 | 135080.94 | 01-OCT-13:00 |
EnergyTransfer:Zone:LGSTORE1 | 266.80 | 0.00 | 01-JAN-00:10 | 22685.23 | 01-OCT-13:00 |
Heating:EnergyTransfer | 6.73 | 0.00 | 01-JAN-00:10 | 20999.91 | 03-SEP-16:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 0.32 | 0.00 | 01-JAN-00:10 | 2506.88 | 03-FEB-08:20 |
Cooling:EnergyTransfer | 1292.92 | 0.00 | 01-JAN-00:10 | 135080.94 | 01-OCT-13:00 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 266.48 | 0.00 | 01-JAN-00:10 | 22685.23 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE1 | 141.49 | 0.00 | 01-JAN-00:10 | 11929.24 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 0.17 | 0.00 | 01-JAN-00:10 | 1370.57 | 03-FEB-08:20 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 141.33 | 0.00 | 01-JAN-00:10 | 11929.24 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE2 | 109.95 | 0.00 | 01-JAN-00:10 | 11784.48 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 1.02 | 0.00 | 01-JAN-00:10 | 2339.46 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 108.94 | 0.00 | 01-JAN-00:10 | 11784.48 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE3 | 110.16 | 0.00 | 01-JAN-00:10 | 11817.79 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 1.02 | 0.00 | 01-JAN-00:10 | 2337.90 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 109.14 | 0.00 | 01-JAN-00:10 | 11817.79 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE4 | 108.02 | 0.00 | 01-JAN-00:10 | 11702.15 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 1.04 | 0.00 | 01-JAN-00:10 | 2342.49 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 106.98 | 0.00 | 01-JAN-00:10 | 11702.15 | 01-OCT-13:00 |
EnergyTransfer:Zone:LGSTORE2 | 181.57 | 0.00 | 01-JAN-00:10 | 20987.43 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 1.03 | 0.00 | 01-JAN-00:10 | 4580.72 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 180.54 | 0.00 | 01-JAN-00:10 | 20987.43 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE5 | 93.46 | 0.00 | 01-JAN-00:10 | 10973.57 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 0.54 | 0.00 | 01-JAN-00:10 | 2356.57 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 92.92 | 0.00 | 01-JAN-00:10 | 10973.57 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE6 | 92.55 | 0.00 | 01-JAN-00:10 | 10911.01 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 0.54 | 0.00 | 01-JAN-00:10 | 2358.11 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 92.01 | 0.00 | 01-JAN-00:10 | 10911.01 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE7 | 91.99 | 0.00 | 01-JAN-00:10 | 10945.88 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 0.54 | 0.00 | 01-JAN-00:10 | 2357.60 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 91.45 | 0.00 | 01-JAN-00:10 | 10945.88 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE8 | 103.66 | 0.00 | 01-JAN-00:10 | 12453.36 | 11-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 0.53 | 0.00 | 01-JAN-00:10 | 2327.07 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 103.13 | 0.00 | 01-JAN-00:10 | 12453.36 | 11-OCT-13:00 |
EnergyTransfer:HVAC | 2456.31 | 0.00 | 01-JAN-00:10 | 259763.81 | 05-SEP-13:00 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 2456.31 | 0.00 | 01-JAN-00:10 | 259763.81 | 05-SEP-13:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 0.320 | -266.477 | 0.000 | 0.000 | 12.381 | 160.608 | 26.357 | 21.260 | 0.000 | 17.955 | 35.714 | 0.000 | -5.447 | 0.000 | -2.670 | -0.001 |
SMSTORE1 | 0.000 | 0.000 | 0.166 | -141.322 | 0.000 | 0.000 | 6.190 | 89.549 | 13.179 | 10.623 | 0.000 | 9.742 | 15.512 | 0.000 | -2.742 | 0.000 | -0.896 | -0.000 |
SMSTORE2 | 0.000 | 0.000 | 1.016 | -108.934 | 0.000 | 0.000 | 3.715 | 65.475 | 10.467 | 10.584 | 0.000 | 9.508 | 12.607 | 0.000 | -3.070 | 0.000 | -1.368 | 0.000 |
SMSTORE3 | 0.000 | 0.000 | 1.018 | -109.141 | 0.000 | 0.000 | 3.715 | 65.475 | 10.467 | 10.581 | 0.000 | 9.508 | 12.845 | 0.000 | -3.087 | 0.000 | -1.381 | 0.000 |
SMSTORE4 | 0.000 | 0.000 | 1.038 | -106.974 | 0.000 | 0.000 | 3.716 | 65.475 | 10.467 | 10.598 | 0.000 | 9.509 | 10.540 | 0.000 | -3.032 | 0.000 | -1.336 | -0.000 |
LGSTORE2 | 0.000 | 0.000 | 1.027 | -180.534 | 0.000 | 0.000 | 12.758 | 85.864 | 19.261 | 21.308 | 0.000 | 16.763 | 31.644 | 0.000 | -5.640 | 0.000 | -2.451 | -0.001 |
SMSTORE5 | 0.000 | 0.000 | 0.540 | -92.914 | 0.000 | 0.000 | 6.379 | 42.932 | 9.631 | 10.669 | 0.000 | 9.515 | 17.211 | 0.000 | -2.745 | 0.000 | -1.219 | -0.000 |
SMSTORE6 | 0.000 | 0.000 | 0.543 | -92.006 | 0.000 | 0.000 | 6.379 | 42.932 | 9.631 | 10.681 | 0.000 | 9.516 | 16.254 | 0.000 | -2.724 | 0.000 | -1.205 | -0.000 |
SMSTORE7 | 0.000 | 0.000 | 0.542 | -91.450 | 0.000 | 0.000 | 6.379 | 42.932 | 9.631 | 10.683 | 0.000 | 9.517 | 15.653 | 0.000 | -2.706 | 0.000 | -1.181 | -0.001 |
SMSTORE8 | 0.000 | 0.000 | 0.527 | -103.130 | 0.000 | 0.000 | 6.379 | 42.932 | 9.631 | 10.577 | 0.000 | 10.225 | 27.947 | 0.000 | -2.669 | 0.000 | -2.418 | -0.000 |
Total Facility | 0.000 | 0.000 | 6.736 | -1292.882 | 0.000 | 0.000 | 67.992 | 704.173 | 128.721 | 127.564 | 0.000 | 111.757 | 195.926 | 0.000 | -33.862 | 0.000 | -16.126 | -0.004 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -39334.50 | 0.00 | 0.00 | 93.28 | 434.85 | 74.90 | 1379.01 | 0.00 | 0.00 | 37590.73 | 0.00 | -0.00 | 0.00 | -238.27 | 0.00 |
SMSTORE1 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -21285.20 | 0.00 | 0.00 | 45.57 | 242.46 | 37.45 | 675.84 | 0.00 | 0.00 | 20409.16 | 0.00 | -0.00 | 0.00 | -125.28 | 0.00 |
SMSTORE2 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -20485.78 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 671.80 | 0.00 | 0.00 | 19682.70 | 0.00 | -0.00 | 0.00 | -129.88 | 0.00 |
SMSTORE3 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -20514.68 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 672.13 | 0.00 | 0.00 | 19710.88 | 0.00 | -0.00 | 0.00 | -129.49 | 0.00 |
SMSTORE4 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -20324.07 | 0.00 | 0.00 | 0.00 | 223.71 | 37.45 | 675.95 | 0.00 | 0.00 | 19511.94 | 0.00 | -0.00 | 0.00 | -124.98 | 0.00 |
LGSTORE2 | 20-DEC-08:62 | 0.00 | 0.00 | 0.00 | -37388.69 | 0.00 | 0.00 | 0.00 | 319.16 | 74.90 | 1441.00 | 0.00 | 0.00 | 35841.97 | 0.00 | -0.00 | 0.00 | -288.35 | 0.00 |
SMSTORE5 | 20-DEC-08:62 | 0.00 | 0.00 | 0.00 | -19272.70 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 719.48 | 0.00 | 0.00 | 18509.22 | 0.00 | -0.00 | 0.00 | -153.03 | 0.00 |
SMSTORE6 | 20-DEC-08:62 | 0.00 | 0.00 | 0.00 | -19157.34 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 721.33 | 0.00 | 0.00 | 18390.27 | 0.00 | -0.00 | 0.00 | -151.30 | 0.00 |
SMSTORE7 | 20-DEC-08:62 | 0.00 | 0.00 | 0.00 | -19078.73 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 725.47 | 0.00 | 0.00 | 18301.97 | 0.00 | -0.00 | 0.00 | -145.74 | 0.00 |
SMSTORE8 | 24-DEC-09:02 | 0.00 | 0.00 | 0.00 | -20456.61 | 0.00 | 0.00 | 0.00 | 159.58 | 37.45 | 1584.18 | 0.00 | 0.00 | 18767.51 | 0.00 | -0.00 | 0.00 | -92.12 | 0.00 |
Total Facility | 19-DEC-08:62 | 0.00 | 0.00 | 0.00 | -182132.17 | 0.00 | 0.00 | 293.31 | 8346.03 | 1460.61 | 8708.07 | 0.00 | 0.00 | 164500.07 | 0.00 | 0.00 | 0.00 | -1175.92 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 21-JUN-07:06 | 0.00 | 0.00 | 4673.73 | 0.00 | 0.00 | 0.00 | 85.81 | 434.85 | 74.90 | 226.27 | 0.00 | 356.39 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -5851.96 |
SMSTORE1 | 03-SEP-07:05 | 0.00 | 0.00 | 2723.01 | 0.00 | 0.00 | 0.00 | 41.96 | 242.46 | 37.45 | 84.91 | 0.00 | 161.65 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3291.43 |
SMSTORE2 | 03-SEP-16:01 | 0.00 | 0.00 | 2863.11 | 0.00 | 0.00 | 0.00 | 52.54 | 2237.07 | 374.52 | 679.47 | 0.00 | 2219.64 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -8426.35 |
SMSTORE3 | 03-SEP-16:01 | 0.00 | 0.00 | 2862.52 | 0.00 | 0.00 | 0.00 | 52.54 | 2237.07 | 374.52 | 679.06 | 0.00 | 2219.29 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -8424.99 |
SMSTORE4 | 03-SEP-16:01 | 0.00 | 0.00 | 2863.94 | 0.00 | 0.00 | 0.00 | 52.54 | 2237.07 | 374.52 | 679.57 | 0.00 | 2220.24 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -8427.88 |
LGSTORE2 | 03-SEP-16:01 | 0.00 | 0.00 | 5604.64 | 0.00 | 0.00 | 0.00 | 231.18 | 3191.65 | 749.03 | 1359.83 | 0.00 | 3928.53 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -15064.86 |
SMSTORE5 | 03-SEP-16:01 | 0.00 | 0.00 | 2854.61 | 0.00 | 0.00 | 0.00 | 115.59 | 1595.82 | 374.52 | 685.86 | 0.00 | 2227.81 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7854.21 |
SMSTORE6 | 03-SEP-16:01 | 0.00 | 0.00 | 2854.29 | 0.00 | 0.00 | 0.00 | 115.59 | 1595.82 | 374.52 | 686.46 | 0.00 | 2228.41 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7855.09 |
SMSTORE7 | 03-SEP-16:01 | 0.00 | 0.00 | 2853.95 | 0.00 | 0.00 | 0.00 | 115.59 | 1595.82 | 374.52 | 685.82 | 0.00 | 2228.22 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7853.92 |
SMSTORE8 | 03-SEP-16:11 | 0.00 | 0.00 | 2865.95 | 0.00 | 0.00 | 0.00 | 82.90 | 1595.82 | 374.52 | 595.02 | 0.00 | 1729.71 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7243.92 |
Total Facility | 03-SEP-16:01 | -33487.36 | 33487.36 | 25616.69 | -33487.36 | 0.00 | 0.00 | 2742.63 | 29155.05 | 5393.02 | 8184.57 | 0.00 | 26280.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -63884.82 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.3718 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.3718 | 0.1735 | 1.0000 | 0.4115 | 0.1735 | ||
PSZ-AC_2:2 | 1.2509 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2509 | 0.1645 | 1.0000 | 0.2057 | 0.1645 | ||
PSZ-AC_3:3 | 1.2473 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2473 | 0.1649 | 1.0000 | 0.2057 | 0.1649 | ||
PSZ-AC_4:4 | 1.2501 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2501 | 0.1646 | 1.0000 | 0.2057 | 0.1646 | ||
PSZ-AC_5:5 | 1.2424 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2424 | 0.1656 | 1.0000 | 0.2057 | 0.1656 | ||
PSZ-AC_6:6 | 2.2077 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.2077 | 0.1864 | 1.0000 | 0.4115 | 0.1864 | ||
PSZ-AC_7:7 | 1.1477 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1477 | 0.1793 | 1.0000 | 0.2057 | 0.1793 | ||
PSZ-AC_8:8 | 1.1414 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1414 | 0.1802 | 1.0000 | 0.2057 | 0.1802 | ||
PSZ-AC_9:9 | 1.1426 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1426 | 0.1801 | 1.0000 | 0.2057 | 0.1801 | ||
PSZ-AC_10:10 | 1.2779 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2779 | 0.1610 | 1.0000 | 0.2057 | 0.1610 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.3718 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.3718 | 1.0000 | 1.0000 | 0.4115 | 0.1735 | ||
PSZ-AC_2:2 | 1.2509 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2509 | 1.0000 | 1.0000 | 0.2057 | 0.1645 | ||
PSZ-AC_3:3 | 1.2473 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2473 | 1.0000 | 1.0000 | 0.2057 | 0.1649 | ||
PSZ-AC_4:4 | 1.2501 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2501 | 1.0000 | 1.0000 | 0.2057 | 0.1646 | ||
PSZ-AC_5:5 | 1.2424 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2424 | 1.0000 | 1.0000 | 0.2057 | 0.1656 | ||
PSZ-AC_6:6 | 2.2077 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.2077 | 1.0000 | 1.0000 | 0.4115 | 0.1864 | ||
PSZ-AC_7:7 | 1.1477 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1477 | 1.0000 | 1.0000 | 0.2057 | 0.1793 | ||
PSZ-AC_8:8 | 1.1414 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1414 | 1.0000 | 1.0000 | 0.2057 | 0.1802 | ||
PSZ-AC_9:9 | 1.1426 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1426 | 1.0000 | 1.0000 | 0.2057 | 0.1801 | ||
PSZ-AC_10:10 | 1.2779 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.2779 | 1.0000 | 1.0000 | 0.2057 | 0.1610 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.3718 | 2.3718 | 2.3718 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.2509 | 1.2509 | 1.2509 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.2473 | 1.2473 | 1.2473 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.2501 | 1.2501 | 1.2501 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.2424 | 1.2424 | 1.2424 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 2.2077 | 2.2077 | 2.2077 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.1477 | 1.1477 | 1.1477 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.1414 | 1.1414 | 1.1414 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.1426 | 1.1426 | 1.1426 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.2779 | 1.2779 | 1.2779 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.3718 | 2.3718 | 2.3718 | 2.3718 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.2509 | 1.2509 | 1.2509 | 1.2509 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.2473 | 1.2473 | 1.2473 | 1.2473 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.2501 | 1.2501 | 1.2501 | 1.2501 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.2424 | 1.2424 | 1.2424 | 1.2424 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 2.2077 | 2.2077 | 2.2077 | 2.2077 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.1477 | 1.1477 | 1.1477 | 1.1477 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.1414 | 1.1414 | 1.1414 | 1.1414 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.1426 | 1.1426 | 1.1426 | 1.1426 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.2779 | 1.2779 | 1.2779 | 1.2779 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.3718 | 2.3718 | 2.3718 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.2509 | 1.2509 | 1.2509 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.2473 | 1.2473 | 1.2473 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.2501 | 1.2501 | 1.2501 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.2424 | 1.2424 | 1.2424 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 2.2077 | 2.2077 | 2.2077 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.1477 | 1.1477 | 1.1477 | 0.2057 | 0.9680 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.1414 | 1.1414 | 1.1414 | 0.2057 | 0.9679 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.1426 | 1.1426 | 1.1426 | 0.2057 | 0.9164 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.2779 | 1.2779 | 1.2779 | 0.2057 | 0.8081 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.3718 | 2.3718 | 2.3718 | 2.3718 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.2509 | 1.2509 | 1.2509 | 1.2509 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.2473 | 1.2473 | 1.2473 | 1.2473 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.2501 | 1.2501 | 1.2501 | 1.2501 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.2424 | 1.2424 | 1.2424 | 1.2424 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 2.2077 | 2.2077 | 2.2077 | 2.2077 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.1477 | 1.1477 | 1.1477 | 1.1477 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.1414 | 1.1414 | 1.1414 | 1.1414 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.1426 | 1.1426 | 1.1426 | 1.1426 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.2779 | 1.2779 | 1.2779 | 1.2779 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Total gross floor area [m2] | 2090.32 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.33 |
Number of hours not met | 0.33 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 718.92 | 75578.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 704.17 | 43812.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 110.95 | 7048.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.72 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 277.38 | 16071.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 58.74 | 11790.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.72 | 1998.89 |
Natural Gas | 0.00 | 0.00 |
Additional | 0.00 | 0.00 |
Total | 128.72 | 1998.89 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 336.87 |
Space Heating | 0.00 |
Space Cooling | 343.93 |
Fans (All) | 132.70 |
Service Water Heating | 28.10 |
Receptacle Equipment | 61.58 |
Miscellaneous (All) | 956.26 |
Subtotal | 956.26 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.00 |
Subtotal | 0.00 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 35.23 |
Space Heating | 0.00 |
Space Cooling | 35.97 |
Fans (All) | 13.88 |
Service Water Heating | 2.94 |
Receptacle Equipment | 6.44 |
Miscellaneous | 5.55 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5131. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4888. | 8760. |
TYPE2_EQUIP_SCH | 3911. | 8760. |
TYPE3_EQUIP_SCH | 3600. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1A
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_HI_HONOLULU
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.192799E+11 | 38789.80 | 21-JAN-08:62 | 21.47 | 15.79 | 0.751726E+09 | 898.98 | 14-JAN-13:09 | 21.38 | 18.57 |
February | 0.180969E+11 | 32219.26 | 04-FEB-08:62 | 21.97 | 19.50 | 0.678591E+09 | 898.97 | 12-FEB-17:30 | 23.35 | 17.58 |
March | 0.204542E+11 | 35500.87 | 19-MAR-07:02 | 21.88 | 17.44 | 0.744931E+09 | 898.97 | 26-MAR-16:19 | 25.60 | 19.02 |
April | 0.198003E+11 | 36853.67 | 30-APR-07:02 | 22.15 | 17.80 | 0.726359E+09 | 898.98 | 02-APR-16:30 | 25.30 | 17.89 |
May | 0.226528E+11 | 37201.10 | 02-MAY-07:02 | 22.15 | 18.54 | 0.747445E+09 | 898.96 | 28-MAY-16:30 | 28.05 | 20.56 |
June | 0.227747E+11 | 34299.63 | 04-JUN-07:01 | 24.67 | 20.27 | 0.722107E+09 | 898.97 | 04-JUN-16:30 | 27.90 | 20.09 |
July | 0.252061E+11 | 32697.74 | 08-JUL-07:02 | 25.37 | 20.63 | 0.753673E+09 | 898.96 | 30-JUL-16:30 | 29.15 | 21.02 |
August | 0.255180E+11 | 33221.33 | 24-AUG-07:02 | 23.27 | 19.94 | 0.743158E+09 | 898.96 | 13-AUG-16:30 | 30.00 | 22.08 |
September | 0.250639E+11 | 33002.10 | 18-SEP-07:02 | 23.35 | 20.65 | 0.728283E+09 | 898.95 | 17-SEP-16:19 | 28.70 | 21.46 |
October | 0.247989E+11 | 35171.77 | 26-OCT-07:02 | 21.23 | 19.48 | 0.751747E+09 | 898.96 | 08-OCT-16:30 | 29.75 | 21.78 |
November | 0.219291E+11 | 36936.96 | 26-NOV-08:62 | 21.38 | 17.99 | 0.726973E+09 | 898.97 | 26-NOV-17:30 | 23.05 | 18.06 |
December | 0.209079E+11 | 39342.18 | 25-DEC-08:62 | 21.85 | 16.27 | 0.755533E+09 | 898.98 | 24-DEC-17:30 | 23.60 | 16.58 |
Annual Sum or Average | 0.266483E+12 | 0.883053E+10 | ||||||||
Minimum of Months | 0.180969E+11 | 32219.26 | 21.23 | 15.79 | 0.678591E+09 | 898.95 | 21.38 | 16.58 | ||
Maximum of Months | 0.255180E+11 | 39342.18 | 25.37 | 20.65 | 0.755533E+09 | 898.98 | 30.00 | 22.08 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.105302E+11 | 21176.01 | 21-JAN-08:62 | 21.47 | 15.79 | 0.375870E+09 | 449.49 | 22-JAN-17:30 | 23.90 | 17.76 |
February | 0.974235E+10 | 18967.21 | 04-FEB-08:62 | 21.97 | 19.50 | 0.339301E+09 | 449.48 | 12-FEB-17:30 | 23.35 | 17.58 |
March | 0.109566E+11 | 19896.12 | 19-MAR-07:02 | 21.88 | 17.44 | 0.372473E+09 | 449.48 | 26-MAR-16:19 | 25.60 | 19.02 |
April | 0.105990E+11 | 20543.78 | 30-APR-07:02 | 22.15 | 17.80 | 0.363187E+09 | 449.49 | 02-APR-16:30 | 25.30 | 17.89 |
May | 0.120192E+11 | 20590.37 | 02-MAY-07:02 | 22.15 | 18.54 | 0.373730E+09 | 449.48 | 28-MAY-16:30 | 28.05 | 20.56 |
June | 0.119722E+11 | 19309.34 | 04-JUN-07:01 | 24.67 | 20.27 | 0.361060E+09 | 449.48 | 04-JUN-16:30 | 27.90 | 20.09 |
July | 0.131713E+11 | 18686.68 | 08-JUL-07:02 | 25.37 | 20.63 | 0.376842E+09 | 449.48 | 30-JUL-16:30 | 29.15 | 21.02 |
August | 0.132932E+11 | 19037.85 | 24-AUG-07:02 | 23.27 | 19.94 | 0.371584E+09 | 449.48 | 13-AUG-16:30 | 30.00 | 22.08 |
September | 0.129698E+11 | 19187.93 | 25-SEP-07:01 | 24.37 | 22.10 | 0.364144E+09 | 449.47 | 17-SEP-16:30 | 28.60 | 21.38 |
October | 0.131195E+11 | 20043.43 | 26-OCT-07:02 | 21.23 | 19.48 | 0.375878E+09 | 449.48 | 08-OCT-16:30 | 29.75 | 21.78 |
November | 0.116632E+11 | 20501.36 | 26-NOV-08:62 | 21.38 | 17.99 | 0.363493E+09 | 449.48 | 26-NOV-17:30 | 23.05 | 18.06 |
December | 0.112893E+11 | 21288.38 | 25-DEC-08:62 | 21.85 | 16.27 | 0.377772E+09 | 449.49 | 24-DEC-17:30 | 23.60 | 16.58 |
Annual Sum or Average | 0.141326E+12 | 0.441533E+10 | ||||||||
Minimum of Months | 0.974235E+10 | 18686.68 | 21.23 | 15.79 | 0.339301E+09 | 449.47 | 23.05 | 16.58 | ||
Maximum of Months | 0.132932E+11 | 21288.38 | 25.37 | 22.10 | 0.377772E+09 | 449.49 | 30.00 | 22.08 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.796196E+10 | 19496.80 | 21-JAN-07:03 | 20.18 | 16.12 | 0.224278E+09 | 449.48 | 14-JAN-13:09 | 21.38 | 18.57 |
February | 0.734695E+10 | 18374.39 | 01-FEB-07:03 | 20.78 | 18.49 | 0.203759E+09 | 449.48 | 11-FEB-13:39 | 24.27 | 16.30 |
March | 0.837666E+10 | 18641.89 | 24-MAR-06:03 | 20.50 | 15.75 | 0.230328E+09 | 449.47 | 25-MAR-12:09 | 26.52 | 17.81 |
April | 0.798935E+10 | 19093.56 | 30-APR-07:02 | 22.15 | 17.80 | 0.219255E+09 | 449.47 | 01-APR-12:09 | 25.50 | 17.03 |
May | 0.930853E+10 | 18514.23 | 02-MAY-06:03 | 21.70 | 18.37 | 0.227511E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.933776E+10 | 17867.42 | 04-JUN-07:01 | 24.67 | 20.27 | 0.222652E+09 | 449.44 | 10-JUN-12:09 | 29.40 | 20.95 |
July | 0.101697E+11 | 16789.76 | 08-JUL-06:02 | 24.08 | 19.94 | 0.224382E+09 | 449.42 | 08-JUL-12:09 | 31.20 | 21.97 |
August | 0.105490E+11 | 17141.98 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230566E+09 | 449.40 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.100263E+11 | 17388.47 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219541E+09 | 449.41 | 16-SEP-12:09 | 27.20 | 22.88 |
October | 0.102396E+11 | 17423.16 | 19-OCT-06:02 | 19.40 | 17.64 | 0.224628E+09 | 449.41 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.905689E+10 | 18518.08 | 26-NOV-08:62 | 21.38 | 17.99 | 0.216866E+09 | 449.40 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.857458E+10 | 20490.24 | 25-DEC-08:62 | 21.85 | 16.27 | 0.224106E+09 | 449.46 | 23-DEC-13:09 | 25.77 | 17.78 |
Annual Sum or Average | 0.108937E+12 | 0.266787E+10 | ||||||||
Minimum of Months | 0.734695E+10 | 16789.76 | 19.40 | 15.75 | 0.203759E+09 | 449.40 | 21.38 | 16.30 | ||
Maximum of Months | 0.105490E+11 | 20490.24 | 24.67 | 20.27 | 0.230566E+09 | 449.48 | 31.20 | 22.88 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.794299E+10 | 19470.65 | 22-JAN-08:62 | 20.78 | 16.89 | 0.224275E+09 | 449.48 | 14-JAN-13:09 | 21.38 | 18.57 |
February | 0.733841E+10 | 18318.18 | 01-FEB-07:03 | 20.78 | 18.49 | 0.203757E+09 | 449.48 | 11-FEB-13:39 | 24.27 | 16.30 |
March | 0.837645E+10 | 18499.59 | 24-MAR-06:03 | 20.50 | 15.75 | 0.230326E+09 | 449.47 | 25-MAR-12:09 | 26.52 | 17.81 |
April | 0.798616E+10 | 19116.64 | 30-APR-07:02 | 22.15 | 17.80 | 0.219254E+09 | 449.47 | 01-APR-12:09 | 25.50 | 17.03 |
May | 0.932906E+10 | 18550.53 | 02-MAY-06:03 | 21.70 | 18.37 | 0.227511E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.936298E+10 | 17928.67 | 04-JUN-07:01 | 24.67 | 20.27 | 0.222652E+09 | 449.44 | 10-JUN-12:09 | 29.40 | 20.95 |
July | 0.102156E+11 | 16847.81 | 08-JUL-06:02 | 24.08 | 19.94 | 0.224383E+09 | 449.42 | 08-JUL-12:09 | 31.20 | 21.97 |
August | 0.105907E+11 | 17201.05 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230567E+09 | 449.40 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.100817E+11 | 17465.82 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219542E+09 | 449.41 | 16-SEP-12:09 | 27.20 | 22.88 |
October | 0.102845E+11 | 17469.64 | 19-OCT-06:02 | 19.40 | 17.64 | 0.224629E+09 | 449.41 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.906574E+10 | 18544.64 | 26-NOV-08:62 | 21.38 | 17.99 | 0.216865E+09 | 449.40 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.856995E+10 | 20519.15 | 25-DEC-08:62 | 21.85 | 16.27 | 0.224105E+09 | 449.46 | 23-DEC-13:09 | 25.77 | 17.78 |
Annual Sum or Average | 0.109144E+12 | 0.266787E+10 | ||||||||
Minimum of Months | 0.733841E+10 | 16847.81 | 19.40 | 15.75 | 0.203757E+09 | 449.40 | 21.38 | 16.30 | ||
Maximum of Months | 0.105907E+11 | 20519.15 | 24.67 | 20.27 | 0.230567E+09 | 449.48 | 31.20 | 22.88 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.774591E+10 | 19275.53 | 22-JAN-08:62 | 20.78 | 16.89 | 0.224258E+09 | 449.48 | 14-JAN-13:09 | 21.38 | 18.57 |
February | 0.715758E+10 | 17120.10 | 03-FEB-07:03 | 18.95 | 17.69 | 0.203741E+09 | 449.48 | 11-FEB-13:39 | 24.27 | 16.30 |
March | 0.817120E+10 | 18149.02 | 19-MAR-07:02 | 21.88 | 17.44 | 0.230308E+09 | 449.47 | 25-MAR-12:09 | 26.52 | 17.81 |
April | 0.779291E+10 | 18914.00 | 30-APR-07:02 | 22.15 | 17.80 | 0.219237E+09 | 449.47 | 01-APR-12:09 | 25.50 | 17.03 |
May | 0.914474E+10 | 18351.80 | 02-MAY-06:03 | 21.70 | 18.37 | 0.227494E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.918847E+10 | 17731.22 | 04-JUN-07:01 | 24.67 | 20.27 | 0.222636E+09 | 449.44 | 10-JUN-12:09 | 29.40 | 20.95 |
July | 0.100542E+11 | 16650.40 | 04-JUL-07:01 | 25.37 | 20.83 | 0.224368E+09 | 449.42 | 08-JUL-12:09 | 31.20 | 21.97 |
August | 0.104162E+11 | 16996.26 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230551E+09 | 449.40 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.992208E+10 | 17270.83 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219527E+09 | 449.41 | 16-SEP-12:09 | 27.20 | 22.88 |
October | 0.101109E+11 | 17259.81 | 19-OCT-06:02 | 19.40 | 17.64 | 0.224613E+09 | 449.41 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.889145E+10 | 18354.98 | 26-NOV-08:62 | 21.38 | 17.99 | 0.216849E+09 | 449.40 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.838175E+10 | 20328.55 | 25-DEC-08:62 | 21.85 | 16.27 | 0.224087E+09 | 449.46 | 23-DEC-13:09 | 25.77 | 17.78 |
Annual Sum or Average | 0.106977E+12 | 0.266767E+10 | ||||||||
Minimum of Months | 0.715758E+10 | 16650.40 | 18.95 | 16.27 | 0.203741E+09 | 449.40 | 21.38 | 16.30 | ||
Maximum of Months | 0.104162E+11 | 20328.55 | 25.37 | 20.83 | 0.230551E+09 | 449.48 | 31.20 | 22.88 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.128800E+11 | 36844.73 | 21-JAN-08:62 | 21.47 | 15.79 | 0.765278E+09 | 1198.63 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.119427E+11 | 30074.08 | 13-FEB-08:62 | 23.98 | 19.24 | 0.696881E+09 | 1198.59 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.136981E+11 | 32333.76 | 19-MAR-08:62 | 23.27 | 17.70 | 0.789301E+09 | 1198.57 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.129908E+11 | 34098.83 | 06-APR-07:02 | 22.48 | 16.83 | 0.752055E+09 | 1198.58 | 01-APR-14:09 | 25.60 | 17.37 |
May | 0.154451E+11 | 34395.08 | 02-MAY-07:02 | 22.15 | 18.54 | 0.777662E+09 | 1198.49 | 27-MAY-14:00 | 29.40 | 20.56 |
June | 0.155784E+11 | 31468.93 | 04-JUN-08:61 | 25.15 | 20.78 | 0.762753E+09 | 1198.49 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.170954E+11 | 30768.35 | 18-JUL-07:01 | 26.28 | 19.61 | 0.767536E+09 | 1198.45 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.177766E+11 | 31057.32 | 24-AUG-07:02 | 23.27 | 19.94 | 0.789670E+09 | 1198.42 | 05-AUG-14:00 | 31.10 | 22.32 |
September | 0.169264E+11 | 31555.49 | 19-SEP-07:02 | 22.98 | 20.28 | 0.752644E+09 | 1198.41 | 16-SEP-14:09 | 27.48 | 23.34 |
October | 0.172206E+11 | 32077.93 | 26-OCT-07:02 | 21.23 | 19.48 | 0.766012E+09 | 1198.41 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.150059E+11 | 33670.34 | 15-NOV-08:61 | 23.98 | 18.53 | 0.737328E+09 | 1198.49 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.139789E+11 | 37395.55 | 20-DEC-08:62 | 21.28 | 16.29 | 0.766758E+09 | 1198.57 | 23-DEC-15:00 | 24.60 | 17.23 |
Annual Sum or Average | 0.180539E+12 | 0.912388E+10 | ||||||||
Minimum of Months | 0.119427E+11 | 30074.08 | 21.23 | 15.79 | 0.696881E+09 | 1198.41 | 22.98 | 16.33 | ||
Maximum of Months | 0.177766E+11 | 37395.55 | 26.28 | 20.78 | 0.789670E+09 | 1198.63 | 31.10 | 23.34 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.659415E+10 | 18995.08 | 21-JAN-08:62 | 21.47 | 15.79 | 0.382632E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.611391E+10 | 15508.23 | 13-FEB-08:62 | 23.98 | 19.24 | 0.348433E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.701843E+10 | 16664.33 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394641E+09 | 599.28 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.666227E+10 | 17584.85 | 06-APR-07:02 | 22.48 | 16.83 | 0.376018E+09 | 599.29 | 01-APR-14:09 | 25.60 | 17.37 |
May | 0.795319E+10 | 17753.63 | 02-MAY-07:02 | 22.15 | 18.54 | 0.388819E+09 | 599.24 | 27-MAY-14:00 | 29.40 | 20.56 |
June | 0.801336E+10 | 16193.11 | 04-JUN-08:61 | 25.15 | 20.78 | 0.381364E+09 | 599.24 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.883186E+10 | 15863.95 | 18-JUL-07:01 | 26.28 | 19.61 | 0.383755E+09 | 599.22 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.919003E+10 | 16013.55 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394822E+09 | 599.20 | 05-AUG-14:00 | 31.10 | 22.32 |
September | 0.873454E+10 | 16296.59 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376304E+09 | 599.20 | 16-SEP-14:09 | 27.48 | 23.34 |
October | 0.890616E+10 | 16548.97 | 26-OCT-07:02 | 21.23 | 19.48 | 0.382993E+09 | 599.20 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.772167E+10 | 17360.59 | 15-NOV-08:61 | 23.98 | 18.53 | 0.368656E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.717661E+10 | 19276.36 | 20-DEC-08:62 | 21.28 | 16.29 | 0.383370E+09 | 599.28 | 23-DEC-15:00 | 24.60 | 17.23 |
Annual Sum or Average | 0.929162E+11 | 0.456181E+10 | ||||||||
Minimum of Months | 0.611391E+10 | 15508.23 | 21.23 | 15.79 | 0.348433E+09 | 599.20 | 22.98 | 16.33 | ||
Maximum of Months | 0.919003E+10 | 19276.36 | 26.28 | 20.78 | 0.394822E+09 | 599.31 | 31.10 | 23.34 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.651726E+10 | 18879.36 | 21-JAN-08:62 | 21.47 | 15.79 | 0.382627E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.604173E+10 | 15402.76 | 13-FEB-08:62 | 23.98 | 19.24 | 0.348429E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.693766E+10 | 16563.26 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394637E+09 | 599.28 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.658814E+10 | 17477.21 | 06-APR-07:02 | 22.48 | 16.83 | 0.376013E+09 | 599.29 | 01-APR-14:09 | 25.60 | 17.37 |
May | 0.787626E+10 | 17642.24 | 02-MAY-07:02 | 22.15 | 18.54 | 0.388814E+09 | 599.24 | 27-MAY-14:00 | 29.40 | 20.56 |
June | 0.793779E+10 | 16088.25 | 04-JUN-08:61 | 25.15 | 20.78 | 0.381360E+09 | 599.24 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.875684E+10 | 15765.56 | 18-JUL-07:01 | 26.28 | 19.61 | 0.383749E+09 | 599.22 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.911421E+10 | 15909.21 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394818E+09 | 599.20 | 05-AUG-14:00 | 31.10 | 22.32 |
September | 0.866023E+10 | 16189.40 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376299E+09 | 599.20 | 16-SEP-14:09 | 27.48 | 23.34 |
October | 0.883129E+10 | 16436.21 | 26-OCT-07:02 | 21.23 | 19.48 | 0.382988E+09 | 599.20 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.764650E+10 | 17250.76 | 15-NOV-08:61 | 23.98 | 18.53 | 0.368652E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.710014E+10 | 19160.99 | 20-DEC-08:62 | 21.28 | 16.29 | 0.383365E+09 | 599.28 | 23-DEC-15:00 | 24.60 | 17.23 |
Annual Sum or Average | 0.920081E+11 | 0.456175E+10 | ||||||||
Minimum of Months | 0.604173E+10 | 15402.76 | 21.23 | 15.79 | 0.348429E+09 | 599.20 | 22.98 | 16.33 | ||
Maximum of Months | 0.911421E+10 | 19160.99 | 26.28 | 20.78 | 0.394818E+09 | 599.31 | 31.10 | 23.34 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.642860E+10 | 17801.88 | 21-JAN-08:62 | 21.47 | 15.79 | 0.382622E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.595210E+10 | 15301.64 | 13-FEB-08:62 | 23.98 | 19.24 | 0.348424E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.684495E+10 | 16498.73 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394634E+09 | 599.28 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.652366E+10 | 17405.88 | 06-APR-07:02 | 22.48 | 16.83 | 0.376009E+09 | 599.29 | 01-APR-14:09 | 25.60 | 17.37 |
May | 0.784350E+10 | 17566.02 | 02-MAY-07:02 | 22.15 | 18.54 | 0.388812E+09 | 599.24 | 27-MAY-14:00 | 29.40 | 20.56 |
June | 0.791064E+10 | 16032.42 | 04-JUN-08:61 | 25.15 | 20.78 | 0.381358E+09 | 599.24 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.874763E+10 | 15708.23 | 18-JUL-07:01 | 26.28 | 19.61 | 0.383747E+09 | 599.22 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.911729E+10 | 15867.78 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394818E+09 | 599.20 | 05-AUG-14:00 | 31.10 | 22.32 |
September | 0.864541E+10 | 16142.26 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376297E+09 | 599.20 | 16-SEP-14:09 | 27.48 | 23.34 |
October | 0.881701E+10 | 16384.55 | 26-OCT-07:02 | 21.23 | 19.48 | 0.382986E+09 | 599.20 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.759322E+10 | 17165.42 | 15-NOV-08:61 | 23.98 | 18.53 | 0.368648E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.702821E+10 | 19082.42 | 20-DEC-08:62 | 21.28 | 16.29 | 0.383360E+09 | 599.28 | 23-DEC-15:00 | 24.60 | 17.23 |
Annual Sum or Average | 0.914522E+11 | 0.456171E+10 | ||||||||
Minimum of Months | 0.595210E+10 | 15301.64 | 21.23 | 15.79 | 0.348424E+09 | 599.20 | 22.98 | 16.33 | ||
Maximum of Months | 0.911729E+10 | 19082.42 | 26.28 | 20.78 | 0.394818E+09 | 599.31 | 31.10 | 23.34 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.702978E+10 | 18447.92 | 22-JAN-09:02 | 21.60 | 17.80 | 0.382646E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.637463E+10 | 14658.89 | 26-FEB-09:02 | 24.27 | 20.65 | 0.348452E+09 | 599.30 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.743160E+10 | 17684.09 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394669E+09 | 599.28 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.734320E+10 | 18430.54 | 30-APR-08:62 | 24.60 | 18.07 | 0.376050E+09 | 599.29 | 01-APR-14:09 | 25.60 | 17.37 |
May | 0.903470E+10 | 17492.72 | 30-MAY-07:02 | 24.18 | 18.91 | 0.388861E+09 | 599.24 | 27-MAY-14:00 | 29.40 | 20.56 |
June | 0.910134E+10 | 17318.68 | 04-JUN-08:61 | 25.15 | 20.78 | 0.381401E+09 | 599.24 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.101255E+11 | 16623.79 | 04-JUL-08:61 | 27.38 | 20.84 | 0.383819E+09 | 599.21 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.106451E+11 | 16044.09 | 07-AUG-07:01 | 25.78 | 20.41 | 0.394873E+09 | 599.19 | 05-AUG-14:00 | 31.10 | 22.32 |
September | 0.977770E+10 | 16189.65 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376360E+09 | 599.20 | 16-SEP-14:09 | 27.48 | 23.34 |
October | 0.101170E+11 | 16933.58 | 26-OCT-07:02 | 21.23 | 19.48 | 0.383049E+09 | 599.19 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.843274E+10 | 18409.64 | 15-NOV-08:61 | 23.98 | 18.53 | 0.368682E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.772002E+10 | 20460.97 | 24-DEC-09:02 | 23.50 | 17.22 | 0.383390E+09 | 599.29 | 23-DEC-15:00 | 24.60 | 17.23 |
Annual Sum or Average | 0.103133E+12 | 0.456225E+10 | ||||||||
Minimum of Months | 0.637463E+10 | 14658.89 | 21.23 | 17.22 | 0.348452E+09 | 599.19 | 22.98 | 16.33 | ||
Maximum of Months | 0.106451E+11 | 20460.97 | 27.38 | 20.84 | 0.394873E+09 | 599.31 | 31.10 | 23.34 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 34755068.35 | 3460.67 | 02-JAN-08:05 | 23.48 |
February | 28591695.08 | 3819.95 | 17-FEB-08:06 | 24.50 |
March | 32213440.41 | 3453.24 | 01-MAR-08:05 | 23.07 |
April | 39092274.19 | 3250.66 | 25-APR-07:06 | 24.18 |
May | 27660393.95 | 4416.60 | 17-MAY-07:05 | 25.28 |
June | 22391398.85 | 4674.68 | 21-JUN-07:06 | 26.78 |
July | 20048205.86 | 4473.84 | 08-JUL-07:05 | 25.37 |
August | 20051240.52 | 4443.00 | 27-AUG-07:06 | 26.38 |
September | 22781633.48 | 4522.35 | 03-SEP-07:06 | 27.48 |
October | 21106161.89 | 4292.73 | 07-OCT-07:06 | 26.05 |
November | 22759554.84 | 4603.64 | 22-NOV-08:06 | 26.28 |
December | 28083510.16 | 4068.42 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.319535E+09 | |||
Minimum of Months | 20048205.86 | 3250.66 | 23.07 | |
Maximum of Months | 39092274.19 | 4674.68 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 19213421.32 | 2005.51 | 02-JAN-08:05 | 23.48 |
February | 15993414.97 | 2152.74 | 18-FEB-08:05 | 24.60 |
March | 18125233.56 | 2026.31 | 01-MAR-08:05 | 23.07 |
April | 21054401.96 | 1809.12 | 05-APR-07:05 | 21.97 |
May | 12855327.47 | 2493.31 | 09-MAY-07:05 | 25.28 |
June | 11951108.40 | 2578.85 | 30-JUN-07:05 | 25.60 |
July | 11233190.58 | 2483.34 | 08-JUL-07:05 | 25.37 |
August | 12024062.03 | 2536.00 | 15-AUG-07:05 | 25.87 |
September | 9968608.76 | 2723.22 | 03-SEP-07:05 | 27.48 |
October | 10140665.34 | 2546.12 | 06-OCT-07:05 | 25.97 |
November | 10467760.02 | 2505.13 | 06-NOV-08:05 | 26.47 |
December | 13298054.83 | 2331.29 | 14-DEC-08:05 | 24.62 |
Annual Sum or Average | 0.166325E+09 | |||
Minimum of Months | 9968608.76 | 1809.12 | 21.97 | |
Maximum of Months | 21054401.96 | 2723.22 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 42580917.88 | 1784.77 | 11-JAN-07:05 | 22.12 |
February | 39193936.40 | 2004.45 | 17-FEB-07:06 | 24.40 |
March | 55307884.38 | 1859.73 | 14-MAR-06:05 | 23.22 |
April | 63365062.83 | 1907.93 | 09-APR-16:12 | 27.93 |
May | 94548218.58 | 2180.22 | 17-MAY-06:05 | 24.50 |
June | 98822609.62 | 2427.81 | 18-JUN-07:06 | 26.03 |
July | 0.123206E+09 | 2394.80 | 09-JUL-16:11 | 30.20 |
August | 0.125409E+09 | 2585.67 | 20-AUG-16:11 | 31.13 |
September | 0.118446E+09 | 2862.61 | 03-SEP-16:01 | 32.62 |
October | 0.117567E+09 | 2722.31 | 01-OCT-16:11 | 31.67 |
November | 74279700.65 | 2359.05 | 23-NOV-08:06 | 25.87 |
December | 63088249.63 | 2286.06 | 01-DEC-07:05 | 25.43 |
Annual Sum or Average | 0.101581E+10 | |||
Minimum of Months | 39193936.40 | 1784.77 | 22.12 | |
Maximum of Months | 0.125409E+09 | 2862.61 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 43383051.91 | 1784.16 | 11-JAN-07:05 | 22.12 |
February | 39948311.29 | 2011.59 | 17-FEB-07:06 | 24.40 |
March | 55577198.18 | 1859.75 | 14-MAR-06:05 | 23.22 |
April | 63709670.04 | 1911.66 | 09-APR-16:12 | 27.93 |
May | 93810859.87 | 2186.26 | 17-MAY-06:05 | 24.50 |
June | 99475065.55 | 2449.02 | 18-JUN-07:06 | 26.03 |
July | 0.122955E+09 | 2396.96 | 09-JUL-16:11 | 30.20 |
August | 0.125291E+09 | 2587.76 | 20-AUG-16:11 | 31.13 |
September | 0.118057E+09 | 2862.02 | 03-SEP-16:01 | 32.62 |
October | 0.116940E+09 | 2724.76 | 01-OCT-16:11 | 31.67 |
November | 74566538.60 | 2365.17 | 23-NOV-08:06 | 25.87 |
December | 63801661.16 | 2235.24 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.101752E+10 | |||
Minimum of Months | 39948311.29 | 1784.16 | 22.12 | |
Maximum of Months | 0.125291E+09 | 2862.02 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 44884693.46 | 1775.22 | 08-JAN-08:05 | 22.57 |
February | 41160913.83 | 1995.88 | 17-FEB-07:06 | 24.40 |
March | 57331942.73 | 1807.38 | 14-MAR-06:05 | 23.22 |
April | 65613256.76 | 1909.06 | 09-APR-16:12 | 27.93 |
May | 95542956.68 | 2120.14 | 07-MAY-07:05 | 24.60 |
June | 0.101620E+09 | 2371.44 | 18-JUN-07:06 | 26.03 |
July | 0.125199E+09 | 2394.13 | 09-JUL-16:11 | 30.20 |
August | 0.127658E+09 | 2584.99 | 20-AUG-16:11 | 31.13 |
September | 0.119040E+09 | 2863.44 | 03-SEP-16:01 | 32.62 |
October | 0.118895E+09 | 2721.71 | 01-OCT-16:11 | 31.67 |
November | 76014220.90 | 2289.12 | 23-NOV-08:06 | 25.87 |
December | 65214399.11 | 2285.86 | 01-DEC-07:05 | 25.43 |
Annual Sum or Average | 0.103817E+10 | |||
Minimum of Months | 41160913.83 | 1775.22 | 22.57 | |
Maximum of Months | 0.127658E+09 | 2863.44 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 56899662.02 | 3789.42 | 08-JAN-09:05 | 24.87 |
February | 55127591.82 | 3542.89 | 17-FEB-08:06 | 24.50 |
March | 65273834.29 | 3104.73 | 01-MAR-08:05 | 23.07 |
April | 85493961.28 | 3519.92 | 23-APR-08:05 | 24.27 |
May | 93008869.01 | 4317.80 | 14-MAY-08:06 | 26.28 |
June | 88976129.63 | 4456.16 | 21-JUN-07:06 | 26.78 |
July | 0.124175E+09 | 4887.21 | 04-JUL-08:06 | 27.38 |
August | 0.103358E+09 | 4962.28 | 20-AUG-16:02 | 31.42 |
September | 0.108569E+09 | 5603.73 | 03-SEP-16:01 | 32.62 |
October | 0.107829E+09 | 5207.61 | 01-OCT-16:02 | 31.93 |
November | 70198660.61 | 4379.34 | 23-NOV-09:06 | 27.38 |
December | 67492719.75 | 3804.21 | 02-DEC-08:06 | 25.68 |
Annual Sum or Average | 0.102640E+10 | |||
Minimum of Months | 55127591.82 | 3104.73 | 23.07 | |
Maximum of Months | 0.124175E+09 | 5603.73 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 32654588.80 | 2035.24 | 08-JAN-09:05 | 24.87 |
February | 30263122.53 | 1936.52 | 05-FEB-09:05 | 24.50 |
March | 35625778.58 | 1707.19 | 01-MAR-08:05 | 23.07 |
April | 46786503.42 | 1909.12 | 23-APR-08:05 | 24.27 |
May | 46694575.05 | 2233.73 | 14-MAY-08:06 | 26.28 |
June | 45647755.61 | 2301.14 | 30-JUN-07:05 | 25.60 |
July | 65081433.44 | 2532.85 | 30-JUL-08:06 | 27.38 |
August | 53848212.16 | 2548.41 | 27-AUG-08:06 | 28.07 |
September | 56276288.29 | 2854.13 | 03-SEP-16:01 | 32.62 |
October | 56200224.28 | 2653.12 | 01-OCT-16:02 | 31.93 |
November | 35380843.91 | 2229.83 | 19-NOV-09:06 | 26.88 |
December | 35679665.50 | 2064.66 | 03-DEC-09:06 | 26.10 |
Annual Sum or Average | 0.540139E+09 | |||
Minimum of Months | 30263122.53 | 1707.19 | 23.07 | |
Maximum of Months | 65081433.44 | 2854.13 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 33061431.98 | 2020.44 | 08-JAN-09:05 | 24.87 |
February | 30664461.58 | 1933.93 | 05-FEB-09:05 | 24.50 |
March | 35952275.56 | 1690.33 | 01-MAR-08:05 | 23.07 |
April | 46864273.36 | 1904.99 | 23-APR-08:05 | 24.27 |
May | 47048383.89 | 2206.19 | 14-MAY-08:06 | 26.28 |
June | 45070770.93 | 2285.97 | 30-JUN-07:05 | 25.60 |
July | 65439784.41 | 2521.19 | 30-JUL-08:06 | 27.38 |
August | 54254667.82 | 2541.17 | 27-AUG-08:06 | 28.07 |
September | 56374196.89 | 2853.80 | 03-SEP-16:01 | 32.62 |
October | 55920395.69 | 2653.59 | 01-OCT-16:02 | 31.93 |
November | 36138007.19 | 2207.65 | 19-NOV-09:06 | 26.88 |
December | 35877005.72 | 2054.77 | 03-DEC-09:06 | 26.10 |
Annual Sum or Average | 0.542666E+09 | |||
Minimum of Months | 30664461.58 | 1690.33 | 23.07 | |
Maximum of Months | 65439784.41 | 2853.80 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 33488791.05 | 2079.78 | 08-JAN-09:05 | 24.87 |
February | 31882447.19 | 1946.16 | 05-FEB-09:05 | 24.50 |
March | 35972742.17 | 1646.42 | 12-MAR-16:12 | 27.03 |
April | 47338992.59 | 1980.47 | 30-APR-08:04 | 24.60 |
May | 46953615.15 | 2154.57 | 14-MAY-08:06 | 26.28 |
June | 43521081.26 | 2273.03 | 30-JUN-07:05 | 25.60 |
July | 64682151.62 | 2522.83 | 30-JUL-08:06 | 27.38 |
August | 53594308.65 | 2540.79 | 27-AUG-08:06 | 28.07 |
September | 56319359.31 | 2853.46 | 03-SEP-16:01 | 32.62 |
October | 56226128.86 | 2654.74 | 01-OCT-16:02 | 31.93 |
November | 35979834.83 | 2163.98 | 19-NOV-09:06 | 26.88 |
December | 35605707.44 | 2179.67 | 06-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.541565E+09 | |||
Minimum of Months | 31882447.19 | 1646.42 | 24.50 | |
Maximum of Months | 64682151.62 | 2853.46 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 30429872.70 | 2242.78 | 08-JAN-09:05 | 24.87 |
February | 31762333.92 | 2078.81 | 05-FEB-09:05 | 24.50 |
March | 36640783.20 | 1921.88 | 15-MAR-07:04 | 23.68 |
April | 44384437.03 | 2224.14 | 30-APR-08:04 | 24.60 |
May | 46774756.23 | 2416.34 | 14-MAY-08:06 | 26.28 |
June | 41598072.32 | 2420.31 | 22-JUN-07:05 | 25.77 |
July | 62908921.06 | 2705.00 | 30-JUL-08:06 | 27.38 |
August | 50715895.88 | 2602.59 | 20-AUG-16:11 | 31.13 |
September | 53322717.59 | 2865.74 | 03-SEP-16:11 | 32.43 |
October | 56900781.78 | 2745.57 | 01-OCT-16:11 | 31.67 |
November | 34963451.56 | 2388.54 | 19-NOV-09:06 | 26.88 |
December | 36455641.40 | 2379.12 | 06-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.526858E+09 | |||
Minimum of Months | 30429872.70 | 1921.88 | 23.68 | |
Maximum of Months | 62908921.06 | 2865.74 | 32.43 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.136196E+11 | 8262.19 | 01-JAN-10:09 | 0.223514E+10 | 1348.26 | 01-JAN-10:09 |
February | 0.123234E+11 | 8262.19 | 01-FEB-10:09 | 0.202238E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.136478E+11 | 8262.19 | 01-MAR-10:09 | 0.223972E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.132157E+11 | 8262.19 | 01-APR-09:09 | 0.216880E+10 | 1348.26 | 01-APR-09:09 |
May | 0.136196E+11 | 8262.19 | 01-MAY-09:09 | 0.223514E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.132157E+11 | 8262.19 | 01-JUN-09:09 | 0.216880E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.136478E+11 | 8262.19 | 01-JUL-09:09 | 0.223972E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.136196E+11 | 8262.19 | 01-AUG-09:09 | 0.223514E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.132439E+11 | 8262.19 | 01-SEP-09:09 | 0.217339E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.136196E+11 | 8262.19 | 01-OCT-09:09 | 0.223514E+10 | 1348.26 | 01-OCT-09:09 |
November | 0.131593E+11 | 8262.19 | 01-NOV-09:09 | 0.215964E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.136759E+11 | 8262.19 | 01-DEC-10:09 | 0.224431E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.160608E+12 | 0.263573E+11 | ||||
Minimum of Months | 0.123234E+11 | 8262.19 | 0.202238E+10 | 1348.26 | ||
Maximum of Months | 0.136759E+11 | 8262.19 | 0.224431E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.759377E+10 | 4606.69 | 01-JAN-10:09 | 0.111757E+10 | 674.13 | 01-JAN-10:09 |
February | 0.687105E+10 | 4606.69 | 01-FEB-10:09 | 0.101119E+10 | 674.13 | 01-FEB-10:09 |
