Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
Simulation Timestamp: 2023-10-16 10:43:17
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1260.05 | 260.60 | 260.60 |
Net Site Energy | 1154.11 | 238.69 | 238.69 |
Total Source Energy | 2029.07 | 419.65 | 419.65 |
Net Source Energy | 1693.57 | 350.26 | 350.26 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 941.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 6.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 75.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 42.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 32.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 26.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 318.38 | 941.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 941.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 6.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 75.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 42.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 31.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 26.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | DCtoACInverter Ancillary | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 941.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 6.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 75.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 42.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 32.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 26.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 24.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.32 | 194.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 65.85 | 194.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 24.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.32 | 194.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 65.85 | 194.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 110.924 | 34.84 |
Wind Power | 0.000 | 0.00 |
Power Conversion | -4.99 | -1.6 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 105.935 | 33.27 |
Electricity Coming From Utility | 227.449 | 71.44 |
Surplus Electricity Going To Utility | 15.008 | 4.71 |
Net Electricity From Utility | 212.441 | 66.73 |
Total On-Site and Utility Electric Sources | 318.376 | 100.00 |
Total Electricity End Uses | 318.376 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 74.17 |
Time Setpoint Not Met During Occupied Cooling | 2.33 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3042.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2022
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
| Environment |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EnergyConsumptionElectricityGeneratedPropaneMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE | ZONE2 FINE STORAGEPEOPLE | ZONE3 BULK STORAGEPEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| ZONE2 FINE STORAGE_DAYLCTRL | ZONE3 BULK STORAGE_DAYLCTRL | ZONE1 OFFICE_DAYLCTRL |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATER ZONE3HIRADIANT FAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43 |
RunPeriod | RUNPERIOD 1 |
Weather File | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Latitude [deg] | 42.93 |
Longitude [deg] | -78.7 |
Elevation [m] | 215.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 68.38 |
Skylight-Roof Ratio [%] | 1.49 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 6.1633 | 18.58 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 6.6844 | 46.45 | 0.0000 |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 3.1969 | 46.45 | 2.5587 |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.3473 | 43.27 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.3473 | 43.27 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1.00 | ZONE1 OFFICE | GENERAL | ZONE1 OFFICE | 6.1633 | 18.58 | 8.0737 | |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 1.00 | ZONE2 FINE STORAGE | GENERAL | ZONE2 FINE STORAGE | 6.6844 | 46.45 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 1.00 | ZONE3 BULK STORAGE | GENERAL | ZONE3 BULK STORAGE | 3.1969 | 46.45 | 2.5587 | |
Total | 4835.13 | 4.3473 | 21.63 | 2.0915 | |||||||
Conditioned Total | 4835.13 | 4.3473 | 21.63 | 2.0915 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4835.13 | 4835.13 | 0.00 | 0.00 | 4.3473 | 43.27 | 2.0915 |
Total | 4835.13 | 4835.13 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 19-JUL-14:30 | 12-JAN-08:00 | - | - | - | - | - | - | - | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 295838.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 7773.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 4299.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 4154.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1758.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 28020.85 | 295838.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 295838.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 7773.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 4299.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 1849.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1758.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | DCtoACInverter Ancillary | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1020.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 19.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 238.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 133.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 432.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 101.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 83.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1008.30 | 1020.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 211.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 3.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 49.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 27.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 89.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 21.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 208.54 | 211.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 211.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 3.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 49.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 27.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 89.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 21.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 208.54 | 211.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 0.928681 |
ZONE2 FINE STORAGE DIRECT AIR | 1.92 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3 BULK STORAGE UNIT HEATER | 4.47 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | 4.47 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | 178543.76 |
PSZ-OFFICE HEATING COIL | 25267.59 |
PSZ-FINE STORAGE HEATING COIL | 71306.30 |
User-Specified Heating Design Capacity [W] | |
ZONE3 BULK STORAGE HIRADIANT | 178543.77 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 0.928681 | 0.928681 | 0.928681 | 0.928681 | 0.928681 | 0.928681 | 1.00 | 1.00 | 0.928681 |
PSZ-FINE STORAGE | 1.92 | 1.92 | 1.92 | 1.92 | 1.92 | 1.92 | 1.00 | 1.00 | 1.92 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE_OA_CONTROLLER | 0.928681 | 0.102285 |
PSZ-FINE STORAGE_OA_CONTROLLER | 1.92 | 0.424711 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 0.928681 | 1028.20 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 1.92 | 2053.59 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 0.928681 | 0.928681 | 0.928681 | 0.928681 | 17562.21 | 25267.59 | 40.00 | 1.00 |
PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | 1.92 | 1.92 | 1.92 | 1.27 | 47450.86 | 71306.30 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 0.928680 | 0.464341 | 0.619120 | 17562.21 | 8781.10 | 0.798820 | 0.798820 |
PSZ-FINE STORAGE COOLING COIL | 1.92 | 0.959579 | 1.28 | 47450.86 | 23725.43 | 0.703150 | 0.703150 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT DOOR | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | |
OFFICE LEFT WALL | OFFICE LEFT WALL DOOR | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
FINE STORAGE ROOF | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.70 | 6.00 | -2.20 | -3.40 | -4.20 | 2.70 | 7.50 | 13.70 | 18.60 | 22.00 | 20.70 | 16.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 | 42.93 | -78.73 | -5.00 | 215.00 | 98769 | 1.1739 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 8.97 | 26.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 102 | 78 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 20.81 | 11 | 20 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 47.57 | 6 | 52 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 12.7 | 18.581 | 5.382E-002 | 6.163 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 14.237 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 46.447 | 2.153E-002 | 6.684 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.684 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 46.447 | 2.153E-002 | 3.197 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 5.756 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 12.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 13 |
2 | ZONE2 FINE STORAGEPEOPLE | BLDG_OCC_SCH | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 30.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE2 FINE STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 30 |
3 | ZONE3 BULK STORAGEPEOPLE | BLDG_OCC_SCH | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 69.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE3 BULK STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 69 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | LTG_SCH_OFFICE | ZONE1 OFFICE | 236.88 | 12.7 | 1459.960 | 6.163 | 114.518 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 1459.960 |
2 | FINE STORAGE AREA LIGHTS | LTG_SCH_FINE_STORAGE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 9314.081 | 6.684 | 310.469 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 9314.081 |
3 | BULK STORAGE AREA LIGHTS | LTG_SCH_BULK_STORAGE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 10245.499 | 3.197 | 148.485 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 10245.499 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 1912.500 | 8.074 | 150.015 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 8200.120 | 2.559 | 118.842 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.2163 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.4974 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL_GRD | 19 | 3 | 4 | 0.167 | 0.3330 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL_GRD | 25 | 3 | 4 | 0.167 | 0.6144 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 41 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 42 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 44 | 1 | 1 | 0.167 | 2.044 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 45 | 1 | 1 | 0.167 | 1.760 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 46 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 47 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 48 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1926 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 50 | 2 | 7 | 0.167 | 0.7922E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 51 | 2 | 7 | 0.167 | 0.7415E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 52 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL_GRD | 53 | 3 | 4 | 0.167 | 0.6144 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 54 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.622 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.010 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.904 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.528 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4892 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5681 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.116 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.55 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 13.41 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.528 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.18741198E-13 | -0.13599760E-18 | 0.18147593E-18 | 0.0000000 |
2 | 1 | -5.2160601 | 0.51384690E-04 | -0.74050972E-04 | 0.35929797E-14 |
3 | 0 | 5.4323994 | 0.21628790 | 0.21641333 | |
4 | 2 | 0.53330648E-11 | 0.17872838E-15 | 0.22136589E-15 | 0.0000000 |
5 | 1 | -5.2159880 | 0.41449123E-04 | -0.32205733E-04 | 0.68736940E-11 |
6 | 0 | 5.7134214 | 0.49739196 | 0.49746561 | |
7 | 4 | 0.81205461E-12 | -0.60820818E-16 | 0.53959138E-14 | 0.11194769E-15 |
8 | 3 | -0.39487908E-03 | 0.23668407E-06 | -0.57379545E-04 | 0.15580508E-12 |
9 | 2 | 1.7634853 | 0.51193665E-02 | 1.1586669 | -0.75705256E-04 |
10 | 1 | -7.0973464 | 0.13173731 | -17.214220 | 0.33800211 |
11 | 0 | 5.5547270 | 0.83614094E-01 | 16.276082 | |
12 | 4 | 0.75524091E-12 | 0.18585927E-15 | -0.24619336E-14 | 0.12165746E-15 |
13 | 3 | -0.37591709E-03 | 0.42679598E-06 | -0.54444663E-04 | 0.14493025E-12 |
14 | 2 | 1.7186597 | 0.94202666E-02 | 1.1245767 | -0.72068922E-04 |
15 | 1 | -7.1564116 | 0.24550773 | -16.996678 | 0.32938266 |
16 | 0 | 5.8501984 | 0.15714209 | 16.284226 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 2.0441747 | 2.0441747 | 2.0441747 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 1.7602615 | 1.7602615 | 1.7602615 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.21936956E-08 | -0.76657665E-15 | 0.52174295E-14 | -0.76362207E-16 |
55 | 6 | 0.54250385E-05 | 0.36865710E-08 | 0.31904099E-02 | -0.26763832E-04 |
56 | 5 | -0.38781740E-03 | 0.21819055E-05 | -0.22375527 | 0.19564212E-02 |
57 | 4 | 0.89061350E-02 | 0.99303795E-04 | 4.8300570 | -0.45269896E-01 |
58 | 3 | -0.78164548E-01 | 0.78949647E-03 | -38.024306 | 0.39868569 |
59 | 2 | 0.27748674 | 0.13132576E-02 | 116.48957 | -1.4180145 |
60 | 1 | -0.40047331 | 0.39992572E-03 | -143.91062 | 2.0490943 |
61 | 0 | 0.19524127 | 0.97244710E-05 | 60.838472 | |
62 | 7 | -0.53942680E-08 | -0.11156834E-13 | 0.16318657E-14 | -0.36257882E-16 |
63 | 6 | 0.25438785E-05 | 0.15223906E-08 | 0.31992327E-02 | -0.26837845E-04 |
64 | 5 | -0.16605865E-03 | 0.89659996E-06 | -0.22425660 | 0.19608463E-02 |
65 | 4 | 0.37075836E-02 | 0.40698259E-04 | 4.8384045 | -0.45350141E-01 |
66 | 3 | -0.32199378E-01 | 0.32283529E-03 | -38.071448 | 0.39920679 |
67 | 2 | 0.11382527 | 0.53586778E-03 | 116.58131 | -1.4192416 |
68 | 1 | -0.16395953 | 0.16275009E-03 | -143.96461 | 2.0499819 |
69 | 0 | 0.79856572E-01 | 0.39490086E-05 | 60.838472 | |
70 | 7 | -0.57660871E-08 | -0.13610624E-13 | 0.89936022E-15 | -0.28491615E-16 |
71 | 6 | 0.24333103E-05 | 0.14269892E-08 | 0.31996257E-02 | -0.26841142E-04 |
72 | 5 | -0.15663594E-03 | 0.83977476E-06 | -0.22427892 | 0.19610433E-02 |
73 | 4 | 0.34808858E-02 | 0.38103208E-04 | 4.8387759 | -0.45353710E-01 |
74 | 3 | -0.30176241E-01 | 0.30214868E-03 | -38.073544 | 0.39922996 |
75 | 2 | 0.10659492 | 0.50136596E-03 | 116.58539 | -1.4192962 |
76 | 1 | -0.15349297 | 0.15221123E-03 | -143.96701 | 2.0500213 |
77 | 0 | 0.74745977E-01 | 0.36906361E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.24619336E-14 | 0.18585927E-15 | 0.75524091E-12 | 0.12165746E-15 |
85 | 3 | -0.54444663E-04 | 0.42679598E-06 | -0.37591709E-03 | 0.14493025E-12 |
86 | 2 | 1.1245767 | 0.94202666E-02 | 1.7186597 | -0.72068922E-04 |
87 | 1 | -16.996678 | 0.24550773 | -7.1564116 | 0.32938266 |
88 | 0 | 16.284226 | 0.15714209 | 5.8501984 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.362_SHGC_SOUTH_0.379 | 34 | 1 | VerySmooth | 2.057 | 2.057 | 1.000 | 0.380 | ||
2 | NONRESWINDOW_U_0.362_SHGC_NORTH_0.379 | 35 | 1 | VerySmooth | 2.057 | 2.057 | 1.000 | 0.380 | ||
3 | NONRESWINDOW_U_0.362_SHGC_EAST_0.379 | 36 | 1 | VerySmooth | 2.057 | 2.057 | 1.000 | 0.380 | ||
4 | NONRESWINDOW_U_0.362_SHGC_WEST_0.379 | 37 | 1 | VerySmooth | 2.057 | 2.057 | 1.000 | 0.380 | ||
5 | SKYLIGHT_U_0.5_SHGC_0.4 | 38 | 1 | VerySmooth | 2.843 | 2.843 | 1.000 | 0.401 | ||
6 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | 39 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.555 | ||
7 | SKYLIGHT DOUBLE CLEAR | 43 | 3 | VerySmooth | 3.715 | 3.715 | 1.000 | 0.720 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER SOUTH | SpectralAverage | 3.63679E-002 | 0.29270 | 0.50147 | 0.50147 | 0.37900 | 0.13994 | 0.18549 | 0.00000 | 0.84000 | 0.84000 | 0.11599 | 1.00000 | No | |
2 | NONRES WINDOW GLAZING LAYER NORTH | SpectralAverage | 3.63679E-002 | 0.29270 | 0.50147 | 0.50147 | 0.37900 | 0.13994 | 0.18549 | 0.00000 | 0.84000 | 0.84000 | 0.11599 | 1.00000 | No | |
3 | NONRES WINDOW GLAZING LAYER EAST | SpectralAverage | 3.63679E-002 | 0.29270 | 0.50147 | 0.50147 | 0.37900 | 0.13994 | 0.18549 | 0.00000 | 0.84000 | 0.84000 | 0.11599 | 1.00000 | No | |
4 | NONRES WINDOW GLAZING LAYER WEST | SpectralAverage | 3.63679E-002 | 0.29270 | 0.50147 | 0.50147 | 0.37900 | 0.13994 | 0.18549 | 0.00000 | 0.84000 | 0.84000 | 0.11599 | 1.00000 | No | |
5 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 1.97990E-002 | 0.31435 | 0.46556 | 0.46556 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.10909 | 1.00000 | No | |
6 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.41263 | 0.18041 | 0.18041 | 0.55000 | 0.12964 | 0.15485 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
7 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
8 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | ZONE1 OFFICE | 4 | 0 |
2 | ZONE2 FINE STORAGE | 14 | 0 |
3 | ZONE3 BULK STORAGE | 32 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | ZONE1 OFFICE | 0 | |
2 | ZONE2 FINE STORAGE | 0 | |
3 | ZONE3 BULK STORAGE | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 7.5708E-002 | 6154.7 | 1.055 | 0.5319 |
Construction Name | Frame and Divider Name | NFRC Product Type | Assembly U-Factor {W/m2-K} | Assembly SHGC | Assembly Visible Transmittance | |
1 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | CurtainWall | 2.775 | 0.408 | 0.402 |
2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | CurtainWall | 4.099 | 0.553 | 0.552 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 12.7 | 8.518E-002 | 3.596E-004 | 5.551E-004 | 0.303 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 0.177 | 7.451E-004 | 1.150E-003 | 0.629 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 0.433 | 3.110E-004 | 1.981E-004 | 0.528 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 2.331 | 7.274E-004 | 4.751E-004 | 0.238 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 37.760 | 1.178E-002 | 0.547 | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 0.944 | 2.945E-004 | 1.368E-002 | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.6355E-005 |
2 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.6770E-004 |
3 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.6108E-005 |
4 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.8663E-004 |
5 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.5136E-005 |
6 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.1116E-004 |
7 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5724E-005 |
8 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.5867E-004 |
9 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.6428E-004 |
10 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.9639E-004 |
11 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3670E-004 |
12 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.2415E-004 |
13 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5148E-004 |
14 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.7016E-004 |
15 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.3414E-004 |
16 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.4540E-004 |
17 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.6456E-004 |
18 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.4525E-004 |
19 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.0304E-004 |
20 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5910E-004 |
21 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.5406E-004 |
22 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1648E-004 |
23 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.8792E-004 |
24 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.6675E-005 |
25 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.4479E-004 |
26 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.5618E-005 |
27 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.7534E-004 |
28 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.1512E-005 |
29 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0129E-003 |
30 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.2432E-005 |
31 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3392E-003 |
32 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.0724E-005 |
33 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.2194E-004 |
34 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.2990E-005 |
35 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.2871E-004 |
36 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.5558E-005 |
37 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.3632E-004 |
38 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.8775E-005 |
39 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.9718E-004 |
40 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.6272E-005 |
41 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.4665E-004 |
42 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.3878E-005 |
43 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.7671E-004 |
44 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.5072E-005 |
45 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.3438E-004 |
46 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.3952E-005 |
47 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7955E-004 |
48 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.4789E-005 |
49 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0668E-003 |
50 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.6698E-005 |
51 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2971E-003 |
52 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.8678E-005 |
53 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.1451E-004 |
54 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.4530E-005 |
55 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.3679E-004 |
56 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.4861E-005 |
57 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.8204E-003 |
58 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.1509E-005 |
59 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0576E-003 |
60 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.6475E-005 |
61 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.8529E-003 |
62 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.0627E-005 |
63 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1133E-003 |
64 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.6508E-005 |
65 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5548E-003 |
