Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:59
Tabular Output Report in Format: HTML
Building: HotelLarge
Environment: RUNPERIOD 1 ** New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860
Simulation Timestamp: 2023-10-16 08:59:43
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 11319.41 | 997.72 | 997.72 |
Net Site Energy | 11319.41 | 997.72 | 997.72 |
Total Source Energy | 24082.56 | 2122.69 | 2122.69 |
Net Source Energy | 24082.56 | 2122.69 | 2122.69 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 11345.29 |
Net Conditioned Building Area | 11345.29 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 761.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1189.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 766.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1745.01 | 1788.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 651.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 571.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 129.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 222.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 90.75 | 3097.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Refrigeration | 62.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 5670.82 | 5648.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 761.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 1189.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 766.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 959.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 762.04 | 1198.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 14.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 8.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 590.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 32.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 616.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 2.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 571.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 129.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 222.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Heater | 90.75 | 3097.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5742.51 | |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4114.69 | |
Refrigeration | General | 7.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 20.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 34.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 761.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 1189.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 766.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 1745.01 | 1788.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 651.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 571.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 129.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 222.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 90.75 | 3097.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Refrigeration | Unassigned | 62.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 88.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 174.60 | 340.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Other | 236.29 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 499.84 | 497.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 88.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 174.60 | 340.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Other | 236.29 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 499.84 | 497.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 5670.823 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 5670.823 | 100.00 |
Total On-Site and Utility Electric Sources | 5670.823 | 100.00 |
Total Electricity End Uses | 5670.823 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 555.57 | 15.95 |
Air to Air Heat Recovery for Heating | 2928.16 | 84.05 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 3483.73 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 9857.19 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 9857.19 | 100.00 |
Total Water End Uses | 9857.19 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 2.50 |
Time Setpoint Not Met During Occupied Cooling | 310.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8133.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_NEWYORK
| Environment |ZoneCoolingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneHeatingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneElectricSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |SpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |PeakSpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |SpaceGainComponentsAtCoolingPeakMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ComfortReportSimple55Monthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |OccupantComfortDataSummaryMonthly
| BASEMENT PEOPLE | RETAIL_1_FLR_1 PEOPLE | RETAIL_2_FLR_1 PEOPLE | LAUNDRY_FLR_1 PEOPLE | CAFE_FLR_1 PEOPLE | LOBBY_FLR_1 PEOPLE | ROOM_1_FLR_3 PEOPLE | ROOM_2_FLR_3 PEOPLE | ROOM_3_MULT19_FLR_3 PEOPLE | ROOM_4_MULT19_FLR_3 PEOPLE | ROOM_5_FLR_3 PEOPLE | ROOM_6_FLR_3 PEOPLE | ROOM_1_FLR_6 PEOPLE | ROOM_2_FLR_6 PEOPLE | ROOM_3_MULT9_FLR_6 PEOPLE | BANQUET_FLR_6 PEOPLE | DINING_FLR_6 PEOPLE | KITCHEN_FLR_6 PEOPLE | STORAGE_FLR_1 PEOPLE | CORRIDOR_FLR_3 PEOPLE | CORRIDOR_FLR_6 PEOPLE | MECH_FLR_1 PEOPLE |ChillerReportMonthly
| COOLSYS1 CHILLER1 |BoilerReportMonthly
| HEATSYS1 BOILER |DXReportMonthly
| VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |WindowReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowEnergyReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |WindowEnergyZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWH BOOSTER E WATER HEATER | SWH LAUNDRY G WATER HEATER | SWHSYS1 WATER HEATER |DaylightingReportMonthly
| LOBBY_FLR_1_DAYLCTRL | CAFE_FLR_1_DAYLCTRL | DINING_FLR_6_DAYLCTRL | BANQUET_FLR_6_DAYLCTRL |CoilReportMonthly
| VAV WITH REHEAT HEATING COIL | BASEMENT VAV BOX REHEAT COIL | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | MECH_FLR_1 VAV BOX REHEAT COIL | STORAGE_FLR_1 VAV BOX REHEAT COIL | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | CAFE_FLR_1 VAV BOX REHEAT COIL | LOBBY_FLR_1 VAV BOX REHEAT COIL | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | BANQUET_FLR_6 VAV BOX REHEAT COIL | DINING_FLR_6 VAV BOX REHEAT COIL | KITCHEN_FLR_6 VAV BOX REHEAT COIL | FLR_3_DOAS HEATING COIL | ROOM_1_FLR_3 FAN COIL HEATING COIL | ROOM_2_FLR_3 FAN COIL HEATING COIL | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_5_FLR_3 FAN COIL HEATING COIL | ROOM_6_FLR_3 FAN COIL HEATING COIL | ROOM_1_FLR_6 FAN COIL HEATING COIL | ROOM_2_FLR_6 FAN COIL HEATING COIL | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |PlantLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1 | SWHSYS1 |FanReportMonthly
| FLR_3_DOAS FAN | VAV WITH REHEAT FAN | LAUNDRY_FLR_1 EXHAUST FAN | LOBBY_FLR_1 EXHAUST FAN | BANQUET_FLR_6 EXHAUST FAN | DINING_FLR_6 EXHAUST FAN | KITCHEN_FLR_6 EXHAUST FAN | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN |PumpReportMonthly
| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | COOLSYS1 PUMP | SWHSYS1 PUMP |CondLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1 | SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AirLoopSystemEnergyAndWaterUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentLoadsMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentEnergyUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |MechanicalVentilationLoadsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:59 |
RunPeriod | RUNPERIOD 1 |
Weather File | New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 |
Latitude [deg] | 40.65 |
Longitude [deg] | -73.8 |
Elevation [m] | 5.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1213.79 | 432.95 | 85.85 | 609.15 | 85.85 |
Gross Window-Wall Ratio [%] | 26.62 | 23.11 | 21.12 | 32.52 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.15 | 26.05 | 24.48 | 36.65 | 24.48 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1213.79 | 432.95 | 85.85 | 609.15 | 85.85 |
Gross Window-Wall Ratio [%] | 26.62 | 23.11 | 21.12 | 32.52 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.15 | 26.05 | 24.48 | 36.65 | 24.48 |
Total | |
Gross Roof Area [m2] | 1978.84 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BASEMENT | 1978.83 | Yes | Yes | 4826.41 | 1.00 | 0.00 | 533.77 | 0.00 | 0.00 | 9.1389 | 18.58 | 5.3800 |
RETAIL_1_FLR_1 | 67.07 | Yes | Yes | 265.76 | 1.00 | 68.84 | 0.00 | 23.26 | 23.26 | 13.3365 | 6.19 | 10.7600 |
RETAIL_2_FLR_1 | 77.67 | Yes | Yes | 307.76 | 1.00 | 26.57 | 0.00 | 0.00 | 0.00 | 13.3365 | 6.19 | 10.7600 |
MECH_FLR_1 | 164.24 | Yes | Yes | 650.80 | 1.00 | 62.80 | 0.00 | 0.00 | 0.00 | 9.2031 | 61.93 | 5.3800 |
STORAGE_FLR_1 | 94.76 | Yes | Yes | 375.47 | 1.00 | 36.23 | 0.00 | 0.00 | 0.00 | 6.1031 | 46.45 | 2.6900 |
LAUNDRY_FLR_1 | 78.04 | Yes | Yes | 309.22 | 1.00 | 85.75 | 0.00 | 0.00 | 0.00 | 5.8125 | 9.29 | 597.5300 |
CAFE_FLR_1 | 188.86 | Yes | Yes | 748.35 | 1.00 | 152.17 | 0.00 | 65.50 | 65.50 | 10.3656 | 1.33 | 5.3800 |
LOBBY_FLR_1 | 1308.19 | Yes | Yes | 5183.56 | 1.00 | 434.79 | 0.00 | 85.08 | 85.08 | 8.7188 | 3.10 | 8.0700 |
ROOM_1_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_2_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_3_MULT19_FLR_3 | 24.52 | Yes | Yes | 74.75 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 4.5531 | 16.35 | 10.5200 |
ROOM_4_MULT19_FLR_3 | 24.53 | Yes | Yes | 74.77 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 4.5531 | 16.35 | 10.5200 |
ROOM_5_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_6_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
CORRIDOR_FLR_3 | 389.40 | Yes | Yes | 1186.91 | 4.00 | 48.31 | 0.00 | 15.94 | 15.94 | 6.3938 | 18.58 | 0.0000 |
ROOM_1_FLR_6 | 39.02 | Yes | Yes | 118.94 | 1.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_2_FLR_6 | 39.02 | Yes | Yes | 118.93 | 1.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_3_MULT9_FLR_6 | 24.53 | Yes | Yes | 74.77 | 9.00 | 20.44 | 0.00 | 6.74 | 6.74 | 4.5531 | 16.35 | 10.5200 |
BANQUET_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.19 | 32.19 | 10.3656 | 1.33 | 67.8200 |
DINING_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.19 | 32.19 | 10.3656 | 1.33 | 67.8200 |
KITCHEN_FLR_6 | 103.30 | Yes | Yes | 314.87 | 1.00 | 87.33 | 0.00 | 26.37 | 26.37 | 11.7219 | 4.65 | 2934.4875 |
CORRIDOR_FLR_6 | 412.12 | Yes | Yes | 1256.16 | 1.00 | 85.47 | 0.00 | 28.20 | 28.20 | 6.3938 | 18.58 | 0.0000 |
Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1213.79 | 1213.79 | 6.8557 | 7.07 | 41.0709 | |||
Conditioned Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1213.79 | 1213.79 | 6.8557 | 7.07 | 41.0709 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
BASEMENT | 1978.83 | Yes | Yes | 1.00 | BASEMENT | GENERAL | BASEMENT | 9.1389 | 18.58 | 5.3800 | |
RETAIL_1_FLR_1 | 67.07 | Yes | Yes | 1.00 | RETAIL_1_FLR_1 | GENERAL | RETAIL_1_FLR_1 | 13.3365 | 6.19 | 10.7600 | |
RETAIL_2_FLR_1 | 77.67 | Yes | Yes | 1.00 | RETAIL_2_FLR_1 | GENERAL | RETAIL_2_FLR_1 | 13.3365 | 6.19 | 10.7600 | |
MECH_FLR_1 | 164.24 | Yes | Yes | 1.00 | MECH_FLR_1 | GENERAL | MECH_FLR_1 | 9.2031 | 61.93 | 5.3800 | |
STORAGE_FLR_1 | 94.76 | Yes | Yes | 1.00 | STORAGE_FLR_1 | GENERAL | STORAGE_FLR_1 | 6.1031 | 46.45 | 2.6900 | |
LAUNDRY_FLR_1 | 78.04 | Yes | Yes | 1.00 | LAUNDRY_FLR_1 | GENERAL | LAUNDRY_FLR_1 | 5.8125 | 9.29 | 597.5300 | |
CAFE_FLR_1 | 188.86 | Yes | Yes | 1.00 | CAFE_FLR_1 | GENERAL | CAFE_FLR_1 | 10.3656 | 1.33 | 5.3800 | |
LOBBY_FLR_1 | 1308.19 | Yes | Yes | 1.00 | LOBBY_FLR_1 | GENERAL | LOBBY_FLR_1 | 8.7188 | 3.10 | 8.0700 | |
ROOM_1_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_1_FLR_3 | GENERAL | ROOM_1_FLR_3 | 4.5531 | 26.01 | 6.7500 | |
ROOM_2_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_2_FLR_3 | GENERAL | ROOM_2_FLR_3 | 4.5531 | 26.01 | 6.7500 | |
ROOM_3_MULT19_FLR_3 | 24.52 | Yes | Yes | 76.00 | ROOM_3_MULT19_FLR_3 | GENERAL | ROOM_3_MULT19_FLR_3 | 4.5531 | 16.35 | 10.5200 | |
ROOM_4_MULT19_FLR_3 | 24.53 | Yes | Yes | 76.00 | ROOM_4_MULT19_FLR_3 | GENERAL | ROOM_4_MULT19_FLR_3 | 4.5531 | 16.35 | 10.5200 | |
ROOM_5_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_5_FLR_3 | GENERAL | ROOM_5_FLR_3 | 4.5531 | 26.01 | 6.7500 | |
ROOM_6_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_6_FLR_3 | GENERAL | ROOM_6_FLR_3 | 4.5531 | 26.01 | 6.7500 | |
CORRIDOR_FLR_3 | 389.40 | Yes | Yes | 4.00 | CORRIDOR_FLR_3 | GENERAL | CORRIDOR_FLR_3 | 6.3938 | 18.58 | 0.0000 | |
ROOM_1_FLR_6 | 39.02 | Yes | Yes | 1.00 | ROOM_1_FLR_6 | GENERAL | ROOM_1_FLR_6 | 4.5531 | 26.01 | 6.7500 | |
ROOM_2_FLR_6 | 39.02 | Yes | Yes | 1.00 | ROOM_2_FLR_6 | GENERAL | ROOM_2_FLR_6 | 4.5531 | 26.01 | 6.7500 | |
ROOM_3_MULT9_FLR_6 | 24.53 | Yes | Yes | 9.00 | ROOM_3_MULT9_FLR_6 | GENERAL | ROOM_3_MULT9_FLR_6 | 4.5531 | 16.35 | 10.5200 | |
BANQUET_FLR_6 | 331.66 | Yes | Yes | 1.00 | BANQUET_FLR_6 | GENERAL | BANQUET_FLR_6 | 10.3656 | 1.33 | 67.8200 | |
DINING_FLR_6 | 331.66 | Yes | Yes | 1.00 | DINING_FLR_6 | GENERAL | DINING_FLR_6 | 10.3656 | 1.33 | 67.8200 | |
KITCHEN_FLR_6 | 103.30 | Yes | Yes | 1.00 | KITCHEN_FLR_6 | GENERAL | KITCHEN_FLR_6 | 11.7219 | 4.65 | 2934.4875 | |
CORRIDOR_FLR_6 | 412.12 | Yes | Yes | 1.00 | CORRIDOR_FLR_6 | GENERAL | CORRIDOR_FLR_6 | 6.3938 | 18.58 | 0.0000 | |
Total | 11345.29 | 6.8557 | 3.54 | 41.0709 | |||||||
Conditioned Total | 11345.29 | 6.8557 | 3.54 | 41.0709 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 11345.29 | 11345.29 | 0.00 | 0.00 | 4.4542 | 8.82 | 37.1989 |
Total | 11345.29 | 11345.29 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 04-AUG-19:10 | 05-FEB-19:10 | - | - | - | - | - | - | - | - | - | - | 12-JAN-21:19 |
Heating | 0.00 | 209264.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 199615.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 62892.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 15448.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 88772.42 | 83438.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 32150.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 33670.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 7013.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 9938.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 3529.80 | 267304.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 1873.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 454905.91 | 560006.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 209264.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 199615.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 62892.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 15448.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 58789.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 29240.64 | 49984.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 457.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 285.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 33453.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 1846.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 30153.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 150.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 33670.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 7013.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 9938.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Heater | 3529.80 | 267304.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 241.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 536.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 1096.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 825.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 3766.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 2427.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 768.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 5526.46 | 1939.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 2063.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1810.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 409.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 703.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 287.39 | 3358.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 196.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 17959.50 | 6123.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 72.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 331.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 213.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 67.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 487.11 | 170.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 181.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 159.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 36.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 62.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.33 | 296.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 17.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1582.99 | 539.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 72.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 331.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 213.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 67.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 487.11 | 170.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 181.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 159.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 36.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 62.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.33 | 296.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 17.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1582.99 | 539.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
BASEMENT VAV BOX COMPONENT | 2.52 | 0.599008 | 0.528000 | 1.33 | 1.00 | 0.500000 | 0.000636 | 0.000061 | 1.33 | 16.70 | 0.008000 |
RETAIL_1_FLR_1 VAV BOX COMPONENT | 0.388518 | 0.131547 | 0.528000 | 0.205138 | 0.528000 | 0.500000 | 0.002896 | 0.000036 | 0.205138 | 16.70 | 0.008000 |
RETAIL_2_FLR_1 VAV BOX COMPONENT | 0.240329 | 0.246261 | 0.528000 | 0.126894 | 0.656697 | 0.500000 | 0.001547 | 0.000015 | 0.126894 | 16.70 | 0.008000 |
MECH_FLR_1 VAV BOX COMPONENT | 0.233530 | 0.535921 | 0.528000 | 0.123304 | 1.00 | 0.500000 | 0.000711 | 0.000023 | 0.123304 | 16.70 | 0.008000 |
STORAGE_FLR_1 VAV BOX COMPONENT | 0.113177 | 0.637997 | 0.528000 | 0.059757 | 1.00 | 0.500000 | 0.000597 | 0.000013 | 0.059757 | 16.70 | 0.008000 |
LAUNDRY_FLR_1 VAV BOX COMPONENT | 3.26 | 0.072292 | 0.528000 | 1.72 | 0.528000 | 0.500000 | 0.020914 | 0.000102 | 1.72 | 16.70 | 0.008000 |
CAFE_FLR_1 VAV BOX COMPONENT | 1.57 | 0.091791 | 0.528000 | 0.827817 | 0.528000 | 0.500000 | 0.004151 | 0.000104 | 0.827817 | 16.70 | 0.008000 |
LOBBY_FLR_1 VAV BOX COMPONENT | 4.76 | 0.209364 | 0.528000 | 2.51 | 0.558304 | 0.500000 | 0.001820 | 0.000275 | 2.51 | 16.70 | 0.008000 |
CORRIDOR_FLR_3 VAV BOX COMPONENT | 1.50 | 0.789112 | 0.528000 | 0.794166 | 1.00 | 0.500000 | 0.000483 | 0.000132 | 0.794166 | 16.70 | 0.008000 |
BANQUET_FLR_6 VAV BOX COMPONENT | 2.18 | 0.116121 | 0.528000 | 1.15 | 0.528000 | 0.500000 | 0.003281 | 0.000111 | 1.15 | 16.70 | 0.008000 |
DINING_FLR_6 VAV BOX COMPONENT | 2.28 | 0.110807 | 0.528000 | 1.20 | 0.528000 | 0.500000 | 0.003438 | 0.000115 | 1.20 | 16.70 | 0.008000 |
KITCHEN_FLR_6 VAV BOX COMPONENT | 2.27 | 0.062385 | 0.528000 | 1.20 | 0.528000 | 0.500000 | 0.010985 | 0.000077 | 1.20 | 16.70 | 0.008000 |
CORRIDOR_FLR_6 VAV BOX COMPONENT | 0.774596 | 0.405423 | 0.528000 | 0.408987 | 1.00 | 0.500000 | 0.000940 | 0.000079 | 0.408987 | 16.70 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
BASEMENT VAV BOX REHEAT COIL | 7014.41 | 0.000061 | 146.27 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 4102.09 | 0.000036 | 100.29 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 1721.57 | 0.000015 | 39.11 |
MECH_FLR_1 VAV BOX REHEAT COIL | 2604.15 | 0.000023 | 64.53 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | 1495.16 | 0.000013 | 38.91 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 11674.17 | 0.000102 | 247.08 |
CAFE_FLR_1 VAV BOX REHEAT COIL | 11909.29 | 0.000104 | 273.01 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | 31385.41 | 0.000275 | 704.72 |
ROOM_1_FLR_3 FAN COIL HEATING COIL | 6925.28 | 0.000061 | 197.91 |
ROOM_2_FLR_3 FAN COIL HEATING COIL | 6944.49 | 0.000061 | 198.45 |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | 39426.23 | 0.000345 | 1126.68 |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | 39798.13 | 0.000348 | 1137.30 |
ROOM_5_FLR_3 FAN COIL HEATING COIL | 6886.18 | 0.000060 | 196.79 |
ROOM_6_FLR_3 FAN COIL HEATING COIL | 6905.40 | 0.000060 | 197.34 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 15090.80 | 0.000132 | 364.61 |
ROOM_1_FLR_6 FAN COIL HEATING COIL | 2085.98 | 0.000018 | 59.61 |
ROOM_2_FLR_6 FAN COIL HEATING COIL | 2092.41 | 0.000018 | 59.79 |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | 9911.65 | 0.000087 | 283.23 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | 12730.98 | 0.000111 | 281.61 |
DINING_FLR_6 VAV BOX REHEAT COIL | 13167.56 | 0.000115 | 290.82 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | 8850.44 | 0.000077 | 188.47 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 9028.71 | 0.000079 | 226.38 |
VAV WITH REHEAT HEATING COIL | 218405.54 | 0.001911 | 3604.87 |
FLR_3_DOAS HEATING COIL | 20393.42 | 0.000178 | 336.60 |
User-Specified Maximum Flow Rate [m3/s] | |
LOBBY_FLR_1 EXHAUST FAN | 0.000000 |
Design Size Maximum Air Flow Rate [m3/s] | |
ROOM_1_FLR_3 DIRECT AIR | 0.061735 |
ROOM_2_FLR_3 DIRECT AIR | 0.061728 |
ROOM_3_MULT19_FLR_3 DIRECT AIR | 0.837072 |
ROOM_4_MULT19_FLR_3 DIRECT AIR | 0.837300 |
ROOM_5_FLR_3 DIRECT AIR | 0.061735 |
ROOM_6_FLR_3 DIRECT AIR | 0.061728 |
ROOM_1_FLR_6 DIRECT AIR | 0.015434 |
ROOM_2_FLR_6 DIRECT AIR | 0.015432 |
ROOM_3_MULT9_FLR_6 DIRECT AIR | 0.099154 |
Design Size Maximum Supply Air Flow Rate [m3/s] | Design Size Maximum Hot Water Flow [m3/s] | Design Size Maximum Cold Water Flow [m3/s] | |
ROOM_1_FLR_3 FAN COIL | 1.14 | 0.000061 | 0.000465 |
ROOM_2_FLR_3 FAN COIL | 1.10 | 0.000061 | 0.000451 |
ROOM_3_MULT19_FLR_3 FAN COIL | 6.53 | 0.000345 | 0.002614 |
ROOM_4_MULT19_FLR_3 FAN COIL | 5.76 | 0.000348 | 0.002464 |
ROOM_5_FLR_3 FAN COIL | 1.04 | 0.000060 | 0.000425 |
ROOM_6_FLR_3 FAN COIL | 1.01 | 0.000060 | 0.000414 |
ROOM_1_FLR_6 FAN COIL | 0.299295 | 0.000018 | 0.000122 |
ROOM_2_FLR_6 FAN COIL | 0.289526 | 0.000018 | 0.000118 |
ROOM_3_MULT9_FLR_6 FAN COIL | 1.37 | 0.000087 | 0.000566 |
Design Size Maximum Flow Rate [m3/s] | |
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | 1.14 |
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | 1.10 |
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | 6.53 |
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | 5.76 |
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | 1.04 |
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | 1.01 |
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | 0.299295 |
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | 0.289526 |
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | 1.37 |
Design Size Design Inlet Air Temperature [C] | Design Size Design Inlet Water Temperature [C] | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Outlet Air Temperature [C] | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Water Flow Rate [m3/s] | Design Size Design Air Flow Rate [m3/s] | Design Size Design Coil Load [W] | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008667 | 12.80 | 0.008500 | 0.000465 | 1.14 | |
ROOM_2_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008672 | 12.80 | 0.008500 | 0.000451 | 1.10 | |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008596 | 12.80 | 0.008500 | 0.002614 | 6.53 | |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008848 | 12.80 | 0.008500 | 0.002464 | 5.76 | |
ROOM_5_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008684 | 12.80 | 0.008500 | 0.000425 | 1.04 | |
ROOM_6_FLR_3 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008690 | 12.80 | 0.008500 | 0.000414 | 1.01 | |
ROOM_1_FLR_6 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008659 | 12.80 | 0.008500 | 0.000122 | 0.299295 | |
ROOM_2_FLR_6 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008665 | 12.80 | 0.008500 | 0.000118 | 0.289526 | |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | 21.68 | 6.70 | 0.008719 | 12.80 | 0.008500 | 0.000566 | 1.37 | |
VAV WITH REHEAT COOLING COIL | 28.30 | 6.70 | 0.012038 | 10.99 | 0.008500 | 0.025218 | 21.97 | 706034.18 |
FLR_3_DOAS COOLING COIL | 32.10 | 6.70 | 0.014120 | 11.94 | 0.008500 | 0.003084 | 2.05 | 86334.71 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
VAV WITH REHEAT | 11.66 | 11.66 | 22.09 | 11.66 | 21.97 | 21.97 | 0.300000 | 0.530948 | 21.97 |
FLR_3_DOAS | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 0.300000 | 1.00 | 2.05 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
VAV WITH REHEAT_OA_CONTROLLER | 21.97 | 11.66 |
FLR_3_DOAS_OA_CONTROLLER | 2.05 | 2.05 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
VAV WITH REHEAT OA HEAT RECOVERY | 11.66 |
FLR_3_DOAS OA HEAT RECOVERY | 2.05 |
Design Size Maximum Flow Rate [m3/s] | |
VAV WITH REHEAT FAN | 21.97 |
Maximum Actuated Flow [m3/s] | Controller Convergence Tolerance | |
VAV WITH REHEAT_COOLC_CONTROLLER | 0.025218 | 0.000019 |
VAV WITH REHEAT_HEATC_CONTROLLER | 0.001911 | |
FLR_3_DOAS_COOLC_CONTROLLER | 0.003084 | 0.000154 |
FLR_3_DOAS_HEATC_CONTROLLER | 0.000178 |
User-Specified Maximum Flow Rate [m3/s] | |
FLR_3_DOAS FAN | 2.05 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | Design Minimum Flow Rate [m3/s] | |
COOLSYS1 PUMP SECONDARY | 0.035941 | 7406.11 | |
HEATSYS1 PUMP | 0.004292 | 1292.42 | 0.000000 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
HEATSYS1 | 0.004292 | 0.514985 |
COOLSYS1 | 0.035941 | 4.31 |
SWHSYS1 | 0.000375 | 0.045004 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 490549.46 | 490549.46 | 0.004292 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
COOLSYS1 PUMP | 0.035941 | 5127.50 |
SWHSYS1 PUMP | 0.000375 | 47.91 |
Design Size Reference Chilled Water Flow Rate [m3/s] | Design Size Reference Capacity [W] | User-Specified Reference Capacity [W] | Design Size Reference Condenser Fluid Flow Rate [m3/s] | |
COOLSYS1 CHILLER1 | 0.035941 | 1006252.25 | 1006860.85 | 114.78 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000375 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesPossible Shadow Receivers | |
RETAIL_1_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
CAFE_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
LOBBY_FLR_1_CEILING_2 | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
Possible Shadow Receivers | |
RETAIL_1_FLR_1_WALL_SOUTH | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | |
RETAIL_2_FLR_1_WALL_WEST | RETAIL_2_FLR_1_WALL_WEST_DOOR | |
STORAGE_FLR_1_WALL_NORTH | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | |
LAUNDRY_FLR_1_WALL_EAST | LAUNDRY_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_EAST | CAFE_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_SOUTH | CAFE_FLR_1_WALL_SOUTH_WINDOW | |
LOBBY_FLR_1_WALL_1_NORTH | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | |
LOBBY_FLR_1_WALL_1_SOUTH | LOBBY_FLR_1_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_SOUTH | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_WEST | ROOM_1_FLR_3_WALL_WEST_WINDOW | |
ROOM_2_FLR_3_WALL_NORTH | ROOM_2_FLR_3_WALL_NORTH_WINDOW | |
ROOM_2_FLR_3_WALL_WEST | ROOM_2_FLR_3_WALL_WEST_WINDOW | |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_4_MULT19_FLR_3_WALL_NORTH | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | |
ROOM_5_FLR_3_WALL_EAST | ROOM_5_FLR_3_WALL_EAST_WINDOW | |
ROOM_5_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_6_FLR_3_WALL_NORTH | ROOM_6_FLR_3_WALL_NORTH_WINDOW | |
ROOM_6_FLR_3_WALL_EAST | ROOM_6_FLR_3_WALL_EAST_WINDOW | |
CORRIDOR_FLR_3_WALL_1_NORTH | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_NORTH | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_SOUTH | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_WEST | ROOM_1_FLR_6_WALL_WEST_WINDOW | |
ROOM_2_FLR_6_WALL_NORTH | ROOM_2_FLR_6_WALL_NORTH_WINDOW | |
ROOM_2_FLR_6_WALL_WEST | ROOM_2_FLR_6_WALL_WEST_WINDOW | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | |
BANQUET_FLR_6_WALL_NORTH | BANQUET_FLR_6_WALL_NORTH_WINDOW | |
DINING_FLR_6_WALL_NORTH | DINING_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_NORTH | KITCHEN_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_EAST | KITCHEN_FLR_6_WALL_EAST_WINDOW | |
KITCHEN_FLR_6_WALL_1_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_6_WALL_1_NORTH | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_NORTH | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 14.00 | 7.30 | 3.30 | 1.20 | -0.20 | 5.60 | 10.90 | 16.10 | 21.70 | 25.00 | 24.80 | 19.90 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 | 40.65 | -73.80 | -5.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 12.47 | 25.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | HotelLarge | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | DOE-2 |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 22 | 235 | 36 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BASEMENT | 0.0 | 0.00 | 0.00 | 0.00 | 41.45 | 11.51 | -1.22 | 1 | 1 | 1 | 0.00 | 86.56 | 0.00 | 22.86 | -2.44 | 0.00 | 2.44 | 4826.41 | TARP | DOE-2 | 1978.83 | 0.00 | 0.00 | 0.00 | 13 | 0 | 0 | Yes |
2 | RETAIL_1_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 2.90 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 265.76 | TARP | DOE-2 | 67.07 | 68.84 | 45.58 | 23.26 | 6 | 1 | 0 | Yes |
3 | RETAIL_2_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 9.14 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 5.79 | 12.50 | 0.00 | 3.96 | 3.96 | 307.76 | TARP | DOE-2 | 77.67 | 26.57 | 24.62 | 0.00 | 6 | 1 | 0 | Yes |
4 | MECH_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 61.87 | 17.68 | 1.98 | 1 | 1 | 1 | 53.95 | 69.80 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 650.80 | TARP | DOE-2 | 164.24 | 62.80 | 62.80 | 0.00 | 6 | 0 | 0 | Yes |
5 | STORAGE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 74.37 | 17.68 | 1.98 | 1 | 1 | 1 | 69.80 | 78.94 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 375.47 | TARP | DOE-2 | 94.76 | 36.23 | 28.80 | 0.00 | 6 | 1 | 0 | Yes |
6 | LAUNDRY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 14.33 | 1.98 | 1 | 1 | 1 | 81.99 | 86.56 | 5.79 | 22.86 | 0.00 | 3.96 | 3.96 | 309.22 | TARP | DOE-2 | 78.04 | 85.75 | 83.80 | 0.00 | 6 | 1 | 0 | Yes |
7 | CAFE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 70.26 | 2.90 | 1.98 | 1 | 1 | 1 | 53.95 | 86.56 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 748.35 | TARP | DOE-2 | 188.86 | 152.17 | 84.72 | 65.50 | 7 | 2 | 0 | Yes |
8 | LOBBY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 38.29 | 12.45 | 1.98 | 1 | 1 | 1 | 0.00 | 81.99 | 0.00 | 22.86 | 0.00 | 3.96 | 3.96 | 5183.56 | TARP | DOE-2 | 1308.19 | 434.79 | 345.80 | 85.08 | 18 | 3 | 0 | Yes |
9 | ROOM_1_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
10 | ROOM_2_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
11 | ROOM_3_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 8.53 | 9.14 | 8.53 | 1 | 76 | 1 | 6.71 | 10.36 | 5.79 | 12.50 | 7.01 | 10.06 | 3.05 | 74.75 | TARP | DOE-2 | 24.52 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
12 | ROOM_4_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 12.19 | 19.51 | 8.53 | 1 | 76 | 1 | 10.36 | 14.02 | 16.15 | 22.86 | 7.01 | 10.06 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
13 | ROOM_5_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 10.06 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
14 | ROOM_6_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 18.59 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
15 | CORRIDOR_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 43.28 | 14.33 | 8.53 | 1 | 4 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 7.01 | 10.06 | 3.05 | 1186.91 | TARP | DOE-2 | 389.40 | 48.31 | 32.37 | 15.94 | 20 | 4 | 0 | Yes |
16 | ROOM_1_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 16.15 | 19.20 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
17 | ROOM_2_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 16.15 | 19.20 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
18 | ROOM_3_MULT9_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 7.93 | 7.62 | 17.68 | 1 | 9 | 1 | 4.57 | 11.28 | 5.79 | 9.45 | 16.15 | 19.20 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 20.44 | 13.70 | 6.74 | 6 | 1 | 0 | Yes |
19 | BANQUET_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 26.37 | 17.68 | 17.68 | 1 | 1 | 1 | 10.36 | 42.37 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.36 | 32.19 | 6 | 1 | 0 | Yes |
20 | DINING_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 63.55 | 17.68 | 17.68 | 1 | 1 | 1 | 47.55 | 79.55 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.36 | 32.19 | 6 | 1 | 0 | Yes |
21 | KITCHEN_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 82.99 | 14.11 | 17.68 | 1 | 1 | 1 | 79.55 | 86.56 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 314.87 | TARP | DOE-2 | 103.30 | 87.33 | 60.96 | 26.37 | 8 | 3 | 0 | Yes |
22 | CORRIDOR_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 41.51 | 13.35 | 17.68 | 1 | 1 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 1256.16 | TARP | DOE-2 | 412.12 | 85.47 | 57.27 | 28.20 | 15 | 3 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BASEMENT | 1978.83 | 106.5 | 18.581 | 5.382E-002 | 9.139 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 14.519 | No |
2 | RETAIL_1_FLR_1 | 67.07 | 10.8 | 6.194 | 0.161 | 13.336 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 24.096 | No |
3 | RETAIL_2_FLR_1 | 77.67 | 12.5 | 6.194 | 0.161 | 13.336 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 24.096 | No |
4 | MECH_FLR_1 | 164.24 | 2.7 | 61.932 | 1.615E-002 | 9.203 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 14.583 | No |
5 | STORAGE_FLR_1 | 94.76 | 2.0 | 46.451 | 2.153E-002 | 6.103 | 2.690 | 0.000 | 0.000 | 0.000 | 0.000 | 8.793 | No |
6 | LAUNDRY_FLR_1 | 78.04 | 8.4 | 9.290 | 0.108 | 5.813 | 61.680 | 535.850 | 0.000 | 0.000 | 0.000 | 603.343 | No |
7 | CAFE_FLR_1 | 188.86 | 142.3 | 1.327 | 0.753 | 10.366 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 15.746 | No |
8 | LOBBY_FLR_1 | 1308.19 | 422.4 | 3.097 | 0.323 | 8.719 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.789 | No |
9 | ROOM_1_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
10 | ROOM_2_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
11 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 16.349 | 6.116E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
12 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
13 | ROOM_5_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
14 | ROOM_6_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
15 | CORRIDOR_FLR_3 | 389.40 | 21.0 | 18.581 | 5.382E-002 | 6.394 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.394 | No |
16 | ROOM_1_FLR_6 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
17 | ROOM_2_FLR_6 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
18 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
19 | BANQUET_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 10.366 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 78.186 | No |