March | 0.760948E+10 | 4606.69 | 01-MAR-10:09 | 0.111986E+10 | 674.13 | 01-MAR-10:09 |
April | 0.736857E+10 | 4606.69 | 01-APR-09:09 | 0.108440E+10 | 674.13 | 01-APR-09:09 |
May | 0.759377E+10 | 4606.69 | 01-MAY-09:09 | 0.111757E+10 | 674.13 | 01-MAY-09:09 |
June | 0.736857E+10 | 4606.69 | 01-JUN-09:09 | 0.108440E+10 | 674.13 | 01-JUN-09:09 |
July | 0.760948E+10 | 4606.69 | 01-JUL-09:09 | 0.111986E+10 | 674.13 | 01-JUL-09:09 |
August | 0.759377E+10 | 4606.69 | 01-AUG-09:09 | 0.111757E+10 | 674.13 | 01-AUG-09:09 |
September | 0.738428E+10 | 4606.69 | 01-SEP-09:09 | 0.108669E+10 | 674.13 | 01-SEP-09:09 |
October | 0.759377E+10 | 4606.69 | 01-OCT-09:09 | 0.111757E+10 | 674.13 | 01-OCT-09:09 |
November | 0.733715E+10 | 4606.69 | 01-NOV-09:09 | 0.107982E+10 | 674.13 | 01-NOV-09:09 |
December | 0.762519E+10 | 4606.69 | 01-DEC-10:09 | 0.112215E+10 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.895488E+11 | 0.131787E+11 | ||||
Minimum of Months | 0.687105E+10 | 4606.69 | 0.101119E+10 | 674.13 | ||
Maximum of Months | 0.762519E+10 | 4606.69 | 0.112215E+10 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.552790E+10 | 4250.44 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.500604E+10 | 4250.44 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.564387E+10 | 4250.44 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.536361E+10 | 4250.44 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.558588E+10 | 4250.44 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.545059E+10 | 4250.44 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.549891E+10 | 4250.44 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.564387E+10 | 4250.44 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.536361E+10 | 4250.44 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.552790E+10 | 4250.44 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.536361E+10 | 4250.44 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.549891E+10 | 4250.44 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.654747E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.500604E+10 | 4250.44 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.564387E+10 | 4250.44 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.724555E+10 | 6064.13 | 01-JAN-11:09 | 0.162546E+10 | 1348.26 | 01-JAN-11:09 |
February | 0.656305E+10 | 6064.13 | 01-FEB-10:09 | 0.147229E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.741101E+10 | 6064.13 | 01-MAR-10:09 | 0.166213E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.703184E+10 | 6064.13 | 01-APR-09:09 | 0.157746E+10 | 1348.26 | 01-APR-09:09 |
May | 0.732828E+10 | 6064.13 | 01-MAY-09:09 | 0.164379E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.715593E+10 | 6064.13 | 01-JUN-09:09 | 0.160496E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.720419E+10 | 6064.13 | 01-JUL-09:09 | 0.161629E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.741101E+10 | 6064.13 | 01-AUG-09:09 | 0.166213E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.703184E+10 | 6064.13 | 01-SEP-09:09 | 0.157746E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.724555E+10 | 6064.13 | 01-OCT-10:09 | 0.162546E+10 | 1348.26 | 01-OCT-10:09 |
November | 0.703184E+10 | 6064.13 | 01-NOV-09:09 | 0.157746E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.720419E+10 | 6064.13 | 01-DEC-10:09 | 0.161629E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.858643E+11 | 0.192612E+11 | ||||
Minimum of Months | 0.656305E+10 | 6064.13 | 0.147229E+10 | 1348.26 | ||
Maximum of Months | 0.741101E+10 | 6064.13 | 0.166213E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362278E+10 | 3032.07 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.328152E+10 | 3032.07 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.370550E+10 | 3032.07 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.351592E+10 | 3032.07 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.366414E+10 | 3032.07 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.357797E+10 | 3032.07 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.360209E+10 | 3032.07 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.370550E+10 | 3032.07 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.351592E+10 | 3032.07 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.362278E+10 | 3032.07 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.351592E+10 | 3032.07 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.360209E+10 | 3032.07 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.429321E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.328152E+10 | 3032.07 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.370550E+10 | 3032.07 | 0.831065E+09 | 674.13 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.592807E+09 | 0.509840E+09 |
February | 0.163016E+10 | 0.123234E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.644040E+09 | 0.292149E+09 |
March | 0.178954E+10 | 0.136478E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.983212E+09 | 0.320586E+09 |
April | 0.174484E+10 | 0.132157E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107534E+10 | 0.281057E+09 |
May | 0.179537E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169517E+10 | 0.175418E+09 |
June | 0.173447E+10 | 0.132157E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168495E+10 | 0.149027E+09 |
July | 0.181028E+10 | 0.136478E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.232670E+10 | 0.124511E+09 |
August | 0.178501E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252972E+10 | 0.105728E+09 |
September | 0.174937E+10 | 0.132439E+11 | 0.217339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210091E+10 | 87360814.48 |
October | 0.180574E+10 | 0.136196E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219099E+10 | 0.107878E+09 |
November | 0.174613E+10 | 0.131593E+11 | 0.215964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130060E+10 | 0.220821E+09 |
December | 0.181481E+10 | 0.136759E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.830227E+09 | 0.295869E+09 |
Annual Sum or Average | 0.212115E+11 | 0.160608E+12 | 0.263573E+11 | 0.179547E+11 | 0.267025E+10 | ||||
Minimum of Months | 0.163016E+10 | 0.123234E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.592807E+09 | 87360814.48 |
Maximum of Months | 0.181481E+10 | 0.136759E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252972E+10 | 0.509840E+09 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326878E+09 | 0.196917E+09 |
February | 0.815075E+09 | 0.687105E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355388E+09 | 0.103182E+09 |
March | 0.894769E+09 | 0.760948E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539290E+09 | 0.105371E+09 |
April | 0.872416E+09 | 0.736857E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.588080E+09 | 91130217.04 |
May | 0.897684E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.925372E+09 | 53937851.57 |
June | 0.867232E+09 | 0.736857E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906149E+09 | 45920603.10 |
July | 0.905135E+09 | 0.760948E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125097E+10 | 38320471.33 |
August | 0.892501E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136625E+10 | 32043598.64 |
September | 0.874683E+09 | 0.738428E+10 | 0.108669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112870E+10 | 26270744.00 |
October | 0.902868E+09 | 0.759377E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119755E+10 | 33112164.53 |
November | 0.873064E+09 | 0.733715E+10 | 0.107982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.702238E+09 | 70124537.49 |
December | 0.907403E+09 | 0.762519E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.455077E+09 | 0.100044E+09 |
Annual Sum or Average | 0.106057E+11 | 0.895488E+11 | 0.131787E+11 | 0.974195E+10 | 0.896374E+09 | ||||
Minimum of Months | 0.815075E+09 | 0.687105E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326878E+09 | 26270744.00 |
Maximum of Months | 0.907403E+09 | 0.762519E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136625E+10 | 0.196917E+09 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323292E+09 | 0.249634E+09 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349992E+09 | 0.146422E+09 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530747E+09 | 0.151707E+09 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576990E+09 | 0.145428E+09 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905705E+09 | 90886287.78 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882507E+09 | 82603786.76 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120938E+10 | 70673496.57 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133630E+10 | 55906712.74 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109027E+10 | 50865969.23 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116523E+10 | 57269850.62 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687582E+09 | 0.112331E+09 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450489E+09 | 0.154735E+09 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 0.950848E+10 | 0.136846E+10 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323292E+09 | 50865969.23 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133630E+10 | 0.249634E+09 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323293E+09 | 0.249344E+09 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349992E+09 | 0.146467E+09 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530749E+09 | 0.152054E+09 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576992E+09 | 0.145691E+09 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905701E+09 | 91825785.11 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882502E+09 | 84211777.04 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120929E+10 | 73353979.97 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133619E+10 | 57860407.20 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108987E+10 | 53163943.99 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116517E+10 | 58696301.11 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687579E+09 | 0.113134E+09 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450488E+09 | 0.154967E+09 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 0.950781E+10 | 0.138077E+10 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323293E+09 | 53163943.99 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133619E+10 | 0.249344E+09 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323297E+09 | 0.245737E+09 |
February | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349996E+09 | 0.143722E+09 |
March | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530768E+09 | 0.148693E+09 |
April | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577016E+09 | 0.141931E+09 |
May | 0.544247E+09 | 0.558588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905776E+09 | 88412073.57 |
June | 0.532585E+09 | 0.545059E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882577E+09 | 79719710.81 |
July | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120951E+10 | 68554881.66 |
August | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133637E+10 | 54005384.27 |
September | 0.524810E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109018E+10 | 49368716.61 |
October | 0.537120E+09 | 0.552790E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116532E+10 | 55883294.08 |
November | 0.518979E+09 | 0.536361E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687630E+09 | 0.109270E+09 |
December | 0.536472E+09 | 0.549891E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450495E+09 | 0.151071E+09 |
Annual Sum or Average | 0.638324E+10 | 0.654747E+11 | 0.104672E+11 | 0.950894E+10 | 0.133637E+10 | ||||
Minimum of Months | 0.487879E+09 | 0.500604E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323297E+09 | 49368716.61 |
Maximum of Months | 0.551374E+09 | 0.564387E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133637E+10 | 0.245737E+09 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568666E+09 | 0.458877E+09 |
February | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.615473E+09 | 0.270770E+09 |
March | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.934553E+09 | 0.281818E+09 |
April | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101630E+10 | 0.268611E+09 |
May | 0.186509E+10 | 0.732828E+10 | 0.164379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159619E+10 | 0.161551E+09 |
June | 0.182945E+10 | 0.715593E+10 | 0.160496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155692E+10 | 0.137390E+09 |
July | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213385E+10 | 0.115663E+09 |
August | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235839E+10 | 90230802.62 |
September | 0.180380E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192559E+10 | 81752603.86 |
October | 0.183632E+10 | 0.724555E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205317E+10 | 99825165.86 |
November | 0.176881E+10 | 0.703184E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121160E+10 | 0.200874E+09 |
December | 0.183943E+10 | 0.720419E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.792191E+09 | 0.283780E+09 |
Annual Sum or Average | 0.218821E+11 | 0.858643E+11 | 0.192612E+11 | 0.167629E+11 | 0.245114E+10 | ||||
Minimum of Months | 0.167188E+10 | 0.656305E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568666E+09 | 81752603.86 |
Maximum of Months | 0.189386E+10 | 0.741101E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235839E+10 | 0.458877E+09 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323338E+09 | 0.240102E+09 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350001E+09 | 0.138977E+09 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531004E+09 | 0.141606E+09 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577199E+09 | 0.134129E+09 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906451E+09 | 78318599.29 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882678E+09 | 64389313.66 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121020E+10 | 52920823.88 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133803E+10 | 41359515.05 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109228E+10 | 37019186.25 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116669E+10 | 47764226.39 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687034E+09 | 98708196.14 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450166E+09 | 0.143290E+09 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.951509E+10 | 0.121858E+10 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323338E+09 | 37019186.25 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133803E+10 | 0.240102E+09 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323343E+09 | 0.238887E+09 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350007E+09 | 0.138012E+09 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531016E+09 | 0.140511E+09 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577216E+09 | 0.132893E+09 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906507E+09 | 77273946.54 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882762E+09 | 63032141.60 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121042E+10 | 51544556.03 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133819E+10 | 40335540.04 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109251E+10 | 35959879.19 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116685E+10 | 46980181.67 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687071E+09 | 97462309.10 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450174E+09 | 0.141977E+09 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.951607E+10 | 0.120487E+10 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323343E+09 | 35959879.19 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133819E+10 | 0.238887E+09 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323348E+09 | 0.236141E+09 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350012E+09 | 0.135865E+09 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531023E+09 | 0.138314E+09 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577230E+09 | 0.130436E+09 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906534E+09 | 75551456.25 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.882825E+09 | 60860956.49 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121055E+10 | 49558440.07 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133826E+10 | 39025423.13 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109262E+10 | 34545147.66 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116695E+10 | 45964605.53 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687120E+09 | 95186951.37 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450182E+09 | 0.139315E+09 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.951665E+10 | 0.118076E+10 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323348E+09 | 34545147.66 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133826E+10 | 0.236141E+09 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341114E+09 | 0.407443E+09 |
February | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.368698E+09 | 0.255029E+09 |
March | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.564099E+09 | 0.284793E+09 |
April | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.615733E+09 | 0.270827E+09 |
May | 0.932542E+09 | 0.366414E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.968401E+09 | 0.169842E+09 |
June | 0.914724E+09 | 0.357797E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.959468E+09 | 0.141890E+09 |
July | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131285E+10 | 0.121669E+09 |
August | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144568E+10 | 98029387.52 |
September | 0.901896E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118548E+10 | 85444072.06 |
October | 0.918158E+09 | 0.362278E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124047E+10 | 0.107282E+09 |
November | 0.884402E+09 | 0.351592E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.744672E+09 | 0.202691E+09 |
December | 0.919713E+09 | 0.360209E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.477906E+09 | 0.273367E+09 |
Annual Sum or Average | 0.109410E+11 | 0.429321E+11 | 0.963059E+10 | 0.102246E+11 | 0.241831E+10 | ||||
Minimum of Months | 0.835938E+09 | 0.328152E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341114E+09 | 85444072.06 |
Maximum of Months | 0.946926E+09 | 0.370550E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144568E+10 | 0.407443E+09 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 8262.19 | 01-JAN-10:09 | 1348.26 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2655.96 | 06-JAN-13:00 | 2255.15 | 25-JAN-12:10 |
February | 2159.72 | 03-FEB-13:09 | 8262.19 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2401.09 | 25-FEB-13:00 | 1108.46 | 06-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 8262.19 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3011.31 | 29-MAR-13:00 | 839.64 | 03-MAR-15:00 |
April | 2159.72 | 01-APR-12:09 | 8262.19 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3033.96 | 09-APR-14:00 | 969.46 | 27-APR-06:00 |
May | 2159.72 | 05-MAY-12:09 | 8262.19 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3600.60 | 17-MAY-13:00 | 556.39 | 31-MAY-04:00 |
June | 2159.72 | 02-JUN-12:09 | 8262.19 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3382.32 | 29-JUN-11:10 | 393.74 | 13-JUN-05:00 |
July | 2159.72 | 01-JUL-12:09 | 8262.19 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4060.86 | 09-JUL-12:00 | 413.87 | 13-JUL-06:00 |
August | 2159.72 | 04-AUG-12:09 | 8262.19 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4332.55 | 11-AUG-14:00 | 336.74 | 13-AUG-03:00 |
September | 2159.72 | 01-SEP-12:09 | 8262.19 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4726.15 | 03-SEP-13:00 | 363.43 | 30-SEP-06:00 |
October | 2159.72 | 01-OCT-12:09 | 8262.19 | 01-OCT-09:09 | 1348.26 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4567.82 | 01-OCT-13:00 | 361.87 | 18-OCT-01:00 |
November | 2159.72 | 03-NOV-12:09 | 8262.19 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3419.13 | 04-NOV-13:00 | 1124.23 | 25-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 8262.19 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3270.27 | 13-DEC-14:00 | 1021.56 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2401.09 | 336.74 | |||||
Maximum of Months | 2159.72 | 8262.19 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 4726.15 | 2255.15 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 4606.69 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.05 | 06-JAN-13:00 | 1256.98 | 25-JAN-12:10 |
February | 1079.86 | 03-FEB-13:09 | 4606.69 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.52 | 25-FEB-13:00 | 611.99 | 06-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 4606.69 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.17 | 29-MAR-13:00 | 464.76 | 03-MAR-15:00 |
April | 1079.86 | 01-APR-12:09 | 4606.69 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.26 | 09-APR-14:00 | 470.32 | 11-APR-14:00 |
May | 1079.86 | 05-MAY-12:09 | 4606.69 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.26 | 17-MAY-13:00 | 173.59 | 31-MAY-04:00 |
June | 1079.86 | 02-JUN-12:09 | 4606.69 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.31 | 29-JUN-11:10 | 121.61 | 13-JUN-05:00 |
July | 1079.86 | 01-JUL-12:09 | 4606.69 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.03 | 09-JUL-12:00 | 127.34 | 13-JUL-06:00 |
August | 1079.86 | 04-AUG-12:09 | 4606.69 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.03 | 11-AUG-14:00 | 99.49 | 13-AUG-03:00 |
September | 1079.86 | 01-SEP-12:09 | 4606.69 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.82 | 03-SEP-13:00 | 110.73 | 30-SEP-06:00 |
October | 1079.86 | 01-OCT-12:09 | 4606.69 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.92 | 01-OCT-13:00 | 166.71 | 19-OCT-07:03 |
November | 1079.86 | 03-NOV-12:09 | 4606.69 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.02 | 04-NOV-13:00 | 615.82 | 25-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 4606.69 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.37 | 13-DEC-14:00 | 573.59 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.52 | 99.49 | |||||
Maximum of Months | 1079.86 | 4606.69 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.82 | 1256.98 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.05 | 06-JAN-13:00 | 1346.26 | 15-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.55 | 25-FEB-13:00 | 1043.97 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.16 | 29-MAR-13:00 | 984.50 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.24 | 09-APR-14:00 | 773.99 | 16-APR-17:00 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.25 | 17-MAY-13:00 | 890.17 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.30 | 29-JUN-11:10 | 316.58 | 25-JUN-17:00 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.03 | 09-JUL-12:00 | 176.75 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2391.99 | 11-AUG-14:00 | 386.81 | 06-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 03-SEP-13:00 | 317.55 | 24-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.88 | 01-OCT-13:00 | 830.81 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.02 | 04-NOV-13:00 | 963.43 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.35 | 13-DEC-14:00 | 1152.58 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.55 | 176.75 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 1346.26 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.05 | 06-JAN-13:00 | 1343.18 | 15-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.55 | 25-FEB-13:00 | 1042.47 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.16 | 29-MAR-13:00 | 984.55 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.23 | 09-APR-14:00 | 774.66 | 16-APR-17:00 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.25 | 17-MAY-13:00 | 894.10 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.30 | 29-JUN-11:10 | 322.20 | 25-JUN-17:00 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.03 | 09-JUL-12:00 | 178.80 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2391.99 | 11-AUG-14:00 | 393.91 | 06-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 03-SEP-13:00 | 327.50 | 24-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.88 | 01-OCT-13:00 | 834.09 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.01 | 04-NOV-13:00 | 962.53 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.35 | 13-DEC-14:00 | 1151.73 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.55 | 178.80 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 1343.18 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 4250.44 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.04 | 06-JAN-13:00 | 1326.93 | 15-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 4250.44 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.54 | 25-FEB-13:00 | 1026.40 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 4250.44 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.16 | 29-MAR-13:00 | 969.40 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 4250.44 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.23 | 09-APR-14:00 | 758.95 | 16-APR-17:00 |
May | 1079.86 | 06-MAY-12:09 | 4250.44 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.24 | 17-MAY-13:00 | 880.73 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 4250.44 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.30 | 29-JUN-11:10 | 310.19 | 25-JUN-17:00 |
July | 1079.86 | 01-JUL-12:09 | 4250.44 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.03 | 09-JUL-12:00 | 173.83 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 4250.44 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2391.98 | 11-AUG-14:00 | 381.11 | 06-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 4250.44 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 03-SEP-13:00 | 314.85 | 24-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 4250.44 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.87 | 01-OCT-13:00 | 819.86 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 4250.44 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.01 | 04-NOV-13:00 | 947.43 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 4250.44 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.35 | 13-DEC-14:00 | 1136.18 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.54 | 173.83 | |||||
Maximum of Months | 1079.86 | 4250.44 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 1326.93 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 6064.13 | 01-JAN-11:09 | 1348.26 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2597.41 | 06-JAN-13:00 | 2209.60 | 15-JAN-18:00 |
February | 2879.63 | 04-FEB-15:09 | 6064.13 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2359.27 | 25-FEB-13:00 | 1688.16 | 12-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 6064.13 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2916.82 | 29-MAR-13:00 | 1600.96 | 05-MAR-18:00 |
April | 2879.63 | 01-APR-14:09 | 6064.13 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2932.13 | 09-APR-14:00 | 1234.85 | 16-APR-17:00 |
May | 2879.63 | 06-MAY-14:09 | 6064.13 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3464.53 | 17-MAY-13:00 | 1462.17 | 14-MAY-17:00 |
June | 2879.63 | 03-JUN-14:09 | 6064.13 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3246.04 | 29-JUN-11:10 | 466.16 | 25-JUN-17:00 |
July | 2879.63 | 01-JUL-14:09 | 6064.13 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3942.21 | 09-JUL-12:00 | 295.51 | 22-JUL-18:10 |
August | 2879.63 | 05-AUG-14:09 | 6064.13 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4205.92 | 11-AUG-14:00 | 598.94 | 06-AUG-17:00 |
September | 2879.63 | 02-SEP-14:09 | 6064.13 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4525.81 | 03-SEP-13:00 | 488.97 | 24-SEP-17:00 |
October | 2879.63 | 07-OCT-14:09 | 6064.13 | 01-OCT-10:09 | 1348.26 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4434.30 | 01-OCT-13:00 | 1345.25 | 22-OCT-17:00 |
November | 2879.63 | 04-NOV-14:09 | 6064.13 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3267.27 | 04-NOV-13:00 | 1554.34 | 26-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 6064.13 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3182.00 | 13-DEC-14:00 | 1878.07 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2359.27 | 295.51 | |||||
Maximum of Months | 2879.63 | 6064.13 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 4525.81 | 2209.60 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.07 | 06-JAN-13:00 | 1256.98 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.57 | 25-FEB-13:00 | 941.99 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.19 | 29-MAR-13:00 | 889.46 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.24 | 09-APR-14:00 | 680.24 | 16-APR-17:00 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.28 | 17-MAY-13:00 | 807.75 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.35 | 29-JUN-11:10 | 234.66 | 25-JUN-17:00 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.02 | 09-JUL-12:00 | 145.99 | 22-JUL-18:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.00 | 11-AUG-14:00 | 301.80 | 06-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 03-SEP-13:00 | 234.63 | 24-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.88 | 01-OCT-13:00 | 749.12 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.01 | 04-NOV-13:00 | 867.60 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.38 | 13-DEC-14:00 | 1052.24 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.57 | 145.99 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 1256.98 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.07 | 06-JAN-13:00 | 1256.98 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.57 | 25-FEB-13:00 | 934.76 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.19 | 29-MAR-13:00 | 882.80 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.24 | 09-APR-14:00 | 674.34 | 16-APR-17:00 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.28 | 17-MAY-13:00 | 802.01 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.35 | 29-JUN-11:10 | 228.34 | 25-JUN-17:00 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.02 | 09-JUL-12:00 | 143.92 | 22-JUL-18:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2391.99 | 11-AUG-14:00 | 294.98 | 06-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 03-SEP-13:00 | 227.73 | 24-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.88 | 01-OCT-13:00 | 743.64 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.01 | 04-NOV-13:00 | 861.34 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.38 | 13-DEC-14:00 | 1045.67 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.57 | 143.92 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.78 | 1256.98 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.07 | 06-JAN-13:00 | 1256.98 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.56 | 25-FEB-13:00 | 924.00 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1658.18 | 29-MAR-13:00 | 875.75 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1666.24 | 09-APR-14:00 | 666.10 | 16-APR-17:00 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1967.28 | 17-MAY-13:00 | 798.10 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1842.36 | 29-JUN-11:10 | 226.47 | 25-JUN-17:00 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2242.02 | 09-JUL-12:00 | 143.18 | 22-JUL-18:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2391.99 | 11-AUG-14:00 | 294.70 | 06-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.79 | 03-SEP-13:00 | 227.16 | 24-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2521.88 | 01-OCT-13:00 | 739.06 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.01 | 04-NOV-13:00 | 853.49 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1810.38 | 13-DEC-14:00 | 1038.85 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.56 | 143.18 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2567.79 | 1256.98 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 3032.07 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1537.60 | 06-JAN-13:00 | 1304.95 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 3032.07 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1386.47 | 25-FEB-13:00 | 974.93 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 3032.07 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1752.61 | 29-MAR-13:00 | 955.18 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 3032.07 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1767.89 | 09-APR-14:00 | 759.10 | 16-APR-17:00 |
May | 1439.81 | 06-MAY-14:09 | 3032.07 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2103.23 | 17-MAY-13:00 | 893.82 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 3032.07 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1978.55 | 29-JUN-11:10 | 320.09 | 25-JUN-17:00 |
July | 1439.81 | 01-JUL-14:09 | 3032.07 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2360.57 | 09-JUL-12:00 | 280.02 | 22-JUL-18:10 |
August | 1439.81 | 05-AUG-14:09 | 3032.07 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2518.41 | 11-AUG-14:00 | 402.02 | 06-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 3032.07 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2767.82 | 03-SEP-13:00 | 344.20 | 30-SEP-18:10 |
October | 1439.81 | 07-OCT-14:09 | 3032.07 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2655.16 | 01-OCT-13:00 | 841.04 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 3032.07 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2004.68 | 04-NOV-13:00 | 919.29 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 3032.07 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1898.57 | 13-DEC-14:00 | 1097.35 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1386.47 | 280.02 | |||||
Maximum of Months | 1439.81 | 3032.07 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 2767.82 | 1304.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 38789.80 | 21-JAN-08:62 | 0.00 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 261.49 |
February | 32219.26 | 04-FEB-08:62 | 0.00 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 202.54 |
March | 35500.87 | 19-MAR-07:02 | 1079.86 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 257.84 |
April | 36853.67 | 30-APR-07:02 | 899.88 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.46 |
May | 37201.10 | 02-MAY-07:02 | 899.88 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157.78 |
June | 34299.63 | 04-JUN-07:01 | 1259.84 | 3043.97 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 |
July | 32697.74 | 08-JUL-07:02 | 0.00 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 6.22 | 0.00 |
August | 33221.33 | 24-AUG-07:02 | 1079.86 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 140.81 |
September | 33002.10 | 18-SEP-07:02 | 1079.86 | 2609.11 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.85 |
October | 35171.77 | 26-OCT-07:02 | 899.88 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 230.12 |
November | 36936.96 | 26-NOV-08:62 | 899.88 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 276.70 |
December | 39342.18 | 25-DEC-08:62 | 899.88 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 238.27 |
Annual Sum or Average | |||||||||||
Minimum of Months | 32219.26 | 0.00 | 2174.26 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39342.18 | 1259.84 | 3043.97 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 6.22 | 276.70 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 21176.01 | 21-JAN-08:62 | 0.00 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.63 |
February | 18967.21 | 04-FEB-08:62 | 0.00 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.45 |
March | 19896.12 | 19-MAR-07:02 | 539.93 | 1454.74 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.77 |
April | 20543.78 | 30-APR-07:02 | 449.94 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.85 |
May | 20590.37 | 02-MAY-07:02 | 449.94 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.49 |
June | 19309.34 | 04-JUN-07:01 | 629.92 | 1697.20 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.08 |
July | 18686.68 | 08-JUL-07:02 | 0.00 | 1454.74 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 0.00 |
August | 19037.85 | 24-AUG-07:02 | 539.93 | 1454.74 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.39 |
September | 19187.93 | 25-SEP-07:01 | 629.92 | 1697.20 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.65 |
October | 20043.43 | 26-OCT-07:02 | 449.94 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.36 |
November | 20501.36 | 26-NOV-08:62 | 449.94 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.41 |
December | 21288.38 | 25-DEC-08:62 | 449.94 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 125.28 |
Annual Sum or Average | |||||||||||
Minimum of Months | 18686.68 | 0.00 | 1212.29 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 21288.38 | 629.92 | 1697.20 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 144.41 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 19496.80 | 21-JAN-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.76 |
February | 18374.39 | 01-FEB-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.53 |
March | 18641.89 | 24-MAR-06:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 |
April | 19093.56 | 30-APR-07:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.92 |
May | 18514.23 | 02-MAY-06:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.93 |
June | 17867.42 | 04-JUN-07:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.89 |
July | 16789.76 | 08-JUL-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.38 |
August | 17141.98 | 24-AUG-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.90 |
September | 17388.47 | 19-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 |
October | 17423.16 | 19-OCT-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.76 |
November | 18518.08 | 26-NOV-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.31 |
December | 20490.24 | 25-DEC-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.88 |
Annual Sum or Average | |||||||||||
Minimum of Months | 16789.76 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 | |
Maximum of Months | 20490.24 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 19470.65 | 22-JAN-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 |
February | 18318.18 | 01-FEB-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.53 |
March | 18499.59 | 24-MAR-06:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 |
April | 19116.64 | 30-APR-07:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.48 |
May | 18550.53 | 02-MAY-06:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.95 |
June | 17928.67 | 04-JUN-07:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.27 |
July | 16847.81 | 08-JUL-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.54 |
August | 17201.05 | 24-AUG-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.99 |
September | 17465.82 | 19-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.49 |
October | 17469.64 | 19-OCT-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 |
November | 18544.64 | 26-NOV-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.02 |
December | 20519.15 | 25-DEC-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.49 |
Annual Sum or Average | |||||||||||
Minimum of Months | 16847.81 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.49 | |
Maximum of Months | 20519.15 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 19275.53 | 22-JAN-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 173.02 |
February | 17120.10 | 03-FEB-07:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.86 |
March | 18149.02 | 19-MAR-07:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.26 |
April | 18914.00 | 30-APR-07:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.91 |
May | 18351.80 | 02-MAY-06:03 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.45 |
June | 17731.22 | 04-JUN-07:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.28 |
July | 16650.40 | 04-JUL-07:01 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.56 |
August | 16996.26 | 24-AUG-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.61 |
September | 17270.83 | 19-SEP-06:02 | 0.00 | 1342.24 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.41 |
October | 17259.81 | 19-OCT-06:02 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.35 |
November | 18354.98 | 26-NOV-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.41 |
December | 20328.55 | 25-DEC-08:62 | 0.00 | 1118.54 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.98 |
Annual Sum or Average | |||||||||||
Minimum of Months | 16650.40 | 0.00 | 894.83 | 149.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.41 | |
Maximum of Months | 20328.55 | 0.00 | 1565.95 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 173.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 36844.73 | 21-JAN-08:62 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 223.95 |
February | 30074.08 | 13-FEB-08:62 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.32 |
March | 32333.76 | 19-MAR-08:62 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.54 |
April | 34098.83 | 06-APR-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.84 |
May | 34395.08 | 02-MAY-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.86 |
June | 31468.93 | 04-JUN-08:61 | 0.00 | 2234.15 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.63 |
July | 30768.35 | 18-JUL-07:01 | 0.00 | 2234.15 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 39.34 | 0.00 |
August | 31057.32 | 24-AUG-07:02 | 0.00 | 1914.99 | 449.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.34 |
September | 31555.49 | 19-SEP-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.08 |
October | 32077.93 | 26-OCT-07:02 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 223.02 |
November | 33670.34 | 15-NOV-08:61 | 0.00 | 2234.15 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.08 |
December | 37395.55 | 20-DEC-08:62 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.35 |
Annual Sum or Average | |||||||||||
Minimum of Months | 30074.08 | 0.00 | 1595.82 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 37395.55 | 0.00 | 2234.15 | 524.32 | 0.00 | 0.00 | 0.00 | 0.00 | 39.34 | 288.35 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18995.08 | 21-JAN-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.71 |
February | 15508.23 | 13-FEB-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.36 |
March | 16664.33 | 19-MAR-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.66 |
April | 17584.85 | 06-APR-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.00 |
May | 17753.63 | 02-MAY-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.34 |
June | 16193.11 | 04-JUN-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.45 |
July | 15863.95 | 18-JUL-07:01 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 26.75 | 0.00 |
August | 16013.55 | 24-AUG-07:02 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.93 |
September | 16296.59 | 19-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.04 |
October | 16548.97 | 26-OCT-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.05 |
November | 17360.59 | 15-NOV-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.24 |
December | 19276.36 | 20-DEC-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.03 |
Annual Sum or Average | |||||||||||
Minimum of Months | 15508.23 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19276.36 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 26.75 | 153.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18879.36 | 21-JAN-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.10 |
February | 15402.76 | 13-FEB-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 |
March | 16563.26 | 19-MAR-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.14 |
April | 17477.21 | 06-APR-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.49 |
May | 17642.24 | 02-MAY-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.16 |
June | 16088.25 | 04-JUN-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.89 |
July | 15765.56 | 18-JUL-07:01 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 28.09 | 0.00 |
August | 15909.21 | 24-AUG-07:02 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.67 |
September | 16189.40 | 19-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.83 |
October | 16436.21 | 26-OCT-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.82 |
November | 17250.76 | 15-NOV-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.50 |
December | 19160.99 | 20-DEC-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.30 |
Annual Sum or Average | |||||||||||