66 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1678E-004 |
67 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4530E-003 |
68 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3157E-004 |
69 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.3618E-003 |
70 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.9711E-005 |
71 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.5808E-003 |
72 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.1684E-005 |
73 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.9730E-004 |
74 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.9080E-004 |
75 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.9523E-004 |
76 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.4698E-004 |
77 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.6152E-004 |
78 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5344E-004 |
79 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.6286E-003 |
80 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.1734E-005 |
81 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0850E-004 |
82 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.1236E-004 |
83 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7107E-004 |
84 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1163E-003 |
85 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.9648E-004 |
86 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.7584E-004 |
87 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.3102E-004 |
88 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8162E-004 |
89 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.4860E-005 |
90 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.6931E-003 |
91 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.2565E-005 |
92 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.9607E-003 |
93 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.1721E-005 |
94 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5217E-003 |
95 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0760E-004 |
96 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.8446E-004 |
97 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.2713E-005 |
98 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.7433E-003 |
99 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.8282E-005 |
100 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.7044E-003 |
101 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.8727E-005 |
102 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.5243E-003 |
103 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.7398E-005 |
104 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.1825E-003 |
105 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.0796E-005 |
106 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.7874E-004 |
107 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.6837E-005 |
108 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.2108E-004 |
109 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.7490E-005 |
110 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0673E-003 |
111 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.5431E-005 |
112 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2422E-003 |
113 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.9914E-005 |
114 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.4234E-005 |
115 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.3288E-005 |
116 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1312E-005 |
117 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.1140E-005 |
118 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5885E-005 |
119 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.0686E-005 |
120 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.8896E-005 |
121 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.0588E-005 |
122 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.8611E-005 |
123 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.8531E-005 |
124 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0054E-005 |
125 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.3023E-005 |
126 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8656E-005 |
127 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.3969E-005 |
128 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1488E-005 |
129 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.8726E-005 |
130 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.0046E-005 |
131 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.2751E-005 |
132 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.8623E-005 |
133 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.2883E-005 |
134 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.0505E-005 |
135 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.0664E-005 |
136 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.2423E-005 |
137 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6154E-004 |
138 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.1693E-004 |
139 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9969E-004 |
140 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.4844E-004 |
141 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7830E-004 |
142 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4344E-004 |
143 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.5103E-005 |
144 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.2222E-005 |
145 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.7866E-005 |
146 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4043E-004 |
147 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0087E-004 |
148 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3182E-004 |
149 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1779E-005 |
150 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2173E-004 |
151 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.1117E-005 |
152 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.0201E-005 |
153 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3094E-004 |
154 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7652E-005 |
155 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4297E-004 |
156 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7689E-005 |
157 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0239E-004 |
158 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7355E-005 |
159 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.1095E-005 |
160 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.2472E-005 |
161 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.0645E-004 |
162 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.0960E-005 |
163 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.8997E-004 |
164 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.4377E-005 |
165 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0458E-004 |
166 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1847E-005 |
167 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.5083E-005 |
168 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1405E-005 |
169 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4067E-004 |
170 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1325E-003 |
171 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4086E-004 |
172 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3760E-003 |
173 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5204E-004 |
174 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5103E-004 |
175 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.6080E-005 |
176 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3729E-004 |
177 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.6035E-004 |
178 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7180E-004 |
179 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.3770E-004 |
180 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.1805E-004 |
181 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.6060E-004 |
182 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.0225E-004 |
183 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0654E-004 |
184 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4057E-004 |
185 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.7925E-004 |
186 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0019E-004 |
187 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0550E-003 |
188 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0174E-004 |
189 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.4169E-004 |
190 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8768E-005 |
191 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0642E-004 |
192 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5894E-005 |
193 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8894E-004 |
194 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0738E-005 |
195 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0104E-004 |
196 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0064E-005 |
197 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7454E-004 |
198 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1903E-005 |
199 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.6000E-005 |
200 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5319E-005 |
201 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4300E-003 |
202 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1500E-004 |
203 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6225E-003 |
204 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1180E-004 |
205 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3878E-003 |
206 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3051E-004 |
207 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.2332E-004 |
208 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.0027E-005 |
209 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0448E-003 |
210 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3860E-004 |
211 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1276E-003 |
212 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6899E-004 |
213 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2066E-003 |
214 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.1429E-004 |
215 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.2412E-004 |
216 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.4700E-004 |
217 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4202E-004 |
218 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2600E-005 |
219 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4294E-004 |
220 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1028E-005 |
221 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.8484E-004 |
222 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5689E-005 |
223 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7391E-004 |
224 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8641E-005 |
225 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8917E-004 |
226 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0187E-003 |
227 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7982E-004 |
228 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3340E-003 |
229 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4500E-004 |
230 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8438E-003 |
231 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7417E-004 |
232 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.5926E-004 |
233 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4593E-004 |
234 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2390E-005 |
235 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2829E-004 |
236 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0096E-005 |
237 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4685E-004 |
238 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6549E-005 |
239 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7422E-004 |
240 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1060E-005 |
241 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4708E-003 |
242 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1541E-004 |
243 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4502E-003 |
244 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0701E-004 |
245 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1289E-003 |
246 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4390E-004 |
247 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2266E-003 |
248 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1357E-004 |
249 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2495E-003 |
250 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5309E-004 |
251 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1869E-003 |
252 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2370E-004 |
253 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8972E-003 |
254 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.3475E-004 |
255 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2308E-003 |
256 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1830E-004 |
257 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1018E-004 |
258 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.1854E-003 |
259 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8810E-004 |
260 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.1811E-003 |
261 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9925E-004 |
262 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.0822E-003 |
263 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7477E-004 |
264 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.6474E-003 |
265 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9258E-004 |
266 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0112E-005 |
267 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6879E-004 |
268 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7566E-005 |
269 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6640E-004 |
270 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3631E-005 |
271 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7271E-004 |
272 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1031E-005 |
273 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8175E-004 |
274 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1274E-003 |
275 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5584E-004 |
276 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.6027E-004 |
277 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3377E-004 |
278 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5875E-003 |
279 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7326E-004 |
280 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.5789E-003 |
281 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.2069E-004 |
282 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0016E-004 |
283 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0385E-004 |
284 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.0089E-005 |
285 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2190E-003 |
286 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2207E-004 |
287 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1930E-003 |
288 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1325E-004 |
289 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8638E-004 |
290 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7965E-004 |
291 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6418E-004 |
292 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.2832E-004 |
293 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1156E-003 |
294 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7195E-004 |
295 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1970E-003 |
296 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1180E-004 |
297 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2914E-004 |
298 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.2063E-004 |
299 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0900E-004 |
300 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.3839E-004 |
301 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3250E-004 |
302 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5478E-004 |
303 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7207E-004 |
304 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.2995E-004 |
305 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4891E-004 |
306 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0829E-004 |
307 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.8105E-004 |
308 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.7382E-004 |
309 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.6958E-004 |
310 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.4391E-004 |
311 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0466E-004 |
312 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.4053E-004 |
313 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9645E-005 |
314 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9542E-005 |
315 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.8074E-005 |
316 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5869E-005 |
317 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4268E-005 |
318 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7021E-005 |
319 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.3950E-005 |
320 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1198E-005 |
321 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2845E-004 |
322 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6651E-005 |
323 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1034E-004 |
324 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4302E-005 |
325 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4662E-004 |
326 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8608E-005 |
327 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7182E-004 |
328 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8575E-005 |
329 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.5453E-005 |
330 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.6806E-004 |
331 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3234E-005 |
332 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3569E-004 |
333 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.4626E-005 |
334 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4056E-004 |
335 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.4996E-005 |
336 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3143E-004 |
337 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5284E-004 |
338 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1212E-004 |
339 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2395E-004 |
340 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.4330E-005 |
341 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2605E-004 |
342 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0325E-004 |
343 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0188E-004 |
344 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3821E-004 |
345 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.3488E-005 |
346 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3068E-005 |
347 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.2570E-005 |
348 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.1158E-005 |
349 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9613E-005 |
350 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3863E-005 |
351 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.4918E-005 |
352 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5252E-005 |
353 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4546E-004 |
354 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.9175E-005 |
355 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.8118E-004 |
356 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.0720E-005 |
357 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.9326E-004 |
358 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.6063E-005 |
359 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0389E-004 |
360 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.9465E-005 |
361 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5037E-004 |
362 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.1400E-005 |
363 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2288E-004 |
364 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5533E-005 |
365 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3107E-004 |
366 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0226E-005 |
367 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0177E-004 |
368 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5496E-005 |
369 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 5.1378E-003 |
370 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.1693E-004 |
371 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.5524E-003 |
372 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.5157E-004 |
373 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.4241E-003 |
374 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.3233E-004 |
375 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.7098E-003 |
376 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 4.7591E-004 |
377 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.2849E-004 |
378 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.7727E-003 |
379 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.7675E-004 |
380 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 4.8221E-003 |
381 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.4363E-004 |
382 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 4.7486E-003 |
383 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 4.7049E-004 |
384 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.6445E-003 |
385 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 4.9310E-003 |
386 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.5677E-004 |
387 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.7156E-003 |
388 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.8123E-004 |
389 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.5387E-003 |
390 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.1174E-004 |
391 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.3987E-003 |
392 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.8991E-004 |
393 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.1394E-003 |
394 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.5753E-004 |
395 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.8162E-003 |
396 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.8163E-004 |
397 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.3235E-003 |
398 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.1131E-004 |
399 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.3986E-003 |