20 | DINING_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 10.366 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 78.186 | No |
21 | KITCHEN_FLR_6 | 103.30 | 22.2 | 4.645 | 0.215 | 11.722 | 515.227 | 2419.260 | 0.000 | 0.000 | 0.000 | 2946.209 | No |
22 | CORRIDOR_FLR_6 | 412.12 | 22.2 | 18.581 | 5.382E-002 | 6.394 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.394 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | BASEMENT PEOPLE | BLDG_OCC_SCH | BASEMENT | 1978.83 | 106.5 | 106.5 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 106 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | RETAIL_1_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 10.8 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | RETAIL_2_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 12.5 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 13 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | LAUNDRY_FLR_1 PEOPLE | BLDG_OCC_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 8.4 | 0.108 | 9.290 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 8 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | CAFE_FLR_1 PEOPLE | BLDG_OCC_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 142.3 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 142 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | LOBBY_FLR_1 PEOPLE | BLDG_OCC_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 422.4 | 0.323 | 3.097 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 422 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | ROOM_1_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | ROOM_2_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | ROOM_3_MULT19_FLR_3 PEOPLE | ALWAYS_OFF | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 1.5 | 6.116E-002 | 16.349 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | ROOM_4_MULT19_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | ROOM_5_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | ROOM_6_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | ROOM_1_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | ROOM_2_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | ROOM_3_MULT9_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
16 | BANQUET_FLR_6 PEOPLE | BLDG_OCC_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
17 | DINING_FLR_6 PEOPLE | BLDG_OCC_SCH | DINING_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
18 | KITCHEN_FLR_6 PEOPLE | BLDG_OCC_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 22.2 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
19 | STORAGE_FLR_1 PEOPLE | BLDG_OCC_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 2.0 | 2.153E-002 | 46.451 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
20 | CORRIDOR_FLR_3 PEOPLE | BLDG_OCC_SCH | CORRIDOR_FLR_3 | 389.40 | 21.0 | 21.0 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 21 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
21 | CORRIDOR_FLR_6 PEOPLE | BLDG_OCC_SCH | CORRIDOR_FLR_6 | 412.12 | 22.2 | 22.2 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
22 | MECH_FLR_1 PEOPLE | BLDG_OCC_SCH | MECH_FLR_1 | 164.24 | 2.7 | 2.7 | 1.615E-002 | 61.932 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 3 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BASEMENT_LIGHTS | LTG_SCH_BASEMENT | BASEMENT | 1978.83 | 106.5 | 18084.325 | 9.139 | 169.807 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 18084.325 |
2 | RETAIL_1_FLR_1_LIGHTS | LTG_SCH_RETAIL | RETAIL_1_FLR_1 | 67.07 | 10.8 | 894.495 | 13.336 | 82.602 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 894.495 |
3 | RETAIL_2_FLR_1_LIGHTS | LTG_SCH_RETAIL | RETAIL_2_FLR_1 | 77.67 | 12.5 | 1035.829 | 13.336 | 82.602 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1035.829 |
4 | MECH_FLR_1_LIGHTS | LTG_SCH_MECHANIC | MECH_FLR_1 | 164.24 | 2.7 | 1511.551 | 9.203 | 569.967 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1511.551 |
5 | STORAGE_FLR_1_LIGHTS | LTG_SCH_STORAGE | STORAGE_FLR_1 | 94.76 | 2.0 | 578.329 | 6.103 | 283.494 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 578.329 |
6 | LAUNDRY_FLR_1_LIGHTS | LTG_SCH_LAUNDRY | LAUNDRY_FLR_1 | 78.04 | 8.4 | 453.605 | 5.813 | 54.001 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 453.605 |
7 | CAFE_FLR_1_LIGHTS | LTG_SCH_DINING | CAFE_FLR_1 | 188.86 | 142.3 | 1957.673 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1957.673 |
8 | LOBBY_FLR_1_LIGHTS | LTG_SCH_LOBBY | LOBBY_FLR_1 | 1308.19 | 422.4 | 11405.759 | 8.719 | 27.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 11405.759 |
9 | ROOM_1_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_1_FLR_3 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
10 | ROOM_2_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_2_FLR_3 | 39.02 | 1.5 | 177.651 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.651 |
11 | ROOM_3_MULT19_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 111.660 | 4.553 | 74.440 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.660 |
12 | ROOM_4_MULT19_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 111.691 | 4.553 | 74.460 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.691 |
13 | ROOM_5_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_5_FLR_3 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
14 | ROOM_6_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_6_FLR_3 | 39.02 | 1.5 | 177.651 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.651 |
15 | CORRIDOR_FLR_3_LIGHTS | LTG_SCH_CORRIDOR | CORRIDOR_FLR_3 | 389.40 | 21.0 | 2489.757 | 6.394 | 118.803 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2489.757 |
16 | ROOM_1_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_1_FLR_6 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
17 | ROOM_2_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_2_FLR_6 | 39.02 | 1.5 | 177.651 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.651 |
18 | ROOM_3_MULT9_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 111.691 | 4.553 | 74.460 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.691 |
19 | BANQUET_FLR_6_LIGHTS | LTG_SCH_DINING | BANQUET_FLR_6 | 331.66 | 249.9 | 3437.839 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3437.839 |
20 | DINING_FLR_6_LIGHTS | LTG_SCH_DINING | DINING_FLR_6 | 331.66 | 249.9 | 3437.839 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3437.839 |
21 | KITCHEN_FLR_6_LIGHTS | LTG_SCH_KITCHEN | KITCHEN_FLR_6 | 103.30 | 22.2 | 1210.923 | 11.722 | 54.453 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1210.923 |
22 | CORRIDOR_FLR_6_LIGHTS | LTG_SCH_CORRIDOR | CORRIDOR_FLR_6 | 412.12 | 22.2 | 2635.024 | 6.394 | 118.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2635.024 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BASEMENT_MISCPLUG_EQUIP | BASEMENT_EQUIP_SCH | BASEMENT | 1978.83 | 106.5 | 10646.106 | 5.380 | 99.964 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10646.106 |
2 | RETAIL_1_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 721.688 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 721.688 |
3 | RETAIL_2_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 835.717 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 835.717 |
4 | MECH_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | MECH_FLR_1 | 164.24 | 2.7 | 883.628 | 5.380 | 333.193 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 883.628 |
5 | STORAGE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 254.902 | 2.690 | 124.952 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 254.902 |
6 | LAUNDRY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 4813.474 | 61.680 | 573.033 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 4813.474 |
7 | CAFE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 1016.077 | 5.380 | 7.140 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1016.077 |
8 | LOBBY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 10557.062 | 8.070 | 24.991 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10557.062 |
9 | ROOM_1_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
10 | ROOM_2_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
11 | ROOM_3_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 257.991 | 10.520 | 171.994 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 257.991 |
12 | ROOM_4_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
13 | ROOM_5_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_5_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
14 | ROOM_6_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_6_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
15 | ROOM_1_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_6 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
16 | ROOM_2_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_6 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
17 | ROOM_3_MULT9_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
18 | BANQUET_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
19 | DINING_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | DINING_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
20 | KITCHEN_FLR_6_MISCELEC_EQUIP | KITCHEN_ELEC_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 52482.799 | 508.040 | 2360.050 | 0.200 | 0.500 | 0.100 | 0.200 | Cooking | 0.000 | 15744.840 |
21 | KITCHEN_FLR_6_REACH-IN-FREEZER | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 457.500 | 4.429 | 20.573 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInFreezer | 457.500 | 457.500 |
22 | KITCHEN_FLR_6_REACH-IN-REFRIGERATOR | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 285.000 | 2.759 | 12.816 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInRefrigerator | 285.000 | 285.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LAUNDRY_FLR_1_MISCGAS_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 41817.449 | 535.850 | 4978.268 | 0.000 | 0.500 | 0.000 | 0.500 | Laundry | 0.000 | 41817.449 |
2 | KITCHEN_FLR_6_MISCGAS_EQUIP | KITCHEN_GAS_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 249920.353 | 2419.260 | 11238.437 | 0.100 | 0.200 | 0.700 | 0.000 | Cooking | 0.000 | 74976.106 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | RES_ROOF | 19 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
7 | NONRES_EXT_WALL_GRD | 21 | 3 | 9 | 0.167 | 0.9242 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | NONRES_EXT_WALL_MID | 22 | 3 | 9 | 0.167 | 1.217 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | NONRES_EXT_WALL_TOP | 23 | 3 | 9 | 0.167 | 1.286 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
10 | RES_EXT_WALL_MID | 25 | 3 | 9 | 0.167 | 1.107 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
11 | RES_EXT_WALL_TOP | 26 | 3 | 9 | 0.167 | 1.174 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | NONRES_FLOOR | 30 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
13 | NONRES_FLOOR_CEILING | 33 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
14 | BASEMENT_FLOOR | 36 | 2 | 7 | 0.333 | 2.705 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
15 | BASEMENT_WALL_NORTH_CFACTOR | 39 | 2 | 7 | 0.167 | 0.4185 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
16 | BASEMENT_WALL_EAST_CFACTOR | 40 | 2 | 7 | 0.167 | 0.4185 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
17 | BASEMENT_WALL_SOUTH_CFACTOR | 41 | 2 | 7 | 0.167 | 0.4185 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
18 | BASEMENT_WALL_WEST_CFACTOR | 42 | 2 | 7 | 0.167 | 0.4185 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
10 | RES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
11 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
12 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
13 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9147 |
14 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
15 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
16 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6546 |
17 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
18 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6103 |
20 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
21 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
22 | RES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7359 |
23 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
24 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
25 | RES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6841 |
26 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
27 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
28 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
29 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
30 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
31 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
32 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
33 | M10 200MM CONCRETE BLOCK BASEMENT WALL | 0.2032 | 1.326 | 1842.000 | 912.000 | 0.1532 |
34 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
35 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.312 |
36 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
37 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.312 |
38 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
39 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.312 |
40 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
41 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.312 |
42 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637404 | 3.4637404 | 3.4637404 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
21 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
22 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
23 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
24 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
25 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
26 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
27 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
28 | 9 | -0.28612306E-14 | 0.35438919E-16 | -0.14997333E-09 | 0.48037931E-16 |
29 | 8 | 0.21910456E-07 | 0.12451452E-12 | 0.37817107E-03 | -0.24912943E-09 |
30 | 7 | -0.12252860E-01 | 0.64616398E-08 | -0.23102096E-01 | 0.13931948E-03 |
31 | 6 | 0.40565756 | 0.22511349E-05 | 0.47235308 | -0.47513834E-02 |
32 | 5 | -5.1935619 | 0.84157732E-04 | -4.4432762 | 0.63221026E-01 |
33 | 4 | 33.016121 | 0.68920660E-03 | 21.448225 | -0.42229901 |
34 | 3 | -111.25447 | 0.15035857E-02 | -55.639617 | 1.5156026 |
35 | 2 | 197.15924 | 0.84653085E-03 | 77.889127 | -2.9011628 |
36 | 1 | -171.17492 | 0.90445513E-04 | -55.258822 | 2.7457697 |
37 | 0 | 57.057407 | 0.51539406E-06 | 15.557951 | |
38 | 9 | 0.12430042E-14 | 0.43603463E-16 | -0.13615479E-09 | -0.52742981E-17 |
39 | 8 | 0.19963588E-07 | 0.16114398E-12 | 0.35741204E-03 | -0.22699287E-09 |
40 | 7 | -0.11632381E-01 | 0.85488282E-08 | -0.22208377E-01 | 0.13226440E-03 |
41 | 6 | 0.38879653 | 0.30047059E-05 | 0.45796739 | -0.45526330E-02 |
42 | 5 | -5.0290001 | 0.11318598E-03 | -4.3326723 | 0.61180550E-01 |
43 | 4 | 32.288109 | 0.93328928E-03 | 21.015642 | -0.41263319 |
44 | 3 | -109.70522 | 0.20484795E-02 | -54.784283 | 1.4932205 |
45 | 2 | 195.62339 | 0.11595496E-02 | 77.105128 | -2.8767741 |
46 | 1 | -170.60747 | 0.12450863E-03 | -55.031726 | 2.7358244 |
47 | 0 | 57.057407 | 0.71328115E-06 | 15.596176 | |
48 | 9 | 0.10418955E-14 | 0.45554749E-16 | -0.13285794E-09 | -0.34221686E-17 |
49 | 8 | 0.19498290E-07 | 0.16949498E-12 | 0.35235048E-03 | -0.22170227E-09 |
50 | 7 | -0.11480752E-01 | 0.90423087E-08 | -0.21989859E-01 | 0.13054032E-03 |
51 | 6 | 0.38467563 | 0.31853038E-05 | 0.45444290 | -0.45040579E-02 |
52 | 5 | -4.9887746 | 0.12022067E-03 | -4.3055366 | 0.60681782E-01 |
53 | 4 | 32.110117 | 0.99300969E-03 | 20.909427 | -0.41027004 |
54 | 3 | -109.32633 | 0.21828955E-02 | -54.574228 | 1.4877470 |
55 | 2 | 195.24766 | 0.12373115E-02 | 76.912747 | -2.8708078 |
56 | 1 | -170.46860 | 0.13302463E-03 | -54.976289 | 2.7333905 |
57 | 0 | 57.057407 | 0.76310210E-06 | 15.605744 | |
58 | 9 | -0.19728226E-15 | 0.38070760E-16 | -0.14134637E-09 | 0.10329039E-17 |
59 | 8 | 0.20696804E-07 | 0.14765672E-12 | 0.36530744E-03 | -0.23532978E-09 |
60 | 7 | -0.11868633E-01 | 0.77667999E-08 | -0.22548754E-01 | 0.13495068E-03 |
61 | 6 | 0.39521686 | 0.27204939E-05 | 0.46345169 | -0.46283129E-02 |
62 | 5 | -5.0916664 | 0.10217830E-03 | -4.3748670 | 0.61957574E-01 |
63 | 4 | 32.565369 | 0.84029717E-03 | 21.180735 | -0.41631434 |
64 | 3 | -110.29532 | 0.18400486E-02 | -55.110745 | 1.5017457 |
65 | 2 | 196.20849 | 0.10394005E-02 | 77.404245 | -2.8860650 |
66 | 1 | -170.82368 | 0.11139293E-03 | -55.118150 | 2.7396138 |
67 | 0 | 57.057407 | 0.63685742E-06 | 15.581450 | |
68 | 9 | 0.13059652E-14 | 0.41030072E-16 | -0.13816519E-09 | -0.47111965E-17 |
69 | 8 | 0.20247126E-07 | 0.15597406E-12 | 0.36047671E-03 | -0.23021680E-09 |
70 | 7 | -0.11724123E-01 | 0.82470298E-08 | -0.22340566E-01 | 0.13330755E-03 |
71 | 6 | 0.39128975 | 0.28947446E-05 | 0.46009809 | -0.45820219E-02 |
72 | 5 | -5.0533361 | 0.10891817E-03 | -4.3490697 | 0.61482301E-01 |
73 | 4 | 32.395785 | 0.89717001E-03 | 21.079809 | -0.41406279 |
74 | 3 | -109.93440 | 0.19673976E-02 | -54.911173 | 1.4965315 |
75 | 2 | 195.85064 | 0.11127485E-02 | 77.221372 | -2.8803827 |
76 | 1 | -170.69145 | 0.11939355E-03 | -55.065279 | 2.7372963 |
77 | 0 | 57.057407 | 0.68346468E-06 | 15.590432 | |
78 | 7 | -0.15963512E-14 | -0.15187529E-16 | -0.22427203E-13 | 0.56155309E-15 |
79 | 6 | 0.17983713E-10 | 0.23594901E-11 | 0.52322926E-09 | -0.18637893E-10 |
80 | 5 | -0.60139213E-07 | 0.11510628E-07 | -0.21924491E-05 | 0.17161312E-06 |
81 | 4 | 0.62746279E-04 | 0.43399923E-05 | 0.17681060E-02 | -0.28244642E-03 |
82 | 3 | -0.90508353E-02 | 0.15320797E-03 | -0.21560640 | 0.43341486E-01 |
83 | 2 | 0.12836503 | 0.66328859E-03 | 2.9007871 | -0.61911613 |
84 | 1 | -0.32478029 | 0.41934727E-03 | -7.1379041 | 1.5697129 |
85 | 0 | 0.20664896 | 0.54311639E-05 | 4.4522013 | |
86 | 7 | -0.22427203E-13 | -0.15187529E-16 | -0.15963512E-14 | 0.56155309E-15 |
87 | 6 | 0.52322926E-09 | 0.23594901E-11 | 0.17983713E-10 | -0.18637893E-10 |
88 | 5 | -0.21924491E-05 | 0.11510628E-07 | -0.60139213E-07 | 0.17161312E-06 |
89 | 4 | 0.17681060E-02 | 0.43399923E-05 | 0.62746279E-04 | -0.28244642E-03 |
90 | 3 | -0.21560640 | 0.15320797E-03 | -0.90508353E-02 | 0.43341486E-01 |
91 | 2 | 2.9007871 | 0.66328859E-03 | 0.12836503 | -0.61911613 |
92 | 1 | -7.1379041 | 0.41934727E-03 | -0.32478029 | 1.5697129 |
93 | 0 | 4.4522013 | 0.54311639E-05 | 0.20664896 | |
94 | 7 | -0.52459208E-15 | -0.63961428E-15 | -0.12292524E-09 | -0.35846135E-17 |
95 | 6 | 0.39860198E-02 | 0.96339020E-07 | 0.40499006E-03 | -0.70890431E-04 |
96 | 5 | -0.20832379 | 0.49172556E-04 | -0.20585669E-01 | 0.38489246E-02 |
97 | 4 | 3.5198270 | 0.18993977E-02 | 0.34924834 | -0.69168259E-01 |
98 | 3 | -23.366787 | 0.13311857E-01 | -2.4329538 | 0.50524779 |
99 | 2 | 64.890127 | 0.19943872E-01 | 7.3672511 | -1.5911358 |
100 | 1 | -76.040094 | 0.56792084E-02 | -9.5568013 | 2.1361271 |
101 | 0 | 31.242244 | 0.96490710E-04 | 4.3344156 | |
102 | 7 | -0.98583555E-09 | -0.79843648E-16 | 0.12056005E-14 | 0.46388562E-17 |
103 | 6 | 0.11736010E-04 | 0.80964505E-08 | 0.31724491E-02 | -0.26613162E-04 |
104 | 5 | -0.85155955E-03 | 0.48044989E-05 | -0.22273424 | 0.19474091E-02 |
105 | 4 | 0.19629464E-01 | 0.21887653E-03 | 4.8130477 | -0.45106395E-01 |
106 | 3 | -0.17247723 | 0.17421542E-02 | -37.928201 | 0.39762344 |
107 | 2 | 0.61254091 | 0.29000861E-02 | 116.30250 | -1.4155123 |
108 | 1 | -0.88416489 | 0.88473762E-03 | -143.80049 | 2.0472841 |
109 | 0 | 0.43108349 | 0.21254961E-04 | 60.838472 | |
110 | 7 | -0.98583555E-09 | -0.79843648E-16 | 0.12056005E-14 | 0.46388562E-17 |
111 | 6 | 0.11736010E-04 | 0.80964505E-08 | 0.31724491E-02 | -0.26613162E-04 |
112 | 5 | -0.85155955E-03 | 0.48044989E-05 | -0.22273424 | 0.19474091E-02 |
113 | 4 | 0.19629464E-01 | 0.21887653E-03 | 4.8130477 | -0.45106395E-01 |
114 | 3 | -0.17247723 | 0.17421542E-02 | -37.928201 | 0.39762344 |
115 | 2 | 0.61254091 | 0.29000861E-02 | 116.30250 | -1.4155123 |
116 | 1 | -0.88416489 | 0.88473762E-03 | -143.80049 | 2.0472841 |
117 | 0 | 0.43108349 | 0.21254961E-04 | 60.838472 | |
118 | 7 | -0.98583555E-09 | -0.79843648E-16 | 0.12056005E-14 | 0.46388562E-17 |
119 | 6 | 0.11736010E-04 | 0.80964505E-08 | 0.31724491E-02 | -0.26613162E-04 |
120 | 5 | -0.85155955E-03 | 0.48044989E-05 | -0.22273424 | 0.19474091E-02 |
121 | 4 | 0.19629464E-01 | 0.21887653E-03 | 4.8130477 | -0.45106395E-01 |
122 | 3 | -0.17247723 | 0.17421542E-02 | -37.928201 | 0.39762344 |
123 | 2 | 0.61254091 | 0.29000861E-02 | 116.30250 | -1.4155123 |
124 | 1 | -0.88416489 | 0.88473762E-03 | -143.80049 | 2.0472841 |
125 | 0 | 0.43108349 | 0.21254961E-04 | 60.838472 | |
126 | 7 | -0.98583555E-09 | -0.79843648E-16 | 0.12056005E-14 | 0.46388562E-17 |
127 | 6 | 0.11736010E-04 | 0.80964505E-08 | 0.31724491E-02 | -0.26613162E-04 |
128 | 5 | -0.85155955E-03 | 0.48044989E-05 | -0.22273424 | 0.19474091E-02 |
129 | 4 | 0.19629464E-01 | 0.21887653E-03 | 4.8130477 | -0.45106395E-01 |
130 | 3 | -0.17247723 | 0.17421542E-02 | -37.928201 | 0.39762344 |
131 | 2 | 0.61254091 | 0.29000861E-02 | 116.30250 | -1.4155123 |
132 | 1 | -0.88416489 | 0.88473762E-03 | -143.80049 | 2.0472841 |
133 | 0 | 0.43108349 | 0.21254961E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.3856_SHGC_0.4 | 37 | 1 | VerySmooth | 2.191 | 2.191 | 1.000 | 0.401 | ||
2 | RESWINDOW_U_0.3856_SHGC_0.4 | 38 | 1 | VerySmooth | 2.191 | 2.191 | 1.000 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER | SpectralAverage | 3.40174E-002 | 0.31435 | 0.47878 | 0.47878 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11969 | 1.00000 | No | |
2 | RESIDENTIAL WINDOW GLAZING LAYER | SpectralAverage | 3.40174E-002 | 0.31435 | 0.47878 | 0.47878 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11969 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 7 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | CAFE_FLR_1 | 1 | 0 |
2 | LOBBY_FLR_1 | 1 | 0 |
3 | BANQUET_FLR_6 | 1 | 0 |
4 | DINING_FLR_6 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | CAFE_FLR_1 | 0 | |
2 | LOBBY_FLR_1 | 0 | |
3 | BANQUET_FLR_6 | 0 | |
4 | DINING_FLR_6 | 0 |
Number of Refrigeration Compressor Racks | |
1 | 2 |
Compressor Rack Name | # Refrigerated Cases Connected | # WalkIn Coolers Connected | Heat Rejection Location | Condenser Type | COP | |
1 | RACK1 | 1 | 0 | Zone | Air-Cooled | 1.500 |
2 | RACK2 | 1 | 0 | Zone | Air-Cooled | 3.000 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWH BOOSTER E WATER HEATER | 2.2712E-002 | 8000.0 | 1.240 | 1.1473 |
2 | WaterHeater:Mixed | SWH LAUNDRY G WATER HEATER | 1.1356 | 163316.0 | 0.576 | 0.5074 |
3 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 2.2712 | 175842.6 | 0.263 | 2.9576E-002 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BASEMENT_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
2 | BASEMENT_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
3 | BASEMENT_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
4 | BASEMENT_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
5 | BASEMENT_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
6 | BASEMENT_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
7 | BASEMENT_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
8 | BASEMENT_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
9 | BASEMENT_CEILING_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
10 | BASEMENT_CEILING_5 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
11 | BASEMENT_CEILING_6 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
12 | BASEMENT_CEILING_7 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
13 | BASEMENT_CEILING_8 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
14 | BASEMENT_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
15 | RETAIL_1_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 4 | No | No |
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 1 | No | No |
17 | RETAIL_1_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 3 | No | No |
18 | RETAIL_1_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
19 | RETAIL_1_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
20 | RETAIL_1_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
21 | RETAIL_1_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
23 | RETAIL_2_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
25 | RETAIL_2_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
26 | RETAIL_2_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
27 | RETAIL_2_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
28 | RETAIL_2_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
29 | RETAIL_2_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
31 | MECH_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
32 | MECH_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
33 | MECH_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
34 | MECH_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
35 | MECH_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
36 | MECH_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
37 | MECH_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
38 | STORAGE_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
40 | STORAGE_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
41 | STORAGE_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
42 | STORAGE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
43 | STORAGE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
44 | STORAGE_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
45 | STORAGE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
46 | LAUNDRY_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
47 | LAUNDRY_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
49 | LAUNDRY_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
50 | LAUNDRY_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
51 | LAUNDRY_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
52 | LAUNDRY_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
54 | CAFE_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 3 | No | No |
55 | CAFE_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
56 | CAFE_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 4 | No | No |
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 1 | No | No |
58 | CAFE_FLR_1_WALL_1_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
59 | CAFE_FLR_1_WALL_2_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
60 | CAFE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
61 | CAFE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
62 | CAFE_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
63 | CAFE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
64 | LOBBY_FLR_1_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
67 | LOBBY_FLR_1_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
68 | LOBBY_FLR_1_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 1 | No | No |
70 | LOBBY_FLR_1_WALL_1_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
71 | LOBBY_FLR_1_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
72 | LOBBY_FLR_1_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
73 | LOBBY_FLR_1_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
74 | LOBBY_FLR_1_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
75 | LOBBY_FLR_1_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
76 | LOBBY_FLR_1_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
77 | LOBBY_FLR_1_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
78 | LOBBY_FLR_1_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
79 | LOBBY_FLR_1_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
80 | LOBBY_FLR_1_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
81 | LOBBY_FLR_1_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
82 | LOBBY_FLR_1_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
83 | LOBBY_FLR_1_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
84 | LOBBY_FLR_1_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
85 | LOBBY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
86 | ROOM_1_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
88 | ROOM_1_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
90 | ROOM_1_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
91 | ROOM_1_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
92 | ROOM_1_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
93 | ROOM_1_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
94 | ROOM_1_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
95 | ROOM_2_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
97 | ROOM_2_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
99 | ROOM_2_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
100 | ROOM_2_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
101 | ROOM_2_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
102 | ROOM_2_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
103 | ROOM_2_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
109 | ROOM_3_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
110 | ROOM_3_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
117 | ROOM_4_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
118 | ROOM_4_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
120 | ROOM_5_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
122 | ROOM_5_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
124 | ROOM_5_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
125 | ROOM_5_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
126 | ROOM_5_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
127 | ROOM_5_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
128 | ROOM_5_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
129 | ROOM_6_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
131 | ROOM_6_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
133 | ROOM_6_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
134 | ROOM_6_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
135 | ROOM_6_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
136 | ROOM_6_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
137 | ROOM_6_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
138 | CORRIDOR_FLR_3_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
147 | CORRIDOR_FLR_3_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
148 | CORRIDOR_FLR_3_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
149 | CORRIDOR_FLR_3_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
150 | CORRIDOR_FLR_3_WALL_4_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
152 | CORRIDOR_FLR_3_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
153 | CORRIDOR_FLR_3_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
154 | CORRIDOR_FLR_3_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
155 | CORRIDOR_FLR_3_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
156 | CORRIDOR_FLR_3_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
157 | CORRIDOR_FLR_3_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
158 | CORRIDOR_FLR_3_FLOOR_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
159 | CORRIDOR_FLR_3_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
160 | CORRIDOR_FLR_3_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
161 | CORRIDOR_FLR_3_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
163 | ROOM_1_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
165 | ROOM_1_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
167 | ROOM_1_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
168 | ROOM_1_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
169 | ROOM_1_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
170 | ROOM_1_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
171 | ROOM_1_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
172 | ROOM_2_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
174 | ROOM_2_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
176 | ROOM_2_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
177 | ROOM_2_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
178 | ROOM_2_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
179 | ROOM_2_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
180 | ROOM_2_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 3 | No | No |
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 2 | No | No |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
186 | ROOM_3_MULT9_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
187 | ROOM_3_MULT9_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
189 | BANQUET_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
191 | BANQUET_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
192 | BANQUET_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
193 | BANQUET_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
194 | BANQUET_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
195 | BANQUET_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
196 | BANQUET_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
197 | DINING_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
198 | DINING_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
199 | DINING_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
200 | DINING_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
201 | DINING_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
202 | DINING_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
203 | DINING_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
204 | DINING_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
205 | KITCHEN_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
207 | KITCHEN_FLR_6_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
212 | KITCHEN_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
213 | KITCHEN_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
214 | KITCHEN_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
215 | KITCHEN_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
216 | KITCHEN_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
217 | CORRIDOR_FLR_6_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
224 | CORRIDOR_FLR_6_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
226 | CORRIDOR_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
227 | CORRIDOR_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
228 | CORRIDOR_FLR_6_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
229 | CORRIDOR_FLR_6_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
230 | CORRIDOR_FLR_6_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
231 | CORRIDOR_FLR_6_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
232 | CORRIDOR_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
233 | CORRIDOR_FLR_6_CEILING_1 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
234 | CORRIDOR_FLR_6_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | RETAIL_1_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 3.921E-002 | 5.846E-004 | 2.885E-004 | 0.531 | 1.000 | 0.000 | 0.000 | 0.000 |
2 | RETAIL_2_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 1.513E-002 | 1.949E-004 | 5.306E-004 | 0.177 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | MECH_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | MECH_FLR_1 | 164.24 | 2.7 | 3.577E-002 | 2.178E-004 | 5.696E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
4 | STORAGE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 2.064E-002 | 2.178E-004 | 4.726E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | LAUNDRY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 4.884E-002 | 6.258E-004 | 5.569E-004 | 0.569 | 1.000 | 0.000 | 0.000 | 0.000 |