Minimum of Months | 15402.76 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19160.99 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 28.09 | 151.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 17801.88 | 21-JAN-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.88 |
February | 15301.64 | 13-FEB-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.03 |
March | 16498.73 | 19-MAR-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.13 |
April | 17405.88 | 06-APR-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.14 |
May | 17566.02 | 02-MAY-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.25 |
June | 16032.42 | 04-JUN-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.33 |
July | 15708.23 | 18-JUL-07:01 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 31.55 | 0.00 |
August | 15867.78 | 24-AUG-07:02 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.18 |
September | 16142.26 | 19-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.02 |
October | 16384.55 | 26-OCT-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.16 |
November | 17165.42 | 15-NOV-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.10 |
December | 19082.42 | 20-DEC-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.74 |
Annual Sum or Average | |||||||||||
Minimum of Months | 15301.64 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19082.42 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 31.55 | 145.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18447.92 | 22-JAN-09:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.08 |
February | 14658.89 | 26-FEB-09:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.58 |
March | 17684.09 | 19-MAR-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.26 |
April | 18430.54 | 30-APR-08:62 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 16.10 | 0.00 |
May | 17492.72 | 30-MAY-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.90 |
June | 17318.68 | 04-JUN-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.40 |
July | 16623.79 | 04-JUL-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 0.00 |
August | 16044.09 | 07-AUG-07:01 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 12.51 | 0.00 |
September | 16189.65 | 19-SEP-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.37 |
October | 16933.58 | 26-OCT-07:02 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 113.61 |
November | 18409.64 | 15-NOV-08:61 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.94 |
December | 20460.97 | 24-DEC-09:02 | 0.00 | 957.49 | 224.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.12 |
Annual Sum or Average | |||||||||||
Minimum of Months | 14658.89 | 0.00 | 797.91 | 187.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20460.97 | 0.00 | 1117.08 | 262.16 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 145.08 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.155964E+12 | 136093.50 | 04-JAN-13:50 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 0.146059E+12 | 136192.57 | 20-FEB-15:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 0.161844E+12 | 133478.87 | 13-MAR-15:39 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 0.154180E+12 | 130102.47 | 24-APR-14:30 | 0.00 | 0.00 | 01-APR-00:10 |
May | 0.170026E+12 | 134056.86 | 13-MAY-13:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 0.167466E+12 | 134898.13 | 29-JUN-11:50 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.177912E+12 | 142207.62 | 17-JUL-14:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.182658E+12 | 147730.70 | 19-AUG-12:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.175421E+12 | 148921.07 | 03-SEP-12:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.179289E+12 | 145873.17 | 01-OCT-13:09 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.165015E+12 | 139218.70 | 06-NOV-14:20 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 0.163054E+12 | 134708.62 | 13-DEC-12:50 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.199889E+13 | 0.00 | ||||
Minimum of Months | 0.146059E+12 | 130102.47 | 0.00 | 0.00 | ||
Maximum of Months | 0.182658E+12 | 148921.07 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.595337E+11 | 0.103357E+11 | 0.108804E+11 | 0.00 | 0.234094E+11 | 0.00 | 0.00 | 0.467724E+11 | 0.00 | 0.00 | 0.00 | 0.503251E+10 | 0.00 |
February | 0.539017E+11 | 0.902052E+10 | 0.985143E+10 | 0.00 | 0.212088E+11 | 0.00 | 0.00 | 0.475312E+11 | 0.00 | 0.00 | 0.00 | 0.454538E+10 | 0.00 |
March | 0.604219E+11 | 0.952800E+10 | 0.110523E+11 | 0.00 | 0.238026E+11 | 0.00 | 0.00 | 0.519949E+11 | 0.00 | 0.00 | 0.00 | 0.504393E+10 | 0.00 |
April | 0.577706E+11 | 0.874140E+10 | 0.105581E+11 | 0.00 | 0.227226E+11 | 0.00 | 0.00 | 0.495538E+11 | 0.00 | 0.00 | 0.00 | 0.483338E+10 | 0.00 |
May | 0.599558E+11 | 0.863991E+10 | 0.109629E+11 | 0.00 | 0.236299E+11 | 0.00 | 0.00 | 0.618677E+11 | 0.00 | 0.00 | 0.00 | 0.496986E+10 | 0.00 |
June | 0.584038E+11 | 0.817471E+10 | 0.106818E+11 | 0.00 | 0.230297E+11 | 0.00 | 0.00 | 0.623718E+11 | 0.00 | 0.00 | 0.00 | 0.480388E+10 | 0.00 |
July | 0.593665E+11 | 0.850035E+10 | 0.108460E+11 | 0.00 | 0.233915E+11 | 0.00 | 0.00 | 0.708891E+11 | 0.00 | 0.00 | 0.00 | 0.491887E+10 | 0.00 |
August | 0.603780E+11 | 0.886405E+10 | 0.110454E+11 | 0.00 | 0.238367E+11 | 0.00 | 0.00 | 0.735747E+11 | 0.00 | 0.00 | 0.00 | 0.495949E+10 | 0.00 |
September | 0.578145E+11 | 0.902475E+10 | 0.105649E+11 | 0.00 | 0.227984E+11 | 0.00 | 0.00 | 0.704242E+11 | 0.00 | 0.00 | 0.00 | 0.479399E+10 | 0.00 |
October | 0.595337E+11 | 0.978597E+10 | 0.108804E+11 | 0.00 | 0.234686E+11 | 0.00 | 0.00 | 0.706452E+11 | 0.00 | 0.00 | 0.00 | 0.497498E+10 | 0.00 |
November | 0.576828E+11 | 0.989170E+10 | 0.105443E+11 | 0.00 | 0.227247E+11 | 0.00 | 0.00 | 0.593290E+11 | 0.00 | 0.00 | 0.00 | 0.484250E+10 | 0.00 |
December | 0.594104E+11 | 0.104457E+11 | 0.108529E+11 | 0.00 | 0.233577E+11 | 0.00 | 0.00 | 0.539660E+11 | 0.00 | 0.00 | 0.00 | 0.502106E+10 | 0.00 |
Annual Sum or Average | 0.704173E+12 | 0.110953E+12 | 0.128721E+12 | 0.277380E+12 | 0.00 | 0.718920E+12 | 0.587398E+11 | ||||||
Minimum of Months | 0.539017E+11 | 0.817471E+10 | 0.985143E+10 | 0.00 | 0.212088E+11 | 0.00 | 0.00 | 0.467724E+11 | 0.00 | 0.00 | 0.00 | 0.454538E+10 | 0.00 |
Maximum of Months | 0.604219E+11 | 0.104457E+11 | 0.110523E+11 | 0.00 | 0.238367E+11 | 0.00 | 0.00 | 0.735747E+11 | 0.00 | 0.00 | 0.00 | 0.504393E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 43812.60 | 01-JAN-11:09 | 7048.38 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:09 | 0.00 | 16071.65 | 04-JAN-17:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 43812.60 | 01-FEB-10:09 | 7048.38 | 01-FEB-00:10 | 8089.53 | 01-FEB-10:09 | 0.00 | 16071.65 | 08-FEB-09:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 43812.60 | 01-MAR-10:09 | 7048.38 | 01-MAR-00:10 | 8089.53 | 01-MAR-10:09 | 0.00 | 16071.65 | 02-MAR-14:50 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 43812.60 | 01-APR-09:09 | 7048.38 | 01-APR-00:10 | 8089.53 | 01-APR-09:09 | 0.00 | 16071.65 | 18-APR-08:20 | 0.00 | 0.00 | 01-APR-00:10 |
May | 43812.60 | 01-MAY-09:09 | 7048.38 | 01-MAY-00:10 | 8089.53 | 01-MAY-09:09 | 0.00 | 16071.65 | 04-MAY-07:49 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 43812.60 | 01-JUN-09:09 | 7048.38 | 01-JUN-00:10 | 8089.53 | 01-JUN-09:09 | 0.00 | 16071.65 | 02-JUN-07:49 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 43812.60 | 01-JUL-09:09 | 7048.38 | 01-JUL-00:10 | 8089.53 | 01-JUL-09:09 | 0.00 | 16071.65 | 06-JUL-10:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 43812.60 | 01-AUG-09:09 | 7048.38 | 01-AUG-00:10 | 8089.53 | 01-AUG-09:09 | 0.00 | 16071.65 | 08-AUG-09:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 43812.60 | 01-SEP-09:09 | 7048.38 | 01-SEP-00:10 | 8089.53 | 01-SEP-09:09 | 0.00 | 16071.65 | 06-SEP-18:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 43812.60 | 01-OCT-10:09 | 7048.38 | 01-OCT-00:10 | 8089.53 | 01-OCT-10:09 | 0.00 | 16071.65 | 10-OCT-14:39 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 43812.60 | 01-NOV-09:09 | 7048.38 | 01-NOV-00:10 | 8089.53 | 01-NOV-09:09 | 0.00 | 16071.65 | 09-NOV-08:30 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 43812.60 | 01-DEC-10:09 | 7048.38 | 01-DEC-00:10 | 8089.53 | 01-DEC-10:09 | 0.00 | 16071.65 | 06-DEC-08:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 43812.60 | 7048.38 | 8089.53 | 0.00 | 16071.65 | 0.00 | 0.00 | |||||
Maximum of Months | 43812.60 | 7048.38 | 8089.53 | 0.00 | 16071.65 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 59743.14 | 01-JAN-13:39 | 0.00 | 0.00 | 0.00 | 11790.50 | 11-JAN-13:30 | 0.00 |
February | 62205.46 | 19-FEB-13:00 | 0.00 | 0.00 | 0.00 | 10675.92 | 15-FEB-14:30 | 0.00 |
March | 60993.00 | 13-MAR-14:09 | 0.00 | 0.00 | 0.00 | 9641.40 | 28-MAR-15:39 | 0.00 |
April | 57625.19 | 24-APR-13:00 | 0.00 | 0.00 | 0.00 | 9294.50 | 16-APR-11:09 | 0.00 |
May | 62753.58 | 13-MAY-13:00 | 0.00 | 0.00 | 0.00 | 9651.81 | 16-MAY-11:09 | 0.00 |
June | 61218.36 | 29-JUN-12:00 | 0.00 | 0.00 | 0.00 | 8842.67 | 12-JUN-12:30 | 0.00 |
July | 68541.42 | 15-JUL-13:00 | 0.00 | 0.00 | 0.00 | 10647.78 | 14-JUL-12:50 | 0.00 |
August | 72495.87 | 19-AUG-14:00 | 0.00 | 0.00 | 0.00 | 9662.64 | 23-AUG-13:30 | 0.00 |
September | 75578.07 | 03-SEP-13:30 | 0.00 | 0.00 | 0.00 | 7555.07 | 21-SEP-12:50 | 0.00 |
October | 72888.45 | 11-OCT-12:00 | 0.00 | 0.00 | 0.00 | 7543.75 | 26-OCT-11:30 | 0.00 |
November | 66433.16 | 06-NOV-13:00 | 0.00 | 0.00 | 0.00 | 7556.89 | 09-NOV-14:00 | 0.00 |
December | 63364.80 | 13-DEC-13:00 | 0.00 | 0.00 | 0.00 | 9675.65 | 26-DEC-13:20 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 57625.19 | 0.00 | 0.00 | 0.00 | 7543.75 | 0.00 | ||
Maximum of Months | 75578.07 | 0.00 | 0.00 | 0.00 | 11790.50 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 136093.50 | 04-JAN-13:50 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 59260.91 | 0.00 |
February | 136192.57 | 20-FEB-15:09 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 60694.20 | 0.00 |
March | 133478.87 | 13-MAR-15:39 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 60074.83 | 0.00 |
April | 130102.47 | 24-APR-14:30 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 56695.53 | 0.00 |
May | 134056.86 | 13-MAY-13:00 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 62753.58 | 0.00 |
June | 134898.13 | 29-JUN-11:50 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 59384.58 | 0.00 |
July | 142207.62 | 17-JUL-14:30 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 66692.20 | 0.00 |
August | 147730.70 | 19-AUG-12:00 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 72206.30 | 0.00 |
September | 148921.07 | 03-SEP-12:00 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 75527.48 | 0.00 |
October | 145873.17 | 01-OCT-13:09 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 72478.94 | 0.00 |
November | 139218.70 | 06-NOV-14:20 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 65800.78 | 0.00 |
December | 134708.62 | 13-DEC-12:50 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 61300.37 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 130102.47 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 56695.53 | 0.00 | |
Maximum of Months | 148921.07 | 43812.60 | 8089.53 | 0.00 | 0.00 | 16071.65 | 0.00 | 0.00 | 75527.48 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.17 | 24.46 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.17 | 24.45 |
Annual Sum or Average | 0.00 | 0.00 | 0.33 | 24.46 | 0.33 | 24.46 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.17 | 24.46 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.51 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.52 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.50 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.67 | 24.51 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.52 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.56 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.51 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.00 | 24.53 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.56 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.55 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.47 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.33 | 24.53 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.55 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.58 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.55 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.59 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.51 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.61 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.50 | 24.55 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.61 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.55 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.53 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.55 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.54 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.00 | 24.54 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.55 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.54 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.52 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.64 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.49 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.53 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.83 | 24.55 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.64 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.55 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.62 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.46 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.67 | 24.54 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.62 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.46 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.73 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.66 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.61 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.49 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.50 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.00 | 24.58 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.73 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 23.96 | 487.17 | 23.89 | 1.33 | 23.96 |
February | 16.17 | 23.89 | 443.00 | 23.89 | 16.17 | 23.89 |
March | 7.00 | 23.90 | 488.17 | 23.89 | 7.00 | 23.90 |
April | 0.00 | 0.00 | 479.33 | 23.89 | 0.00 | 0.00 |
May | 2.67 | 23.96 | 496.00 | 23.89 | 2.67 | 23.96 |
June | 3.67 | 24.06 | 480.00 | 23.89 | 3.67 | 24.06 |
July | 13.33 | 23.99 | 496.00 | 23.89 | 13.33 | 23.99 |
August | 10.50 | 24.02 | 496.00 | 23.89 | 10.50 | 24.02 |
September | 14.17 | 23.96 | 480.00 | 23.89 | 14.17 | 23.96 |
October | 4.33 | 24.03 | 496.00 | 23.89 | 4.33 | 24.03 |
November | 6.83 | 23.99 | 480.00 | 23.89 | 6.83 | 23.99 |
December | 3.33 | 23.98 | 495.50 | 23.89 | 3.33 | 23.98 |
Annual Sum or Average | 83.33 | 23.97 | 5817.17 | 23.89 | 83.33 | 23.97 |
Minimum of Months | 0.00 | 0.00 | 443.00 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 16.17 | 24.06 | 496.00 | 23.89 | 16.17 | 24.06 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 483.00 | 23.89 | 0.00 | 0.00 |
February | 10.00 | 23.89 | 438.83 | 23.89 | 10.00 | 23.89 |
March | 4.33 | 23.89 | 481.83 | 23.89 | 4.33 | 23.89 |
April | 0.00 | 0.00 | 475.67 | 23.89 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 496.00 | 23.89 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 480.00 | 23.89 | 0.00 | 0.00 |
July | 4.00 | 23.97 | 496.00 | 23.89 | 4.00 | 23.97 |
August | 0.50 | 24.16 | 496.00 | 23.89 | 0.50 | 24.16 |
September | 3.33 | 24.04 | 480.00 | 23.89 | 3.33 | 24.04 |
October | 0.00 | 0.00 | 496.00 | 23.89 | 0.00 | 0.00 |
November | 0.33 | 24.09 | 479.50 | 23.89 | 0.33 | 24.09 |
December | 0.67 | 24.07 | 492.67 | 23.89 | 0.67 | 24.07 |
Annual Sum or Average | 23.17 | 23.94 | 5795.50 | 23.89 | 23.17 | 23.94 |
Minimum of Months | 0.00 | 0.00 | 438.83 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 10.00 | 24.16 | 496.00 | 23.89 | 10.00 | 24.16 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.67 | 26.94 | 368.00 | 24.06 | 1.67 | 26.94 |
February | 19.67 | 24.73 | 333.17 | 24.07 | 19.67 | 24.73 |
March | 8.50 | 25.16 | 376.50 | 24.08 | 8.50 | 25.16 |
April | 2.50 | 27.53 | 360.00 | 24.09 | 2.50 | 27.53 |
May | 7.83 | 27.44 | 375.00 | 24.11 | 7.83 | 27.44 |
June | 7.33 | 27.80 | 366.00 | 24.12 | 7.33 | 27.80 |
July | 13.33 | 27.13 | 369.00 | 24.14 | 13.33 | 27.13 |
August | 10.33 | 27.88 | 379.00 | 24.13 | 10.33 | 27.88 |
September | 17.00 | 27.06 | 360.00 | 24.15 | 17.00 | 27.06 |
October | 11.00 | 27.62 | 371.00 | 24.13 | 11.00 | 27.62 |
November | 3.83 | 27.62 | 360.00 | 24.09 | 3.83 | 27.62 |
December | 3.50 | 27.03 | 369.00 | 24.08 | 3.50 | 27.03 |
Annual Sum or Average | 106.50 | 26.73 | 4386.67 | 24.10 | 106.50 | 26.73 |
Minimum of Months | 1.67 | 24.73 | 333.17 | 24.06 | 1.67 | 24.73 |
Maximum of Months | 19.67 | 27.88 | 379.00 | 24.15 | 19.67 | 27.88 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.67 | 26.94 | 368.00 | 24.06 | 1.67 | 26.94 |
February | 20.17 | 24.71 | 333.17 | 24.07 | 20.17 | 24.71 |
March | 8.50 | 25.16 | 376.50 | 24.08 | 8.50 | 25.16 |
April | 2.50 | 27.54 | 360.00 | 24.09 | 2.50 | 27.54 |
May | 7.83 | 27.44 | 375.00 | 24.11 | 7.83 | 27.44 |
June | 7.33 | 27.81 | 366.00 | 24.12 | 7.33 | 27.81 |
July | 13.50 | 27.10 | 369.00 | 24.14 | 13.50 | 27.10 |
August | 10.33 | 27.89 | 379.00 | 24.13 | 10.33 | 27.89 |
September | 16.67 | 27.16 | 360.00 | 24.15 | 16.67 | 27.16 |
October | 10.83 | 27.69 | 371.00 | 24.13 | 10.83 | 27.69 |
November | 4.00 | 27.61 | 360.00 | 24.09 | 4.00 | 27.61 |
December | 3.50 | 27.03 | 369.00 | 24.08 | 3.50 | 27.03 |
Annual Sum or Average | 106.83 | 26.74 | 4386.67 | 24.10 | 106.83 | 26.74 |
Minimum of Months | 1.67 | 24.71 | 333.17 | 24.06 | 1.67 | 24.71 |
Maximum of Months | 20.17 | 27.89 | 379.00 | 24.15 | 20.17 | 27.89 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 26.85 | 367.83 | 24.06 | 1.50 | 26.85 |
February | 23.00 | 24.59 | 333.17 | 24.07 | 23.00 | 24.59 |
March | 8.33 | 25.03 | 375.83 | 24.08 | 8.33 | 25.03 |
April | 2.17 | 27.54 | 359.83 | 24.08 | 2.17 | 27.54 |
May | 7.17 | 27.41 | 375.00 | 24.11 | 7.17 | 27.41 |
June | 7.00 | 27.77 | 366.00 | 24.11 | 7.00 | 27.77 |
July | 13.83 | 26.98 | 369.00 | 24.13 | 13.83 | 26.98 |
August | 10.33 | 27.83 | 379.00 | 24.12 | 10.33 | 27.83 |
September | 17.17 | 26.99 | 360.00 | 24.14 | 17.17 | 26.99 |
October | 10.33 | 27.65 | 371.00 | 24.13 | 10.33 | 27.65 |
November | 3.17 | 27.67 | 360.00 | 24.09 | 3.17 | 27.67 |
December | 3.17 | 26.94 | 369.00 | 24.08 | 3.17 | 26.94 |
Annual Sum or Average | 107.17 | 26.57 | 4385.67 | 24.10 | 107.17 | 26.57 |
Minimum of Months | 1.50 | 24.59 | 333.17 | 24.06 | 1.50 | 24.59 |
Maximum of Months | 23.00 | 27.83 | 379.00 | 24.14 | 23.00 | 27.83 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 26.37 | 334.83 | 23.95 | 1.50 | 26.37 |
February | 33.67 | 24.20 | 305.33 | 23.95 | 33.67 | 24.20 |
March | 10.17 | 24.62 | 346.00 | 23.95 | 10.17 | 24.62 |
April | 1.50 | 27.39 | 328.83 | 23.96 | 1.50 | 27.39 |
May | 4.50 | 27.31 | 344.00 | 23.97 | 4.50 | 27.31 |
June | 3.83 | 27.84 | 336.00 | 23.96 | 3.83 | 27.84 |
July | 11.67 | 26.19 | 338.00 | 24.00 | 11.67 | 26.19 |
August | 5.00 | 27.94 | 348.00 | 23.97 | 5.00 | 27.94 |
September | 14.00 | 26.03 | 330.00 | 24.00 | 14.00 | 26.03 |
October | 6.67 | 27.37 | 340.00 | 23.99 | 6.67 | 27.37 |
November | 1.83 | 27.64 | 330.00 | 23.96 | 1.83 | 27.64 |
December | 3.17 | 26.42 | 337.00 | 23.96 | 3.17 | 26.42 |
Annual Sum or Average | 97.50 | 25.66 | 4018.00 | 23.97 | 97.50 | 25.66 |
Minimum of Months | 1.50 | 24.20 | 305.33 | 23.95 | 1.50 | 24.20 |
Maximum of Months | 33.67 | 27.94 | 348.00 | 24.00 | 33.67 | 27.94 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 26.10 | 330.50 | 23.95 | 1.50 | 26.10 |
February | 34.33 | 24.20 | 302.50 | 23.95 | 34.33 | 24.20 |
March | 9.83 | 24.47 | 342.83 | 23.95 | 9.83 | 24.47 |
April | 1.17 | 27.28 | 328.17 | 23.96 | 1.17 | 27.28 |
May | 3.67 | 27.08 | 344.00 | 23.97 | 3.67 | 27.08 |
June | 3.17 | 27.82 | 336.00 | 23.96 | 3.17 | 27.82 |
July | 11.67 | 26.01 | 338.00 | 24.00 | 11.67 | 26.01 |
August | 4.83 | 27.90 | 348.00 | 23.97 | 4.83 | 27.90 |
September | 16.00 | 25.71 | 330.00 | 24.00 | 16.00 | 25.71 |
October | 6.17 | 27.40 | 340.00 | 23.98 | 6.17 | 27.40 |
November | 1.83 | 27.30 | 330.00 | 23.95 | 1.83 | 27.30 |
December | 4.17 | 25.85 | 335.67 | 23.96 | 4.17 | 25.85 |
Annual Sum or Average | 98.33 | 25.49 | 4005.67 | 23.97 | 98.33 | 25.49 |
Minimum of Months | 1.17 | 24.20 | 302.50 | 23.95 | 1.17 | 24.20 |
Maximum of Months | 34.33 | 27.90 | 348.00 | 24.00 | 34.33 | 27.90 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 26.08 | 330.17 | 23.95 | 1.50 | 26.08 |
February | 34.83 | 24.18 | 302.33 | 23.95 | 34.83 | 24.18 |
March | 10.00 | 24.43 | 342.33 | 23.95 | 10.00 | 24.43 |
April | 1.17 | 27.26 | 328.17 | 23.96 | 1.17 | 27.26 |
May | 3.50 | 27.06 | 344.00 | 23.96 | 3.50 | 27.06 |
June | 3.00 | 27.84 | 336.00 | 23.96 | 3.00 | 27.84 |
July | 11.83 | 25.97 | 338.00 | 24.00 | 11.83 | 25.97 |
August | 4.67 | 27.91 | 348.00 | 23.97 | 4.67 | 27.91 |
September | 16.33 | 25.62 | 330.00 | 24.00 | 16.33 | 25.62 |
October | 6.33 | 27.29 | 340.00 | 23.98 | 6.33 | 27.29 |
November | 1.67 | 27.30 | 330.00 | 23.95 | 1.67 | 27.30 |
December | 4.83 | 25.66 | 335.50 | 23.96 | 4.83 | 25.66 |
Annual Sum or Average | 99.67 | 25.42 | 4004.50 | 23.97 | 99.67 | 25.42 |
Minimum of Months | 1.17 | 24.18 | 302.33 | 23.95 | 1.17 | 24.18 |
Maximum of Months | 34.83 | 27.91 | 348.00 | 24.00 | 34.83 | 27.91 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 26.05 | 330.17 | 23.94 | 1.50 | 26.05 |
February | 36.17 | 24.16 | 302.00 | 23.95 | 36.17 | 24.16 |
March | 10.33 | 24.41 | 341.83 | 23.95 | 10.33 | 24.41 |
April | 1.17 | 27.24 | 328.00 | 23.96 | 1.17 | 27.24 |
May | 3.83 | 26.78 | 344.00 | 23.96 | 3.83 | 26.78 |
June | 3.00 | 27.83 | 336.00 | 23.96 | 3.00 | 27.83 |
July | 12.00 | 25.94 | 338.00 | 24.00 | 12.00 | 25.94 |
August | 4.83 | 27.88 | 348.00 | 23.96 | 4.83 | 27.88 |
September | 17.00 | 25.59 | 330.00 | 24.00 | 17.00 | 25.59 |
October | 6.33 | 27.28 | 340.00 | 23.98 | 6.33 | 27.28 |
November | 1.67 | 27.29 | 330.00 | 23.95 | 1.67 | 27.29 |
December | 4.83 | 25.53 | 335.50 | 23.96 | 4.83 | 25.53 |
Annual Sum or Average | 102.67 | 25.38 | 4003.50 | 23.97 | 102.67 | 25.38 |
Minimum of Months | 1.17 | 24.16 | 302.00 | 23.94 | 1.17 | 24.16 |
Maximum of Months | 36.17 | 27.88 | 348.00 | 24.00 | 36.17 | 27.88 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.00 | 25.88 | 330.17 | 23.95 | 2.00 | 25.88 |
February | 42.00 | 24.17 | 301.83 | 23.96 | 42.00 | 24.17 |
March | 13.50 | 24.49 | 342.67 | 23.95 | 13.50 | 24.49 |
April | 1.67 | 27.50 | 328.00 | 23.97 | 1.67 | 27.50 |
May | 6.00 | 26.99 | 344.00 | 23.97 | 6.00 | 26.99 |
June | 4.67 | 27.73 | 336.00 | 23.97 | 4.67 | 27.73 |
July | 12.50 | 26.23 | 338.00 | 24.00 | 12.50 | 26.23 |
August | 5.67 | 27.58 | 348.00 | 23.97 | 5.67 | 27.58 |
September | 18.17 | 25.64 | 330.00 | 24.00 | 18.17 | 25.64 |
October | 7.83 | 27.12 | 340.00 | 23.99 | 7.83 | 27.12 |
November | 3.00 | 26.62 | 330.00 | 23.96 | 3.00 | 26.62 |
December | 3.67 | 26.34 | 335.50 | 23.96 | 3.67 | 26.34 |
Annual Sum or Average | 120.67 | 25.47 | 4004.17 | 23.97 | 120.67 | 25.47 |
Minimum of Months | 1.67 | 24.17 | 301.83 | 23.95 | 1.67 | 24.17 |
Maximum of Months | 42.00 | 27.73 | 348.00 | 24.00 | 42.00 | 27.73 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.89914 | 49.64364 | 0.58827 | 12.37740 |
February | 448.00000 | 23.89731 | 54.05171 | 0.62593 | 13.36749 |
March | 496.00000 | 23.89616 | 51.01299 | 0.60761 | 12.88192 |
April | 480.00000 | 23.89861 | 50.12275 | 0.60207 | 12.69394 |
May | 496.00000 | 23.90443 | 52.51997 | -0.1818 | 5.83693 |
June | 480.00000 | 23.90679 | 53.05487 | -0.1635 | 5.69856 |
July | 496.00000 | 23.90922 | 54.37207 | -0.1345 | 5.52912 |
August | 496.00000 | 23.90942 | 54.26431 | -0.1323 | 5.52317 |
September | 480.00000 | 23.90718 | 55.52613 | -0.1143 | 5.45369 |
October | 496.00000 | 23.90537 | 54.60738 | 0.67376 | 14.63762 |
November | 480.00000 | 23.90759 | 53.62590 | 0.64962 | 13.97392 |
December | 496.00000 | 23.90334 | 52.18679 | 0.62223 | 13.24941 |
Annual Sum or Average | 5840.00000 | 23.90375 | 52.90455 | 0.30160 | 10.08218 |
Minimum of Months | 448.00000 | 23.89616 | 49.64364 | -0.1818 | 5.45369 |
Maximum of Months | 496.00000 | 23.90942 | 55.52613 | 0.67376 | 14.63762 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.90094 | 47.99821 | 0.56916 | 11.90778 |
February | 448.00000 | 23.89910 | 51.86514 | 0.59933 | 12.68802 |
March | 496.00000 | 23.89795 | 49.32245 | 0.58302 | 12.26076 |
April | 480.00000 | 23.90043 | 48.54319 | 0.57766 | 12.08980 |
May | 496.00000 | 23.90613 | 50.85142 | -0.2174 | 6.13236 |
June | 480.00000 | 23.90793 | 51.56659 | -0.2021 | 5.99258 |
July | 496.00000 | 23.91003 | 52.78480 | -0.1778 | 5.81316 |
August | 496.00000 | 23.90992 | 52.70040 | -0.1773 | 5.81224 |
September | 480.00000 | 23.90759 | 53.88632 | -0.1628 | 5.72963 |
October | 496.00000 | 23.90643 | 52.73300 | 0.64198 | 13.76282 |
November | 480.00000 | 23.90906 | 51.82117 | 0.62143 | 13.22043 |
December | 496.00000 | 23.90492 | 50.36530 | 0.59850 | 12.63977 |
Annual Sum or Average | 5840.00000 | 23.90507 | 51.19497 | 0.26913 | 9.82037 |
Minimum of Months | 448.00000 | 23.89795 | 47.99821 | -0.2174 | 5.72963 |
Maximum of Months | 496.00000 | 23.91003 | 53.88632 | 0.64198 | 13.76282 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.02109 | 49.44168 | 0.61280 | 13.04775 |
February | 336.00000 | 24.02936 | 54.06649 | 0.64990 | 14.09549 |
March | 379.00000 | 24.03773 | 50.96357 | 0.62948 | 13.54545 |
April | 360.00000 | 24.04164 | 50.02682 | 0.62362 | 13.35472 |
May | 375.00000 | 24.06310 | 52.31203 | -0.1511 | 5.90908 |
June | 366.00000 | 24.06422 | 52.91019 | -0.1373 | 5.81511 |
July | 369.00000 | 24.07906 | 54.06147 | -0.1071 | 5.75606 |
August | 379.00000 | 24.07143 | 53.90792 | -0.1099 | 5.74239 |
September | 360.00000 | 24.08778 | 55.33198 | -0.0889 | 5.80977 |
October | 371.00000 | 24.07701 | 54.34022 | 0.70010 | 15.57956 |
November | 360.00000 | 24.04769 | 53.41663 | 0.67154 | 14.66984 |
December | 369.00000 | 24.03883 | 52.02527 | 0.64681 | 13.98644 |
Annual Sum or Average | 4395.00000 | 24.05508 | 52.71969 | 0.32511 | 10.57486 |
Minimum of Months | 336.00000 | 24.02109 | 49.44168 | -0.1511 | 5.74239 |
Maximum of Months | 379.00000 | 24.08778 | 55.33198 | 0.70010 | 15.57956 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.02058 | 49.46427 | 0.61227 | 13.03387 |
February | 336.00000 | 24.02897 | 54.08206 | 0.64964 | 14.08809 |
March | 379.00000 | 24.03741 | 50.96727 | 0.62946 | 13.54409 |
April | 360.00000 | 24.04131 | 50.03303 | 0.62351 | 13.35153 |
May | 375.00000 | 24.06305 | 52.29741 | -0.1504 | 5.90568 |
June | 366.00000 | 24.06419 | 52.89328 | -0.1365 | 5.81168 |
July | 369.00000 | 24.07923 | 54.02458 | -0.1056 | 5.75231 |
August | 379.00000 | 24.07154 | 53.87613 | -0.1085 | 5.73863 |
September | 360.00000 | 24.08804 | 55.28036 | -0.0870 | 5.80750 |
October | 371.00000 | 24.07717 | 54.30057 | 0.70107 | 15.60979 |
November | 360.00000 | 24.04751 | 53.41536 | 0.67170 | 14.67503 |
December | 369.00000 | 24.03851 | 52.03528 | 0.64665 | 13.98238 |
Annual Sum or Average | 4395.00000 | 24.05496 | 52.70828 | 0.32565 | 10.57397 |
Minimum of Months | 336.00000 | 24.02058 | 49.46427 | -0.1504 | 5.73863 |
Maximum of Months | 379.00000 | 24.08804 | 55.28036 | 0.70107 | 15.60979 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.01746 | 49.63007 | 0.60846 | 12.93114 |
February | 336.00000 | 24.02592 | 54.29822 | 0.64612 | 13.98695 |
March | 379.00000 | 24.03437 | 51.15151 | 0.62566 | 13.43791 |
April | 360.00000 | 24.03827 | 50.20288 | 0.61971 | 13.24556 |
May | 375.00000 | 24.06016 | 52.45418 | -0.1554 | 5.92274 |
June | 366.00000 | 24.06147 | 53.04749 | -0.1413 | 5.82396 |
July | 369.00000 | 24.07667 | 54.16226 | -0.1098 | 5.75501 |
August | 379.00000 | 24.06894 | 54.02241 | -0.1130 | 5.74313 |
September | 360.00000 | 24.08545 | 55.43136 | -0.0912 | 5.80628 |
October | 371.00000 | 24.07442 | 54.45574 | 0.69815 | 15.51554 |
November | 360.00000 | 24.04464 | 53.57986 | 0.66860 | 14.58058 |
December | 369.00000 | 24.03546 | 52.20847 | 0.64323 | 13.88281 |
Annual Sum or Average | 4395.00000 | 24.05210 | 52.87247 | 0.32172 | 10.51867 |
Minimum of Months | 336.00000 | 24.01746 | 49.63007 | -0.1554 | 5.74313 |
Maximum of Months | 379.00000 | 24.08545 | 55.43136 | 0.69815 | 15.51554 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.93275 | 50.68977 | 0.59034 | 12.43740 |
February | 308.00000 | 23.94008 | 55.51221 | 0.63081 | 13.52153 |
March | 348.00000 | 23.93430 | 52.24385 | 0.60811 | 12.91349 |
April | 330.00000 | 23.94756 | 51.21926 | 0.60224 | 12.73369 |
May | 344.00000 | 23.94880 | 53.45761 | -0.1845 | 5.96330 |
June | 336.00000 | 23.94656 | 54.11001 | -0.1700 | 5.84084 |
July | 338.00000 | 23.97218 | 55.16935 | -0.1327 | 5.70878 |
August | 348.00000 | 23.94868 | 54.97210 | -0.1406 | 5.69933 |
September | 330.00000 | 23.97302 | 56.44757 | -0.1132 | 5.71572 |
October | 340.00000 | 23.96354 | 55.36079 | 0.68167 | 14.95160 |
November | 330.00000 | 23.94034 | 54.67000 | 0.65002 | 13.99680 |
December | 338.00000 | 23.94222 | 53.33509 | 0.62470 | 13.32964 |
Annual Sum or Average | 4030.00000 | 23.94917 | 53.91616 | 0.30051 | 10.20106 |
Minimum of Months | 308.00000 | 23.93275 | 50.68977 | -0.1845 | 5.69933 |
Maximum of Months | 348.00000 | 23.97302 | 56.44757 | 0.68167 | 14.95160 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.93242 | 50.79917 | 0.56904 | 11.90923 |
February | 308.00000 | 23.93967 | 55.67970 | 0.60893 | 12.94318 |
March | 348.00000 | 23.93382 | 52.37443 | 0.58549 | 12.33529 |
April | 330.00000 | 23.94703 | 51.32960 | 0.57946 | 12.16042 |
May | 344.00000 | 23.94821 | 53.59419 | -0.2193 | 6.24640 |
June | 336.00000 | 23.94591 | 54.25319 | -0.2059 | 6.11112 |
July | 338.00000 | 23.97175 | 55.31311 | -0.1701 | 5.93660 |
August | 348.00000 | 23.94823 | 55.10488 | -0.1780 | 5.93704 |
September | 330.00000 | 23.97220 | 56.61993 | -0.1514 | 5.90990 |
October | 340.00000 | 23.96308 | 55.50787 | 0.65618 | 14.22488 |
November | 330.00000 | 23.94000 | 54.81486 | 0.62637 | 13.35094 |
December | 338.00000 | 23.94172 | 53.47209 | 0.60239 | 12.74475 |
Annual Sum or Average | 4030.00000 | 23.94867 | 54.05550 | 0.27181 | 9.95441 |
Minimum of Months | 308.00000 | 23.93242 | 50.79917 | -0.2193 | 5.90990 |
Maximum of Months | 348.00000 | 23.97220 | 56.61993 | 0.65618 | 14.22488 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.93200 | 50.86846 | 0.56682 | 11.85512 |
February | 308.00000 | 23.93926 | 55.77230 | 0.60678 | 12.88703 |
March | 348.00000 | 23.93349 | 52.44988 | 0.58327 | 12.27943 |
April | 330.00000 | 23.94661 | 51.39711 | 0.57724 | 12.10517 |
May | 344.00000 | 23.94784 | 53.66079 | -0.2224 | 6.27293 |
June | 336.00000 | 23.94558 | 54.32051 | -0.2090 | 6.13564 |
July | 338.00000 | 23.97133 | 55.37749 | -0.1732 | 5.95522 |
August | 348.00000 | 23.94793 | 55.16635 | -0.1810 | 5.95678 |
September | 330.00000 | 23.97178 | 56.69059 | -0.1544 | 5.92547 |
October | 340.00000 | 23.96268 | 55.57297 | 0.65415 | 14.16716 |
November | 330.00000 | 23.93964 | 54.88871 | 0.62429 | 13.29466 |
December | 338.00000 | 23.94127 | 53.54606 | 0.60025 | 12.68939 |
Annual Sum or Average | 4030.00000 | 23.94829 | 54.12600 | 0.26927 | 9.93094 |
Minimum of Months | 308.00000 | 23.93200 | 50.86846 | -0.2224 | 5.92547 |
Maximum of Months | 348.00000 | 23.97178 | 56.69059 | 0.65415 | 14.16716 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.93150 | 50.96884 | 0.56659 | 11.84996 |
February | 308.00000 | 23.93876 | 55.91154 | 0.60641 | 12.87843 |
March | 348.00000 | 23.93317 | 52.56400 | 0.58307 | 12.27545 |
April | 330.00000 | 23.94621 | 51.47701 | 0.57764 | 12.11500 |
May | 344.00000 | 23.94765 | 53.70328 | -0.2208 | 6.25799 |
June | 336.00000 | 23.94540 | 54.35675 | -0.2071 | 6.11931 |
July | 338.00000 | 23.97117 | 55.39508 | -0.1706 | 5.93715 |
August | 348.00000 | 23.94789 | 55.17316 | -0.1780 | 5.93586 |
September | 330.00000 | 23.97162 | 56.71964 | -0.1522 | 5.91225 |
October | 340.00000 | 23.96254 | 55.59935 | 0.65588 | 14.21555 |
November | 330.00000 | 23.93933 | 54.95695 | 0.62499 | 13.31342 |
December | 338.00000 | 23.94079 | 53.63119 | 0.60051 | 12.69638 |
Annual Sum or Average | 4030.00000 | 23.94801 | 54.18755 | 0.27042 | 9.92947 |
Minimum of Months | 308.00000 | 23.93150 | 50.96884 | -0.2208 | 5.91225 |
Maximum of Months | 348.00000 | 23.97162 | 56.71964 | 0.65588 | 14.21555 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.93362 | 50.91407 | 0.58698 | 12.37050 |
February | 308.00000 | 23.94138 | 55.99071 | 0.62372 | 13.35124 |
March | 348.00000 | 23.93612 | 52.69741 | 0.60411 | 12.82580 |
April | 330.00000 | 23.94993 | 51.30160 | 0.60493 | 12.81439 |
May | 344.00000 | 23.95183 | 53.28922 | -0.1717 | 5.89786 |
June | 336.00000 | 23.94921 | 53.97589 | -0.1577 | 5.78371 |
July | 338.00000 | 23.97716 | 54.93553 | -0.1150 | 5.65983 |
August | 348.00000 | 23.95248 | 54.63165 | -0.1183 | 5.62349 |
September | 330.00000 | 23.97727 | 56.45037 | -0.1027 | 5.71714 |
October | 340.00000 | 23.96787 | 55.11947 | 0.69307 | 15.30849 |
November | 330.00000 | 23.94229 | 54.81117 | 0.65023 | 14.01853 |
December | 338.00000 | 23.94343 | 53.49517 | 0.62228 | 13.28012 |
Annual Sum or Average | 4030.00000 | 23.95190 | 53.94786 | 0.30673 | 10.18829 |
Minimum of Months | 308.00000 | 23.93362 | 50.91407 | -0.1717 | 5.62349 |
Maximum of Months | 348.00000 | 23.97727 | 56.45037 | 0.69307 | 15.30849 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.324611E+11 | 0.981244E+10 | 497.87 | 0.239877E+11 | 0.847334E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:03 | 57221.54 | 31-JAN-08:62 | 42856.13 | 21-JAN-08:62 | 24545.32 | 31-JAN-08:62 | 13936.47 | 02-JAN-08:62 | 0.00 | 01-JAN-00:03 |
February | 0.337832E+11 | 0.100408E+11 | 451.83 | 0.228746E+11 | 0.109086E+11 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 59200.10 | 18-FEB-08:62 | 36999.65 | 13-FEB-08:62 | 30943.60 | 17-FEB-08:04 | 14160.68 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.359792E+11 | 0.108797E+11 | 499.25 | 0.260941E+11 | 0.988513E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 57546.51 | 03-MAR-08:62 | 39101.63 | 19-MAR-07:02 | 27206.81 | 03-MAR-08:62 | 13902.12 | 15-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.344289E+11 | 0.104970E+11 | 483.36 | 0.255498E+11 | 0.887916E+10 | 0.00 | 1.00 | 05-APR-07:03 | 0.00 | 01-APR-00:03 | 56204.94 | 25-APR-07:02 | 41175.21 | 30-APR-07:02 | 20514.70 | 15-APR-07:03 | 13967.79 | 25-APR-07:02 | 0.00 | 01-APR-00:03 |
May | 0.422413E+11 | 0.128882E+11 | 502.69 | 0.302250E+11 | 0.120163E+11 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 58118.52 | 10-MAY-07:02 | 41572.70 | 02-MAY-07:02 | 26403.62 | 10-MAY-07:03 | 14211.05 | 09-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.427808E+11 | 0.130096E+11 | 488.00 | 0.303813E+11 | 0.123995E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 57661.32 | 14-JUN-07:02 | 38679.14 | 04-JUN-07:01 | 24387.50 | 14-JUN-07:03 | 14445.28 | 21-JUN-07:01 | 0.00 | 01-JUN-00:10 |
July | 0.490270E+11 | 0.149381E+11 | 504.21 | 0.342161E+11 | 0.148109E+11 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 59393.32 | 20-JUL-07:01 | 37724.71 | 08-JUL-07:02 | 29817.45 | 20-JUL-07:04 | 14441.29 | 20-JUL-07:04 | 0.00 | 01-JUL-00:03 |
August | 0.496584E+11 | 0.152088E+11 | 503.34 | 0.348493E+11 | 0.148091E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 58384.24 | 08-AUG-07:01 | 37325.50 | 24-AUG-07:02 | 26426.88 | 08-AUG-07:04 | 14398.53 | 27-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.497109E+11 | 0.149629E+11 | 489.34 | 0.337442E+11 | 0.159667E+11 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 58917.58 | 30-SEP-07:02 | 37313.63 | 19-SEP-07:02 | 29152.69 | 30-SEP-07:03 | 14579.98 | 03-SEP-07:01 | 0.00 | 01-SEP-00:10 |
October | 0.483728E+11 | 0.147069E+11 | 502.84 | 0.335357E+11 | 0.148371E+11 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 58126.23 | 13-OCT-07:02 | 38922.93 | 26-OCT-07:02 | 25624.34 | 13-OCT-07:03 | 14345.14 | 07-OCT-07:01 | 0.00 | 01-OCT-00:03 |
November | 0.410804E+11 | 0.123743E+11 | 485.43 | 0.286549E+11 | 0.124255E+11 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 58266.85 | 01-NOV-07:02 | 40893.45 | 26-NOV-08:62 | 26476.50 | 01-NOV-07:03 | 14403.49 | 06-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.379478E+11 | 0.113939E+11 | 502.97 | 0.267459E+11 | 0.112020E+11 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-01:03 | 58501.80 | 03-DEC-08:61 | 43580.71 | 25-DEC-08:62 | 26586.72 | 03-DEC-08:13 | 14367.52 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.497472E+12 | 0.150713E+12 | 5911.14 | 0.350859E+12 | 0.146613E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.324611E+11 | 0.981244E+10 | 451.83 | 0.228746E+11 | 0.847334E+10 | 0.00 | 1.00 | 0.00 | 56204.94 | 36999.65 | 20514.70 | 13902.12 | 0.00 | |||||||
Maximum of Months | 0.497109E+11 | 0.152088E+11 | 504.21 | 0.348493E+11 | 0.159667E+11 | 0.00 | 1.00 | 0.00 | 59393.32 | 43580.71 | 30943.60 | 14579.98 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.168845E+11 | 0.487191E+10 | 498.15 | 0.128576E+11 | 0.402691E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:03 | 29421.25 | 31-JAN-08:62 | 23507.99 | 21-JAN-08:62 | 10030.61 | 31-JAN-08:62 | 6847.78 | 02-JAN-08:62 | 0.00 | 01-JAN-00:03 |
February | 0.172284E+11 | 0.489930E+10 | 451.78 | 0.120820E+11 | 0.514643E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 30275.74 | 17-FEB-08:62 | 21554.92 | 03-FEB-08:62 | 13026.33 | 17-FEB-08:62 | 6984.92 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.183797E+11 | 0.531447E+10 | 499.21 | 0.137142E+11 | 0.466550E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 29533.28 | 03-MAR-08:62 | 22000.51 | 06-MAR-08:62 | 11183.90 | 03-MAR-08:62 | 6822.28 | 15-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.174901E+11 | 0.510202E+10 | 483.51 | 0.133423E+11 | 0.414777E+10 | 0.00 | 1.00 | 05-APR-07:03 | 0.00 | 01-APR-00:03 | 29047.38 | 17-APR-07:02 | 23037.44 | 30-APR-07:02 | 8698.10 | 14-APR-07:03 | 6834.03 | 25-APR-07:02 | 0.00 | 01-APR-00:03 |
May | 0.211681E+11 | 0.618778E+10 | 502.47 | 0.155786E+11 | 0.558952E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 29763.61 | 10-MAY-07:02 | 23097.82 | 02-MAY-07:02 | 10897.73 | 10-MAY-07:03 | 6983.00 | 09-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.212662E+11 | 0.619892E+10 | 487.56 | 0.155047E+11 | 0.576148E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 29739.77 | 14-JUN-07:02 | 22083.73 | 06-JUN-07:02 | 10731.45 | 14-JUN-07:03 | 7123.52 | 21-JUN-07:01 | 0.00 | 01-JUN-00:10 |
July | 0.241287E+11 | 0.706480E+10 | 503.82 | 0.173148E+11 | 0.681393E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 30539.72 | 20-JUL-07:01 | 21500.37 | 08-JUL-07:02 | 13461.18 | 20-JUL-07:04 | 7140.31 | 20-JUL-07:01 | 0.00 | 01-JUL-00:03 |
August | 0.244662E+11 | 0.719491E+10 | 502.54 | 0.176321E+11 | 0.683412E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 30056.28 | 08-AUG-07:01 | 21387.23 | 24-AUG-07:02 | 11540.09 | 08-AUG-07:03 | 7093.16 | 27-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.242556E+11 | 0.702637E+10 | 489.02 | 0.169425E+11 | 0.731314E+10 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 30224.21 | 30-SEP-07:02 | 21584.21 | 25-SEP-07:01 | 12550.61 | 30-SEP-07:03 | 7194.01 | 03-SEP-07:01 | 0.00 | 01-SEP-00:10 |
October | 0.240474E+11 | 0.701501E+10 | 502.48 | 0.171744E+11 | 0.687302E+10 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 29848.70 | 13-OCT-07:02 | 22273.92 | 26-OCT-07:02 | 10987.63 | 13-OCT-07:03 | 7065.84 | 07-OCT-07:01 | 0.00 | 01-OCT-00:03 |
November | 0.206452E+11 | 0.595542E+10 | 485.47 | 0.148395E+11 | 0.580573E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 30028.41 | 01-NOV-07:02 | 22790.91 | 26-NOV-08:62 | 11710.63 | 01-NOV-07:03 | 7096.29 | 22-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.193106E+11 | 0.554744E+10 | 503.13 | 0.140581E+11 | 0.525241E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-01:03 | 30276.84 | 03-DEC-08:61 | 23712.01 | 25-DEC-08:62 | 12332.09 | 03-DEC-08:04 | 7098.19 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.249271E+12 | 0.723783E+11 | 5909.14 | 0.181041E+12 | 0.682299E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.168845E+11 | 0.487191E+10 | 451.78 | 0.120820E+11 | 0.402691E+10 | 0.00 | 1.00 | 0.00 | 29047.38 | 21387.23 | 8698.10 | 6822.28 | 0.00 | |||||||
Maximum of Months | 0.244662E+11 | 0.719491E+10 | 503.82 | 0.176321E+11 | 0.731314E+10 | 0.00 | 1.00 | 0.00 | 30539.72 | 23712.01 | 13461.18 | 7194.01 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.135531E+11 | 0.386344E+10 | 364.38 | 0.100850E+11 | 0.346808E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:03 | 30161.11 | 02-JAN-07:02 | 21813.60 | 21-JAN-07:03 | 12889.24 | 02-JAN-07:03 | 6856.27 | 02-JAN-07:02 | 0.00 | 01-JAN-00:03 |
February | 0.139345E+11 | 0.390656E+10 | 332.39 | 0.948507E+10 | 0.444947E+10 | 0.00 | 1.00 | 02-FEB-07:03 | 0.00 | 01-FEB-00:05 | 31182.24 | 18-FEB-07:02 | 20803.54 | 01-FEB-07:03 | 16641.26 | 18-FEB-07:03 | 6974.25 | 17-FEB-07:04 | 0.00 | 01-FEB-00:05 |
March | 0.149464E+11 | 0.427049E+10 | 373.86 | 0.108907E+11 | 0.405578E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:03 | 30631.32 | 13-MAR-06:02 | 21006.17 | 24-MAR-06:03 | 14599.00 | 13-MAR-06:03 | 6852.51 | 14-MAR-06:02 | 0.00 | 01-MAR-00:03 |
April | 0.140703E+11 | 0.405516E+10 | 355.91 | 0.104828E+11 | 0.358751E+10 | 0.00 | 1.00 | 01-APR-06:03 | 0.00 | 01-APR-00:03 | 30054.35 | 24-APR-06:02 | 21484.70 | 30-APR-07:02 | 12952.10 | 24-APR-06:02 | 6855.63 | 25-APR-06:02 | 0.00 | 01-APR-00:03 |
May | 0.174350E+11 | 0.502909E+10 | 373.36 | 0.125437E+11 | 0.489124E+10 | 0.00 | 1.00 | 01-MAY-06:02 | 0.00 | 01-MAY-00:10 | 30596.74 | 15-MAY-06:02 | 21145.27 | 02-MAY-06:03 | 14797.63 | 15-MAY-06:03 | 6961.72 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.176565E+11 | 0.506871E+10 | 364.99 | 0.125555E+11 | 0.510093E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 30186.82 | 18-JUN-07:01 | 20225.80 | 04-JUN-07:01 | 12378.09 | 09-JUN-06:02 | 7085.73 | 21-JUN-06:01 | 0.00 | 01-JUN-00:10 |
July | 0.198308E+11 | 0.571026E+10 | 368.23 | 0.138826E+11 | 0.594814E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:03 | 31103.26 | 23-JUL-07:01 | 19247.44 | 04-JUL-07:01 | 15234.90 | 23-JUL-07:05 | 7114.61 | 23-JUL-07:13 | 0.00 | 01-JUL-00:03 |
August | 0.205285E+11 | 0.594957E+10 | 378.26 | 0.144796E+11 | 0.604891E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 30815.42 | 20-AUG-07:01 | 19177.39 | 23-AUG-06:01 | 14395.57 | 20-AUG-07:04 | 7109.61 | 27-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.199159E+11 | 0.565615E+10 | 359.81 | 0.135425E+11 | 0.637335E+10 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:10 | 31293.85 | 25-SEP-06:01 | 19393.88 | 19-SEP-06:02 | 16474.50 | 25-SEP-06:03 | 7213.27 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.198580E+11 | 0.569954E+10 | 369.95 | 0.138513E+11 | 0.600665E+10 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 30661.93 | 01-OCT-07:01 | 19250.12 | 28-OCT-06:02 | 14880.57 | 10-OCT-06:03 | 7047.06 | 07-OCT-06:01 | 0.00 | 01-OCT-00:03 |
November | 0.170522E+11 | 0.484767E+10 | 358.45 | 0.119563E+11 | 0.509590E+10 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 30460.75 | 06-NOV-07:01 | 20676.38 | 26-NOV-08:62 | 13902.70 | 24-NOV-07:03 | 7065.58 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.156399E+11 | 0.442448E+10 | 366.11 | 0.110830E+11 | 0.455693E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 30701.19 | 03-DEC-08:61 | 22845.88 | 25-DEC-08:62 | 13921.68 | 03-DEC-08:13 | 7088.90 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.204421E+12 | 0.584811E+11 | 4365.69 | 0.144838E+12 | 0.595829E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.135531E+11 | 0.386344E+10 | 332.39 | 0.948507E+10 | 0.346808E+10 | 0.00 | 1.00 | 0.00 | 30054.35 | 19177.39 | 12378.09 | 6852.51 | 0.00 | |||||||
Maximum of Months | 0.205285E+11 | 0.594957E+10 | 378.26 | 0.144796E+11 | 0.637335E+10 | 0.00 | 1.00 | 0.00 | 31293.85 | 22845.88 | 16641.26 | 7213.27 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.135322E+11 | 0.385875E+10 | 364.22 | 0.100698E+11 | 0.346245E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:03 | 30217.22 | 02-JAN-07:02 | 21747.45 | 12-JAN-07:02 | 12887.92 | 02-JAN-07:03 | 6868.25 | 02-JAN-07:02 | 0.00 | 01-JAN-00:03 |
February | 0.139255E+11 | 0.390507E+10 | 332.26 | 0.947989E+10 | 0.444560E+10 | 0.00 | 1.00 | 02-FEB-07:03 | 0.00 | 01-FEB-00:05 | 31236.53 | 18-FEB-07:02 | 20750.41 | 01-FEB-07:03 | 16667.69 | 18-FEB-07:03 | 6986.15 | 17-FEB-07:04 | 0.00 | 01-FEB-00:05 |