400 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.8991E-004 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 9169.46658 | 11003.35990 | 0.77390 | 0.92868 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 29.24600 | 1.33651E-002 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 10877.54593 | 13053.05511 | 0.31319 | 0.37583 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -16.30000 | 9.24091E-004 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 24306.72838 | 29168.07406 | 1.59930 | 1.91916 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 30.30000 | 1.33670E-002 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 37187.31968 | 44624.78362 | 0.90180 | 1.08215 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | -16.30000 | 9.24091E-004 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 30.30000 | 1.33670E-002 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
6 | ZONE3 BULK STORAGE | Heating | 148786.47244 | 178543.76693 | 3.72861 | 4.47433 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | -16.30000 | 9.24091E-004 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 13699.79 | 0.92868 | 0.92868 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 12908.29 | 0.37583 | 0.37583 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 35076.43 | 1.91916 | 1.91916 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 47167.08 | 1.08215 | 1.08215 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92868 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.91916 |
3 | ZoneHVAC:UnitHeater | ZONE3 BULK STORAGE UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 4.47433 |
4 | Fan:ConstantVolume | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Design Size Maximum Flow Rate [m3/s] | 4.47433 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Design Size Nominal Capacity [W] | 178543.76089 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3 BULK STORAGE HIRADIANT | User-Specified Heating Design Capacity [W] | 178543.76693 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92868 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92868 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92868 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92868 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92868 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.92868 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.91916 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.91916 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.91916 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.91916 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.91916 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 1.91916 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 0.92868 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 1.91916 |
25 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92868 |
26 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92868 |
28 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1028.19729 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92868 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92868 |
31 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92868 |
32 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92868 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92868 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46434 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.61912 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 17562.21000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 8781.10500 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.79882 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.79882 |
40 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17562.21000 |
41 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25267.59042 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
44 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 25267.59042 |
45 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.91916 |
46 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
47 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.91916 |
48 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2053.58969 |
49 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.91916 |
50 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.91916 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.91916 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.26664 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.91916 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.95958 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.27944 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 47450.86000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 23725.43000 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.70315 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.70315 |
60 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 47450.86000 |
61 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 71306.30334 |
62 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
63 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
64 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 71306.30334 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 16841.2 | 13.49 | 13.19 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 45959.1 | 13.08 | 12.78 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.1941478274 | 0.1745020212 | Pass | Pass | 0.5514658782 | 2.0188709343 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.4564162351 | 0.4244500057 | Pass | Pass | 0.4145396983 | 0.7163689604 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 3.5333187450E-005 | 6.1010501703E-005 | Pass | Pass | 2.7529453096E-002 | 1.9887784319E-002 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 8201.41 | 771.15 | 0.00 | 76.54 | 210.00 | 9259.15 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | -16.30 | 0.00 | -16.30 | Wetbulb [C] | 5.10 | 270.00 |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 30.30 | 9.30 | 21.80 | Wetbulb [C] | 5.70 | 240.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 0.00 | 0 | |||
Apr | 0.00 | 0 | |||
May | 44.00 | 33 | |||
Jun | 0.00 | 0 | |||
Jul | 0.00 | 0 | |||
Aug | 0.00 | 0 | |||
Sep | 67.00 | 33 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 39.02 | 30.56 | 0.00 | 90.00 | N |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.187 | 0.193 | 236.88 | 236.88 | 90.00 | 180.00 | |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.317 | 0.333 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.078 | 0.079 | 1156.53 | 1156.53 | 90.00 | 180.00 | |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.210 | 0.216 | 1393.41 | 1372.60 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.563 | 0.614 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.563 | 0.614 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.563 | 0.614 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.073 | 0.074 | 3204.84 | 3204.84 | 90.00 | 180.00 | |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.466 | 0.497 | 3204.84 | 3157.28 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE RIGHT WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 180.00 | 90.00 | S |
OFFICE REAR WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 90.00 | 90.00 | E |
OFFICE ROOF | INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 90.00 | 0.00 | |
iz-OFFICE RIGHT WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 0.00 | 90.00 | N |
iz-OFFICE REAR WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 270.00 | 90.00 | W |
iz-BULK STORAGE FRONT WALL | iz-SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.536 | 0.614 | 390.15 | 390.15 | 270.00 | 90.00 | W |
iz-OFFICE ROOF | iz-INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 270.00 | 180.00 | |
BULK STORAGE FRONT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.536 | 0.614 | 390.15 | 390.15 | 90.00 | 90.00 | E |
BULK STORAGE PRODUCTS SURFACE | BULK STORAGE PRODUCTS | 0.30 | 0.591 | 6028.45 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.362_SHGC_WEST_0.379 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.057 | 0.380 | 0.380 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.362_SHGC_WEST_0.379 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.057 | 0.380 | 0.380 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.362_SHGC_NORTH_0.379 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.057 | 0.380 | 0.380 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.362_SHGC_NORTH_0.379 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.057 | 0.380 | 0.380 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
FINESTORAGE_SKYLIGHT_1 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_6 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_7 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_8 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_9 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_10 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_5 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_4 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_3 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_2 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_14 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_13 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_12 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_U_0.5_SHGC_0.4 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 2.843 | 0.401 | 0.402 | 0.000 | 0.000 | CurtainWall | 2.775 | 0.408 | 0.402 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.55 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.555 | 0.552 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.553 | 0.552 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
Total or Average | 86.04 | 3.466 | 0.482 | 0.480 | |||||||||||||||||
North Total or Average | 6.51 | 2.057 | 0.380 | 0.380 | |||||||||||||||||
Non-North Total or Average | 79.53 | 3.581 | 0.490 | 0.488 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.565 | 2.044 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE LEFT WALL |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FINESTORAGE_SKYLIGHT_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_6 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_7 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_8 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_9 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_10 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_14 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_13 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | ZONE1 OFFICE | GENERAL | 6.1633 | 236.88 | 1459.96 | LightsWired | LTG_SCH_OFFICE | 44.65 | 168.00 | 28.17 | 0.0000 | Y | 7.72 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE | GENERAL | 6.6844 | 1393.41 | 9314.08 | LightsWired | LTG_SCH_FINE_STORAGE | 27.11 | 168.00 | 19.74 | 0.0000 | Y | 34.50 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE | GENERAL | 3.1969 | 3204.84 | 10245.50 | LightsWired | LTG_SCH_BULK_STORAGE | 27.11 | 168.00 | 17.14 | 0.0000 | Y | 32.97 |
Interior Lighting Total | 4.3473 | 4835.13 | 21019.54 | 75.20 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
ZONE2 FINE STORAGE_DAYLREFPT1 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 9314.08 | 2328.52 |
ZONE2 FINE STORAGE_DAYLREFPT2 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 9314.08 | 2328.52 |
ZONE3 BULK STORAGE_DAYLREFPT1 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 10245.50 | 2561.37 |
ZONE3 BULK STORAGE_DAYLREFPT2 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 10245.50 | 2561.37 |
ZONE1 OFFICE_DAYLREFPT1 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.29 | 1459.96 | 423.39 |
ZONE1 OFFICE_DAYLREFPT2 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.10 | 1459.96 | 146.00 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 119.03 | AstronomicalClock | - | 42.04 | 42.04 | 0.94 | |
EXTERIOR_LIGHTS_B | 2955.82 | AstronomicalClock | - | 83.67 | 62.85 | 34.87 | |
EXTERIOR_LIGHTS_C | 694.12 | AstronomicalClock | - | 83.67 | 49.42 | 6.44 | |
Exterior Lighting Total | 3768.97 | 42.25 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 17562.21 | 14029.04 | 3533.17 | 0.80 | 4.53 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 47450.86 | 33365.07 | 14085.79 | 0.70 | 4.11 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 16841.2 | 13.49 | 13.19 | ||||
PSZ-FINE STORAGE COOLING COIL | 45959.1 | 13.08 | 12.78 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Coil:Heating:Fuel | 178543.76 | 0.85 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 25267.59 | 0.84 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 71306.30 | 0.85 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.54 | 49.80 | 4.47 | 415.71 | 92.91 | 1.00 | 3.19 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.56 | 622.50 | 0.93 | 1028.20 | 1107.16 | 1.00 | 1.42 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.58 | 622.50 | 1.92 | 2053.59 | 1070.05 | 1.00 | 1.32 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9169.47 | 11003.36 | 46.45 | 0.774 | 0.929 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 23.90 | 23.90 | 0.00865 | 29.25 | 0.01337 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 24306.73 | 29168.07 | 20.93 | 1.599 | 1.919 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 26.70 | 26.70 | 0.00944 | 30.30 | 0.01337 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 0.00 | 30.91 | 0.01343 | 30.30 | 0.01337 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 10877.55 | 13053.06 | 55.10 | 0.313 | 0.376 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00718 | -16.30 | 0.00092 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 37187.32 | 44624.78 | 32.03 | 0.902 | 1.082 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 15.56 | 15.55 | 0.00574 | -16.30 | 0.00092 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 148786.47 | 178543.77 | 55.71 | 3.729 | 4.474 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 10.00 | 10.00 | 0.00513 | -16.30 | 0.00092 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 0.93 | 0.93 | 0.38 | 0.38 | 0.9287 | 0.9287 | 0.9287 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 1.92 | 1.92 | 1.08 | 1.08 | 1.9192 | 1.9192 | 1.9192 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | 178543.761 | 178543.761 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 178543.76 | 178543.76 | 4.474329 | 10.00 | 6.98 | 0.00513252 | 43.33 | 21.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 0.0000 | 10.00 | 0.00513252 | 65.8491 | 178543.77 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 17562.210 | 14029.045 | 0.928680 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 8781.10 | 7355.33 | 0.619120 | 25.44 | 17.19 | 0.00917296 | 12.00 | 11.04 | 0.00800000 | 29.49 | 0.01336553 | 21.60 | 16.5210 | 23.90 | 0.00865361 | 45.6817 | 9162.77 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 25267.590 | 25267.590 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 25267.59 | 25267.59 | 0.928681 | 16.94 | 11.56 | 0.00648992 | 40.00 | 20.89 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 11.0140 | 21.10 | 0.00717881 | 45.0337 | 10877.55 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 47450.860 | 33365.072 | 1.919160 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 23725.43 | 17977.94 | 1.279440 | 28.38 | 19.05 | 0.01030650 | 12.00 | 11.04 | 0.00800000 | 30.30 | 0.01336696 | 21.83 | 33.1951 | 26.70 | 0.00943673 | 42.1246 | 24306.73 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 71306.303 | 71306.303 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 71306.30 | 71306.30 | 1.919158 | 8.50 | 5.69 | 0.00467039 | 40.00 | 20.89 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 22.1301 | 15.55 | 0.00573507 | 51.0696 | 37187.32 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 178543.761 | 178543.761 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 4.474329 | 5.25252856 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | Sensible | 178543.76 | 178543.76 | 1.0000 | 5.25252856 | 4.474329 | 10.00 | 6.98 | 0.00513252 | 22975.0 | 43.33 | 21.85 | 0.00800000 | 64191.6 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 178543.76 | -16.30 | 0.00092409 | -16.30 | 0.00000000 | 0.0000 | 10.00 | 0.00513252 | 10.00 | 0.00513252 | 65.8491 | 178543.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17562.210 | 14029.045 | 0.928680 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8921 | 1004.8586 | 1.1739 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.928681 | 1.09020214 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | Sensible | 8781.10 | 7355.33 | 1.0000 | 0.72680064 | 0.619120 | 25.44 | 17.19 | 0.00917296 | 48935.5 | 12.00 | 11.04 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8781.10 | 29.49 | 0.01336553 | 21.60 | 0.10228463 | 16.5210 | 23.90 | 0.00865361 | 23.90 | 0.00865361 | 45.6817 | 9162.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25267.590 | 25267.590 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.928681 | 1.09020214 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 25267.59 | 25267.59 | 1.0000 | 1.09020214 | 0.928681 | 16.94 | 11.56 | 0.00648992 | 33452.3 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25267.59 | -16.30 | 0.00092409 | -16.30 | 0.10228463 | 11.0140 | 21.05 | 0.00717881 | 21.10 | 0.00717881 | 45.0337 | 10877.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 47450.860 | 33365.072 | 1.919160 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.9993 | 1004.8586 | 1.1739 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.919158 | 2.25294805 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | Sensible | 23725.43 | 17977.94 | 1.0000 | 1.50196700 | 1.279440 | 28.38 | 19.05 | 0.01030650 | 54841.1 | 12.00 | 11.04 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23725.43 | 30.30 | 0.01336696 | 21.83 | 0.42471127 | 33.1951 | 26.70 | 0.00943673 | 26.70 | 0.00943673 | 42.1246 | 24306.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 71306.303 | 71306.303 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.919158 | 2.25294805 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | Sensible | 71306.30 | 71306.30 | 1.0000 | 2.25294805 | 1.919158 | 8.50 | 5.69 | 0.00467039 | 20298.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 71306.30 | -16.30 | 0.00092409 | -16.30 | 0.42471127 | 22.1301 | 15.55 | 0.00573507 | 15.55 | 0.00573507 | 51.0696 | 37187.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-OFFICE_OA_CONTROLLER | DifferentialDryBulb | 0.10 | 0.93 | - | |||
PSZ-FINE STORAGE_OA_CONTROLLER | DifferentialDryBulb | 0.42 | 1.92 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2755.50 | 2956.17 | 2274.50 |
ZONE2 FINE STORAGE | 3142.67 | 3220.83 | 2808.67 |
ZONE3 BULK STORAGE | 3220.67 | 3366.83 | 3008.00 |
Facility | 3257.00 | 3451.83 | 3042.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 131.33 | 2.33 | 63.50 | 2.33 |
ZONE2 FINE STORAGE | 483.50 | 4.00 | 23.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 592.33 | 6.33 | 74.17 | 2.33 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.50 | 12.75 | 1010.76 | 0.653 | 0.351 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.36 | 30.00 | 2953.02 | 0.478 | 0.326 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.42 | 69.00 | 35277.63 | 0.000 | 0.172 | 0.000 | 0.136 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.50 | 12.75 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.36 | 30.00 | 2953.02 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.42 | 69.00 | 35277.63 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 9.50 | 12.75 | 1010.76 | 236.88 | 0.1023 | 0.102 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 22.36 | 30.00 | 2953.02 | 1393.41 | 0.4247 | 0.425 |
ZONE3 BULK STORAGE | 51.42 | 69.00 | 35277.63 | 3204.84 | 0.977 | ||
Total Facility | 83.28 | 111.75 | 39241.41 | 4835.13 | 0.5270 | 1.504 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
ZONE1 OFFICE | 2353781.37 | 0.00 | 2353781.37 | 2205922.67 | 4559704.04 | 3225648.14 | 5681.29 | 2338.17 | 740.55 | 0.00 |
ZONE2 FINE STORAGE | 5112127.06 | 0.00 | 5112127.06 | 8966050.58 | 14078177.64 | 13393694.68 | 5722.34 | 2754.56 | 283.10 | 6.16 |
ZONE3 BULK STORAGE | 0.00 | 29969540.56 | 29969540.56 | 44469804.90 | 74439345.46 | 30805497.77 | 7044.99 | 128.00 | 1587.01 | 5048.67 |
Total Facility | 7465908.43 | 29969540.56 | 37435448.99 | 55641778.15 | 93077227.14 | 47424840.58 | 7932.53 | 2983.67 | 2412.02 | 5048.67 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
ZONE1 OFFICE | 0.1798 | 0.0000 | 0.1798 | 0.0971 | 0.2769 | 0.1023 | 557.29 | 2338.17 | 740.55 |
ZONE2 FINE STORAGE | 0.3890 | 0.0000 | 0.3890 | 0.2664 | 0.6554 | 0.4247 | 604.33 | 2754.56 | 277.11 |
ZONE3 BULK STORAGE | 0.0000 | 1.3054 | 1.3054 | 1.6962 | 3.0016 | 0.9768 | 2732.19 | 65.17 | 838.64 |
Total Facility | 0.5688 | 1.3054 | 1.8742 | 2.0598 | 3.9339 | 1.5038 | 2808.53 | 2920.83 | 1658.66 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-OFFICE | 3243747.62 | 0.00 | 3243747.62 | 3225648.14 | 5679.17 | 0.33 | 3080.50 | 0.00 |
PSZ-FINE STORAGE | 7045047.13 | 0.00 | 7045047.13 | 13393694.68 | 5722.34 | 0.00 | 3037.66 | 6.16 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-OFFICE | 0.2478 | 0.0000 | 0.2478 | 0.1023 | 555.17 | 0.33 | 3080.50 |
PSZ-FINE STORAGE | 0.5360 | 0.0000 | 0.5360 | 0.4247 | 604.33 | 0.00 | 3031.67 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-OFFICE | 0.00 | 2762.75 | 326.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-FINE STORAGE | 0.00 | 2965.32 | 74.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-OFFICE | 0.0000 | 0.2667 | 0.5040 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-FINE STORAGE | 0.0000 | 0.6355 | 0.9254 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 50 | 50 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 451 |
Defaulted Fields | 395 |
Fields with Defaults | 1183 |
Autosized Fields | 43 |
Autosizable Fields | 97 |
Autocalculated Fields | 128 |
Autocalculatable Fields | 206 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 318.38 | 1525.96 | 12-MAR-09:20 | 28020.85 | 19-JUL-14:30 |
Electricity:Building | 212.26 | 1044.96 | 01-JAN-10:40 | 17701.90 | 27-NOV-16:00 |
Electricity:Zone:ZONE1 OFFICE | 36.89 | 520.87 | 01-JAN-00:10 | 2598.04 | 02-JAN-16:50 |
Electricity:SpaceType:GENERAL | 211.71 | 1044.96 | 01-JAN-10:40 | 17701.90 | 27-NOV-16:00 |
InteriorLights:Electricity | 75.20 | 573.43 | 17-JUL-17:20 | 7666.73 | 27-NOV-16:00 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 7.72 | 51.00 | 01-JAN-00:10 | 762.98 | 02-JAN-16:50 |
InteriorLights:Electricity:SpaceType:GENERAL | 75.20 | 573.43 | 17-JUL-17:20 | 7666.73 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity | 75.20 | 573.43 | 17-JUL-17:20 | 7666.73 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE1 OFFICE | 7.72 | 51.00 | 01-JAN-00:10 | 762.98 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 75.20 | 573.43 | 17-JUL-17:20 | 7666.73 | 27-NOV-16:00 |