6 | CAFE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 8.667E-002 | 4.589E-004 | 2.527E-004 | 0.417 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | LOBBY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 0.248 | 1.893E-004 | 3.620E-004 | 0.172 | 1.000 | 0.000 | 0.000 | 0.000 |
8 | ROOM_1_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 5.696E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | ROOM_2_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 5.696E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
10 | ROOM_3_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 6.349E-003 | 2.589E-004 | 5.696E-004 | 0.306 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | ROOM_4_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 6.350E-003 | 2.589E-004 | 5.696E-004 | 0.306 | 1.000 | 0.000 | 0.000 | 0.000 |
12 | ROOM_5_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 5.696E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | ROOM_6_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 5.696E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
14 | CORRIDOR_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_3 | 389.40 | 21.0 | 2.751E-002 | 7.066E-005 | 5.696E-004 | 8.345E-002 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | ROOM_1_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 2.881E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
16 | ROOM_2_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 2.275E-002 | 5.831E-004 | 2.881E-004 | 0.689 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | ROOM_3_MULT9_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 1.164E-002 | 4.746E-004 | 2.589E-004 | 0.561 | 1.000 | 0.000 | 0.000 | 0.000 |
18 | BANQUET_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 5.556E-002 | 1.675E-004 | 1.295E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | DINING_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | DINING_FLR_6 | 331.66 | 249.9 | 5.556E-002 | 1.675E-004 | 1.295E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
20 | KITCHEN_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 4.974E-002 | 4.815E-004 | 2.609E-004 | 0.569 | 1.000 | 0.000 | 0.000 | 0.000 |
21 | CORRIDOR_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_6 | 412.12 | 22.2 | 4.868E-002 | 1.181E-004 | 9.784E-005 | 0.140 | 1.000 | 0.000 | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | ROOM_1_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
2 | ROOM_2_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
3 | ROOM_3_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
4 | ROOM_4_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
5 | ROOM_5_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_5_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
6 | ROOM_6_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_6_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
7 | ROOM_1_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
8 | ROOM_2_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
9 | ROOM_3_MULT9_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BASEMENT | Mixing/Well-Stirred |
2 | RETAIL_1_FLR_1 | Mixing/Well-Stirred |
3 | RETAIL_2_FLR_1 | Mixing/Well-Stirred |
4 | MECH_FLR_1 | Mixing/Well-Stirred |
5 | STORAGE_FLR_1 | Mixing/Well-Stirred |
6 | LAUNDRY_FLR_1 | Mixing/Well-Stirred |
7 | CAFE_FLR_1 | Mixing/Well-Stirred |
8 | LOBBY_FLR_1 | Mixing/Well-Stirred |
9 | ROOM_1_FLR_3 | Mixing/Well-Stirred |
10 | ROOM_2_FLR_3 | Mixing/Well-Stirred |
11 | ROOM_3_MULT19_FLR_3 | Mixing/Well-Stirred |
12 | ROOM_4_MULT19_FLR_3 | Mixing/Well-Stirred |
13 | ROOM_5_FLR_3 | Mixing/Well-Stirred |
14 | ROOM_6_FLR_3 | Mixing/Well-Stirred |
15 | CORRIDOR_FLR_3 | Mixing/Well-Stirred |
16 | ROOM_1_FLR_6 | Mixing/Well-Stirred |
17 | ROOM_2_FLR_6 | Mixing/Well-Stirred |
18 | ROOM_3_MULT9_FLR_6 | Mixing/Well-Stirred |
19 | BANQUET_FLR_6 | Mixing/Well-Stirred |
20 | DINING_FLR_6 | Mixing/Well-Stirred |
21 | KITCHEN_FLR_6 | Mixing/Well-Stirred |
22 | CORRIDOR_FLR_6 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT1 | 0.1437 |
2 | Clear Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT2 | 7.1011E-002 |
3 | Clear Turbid Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT1 | 0.1609 |
4 | Clear Turbid Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT2 | 7.9327E-002 |
5 | Intermediate Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT1 | 0.1049 |
6 | Intermediate Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT2 | 4.0551E-002 |
7 | Overcast Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT1 | 4.2077E-002 |
8 | Overcast Sky | 01/21 | LOBBY_FLR_1_DAYLCTRL | LOBBY_FLR_1 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_DAYLREFPT2 | 1.3979E-002 |
9 | Clear Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT1 | 0.1633 |
10 | Clear Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT2 | 8.6041E-002 |
11 | Clear Turbid Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT1 | 0.1834 |
12 | Clear Turbid Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT2 | 9.5907E-002 |
13 | Intermediate Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT1 | 0.1161 |
14 | Intermediate Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT2 | 5.0830E-002 |
15 | Overcast Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT1 | 4.7248E-002 |
16 | Overcast Sky | 01/21 | CAFE_FLR_1_DAYLCTRL | CAFE_FLR_1 | CAFE_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_DAYLREFPT2 | 1.9114E-002 |
17 | Clear Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT1 | 3.4931E-002 |
18 | Clear Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT2 | 2.0129E-002 |
19 | Clear Turbid Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT1 | 2.6801E-002 |
20 | Clear Turbid Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT2 | 1.5154E-002 |
21 | Intermediate Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT1 | 2.5863E-002 |
22 | Intermediate Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT2 | 1.0352E-002 |
23 | Overcast Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT1 | 4.1419E-002 |
24 | Overcast Sky | 01/21 | DINING_FLR_6_DAYLCTRL | DINING_FLR_6 | DINING_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_DAYLREFPT2 | 1.4687E-002 |
25 | Clear Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT1 | 3.4931E-002 |
26 | Clear Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT2 | 2.0129E-002 |
27 | Clear Turbid Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT1 | 2.6801E-002 |
28 | Clear Turbid Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT2 | 1.5154E-002 |
29 | Intermediate Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT1 | 2.5863E-002 |
30 | Intermediate Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT2 | 1.0352E-002 |
31 | Overcast Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT1 | 4.1419E-002 |
32 | Overcast Sky | 01/21 | BANQUET_FLR_6_DAYLCTRL | BANQUET_FLR_6 | BANQUET_FLR_6_WALL_NORTH_WINDOW | BANQUET_FLR_6_DAYLREFPT2 | 1.4687E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BASEMENT | Cooling | 34629.43520 | 34629.43520 | 2.51728 | 2.51728 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 28.94267 | 1.41140E-002 | 1978.83018 | 106.49900 | 0.85446 | 0.00000 |
2 | BASEMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 0.85446 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | -10.70000 | 1.50390E-003 | 1978.83018 | 106.49900 | 0.85446 | 0.00000 |
3 | RETAIL_1_FLR_1 | Cooling | 5343.95247 | 5343.95247 | 0.38852 | 0.38852 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:10:00 | 31.79167 | 1.41191E-002 | 67.07136 | 10.82900 | 7.92179E-002 | 0.00000 |
4 | RETAIL_1_FLR_1 | Heating | 3020.74513 | 3020.74513 | 0.12953 | 0.12953 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 67.07136 | 10.82900 | 7.92179E-002 | 0.00000 |
5 | RETAIL_2_FLR_1 | Cooling | 3305.70335 | 3305.70335 | 0.24033 | 0.24033 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 31.73000 | 1.41190E-002 | 77.66889 | 12.54000 | 9.17347E-002 | 0.00000 |
6 | RETAIL_2_FLR_1 | Heating | 1052.62825 | 1052.62825 | 4.51389E-002 | 9.17347E-002 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 77.66889 | 12.54000 | 9.17347E-002 | 0.00000 |
7 | MECH_FLR_1 | Cooling | 3212.84884 | 3212.84884 | 0.23353 | 0.23353 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | 31.45867 | 1.41185E-002 | 164.24319 | 2.65200 | 0.00000 | 0.00000 |
8 | MECH_FLR_1 | Heating | 1954.30633 | 1954.30633 | 8.38043E-002 | 8.38043E-002 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 164.24319 | 2.65200 | 0.00000 | 0.00000 |
9 | STORAGE_FLR_1 | Cooling | 1557.05127 | 1557.05127 | 0.11318 | 0.11318 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 32.02600 | 1.41195E-002 | 94.75927 | 2.04000 | 5.77652E-002 | 0.00000 |
10 | STORAGE_FLR_1 | Heating | 1180.20718 | 1180.20718 | 5.06095E-002 | 5.77652E-002 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 94.75927 | 2.04000 | 5.77652E-002 | 0.00000 |
11 | LAUNDRY_FLR_1 | Cooling | 44902.36231 | 44902.36231 | 3.26417 | 3.26417 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 32.10000 | 1.41196E-002 | 78.03947 | 8.40000 | 0.00000 | 0.00000 |
12 | LAUNDRY_FLR_1 | Heating | 2592.61910 | 2592.61910 | 0.11117 | 0.11117 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 78.03947 | 8.40000 | 0.00000 | 0.00000 |
13 | CAFE_FLR_1 | Cooling | 21548.00079 | 21548.00079 | 1.56784 | 1.56784 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:10:00 | 31.79167 | 1.41191E-002 | 188.86188 | 142.30000 | 0.67639 | 0.00000 |
14 | CAFE_FLR_1 | Heating | 7544.96757 | 7544.96757 | 0.32353 | 0.67639 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 188.86188 | 142.30000 | 0.67639 | 0.00000 |
15 | LOBBY_FLR_1 | Cooling | 65473.02007 | 65473.02007 | 4.76127 | 4.76127 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 31.85333 | 1.41192E-002 | 1308.18612 | 422.43500 | 1.89399 | 0.00000 |
16 | LOBBY_FLR_1 | Heating | 18132.10487 | 18132.10487 | 0.77754 | 1.89399 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 1308.18612 | 422.43500 | 1.89399 | 0.00000 |
17 | ROOM_1_FLR_3 | Cooling | 11633.21607 | 11633.21607 | 1.13957 | 1.13957 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 31.36000 | 1.41183E-002 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
18 | ROOM_1_FLR_3 | Heating | 6925.54997 | 6925.54997 | 0.29871 | 0.29871 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
19 | ROOM_2_FLR_3 | Cooling | 11276.96711 | 11276.96711 | 1.10468 | 1.10468 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 31.26133 | 1.41181E-002 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
20 | ROOM_2_FLR_3 | Heating | 6944.75921 | 6944.75921 | 0.29954 | 0.29954 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
21 | ROOM_3_MULT19_FLR_3 | Cooling | 66672.54881 | 66672.54881 | 6.53063 | 6.53063 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 31.85333 | 1.41192E-002 | 24.52384 | 1.50000 | 0.83707 | 0.00000 |
22 | ROOM_3_MULT19_FLR_3 | Heating | 39426.74952 | 39426.74952 | 1.70061 | 1.70061 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 24.52384 | 1.50000 | 0.83707 | 0.00000 |
23 | ROOM_4_MULT19_FLR_3 | Cooling | 58807.60389 | 58807.60389 | 5.76070 | 5.76070 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 32.10000 | 1.41196E-002 | 24.53055 | 1.50000 | 0.83730 | 0.00000 |
24 | ROOM_4_MULT19_FLR_3 | Heating | 39798.65659 | 39798.65659 | 1.71665 | 1.71665 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 24.53055 | 1.50000 | 0.83730 | 0.00000 |
25 | ROOM_5_FLR_3 | Cooling | 10598.29248 | 10598.29248 | 1.03820 | 1.03820 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:40:00 | 28.86867 | 1.41138E-002 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
26 | ROOM_5_FLR_3 | Heating | 6886.44083 | 6886.44083 | 0.29703 | 0.29703 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
27 | ROOM_6_FLR_3 | Cooling | 10288.15957 | 10288.15957 | 1.00782 | 1.00782 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 28.44933 | 1.41131E-002 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
28 | ROOM_6_FLR_3 | Heating | 6905.66647 | 6905.66647 | 0.29786 | 0.29786 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
29 | CORRIDOR_FLR_3 | Cooling | 20691.81162 | 20691.81162 | 1.50410 | 1.50410 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 32.10000 | 1.41196E-002 | 389.40468 | 20.95700 | 0.47476 | 0.00000 |
30 | CORRIDOR_FLR_3 | Heating | 10902.84151 | 10902.84151 | 0.46754 | 0.47476 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 389.40468 | 20.95700 | 0.47476 | 0.00000 |
31 | ROOM_1_FLR_6 | Cooling | 3055.32523 | 3055.32523 | 0.29930 | 0.29930 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 31.36000 | 1.41183E-002 | 39.02202 | 1.50000 | 1.54338E-002 | 0.00000 |
32 | ROOM_1_FLR_6 | Heating | 2086.05700 | 2086.05700 | 8.99762E-002 | 8.99762E-002 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.02202 | 1.50000 | 1.54338E-002 | 0.00000 |
33 | ROOM_2_FLR_6 | Cooling | 2955.59954 | 2955.59954 | 0.28953 | 0.28953 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 31.26133 | 1.41181E-002 | 39.01745 | 1.50000 | 1.54319E-002 | 0.00000 |
34 | ROOM_2_FLR_6 | Heating | 2092.48648 | 2092.48648 | 9.02535E-002 | 9.02535E-002 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 39.01745 | 1.50000 | 1.54319E-002 | 0.00000 |
35 | ROOM_3_MULT9_FLR_6 | Cooling | 13968.14424 | 13968.14424 | 1.36832 | 1.36832 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 31.85333 | 1.41192E-002 | 24.53055 | 1.50000 | 9.91540E-002 | 0.00000 |
36 | ROOM_3_MULT9_FLR_6 | Heating | 9911.94272 | 9911.94272 | 0.42753 | 0.42753 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | -10.70000 | 1.50390E-003 | 24.53055 | 1.50000 | 9.91540E-002 | 0.00000 |
37 | BANQUET_FLR_6 | Cooling | 29903.24138 | 29903.24138 | 2.17637 | 2.17637 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 32.10000 | 1.41196E-002 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
38 | BANQUET_FLR_6 | Heating | 6670.78827 | 6670.78827 | 0.28606 | 1.18780 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
39 | DINING_FLR_6 | Cooling | 31337.93064 | 31337.93064 | 2.28075 | 2.28075 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 32.10000 | 1.41196E-002 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
40 | DINING_FLR_6 | Heating | 6816.63662 | 6816.63662 | 0.29231 | 1.18780 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
41 | KITCHEN_FLR_6 | Cooling | 31140.20697 | 31140.20697 | 2.26954 | 2.26954 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:30:00 | 31.43400 | 1.41184E-002 | 103.30446 | 22.23800 | 0.36735 | 0.00000 |
42 | KITCHEN_FLR_6 | Heating | 2545.68237 | 2545.68237 | 0.10915 | 0.36735 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | -10.70000 | 1.50390E-003 | 103.30446 | 22.23800 | 0.36735 | 0.00000 |
43 | CORRIDOR_FLR_6 | Cooling | 10656.07318 | 10656.07318 | 0.77460 | 0.77460 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 31.97667 | 1.41194E-002 | 412.12471 | 22.18000 | 0.12562 | 0.00000 |
44 | CORRIDOR_FLR_6 | Heating | 6871.55890 | 6871.55890 | 0.29467 | 0.29467 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | -10.70000 | 1.50390E-003 | 412.12471 | 22.18000 | 0.12562 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | VAV WITH REHEAT | Cooling | Sensible | 411394.29 | 21.96881 | 21.96881 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | VAV WITH REHEAT | Heating | Sensible | 245598.38 | 7.41122 | 7.41122 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 |
3 | FLR_3_DOAS | Cooling | Sensible | 47880.67 | 17.42703 | 2.05125 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | FLR_3_DOAS | Heating | Sensible | 67975.66 | 5.21818 | 2.05125 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.51728 |
2 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.59901 |
3 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
4 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.32912 |
5 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
6 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.36051E-004 |
8 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.13651E-005 |
9 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.32912 |
10 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
11 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
12 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 7014.40575 |
13 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.13651E-005 |
14 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 146.27334 |
15 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.38852 |
16 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13155 |
17 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
18 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.20514 |
19 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
20 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
21 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.89631E-003 |
22 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.58869E-005 |
23 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.20514 |
24 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
25 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
26 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 4102.09207 |
27 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.58869E-005 |
28 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 100.28749 |
29 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.24033 |
30 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24626 |
31 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
32 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12689 |
33 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.65670 |
34 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
35 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.54714E-003 |
36 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.50610E-005 |
37 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.12689 |
38 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
40 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 1721.56908 |
41 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.50610E-005 |
42 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 39.11164 |
43 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.23353 |
44 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.53592 |
45 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
46 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12330 |
47 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
48 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
49 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.10926E-004 |
50 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.27823E-005 |
51 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.12330 |
52 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
53 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
54 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 2604.15424 |
55 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.27823E-005 |
56 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 64.53463 |
57 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.11318 |
58 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.63800 |
59 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
60 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 5.97574E-002 |
61 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
62 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.97181E-004 |
64 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.30803E-005 |
65 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.97574E-002 |
66 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
67 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
68 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 1495.16344 |
69 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.30803E-005 |
70 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 38.90705 |
71 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.26417 |
72 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 7.22921E-002 |
73 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
74 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.72348 |
75 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
76 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
77 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.09136E-002 |
78 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.02131E-004 |
79 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.72348 |
80 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
81 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
82 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11674.16877 |
83 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.02131E-004 |
84 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 247.07997 |
85 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.56784 |
86 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.17907E-002 |
87 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
88 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.82782 |
89 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
90 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 4.15075E-003 |
92 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.04188E-004 |
93 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.82782 |
94 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
96 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11909.28942 |
97 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.04188E-004 |
98 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 273.00688 |
99 | Fan:ZoneExhaust | LOBBY_FLR_1 EXHAUST FAN | User-Specified Maximum Flow Rate [m3/s] | 0.00000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 4.76127 |
101 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20936 |
102 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
103 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.51395 |
104 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.55830 |
105 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
106 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.81980E-003 |
107 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.74573E-004 |
108 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.51395 |
109 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
110 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
111 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 31385.41485 |
112 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.74573E-004 |
113 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 704.71792 |
114 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_1_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17350E-002 |
115 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.13957 |
116 | Fan:OnOff | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.13957 |
117 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.05854E-005 |
118 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.64928E-004 |
119 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68268 |
120 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
121 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.66703E-003 |
122 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
123 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
124 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.64928E-004 |
125 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.13957 |
126 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 6925.28435 |
127 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.05854E-005 |
128 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 197.90598 |
129 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_2_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17278E-002 |
130 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.10468 |
131 | Fan:OnOff | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.10468 |
132 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.07535E-005 |
133 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.51328E-004 |
134 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68267 |
135 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
136 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.67231E-003 |
137 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
138 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
139 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.51328E-004 |
140 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.10468 |
141 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 6944.49289 |
142 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.07535E-005 |
143 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 198.45475 |
144 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_3_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.83707 |
145 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.53063 |
146 | Fan:OnOff | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 6.53063 |
147 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 3.44918E-004 |
148 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 2.61383E-003 |
149 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68341 |
150 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
151 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.59586E-003 |
152 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
153 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
154 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 2.61383E-003 |
155 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 6.53063 |
156 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 39426.22660 |
157 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.44918E-004 |
158 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1126.67507 |
159 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_4_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.83730 |
160 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 5.76070 |
161 | Fan:OnOff | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 5.76070 |
162 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 3.48171E-004 |
163 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 2.46429E-003 |
164 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68250 |
165 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
166 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.84827E-003 |
167 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
168 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
169 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 2.46429E-003 |
170 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 5.76070 |
171 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 39798.12925 |
172 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.48171E-004 |
173 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1137.30017 |
174 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_5_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17350E-002 |
175 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.03820 |
176 | Fan:OnOff | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.03820 |
177 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.02433E-005 |
178 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.25498E-004 |
179 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68264 |
180 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
181 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.68406E-003 |
182 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
183 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
184 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.25498E-004 |
185 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.03820 |
186 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 6886.17659 |
187 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.02433E-005 |
188 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 196.78869 |
189 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_6_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17278E-002 |
190 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.00782 |
191 | Fan:OnOff | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.00782 |
192 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.04115E-005 |
193 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.13667E-004 |
194 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68263 |
195 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
196 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.68969E-003 |
197 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
198 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
199 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.13667E-004 |
200 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.00782 |
201 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 6905.40154 |
202 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.04115E-005 |
203 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 197.33793 |
204 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.50410 |
205 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.78911 |
206 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
207 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.79417 |
208 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
209 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
210 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 4.82821E-004 |
211 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.32021E-004 |
212 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.79417 |
213 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
214 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
215 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 15090.80323 |
216 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.32021E-004 |
217 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 364.60674 |
218 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_1_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.54338E-002 |
219 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.29930 |
220 | Fan:OnOff | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.29930 |
221 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 1.82491E-005 |
222 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 1.21853E-004 |
223 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68269 |
224 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
225 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.65924E-003 |
226 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
227 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
228 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 1.21853E-004 |
229 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.29930 |
230 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 2085.97937 |
231 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.82491E-005 |
232 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 59.60884 |
233 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_2_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.54319E-002 |
234 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.28953 |
235 | Fan:OnOff | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.28953 |
236 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 1.83053E-005 |
237 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 1.18045E-004 |
238 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68269 |
239 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
240 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.66458E-003 |
241 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
242 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
243 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 1.18045E-004 |
244 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.28953 |
245 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 2092.40863 |
246 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.83053E-005 |
247 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 59.79252 |
248 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_3_MULT9_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 9.91540E-002 |
249 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.36832 |
250 | Fan:OnOff | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.36832 |
251 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 8.67114E-005 |
252 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 5.65971E-004 |
253 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 21.68252 |
254 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
255 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.71872E-003 |
256 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
257 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
258 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 5.65971E-004 |
259 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.36832 |
260 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 9911.64573 |
261 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.67114E-005 |
262 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 283.23301 |
263 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.17637 |
264 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11612 |
265 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
266 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.14912 |
267 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
268 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
269 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.28105E-003 |
270 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.11376E-004 |
271 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.14912 |
272 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
273 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
274 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 12730.97710 |
275 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.11376E-004 |
276 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 281.60773 |
277 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.28075 |
278 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11081 |
279 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
280 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.20424 |
281 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
282 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
283 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.43841E-003 |
284 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.15196E-004 |
285 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.20424 |
286 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
287 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
288 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13167.56468 |
289 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.15196E-004 |
290 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 290.82146 |
291 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.26954 |
292 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 6.23846E-002 |
293 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
294 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.19832 |
295 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.52800 |
296 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
297 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.09847E-002 |
298 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.74275E-005 |