March | 0.149493E+11 | 0.427219E+10 | 373.64 | 0.108949E+11 | 0.405444E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:03 | 30689.41 | 13-MAR-06:02 | 20859.67 | 24-MAR-06:03 | 14597.16 | 13-MAR-06:03 | 6864.49 | 14-MAR-06:02 | 0.00 | 01-MAR-00:03 |
April | 0.140695E+11 | 0.405581E+10 | 355.91 | 0.104837E+11 | 0.358575E+10 | 0.00 | 1.00 | 01-APR-06:03 | 0.00 | 01-APR-00:03 | 30108.21 | 24-APR-06:02 | 21519.28 | 30-APR-07:02 | 12960.74 | 24-APR-06:02 | 6867.55 | 25-APR-06:02 | 0.00 | 01-APR-00:03 |
May | 0.174640E+11 | 0.503785E+10 | 373.53 | 0.125697E+11 | 0.489436E+10 | 0.00 | 1.00 | 01-MAY-06:02 | 0.00 | 01-MAY-00:10 | 30655.40 | 15-MAY-06:02 | 21191.58 | 02-MAY-06:03 | 14787.90 | 15-MAY-06:03 | 6973.80 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.176892E+11 | 0.507815E+10 | 364.85 | 0.125846E+11 | 0.510457E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 30245.47 | 18-JUN-07:01 | 20290.63 | 04-JUN-07:01 | 12389.35 | 09-JUN-06:02 | 7097.99 | 21-JUN-06:01 | 0.00 | 01-JUN-00:10 |
July | 0.198899E+11 | 0.572666E+10 | 368.24 | 0.139334E+11 | 0.595652E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:03 | 31163.80 | 23-JUL-07:01 | 19325.77 | 04-JUL-07:01 | 15231.35 | 23-JUL-07:05 | 7126.76 | 23-JUL-07:13 | 0.00 | 01-JUL-00:03 |
August | 0.205825E+11 | 0.596480E+10 | 378.31 | 0.145263E+11 | 0.605620E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 30877.26 | 20-AUG-07:01 | 19243.06 | 23-AUG-06:01 | 14381.84 | 20-AUG-07:04 | 7121.74 | 27-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.199879E+11 | 0.567564E+10 | 359.74 | 0.136029E+11 | 0.638505E+10 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:10 | 31359.68 | 25-SEP-06:01 | 19471.67 | 19-SEP-06:02 | 16436.23 | 25-SEP-06:03 | 7225.66 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.199171E+11 | 0.571592E+10 | 369.99 | 0.139015E+11 | 0.601561E+10 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 30721.23 | 01-OCT-07:01 | 19305.99 | 28-OCT-06:02 | 14854.69 | 23-OCT-06:02 | 7059.22 | 07-OCT-06:01 | 0.00 | 01-OCT-00:03 |
November | 0.170653E+11 | 0.485206E+10 | 358.42 | 0.119693E+11 | 0.509593E+10 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 30524.34 | 06-NOV-07:01 | 20714.29 | 26-NOV-08:62 | 13891.51 | 24-NOV-07:03 | 7077.71 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.156364E+11 | 0.442447E+10 | 366.05 | 0.110822E+11 | 0.455416E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 30756.43 | 03-DEC-08:61 | 22885.17 | 25-DEC-08:62 | 13934.79 | 03-DEC-08:13 | 7100.99 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.204709E+12 | 0.585674E+11 | 4365.15 | 0.145098E+12 | 0.596106E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.135322E+11 | 0.385875E+10 | 332.26 | 0.947989E+10 | 0.346245E+10 | 0.00 | 1.00 | 0.00 | 30108.21 | 19243.06 | 12389.35 | 6864.49 | 0.00 | |||||||
Maximum of Months | 0.205825E+11 | 0.596480E+10 | 378.31 | 0.145263E+11 | 0.638505E+10 | 0.00 | 1.00 | 0.00 | 31359.68 | 22885.17 | 16667.69 | 7225.66 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.132830E+11 | 0.379243E+10 | 364.23 | 0.985924E+10 | 0.342373E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:03 | 30062.89 | 02-JAN-07:02 | 21534.17 | 12-JAN-07:02 | 12890.43 | 02-JAN-07:03 | 6835.10 | 02-JAN-07:02 | 0.00 | 01-JAN-00:03 |
February | 0.136866E+11 | 0.384209E+10 | 332.12 | 0.928669E+10 | 0.439989E+10 | 0.00 | 1.00 | 02-FEB-07:03 | 0.00 | 01-FEB-00:05 | 31075.94 | 18-FEB-07:02 | 19483.80 | 13-FEB-07:02 | 16696.61 | 18-FEB-07:03 | 6953.09 | 17-FEB-07:04 | 0.00 | 01-FEB-00:05 |
March | 0.146864E+11 | 0.420187E+10 | 373.31 | 0.106755E+11 | 0.401091E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:03 | 30531.91 | 13-MAR-06:02 | 20102.13 | 19-MAR-07:02 | 14605.00 | 13-MAR-06:03 | 6831.03 | 14-MAR-06:02 | 0.00 | 01-MAR-00:03 |
April | 0.138245E+11 | 0.398991E+10 | 355.42 | 0.102769E+11 | 0.354752E+10 | 0.00 | 1.00 | 03-APR-06:03 | 0.00 | 01-APR-00:03 | 29952.45 | 24-APR-06:02 | 21304.02 | 30-APR-07:02 | 12991.04 | 24-APR-06:02 | 6834.12 | 25-APR-06:02 | 0.00 | 01-APR-00:03 |
May | 0.172293E+11 | 0.497472E+10 | 373.59 | 0.123717E+11 | 0.485756E+10 | 0.00 | 1.00 | 01-MAY-06:02 | 0.00 | 01-MAY-00:10 | 30500.08 | 15-MAY-06:02 | 20978.88 | 02-MAY-06:03 | 14786.65 | 15-MAY-06:03 | 6940.27 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.174647E+11 | 0.501791E+10 | 364.71 | 0.123962E+11 | 0.506849E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 30087.05 | 18-JUN-07:01 | 20087.47 | 04-JUN-07:01 | 12444.94 | 09-JUN-06:02 | 7063.88 | 21-JUN-06:01 | 0.00 | 01-JUN-00:10 |
July | 0.196814E+11 | 0.567016E+10 | 367.93 | 0.137578E+11 | 0.592367E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:03 | 31001.55 | 23-JUL-07:01 | 19127.72 | 04-JUL-07:01 | 15245.29 | 23-JUL-07:05 | 7093.10 | 23-JUL-07:13 | 0.00 | 01-JUL-00:03 |
August | 0.203584E+11 | 0.590391E+10 | 378.18 | 0.143372E+11 | 0.602121E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 30717.76 | 20-AUG-07:01 | 19040.36 | 23-AUG-06:01 | 14384.44 | 20-AUG-07:04 | 7088.09 | 27-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.197809E+11 | 0.562027E+10 | 359.83 | 0.134306E+11 | 0.635034E+10 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:10 | 31202.21 | 25-SEP-06:01 | 19270.77 | 19-SEP-06:02 | 16420.34 | 25-SEP-06:03 | 7191.42 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.196937E+11 | 0.565572E+10 | 369.92 | 0.137141E+11 | 0.597965E+10 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 30564.19 | 10-OCT-06:01 | 19087.57 | 28-OCT-06:02 | 14863.18 | 23-OCT-06:02 | 7025.45 | 07-OCT-06:01 | 0.00 | 01-OCT-00:03 |
November | 0.168397E+11 | 0.479229E+10 | 358.48 | 0.117820E+11 | 0.505771E+10 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 30369.28 | 06-NOV-07:01 | 20512.98 | 26-NOV-08:62 | 13899.03 | 24-NOV-07:03 | 7043.82 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.153942E+11 | 0.436051E+10 | 365.96 | 0.108805E+11 | 0.451368E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 30594.89 | 03-DEC-08:61 | 22679.22 | 25-DEC-08:62 | 13951.61 | 03-DEC-08:13 | 7067.46 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.201923E+12 | 0.578218E+11 | 4363.68 | 0.142768E+12 | 0.591544E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.132830E+11 | 0.379243E+10 | 332.12 | 0.928669E+10 | 0.342373E+10 | 0.00 | 1.00 | 0.00 | 29952.45 | 19040.36 | 12444.94 | 6831.03 | 0.00 | |||||||
Maximum of Months | 0.203584E+11 | 0.590391E+10 | 378.18 | 0.143372E+11 | 0.635034E+10 | 0.00 | 1.00 | 0.00 | 31202.21 | 22679.22 | 16696.61 | 7191.42 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.228245E+11 | 0.692677E+10 | 355.12 | 0.165617E+11 | 0.626276E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 54501.61 | 02-JAN-08:62 | 40427.42 | 21-JAN-08:62 | 23370.74 | 02-JAN-08:03 | 13383.23 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 |
February | 0.237305E+11 | 0.706982E+10 | 323.15 | 0.156806E+11 | 0.804985E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 56004.48 | 18-FEB-08:62 | 34628.39 | 13-FEB-08:62 | 29605.37 | 18-FEB-08:03 | 13388.63 | 18-FEB-08:03 | 0.00 | 01-FEB-00:05 |
March | 0.255719E+11 | 0.777344E+10 | 365.17 | 0.181817E+11 | 0.739013E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 55253.23 | 13-MAR-07:02 | 36417.12 | 19-MAR-08:62 | 26956.92 | 13-MAR-07:03 | 13132.97 | 13-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.239020E+11 | 0.733083E+10 | 344.25 | 0.173994E+11 | 0.650258E+10 | 0.00 | 1.00 | 06-APR-07:02 | 0.00 | 01-APR-00:03 | 54322.63 | 24-APR-07:02 | 38769.56 | 30-APR-08:62 | 23958.11 | 24-APR-07:02 | 13266.45 | 09-APR-08:62 | 0.00 | 01-APR-00:03 |
May | 0.302572E+11 | 0.927039E+10 | 364.70 | 0.212937E+11 | 0.896349E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 55301.24 | 15-MAY-07:02 | 38210.54 | 02-MAY-07:02 | 26857.49 | 15-MAY-07:03 | 13596.74 | 14-MAY-08:61 | 0.00 | 01-MAY-00:10 |
June | 0.307100E+11 | 0.935582E+10 | 356.81 | 0.213502E+11 | 0.935984E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 54519.11 | 18-JUN-08:61 | 35463.49 | 04-JUN-08:61 | 22474.31 | 14-JUN-07:03 | 13684.12 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.347469E+11 | 0.106001E+11 | 357.02 | 0.238164E+11 | 0.109304E+11 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 56255.30 | 23-JUL-08:61 | 35689.17 | 04-JUL-08:61 | 27362.06 | 23-JUL-08:06 | 13772.62 | 23-JUL-08:13 | 0.00 | 01-JUL-00:03 |
August | 0.361615E+11 | 0.111124E+11 | 370.07 | 0.250034E+11 | 0.111581E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 55699.58 | 20-AUG-08:61 | 34852.27 | 23-AUG-07:02 | 25758.33 | 20-AUG-08:06 | 13910.17 | 27-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.349958E+11 | 0.105288E+11 | 349.76 | 0.232962E+11 | 0.116997E+11 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 56505.11 | 25-SEP-07:01 | 35480.47 | 19-SEP-07:02 | 30098.38 | 25-SEP-07:01 | 14036.41 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.349323E+11 | 0.106314E+11 | 359.89 | 0.238633E+11 | 0.110691E+11 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 55380.60 | 10-OCT-07:02 | 35309.99 | 26-OCT-07:02 | 27183.97 | 23-OCT-07:02 | 13797.96 | 08-OCT-08:03 | 0.00 | 01-OCT-00:03 |
November | 0.294646E+11 | 0.889097E+10 | 349.33 | 0.201630E+11 | 0.930166E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 55112.37 | 24-NOV-08:61 | 37264.85 | 15-NOV-08:61 | 25110.87 | 24-NOV-08:04 | 13753.46 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.266153E+11 | 0.800345E+10 | 354.28 | 0.183751E+11 | 0.824019E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-00:10 | 55673.60 | 03-DEC-09:01 | 40815.17 | 20-DEC-08:62 | 26221.04 | 03-DEC-09:05 | 13584.21 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.353912E+12 | 0.107494E+12 | 4249.55 | 0.244985E+12 | 0.108928E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.228245E+11 | 0.692677E+10 | 323.15 | 0.156806E+11 | 0.626276E+10 | 0.00 | 1.00 | 0.00 | 54322.63 | 34628.39 | 22474.31 | 13132.97 | 0.00 | |||||||
Maximum of Months | 0.361615E+11 | 0.111124E+11 | 370.07 | 0.250034E+11 | 0.116997E+11 | 0.00 | 1.00 | 0.00 | 56505.11 | 40815.17 | 30098.38 | 14036.41 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.118004E+11 | 0.337851E+10 | 355.37 | 0.856835E+10 | 0.323205E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 28335.13 | 02-JAN-08:62 | 21013.85 | 21-JAN-08:62 | 12171.57 | 02-JAN-08:03 | 6559.23 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 |
February | 0.122637E+11 | 0.344680E+10 | 323.18 | 0.810606E+10 | 0.415761E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 29094.74 | 18-FEB-08:62 | 17992.38 | 13-FEB-08:62 | 15364.65 | 18-FEB-08:03 | 6561.52 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.132137E+11 | 0.378939E+10 | 365.63 | 0.939829E+10 | 0.381538E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28741.78 | 13-MAR-07:02 | 18917.26 | 19-MAR-08:62 | 14080.15 | 13-MAR-07:03 | 6437.18 | 13-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.123517E+11 | 0.357416E+10 | 344.24 | 0.899625E+10 | 0.335543E+10 | 0.00 | 1.00 | 06-APR-07:02 | 0.00 | 01-APR-00:03 | 28247.26 | 24-APR-07:02 | 20113.92 | 30-APR-08:62 | 12499.23 | 24-APR-07:02 | 6501.88 | 09-APR-08:62 | 0.00 | 01-APR-00:03 |
May | 0.156511E+11 | 0.452418E+10 | 364.72 | 0.110181E+11 | 0.463305E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 28766.49 | 15-MAY-07:02 | 19890.25 | 02-MAY-07:02 | 14049.68 | 15-MAY-07:03 | 6663.60 | 14-MAY-08:61 | 0.00 | 01-MAY-00:10 |
June | 0.158668E+11 | 0.456129E+10 | 356.62 | 0.110358E+11 | 0.483098E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28334.10 | 18-JUN-08:61 | 18401.25 | 06-JUN-07:02 | 11676.57 | 14-JUN-07:03 | 6706.33 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.179810E+11 | 0.517526E+10 | 356.87 | 0.123290E+11 | 0.565193E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 29240.32 | 23-JUL-08:61 | 18508.88 | 04-JUL-08:61 | 14273.96 | 23-JUL-08:04 | 6749.74 | 23-JUL-08:13 | 0.00 | 01-JUL-00:03 |
August | 0.187140E+11 | 0.542559E+10 | 369.70 | 0.129444E+11 | 0.576963E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28954.72 | 20-AUG-08:61 | 18103.35 | 23-AUG-07:02 | 13414.24 | 20-AUG-08:04 | 6816.92 | 27-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.181031E+11 | 0.513870E+10 | 349.44 | 0.120542E+11 | 0.604892E+10 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 29401.44 | 25-SEP-07:01 | 18475.33 | 19-SEP-07:02 | 15769.67 | 25-SEP-07:01 | 6878.95 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.180956E+11 | 0.519485E+10 | 359.46 | 0.123656E+11 | 0.572996E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28810.41 | 10-OCT-07:02 | 18386.35 | 26-OCT-07:02 | 14180.66 | 23-OCT-07:02 | 6762.17 | 08-OCT-08:03 | 0.00 | 01-OCT-00:03 |
November | 0.152405E+11 | 0.433899E+10 | 349.43 | 0.104353E+11 | 0.480516E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28654.96 | 24-NOV-08:61 | 19356.57 | 15-NOV-08:61 | 13111.58 | 24-NOV-08:04 | 6739.87 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.137669E+11 | 0.390584E+10 | 354.79 | 0.951083E+10 | 0.425607E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-00:10 | 28932.69 | 03-DEC-09:01 | 21218.35 | 20-DEC-08:62 | 13654.77 | 03-DEC-09:05 | 6657.43 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.183048E+12 | 0.524536E+11 | 4249.44 | 0.126762E+12 | 0.562862E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.118004E+11 | 0.337851E+10 | 323.18 | 0.810606E+10 | 0.323205E+10 | 0.00 | 1.00 | 0.00 | 28247.26 | 17992.38 | 11676.57 | 6437.18 | 0.00 | |||||||
Maximum of Months | 0.187140E+11 | 0.542559E+10 | 369.70 | 0.129444E+11 | 0.604892E+10 | 0.00 | 1.00 | 0.00 | 29401.44 | 21218.35 | 15769.67 | 6878.95 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.116963E+11 | 0.334993E+10 | 355.24 | 0.848106E+10 | 0.321527E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 28214.16 | 02-JAN-08:62 | 20884.91 | 21-JAN-08:62 | 12149.53 | 02-JAN-08:03 | 6532.10 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 |
February | 0.121616E+11 | 0.341900E+10 | 323.11 | 0.802425E+10 | 0.413733E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 28973.83 | 18-FEB-08:62 | 17876.74 | 13-FEB-08:62 | 15340.40 | 18-FEB-08:03 | 6534.54 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.131035E+11 | 0.375889E+10 | 365.74 | 0.930687E+10 | 0.379662E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28619.15 | 13-MAR-07:02 | 18803.14 | 19-MAR-08:62 | 14053.18 | 13-MAR-07:03 | 6410.54 | 13-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.122522E+11 | 0.354649E+10 | 344.25 | 0.891236E+10 | 0.333984E+10 | 0.00 | 1.00 | 06-APR-07:02 | 0.00 | 01-APR-00:03 | 28127.24 | 24-APR-07:02 | 19992.15 | 30-APR-08:62 | 12481.89 | 24-APR-07:02 | 6474.81 | 09-APR-08:62 | 0.00 | 01-APR-00:03 |
May | 0.155472E+11 | 0.449495E+10 | 364.75 | 0.109308E+11 | 0.461650E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 28644.44 | 15-MAY-07:02 | 19761.92 | 02-MAY-07:02 | 14021.90 | 15-MAY-07:03 | 6636.10 | 14-MAY-08:61 | 0.00 | 01-MAY-00:10 |
June | 0.157656E+11 | 0.453303E+10 | 356.75 | 0.109509E+11 | 0.481468E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28213.45 | 18-JUN-08:61 | 18278.32 | 06-JUN-07:02 | 11661.68 | 14-JUN-07:03 | 6678.67 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.178793E+11 | 0.514635E+10 | 356.87 | 0.122438E+11 | 0.563548E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 29116.56 | 23-JUL-08:61 | 18397.48 | 04-JUL-08:61 | 14238.83 | 23-JUL-08:04 | 6721.99 | 23-JUL-08:13 | 0.00 | 01-JUL-00:03 |
August | 0.186115E+11 | 0.539605E+10 | 369.74 | 0.128580E+11 | 0.575355E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28833.40 | 20-AUG-08:61 | 17991.03 | 23-AUG-07:02 | 13377.92 | 20-AUG-08:04 | 6788.90 | 27-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.180013E+11 | 0.511006E+10 | 349.43 | 0.119700E+11 | 0.603124E+10 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 29277.32 | 25-SEP-07:01 | 18354.19 | 19-SEP-07:02 | 15732.27 | 25-SEP-07:01 | 6850.67 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.179950E+11 | 0.516625E+10 | 359.54 | 0.122811E+11 | 0.571389E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28688.32 | 10-OCT-07:02 | 18259.99 | 26-OCT-07:02 | 14152.73 | 23-OCT-07:02 | 6734.36 | 08-OCT-08:03 | 0.00 | 01-OCT-00:03 |
November | 0.151368E+11 | 0.431024E+10 | 349.38 | 0.103497E+11 | 0.478704E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28532.97 | 24-NOV-08:61 | 19235.56 | 15-NOV-08:61 | 12969.97 | 24-NOV-08:03 | 6712.08 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.136623E+11 | 0.387718E+10 | 354.75 | 0.942427E+10 | 0.423806E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-00:10 | 28810.23 | 03-DEC-09:01 | 21089.49 | 20-DEC-08:62 | 13618.68 | 03-DEC-09:05 | 6630.05 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.181813E+12 | 0.521084E+11 | 4249.55 | 0.125733E+12 | 0.560795E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.116963E+11 | 0.334993E+10 | 323.11 | 0.802425E+10 | 0.321527E+10 | 0.00 | 1.00 | 0.00 | 28127.24 | 17876.74 | 11661.68 | 6410.54 | 0.00 | |||||||
Maximum of Months | 0.186115E+11 | 0.539605E+10 | 369.74 | 0.128580E+11 | 0.603124E+10 | 0.00 | 1.00 | 0.00 | 29277.32 | 21089.49 | 15732.27 | 6850.67 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.115859E+11 | 0.332134E+10 | 355.31 | 0.839303E+10 | 0.319283E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 28225.11 | 02-JAN-08:62 | 19821.63 | 12-JAN-08:62 | 12211.81 | 02-JAN-08:03 | 6536.90 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 |
February | 0.120434E+11 | 0.338873E+10 | 323.26 | 0.793414E+10 | 0.410922E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 28988.74 | 18-FEB-08:62 | 17800.73 | 13-FEB-08:62 | 15417.55 | 18-FEB-08:03 | 6539.99 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.129862E+11 | 0.372835E+10 | 365.86 | 0.921492E+10 | 0.377133E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28633.36 | 13-MAR-07:02 | 18758.41 | 19-MAR-08:62 | 14111.87 | 13-MAR-07:03 | 6415.48 | 13-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.121720E+11 | 0.352572E+10 | 344.38 | 0.884865E+10 | 0.332336E+10 | 0.00 | 1.00 | 06-APR-07:02 | 0.00 | 01-APR-00:03 | 28138.67 | 24-APR-07:02 | 19934.54 | 30-APR-08:62 | 12549.16 | 24-APR-07:02 | 6479.26 | 09-APR-08:62 | 0.00 | 01-APR-00:03 |
May | 0.155071E+11 | 0.448504E+10 | 364.55 | 0.108995E+11 | 0.460760E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 28658.00 | 15-MAY-07:02 | 19704.00 | 02-MAY-07:02 | 14078.18 | 15-MAY-07:03 | 6641.29 | 14-MAY-08:61 | 0.00 | 01-MAY-00:10 |
June | 0.157340E+11 | 0.452567E+10 | 356.89 | 0.109267E+11 | 0.480735E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28227.76 | 18-JUN-08:61 | 18236.89 | 04-JUN-08:61 | 11713.88 | 14-JUN-07:03 | 6684.02 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.178689E+11 | 0.514454E+10 | 356.91 | 0.122368E+11 | 0.563204E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 29134.42 | 23-JUL-08:61 | 18363.03 | 04-JUL-08:61 | 14279.25 | 23-JUL-08:04 | 6727.55 | 23-JUL-08:13 | 0.00 | 01-JUL-00:03 |
August | 0.186169E+11 | 0.539811E+10 | 369.70 | 0.128633E+11 | 0.575358E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28850.78 | 20-AUG-08:61 | 17959.23 | 23-AUG-07:02 | 13415.15 | 20-AUG-08:04 | 6794.52 | 27-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.179830E+11 | 0.510600E+10 | 349.40 | 0.119568E+11 | 0.602619E+10 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 29295.89 | 25-SEP-07:01 | 18321.77 | 19-SEP-07:02 | 15774.14 | 25-SEP-07:01 | 6856.33 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.179772E+11 | 0.516214E+10 | 359.50 | 0.122680E+11 | 0.570913E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28705.13 | 10-OCT-07:02 | 18223.66 | 26-OCT-07:02 | 14205.10 | 23-OCT-07:02 | 6739.92 | 08-OCT-08:03 | 0.00 | 01-OCT-00:03 |
November | 0.150694E+11 | 0.429365E+10 | 349.51 | 0.102978E+11 | 0.477154E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28546.06 | 24-NOV-08:61 | 19178.63 | 15-NOV-08:61 | 13025.72 | 24-NOV-08:03 | 6717.40 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.135727E+11 | 0.385459E+10 | 354.80 | 0.935386E+10 | 0.421880E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-00:10 | 28825.95 | 03-DEC-09:01 | 21031.86 | 20-DEC-08:62 | 13664.60 | 03-DEC-09:05 | 6635.55 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.181117E+12 | 0.519339E+11 | 4250.07 | 0.125194E+12 | 0.559230E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.115859E+11 | 0.332134E+10 | 323.26 | 0.793414E+10 | 0.319283E+10 | 0.00 | 1.00 | 0.00 | 28138.67 | 17800.73 | 11713.88 | 6415.48 | 0.00 | |||||||
Maximum of Months | 0.186169E+11 | 0.539811E+10 | 369.70 | 0.128633E+11 | 0.602619E+10 | 0.00 | 1.00 | 0.00 | 29295.89 | 21031.86 | 15774.14 | 6856.33 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.125285E+11 | 0.359690E+10 | 358.71 | 0.920456E+10 | 0.332397E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 | 30847.78 | 03-JAN-08:62 | 20827.46 | 22-JAN-09:02 | 14550.39 | 31-JAN-08:62 | 7107.04 | 01-JAN-09:02 | 0.00 | 01-JAN-00:03 |
February | 0.127979E+11 | 0.361298E+10 | 324.11 | 0.854516E+10 | 0.425279E+10 | 0.00 | 1.00 | 17-FEB-08:62 | 0.00 | 01-FEB-00:05 | 31990.84 | 18-FEB-08:62 | 17514.31 | 26-FEB-09:02 | 18683.38 | 18-FEB-08:62 | 7108.21 | 18-FEB-08:03 | 0.00 | 01-FEB-00:05 |
March | 0.139247E+11 | 0.400605E+10 | 366.51 | 0.100120E+11 | 0.391269E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:03 | 31226.40 | 13-MAR-07:02 | 20430.76 | 19-MAR-08:62 | 15705.37 | 13-MAR-07:02 | 6999.75 | 15-MAR-07:02 | 0.00 | 01-MAR-00:03 |
April | 0.133841E+11 | 0.387670E+10 | 347.97 | 0.987316E+10 | 0.351098E+10 | 0.00 | 1.00 | 07-APR-07:02 | 0.00 | 01-APR-00:03 | 30595.33 | 24-APR-07:02 | 21523.71 | 30-APR-08:62 | 13680.09 | 24-APR-07:02 | 7060.17 | 09-APR-08:62 | 0.00 | 01-APR-00:03 |
May | 0.172213E+11 | 0.497553E+10 | 364.78 | 0.123059E+11 | 0.491549E+10 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 31259.72 | 10-MAY-07:02 | 20423.29 | 30-MAY-07:02 | 15522.74 | 10-MAY-07:03 | 7226.18 | 14-MAY-08:61 | 0.00 | 01-MAY-00:10 |
June | 0.174868E+11 | 0.502276E+10 | 357.23 | 0.123312E+11 | 0.515564E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 30923.68 | 14-JUN-07:02 | 19830.99 | 04-JUN-08:61 | 14141.57 | 14-JUN-07:03 | 7269.49 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.198678E+11 | 0.571292E+10 | 357.16 | 0.138300E+11 | 0.603783E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:03 | 31886.40 | 23-JUL-08:61 | 19623.83 | 04-JUL-08:61 | 16888.08 | 20-JUL-07:03 | 7315.67 | 23-JUL-08:13 | 0.00 | 01-JUL-00:03 |
August | 0.208048E+11 | 0.602057E+10 | 370.11 | 0.146146E+11 | 0.619020E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 31579.55 | 20-AUG-08:61 | 18750.16 | 07-AUG-07:01 | 14857.95 | 08-AUG-07:03 | 7389.06 | 27-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.197102E+11 | 0.559928E+10 | 350.02 | 0.133011E+11 | 0.640912E+10 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 31883.27 | 25-SEP-07:01 | 18961.28 | 27-SEP-07:02 | 17186.60 | 25-SEP-07:01 | 7456.26 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.198496E+11 | 0.569757E+10 | 359.49 | 0.137807E+11 | 0.606888E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 31283.88 | 10-OCT-07:02 | 19202.99 | 26-OCT-07:02 | 15646.27 | 10-OCT-07:03 | 7328.81 | 08-OCT-08:03 | 0.00 | 01-OCT-00:03 |
November | 0.163820E+11 | 0.467339E+10 | 350.14 | 0.113452E+11 | 0.503684E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 31226.88 | 01-NOV-07:02 | 20773.31 | 15-NOV-08:61 | 15148.45 | 01-NOV-07:03 | 7313.63 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.146717E+11 | 0.417408E+10 | 356.20 | 0.102540E+11 | 0.441771E+10 | 0.00 | 1.00 | 01-DEC-08:61 | 0.00 | 01-DEC-00:10 | 31461.78 | 03-DEC-09:01 | 22934.70 | 25-DEC-09:02 | 14997.00 | 03-DEC-09:05 | 7215.34 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.198630E+12 | 0.569687E+11 | 4262.43 | 0.139398E+12 | 0.592322E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.125285E+11 | 0.359690E+10 | 324.11 | 0.854516E+10 | 0.332397E+10 | 0.00 | 1.00 | 0.00 | 30595.33 | 17514.31 | 13680.09 | 6999.75 | 0.00 | |||||||
Maximum of Months | 0.208048E+11 | 0.602057E+10 | 370.11 | 0.146146E+11 | 0.640912E+10 | 0.00 | 1.00 | 0.00 | 31990.84 | 22934.70 | 18683.38 | 7456.26 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.78 | 40.87 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.35 | 39.75 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.60 | 38.85 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.69 | 32.49 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 24.13 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.04 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.22 | 14.86 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.96 | 16.75 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.87 | 15.42 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.49 | 23.17 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.98 | 27.58 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.74 | 31.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.55 | 27.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.04 | 14.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.74 | 40.87 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.78 | 40.87 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.35 | 39.75 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.60 | 38.85 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.69 | 32.49 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 24.13 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.04 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.22 | 14.86 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.96 | 16.75 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.87 | 15.42 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.49 | 23.17 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.98 | 27.58 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.74 | 31.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.55 | 27.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.04 | 14.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.74 | 40.87 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.78 | 40.87 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.35 | 39.75 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.60 | 38.85 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.69 | 32.49 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 24.13 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.04 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.22 | 14.86 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.96 | 16.75 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.87 | 15.42 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.49 | 23.17 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.98 | 27.58 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.74 | 31.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.55 | 27.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.04 | 14.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.74 | 40.87 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.78 | 40.87 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.35 | 39.75 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.60 | 38.85 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.69 | 32.49 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 24.13 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.04 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.22 | 14.86 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.96 | 16.75 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.87 | 15.42 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.49 | 23.17 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.98 | 27.58 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.74 | 31.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.55 | 27.03 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.04 | 14.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.74 | 40.87 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.93 | 41.34 | 24.59 | 185.01 | 48.76 | 0.00 | 0.00 | 744.00 |
February | 57.31 | 31.16 | 26.15 | 159.47 | 47.36 | 0.00 | 0.00 | 672.00 |
March | 43.09 | 16.38 | 26.70 | 121.42 | 46.29 | 0.00 | 0.00 | 744.00 |
April | 27.56 | 3.83 | 23.74 | 73.65 | 38.79 | 0.00 | 0.00 | 720.00 |
May | 22.30 | 0.12 | 22.18 | 68.15 | 28.85 | 0.00 | 0.00 | 744.00 |
June | 21.99 | 0.00 | 21.99 | 66.75 | 23.19 | 0.00 | 0.00 | 720.00 |
July | 21.37 | 0.10 | 21.27 | 74.03 | 17.85 | 0.00 | 0.00 | 744.00 |
August | 24.11 | 2.22 | 21.90 | 84.44 | 20.11 | 0.00 | 0.00 | 744.00 |
September | 37.59 | 10.89 | 26.70 | 123.81 | 18.52 | 0.00 | 0.00 | 720.00 |
October | 52.12 | 26.28 | 25.84 | 172.36 | 27.75 | 0.00 | 0.00 | 744.00 |
November | 63.44 | 36.50 | 26.93 | 191.11 | 32.99 | 0.00 | 0.00 | 720.00 |
December | 67.69 | 43.40 | 24.29 | 193.35 | 38.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.96 | 17.63 | 24.34 | 125.99 | 32.30 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.37 | 0.00 | 21.27 | 66.75 | 17.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.69 | 43.40 | 26.93 | 193.35 | 48.76 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.93 | 41.34 | 24.59 | 185.01 | 48.76 | 0.00 | 0.00 | 744.00 |
February | 57.31 | 31.16 | 26.15 | 159.47 | 47.36 | 0.00 | 0.00 | 672.00 |
March | 43.09 | 16.38 | 26.70 | 121.42 | 46.29 | 0.00 | 0.00 | 744.00 |
April | 27.56 | 3.83 | 23.74 | 73.65 | 38.79 | 0.00 | 0.00 | 720.00 |
May | 22.30 | 0.12 | 22.18 | 68.15 | 28.85 | 0.00 | 0.00 | 744.00 |
June | 21.99 | 0.00 | 21.99 | 66.75 | 23.19 | 0.00 | 0.00 | 720.00 |
July | 21.37 | 0.10 | 21.27 | 74.03 | 17.85 | 0.00 | 0.00 | 744.00 |
August | 24.11 | 2.22 | 21.90 | 84.44 | 20.11 | 0.00 | 0.00 | 744.00 |
September | 37.59 | 10.89 | 26.70 | 123.81 | 18.52 | 0.00 | 0.00 | 720.00 |
October | 52.12 | 26.28 | 25.84 | 172.36 | 27.75 | 0.00 | 0.00 | 744.00 |
November | 63.44 | 36.50 | 26.93 | 191.11 | 32.99 | 0.00 | 0.00 | 720.00 |
December | 67.69 | 43.40 | 24.29 | 193.35 | 38.15 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.96 | 17.63 | 24.34 | 125.99 | 32.30 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.37 | 0.00 | 21.27 | 66.75 | 17.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.69 | 43.40 | 26.93 | 193.35 | 48.76 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 153.95 | 41.51 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.64 | 40.29 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.24 | 39.41 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.62 | 32.90 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.44 | 24.35 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.40 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.77 | 14.74 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.56 | 16.57 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.34 | 15.14 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.46 | 23.20 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.48 | 27.73 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 160.96 | 32.28 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.46 | 27.22 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.40 | 14.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 160.96 | 41.51 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 153.95 | 41.51 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.64 | 40.29 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.24 | 39.41 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.62 | 32.90 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.44 | 24.35 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.40 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.77 | 14.74 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.56 | 16.57 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.34 | 15.14 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.46 | 23.20 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.48 | 27.73 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 160.96 | 32.28 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.46 | 27.22 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.40 | 14.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 160.96 | 41.51 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.93 | 41.34 | 24.59 | 184.09 | 49.49 | 0.00 | 0.00 | 744.00 |
February | 57.31 | 31.16 | 26.15 | 158.69 | 47.98 | 0.00 | 0.00 | 672.00 |
March | 43.09 | 16.38 | 26.70 | 121.04 | 46.93 | 0.00 | 0.00 | 744.00 |
April | 27.56 | 3.83 | 23.74 | 73.60 | 39.25 | 0.00 | 0.00 | 720.00 |
May | 22.30 | 0.12 | 22.18 | 68.45 | 29.10 | 0.00 | 0.00 | 744.00 |
June | 21.99 | 0.00 | 21.99 | 67.19 | 23.18 | 0.00 | 0.00 | 720.00 |
July | 21.37 | 0.10 | 21.27 | 74.70 | 17.70 | 0.00 | 0.00 | 744.00 |
August | 24.11 | 2.22 | 21.90 | 85.17 | 19.88 | 0.00 | 0.00 | 744.00 |
September | 37.59 | 10.89 | 26.70 | 124.41 | 18.17 | 0.00 | 0.00 | 720.00 |
October | 52.12 | 26.28 | 25.84 | 172.37 | 27.78 | 0.00 | 0.00 | 744.00 |
November | 63.44 | 36.50 | 26.93 | 190.59 | 33.15 | 0.00 | 0.00 | 720.00 |
December | 67.69 | 43.40 | 24.29 | 192.50 | 38.56 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.96 | 17.63 | 24.34 | 125.93 | 32.52 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.37 | 0.00 | 21.27 | 67.19 | 17.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.69 | 43.40 | 26.93 | 192.50 | 49.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.19 | 44.14 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.61 | 43.12 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 100.97 | 42.19 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.48 | 35.75 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.24 | 27.76 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.26 | 22.87 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.33 | 18.75 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.26 | 20.37 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.44 | 19.07 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.14 | 27.18 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.68 | 31.04 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.24 | 35.40 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.29 | 30.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.26 | 18.75 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.24 | 44.14 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.19 | 44.14 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.61 | 43.12 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 100.97 | 42.19 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.48 | 35.75 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.24 | 27.76 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.26 | 22.87 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.33 | 18.75 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.26 | 20.37 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.44 | 19.07 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.14 | 27.18 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.68 | 31.04 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.24 | 35.40 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.29 | 30.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.26 | 18.75 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.24 | 44.14 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 183.35 | 52.23 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 157.79 | 50.95 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 120.06 | 49.87 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 73.03 | 42.31 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 67.84 | 32.88 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.66 | 27.12 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 73.78 | 22.24 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 84.35 | 24.17 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 122.69 | 22.63 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 171.06 | 32.23 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 189.77 | 36.79 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 191.76 | 41.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 125.04 | 36.20 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.66 | 22.24 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 191.76 | 52.23 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.21 | 44.09 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.62 | 43.12 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 100.96 | 42.24 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.48 | 35.80 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 27.96 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.22 | 23.10 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.26 | 19.09 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.20 | 20.68 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.36 | 19.46 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.08 | 27.49 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.66 | 31.17 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.24 | 35.44 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.26 | 30.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.22 | 19.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.24 | 44.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.21 | 44.09 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.62 | 43.12 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 100.96 | 42.24 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.48 | 35.80 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.21 | 27.96 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.22 | 23.10 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.26 | 19.09 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.20 | 20.68 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.36 | 19.46 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.08 | 27.49 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.66 | 31.17 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.24 | 35.44 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.26 | 30.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.22 | 19.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.24 | 44.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 183.37 | 52.16 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 157.80 | 50.96 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 120.05 | 49.93 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 73.03 | 42.37 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 67.80 | 33.11 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.61 | 27.38 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 73.69 | 22.64 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 84.28 | 24.54 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 122.59 | 23.10 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 170.98 | 32.60 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 189.74 | 36.94 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 191.75 | 41.97 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 125.01 | 36.40 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.61 | 22.64 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 191.75 | 52.16 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.39 | 43.50 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.80 | 42.50 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.14 | 41.62 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.65 | 35.21 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.38 | 27.43 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.38 | 22.58 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.40 | 18.62 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.35 | 20.17 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.49 | 18.98 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.22 | 26.98 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.83 | 30.64 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.42 | 34.87 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.43 | 30.20 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.38 | 18.62 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.42 | 43.50 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.39 | 43.50 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 132.80 | 42.50 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.14 | 41.62 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.65 | 35.21 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.38 | 27.43 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.38 | 22.58 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.40 | 18.62 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.35 | 20.17 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.49 | 18.98 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.22 | 26.98 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.83 | 30.64 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.42 | 34.87 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.43 | 30.20 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.38 | 18.62 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.42 | 43.50 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 183.59 | 51.47 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 158.02 | 50.23 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 120.27 | 49.20 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 73.24 | 41.68 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 68.00 | 32.48 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.80 | 26.78 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 73.86 | 22.09 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 84.45 | 23.94 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 122.75 | 22.54 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 171.15 | 32.00 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 189.95 | 36.32 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 191.97 | 41.30 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 125.20 | 35.76 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.80 | 22.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 191.97 | 51.47 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.38 | 41.25 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 134.04 | 40.13 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.26 | 39.29 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.34 | 33.07 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.63 | 25.31 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.50 | 20.45 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.27 | 16.70 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.36 | 18.09 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.88 | 17.17 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.72 | 24.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.52 | 28.54 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.32 | 32.67 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.99 | 28.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.50 | 16.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.32 | 41.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.38 | 41.25 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 134.04 | 40.13 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.26 | 39.29 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.34 | 33.07 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.63 | 25.31 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.50 | 20.45 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.27 | 16.70 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.36 | 18.09 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.88 | 17.17 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.72 | 24.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.52 | 28.54 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.32 | 32.67 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.99 | 28.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.50 | 16.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.32 | 41.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.38 | 41.25 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 134.04 | 40.13 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.26 | 39.29 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.34 | 33.07 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.63 | 25.31 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.50 | 20.45 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.27 | 16.70 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.36 | 18.09 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.88 | 17.17 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.72 | 24.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.52 | 28.54 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.32 | 32.67 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.99 | 28.