Electricity:Zone:ZONE2 FINE STORAGE | 34.51 | 293.81 | 17-JUL-17:10 | 3369.94 | 27-NOV-16:00 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 34.51 | 293.81 | 17-JUL-17:10 | 3369.94 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 34.51 | 293.81 | 17-JUL-17:10 | 3369.94 | 27-NOV-16:00 |
Electricity:Zone:ZONE3 BULK STORAGE | 140.87 | 224.12 | 01-JAN-10:40 | 12426.62 | 10-AUG-16:00 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 32.97 | 224.12 | 01-JAN-10:40 | 3550.16 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 32.97 | 224.12 | 01-JAN-10:40 | 3550.16 | 27-NOV-16:00 |
InteriorEquipment:Electricity | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 29.16 | 469.88 | 01-JAN-00:10 | 1835.05 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 29.16 | 469.88 | 01-JAN-00:10 | 1835.05 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Fans:Electricity | 32.16 | 0.00 | 22-FEB-18:10 | 4185.60 | 19-JUL-15:10 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.55 | 0.00 | 01-JAN-00:10 | 2305.29 | 15-JUL-14:20 |
Ventilation (simple):Fans:Electricity | 0.55 | 0.00 | 01-JAN-00:10 | 2305.29 | 15-JUL-14:20 |
Ventilation (simple):Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.55 | 0.00 | 01-JAN-00:10 | 2305.29 | 15-JUL-14:20 |
ElectricityProduced:Facility | 105.93 | -0.00 | 11-MAY-19:20 | 21687.50 | 14-JUN-11:40 |
ElectricityProduced:Plant | 105.93 | -0.00 | 11-MAY-19:20 | 21687.50 | 14-JUN-11:40 |
Photovoltaic:ElectricityProduced | 110.92 | 0.00 | 01-JAN-00:10 | 22761.71 | 14-JUN-12:20 |
PowerConversion:ElectricityProduced | -4.99 | -1074.21 | 14-JUN-12:20 | 0.00 | 01-JAN-00:10 |
Electricity:Plant | 26.22 | 481.00 | 24-JAN-07:00 | 2703.03 | 16-FEB-13:00 |
Cogeneration:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
DCtoACInverter Ancillary:Cogeneration:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityPurchased:Facility | 227.45 | 0.00 | 01-JAN-09:40 | 25646.44 | 09-DEC-16:50 |
ElectricityPurchased:Plant | 227.45 | 0.00 | 01-JAN-09:40 | 25646.44 | 09-DEC-16:50 |
Cogeneration:ElectricityPurchased | 227.45 | 0.00 | 01-JAN-09:40 | 25646.44 | 09-DEC-16:50 |
General:Cogeneration:ElectricityPurchased | 227.45 | 0.00 | 01-JAN-09:40 | 25646.44 | 09-DEC-16:50 |
ElectricitySurplusSold:Facility | 15.01 | 0.00 | 01-JAN-00:10 | 18637.80 | 21-MAY-12:30 |
ElectricitySurplusSold:Plant | 15.01 | 0.00 | 01-JAN-00:10 | 18637.80 | 21-MAY-12:30 |
Cogeneration:ElectricitySurplusSold | 15.01 | 0.00 | 01-JAN-00:10 | 18637.80 | 21-MAY-12:30 |
General:Cogeneration:ElectricitySurplusSold | 15.01 | 0.00 | 01-JAN-00:10 | 18637.80 | 21-MAY-12:30 |
ElectricityNet:Facility | 212.44 | -18637.80 | 21-MAY-12:30 | 25646.44 | 09-DEC-16:50 |
ElectricityNet:Plant | 212.44 | -18637.80 | 21-MAY-12:30 | 25646.44 | 09-DEC-16:50 |
Cogeneration:ElectricityNet | 212.44 | -18637.80 | 21-MAY-12:30 | 25646.44 | 09-DEC-16:50 |
General:Cogeneration:ElectricityNet | 212.44 | -18637.80 | 21-MAY-12:30 | 25646.44 | 09-DEC-16:50 |
Electricity:HVAC | 37.64 | 0.00 | 22-FEB-18:10 | 10137.24 | 19-JUL-15:10 |
General:Fans:Electricity | 31.61 | 0.00 | 22-FEB-18:10 | 3229.29 | 07-FEB-08:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 6.03 | 0.00 | 01-JAN-00:10 | 8256.94 | 19-JUL-15:10 |
General:Cooling:Electricity | 6.03 | 0.00 | 01-JAN-00:10 | 8256.94 | 19-JUL-15:10 |
ExteriorLights:Electricity | 42.25 | 0.00 | 01-JAN-08:00 | 3768.97 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 42.25 | 0.00 | 01-JAN-08:00 | 3768.97 | 01-JAN-06:10 |
WaterSystems:Electricity | 26.22 | 481.00 | 24-JAN-07:00 | 2703.03 | 16-FEB-13:00 |
Water Heater:WaterSystems:Electricity | 26.22 | 481.00 | 24-JAN-07:00 | 2703.03 | 16-FEB-13:00 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 941.67 | 0.00 | 22-FEB-18:10 | 295838.25 | 12-JAN-09:00 |
NaturalGas:HVAC | 941.67 | 0.00 | 22-FEB-18:10 | 295838.25 | 12-JAN-09:00 |
Heating:NaturalGas | 941.67 | 0.00 | 22-FEB-18:10 | 295838.25 | 12-JAN-09:00 |
General:Heating:NaturalGas | 941.67 | 0.00 | 22-FEB-18:10 | 295838.25 | 12-JAN-09:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1573.11 | 0.00 | 22-FEB-18:10 | 482027.45 | 13-FEB-06:10 |
EnergyTransfer:Building | 775.62 | 0.00 | 22-FEB-18:10 | 241875.87 | 13-FEB-06:10 |
EnergyTransfer:Zone:ZONE1 OFFICE | 59.50 | 0.00 | 01-JAN-00:40 | 24871.94 | 06-FEB-07:10 |
Heating:EnergyTransfer | 741.13 | 0.00 | 22-FEB-18:10 | 241875.87 | 13-FEB-06:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 45.53 | 0.00 | 01-JAN-00:40 | 24871.94 | 06-FEB-07:10 |
General:Heating:EnergyTransfer | 741.13 | 0.00 | 22-FEB-18:10 | 241875.87 | 13-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 45.53 | 0.00 | 01-JAN-00:40 | 24871.94 | 06-FEB-07:10 |
Cooling:EnergyTransfer | 34.49 | 0.00 | 01-JAN-00:10 | 22421.12 | 19-JUL-15:10 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 13.98 | 0.00 | 01-JAN-00:10 | 7838.20 | 21-JUL-05:10 |
General:Cooling:EnergyTransfer | 34.49 | 0.00 | 01-JAN-00:10 | 22421.12 | 19-JUL-15:10 |
General:Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 13.98 | 0.00 | 01-JAN-00:10 | 7838.20 | 21-JUL-05:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 167.76 | 0.00 | 01-JAN-00:40 | 54284.38 | 13-FEB-06:10 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 147.25 | 0.00 | 01-JAN-00:40 | 54284.38 | 13-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 147.25 | 0.00 | 01-JAN-00:40 | 54284.38 | 13-FEB-06:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 20.52 | 0.00 | 01-JAN-00:10 | 15094.01 | 03-AUG-17:50 |
General:Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 20.52 | 0.00 | 01-JAN-00:10 | 15094.01 | 03-AUG-17:50 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 548.35 | 0.00 | 06-JAN-11:00 | 179162.35 | 06-FEB-10:00 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 548.35 | 0.00 | 06-JAN-11:00 | 179162.35 | 06-FEB-10:00 |
General:Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 548.35 | 0.00 | 06-JAN-11:00 | 179162.35 | 06-FEB-10:00 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 797.49 | 0.00 | 22-FEB-18:10 | 247310.69 | 12-JAN-09:00 |
HeatingCoils:EnergyTransfer | 767.59 | 0.00 | 22-FEB-18:10 | 247310.69 | 12-JAN-09:00 |
CoolingCoils:EnergyTransfer | 29.90 | 0.00 | 01-JAN-00:10 | 38997.00 | 19-JUL-15:10 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 45.528 | -13.976 | 0.000 | 0.000 | 10.138 | 7.721 | 29.165 | 10.268 | 0.000 | 0.393 | 0.000 | 0.000 | -7.640 | 0.000 | -32.792 | -48.804 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 147.247 | -20.515 | 0.000 | 0.000 | 26.803 | 34.505 | 0.000 | 29.358 | 0.000 | 0.618 | 0.002 | 0.000 | -13.375 | 0.000 | -113.343 | -91.298 |
ZONE3 BULK STORAGE | 548.352 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 65.719 | 32.973 | 107.344 | 406.944 | 0.000 | 9.266 | 0.000 | 0.000 | -161.630 | 0.000 | -603.865 | -405.103 |
Total Facility | 548.352 | 0.000 | 192.775 | -34.491 | 0.000 | 0.000 | 102.659 | 75.200 | 136.508 | 446.570 | 0.000 | 10.277 | 0.002 | 0.000 | -182.645 | 0.000 | -750.000 | -545.206 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 02-AUG-05:03 | 0.00 | 0.00 | 0.00 | -19760.99 | 0.00 | 0.00 | 92.30 | 51.00 | 550.52 | 0.00 | 0.00 | 0.00 | 20140.51 | 0.00 | -474.96 | 0.00 | -598.37 | 0.00 |
ZONE2 FINE STORAGE | 18-JUL-17:10 | 0.00 | 0.00 | 0.00 | -36280.26 | 0.00 | 0.00 | 0.00 | 351.09 | 0.00 | 2345.91 | 0.00 | 372.53 | 33210.73 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 18-JUL-17:10 | 0.00 | 0.00 | 0.00 | -36280.26 | 0.00 | 0.00 | 0.00 | 739.01 | 2519.91 | 90807.56 | 0.00 | 571.56 | 0.00 | 0.00 | 0.00 | 0.00 | -2683.81 | -55673.97 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 17-FEB-06:32 | 0.00 | 0.00 | 26697.95 | 0.00 | 0.00 | 0.00 | 137.05 | 227.91 | 550.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -497.19 | 0.00 | -1785.52 | -25330.71 |
ZONE2 FINE STORAGE | 28-DEC-20:42 | 0.00 | 0.00 | 74320.95 | 0.00 | 0.00 | 0.00 | 0.00 | 299.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1258.07 | 0.00 | -16342.54 | -57020.31 |
ZONE3 BULK STORAGE | 06-FEB-10:00 | 179163.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8319.38 | 1905.05 | 8200.12 | 413.22 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -159000.47 | -39000.82 |
Total Facility | 13-FEB-06:01 | 164898.07 | 0.00 | 97912.72 | 0.00 | 0.00 | 0.00 | 1449.04 | 799.21 | 2600.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18354.45 | 0.00 | -155519.56 | -93785.57 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9287 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 0.9287 | 0.1101 | 1.0000 | Not calculated | 0.1023 | 0.1101 | ||
PSZ-FINE STORAGE | 1.9192 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 1.9192 | 0.2213 | 1.0000 | Not calculated | 0.4247 | 0.2213 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9287 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 0.9287 | 1.0000 | 1.0000 | Not calculated | 0.1023 | 0.1101 | ||
PSZ-FINE STORAGE | 1.9192 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 1.9192 | 1.0000 | 1.0000 | Not calculated | 0.4247 | 0.2213 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 12.7487 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 30.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 12.75 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.000000 | 30.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9287 | 0.9287 | 0.9287 | No | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9192 | 1.9192 | 1.9192 | No | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9287 | 0.9287 | 0.9287 | 0.9287 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9192 | 1.9192 | 1.9192 | 1.9192 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9287 | 0.9287 | 0.9287 | No | 0.1023 | 0.2722 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9192 | 1.9192 | 1.9192 | No | 0.4247 | 0.3925 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9287 | 0.9287 | 0.9287 | 0.9287 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9192 | 1.9192 | 1.9192 | 1.9192 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 69.73 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 69.73 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 74.17 |
Number of hours cooling loads not met | 2.33 |
Number of hours not met | 76.50 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 941.67 | 295838.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 6.03 | 8256.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 75.20 | 7666.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 42.25 | 3768.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 136.51 | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.55 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 31.61 | 3229.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 26.22 | 2703.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- DCtoACInverter Ancillary | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 136.51 | 318.38 |
Natural Gas | 0.00 | 941.67 |
Additional | 0.00 | 0.00 |
Total | 136.51 | 1260.05 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 110.92 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 15.55 |
Space Heating | 0.00 |
Space Cooling | 1.25 |
Fans (All) | 6.65 |
Service Water Heating | 5.42 |
Receptacle Equipment | 28.23 |
Miscellaneous (All) | 65.85 |
Subtotal | 65.85 |
Natural Gas [MJ/m2] | |
Space Heating | 194.76 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 194.76 |
Subtotal | 194.76 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 5.97 |
Space Heating | 74.73 |
Space Cooling | 0.48 |
Fans (All) | 2.55 |
Service Water Heating | 2.08 |
Receptacle Equipment | 10.83 |
Miscellaneous | 3.35 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
PV_SCH | 8760. | 8760. |
LTG_SCH_OFFICE | 2328. | 8760. |
LTG_SCH_BULK_STORAGE | 1414. | 8760. |
LTG_SCH_FINE_STORAGE | 1414. | 8760. |
OFFICE_PLUG_SCH | 4298. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
BLDG_OCC_SCH | 2861. | 3744. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1121. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6570. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | ZONE3 BULK STORAGE HEATING SP | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 8514.17 | 245.83 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 8236.83 | 523.17 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7703.33 | 1041.67 | 15.00 | 0.00 | 0.00 |
Min | 7703.33 | 245.83 | 0.00 | 0.00 | 0.00 |
Max | 8514.17 | 1041.67 | 15.00 | 0.00 | 0.00 |
Average | 8151.44 | 603.56 | 5.00 | 0.00 | 0.00 |
Sum | 24454.33 | 1810.67 | 15.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 33027.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 74078.50 | 8640.50 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 160563.67 | 29866.67 | 762.67 | 0.00 | 0.00 |
Min | 33027.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 160563.67 | 29866.67 | 762.67 | 0.00 | 0.00 |
Average | 89223.06 | 12835.72 | 254.22 | 0.00 | 0.00 |
Sum | 267669.17 | 38507.17 | 762.67 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 7852.83 | 907.17 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 7498.33 | 1261.67 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7286.67 | 1473.33 | 0.00 | 0.00 | 0.00 |
Min | 7286.67 | 907.17 | 0.00 | 0.00 | 0.00 |
Max | 7852.83 | 1473.33 | 0.00 | 0.00 | 0.00 |
Average | 7545.94 | 1214.06 | 0.00 | 0.00 | 0.00 |
Sum | 22637.83 | 3642.17 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 31433.17 | 1593.83 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 68293.00 | 14426.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 153386.50 | 37806.50 | 0.00 | 0.00 | 0.00 |
Min | 31433.17 | 1593.83 | 0.00 | 0.00 | 0.00 |
Max | 153386.50 | 37806.50 | 0.00 | 0.00 | 0.00 |
Average | 84370.89 | 17942.11 | 0.00 | 0.00 | 0.00 |
Sum | 253112.67 | 53826.33 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:17
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 8760.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 8760.00 | 0.00 |
Average | 0.00 | 2920.00 | 5840.00 | 0.00 |
Sum | 0.00 | 8760.00 | 17520.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 33027.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 82719.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 191193.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 191193.00 | 82719.00 | 0.00 |
Average | 0.00 | 63731.00 | 38582.00 | 0.00 |
Sum | 0.00 | 191193.00 | 115746.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2022
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -1.0 | -1.6 | 0.496984E+09 | 603.25 | 23-JAN-08:09 | -6.2 | -8.2 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -3.3 | -4.7 | 0.457151E+09 | 603.25 | 25-FEB-08:09 | -8.2 | -9.2 |
March | 693931.69 | 126.67 | 16-MAR-08:40 | 11.67 | 10.61 | 0.542437E+09 | 768.97 | 15-MAR-15:30 | 11.67 | 10.61 |
April | 437548.49 | 84.34 | 24-APR-13:30 | 11.95 | 6.38 | 0.502412E+09 | 708.78 | 08-APR-14:50 | 11.95 | 6.38 |
May | 0.148755E+09 | 2433.46 | 27-MAY-16:00 | 21.70 | 12.01 | 0.578815E+09 | 768.97 | 23-MAY-12:09 | 21.70 | 12.01 |
June | 0.249189E+10 | 14778.86 | 28-JUN-05:03 | 17.20 | 15.14 | 0.654275E+09 | 769.02 | 28-JUN-10:00 | 22.20 | 18.13 |
July | 0.465739E+10 | 19271.58 | 12-JUL-05:03 | 12.48 | 10.81 | 0.634725E+09 | 769.03 | 22-JUL-14:00 | 20.60 | 19.79 |
August | 0.465121E+10 | 19765.28 | 02-AUG-05:03 | 11.60 | 10.70 | 0.685306E+09 | 769.02 | 07-AUG-07:40 | 21.50 | 19.03 |
September | 0.195187E+10 | 10713.40 | 16-SEP-05:05 | 21.20 | 19.23 | 0.625696E+09 | 769.01 | 15-SEP-13:09 | 21.20 | 19.23 |
October | 74223657.52 | 790.74 | 14-OCT-11:00 | 6.10 | 5.81 | 0.523050E+09 | 768.97 | 11-OCT-14:50 | 6.10 | 5.81 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 6.53 | 4.43 | 0.478278E+09 | 656.48 | 04-NOV-15:09 | 18.30 | 13.69 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 4.95 | 3.07 | 0.497003E+09 | 603.25 | 30-DEC-08:09 | -1.5 | -2.5 |
Annual Sum or Average | 0.139765E+11 | 0.667613E+10 | ||||||||
Minimum of Months | 0.00 | 0.00 | -3.3 | -4.7 | 0.457151E+09 | 603.25 | -8.2 | -9.2 | ||
Maximum of Months | 0.465739E+10 | 19765.28 | 21.70 | 19.23 | 0.685306E+09 | 769.03 | 22.20 | 19.79 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4961.82 | 8.27 | 11-JAN-16:00 | 11.70 | 10.14 | 0.649214E+09 | 787.42 | 09-JAN-13:09 | 11.70 | 10.14 |
February | 31114455.71 | 1859.33 | 18-FEB-14:40 | 2.80 | 0.63 | 0.597217E+09 | 787.42 | 04-FEB-13:09 | 2.80 | 0.63 |
March | 0.644053E+09 | 4194.03 | 28-MAR-12:30 | 5.55 | 1.52 | 0.747625E+09 | 1466.70 | 15-MAR-14:20 | 5.55 | 1.52 |
April | 0.140116E+10 | 4674.17 | 10-APR-09:10 | 4.68 | 3.34 | 0.738358E+09 | 1294.38 | 08-APR-14:09 | 4.68 | 3.34 |
May | 0.135657E+10 | 4000.70 | 08-MAY-07:10 | 5.87 | 1.00 | 0.108322E+10 | 1827.83 | 27-MAY-15:09 | 21.70 | 12.15 |
June | 0.221857E+10 | 18504.33 | 27-JUN-17:23 | 26.15 | 22.42 | 0.162858E+10 | 2246.84 | 20-JUN-15:20 | 26.15 | 22.42 |
July | 0.550841E+10 | 36286.11 | 18-JUL-17:10 | 28.03 | 19.76 | 0.181671E+10 | 2246.91 | 21-JUL-15:30 | 30.00 | 22.23 |
August | 0.489089E+10 | 32560.60 | 10-AUG-17:10 | 28.12 | 19.57 | 0.191212E+10 | 2246.91 | 10-AUG-14:09 | 28.12 | 19.57 |
September | 0.160105E+10 | 5586.62 | 06-SEP-07:05 | 7.77 | 6.54 | 0.145686E+10 | 2246.80 | 16-SEP-12:30 | 26.95 | 19.53 |
October | 0.195050E+10 | 5265.56 | 24-OCT-10:10 | 3.48 | 0.93 | 0.832806E+09 | 1492.89 | 05-OCT-15:09 | 3.48 | 0.93 |
November | 0.840746E+09 | 5863.39 | 28-NOV-13:45 | 1.60 | 0.95 | 0.649384E+09 | 1082.44 | 04-NOV-15:09 | 1.60 | 0.95 |
December | 72463919.53 | 4251.41 | 16-DEC-12:00 | 4.40 | 1.70 | 0.650263E+09 | 869.27 | 01-DEC-11:00 | 4.40 | 1.70 |
Annual Sum or Average | 0.205155E+11 | 0.127624E+11 | ||||||||
Minimum of Months | 4961.82 | 8.27 | 1.60 | 0.63 | 0.597217E+09 | 787.42 | 1.60 | 0.63 | ||
Maximum of Months | 0.550841E+10 | 36286.11 | 28.12 | 22.42 | 0.191212E+10 | 2246.91 | 30.00 | 22.42 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -1.0 | -1.6 | 0.646264E+09 | 941.43 | 11-JAN-16:30 | 11.40 | 9.99 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -3.3 | -4.7 | 0.594899E+09 | 985.21 | 22-FEB-16:00 | 11.70 | 5.56 |
March | 0.00 | 0.00 | 01-MAR-00:03 | -4.9 | -6.9 | 0.883744E+09 | 2428.49 | 15-MAR-14:20 | 25.93 | 16.12 |
April | 0.00 | 0.00 | 01-APR-00:05 | 4.10 | 3.72 | 0.109369E+10 | 2212.32 | 08-APR-14:20 | 20.20 | 13.55 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 | 6.11 | 0.228623E+10 | 4061.25 | 27-MAY-15:09 | 21.70 | 12.15 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 | 14.04 | 0.378724E+10 | 6249.25 | 27-JUN-13:30 | 28.90 | 23.32 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 | 13.50 | 0.479020E+10 | 7248.50 | 21-JUL-14:20 | 31.33 | 22.12 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.85 | 16.93 | 0.495968E+10 | 6774.01 | 10-AUG-14:30 | 30.30 | 20.01 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 | 12.90 | 0.326695E+10 | 5261.55 | 16-SEP-14:09 | 27.12 | 19.78 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 14.42 | 12.28 | 0.153511E+10 | 3142.28 | 03-OCT-14:30 | 18.90 | 12.82 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 6.53 | 4.43 | 0.784251E+09 | 1647.04 | 04-NOV-15:20 | 18.30 | 13.65 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 4.95 | 3.07 | 0.653356E+09 | 1185.59 | 01-DEC-11:39 | 14.27 | 12.08 |
Annual Sum or Average | 0.00 | 0.252816E+11 | ||||||||
Minimum of Months | 0.00 | 0.00 | -4.9 | -6.9 | 0.594899E+09 | 941.43 | 11.40 | 5.56 | ||
Maximum of Months | 0.00 | 0.00 | 18.85 | 16.93 | 0.495968E+10 | 7248.50 | 31.33 | 23.32 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.969166E+10 | 26670.16 | 18-JAN-06:32 | 2.80 |
February | 0.940757E+10 | 26698.03 | 17-FEB-06:32 | 1.10 |
March | 0.664258E+10 | 26013.77 | 06-MAR-06:11 | -11.1 |
April | 0.390681E+10 | 25872.49 | 17-APR-05:12 | -4.1 |
May | 0.113784E+10 | 25564.75 | 08-MAY-05:01 | 3.40 |
June | 81678893.64 | 5421.34 | 14-JUN-06:05 | 7.67 |
July | 17580116.04 | 1275.97 | 03-JUL-06:10 | 12.77 |
August | 31649899.67 | 1268.23 | 17-AUG-06:10 | 12.57 |
September | 0.106427E+09 | 24857.54 | 30-SEP-05:02 | 7.20 |
October | 0.182432E+10 | 25673.90 | 17-OCT-05:12 | -2.8 |
November | 0.409469E+10 | 25804.89 | 21-NOV-06:12 | 3.30 |
December | 0.858539E+10 | 26032.12 | 26-DEC-06:11 | -12.2 |
Annual Sum or Average | 0.455282E+11 | |||
Minimum of Months | 17580116.04 | 1268.23 | -12.2 | |
Maximum of Months | 0.969166E+10 | 26698.03 | 12.77 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.366734E+11 | 74239.01 | 12-JAN-01:22 | -3.3 |
February | 0.358979E+11 | 74317.61 | 07-FEB-20:02 | -5.6 |
March | 0.189778E+11 | 73378.36 | 06-MAR-05:22 | -11.1 |
April | 0.731972E+10 | 72339.30 | 16-APR-06:23 | -3.6 |
May | 0.321948E+09 | 62529.61 | 04-MAY-05:01 | 4.40 |
June | 0.137843E+09 | 2080.32 | 17-JUN-17:00 | 28.90 |
July | 53714165.02 | 803.38 | 15-JUL-07:00 | 22.80 |
August | 66642633.99 | 862.64 | 24-AUG-07:00 | 15.00 |
September | 80081280.44 | 879.17 | 28-SEP-07:00 | 12.20 |
October | 0.223121E+10 | 71982.66 | 17-OCT-05:01 | -2.8 |
November | 0.111682E+11 | 71997.23 | 25-NOV-06:01 | -1.7 |
December | 0.343189E+11 | 74320.77 | 28-DEC-20:42 | -9.4 |
Annual Sum or Average | 0.147247E+12 | |||
Minimum of Months | 53714165.02 | 803.38 | -11.1 | |
Maximum of Months | 0.366734E+11 | 74320.77 | 28.90 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.155501E+12 | 178990.41 | 12-JAN-09:00 | -11.1 |
February | 0.157546E+12 | 179162.35 | 06-FEB-10:00 | -15.0 |
March | 0.596598E+11 | 99916.03 | 05-MAR-01:00 | -7.2 |
April | 0.910995E+10 | 66181.29 | 16-APR-06:52 | -3.9 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.85 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 |
October | 50419927.26 | 9988.21 | 30-OCT-04:47 | -0.1 |
November | 0.201937E+11 | 43951.25 | 25-NOV-05:53 | -1.7 |
December | 0.146293E+12 | 153059.34 | 09-DEC-17:00 | -7.2 |
Annual Sum or Average | 0.548353E+12 | |||
Minimum of Months | 0.00 | 0.00 | -15.0 | |
Maximum of Months | 0.157546E+12 | 179162.35 | 18.85 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.704891E+09 | 762.98 | 02-JAN-16:49 | 0.244223E+10 | 1835.05 | 02-JAN-08:09 |
February | 0.599977E+09 | 748.90 | 01-FEB-08:09 | 0.222575E+10 | 1835.05 | 01-FEB-08:09 |
March | 0.675430E+09 | 733.43 | 17-MAR-07:10 | 0.253693E+10 | 1835.05 | 01-MAR-08:09 |
April | 0.617605E+09 | 722.58 | 12-APR-07:10 | 0.240164E+10 | 1835.05 | 01-APR-07:10 |
May | 0.627268E+09 | 703.15 | 11-MAY-07:10 | 0.248958E+10 | 1835.05 | 01-MAY-07:10 |
June | 0.601756E+09 | 672.82 | 19-JUN-07:10 | 0.244899E+10 | 1835.05 | 01-JUN-07:10 |
July | 0.592130E+09 | 697.72 | 11-JUL-07:30 | 0.244223E+10 | 1835.05 | 01-JUL-07:10 |
August | 0.637189E+09 | 703.53 | 24-AUG-07:10 | 0.253693E+10 | 1835.05 | 01-AUG-07:10 |
September | 0.619318E+09 | 730.89 | 26-SEP-07:10 | 0.240164E+10 | 1835.05 | 01-SEP-07:10 |
October | 0.654761E+09 | 759.97 | 28-OCT-07:10 | 0.244223E+10 | 1835.05 | 02-OCT-07:10 |
November | 0.677922E+09 | 762.98 | 06-NOV-16:00 | 0.235429E+10 | 1835.05 | 01-NOV-07:10 |
December | 0.713084E+09 | 762.98 | 01-DEC-16:40 | 0.244223E+10 | 1835.05 | 01-DEC-08:09 |
Annual Sum or Average | 0.772133E+10 | 0.291647E+11 | ||||
Minimum of Months | 0.592130E+09 | 672.82 | 0.222575E+10 | 1835.05 | ||