299 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.19832 |
300 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
301 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
302 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 8850.44420 |
303 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.74275E-005 |
304 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 188.47129 |
305 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.77460 |
306 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.40542 |
307 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.52800 |
308 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.40899 |
309 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
310 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
311 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.39760E-004 |
312 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.89871E-005 |
313 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.40899 |
314 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
315 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
316 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 9028.70722 |
317 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.89871E-005 |
318 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 226.38194 |
319 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 11.66429 |
320 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 11.66429 |
321 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 22.09146 |
322 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 11.66429 |
323 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 21.96881 |
324 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 21.96881 |
325 | AirLoopHVAC | VAV WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
326 | AirLoopHVAC | VAV WITH REHEAT | Calculated Heating Air Flow Ratio [] | 0.53095 |
327 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.05132 |
328 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.05132 |
329 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.05132 |
330 | AirLoopHVAC | FLR_3_DOAS | Adjusted Heating Design Air Flow Rate [m3/s] | 2.05132 |
331 | AirLoopHVAC | FLR_3_DOAS | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.05132 |
332 | AirLoopHVAC | FLR_3_DOAS | Adjusted Main Design Air Flow Rate [m3/s] | 2.05132 |
333 | AirLoopHVAC | FLR_3_DOAS | User Heating Air Flow Ratio [] | 0.30000 |
334 | AirLoopHVAC | FLR_3_DOAS | Calculated Heating Air Flow Ratio [] | 1.00000 |
335 | AirLoopHVAC | VAV WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 21.96881 |
336 | AirLoopHVAC | FLR_3_DOAS | Design Supply Air Flow Rate [m3/s] | 2.05132 |
337 | Controller:OutdoorAir | VAV WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 21.96881 |
338 | Controller:OutdoorAir | VAV WITH REHEAT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 11.66146 |
339 | HeatExchanger:AirToAir:SensibleAndLatent | VAV WITH REHEAT OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 11.66146 |
340 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Air Temperature [C] | 28.29868 |
341 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
342 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Outlet Air Temperature [C] | 10.98770 |
343 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 1.20376E-002 |
344 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
345 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Coil Load [W] | 706034.17619 |
346 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 2.52179E-002 |
347 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 21.96881 |
348 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size Rated Capacity [W] | 218405.54126 |
349 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.91071E-003 |
350 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 3604.86608 |
351 | Fan:VariableVolume | VAV WITH REHEAT FAN | Design Size Maximum Flow Rate [m3/s] | 21.96881 |
352 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 2.52179E-002 |
353 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 1.88830E-005 |
354 | Controller:WaterCoil | VAV WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.91071E-003 |
355 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.05132 |
356 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.05125 |
357 | HeatExchanger:AirToAir:SensibleAndLatent | FLR_3_DOAS OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.05125 |
358 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Air Temperature [C] | 32.10000 |
359 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
360 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Outlet Air Temperature [C] | 11.93776 |
361 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 1.41196E-002 |
362 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
363 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Coil Load [W] | 86334.70852 |
364 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 3.08368E-003 |
365 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 2.05132 |
366 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size Rated Capacity [W] | 20393.41537 |
367 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.78410E-004 |
368 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 336.60104 |
369 | Fan:ConstantVolume | FLR_3_DOAS FAN | User-Specified Maximum Flow Rate [m3/s] | 2.05125 |
370 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 3.08368E-003 |
371 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Controller Convergence Tolerance | 1.54423E-004 |
372 | Controller:WaterCoil | FLR_3_DOAS_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.78410E-004 |
373 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Flow Rate [m3/s] | 3.59410E-002 |
374 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Power Consumption [W] | 7406.10776 |
375 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 4.29154E-003 |
376 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 0.51498 |
377 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 4.29154E-003 |
378 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 1292.42358 |
379 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Minimum Flow Rate [m3/s] | 0.00000 |
380 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 490549.45562 |
381 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 490549.46000 |
382 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 4.29154E-003 |
383 | PlantLoop | COOLSYS1 | Maximum Loop Flow Rate [m3/s] | 3.59410E-002 |
384 | PlantLoop | COOLSYS1 | Plant Loop Volume [m3] | 4.31292 |
385 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Flow Rate [m3/s] | 3.59410E-002 |
386 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Power Consumption [W] | 5127.49819 |
387 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Chilled Water Flow Rate [m3/s] | 3.59410E-002 |
388 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Capacity [W] | 1006252.24764 |
389 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | User-Specified Reference Capacity [W] | 1006860.85000 |
390 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Condenser Fluid Flow Rate [m3/s] | 114.78214 |
391 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 3.75036E-004 |
392 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 4.50044E-002 |
393 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 3.75036E-004 |
394 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 47.90688 |
395 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 3.75036E-004 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | 7050.63 |
2 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 4119.67 |
3 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 1729.63 |
4 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | 2615.15 |
5 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | 1501.07 |
6 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 11733.62 |
7 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | 11964.56 |
8 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | 31534.20 |
9 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | 7459.11 |
10 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | 7479.80 |
11 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | 42464.95 |
12 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | 42865.45 |
13 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | 7417.00 |
14 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | 7437.70 |
15 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 15156.30 |
16 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | 2246.71 |
17 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | 2253.64 |
18 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | 10675.35 |
19 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | 12792.28 |
20 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | 13231.07 |
21 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | 8895.25 |
22 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 9066.39 |
23 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | 154769.05 |
24 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | 14451.42 |
Component Type | Name | Nominal Total Capacity {W} | Nominal Sensible Capacity {W} | Nominal Latent Capacity {W} | Nominal Sensible Heat Ratio | Nominal Coil UA Value {W/C} | Nominal Coil Surface Area {m2} | |
1 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | 19136.07 | 15414.87 | 3721.20 | 0.81 | 2144.51 | 21.75 |
2 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | 18567.10 | 14951.35 | 3615.75 | 0.81 | 2080.53 | 21.10 |
3 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | 108303.29 | 87656.57 | 20646.72 | 0.81 | 12155.23 | 123.29 |
4 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | 99728.81 | 79418.93 | 20309.88 | 0.80 | 11140.13 | 112.99 |
5 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | 17485.21 | 14069.33 | 3415.88 | 0.80 | 1958.84 | 19.87 |
6 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | 16990.04 | 13665.88 | 3324.16 | 0.80 | 1903.16 | 19.30 |
7 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | 5019.06 | 4045.12 | 973.93 | 0.81 | 562.56 | 5.71 |
8 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | 4859.75 | 3915.35 | 944.40 | 0.81 | 544.64 | 5.52 |
9 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | 23182.44 | 18611.74 | 4570.70 | 0.80 | 2595.36 | 26.32 |
10 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | 639749.20 | 426343.79 | 213405.41 | 0.67 | 75479.46 | 765.55 |
11 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | 63544.84 | 41523.88 | 22020.96 | 0.65 | 7288.25 | 73.92 |
Component Type | Component Name | IPLV in SI Units {W/W} | IPLV in IP Units {Btu/W-h} | |
1 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | 3.93 | 13.40 |
Zone Name | # Surfaces | |
1 | BASEMENT | 14 |
2 | RETAIL_1_FLR_1 | 8 |
3 | RETAIL_2_FLR_1 | 8 |
4 | MECH_FLR_1 | 7 |
5 | STORAGE_FLR_1 | 8 |
6 | LAUNDRY_FLR_1 | 8 |
7 | CAFE_FLR_1 | 10 |
8 | LOBBY_FLR_1 | 22 |
9 | ROOM_1_FLR_3 | 9 |
10 | ROOM_2_FLR_3 | 9 |
11 | ROOM_3_MULT19_FLR_3 | 8 |
12 | ROOM_4_MULT19_FLR_3 | 8 |
13 | ROOM_5_FLR_3 | 9 |
14 | ROOM_6_FLR_3 | 9 |
15 | CORRIDOR_FLR_3 | 25 |
16 | ROOM_1_FLR_6 | 9 |
17 | ROOM_2_FLR_6 | 9 |
18 | ROOM_3_MULT9_FLR_6 | 8 |
19 | BANQUET_FLR_6 | 8 |
20 | DINING_FLR_6 | 8 |
21 | KITCHEN_FLR_6 | 12 |
22 | CORRIDOR_FLR_6 | 19 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BASEMENT_WALL_NORTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_NORTH_CFACTOR | 0.419 | 0.394 | 211.13 | 211.13 | 211.13 | 0.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BASEMENT_WALL_EAST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_EAST_CFACTOR | 0.419 | 0.394 | 55.76 | 55.76 | 55.76 | 90.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | BASEMENT_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_SOUTH_CFACTOR | 0.419 | 0.394 | 211.13 | 211.13 | 211.13 | 180.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BASEMENT_WALL_WEST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_WEST_CFACTOR | 0.419 | 0.394 | 55.76 | 55.76 | 55.76 | 270.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | BASEMENT_FLOOR | Floor | CTF - ConductionTransferFunction | BASEMENT_FLOOR | 2.705 | 1.632 | 1978.83 | 1978.83 | 1978.83 | 0.00 | 180.00 | 86.56 | 22.86 | 0.00 | BASEMENT_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | BASEMENT_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | RETAIL_1_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | BASEMENT_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
8 | BASEMENT_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
9 | BASEMENT_CEILING_4 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
10 | BASEMENT_CEILING_5 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
11 | BASEMENT_CEILING_6 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | CAFE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
12 | BASEMENT_CEILING_7 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 0.00 | 32.99 | 32.99 | 0.00 | LOBBY_FLR_1_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
13 | BASEMENT_CEILING_8 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 219.63 | 219.63 | 219.63 | 90.00 | 0.00 | 14.82 | 14.82 | 0.00 | LOBBY_FLR_1_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
14 | BASEMENT_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3957.66 | 3957.66 | 3957.66 | 0.00 | 90.00 | 3957.66 | 1.00 | 0.00 | BASEMENT_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | RETAIL_1_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 22.63 | 45.89 | 22.63 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | Window | RETAIL_1_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 23.26 | 23.26 | 23.26 | 180.00 | 90.00 | 10.92 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
17 | RETAIL_1_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | RETAIL_1_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | RETAIL_1_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | RETAIL_1_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 67.07 | 67.07 | 67.07 | 0.00 | 180.00 | 11.58 | 5.79 | 0.00 | BASEMENT_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
21 | RETAIL_1_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 7.62E-002 | 0.92 | 4 | ||
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 134.14 | 134.14 | 134.14 | 0.00 | 90.00 | 134.14 | 1.00 | 0.00 | RETAIL_1_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
23 | RETAIL_2_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 24.62 | 26.57 | 24.62 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | Door | RETAIL_2_FLR_1_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
25 | RETAIL_2_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
26 | RETAIL_2_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
27 | RETAIL_2_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 90.00 | 90.00 | 6.71 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | RETAIL_2_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 77.67 | 77.67 | 77.67 | 0.00 | 180.00 | 11.58 | 6.71 | 0.00 | BASEMENT_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
29 | RETAIL_2_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 155.34 | 155.34 | 155.34 | 0.00 | 90.00 | 155.34 | 1.00 | 0.00 | RETAIL_2_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
31 | MECH_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | MECH_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | MECH_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 180.00 | 90.00 | 15.85 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | MECH_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | MECH_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 164.24 | 164.24 | 164.24 | 0.00 | 180.00 | 15.85 | 10.36 | 0.00 | BASEMENT_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | MECH_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | MECH_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 328.49 | 328.49 | 328.49 | 0.00 | 90.00 | 328.49 | 1.00 | 0.00 | MECH_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | STORAGE_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 28.80 | 36.23 | 28.80 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | Door | STORAGE_FLR_1_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.198 | 1.198 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
40 | STORAGE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | STORAGE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 180.00 | 90.00 | 9.14 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
42 | STORAGE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | STORAGE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 94.76 | 94.76 | 94.76 | 0.00 | 180.00 | 9.14 | 10.36 | 0.00 | BASEMENT_CEILING_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
44 | STORAGE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | STORAGE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 189.52 | 189.52 | 189.52 | 0.00 | 90.00 | 189.52 | 1.00 | 0.00 | STORAGE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
46 | LAUNDRY_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | LAUNDRY_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 65.68 | 67.63 | 65.68 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | Door | LAUNDRY_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
49 | LAUNDRY_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 180.00 | 90.00 | 4.57 | 3.96 | 0.00 | CAFE_FLR_1_WALL_2_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | LAUNDRY_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 270.00 | 90.00 | 17.07 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | LAUNDRY_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 78.04 | 78.04 | 78.04 | 0.00 | 180.00 | 4.57 | 17.07 | 0.00 | BASEMENT_CEILING_5 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
52 | LAUNDRY_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 156.08 | 156.08 | 156.08 | 0.00 | 90.00 | 156.08 | 1.00 | 0.00 | LAUNDRY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
54 | CAFE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 21.00 | 22.95 | 21.00 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CAFE_FLR_1_WALL_EAST_DOOR | Door | CAFE_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | CAFE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 63.73 | 129.23 | 63.73 | 180.00 | 90.00 | 32.61 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | Window | CAFE_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 65.50 | 65.50 | 65.50 | 180.00 | 90.00 | 30.75 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
58 | CAFE_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 0.00 | 90.00 | 28.04 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | CAFE_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | CAFE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | CAFE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 188.86 | 188.86 | 188.86 | 0.00 | 180.00 | 32.61 | 5.79 | 0.00 | BASEMENT_CEILING_6 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
62 | CAFE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 3.86E-002 | 0.96 | 4 | ||
63 | CAFE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 377.72 | 377.72 | 377.72 | 0.00 | 90.00 | 377.72 | 1.00 | 0.00 | CAFE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
64 | LOBBY_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 209.87 | 213.77 | 209.87 | 0.00 | 90.00 | 53.95 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
67 | LOBBY_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 12.08 | 12.08 | 12.08 | 0.00 | 90.00 | 3.05 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | LOBBY_FLR_1_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 82.79 | 167.88 | 82.79 | 180.00 | 90.00 | 42.37 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | Window | LOBBY_FLR_1_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 85.08 | 85.08 | 85.08 | 180.00 | 90.00 | 39.95 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LOBBY_FLR_1_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.924 | 0.812 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | LOBBY_FLR_1_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | LOBBY_FLR_1_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 180.00 | 90.00 | 28.04 | 3.96 | 0.00 | CAFE_FLR_1_WALL_1_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | LOBBY_FLR_1_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
74 | LOBBY_FLR_1_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
75 | LOBBY_FLR_1_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | LOBBY_FLR_1_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | MECH_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | LOBBY_FLR_1_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
78 | LOBBY_FLR_1_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | LOBBY_FLR_1_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | CAFE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | LOBBY_FLR_1_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | LOBBY_FLR_1_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 180.00 | 32.99 | 32.99 | 0.00 | BASEMENT_CEILING_7 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
82 | LOBBY_FLR_1_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 219.63 | 219.63 | 219.63 | 90.00 | 180.00 | 14.82 | 14.82 | 0.00 | BASEMENT_CEILING_8 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
83 | LOBBY_FLR_1_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1062.83 | 1062.83 | 1062.83 | 270.00 | 0.00 | 32.60 | 32.60 | 0.00 | LOBBY_FLR_1_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 10 | ||
84 | LOBBY_FLR_1_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 245.35 | 245.35 | 245.35 | 180.00 | 0.00 | 42.37 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.22E-003 | 1.00 | 4 | ||
85 | LOBBY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 2616.37 | 2616.37 | 2616.37 | 0.00 | 90.00 | 2616.37 | 1.00 | 0.00 | LOBBY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | ROOM_1_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | ROOM_1_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | Window | ROOM_1_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | ROOM_1_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | ROOM_1_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | ROOM_1_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
93 | ROOM_1_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
94 | ROOM_1_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
95 | ROOM_2_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
97 | ROOM_2_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | Window | ROOM_2_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | ROOM_2_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | ROOM_2_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | ROOM_2_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | ROOM_2_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | ROOM_2_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 7.47 | 11.15 | 7.47 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 3.68 | 3.68 | 3.68 | 180.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | ROOM_3_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.52 | 24.52 | 24.52 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
110 | ROOM_3_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.52 | 24.52 | 24.52 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.05 | 49.05 | 49.05 | 0.00 | 90.00 | 49.05 | 1.00 | 0.00 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 7.47 | 11.15 | 7.47 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_4_MULT19_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 3.68 | 3.68 | 3.68 | 0.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
117 | ROOM_4_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
118 | ROOM_4_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
120 | ROOM_5_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | Window | ROOM_5_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
122 | ROOM_5_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_5_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
124 | ROOM_5_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
125 | ROOM_5_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
126 | ROOM_5_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
127 | ROOM_5_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
128 | ROOM_5_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_5_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
129 | ROOM_6_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_6_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
131 | ROOM_6_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.107 | 0.950 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | Window | ROOM_6_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
133 | ROOM_6_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
134 | ROOM_6_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
135 | ROOM_6_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
136 | ROOM_6_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
137 | ROOM_6_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_6_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
138 | CORRIDOR_FLR_3_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.217 | 1.029 | 11.83 | 17.65 | 11.83 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 5.82 | 5.82 | 5.82 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.217 | 1.029 | 4.35 | 6.50 | 4.35 | 0.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 2.15 | 2.15 | 2.15 | 0.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.217 | 1.029 | 4.36 | 6.50 | 4.36 | 180.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 2.15 | 2.15 | 2.15 | 180.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.217 | 1.029 | 11.83 | 17.65 | 11.83 | 180.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 5.82 | 5.82 | 5.82 | 180.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 0.00 | 90.00 | 69.50 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | CORRIDOR_FLR_3_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | CORRIDOR_FLR_3_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | CORRIDOR_FLR_3_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
150 | CORRIDOR_FLR_3_WALL_4_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 180.00 | 90.00 | 69.49 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
152 | CORRIDOR_FLR_3_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | CORRIDOR_FLR_3_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
154 | CORRIDOR_FLR_3_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | CORRIDOR_FLR_3_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | CORRIDOR_FLR_3_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 180.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
157 | CORRIDOR_FLR_3_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 240.77 | 240.77 | 240.77 | 270.00 | 180.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | CORRIDOR_FLR_3_FLOOR_3 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 90.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
159 | CORRIDOR_FLR_3_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
160 | CORRIDOR_FLR_3_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 240.77 | 240.77 | 240.77 | 90.00 | 0.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
161 | CORRIDOR_FLR_3_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 778.81 | 778.81 | 778.81 | 0.00 | 90.00 | 778.81 | 1.00 | 0.00 | CORRIDOR_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
163 | ROOM_1_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.174 | 0.999 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
165 | ROOM_1_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.174 | 0.999 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | Window | ROOM_1_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
167 | ROOM_1_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
168 | ROOM_1_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
169 | ROOM_1_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
170 | ROOM_1_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
171 | ROOM_1_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
172 | ROOM_2_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.174 | 0.999 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
174 | ROOM_2_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.174 | 0.999 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | Window | ROOM_2_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
176 | ROOM_2_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
177 | ROOM_2_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
178 | ROOM_2_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
179 | ROOM_2_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
180 | ROOM_2_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.174 | 0.999 | 13.70 | 20.44 | 13.70 | 180.00 | 90.00 | 6.71 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 6.74 | 6.74 | 6.74 | 180.00 | 90.00 | 5.53 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 0.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 90.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
186 | ROOM_3_MULT9_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 6.71 | 3.66 | 0.00 | ROOM_3_MULT9_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
187 | ROOM_3_MULT9_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 6.71 | 3.66 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
189 | BANQUET_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 65.36 | 97.55 | 65.36 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | Window | BANQUET_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 32.19 | 32.19 | 32.19 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
191 | BANQUET_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
192 | BANQUET_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
193 | BANQUET_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
194 | BANQUET_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | BANQUET_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
195 | BANQUET_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
196 | BANQUET_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | BANQUET_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
197 | DINING_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 65.36 | 97.55 | 65.36 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
198 | DINING_FLR_6_WALL_NORTH_WINDOW | Window | DINING_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 32.19 | 32.19 | 32.19 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
199 | DINING_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
200 | DINING_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | DINING_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
201 | DINING_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
202 | DINING_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | DINING_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
203 | DINING_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
204 | DINING_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | DINING_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
205 | KITCHEN_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 16.77 | 21.37 | 16.77 | 0.00 | 90.00 | 7.01 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | Window | KITCHEN_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
207 | KITCHEN_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 34.86 | 52.03 | 34.86 | 90.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | Window | KITCHEN_FLR_6_WALL_EAST | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 17.17 | 17.17 | 17.17 | 90.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | Window | KITCHEN_FLR_6_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 7.43 | 7.43 | 7.43 | 180.00 | 90.00 | 2.44 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
212 | KITCHEN_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
213 | KITCHEN_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
214 | KITCHEN_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 103.30 | 103.30 | 103.30 | 180.00 | 180.00 | 10.16 | 10.16 | 0.00 | KITCHEN_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
215 | KITCHEN_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 103.30 | 103.30 | 103.30 | 270.00 | 0.00 | 10.16 | 10.16 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
216 | KITCHEN_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 206.61 | 206.61 | 206.61 | 0.00 | 90.00 | 206.61 | 1.00 | 0.00 | KITCHEN_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
217 | CORRIDOR_FLR_6_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 11.83 | 17.65 | 11.83 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 5.82 | 5.82 | 5.82 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 10.58 | 15.79 | 10.58 | 0.00 | 90.00 | 5.18 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 5.21 | 5.21 | 5.21 | 0.00 | 90.00 | 4.27 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.286 | 1.078 | 34.86 | 52.03 | 34.86 | 180.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3856_SHGC_0.4 | N/A | 2.191 | No | 17.17 | 17.17 | 17.17 | 180.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
224 | CORRIDOR_FLR_6_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 104.98 | 104.98 | 104.98 | 0.00 | 90.00 | 34.44 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 183.95 | 183.95 | 183.95 | 180.00 | 90.00 | 60.35 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
226 | CORRIDOR_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
227 | CORRIDOR_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 40.88 | 40.88 | 40.88 | 270.00 | 90.00 | 13.41 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
228 | CORRIDOR_FLR_6_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
229 | CORRIDOR_FLR_6_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
230 | CORRIDOR_FLR_6_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
231 | CORRIDOR_FLR_6_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
232 | CORRIDOR_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 412.12 | 412.12 | 412.12 | 180.00 | 180.00 | 20.30 | 20.30 | 0.00 | CORRIDOR_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 12 | ||
233 | CORRIDOR_FLR_6_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 244.71 | 244.71 | 244.71 | 90.00 | 0.00 | 15.64 | 15.64 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
234 | CORRIDOR_FLR_6_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 167.42 | 167.42 | 167.42 | 270.00 | 0.00 | 12.94 | 12.94 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 824.25 | 824.25 | 824.25 | 0.00 | 90.00 | 824.25 | 1.00 | 0.00 | CORRIDOR_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BASEMENT | RunPeriod: RUNPERIOD 1 | 1.8409640912E-002 | 2.2691035847E-002 | Pass | Pass | 3.1324036862E-003 | 7.3786200161E-003 | Pass | Pass |
2 | RETAIL_1_FLR_1 | RunPeriod: RUNPERIOD 1 | 8.4863837027E-003 | 2.4393785013E-002 | Pass | Pass | 0.2765834562 | 1.4373182880 | Pass | Pass |
3 | RETAIL_2_FLR_1 | RunPeriod: RUNPERIOD 1 | 5.9363975531E-003 | 1.4862572296E-002 | Pass | Pass | 3.0109355795E-002 | 6.4334203665E-002 | Pass | Pass |
4 | MECH_FLR_1 | RunPeriod: RUNPERIOD 1 | 5.8304774838E-004 | 4.4176458791E-004 | Pass | Pass | 9.2348667478E-002 | 0.2094307715 | Pass | Pass |