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.50 | 16.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.32 | 41.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.38 | 41.25 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 134.04 | 40.13 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.26 | 39.29 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.34 | 33.07 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 57.63 | 25.31 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 56.50 | 20.45 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.27 | 16.70 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.36 | 18.09 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 103.88 | 17.17 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.72 | 24.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.52 | 28.54 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.32 | 32.67 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.99 | 28.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 56.50 | 16.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.32 | 41.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.74 | 48.84 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 159.46 | 47.45 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.57 | 46.48 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 74.06 | 39.17 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 68.32 | 30.00 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.96 | 24.28 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 73.73 | 19.84 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 84.49 | 21.50 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 123.21 | 20.41 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 171.74 | 29.64 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 190.74 | 33.85 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 193.01 | 38.72 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 125.86 | 33.27 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.96 | 19.84 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 193.01 | 48.84 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.74 | 48.84 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 159.46 | 47.45 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.57 | 46.48 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 74.06 | 39.17 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 68.32 | 30.00 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.96 | 24.28 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 73.73 | 19.84 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 84.49 | 21.50 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 123.21 | 20.41 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 171.74 | 29.64 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 190.74 | 33.85 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 193.01 | 38.72 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 125.86 | 33.27 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.96 | 19.84 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 193.01 | 48.84 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.07 | 40.65 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.71 | 39.45 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.20 | 38.61 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.57 | 32.40 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.10 | 24.59 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.01 | 19.66 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.87 | 15.90 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.94 | 17.25 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.24 | 16.30 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.83 | 24.16 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.33 | 27.77 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.97 | 31.95 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.12 | 27.33 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.01 | 15.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.97 | 40.65 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.07 | 40.65 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.71 | 39.45 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.20 | 38.61 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.57 | 32.40 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.10 | 24.59 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.01 | 19.66 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.87 | 15.90 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.94 | 17.25 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.24 | 16.30 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.83 | 24.16 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.33 | 27.77 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.97 | 31.95 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.12 | 27.33 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.01 | 15.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.97 | 40.65 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.44 | 48.12 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 159.14 | 46.64 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.56 | 45.66 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 74.36 | 38.36 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 68.89 | 29.15 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 67.60 | 23.35 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 74.47 | 18.89 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 85.20 | 20.50 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 123.67 | 19.38 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 171.92 | 28.67 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 190.59 | 32.94 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 192.67 | 37.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 126.07 | 32.39 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 67.60 | 18.89 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 192.67 | 48.12 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.18 | 40.42 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.83 | 39.21 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.31 | 38.38 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.67 | 32.18 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.21 | 24.40 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.13 | 19.48 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.99 | 15.72 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 72.05 | 17.07 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.35 | 16.11 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.94 | 23.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.44 | 27.57 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.09 | 31.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.23 | 27.12 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.13 | 15.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.09 | 40.42 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.18 | 40.42 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.83 | 39.21 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.31 | 38.38 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.67 | 32.18 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.21 | 24.40 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.13 | 19.48 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.99 | 15.72 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 72.05 | 17.07 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.35 | 16.11 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.94 | 23.97 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.44 | 27.57 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.09 | 31.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.23 | 27.12 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.13 | 15.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.09 | 40.42 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.58 | 47.85 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 159.28 | 46.36 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.69 | 45.38 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 74.49 | 38.10 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 69.03 | 28.92 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 67.74 | 23.13 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 74.60 | 18.67 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 85.33 | 20.29 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 123.80 | 19.15 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 172.05 | 28.45 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 190.73 | 32.70 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 192.81 | 37.61 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 126.21 | 32.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 67.74 | 18.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 192.81 | 47.85 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.30 | 40.09 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.94 | 38.84 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.38 | 38.03 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.71 | 31.90 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.21 | 24.24 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.12 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.95 | 15.65 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.99 | 17.03 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.30 | 16.06 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.91 | 23.89 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.50 | 27.38 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.17 | 31.48 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.26 | 26.94 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.12 | 15.65 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.17 | 40.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 155.30 | 40.09 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.94 | 38.84 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 102.38 | 38.03 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 62.71 | 31.90 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 58.21 | 24.24 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 57.12 | 19.35 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 62.95 | 15.65 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 71.99 | 17.03 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 104.30 | 16.06 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 144.91 | 23.89 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 160.50 | 27.38 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 162.17 | 31.48 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 106.26 | 26.94 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 57.12 | 15.65 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 162.17 | 40.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.72 | 47.46 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 159.41 | 45.92 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.78 | 44.98 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 74.54 | 37.78 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 69.03 | 28.74 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 67.73 | 22.99 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 74.56 | 18.60 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 85.26 | 20.25 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 123.75 | 19.09 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 172.01 | 28.37 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 190.80 | 32.48 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 192.91 | 37.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 126.24 | 31.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 67.73 | 18.60 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 192.91 | 47.46 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.80 | 38.96 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.55 | 37.57 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.75 | 36.82 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.77 | 30.99 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 56.89 | 23.97 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 55.78 | 19.26 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 61.44 | 15.90 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.33 | 17.45 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 102.97 | 16.48 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 143.50 | 24.18 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.67 | 27.03 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.53 | 30.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.21 | 26.56 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 55.78 | 15.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.53 | 38.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 54.76 | 34.33 | 20.43 | 154.80 | 38.96 | 0.00 | 0.00 | 744.00 |
February | 47.60 | 25.88 | 21.72 | 133.55 | 37.57 | 0.00 | 0.00 | 672.00 |
March | 35.79 | 13.61 | 22.18 | 101.75 | 36.82 | 0.00 | 0.00 | 744.00 |
April | 22.89 | 3.18 | 19.72 | 61.77 | 30.99 | 0.00 | 0.00 | 720.00 |
May | 18.52 | 0.10 | 18.42 | 56.89 | 23.97 | 0.00 | 0.00 | 744.00 |
June | 18.27 | 0.00 | 18.27 | 55.78 | 19.26 | 0.00 | 0.00 | 720.00 |
July | 17.75 | 0.09 | 17.66 | 61.44 | 15.90 | 0.00 | 0.00 | 744.00 |
August | 20.03 | 1.84 | 18.19 | 70.33 | 17.45 | 0.00 | 0.00 | 744.00 |
September | 31.22 | 9.05 | 22.18 | 102.97 | 16.48 | 0.00 | 0.00 | 720.00 |
October | 43.29 | 21.82 | 21.47 | 143.50 | 24.18 | 0.00 | 0.00 | 744.00 |
November | 52.69 | 30.32 | 22.37 | 159.67 | 27.03 | 0.00 | 0.00 | 720.00 |
December | 56.22 | 36.05 | 20.17 | 161.53 | 30.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 34.86 | 14.64 | 20.21 | 105.21 | 26.56 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 17.75 | 0.00 | 17.66 | 55.78 | 15.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 56.22 | 36.05 | 22.37 | 161.53 | 38.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 65.57 | 41.11 | 24.46 | 184.11 | 46.14 | 0.00 | 0.00 | 744.00 |
February | 57.00 | 30.99 | 26.00 | 158.94 | 44.44 | 0.00 | 0.00 | 672.00 |
March | 42.85 | 16.29 | 26.56 | 121.02 | 43.56 | 0.00 | 0.00 | 744.00 |
April | 27.41 | 3.80 | 23.61 | 73.41 | 36.72 | 0.00 | 0.00 | 720.00 |
May | 22.18 | 0.12 | 22.06 | 67.44 | 28.43 | 0.00 | 0.00 | 744.00 |
June | 21.87 | 0.00 | 21.87 | 66.11 | 22.89 | 0.00 | 0.00 | 720.00 |
July | 21.25 | 0.10 | 21.15 | 72.73 | 18.90 | 0.00 | 0.00 | 744.00 |
August | 23.98 | 2.21 | 21.78 | 83.25 | 20.75 | 0.00 | 0.00 | 744.00 |
September | 37.39 | 10.84 | 26.55 | 122.14 | 19.59 | 0.00 | 0.00 | 720.00 |
October | 51.84 | 26.13 | 25.70 | 170.32 | 28.71 | 0.00 | 0.00 | 744.00 |
November | 63.09 | 36.31 | 26.79 | 189.79 | 32.08 | 0.00 | 0.00 | 720.00 |
December | 67.32 | 43.16 | 24.16 | 192.13 | 36.53 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.74 | 17.53 | 24.20 | 124.97 | 31.50 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.25 | 0.00 | 21.15 | 66.11 | 18.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 67.32 | 43.16 | 26.79 | 192.13 | 46.14 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414554E+09 | 0.109472E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.322599E+09 | 96165699.16 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272129E+09 | 0.104051E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159893E+09 | 84215349.10 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153219E+09 | 64627316.14 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145264E+09 | 50145611.98 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166661E+09 | 39809810.83 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190063E+09 | 44862194.11 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269232E+09 | 39961463.25 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387007E+09 | 62049686.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414657E+09 | 71478114.91 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433215E+09 | 85511344.03 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332849E+10 | 0.852350E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145264E+09 | 39809810.83 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433215E+09 | 0.109472E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414554E+09 | 0.109472E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.322599E+09 | 96165699.16 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272129E+09 | 0.104051E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159893E+09 | 84215349.10 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153219E+09 | 64627316.14 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145264E+09 | 50145611.98 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166661E+09 | 39809810.83 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190063E+09 | 44862194.11 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269232E+09 | 39961463.25 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387007E+09 | 62049686.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414657E+09 | 71478114.91 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433215E+09 | 85511344.03 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332849E+10 | 0.852350E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145264E+09 | 39809810.83 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433215E+09 | 0.109472E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414554E+09 | 0.109472E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.322599E+09 | 96165699.16 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272129E+09 | 0.104051E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159893E+09 | 84215349.10 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153219E+09 | 64627316.14 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145264E+09 | 50145611.98 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166661E+09 | 39809810.83 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190063E+09 | 44862194.11 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269232E+09 | 39961463.25 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387007E+09 | 62049686.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414657E+09 | 71478114.91 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433215E+09 | 85511344.03 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332849E+10 | 0.852350E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145264E+09 | 39809810.83 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433215E+09 | 0.109472E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414554E+09 | 0.109472E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.322599E+09 | 96165699.16 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272129E+09 | 0.104051E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159893E+09 | 84215349.10 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153219E+09 | 64627316.14 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145264E+09 | 50145611.98 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166661E+09 | 39809810.83 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190063E+09 | 44862194.11 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269232E+09 | 39961463.25 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387007E+09 | 62049686.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414657E+09 | 71478114.91 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433215E+09 | 85511344.03 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332849E+10 | 0.852350E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145264E+09 | 39809810.83 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433215E+09 | 0.109472E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.176587E+09 | 0.110715E+09 | 65871525.64 | 0.495529E+09 | 0.130593E+09 |
February | 0.138640E+09 | 75389388.20 | 63250996.10 | 0.385801E+09 | 0.114584E+09 |
March | 0.115403E+09 | 43878764.60 | 71524592.42 | 0.325215E+09 | 0.123995E+09 |
April | 71441767.70 | 9915130.70 | 61526637.00 | 0.190908E+09 | 0.100534E+09 |
May | 59720006.37 | 323046.52 | 59396959.85 | 0.182521E+09 | 77270864.67 |
June | 57005299.91 | 0.00 | 57005299.91 | 0.173012E+09 | 60102860.11 |
July | 57239128.62 | 278175.78 | 56960952.84 | 0.198273E+09 | 47820457.88 |
August | 64588660.14 | 5944383.80 | 58644276.34 | 0.226153E+09 | 53855058.80 |
September | 97441651.84 | 28239168.89 | 69202482.95 | 0.320905E+09 | 47991975.57 |
October | 0.139600E+09 | 70377590.62 | 69222574.83 | 0.461657E+09 | 74321123.03 |
November | 0.164432E+09 | 94619928.65 | 69812062.45 | 0.495364E+09 | 85511276.93 |
December | 0.181301E+09 | 0.116243E+09 | 65057309.23 | 0.517879E+09 | 0.102186E+09 |
Annual Sum or Average | 0.132340E+10 | 0.555924E+09 | 0.767476E+09 | 0.397322E+10 | 0.101877E+10 |
Minimum of Months | 57005299.91 | 0.00 | 56960952.84 | 0.173012E+09 | 47820457.88 |
Maximum of Months | 0.181301E+09 | 0.116243E+09 | 71524592.42 | 0.517879E+09 | 0.130593E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.176587E+09 | 0.110715E+09 | 65871525.64 | 0.495529E+09 | 0.130593E+09 |
February | 0.138640E+09 | 75389388.20 | 63250996.10 | 0.385801E+09 | 0.114584E+09 |
March | 0.115403E+09 | 43878764.60 | 71524592.42 | 0.325215E+09 | 0.123995E+09 |
April | 71441767.70 | 9915130.70 | 61526637.00 | 0.190908E+09 | 0.100534E+09 |
May | 59720006.37 | 323046.52 | 59396959.85 | 0.182521E+09 | 77270864.67 |
June | 57005299.91 | 0.00 | 57005299.91 | 0.173012E+09 | 60102860.11 |
July | 57239128.62 | 278175.78 | 56960952.84 | 0.198273E+09 | 47820457.88 |
August | 64588660.14 | 5944383.80 | 58644276.34 | 0.226153E+09 | 53855058.80 |
September | 97441651.84 | 28239168.89 | 69202482.95 | 0.320905E+09 | 47991975.57 |
October | 0.139600E+09 | 70377590.62 | 69222574.83 | 0.461657E+09 | 74321123.03 |
November | 0.164432E+09 | 94619928.65 | 69812062.45 | 0.495364E+09 | 85511276.93 |
December | 0.181301E+09 | 0.116243E+09 | 65057309.23 | 0.517879E+09 | 0.102186E+09 |
Annual Sum or Average | 0.132340E+10 | 0.555924E+09 | 0.767476E+09 | 0.397322E+10 | 0.101877E+10 |
Minimum of Months | 57005299.91 | 0.00 | 56960952.84 | 0.173012E+09 | 47820457.88 |
Maximum of Months | 0.181301E+09 | 0.116243E+09 | 71524592.42 | 0.517879E+09 | 0.130593E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.412341E+09 | 0.111171E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320872E+09 | 97467693.65 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.271156E+09 | 0.105544E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159722E+09 | 85274849.70 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153852E+09 | 65215719.92 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146180E+09 | 50160905.29 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168135E+09 | 39482014.73 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191666E+09 | 44368204.80 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270453E+09 | 39232708.49 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386925E+09 | 62150337.84 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413371E+09 | 71863876.48 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431120E+09 | 86457124.36 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332579E+10 | 0.858388E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146180E+09 | 39232708.49 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431120E+09 | 0.111171E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.412341E+09 | 0.111171E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320872E+09 | 97467693.65 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.271156E+09 | 0.105544E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159722E+09 | 85274849.70 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153852E+09 | 65215719.92 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146180E+09 | 50160905.29 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168135E+09 | 39482014.73 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191666E+09 | 44368204.80 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270453E+09 | 39232708.49 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386925E+09 | 62150337.84 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413371E+09 | 71863876.48 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431120E+09 | 86457124.36 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332579E+10 | 0.858388E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146180E+09 | 39232708.49 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431120E+09 | 0.111171E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.176587E+09 | 0.110715E+09 | 65871525.64 | 0.493064E+09 | 0.132557E+09 |
February | 0.138640E+09 | 75389388.20 | 63250996.10 | 0.383907E+09 | 0.116080E+09 |
March | 0.115403E+09 | 43878764.60 | 71524592.42 | 0.324186E+09 | 0.125705E+09 |
April | 71441767.70 | 9915130.70 | 61526637.00 | 0.190780E+09 | 0.101741E+09 |
May | 59720006.37 | 323046.52 | 59396959.85 | 0.183331E+09 | 77929657.76 |
June | 57005299.91 | 0.00 | 57005299.91 | 0.174165E+09 | 60089061.03 |
July | 57239128.62 | 278175.78 | 56960952.84 | 0.200078E+09 | 47399827.31 |
August | 64588660.14 | 5944383.80 | 58644276.34 | 0.228111E+09 | 53236049.05 |
September | 97441651.84 | 28239168.89 | 69202482.95 | 0.322463E+09 | 47094947.47 |
October | 0.139600E+09 | 70377590.62 | 69222574.83 | 0.461687E+09 | 74411770.78 |
November | 0.164432E+09 | 94619928.65 | 69812062.45 | 0.494008E+09 | 85934442.64 |
December | 0.181301E+09 | 0.116243E+09 | 65057309.23 | 0.515582E+09 | 0.103269E+09 |
Annual Sum or Average | 0.132340E+10 | 0.555924E+09 | 0.767476E+09 | 0.397136E+10 | 0.102545E+10 |
Minimum of Months | 57005299.91 | 0.00 | 56960952.84 | 0.174165E+09 | 47094947.47 |
Maximum of Months | 0.181301E+09 | 0.116243E+09 | 71524592.42 | 0.515582E+09 | 0.132557E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.412971E+09 | 0.118228E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320807E+09 | 0.104313E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270426E+09 | 0.112995E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159346E+09 | 92674286.54 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153324E+09 | 74358748.38 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145816E+09 | 59291807.04 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166948E+09 | 50218676.60 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190863E+09 | 54554476.37 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.268121E+09 | 49417860.84 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386071E+09 | 72795667.31 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413889E+09 | 80467869.72 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431875E+09 | 94806630.40 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332046E+10 | 0.964122E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145816E+09 | 49417860.84 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431875E+09 | 0.118228E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.412971E+09 | 0.118228E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320807E+09 | 0.104313E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270426E+09 | 0.112995E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159346E+09 | 92674286.54 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153324E+09 | 74358748.38 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145816E+09 | 59291807.04 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166948E+09 | 50218676.60 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190863E+09 | 54554476.37 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.268121E+09 | 49417860.84 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386071E+09 | 72795667.31 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413889E+09 | 80467869.72 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431875E+09 | 94806630.40 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332046E+10 | 0.964122E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145816E+09 | 49417860.84 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431875E+09 | 0.118228E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.491074E+09 | 0.139886E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.381724E+09 | 0.123265E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.321563E+09 | 0.133560E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.189295E+09 | 0.109679E+09 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.181704E+09 | 88055955.61 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.172770E+09 | 70305109.82 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.197601E+09 | 59575890.55 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.225920E+09 | 64741977.25 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.318012E+09 | 58667938.64 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.458154E+09 | 86336141.95 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.491872E+09 | 95362119.14 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.513598E+09 | 0.112275E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.394329E+10 | 0.114171E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.172770E+09 | 58667938.64 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.513598E+09 | 0.139886E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.413027E+09 | 0.118080E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320826E+09 | 0.104323E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270412E+09 | 0.113142E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159346E+09 | 92795772.20 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153238E+09 | 74884350.91 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145712E+09 | 59864309.22 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166760E+09 | 51118873.56 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190710E+09 | 55381226.59 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.267904E+09 | 50446207.49 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.385906E+09 | 73635706.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413836E+09 | 80799242.62 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431873E+09 | 94923881.41 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.331955E+10 | 0.969395E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145712E+09 | 50446207.49 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431873E+09 | 0.118080E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.413027E+09 | 0.118080E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.320826E+09 | 0.104323E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270412E+09 | 0.113142E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159346E+09 | 92795772.20 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153238E+09 | 74884350.91 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.145712E+09 | 59864309.22 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166760E+09 | 51118873.56 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.190710E+09 | 55381226.59 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.267904E+09 | 50446207.49 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.385906E+09 | 73635706.75 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413836E+09 | 80799242.62 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.431873E+09 | 94923881.41 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.331955E+10 | 0.969395E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.145712E+09 | 50446207.49 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.431873E+09 | 0.118080E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.491142E+09 | 0.139712E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.381747E+09 | 0.123276E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.321545E+09 | 0.133735E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.189296E+09 | 0.109821E+09 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.181600E+09 | 88675817.79 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.172645E+09 | 70980730.57 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.197374E+09 | 60638452.78 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.225736E+09 | 65718608.88 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.317750E+09 | 59881904.19 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.457955E+09 | 87328893.61 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.491809E+09 | 95752585.59 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.513596E+09 | 0.112413E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.394220E+10 | 0.114793E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.172645E+09 | 59881904.19 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.513596E+09 | 0.139712E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.413519E+09 | 0.116505E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.321276E+09 | 0.102819E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270897E+09 | 0.111477E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159800E+09 | 91267018.08 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153677E+09 | 73456196.55 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146133E+09 | 58537071.11 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.167138E+09 | 49865155.61 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191098E+09 | 54020908.99 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.268247E+09 | 49193523.78 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386290E+09 | 72266563.02 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414284E+09 | 79429644.56 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.432353E+09 | 93403109.10 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332471E+10 | 0.952241E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146133E+09 | 49193523.78 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.432353E+09 | 0.116505E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.413519E+09 | 0.116505E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.321276E+09 | 0.102819E+09 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.270897E+09 | 0.111477E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.159800E+09 | 91267018.08 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.153677E+09 | 73456196.55 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146133E+09 | 58537071.11 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.167138E+09 | 49865155.61 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191098E+09 | 54020908.99 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.268247E+09 | 49193523.78 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.386290E+09 | 72266563.02 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.414284E+09 | 79429644.56 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.432353E+09 | 93403109.10 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.332471E+10 | 0.952241E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146133E+09 | 49193523.78 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.432353E+09 | 0.116505E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.491735E+09 | 0.137864E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.382288E+09 | 0.121514E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.322130E+09 | 0.131782E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.189843E+09 | 0.108029E+09 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.182128E+09 | 87003698.81 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.173152E+09 | 69423879.49 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.197830E+09 | 59169643.11 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.226202E+09 | 64121251.68 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.318164E+09 | 58413218.11 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.458418E+09 | 85720276.30 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.492349E+09 | 94146666.87 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.514175E+09 | 0.110629E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.394842E+10 | 0.112782E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.173152E+09 | 58413218.11 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.514175E+09 | 0.137864E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.416165E+09 | 0.110484E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324271E+09 | 97072907.29 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273884E+09 | 0.105240E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.161596E+09 | 85717728.34 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.154368E+09 | 67788341.98 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146437E+09 | 52997034.34 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166789E+09 | 44730611.03 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191136E+09 | 48460750.42 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269264E+09 | 44509936.19 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387626E+09 | 66880153.27 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416059E+09 | 73966159.50 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434766E+09 | 87490102.42 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334236E+10 | 0.885338E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146437E+09 | 44509936.19 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434766E+09 | 0.110484E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.416165E+09 | 0.110484E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324271E+09 | 97072907.29 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273884E+09 | 0.105240E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.161596E+09 | 85717728.34 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.154368E+09 | 67788341.98 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146437E+09 | 52997034.34 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166789E+09 | 44730611.03 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191136E+09 | 48460750.42 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269264E+09 | 44509936.19 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387626E+09 | 66880153.27 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416059E+09 | 73966159.50 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434766E+09 | 87490102.42 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334236E+10 | 0.885338E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146437E+09 | 44509936.19 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434766E+09 | 0.110484E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.416165E+09 | 0.110484E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324271E+09 | 97072907.29 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273884E+09 | 0.105240E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.161596E+09 | 85717728.34 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.154368E+09 | 67788341.98 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146437E+09 | 52997034.34 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166789E+09 | 44730611.03 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191136E+09 | 48460750.42 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269264E+09 | 44509936.19 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387626E+09 | 66880153.27 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416059E+09 | 73966159.50 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434766E+09 | 87490102.42 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334236E+10 | 0.885338E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146437E+09 | 44509936.19 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434766E+09 | 0.110484E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.416165E+09 | 0.110484E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324271E+09 | 97072907.29 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273884E+09 | 0.105240E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.161596E+09 | 85717728.34 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.154368E+09 | 67788341.98 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.146437E+09 | 52997034.34 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.166789E+09 | 44730611.03 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.191136E+09 | 48460750.42 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.269264E+09 | 44509936.19 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387626E+09 | 66880153.27 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416059E+09 | 73966159.50 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434766E+09 | 87490102.42 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334236E+10 | 0.885338E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.146437E+09 | 44509936.19 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434766E+09 | 0.110484E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.494805E+09 | 0.130820E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.385757E+09 | 0.114794E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.325615E+09 | 0.124479E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.191969E+09 | 0.101522E+09 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.182990E+09 | 80362312.19 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.173565E+09 | 62930178.94 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.197486E+09 | 53142315.23 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.226308E+09 | 57585584.72 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.319361E+09 | 52890109.97 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.459984E+09 | 79383661.93 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.494407E+09 | 87743219.96 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.516966E+09 | 0.103706E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.396921E+10 | 0.104936E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.173565E+09 | 52890109.97 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.516966E+09 | 0.130820E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.494805E+09 | 0.130820E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.385757E+09 | 0.114794E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.325615E+09 | 0.124479E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.191969E+09 | 0.101522E+09 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.182990E+09 | 80362312.19 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.173565E+09 | 62930178.94 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.197486E+09 | 53142315.23 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.226308E+09 | 57585584.72 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.319361E+09 | 52890109.97 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.459984E+09 | 79383661.93 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.494407E+09 | 87743219.96 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.516966E+09 | 0.103706E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.396921E+10 | 0.104936E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.173565E+09 | 52890109.97 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.516966E+09 | 0.130820E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415328E+09 | 0.108870E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323472E+09 | 95440906.28 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273729E+09 | 0.103424E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162173E+09 | 83972582.46 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155605E+09 | 65858555.62 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.147769E+09 | 50966121.84 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168396E+09 | 42577976.25 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192695E+09 | 46202372.80 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270188E+09 | 42255523.54 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387922E+09 | 64703983.85 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.415566E+09 | 71986765.90 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433815E+09 | 85564578.04 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334666E+10 | 0.861824E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.147769E+09 | 42255523.54 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433815E+09 | 0.108870E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415328E+09 | 0.108870E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323472E+09 | 95440906.28 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.273729E+09 | 0.103424E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162173E+09 | 83972582.46 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155605E+09 | 65858555.62 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.147769E+09 | 50966121.84 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168396E+09 | 42577976.25 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192695E+09 | 46202372.80 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270188E+09 | 42255523.54 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.387922E+09 | 64703983.85 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.415566E+09 | 71986765.90 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.433815E+09 | 85564578.04 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.334666E+10 | 0.861824E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.147769E+09 | 42255523.54 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.433815E+09 | 0.108870E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.494008E+09 | 0.128877E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.384989E+09 | 0.112837E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.325583E+09 | 0.122303E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.192748E+09 | 99436758.31 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.184526E+09 | 78065799.32 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.175215E+09 | 60522827.49 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.199449E+09 | 50590649.89 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.228212E+09 | 54911179.00 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.320564E+09 | 50220935.64 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.460472E+09 | 76796897.10 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.494001E+09 | 85385759.69 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.516048E+09 | 0.101407E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.397582E+10 | 0.102136E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.175215E+09 | 50220935.64 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.516048E+09 | 0.128877E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415641E+09 | 0.108273E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323762E+09 | 94853869.97 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.274023E+09 | 0.102786E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162449E+09 | 83404010.57 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155911E+09 | 65341063.47 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.148077E+09 | 50484931.08 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168703E+09 | 42094566.43 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192978E+09 | 45725222.31 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270462E+09 | 41761318.76 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.388204E+09 | 64198135.84 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.415873E+09 | 71460790.98 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434132E+09 | 84988932.95 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.335022E+10 | 0.855371E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.148077E+09 | 41761318.76 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434132E+09 | 0.108273E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415641E+09 | 0.108273E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323762E+09 | 94853869.97 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.274023E+09 | 0.102786E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162449E+09 | 83404010.57 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155911E+09 | 65341063.47 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.148077E+09 | 50484931.08 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168703E+09 | 42094566.43 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192978E+09 | 45725222.31 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270462E+09 | 41761318.76 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.388204E+09 | 64198135.84 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.415873E+09 | 71460790.98 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434132E+09 | 84988932.95 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.335022E+10 | 0.855371E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.148077E+09 | 41761318.76 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434132E+09 | 0.108273E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.494382E+09 | 0.128172E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.385338E+09 | 0.112145E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.325938E+09 | 0.121550E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.193080E+09 | 98765698.42 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.184894E+09 | 77454752.78 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.175585E+09 | 59954522.09 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.199819E+09 | 50018448.24 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.228552E+09 | 54346705.76 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.320895E+09 | 49636572.75 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.460812E+09 | 76198426.98 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.494371E+09 | 84764140.09 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.516428E+09 | 0.100727E+09 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.398009E+10 | 0.101373E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.175585E+09 | 49636572.75 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.516428E+09 | 0.128172E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415943E+09 | 0.107380E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324024E+09 | 93957734.68 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.274210E+09 | 0.101866E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162557E+09 | 82675464.26 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155915E+09 | 64927537.42 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.148060E+09 | 50166650.65 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168604E+09 | 41923293.07 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192815E+09 | 45625411.89 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270344E+09 | 41625333.93 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.388127E+09 | 63999441.62 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416024E+09 | 70971566.42 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434357E+09 | 84310198.95 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.335098E+10 | 0.849428E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.148060E+09 | 41625333.93 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434357E+09 | 0.107380E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.415943E+09 | 0.107380E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.324024E+09 | 93957734.68 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.274210E+09 | 0.101866E+09 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.162557E+09 | 82675464.26 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.155915E+09 | 64927537.42 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.148060E+09 | 50166650.65 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.168604E+09 | 41923293.07 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.192815E+09 | 45625411.89 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.270344E+09 | 41625333.93 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.388127E+09 | 63999441.62 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.416024E+09 | 70971566.42 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.434357E+09 | 84310198.95 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.335098E+10 | 0.849428E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.148060E+09 | 41625333.93 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.434357E+09 | 0.107380E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.494742E+09 | 0.127129E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.385652E+09 | 0.111099E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.326162E+09 | 0.120476E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.193210E+09 | 97918213.76 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.184897E+09 | 76977306.95 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.175563E+09 | 59588689.02 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.199697E+09 | 49827882.48 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.228354E+09 | 54240207.23 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.320752E+09 | 49487311.42 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.460717E+09 | 75975092.75 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.494548E+09 | 84196756.41 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.516696E+09 | 99936682.29 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.398099E+10 | 0.100685E+10 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.175563E+09 | 49487311.42 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.516696E+09 | 0.127129E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414615E+09 | 0.104347E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323073E+09 | 90893506.93 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272539E+09 | 98606086.95 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.160119E+09 | 80313660.39 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.152383E+09 | 64206691.70 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.144571E+09 | 49922922.39 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.164555E+09 | 42585646.16 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.188363E+09 | 46738915.16 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.266888E+09 | 42708034.24 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.384362E+09 | 64755630.26 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413864E+09 | 70063250.10 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.432646E+09 | 82500069.41 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.331798E+10 | 0.837641E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.144571E+09 | 42585646.16 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.432646E+09 | 0.104347E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.146673E+09 | 91960162.19 | 54712961.18 | 0.414615E+09 | 0.104347E+09 |
February | 0.115155E+09 | 62618508.23 | 52536346.48 | 0.323073E+09 | 90893506.93 |
March | 95854154.46 | 36445749.83 | 59408404.64 | 0.272539E+09 | 98606086.95 |
April | 59339610.33 | 8235518.40 | 51104091.93 | 0.160119E+09 | 80313660.39 |
May | 49603502.55 | 268322.79 | 49335179.77 | 0.152383E+09 | 64206691.70 |
June | 47348664.40 | 0.00 | 47348664.40 | 0.144571E+09 | 49922922.39 |
July | 47542882.79 | 231053.11 | 47311829.68 | 0.164555E+09 | 42585646.16 |
August | 53647411.70 | 4937411.68 | 48710000.02 | 0.188363E+09 | 46738915.16 |
September | 80935142.51 | 23455484.54 | 57479657.97 | 0.266888E+09 | 42708034.24 |
October | 0.115952E+09 | 58455703.68 | 57496346.30 | 0.384362E+09 | 64755630.26 |
November | 0.136577E+09 | 78591416.14 | 57985975.37 | 0.413864E+09 | 70063250.10 |
December | 0.150589E+09 | 96551921.12 | 54036672.14 | 0.432646E+09 | 82500069.41 |
Annual Sum or Average | 0.109922E+10 | 0.461751E+09 | 0.637466E+09 | 0.331798E+10 | 0.837641E+09 |
Minimum of Months | 47348664.40 | 0.00 | 47311829.68 | 0.144571E+09 | 42585646.16 |
Maximum of Months | 0.150589E+09 | 96551921.12 | 59408404.64 | 0.432646E+09 | 0.104347E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.175622E+09 | 0.110110E+09 | 65511571.94 | 0.493119E+09 | 0.123583E+09 |
February | 0.137883E+09 | 74977424.33 | 62905362.24 | 0.384499E+09 | 0.107514E+09 |
March | 0.114773E+09 | 43638989.93 | 71133747.66 | 0.324144E+09 | 0.116664E+09 |
April | 71051375.53 | 9860949.66 | 61190425.86 | 0.190269E+09 | 95165390.26 |
May | 59393667.53 | 321281.23 | 59072386.30 | 0.180636E+09 | 76148776.20 |
June | 56693795.54 | 0.00 | 56693795.54 | 0.171351E+09 | 59319909.15 |
July | 56926346.49 | 276655.69 | 56649690.80 | 0.194811E+09 | 50628932.38 |
August | 64235716.64 | 5911900.83 | 58323815.81 | 0.222984E+09 | 55571836.42 |
September | 96909183.80 | 28084856.49 | 68824327.31 | 0.316583E+09 | 50779016.71 |
October | 0.138837E+09 | 69993013.62 | 68844309.39 | 0.456173E+09 | 76889039.20 |
November | 0.163533E+09 | 94102879.86 | 69430575.77 | 0.491924E+09 | 83146973.20 |
December | 0.180310E+09 | 0.115608E+09 | 64701804.80 | 0.514613E+09 | 97828808.55 |
Annual Sum or Average | 0.131617E+10 | 0.552886E+09 | 0.763282E+09 | 0.394111E+10 | 0.993240E+09 |
Minimum of Months | 56693795.54 | 0.00 | 56649690.80 | 0.171351E+09 | 50628932.38 |
Maximum of Months | 0.180310E+09 | 0.115608E+09 | 71133747.66 | 0.514613E+09 | 0.123583E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 989.13 | 261.00 | 350.91 | 220.01 | 130.90 | 0.00 | 0.00 |
February | 852.35 | 253.73 | 305.02 | 165.86 | 139.16 | 0.00 | 0.00 |
March | 649.25 | 247.98 | 229.32 | 87.19 | 142.13 | 0.00 | 0.00 |
April | 394.05 | 207.53 | 146.70 | 20.36 | 126.34 | 0.00 | 0.00 |
May | 365.11 | 154.22 | 118.67 | 0.64 | 118.03 | 0.00 | 0.00 |
June | 357.67 | 123.76 | 117.05 | 0.00 | 117.05 | 0.00 | 0.00 |
July | 396.95 | 95.16 | 113.74 | 0.55 | 113.19 | 0.00 | 0.00 |
August | 452.72 | 107.21 | 128.35 | 11.81 | 116.54 | 0.00 | 0.00 |
September | 663.09 | 98.70 | 200.09 | 57.99 | 142.10 | 0.00 | 0.00 |
October | 922.69 | 148.16 | 277.41 | 139.85 | 137.56 | 0.00 | 0.00 |
November | 1022.13 | 176.29 | 337.64 | 194.29 | 143.35 | 0.00 | 0.00 |
December | 1033.68 | 204.01 | 360.27 | 230.99 | 129.28 | 0.00 | 0.00 |
Annual Sum or Average | 674.16 | 172.72 | 223.35 | 93.82 | 129.53 | 0.00 | 0.00 |
Minimum of Months | 357.67 | 95.16 | 113.74 | 0.00 | 113.19 | 0.00 | 0.00 |
Maximum of Months | 1033.68 | 261.00 | 360.27 | 230.99 | 143.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 491.99 | 132.50 | 175.45 | 110.00 | 65.45 | 0.00 | 0.00 |
February | 423.96 | 128.56 | 152.51 | 82.93 | 69.58 | 0.00 | 0.00 |
March | 323.51 | 125.74 | 114.66 | 43.60 | 71.07 | 0.00 | 0.00 |
April | 196.85 | 105.05 | 73.35 | 10.18 | 63.17 | 0.00 | 0.00 |
May | 183.33 | 77.79 | 59.34 | 0.32 | 59.02 | 0.00 | 0.00 |
June | 179.99 | 61.89 | 58.53 | 0.00 | 58.53 | 0.00 | 0.00 |
July | 200.25 | 47.18 | 56.87 | 0.28 | 56.60 | 0.00 | 0.00 |
August | 228.29 | 53.01 | 64.17 | 5.91 | 58.27 | 0.00 | 0.00 |
September | 333.09 | 48.44 | 100.04 | 28.99 | 71.05 | 0.00 | 0.00 |
October | 461.30 | 74.19 | 138.70 | 69.93 | 68.78 | 0.00 | 0.00 |
November | 509.55 | 88.60 | 168.82 | 97.15 | 71.68 | 0.00 | 0.00 |
December | 514.42 | 103.11 | 180.14 | 115.50 | 64.64 | 0.00 | 0.00 |
Annual Sum or Average | 336.85 | 86.96 | 111.68 | 46.91 | 64.76 | 0.00 | 0.00 |
Minimum of Months | 179.99 | 47.18 | 56.87 | 0.00 | 56.60 | 0.00 | 0.00 |
Maximum of Months | 514.42 | 132.50 | 180.14 | 115.50 | 71.68 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 491.72 | 140.51 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 423.01 | 137.19 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 321.99 | 134.24 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 195.98 | 113.82 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 182.33 | 88.40 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 179.17 | 72.87 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 198.44 | 59.74 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 226.87 | 64.91 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 329.57 | 60.77 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 459.34 | 86.59 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 509.12 | 98.88 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 514.24 | 112.71 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 335.62 | 97.35 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 179.17 | 59.74 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 514.24 | 140.51 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 491.78 | 140.33 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 423.03 | 137.20 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 321.97 | 134.42 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 195.98 | 113.97 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 182.23 | 89.02 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 179.04 | 73.58 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 198.21 | 60.81 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 226.69 | 65.89 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 329.30 | 62.03 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 459.14 | 87.59 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 509.06 | 99.29 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 514.24 | 112.85 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 335.53 | 97.88 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 179.04 | 60.81 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 514.24 | 140.33 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 492.37 | 138.47 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 423.63 | 135.23 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 322.55 | 132.44 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 196.54 | 112.10 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 182.75 | 87.33 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 179.56 | 71.95 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 198.67 | 59.33 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 227.15 | 64.28 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 329.73 | 60.49 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 459.60 | 85.97 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 509.61 | 97.61 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 514.82 | 111.05 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 336.06 | 96.15 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 179.56 | 59.33 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 514.82 | 138.47 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 990.99 | 262.68 | 350.19 | 219.56 | 130.63 | 0.00 | 0.00 |
February | 855.08 | 255.41 | 304.39 | 165.52 | 138.87 | 0.00 | 0.00 |
March | 652.17 | 250.12 | 228.85 | 87.02 | 141.84 | 0.00 | 0.00 |
April | 397.50 | 210.62 | 146.40 | 20.32 | 126.08 | 0.00 | 0.00 |
May | 367.18 | 161.24 | 118.43 | 0.64 | 117.79 | 0.00 | 0.00 |
June | 359.91 | 130.34 | 116.81 | 0.00 | 116.81 | 0.00 | 0.00 |
July | 396.55 | 106.48 | 113.51 | 0.55 | 112.96 | 0.00 | 0.00 |
August | 454.44 | 115.37 | 128.08 | 11.79 | 116.30 | 0.00 | 0.00 |
September | 661.95 | 109.50 | 199.68 | 57.87 | 141.81 | 0.00 | 0.00 |
October | 922.37 | 159.16 | 276.84 | 139.56 | 137.27 | 0.00 | 0.00 |
November | 1023.55 | 181.85 | 336.95 | 193.89 | 143.06 | 0.00 | 0.00 |
December | 1035.32 | 208.10 | 359.53 | 230.52 | 129.01 | 0.00 | 0.00 |
Annual Sum or Average | 675.67 | 178.85 | 222.89 | 93.63 | 129.26 | 0.00 | 0.00 |
Minimum of Months | 359.91 | 106.48 | 113.51 | 0.00 | 112.96 | 0.00 | 0.00 |
Maximum of Months | 1035.32 | 262.68 | 359.53 | 230.52 | 143.06 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 494.57 | 129.41 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 426.56 | 125.55 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 325.96 | 122.89 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 199.50 | 103.16 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 185.09 | 78.32 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 181.62 | 62.68 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 200.21 | 50.68 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 229.09 | 55.00 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 332.15 | 51.98 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 461.59 | 76.99 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 511.24 | 88.49 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 516.61 | 101.75 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 338.32 | 87.04 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 181.62 | 50.68 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 516.61 | 129.41 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 494.95 | 128.70 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 426.94 | 124.77 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 326.31 | 122.13 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 199.84 | 102.46 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 185.45 | 77.71 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 182.00 | 62.08 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 200.58 | 50.11 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 229.43 | 54.43 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 332.49 | 51.37 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 461.93 | 76.39 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 511.62 | 87.84 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 516.98 | 101.07 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 338.68 | 86.39 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 182.00 | 50.11 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 516.98 | 128.70 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 495.31 | 127.65 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 427.29 | 123.60 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 326.53 | 121.05 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 199.97 | 101.57 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 185.46 | 77.22 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 181.98 | 61.70 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 200.46 | 49.91 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 229.24 | 54.32 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 332.35 | 51.21 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 461.83 | 76.15 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 511.80 | 87.25 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 517.25 | 100.27 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 338.75 | 85.80 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 181.98 | 49.91 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 517.25 | 127.65 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 493.71 | 124.06 | 175.09 | 109.78 | 65.31 | 0.00 | 0.00 |
February | 426.03 | 119.59 | 152.20 | 82.76 | 69.44 | 0.00 | 0.00 |
March | 324.53 | 117.19 | 114.43 | 43.51 | 70.92 | 0.00 | 0.00 |
April | 196.95 | 98.69 | 73.20 | 10.16 | 63.04 | 0.00 | 0.00 |
May | 181.23 | 76.37 | 59.21 | 0.32 | 58.89 | 0.00 | 0.00 |
June | 177.66 | 61.41 | 58.41 | 0.00 | 58.41 | 0.00 | 0.00 |
July | 195.61 | 50.70 | 56.75 | 0.28 | 56.48 | 0.00 | 0.00 |
August | 223.91 | 55.65 | 64.04 | 5.89 | 58.15 | 0.00 | 0.00 |
September | 328.07 | 52.54 | 99.84 | 28.93 | 70.90 | 0.00 | 0.00 |
October | 457.32 | 77.06 | 138.42 | 69.78 | 68.64 | 0.00 | 0.00 |
November | 509.12 | 86.14 | 168.48 | 96.95 | 71.53 | 0.00 | 0.00 |
December | 515.20 | 98.13 | 179.77 | 115.26 | 64.51 | 0.00 | 0.00 |
Annual Sum or Average | 335.40 | 84.62 | 111.45 | 46.82 | 64.63 | 0.00 | 0.00 |
Minimum of Months | 177.66 | 50.70 | 56.75 | 0.00 | 56.48 | 0.00 | 0.00 |
Maximum of Months | 515.20 | 124.06 | 179.77 | 115.26 | 71.53 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.264927E+10 | 0.699075E+09 | 0.939866E+09 | 0.589271E+09 | 0.350595E+09 | 0.00 | 0.00 |
February | 0.206200E+10 | 0.613831E+09 | 0.737900E+09 | 0.401253E+09 | 0.336647E+09 | 0.00 | 0.00 |
March | 0.173894E+10 | 0.664195E+09 | 0.614223E+09 | 0.233541E+09 | 0.380683E+09 | 0.00 | 0.00 |
April | 0.102139E+10 | 0.537930E+09 | 0.380242E+09 | 52772335.00 | 0.327470E+09 | 0.00 | 0.00 |
May | 0.977915E+09 | 0.413050E+09 | 0.317854E+09 | 1719384.19 | 0.316135E+09 | 0.00 | 0.00 |
June | 0.927079E+09 | 0.320788E+09 | 0.303405E+09 | 0.00 | 0.303405E+09 | 0.00 | 0.00 |
July | 0.106319E+10 | 0.254878E+09 | 0.304650E+09 | 1480563.99 | 0.303169E+09 | 0.00 | 0.00 |
August | 0.121255E+10 | 0.287157E+09 | 0.343767E+09 | 31638414.32 | 0.312129E+09 | 0.00 | 0.00 |
September | 0.171873E+10 | 0.255828E+09 | 0.518624E+09 | 0.150300E+09 | 0.368324E+09 | 0.00 | 0.00 |
October | 0.247134E+10 | 0.396840E+09 | 0.743009E+09 | 0.374578E+09 | 0.368431E+09 | 0.00 | 0.00 |
November | 0.264936E+10 | 0.456935E+09 | 0.875174E+09 | 0.503606E+09 | 0.371568E+09 | 0.00 | 0.00 |
December | 0.276862E+10 | 0.546417E+09 | 0.964956E+09 | 0.618695E+09 | 0.346261E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.212604E+11 | 0.544692E+10 | 0.704367E+10 | 0.295885E+10 | 0.408482E+10 | 0.00 | 0.00 |
Minimum of Months | 0.927079E+09 | 0.254878E+09 | 0.303405E+09 | 0.00 | 0.303169E+09 | 0.00 | 0.00 |
Maximum of Months | 0.276862E+10 | 0.699075E+09 | 0.964956E+09 | 0.618695E+09 | 0.380683E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.131775E+10 | 0.354899E+09 | 0.469933E+09 | 0.294636E+09 | 0.175297E+09 | 0.00 | 0.00 |
February | 0.102565E+10 | 0.311015E+09 | 0.368950E+09 | 0.200626E+09 | 0.168324E+09 | 0.00 | 0.00 |
March | 0.866498E+09 | 0.336793E+09 | 0.307112E+09 | 0.116770E+09 | 0.190341E+09 | 0.00 | 0.00 |
April | 0.510224E+09 | 0.272291E+09 | 0.190121E+09 | 26386167.50 | 0.163735E+09 | 0.00 | 0.00 |
May | 0.491035E+09 | 0.208361E+09 | 0.158927E+09 | 859692.09 | 0.158067E+09 | 0.00 | 0.00 |
June | 0.466526E+09 | 0.160411E+09 | 0.151703E+09 | 0.00 | 0.151703E+09 | 0.00 | 0.00 |
July | 0.536347E+09 | 0.126363E+09 | 0.152325E+09 | 740282.00 | 0.151585E+09 | 0.00 | 0.00 |
August | 0.611443E+09 | 0.141972E+09 | 0.171883E+09 | 15819207.16 | 0.156064E+09 | 0.00 | 0.00 |
September | 0.863368E+09 | 0.125560E+09 | 0.259312E+09 | 75150137.97 | 0.184162E+09 | 0.00 | 0.00 |
October | 0.123554E+10 | 0.198712E+09 | 0.371504E+09 | 0.187289E+09 | 0.184215E+09 | 0.00 | 0.00 |
November | 0.132075E+10 | 0.229662E+09 | 0.437587E+09 | 0.251803E+09 | 0.185784E+09 | 0.00 | 0.00 |
December | 0.137782E+10 | 0.276183E+09 | 0.482478E+09 | 0.309347E+09 | 0.173131E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.106229E+11 | 0.274222E+10 | 0.352183E+10 | 0.147943E+10 | 0.204241E+10 | 0.00 | 0.00 |
Minimum of Months | 0.466526E+09 | 0.125560E+09 | 0.151703E+09 | 0.00 | 0.151585E+09 | 0.00 | 0.00 |
Maximum of Months | 0.137782E+10 | 0.354899E+09 | 0.482478E+09 | 0.309347E+09 | 0.190341E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.131702E+10 | 0.376341E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.102334E+10 | 0.331892E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.862415E+09 | 0.359549E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.507986E+09 | 0.295027E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.488352E+09 | 0.236773E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.464402E+09 | 0.188889E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.531497E+09 | 0.160013E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.607646E+09 | 0.173851E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.854253E+09 | 0.157504E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.123030E+10 | 0.231927E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.131965E+10 | 0.256298E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.137735E+10 | 0.301888E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.105842E+11 | 0.306995E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.464402E+09 | 0.157504E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.137735E+10 | 0.376341E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.131720E+10 | 0.375873E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.102340E+10 | 0.331922E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.862368E+09 | 0.360019E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.507988E+09 | 0.295413E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.488076E+09 | 0.238444E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.464070E+09 | 0.190709E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.530894E+09 | 0.162876E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.607156E+09 | 0.176481E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.853557E+09 | 0.160774E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.122977E+10 | 0.234600E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.131948E+10 | 0.257351E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.137734E+10 | 0.302261E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.105813E+11 | 0.308672E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.464070E+09 | 0.160774E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.137734E+10 | 0.375873E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.131877E+10 | 0.370874E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.102484E+10 | 0.327152E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.863924E+09 | 0.354736E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.509443E+09 | 0.290563E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.489481E+09 | 0.233916E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.465416E+09 | 0.186498E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.532107E+09 | 0.158900E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.608398E+09 | 0.172163E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.854659E+09 | 0.156800E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.123100E+10 | 0.230253E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.132092E+10 | 0.253006E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.137888E+10 | 0.297436E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.105978E+11 | 0.303230E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.465416E+09 | 0.156800E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.137888E+10 | 0.370874E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.265427E+10 | 0.703575E+09 | 0.937936E+09 | 0.588061E+09 | 0.349875E+09 | 0.00 | 0.00 |
February | 0.206860E+10 | 0.617879E+09 | 0.736385E+09 | 0.400429E+09 | 0.335956E+09 | 0.00 | 0.00 |
March | 0.174676E+10 | 0.669919E+09 | 0.612962E+09 | 0.233061E+09 | 0.379901E+09 | 0.00 | 0.00 |
April | 0.103032E+10 | 0.545914E+09 | 0.379461E+09 | 52663972.92 | 0.326797E+09 | 0.00 | 0.00 |
May | 0.983451E+09 | 0.431878E+09 | 0.317201E+09 | 1715853.62 | 0.315485E+09 | 0.00 | 0.00 |
June | 0.932881E+09 | 0.337848E+09 | 0.302782E+09 | 0.00 | 0.302782E+09 | 0.00 | 0.00 |
July | 0.106213E+10 | 0.285207E+09 | 0.304024E+09 | 1477523.82 | 0.302547E+09 | 0.00 | 0.00 |
August | 0.121716E+10 | 0.309013E+09 | 0.343061E+09 | 31573448.37 | 0.311488E+09 | 0.00 | 0.00 |
September | 0.171578E+10 | 0.283820E+09 | 0.517559E+09 | 0.149992E+09 | 0.367567E+09 | 0.00 | 0.00 |
October | 0.247047E+10 | 0.426287E+09 | 0.741483E+09 | 0.373809E+09 | 0.367674E+09 | 0.00 | 0.00 |
November | 0.265305E+10 | 0.471351E+09 | 0.873376E+09 | 0.502571E+09 | 0.370805E+09 | 0.00 | 0.00 |
December | 0.277299E+10 | 0.557372E+09 | 0.962974E+09 | 0.617424E+09 | 0.345550E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.213079E+11 | 0.564006E+10 | 0.702921E+10 | 0.295278E+10 | 0.407643E+10 | 0.00 | 0.00 |
Minimum of Months | 0.932881E+09 | 0.283820E+09 | 0.302782E+09 | 0.00 | 0.302547E+09 | 0.00 | 0.00 |
Maximum of Months | 0.277299E+10 | 0.703575E+09 | 0.962974E+09 | 0.617424E+09 | 0.379901E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132467E+10 | 0.346618E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.103193E+10 | 0.303719E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.873040E+09 | 0.329152E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.517094E+09 | 0.267382E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.495736E+09 | 0.209783E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.470754E+09 | 0.162455E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.536241E+09 | 0.135746E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.613601E+09 | 0.147316E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.860941E+09 | 0.134732E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.123632E+10 | 0.206204E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.132513E+10 | 0.229359E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.138368E+10 | 0.272536E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.106691E+11 | 0.274500E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.470754E+09 | 0.134732E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.138368E+10 | 0.346618E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132566E+10 | 0.344718E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.103286E+10 | 0.301852E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.873985E+09 | 0.327121E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.517978E+09 | 0.265573E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.496716E+09 | 0.208137E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.471740E+09 | 0.160924E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.537225E+09 | 0.134207E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.614508E+09 | 0.145797E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.861820E+09 | 0.133159E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.123722E+10 | 0.204594E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.132612E+10 | 0.227686E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.138469E+10 | 0.270704E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.106805E+11 | 0.272447E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.471740E+09 | 0.133159E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.138469E+10 | 0.344718E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132663E+10 | 0.341888E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.103370E+10 | 0.299014E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.874582E+09 | 0.324207E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.518324E+09 | 0.263269E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.496726E+09 | 0.206832E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.471683E+09 | 0.159922E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.536905E+09 | 0.133674E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.613985E+09 | 0.145491E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.861440E+09 | 0.132738E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.123697E+10 | 0.203974E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.132660E+10 | 0.226140E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.138541E+10 | 0.268557E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.106829E+11 | 0.270571E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.471683E+09 | 0.132738E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.138541E+10 | 0.341888E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132235E+10 | 0.332277E+09 | 0.468968E+09 | 0.294031E+09 | 0.174937E+09 | 0.00 | 0.00 |
February | 0.103064E+10 | 0.289301E+09 | 0.368192E+09 | 0.200214E+09 | 0.167978E+09 | 0.00 | 0.00 |
March | 0.869221E+09 | 0.313877E+09 | 0.306481E+09 | 0.116530E+09 | 0.189951E+09 | 0.00 | 0.00 |
April | 0.510507E+09 | 0.255793E+09 | 0.189731E+09 | 26331986.46 | 0.163399E+09 | 0.00 | 0.00 |
May | 0.485403E+09 | 0.204562E+09 | 0.158601E+09 | 857926.81 | 0.157743E+09 | 0.00 | 0.00 |
June | 0.460493E+09 | 0.159166E+09 | 0.151391E+09 | 0.00 | 0.151391E+09 | 0.00 | 0.00 |
July | 0.523922E+09 | 0.135800E+09 | 0.152012E+09 | 738761.91 | 0.151273E+09 | 0.00 | 0.00 |
August | 0.599710E+09 | 0.149049E+09 | 0.171531E+09 | 15786724.19 | 0.155744E+09 | 0.00 | 0.00 |
September | 0.850360E+09 | 0.136195E+09 | 0.258779E+09 | 74995825.57 | 0.183784E+09 | 0.00 | 0.00 |
October | 0.122490E+10 | 0.206400E+09 | 0.370741E+09 | 0.186904E+09 | 0.183837E+09 | 0.00 | 0.00 |
November | 0.131965E+10 | 0.223273E+09 | 0.436688E+09 | 0.251286E+09 | 0.185403E+09 | 0.00 | 0.00 |
December | 0.137991E+10 | 0.262829E+09 | 0.481487E+09 | 0.308712E+09 | 0.172775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.105771E+11 | 0.266852E+10 | 0.351460E+10 | 0.147639E+10 | 0.203821E+10 | 0.00 | 0.00 |
Minimum of Months | 0.460493E+09 | 0.135800E+09 | 0.151391E+09 | 0.00 | 0.151273E+09 | 0.00 | 0.00 |
Maximum of Months | 0.137991E+10 | 0.332277E+09 | 0.481487E+09 | 0.308712E+09 | 0.189951E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 22.49 | 18.25 | 15.90 | 4.15 | 13.31 | 59.87 | 181.51 | 0.00 |
February | 22.80 | 19.74 | 18.20 | 3.70 | 14.21 | 74.30 | 182.84 | 0.03 |
March | 23.17 | 18.99 | 16.85 | 4.23 | 14.23 | 89.51 | 186.76 | 0.02 |
April | 23.76 | 19.01 | 16.50 | 4.83 | 14.94 | 95.22 | 199.35 | 0.00 |
May | 25.23 | 20.49 | 18.23 | 4.38 | 17.08 | 98.73 | 213.00 | 0.00 |
June | 25.87 | 20.89 | 18.70 | 5.87 | 17.20 | 99.16 | 227.55 | 0.00 |
July | 26.90 | 21.77 | 19.49 | 5.98 | 18.80 | 89.26 | 241.04 | 0.00 |
August | 27.06 | 21.88 | 19.61 | 5.21 | 18.26 | 83.09 | 253.22 | 0.00 |
September | 26.87 | 22.30 | 20.37 | 5.44 | 18.71 | 93.82 | 214.78 | 0.00 |
October | 26.22 | 21.67 | 19.68 | 3.78 | 17.26 | 74.41 | 199.79 | 0.00 |
November | 24.76 | 20.57 | 18.62 | 5.17 | 16.20 | 67.97 | 175.93 | 0.00 |
December | 23.69 | 19.64 | 17.67 | 4.42 | 14.96 | 56.37 | 177.80 | 0.00 |
Annual Sum or Average | 24.91 | 20.44 | 18.32 | 4.77 | 16.27 | 81.79 | 204.64 | 0.00 |
Minimum of Months | 22.49 | 18.25 | 15.90 | 3.70 | 13.31 | 56.37 | 175.93 | 0.00 |
Maximum of Months | 27.06 | 22.30 | 20.37 | 5.98 | 18.80 | 99.16 | 253.22 | 0.03 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 29.40 | 03-JAN-12:00 | 22.05 | 18.90 | 3.60 | 19.35 | 145.50 | 575.00 |
February | 28.90 | 19-FEB-10:00 | 22.34 | 19.40 | 3.10 | 18.28 | 204.00 | 595.50 |
March | 30.00 | 29-MAR-12:00 | 20.05 | 15.00 | 6.70 | 20.22 | 350.50 | 543.50 |
April | 30.00 | 09-APR-13:00 | 20.06 | 15.00 | 7.20 | 17.39 | 126.00 | 778.50 |
May | 31.10 | 17-MAY-13:20 | 21.31 | 16.70 | 7.87 | 22.12 | 283.17 | 716.50 |
June | 30.60 | 26-JUN-13:00 | 21.72 | 17.80 | 6.70 | 20.40 | 162.00 | 756.50 |
July | 32.20 | 09-JUL-11:00 | 23.42 | 20.00 | 6.20 | 23.49 | 235.00 | 733.00 |
August | 32.80 | 11-AUG-13:00 | 23.28 | 19.40 | 6.20 | 23.99 | 228.00 | 563.00 |
September | 33.30 | 02-SEP-12:00 | 23.47 | 19.40 | 5.70 | 23.32 | 185.00 | 789.00 |
October | 33.30 | 01-OCT-12:00 | 23.04 | 18.90 | 6.20 | 23.15 | 143.50 | 854.50 |
November | 30.60 | 03-NOV-12:00 | 22.49 | 18.90 | 7.70 | 20.57 | 148.00 | 798.50 |
December | 30.60 | 13-DEC-13:00 | 22.11 | 18.30 | 5.70 | 18.64 | 59.00 | 832.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 28.90 | 20.05 | 15.00 | 3.10 | 17.39 | 59.00 | 543.50 | |
Maximum of Months | 33.30 | 23.47 | 20.00 | 7.87 | 23.99 | 350.50 | 854.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 17.20 | 07-JAN-06:00 | 15.82 | 15.00 | 1.50 | 3.89 | 0.00 | 0.00 |
February | 13.30 | 12-FEB-06:00 | 12.64 | 12.20 | 3.10 | 0.73 | 0.00 | 0.00 |
March | 15.00 | 08-MAR-03:00 | 13.29 | 12.20 | 0.00 | 1.16 | 0.00 | 0.00 |
April | 17.80 | 22-APR-02:00 | 16.39 | 15.60 | 0.00 | 6.75 | 0.00 | 0.00 |
May | 18.90 | 23-MAY-05:00 | 17.45 | 16.70 | 2.10 | 9.33 | 110.00 | 159.50 |
June | 21.10 | 06-JUN-04:00 | 19.20 | 18.30 | 2.60 | 9.52 | 0.00 | 0.00 |
July | 22.20 | 09-JUL-03:00 | 20.00 | 18.90 | 1.50 | 11.84 | 0.00 | 0.00 |
August | 21.10 | 18-AUG-05:00 | 19.93 | 19.40 | 2.10 | 8.54 | 0.00 | 0.00 |
September | 22.20 | 19-SEP-04:00 | 20.25 | 19.40 | 2.60 | 11.84 | 0.00 | 0.00 |
October | 19.40 | 19-OCT-05:00 | 17.58 | 16.70 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 16.10 | 27-NOV-06:00 | 15.39 | 15.00 | 2.60 | 5.74 | 50.00 | 566.00 |
December | 16.70 | 26-DEC-01:00 | 15.01 | 13.90 | 2.60 | 4.31 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 13.30 | 12.64 | 12.20 | 0.00 | 0.73 | 0.00 | 0.00 | |
Maximum of Months | 22.20 | 20.25 | 19.40 | 3.10 | 11.84 | 110.00 | 566.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 23.03 | 01-JAN-15:00 | 27.80 | 21.10 | 4.10 | 20.92 | 91.00 | 199.00 |
February | 24.57 | 18-FEB-13:00 | 27.80 | 23.30 | 4.10 | 21.44 | 268.00 | 307.00 |
March | 23.81 | 13-MAR-12:00 | 27.80 | 22.20 | 5.70 | 22.47 | 468.50 | 259.00 |
April | 22.82 | 24-APR-11:00 | 28.30 | 20.60 | 4.60 | 19.87 | 357.00 | 446.00 |
May | 23.35 | 08-MAY-15:00 | 28.90 | 21.10 | 6.20 | 22.13 | 182.00 | 323.50 |
June | 23.02 | 20-JUN-13:00 | 28.90 | 20.60 | 7.70 | 21.96 | 370.50 | 346.50 |
July | 24.68 | 20-JUL-13:00 | 26.70 | 23.90 | 8.20 | 25.33 | 309.00 | 14.00 |
August | 25.47 | 19-AUG-14:00 | 31.70 | 23.30 | 5.20 | 25.33 | 229.00 | 409.00 |
September | 25.16 | 23-SEP-14:00 | 27.20 | 24.40 | 4.10 | 23.82 | 288.00 | 450.00 |
October | 24.72 | 15-OCT-13:00 | 31.70 | 22.20 | 5.20 | 22.98 | 151.50 | 527.00 |
November | 23.46 | 02-NOV-09:00 | 29.40 | 21.10 | 6.20 | 20.57 | 236.50 | 546.50 |
December | 23.69 | 03-DEC-10:00 | 26.10 | 22.80 | 6.70 | 24.50 | 251.50 | 3.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 22.82 | 26.10 | 20.60 | 4.10 | 19.87 | 91.00 | 3.00 | |
Maximum of Months | 25.47 | 31.70 | 24.40 | 8.20 | 25.33 | 468.50 | 546.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.10 | 01-JAN-15:00 | 27.80 | 23.03 | 4.10 | 20.92 | 91.00 | 199.00 |
February | 23.30 | 16-FEB-17:00 | 24.40 | 23.65 | 3.10 | 22.98 | 29.50 | 4.00 |
March | 22.20 | 13-MAR-10:00 | 27.20 | 23.57 | 4.60 | 21.78 | 336.00 | 148.00 |
April | 21.10 | 24-APR-23:00 | 22.80 | 21.58 | 1.50 | 18.82 | 0.00 | 0.00 |
May | 22.20 | 09-MAY-23:00 | 24.40 | 22.88 | 1.50 | 22.64 | 0.00 | 0.00 |
June | 20.80 | 09-JUN-00:10 | 22.15 | 21.03 | 3.78 | 18.14 | 0.00 | 0.00 |
July | 23.90 | 20-JUL-13:00 | 26.70 | 24.68 | 8.20 | 25.33 | 309.00 | 14.00 |
August | 23.30 | 19-AUG-14:00 | 31.70 | 25.47 | 5.20 | 25.33 | 229.00 | 409.00 |
September | 24.40 | 23-SEP-14:00 | 27.20 | 25.16 | 4.10 | 23.82 | 288.00 | 450.00 |
October | 22.80 | 24-OCT-12:00 | 26.10 | 23.69 | 4.10 | 19.70 | 259.00 | 474.50 |
November | 21.70 | 29-NOV-17:00 | 26.10 | 22.98 | 3.10 | 22.13 | 0.00 | 0.00 |
December | 22.80 | 03-DEC-10:00 | 26.10 | 23.69 | 6.70 | 24.50 | 251.50 | 3.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.80 | 22.15 | 21.03 | 1.50 | 18.14 | 0.00 | 0.00 | |
Maximum of Months | 24.40 | 31.70 | 25.47 | 8.20 | 25.33 | 336.00 | 474.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 26.59 | 31.34 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 26.78 | 37.09 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 27.35 | 43.34 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 28.17 | 47.38 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 29.01 | 50.82 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 29.64 | 52.70 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 29.90 | 53.08 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 29.71 | 53.00 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 29.13 | 48.47 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 28.31 | 39.62 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 27.47 | 33.78 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 26.84 | 30.10 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 28.25 | 43.42 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 26.59 | 30.10 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 29.90 | 53.08 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.271108E+09 | -159028652.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112079022.2 | 59.00 | 0.00 | 0.00 |
February | 0.244749E+09 | -143582527.0 | 0.00 | 0.00 | 672.00 | 0.00 | -101166497.0 | 58.99 | 0.00 | 0.00 |
March | 0.270604E+09 | -158627767.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111975856.4 | 58.99 | 0.00 | 0.00 |
April | 0.256145E+09 | -147848238.8 | 0.00 | 0.00 | 720.00 | 0.00 | -108296744.8 | 58.99 | 0.00 | 0.00 |
May | 0.260304E+09 | -148724609.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111579858.2 | 58.99 | 0.00 | 0.00 |
June | 0.250020E+09 | -142214285.9 | 0.00 | 0.00 | 720.00 | 0.00 | -107805737.9 | 58.99 | 0.00 | 0.00 |
July | 0.254054E+09 | -142895024.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111158829.8 | 58.99 | 0.00 | 0.00 |
August | 0.257805E+09 | -146661493.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111143673.2 | 58.99 | 0.00 | 0.00 |
September | 0.250790E+09 | -143351177.5 | 0.00 | 0.00 | 720.00 | 0.00 | -107438953.9 | 58.99 | 0.00 | 0.00 |
October | 0.262002E+09 | -150655959.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111346365.6 | 58.99 | 0.00 | 0.00 |
November | 0.257296E+09 | -149370510.8 | 0.00 | 0.00 | 720.00 | 0.00 | -107925545.5 | 58.99 | 0.00 | 0.00 |
December | 0.269820E+09 | -158057295.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111762383.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.310470E+10 | -.179102E+10 | 8760.00 | -.131368E+10 | 58.99 | |||||
Minimum of Months | 0.244749E+09 | -159028652.4 | 0.00 | 0.00 | 672.00 | 0.00 | -112079022.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.271108E+09 | -142214285.9 | 0.00 | 0.00 | 744.00 | 0.00 | -101166497.0 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.270863E+09 | -159036552.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111826857.0 | 58.99 | 0.00 | 0.00 |
February | 0.244550E+09 | -143588864.8 | 0.00 | 0.00 | 672.00 | 0.00 | -100960716.3 | 58.99 | 0.00 | 0.00 |