Maximum of Months | 0.713084E+09 | 762.98 | 0.253693E+10 | 1835.05 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.323564E+10 | 3333.42 | 06-JAN-15:00 | 0.00 | 0.00 |
February | 0.273381E+10 | 3220.52 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.305283E+10 | 3238.58 | 21-MAR-08:09 | 0.00 | 0.00 |
April | 0.271156E+10 | 3125.70 | 03-APR-08:09 | 0.00 | 0.00 |
May | 0.271656E+10 | 2972.13 | 31-MAY-08:09 | 0.00 | 0.00 |
June | 0.256158E+10 | 2987.82 | 14-JUN-08:09 | 0.00 | 0.00 |
July | 0.254678E+10 | 3008.29 | 13-JUL-08:09 | 0.00 | 0.00 |
August | 0.275506E+10 | 3065.68 | 17-AUG-08:09 | 0.00 | 0.00 |
September | 0.275669E+10 | 3145.03 | 21-SEP-08:09 | 0.00 | 0.00 |
October | 0.302381E+10 | 3312.92 | 31-OCT-08:09 | 0.00 | 0.00 |
November | 0.313823E+10 | 3369.94 | 27-NOV-15:00 | 0.00 | 0.00 |
December | 0.327260E+10 | 3341.07 | 19-DEC-15:00 | 0.00 | 0.00 |
Annual Sum or Average | 0.345051E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.254678E+10 | 2972.13 | 0.00 | 0.00 | |
Maximum of Months | 0.327260E+10 | 3369.94 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.312430E+10 | 3459.44 | 06-JAN-15:00 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.261371E+10 | 3160.28 | 01-FEB-16:00 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.285995E+10 | 2967.02 | 21-MAR-07:10 | 0.957200E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.254698E+10 | 2739.66 | 12-APR-07:10 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.256576E+10 | 2448.26 | 11-MAY-07:10 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.248670E+10 | 2308.23 | 14-JUN-07:10 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.247600E+10 | 2405.04 | 21-JUL-06:10 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.264914E+10 | 2582.51 | 28-AUG-06:10 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.262750E+10 | 2866.61 | 26-SEP-07:10 | 0.884875E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.284979E+10 | 3323.21 | 31-OCT-07:10 | 0.886351E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.300292E+10 | 3550.16 | 27-NOV-15:00 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.317063E+10 | 3472.81 | 19-DEC-15:00 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.329734E+11 | 0.107344E+12 | ||||
Minimum of Months | 0.247600E+10 | 2308.23 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.317063E+10 | 3550.16 | 0.957200E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.138726E+10 | 0.704891E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557551E+10 |
February | 0.127628E+10 | 0.599977E+09 | 0.222575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567673E+10 |
March | 0.149825E+10 | 0.675430E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9714224.96 | 0.376947E+10 |
April | 0.138726E+10 | 0.617605E+09 | 0.240164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251623E+10 |
May | 0.144276E+10 | 0.627268E+09 | 0.248958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7181978.88 | 0.139892E+10 |
June | 0.144276E+10 | 0.601756E+09 | 0.244899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71782620.96 | 0.990966E+09 |
July | 0.138726E+10 | 0.592130E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166076E+09 | 0.542570E+09 |
August | 0.149825E+10 | 0.637189E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124881E+09 | 0.738077E+09 |
September | 0.138726E+10 | 0.619318E+09 | 0.240164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9336017.46 | 0.109073E+10 |
October | 0.138726E+10 | 0.654761E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2964797.45 | 0.200565E+10 |
November | 0.133177E+10 | 0.677922E+09 | 0.235429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 707129.35 | 0.294677E+10 |
December | 0.138726E+10 | 0.713084E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554044E+10 |
Annual Sum or Average | 0.168137E+11 | 0.772133E+10 | 0.291647E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392644E+09 | 0.327921E+11 |
Minimum of Months | 0.127628E+10 | 0.592130E+09 | 0.222575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.542570E+09 |
Maximum of Months | 0.149825E+10 | 0.713084E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166076E+09 | 0.567673E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.326447E+10 | 0.323564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198804E+11 |
February | 0.300332E+10 | 0.273381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214193E+11 |
March | 0.352563E+10 | 0.305283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71338311.26 | 0.121079E+11 |
April | 0.326447E+10 | 0.271156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4083697.79 | 0.772971E+10 |
May | 0.339505E+10 | 0.271656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57887165.14 | 0.386252E+10 |
June | 0.339505E+10 | 0.256158E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68642758.67 | 0.380727E+10 |
July | 0.326447E+10 | 0.254678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172090E+09 | 0.272230E+10 |
August | 0.352563E+10 | 0.275506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138275E+09 | 0.318427E+10 |
September | 0.326447E+10 | 0.275669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1002245.62 | 0.374277E+10 |
October | 0.326447E+10 | 0.302381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45031122.89 | 0.539554E+10 |
November | 0.313390E+10 | 0.313823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59936859.07 | 0.885049E+10 |
December | 0.326447E+10 | 0.327260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206409E+11 |
Annual Sum or Average | 0.395654E+11 | 0.345051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.618287E+09 | 0.113343E+12 |
Minimum of Months | 0.300332E+10 | 0.254678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272230E+10 |
Maximum of Months | 0.352563E+10 | 0.327260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172090E+09 | 0.214193E+11 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.750829E+10 | 0.312430E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17475473.03 | 0.686449E+11 |
February | 0.690763E+10 | 0.261371E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 70042897.87 | 0.758896E+11 |
March | 0.810895E+10 | 0.285995E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153509E+10 | 0.386301E+11 |
April | 0.750829E+10 | 0.254698E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.776222E+09 | 0.211172E+11 |
May | 0.780862E+10 | 0.256576E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.477761E+09 | 0.153349E+11 |
June | 0.780862E+10 | 0.248670E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.348170E+09 | 0.187894E+11 |
July | 0.750829E+10 | 0.247600E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6747924.81 | 0.173098E+11 |
August | 0.810895E+10 | 0.264914E+10 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4474716.96 | 0.188186E+11 |
September | 0.750829E+10 | 0.262750E+10 | 0.884875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14651994.22 | 0.168962E+11 |
October | 0.750829E+10 | 0.284979E+10 | 0.886351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.923224E+09 | 0.186336E+11 |
November | 0.720796E+10 | 0.300292E+10 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189614E+10 | 0.219457E+11 |
December | 0.750829E+10 | 0.317063E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129952E+09 | 0.695597E+11 |
Annual Sum or Average | 0.910005E+11 | 0.329734E+11 | 0.107344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.619995E+10 | 0.401570E+12 |
Minimum of Months | 0.690763E+10 | 0.247600E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4474716.96 | 0.153349E+11 |
Maximum of Months | 0.810895E+10 | 0.317063E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189614E+10 | 0.758896E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1680.92 | 02-JAN-08:09 | 762.98 | 02-JAN-16:49 | 1835.05 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 13412.76 | 12-JAN-08:00 |
February | 1680.92 | 01-FEB-08:09 | 748.90 | 01-FEB-08:09 | 1835.05 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 14410.59 | 06-FEB-17:10 |
March | 1680.92 | 01-MAR-08:09 | 733.43 | 17-MAR-07:10 | 1835.05 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 490.08 | 15-MAR-12:00 | 9812.27 | 07-MAR-07:10 |
April | 1680.92 | 01-APR-07:10 | 722.58 | 12-APR-07:10 | 1835.05 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 7674.09 | 04-APR-17:00 |
May | 1680.92 | 01-MAY-07:10 | 703.15 | 11-MAY-07:10 | 1835.05 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 429.99 | 14-MAY-15:00 | 4525.37 | 08-MAY-07:00 |
June | 1680.92 | 01-JUN-07:10 | 672.82 | 19-JUN-07:10 | 1835.05 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1509.28 | 27-JUN-12:00 | 4155.19 | 13-JUN-06:10 |
July | 1680.92 | 01-JUL-07:10 | 697.72 | 11-JUL-07:30 | 1835.05 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1736.93 | 20-JUL-16:10 | 2991.78 | 06-JUL-06:10 |
August | 1680.92 | 01-AUG-07:10 | 703.53 | 24-AUG-07:10 | 1835.05 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1704.48 | 18-AUG-17:00 | 3317.80 | 03-AUG-06:10 |
September | 1680.92 | 01-SEP-07:10 | 730.89 | 26-SEP-07:10 | 1835.05 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 496.54 | 15-SEP-12:00 | 3871.24 | 29-SEP-06:10 |
October | 1680.92 | 02-OCT-07:10 | 759.97 | 28-OCT-07:10 | 1835.05 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.18 | 22-OCT-12:00 | 6290.97 | 17-OCT-07:00 |
November | 1680.92 | 01-NOV-07:10 | 762.98 | 06-NOV-16:00 | 1835.05 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.54 | 27-NOV-06:00 | 6794.00 | 17-NOV-18:00 |
December | 1680.92 | 01-DEC-08:09 | 762.98 | 01-DEC-16:40 | 1835.05 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 12712.87 | 26-DEC-07:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1680.92 | 672.82 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2991.78 | |||||
Maximum of Months | 1680.92 | 762.98 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 1736.93 | 14410.59 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 3955.50 | 02-JAN-08:09 | 3333.42 | 06-JAN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 34740.20 | 12-JAN-09:00 |
February | 3955.50 | 01-FEB-08:09 | 3220.52 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 31484.41 | 13-FEB-07:10 |
March | 3955.50 | 01-MAR-08:09 | 3238.58 | 21-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2201.28 | 14-MAR-15:10 | 16450.53 | 03-MAR-18:00 |
April | 3955.50 | 01-APR-07:10 | 3125.70 | 03-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 348.80 | 08-APR-13:00 | 15436.19 | 04-APR-17:00 |
May | 3955.50 | 01-MAY-07:10 | 2972.13 | 31-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2653.04 | 14-MAY-15:00 | 7222.09 | 11-MAY-15:10 |
June | 3955.50 | 01-JUN-07:10 | 2987.82 | 14-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1944.51 | 12-JUN-15:10 | 9085.59 | 13-JUN-16:00 |
July | 3955.50 | 01-JUL-07:10 | 3008.29 | 13-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3946.75 | 15-JUL-15:10 | 5739.66 | 06-JUL-02:00 |
August | 3955.50 | 01-AUG-07:10 | 3065.68 | 17-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2486.27 | 13-AUG-13:10 | 5515.17 | 30-AUG-18:00 |
September | 3955.50 | 01-SEP-07:10 | 3145.03 | 21-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.01 | 16-SEP-13:00 | 7074.35 | 29-SEP-06:10 |
October | 3955.50 | 02-OCT-07:10 | 3312.92 | 31-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.30 | 22-OCT-12:00 | 8163.91 | 23-OCT-15:05 |
November | 3955.50 | 01-NOV-07:10 | 3369.94 | 27-NOV-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1700.75 | 27-NOV-06:01 | 15680.48 | 17-NOV-09:00 |
December | 3955.50 | 01-DEC-08:09 | 3341.07 | 19-DEC-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 31103.50 | 09-DEC-18:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 3955.50 | 2972.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5515.17 | ||||
Maximum of Months | 3955.50 | 3369.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3946.75 | 34740.20 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 9097.65 | 02-JAN-08:09 | 3459.44 | 06-JAN-15:00 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3452.14 | 11-JAN-16:00 | 116847.18 | 12-JAN-09:00 |
February | 9097.65 | 01-FEB-08:09 | 3160.28 | 01-FEB-16:00 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7335.00 | 22-FEB-18:00 | 114965.27 | 07-FEB-11:00 |
March | 9097.65 | 01-MAR-08:09 | 2967.02 | 21-MAR-07:10 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 24211.81 | 14-MAR-14:00 | 53753.93 | 01-MAR-15:00 |
April | 9097.65 | 01-APR-07:10 | 2739.66 | 12-APR-07:10 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13466.29 | 07-APR-14:00 | 39461.08 | 16-APR-06:52 |
May | 9097.65 | 01-MAY-07:10 | 2448.26 | 11-MAY-07:10 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12649.76 | 14-MAY-15:00 | 26629.83 | 11-MAY-15:00 |
June | 9097.65 | 01-JUN-07:10 | 2308.23 | 14-JUN-07:10 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7637.11 | 12-JUN-11:00 | 37798.70 | 13-JUN-16:00 |
July | 9097.65 | 01-JUL-07:10 | 2405.04 | 21-JUL-06:10 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2626.47 | 15-JUL-13:55 | 24505.61 | 06-JUL-02:00 |
August | 9097.65 | 01-AUG-07:10 | 2582.51 | 28-AUG-06:10 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1752.56 | 13-AUG-12:55 | 23091.70 | 30-AUG-18:00 |
September | 9097.65 | 01-SEP-07:10 | 2866.61 | 26-SEP-07:10 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1803.00 | 16-SEP-12:10 | 25110.44 | 29-SEP-16:00 |
October | 9097.65 | 02-OCT-07:10 | 3323.21 | 31-OCT-07:10 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12215.06 | 22-OCT-12:00 | 27758.07 | 23-OCT-15:00 |
November | 9097.65 | 01-NOV-07:10 | 3550.16 | 27-NOV-15:00 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16498.94 | 27-NOV-06:43 | 33492.94 | 17-NOV-09:00 |
December | 9097.65 | 01-DEC-08:09 | 3472.81 | 19-DEC-15:00 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 12296.49 | 01-DEC-11:00 | 102731.44 | 09-DEC-15:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 9097.65 | 2308.23 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 1752.56 | 23091.70 | |||||
Maximum of Months | 9097.65 | 3550.16 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 24211.81 | 116847.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:03 | 0.00 | 203.98 | 1879.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 895.21 |
February | 0.00 | 01-FEB-00:03 | 0.00 | 203.98 | 1879.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1132.36 |
March | 126.67 | 16-MAR-08:40 | 1680.92 | 628.12 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 475.63 |
April | 84.34 | 24-APR-13:30 | 1680.92 | 604.77 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 462.40 |
May | 2433.46 | 27-MAY-16:00 | 1680.92 | 465.42 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.55 |
June | 14778.86 | 28-JUN-05:03 | 554.70 | 152.99 | 1651.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 480.10 |
July | 19271.58 | 12-JUL-05:03 | 739.61 | 203.98 | 2202.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 353.58 |
August | 19765.28 | 02-AUG-05:03 | 739.61 | 203.98 | 2202.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 598.37 |
September | 10713.40 | 16-SEP-05:05 | 369.80 | 101.99 | 1101.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.81 |
October | 790.74 | 14-OCT-11:00 | 1680.92 | 630.42 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.61 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 101.99 | 939.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 614.18 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 152.99 | 1409.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 789.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 101.99 | 939.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.81 | |
Maximum of Months | 19765.28 | 1680.92 | 630.42 | 2202.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1132.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8.27 | 11-JAN-16:00 | 3955.50 | 3160.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1817.14 |
February | 1859.33 | 18-FEB-14:40 | 3955.50 | 2638.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3163.55 |
March | 4194.03 | 28-MAR-12:30 | 3955.50 | 2372.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1811.47 |
April | 4674.17 | 10-APR-09:10 | 3955.50 | 2430.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1614.71 |
May | 4000.70 | 08-MAY-07:10 | 3955.50 | 2755.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4254.60 |
June | 18504.33 | 27-JUN-17:23 | 0.00 | 899.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 343.15 |
July | 36286.11 | 18-JUL-17:10 | 0.00 | 1404.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.53 | 0.00 |
August | 32560.60 | 10-AUG-17:10 | 0.00 | 1418.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 509.65 | 0.00 |
September | 5586.62 | 06-SEP-07:05 | 7911.00 | 5703.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1880.82 |
October | 5265.56 | 24-OCT-10:10 | 3955.50 | 2556.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1494.51 |
November | 5863.39 | 28-NOV-13:45 | 7911.00 | 5627.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3267.65 |
December | 4251.41 | 16-DEC-12:00 | 3955.50 | 2914.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 8.27 | 0.00 | 899.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 36286.11 | 7911.00 | 5703.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 509.65 | 4254.60 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:03 | 0.00 | 1792.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14499.60 |
February | 0.00 | 01-FEB-00:03 | 0.00 | 1792.96 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19472.97 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 1792.96 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17162.10 |
April | 0.00 | 01-APR-00:05 | 0.00 | 896.48 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4656.47 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 448.24 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2769.66 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 448.24 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2930.97 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 448.24 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9514.61 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 448.24 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6831.14 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 448.24 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8691.84 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 448.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5487.72 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 896.48 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7458.15 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 1344.72 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8944.06 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 448.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2769.66 | |
Maximum of Months | 0.00 | 0.00 | 1792.96 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19472.97 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.295223E+11 | 25438.52 | 09-JAN-16:00 | 0.254979E+12 | 295838.25 | 12-JAN-08:00 |
February | 0.261248E+11 | 21474.78 | 06-FEB-08:09 | 0.254806E+12 | 291986.92 | 06-FEB-16:00 |
March | 0.280520E+11 | 21229.91 | 06-MAR-15:00 | 0.110549E+12 | 158811.62 | 05-MAR-00:49 |
April | 0.246156E+11 | 20459.98 | 05-APR-07:10 | 0.276156E+11 | 114537.90 | 16-APR-03:49 |
May | 0.243912E+11 | 19367.86 | 24-MAY-07:10 | 0.149903E+10 | 26872.88 | 01-MAY-05:10 |
June | 0.244077E+11 | 24008.43 | 27-JUN-12:00 | 11907375.49 | 3525.35 | 14-JUN-06:10 |
July | 0.265571E+11 | 28020.85 | 19-JUL-14:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.275241E+11 | 26675.18 | 10-AUG-14:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.247491E+11 | 21092.81 | 16-SEP-14:09 | 34409666.37 | 6016.09 | 30-SEP-05:10 |
October | 0.259480E+11 | 20900.66 | 30-OCT-07:10 | 0.595644E+10 | 48105.07 | 30-OCT-05:10 |
November | 0.268683E+11 | 25102.26 | 17-NOV-16:49 | 0.477929E+11 | 94187.18 | 25-NOV-06:10 |
December | 0.296156E+11 | 25646.44 | 09-DEC-16:49 | 0.238425E+12 | 252612.25 | 09-DEC-16:00 |
Annual Sum or Average | 0.318376E+12 | 0.941670E+12 | ||||
Minimum of Months | 0.243912E+11 | 19367.86 | 0.00 | 0.00 | ||
Maximum of Months | 0.296156E+11 | 28020.85 | 0.254979E+12 | 295838.25 |
Report: EnergyConsumptionElectricityGeneratedPropaneMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportELECTRICITYPRODUCED:FACILITY [J] | ELECTRICITYPRODUCED:FACILITY {Maximum} [W] | ELECTRICITYPRODUCED:FACILITY {TIMESTAMP} | PROPANE:FACILITY [] | PROPANE:FACILITY [] | |
January | 0.381911E+10 | 12173.80 | 30-JAN-12:30 | 0.00 | 0.00 |
February | 0.543957E+10 | 15678.90 | 28-FEB-12:30 | 0.00 | 0.00 |
March | 0.874734E+10 | 18897.42 | 25-MAR-12:30 | 0.00 | 0.00 |
April | 0.108009E+11 | 20594.87 | 17-APR-12:20 | 0.00 | 0.00 |
May | 0.135503E+11 | 20823.20 | 31-MAY-12:20 | 0.00 | 0.00 |
June | 0.149728E+11 | 21687.50 | 14-JUN-11:39 | 0.00 | 0.00 |
July | 0.141622E+11 | 20402.80 | 01-JUL-12:30 | 0.00 | 0.00 |
August | 0.121867E+11 | 18527.66 | 08-AUG-12:20 | 0.00 | 0.00 |
September | 0.911158E+10 | 17274.26 | 07-SEP-12:30 | 0.00 | 0.00 |
October | 0.622261E+10 | 14018.88 | 11-OCT-11:00 | 0.00 | 0.00 |
November | 0.356667E+10 | 11086.71 | 03-NOV-11:30 | 0.00 | 0.00 |
December | 0.335481E+10 | 10287.04 | 10-DEC-12:30 | 0.00 | 0.00 |
Annual Sum or Average | 0.105935E+12 | 0.00 | 0.00 | ||
Minimum of Months | 0.335481E+10 | 10287.04 | 0.00 | 0.00 | |
Maximum of Months | 0.149728E+11 | 21687.50 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [J] | |
January | 0.706483E+10 | 0.475991E+10 | 0.112984E+11 | 0.00 | 0.410030E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.229892E+10 | 0.00 |
February | 0.594750E+10 | 0.387194E+10 | 0.103734E+11 | 0.00 | 0.382854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210342E+10 | 0.00 |
March | 0.658821E+10 | 0.369706E+10 | 0.121089E+11 | 0.00 | 0.329008E+10 | 0.00 | 0.00 | 782387.75 | 0.00 | 0.00 | 0.00 | 0.236690E+10 | 0.00 |
April | 0.587615E+10 | 0.298196E+10 | 0.112578E+11 | 0.00 | 0.228440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221530E+10 | 0.00 |
May | 0.590958E+10 | 0.260173E+10 | 0.117000E+11 | 0.00 | 0.192370E+10 | 0.00 | 0.00 | 17644185.46 | 0.00 | 0.00 | 0.00 | 0.223862E+10 | 0.00 |
June | 0.565004E+10 | 0.232003E+10 | 0.116594E+11 | 0.00 | 0.190799E+10 | 0.00 | 0.00 | 0.739884E+09 | 0.00 | 0.00 | 0.00 | 0.213042E+10 | 0.00 |
July | 0.561491E+10 | 0.245799E+10 | 0.112984E+11 | 0.00 | 0.220095E+10 | 0.00 | 0.00 | 0.287834E+10 | 0.00 | 0.00 | 0.00 | 0.210651E+10 | 0.00 |
August | 0.604139E+10 | 0.285303E+10 | 0.121016E+11 | 0.00 | 0.226251E+10 | 0.00 | 0.00 | 0.211804E+10 | 0.00 | 0.00 | 0.00 | 0.214763E+10 | 0.00 |
September | 0.600350E+10 | 0.332117E+10 | 0.112504E+11 | 0.00 | 0.183204E+10 | 0.00 | 0.00 | 0.278101E+09 | 0.00 | 0.00 | 0.00 | 0.206393E+10 | 0.00 |
October | 0.652836E+10 | 0.404305E+10 | 0.113057E+11 | 0.00 | 0.191500E+10 | 0.00 | 0.00 | 4.23 | 0.00 | 0.00 | 0.00 | 0.215587E+10 | 0.00 |