5 | STORAGE_FLR_1 | RunPeriod: RUNPERIOD 1 | 5.2057468753E-004 | 4.1041634330E-004 | Pass | Pass | 2.3207899507E-002 | 3.3198148942E-002 | Pass | Pass |
6 | LAUNDRY_FLR_1 | RunPeriod: RUNPERIOD 1 | 7.8140841725E-002 | 0.2280562792 | Pass | Pass | 1.9421927407E-002 | 5.1722191879E-002 | Pass | Pass |
7 | CAFE_FLR_1 | RunPeriod: RUNPERIOD 1 | 3.6906940804E-002 | 8.0008112813E-002 | Pass | Pass | 5.2316182814E-002 | 0.1008342073 | Pass | Pass |
8 | LOBBY_FLR_1 | RunPeriod: RUNPERIOD 1 | 2.9814174962E-002 | 4.1950745281E-002 | Pass | Pass | 1.8886665374E-002 | 4.0015751356E-002 | Pass | Pass |
9 | ROOM_1_FLR_3 | RunPeriod: RUNPERIOD 1 | 9.5831681791E-002 | 0.3290211173 | Pass | Pass | 0.3492258996 | 1.4218093591 | Pass | Pass |
10 | ROOM_2_FLR_3 | RunPeriod: RUNPERIOD 1 | 9.2661594706E-002 | 0.3426967519 | Pass | Pass | 0.1130947555 | 0.3297190520 | Pass | Pass |
11 | ROOM_3_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 2.8322939971E-002 | 4.9839203132E-002 | Pass | Pass | 0.2383904674 | 0.8951027667 | Pass | Pass |
12 | ROOM_4_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.9670783595E-002 | 0.2181016067 | Pass | Pass | 0.2555529857 | 1.6051438202 | Pass | Pass |
13 | ROOM_5_FLR_3 | RunPeriod: RUNPERIOD 1 | 7.9828711517E-002 | 0.2792653374 | Pass | Pass | 4.2134981320 | 47.4848546204 | Pass | Pass |
14 | ROOM_6_FLR_3 | RunPeriod: RUNPERIOD 1 | 8.6858960480E-002 | 0.3126008231 | Pass | Pass | 0.2585267455 | 1.1515236594 | Pass | Pass |
15 | CORRIDOR_FLR_3 | RunPeriod: RUNPERIOD 1 | 4.2564719632E-004 | 3.3352551622E-004 | Pass | Pass | 0.4301483826 | 1.8750295763 | Pass | Pass |
16 | ROOM_1_FLR_6 | RunPeriod: RUNPERIOD 1 | 9.2660941401E-002 | 0.3495662724 | Pass | Pass | 0.1767333555 | 0.7925694993 | Pass | Pass |
17 | ROOM_2_FLR_6 | RunPeriod: RUNPERIOD 1 | 9.2665602114E-002 | 0.3598680058 | Pass | Pass | 0.1192853048 | 0.4470646557 | Pass | Pass |
18 | ROOM_3_MULT9_FLR_6 | RunPeriod: RUNPERIOD 1 | 8.1632337414E-002 | 0.2406659481 | Pass | Pass | 0.2226694490 | 0.8572105047 | Pass | Pass |
19 | BANQUET_FLR_6 | RunPeriod: RUNPERIOD 1 | 5.4039627495E-002 | 9.7142904995E-002 | Pass | Pass | 8.2502347555E-003 | 1.9334748276E-002 | Pass | Pass |
20 | DINING_FLR_6 | RunPeriod: RUNPERIOD 1 | 4.8576603835E-002 | 8.6135766502E-002 | Pass | Pass | 8.3091290631E-003 | 1.9848598625E-002 | Pass | Pass |
21 | KITCHEN_FLR_6 | RunPeriod: RUNPERIOD 1 | 3.6908375663E-002 | 0.1184031384 | Pass | Pass | 2.2386848780E-002 | 4.0263245156E-002 | Pass | Pass |
22 | CORRIDOR_FLR_6 | RunPeriod: RUNPERIOD 1 | 8.4501530631E-004 | 6.2267910039E-004 | Pass | Pass | 0.2268129804 | 1.0082150535 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 4411.28 | 100.10 | 1292.28 | 5392.19 | 5625.83 | 16821.67 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | -10.70 | 0.00 | -10.70 | Wetbulb [C] | 7.50 | 320.00 |
NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 32.10 | 7.40 | 23.10 | Wetbulb [C] | 5.60 | 230.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 172.00 | 59 | |||
Feb | 49.00 | 37 | |||
Mar | 40.00 | 38 | |||
Apr | 70.00 | 48 | |||
May | 70.00 | 36 | |||
Jun | 25.00 | 15 | |||
Jul | 64.00 | 20 | |||
Aug | 2.00 | 4 | |||
Sep | 73.00 | 32 | |||
Oct | 7.00 | 8 | |||
Nov | 88.00 | 34 | |||
Dec | 62.00 | 39 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_WALL_NORTH | BASEMENT_WALL_NORTH_CFACTOR | 1.00 | 0.399 | 0.419 | 211.13 | 211.13 | 0.00 | 90.00 | N |
BASEMENT_WALL_EAST | BASEMENT_WALL_EAST_CFACTOR | 1.00 | 0.399 | 0.419 | 55.76 | 55.76 | 90.00 | 90.00 | E |
BASEMENT_WALL_SOUTH | BASEMENT_WALL_SOUTH_CFACTOR | 1.00 | 0.399 | 0.419 | 211.13 | 211.13 | 180.00 | 90.00 | S |
BASEMENT_WALL_WEST | BASEMENT_WALL_WEST_CFACTOR | 1.00 | 0.399 | 0.419 | 55.76 | 55.76 | 270.00 | 90.00 | W |
RETAIL_1_FLR_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 45.89 | 22.63 | 180.00 | 90.00 | S |
RETAIL_1_FLR_1_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 22.95 | 22.95 | 270.00 | 90.00 | W |
RETAIL_1_FLR_1_CEILING | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 67.07 | 67.07 | 180.00 | 0.00 | |
RETAIL_2_FLR_1_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 26.57 | 24.62 | 270.00 | 90.00 | W |
MECH_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 62.80 | 62.80 | 0.00 | 90.00 | N |
STORAGE_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 36.23 | 28.80 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 18.12 | 18.12 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 67.63 | 65.68 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 22.95 | 21.00 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 129.23 | 63.73 | 180.00 | 90.00 | S |
CAFE_FLR_1_CEILING | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 188.86 | 188.86 | 180.00 | 0.00 | |
LOBBY_FLR_1_WALL_1_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 213.77 | 209.87 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_2_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 12.08 | 12.08 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_1_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 167.88 | 82.79 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_1_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.812 | 0.924 | 41.06 | 41.06 | 270.00 | 90.00 | W |
LOBBY_FLR_1_CEILING_2 | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 245.35 | 245.35 | 180.00 | 0.00 | |
ROOM_1_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_1_FLR_3_WALL_WEST | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 104.06 | 69.72 | 270.00 | 90.00 | W |
ROOM_2_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_2_FLR_3_WALL_WEST | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 104.05 | 69.71 | 270.00 | 90.00 | W |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 847.14 | 567.58 | 180.00 | 90.00 | S |
ROOM_4_MULT19_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 847.37 | 567.71 | 0.00 | 90.00 | N |
ROOM_5_FLR_3_WALL_EAST | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 104.06 | 69.72 | 90.00 | 90.00 | E |
ROOM_5_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_6_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_6_FLR_3_WALL_EAST | RES_EXT_WALL_MID | 0.30 | 0.950 | 1.107 | 104.05 | 69.71 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_1_NORTH | NONRES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 70.60 | 47.31 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_2_NORTH | NONRES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 26.01 | 17.42 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_1_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 26.02 | 17.43 | 180.00 | 90.00 | S |
CORRIDOR_FLR_3_WALL_2_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 70.60 | 47.31 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_SOUTH | RES_EXT_WALL_TOP | 0.30 | 0.999 | 1.174 | 13.94 | 9.34 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_WEST | RES_EXT_WALL_TOP | 0.30 | 0.999 | 1.174 | 26.01 | 17.43 | 270.00 | 90.00 | W |
ROOM_1_FLR_6_CEILING | RES_ROOF | 0.23 | 0.182 | 0.186 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_2_FLR_6_WALL_NORTH | RES_EXT_WALL_TOP | 0.30 | 0.999 | 1.174 | 13.94 | 9.34 | 0.00 | 90.00 | N |
ROOM_2_FLR_6_WALL_WEST | RES_EXT_WALL_TOP | 0.30 | 0.999 | 1.174 | 26.01 | 17.43 | 270.00 | 90.00 | W |
ROOM_2_FLR_6_CEILING | RES_ROOF | 0.23 | 0.182 | 0.186 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | RES_EXT_WALL_TOP | 0.30 | 0.999 | 1.174 | 183.96 | 123.26 | 180.00 | 90.00 | S |
ROOM_3_MULT9_FLR_6_CEILING | RES_ROOF | 0.23 | 0.182 | 0.186 | 220.77 | 220.77 | 180.00 | 0.00 | |
BANQUET_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 97.55 | 65.36 | 0.00 | 90.00 | N |
BANQUET_FLR_6_CEILING | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 331.66 | 331.66 | 180.00 | 0.00 | |
DINING_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 97.55 | 65.36 | 0.00 | 90.00 | N |
DINING_FLR_6_CEILING | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 331.66 | 331.66 | 180.00 | 0.00 | |
KITCHEN_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 21.37 | 16.77 | 0.00 | 90.00 | N |
KITCHEN_FLR_6_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 52.03 | 34.86 | 90.00 | 90.00 | E |
KITCHEN_FLR_6_WALL_1_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 13.94 | 9.34 | 180.00 | 90.00 | S |
KITCHEN_FLR_6_CEILING | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 103.30 | 103.30 | 270.00 | 0.00 | |
CORRIDOR_FLR_6_WALL_1_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 17.65 | 11.83 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 15.79 | 10.58 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 52.03 | 34.86 | 180.00 | 90.00 | S |
CORRIDOR_FLR_6_CEILING_1 | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 244.71 | 244.71 | 90.00 | 0.00 | |
CORRIDOR_FLR_6_CEILING_2 | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 167.42 | 167.42 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_FLOOR | BASEMENT_FLOOR | 0.30 | 1.441 | 2.705 | 1978.83 | 1978.83 | 0.00 | 180.00 | |
BASEMENT_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 67.07 | 67.07 | 180.00 | 0.00 | |
BASEMENT_CEILING_2 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 77.67 | 77.67 | 180.00 | 0.00 | |
BASEMENT_CEILING_3 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 164.24 | 164.24 | 180.00 | 0.00 | |
BASEMENT_CEILING_4 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 94.76 | 94.76 | 180.00 | 0.00 | |
BASEMENT_CEILING_5 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 78.04 | 78.04 | 180.00 | 0.00 | |
BASEMENT_CEILING_6 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 188.86 | 188.86 | 180.00 | 0.00 | |
BASEMENT_CEILING_7 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 1088.56 | 1088.56 | 180.00 | 0.00 | |
BASEMENT_CEILING_8 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 219.63 | 219.63 | 90.00 | 0.00 | |
RETAIL_1_FLR_1_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 0.00 | 90.00 | N |
RETAIL_1_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 90.00 | 90.00 | E |
RETAIL_1_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 67.07 | 67.07 | 0.00 | 180.00 | |
RETAIL_2_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 180.00 | 90.00 | S |
RETAIL_2_FLR_1_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 0.00 | 90.00 | N |
RETAIL_2_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.57 | 26.57 | 90.00 | 90.00 | E |
RETAIL_2_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 77.67 | 77.67 | 0.00 | 180.00 | |
RETAIL_2_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 77.67 | 77.67 | 180.00 | 0.00 | |
MECH_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
MECH_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 62.80 | 62.80 | 180.00 | 90.00 | S |
MECH_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
MECH_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 164.24 | 164.24 | 0.00 | 180.00 | |
MECH_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 164.24 | 164.24 | 180.00 | 0.00 | |
STORAGE_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
STORAGE_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 36.23 | 36.23 | 180.00 | 90.00 | S |
STORAGE_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
STORAGE_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 94.76 | 94.76 | 0.00 | 180.00 | |
STORAGE_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 94.76 | 94.76 | 180.00 | 0.00 | |
LAUNDRY_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 18.12 | 18.12 | 180.00 | 90.00 | S |
LAUNDRY_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 67.63 | 67.63 | 270.00 | 90.00 | W |
LAUNDRY_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 78.04 | 78.04 | 0.00 | 180.00 | |
LAUNDRY_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 78.04 | 78.04 | 180.00 | 0.00 | |
CAFE_FLR_1_WALL_1_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.11 | 111.11 | 0.00 | 90.00 | N |
CAFE_FLR_1_WALL_2_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 18.12 | 18.12 | 0.00 | 90.00 | N |
CAFE_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 270.00 | 90.00 | W |
CAFE_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 188.86 | 188.86 | 0.00 | 180.00 | |
LOBBY_FLR_1_WALL_2_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_3_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.11 | 111.11 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.57 | 26.57 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_4_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 62.80 | 62.80 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_4_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 36.23 | 36.23 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
LOBBY_FLR_1_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 90.00 | 90.00 | E |
LOBBY_FLR_1_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 67.63 | 67.63 | 90.00 | 90.00 | E |
LOBBY_FLR_1_FLOOR_1 | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 1088.56 | 1088.56 | 180.00 | 180.00 | |
LOBBY_FLR_1_FLOOR_2 | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 219.63 | 219.63 | 90.00 | 180.00 | |
LOBBY_FLR_1_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1062.83 | 1062.83 | 270.00 | 0.00 | |
ROOM_1_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 0.00 | 90.00 | N |
ROOM_1_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 90.00 | 90.00 | E |
ROOM_1_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.09 | 156.09 | 0.00 | 180.00 | |
ROOM_1_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.09 | 156.09 | 180.00 | 0.00 | |
ROOM_2_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 90.00 | 90.00 | E |
ROOM_2_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 180.00 | 90.00 | S |
ROOM_2_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.07 | 156.07 | 0.00 | 180.00 | |
ROOM_2_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.07 | 156.07 | 180.00 | 0.00 | |
ROOM_3_MULT19_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.14 | 847.14 | 0.00 | 90.00 | N |
ROOM_3_MULT19_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 90.00 | 90.00 | E |
ROOM_3_MULT19_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 270.00 | 90.00 | W |
ROOM_3_MULT19_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 1863.81 | 1863.81 | 0.00 | 180.00 | |
ROOM_3_MULT19_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1863.81 | 1863.81 | 180.00 | 0.00 | |
ROOM_4_MULT19_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 90.00 | 90.00 | E |
ROOM_4_MULT19_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.37 | 847.37 | 180.00 | 90.00 | S |
ROOM_4_MULT19_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 270.00 | 90.00 | W |
ROOM_4_MULT19_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 1864.32 | 1864.32 | 0.00 | 180.00 | |
ROOM_4_MULT19_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1864.32 | 1864.32 | 180.00 | 0.00 | |
ROOM_5_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 0.00 | 90.00 | N |
ROOM_5_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 270.00 | 90.00 | W |
ROOM_5_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.09 | 156.09 | 0.00 | 180.00 | |
ROOM_5_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.09 | 156.09 | 180.00 | 0.00 | |
ROOM_6_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 180.00 | 90.00 | S |
ROOM_6_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 270.00 | 90.00 | W |
ROOM_6_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.07 | 156.07 | 0.00 | 180.00 | |
ROOM_6_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.07 | 156.07 | 180.00 | 0.00 | |
CORRIDOR_FLR_3_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.28 | 847.28 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_4_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_3_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.27 | 847.27 | 180.00 | 90.00 | S |
CORRIDOR_FLR_3_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_4_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_FLOOR_1 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 297.29 | 297.29 | 180.00 | 180.00 | |
CORRIDOR_FLR_3_FLOOR_2 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 963.06 | 963.06 | 270.00 | 180.00 | |
CORRIDOR_FLR_3_FLOOR_3 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 297.26 | 297.26 | 90.00 | 180.00 | |
CORRIDOR_FLR_3_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 297.29 | 297.29 | 90.00 | 0.00 | |
CORRIDOR_FLR_3_CEILING_2 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 963.06 | 963.06 | 90.00 | 0.00 | |
CORRIDOR_FLR_3_CEILING_3 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 297.26 | 297.26 | 90.00 | 0.00 | |
ROOM_1_FLR_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 13.94 | 13.94 | 0.00 | 90.00 | N |
ROOM_1_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.01 | 26.01 | 90.00 | 90.00 | E |
ROOM_1_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 39.02 | 39.02 | 0.00 | 180.00 | |
ROOM_2_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.01 | 26.01 | 90.00 | 90.00 | E |
ROOM_2_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 13.94 | 13.94 | 180.00 | 90.00 | S |
ROOM_2_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 39.02 | 39.02 | 0.00 | 180.00 | |
ROOM_3_MULT9_FLR_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 183.96 | 183.96 | 0.00 | 90.00 | N |
ROOM_3_MULT9_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 100.35 | 100.35 | 90.00 | 90.00 | E |
ROOM_3_MULT9_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 100.35 | 100.35 | 270.00 | 90.00 | W |
ROOM_3_MULT9_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 220.77 | 220.77 | 0.00 | 180.00 | |
BANQUET_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
BANQUET_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 180.00 | 90.00 | S |
BANQUET_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
BANQUET_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 331.66 | 331.66 | 0.00 | 180.00 | |
DINING_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
DINING_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 180.00 | 90.00 | S |
DINING_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
DINING_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 331.66 | 331.66 | 0.00 | 180.00 | |
KITCHEN_FLR_6_WALL_2_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 7.43 | 7.43 | 180.00 | 90.00 | S |
KITCHEN_FLR_6_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 20.44 | 20.44 | 270.00 | 90.00 | W |
KITCHEN_FLR_6_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
KITCHEN_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 103.30 | 103.30 | 180.00 | 180.00 | |
CORRIDOR_FLR_6_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_4_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 104.98 | 104.98 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_1_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 183.95 | 183.95 | 180.00 | 90.00 | S |
CORRIDOR_FLR_6_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 11.15 | 11.15 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 40.88 | 40.88 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 20.44 | 20.44 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 412.12 | 412.12 | 180.00 | 180.00 | |
BASEMENT_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3957.66 | 0.00 | 90.00 | N | ||
RETAIL_1_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 134.14 | 0.00 | 90.00 | N | ||
RETAIL_2_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 155.34 | 0.00 | 90.00 | N | ||
MECH_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 328.49 | 0.00 | 90.00 | N | ||
STORAGE_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 189.52 | 0.00 | 90.00 | N | ||
LAUNDRY_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 156.08 | 0.00 | 90.00 | N | ||
CAFE_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 377.72 | 0.00 | 90.00 | N | ||
LOBBY_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 2616.37 | 0.00 | 90.00 | N | ||
ROOM_1_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.18 | 0.00 | 90.00 | N | ||
ROOM_2_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.14 | 0.00 | 90.00 | N | ||
ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3727.63 | 0.00 | 90.00 | N | ||
ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3728.64 | 0.00 | 90.00 | N | ||
ROOM_5_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.18 | 0.00 | 90.00 | N | ||
ROOM_6_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.14 | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3115.24 | 0.00 | 90.00 | N | ||
ROOM_1_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 78.04 | 0.00 | 90.00 | N | ||
ROOM_2_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 78.03 | 0.00 | 90.00 | N | ||
ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 441.55 | 0.00 | 90.00 | N | ||
BANQUET_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 663.31 | 0.00 | 90.00 | N | ||
DINING_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 663.31 | 0.00 | 90.00 | N | ||
KITCHEN_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 206.61 | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 824.25 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 23.26 | 0.00 | 0.00 | 23.26 | 23.26 | 2.191 | 0.401 | 0.402 | No | RETAIL_1_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
CAFE_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 65.50 | 0.00 | 0.00 | 65.50 | 65.50 | 2.191 | 0.401 | 0.402 | No | CAFE_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
LOBBY_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 85.08 | 0.00 | 0.00 | 85.08 | 85.08 | 2.191 | 0.401 | 0.402 | No | LOBBY_FLR_1_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.191 | 0.401 | 0.402 | No | ROOM_1_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.191 | 0.401 | 0.402 | No | ROOM_1_FLR_3_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_2_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.191 | 0.401 | 0.402 | No | ROOM_2_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_2_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.191 | 0.401 | 0.402 | No | ROOM_2_FLR_3_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 3.68 | 0.00 | 0.00 | 3.68 | 279.56 | 2.191 | 0.401 | 0.402 | No | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 3.68 | 0.00 | 0.00 | 3.68 | 279.65 | 2.191 | 0.401 | 0.402 | No | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_5_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.191 | 0.401 | 0.402 | No | ROOM_5_FLR_3_WALL_EAST | 90.00 | 90.00 | E | |||||||
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.191 | 0.401 | 0.402 | No | ROOM_5_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_6_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.191 | 0.401 | 0.402 | No | ROOM_6_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_6_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.191 | 0.401 | 0.402 | No | ROOM_6_FLR_3_WALL_EAST | 90.00 | 90.00 | E | |||||||
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 5.82 | 0.00 | 0.00 | 5.82 | 23.30 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_3_WALL_1_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 2.15 | 0.00 | 0.00 | 2.15 | 8.59 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_3_WALL_2_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 2.15 | 0.00 | 0.00 | 2.15 | 8.58 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_3_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 5.82 | 0.00 | 0.00 | 5.82 | 23.30 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_3_WALL_2_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.191 | 0.401 | 0.402 | No | ROOM_1_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 8.58 | 2.191 | 0.401 | 0.402 | No | ROOM_1_FLR_6_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_2_FLR_6_WALL_NORTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.191 | 0.401 | 0.402 | No | ROOM_2_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_2_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 8.58 | 0.00 | 0.00 | 8.58 | 8.58 | 2.191 | 0.401 | 0.402 | No | ROOM_2_FLR_6_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.3856_SHGC_0.4 | 6.74 | 0.00 | 0.00 | 6.74 | 60.70 | 2.191 | 0.401 | 0.402 | No | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
BANQUET_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 32.19 | 0.00 | 0.00 | 32.19 | 32.19 | 2.191 | 0.401 | 0.402 | No | BANQUET_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
DINING_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 32.19 | 0.00 | 0.00 | 32.19 | 32.19 | 2.191 | 0.401 | 0.402 | No | DINING_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
KITCHEN_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.191 | 0.401 | 0.402 | No | KITCHEN_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
KITCHEN_FLR_6_WALL_EAST_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 17.17 | 0.00 | 0.00 | 17.17 | 17.17 | 2.191 | 0.401 | 0.402 | No | KITCHEN_FLR_6_WALL_EAST | 90.00 | 90.00 | E | |||||||
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.191 | 0.401 | 0.402 | No | KITCHEN_FLR_6_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 5.82 | 0.00 | 0.00 | 5.82 | 5.82 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_6_WALL_1_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 5.21 | 0.00 | 0.00 | 5.21 | 5.21 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_6_WALL_2_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.3856_SHGC_0.4 | 17.17 | 0.00 | 0.00 | 17.17 | 17.17 | 2.191 | 0.401 | 0.402 | No | CORRIDOR_FLR_6_WALL_2_SOUTH | 180.00 | 90.00 | S | |||||||
Total or Average | 1213.79 | 2.191 | 0.401 | 0.402 | |||||||||||||||||
North Total or Average | 432.95 | 2.191 | 0.401 | 0.402 | |||||||||||||||||
Non-North Total or Average | 780.84 | 2.191 | 0.401 | 0.402 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
RETAIL_2_FLR_1_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | RETAIL_2_FLR_1_WALL_WEST |
STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | STORAGE_FLR_1_WALL_NORTH |
LAUNDRY_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LAUNDRY_FLR_1_WALL_EAST |
CAFE_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CAFE_FLR_1_WALL_EAST |
LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CAFE_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LOBBY_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
BANQUET_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BASEMENT_LIGHTS | BASEMENT | BASEMENT | GENERAL | 9.1389 | 1978.83 | 18084.33 | LightsWired | LTG_SCH_BASEMENT | 51.16 | 168.00 | 51.10 | 0.0000 | Y | 173.46 |
RETAIL_1_FLR_1_LIGHTS | RETAIL_1_FLR_1 | RETAIL_1_FLR_1 | GENERAL | 13.3365 | 67.07 | 894.50 | LightsWired | LTG_SCH_RETAIL | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 8.61 |
RETAIL_2_FLR_1_LIGHTS | RETAIL_2_FLR_1 | RETAIL_2_FLR_1 | GENERAL | 13.3365 | 77.67 | 1035.83 | LightsWired | LTG_SCH_RETAIL | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 9.97 |
MECH_FLR_1_LIGHTS | MECH_FLR_1 | MECH_FLR_1 | GENERAL | 9.2031 | 164.24 | 1511.55 | LightsWired | LTG_SCH_MECHANIC | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 16.63 |
STORAGE_FLR_1_LIGHTS | STORAGE_FLR_1 | STORAGE_FLR_1 | GENERAL | 6.1031 | 94.76 | 578.33 | LightsWired | LTG_SCH_STORAGE | 25.68 | 168.00 | 25.65 | 0.0000 | Y | 2.78 |
LAUNDRY_FLR_1_LIGHTS | LAUNDRY_FLR_1 | LAUNDRY_FLR_1 | GENERAL | 5.8125 | 78.04 | 453.60 | LightsWired | LTG_SCH_LAUNDRY | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 4.37 |
CAFE_FLR_1_LIGHTS | CAFE_FLR_1 | CAFE_FLR_1 | GENERAL | 10.3656 | 188.86 | 1957.67 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 48.78 | 0.0000 | Y | 17.93 |
LOBBY_FLR_1_LIGHTS | LOBBY_FLR_1 | LOBBY_FLR_1 | GENERAL | 8.7188 | 1308.19 | 11405.76 | LightsWired | LTG_SCH_LOBBY | 58.69 | 168.00 | 56.92 | 0.0000 | Y | 121.86 |
ROOM_1_FLR_3_LIGHTS | ROOM_1_FLR_3 | ROOM_1_FLR_3 | GENERAL | 4.5531 | 156.09 | 710.69 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 6.37 |
ROOM_2_FLR_3_LIGHTS | ROOM_2_FLR_3 | ROOM_2_FLR_3 | GENERAL | 4.5531 | 156.07 | 710.61 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 6.37 |
ROOM_3_MULT19_FLR_3_LIGHTS | ROOM_3_MULT19_FLR_3 | ROOM_3_MULT19_FLR_3 | GENERAL | 4.5531 | 1863.81 | 8486.17 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 76.02 |
ROOM_4_MULT19_FLR_3_LIGHTS | ROOM_4_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | GENERAL | 4.5531 | 1864.32 | 8488.49 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 76.04 |
ROOM_5_FLR_3_LIGHTS | ROOM_5_FLR_3 | ROOM_5_FLR_3 | GENERAL | 4.5531 | 156.09 | 710.69 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 6.37 |
ROOM_6_FLR_3_LIGHTS | ROOM_6_FLR_3 | ROOM_6_FLR_3 | GENERAL | 4.5531 | 156.07 | 710.61 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 6.37 |
CORRIDOR_FLR_3_LIGHTS | CORRIDOR_FLR_3 | CORRIDOR_FLR_3 | GENERAL | 6.3938 | 1557.62 | 9959.03 | LightsWired | LTG_SCH_CORRIDOR | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 109.60 |
ROOM_1_FLR_6_LIGHTS | ROOM_1_FLR_6 | ROOM_1_FLR_6 | GENERAL | 4.5531 | 39.02 | 177.67 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 1.59 |
ROOM_2_FLR_6_LIGHTS | ROOM_2_FLR_6 | ROOM_2_FLR_6 | GENERAL | 4.5531 | 39.02 | 177.65 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 1.59 |
ROOM_3_MULT9_FLR_6_LIGHTS | ROOM_3_MULT9_FLR_6 | ROOM_3_MULT9_FLR_6 | GENERAL | 4.5531 | 220.77 | 1005.22 | LightsWired | LTG_SCH_GUESTROOM | 47.59 | 168.00 | 47.72 | 0.0000 | Y | 9.00 |
BANQUET_FLR_6_LIGHTS | BANQUET_FLR_6 | BANQUET_FLR_6 | GENERAL | 10.3656 | 331.66 | 3437.84 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 53.67 | 0.0000 | Y | 34.63 |
DINING_FLR_6_LIGHTS | DINING_FLR_6 | DINING_FLR_6 | GENERAL | 10.3656 | 331.66 | 3437.84 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 53.67 | 0.0000 | Y | 34.63 |
KITCHEN_FLR_6_LIGHTS | KITCHEN_FLR_6 | KITCHEN_FLR_6 | GENERAL | 11.7219 | 103.30 | 1210.92 | LightsWired | LTG_SCH_KITCHEN | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 13.33 |
CORRIDOR_FLR_6_LIGHTS | CORRIDOR_FLR_6 | CORRIDOR_FLR_6 | GENERAL | 6.3938 | 412.12 | 2635.02 | LightsWired | LTG_SCH_CORRIDOR | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 29.00 |
Interior Lighting Total | 6.8557 | 11345.29 | 77780.02 | 507.17 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
LOBBY_FLR_1_DAYLREFPT1 | LOBBY_FLR_1 | LOBBY_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.07 | 11405.76 | 798.40 |
LOBBY_FLR_1_DAYLREFPT2 | LOBBY_FLR_1 | LOBBY_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.00 | 11405.76 | 0.00 |
CAFE_FLR_1_DAYLREFPT1 | CAFE_FLR_1 | CAFE_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.39 | 1957.67 | 763.49 |
CAFE_FLR_1_DAYLREFPT2 | CAFE_FLR_1 | CAFE_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.00 | 1957.67 | 0.00 |
DINING_FLR_6_DAYLREFPT1 | DINING_FLR_6 | DINING_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.20 | 3437.84 | 687.57 |
DINING_FLR_6_DAYLREFPT2 | DINING_FLR_6 | DINING_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.00 | 3437.84 | 0.00 |
BANQUET_FLR_6_DAYLREFPT1 | BANQUET_FLR_6 | BANQUET_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.20 | 3437.84 | 687.57 |
BANQUET_FLR_6_DAYLREFPT2 | BANQUET_FLR_6 | BANQUET_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.00 | 3437.84 | 0.00 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR FACADE LIGHTING | 15448.40 | AstronomicalClock | - | 83.64 | 83.64 | 242.55 | |
Exterior Lighting Total | 15448.40 | 242.55 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
HEATSYS1 BOILER | Boiler:HotWater | 490549.46 | 0.80 | ||||
COOLSYS1 CHILLER1 | Chiller:Electric:EIR | 1006860.85 | 2.96 | 1007037.83 | 2.96 | 3.93 | 13.40 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 13017.00 | 19136.07 | 15414.87 | 3721.20 | 0.81 | - | 2144.51 | 21.75 |
ROOM_2_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 12636.23 | 18567.10 | 14951.35 | 3615.75 | 0.81 | - | 2080.53 | 21.10 |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 73181.76 | 108303.29 | 87656.57 | 20646.72 | 0.81 | - | 12155.23 | 123.29 |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 68994.93 | 99728.81 | 79418.93 | 20309.88 | 0.80 | - | 11140.13 | 112.99 |
ROOM_5_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 11913.04 | 17485.21 | 14069.33 | 3415.88 | 0.80 | - | 1958.84 | 19.87 |
ROOM_6_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 11581.78 | 16990.04 | 13665.88 | 3324.16 | 0.80 | - | 1903.16 | 19.30 |
ROOM_1_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 3411.64 | 5019.06 | 4045.12 | 973.93 | 0.81 | - | 562.56 | 5.71 |
ROOM_2_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 3305.01 | 4859.75 | 3915.35 | 944.40 | 0.81 | - | 544.64 | 5.52 |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 15845.97 | 23182.44 | 18611.74 | 4570.70 | 0.80 | - | 2595.36 | 26.32 |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | 706034.18 | 639749.20 | 426343.79 | 213405.41 | 0.67 | - | 75479.46 | 765.55 |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | 86334.71 | 63544.84 | 41523.88 | 22020.96 | 0.65 | - | 7288.25 | 73.92 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
BASEMENT VAV BOX REHEAT COIL | Coil:Heating:Water | 7014.41 | 7050.63 | - |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 4102.09 | 4119.67 | - |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 1721.57 | 1729.63 | - |
MECH_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 2604.15 | 2615.15 | - |
STORAGE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 1495.16 | 1501.07 | - |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 11674.17 | 11733.62 | - |
CAFE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 11909.29 | 11964.56 | - |
LOBBY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 31385.41 | 31534.20 | - |
ROOM_1_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 6925.28 | 7459.11 | - |
ROOM_2_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 6944.49 | 7479.80 | - |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 39426.23 | 42464.95 | - |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 39798.13 | 42865.45 | - |
ROOM_5_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 6886.18 | 7417.00 | - |
ROOM_6_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 6905.40 | 7437.70 | - |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 15090.80 | 15156.30 | - |
ROOM_1_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 2085.98 | 2246.71 | - |
ROOM_2_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 2092.41 | 2253.64 | - |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 9911.65 | 10675.35 | - |
BANQUET_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 12730.98 | 12792.28 | - |
DINING_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 13167.56 | 13231.07 | - |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 8850.44 | 8895.25 | - |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 9028.71 | 9066.39 | - |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | 218405.54 | 154769.05 | - |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | 20393.42 | 14451.42 | - |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
LAUNDRY_FLR_1 EXHAUST FAN | Fan:ZoneExhaust | 0.39 | 125.00 | 0.24 | 76.61 | 324.68 | 1.00 | 2.78 | General | ||
LOBBY_FLR_1 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | General | |||
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 1.14 | 801.85 | 703.64 | 1.00 | 1.17 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 |