March | 0.270398E+09 | -158616307.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111781756.4 | 58.99 | 0.00 | 0.00 |
April | 0.255937E+09 | -147826593.9 | 0.00 | 0.00 | 720.00 | 0.00 | -108110088.0 | 58.99 | 0.00 | 0.00 |
May | 0.260137E+09 | -148718694.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111418706.3 | 58.99 | 0.00 | 0.00 |
June | 0.249888E+09 | -142219352.0 | 0.00 | 0.00 | 720.00 | 0.00 | -107669109.0 | 58.99 | 0.00 | 0.00 |
July | 0.253951E+09 | -142893548.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111057666.1 | 58.99 | 0.00 | 0.00 |
August | 0.257724E+09 | -146665307.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111058642.9 | 58.99 | 0.00 | 0.00 |
September | 0.250738E+09 | -143347306.4 | 0.00 | 0.00 | 720.00 | 0.00 | -107390478.4 | 58.99 | 0.00 | 0.00 |
October | 0.261888E+09 | -150647918.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111240111.3 | 58.99 | 0.00 | 0.00 |
November | 0.257133E+09 | -149375327.4 | 0.00 | 0.00 | 720.00 | 0.00 | -107757974.8 | 58.99 | 0.00 | 0.00 |
December | 0.269625E+09 | -158051932.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111572682.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.310283E+10 | -.179099E+10 | 8760.00 | -.131184E+10 | 58.99 | |||||
Minimum of Months | 0.244550E+09 | -159036552.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111826857.0 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.270863E+09 | -142219352.0 | 0.00 | 0.00 | 744.00 | 0.00 | -100960716.3 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.250256E+09 | -139864120.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110391797.8 | 58.99 | 0.00 | 0.00 |
February | 0.225900E+09 | -126372756.4 | 0.00 | 0.00 | 672.00 | 0.00 | -99527108.8 | 58.99 | 0.00 | 0.00 |
March | 0.251813E+09 | -141670166.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110142959.0 | 58.99 | 0.00 | 0.00 |
April | 0.236382E+09 | -129913250.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106469187.2 | 58.99 | 0.00 | 0.00 |
May | 0.241334E+09 | -131893263.5 | 0.00 | 0.00 | 744.00 | 0.00 | -109440745.2 | 58.99 | 0.00 | 0.00 |
June | 0.232478E+09 | -126757256.2 | 0.00 | 0.00 | 720.00 | 0.00 | -105720604.9 | 58.99 | 0.00 | 0.00 |
July | 0.233538E+09 | -124850062.7 | 0.00 | 0.00 | 744.00 | 0.00 | -108688280.7 | 58.99 | 0.00 | 0.00 |
August | 0.239977E+09 | -131098533.8 | 0.00 | 0.00 | 744.00 | 0.00 | -108878369.3 | 58.99 | 0.00 | 0.00 |
September | 0.230888E+09 | -125889458.3 | 0.00 | 0.00 | 720.00 | 0.00 | -104998063.5 | 58.99 | 0.00 | 0.00 |
October | 0.241433E+09 | -132498612.4 | 0.00 | 0.00 | 744.00 | 0.00 | -108934314.1 | 58.99 | 0.00 | 0.00 |
November | 0.237894E+09 | -131887426.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106006498.3 | 58.99 | 0.00 | 0.00 |
December | 0.247861E+09 | -137978458.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109882588.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.286975E+10 | -.158067E+10 | 8760.00 | -.128908E+10 | 58.99 | |||||
Minimum of Months | 0.225900E+09 | -141670166.9 | 0.00 | 0.00 | 672.00 | 0.00 | -110391797.8 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.251813E+09 | -124850062.7 | 0.00 | 0.00 | 744.00 | 0.00 | -99527108.8 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.250268E+09 | -139864552.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110403108.1 | 58.99 | 0.00 | 0.00 |
February | 0.225897E+09 | -126372188.6 | 0.00 | 0.00 | 672.00 | 0.00 | -99524698.4 | 58.99 | 0.00 | 0.00 |
March | 0.251798E+09 | -141669734.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110128478.3 | 58.99 | 0.00 | 0.00 |
April | 0.236369E+09 | -129914525.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106454797.8 | 58.99 | 0.00 | 0.00 |
May | 0.241284E+09 | -131893415.5 | 0.00 | 0.00 | 744.00 | 0.00 | -109390874.8 | 58.99 | 0.00 | 0.00 |
June | 0.232420E+09 | -126763826.1 | 0.00 | 0.00 | 720.00 | 0.00 | -105656297.7 | 58.99 | 0.00 | 0.00 |
July | 0.233452E+09 | -124855970.7 | 0.00 | 0.00 | 744.00 | 0.00 | -108596214.6 | 58.99 | 0.00 | 0.00 |
August | 0.239886E+09 | -131091492.3 | 0.00 | 0.00 | 744.00 | 0.00 | -108794205.0 | 58.99 | 0.00 | 0.00 |
September | 0.230785E+09 | -125884713.8 | 0.00 | 0.00 | 720.00 | 0.00 | -104900332.6 | 58.99 | 0.00 | 0.00 |
October | 0.241355E+09 | -132490817.2 | 0.00 | 0.00 | 744.00 | 0.00 | -108864647.1 | 58.99 | 0.00 | 0.00 |
November | 0.237867E+09 | -131869263.7 | 0.00 | 0.00 | 720.00 | 0.00 | -105997975.7 | 58.99 | 0.00 | 0.00 |
December | 0.247835E+09 | -137965146.7 | 0.00 | 0.00 | 744.00 | 0.00 | -109869900.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.286922E+10 | -.158064E+10 | 8760.00 | -.128858E+10 | 58.99 | |||||
Minimum of Months | 0.225897E+09 | -141669734.0 | 0.00 | 0.00 | 672.00 | 0.00 | -110403108.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.251798E+09 | -124855970.7 | 0.00 | 0.00 | 744.00 | 0.00 | -99524698.4 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.243273E+09 | -132173884.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111098802.9 | 58.99 | 0.00 | 0.00 |
February | 0.219686E+09 | -119488671.1 | 0.00 | 0.00 | 672.00 | 0.00 | -100197192.6 | 59.00 | 0.00 | 0.00 |
March | 0.244961E+09 | -134050090.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110910751.2 | 58.99 | 0.00 | 0.00 |
April | 0.230111E+09 | -122956476.6 | 0.00 | 0.00 | 720.00 | 0.00 | -107154721.9 | 58.99 | 0.00 | 0.00 |
May | 0.234858E+09 | -124735167.5 | 0.00 | 0.00 | 744.00 | 0.00 | -110123228.5 | 58.99 | 0.00 | 0.00 |
June | 0.226315E+09 | -119949457.4 | 0.00 | 0.00 | 720.00 | 0.00 | -106365502.2 | 58.99 | 0.00 | 0.00 |
July | 0.227281E+09 | -118072559.5 | 0.00 | 0.00 | 744.00 | 0.00 | -109208923.3 | 58.99 | 0.00 | 0.00 |
August | 0.233576E+09 | -124044972.8 | 0.00 | 0.00 | 744.00 | 0.00 | -109530622.5 | 58.99 | 0.00 | 0.00 |
September | 0.224641E+09 | -119107876.2 | 0.00 | 0.00 | 720.00 | 0.00 | -105532689.4 | 59.00 | 0.00 | 0.00 |
October | 0.234789E+09 | -125230737.0 | 0.00 | 0.00 | 744.00 | 0.00 | -109558081.2 | 58.99 | 0.00 | 0.00 |
November | 0.231198E+09 | -124558916.4 | 0.00 | 0.00 | 720.00 | 0.00 | -106638753.1 | 58.99 | 0.00 | 0.00 |
December | 0.241032E+09 | -130493694.4 | 0.00 | 0.00 | 744.00 | 0.00 | -110538520.0 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.279172E+10 | -.149486E+10 | 8760.00 | -.129686E+10 | 58.99 | |||||
Minimum of Months | 0.219686E+09 | -134050090.8 | 0.00 | 0.00 | 672.00 | 0.00 | -111098802.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.244961E+09 | -118072559.5 | 0.00 | 0.00 | 744.00 | 0.00 | -100197192.6 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.243411E+09 | -132177406.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111233688.7 | 58.99 | 0.00 | 0.00 |
February | 0.219815E+09 | -119508237.6 | 0.00 | 0.00 | 672.00 | 0.00 | -100307160.6 | 58.99 | 0.00 | 0.00 |
March | 0.245099E+09 | -134045794.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111053400.9 | 58.99 | 0.00 | 0.00 |
April | 0.230258E+09 | -122920690.1 | 0.00 | 0.00 | 720.00 | 0.00 | -107337802.5 | 59.00 | 0.00 | 0.00 |
May | 0.235030E+09 | -124726424.2 | 0.00 | 0.00 | 744.00 | 0.00 | -110303173.2 | 58.99 | 0.00 | 0.00 |
June | 0.226478E+09 | -119951183.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106526630.2 | 58.99 | 0.00 | 0.00 |
July | 0.227473E+09 | -118077763.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109395401.8 | 58.99 | 0.00 | 0.00 |
August | 0.233757E+09 | -124045446.0 | 0.00 | 0.00 | 744.00 | 0.00 | -109711858.4 | 58.99 | 0.00 | 0.00 |
September | 0.224824E+09 | -119116082.1 | 0.00 | 0.00 | 720.00 | 0.00 | -105707573.1 | 58.99 | 0.00 | 0.00 |
October | 0.234978E+09 | -125239833.3 | 0.00 | 0.00 | 744.00 | 0.00 | -109738649.3 | 58.99 | 0.00 | 0.00 |
November | 0.231341E+09 | -124569784.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106771162.9 | 58.98 | 0.00 | 0.00 |
December | 0.241200E+09 | -130488216.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110711323.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.279366E+10 | -.149487E+10 | 8760.00 | -.129880E+10 | 58.99 | |||||
Minimum of Months | 0.219815E+09 | -134045794.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111233688.7 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.245099E+09 | -118077763.2 | 0.00 | 0.00 | 744.00 | 0.00 | -100307160.6 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.243469E+09 | -132176730.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111292229.2 | 59.00 | 0.00 | 0.00 |
February | 0.219867E+09 | -119514923.3 | 0.00 | 0.00 | 672.00 | 0.00 | -100352015.1 | 58.99 | 0.00 | 0.00 |
March | 0.245161E+09 | -134048444.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111112150.9 | 58.99 | 0.00 | 0.00 |
April | 0.230306E+09 | -122924832.4 | 0.00 | 0.00 | 720.00 | 0.00 | -107381165.3 | 58.99 | 0.00 | 0.00 |
May | 0.235087E+09 | -124729085.7 | 0.00 | 0.00 | 744.00 | 0.00 | -110357727.9 | 58.99 | 0.00 | 0.00 |
June | 0.226531E+09 | -119959024.7 | 0.00 | 0.00 | 720.00 | 0.00 | -106572262.1 | 58.99 | 0.00 | 0.00 |
July | 0.227516E+09 | -118072972.0 | 0.00 | 0.00 | 744.00 | 0.00 | -109442959.4 | 58.99 | 0.00 | 0.00 |
August | 0.233808E+09 | -124051643.1 | 0.00 | 0.00 | 744.00 | 0.00 | -109756546.9 | 58.99 | 0.00 | 0.00 |
September | 0.224879E+09 | -119142731.2 | 0.00 | 0.00 | 720.00 | 0.00 | -105735774.2 | 58.99 | 0.00 | 0.00 |
October | 0.235023E+09 | -125204974.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109818206.1 | 59.00 | 0.00 | 0.00 |
November | 0.231404E+09 | -124544537.6 | 0.00 | 0.00 | 720.00 | 0.00 | -106859066.1 | 58.99 | 0.00 | 0.00 |
December | 0.241242E+09 | -130499467.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110742489.5 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.279429E+10 | -.149487E+10 | 8760.00 | -.129942E+10 | 58.99 | |||||
Minimum of Months | 0.219867E+09 | -134048444.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111292229.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.245161E+09 | -118072972.0 | 0.00 | 0.00 | 744.00 | 0.00 | -100352015.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 326.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 285.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 336.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 360.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 384.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 392.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 398.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 382.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 359.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 346.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 316.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 318.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4207.17 | ||||||||||
Minimum of Months | 285.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 398.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.324611E+11 | 0.239877E+11 | 57221.54 | 31-JAN-08:62 | 32676.22 | 0.00 |
February | 0.00 | 0.00 | 0.337832E+11 | 0.228746E+11 | 59200.10 | 18-FEB-08:62 | 28679.30 | 0.00 |
March | 0.00 | 0.00 | 0.359792E+11 | 0.260941E+11 | 57546.51 | 03-MAR-08:62 | 30339.69 | 0.00 |
April | 0.00 | 0.00 | 0.344289E+11 | 0.255498E+11 | 56204.94 | 25-APR-07:02 | 36737.12 | 0.00 |
May | 0.00 | 0.00 | 0.422413E+11 | 0.302250E+11 | 58118.52 | 10-MAY-07:02 | 31984.84 | 0.00 |
June | 0.00 | 0.00 | 0.427808E+11 | 0.303813E+11 | 57661.32 | 14-JUN-07:02 | 33581.88 | 0.00 |
July | 0.00 | 0.00 | 0.490270E+11 | 0.342161E+11 | 59393.32 | 20-JUL-07:01 | 29828.72 | 0.00 |
August | 0.00 | 0.00 | 0.496584E+11 | 0.348493E+11 | 58384.24 | 08-AUG-07:01 | 32412.89 | 0.00 |
September | 0.00 | 0.00 | 0.497109E+11 | 0.337442E+11 | 58917.58 | 30-SEP-07:02 | 29918.81 | 0.00 |
October | 0.00 | 0.00 | 0.483728E+11 | 0.335357E+11 | 58126.23 | 13-OCT-07:02 | 32751.12 | 0.00 |
November | 0.00 | 0.00 | 0.410804E+11 | 0.286549E+11 | 58266.85 | 01-NOV-07:02 | 32022.83 | 0.00 |
December | 0.00 | 0.00 | 0.379478E+11 | 0.267459E+11 | 58501.80 | 03-DEC-08:61 | 32531.24 | 0.00 |
Annual Sum or Average | 0.497472E+12 | 0.350859E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.324611E+11 | 0.228746E+11 | 56204.94 | 28679.30 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.497109E+11 | 0.348493E+11 | 59393.32 | 36737.12 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.168845E+11 | 0.128576E+11 | 29421.25 | 31-JAN-08:62 | 19390.65 | 0.00 |
February | 0.00 | 0.00 | 0.172284E+11 | 0.120820E+11 | 30275.74 | 17-FEB-08:62 | 17249.41 | 0.00 |
March | 0.00 | 0.00 | 0.183797E+11 | 0.137142E+11 | 29533.28 | 03-MAR-08:62 | 18349.38 | 0.00 |
April | 0.00 | 0.00 | 0.174901E+11 | 0.133423E+11 | 29047.38 | 17-APR-07:02 | 20605.57 | 0.00 |
May | 0.00 | 0.00 | 0.211681E+11 | 0.155786E+11 | 29763.61 | 10-MAY-07:02 | 19178.87 | 0.00 |
June | 0.00 | 0.00 | 0.212662E+11 | 0.155047E+11 | 29739.77 | 14-JUN-07:02 | 19294.15 | 0.00 |
July | 0.00 | 0.00 | 0.241287E+11 | 0.173148E+11 | 30539.72 | 20-JUL-07:01 | 17478.14 | 0.00 |
August | 0.00 | 0.00 | 0.244662E+11 | 0.176321E+11 | 30056.28 | 08-AUG-07:01 | 18727.08 | 0.00 |
September | 0.00 | 0.00 | 0.242556E+11 | 0.169425E+11 | 30224.21 | 30-SEP-07:02 | 17905.17 | 0.00 |
October | 0.00 | 0.00 | 0.240474E+11 | 0.171744E+11 | 29848.70 | 13-OCT-07:02 | 19131.18 | 0.00 |
November | 0.00 | 0.00 | 0.206452E+11 | 0.148395E+11 | 30028.41 | 01-NOV-07:02 | 18563.94 | 0.00 |
December | 0.00 | 0.00 | 0.193106E+11 | 0.140581E+11 | 30276.84 | 03-DEC-08:61 | 18366.74 | 0.00 |
Annual Sum or Average | 0.249271E+12 | 0.181041E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.168845E+11 | 0.120820E+11 | 29047.38 | 17249.41 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.244662E+11 | 0.176321E+11 | 30539.72 | 20605.57 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.135531E+11 | 0.100850E+11 | 30161.11 | 02-JAN-07:02 | 17418.25 | 0.00 |
February | 0.00 | 0.00 | 0.139345E+11 | 0.948507E+10 | 31182.24 | 18-FEB-07:02 | 14568.77 | 0.00 |
March | 0.00 | 0.00 | 0.149464E+11 | 0.108907E+11 | 30631.32 | 13-MAR-06:02 | 16122.63 | 0.00 |
April | 0.00 | 0.00 | 0.140703E+11 | 0.104828E+11 | 30054.35 | 24-APR-06:02 | 17102.25 | 0.00 |
May | 0.00 | 0.00 | 0.174350E+11 | 0.125437E+11 | 30596.74 | 15-MAY-06:02 | 15881.88 | 0.00 |
June | 0.00 | 0.00 | 0.176565E+11 | 0.125555E+11 | 30186.82 | 18-JUN-07:01 | 18389.70 | 0.00 |
July | 0.00 | 0.00 | 0.198308E+11 | 0.138826E+11 | 31103.26 | 23-JUL-07:01 | 16061.50 | 0.00 |
August | 0.00 | 0.00 | 0.205285E+11 | 0.144796E+11 | 30815.42 | 20-AUG-07:01 | 16628.88 | 0.00 |
September | 0.00 | 0.00 | 0.199159E+11 | 0.135425E+11 | 31293.85 | 25-SEP-06:01 | 14828.80 | 0.00 |
October | 0.00 | 0.00 | 0.198580E+11 | 0.138513E+11 | 30661.93 | 01-OCT-07:01 | 16372.69 | 0.00 |
November | 0.00 | 0.00 | 0.170522E+11 | 0.119563E+11 | 30460.75 | 06-NOV-07:01 | 17351.95 | 0.00 |
December | 0.00 | 0.00 | 0.156399E+11 | 0.110830E+11 | 30701.19 | 03-DEC-08:61 | 17081.29 | 0.00 |
Annual Sum or Average | 0.204421E+12 | 0.144838E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.135531E+11 | 0.948507E+10 | 30054.35 | 14568.77 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.205285E+11 | 0.144796E+11 | 31293.85 | 18389.70 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.135322E+11 | 0.100698E+11 | 30217.22 | 02-JAN-07:02 | 17478.16 | 0.00 |
February | 0.00 | 0.00 | 0.139255E+11 | 0.947989E+10 | 31236.53 | 18-FEB-07:02 | 14597.07 | 0.00 |
March | 0.00 | 0.00 | 0.149493E+11 | 0.108949E+11 | 30689.41 | 13-MAR-06:02 | 16185.07 | 0.00 |
April | 0.00 | 0.00 | 0.140695E+11 | 0.104837E+11 | 30108.21 | 24-APR-06:02 | 17147.47 | 0.00 |
May | 0.00 | 0.00 | 0.174640E+11 | 0.125697E+11 | 30655.40 | 15-MAY-06:02 | 15953.35 | 0.00 |
June | 0.00 | 0.00 | 0.176892E+11 | 0.125846E+11 | 30245.47 | 18-JUN-07:01 | 18463.22 | 0.00 |
July | 0.00 | 0.00 | 0.198899E+11 | 0.139334E+11 | 31163.80 | 23-JUL-07:01 | 16137.07 | 0.00 |
August | 0.00 | 0.00 | 0.205825E+11 | 0.145263E+11 | 30877.26 | 20-AUG-07:01 | 16713.76 | 0.00 |
September | 0.00 | 0.00 | 0.199879E+11 | 0.136029E+11 | 31359.68 | 25-SEP-06:01 | 14938.47 | 0.00 |
October | 0.00 | 0.00 | 0.199171E+11 | 0.139015E+11 | 30721.23 | 01-OCT-07:01 | 16445.49 | 0.00 |
November | 0.00 | 0.00 | 0.170653E+11 | 0.119693E+11 | 30524.34 | 06-NOV-07:01 | 17452.47 | 0.00 |
December | 0.00 | 0.00 | 0.156364E+11 | 0.110822E+11 | 30756.43 | 03-DEC-08:61 | 17130.26 | 0.00 |
Annual Sum or Average | 0.204709E+12 | 0.145098E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.135322E+11 | 0.947989E+10 | 30108.21 | 14597.07 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.205825E+11 | 0.145263E+11 | 31359.68 | 18463.22 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.132830E+11 | 0.985924E+10 | 30062.89 | 02-JAN-07:02 | 17313.43 | 0.00 |
February | 0.00 | 0.00 | 0.136866E+11 | 0.928669E+10 | 31075.94 | 18-FEB-07:02 | 14397.20 | 0.00 |
March | 0.00 | 0.00 | 0.146864E+11 | 0.106755E+11 | 30531.91 | 13-MAR-06:02 | 16011.46 | 0.00 |
April | 0.00 | 0.00 | 0.138245E+11 | 0.102769E+11 | 29952.45 | 24-APR-06:02 | 16961.41 | 0.00 |
May | 0.00 | 0.00 | 0.172293E+11 | 0.123717E+11 | 30500.08 | 15-MAY-06:02 | 15791.95 | 0.00 |
June | 0.00 | 0.00 | 0.174647E+11 | 0.123962E+11 | 30087.05 | 18-JUN-07:01 | 18274.89 | 0.00 |
July | 0.00 | 0.00 | 0.196814E+11 | 0.137578E+11 | 31001.55 | 23-JUL-07:01 | 15945.40 | 0.00 |
August | 0.00 | 0.00 | 0.203584E+11 | 0.143372E+11 | 30717.76 | 20-AUG-07:01 | 16527.61 | 0.00 |
September | 0.00 | 0.00 | 0.197809E+11 | 0.134306E+11 | 31202.21 | 25-SEP-06:01 | 14791.41 | 0.00 |
October | 0.00 | 0.00 | 0.196937E+11 | 0.137141E+11 | 30564.19 | 10-OCT-06:01 | 15801.19 | 0.00 |
November | 0.00 | 0.00 | 0.168397E+11 | 0.117820E+11 | 30369.28 | 06-NOV-07:01 | 17294.10 | 0.00 |
December | 0.00 | 0.00 | 0.153942E+11 | 0.108805E+11 | 30594.89 | 03-DEC-08:61 | 16937.64 | 0.00 |
Annual Sum or Average | 0.201923E+12 | 0.142768E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.132830E+11 | 0.928669E+10 | 29952.45 | 14397.20 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.203584E+11 | 0.143372E+11 | 31202.21 | 18274.89 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.228245E+11 | 0.165617E+11 | 54501.61 | 02-JAN-08:62 | 31356.36 | 0.00 |
February | 0.00 | 0.00 | 0.237305E+11 | 0.156806E+11 | 56004.48 | 18-FEB-08:62 | 26456.22 | 0.00 |
March | 0.00 | 0.00 | 0.255719E+11 | 0.181817E+11 | 55253.23 | 13-MAR-07:02 | 28403.18 | 0.00 |
April | 0.00 | 0.00 | 0.239020E+11 | 0.173994E+11 | 54322.63 | 24-APR-07:02 | 30364.52 | 0.00 |
May | 0.00 | 0.00 | 0.302572E+11 | 0.212937E+11 | 55301.24 | 15-MAY-07:02 | 28582.30 | 0.00 |
June | 0.00 | 0.00 | 0.307100E+11 | 0.213502E+11 | 54519.11 | 18-JUN-08:61 | 33304.78 | 0.00 |
July | 0.00 | 0.00 | 0.347469E+11 | 0.238164E+11 | 56255.30 | 23-JUL-08:61 | 29146.12 | 0.00 |
August | 0.00 | 0.00 | 0.361615E+11 | 0.250034E+11 | 55699.58 | 20-AUG-08:61 | 30357.77 | 0.00 |
September | 0.00 | 0.00 | 0.349958E+11 | 0.232962E+11 | 56505.11 | 25-SEP-07:01 | 26406.73 | 0.00 |
October | 0.00 | 0.00 | 0.349323E+11 | 0.238633E+11 | 55380.60 | 10-OCT-07:02 | 28371.78 | 0.00 |
November | 0.00 | 0.00 | 0.294646E+11 | 0.201630E+11 | 55112.37 | 24-NOV-08:61 | 30418.64 | 0.00 |
December | 0.00 | 0.00 | 0.266153E+11 | 0.183751E+11 | 55673.60 | 03-DEC-09:01 | 29955.87 | 0.00 |
Annual Sum or Average | 0.353912E+12 | 0.244985E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.228245E+11 | 0.156806E+11 | 54322.63 | 26406.73 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.361615E+11 | 0.250034E+11 | 56505.11 | 33304.78 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.118004E+11 | 0.856835E+10 | 28335.13 | 02-JAN-08:62 | 16283.18 | 0.00 |
February | 0.00 | 0.00 | 0.122637E+11 | 0.810606E+10 | 29094.74 | 18-FEB-08:62 | 13758.69 | 0.00 |
March | 0.00 | 0.00 | 0.132137E+11 | 0.939829E+10 | 28741.78 | 13-MAR-07:02 | 14713.28 | 0.00 |
April | 0.00 | 0.00 | 0.123517E+11 | 0.899625E+10 | 28247.26 | 24-APR-07:02 | 15748.03 | 0.00 |
May | 0.00 | 0.00 | 0.156511E+11 | 0.110181E+11 | 28766.49 | 15-MAY-07:02 | 14785.52 | 0.00 |
June | 0.00 | 0.00 | 0.158668E+11 | 0.110358E+11 | 28334.10 | 18-JUN-08:61 | 17268.74 | 0.00 |
July | 0.00 | 0.00 | 0.179810E+11 | 0.123290E+11 | 29240.32 | 23-JUL-08:61 | 15074.99 | 0.00 |
August | 0.00 | 0.00 | 0.187140E+11 | 0.129444E+11 | 28954.72 | 20-AUG-08:61 | 15713.36 | 0.00 |
September | 0.00 | 0.00 | 0.181031E+11 | 0.120542E+11 | 29401.44 | 25-SEP-07:01 | 13631.78 | 0.00 |
October | 0.00 | 0.00 | 0.180956E+11 | 0.123656E+11 | 28810.41 | 10-OCT-07:02 | 14699.00 | 0.00 |
November | 0.00 | 0.00 | 0.152405E+11 | 0.104353E+11 | 28654.96 | 24-NOV-08:61 | 15758.56 | 0.00 |
December | 0.00 | 0.00 | 0.137669E+11 | 0.951083E+10 | 28932.69 | 03-DEC-09:01 | 15525.75 | 0.00 |
Annual Sum or Average | 0.183048E+12 | 0.126762E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.118004E+11 | 0.810606E+10 | 28247.26 | 13631.78 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.187140E+11 | 0.129444E+11 | 29401.44 | 17268.74 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.116963E+11 | 0.848106E+10 | 28214.16 | 02-JAN-08:62 | 16180.60 | 0.00 |
February | 0.00 | 0.00 | 0.121616E+11 | 0.802425E+10 | 28973.83 | 18-FEB-08:62 | 13659.44 | 0.00 |
March | 0.00 | 0.00 | 0.131035E+11 | 0.930687E+10 | 28619.15 | 13-MAR-07:02 | 14614.72 | 0.00 |
April | 0.00 | 0.00 | 0.122522E+11 | 0.891236E+10 | 28127.24 | 24-APR-07:02 | 15645.35 | 0.00 |
May | 0.00 | 0.00 | 0.155472E+11 | 0.109308E+11 | 28644.44 | 15-MAY-07:02 | 14687.77 | 0.00 |
June | 0.00 | 0.00 | 0.157656E+11 | 0.109509E+11 | 28213.45 | 18-JUN-08:61 | 17165.21 | 0.00 |
July | 0.00 | 0.00 | 0.178793E+11 | 0.122438E+11 | 29116.56 | 23-JUL-08:61 | 14978.53 | 0.00 |
August | 0.00 | 0.00 | 0.186115E+11 | 0.128580E+11 | 28833.40 | 20-AUG-08:61 | 15620.85 | 0.00 |
September | 0.00 | 0.00 | 0.180013E+11 | 0.119700E+11 | 29277.32 | 25-SEP-07:01 | 13545.04 | 0.00 |
October | 0.00 | 0.00 | 0.179950E+11 | 0.122811E+11 | 28688.32 | 10-OCT-07:02 | 14606.66 | 0.00 |
November | 0.00 | 0.00 | 0.151368E+11 | 0.103497E+11 | 28532.97 | 24-NOV-08:61 | 15656.28 | 0.00 |
December | 0.00 | 0.00 | 0.136623E+11 | 0.942427E+10 | 28810.23 | 03-DEC-09:01 | 15429.44 | 0.00 |
Annual Sum or Average | 0.181813E+12 | 0.125733E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.116963E+11 | 0.802425E+10 | 28127.24 | 13545.04 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.186115E+11 | 0.128580E+11 | 29277.32 | 17165.21 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.115859E+11 | 0.839303E+10 | 28225.11 | 02-JAN-08:62 | 16123.33 | 0.00 |
February | 0.00 | 0.00 | 0.120434E+11 | 0.793414E+10 | 28988.74 | 18-FEB-08:62 | 13590.85 | 0.00 |
March | 0.00 | 0.00 | 0.129862E+11 | 0.921492E+10 | 28633.36 | 13-MAR-07:02 | 14565.92 | 0.00 |
April | 0.00 | 0.00 | 0.121720E+11 | 0.884865E+10 | 28138.67 | 24-APR-07:02 | 15589.52 | 0.00 |
May | 0.00 | 0.00 | 0.155071E+11 | 0.108995E+11 | 28658.00 | 15-MAY-07:02 | 14640.16 | 0.00 |
June | 0.00 | 0.00 | 0.157340E+11 | 0.109267E+11 | 28227.76 | 18-JUN-08:61 | 17132.23 | 0.00 |
July | 0.00 | 0.00 | 0.178689E+11 | 0.122368E+11 | 29134.42 | 23-JUL-08:61 | 14954.69 | 0.00 |
August | 0.00 | 0.00 | 0.186169E+11 | 0.128633E+11 | 28850.78 | 20-AUG-08:61 | 15600.71 | 0.00 |
September | 0.00 | 0.00 | 0.179830E+11 | 0.119568E+11 | 29295.89 | 25-SEP-07:01 | 13521.75 | 0.00 |
October | 0.00 | 0.00 | 0.179772E+11 | 0.122680E+11 | 28705.13 | 10-OCT-07:02 | 14577.90 | 0.00 |
November | 0.00 | 0.00 | 0.150694E+11 | 0.102978E+11 | 28546.06 | 24-NOV-08:61 | 15609.64 | 0.00 |
December | 0.00 | 0.00 | 0.135727E+11 | 0.935386E+10 | 28825.95 | 03-DEC-09:01 | 15396.01 | 0.00 |
Annual Sum or Average | 0.181117E+12 | 0.125194E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.115859E+11 | 0.793414E+10 | 28138.67 | 13521.75 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.186169E+11 | 0.128633E+11 | 29295.89 | 17132.23 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.125285E+11 | 0.920456E+10 | 30847.78 | 03-JAN-08:62 | 16738.13 | 0.00 |
February | 0.00 | 0.00 | 0.127979E+11 | 0.854516E+10 | 31990.84 | 18-FEB-08:62 | 13307.46 | 0.00 |
March | 0.00 | 0.00 | 0.139247E+11 | 0.100120E+11 | 31226.40 | 13-MAR-07:02 | 15521.02 | 0.00 |
April | 0.00 | 0.00 | 0.133841E+11 | 0.987316E+10 | 30595.33 | 24-APR-07:02 | 16915.25 | 0.00 |
May | 0.00 | 0.00 | 0.172213E+11 | 0.123059E+11 | 31259.72 | 10-MAY-07:02 | 15801.77 | 0.00 |
June | 0.00 | 0.00 | 0.174868E+11 | 0.123312E+11 | 30923.68 | 14-JUN-07:02 | 16884.83 | 0.00 |
July | 0.00 | 0.00 | 0.198678E+11 | 0.138300E+11 | 31886.40 | 23-JUL-08:61 | 16557.15 | 0.00 |
August | 0.00 | 0.00 | 0.208048E+11 | 0.146146E+11 | 31579.55 | 20-AUG-08:61 | 17038.64 | 0.00 |
September | 0.00 | 0.00 | 0.197102E+11 | 0.133011E+11 | 31883.27 | 25-SEP-07:01 | 14696.68 | 0.00 |
October | 0.00 | 0.00 | 0.198496E+11 | 0.137807E+11 | 31283.88 | 10-OCT-07:02 | 15690.83 | 0.00 |
November | 0.00 | 0.00 | 0.163820E+11 | 0.113452E+11 | 31226.88 | 01-NOV-07:02 | 16146.39 | 0.00 |
December | 0.00 | 0.00 | 0.146717E+11 | 0.102540E+11 | 31461.78 | 03-DEC-09:01 | 16727.49 | 0.00 |
Annual Sum or Average | 0.198630E+12 | 0.139398E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.125285E+11 | 0.854516E+10 | 30595.33 | 13307.46 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.208048E+11 | 0.146146E+11 | 31990.84 | 17038.64 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.471007E+10 | 0.60 | 2595.94 | 01-JAN-23:50 | 0.89 |
February | 0.426149E+10 | 0.60 | 2595.94 | 03-FEB-08:10 | 0.89 |
March | 0.471941E+10 | 0.60 | 2595.94 | 03-MAR-08:50 | 0.88 |
April | 0.456989E+10 | 0.60 | 2595.94 | 01-APR-22:00 | 0.89 |
May | 0.471007E+10 | 0.60 | 2595.94 | 02-MAY-22:10 | 0.89 |
June | 0.456989E+10 | 0.60 | 2595.94 | 02-JUN-07:50 | 0.88 |
July | 0.471941E+10 | 0.60 | 2595.94 | 01-JUL-07:08 | 0.89 |
August | 0.471007E+10 | 0.60 | 2595.94 | 04-AUG-07:20 | 0.88 |
September | 0.457923E+10 | 0.60 | 2595.94 | 01-SEP-17:00 | 0.89 |
October | 0.471007E+10 | 0.60 | 2595.94 | 02-OCT-15:10 | 0.89 |
November | 0.455120E+10 | 0.60 | 2595.94 | 06-NOV-23:30 | 0.89 |
December | 0.472876E+10 | 0.60 | 2595.94 | 01-DEC-00:40 | 0.89 |
Annual Sum or Average | 0.555396E+11 | 0.60 | |||
Minimum of Months | 0.426149E+10 | 0.60 | 2595.94 | 0.88 | |
Maximum of Months | 0.472876E+10 | 0.60 | 2595.94 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.213008E+10 | 0.66 | 1426.15 | 03-JAN-18:10 | 0.92 |
February | 0.194237E+10 | 0.66 | 1426.15 | 01-FEB-19:30 | 0.92 |
March | 0.216689E+10 | 0.66 | 1426.15 | 01-MAR-20:07 | 0.93 |
April | 0.207594E+10 | 0.67 | 1426.15 | 01-APR-08:20 | 0.93 |
May | 0.217708E+10 | 0.66 | 1426.15 | 02-MAY-08:20 | 0.93 |
June | 0.212279E+10 | 0.66 | 1426.15 | 01-JUN-07:20 | 0.92 |
July | 0.218959E+10 | 0.66 | 1426.15 | 03-JUL-19:23 | 0.93 |
August | 0.221037E+10 | 0.66 | 1426.15 | 04-AUG-07:30 | 0.92 |
September | 0.214245E+10 | 0.66 | 1426.15 | 03-SEP-16:45 | 0.92 |
October | 0.218929E+10 | 0.66 | 1426.15 | 01-OCT-07:20 | 0.92 |
November | 0.209674E+10 | 0.66 | 1426.15 | 01-NOV-08:20 | 0.92 |
December | 0.214645E+10 | 0.67 | 1426.15 | 01-DEC-08:07 | 0.92 |
Annual Sum or Average | 0.255901E+11 | 0.66 | |||
Minimum of Months | 0.194237E+10 | 0.66 | 1426.15 | 0.92 | |
Maximum of Months | 0.221037E+10 | 0.67 | 1426.15 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.205809E+10 | 0.50 | 1422.12 | 01-JAN-08:10 | 0.92 |
February | 0.186354E+10 | 0.50 | 1422.12 | 01-FEB-09:00 | 0.92 |
March | 0.209904E+10 | 0.51 | 1422.12 | 01-MAR-07:30 | 0.92 |
April | 0.199665E+10 | 0.50 | 1422.12 | 01-APR-06:50 | 0.93 |
May | 0.207856E+10 | 0.50 | 1422.12 | 01-MAY-06:10 | 0.92 |
June | 0.202737E+10 | 0.51 | 1422.12 | 01-JUN-06:50 | 0.92 |
July | 0.204785E+10 | 0.50 | 1422.12 | 01-JUL-06:20 | 0.92 |
August | 0.209904E+10 | 0.51 | 1422.12 | 01-AUG-06:10 | 0.92 |
September | 0.199665E+10 | 0.50 | 1422.12 | 01-SEP-06:09 | 0.92 |
October | 0.205809E+10 | 0.50 | 1422.12 | 01-OCT-07:09 | 0.92 |
November | 0.199665E+10 | 0.50 | 1422.12 | 01-NOV-06:30 | 0.92 |
December | 0.204785E+10 | 0.50 | 1422.12 | 01-DEC-07:15 | 0.92 |
Annual Sum or Average | 0.243694E+11 | 0.50 | |||
Minimum of Months | 0.186354E+10 | 0.50 | 1422.12 | 0.92 | |
Maximum of Months | 0.209904E+10 | 0.51 | 1422.12 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.206269E+10 | 0.50 | 1425.29 | 01-JAN-08:10 | 0.92 |
February | 0.186771E+10 | 0.50 | 1425.29 | 01-FEB-08:62 | 0.92 |
March | 0.210373E+10 | 0.51 | 1425.29 | 01-MAR-07:10 | 0.92 |
April | 0.200111E+10 | 0.50 | 1425.29 | 01-APR-07:03 | 0.93 |
May | 0.208321E+10 | 0.50 | 1425.29 | 01-MAY-06:04 | 0.92 |
June | 0.203190E+10 | 0.51 | 1425.29 | 01-JUN-06:50 | 0.92 |
July | 0.205242E+10 | 0.50 | 1425.29 | 01-JUL-06:30 | 0.92 |
August | 0.210373E+10 | 0.51 | 1425.29 | 01-AUG-07:20 | 0.92 |
September | 0.200111E+10 | 0.50 | 1425.29 | 01-SEP-06:04 | 0.92 |
October | 0.206269E+10 | 0.50 | 1425.29 | 01-OCT-07:10 | 0.92 |
November | 0.200111E+10 | 0.50 | 1425.29 | 01-NOV-06:30 | 0.92 |
December | 0.205242E+10 | 0.50 | 1425.29 | 01-DEC-07:08 | 0.92 |
Annual Sum or Average | 0.244238E+11 | 0.50 | |||
Minimum of Months | 0.186771E+10 | 0.50 | 1425.29 | 0.92 | |
Maximum of Months | 0.210373E+10 | 0.51 | 1425.29 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.204985E+10 | 0.50 | 1416.42 | 01-JAN-09:07 | 0.92 |
February | 0.185608E+10 | 0.50 | 1416.42 | 01-FEB-17:30 | 0.92 |
March | 0.209064E+10 | 0.51 | 1416.42 | 01-MAR-15:10 | 0.93 |
April | 0.198866E+10 | 0.50 | 1416.42 | 01-APR-09:10 | 0.93 |
May | 0.207024E+10 | 0.50 | 1416.42 | 02-MAY-11:30 | 0.93 |
June | 0.201925E+10 | 0.51 | 1416.42 | 01-JUN-06:30 | 0.92 |
July | 0.203965E+10 | 0.50 | 1416.42 | 03-JUL-07:50 | 0.92 |
August | 0.209064E+10 | 0.51 | 1416.42 | 01-AUG-06:07 | 0.92 |
September | 0.198866E+10 | 0.50 | 1416.42 | 01-SEP-11:40 | 0.92 |
October | 0.204985E+10 | 0.50 | 1416.42 | 01-OCT-08:15 | 0.92 |
November | 0.198866E+10 | 0.50 | 1416.42 | 01-NOV-08:20 | 0.92 |
December | 0.203965E+10 | 0.50 | 1416.42 | 01-DEC-09:00 | 0.92 |
Annual Sum or Average | 0.242718E+11 | 0.50 | |||
Minimum of Months | 0.185608E+10 | 0.50 | 1416.42 | 0.92 | |
Maximum of Months | 0.209064E+10 | 0.51 | 1416.42 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.322720E+10 | 0.44 | 2416.29 | 26-JAN-20:40 | 0.89 |
February | 0.292274E+10 | 0.44 | 2416.29 | 01-FEB-08:40 | 0.89 |
March | 0.329679E+10 | 0.45 | 2416.29 | 06-MAR-20:12 | 0.89 |
April | 0.313151E+10 | 0.44 | 2416.29 | 01-APR-07:03 | 0.89 |
May | 0.326199E+10 | 0.45 | 2416.29 | 01-MAY-07:04 | 0.89 |
June | 0.318370E+10 | 0.45 | 2416.29 | 14-JUN-07:05 | 0.88 |
July | 0.320980E+10 | 0.44 | 2416.29 | 01-JUL-07:08 | 0.89 |
August | 0.329679E+10 | 0.45 | 2416.29 | 10-AUG-07:10 | 0.88 |
September | 0.313151E+10 | 0.44 | 2416.29 | 09-SEP-07:05 | 0.88 |
October | 0.322720E+10 | 0.44 | 2416.29 | 01-OCT-08:09 | 0.88 |
November | 0.313151E+10 | 0.44 | 2416.29 | 01-NOV-07:08 | 0.88 |
December | 0.320980E+10 | 0.44 | 2416.29 | 01-DEC-08:04 | 0.88 |
Annual Sum or Average | 0.382305E+11 | 0.45 | |||
Minimum of Months | 0.292274E+10 | 0.44 | 2416.29 | 0.88 | |
Maximum of Months | 0.329679E+10 | 0.45 | 2416.29 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.174761E+10 | 0.46 | 1308.49 | 03-JAN-19:20 | 0.92 |
February | 0.158275E+10 | 0.46 | 1308.49 | 01-FEB-20:30 | 0.92 |
March | 0.178530E+10 | 0.47 | 1308.49 | 01-MAR-09:50 | 0.92 |
April | 0.169580E+10 | 0.46 | 1308.49 | 01-APR-07:03 | 0.93 |
May | 0.176646E+10 | 0.47 | 1308.49 | 01-MAY-17:10 | 0.93 |
June | 0.172406E+10 | 0.47 | 1308.49 | 05-JUN-07:07 | 0.92 |
July | 0.173819E+10 | 0.46 | 1308.49 | 01-JUL-07:08 | 0.92 |
August | 0.178530E+10 | 0.47 | 1308.49 | 01-AUG-19:03 | 0.92 |
September | 0.169580E+10 | 0.46 | 1308.49 | 01-SEP-08:50 | 0.92 |
October | 0.174761E+10 | 0.46 | 1308.49 | 01-OCT-08:06 | 0.92 |
November | 0.169580E+10 | 0.46 | 1308.49 | 01-NOV-19:05 | 0.92 |
December | 0.173819E+10 | 0.46 | 1308.49 | 04-DEC-20:05 | 0.93 |
Annual Sum or Average | 0.207029E+11 | 0.46 | |||
Minimum of Months | 0.158275E+10 | 0.46 | 1308.49 | 0.92 | |
Maximum of Months | 0.178530E+10 | 0.47 | 1308.49 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.173804E+10 | 0.46 | 1301.32 | 01-JAN-09:10 | 0.92 |
February | 0.157408E+10 | 0.46 | 1301.32 | 01-FEB-08:50 | 0.92 |
March | 0.177552E+10 | 0.47 | 1301.32 | 01-MAR-10:10 | 0.92 |
April | 0.168651E+10 | 0.46 | 1301.32 | 01-APR-07:40 | 0.93 |
May | 0.175678E+10 | 0.47 | 1301.32 | 01-MAY-07:08 | 0.92 |
June | 0.171462E+10 | 0.47 | 1301.32 | 01-JUN-07:30 | 0.92 |
July | 0.172868E+10 | 0.46 | 1301.32 | 01-JUL-08:20 | 0.92 |
August | 0.177552E+10 | 0.47 | 1301.32 | 01-AUG-07:08 | 0.92 |
September | 0.168651E+10 | 0.46 | 1301.32 | 01-SEP-07:10 | 0.92 |
October | 0.173804E+10 | 0.46 | 1301.32 | 01-OCT-08:07 | 0.92 |
November | 0.168651E+10 | 0.46 | 1301.32 | 01-NOV-07:30 | 0.92 |
December | 0.172868E+10 | 0.46 | 1301.32 | 01-DEC-08:04 | 0.92 |
Annual Sum or Average | 0.205895E+11 | 0.46 | |||
Minimum of Months | 0.157408E+10 | 0.46 | 1301.32 | 0.92 | |
Maximum of Months | 0.177552E+10 | 0.47 | 1301.32 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.173987E+10 | 0.46 | 1302.69 | 03-JAN-09:00 | 0.92 |
February | 0.157573E+10 | 0.46 | 1302.69 | 04-FEB-10:20 | 0.92 |
March | 0.177739E+10 | 0.47 | 1302.69 | 01-MAR-08:20 | 0.92 |
April | 0.168828E+10 | 0.46 | 1302.69 | 01-APR-08:20 | 0.93 |
May | 0.175863E+10 | 0.47 | 1302.69 | 02-MAY-17:20 | 0.93 |
June | 0.171642E+10 | 0.47 | 1302.69 | 02-JUN-07:08 | 0.92 |
July | 0.173049E+10 | 0.46 | 1302.69 | 02-JUL-08:09 | 0.92 |
August | 0.177739E+10 | 0.47 | 1302.69 | 02-AUG-08:50 | 0.92 |
September | 0.168828E+10 | 0.46 | 1302.69 | 02-SEP-14:40 | 0.92 |
October | 0.173987E+10 | 0.46 | 1302.69 | 02-OCT-08:30 | 0.92 |
November | 0.168828E+10 | 0.46 | 1302.69 | 01-NOV-18:30 | 0.92 |
December | 0.173049E+10 | 0.46 | 1302.69 | 01-DEC-10:50 | 0.92 |
Annual Sum or Average | 0.206111E+11 | 0.46 | |||
Minimum of Months | 0.157573E+10 | 0.46 | 1302.69 | 0.92 | |
Maximum of Months | 0.177739E+10 | 0.47 | 1302.69 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.194589E+10 | 0.46 | 1456.94 | 02-JAN-20:23 | 0.92 |
February | 0.176232E+10 | 0.46 | 1456.94 | 01-FEB-08:07 | 0.92 |
March | 0.198785E+10 | 0.47 | 1456.94 | 01-MAR-09:00 | 0.92 |
April | 0.188820E+10 | 0.46 | 1456.94 | 01-APR-07:03 | 0.93 |
May | 0.196687E+10 | 0.47 | 1456.94 | 01-MAY-10:40 | 0.93 |
June | 0.191967E+10 | 0.47 | 1456.94 | 01-JUN-19:15 | 0.92 |
July | 0.193540E+10 | 0.46 | 1456.94 | 03-JUL-07:15 | 0.92 |
August | 0.198785E+10 | 0.47 | 1456.94 | 01-AUG-12:30 | 0.92 |
September | 0.188820E+10 | 0.46 | 1456.94 | 01-SEP-14:10 | 0.92 |
October | 0.194589E+10 | 0.46 | 1456.94 | 01-OCT-14:40 | 0.92 |
November | 0.188820E+10 | 0.46 | 1456.94 | 01-NOV-07:07 | 0.92 |
December | 0.193540E+10 | 0.46 | 1456.94 | 01-DEC-09:40 | 0.92 |
Annual Sum or Average | 0.230517E+11 | 0.46 | |||
Minimum of Months | 0.176232E+10 | 0.46 | 1456.94 | 0.92 | |
Maximum of Months | 0.198785E+10 | 0.47 | 1456.94 | 0.93 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.19 | 0.64 |
February | 0.28 | 0.00 |
March | 0.17 | 0.00 |
April | 0.33 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 1.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.17 | 0.00 |
Annual Sum or Average | 2.14 | 0.06 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.00 | 0.64 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.11 | 0.00 |
February | 0.69 | 0.00 |
March | 0.25 | 0.00 |
April | 0.67 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.33 | 0.00 |
Annual Sum or Average | 2.06 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.69 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.64 | 0.75 |
February | 2.30 | 0.75 |
March | 2.75 | 0.68 |
April | 2.91 | 0.75 |
May | 3.37 | 0.75 |
June | 4.00 | 0.75 |
July | 5.32 | 0.75 |
August | 5.37 | 0.73 |
September | 5.08 | 0.68 |
October | 4.47 | 0.75 |
November | 3.37 | 0.75 |
December | 2.64 | 0.75 |
Annual Sum or Average | 44.23 | 0.73 |
Minimum of Months | 2.30 | 0.68 |
Maximum of Months | 5.37 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.64 | 0.75 |
February | 2.22 | 0.75 |
March | 2.75 | 0.68 |
April | 2.91 | 0.75 |
May | 3.37 | 0.75 |
June | 4.00 | 0.75 |
July | 5.32 | 0.75 |
August | 5.37 | 0.73 |
September | 5.08 | 0.68 |
October | 4.47 | 0.75 |
November | 3.37 | 0.75 |
December | 2.64 | 0.75 |
Annual Sum or Average | 44.15 | 0.73 |
Minimum of Months | 2.22 | 0.68 |
Maximum of Months | 5.37 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.51 | 0.75 |
February | 2.22 | 0.75 |
March | 2.58 | 0.73 |
April | 2.91 | 0.75 |
May | 3.31 | 0.75 |
June | 4.00 | 0.75 |
July | 5.32 | 0.75 |
August | 5.46 | 0.73 |
September | 5.08 | 0.68 |
October | 4.47 | 0.75 |
November | 3.37 | 0.75 |
December | 2.64 | 0.75 |
Annual Sum or Average | 43.87 | 0.74 |
Minimum of Months | 2.22 | 0.68 |
Maximum of Months | 5.46 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.74 | 2.68 |
February | 0.87 | 2.25 |
March | 1.15 | 2.10 |
April | 1.44 | 2.34 |
May | 2.12 | 2.00 |
June | 2.01 | 1.93 |
July | 2.16 | 3.05 |
August | 1.78 | 2.68 |
September | 2.30 | 2.11 |
October | 1.64 | 2.85 |
November | 2.03 | 1.94 |
December | 1.76 | 1.21 |
Annual Sum or Average | 20.00 | 2.24 |
Minimum of Months | 0.74 | 1.21 |
Maximum of Months | 2.30 | 3.05 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.74 | 1.34 |
February | 0.79 | 1.24 |
March | 1.15 | 1.05 |
April | 1.38 | 1.15 |
May | 2.12 | 1.00 |
June | 1.93 | 1.01 |
July | 1.99 | 1.65 |
August | 1.53 | 1.47 |
September | 1.72 | 1.33 |
October | 1.56 | 1.41 |
November | 2.03 | 0.97 |
December | 1.67 | 0.64 |
Annual Sum or Average | 18.61 | 1.18 |
Minimum of Months | 0.74 | 0.64 |
Maximum of Months | 2.12 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.74 | 1.34 |
February | 0.79 | 1.24 |
March | 1.07 | 1.13 |
April | 1.30 | 1.23 |
May | 1.95 | 1.09 |
June | 1.76 | 1.10 |
July | 1.99 | 1.65 |
August | 1.53 | 1.47 |
September | 1.72 | 1.33 |
October | 1.56 | 1.41 |
November | 1.86 | 1.06 |
December | 1.42 | 0.75 |
Annual Sum or Average | 17.69 | 1.24 |
Minimum of Months | 0.74 | 0.75 |
Maximum of Months | 1.99 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.74 | 1.34 |
February | 0.79 | 1.24 |
March | 0.98 | 1.23 |
April | 1.22 | 1.31 |
May | 1.87 | 1.13 |
June | 1.59 | 1.22 |
July | 1.99 | 1.65 |
August | 1.53 | 1.47 |
September | 1.72 | 1.33 |
October | 1.48 | 1.49 |
November | 1.78 | 1.11 |
December | 1.34 | 0.79 |
Annual Sum or Average | 17.03 | 1.29 |
Minimum of Months | 0.74 | 0.79 |
Maximum of Months | 1.99 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.71 | 1.52 |
February | 0.79 | 1.24 |
March | 1.12 | 1.16 |
April | 1.49 | 1.19 |
May | 2.09 | 1.06 |
June | 1.93 | 1.01 |
July | 1.99 | 1.65 |
August | 1.53 | 1.47 |
September | 1.80 | 1.19 |
October | 1.48 | 1.49 |
November | 1.78 | 1.11 |
December | 1.59 | 0.67 |
Annual Sum or Average | 18.30 | 1.21 |
Minimum of Months | 0.71 | 0.67 |