November | 0.681907E+10 | 0.444281E+10 | 0.108562E+11 | 0.00 | 0.261864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213161E+10 | 0.00 |
December | 0.715632E+10 | 0.490238E+10 | 0.112984E+11 | 0.00 | 0.399812E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226038E+10 | 0.00 |
Annual Sum or Average | 0.751998E+11 | 0.422531E+11 | 0.136508E+12 | 0.00 | 0.321623E+11 | 0.00 | 0.00 | 0.603279E+10 | 0.00 | 0.00 | 0.00 | 0.262195E+11 | 0.00 |
Minimum of Months | 0.561491E+10 | 0.232003E+10 | 0.103734E+11 | 0.00 | 0.183204E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206393E+10 | 0.00 |
Maximum of Months | 0.715632E+10 | 0.490238E+10 | 0.121089E+11 | 0.00 | 0.410030E+10 | 0.00 | 0.00 | 0.287834E+10 | 0.00 | 0.00 | 0.00 | 0.236690E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.254979E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.254806E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.110549E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.276156E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.149903E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 11907375.49 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 34409666.37 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.595644E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.477929E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.238425E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.941670E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.254979E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 7357.48 | 03-JAN-15:00 | 3768.97 | 01-JAN-06:10 | 10035.17 | 02-JAN-08:09 | 0.00 | 3197.39 | 12-JAN-08:00 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 7055.58 | 01-FEB-09:09 | 3768.97 | 01-FEB-06:10 | 10035.17 | 01-FEB-08:09 | 0.00 | 3229.29 | 07-FEB-08:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 6856.87 | 21-MAR-08:09 | 3768.97 | 01-MAR-06:10 | 10035.17 | 01-MAR-08:09 | 0.00 | 2819.24 | 01-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 6307.56 | 12-APR-07:10 | 3768.97 | 01-APR-05:10 | 10035.17 | 01-APR-07:10 | 0.00 | 2620.53 | 04-APR-16:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 5901.65 | 11-MAY-07:10 | 3768.97 | 01-MAY-05:10 | 10035.17 | 01-MAY-07:10 | 0.00 | 1941.69 | 03-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 5739.53 | 14-JUN-07:10 | 3421.91 | 01-JUN-19:49 | 10035.17 | 01-JUN-07:10 | 0.00 | 1849.63 | 20-JUN-14:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 5812.40 | 13-JUL-07:10 | 3421.91 | 01-JUL-19:00 | 10035.17 | 01-JUL-07:10 | 0.00 | 4185.60 | 19-JUL-15:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 6051.51 | 17-AUG-07:10 | 3768.97 | 02-AUG-05:10 | 10035.17 | 01-AUG-07:10 | 0.00 | 4154.93 | 09-AUG-16:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 6484.82 | 26-SEP-07:10 | 3768.97 | 01-SEP-05:10 | 10035.17 | 01-SEP-07:10 | 0.00 | 1849.63 | 01-SEP-06:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 7259.42 | 31-OCT-08:09 | 3768.97 | 01-OCT-05:10 | 10035.17 | 02-OCT-07:10 | 0.00 | 2450.14 | 30-OCT-06:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 7666.73 | 27-NOV-15:00 | 3768.97 | 01-NOV-05:10 | 10035.17 | 01-NOV-07:10 | 0.00 | 2567.15 | 17-NOV-08:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 7553.61 | 19-DEC-15:00 | 3768.97 | 01-DEC-06:10 | 10035.17 | 01-DEC-08:09 | 0.00 | 3106.88 | 09-DEC-17:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 5739.53 | 3421.91 | 10035.17 | 0.00 | 1849.63 | 0.00 | 0.00 | |||||
Maximum of Months | 7666.73 | 3768.97 | 10035.17 | 0.00 | 4185.60 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY {Maximum} [W] | COGENERATION:ELECTRICITY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 2688.72 | 31-JAN-12:30 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 2703.03 | 16-FEB-12:00 | 0.00 | 01-FEB-00:10 |
March | 112.17 | 15-MAR-15:09 | 0.00 | 0.00 | 0.00 | 2685.11 | 03-MAR-12:09 | 0.00 | 01-MAR-00:10 |
April | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 2575.77 | 01-APR-11:39 | 0.00 | 01-APR-00:10 |
May | 516.81 | 23-MAY-14:50 | 0.00 | 0.00 | 0.00 | 2368.85 | 01-MAY-11:39 | 0.00 | 01-MAY-00:10 |
June | 6229.70 | 27-JUN-12:00 | 0.00 | 0.00 | 0.00 | 2023.82 | 07-JUN-11:39 | 0.00 | 01-JUN-00:10 |
July | 8256.94 | 19-JUL-15:09 | 0.00 | 0.00 | 0.00 | 1811.00 | 01-JUL-11:00 | 0.00 | 01-JUL-00:10 |
August | 6386.41 | 10-AUG-15:09 | 0.00 | 0.00 | 0.00 | 1792.08 | 04-AUG-11:30 | 0.00 | 01-AUG-00:10 |
September | 2821.78 | 16-SEP-13:39 | 0.00 | 0.00 | 0.00 | 1804.05 | 29-SEP-11:00 | 0.00 | 01-SEP-00:10 |
October | 0.01 | 03-OCT-13:39 | 0.00 | 0.00 | 0.00 | 2051.89 | 28-OCT-11:50 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 2352.20 | 30-NOV-12:50 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2565.88 | 30-DEC-12:50 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1792.08 | 0.00 | |||
Maximum of Months | 8256.94 | 0.00 | 0.00 | 0.00 | 2703.03 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 25438.52 | 09-JAN-16:00 | 7180.87 | 10035.17 | 3768.97 | 0.00 | 2832.26 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 21474.78 | 06-FEB-08:09 | 6619.56 | 10035.17 | 0.00 | 0.00 | 3158.74 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 21229.91 | 06-MAR-15:00 | 6486.47 | 10035.17 | 0.00 | 0.00 | 2522.94 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 20459.98 | 05-APR-07:10 | 6224.82 | 10035.17 | 0.00 | 0.00 | 2544.35 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 19367.86 | 24-MAY-07:10 | 5840.17 | 10035.17 | 0.00 | 0.00 | 1849.63 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 24008.43 | 27-JUN-12:00 | 4125.59 | 10035.17 | 0.00 | 0.00 | 1849.63 | 0.00 | 0.00 | 6229.70 | 0.00 |
July | 28020.85 | 19-JUL-14:30 | 4299.08 | 10035.17 | 0.00 | 0.00 | 4154.93 | 0.00 | 0.00 | 7773.64 | 0.00 |
August | 26675.18 | 10-AUG-14:00 | 4640.25 | 10035.17 | 0.00 | 0.00 | 4154.93 | 0.00 | 0.00 | 6091.11 | 0.00 |
September | 21092.81 | 16-SEP-14:09 | 4730.35 | 10035.17 | 0.00 | 0.00 | 1849.63 | 0.00 | 0.00 | 2718.72 | 0.00 |
October | 20900.66 | 30-OCT-07:10 | 7119.20 | 10035.17 | 0.00 | 0.00 | 2106.21 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 25102.26 | 17-NOV-16:49 | 7180.87 | 10035.17 | 3768.97 | 0.00 | 2505.27 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 25646.44 | 09-DEC-16:49 | 7180.87 | 10035.17 | 3768.97 | 0.00 | 3045.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 19367.86 | 4125.59 | 10035.17 | 0.00 | 0.00 | 1849.63 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 28020.85 | 7180.87 | 10035.17 | 3768.97 | 0.00 | 4154.93 | 0.00 | 0.00 | 7773.64 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 295838.25 | 12-JAN-08:00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 291986.92 | 06-FEB-16:00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 158811.62 | 05-MAR-00:49 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 114537.90 | 16-APR-03:49 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 26872.88 | 01-MAY-05:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 3525.35 | 14-JUN-06:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 6016.09 | 30-SEP-05:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 48105.07 | 30-OCT-05:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 94187.18 | 25-NOV-06:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 252612.25 | 09-DEC-16:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 295838.25 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 27.00 | 16.42 | 9.67 | 17.13 | 0.00 | 17.13 | 0.00 | 17.13 |
February | 36.17 | 15.89 | 9.67 | 16.53 | 0.00 | 16.53 | 0.00 | 16.53 |
March | 13.50 | 17.95 | 9.00 | 18.54 | 0.00 | 18.54 | 0.00 | 18.54 |
April | 10.67 | 18.79 | 8.67 | 19.18 | 0.00 | 19.18 | 0.00 | 19.18 |
May | 3.33 | 20.17 | 3.33 | 20.17 | 0.00 | 20.17 | 0.00 | 20.17 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.52 | 0.33 | 24.52 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 24.54 | 1.33 | 24.54 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.52 | 0.50 | 24.52 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.50 | 0.17 | 24.50 |
October | 5.50 | 19.90 | 5.33 | 19.97 | 0.00 | 19.97 | 0.00 | 19.97 |
November | 9.17 | 19.19 | 8.33 | 19.39 | 0.00 | 19.39 | 0.00 | 19.39 |
December | 26.00 | 16.45 | 9.50 | 17.17 | 0.00 | 17.17 | 0.00 | 17.17 |
Annual Sum or Average | 131.33 | 17.06 | 63.50 | 17.83 | 2.33 | 17.90 | 2.33 | 17.98 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.53 | 0.00 | 16.53 |
Maximum of Months | 36.17 | 20.17 | 9.67 | 20.17 | 1.33 | 24.54 | 1.33 | 24.54 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 112.33 | 14.35 | 4.17 | 14.35 | 0.00 | 14.35 | 0.00 | 14.35 |
February | 101.50 | 14.25 | 4.00 | 14.24 | 0.00 | 14.24 | 0.00 | 14.24 |
March | 70.17 | 14.58 | 4.17 | 14.59 | 0.00 | 14.59 | 0.00 | 14.59 |
April | 33.67 | 14.80 | 2.83 | 14.81 | 0.00 | 14.81 | 0.00 | 14.81 |
May | 0.67 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.28 | 0.00 | 27.28 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.29 | 0.00 | 27.29 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6.50 | 14.93 | 0.67 | 14.93 | 0.00 | 14.93 | 0.00 | 14.93 |
November | 47.17 | 14.86 | 3.17 | 14.86 | 0.00 | 14.86 | 0.00 | 14.86 |
December | 111.50 | 14.42 | 4.00 | 14.41 | 0.00 | 14.41 | 0.00 | 14.41 |
Annual Sum or Average | 483.50 | 14.47 | 23.00 | 14.47 | 4.00 | 14.57 | 0.00 | 14.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 112.33 | 14.99 | 4.17 | 14.99 | 3.00 | 27.29 | 0.00 | 27.29 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 21.03 | 300.00 | 21.03 | 300.00 | 21.03 |
February | 276.00 | 21.02 | 276.00 | 21.02 | 276.00 | 21.02 |
March | 324.00 | 21.14 | 302.00 | 21.10 | 302.00 | 21.08 |
April | 300.00 | 21.15 | 280.67 | 21.12 | 280.67 | 21.10 |
May | 312.00 | 22.16 | 126.33 | 21.89 | 126.33 | 21.73 |
June | 199.00 | 23.53 | 115.17 | 23.66 | 51.17 | 23.69 |
July | 83.33 | 23.88 | 267.33 | 23.90 | 81.00 | 23.90 |
August | 66.33 | 23.84 | 258.17 | 23.89 | 52.33 | 23.89 |
September | 207.50 | 23.46 | 57.00 | 23.53 | 32.17 | 23.55 |
October | 300.00 | 21.54 | 192.67 | 21.36 | 192.67 | 21.29 |
November | 288.00 | 21.07 | 280.17 | 21.06 | 280.17 | 21.06 |
December | 300.00 | 21.03 | 300.00 | 21.03 | 300.00 | 21.03 |
Annual Sum or Average | 2956.17 | 21.71 | 2755.50 | 21.74 | 2274.50 | 21.62 |
Minimum of Months | 66.33 | 21.02 | 57.00 | 21.02 | 32.17 | 21.02 |
Maximum of Months | 324.00 | 23.88 | 302.00 | 23.90 | 302.00 | 23.90 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 15.54 | 300.00 | 15.54 | 300.00 | 15.54 |
February | 276.00 | 15.54 | 276.00 | 15.54 | 276.00 | 15.54 |
March | 324.00 | 15.98 | 319.67 | 15.95 | 319.67 | 15.94 |
April | 300.00 | 16.46 | 300.00 | 16.46 | 300.00 | 16.46 |
May | 312.00 | 19.53 | 197.67 | 19.04 | 197.67 | 18.83 |
June | 208.17 | 23.67 | 169.67 | 24.46 | 92.83 | 24.60 |
July | 217.33 | 26.53 | 292.17 | 26.43 | 215.33 | 26.47 |
August | 185.83 | 26.11 | 298.33 | 26.12 | 174.33 | 26.17 |
September | 209.50 | 22.66 | 125.50 | 23.29 | 69.17 | 23.33 |
October | 300.00 | 17.48 | 275.67 | 17.33 | 275.67 | 17.28 |
November | 288.00 | 15.83 | 288.00 | 15.83 | 288.00 | 15.83 |
December | 300.00 | 15.55 | 300.00 | 15.55 | 300.00 | 15.55 |
Annual Sum or Average | 3220.83 | 18.60 | 3142.67 | 18.75 | 2808.67 | 18.55 |
Minimum of Months | 185.83 | 15.54 | 125.50 | 15.54 | 69.17 | 15.54 |
Maximum of Months | 324.00 | 26.53 | 319.67 | 26.43 | 319.67 | 26.47 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 10.02 | 300.00 | 10.02 | 300.00 | 10.02 |
February | 276.00 | 10.02 | 276.00 | 10.02 | 276.00 | 10.02 |
March | 324.00 | 11.13 | 324.00 | 11.13 | 324.00 | 11.13 |
April | 300.00 | 12.88 | 300.00 | 12.88 | 300.00 | 12.88 |
May | 312.00 | 18.61 | 234.67 | 18.17 | 234.67 | 18.00 |
June | 239.83 | 24.04 | 163.17 | 24.76 | 111.67 | 25.02 |
July | 254.83 | 28.54 | 298.67 | 28.31 | 254.83 | 28.38 |
August | 257.67 | 27.94 | 314.50 | 27.75 | 252.33 | 27.84 |
September | 214.50 | 22.33 | 121.67 | 22.82 | 66.50 | 22.78 |
October | 300.00 | 15.44 | 300.00 | 15.44 | 300.00 | 15.44 |
November | 288.00 | 11.17 | 288.00 | 11.17 | 288.00 | 11.17 |
December | 300.00 | 10.06 | 300.00 | 10.06 | 300.00 | 10.06 |
Annual Sum or Average | 3366.83 | 16.32 | 3220.67 | 16.29 | 3008.00 | 16.08 |
Minimum of Months | 214.50 | 10.02 | 121.67 | 10.02 | 66.50 | 10.02 |
Maximum of Months | 324.00 | 28.54 | 324.00 | 28.31 | 324.00 | 28.38 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE2 FINE STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE3 BULK STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 3778251.32 | 782387.75 | 2.33 | 3522962.28 | 255289.03 | 0.00 | 0.06 | 15-MAR-15:10 | 0.00 | 01-MAR-00:03 | 543.34 | 15-MAR-15:10 | 503.86 | 15-MAR-15:10 | 39.48 | 15-MAR-15:10 | 112.17 | 15-MAR-15:10 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 |
May | 88783041.70 | 17644185.46 | 23.00 | 84792722.00 | 3990319.70 | 0.00 | 0.32 | 23-MAY-14:50 | 0.00 | 01-MAY-00:10 | 2660.03 | 23-MAY-14:50 | 2660.03 | 23-MAY-14:50 | 446.80 | 10-MAY-15:10 | 516.81 | 23-MAY-14:50 | 0.00 | 01-MAY-00:10 |
June | 0.253313E+10 | 0.471687E+09 | 147.64 | 0.194377E+10 | 0.589357E+09 | 0.00 | 1.00 | 21-JUN-05:03 | 0.00 | 01-JUN-00:10 | 20240.09 | 27-JUN-05:23 | 12739.01 | 26-JUN-05:03 | 10244.07 | 27-JUN-05:23 | 3606.70 | 27-JUN-05:23 | 0.00 | 01-JUN-00:10 |
July | 0.680083E+10 | 0.123799E+10 | 266.25 | 0.483010E+10 | 0.197073E+10 | 0.00 | 1.00 | 01-JUL-05:03 | 0.00 | 01-JUL-00:10 | 22277.73 | 21-JUL-05:01 | 13539.88 | 15-JUL-05:02 | 11985.60 | 21-JUL-05:04 | 3888.07 | 21-JUL-05:01 | 0.00 | 01-JUL-00:10 |
August | 0.549458E+10 | 0.101174E+10 | 250.62 | 0.441874E+10 | 0.107584E+10 | 0.00 | 1.00 | 01-AUG-05:03 | 0.00 | 01-AUG-00:10 | 21635.24 | 14-AUG-05:01 | 12446.61 | 05-AUG-05:03 | 12106.83 | 14-AUG-05:06 | 3768.94 | 14-AUG-05:01 | 0.00 | 01-AUG-00:10 |
September | 0.138122E+10 | 0.259279E+09 | 113.92 | 0.105231E+10 | 0.328910E+09 | 0.00 | 1.00 | 16-SEP-05:05 | 0.00 | 01-SEP-00:10 | 20090.17 | 16-SEP-05:05 | 10310.40 | 16-SEP-05:05 | 9779.76 | 16-SEP-05:05 | 3587.51 | 16-SEP-05:05 | 0.00 | 01-SEP-00:10 |
October | 20.79 | 4.23 | 0.17 | 19.84 | 0.96 | 0.00 | 0.00 | 03-OCT-13:40 | 0.00 | 01-OCT-00:10 | 0.03 | 03-OCT-13:40 | 0.03 | 03-OCT-13:40 | 0.00 | 03-OCT-13:40 | 0.01 | 03-OCT-13:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.163023E+11 | 0.299912E+10 | 803.93 | 0.123332E+11 | 0.396908E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.680083E+10 | 0.123799E+10 | 266.25 | 0.483010E+10 | 0.197073E+10 | 0.00 | 1.00 | 0.00 | 22277.73 | 13539.88 | 12106.83 | 3888.07 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 |
June | 0.117994E+10 | 0.268197E+09 | 44.39 | 0.764628E+09 | 0.415307E+09 | 0.00 | 1.00 | 27-JUN-17:23 | 0.00 | 01-JUN-00:10 | 58066.70 | 27-JUN-17:23 | 28379.12 | 27-JUN-17:23 | 29687.58 | 27-JUN-17:23 | 11431.13 | 27-JUN-17:23 | 0.00 | 01-JUN-00:10 |
July | 0.746153E+10 | 0.164035E+10 | 172.52 | 0.486381E+10 | 0.259772E+10 | 0.00 | 1.00 | 02-JUL-13:45 | 0.00 | 01-JUL-00:10 | 60253.56 | 21-JUL-03:45 | 40568.21 | 25-JUL-17:22 | 33969.23 | 21-JUL-03:45 | 11747.26 | 21-JUL-03:45 | 0.00 | 01-JUL-00:10 |
August | 0.487256E+10 | 0.110630E+10 | 146.06 | 0.376432E+10 | 0.110824E+10 | 0.00 | 1.00 | 02-AUG-17:45 | 0.00 | 01-AUG-00:10 | 57030.72 | 13-AUG-17:15 | 45674.73 | 03-AUG-17:25 | 26447.09 | 13-AUG-17:15 | 11424.67 | 13-AUG-17:15 | 0.00 | 01-AUG-00:10 |
September | 79691579.30 | 18821471.83 | 7.33 | 53990729.06 | 25700850.24 | 0.00 | 0.26 | 16-SEP-13:40 | 0.00 | 01-SEP-00:10 | 6049.43 | 16-SEP-13:40 | 4038.03 | 16-SEP-13:40 | 2011.40 | 16-SEP-13:40 | 1417.70 | 16-SEP-13:40 | 0.00 | 01-SEP-00:10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.135937E+11 | 0.303367E+10 | 370.30 | 0.944675E+10 | 0.414697E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.746153E+10 | 0.164035E+10 | 172.52 | 0.486381E+10 | 0.259772E+10 | 0.00 | 1.00 | 0.00 | 60253.56 | 45674.73 | 33969.23 | 11747.26 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 48.64 | 11.46 | 37.19 | 16.73 | 149.13 | 0.00 | 0.00 | 0.00 |
February | 78.82 | 20.34 | 58.48 | 41.07 | 139.37 | 0.00 | 0.00 | 0.00 |
March | 123.90 | 53.26 | 70.64 | 114.18 | 89.94 | 0.00 | 0.00 | 0.00 |
April | 150.72 | 61.69 | 89.03 | 163.36 | 59.16 | 0.00 | 0.00 | 0.00 |
May | 177.94 | 80.35 | 97.59 | 216.25 | 39.16 | 0.00 | 0.00 | 0.00 |
June | 214.98 | 101.14 | 113.84 | 273.73 | 34.74 | 0.00 | 0.00 | 0.00 |
July | 191.97 | 84.05 | 107.92 | 253.72 | 29.80 | 0.00 | 0.00 | 0.00 |
August | 173.44 | 73.56 | 99.88 | 225.40 | 38.33 | 0.00 | 0.00 | 0.00 |
September | 136.56 | 59.01 | 77.56 | 163.45 | 51.70 | 0.00 | 0.00 | 0.00 |
October | 88.49 | 31.17 | 57.32 | 89.71 | 64.21 | 0.00 | 0.00 | 0.00 |
November | 52.01 | 14.77 | 37.25 | 38.64 | 84.24 | 0.00 | 0.00 | 0.00 |
December | 45.37 | 9.83 | 35.54 | 15.94 | 142.59 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 123.77 | 50.20 | 73.58 | 134.84 | 76.56 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 45.37 | 9.83 | 35.54 | 15.94 | 29.80 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 214.98 | 101.14 | 113.84 | 273.73 | 149.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 48.64 | 11.46 | 37.19 | 16.73 | 149.13 | 0.00 | 0.00 | 0.00 |
February | 78.82 | 20.34 | 58.48 | 41.07 | 139.37 | 0.00 | 0.00 | 0.00 |
March | 123.90 | 53.26 | 70.64 | 114.18 | 89.94 | 0.00 | 0.00 | 0.00 |
April | 150.72 | 61.69 | 89.03 | 163.36 | 59.16 | 0.00 | 0.00 | 0.00 |
May | 177.94 | 80.35 | 97.59 | 216.25 | 39.16 | 0.00 | 0.00 | 0.00 |
June | 214.98 | 101.14 | 113.84 | 273.73 | 34.74 | 0.00 | 0.00 | 0.00 |
July | 191.97 | 84.05 | 107.92 | 253.72 | 29.80 | 0.00 | 0.00 | 0.00 |
August | 173.44 | 73.56 | 99.88 | 225.40 | 38.33 | 0.00 | 0.00 | 0.00 |
September | 136.56 | 59.01 | 77.56 | 163.45 | 51.70 | 0.00 | 0.00 | 0.00 |
October | 88.49 | 31.17 | 57.32 | 89.71 | 64.21 | 0.00 | 0.00 | 0.00 |
November | 52.01 | 14.77 | 37.25 | 38.64 | 84.24 | 0.00 | 0.00 | 0.00 |
December | 45.37 | 9.83 | 35.54 | 15.94 | 142.59 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 123.77 | 50.20 | 73.58 | 134.84 | 76.56 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 45.37 | 9.83 | 35.54 | 15.94 | 29.80 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 214.98 | 101.14 | 113.84 | 273.73 | 149.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.04 | 0.00 | 18.04 | 0.62 | 92.91 | 0.00 | 0.00 | 0.00 |
February | 27.48 | 0.00 | 27.48 | 3.36 | 86.10 | 0.00 | 0.00 | 0.00 |
March | 33.33 | 0.00 | 33.33 | 15.74 | 56.47 | 0.00 | 0.00 | 0.00 |
April | 42.49 | 0.20 | 42.29 | 32.07 | 34.84 | 0.00 | 0.00 | 0.00 |
May | 49.37 | 2.13 | 47.24 | 49.59 | 21.69 | 0.00 | 0.00 | 0.00 |
June | 59.35 | 5.05 | 54.30 | 67.56 | 19.03 | 0.00 | 0.00 | 0.00 |
July | 55.28 | 3.76 | 51.52 | 68.38 | 16.32 | 0.00 | 0.00 | 0.00 |
August | 47.86 | 0.92 | 46.93 | 55.69 | 21.64 | 0.00 | 0.00 | 0.00 |
September | 36.27 | 0.02 | 36.25 | 34.50 | 30.64 | 0.00 | 0.00 | 0.00 |
October | 27.10 | 0.00 | 27.10 | 18.36 | 38.58 | 0.00 | 0.00 | 0.00 |
November | 18.21 | 0.00 | 18.21 | 6.70 | 50.59 | 0.00 | 0.00 | 0.00 |
December | 16.88 | 0.00 | 16.88 | 0.69 | 87.78 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.01 | 1.01 | 35.00 | 29.59 | 46.19 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.88 | 0.00 | 16.88 | 0.62 | 16.32 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 59.35 | 5.05 | 54.30 | 68.38 | 92.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.04 | 0.00 | 18.04 | 0.62 | 92.91 | 0.00 | 0.00 | 0.00 |
February | 27.48 | 0.00 | 27.48 | 3.36 | 86.10 | 0.00 | 0.00 | 0.00 |
March | 33.33 | 0.00 | 33.33 | 15.74 | 56.47 | 0.00 | 0.00 | 0.00 |
April | 42.49 | 0.20 | 42.29 | 32.06 | 34.84 | 0.00 | 0.00 | 0.00 |
May | 49.36 | 2.13 | 47.24 | 49.59 | 21.69 | 0.00 | 0.00 | 0.00 |
June | 59.35 | 5.05 | 54.30 | 67.56 | 19.03 | 0.00 | 0.00 | 0.00 |
July | 55.27 | 3.76 | 51.51 | 68.37 | 16.32 | 0.00 | 0.00 | 0.00 |
August | 47.85 | 0.92 | 46.93 | 55.69 | 21.64 | 0.00 | 0.00 | 0.00 |
September | 36.27 | 0.02 | 36.25 | 34.49 | 30.64 | 0.00 | 0.00 | 0.00 |
October | 27.10 | 0.00 | 27.10 | 18.35 | 38.58 | 0.00 | 0.00 | 0.00 |
November | 18.21 | 0.00 | 18.21 | 6.70 | 50.59 | 0.00 | 0.00 | 0.00 |
December | 16.88 | 0.00 | 16.88 | 0.69 | 87.78 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.01 | 1.01 | 35.00 | 29.59 | 46.19 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.88 | 0.00 | 16.88 | 0.62 | 16.32 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 59.35 | 5.05 | 54.30 | 68.37 | 92.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.76 | 6.00 | 15.76 | 10.75 | 53.56 | 0.00 | 0.00 | 0.00 |
February | 35.04 | 9.87 | 25.17 | 24.40 | 51.17 | 0.00 | 0.00 | 0.00 |
March | 55.26 | 28.53 | 26.73 | 55.49 | 35.75 | 1.33 | 0.00 | 0.00 |
April | 73.46 | 39.25 | 34.21 | 82.91 | 24.11 | 0.00 | 0.00 | 0.00 |
May | 94.91 | 59.00 | 35.91 | 113.65 | 17.74 | 0.00 | 0.00 | 0.00 |
June | 109.91 | 69.53 | 40.38 | 133.57 | 17.21 | 0.00 | 0.00 | 0.00 |
July | 102.18 | 62.73 | 39.45 | 126.23 | 15.58 | 0.00 | 0.00 | 0.00 |
August | 86.49 | 48.47 | 38.02 | 105.28 | 18.68 | 0.00 | 0.00 | 0.00 |
September | 63.40 | 34.41 | 28.98 | 73.91 | 23.22 | 0.00 | 0.00 | 0.00 |
October | 38.91 | 16.43 | 22.48 | 41.54 | 25.48 | 0.00 | 0.00 | 0.00 |
November | 22.15 | 6.38 | 15.77 | 18.65 | 31.66 | 0.00 | 0.00 | 0.00 |
December | 19.23 | 3.70 | 15.52 | 8.88 | 50.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 60.36 | 32.15 | 28.21 | 66.50 | 30.29 | 1.33 | 0.00 | 0.00 |
Minimum of Months | 19.23 | 3.70 | 15.52 | 8.88 | 15.58 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 109.91 | 69.53 | 40.38 | 133.57 | 53.56 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 31.15 | 9.30 | 21.85 | 24.02 | 53.84 | 3.83 | 0.00 | 0.00 |
February | 49.35 | 14.46 | 34.89 | 45.43 | 52.38 | 0.00 | 0.00 | 0.00 |
March | 76.95 | 39.90 | 37.04 | 90.18 | 35.07 | 30.00 | 0.00 | 0.00 |
April | 101.30 | 53.88 | 47.42 | 127.93 | 23.33 | 5.17 | 0.00 | 0.00 |
May | 129.78 | 80.00 | 49.78 | 166.29 | 21.72 | 5.67 | 0.00 | 0.00 |
June | 150.14 | 94.17 | 55.97 | 193.04 | 22.77 | 0.00 | 0.00 | 0.00 |
July | 139.64 | 84.96 | 54.68 | 178.85 | 23.50 | 0.00 | 0.00 | 0.00 |
August | 118.75 | 66.06 | 52.69 | 149.79 | 27.67 | 0.00 | 0.00 | 0.00 |
September | 87.85 | 47.67 | 40.17 | 108.66 | 30.28 | 3.33 | 0.00 | 0.00 |
October | 54.80 | 23.63 | 31.16 | 65.07 | 28.29 | 2.17 | 0.00 | 0.00 |
November | 31.54 | 9.67 | 21.86 | 34.86 | 27.94 | 13.50 | 0.00 | 0.00 |
December | 27.39 | 5.88 | 21.52 | 20.68 | 49.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 83.39 | 44.30 | 39.10 | 100.68 | 32.95 | 63.67 | 0.00 | 0.00 |
Minimum of Months | 27.39 | 5.88 | 21.52 | 20.68 | 21.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 150.14 | 94.17 | 55.97 | 193.04 | 53.84 | 30.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130284E+09 | 30683353.24 | 99600406.33 | 44810316.27 | 0.399437E+09 |
February | 0.190674E+09 | 49209118.49 | 0.141465E+09 | 99350692.56 | 0.337165E+09 |
March | 0.331864E+09 | 0.142661E+09 | 0.189203E+09 | 0.305829E+09 | 0.240908E+09 |
April | 0.390678E+09 | 0.159901E+09 | 0.230777E+09 | 0.423433E+09 | 0.153333E+09 |