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 1.10 | 777.29 | 703.64 | 1.00 | 1.17 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 |
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 6.53 | 4595.19 | 703.64 | 1.00 | 0.95 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 |
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 5.76 | 4053.44 | 703.64 | 1.00 | 0.96 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 |
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 1.04 | 730.51 | 703.64 | 1.00 | 1.19 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:40:00 |
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 1.01 | 709.14 | 703.64 | 1.00 | 1.19 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 |
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 0.30 | 210.60 | 703.64 | 1.00 | 1.71 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 |
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 0.29 | 203.72 | 703.64 | 1.00 | 1.74 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 |
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.39 | 270.90 | 1.37 | 962.80 | 703.64 | 1.00 | 1.13 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 |
BANQUET_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.87 | 0.00 | 0.00 | 1.00 | 0.00 | General | ||
DINING_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.87 | 0.00 | 0.00 | 1.00 | 0.00 | General | ||
KITCHEN_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 0.39 | 125.00 | 1.89 | 612.92 | 324.68 | 1.00 | 1.48 | General | ||
VAV WITH REHEAT FAN | Fan:VariableVolume | 0.62 | 1389.42 | 21.97 | 49224.16 | 2240.64 | 1.00 | 1.11 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 |
FLR_3_DOAS FAN | Fan:ConstantVolume | 0.58 | 622.50 | 2.05 | 2194.93 | 1070.05 | 1.00 | 1.30 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
COOLSYS1 PUMP SECONDARY | Pump:VariableSpeed | Intermittent | 133527.72 | 0.035941 | 7406.11 | 206062.94 | 0.90 | General |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 180705.70 | 0.004292 | 1292.42 | 301156.09 | 0.90 | General |
COOLSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 92445.74 | 0.035941 | 5127.50 | 142664.32 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000375 | 47.91 | 127739.32 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWH BOOSTER E WATER HEATER | WaterHeater:Mixed | 0.02 | 8000.00 | 1.00 | 1.24 | 1.15 |
SWH LAUNDRY G WATER HEATER | WaterHeater:Mixed | 1.14 | 163316.00 | 0.80 | 0.58 | 0.51 |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.60 | 0.80 | 0.26 | 0.03 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 34629.44 | 34629.44 | 17.50 | 2.517 | 2.517 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 24.00 | 24.00 | 0.00920 | 28.94 | 0.01411 | 0.854 | 0.00 |
RETAIL_1_FLR_1 | 5343.95 | 5343.95 | 79.68 | 0.389 | 0.389 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:10:00 | 24.00 | 24.00 | 0.00908 | 31.79 | 0.01412 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 3305.70 | 3305.70 | 42.56 | 0.240 | 0.240 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:50:00 | 24.00 | 24.00 | 0.00943 | 31.73 | 0.01412 | 0.092 | 0.00 |
MECH_FLR_1 | 3212.85 | 3212.85 | 19.56 | 0.234 | 0.234 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:20:00 | 24.00 | 24.00 | 0.00888 | 31.46 | 0.01412 | 0.000 | 0.00 |
STORAGE_FLR_1 | 1557.05 | 1557.05 | 16.43 | 0.113 | 0.113 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 24.00 | 24.00 | 0.00902 | 32.03 | 0.01412 | 0.058 | 0.00 |
LAUNDRY_FLR_1 | 44902.36 | 44902.36 | 575.38 | 3.264 | 3.264 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 24.00 | 24.00 | 0.00856 | 32.10 | 0.01412 | 0.000 | 0.00 |
CAFE_FLR_1 | 21548.00 | 21548.00 | 114.09 | 1.568 | 1.568 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:10:00 | 24.00 | 23.99 | 0.01004 | 31.79 | 0.01412 | 0.676 | 0.00 |
LOBBY_FLR_1 | 65473.02 | 65473.02 | 50.05 | 4.761 | 4.761 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 24.00 | 23.99 | 0.01001 | 31.85 | 0.01412 | 1.894 | 0.00 |
ROOM_1_FLR_3 | 11633.22 | 11633.22 | 298.12 | 1.140 | 1.140 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 21.11 | 21.11 | 0.00867 | 31.36 | 0.01412 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 11276.97 | 11276.97 | 289.02 | 1.105 | 1.105 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 21.11 | 21.11 | 0.00867 | 31.26 | 0.01412 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 66672.55 | 66672.55 | 2718.68 | 6.531 | 6.531 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 21.11 | 21.11 | 0.00860 | 31.85 | 0.01412 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 58807.60 | 58807.60 | 2397.32 | 5.761 | 5.761 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 21.11 | 21.11 | 0.00885 | 32.10 | 0.01412 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 10598.29 | 10598.29 | 271.60 | 1.038 | 1.038 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:40:00 | 21.11 | 21.11 | 0.00868 | 28.87 | 0.01411 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 10288.16 | 10288.16 | 263.68 | 1.008 | 1.008 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 21.11 | 21.11 | 0.00869 | 28.45 | 0.01411 | 0.062 | 0.00 |
CORRIDOR_FLR_3 | 20691.81 | 20691.81 | 53.14 | 1.504 | 1.504 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 24.00 | 24.00 | 0.00950 | 32.10 | 0.01412 | 0.475 | 0.00 |
ROOM_1_FLR_6 | 3055.33 | 3055.33 | 78.30 | 0.299 | 0.299 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 21.11 | 21.11 | 0.00866 | 31.36 | 0.01412 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 2955.60 | 2955.60 | 75.75 | 0.290 | 0.290 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 21.11 | 21.11 | 0.00866 | 31.26 | 0.01412 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 13968.14 | 13968.14 | 569.42 | 1.368 | 1.368 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 21.11 | 21.11 | 0.00872 | 31.85 | 0.01412 | 0.099 | 0.00 |
BANQUET_FLR_6 | 29903.24 | 29903.24 | 90.16 | 2.176 | 2.176 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 24.00 | 23.98 | 0.01041 | 32.10 | 0.01412 | 1.188 | 0.00 |
DINING_FLR_6 | 31337.93 | 31337.93 | 94.49 | 2.281 | 2.281 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 24.00 | 23.99 | 0.01032 | 32.10 | 0.01412 | 1.188 | 0.00 |
KITCHEN_FLR_6 | 31140.21 | 31140.21 | 301.44 | 2.270 | 2.270 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:30:00 | 24.00 | 23.97 | 0.01008 | 31.43 | 0.01412 | 0.367 | 0.00 |
CORRIDOR_FLR_6 | 10656.07 | 10656.07 | 25.86 | 0.775 | 0.775 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 24.00 | 24.00 | 0.00905 | 31.98 | 0.01412 | 0.126 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.854 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 21.00 | 21.58 | 0.00150 | -10.70 | 0.00150 | 0.854 | 0.00 |
RETAIL_1_FLR_1 | 3020.75 | 3020.75 | 45.04 | 0.130 | 0.130 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00749 | -10.70 | 0.00150 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 1052.63 | 1052.63 | 13.55 | 0.045 | 0.092 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00745 | -10.70 | 0.00150 | 0.092 | 0.00 |
MECH_FLR_1 | 1954.31 | 1954.31 | 11.90 | 0.084 | 0.084 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00731 | -10.70 | 0.00150 | 0.000 | 0.00 |
STORAGE_FLR_1 | 1180.21 | 1180.21 | 12.45 | 0.051 | 0.058 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00734 | -10.70 | 0.00150 | 0.058 | 0.00 |
LAUNDRY_FLR_1 | 2592.62 | 2592.62 | 33.22 | 0.111 | 0.111 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00729 | -10.70 | 0.00150 | 0.000 | 0.00 |
CAFE_FLR_1 | 7544.97 | 7544.97 | 39.95 | 0.324 | 0.676 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00755 | -10.70 | 0.00150 | 0.676 | 0.00 |
LOBBY_FLR_1 | 18132.10 | 18132.10 | 13.86 | 0.778 | 1.894 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00747 | -10.70 | 0.00150 | 1.894 | 0.00 |
ROOM_1_FLR_3 | 6925.55 | 6925.55 | 177.48 | 0.299 | 0.299 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00749 | -10.70 | 0.00150 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 6944.76 | 6944.76 | 177.99 | 0.300 | 0.300 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00749 | -10.70 | 0.00150 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 39426.75 | 39426.75 | 1607.69 | 1.701 | 1.701 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.11 | 21.11 | 0.00752 | -10.70 | 0.00150 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 39798.66 | 39798.66 | 1622.41 | 1.717 | 1.717 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.11 | 21.11 | 0.00753 | -10.70 | 0.00150 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 6886.44 | 6886.44 | 176.48 | 0.297 | 0.297 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00749 | -10.70 | 0.00150 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 6905.67 | 6905.67 | 176.99 | 0.298 | 0.298 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00749 | -10.70 | 0.00150 | 0.062 | 0.00 |
CORRIDOR_FLR_3 | 10902.84 | 10902.84 | 28.00 | 0.468 | 0.475 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00760 | -10.70 | 0.00150 | 0.475 | 0.00 |
ROOM_1_FLR_6 | 2086.06 | 2086.06 | 53.46 | 0.090 | 0.090 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00757 | -10.70 | 0.00150 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 2092.49 | 2092.49 | 53.63 | 0.090 | 0.090 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00757 | -10.70 | 0.00150 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 9911.94 | 9911.94 | 404.07 | 0.428 | 0.428 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 21.11 | 21.11 | 0.00758 | -10.70 | 0.00150 | 0.099 | 0.00 |
BANQUET_FLR_6 | 6670.79 | 6670.79 | 20.11 | 0.286 | 1.188 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00767 | -10.70 | 0.00150 | 1.188 | 0.00 |
DINING_FLR_6 | 6816.64 | 6816.64 | 20.55 | 0.292 | 1.188 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00767 | -10.70 | 0.00150 | 1.188 | 0.00 |
KITCHEN_FLR_6 | 2545.68 | 2545.68 | 24.64 | 0.109 | 0.367 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | 21.00 | 21.00 | 0.00673 | -10.70 | 0.00150 | 0.367 | 0.00 |
CORRIDOR_FLR_6 | 6871.56 | 6871.56 | 16.67 | 0.295 | 0.295 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 21.00 | 21.00 | 0.00771 | -10.70 | 0.00150 | 0.126 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
VAV WITH REHEAT | 21.97 | 21.97 | 7.41 | 7.41 | 21.9688 | 11.6643 | 21.9688 | 0.5309 | 0.3000 |
FLR_3_DOAS | 17.43 | 2.05 | 5.22 | 2.05 | 2.0513 | 2.0513 | 2.0513 | 1.0000 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | 7014.406 | 7014.406 | 1.329122 | 0.00006137 | 146.273 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 7014.41 | 7014.41 | 1.329122 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00800000 | 51.6928 | 0.00 | 0.00 | 7053.83 | 7053.83 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | 4102.092 | 4102.092 | 0.205138 | 0.00003589 | 100.287 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 4102.09 | 4102.09 | 0.205138 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00749491 | 48.4711 | 3020.75 | 0.00 | 4123.39 | 4123.39 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | 1721.569 | 1721.569 | 0.126894 | 0.00001506 | 39.112 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 1721.57 | 1721.57 | 0.126894 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00744508 | 48.1507 | 1052.63 | 0.00 | 1730.84 | 1730.84 |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | 2604.154 | 2604.154 | 0.123304 | 0.00002278 | 64.535 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 2604.15 | 2604.15 | 0.123304 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00730966 | 47.2852 | 1954.31 | 0.00 | 2617.61 | 2617.61 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | 1495.163 | 1495.163 | 0.059757 | 0.00001308 | 38.907 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 1495.16 | 1495.16 | 0.059757 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00733734 | 47.4622 | 1180.21 | 0.00 | 1502.68 | 1502.68 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 11674.169 | 11674.169 | 1.723482 | 0.00010213 | 247.080 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 11674.17 | 11674.17 | 1.723482 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00729176 | 47.1727 | 2592.62 | 0.00 | 11739.44 | 11739.44 |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | 11909.289 | 11909.289 | 0.827817 | 0.00010419 | 273.007 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 11909.29 | 11909.29 | 0.827817 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00754895 | 48.8158 | 7544.97 | 0.00 | 11973.24 | 11973.24 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 31385.415 | 31385.415 | 2.513950 | 0.00027457 | 704.718 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 31385.41 | 31385.41 | 2.513950 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00747062 | 48.3139 | 18132.10 | 0.00 | 31555.21 | 31555.21 |
ROOM_1_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 13017.001 | -999.000 | 1.139574 | 0.00046493 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | unknown | 7/21 16:30:00 | 13017.00 | 12501.80 | 1.139574 | 21.68 | 15.70 | 0.00866703 | 12.80 | 12.09 | 0.00850000 | 31.36 | 0.01411830 | 22.93 | 0.0000 | 21.11 | 0.00866703 | 55.5666 | 11633.22 | 0.00 | 13038.53 | 12331.29 |
ROOM_1_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 6925.284 | 6925.284 | 0.298714 | 0.00006059 | 197.906 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 6925.28 | 6925.28 | 0.298714 | 21.11 | 14.42 | 0.00749178 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00749178 | 48.1206 | 6925.55 | 0.00 | 7465.62 | 7465.62 |
ROOM_2_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 12636.230 | -999.000 | 1.104677 | 0.00045133 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | unknown | 7/21 16:40:00 | 12636.23 | 12120.92 | 1.104677 | 21.68 | 15.70 | 0.00867231 | 12.80 | 12.09 | 0.00850000 | 31.26 | 0.01411813 | 22.90 | 0.0000 | 21.11 | 0.00867231 | 55.6000 | 11276.97 | 0.00 | 12657.09 | 11956.47 |
ROOM_2_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 6944.493 | 6944.493 | 0.299542 | 0.00006075 | 198.455 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 6944.49 | 6944.49 | 0.299542 | 21.11 | 14.42 | 0.00749311 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00749311 | 48.1291 | 6944.76 | 0.00 | 7486.33 | 7486.33 |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 73181.758 | -999.000 | 6.530630 | 0.00261383 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | unknown | 7/21 13:20:00 | 73181.76 | 71490.99 | 6.530630 | 21.68 | 15.63 | 0.00859586 | 12.80 | 12.09 | 0.00850000 | 31.85 | 0.01411920 | 23.06 | 0.0000 | 21.11 | 0.00859586 | 55.1143 | 66672.55 | 0.00 | 73305.31 | 70446.21 |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 39426.227 | 39426.227 | 1.700612 | 0.00034492 | 1126.675 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 39426.23 | 39426.23 | 1.700612 | 21.11 | 14.45 | 0.00752418 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00752418 | 48.3260 | 39426.75 | 0.00 | 42502.48 | 42502.48 |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 68994.926 | -999.000 | 5.760697 | 0.00246429 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | unknown | 7/21 15:00:00 | 68994.93 | 63535.34 | 5.760697 | 21.68 | 15.85 | 0.00884827 | 12.80 | 12.09 | 0.00850000 | 32.10 | 0.01411964 | 23.13 | 0.0000 | 21.11 | 0.00884827 | 56.7122 | 58807.60 | 0.00 | 69103.54 | 62817.72 |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 39798.129 | 39798.129 | 1.716653 | 0.00034817 | 1137.300 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 39798.13 | 39798.13 | 1.716653 | 21.11 | 14.45 | 0.00752818 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00752818 | 48.3514 | 39798.66 | 0.00 | 42903.40 | 42903.40 |
ROOM_5_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 11913.040 | -999.000 | 1.038197 | 0.00042550 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:40:00 | unknown | 7/21 09:40:00 | 11913.04 | 11395.54 | 1.038197 | 21.68 | 15.71 | 0.00868406 | 12.80 | 12.09 | 0.00850000 | 28.87 | 0.01411382 | 22.22 | 0.0000 | 21.11 | 0.00868406 | 55.6743 | 10598.29 | 0.00 | 11932.64 | 11242.73 |
ROOM_5_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 6886.177 | 6886.177 | 0.297027 | 0.00006024 | 196.789 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 6886.18 | 6886.18 | 0.297027 | 21.11 | 14.42 | 0.00748912 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00748912 | 48.1038 | 6886.44 | 0.00 | 7423.46 | 7423.46 |
ROOM_6_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 11581.782 | -999.000 | 1.007817 | 0.00041367 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | unknown | 7/21 09:20:00 | 11581.78 | 11063.97 | 1.007817 | 21.68 | 15.72 | 0.00868969 | 12.80 | 12.09 | 0.00850000 | 28.45 | 0.01411307 | 22.10 | 0.0000 | 21.11 | 0.00868969 | 55.7099 | 10288.16 | 0.00 | 11600.81 | 10916.44 |
ROOM_6_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 6905.402 | 6905.402 | 0.297856 | 0.00006041 | 197.338 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 6905.40 | 6905.40 | 0.297856 | 21.11 | 14.42 | 0.00749046 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00749046 | 48.1123 | 6905.67 | 0.00 | 7444.19 | 7444.19 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | 15090.803 | 15090.803 | 0.794166 | 0.00013202 | 364.607 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 15090.80 | 15090.80 | 0.794166 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00760020 | 49.1412 | 10902.84 | 0.00 | 15169.51 | 15169.51 |
ROOM_1_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 3411.637 | -999.000 | 0.299295 | 0.00012185 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | unknown | 7/21 16:30:00 | 3411.64 | 3282.66 | 0.299295 | 21.68 | 15.69 | 0.00865924 | 12.80 | 12.09 | 0.00850000 | 31.36 | 0.01411830 | 22.93 | 0.0000 | 21.11 | 0.00865924 | 55.5173 | 3055.33 | 0.00 | 3417.29 | 3237.55 |
ROOM_1_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 2085.979 | 2085.979 | 0.089976 | 0.00001825 | 59.609 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 2085.98 | 2085.98 | 0.089976 | 21.11 | 14.50 | 0.00757241 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00757241 | 48.6324 | 2086.06 | 0.00 | 2248.74 | 2248.74 |
ROOM_2_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 3305.010 | -999.000 | 0.289526 | 0.00011805 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | unknown | 7/21 16:40:00 | 3305.01 | 3176.04 | 0.289526 | 21.68 | 15.69 | 0.00866458 | 12.80 | 12.09 | 0.00850000 | 31.26 | 0.01411813 | 22.90 | 0.0000 | 21.11 | 0.00866458 | 55.5511 | 2955.60 | 0.00 | 3310.48 | 3132.62 |
ROOM_2_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 2092.409 | 2092.409 | 0.090254 | 0.00001831 | 59.793 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 2092.41 | 2092.41 | 0.090254 | 21.11 | 14.50 | 0.00757367 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00757367 | 48.6404 | 2092.49 | 0.00 | 2255.67 | 2255.67 |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 15845.974 | -999.000 | 1.368317 | 0.00056597 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | unknown | 7/21 13:20:00 | 15845.97 | 15034.61 | 1.368317 | 21.68 | 15.74 | 0.00871872 | 12.80 | 12.09 | 0.00850000 | 31.85 | 0.01411920 | 23.06 | 0.0000 | 21.11 | 0.00871872 | 55.8938 | 13968.14 | 0.00 | 15871.80 | 14839.91 |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 9911.646 | 9911.646 | 0.427530 | 0.00008671 | 283.233 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 9911.65 | 9911.65 | 0.427530 | 21.11 | 14.51 | 0.00758478 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.11 | 0.00758478 | 48.7104 | 9911.94 | 0.00 | 10685.01 | 10685.01 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 12730.977 | 12730.977 | 1.149122 | 0.00011138 | 281.608 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 12730.98 | 12730.98 | 1.149122 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00766649 | 49.5653 | 6670.79 | 0.00 | 12800.26 | 12800.26 |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 13167.565 | 13167.565 | 1.204237 | 0.00011520 | 290.821 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 13167.56 | 13167.56 | 1.204237 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00767327 | 49.6086 | 6816.64 | 0.00 | 13239.27 | 13239.27 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 8850.444 | 8850.444 | 1.198317 | 0.00007743 | 188.471 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | 8850.44 | 8850.44 | 1.198317 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00672999 | 43.5829 | 2545.68 | 0.00 | 8899.83 | 8899.83 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | 9028.707 | 9028.707 | 0.408987 | 0.00007899 | 226.382 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 9028.71 | 9028.71 | 0.408987 | 16.70 | 13.18 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 21.00 | 0.00771413 | 49.8691 | 6871.56 | 0.00 | 9075.21 | 9075.21 |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | VAV WITH REHEAT | 706034.176 | -999.000 | 21.968809 | 0.02521790 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 706034.18 | 461536.13 | 21.968809 | 28.30 | 20.59 | 0.01203759 | 10.99 | 10.99 | 0.00850000 | 32.10 | 0.01411964 | 23.13 | 53.0819 | 23.99 | 0.00964747 | 51.8377 | 301721.33 | 0.00 | 706838.37 | 456317.62 |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | VAV WITH REHEAT | 218405.541 | 218405.541 | 6.590643 | 0.00191071 | 3604.866 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | 218405.54 | 218405.54 | 6.590643 | -10.70 | -10.70 | 0.00150390 | 16.70 | 13.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 176.9396 | 21.11 | 0.00651826 | 41.9440 | 68907.78 | 0.00 | 187135.77 | 187135.77 |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | FLR_3_DOAS | 86334.709 | -999.000 | 2.051317 | 0.00308368 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 86334.71 | 51162.86 | 2.051317 | 32.10 | 23.13 | 0.01411964 | 11.94 | 11.74 | 0.00850000 | 32.10 | 0.01411964 | 23.13 | 99.9965 | 21.11 | 0.00871743 | 55.8841 | 177906.93 | 0.00 | 86433.83 | 51479.65 |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | AirLoopHVAC | FLR_3_DOAS | 20393.415 | 20393.415 | 0.615395 | 0.00017841 | 336.601 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 20393.42 | 20393.42 | 0.615395 | -10.70 | -10.70 | 0.00150390 | 16.70 | 13.18 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 333.3216 | 21.11 | 0.00752643 | 48.3395 | 120977.96 | 0.00 | 17473.63 | 17473.63 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | BASEMENT | N/A | N/A | N/A | Yes | Yes | Yes | No | 7014.406 | 7014.406 | 1.329122 | 0.00006137 | 146.273 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.4017 | 1.429908 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | Sensible | 7014.41 | 7014.41 | 1.0000 | 1.59972403 | 1.329122 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.06135882 | 60.00 | 32.22 | 27.78 | 0.000 | 7014.41 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 51.6928 | 0.00 | 0.00 | 7053.83 | 7053.83 | 1.59972403 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 20.92 | 14.82 | 0.00800000 | 41344.1 | |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | RETAIL_1_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 4102.092 | 4102.092 | 0.205138 | 0.00003589 | 100.287 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.8197 | 0.836224 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 4102.09 | 4102.09 | 1.0000 | 0.24690267 | 0.205138 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.03588323 | 60.00 | 32.22 | 27.78 | 0.000 | 4102.09 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00749491 | 21.00 | 0.00749491 | 48.4711 | 3020.75 | 0.00 | 4123.39 | 4123.39 | 0.24690267 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 32.98 | 19.01 | 0.00800000 | 53635.2 | |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | RETAIL_2_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1721.569 | 1721.569 | 0.126894 | 0.00001506 | 39.112 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.3440 | 0.350947 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 1721.57 | 1721.57 | 1.0000 | 0.15272844 | 0.126894 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.01505950 | 60.00 | 32.22 | 27.78 | 0.000 | 1721.57 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00744508 | 21.00 | 0.00744508 | 48.1507 | 1052.63 | 0.00 | 1730.84 | 1730.84 | 0.15272844 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 27.71 | 17.26 | 0.00800000 | 48267.5 | |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | MECH_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2604.154 | 2604.154 | 0.123304 | 0.00002278 | 64.535 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.5204 | 0.530865 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 2604.15 | 2604.15 | 1.0000 | 0.14840763 | 0.123304 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.02277995 | 60.00 | 32.22 | 27.78 | 0.000 | 2604.15 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00730966 | 21.00 | 0.00730966 | 47.2852 | 1954.31 | 0.00 | 2617.61 | 2617.61 | 0.14840763 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 33.90 | 19.31 | 0.00800000 | 54572.7 | |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | STORAGE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1495.163 | 1495.163 | 0.059757 | 0.00001308 | 38.907 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.2988 | 0.304794 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 1495.16 | 1495.16 | 1.0000 | 0.07192375 | 0.059757 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.01307901 | 60.00 | 32.22 | 27.78 | 0.000 | 1495.16 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00733734 | 21.00 | 0.00733734 | 47.4622 | 1180.21 | 0.00 | 1502.68 | 1502.68 | 0.07192375 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 37.09 | 20.31 | 0.00800000 | 57827.5 | |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LAUNDRY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11674.169 | 11674.169 | 1.723482 | 0.00010213 | 247.080 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 2.3329 | 2.379815 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 11674.17 | 11674.17 | 1.0000 | 2.07437451 | 1.723482 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.10212030 | 60.00 | 32.22 | 27.78 | 0.000 | 11674.17 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00729176 | 21.00 | 0.00729176 | 47.1727 | 2592.62 | 0.00 | 11739.44 | 11739.44 | 2.07437451 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 22.15 | 15.28 | 0.00800000 | 42594.0 | |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | CAFE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11909.289 | 11909.289 | 0.827817 | 0.00010419 | 273.007 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 2.3798 | 2.427745 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 11909.29 | 11909.29 | 1.0000 | 0.99635667 | 0.827817 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.10417703 | 60.00 | 32.22 | 27.78 | 0.000 | 11909.29 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00754895 | 21.00 | 0.00754895 | 48.8158 | 7544.97 | 0.00 | 11973.24 | 11973.24 | 0.99635667 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 28.38 | 17.49 | 0.00800000 | 48951.8 | |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LOBBY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 31385.415 | 31385.415 | 2.513950 | 0.00027457 | 704.718 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 6.2718 | 6.398012 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 31385.41 | 31385.41 | 1.0000 | 3.02577785 | 2.513950 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.27454529 | 60.00 | 32.22 | 27.78 | 0.000 | 31385.41 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00747062 | 21.00 | 0.00747062 | 48.3139 | 18132.10 | 0.00 | 31555.21 | 31555.21 | 3.02577785 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 26.83 | 16.96 | 0.00800000 | 47363.5 | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13017.001 | -999.000 | 1.139574 | 0.00046493 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9516 | 1004.8586 | 1.2036 | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.139574 | 1.37158554 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 1.2936 | 1.293588 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | unknown | unknown | unknown | 7/21 16:30:00 | Sensible | 13017.00 | 12501.80 | 1.0000 | 1.37158554 | 1.139574 | 21.68 | 15.70 | 0.00866703 | 43812.7 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.46488102 | 6.70 | 13.37 | 6.67 | 0.000 | 13017.00 | 31.36 | 0.01411830 | 22.93 | 0.00000000 | 0.0000 | 21.11 | 0.00866703 | 21.11 | 0.00866703 | 55.5666 | 11633.22 | 0.00 | 13038.53 | 12331.29 | 1.37158554 | 21.68 | 15.70 | 0.00866703 | 43812.7 | 12.88 | 12.09 | 0.00846281 | 34306.5 | |
ROOM_1_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6925.284 | 6925.284 | 0.298714 | 0.00006059 | 197.906 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.139574 | 1.37158554 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.3839 | 1.411740 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 6925.28 | 6925.28 | 1.0000 | 0.35953050 | 0.298714 | 21.11 | 14.42 | 0.00749178 | 40243.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.06057923 | 60.00 | 32.22 | 27.78 | 0.000 | 6925.28 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00749178 | 21.11 | 0.00749178 | 48.1206 | 6925.55 | 0.00 | 7465.62 | 7465.62 | 0.35953050 | 16.60 | 12.65 | 0.00749178 | 35648.0 | 36.98 | 19.89 | 0.00749178 | 56412.9 | |
ROOM_2_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 12636.230 | -999.000 | 1.104677 | 0.00045133 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9614 | 1004.8586 | 1.2036 | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.104677 | 1.32958387 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 1.2558 | 1.255748 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | unknown | unknown | unknown | 7/21 16:40:00 | Sensible | 12636.23 | 12120.92 | 1.0000 | 1.32958387 | 1.104677 | 21.68 | 15.70 | 0.00867231 | 43826.1 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.45128238 | 6.70 | 13.37 | 6.67 | 0.000 | 12636.23 | 31.26 | 0.01411813 | 22.90 | 0.00000000 | 0.0000 | 21.11 | 0.00867231 | 21.11 | 0.00867231 | 55.6000 | 11276.97 | 0.00 | 12657.09 | 11956.47 | 1.32958387 | 21.68 | 15.71 | 0.00867231 | 43826.1 | 12.87 | 12.09 | 0.00846361 | 34306.5 | |
ROOM_2_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6944.493 | 6944.493 | 0.299542 | 0.00006075 | 198.455 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.104677 | 1.32958387 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.3877 | 1.415656 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 6944.49 | 6944.49 | 1.0000 | 0.36052772 | 0.299542 | 21.11 | 14.42 | 0.00749311 | 40246.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.06074726 | 60.00 | 32.22 | 27.78 | 0.000 | 6944.49 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00749311 | 21.11 | 0.00749311 | 48.1291 | 6944.76 | 0.00 | 7486.33 | 7486.33 | 0.36052772 | 16.60 | 12.66 | 0.00749311 | 35651.4 | 36.98 | 19.89 | 0.00749311 | 56416.3 | |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 73181.758 | -999.000 | 6.530630 | 0.00261383 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8193 | 1004.8586 | 1.2036 | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 6.530630 | 7.86023347 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 7.2727 | 7.272569 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | unknown | unknown | unknown | 7/21 13:20:00 | Sensible | 73181.76 | 71490.99 | 1.0000 | 7.86023347 | 6.530630 | 21.68 | 15.63 | 0.00859586 | 43632.6 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 2.61356740 | 6.70 | 13.37 | 6.67 | 0.000 | 73181.76 | 31.85 | 0.01411920 | 23.06 | 0.00000000 | 0.0000 | 21.11 | 0.00859586 | 21.11 | 0.00859586 | 55.1143 | 66672.55 | 0.00 | 73305.31 | 70446.21 | 7.86023347 | 21.68 | 15.64 | 0.00859586 | 43632.6 | 12.90 | 12.09 | 0.00845180 | 34306.5 | |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 39426.227 | 39426.227 | 1.700612 | 0.00034492 | 1126.675 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 6.530630 | 7.86023347 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 7.8786 | 8.037156 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 39426.23 | 39426.23 | 1.0000 | 2.04684781 | 1.700612 | 21.11 | 14.45 | 0.00752418 | 40325.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.34488264 | 60.00 | 32.22 | 27.78 | 0.000 | 39426.23 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00752418 | 21.11 | 0.00752418 | 48.3260 | 39426.75 | 0.00 | 42502.48 | 42502.48 | 2.04684781 | 16.60 | 12.69 | 0.00752418 | 35730.0 | 36.98 | 19.91 | 0.00752418 | 56494.9 | |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 68994.926 | -999.000 | 5.760697 | 0.00246429 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2885 | 1004.8586 | 1.2036 | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 5.760697 | 6.93354637 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 6.8566 | 6.856495 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | unknown | unknown | unknown | 7/21 15:00:00 | Sensible | 68994.93 | 63535.34 | 1.0000 | 6.93354637 | 5.760697 | 21.68 | 15.85 | 0.00884827 | 44273.1 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 2.46404148 | 6.70 | 13.37 | 6.67 | 0.000 | 68994.93 | 32.10 | 0.01411964 | 23.13 | 0.00000000 | 0.0000 | 21.11 | 0.00884827 | 21.11 | 0.00884827 | 56.7122 | 58807.60 | 0.00 | 69103.54 | 62817.72 | 6.93354637 | 21.68 | 15.86 | 0.00884827 | 44273.1 | 12.81 | 12.09 | 0.00848919 | 34306.5 | |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 39798.129 | 39798.129 | 1.716653 | 0.00034817 | 1137.300 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 5.760697 | 6.93354637 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 7.9529 | 8.112970 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 39798.13 | 39798.13 | 1.0000 | 2.06615547 | 1.716653 | 21.11 | 14.45 | 0.00752818 | 40335.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.34813588 | 60.00 | 32.22 | 27.78 | 0.000 | 39798.13 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00752818 | 21.11 | 0.00752818 | 48.3514 | 39798.66 | 0.00 | 42903.40 | 42903.40 | 2.06615547 | 16.60 | 12.69 | 0.00752818 | 35740.2 | 36.98 | 19.92 | 0.00752818 | 56505.0 | |
ROOM_5_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11913.040 | -999.000 | 1.038197 | 0.00042550 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9832 | 1004.8586 | 1.2036 | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.038197 | 1.24956820 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 1.1839 | 1.183880 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:40:00 | unknown | unknown | unknown | 7/21 09:40:00 | Sensible | 11913.04 | 11395.54 | 1.0000 | 1.24956820 | 1.038197 | 21.68 | 15.71 | 0.00868406 | 43855.9 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.42545482 | 6.70 | 13.37 | 6.67 | 0.000 | 11913.04 | 28.87 | 0.01411382 | 22.22 | 0.00000000 | 0.0000 | 21.11 | 0.00868406 | 21.11 | 0.00868406 | 55.6743 | 10598.29 | 0.00 | 11932.64 | 11242.73 | 1.24956820 | 21.68 | 15.72 | 0.00868406 | 43855.9 | 12.87 | 12.09 | 0.00846538 | 34306.5 | |
ROOM_5_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6886.177 | 6886.177 | 0.297027 | 0.00006024 | 196.789 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.038197 | 1.24956820 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.3761 | 1.403768 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 6886.18 | 6886.18 | 1.0000 | 0.35750020 | 0.297027 | 21.11 | 14.42 | 0.00748912 | 40236.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.06023713 | 60.00 | 32.22 | 27.78 | 0.000 | 6886.18 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00748912 | 21.11 | 0.00748912 | 48.1038 | 6886.44 | 0.00 | 7423.46 | 7423.46 | 0.35750020 | 16.60 | 12.65 | 0.00748912 | 35641.3 | 36.98 | 19.89 | 0.00748912 | 56406.2 | |