Maximum of Months | 2.09 | 1.65 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.145225E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.143023E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.155992E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.150669E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.175983E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.175795E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.196575E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.199188E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.195421E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.194169E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.169255E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.161227E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.206252E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.143023E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.199188E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.700198E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.684167E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.748136E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.717796E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.836486E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.832171E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.925439E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.940529E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.916882E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.920430E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.805216E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.769389E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.979684E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.684167E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.940529E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.592152E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.577010E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.636953E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.605182E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.710765E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.709608E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.775811E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.804861E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.765280E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.775763E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.684432E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.647232E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.828505E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.577010E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.804861E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.592143E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.577277E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.637593E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.605692E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.712106E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.711005E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.777908E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.806854E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.767675E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.777861E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.685318E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.647689E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.829912E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.577277E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.806854E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.584227E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.569817E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.629251E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.597857E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.704496E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.703717E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.770981E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.799455E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.760892E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.770557E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.678095E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.640016E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.820936E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.569817E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.799455E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.101540E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.999257E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.110702E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.104623E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.125324E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.125395E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.138099E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.144092E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.136603E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.138586E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.120225E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.112132E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.145725E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.999257E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.144092E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.512613E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.502955E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.557469E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.526995E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.629064E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.628535E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.691345E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.721089E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.683450E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.694246E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.603479E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.564403E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.731564E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.502955E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.721089E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.508798E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.499308E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.553441E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.523300E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.625173E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.624765E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.687502E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.717157E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.679657E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.690429E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.599675E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.560586E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.726979E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.499308E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.717157E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.506121E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.496446E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.550574E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.521401E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.624367E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.624209E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.687503E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.717550E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.679429E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.690201E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.598194E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.558508E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.725450E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.496446E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.717550E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.554279E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.537530E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.599390E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.576490E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.694240E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.694242E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.764832E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.800842E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.748748E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.764347E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.656158E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.610948E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.800205E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.537530E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.800842E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.471007E+10 | 0.324611E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.426149E+10 | 0.337832E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.471941E+10 | 0.359792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.456989E+10 | 0.344289E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.471007E+10 | 0.422413E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.456989E+10 | 0.427808E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.471941E+10 | 0.490270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.471007E+10 | 0.496584E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.457923E+10 | 0.497109E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471007E+10 | 0.483728E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.455120E+10 | 0.410804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.472876E+10 | 0.379478E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.555396E+11 | 0.497472E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.426149E+10 | 0.324611E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.472876E+10 | 0.497109E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.213008E+10 | 0.168845E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.194237E+10 | 0.172284E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.216689E+10 | 0.183797E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207594E+10 | 0.174901E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217708E+10 | 0.211681E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.212279E+10 | 0.212662E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.218959E+10 | 0.241287E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.221037E+10 | 0.244662E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.214245E+10 | 0.242556E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.218929E+10 | 0.240474E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.209674E+10 | 0.206452E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.214645E+10 | 0.193106E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.255901E+11 | 0.249271E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.194237E+10 | 0.168845E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.221037E+10 | 0.244662E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.205809E+10 | 0.135531E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.186354E+10 | 0.139345E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.209904E+10 | 0.149464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.199665E+10 | 0.140703E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207856E+10 | 0.174350E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.202737E+10 | 0.176565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.204785E+10 | 0.198308E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.209904E+10 | 0.205285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.199665E+10 | 0.199159E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.205809E+10 | 0.198580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.199665E+10 | 0.170522E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.204785E+10 | 0.156399E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.243694E+11 | 0.204421E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.186354E+10 | 0.135531E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.209904E+10 | 0.205285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.206269E+10 | 0.135322E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.186771E+10 | 0.139255E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.210373E+10 | 0.149493E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.200111E+10 | 0.140695E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.208321E+10 | 0.174640E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.203190E+10 | 0.176892E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.205242E+10 | 0.198899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.210373E+10 | 0.205825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.200111E+10 | 0.199879E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.206269E+10 | 0.199171E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.200111E+10 | 0.170653E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.205242E+10 | 0.156364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.244238E+11 | 0.204709E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.186771E+10 | 0.135322E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.210373E+10 | 0.205825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.204985E+10 | 0.132830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.185608E+10 | 0.136866E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.209064E+10 | 0.146864E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.198866E+10 | 0.138245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207024E+10 | 0.172293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.201925E+10 | 0.174647E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.203965E+10 | 0.196814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.209064E+10 | 0.203584E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.198866E+10 | 0.197809E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.204985E+10 | 0.196937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198866E+10 | 0.168397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.203965E+10 | 0.153942E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.242718E+11 | 0.201923E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.185608E+10 | 0.132830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.209064E+10 | 0.203584E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.322720E+10 | 0.228245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.292274E+10 | 0.237305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.329679E+10 | 0.255719E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.313151E+10 | 0.239020E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.326199E+10 | 0.302572E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.318370E+10 | 0.307100E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.320980E+10 | 0.347469E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.329679E+10 | 0.361615E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.313151E+10 | 0.349958E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.322720E+10 | 0.349323E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.313151E+10 | 0.294646E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.320980E+10 | 0.266153E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.382305E+11 | 0.353912E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.292274E+10 | 0.228245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.329679E+10 | 0.361615E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.174761E+10 | 0.118004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.158275E+10 | 0.122637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.178530E+10 | 0.132137E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.169580E+10 | 0.123517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.176646E+10 | 0.156511E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.172406E+10 | 0.158668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.173819E+10 | 0.179810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.178530E+10 | 0.187140E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.169580E+10 | 0.181031E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174761E+10 | 0.180956E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.169580E+10 | 0.152405E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.173819E+10 | 0.137669E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.207029E+11 | 0.183048E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.158275E+10 | 0.118004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.178530E+10 | 0.187140E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.173804E+10 | 0.116963E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.157408E+10 | 0.121616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.177552E+10 | 0.131035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.168651E+10 | 0.122522E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.175678E+10 | 0.155472E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.171462E+10 | 0.157656E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.172868E+10 | 0.178793E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.177552E+10 | 0.186115E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.168651E+10 | 0.180013E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.173804E+10 | 0.179950E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168651E+10 | 0.151368E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.172868E+10 | 0.136623E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.205895E+11 | 0.181813E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.157408E+10 | 0.116963E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.177552E+10 | 0.186115E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.173987E+10 | 0.115859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.157573E+10 | 0.120434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.177739E+10 | 0.129862E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.168828E+10 | 0.121720E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.175863E+10 | 0.155071E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.171642E+10 | 0.157340E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.173049E+10 | 0.178689E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.177739E+10 | 0.186169E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.168828E+10 | 0.179830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.173987E+10 | 0.179772E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168828E+10 | 0.150694E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.173049E+10 | 0.135727E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.206111E+11 | 0.181117E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.157573E+10 | 0.115859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.177739E+10 | 0.186169E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.194589E+10 | 0.125285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176232E+10 | 0.127979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.198785E+10 | 0.139247E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.188820E+10 | 0.133841E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196687E+10 | 0.172213E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.191967E+10 | 0.174868E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.193540E+10 | 0.198678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.198785E+10 | 0.208048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.188820E+10 | 0.197102E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194589E+10 | 0.198496E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.188820E+10 | 0.163820E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.193540E+10 | 0.146717E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230517E+11 | 0.198630E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.176232E+10 | 0.125285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.198785E+10 | 0.208048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.471007E+10 | 0.00 | 0.00 | 0.00 | 0.981244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.426149E+10 | 0.00 | 0.00 | 0.00 | 0.100408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.471941E+10 | 0.00 | 0.00 | 0.00 | 0.108797E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.456989E+10 | 0.00 | 0.00 | 0.00 | 0.104970E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.471007E+10 | 0.00 | 0.00 | 0.00 | 0.128882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.456989E+10 | 0.00 | 0.00 | 0.00 | 0.130096E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.471941E+10 | 0.00 | 0.00 | 0.00 | 0.149381E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.471007E+10 | 0.00 | 0.00 | 0.00 | 0.152088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.457923E+10 | 0.00 | 0.00 | 0.00 | 0.149629E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471007E+10 | 0.00 | 0.00 | 0.00 | 0.147069E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.455120E+10 | 0.00 | 0.00 | 0.00 | 0.123743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.472876E+10 | 0.00 | 0.00 | 0.00 | 0.113939E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.555396E+11 | 0.00 | 0.00 | 0.00 | 0.150713E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.426149E+10 | 0.00 | 0.00 | 0.00 | 0.981244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.472876E+10 | 0.00 | 0.00 | 0.00 | 0.152088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.213008E+10 | 0.00 | 0.00 | 0.00 | 0.487191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.194237E+10 | 0.00 | 0.00 | 0.00 | 0.489930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.216689E+10 | 0.00 | 0.00 | 0.00 | 0.531447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.207594E+10 | 0.00 | 0.00 | 0.00 | 0.510202E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217708E+10 | 0.00 | 0.00 | 0.00 | 0.618778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.212279E+10 | 0.00 | 0.00 | 0.00 | 0.619892E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.218959E+10 | 0.00 | 0.00 | 0.00 | 0.706480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.221037E+10 | 0.00 | 0.00 | 0.00 | 0.719491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.214245E+10 | 0.00 | 0.00 | 0.00 | 0.702637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.218929E+10 | 0.00 | 0.00 | 0.00 | 0.701501E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.209674E+10 | 0.00 | 0.00 | 0.00 | 0.595542E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.214645E+10 | 0.00 | 0.00 | 0.00 | 0.554744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.255901E+11 | 0.00 | 0.00 | 0.00 | 0.723783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.194237E+10 | 0.00 | 0.00 | 0.00 | 0.487191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.221037E+10 | 0.00 | 0.00 | 0.00 | 0.719491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.205809E+10 | 0.00 | 0.00 | 0.00 | 0.386344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.186354E+10 | 0.00 | 0.00 | 0.00 | 0.390656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.209904E+10 | 0.00 | 0.00 | 0.00 | 0.427049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.199665E+10 | 0.00 | 0.00 | 0.00 | 0.405516E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207856E+10 | 0.00 | 0.00 | 0.00 | 0.502909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.202737E+10 | 0.00 | 0.00 | 0.00 | 0.506871E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.204785E+10 | 0.00 | 0.00 | 0.00 | 0.571026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.209904E+10 | 0.00 | 0.00 | 0.00 | 0.594957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.199665E+10 | 0.00 | 0.00 | 0.00 | 0.565615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.205809E+10 | 0.00 | 0.00 | 0.00 | 0.569954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.199665E+10 | 0.00 | 0.00 | 0.00 | 0.484767E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.204785E+10 | 0.00 | 0.00 | 0.00 | 0.442448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.243694E+11 | 0.00 | 0.00 | 0.00 | 0.584811E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.186354E+10 | 0.00 | 0.00 | 0.00 | 0.386344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.209904E+10 | 0.00 | 0.00 | 0.00 | 0.594957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.206269E+10 | 0.00 | 0.00 | 0.00 | 0.385875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.186771E+10 | 0.00 | 0.00 | 0.00 | 0.390507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.210373E+10 | 0.00 | 0.00 | 0.00 | 0.427219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.200111E+10 | 0.00 | 0.00 | 0.00 | 0.405581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.208321E+10 | 0.00 | 0.00 | 0.00 | 0.503785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.203190E+10 | 0.00 | 0.00 | 0.00 | 0.507815E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.205242E+10 | 0.00 | 0.00 | 0.00 | 0.572666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.210373E+10 | 0.00 | 0.00 | 0.00 | 0.596480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.200111E+10 | 0.00 | 0.00 | 0.00 | 0.567564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.206269E+10 | 0.00 | 0.00 | 0.00 | 0.571592E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.200111E+10 | 0.00 | 0.00 | 0.00 | 0.485206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.205242E+10 | 0.00 | 0.00 | 0.00 | 0.442447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.244238E+11 | 0.00 | 0.00 | 0.00 | 0.585674E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.186771E+10 | 0.00 | 0.00 | 0.00 | 0.385875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.210373E+10 | 0.00 | 0.00 | 0.00 | 0.596480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.204985E+10 | 0.00 | 0.00 | 0.00 | 0.379243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.185608E+10 | 0.00 | 0.00 | 0.00 | 0.384209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.209064E+10 | 0.00 | 0.00 | 0.00 | 0.420187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.198866E+10 | 0.00 | 0.00 | 0.00 | 0.398991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207024E+10 | 0.00 | 0.00 | 0.00 | 0.497472E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.201925E+10 | 0.00 | 0.00 | 0.00 | 0.501791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.203965E+10 | 0.00 | 0.00 | 0.00 | 0.567016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.209064E+10 | 0.00 | 0.00 | 0.00 | 0.590391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.198866E+10 | 0.00 | 0.00 | 0.00 | 0.562027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.204985E+10 | 0.00 | 0.00 | 0.00 | 0.565572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198866E+10 | 0.00 | 0.00 | 0.00 | 0.479229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.203965E+10 | 0.00 | 0.00 | 0.00 | 0.436051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.242718E+11 | 0.00 | 0.00 | 0.00 | 0.578218E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.185608E+10 | 0.00 | 0.00 | 0.00 | 0.379243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.209064E+10 | 0.00 | 0.00 | 0.00 | 0.590391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.322720E+10 | 0.00 | 0.00 | 0.00 | 0.692677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.292274E+10 | 0.00 | 0.00 | 0.00 | 0.706982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.329679E+10 | 0.00 | 0.00 | 0.00 | 0.777344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.313151E+10 | 0.00 | 0.00 | 0.00 | 0.733083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.326199E+10 | 0.00 | 0.00 | 0.00 | 0.927039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.318370E+10 | 0.00 | 0.00 | 0.00 | 0.935582E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.320980E+10 | 0.00 | 0.00 | 0.00 | 0.106001E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.329679E+10 | 0.00 | 0.00 | 0.00 | 0.111124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.313151E+10 | 0.00 | 0.00 | 0.00 | 0.105288E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.322720E+10 | 0.00 | 0.00 | 0.00 | 0.106314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.313151E+10 | 0.00 | 0.00 | 0.00 | 0.889097E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.320980E+10 | 0.00 | 0.00 | 0.00 | 0.800345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.382305E+11 | 0.00 | 0.00 | 0.00 | 0.107494E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.292274E+10 | 0.00 | 0.00 | 0.00 | 0.692677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.329679E+10 | 0.00 | 0.00 | 0.00 | 0.111124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.174761E+10 | 0.00 | 0.00 | 0.00 | 0.337851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.158275E+10 | 0.00 | 0.00 | 0.00 | 0.344680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.178530E+10 | 0.00 | 0.00 | 0.00 | 0.378939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.169580E+10 | 0.00 | 0.00 | 0.00 | 0.357416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.176646E+10 | 0.00 | 0.00 | 0.00 | 0.452418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.172406E+10 | 0.00 | 0.00 | 0.00 | 0.456129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.173819E+10 | 0.00 | 0.00 | 0.00 | 0.517526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.178530E+10 | 0.00 | 0.00 | 0.00 | 0.542559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.169580E+10 | 0.00 | 0.00 | 0.00 | 0.513870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174761E+10 | 0.00 | 0.00 | 0.00 | 0.519485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.169580E+10 | 0.00 | 0.00 | 0.00 | 0.433899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.173819E+10 | 0.00 | 0.00 | 0.00 | 0.390584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.207029E+11 | 0.00 | 0.00 | 0.00 | 0.524536E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.158275E+10 | 0.00 | 0.00 | 0.00 | 0.337851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.178530E+10 | 0.00 | 0.00 | 0.00 | 0.542559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.173804E+10 | 0.00 | 0.00 | 0.00 | 0.334993E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.157408E+10 | 0.00 | 0.00 | 0.00 | 0.341900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.177552E+10 | 0.00 | 0.00 | 0.00 | 0.375889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.168651E+10 | 0.00 | 0.00 | 0.00 | 0.354649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.175678E+10 | 0.00 | 0.00 | 0.00 | 0.449495E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.171462E+10 | 0.00 | 0.00 | 0.00 | 0.453303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.172868E+10 | 0.00 | 0.00 | 0.00 | 0.514635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.177552E+10 | 0.00 | 0.00 | 0.00 | 0.539605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.168651E+10 | 0.00 | 0.00 | 0.00 | 0.511006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.173804E+10 | 0.00 | 0.00 | 0.00 | 0.516625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168651E+10 | 0.00 | 0.00 | 0.00 | 0.431024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.172868E+10 | 0.00 | 0.00 | 0.00 | 0.387718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.205895E+11 | 0.00 | 0.00 | 0.00 | 0.521084E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.157408E+10 | 0.00 | 0.00 | 0.00 | 0.334993E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.177552E+10 | 0.00 | 0.00 | 0.00 | 0.539605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.173987E+10 | 0.00 | 0.00 | 0.00 | 0.332134E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.157573E+10 | 0.00 | 0.00 | 0.00 | 0.338873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.177739E+10 | 0.00 | 0.00 | 0.00 | 0.372835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.168828E+10 | 0.00 | 0.00 | 0.00 | 0.352572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.175863E+10 | 0.00 | 0.00 | 0.00 | 0.448504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.171642E+10 | 0.00 | 0.00 | 0.00 | 0.452567E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.173049E+10 | 0.00 | 0.00 | 0.00 | 0.514454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.177739E+10 | 0.00 | 0.00 | 0.00 | 0.539811E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.168828E+10 | 0.00 | 0.00 | 0.00 | 0.510600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.173987E+10 | 0.00 | 0.00 | 0.00 | 0.516214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168828E+10 | 0.00 | 0.00 | 0.00 | 0.429365E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.173049E+10 | 0.00 | 0.00 | 0.00 | 0.385459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.206111E+11 | 0.00 | 0.00 | 0.00 | 0.519339E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.157573E+10 | 0.00 | 0.00 | 0.00 | 0.332134E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.177739E+10 | 0.00 | 0.00 | 0.00 | 0.539811E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.194589E+10 | 0.00 | 0.00 | 0.00 | 0.359690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176232E+10 | 0.00 | 0.00 | 0.00 | 0.361298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.198785E+10 | 0.00 | 0.00 | 0.00 | 0.400605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.188820E+10 | 0.00 | 0.00 | 0.00 | 0.387670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196687E+10 | 0.00 | 0.00 | 0.00 | 0.497553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.191967E+10 | 0.00 | 0.00 | 0.00 | 0.502276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.193540E+10 | 0.00 | 0.00 | 0.00 | 0.571292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.198785E+10 | 0.00 | 0.00 | 0.00 | 0.602057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.188820E+10 | 0.00 | 0.00 | 0.00 | 0.559928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194589E+10 | 0.00 | 0.00 | 0.00 | 0.569757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.188820E+10 | 0.00 | 0.00 | 0.00 | 0.467339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.193540E+10 | 0.00 | 0.00 | 0.00 | 0.417408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230517E+11 | 0.00 | 0.00 | 0.00 | 0.569687E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.176232E+10 | 0.00 | 0.00 | 0.00 | 0.359690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.198785E+10 | 0.00 | 0.00 | 0.00 | 0.602057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 12614798.54 | 0.515685E+10 | 0.00 | 3562687.70 | 25986087.06 | 0.00 | 0.107447E+09 | 0.00 | 0.57 |
February | 7497497.64 | 0.744080E+10 | 0.00 | 2027339.56 | 49344326.51 | 0.00 | 0.111121E+09 | 0.00 | 0.57 |
March | 14373945.34 | 0.695963E+10 | 0.00 | 1550010.73 | 28494901.54 | 0.00 | 59473609.25 | 0.00 | 0.57 |
April | 5810820.59 | 0.660108E+10 | 0.00 | 595800.93 | 36032879.08 | 0.00 | 8507869.40 | 0.00 | 0.57 |
May | 0.00 | 0.102728E+11 | 0.00 | 172878.04 | 66053194.07 | 0.00 | 53749.40 | 0.00 | 0.57 |
June | 0.00 | 0.105333E+11 | 0.00 | 38694.30 | 53696019.62 | 0.00 | 0.00 | 0.00 | 0.57 |
July | 411153.81 | 0.132929E+11 | 0.00 | 440068.03 | 43928360.96 | 0.00 | 1239664.24 | 0.00 | 0.57 |
August | 0.00 | 0.137957E+11 | 0.00 | 0.00 | 51371768.38 | 0.00 | 0.00 | 0.00 | 0.57 |
September | 0.00 | 0.140540E+11 | 0.00 | 0.00 | 56070522.10 | 0.00 | 0.00 | 0.00 | 0.57 |
October | 0.00 | 0.134222E+11 | 0.00 | 174261.15 | 61361228.26 | 0.00 | 117535.00 | 0.00 | 0.57 |
November | 66803.24 | 0.972149E+10 | 0.00 | 192839.36 | 50541021.87 | 0.00 | 150409.18 | 0.00 | 0.57 |
December | 1894279.47 | 0.799435E+10 | 0.00 | 1242356.10 | 41146232.76 | 0.00 | 7862065.25 | 0.00 | 0.57 |
Annual Sum or Average | 42669298.62 | 0.119245E+12 | 0.00 | 9996935.92 | 0.564027E+09 | 0.00 | 0.295973E+09 | 0.00 | 0.57 |
Minimum of Months | 0.00 | 0.515685E+10 | 0.00 | 0.00 | 25986087.06 | 0.00 | 0.00 | 0.00 | 0.57 |
Maximum of Months | 14373945.34 | 0.140540E+11 | 0.00 | 3562687.70 | 66053194.07 | 0.00 | 0.111121E+09 | 0.00 | 0.57 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2939150.50 | 0.243707E+10 | 0.00 | 1308837.60 | 27265374.33 | 0.00 | 21892423.66 | 0.00 | 0.46 |
February | 2256892.42 | 0.336647E+10 | 0.00 | 937159.04 | 43012463.97 | 0.00 | 15686205.45 | 0.00 | 0.47 |
March | 2253717.32 | 0.318370E+10 | 0.00 | 431275.59 | 31088567.17 | 0.00 | 7239202.28 | 0.00 | 0.47 |
April | 1315563.16 | 0.297683E+10 | 0.00 | 169729.24 | 35472019.45 | 0.00 | 1845793.67 | 0.00 | 0.46 |
May | 0.00 | 0.455203E+10 | 0.00 | 0.00 | 44524770.15 | 0.00 | 0.00 | 0.00 | 0.47 |
June | 0.00 | 0.463698E+10 | 0.00 | 0.00 | 30506294.52 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.577946E+10 | 0.00 | 82071.71 | 28202321.84 | 0.00 | 0.00 | 0.00 | 0.47 |
August | 0.00 | 0.605955E+10 | 0.00 | 0.00 | 34961423.23 | 0.00 | 0.00 | 0.00 | 0.48 |
September | 0.00 | 0.604437E+10 | 0.00 | 0.00 | 41058418.83 | 0.00 | 0.00 | 0.00 | 0.48 |
October | 0.00 | 0.589941E+10 | 0.00 | 0.00 | 38477478.76 | 0.00 | 0.00 | 0.00 | 0.47 |
November | 0.00 | 0.435206E+10 | 0.00 | 0.00 | 30586316.62 | 0.00 | 0.00 | 0.00 | 0.47 |
December | 128148.86 | 0.358861E+10 | 0.00 | 256503.14 | 35021987.56 | 0.00 | 651954.11 | 0.00 | 0.46 |
Annual Sum or Average | 8893472.26 | 0.528765E+11 | 0.00 | 3185576.31 | 0.420177E+09 | 0.00 | 47315579.17 | 0.00 | 0.47 |
Minimum of Months | 0.00 | 0.243707E+10 | 0.00 | 0.00 | 27265374.33 | 0.00 | 0.00 | 0.00 | 0.46 |
Maximum of Months | 2939150.50 | 0.605955E+10 | 0.00 | 1308837.60 | 44524770.15 | 0.00 | 21892423.66 | 0.00 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 39577171.02 | 0.211397E+10 | 0.00 | 1400040.80 | 61258711.12 | 0.00 | 49932168.02 | 0.00 | 0.45 |
February | 23870452.12 | 0.286368E+10 | 0.00 | 946351.49 | 0.127664E+09 | 0.00 | 34679332.14 | 0.00 | 0.46 |
March | 24139424.46 | 0.274717E+10 | 0.00 | 963299.14 | 0.104955E+09 | 0.00 | 44888305.16 | 0.00 | 0.46 |
April | 12739009.02 | 0.256362E+10 | 0.00 | 798490.03 | 98916059.95 | 0.00 | 17637488.84 | 0.00 | 0.46 |
May | 1065277.89 | 0.391803E+10 | 0.00 | 785901.59 | 0.198096E+09 | 0.00 | 1818876.53 | 0.00 | 0.46 |
June | 0.00 | 0.406008E+10 | 0.00 | 185133.52 | 0.215367E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.494654E+10 | 0.00 | 328984.42 | 0.280004E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
August | 0.00 | 0.522729E+10 | 0.00 | 419353.55 | 0.299614E+09 | 0.00 | 25527.74 | 0.00 | 0.46 |
September | 0.00 | 0.505221E+10 | 0.00 | 519519.77 | 0.300747E+09 | 0.00 | 170958.28 | 0.00 | 0.46 |
October | 589491.17 | 0.495136E+10 | 0.00 | 947930.87 | 0.272638E+09 | 0.00 | 1900838.46 | 0.00 | 0.46 |
November | 3558220.26 | 0.379287E+10 | 0.00 | 649106.83 | 0.167809E+09 | 0.00 | 3166200.97 | 0.00 | 0.46 |
December | 8815336.13 | 0.308761E+10 | 0.00 | 961162.13 | 0.125862E+09 | 0.00 | 9279172.41 | 0.00 | 0.45 |
Annual Sum or Average | 0.114354E+09 | 0.453244E+11 | 0.00 | 8905274.15 | 0.225293E+10 | 0.00 | 0.163499E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.211397E+10 | 0.00 | 185133.52 | 61258711.12 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 39577171.02 | 0.522729E+10 | 0.00 | 1400040.80 | 0.300747E+09 | 0.00 | 49932168.02 | 0.00 | 0.46 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 39680912.16 | 0.211108E+10 | 0.00 | 1398163.41 | 61244610.52 | 0.00 | 50479464.63 | 0.00 | 0.45 |
February | 23729162.23 | 0.286196E+10 | 0.00 | 952096.47 | 0.127471E+09 | 0.00 | 35080578.85 | 0.00 | 0.46 |
March | 24168842.58 | 0.274714E+10 | 0.00 | 969684.21 | 0.104850E+09 | 0.00 | 45050629.19 | 0.00 | 0.46 |
April | 12761510.37 | 0.256309E+10 | 0.00 | 801270.39 | 98824339.09 | 0.00 | 17739110.85 | 0.00 | 0.46 |
May | 1060365.65 | 0.392191E+10 | 0.00 | 804286.57 | 0.197136E+09 | 0.00 | 1814641.01 | 0.00 | 0.46 |
June | 0.00 | 0.406491E+10 | 0.00 | 193674.56 | 0.213559E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.495371E+10 | 0.00 | 349219.31 | 0.279413E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
August | 0.00 | 0.523462E+10 | 0.00 | 440913.69 | 0.298127E+09 | 0.00 | 25212.13 | 0.00 | 0.46 |
September | 0.00 | 0.506277E+10 | 0.00 | 551142.62 | 0.299073E+09 | 0.00 | 170282.64 | 0.00 | 0.46 |
October | 543981.52 | 0.495849E+10 | 0.00 | 983813.50 | 0.272729E+09 | 0.00 | 1900615.31 | 0.00 | 0.46 |
November | 3563403.65 | 0.379366E+10 | 0.00 | 662965.49 | 0.167631E+09 | 0.00 | 3192830.49 | 0.00 | 0.46 |
December | 8829763.17 | 0.308644E+10 | 0.00 | 963133.20 | 0.125709E+09 | 0.00 | 9370703.14 | 0.00 | 0.45 |
Annual Sum or Average | 0.114338E+09 | 0.453598E+11 | 0.00 | 9070363.42 | 0.224577E+10 | 0.00 | 0.164824E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.211108E+10 | 0.00 | 193674.56 | 61244610.52 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 39680912.16 | 0.523462E+10 | 0.00 | 1398163.41 | 0.299073E+09 | 0.00 | 50479464.63 | 0.00 | 0.46 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 39983391.66 | 0.208837E+10 | 0.00 | 1317903.18 | 60822214.75 | 0.00 | 52833973.75 | 0.00 | 0.45 |
February | 23931446.00 | 0.283254E+10 | 0.00 | 892257.36 | 0.126870E+09 | 0.00 | 36331476.01 | 0.00 | 0.46 |
March | 24533417.28 | 0.271983E+10 | 0.00 | 886780.63 | 0.104362E+09 | 0.00 | 46820378.29 | 0.00 | 0.46 |
April | 12868188.00 | 0.253867E+10 | 0.00 | 733207.85 | 98470838.17 | 0.00 | 18506559.83 | 0.00 | 0.46 |
May | 1075488.11 | 0.389638E+10 | 0.00 | 740798.22 | 0.197560E+09 | 0.00 | 1822714.30 | 0.00 | 0.46 |
June | 0.00 | 0.403640E+10 | 0.00 | 175084.39 | 0.218003E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.493083E+10 | 0.00 | 318494.09 | 0.280538E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
August | 0.00 | 0.521017E+10 | 0.00 | 406341.43 | 0.298630E+09 | 0.00 | 25469.18 | 0.00 | 0.46 |
September | 0.00 | 0.504061E+10 | 0.00 | 520774.50 | 0.297923E+09 | 0.00 | 171913.00 | 0.00 | 0.46 |
October | 584956.15 | 0.493420E+10 | 0.00 | 919812.84 | 0.272133E+09 | 0.00 | 2023089.87 | 0.00 | 0.46 |
November | 3595998.94 | 0.376813E+10 | 0.00 | 608811.36 | 0.167869E+09 | 0.00 | 3327569.87 | 0.00 | 0.46 |
December | 8887633.04 | 0.305977E+10 | 0.00 | 903044.70 | 0.125888E+09 | 0.00 | 9965431.87 | 0.00 | 0.45 |
Annual Sum or Average | 0.115461E+09 | 0.450559E+11 | 0.00 | 8423310.54 | 0.224907E+10 | 0.00 | 0.171829E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.208837E+10 | 0.00 | 175084.39 | 60822214.75 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 39983391.66 | 0.521017E+10 | 0.00 | 1317903.18 | 0.298630E+09 | 0.00 | 52833973.75 | 0.00 | 0.46 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 25956875.38 | 0.388327E+10 | 0.00 | 2178921.17 | 55203141.22 | 0.00 | 75643311.32 | 0.00 | 0.42 |
February | 14330872.60 | 0.535588E+10 | 0.00 | 1246230.91 | 0.106653E+09 | 0.00 | 45901971.33 | 0.00 | 0.42 |
March | 16497034.21 | 0.517520E+10 | 0.00 | 1037097.14 | 81787962.84 | 0.00 | 31465030.99 | 0.00 | 0.43 |
April | 9563415.63 | 0.480824E+10 | 0.00 | 753973.20 | 89970211.76 | 0.00 | 12163901.36 | 0.00 | 0.42 |
May | 0.00 | 0.748886E+10 | 0.00 | 591772.74 | 0.162566E+09 | 0.00 | 438078.64 | 0.00 | 0.42 |
June | 0.00 | 0.770177E+10 | 0.00 | 137844.51 | 0.154013E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 443974.74 | 0.944363E+10 | 0.00 | 482467.05 | 0.228668E+09 | 0.00 | 1393341.27 | 0.00 | 0.42 |
August | 0.00 | 0.101236E+11 | 0.00 | 162081.80 | 0.202121E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.966727E+10 | 0.00 | 482617.90 | 0.232259E+09 | 0.00 | 112151.91 | 0.00 | 0.42 |
October | 92455.51 | 0.961203E+10 | 0.00 | 682039.98 | 0.224770E+09 | 0.00 | 701831.90 | 0.00 | 0.42 |
November | 4929272.31 | 0.714422E+10 | 0.00 | 174519.75 | 0.127370E+09 | 0.00 | 546960.42 | 0.00 | 0.42 |
December | 7376918.56 | 0.576124E+10 | 0.00 | 1626042.79 | 0.106038E+09 | 0.00 | 6779522.76 | 0.00 | 0.42 |
Annual Sum or Average | 79190818.94 | 0.861652E+11 | 0.00 | 9555608.93 | 0.177142E+10 | 0.00 | 0.175146E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.388327E+10 | 0.00 | 137844.51 | 55203141.22 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 25956875.38 | 0.101236E+11 | 0.00 | 2178921.17 | 0.232259E+09 | 0.00 | 75643311.32 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 13491203.92 | 0.192903E+10 | 0.00 | 1061954.51 | 25127758.04 | 0.00 | 38097296.47 | 0.00 | 0.42 |
February | 7415614.22 | 0.265759E+10 | 0.00 | 616756.74 | 51995652.33 | 0.00 | 22691817.10 | 0.00 | 0.42 |
March | 7788457.85 | 0.257027E+10 | 0.00 | 489636.28 | 39460357.88 | 0.00 | 16362098.64 | 0.00 | 0.43 |
April | 4947994.58 | 0.239013E+10 | 0.00 | 358773.80 | 43857319.47 | 0.00 | 6038984.81 | 0.00 | 0.42 |
May | 7265.02 | 0.373014E+10 | 0.00 | 273328.30 | 76262940.48 | 0.00 | 222762.13 | 0.00 | 0.42 |
June | 0.00 | 0.383461E+10 | 0.00 | 62654.72 | 74011614.12 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 223119.78 | 0.470650E+10 | 0.00 | 224044.96 | 0.110866E+09 | 0.00 | 668732.89 | 0.00 | 0.42 |
August | 0.00 | 0.504360E+10 | 0.00 | 81587.74 | 0.101464E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.481380E+10 | 0.00 | 233544.70 | 0.113974E+09 | 0.00 | 71759.42 | 0.00 | 0.42 |
October | 57983.65 | 0.479099E+10 | 0.00 | 335036.20 | 0.107226E+09 | 0.00 | 374295.77 | 0.00 | 0.42 |
November | 2603260.64 | 0.355698E+10 | 0.00 | 77612.52 | 59620871.87 | 0.00 | 298417.94 | 0.00 | 0.42 |
December | 3683742.56 | 0.286490E+10 | 0.00 | 763856.77 | 50360892.13 | 0.00 | 3489284.00 | 0.00 | 0.42 |
Annual Sum or Average | 40218642.22 | 0.428885E+11 | 0.00 | 4578787.26 | 0.854227E+09 | 0.00 | 88315449.18 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.192903E+10 | 0.00 | 62654.72 | 25127758.04 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 13491203.92 | 0.504360E+10 | 0.00 | 1061954.51 | 0.113974E+09 | 0.00 | 38097296.47 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 13659402.81 | 0.191931E+10 | 0.00 | 1041475.48 | 25029851.99 | 0.00 | 38830547.48 | 0.00 | 0.42 |
February | 7440110.77 | 0.264472E+10 | 0.00 | 607156.85 | 52087447.03 | 0.00 | 23111045.44 | 0.00 | 0.42 |
March | 8069044.98 | 0.255877E+10 | 0.00 | 475964.68 | 39246805.38 | 0.00 | 16543915.05 | 0.00 | 0.43 |
April | 4986407.60 | 0.238032E+10 | 0.00 | 344996.70 | 43639653.30 | 0.00 | 6178587.67 | 0.00 | 0.42 |
May | 6894.35 | 0.371968E+10 | 0.00 | 264626.59 | 76176319.57 | 0.00 | 221084.35 | 0.00 | 0.42 |
June | 0.00 | 0.382437E+10 | 0.00 | 59839.16 | 74119862.22 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 226768.83 | 0.469605E+10 | 0.00 | 218636.18 | 0.111466E+09 | 0.00 | 683712.15 | 0.00 | 0.42 |
August | 0.00 | 0.503380E+10 | 0.00 | 79408.30 | 0.101328E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.480337E+10 | 0.00 | 228462.54 | 0.113649E+09 | 0.00 | 72567.49 | 0.00 | 0.42 |
October | 60777.47 | 0.477885E+10 | 0.00 | 327849.94 | 0.109245E+09 | 0.00 | 376213.38 | 0.00 | 0.42 |
November | 2619823.76 | 0.354486E+10 | 0.00 | 76141.56 | 60499963.18 | 0.00 | 311689.15 | 0.00 | 0.42 |
December | 3687849.29 | 0.285396E+10 | 0.00 | 743311.66 | 50013776.46 | 0.00 | 3585471.55 | 0.00 | 0.42 |
Annual Sum or Average | 40757079.85 | 0.427581E+11 | 0.00 | 4467869.65 | 0.856501E+09 | 0.00 | 89914833.72 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.191931E+10 | 0.00 | 59839.16 | 25029851.99 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 13659402.81 | 0.503380E+10 | 0.00 | 1041475.48 | 0.113649E+09 | 0.00 | 38830547.48 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 13810486.04 | 0.190470E+10 | 0.00 | 994833.50 | 24986000.66 | 0.00 | 40478132.18 | 0.00 | 0.42 |
February | 7528158.86 | 0.262504E+10 | 0.00 | 572956.43 | 52006001.11 | 0.00 | 24018431.46 | 0.00 | 0.42 |
March | 8343872.51 | 0.254094E+10 | 0.00 | 440038.76 | 38824066.51 | 0.00 | 17419892.29 | 0.00 | 0.43 |
April | 5109220.15 | 0.236725E+10 | 0.00 | 313229.80 | 44081082.82 | 0.00 | 6482957.20 | 0.00 | 0.42 |
May | 24730.29 | 0.371287E+10 | 0.00 | 241643.55 | 75736012.91 | 0.00 | 192415.27 | 0.00 | 0.42 |
June | 0.00 | 0.382171E+10 | 0.00 | 52503.43 | 70653432.63 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 192687.63 | 0.469552E+10 | 0.00 | 202929.87 | 0.108679E+09 | 0.00 | 756842.00 | 0.00 | 0.42 |
August | 0.00 | 0.503637E+10 | 0.00 | 74811.33 | 97033936.88 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.479852E+10 | 0.00 | 219126.28 | 0.113479E+09 | 0.00 | 72204.81 | 0.00 | 0.42 |
October | 66078.24 | 0.477488E+10 | 0.00 | 312335.01 | 0.108280E+09 | 0.00 | 374021.88 | 0.00 | 0.42 |
November | 2654862.28 | 0.353476E+10 | 0.00 | 65239.10 | 59745410.12 | 0.00 | 366539.30 | 0.00 | 0.42 |
December | 3718996.07 | 0.284085E+10 | 0.00 | 694867.27 | 49210282.03 | 0.00 | 3756879.76 | 0.00 | 0.42 |
Annual Sum or Average | 41449092.08 | 0.426534E+11 | 0.00 | 4184514.34 | 0.842714E+09 | 0.00 | 93918316.16 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.190470E+10 | 0.00 | 52503.43 | 24986000.66 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 13810486.04 | 0.503637E+10 | 0.00 | 994833.50 | 0.113479E+09 | 0.00 | 40478132.18 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 11587489.13 | 0.190202E+10 | 0.00 | 1003792.33 | 18906801.12 | 0.00 | 52874949.04 | 0.00 | 0.42 |
February | 11623669.93 | 0.259611E+10 | 0.00 | 562133.54 | 42837755.00 | 0.00 | 28604455.95 | 0.00 | 0.42 |
March | 16709256.06 | 0.250390E+10 | 0.00 | 450065.72 | 30908690.75 | 0.00 | 22551028.19 | 0.00 | 0.43 |
April | 4194710.54 | 0.237490E+10 | 0.00 | 307199.39 | 34501587.30 | 0.00 | 11446598.31 | 0.00 | 0.42 |
May | 67522.64 | 0.375555E+10 | 0.00 | 366775.92 | 58064515.07 | 0.00 | 289705.25 | 0.00 | 0.42 |
June | 0.00 | 0.385891E+10 | 0.00 | 182207.35 | 48893051.17 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 102004.61 | 0.474151E+10 | 0.00 | 420609.73 | 91721562.00 | 0.00 | 2094270.48 | 0.00 | 0.42 |
August | 0.00 | 0.509054E+10 | 0.00 | 275450.50 | 75838975.57 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.480241E+10 | 0.00 | 363468.66 | 99496222.42 | 0.00 | 80140.60 | 0.00 | 0.42 |
October | 152148.37 | 0.481540E+10 | 0.00 | 383607.13 | 93695386.81 | 0.00 | 650928.92 | 0.00 | 0.42 |
November | 2954788.34 | 0.353780E+10 | 0.00 | 324029.45 | 44434802.25 | 0.00 | 931591.79 | 0.00 | 0.42 |
December | 4841575.97 | 0.284610E+10 | 0.00 | 731100.42 | 35618140.36 | 0.00 | 6824196.91 | 0.00 | 0.42 |
Annual Sum or Average | 52233165.58 | 0.428251E+11 | 0.00 | 5370440.13 | 0.674917E+09 | 0.00 | 0.126348E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.190202E+10 | 0.00 | 182207.35 | 18906801.12 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 16709256.06 | 0.509054E+10 | 0.00 | 1003792.33 | 99496222.42 | 0.00 | 52874949.04 | 0.00 | 0.43 |