May | 0.476586E+09 | 0.215199E+09 | 0.261387E+09 | 0.579199E+09 | 0.104893E+09 |
June | 0.557216E+09 | 0.262149E+09 | 0.295067E+09 | 0.709506E+09 | 90053344.00 |
July | 0.514172E+09 | 0.225114E+09 | 0.289059E+09 | 0.679554E+09 | 79807734.92 |
August | 0.464533E+09 | 0.197011E+09 | 0.267523E+09 | 0.603699E+09 | 0.102656E+09 |
September | 0.353973E+09 | 0.152944E+09 | 0.201029E+09 | 0.423661E+09 | 0.134019E+09 |
October | 0.237019E+09 | 83490516.42 | 0.153529E+09 | 0.240271E+09 | 0.171986E+09 |
November | 0.134816E+09 | 38272447.35 | 96543168.19 | 0.100148E+09 | 0.218347E+09 |
December | 0.121529E+09 | 26332323.18 | 95196182.19 | 42704529.51 | 0.381913E+09 |
Annual Sum or Average | 0.390334E+10 | 0.158297E+10 | 0.232038E+10 | 0.425217E+10 | 0.241452E+10 |
Minimum of Months | 0.121529E+09 | 26332323.18 | 95196182.19 | 42704529.51 | 79807734.92 |
Maximum of Months | 0.557216E+09 | 0.262149E+09 | 0.295067E+09 | 0.709506E+09 | 0.399437E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130284E+09 | 30683353.24 | 99600406.33 | 44810316.27 | 0.399437E+09 |
February | 0.190674E+09 | 49209118.49 | 0.141465E+09 | 99350692.56 | 0.337165E+09 |
March | 0.331864E+09 | 0.142661E+09 | 0.189203E+09 | 0.305829E+09 | 0.240908E+09 |
April | 0.390678E+09 | 0.159901E+09 | 0.230777E+09 | 0.423433E+09 | 0.153333E+09 |
May | 0.476586E+09 | 0.215199E+09 | 0.261387E+09 | 0.579199E+09 | 0.104893E+09 |
June | 0.557216E+09 | 0.262149E+09 | 0.295067E+09 | 0.709506E+09 | 90053344.00 |
July | 0.514172E+09 | 0.225114E+09 | 0.289059E+09 | 0.679554E+09 | 79807734.92 |
August | 0.464533E+09 | 0.197011E+09 | 0.267523E+09 | 0.603699E+09 | 0.102656E+09 |
September | 0.353973E+09 | 0.152944E+09 | 0.201029E+09 | 0.423661E+09 | 0.134019E+09 |
October | 0.237019E+09 | 83490516.42 | 0.153529E+09 | 0.240271E+09 | 0.171986E+09 |
November | 0.134816E+09 | 38272447.35 | 96543168.19 | 0.100148E+09 | 0.218347E+09 |
December | 0.121529E+09 | 26332323.18 | 95196182.19 | 42704529.51 | 0.381913E+09 |
Annual Sum or Average | 0.390334E+10 | 0.158297E+10 | 0.232038E+10 | 0.425217E+10 | 0.241452E+10 |
Minimum of Months | 0.121529E+09 | 26332323.18 | 95196182.19 | 42704529.51 | 79807734.92 |
Maximum of Months | 0.557216E+09 | 0.262149E+09 | 0.295067E+09 | 0.709506E+09 | 0.399437E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 48310968.44 | 0.00 | 48310968.44 | 1666097.19 | 0.248861E+09 |
February | 66484463.22 | 0.00 | 66484463.22 | 8130389.21 | 0.208292E+09 |
March | 89279842.63 | 3161.86 | 89276680.77 | 42148398.14 | 0.151244E+09 |
April | 0.110147E+09 | 531070.45 | 0.109616E+09 | 83113053.57 | 90293660.40 |
May | 0.132220E+09 | 5693218.79 | 0.126526E+09 | 0.132833E+09 | 58104979.65 |
June | 0.153838E+09 | 13080917.28 | 0.140757E+09 | 0.175119E+09 | 49330900.93 |
July | 0.148051E+09 | 10071309.72 | 0.137980E+09 | 0.183137E+09 | 43700036.08 |
August | 0.128179E+09 | 2474394.17 | 0.125704E+09 | 0.149159E+09 | 57962826.89 |
September | 94014475.17 | 41605.79 | 93972869.38 | 89411391.54 | 79420286.42 |
October | 72588039.86 | 0.00 | 72588039.86 | 49164135.54 | 0.103338E+09 |
November | 47203867.95 | 0.00 | 47203867.95 | 17377323.02 | 0.131136E+09 |
December | 45217602.17 | 0.00 | 45217602.17 | 1861343.38 | 0.235097E+09 |
Annual Sum or Average | 0.113553E+10 | 31895678.06 | 0.110364E+10 | 0.933121E+09 | 0.145678E+10 |
Minimum of Months | 45217602.17 | 0.00 | 45217602.17 | 1666097.19 | 43700036.08 |
Maximum of Months | 0.153838E+09 | 13080917.28 | 0.140757E+09 | 0.183137E+09 | 0.248861E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 48309316.15 | 0.00 | 48309316.15 | 1665732.26 | 0.248862E+09 |
February | 66482199.62 | 0.00 | 66482199.62 | 8129021.08 | 0.208293E+09 |
March | 89277061.10 | 3161.71 | 89273899.39 | 42145787.93 | 0.151244E+09 |
April | 0.110143E+09 | 531045.56 | 0.109612E+09 | 83109252.67 | 90293562.67 |
May | 0.132216E+09 | 5692951.94 | 0.126523E+09 | 0.132828E+09 | 58104592.20 |
June | 0.153834E+09 | 13080304.16 | 0.140753E+09 | 0.175113E+09 | 49330489.08 |
July | 0.148047E+09 | 10070837.66 | 0.137976E+09 | 0.183132E+09 | 43699603.55 |
August | 0.128175E+09 | 2474278.20 | 0.125701E+09 | 0.149155E+09 | 57962425.46 |
September | 94011630.57 | 41603.84 | 93970026.73 | 89408093.32 | 79419859.68 |
October | 72585680.50 | 0.00 | 72585680.50 | 49161567.05 | 0.103338E+09 |
November | 47202250.10 | 0.00 | 47202250.10 | 17376065.70 | 0.131136E+09 |
December | 45216019.88 | 0.00 | 45216019.88 | 1860979.87 | 0.235098E+09 |
Annual Sum or Average | 0.113550E+10 | 31894183.07 | 0.110360E+10 | 0.933084E+09 | 0.145678E+10 |
Minimum of Months | 45216019.88 | 0.00 | 45216019.88 | 1665732.26 | 43699603.55 |
Maximum of Months | 0.153834E+09 | 13080304.16 | 0.140753E+09 | 0.183132E+09 | 0.248862E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 58288876.21 | 16068349.51 | 42220526.70 | 28787510.42 | 0.143454E+09 |
February | 84775729.40 | 23884856.41 | 60890872.99 | 59029400.69 | 0.123795E+09 |
March | 0.148005E+09 | 76422903.28 | 71582428.14 | 0.148619E+09 | 95747912.19 |
April | 0.190403E+09 | 0.101728E+09 | 88675024.37 | 0.214910E+09 | 62480208.85 |
May | 0.254220E+09 | 0.158025E+09 | 96194706.12 | 0.304397E+09 | 47517409.09 |
June | 0.284888E+09 | 0.180213E+09 | 0.104675E+09 | 0.346224E+09 | 44606810.76 |
July | 0.273674E+09 | 0.168016E+09 | 0.105658E+09 | 0.338100E+09 | 41719639.27 |
August | 0.231651E+09 | 0.129831E+09 | 0.101820E+09 | 0.281979E+09 | 50030855.13 |
September | 0.164325E+09 | 89202394.98 | 75122732.38 | 0.191568E+09 | 60175745.14 |
October | 0.104222E+09 | 44001082.56 | 60220840.51 | 0.111260E+09 | 68236643.20 |
November | 57420055.85 | 16533333.38 | 40886722.48 | 48343941.78 | 82060206.37 |
December | 51496521.76 | 9920242.59 | 41576279.17 | 23778060.91 | 0.135531E+09 |
Annual Sum or Average | 0.190337E+10 | 0.101385E+10 | 0.889523E+09 | 0.209700E+10 | 0.955354E+09 |
Minimum of Months | 51496521.76 | 9920242.59 | 40886722.48 | 23778060.91 | 41719639.27 |
Maximum of Months | 0.284888E+09 | 0.180213E+09 | 0.105658E+09 | 0.346224E+09 | 0.143454E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 83441577.79 | 24921368.85 | 58520208.93 | 64323798.55 | 0.144197E+09 |
February | 0.119381E+09 | 34982826.11 | 84398440.46 | 0.109901E+09 | 0.126710E+09 |
March | 0.206092E+09 | 0.106875E+09 | 99217583.91 | 0.241528E+09 | 93929155.65 |
April | 0.262558E+09 | 0.139649E+09 | 0.122909E+09 | 0.331606E+09 | 60477352.06 |
May | 0.347604E+09 | 0.214272E+09 | 0.133332E+09 | 0.445403E+09 | 58162045.18 |
June | 0.389165E+09 | 0.244079E+09 | 0.145085E+09 | 0.500362E+09 | 59032660.28 |
July | 0.374007E+09 | 0.227558E+09 | 0.146449E+09 | 0.479031E+09 | 62948818.80 |
August | 0.318050E+09 | 0.176922E+09 | 0.141128E+09 | 0.401195E+09 | 74097993.14 |
September | 0.227696E+09 | 0.123571E+09 | 0.104125E+09 | 0.281644E+09 | 78496923.87 |
October | 0.146768E+09 | 63298377.47 | 83469734.84 | 0.174275E+09 | 75781098.47 |
November | 81740639.21 | 25069163.78 | 56671475.44 | 90348195.86 | 72409873.66 |
December | 73373487.49 | 15746244.69 | 57627242.80 | 55400736.01 | 0.132802E+09 |
Annual Sum or Average | 0.262988E+10 | 0.139694E+10 | 0.123293E+10 | 0.317502E+10 | 0.103905E+10 |
Minimum of Months | 73373487.49 | 15746244.69 | 56671475.44 | 55400736.01 | 58162045.18 |
Maximum of Months | 0.389165E+09 | 0.244079E+09 | 0.146449E+09 | 0.500362E+09 | 0.144197E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 28.31 | 477.70 | 133.36 | 22.91 | 110.45 | 0.00 | 0.00 |
February | 81.82 | 443.90 | 212.60 | 40.68 | 171.91 | 0.00 | 0.00 |
March | 253.03 | 286.01 | 314.47 | 106.53 | 207.94 | 0.00 | 0.00 |
April | 389.46 | 186.59 | 386.44 | 123.79 | 262.65 | 0.00 | 0.00 |
May | 530.30 | 120.33 | 454.60 | 164.94 | 289.66 | 0.00 | 0.00 |
June | 679.86 | 104.83 | 548.65 | 212.37 | 336.28 | 0.00 | 0.00 |
July | 641.98 | 90.02 | 494.49 | 175.62 | 318.87 | 0.00 | 0.00 |
August | 561.36 | 119.13 | 442.59 | 148.96 | 293.63 | 0.00 | 0.00 |
September | 394.97 | 163.77 | 345.67 | 118.04 | 227.62 | 0.00 | 0.00 |
October | 214.63 | 204.10 | 231.19 | 62.34 | 168.84 | 0.00 | 0.00 |
November | 88.42 | 267.40 | 140.45 | 29.53 | 110.92 | 0.00 | 0.00 |
December | 27.47 | 454.92 | 124.51 | 19.66 | 104.85 | 0.00 | 0.00 |
Annual Sum or Average | 325.59 | 242.26 | 319.56 | 102.41 | 217.15 | 0.00 | 0.00 |
Minimum of Months | 27.47 | 90.02 | 124.51 | 19.66 | 104.85 | 0.00 | 0.00 |
Maximum of Months | 679.86 | 477.70 | 548.65 | 212.37 | 336.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 150.47 | 749.83 | 304.68 | 83.99 | 220.69 | 0.00 | 0.00 |
February | 341.61 | 716.40 | 490.60 | 138.22 | 352.38 | 0.00 | 0.00 |
March | 776.83 | 500.47 | 773.62 | 399.46 | 374.16 | 0.00 | 0.00 |
April | 1160.78 | 337.47 | 1028.41 | 549.46 | 478.95 | 0.00 | 0.00 |
May | 1591.08 | 248.37 | 1328.81 | 826.00 | 502.81 | 0.00 | 0.00 |
June | 1870.03 | 240.93 | 1538.74 | 973.37 | 565.37 | 0.00 | 0.00 |
July | 1767.25 | 218.07 | 1430.49 | 878.22 | 552.28 | 0.00 | 0.00 |
August | 1473.91 | 261.51 | 1210.84 | 678.63 | 532.21 | 0.00 | 0.00 |
September | 1034.70 | 325.02 | 887.56 | 481.80 | 405.76 | 0.00 | 0.00 |
October | 581.56 | 356.67 | 544.77 | 229.99 | 314.77 | 0.00 | 0.00 |
November | 261.12 | 443.23 | 310.14 | 89.30 | 220.84 | 0.00 | 0.00 |
December | 124.29 | 708.42 | 269.17 | 51.85 | 217.32 | 0.00 | 0.00 |
Annual Sum or Average | 930.93 | 424.12 | 844.98 | 450.08 | 394.89 | 0.00 | 0.00 |
Minimum of Months | 124.29 | 218.07 | 269.17 | 51.85 | 217.32 | 0.00 | 0.00 |
Maximum of Months | 1870.03 | 749.83 | 1538.74 | 973.37 | 565.37 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4072.47 | 14138.58 | 996.91 | 297.75 | 699.17 | 0.00 | 0.00 |
February | 7644.29 | 14768.21 | 1579.12 | 462.74 | 1116.38 | 0.00 | 0.00 |
March | 13659.56 | 7966.62 | 2462.27 | 1276.88 | 1185.40 | 0.00 | 0.00 |
April | 16883.68 | 4001.44 | 3241.46 | 1724.06 | 1517.39 | 0.00 | 0.00 |
May | 21027.09 | 2335.95 | 4152.98 | 2560.00 | 1592.97 | 0.00 | 0.00 |
June | 23342.47 | 2199.53 | 4804.50 | 3013.33 | 1791.18 | 0.00 | 0.00 |
July | 23073.93 | 2394.71 | 4468.42 | 2718.73 | 1749.69 | 0.00 | 0.00 |
August | 18514.48 | 2866.77 | 3799.88 | 2113.77 | 1686.12 | 0.00 | 0.00 |
September | 13365.41 | 2957.81 | 2811.06 | 1525.57 | 1285.49 | 0.00 | 0.00 |
October | 8231.81 | 3795.51 | 1753.50 | 756.25 | 997.25 | 0.00 | 0.00 |
November | 4796.08 | 5158.54 | 1009.14 | 309.50 | 699.65 | 0.00 | 0.00 |
December | 3534.10 | 12641.83 | 876.62 | 188.13 | 688.50 | 0.00 | 0.00 |
Annual Sum or Average | 13208.73 | 6228.41 | 2668.57 | 1417.50 | 1251.07 | 0.00 | 0.00 |
Minimum of Months | 3534.10 | 2199.53 | 876.62 | 188.13 | 688.50 | 0.00 | 0.00 |
Maximum of Months | 23342.47 | 14768.21 | 4804.50 | 3013.33 | 1791.18 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 75816859.63 | 0.127946E+10 | 0.357188E+09 | 61366706.49 | 0.295821E+09 | 0.00 | 0.00 |
February | 0.197934E+09 | 0.107389E+10 | 0.514315E+09 | 98418236.99 | 0.415896E+09 | 0.00 | 0.00 |
March | 0.677703E+09 | 0.766055E+09 | 0.842286E+09 | 0.285328E+09 | 0.556957E+09 | 0.00 | 0.00 |
April | 0.100947E+10 | 0.483636E+09 | 0.100165E+10 | 0.320863E+09 | 0.680782E+09 | 0.00 | 0.00 |
May | 0.142036E+10 | 0.322299E+09 | 0.121761E+10 | 0.441785E+09 | 0.775823E+09 | 0.00 | 0.00 |
June | 0.176220E+10 | 0.271721E+09 | 0.142210E+10 | 0.550460E+09 | 0.871644E+09 | 0.00 | 0.00 |
July | 0.171947E+10 | 0.241113E+09 | 0.132444E+10 | 0.470369E+09 | 0.854074E+09 | 0.00 | 0.00 |
August | 0.150355E+10 | 0.319080E+09 | 0.118542E+10 | 0.398970E+09 | 0.786450E+09 | 0.00 | 0.00 |
September | 0.102376E+10 | 0.424492E+09 | 0.895972E+09 | 0.305970E+09 | 0.590001E+09 | 0.00 | 0.00 |
October | 0.574871E+09 | 0.546652E+09 | 0.619212E+09 | 0.166981E+09 | 0.452231E+09 | 0.00 | 0.00 |
November | 0.229190E+09 | 0.693108E+09 | 0.364037E+09 | 76544894.70 | 0.287492E+09 | 0.00 | 0.00 |
December | 73567166.18 | 0.121846E+10 | 0.333491E+09 | 52664646.35 | 0.280826E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.102679E+11 | 0.763996E+10 | 0.100777E+11 | 0.322972E+10 | 0.684800E+10 | 0.00 | 0.00 |
Minimum of Months | 73567166.18 | 0.241113E+09 | 0.333491E+09 | 52664646.35 | 0.280826E+09 | 0.00 | 0.00 |
Maximum of Months | 0.176220E+10 | 0.127946E+10 | 0.142210E+10 | 0.550460E+09 | 0.871644E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.403025E+09 | 0.200835E+10 | 0.816044E+09 | 0.224957E+09 | 0.591087E+09 | 0.00 | 0.00 |
February | 0.826412E+09 | 0.173313E+10 | 0.118686E+10 | 0.334388E+09 | 0.852472E+09 | 0.00 | 0.00 |
March | 0.208067E+10 | 0.134047E+10 | 0.207207E+10 | 0.106992E+10 | 0.100215E+10 | 0.00 | 0.00 |
April | 0.300874E+10 | 0.874723E+09 | 0.266565E+10 | 0.142420E+10 | 0.124145E+10 | 0.00 | 0.00 |
May | 0.426155E+10 | 0.665244E+09 | 0.355907E+10 | 0.221235E+10 | 0.134673E+10 | 0.00 | 0.00 |
June | 0.484713E+10 | 0.624495E+09 | 0.398843E+10 | 0.252298E+10 | 0.146544E+10 | 0.00 | 0.00 |
July | 0.473340E+10 | 0.584075E+09 | 0.383143E+10 | 0.235222E+10 | 0.147922E+10 | 0.00 | 0.00 |
August | 0.394771E+10 | 0.700432E+09 | 0.324311E+10 | 0.181764E+10 | 0.142547E+10 | 0.00 | 0.00 |
September | 0.268195E+10 | 0.842460E+09 | 0.230055E+10 | 0.124883E+10 | 0.105172E+10 | 0.00 | 0.00 |
October | 0.155764E+10 | 0.955313E+09 | 0.145911E+10 | 0.616015E+09 | 0.843092E+09 | 0.00 | 0.00 |
November | 0.676815E+09 | 0.114884E+10 | 0.803881E+09 | 0.231467E+09 | 0.572414E+09 | 0.00 | 0.00 |
December | 0.332893E+09 | 0.189743E+10 | 0.720951E+09 | 0.138883E+09 | 0.582068E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.293579E+11 | 0.133750E+11 | 0.266472E+11 | 0.141938E+11 | 0.124533E+11 | 0.00 | 0.00 |
Minimum of Months | 0.332893E+09 | 0.584075E+09 | 0.720951E+09 | 0.138883E+09 | 0.572414E+09 | 0.00 | 0.00 |
Maximum of Months | 0.484713E+10 | 0.200835E+10 | 0.398843E+10 | 0.252298E+10 | 0.147922E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.109077E+11 | 0.378688E+11 | 0.267013E+10 | 0.797484E+09 | 0.187265E+10 | 0.00 | 0.00 |
February | 0.184931E+11 | 0.357273E+11 | 0.382020E+10 | 0.111945E+10 | 0.270075E+10 | 0.00 | 0.00 |
March | 0.365858E+11 | 0.213378E+11 | 0.659495E+10 | 0.341999E+10 | 0.317496E+10 | 0.00 | 0.00 |
April | 0.437625E+11 | 0.103717E+11 | 0.840186E+10 | 0.446877E+10 | 0.393309E+10 | 0.00 | 0.00 |
May | 0.563190E+11 | 0.625660E+10 | 0.111233E+11 | 0.685672E+10 | 0.426661E+10 | 0.00 | 0.00 |
June | 0.605037E+11 | 0.570119E+10 | 0.124533E+11 | 0.781054E+10 | 0.464273E+10 | 0.00 | 0.00 |
July | 0.618012E+11 | 0.641399E+10 | 0.119682E+11 | 0.728186E+10 | 0.468636E+10 | 0.00 | 0.00 |
August | 0.495892E+11 | 0.767836E+10 | 0.101776E+11 | 0.566151E+10 | 0.451610E+10 | 0.00 | 0.00 |
September | 0.346431E+11 | 0.766664E+10 | 0.728627E+10 | 0.395428E+10 | 0.333199E+10 | 0.00 | 0.00 |
October | 0.220481E+11 | 0.101659E+11 | 0.469658E+10 | 0.202555E+10 | 0.267103E+10 | 0.00 | 0.00 |
November | 0.124314E+11 | 0.133709E+11 | 0.261570E+10 | 0.802213E+09 | 0.181349E+10 | 0.00 | 0.00 |
December | 0.946574E+10 | 0.338599E+11 | 0.234795E+10 | 0.503880E+09 | 0.184407E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.416550E+12 | 0.196419E+12 | 0.841561E+11 | 0.447022E+11 | 0.394538E+11 | 0.00 | 0.00 |
Minimum of Months | 0.946574E+10 | 0.570119E+10 | 0.234795E+10 | 0.503880E+09 | 0.181349E+10 | 0.00 | 0.00 |
Maximum of Months | 0.618012E+11 | 0.378688E+11 | 0.124533E+11 | 0.781054E+10 | 0.468636E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -3.4 | -4.9 | -8.7 | 5.96 | -14.4 | 41.15 | 62.17 | 0.00 |
February | -4.2 | -5.4 | -8.1 | 6.66 | -15.1 | 65.72 | 71.39 | 0.00 |
March | 2.67 | 0.66 | -2.8 | 5.20 | -8.9 | 69.76 | 141.76 | 0.00 |
April | 7.47 | 4.95 | 1.92 | 5.29 | -2.7 | 89.32 | 159.79 | 0.00 |
May | 13.73 | 9.66 | 5.81 | 4.79 | 3.34 | 93.75 | 203.34 | 0.03 |
June | 18.63 | 14.47 | 11.49 | 5.10 | 8.69 | 105.42 | 236.95 | 0.00 |
July | 22.03 | 18.19 | 16.11 | 4.43 | 13.39 | 102.98 | 214.28 | 0.00 |
August | 20.69 | 16.39 | 13.72 | 4.23 | 11.88 | 99.24 | 178.64 | 0.00 |
September | 16.55 | 13.42 | 11.22 | 4.10 | 7.08 | 75.66 | 154.97 | 0.03 |
October | 9.73 | 7.36 | 4.97 | 4.79 | 0.13 | 58.70 | 104.01 | 0.00 |
November | 6.03 | 3.70 | 0.77 | 5.87 | -3.2 | 41.19 | 58.47 | 0.00 |
December | -2.2 | -3.2 | -5.3 | 6.59 | -12.0 | 40.52 | 44.30 | 0.00 |
Annual Sum or Average | 9.05 | 6.33 | 3.49 | 5.24 | -0.9 | 73.64 | 136.19 | 0.01 |
Minimum of Months | -4.2 | -5.4 | -8.7 | 4.10 | -15.1 | 40.52 | 44.30 | 0.00 |
Maximum of Months | 22.03 | 18.19 | 16.11 | 6.66 | 13.39 | 105.42 | 236.95 | 0.03 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.70 | 11-JAN-15:00 | 10.14 | 8.90 | 13.40 | 7.15 | 65.50 | 1.00 |
February | 12.80 | 22-FEB-17:00 | 6.18 | -2.2 | 14.90 | 3.48 | 0.00 | 0.00 |
March | 26.10 | 15-MAR-13:00 | 16.06 | 9.40 | 6.70 | 14.65 | 249.50 | 400.00 |
April | 21.10 | 08-APR-12:00 | 13.43 | 7.80 | 8.20 | 11.46 | 330.00 | 283.50 |
May | 26.10 | 10-MAY-13:00 | 17.84 | 13.30 | 5.20 | 13.35 | 258.50 | 457.00 |
June | 30.60 | 12-JUN-13:00 | 20.23 | 15.00 | 8.20 | 17.93 | 252.00 | 572.00 |
July | 31.70 | 21-JUL-13:00 | 21.73 | 17.20 | 5.20 | 22.47 | 330.00 | 231.00 |
August | 30.60 | 10-AUG-13:00 | 20.24 | 15.00 | 5.70 | 19.70 | 220.50 | 635.00 |
September | 27.20 | 16-SEP-13:09 | 19.53 | 15.68 | 8.80 | 17.30 | 207.00 | 564.67 |
October | 22.20 | 11-OCT-12:00 | 14.14 | 8.30 | 6.20 | 6.95 | 121.00 | 665.00 |
November | 19.40 | 05-NOV-13:00 | 13.85 | 10.00 | 12.40 | 14.84 | 133.00 | 3.50 |
December | 15.00 | 01-DEC-10:00 | 12.41 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.70 | 6.18 | -2.2 | 5.20 | 3.48 | 0.00 | 0.00 | |
Maximum of Months | 31.70 | 21.73 | 17.20 | 14.90 | 22.47 | 330.00 | 665.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -13.9 | 31-JAN-01:00 | -14.5 | -17.2 | 1.50 | -25.9 | 0.00 | 0.00 |
February | -16.7 | 07-FEB-06:00 | -17.3 | -20.6 | 6.20 | -35.1 | 0.00 | 0.00 |
March | -13.3 | 07-MAR-05:19 | -13.9 | -16.7 | 2.43 | -32.2 | 0.00 | 0.00 |
April | -4.4 | 17-APR-05:00 | -5.4 | -7.8 | 2.10 | -20.5 | 35.00 | 151.50 |
May | 1.70 | 01-MAY-04:00 | 0.96 | 0.00 | 0.00 | -14.2 | 0.00 | 0.00 |
June | 6.70 | 04-JUN-04:00 | 5.40 | 3.90 | 2.10 | -7.3 | 20.00 | 104.00 |
July | 11.70 | 03-JUL-03:00 | 11.07 | 10.60 | 2.10 | -1.2 | 0.00 | 0.00 |
August | 11.10 | 01-AUG-04:00 | 10.75 | 10.60 | 2.10 | -0.8 | 0.00 | 0.00 |
September | 6.10 | 05-SEP-05:00 | 5.59 | 5.00 | 2.10 | -6.2 | 24.50 | 41.00 |
October | -2.8 | 17-OCT-04:10 | -3.2 | -4.0 | 2.18 | -19.4 | 0.00 | 0.00 |
November | -3.9 | 24-NOV-05:00 | -4.5 | -5.6 | 2.10 | -18.1 | 0.00 | 0.00 |
December | -18.9 | 11-DEC-05:00 | -19.4 | -23.3 | 2.10 | -35.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -18.9 | -19.4 | -23.3 | 0.00 | -35.1 | 0.00 | 0.00 | |
Maximum of Months | 11.70 | 11.07 | 10.60 | 6.20 | -0.8 | 35.00 | 151.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.21 | 11-JAN-17:00 | 11.10 | 9.40 | 10.30 | 6.55 | 0.00 | 0.00 |
February | 6.89 | 01-FEB-03:00 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 |
March | 17.83 | 14-MAR-12:00 | 25.00 | 13.90 | 6.20 | 14.10 | 197.00 | 562.50 |
April | 13.78 | 08-APR-13:00 | 20.60 | 8.90 | 10.30 | 9.72 | 268.50 | 325.50 |
May | 18.19 | 10-MAY-14:00 | 26.10 | 13.90 | 5.20 | 16.85 | 273.00 | 238.00 |
June | 23.75 | 27-JUN-12:00 | 30.60 | 21.10 | 9.30 | 21.09 | 304.00 | 606.00 |
July | 24.79 | 21-JUL-01:00 | 28.90 | 23.30 | 8.80 | 27.46 | 0.00 | 0.00 |
August | 23.42 | 13-AUG-15:00 | 29.40 | 21.10 | 9.80 | 19.87 | 212.00 | 276.00 |
September | 21.17 | 15-SEP-11:00 | 26.10 | 18.90 | 3.60 | 16.30 | 204.00 | 464.50 |
October | 15.23 | 12-OCT-14:00 | 18.30 | 13.30 | 10.30 | 9.13 | 148.00 | 367.50 |
November | 13.96 | 05-NOV-14:00 | 18.30 | 11.10 | 11.30 | 14.10 | 72.00 | 6.00 |
December | 12.41 | 01-DEC-10:00 | 15.00 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.89 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 24.79 | 30.60 | 23.30 | 12.90 | 27.46 | 304.00 | 606.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 9.40 | 11-JAN-13:00 | 10.00 | 9.66 | 12.90 | 5.54 | 95.50 | 2.00 |
February | 6.70 | 01-FEB-04:10 | 7.20 | 6.89 | 3.52 | 2.22 | 0.00 | 0.00 |
March | 15.00 | 14-MAR-10:20 | 20.33 | 16.97 | 4.80 | 10.50 | 159.17 | 592.83 |
April | 11.10 | 08-APR-21:00 | 13.90 | 12.23 | 12.90 | 9.72 | 0.00 | 0.00 |
May | 15.60 | 17-MAY-12:00 | 16.70 | 15.97 | 6.70 | 13.54 | 184.00 | 0.00 |
June | 21.70 | 27-JUN-14:00 | 25.60 | 22.78 | 8.20 | 16.85 | 255.50 | 530.00 |
July | 23.30 | 20-JUL-20:00 | 25.60 | 24.03 | 4.60 | 24.16 | 0.00 | 0.00 |
August | 21.70 | 14-AUG-03:20 | 23.70 | 22.19 | 5.00 | 21.90 | 0.00 | 0.00 |
September | 20.00 | 15-SEP-18:00 | 21.70 | 20.51 | 0.00 | 19.52 | 0.00 | 0.00 |
October | 14.40 | 01-OCT-07:19 | 14.60 | 14.50 | 3.77 | 10.56 | 67.50 | 30.17 |
November | 11.70 | 05-NOV-15:00 | 12.80 | 12.14 | 7.20 | 8.74 | 28.00 | 4.50 |
December | 11.10 | 01-DEC-12:00 | 13.90 | 12.22 | 10.30 | 6.35 | 158.00 | 84.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.70 | 7.20 | 6.89 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 23.30 | 25.60 | 24.03 | 12.90 | 24.16 | 255.50 | 592.83 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 7.32 | 12.49 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 6.57 | 19.26 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 7.29 | 28.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 9.34 | 37.44 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.19 | 46.60 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 15.07 | 54.01 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.20 | 50.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.01 | 43.20 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.27 | 32.93 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.18 | 21.28 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.32 | 12.54 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 9.45 | 10.96 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.30 | 30.86 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 6.57 | 10.96 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.01 | 54.01 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.101106E+10 | -922988735.3 | 0.00 | 0.00 | 744.00 | 0.00 | -88072788.6 | 58.99 | 0.00 | 0.00 |
February | 0.939604E+09 | -860111926.2 | 0.00 | 0.00 | 672.00 | 0.00 | -79492132.4 | 58.99 | 0.00 | 0.00 |
March | 0.107847E+10 | -991504968.0 | 0.00 | 0.00 | 744.00 | 0.00 | -86968854.0 | 58.99 | 0.00 | 0.00 |
April | 0.968499E+09 | -884833472.4 | 0.00 | 0.00 | 720.00 | 0.00 | -83665963.1 | 58.99 | 0.00 | 0.00 |
May | 0.949952E+09 | -868056114.2 | 0.00 | 0.00 | 744.00 | 0.00 | -81896140.5 | 58.99 | 0.00 | 0.00 |
June | 0.884039E+09 | -811347256.3 | 0.00 | 0.00 | 720.00 | 0.00 | -72692200.0 | 58.99 | 0.00 | 0.00 |
July | 0.818062E+09 | -745934657.3 | 0.00 | 0.00 | 744.00 | 0.00 | -72127830.9 | 59.00 | 0.00 | 0.00 |
August | 0.858691E+09 | -786004255.4 | 0.00 | 0.00 | 744.00 | 0.00 | -72686963.1 | 58.99 | 0.00 | 0.00 |
September | 0.817309E+09 | -744042685.4 | 0.00 | 0.00 | 720.00 | 0.00 | -73266022.3 | 58.99 | 0.00 | 0.00 |
October | 0.867275E+09 | -783066054.3 | 0.00 | 0.00 | 744.00 | 0.00 | -84209243.3 | 58.99 | 0.00 | 0.00 |
November | 0.884817E+09 | -800546905.8 | 0.00 | 0.00 | 720.00 | 0.00 | -84269863.0 | 58.99 | 0.00 | 0.00 |