ROOM_6_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11581.782 | -999.000 | 1.007817 | 0.00041367 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9937 | 1004.8586 | 1.2036 | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.007817 | 1.21300331 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 1.1510 | 1.150960 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | unknown | unknown | unknown | 7/21 09:20:00 | Sensible | 11581.78 | 11063.97 | 1.0000 | 1.21300331 | 1.007817 | 21.68 | 15.72 | 0.00868969 | 43870.2 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.41362448 | 6.70 | 13.37 | 6.67 | 0.000 | 11581.78 | 28.45 | 0.01411307 | 22.10 | 0.00000000 | 0.0000 | 21.11 | 0.00868969 | 21.11 | 0.00868969 | 55.7099 | 10288.16 | 0.00 | 11600.81 | 10916.44 | 1.21300331 | 21.68 | 15.72 | 0.00868969 | 43870.2 | 12.87 | 12.09 | 0.00846623 | 34306.5 | |
ROOM_6_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6905.402 | 6905.402 | 0.297856 | 0.00006041 | 197.338 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.007817 | 1.21300331 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.3799 | 1.407687 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 6905.40 | 6905.40 | 1.0000 | 0.35849827 | 0.297856 | 21.11 | 14.42 | 0.00749046 | 40239.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.06040530 | 60.00 | 32.22 | 27.78 | 0.000 | 6905.40 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00749046 | 21.11 | 0.00749046 | 48.1123 | 6905.67 | 0.00 | 7444.19 | 7444.19 | 0.35849827 | 16.60 | 12.65 | 0.00749046 | 35644.7 | 36.98 | 19.89 | 0.00749046 | 56409.6 | |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | CORRIDOR_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 15090.803 | 15090.803 | 0.794166 | 0.00013202 | 364.607 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 3.0156 | 3.076306 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 15090.80 | 15090.80 | 1.0000 | 0.95585458 | 0.794166 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.13200746 | 60.00 | 32.22 | 27.78 | 0.000 | 15090.80 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00760020 | 21.00 | 0.00760020 | 49.1412 | 10902.84 | 0.00 | 15169.51 | 15169.51 | 0.95585458 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 32.16 | 18.75 | 0.00800000 | 52804.8 | |
ROOM_1_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3411.637 | -999.000 | 0.299295 | 0.00012185 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9371 | 1004.8586 | 1.2036 | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.299295 | 0.36023023 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 0.3390 | 0.339038 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | unknown | unknown | unknown | 7/21 16:30:00 | Sensible | 3411.64 | 3282.66 | 1.0000 | 0.36023023 | 0.299295 | 21.68 | 15.69 | 0.00865924 | 43792.9 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.12184105 | 6.70 | 13.37 | 6.67 | 0.000 | 3411.64 | 31.36 | 0.01411830 | 22.93 | 0.00000000 | 0.0000 | 21.11 | 0.00865924 | 21.11 | 0.00865924 | 55.5173 | 3055.33 | 0.00 | 3417.29 | 3237.55 | 0.36023023 | 21.68 | 15.69 | 0.00865924 | 43792.9 | 12.88 | 12.09 | 0.00846162 | 34306.5 | |
ROOM_1_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2085.979 | 2085.979 | 0.089976 | 0.00001825 | 59.609 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.299295 | 0.36023023 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.4168 | 0.425233 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 2085.98 | 2085.98 | 1.0000 | 0.10829493 | 0.089976 | 21.11 | 14.50 | 0.00757241 | 40447.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.01824720 | 60.00 | 32.22 | 27.78 | 0.000 | 2085.98 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00757241 | 21.11 | 0.00757241 | 48.6324 | 2086.06 | 0.00 | 2248.74 | 2248.74 | 0.10829493 | 16.60 | 12.73 | 0.00757241 | 35852.2 | 36.98 | 19.95 | 0.00757241 | 56617.1 | |
ROOM_2_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3305.010 | -999.000 | 0.289526 | 0.00011805 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9470 | 1004.8586 | 1.2036 | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.289526 | 0.34847260 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 0.3284 | 0.328441 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | unknown | unknown | unknown | 7/21 16:40:00 | Sensible | 3305.01 | 3176.04 | 1.0000 | 0.34847260 | 0.289526 | 21.68 | 15.69 | 0.00866458 | 43806.5 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.11803305 | 6.70 | 13.37 | 6.67 | 0.000 | 3305.01 | 31.26 | 0.01411813 | 22.90 | 0.00000000 | 0.0000 | 21.11 | 0.00866458 | 21.11 | 0.00866458 | 55.5511 | 2955.60 | 0.00 | 3310.48 | 3132.62 | 0.34847260 | 21.68 | 15.70 | 0.00866458 | 43806.5 | 12.88 | 12.09 | 0.00846243 | 34306.5 | |
ROOM_2_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2092.409 | 2092.409 | 0.090254 | 0.00001831 | 59.793 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.289526 | 0.34847260 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 0.4181 | 0.426544 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 2092.41 | 2092.41 | 1.0000 | 0.10862871 | 0.090254 | 21.11 | 14.50 | 0.00757367 | 40451.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.01830344 | 60.00 | 32.22 | 27.78 | 0.000 | 2092.41 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00757367 | 21.11 | 0.00757367 | 48.6404 | 2092.49 | 0.00 | 2255.67 | 2255.67 | 0.10862871 | 16.60 | 12.73 | 0.00757367 | 35855.4 | 36.98 | 19.95 | 0.00757367 | 56620.3 | |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 15845.974 | -999.000 | 1.368317 | 0.00056597 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.0477 | 1004.8586 | 1.2036 | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.368317 | 1.64690000 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 1.5748 | 1.574722 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | unknown | unknown | unknown | 7/21 13:20:00 | Sensible | 15845.97 | 15034.61 | 1.0000 | 1.64690000 | 1.368317 | 21.68 | 15.74 | 0.00871872 | 43943.9 | 12.80 | 12.09 | 0.00850000 | 34322.2 | 0.56591316 | 6.70 | 13.37 | 6.67 | 0.000 | 15845.97 | 31.85 | 0.01411920 | 23.06 | 0.00000000 | 0.0000 | 21.11 | 0.00871872 | 21.11 | 0.00871872 | 55.8938 | 13968.14 | 0.00 | 15871.80 | 14839.91 | 1.64690000 | 21.68 | 15.75 | 0.00871872 | 43943.9 | 12.86 | 12.09 | 0.00847057 | 34306.5 | |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 9911.646 | 9911.646 | 0.427530 | 0.00008671 | 283.233 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.368317 | 1.64690000 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.9807 | 2.020519 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 9911.65 | 9911.65 | 1.0000 | 0.51457278 | 0.427530 | 21.11 | 14.51 | 0.00758478 | 40479.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.08670256 | 60.00 | 32.22 | 27.78 | 0.000 | 9911.65 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.11 | 0.00758478 | 21.11 | 0.00758478 | 48.7104 | 9911.94 | 0.00 | 10685.01 | 10685.01 | 0.51457278 | 16.60 | 12.75 | 0.00758478 | 35883.5 | 36.98 | 19.96 | 0.00758478 | 56648.3 | |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | BANQUET_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 12730.977 | 12730.977 | 1.149122 | 0.00011138 | 281.608 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 2.5440 | 2.595248 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 12730.98 | 12730.98 | 1.0000 | 1.38307756 | 1.149122 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.11136478 | 60.00 | 32.22 | 27.78 | 0.000 | 12730.98 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00766649 | 21.00 | 0.00766649 | 49.5653 | 6670.79 | 0.00 | 12800.26 | 12800.26 | 1.38307756 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 25.68 | 16.55 | 0.00800000 | 46189.6 | |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | DINING_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13167.565 | 13167.565 | 1.204237 | 0.00011520 | 290.821 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 2.6313 | 2.684248 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 13167.56 | 13167.56 | 1.0000 | 1.44941302 | 1.204237 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.11518385 | 60.00 | 32.22 | 27.78 | 0.000 | 13167.56 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00767327 | 21.00 | 0.00767327 | 49.6086 | 6816.64 | 0.00 | 13239.27 | 13239.27 | 1.44941302 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 25.56 | 16.51 | 0.00800000 | 46069.0 | |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | KITCHEN_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8850.444 | 8850.444 | 1.198317 | 0.00007743 | 188.471 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.7686 | 1.804190 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | Sensible | 8850.44 | 8850.44 | 1.0000 | 1.44228774 | 1.198317 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.07741965 | 60.00 | 32.22 | 27.78 | 0.000 | 8850.44 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 20.60 | 0.00672999 | 21.00 | 0.00672999 | 43.5829 | 2545.68 | 0.00 | 8899.83 | 8899.83 | 1.44228774 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 22.65 | 15.46 | 0.00800000 | 43105.4 | |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | CORRIDOR_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 9028.707 | 9028.707 | 0.408987 | 0.00007899 | 226.382 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 1.8042 | 1.840529 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 9028.71 | 9028.71 | 1.0000 | 0.49225458 | 0.408987 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | 0.07897901 | 60.00 | 32.22 | 27.78 | 0.000 | 9028.71 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 21.00 | 0.00771413 | 21.00 | 0.00771413 | 49.8691 | 6871.56 | 0.00 | 9075.21 | 9075.21 | 0.49225458 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 34.68 | 19.56 | 0.00800000 | 55370.7 | |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 706034.176 | -999.000 | 21.968809 | 0.02521790 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1027.2173 | 1004.8586 | 1.2036 | VAV WITH REHEAT FAN | Fan:VariableVolume | 21.968809 | 26.44154855 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 70.1647 | 70.164730 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | Sensible | 706034.18 | 461536.13 | 1.0000 | 26.44154855 | 21.968809 | 28.30 | 20.59 | 0.01203759 | 59174.2 | 10.99 | 10.99 | 0.00850000 | 32472.5 | 25.21533240 | 6.70 | 13.37 | 6.67 | 49224.162 | 656810.01 | 32.10 | 0.01411964 | 23.13 | 11.66146000 | 53.0819 | 23.99 | 0.00967707 | 23.99 | 0.00964747 | 51.8377 | 301721.33 | 0.00 | 706838.37 | 456317.62 | 26.44154855 | 28.30 | 20.60 | 0.01203759 | 59174.2 | 11.50 | 11.33 | 0.00828132 | 32442.1 | |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 218405.541 | 218405.541 | 6.590643 | 0.00191071 | 3604.866 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | VAV WITH REHEAT FAN | Fan:VariableVolume | 21.968809 | 26.44154855 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 43.6443 | 44.522635 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 23:40:00 | Sensible | 218405.54 | 218405.54 | 1.0000 | 7.93246457 | 6.590643 | -10.70 | -10.70 | 0.00150390 | -7020.5 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 1.91051204 | 60.00 | 32.22 | 27.78 | 0.000 | 218405.54 | -10.70 | 0.00150390 | -10.70 | 11.66146000 | 176.9396 | 18.56 | 0.00683037 | 21.11 | 0.00651826 | 41.9440 | 68907.78 | 0.00 | 187135.77 | 187135.77 | 7.93246457 | 2.80 | -1.97 | 0.00150390 | 6582.5 | 26.21 | 10.51 | 0.00150390 | 30173.7 | |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 86334.709 | -999.000 | 2.051317 | 0.00308368 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1031.0877 | 1004.8586 | 1.2036 | FLR_3_DOAS FAN | Fan:ConstantVolume | 2.051245 | 2.46886833 | 4197.9300 | 999.8980 | 35.93733243 | 13.37 | 6.70 | 6.67 | 1006252.25 | 8.5798 | 8.579828 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | Sensible | 86334.71 | 51162.86 | 1.0000 | 2.46895513 | 2.051317 | 32.10 | 23.13 | 0.01411964 | 68410.3 | 11.94 | 11.74 | 0.00850000 | 33442.2 | 3.08336118 | 6.70 | 13.37 | 6.67 | 2195.006 | 84139.70 | 32.10 | 0.01411964 | 23.13 | 2.05124512 | 99.9965 | 21.11 | 0.00871680 | 21.11 | 0.00871743 | 55.8841 | 177906.93 | 0.00 | 86433.83 | 51479.65 | 2.46895513 | 32.10 | 23.14 | 0.01411964 | 68410.3 | 11.88 | 11.73 | 0.00850831 | 33402.0 | |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 20393.415 | 20393.415 | 0.615395 | 0.00017841 | 336.601 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | FLR_3_DOAS FAN | Fan:ConstantVolume | 2.051245 | 2.46886833 | 4197.9300 | 999.8980 | 4.29110285 | 54.44 | 82.22 | 27.78 | 500421.96 | 4.0752 | 4.157260 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 20393.42 | 20393.42 | 1.0000 | 0.74068654 | 0.615395 | -10.70 | -10.70 | 0.00150390 | -7020.5 | 16.70 | 13.18 | 0.00800000 | 37036.7 | 0.17839229 | 60.00 | 32.22 | 27.78 | 0.000 | 20393.42 | -10.70 | 0.00150390 | -10.70 | 2.05124512 | 333.3216 | 21.11 | 0.00752458 | 21.11 | 0.00752643 | 48.3395 | 120977.96 | 0.00 | 17473.63 | 17473.63 | 0.74068654 | 2.80 | -1.97 | 0.00150390 | 6582.5 | 26.21 | 10.51 | 0.00150390 | 30173.7 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
VAV WITH REHEAT_OA_CONTROLLER | DifferentialEnthalpy | 11.66 | 21.97 | - | |||
FLR_3_DOAS_OA_CONTROLLER | DifferentialDryBulb | 2.05 | 2.05 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
BASEMENT | VAV WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
RETAIL_1_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
RETAIL_2_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
MECH_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
STORAGE_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000610 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
LAUNDRY_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CAFE_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
LOBBY_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001448 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORRIDOR_FLR_3 | VAV WITH REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
BANQUET_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
DINING_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
KITCHEN_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003556 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORRIDOR_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BASEMENT | 830.83 | 6342.33 | 0.00 |
RETAIL_1_FLR_1 | 2625.67 | 6551.33 | 1152.67 |
RETAIL_2_FLR_1 | 1855.00 | 6078.67 | 128.00 |
MECH_FLR_1 | 1355.33 | 6982.17 | 659.17 |
STORAGE_FLR_1 | 1187.83 | 7473.67 | 887.83 |
LAUNDRY_FLR_1 | 6854.33 | 3429.00 | 2641.33 |
CAFE_FLR_1 | 3536.00 | 5623.50 | 1130.33 |
LOBBY_FLR_1 | 2931.67 | 5698.33 | 865.17 |
ROOM_1_FLR_3 | 2628.67 | 8109.83 | 2416.67 |
ROOM_2_FLR_3 | 3082.17 | 8274.50 | 2955.17 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 2211.00 | 8760.00 | 2211.00 |
ROOM_5_FLR_3 | 2455.50 | 8033.33 | 2358.33 |
ROOM_6_FLR_3 | 2897.00 | 8215.83 | 2871.83 |
CORRIDOR_FLR_3 | 1305.33 | 6992.00 | 635.50 |
ROOM_1_FLR_6 | 3275.00 | 8049.67 | 2962.33 |
ROOM_2_FLR_6 | 3630.00 | 8205.33 | 3437.83 |
ROOM_3_MULT9_FLR_6 | 1950.50 | 8045.17 | 1748.83 |
BANQUET_FLR_6 | 4385.17 | 3487.17 | 857.67 |
DINING_FLR_6 | 5052.00 | 2450.00 | 768.00 |
KITCHEN_FLR_6 | 8111.67 | 6520.17 | 6241.50 |
CORRIDOR_FLR_6 | 2168.50 | 6501.50 | 679.67 |
Facility | 8758.50 | 8760.00 | 8133.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 0.00 | 142.17 | 0.00 | 142.17 |
CAFE_FLR_1 | 0.00 | 0.50 | 0.00 | 0.50 |
LOBBY_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 0.00 | 11.17 | 0.00 | 11.17 |
ROOM_2_FLR_3 | 0.00 | 5.83 | 0.00 | 5.83 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 2.50 | 10.00 | 2.50 | 10.00 |
ROOM_5_FLR_3 | 0.00 | 3.50 | 0.00 | 3.50 |
ROOM_6_FLR_3 | 0.00 | 3.50 | 0.00 | 3.50 |
CORRIDOR_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 0.00 | 15.50 | 0.00 | 15.50 |
ROOM_2_FLR_6 | 0.00 | 8.00 | 0.00 | 8.00 |
ROOM_3_MULT9_FLR_6 | 0.00 | 9.83 | 0.00 | 9.83 |
BANQUET_FLR_6 | 0.00 | 21.17 | 0.00 | 21.17 |
DINING_FLR_6 | 0.00 | 28.83 | 0.00 | 28.83 |
KITCHEN_FLR_6 | 0.00 | 237.50 | 0.00 | 237.50 |
CORRIDOR_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 2.50 | 310.50 | 2.50 | 310.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.79 | 106.50 | 4826.41 | 0.965 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 2.654 | 0.137 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 1.411 | 0.046 | 0.000 | 0.000 |
MECH_FLR_1 | 1.54 | 2.65 | 650.80 | 0.640 | 0.051 | 0.000 | 0.000 |
STORAGE_FLR_1 | 1.18 | 2.04 | 375.47 | 0.535 | 0.051 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 21.491 | 0.147 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.56 | 142.30 | 748.35 | 3.843 | 0.108 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.09 | 422.44 | 5183.56 | 1.699 | 0.045 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.472 | 0.177 | 0.000 | 0.065 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.472 | 0.177 | 0.000 | 0.063 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.536 | 0.079 | 0.000 | 0.100 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.472 | 0.178 | 0.000 | 0.065 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.472 | 0.177 | 0.000 | 0.063 |
CORRIDOR_FLR_3 | 12.16 | 20.96 | 1186.91 | 0.565 | 0.022 | 0.000 | 0.000 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.472 | 0.178 | 0.000 | 0.079 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.472 | 0.177 | 0.000 | 0.077 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.537 | 0.145 | 0.000 | 0.126 |
BANQUET_FLR_6 | 144.99 | 249.90 | 1010.89 | 4.499 | 0.052 | 0.000 | 0.000 |
DINING_FLR_6 | 144.99 | 249.90 | 1010.89 | 4.839 | 0.052 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 20.112 | 0.148 | 0.000 | 0.000 |
CORRIDOR_FLR_6 | 12.87 | 22.18 | 1256.16 | 1.109 | 0.036 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.79 | 106.50 | 4826.41 | 0.589 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 1.563 | 0.002 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 0.839 | 0.001 | 0.000 | 0.000 |
MECH_FLR_1 | 1.54 | 2.65 | 650.80 | 0.384 | 0.001 | 0.000 | 0.000 |
STORAGE_FLR_1 | 1.18 | 2.04 | 375.47 | 0.322 | 0.001 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 11.643 | 0.002 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.56 | 142.30 | 748.35 | 2.300 | 0.002 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.09 | 422.44 | 5183.56 | 1.037 | 0.001 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.453 | 0.003 | 0.000 | 0.000 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.452 | 0.003 | 0.000 | 0.000 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.514 | 0.001 | 0.000 | 0.000 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.454 | 0.003 | 0.000 | 0.000 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.452 | 0.003 | 0.000 | 0.000 |
CORRIDOR_FLR_3 | 12.16 | 20.96 | 1186.91 | 0.339 | 0.000 | 0.000 | 0.000 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.453 | 0.003 | 0.000 | 0.000 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.452 | 0.003 | 0.000 | 0.000 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.516 | 0.002 | 0.000 | 0.000 |
BANQUET_FLR_6 | 144.99 | 249.90 | 1010.89 | 2.765 | 0.001 | 0.000 | 0.000 |
DINING_FLR_6 | 144.99 | 249.90 | 1010.89 | 3.028 | 0.001 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 7.975 | 0.002 | 0.000 | 0.000 |
CORRIDOR_FLR_6 | 12.87 | 22.18 | 1256.16 | 0.658 | 0.001 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
BASEMENT | VAV WITH REHEAT | 61.79 | 106.50 | 4826.41 | 1978.83 | 0.0000 | 0.854 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | 6.28 | 10.83 | 265.76 | 67.07 | 0.0000 | 0.079 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | 7.28 | 12.54 | 307.76 | 77.67 | 0.0000 | 0.092 |
MECH_FLR_1 | VAV WITH REHEAT | 1.54 | 2.65 | 650.80 | 164.24 | 0.0000 | 0.000 |
STORAGE_FLR_1 | VAV WITH REHEAT | 1.18 | 2.04 | 375.47 | 94.76 | 0.0000 | 0.058 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | 4.87 | 8.40 | 309.22 | 78.04 | 0.0000 | 0.000 |
CAFE_FLR_1 | VAV WITH REHEAT | 82.56 | 142.30 | 748.35 | 188.86 | 0.0000 | 0.676 |
LOBBY_FLR_1 | VAV WITH REHEAT | 245.09 | 422.44 | 5183.56 | 1308.19 | 0.0000 | 1.894 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.062 |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.062 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 1.50 | 74.75 | 24.52 | 0.0000 | 0.837 | |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 74.77 | 24.53 | 0.0000 | 0.837 |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.062 |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.062 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | 12.16 | 20.96 | 1186.91 | 389.40 | 0.0000 | 0.475 |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.015 |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.015 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 74.77 | 24.53 | 0.0000 | 0.099 |
BANQUET_FLR_6 | VAV WITH REHEAT | 144.99 | 249.90 | 1010.89 | 331.66 | 0.0000 | 1.188 |
DINING_FLR_6 | VAV WITH REHEAT | 144.99 | 249.90 | 1010.89 | 331.66 | 0.0000 | 1.188 |
KITCHEN_FLR_6 | VAV WITH REHEAT | 12.90 | 22.24 | 314.87 | 103.30 | 0.0000 | 0.367 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | 12.87 | 22.18 | 1256.16 | 412.12 | 0.0000 | 0.126 |
Total Facility | 873.25 | 1604.23 | 35184.81 | 11345.29 | 0.0000 | 137.584 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
BASEMENT | 40053317.57 | 0.00 | 40053317.57 | 0.00 | 40053317.57 | 26946214.98 | 2.73 | 2.19 | 8755.08 | 0.00 |
RETAIL_1_FLR_1 | 6096370.29 | 0.00 | 6096370.29 | 315162.19 | 6411532.47 | 2498216.28 | 0.00 | 0.00 | 8760.00 | 0.00 |
RETAIL_2_FLR_1 | 3743198.29 | 0.00 | 3743198.29 | 121653.00 | 3864851.29 | 2892943.94 | 78.13 | 16.54 | 8665.33 | 0.00 |
MECH_FLR_1 | 3601474.47 | 0.00 | 3601474.47 | 287515.42 | 3888989.90 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
STORAGE_FLR_1 | 1736431.62 | 0.00 | 1736431.62 | 165880.56 | 1902312.19 | 1821682.01 | 5416.36 | 447.81 | 2895.83 | 0.00 |
LAUNDRY_FLR_1 | 57257952.50 | 0.00 | 57257952.50 | 392587.63 | 57650540.13 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
CAFE_FLR_1 | 24751228.53 | 0.00 | 24751228.53 | 696683.85 | 25447912.38 | 21330615.53 | 740.36 | 202.72 | 7816.92 | 0.00 |
LOBBY_FLR_1 | 75699269.51 | 0.00 | 75699269.51 | 1990584.90 | 77689854.40 | 59728886.00 | 85.71 | 28.88 | 8645.41 | 0.00 |
ROOM_1_FLR_3 | 1946875.62 | 66743.16 | 2013618.78 | 182929.66 | 2196548.44 | 1946875.62 | 0.00 | 7864.33 | 895.67 | 0.00 |
ROOM_2_FLR_3 | 1946647.51 | 64776.25 | 2011423.76 | 182915.70 | 2194339.47 | 1946647.51 | 0.00 | 7864.33 | 895.67 | 0.00 |
ROOM_3_MULT19_FLR_3 | 26397887.27 | 69939.60 | 26467826.88 | 51039.43 | 26518866.30 | 26397887.27 | 0.00 | 7879.17 | 880.83 | 8760.00 |
ROOM_4_MULT19_FLR_3 | 26405105.73 | 64485.06 | 26469590.79 | 51053.38 | 26520644.18 | 26405105.73 | 0.00 | 7891.35 | 868.65 | 0.00 |
ROOM_5_FLR_3 | 1946875.62 | 66809.53 | 2013685.15 | 182929.66 | 2196614.81 | 1946875.62 | 0.00 | 7864.33 | 895.67 | 0.00 |
ROOM_6_FLR_3 | 1946647.51 | 64825.78 | 2011473.29 | 182915.70 | 2194388.99 | 1946647.51 | 0.00 | 7864.33 | 895.67 | 0.00 |
CORRIDOR_FLR_3 | 23133824.93 | 0.00 | 23133824.93 | 221198.76 | 23355023.69 | 14972100.18 | 1.44 | 0.92 | 8757.65 | 0.00 |
ROOM_1_FLR_6 | 486718.90 | 81257.65 | 567976.55 | 182967.83 | 750944.38 | 486718.90 | 0.00 | 7861.17 | 898.83 | 0.00 |
ROOM_2_FLR_6 | 486661.88 | 78683.38 | 565345.26 | 182953.87 | 748299.13 | 486661.88 | 0.00 | 7861.17 | 898.83 | 0.00 |
ROOM_3_MULT9_FLR_6 | 3126920.42 | 81221.33 | 3208141.74 | 93612.75 | 3301754.49 | 3126920.42 | 0.00 | 7861.36 | 898.64 | 0.00 |
BANQUET_FLR_6 | 38983179.72 | 0.00 | 38983179.72 | 446761.45 | 39429941.17 | 37458366.31 | 4799.61 | 342.25 | 3618.14 | 0.00 |
DINING_FLR_6 | 41927083.45 | 0.00 | 41927083.45 | 446761.45 | 42373844.90 | 37458366.31 | 2740.94 | 236.74 | 5782.33 | 0.00 |
KITCHEN_FLR_6 | 54298244.60 | 0.00 | 54298244.60 | 399955.08 | 54698199.68 | 11584760.86 | 0.00 | 0.00 | 8760.00 | 0.00 |
CORRIDOR_FLR_6 | 12030340.02 | 0.00 | 12030340.02 | 391453.71 | 12421793.73 | 3961413.96 | 0.00 | 0.00 | 8760.00 | 0.00 |
Total Facility | 0.45E+10 | 12159826.70 | 0.45E+10 | 18434047.20 | 0.46E+10 | 0.43E+10 | 6839.89 | 7989.81 | 8760.00 | 8760.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
BASEMENT | 1.2701 | 0.0000 | 1.2701 | 0.0000 | 1.2701 | 0.8545 | 2.73 | 2.19 | 8755.08 |
RETAIL_1_FLR_1 | 0.1933 | 0.0000 | 0.1933 | 0.0100 | 0.2033 | 0.0792 | 0.00 | 0.00 | 8760.00 |
RETAIL_2_FLR_1 | 0.1187 | 0.0000 | 0.1187 | 0.0039 | 0.1226 | 0.0917 | 78.13 | 16.54 | 8665.33 |
MECH_FLR_1 | 0.1142 | 0.0000 | 0.1142 | 0.0091 | 0.1233 | 0.0000 | 0.00 | 0.00 | 8760.00 |
STORAGE_FLR_1 | 0.0551 | 0.0000 | 0.0551 | 0.0053 | 0.0603 | 0.0578 | 5416.36 | 447.81 | 2895.83 |
LAUNDRY_FLR_1 | 1.8156 | 0.0000 | 1.8156 | 0.0124 | 1.8281 | 0.0000 | 0.00 | 0.00 | 8760.00 |
CAFE_FLR_1 | 0.7849 | 0.0000 | 0.7849 | 0.0221 | 0.8069 | 0.6764 | 740.36 | 202.72 | 7816.92 |
LOBBY_FLR_1 | 2.4004 | 0.0000 | 2.4004 | 0.0631 | 2.4635 | 1.8940 | 85.71 | 28.88 | 8645.41 |
ROOM_1_FLR_3 | 0.0617 | 0.0021 | 0.0639 | 0.0058 | 0.0697 | 0.0617 | 0.00 | 7864.33 | 895.67 |
ROOM_2_FLR_3 | 0.0617 | 0.0021 | 0.0638 | 0.0058 | 0.0696 | 0.0617 | 0.00 | 7864.33 | 895.67 |
ROOM_4_MULT19_FLR_3 | 0.8373 | 0.0020 | 0.8393 | 0.0016 | 0.8410 | 0.8373 | 0.00 | 7891.35 | 868.65 |
ROOM_5_FLR_3 | 0.0617 | 0.0021 | 0.0639 | 0.0058 | 0.0697 | 0.0617 | 0.00 | 7864.33 | 895.67 |
ROOM_6_FLR_3 | 0.0617 | 0.0021 | 0.0638 | 0.0058 | 0.0696 | 0.0617 | 0.00 | 7864.33 | 895.67 |
CORRIDOR_FLR_3 | 0.7336 | 0.0000 | 0.7336 | 0.0070 | 0.7406 | 0.4748 | 1.44 | 0.92 | 8757.65 |
ROOM_1_FLR_6 | 0.0154 | 0.0026 | 0.0180 | 0.0058 | 0.0238 | 0.0154 | 0.00 | 7861.17 | 898.83 |
ROOM_2_FLR_6 | 0.0154 | 0.0025 | 0.0179 | 0.0058 | 0.0237 | 0.0154 | 0.00 | 7861.17 | 898.83 |
ROOM_3_MULT9_FLR_6 | 0.0992 | 0.0026 | 0.1017 | 0.0030 | 0.1047 | 0.0992 | 0.00 | 7861.36 | 898.64 |
BANQUET_FLR_6 | 1.2361 | 0.0000 | 1.2361 | 0.0142 | 1.2503 | 1.1878 | 4799.61 | 342.25 | 3618.14 |
DINING_FLR_6 | 1.3295 | 0.0000 | 1.3295 | 0.0142 | 1.3437 | 1.1878 | 2740.94 | 236.74 | 5782.33 |
KITCHEN_FLR_6 | 1.7218 | 0.0000 | 1.7218 | 0.0127 | 1.7345 | 0.3674 | 0.00 | 0.00 | 8760.00 |
CORRIDOR_FLR_6 | 0.3815 | 0.0000 | 0.3815 | 0.0124 | 0.3939 | 0.1256 | 0.00 | 0.00 | 8760.00 |
Total Facility | 79.9012 | 0.2170 | 80.1183 | 0.4615 | 80.5798 | 73.9670 | 6839.89 | 7989.81 | 8760.00 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
VAV WITH REHEAT | 0.56E+09 | 0.00 | 0.56E+09 | 0.22E+09 | 0.00 | 0.00 | 8760.00 | 0.00 |
FLR_3_DOAS | 93713071.71 | 638741.74 | 94351813.45 | 64690340.46 | 0.00 | 0.00 | 8760.00 | 0.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
VAV WITH REHEAT | 17.6102 | 0.0000 | 17.6102 | 6.9969 | 0.00 | 0.00 | 8760.00 |
FLR_3_DOAS | 2.9716 | 0.0203 | 2.9919 | 2.0513 | 0.00 | 0.00 | 8760.00 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
VAV WITH REHEAT | 0.00 | 6116.93 | 2643.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FLR_3_DOAS | 0.00 | 7732.59 | 1027.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
VAV WITH REHEAT | 0.0000 | 16.8958 | 19.2700 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
FLR_3_DOAS | 0.0000 | 2.9718 | 2.9728 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Surfaces by ClassTotal | Outdoors | |
Wall | 119 | 44 |
Floor | 25 | 0 |
Roof | 33 | 11 |
Internal Mass | 22 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 30 | 30 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 22 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1318 |
Defaulted Fields | 1181 |
Fields with Defaults | 4005 |
Autosized Fields | 350 |
Autosizable Fields | 402 |
Autocalculated Fields | 280 |
Autocalculatable Fields | 539 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
Electricity:Building | 2518.65 | 32537.67 | 20-MAY-05:00 | 151906.32 | 02-JAN-20:10 |
Electricity:Zone:BASEMENT | 323.72 | 3705.45 | 02-JAN-02:10 | 24299.15 | 02-JAN-20:10 |
Electricity:SpaceType:GENERAL | 2511.55 | 32396.52 | 20-MAY-05:00 | 151664.99 | 02-JAN-20:10 |
InteriorLights:Electricity | 766.54 | 6704.72 | 20-MAY-05:00 | 62892.57 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BASEMENT | 173.46 | 1576.23 | 02-JAN-02:10 | 14185.34 | 02-JAN-20:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 766.54 | 6704.72 | 20-MAY-05:00 | 62892.57 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity | 766.54 | 6704.72 | 20-MAY-05:00 | 62892.57 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:BASEMENT | 173.46 | 1576.23 | 02-JAN-02:10 | 14185.34 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 766.54 | 6704.72 | 20-MAY-05:00 | 62892.57 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_1_FLR_1 | 18.80 | 222.61 | 02-JAN-02:10 | 1390.02 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 | 8.61 | 78.27 | 02-JAN-02:10 | 704.41 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 | 8.61 | 78.27 | 02-JAN-02:10 | 704.41 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_2_FLR_1 | 21.77 | 257.78 | 02-JAN-02:10 | 1609.65 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 | 9.97 | 90.64 | 02-JAN-02:10 | 815.72 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 | 9.97 | 90.64 | 02-JAN-02:10 | 815.72 | 02-JAN-20:10 |
Electricity:Zone:MECH_FLR_1 | 29.11 | 327.88 | 02-JAN-02:10 | 2199.84 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:MECH_FLR_1 | 16.64 | 151.16 | 02-JAN-02:10 | 1360.40 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:MECH_FLR_1 | 16.64 | 151.16 | 02-JAN-02:10 | 1360.40 | 02-JAN-20:10 |
Electricity:Zone:STORAGE_FLR_1 | 6.38 | 76.28 | 02-JAN-02:10 | 469.87 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:STORAGE_FLR_1 | 2.78 | 25.30 | 02-JAN-02:10 | 227.72 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:STORAGE_FLR_1 | 2.78 | 25.30 | 02-JAN-02:10 | 227.72 | 02-JAN-20:10 |
Electricity:Zone:LAUNDRY_FLR_1 | 72.30 | 1002.39 | 02-JAN-02:10 | 4930.01 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 | 4.37 | 39.69 | 02-JAN-02:10 | 357.21 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 | 4.37 | 39.69 | 02-JAN-02:10 | 357.21 | 02-JAN-20:10 |
Electricity:Zone:CAFE_FLR_1 | 32.27 | 322.63 | 20-MAY-05:00 | 2727.18 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CAFE_FLR_1 | 17.93 | 119.42 | 20-MAY-05:00 | 1761.91 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CAFE_FLR_1 | 17.93 | 119.42 | 20-MAY-05:00 | 1761.91 | 02-JAN-20:10 |
Electricity:Zone:LOBBY_FLR_1 | 270.86 | 3198.76 | 20-MAY-05:00 | 20294.39 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LOBBY_FLR_1 | 121.86 | 1087.35 | 20-MAY-05:00 | 10265.18 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:LOBBY_FLR_1 | 121.86 | 1087.35 | 20-MAY-05:00 | 10265.18 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_3 | 18.66 | 264.62 | 01-JAN-02:10 | 1227.54 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_3 | 6.37 | 53.90 | 01-JAN-02:10 | 490.02 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_3 | 6.37 | 53.90 | 01-JAN-02:10 | 490.02 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_3 | 18.66 | 264.59 | 01-JAN-02:10 | 1227.39 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_3 | 6.37 | 53.89 | 01-JAN-02:10 | 489.96 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_3 | 6.37 | 53.89 | 01-JAN-02:10 | 489.96 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT19_FLR_3 | 304.77 | 4565.05 | 01-JAN-02:10 | 20923.25 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 76.02 | 643.59 | 01-JAN-02:10 | 5851.22 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 76.02 | 643.59 | 01-JAN-02:10 | 5851.22 | 01-JAN-19:10 |
Electricity:Zone:ROOM_4_MULT19_FLR_3 | 304.86 | 4566.30 | 01-JAN-02:10 | 20928.98 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 76.04 | 643.77 | 01-JAN-02:10 | 5852.82 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 76.04 | 643.77 | 01-JAN-02:10 | 5852.82 | 01-JAN-19:10 |
Electricity:Zone:ROOM_5_FLR_3 | 18.66 | 264.62 | 01-JAN-02:10 | 1227.54 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_5_FLR_3 | 6.37 | 53.90 | 01-JAN-02:10 | 490.02 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_5_FLR_3 | 6.37 | 53.90 | 01-JAN-02:10 | 490.02 | 01-JAN-19:10 |
Electricity:Zone:ROOM_6_FLR_3 | 18.66 | 264.59 | 01-JAN-02:10 | 1227.39 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_6_FLR_3 | 6.37 | 53.89 | 01-JAN-02:10 | 489.96 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_6_FLR_3 | 6.37 | 53.89 | 01-JAN-02:10 | 489.96 | 01-JAN-19:10 |
Electricity:Zone:CORRIDOR_FLR_3 | 109.60 | 995.90 | 02-JAN-02:10 | 8963.13 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 | 109.60 | 995.90 | 02-JAN-02:10 | 8963.13 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 | 109.60 | 995.90 | 02-JAN-02:10 | 8963.13 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_6 | 4.66 | 66.15 | 01-JAN-02:10 | 306.88 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_6 | 1.59 | 13.47 | 01-JAN-02:10 | 122.50 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_6 | 1.59 | 13.47 | 01-JAN-02:10 | 122.50 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_6 | 4.66 | 66.15 | 01-JAN-02:10 | 306.85 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_6 | 1.59 | 13.47 | 01-JAN-02:10 | 122.49 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_6 | 1.59 | 13.47 | 01-JAN-02:10 | 122.49 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT9_FLR_6 | 36.10 | 540.75 | 01-JAN-02:10 | 2478.43 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 9.00 | 76.24 | 01-JAN-02:10 | 693.10 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 9.00 | 76.24 | 01-JAN-02:10 | 693.10 | 01-JAN-19:10 |
Electricity:Zone:BANQUET_FLR_6 | 210.49 | 2524.33 | 20-MAY-05:00 | 9841.96 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BANQUET_FLR_6 | 34.64 | 275.03 | 20-MAY-05:00 | 3094.06 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:BANQUET_FLR_6 | 34.64 | 275.03 | 20-MAY-05:00 | 3094.06 | 02-JAN-20:10 |
Electricity:Zone:DINING_FLR_6 | 210.49 | 2524.33 | 20-MAY-05:00 | 9841.96 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:DINING_FLR_6 | 34.64 | 275.03 | 20-MAY-05:00 | 3094.06 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:DINING_FLR_6 | 34.64 | 275.03 | 20-MAY-05:00 | 3094.06 | 02-JAN-20:10 |
Electricity:Zone:KITCHEN_FLR_6 | 454.16 | 6253.02 | 02-JAN-02:10 | 18944.06 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:KITCHEN_FLR_6 | 13.33 | 121.09 | 02-JAN-02:10 | 1089.83 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:KITCHEN_FLR_6 | 13.33 | 121.09 | 02-JAN-02:10 | 1089.83 | 02-JAN-20:10 |
Electricity:Zone:CORRIDOR_FLR_6 | 29.00 | 263.50 | 02-JAN-02:10 | 2371.52 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 | 29.00 | 263.50 | 02-JAN-02:10 | 2371.52 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 | 29.00 | 263.50 | 02-JAN-02:10 | 2371.52 | 02-JAN-20:10 |
InteriorEquipment:Electricity | 1745.01 | 25691.80 | 02-JAN-02:10 | 89475.41 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:BASEMENT | 150.26 | 2129.22 | 02-JAN-02:10 | 10113.80 | 02-JAN-20:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 1745.01 | 25691.80 | 02-JAN-02:10 | 89475.41 | 02-JAN-07:10 |