December | 0.972064E+09 | -884020240.2 | 0.00 | 0.00 | 744.00 | 0.00 | -88044218.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.110498E+11 | -0.100825E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -967392219.3 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.817309E+09 | -991504968.0 | 0.00 | 0.00 | 672.00 | 0.00 | -88072788.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.107847E+10 | -744042685.4 | 0.00 | 0.00 | 744.00 | 0.00 | -72127830.9 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE2 FINE STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.83 | 0.50 | 27-JAN-12:20 | 117.78 | 0.00 | 0.00 | 0.00 | 225.72 | 0.00 | 0.00 | 14.17 |
February | 262.50 | 0.76 | 0.50 | 05-FEB-11:30 | 165.22 | 0.00 | 0.00 | 7.50 | 210.57 | 0.00 | 0.00 | 9.33 |
March | 339.33 | 0.76 | 0.50 | 10-MAR-11:39 | 170.18 | 0.00 | 0.00 | 28.83 | 133.52 | 0.00 | 0.00 | 3.50 |
April | 371.17 | 0.74 | 0.50 | 01-APR-11:20 | 194.12 | 0.00 | 0.00 | 66.67 | 150.64 | 0.00 | 0.00 | 27.83 |
May | 332.17 | 0.72 | 0.50 | 01-MAY-10:39 | 207.77 | 0.00 | 0.00 | 81.83 | 582.03 | 0.00 | 0.00 | 55.17 |
June | 430.67 | 0.71 | 0.50 | 01-JUN-09:00 | 222.06 | 0.00 | 0.00 | 110.67 | 1120.49 | 0.00 | 0.00 | 112.50 |
July | 439.00 | 0.71 | 0.50 | 01-JUL-10:20 | 220.29 | 0.00 | 0.00 | 109.00 | 801.57 | 0.00 | 0.00 | 94.33 |
August | 406.00 | 0.71 | 0.50 | 01-AUG-09:50 | 217.18 | 0.00 | 0.00 | 105.50 | 171.39 | 0.00 | 0.00 | 51.67 |
September | 289.17 | 0.73 | 0.50 | 01-SEP-10:30 | 185.67 | 0.00 | 0.00 | 39.50 | 442.09 | 0.00 | 0.00 | 33.83 |
October | 314.33 | 0.79 | 0.50 | 01-OCT-12:30 | 148.96 | 0.00 | 0.00 | 3.17 | 213.51 | 0.00 | 0.00 | 9.17 |
November | 258.33 | 0.84 | 0.58 | 05-NOV-11:30 | 116.88 | 0.00 | 0.00 | 0.00 | 90.26 | 0.00 | 0.00 | 0.00 |
December | 230.67 | 0.83 | 0.59 | 09-DEC-12:39 | 121.11 | 0.00 | 0.00 | 0.00 | 93.23 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3928.50 | 0.75 | 181.09 | 0.00 | 0.00 | 552.67 | 394.87 | 0.00 | 0.00 | 411.50 | ||
Minimum of Months | 230.67 | 0.71 | 0.50 | 116.88 | 0.00 | 0.00 | 0.00 | 90.26 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 439.00 | 0.84 | 0.59 | 222.06 | 0.00 | 0.00 | 110.67 | 1120.49 | 0.00 | 0.00 | 112.50 |
Report: DaylightingReportMonthly
For: ZONE3 BULK STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.63 | 0.50 | 01-JAN-10:39 | 192.30 | 12.73 | 0.00 | 109.17 | 159.53 | 15.91 | 0.33 | 70.50 |
February | 262.50 | 0.59 | 0.50 | 01-FEB-10:30 | 268.55 | 14.15 | 0.00 | 170.00 | 220.81 | 17.43 | 34.17 | 139.83 |
March | 339.33 | 0.59 | 0.50 | 01-MAR-10:09 | 274.43 | 13.80 | 0.00 | 218.50 | 228.01 | 17.34 | 58.50 | 171.83 |
April | 371.17 | 0.59 | 0.50 | 01-APR-07:49 | 311.40 | 14.03 | 0.00 | 255.50 | 259.73 | 17.59 | 87.00 | 213.00 |
May | 332.17 | 0.58 | 0.50 | 01-MAY-07:40 | 1029.01 | 14.12 | 0.83 | 288.50 | 1844.44 | 19.23 | 95.33 | 245.17 |
June | 430.67 | 0.58 | 0.50 | 01-JUN-06:30 | 2012.15 | 14.28 | 0.17 | 305.33 | 2177.27 | 17.99 | 109.67 | 259.00 |
July | 439.00 | 0.58 | 0.50 | 01-JUL-07:10 | 1478.24 | 14.29 | 1.50 | 308.50 | 1803.28 | 18.55 | 110.83 | 267.33 |
August | 406.00 | 0.58 | 0.50 | 01-AUG-06:49 | 350.62 | 14.59 | 0.00 | 287.50 | 636.50 | 18.83 | 115.00 | 245.67 |
September | 289.17 | 0.59 | 0.50 | 01-SEP-07:00 | 651.22 | 15.74 | 17.67 | 231.67 | 942.15 | 18.16 | 84.50 | 189.83 |
October | 314.33 | 0.60 | 0.50 | 01-OCT-08:09 | 586.20 | 14.17 | 12.83 | 190.67 | 477.88 | 16.78 | 32.17 | 144.00 |
November | 258.33 | 0.63 | 0.50 | 01-NOV-08:00 | 725.91 | 12.29 | 0.00 | 117.50 | 462.25 | 15.41 | 0.00 | 73.33 |
December | 230.67 | 0.62 | 0.50 | 01-DEC-11:00 | 472.99 | 12.76 | 0.00 | 108.17 | 418.63 | 15.89 | 0.00 | 74.00 |
Annual Sum or Average | 3928.50 | 0.59 | 762.92 | 14.00 | 33.00 | 2591.00 | 893.85 | 17.60 | 727.50 | 2093.50 | ||
Minimum of Months | 230.67 | 0.58 | 0.50 | 192.30 | 12.29 | 0.00 | 108.17 | 159.53 | 15.41 | 0.00 | 70.50 | |
Maximum of Months | 439.00 | 0.63 | 0.50 | 2012.15 | 15.74 | 17.67 | 308.50 | 2177.27 | 19.23 | 115.00 | 267.33 |
Report: DaylightingReportMonthly
For: ZONE1 OFFICE_DAYLCTRL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.83 | 0.65 | 30-JAN-14:30 | 211.63 | 22.33 | 116.67 | 13.67 | 96.43 | 20.21 | 90.83 | 0.00 |
February | 262.50 | 0.77 | 0.61 | 06-FEB-14:39 | 293.17 | 23.40 | 164.83 | 43.33 | 139.05 | 21.48 | 153.33 | 0.67 |
March | 339.33 | 0.76 | 0.61 | 01-MAR-15:09 | 410.46 | 23.38 | 188.33 | 75.83 | 318.77 | 23.91 | 206.17 | 38.17 |
April | 371.17 | 0.75 | 0.61 | 02-APR-14:09 | 325.56 | 21.69 | 189.17 | 95.67 | 284.50 | 22.74 | 226.33 | 62.83 |
May | 332.17 | 0.72 | 0.61 | 01-MAY-13:30 | 318.72 | 21.59 | 200.67 | 102.17 | 388.81 | 22.75 | 252.17 | 76.50 |
June | 430.67 | 0.72 | 0.61 | 01-JUN-14:30 | 331.37 | 21.50 | 227.83 | 144.17 | 437.17 | 22.77 | 280.17 | 105.00 |
July | 439.00 | 0.72 | 0.61 | 01-JUL-13:00 | 318.76 | 21.41 | 231.00 | 138.33 | 395.84 | 22.61 | 289.00 | 94.50 |
August | 406.00 | 0.73 | 0.61 | 01-AUG-13:30 | 315.65 | 21.75 | 222.50 | 123.50 | 320.05 | 22.73 | 267.50 | 81.00 |
September | 289.17 | 0.73 | 0.61 | 01-SEP-14:09 | 512.93 | 24.20 | 189.33 | 92.17 | 440.73 | 24.72 | 225.67 | 56.00 |
October | 314.33 | 0.78 | 0.61 | 01-OCT-16:19 | 357.05 | 23.53 | 166.33 | 52.83 | 155.93 | 22.60 | 169.17 | 11.67 |
November | 258.33 | 0.83 | 0.63 | 03-NOV-15:20 | 203.64 | 21.45 | 104.50 | 12.17 | 96.25 | 19.79 | 87.33 | 0.00 |
December | 230.67 | 0.83 | 0.65 | 10-DEC-14:20 | 193.79 | 21.74 | 101.17 | 8.17 | 98.34 | 20.33 | 87.67 | 0.00 |
Annual Sum or Average | 3928.50 | 0.76 | 322.16 | 22.26 | 2102.33 | 902.00 | 285.10 | 22.38 | 2335.33 | 526.33 | ||
Minimum of Months | 230.67 | 0.72 | 0.61 | 193.79 | 21.41 | 101.17 | 8.17 | 96.25 | 19.79 | 87.33 | 0.00 | |
Maximum of Months | 439.00 | 0.83 | 0.65 | 512.93 | 24.20 | 231.00 | 144.17 | 440.73 | 24.72 | 289.00 | 105.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.112099E+11 | 25267.59 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.108392E+11 | 25267.59 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.748317E+10 | 25267.59 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.415307E+10 | 25267.59 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.921117E+09 | 25267.59 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 8122073.45 | 4827.55 | 14-JUN-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 24380711.08 | 25267.59 | 30-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188194E+10 | 25267.59 | 02-OCT-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.458713E+10 | 25267.59 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.995674E+10 | 25267.59 | 01-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.510648E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.112099E+11 | 25267.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.434460E+11 | 71306.30 | 01-JAN-02:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.422325E+11 | 71306.30 | 01-FEB-00:42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.227271E+11 | 71306.30 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.823283E+10 | 71306.30 | 03-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.152069E+09 | 61849.13 | 04-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.232895E+10 | 71306.30 | 17-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.131881E+11 | 71306.30 | 03-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.404059E+11 | 71306.30 | 02-DEC-02:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.172714E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.434460E+11 | 71306.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.154412E+12 | 178543.76 | 12-JAN-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.156560E+12 | 178543.76 | 06-FEB-09:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.589791E+11 | 99500.67 | 05-MAR-01:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.890927E+10 | 65765.86 | 16-APR-06:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 46573586.18 | 9572.40 | 30-OCT-04:47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196960E+11 | 43535.59 | 25-NOV-05:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.145213E+12 | 152643.13 | 09-DEC-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.543816E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.156560E+12 | 178543.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 3778251.32 | 3522962.28 | 543.34 | 15-MAR-15:10 | 503.86 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 88783041.70 | 84792722.00 | 2660.03 | 23-MAY-14:50 | 2660.03 | 0.00 |
June | 0.00 | 0.00 | 0.253313E+10 | 0.194377E+10 | 20240.09 | 27-JUN-05:23 | 9996.02 | 0.00 |
July | 0.00 | 0.00 | 0.680083E+10 | 0.483010E+10 | 22277.73 | 21-JUL-05:01 | 10302.07 | 0.00 |
August | 0.00 | 0.00 | 0.549458E+10 | 0.441874E+10 | 21635.24 | 14-AUG-05:01 | 9549.78 | 0.00 |
September | 0.00 | 0.00 | 0.138122E+10 | 0.105231E+10 | 20090.17 | 16-SEP-05:05 | 10310.40 | 0.00 |
October | 0.00 | 0.00 | 20.79 | 19.84 | 0.03 | 03-OCT-13:40 | 0.03 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.163023E+11 | 0.123332E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.680083E+10 | 0.483010E+10 | 22277.73 | 10310.40 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.117994E+10 | 0.764628E+09 | 58066.70 | 27-JUN-17:23 | 28379.12 | 0.00 |
July | 0.00 | 0.00 | 0.746153E+10 | 0.486381E+10 | 60253.56 | 21-JUL-03:45 | 26284.33 | 0.00 |
August | 0.00 | 0.00 | 0.487256E+10 | 0.376432E+10 | 57030.72 | 13-AUG-17:15 | 30583.63 | 0.00 |
September | 0.00 | 0.00 | 79691579.30 | 53990729.06 | 6049.43 | 16-SEP-13:40 | 4038.03 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.135937E+11 | 0.944675E+10 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.746153E+10 | 0.486381E+10 | 60253.56 | 30583.63 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT FAN
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.108833E+10 | 0.08 | 415.71 | 01-JAN-00:03 | 0.08 |
February | 0.986401E+09 | 0.08 | 415.71 | 01-FEB-00:03 | 0.08 |
March | 0.679830E+09 | 0.05 | 415.71 | 01-MAR-00:03 | 0.08 |
April | 0.199666E+09 | 0.01 | 415.71 | 01-APR-00:05 | 0.08 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 3741407.54 | 0.00 | 415.71 | 30-OCT-04:40 | 0.08 |
November | 0.496427E+09 | 0.04 | 415.71 | 02-NOV-21:47 | 0.08 |
December | 0.107902E+10 | 0.08 | 415.71 | 01-DEC-00:03 | 0.08 |
Annual Sum or Average | 0.453342E+10 | 0.03 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.108833E+10 | 0.08 | 415.71 | 0.08 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.115460E+10 | 0.67 | 1028.20 | 04-JAN-16:50 | 0.93 |
February | 0.107545E+10 | 0.67 | 1028.20 | 01-FEB-08:70 | 0.93 |
March | 0.117389E+10 | 0.52 | 1028.20 | 07-MAR-13:40 | 0.94 |
April | 0.105912E+10 | 0.43 | 1028.20 | 06-APR-11:00 | 0.93 |
May | 0.107370E+10 | 0.38 | 1028.20 | 01-MAY-09:40 | 0.93 |
June | 0.106182E+10 | 0.37 | 1028.20 | 01-JUN-11:30 | 0.92 |
July | 0.103966E+10 | 0.35 | 1028.20 | 01-JUL-07:40 | 0.92 |
August | 0.111824E+10 | 0.38 | 1028.20 | 01-AUG-07:10 | 0.92 |
September | 0.101882E+10 | 0.35 | 1028.20 | 05-SEP-06:40 | 0.93 |
October | 0.103671E+10 | 0.37 | 1028.20 | 02-OCT-06:40 | 0.93 |
November | 0.100948E+10 | 0.38 | 1028.20 | 01-NOV-11:50 | 0.93 |
December | 0.113143E+10 | 0.62 | 1028.20 | 01-DEC-08:30 | 0.93 |
Annual Sum or Average | 0.129529E+11 | 0.46 | |||
Minimum of Months | 0.100948E+10 | 0.35 | 1028.20 | 0.92 | |
Maximum of Months | 0.117389E+10 | 0.67 | 1028.20 | 0.94 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.185737E+10 | 0.64 | 2053.59 | 01-JAN-02:62 | 0.90 |
February | 0.176668E+10 | 0.64 | 2053.59 | 01-FEB-00:42 | 0.90 |
March | 0.143636E+10 | 0.54 | 2053.59 | 01-MAR-00:03 | 0.90 |
April | 0.102562E+10 | 0.40 | 2053.59 | 03-APR-05:01 | 0.90 |
May | 0.850000E+09 | 0.22 | 1781.23 | 04-MAY-05:01 | 0.90 |
June | 0.846172E+09 | 0.21 | 821.44 | 20-JUN-14:10 | 0.54 |
July | 0.851650E+09 | 0.22 | 2053.59 | 18-JUL-17:10 | 0.89 |
August | 0.899841E+09 | 0.23 | 1838.44 | 13-AUG-15:05 | 0.84 |
September | 0.813222E+09 | 0.21 | 821.44 | 16-SEP-14:50 | 0.54 |
October | 0.874550E+09 | 0.28 | 2053.59 | 17-OCT-05:01 | 0.90 |
November | 0.111273E+10 | 0.50 | 2053.59 | 03-NOV-05:01 | 0.90 |
December | 0.178767E+10 | 0.62 | 2053.59 | 02-DEC-02:62 | 0.90 |
Annual Sum or Average | 0.141219E+11 | 0.39 | |||
Minimum of Months | 0.813222E+09 | 0.21 | 821.44 | 0.54 | |
Maximum of Months | 0.185737E+10 | 0.64 | 2053.59 | 0.90 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.115460E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.107545E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.117467E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.105912E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.109134E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.153351E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.227765E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.212998E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.127810E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.103671E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.100948E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.113143E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.159520E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.100948E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.227765E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.185737E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.176668E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.143636E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.102562E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.850000E+09 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.111437E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.249200E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.200614E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.832043E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.874550E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.111273E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.178767E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.171555E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.832043E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.249200E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.115460E+10 | 0.00 | 0.112099E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.107545E+10 | 0.00 | 0.108392E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.117389E+10 | 3778251.32 | 0.748317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.105912E+10 | 0.00 | 0.415307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.107370E+10 | 88783041.70 | 0.921117E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.106182E+10 | 0.253313E+10 | 8122073.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.103966E+10 | 0.680083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.111824E+10 | 0.549458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.101882E+10 | 0.138122E+10 | 24380711.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.103671E+10 | 20.79 | 0.188194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.100948E+10 | 0.00 | 0.458713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.113143E+10 | 0.00 | 0.995674E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.129529E+11 | 0.163023E+11 | 0.510648E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.100948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.117389E+10 | 0.680083E+10 | 0.112099E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.185737E+10 | 0.00 | 0.434460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176668E+10 | 0.00 | 0.422325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143636E+10 | 0.00 | 0.227271E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.102562E+10 | 0.00 | 0.823283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.850000E+09 | 0.00 | 0.152069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.846172E+09 | 0.117008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.851650E+09 | 0.721294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.899841E+09 | 0.476188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.813222E+09 | 79691579.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.874550E+09 | 0.00 | 0.232895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.111273E+10 | 0.00 | 0.131881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.178767E+10 | 0.00 | 0.404059E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.141219E+11 | 0.132246E+11 | 0.172714E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.813222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.185737E+10 | 0.721294E+10 | 0.434460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.115460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.107545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.117389E+10 | 0.00 | 0.00 | 0.00 | 782387.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.105912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.107370E+10 | 0.00 | 0.00 | 0.00 | 17644185.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.106182E+10 | 0.00 | 0.00 | 0.00 | 0.471687E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.103966E+10 | 0.00 | 0.00 | 0.00 | 0.123799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.111824E+10 | 0.00 | 0.00 | 0.00 | 0.101174E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.101882E+10 | 0.00 | 0.00 | 0.00 | 0.259279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.103671E+10 | 0.00 | 0.00 | 0.00 | 4.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.100948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.113143E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.129529E+11 | 0.00 | 0.00 | 0.00 | 0.299912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.100948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.117389E+10 | 0.00 | 0.00 | 0.00 | 0.123799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.185737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.102562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.850000E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.846172E+09 | 0.00 | 0.00 | 0.00 | 0.268197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.851650E+09 | 0.00 | 0.00 | 0.00 | 0.164035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.899841E+09 | 0.00 | 0.00 | 0.00 | 0.110630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.813222E+09 | 0.00 | 0.00 | 0.00 | 18821471.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.874550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.111273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.178767E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.141219E+11 | 0.00 | 0.00 | 0.00 | 0.303367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.813222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.185737E+10 | 0.00 | 0.00 | 0.00 | 0.164035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.284102E+10 | 0.00 | 0.00 | 0.12 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266549E+10 | 0.00 | 0.00 | 0.13 |
March | 40381053.95 | 0.00 | 122987.86 | 0.00 | 546666.76 | 0.216880E+10 | 0.00 | 2860.10 | 0.13 |
April | 0.132355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137303E+10 | 0.00 | 0.00 | 0.13 |
May | 0.677333E+09 | 455917.81 | 0.00 | 189487.38 | 420.40 | 0.266748E+09 | 0.285206E+09 | 0.00 | 0.20 |
June | 0.121265E+09 | 0.207887E+09 | 0.00 | 2551392.80 | 2018338.41 | 0.00 | 0.176102E+10 | 0.00 | 0.50 |
July | 5069961.07 | 0.810715E+09 | 0.00 | 3154639.06 | 250141.70 | 0.00 | 0.747344E+09 | 0.00 | 0.52 |
August | 19740601.31 | 0.426282E+09 | 0.00 | 5138105.78 | 0.00 | 0.00 | 0.154321E+10 | 0.00 | 0.59 |
September | 0.168029E+09 | 83845923.97 | 0.00 | 2552917.43 | 0.00 | 2082565.71 | 0.196497E+10 | 0.00 | 0.54 |
October | 0.530975E+09 | 0.00 | 0.00 | 13434.85 | 0.00 | 0.823089E+09 | 51285726.41 | 0.00 | 0.13 |
November | 20379532.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165749E+10 | 0.00 | 0.00 | 0.12 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268481E+10 | 0.00 | 0.00 | 0.12 |
Annual Sum or Average | 0.171553E+10 | 0.152919E+10 | 122987.86 | 13599977.29 | 2815567.26 | 0.144826E+11 | 0.635304E+10 | 2860.10 | 0.27 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
Maximum of Months | 0.677333E+09 | 0.810715E+09 | 122987.86 | 5138105.78 | 2018338.41 | 0.284102E+10 | 0.196497E+10 | 2860.10 | 0.59 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 1463551.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.873968E+10 | 0.00 | 0.00 | 0.17 |
February | 0.229982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.801100E+10 | 0.00 | 0.00 | 0.17 |
March | 0.170719E+10 | 0.00 | 0.00 | 0.00 | 72378470.76 | 0.441510E+10 | 0.00 | 0.00 | 0.18 |
April | 0.264133E+10 | 0.00 | 0.00 | 0.00 | 4889728.46 | 0.977629E+09 | 0.00 | 0.00 | 0.18 |
May | 0.267069E+10 | 0.00 | 0.00 | 0.00 | 21692190.41 | 0.00 | 0.00 | 0.00 | 0.18 |
June | 0.256262E+10 | 0.135445E+09 | 0.00 | 749807.40 | 10760047.41 | 0.00 | 0.520939E+09 | 0.00 | 0.22 |
July | 0.681543E+09 | 0.761106E+09 | 0.00 | 3475643.86 | 0.00 | 0.00 | 0.160809E+10 | 0.00 | 0.29 |
August | 0.149469E+10 | 0.256200E+09 | 0.00 | 4515130.75 | 0.00 | 0.00 | 0.173121E+10 | 0.00 | 0.28 |
September | 0.306976E+10 | 8901.90 | 0.00 | 59871.75 | 531560.63 | 0.00 | 37901054.11 | 0.00 | 0.19 |
October | 0.321940E+10 | 0.00 | 0.00 | 0.00 | 1297873.03 | 0.162361E+09 | 0.00 | 0.00 | 0.17 |
November | 0.203203E+10 | 0.00 | 0.00 | 0.00 | 12074719.04 | 0.216804E+10 | 0.00 | 0.00 | 0.17 |
December | 0.218155E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.785999E+10 | 0.00 | 0.00 | 0.17 |
Annual Sum or Average | 0.205289E+11 | 0.115276E+10 | 0.00 | 8800453.77 | 0.123625E+09 | 0.323338E+11 | 0.389815E+10 | 0.00 | 0.20 |
Minimum of Months | 1463551.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
Maximum of Months | 0.321940E+10 | 0.761106E+09 | 0.00 | 4515130.75 | 72378470.76 | 0.873968E+10 | 0.173121E+10 | 0.00 | 0.29 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 10:43:17
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.235784E+12 | 0.129743E+12 | 0.00 | 0.115822E+11 | 0.459098E+11 |
February | 0.418894E+12 | 0.141050E+12 | 0.00 | 0.109065E+11 | 0.451751E+11 |
March | 0.693512E+12 | 0.719873E+11 | 0.00 | 0.825842E+10 | 0.213642E+11 |
April | 0.853637E+12 | 0.424275E+11 | 0.00 | 0.511945E+10 | 0.632046E+10 |
May | 0.109183E+13 | 0.301496E+11 | 0.00 | 0.387802E+10 | 0.532273E+09 |
June | 0.121741E+13 | 0.363441E+11 | 0.00 | 0.462075E+10 | 0.445673E+10 |
July | 0.115451E+13 | 0.354394E+11 | 0.00 | 0.146943E+10 | 0.171407E+11 |
August | 0.980081E+12 | 0.392965E+11 | 0.00 | 0.412496E+10 | 0.124852E+11 |
September | 0.716640E+12 | 0.339037E+11 | 0.00 | 0.516098E+10 | 0.174904E+10 |
October | 0.445409E+12 | 0.361350E+11 | 0.00 | 0.478583E+10 | 0.169897E+10 |
November | 0.194497E+12 | 0.433454E+11 | 0.00 | 0.586587E+10 | 0.103216E+11 |
December | 0.199203E+12 | 0.131333E+12 | 0.00 | 0.107630E+11 | 0.428488E+11 |
Annual Sum or Average | 0.820141E+13 | 0.771154E+12 | 0.00 | 0.765353E+11 | 0.210003E+12 |
Minimum of Months | 0.194497E+12 | 0.301496E+11 | 0.00 | 0.146943E+10 | 0.532273E+09 |
Maximum of Months | 0.121741E+13 | 0.141050E+12 | 0.00 | 0.115822E+11 | 0.459098E+11 |