MiscPlug:InteriorEquipment:Electricity | 959.56 | 15202.41 | 02-JAN-02:10 | 59492.27 | 02-JAN-07:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:BASEMENT | 150.26 | 2129.22 | 02-JAN-02:10 | 10113.80 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 959.56 | 15202.41 | 02-JAN-02:10 | 59492.27 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 | 10.19 | 144.34 | 02-JAN-02:10 | 685.60 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 | 10.19 | 144.34 | 02-JAN-02:10 | 685.60 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 | 11.79 | 167.14 | 02-JAN-02:10 | 793.93 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 | 11.79 | 167.14 | 02-JAN-02:10 | 793.93 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:MECH_FLR_1 | 12.47 | 176.73 | 02-JAN-02:10 | 839.45 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:MECH_FLR_1 | 12.47 | 176.73 | 02-JAN-02:10 | 839.45 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 | 3.60 | 50.98 | 02-JAN-02:10 | 242.16 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 | 3.60 | 50.98 | 02-JAN-02:10 | 242.16 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 | 67.94 | 962.69 | 02-JAN-02:10 | 4572.80 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 | 67.94 | 962.69 | 02-JAN-02:10 | 4572.80 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:CAFE_FLR_1 | 14.34 | 203.22 | 02-JAN-02:10 | 965.27 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CAFE_FLR_1 | 14.34 | 203.22 | 02-JAN-02:10 | 965.27 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 | 149.00 | 2111.41 | 02-JAN-02:10 | 10029.21 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 | 149.00 | 2111.41 | 02-JAN-02:10 | 10029.21 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 228.75 | 3921.46 | 01-JAN-00:10 | 17646.57 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 228.75 | 3921.46 | 01-JAN-00:10 | 17646.57 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 228.82 | 3922.53 | 01-JAN-00:10 | 17651.40 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 228.82 | 3922.53 | 01-JAN-00:10 | 17651.40 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 | 3.07 | 52.68 | 01-JAN-00:10 | 237.06 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 | 3.07 | 52.68 | 01-JAN-00:10 | 237.06 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 | 3.07 | 52.67 | 01-JAN-00:10 | 237.03 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 | 3.07 | 52.67 | 01-JAN-00:10 | 237.03 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 27.10 | 464.51 | 01-JAN-00:10 | 2090.30 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 27.10 | 464.51 | 01-JAN-00:10 | 2090.30 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity | 762.04 | 9746.88 | 01-JAN-00:10 | 29240.64 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:SpaceType:GENERAL | 762.04 | 9746.88 | 01-JAN-00:10 | 29240.64 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:DINING_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:DINING_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 433.74 | 5990.78 | 01-JAN-00:10 | 16487.34 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 410.33 | 5248.28 | 01-JAN-00:10 | 15744.84 | 01-JAN-07:10 |
ReachInFreezer:InteriorEquipment:Electricity | 14.43 | 457.50 | 01-JAN-00:10 | 457.50 | 01-JAN-00:10 |
ReachInFreezer:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 14.43 | 457.50 | 01-JAN-00:10 | 457.50 | 01-JAN-00:10 |
ReachInFreezer:InteriorEquipment:Electricity:SpaceType:GENERAL | 14.43 | 457.50 | 01-JAN-00:10 | 457.50 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity | 8.99 | 285.00 | 01-JAN-00:10 | 285.00 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 8.99 | 285.00 | 01-JAN-00:10 | 285.00 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity:SpaceType:GENERAL | 8.99 | 285.00 | 01-JAN-00:10 | 285.00 | 01-JAN-00:10 |
Refrigeration:Electricity | 62.02 | 1114.64 | 11-FEB-23:30 | 3479.68 | 31-OCT-06:20 |
Refrigeration:Electricity:Zone:KITCHEN_FLR_6 | 7.09 | 88.82 | 02-JAN-11:30 | 2093.44 | 01-JAN-11:10 |
General:Refrigeration:Electricity | 7.09 | 88.82 | 02-JAN-11:30 | 2093.44 | 01-JAN-11:10 |
General:Refrigeration:Electricity:Zone:KITCHEN_FLR_6 | 7.09 | 88.82 | 02-JAN-11:30 | 2093.44 | 01-JAN-11:10 |
Electricity:Plant | 1464.15 | 2579.68 | 12-APR-00:30 | 214576.24 | 16-AUG-15:20 |
LowTempRefrigeration:Refrigeration:Electricity | 20.46 | 0.00 | 01-JAN-11:10 | 2049.73 | 31-OCT-06:20 |
MedTempRefrigeration:Refrigeration:Electricity | 34.47 | 934.38 | 06-FEB-04:10 | 1245.48 | 12-MAR-09:00 |
Fans:Electricity | 571.72 | 12846.55 | 05-NOV-03:00 | 44313.79 | 19-JAN-21:40 |
Fans:Electricity:Zone:ROOM_1_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_5_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_5_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_6_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_6_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_1_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Electricity:HVAC | 826.44 | 14278.91 | 22-OCT-01:40 | 51046.35 | 07-SEP-21:10 |
ExteriorEquipment:Electricity | 651.48 | 9618.58 | 02-JAN-02:20 | 39726.11 | 02-JAN-07:20 |
Transformer:ExteriorEquipment:Electricity | 32.45 | 553.73 | 10-JUN-05:00 | 1868.65 | 23-MAR-20:10 |
ElectricityPurchased:Facility | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
ElectricityPurchased:Plant | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
Cogeneration:ElectricityPurchased | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
General:Cogeneration:ElectricityPurchased | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
ElectricityNet:Plant | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
Cogeneration:ElectricityNet | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
General:Cogeneration:ElectricityNet | 5670.82 | 75716.98 | 06-APR-02:40 | 454905.91 | 04-AUG-19:10 |
General:Fans:Electricity | 571.72 | 12846.55 | 05-NOV-03:00 | 44313.79 | 19-JAN-21:40 |
ExteriorLights:Electricity | 242.55 | 0.00 | 01-JAN-07:30 | 15448.40 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 242.55 | 0.00 | 01-JAN-07:30 | 15448.40 | 01-JAN-00:10 |
ElevatorLift:ExteriorEquipment:Electricity | 616.11 | 9046.01 | 01-JAN-00:10 | 37691.69 | 01-JAN-07:10 |
ElevatorLightsFan:ExteriorEquipment:Electricity | 2.91 | 18.80 | 01-JAN-00:10 | 188.00 | 01-JAN-07:10 |
HeatRecovery:Electricity | 222.27 | 0.00 | 02-MAR-15:40 | 9938.94 | 03-JAN-18:20 |
General:HeatRecovery:Electricity | 222.27 | 0.00 | 02-MAR-15:40 | 9938.94 | 03-JAN-18:20 |
WaterSystems:Electricity | 90.75 | 1086.57 | 13-SEP-00:30 | 4738.56 | 10-NOV-19:10 |
Water Heater:WaterSystems:Electricity | 90.75 | 1086.57 | 13-SEP-00:30 | 4738.56 | 10-NOV-19:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 1189.20 | 0.00 | 01-JAN-00:10 | 203778.65 | 16-AUG-15:20 |
General:Cooling:Electricity | 1189.20 | 0.00 | 01-JAN-00:10 | 203778.65 | 16-AUG-15:20 |
Pumps:Electricity | 129.27 | 47.91 | 10-MAY-07:10 | 7648.61 | 24-JUN-18:10 |
General:Pumps:Electricity | 129.27 | 47.91 | 10-MAY-07:10 | 7648.61 | 24-JUN-18:10 |
WIRED_LTG_ELECTRICITY | 26.98 | 0.00 | 01-JAN-00:10 | 2213.82 | 02-JAN-20:20 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 5648.58 | 29270.80 | 07-APR-01:20 | 560006.54 | 05-FEB-19:10 |
NaturalGas:Building | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
NaturalGas:SpaceType:GENERAL | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
InteriorEquipment:NaturalGas | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
InteriorEquipment:NaturalGas:SpaceType:GENERAL | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
Laundry:InteriorEquipment:NaturalGas | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Laundry:InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Laundry:InteriorEquipment:NaturalGas:SpaceType:GENERAL | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas:SpaceType:GENERAL | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
NaturalGas:Plant | 3859.75 | 15908.90 | 20-JUN-10:10 | 494940.87 | 05-FEB-24:00 |
WaterSystems:NaturalGas | 3097.94 | 15908.90 | 01-JAN-16:10 | 297324.00 | 03-MAR-21:20 |
Water Heater:WaterSystems:NaturalGas | 3097.94 | 15908.90 | 01-JAN-16:10 | 297324.00 | 03-MAR-21:20 |
Heating:NaturalGas | 761.81 | 0.00 | 02-MAR-15:30 | 259652.49 | 06-FEB-09:10 |
Boiler:Heating:NaturalGas | 761.81 | 0.00 | 02-MAR-15:30 | 259652.49 | 06-FEB-09:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopCoolingDemand:Facility | 3880.89 | -61.72 | 12-MAR-00:20 | 682996.29 | 24-JUN-18:10 |
PlantLoopCoolingDemand:HVAC | 3880.89 | -61.72 | 12-MAR-00:20 | 682996.29 | 24-JUN-18:10 |
CoolingCoils:PlantLoopCoolingDemand | 3880.89 | -61.72 | 12-MAR-00:20 | 682996.29 | 24-JUN-18:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
Water:Plant | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
WaterSystems:Water | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
Water Heater:WaterSystems:Water | 5742.51 | 0.00 | 04-MAR-01:10 | 0.00 | 02-JAN-19:10 |
MainsWater:Facility | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
MainsWater:Plant | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
WaterSystems:MainsWater | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 12-JAN-21:20 |
Water Heater:WaterSystems:MainsWater | 5742.51 | 0.00 | 04-MAR-01:10 | 0.00 | 02-JAN-19:10 |
WaterUse:WaterSystems:Water | 4114.69 | 0.00 | 02-JAN-01:10 | 0.00 | 18-JAN-08:00 |
WaterUse:WaterSystems:MainsWater | 4114.69 | 0.00 | 02-JAN-01:10 | 0.00 | 18-JAN-08:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 23790.21 | 142913.07 | 30-APR-14:10 | 2771323.15 | 16-AUG-15:20 |
EnergyTransfer:Building | 5346.77 | 56325.73 | 08-DEC-15:40 | 353778.18 | 19-JUN-18:20 |
EnergyTransfer:Zone:KITCHEN_FLR_6 | 717.29 | 8692.40 | 14-MAY-01:20 | 36697.45 | 09-JUL-10:40 |
Refrigeration:EnergyTransfer | 183.85 | 3986.66 | 06-FEB-04:00 | 10705.13 | 31-OCT-06:20 |
Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 | 91.92 | 1993.33 | 06-FEB-04:00 | 5352.56 | 31-OCT-06:20 |
General:Refrigeration:EnergyTransfer | 91.92 | 1993.33 | 06-FEB-04:00 | 5352.56 | 31-OCT-06:20 |
General:Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 | 91.92 | 1993.33 | 06-FEB-04:00 | 5352.56 | 31-OCT-06:20 |
EnergyTransfer:Plant | 10537.64 | 14434.07 | 08-OCT-00:50 | 1580134.43 | 24-JUN-18:10 |
LowTempRefrigeration:Refrigeration:EnergyTransfer | 21.62 | 0.00 | 01-JAN-11:10 | 2686.44 | 01-JAN-11:40 |
MedTempRefrigeration:Refrigeration:EnergyTransfer | 70.30 | 1753.13 | 06-FEB-04:10 | 2686.44 | 12-MAR-09:00 |
EnergyTransfer:Zone:BASEMENT | 426.88 | 1998.96 | 12-MAR-08:50 | 25176.57 | 17-NOV-20:40 |
Heating:EnergyTransfer | 186.17 | 0.00 | 03-JAN-18:30 | 112923.02 | 14-JAN-16:10 |
Heating:EnergyTransfer:Zone:BASEMENT | 0.04 | 0.00 | 01-JAN-00:10 | 947.95 | 27-OCT-22:30 |
General:Heating:EnergyTransfer | 186.17 | 0.00 | 03-JAN-18:30 | 112923.02 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:BASEMENT | 0.04 | 0.00 | 01-JAN-00:10 | 947.95 | 27-OCT-22:30 |
Cooling:EnergyTransfer | 5068.67 | 49485.58 | 08-DEC-15:40 | 350169.15 | 19-JUN-18:20 |
Cooling:EnergyTransfer:Zone:BASEMENT | 426.84 | 1850.75 | 12-MAR-08:50 | 25176.57 | 17-NOV-20:40 |
General:Cooling:EnergyTransfer | 5068.67 | 49485.58 | 08-DEC-15:40 | 350169.15 | 19-JUN-18:20 |
General:Cooling:EnergyTransfer:Zone:BASEMENT | 426.84 | 1850.75 | 12-MAR-08:50 | 25176.57 | 17-NOV-20:40 |
EnergyTransfer:Zone:RETAIL_1_FLR_1 | 43.80 | 0.11 | 21-FEB-17:20 | 4470.45 | 04-OCT-12:10 |
Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 1.27 | 0.00 | 01-JAN-08:30 | 1433.94 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 1.27 | 0.00 | 01-JAN-08:30 | 1433.94 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 42.53 | 0.00 | 01-JAN-00:10 | 4470.45 | 04-OCT-12:10 |
General:Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 42.53 | 0.00 | 01-JAN-00:10 | 4470.45 | 04-OCT-12:10 |
EnergyTransfer:Zone:RETAIL_2_FLR_1 | 35.99 | 168.62 | 31-OCT-06:10 | 2272.90 | 04-AUG-21:00 |
Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 180.98 | 25-DEC-05:50 |
General:Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 180.98 | 25-DEC-05:50 |
Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 35.98 | 87.73 | 08-DEC-15:40 | 2272.90 | 04-AUG-21:00 |
General:Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 35.98 | 87.73 | 08-DEC-15:40 | 2272.90 | 04-AUG-21:00 |
EnergyTransfer:Zone:MECH_FLR_1 | 28.63 | 0.05 | 01-FEB-03:10 | 2247.29 | 17-AUG-20:00 |
Heating:EnergyTransfer:Zone:MECH_FLR_1 | 0.29 | 0.00 | 01-JAN-19:10 | 616.01 | 02-JAN-04:50 |
General:Heating:EnergyTransfer:Zone:MECH_FLR_1 | 0.29 | 0.00 | 01-JAN-19:10 | 616.01 | 02-JAN-04:50 |
Cooling:EnergyTransfer:Zone:MECH_FLR_1 | 28.34 | 0.00 | 01-JAN-00:10 | 2247.29 | 17-AUG-20:00 |
General:Cooling:EnergyTransfer:Zone:MECH_FLR_1 | 28.34 | 0.00 | 01-JAN-00:10 | 2247.29 | 17-AUG-20:00 |
EnergyTransfer:Zone:STORAGE_FLR_1 | 12.81 | 0.04 | 26-JAN-17:00 | 874.09 | 04-AUG-21:00 |
Heating:EnergyTransfer:Zone:STORAGE_FLR_1 | 0.52 | 0.00 | 03-JAN-18:30 | 478.83 | 02-JAN-05:00 |
General:Heating:EnergyTransfer:Zone:STORAGE_FLR_1 | 0.52 | 0.00 | 03-JAN-18:30 | 478.83 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 | 12.29 | 0.00 | 01-JAN-00:10 | 874.09 | 04-AUG-21:00 |
General:Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 | 12.29 | 0.00 | 01-JAN-00:10 | 874.09 | 04-AUG-21:00 |
EnergyTransfer:Zone:LAUNDRY_FLR_1 | 592.96 | 5745.10 | 01-MAY-02:30 | 39016.04 | 04-AUG-20:00 |
Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 652.85 | 27-MAR-03:50 |
General:Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 652.85 | 27-MAR-03:50 |
Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 592.95 | 5745.10 | 01-MAY-02:30 | 39016.04 | 04-AUG-20:00 |
General:Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 592.95 | 5745.10 | 01-MAY-02:30 | 39016.04 | 04-AUG-20:00 |
EnergyTransfer:Zone:CAFE_FLR_1 | 239.49 | 17.60 | 14-JAN-13:50 | 15303.21 | 30-SEP-12:40 |
Heating:EnergyTransfer:Zone:CAFE_FLR_1 | 0.06 | 0.00 | 01-JAN-00:10 | 913.21 | 15-JAN-11:30 |
General:Heating:EnergyTransfer:Zone:CAFE_FLR_1 | 0.06 | 0.00 | 01-JAN-00:10 | 913.21 | 15-JAN-11:30 |
Cooling:EnergyTransfer:Zone:CAFE_FLR_1 | 239.43 | 0.00 | 08-JAN-13:50 | 15303.21 | 30-SEP-12:40 |
General:Cooling:EnergyTransfer:Zone:CAFE_FLR_1 | 239.43 | 0.00 | 08-JAN-13:50 | 15303.21 | 30-SEP-12:40 |
EnergyTransfer:Zone:LOBBY_FLR_1 | 780.18 | 3361.23 | 12-MAR-08:50 | 43844.34 | 04-AUG-21:10 |
Heating:EnergyTransfer:Zone:LOBBY_FLR_1 | 0.08 | 0.00 | 01-JAN-00:10 | 2496.36 | 15-JAN-11:30 |
General:Heating:EnergyTransfer:Zone:LOBBY_FLR_1 | 0.08 | 0.00 | 01-JAN-00:10 | 2496.36 | 15-JAN-11:30 |
Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 | 780.10 | 2861.76 | 08-DEC-15:40 | 43844.34 | 04-AUG-21:10 |
General:Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 | 780.10 | 2861.76 | 08-DEC-15:40 | 43844.34 | 04-AUG-21:10 |
EnergyTransfer:Zone:ROOM_1_FLR_3 | 73.14 | 0.15 | 11-APR-05:00 | 12724.60 | 15-AUG-15:10 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 | 18.42 | 0.00 | 01-JAN-08:10 | 7101.11 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 | 18.42 | 0.00 | 01-JAN-08:10 | 7101.11 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 | 54.72 | 0.00 | 01-JAN-00:10 | 12724.60 | 15-AUG-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 | 54.72 | 0.00 | 01-JAN-00:10 | 12724.60 | 15-AUG-15:10 |
EnergyTransfer:Zone:ROOM_2_FLR_3 | 70.26 | 0.06 | 12-APR-00:20 | 12054.01 | 02-AUG-15:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 | 23.29 | 0.00 | 01-JAN-08:10 | 7210.48 | 06-FEB-09:10 |
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 | 23.29 | 0.00 | 01-JAN-08:10 | 7210.48 | 06-FEB-09:10 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 | 46.97 | 0.00 | 01-JAN-00:10 | 12054.01 | 02-AUG-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 | 46.97 | 0.00 | 01-JAN-00:10 | 12054.01 | 02-AUG-15:10 |
EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 414.60 | 0.71 | 30-DEC-07:50 | 60539.24 | 04-OCT-12:10 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 10.85 | 0.00 | 01-JAN-08:10 | 19243.50 | 02-JAN-05:00 |
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 10.85 | 0.00 | 01-JAN-08:10 | 19243.50 | 02-JAN-05:00 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 403.75 | 0.00 | 01-JAN-00:10 | 60539.24 | 04-OCT-12:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 403.75 | 0.00 | 01-JAN-00:10 | 60539.24 | 04-OCT-12:10 |
EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 432.68 | 0.47 | 01-APR-23:30 | 67798.37 | 10-JUL-15:20 |
Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 56.45 | 0.00 | 01-JAN-08:10 | 46333.94 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 56.45 | 0.00 | 01-JAN-08:10 | 46333.94 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 376.23 | 0.00 | 01-JAN-00:10 | 67798.37 | 10-JUL-15:20 |
General:Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 376.23 | 0.00 | 01-JAN-00:10 | 67798.37 | 10-JUL-15:20 |
EnergyTransfer:Zone:ROOM_5_FLR_3 | 72.54 | 0.14 | 01-JAN-10:00 | 11459.10 | 22-AUG-08:10 |
Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 | 18.21 | 0.00 | 01-JAN-08:10 | 7150.83 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 | 18.21 | 0.00 | 01-JAN-08:10 | 7150.83 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 | 54.33 | 0.00 | 01-JAN-00:10 | 11459.10 | 22-AUG-08:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 | 54.33 | 0.00 | 01-JAN-00:10 | 11459.10 | 22-AUG-08:10 |
EnergyTransfer:Zone:ROOM_6_FLR_3 | 68.88 | 0.16 | 19-MAR-13:20 | 11230.77 | 14-JUL-08:10 |
Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 | 22.78 | 0.00 | 01-JAN-08:10 | 7211.81 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 | 22.78 | 0.00 | 01-JAN-08:10 | 7211.81 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 | 46.10 | 0.00 | 01-JAN-00:10 | 11230.77 | 14-JUL-08:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 | 46.10 | 0.00 | 01-JAN-00:10 | 11230.77 | 14-JUL-08:10 |
EnergyTransfer:Zone:CORRIDOR_FLR_3 | 189.03 | 0.25 | 04-FEB-09:50 | 12482.13 | 18-AUG-18:20 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 0.78 | 0.00 | 01-JAN-00:30 | 3266.21 | 14-JAN-16:30 |
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 0.78 | 0.00 | 01-JAN-00:30 | 3266.21 | 14-JAN-16:30 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 188.25 | 0.00 | 01-JAN-00:10 | 12482.13 | 18-AUG-18:20 |
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 188.25 | 0.00 | 01-JAN-00:10 | 12482.13 | 18-AUG-18:20 |
EnergyTransfer:Zone:ROOM_1_FLR_6 | 20.30 | 0.04 | 23-FEB-14:00 | 3363.16 | 18-AUG-15:10 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 | 6.92 | 0.00 | 01-JAN-11:10 | 2254.10 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 | 6.92 | 0.00 | 01-JAN-11:10 | 2254.10 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 | 13.38 | 0.00 | 01-JAN-00:10 | 3363.16 | 18-AUG-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 | 13.38 | 0.00 | 01-JAN-00:10 | 3363.16 | 18-AUG-15:10 |
EnergyTransfer:Zone:ROOM_2_FLR_6 | 19.90 | 0.10 | 12-MAR-14:10 | 3207.31 | 13-JUL-15:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 | 8.51 | 0.00 | 03-JAN-08:10 | 2280.20 | 14-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 | 8.51 | 0.00 | 03-JAN-08:10 | 2280.20 | 14-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 | 11.40 | 0.00 | 01-JAN-00:10 | 3207.31 | 13-JUL-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 | 11.40 | 0.00 | 01-JAN-00:10 | 3207.31 | 13-JUL-15:10 |
EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 102.94 | 0.07 | 20-FEB-00:10 | 15619.66 | 22-AUG-15:10 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 16.67 | 0.00 | 01-JAN-08:10 | 10685.32 | 14-JAN-16:20 |
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 16.67 | 0.00 | 01-JAN-08:10 | 10685.32 | 14-JAN-16:20 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 86.27 | 0.00 | 01-JAN-00:10 | 15619.66 | 22-AUG-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 86.27 | 0.00 | 01-JAN-00:10 | 15619.66 | 22-AUG-15:10 |
EnergyTransfer:Zone:BANQUET_FLR_6 | 435.73 | 2247.21 | 08-DEC-15:40 | 23825.34 | 04-AUG-21:20 |
Heating:EnergyTransfer:Zone:BANQUET_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 118.05 | 31-OCT-06:20 |
General:Heating:EnergyTransfer:Zone:BANQUET_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 118.05 | 31-OCT-06:20 |
Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 | 435.73 | 2247.21 | 08-DEC-15:40 | 23825.34 | 04-AUG-21:20 |
General:Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 | 435.73 | 2247.21 | 08-DEC-15:40 | 23825.34 | 04-AUG-21:20 |
EnergyTransfer:Zone:DINING_FLR_6 | 474.38 | 2811.63 | 08-DEC-15:40 | 24997.59 | 04-AUG-21:20 |
Heating:EnergyTransfer:Zone:DINING_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 80.77 | 31-OCT-06:20 |
General:Heating:EnergyTransfer:Zone:DINING_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 80.77 | 31-OCT-06:20 |
Cooling:EnergyTransfer:Zone:DINING_FLR_6 | 474.38 | 2811.63 | 08-DEC-15:40 | 24997.59 | 04-AUG-21:20 |
General:Cooling:EnergyTransfer:Zone:DINING_FLR_6 | 474.38 | 2811.63 | 08-DEC-15:40 | 24997.59 | 04-AUG-21:20 |
Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 37.44 | 18-OCT-01:50 |
General:Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 37.44 | 18-OCT-01:50 |
Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 | 625.36 | 6298.53 | 14-MAY-01:20 | 31608.25 | 13-AUG-10:50 |
General:Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 | 625.36 | 6298.53 | 14-MAY-01:20 | 31608.25 | 13-AUG-10:50 |
EnergyTransfer:Zone:CORRIDOR_FLR_6 | 94.36 | 0.09 | 18-MAR-05:30 | 7302.76 | 16-AUG-12:50 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 1.01 | 0.00 | 01-JAN-09:00 | 2521.16 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 1.01 | 0.00 | 01-JAN-09:00 | 2521.16 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 93.35 | 0.00 | 01-JAN-00:10 | 7302.76 | 16-AUG-12:50 |
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 93.35 | 0.00 | 01-JAN-00:10 | 7302.76 | 16-AUG-12:50 |
PlantLoopHeatingDemand:Facility | 1283.90 | 8505.09 | 11-AUG-02:00 | 256465.62 | 06-FEB-07:10 |
PlantLoopHeatingDemand:Plant | 742.72 | 8505.09 | 11-AUG-02:00 | 56503.94 | 06-FEB-07:10 |
WaterSystems:PlantLoopHeatingDemand | 742.72 | 8505.09 | 11-AUG-02:00 | 56503.94 | 06-FEB-07:10 |
General:WaterSystems:PlantLoopHeatingDemand | 742.72 | 8505.09 | 11-AUG-02:00 | 56503.94 | 06-FEB-07:10 |
EnergyTransfer:HVAC | 7905.80 | 15.12 | 20-MAY-07:40 | 898507.18 | 16-AUG-15:20 |
HeatingCoils:EnergyTransfer | 541.18 | 0.00 | 02-MAR-15:30 | 215528.89 | 14-JAN-16:10 |
PlantLoopHeatingDemand:HVAC | 541.18 | 0.00 | 02-MAR-15:30 | 215528.89 | 14-JAN-16:10 |
HeatingCoils:PlantLoopHeatingDemand | 541.18 | 0.00 | 02-MAR-15:30 | 215528.89 | 14-JAN-16:10 |
CoolingCoils:EnergyTransfer | 3880.89 | -61.72 | 12-MAR-00:20 | 682996.29 | 24-JUN-18:10 |
HeatRecoveryForHeating:EnergyTransfer | 2928.16 | 0.00 | 02-MAR-15:40 | 487649.56 | 06-FEB-03:00 |
HeatRecoveryForCooling:EnergyTransfer | 555.57 | 0.00 | 01-JAN-00:10 | 279121.09 | 08-JUL-12:00 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:EnergyTransfer | 742.72 | 8505.09 | 11-AUG-02:00 | 56503.94 | 06-FEB-07:10 |
WaterUse:WaterSystems:EnergyTransfer | 742.72 | 8505.09 | 11-AUG-02:00 | 56503.94 | 06-FEB-07:10 |
Boilers:EnergyTransfer | 535.18 | 0.00 | 02-MAR-15:30 | 211685.36 | 14-JAN-16:10 |
Chillers:EnergyTransfer | 3989.31 | 0.00 | 01-JAN-00:10 | 691369.08 | 24-JUN-18:10 |
HeatRejection:EnergyTransfer | 5178.51 | 0.00 | 01-JAN-00:10 | 861468.59 | 16-AUG-15:20 |
General:HeatRejection:EnergyTransfer | 5178.51 | 0.00 | 01-JAN-00:10 | 861468.59 | 16-AUG-15:20 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BASEMENT | 0.000 | 0.000 | 0.036 | -426.843 | 0.000 | 0.000 | 138.765 | 173.462 | 150.255 | 0.000 | 0.000 | 0.000 | 0.001 | 0.000 | 0.000 | 0.000 | 0.000 | -35.675 |
RETAIL_1_FLR_1 | 0.000 | 0.000 | 1.270 | -42.526 | 0.000 | 0.000 | 15.476 | 8.614 | 10.186 | 27.367 | 0.000 | 0.176 | 0.000 | 0.000 | -9.902 | 0.000 | -3.934 | -6.726 |
RETAIL_2_FLR_1 | 0.000 | 0.000 | 0.015 | -35.979 | 0.000 | 0.000 | 17.007 | 9.975 | 11.795 | 0.000 | 0.000 | 0.065 | 0.000 | 0.000 | 0.000 | 0.000 | -1.612 | -1.264 |
MECH_FLR_1 | 0.000 | 0.000 | 0.288 | -28.345 | 0.000 | 0.000 | 3.713 | 16.635 | 12.471 | 0.000 | 0.000 | 0.154 | 0.000 | 0.000 | 0.000 | 0.000 | -3.643 | -1.274 |
STORAGE_FLR_1 | 0.000 | 0.000 | 0.518 | -12.290 | 0.000 | 0.000 | 2.879 | 2.785 | 3.598 | 0.000 | 0.000 | 0.092 | 4.499 | 0.000 | 0.000 | 0.000 | -2.080 | -0.000 |
LAUNDRY_FLR_1 | 0.000 | 0.000 | 0.006 | -592.953 | 0.000 | 0.000 | 11.280 | 4.368 | 658.131 | 0.000 | 0.000 | 0.258 | 0.000 | 0.000 | 0.000 | 0.000 | -5.425 | -75.664 |
CAFE_FLR_1 | 0.000 | 0.000 | 0.062 | -239.430 | 0.000 | 0.000 | 191.991 | 17.926 | 14.341 | 76.014 | 0.000 | 0.356 | 0.000 | 0.000 | -29.754 | 0.000 | -9.338 | -22.168 |
LOBBY_FLR_1 | 0.000 | 0.000 | 0.085 | -780.105 | 0.000 | 0.000 | 556.659 | 121.863 | 148.998 | 100.574 | 0.000 | 1.018 | 0.000 | 0.000 | -40.439 | 0.000 | -27.443 | -81.210 |
ROOM_1_FLR_3 | 22.677 | -42.919 | 0.000 | -16.064 | 0.000 | 0.000 | 9.734 | 6.366 | 12.292 | 52.252 | 0.000 | 0.799 | 0.000 | 0.000 | -22.089 | 0.000 | -9.465 | -13.583 |
ROOM_2_FLR_3 | 28.033 | -35.944 | 0.000 | -15.765 | 0.000 | 0.000 | 9.761 | 6.366 | 12.291 | 37.455 | 0.000 | 0.797 | 0.000 | 0.000 | -22.683 | 0.000 | -9.326 | -10.985 |
ROOM_3_MULT19_FLR_3 | 18.190 | -170.187 | 0.000 | -240.910 | 0.000 | 0.000 | 0.000 | 76.021 | 228.754 | 329.047 | 0.000 | 2.334 | 0.001 | 0.000 | -123.543 | 0.000 | -70.083 | -49.622 |
ROOM_4_MULT19_FLR_3 | 102.227 | -208.728 | 0.000 | -213.265 | 0.000 | 0.000 | 185.550 | 76.042 | 228.817 | 103.770 | 0.000 | 6.543 | 0.000 | 0.000 | -126.987 | 0.000 | -56.978 | -96.992 |
ROOM_5_FLR_3 | 22.383 | -42.376 | 0.000 | -16.123 | 0.000 | 0.000 | 9.729 | 6.366 | 12.292 | 51.789 | 0.000 | 0.798 | 0.000 | 0.000 | -21.801 | 0.000 | -9.488 | -13.568 |
ROOM_6_FLR_3 | 27.490 | -34.965 | 0.000 | -15.844 | 0.000 | 0.000 | 9.755 | 6.366 | 12.291 | 36.701 | 0.000 | 0.794 | 0.000 | 0.000 | -22.119 | 0.000 | -9.357 | -11.111 |
CORRIDOR_FLR_3 | 0.000 | 0.000 | 0.782 | -188.248 | 0.000 | 0.000 | 117.089 | 109.603 | 0.000 | 47.850 | 0.000 | 0.442 | 0.000 | 0.000 | -29.236 | 0.000 | -11.295 | -46.989 |
ROOM_1_FLR_6 | 8.119 | -10.586 | 0.000 | -3.988 | 0.000 | 0.000 | 2.437 | 1.592 | 3.073 | 12.998 | 0.000 | 0.204 | 0.000 | 0.000 | -5.468 | 0.000 | -2.396 | -5.984 |
ROOM_2_FLR_6 | 9.839 | -8.813 | 0.000 | -3.916 | 0.000 | 0.000 | 2.443 | 1.591 | 3.073 | 9.327 | 0.000 | 0.203 | 0.000 | 0.000 | -5.613 | 0.000 | -2.361 | -5.773 |
ROOM_3_MULT9_FLR_6 | 22.313 | -65.632 | 0.000 | -26.275 | 0.000 | 0.000 | 21.840 | 9.005 | 27.097 | 71.514 | 0.000 | 1.141 | 0.000 | 0.000 | -25.760 | 0.000 | -12.013 | -23.229 |
BANQUET_FLR_6 | 0.000 | 0.000 | 0.000 | -435.736 | 0.000 | 0.000 | 317.546 | 34.635 | 175.857 | 10.250 | 0.000 | 0.198 | 0.000 | 0.000 | -17.928 | 0.000 | -6.525 | -78.299 |
DINING_FLR_6 | 0.000 | 0.000 | 0.000 | -474.381 | 0.000 | 0.000 | 316.067 | 34.635 | 175.857 | 10.038 | 0.000 | 0.197 | 0.000 | 0.000 | -18.478 | 0.000 | -6.588 | -37.347 |
KITCHEN_FLR_6 | 0.000 | 0.000 | 0.000 | -625.353 | 0.000 | 0.000 | 28.383 | 13.327 | 550.372 | 24.044 | 0.000 | 0.175 | 27.085 | 0.000 | -12.109 | 0.000 | -5.924 | -0.000 |
CORRIDOR_FLR_6 | 0.000 | 0.000 | 1.010 | -93.349 | 0.000 | 0.000 | 31.130 | 28.999 | 0.000 | 23.313 | 0.000 | 0.180 | 26.824 | 0.000 | -13.117 | 0.000 | -4.992 | -0.000 |
Total Facility | 261.270 | -620.149 | 4.072 | -4527.686 | 0.000 | 0.000 | 1999.234 | 766.542 | 2451.839 | 1024.303 | 0.000 | 16.925 | 58.410 | 0.000 | -547.027 | 0.000 | -270.267 | -617.465 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 27-OCT-21:45 | 0.00 | 0.00 | 0.00 | -38082.82 | 0.00 | 0.00 | 6664.74 | 9457.02 | 7452.27 | 0.00 | 0.00 | 0.00 | 14508.79 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 03-DEC-11:07 | 0.00 | 0.00 | 0.00 | -5384.35 | 0.00 | 0.00 | 225.90 | 234.80 | 288.68 | 7056.06 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -221.44 | -2199.65 |
RETAIL_2_FLR_1 | 26-OCT-22:05 | 0.00 | 0.00 | 0.00 | -3009.01 | 0.00 | 0.00 | 785.25 | 271.91 | 334.29 | 0.00 | 0.00 | 0.00 | 1692.13 | 0.00 | -0.00 | 0.00 | -74.55 | 0.00 |
MECH_FLR_1 | 17-AUG-20:00 | 0.00 | 0.00 | 0.00 | -2247.22 | 0.00 | 0.00 | 129.09 | 1360.40 | 839.45 | 0.00 | 0.00 | 51.44 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -133.15 |
STORAGE_FLR_1 | 26-OCT-22:30 | 0.00 | 0.00 | 0.00 | -1012.55 | 0.00 | 0.00 | 140.24 | 75.91 | 101.96 | 0.00 | 0.00 | 0.00 | 791.73 | 0.00 | -0.00 | 0.00 | -97.29 | 0.00 |
LAUNDRY_FLR_1 | 29-NOV-21:50 | 0.00 | 0.00 | 0.00 | -51652.13 | 0.00 | 0.00 | 426.20 | 317.52 | 41967.83 | 0.00 | 0.00 | 0.00 | 9272.68 | 0.00 | -0.00 | 0.00 | -332.11 | 0.00 |
CAFE_FLR_1 | 17-DEC-10:08 | 0.00 | 0.00 | 0.00 | -22332.02 | 0.00 | 0.00 | 4893.32 | 358.25 | 406.43 | 17664.75 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -421.36 | -569.37 |
LOBBY_FLR_1 | 21-OCT-05:42 | 0.00 | 0.00 | 0.00 | -72507.62 | 0.00 | 0.00 | 20659.06 | 3421.73 | 4222.82 | 0.00 | 0.00 | 0.00 | 47875.99 | 0.00 | -2546.34 | 0.00 | -1125.64 | 0.00 |
ROOM_1_FLR_3 | 07-SEP-15:02 | 0.00 | -13000.66 | 0.00 | -760.95 | 0.00 | 0.00 | 235.28 | 137.21 | 273.93 | 11034.98 | 0.00 | 100.69 | 1979.52 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 12-AUG-15:02 | 0.00 | -12445.70 | 0.00 | -745.52 | 0.00 | 0.00 | 130.72 | 161.69 | 305.51 | 6131.10 | 0.00 | 161.25 | 6300.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 04-OCT-12:10 | 0.00 | -49706.16 | 0.00 | -10830.70 | 0.00 | 0.00 | 0.00 | 1638.34 | 5097.90 | 77444.25 | 0.00 | 162.05 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -23805.68 |
ROOM_4_MULT19_FLR_3 | 11-JUL-15:02 | 0.00 | -66903.23 | 0.00 | -10365.01 | 0.00 | 0.00 | 4470.52 | 1638.79 | 5099.29 | 16627.94 | 0.00 | 768.57 | 48663.14 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 01-AUG-08:62 | 0.00 | -11695.47 | 0.00 | -756.82 | 0.00 | 0.00 | 87.14 | 215.61 | 453.05 | 10722.17 | 0.00 | 112.50 | 861.83 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 02-AUG-08:62 | 0.00 | -11514.39 | 0.00 | -762.20 | 0.00 | 0.00 | 87.14 | 215.58 | 452.99 | 10865.97 | 0.00 | 151.26 | 503.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 26-OCT-22:30 | 0.00 | 0.00 | 0.00 | -13788.10 | 0.00 | 0.00 | 5657.69 | 2987.71 | 0.00 | 0.00 | 0.00 | 0.00 | 7852.87 | 0.00 | -2178.66 | 0.00 | -531.51 | 0.00 |
ROOM_1_FLR_6 | 01-AUG-15:02 | 0.00 | -3410.75 | 0.00 | -190.68 | 0.00 | 0.00 | 58.82 | 34.30 | 68.48 | 2717.19 | 0.00 | 50.44 | 672.20 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 07-JUL-15:02 | 0.00 | -3288.69 | 0.00 | -189.98 | 0.00 | 0.00 | 58.82 | 34.30 | 68.48 | 2109.25 | 0.00 | 58.59 | 1149.25 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 18-AUG-15:02 | 0.00 | -15841.34 | 0.00 | -1224.55 | 0.00 | 0.00 | 529.38 | 194.07 | 603.86 | 6059.53 | 0.00 | 299.31 | 9379.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 06-NOV-23:42 | 0.00 | 0.00 | 0.00 | -38096.59 | 0.00 | 0.00 | 15626.30 | 1031.35 | 6747.90 | 0.00 | 0.00 | 0.00 | 16096.56 | 0.00 | -1115.59 | 0.00 | -289.93 | 0.00 |
DINING_FLR_6 | 19-JAN-23:50 | 0.00 | 0.00 | 0.00 | -39377.34 | 0.00 | 0.00 | 15099.42 | 1031.35 | 6747.90 | 0.00 | 0.00 | 0.00 | 18089.40 | 0.00 | -1258.67 | 0.00 | -332.05 | 0.00 |
KITCHEN_FLR_6 | 30-NOV-13:52 | 0.00 | 0.00 | 0.00 | -40148.67 | 0.00 | 0.00 | 278.82 | 302.73 | 21760.70 | 225.74 | 0.00 | 0.00 | 17847.44 | 0.00 | -0.00 | 0.00 | -266.77 | 0.00 |
CORRIDOR_FLR_6 | 16-AUG-12:50 | 0.00 | 0.00 | 0.00 | -7302.98 | 0.00 | 0.00 | 308.46 | 658.76 | 0.00 | 4052.33 | 0.00 | 111.28 | 2172.15 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 18-AUG-18:02 | 0.00 | -157906.90 | 0.00 | -221106.94 | 0.00 | 0.00 | 73984.50 | 54200.73 | 122326.88 | 25160.97 | 0.00 | 3990.57 | 99350.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 27-OCT-22:30 | 0.00 | 0.00 | 2843.99 | 0.00 | 0.00 | 0.00 | 6609.03 | 4728.51 | 4258.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -18439.97 |
RETAIL_1_FLR_1 | 02-JAN-07:10 | 0.00 | 0.00 | 1434.80 | 0.00 | 0.00 | 0.00 | 357.96 | 391.34 | 433.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1354.48 | 0.00 | -443.71 | -818.92 |
RETAIL_2_FLR_1 | 25-DEC-05:45 | 0.00 | 0.00 | 361.98 | 0.00 | 0.00 | 0.00 | 711.93 | 181.27 | 250.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -64.30 | -1441.59 |
MECH_FLR_1 | 02-JAN-04:50 | 0.00 | 0.00 | 616.03 | 0.00 | 0.00 | 0.00 | 197.30 | 151.16 | 176.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -411.62 | -729.59 |
STORAGE_FLR_1 | 30-NOV-13:53 | 0.00 | 0.00 | 653.51 | 0.00 | 0.00 | 0.00 | 33.66 | 63.26 | 89.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -93.51 | -746.14 |
LAUNDRY_FLR_1 | 16-OCT-03:24 | 0.00 | 0.00 | 3200.12 | 0.00 | 0.00 | 0.00 | 618.28 | 39.69 | 9326.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -211.44 | -12972.84 |
CAFE_FLR_1 | 13-NOV-08:23 | 0.00 | 0.00 | 2794.03 | 0.00 | 0.00 | 0.00 | 4628.35 | 477.67 | 508.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -595.81 | 0.00 | -417.21 | -7395.07 |
LOBBY_FLR_1 | 13-NOV-08:23 | 0.00 | 0.00 | 5051.65 | 0.00 | 0.00 | 0.00 | 12861.81 | 4242.94 | 5278.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -964.51 | 0.00 | -1280.39 | -25190.04 |
ROOM_1_FLR_3 | 06-FEB-19:01 | 10790.81 | 303.53 | 0.00 | -303.53 | 0.00 | 0.00 | 419.21 | 436.12 | 516.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2836.85 | 0.00 | -842.65 | -8482.91 |
ROOM_2_FLR_3 | 06-FEB-09:01 | 10844.29 | 298.61 | 0.00 | -298.61 | 0.00 | 0.00 | 108.88 | 215.58 | 452.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2044.47 | 0.00 | -969.23 | -8608.04 |
ROOM_3_MULT19_FLR_3 | 02-JAN-05:00 | 19243.68 | 3440.39 | 0.00 | -3440.39 | 0.00 | 0.00 | 0.00 | 643.59 | 3921.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -16735.07 | 0.00 | -5222.11 | -1851.55 |
ROOM_4_MULT19_FLR_3 | 06-FEB-16:01 | 60356.72 | 3809.18 | 0.00 | -3809.18 | 0.00 | 0.00 | 5585.75 | 1638.79 | 5099.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12149.81 | 0.00 | -4213.27 | -56317.47 |
ROOM_5_FLR_3 | 14-JAN-16:02 | 10531.75 | 302.88 | 0.00 | -302.88 | 0.00 | 0.00 | 163.33 | 161.71 | 305.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2410.89 | 0.00 | -790.99 | -7960.45 |
ROOM_6_FLR_3 | 02-JAN-16:01 | 10557.43 | 298.11 | 0.00 | -298.11 | 0.00 | 0.00 | 293.99 | 137.19 | 273.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2185.52 | 0.00 | -786.98 | -8290.02 |
CORRIDOR_FLR_3 | 30-NOV-13:53 | 0.00 | 0.00 | 5707.07 | 0.00 | 0.00 | 0.00 | 1381.50 | 2489.76 | 0.00 | 2274.05 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -500.28 | -11352.10 |
ROOM_1_FLR_6 | 06-FEB-19:01 | 3160.20 | 76.48 | 0.00 | -76.48 | 0.00 | 0.00 | 104.80 | 109.03 | 129.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -708.97 | 0.00 | -211.40 | -2582.72 |
ROOM_2_FLR_6 | 06-FEB-09:01 | 3170.44 | 75.22 | 0.00 | -75.22 | 0.00 | 0.00 | 27.22 | 53.90 | 113.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -514.75 | 0.00 | -243.05 | -2607.02 |
ROOM_3_MULT9_FLR_6 | 14-JAN-16:02 | 14824.03 | 485.57 | 0.00 | -485.57 | 0.00 | 0.00 | 367.48 | 228.73 | 673.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2772.89 | 0.00 | -912.58 | -12408.30 |
BANQUET_FLR_6 | 27-OCT-21:47 | 0.00 | 0.00 | 555.21 | 0.00 | 0.00 | 0.00 | 15639.39 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1126.44 | 0.00 | -302.85 | -23575.91 |
DINING_FLR_6 | 27-OCT-21:47 | 0.00 | 0.00 | 468.92 | 0.00 | 0.00 | 0.00 | 15636.92 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1148.33 | 0.00 | -303.57 | -23464.56 |
KITCHEN_FLR_6 | 18-OCT-01:46 | 0.00 | 0.00 | 374.41 | 0.00 | 0.00 | 0.00 | 1507.34 | 121.09 | 5415.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -919.48 | 0.00 | -255.55 | -6243.79 |
CORRIDOR_FLR_6 | 02-JAN-07:10 | 0.00 | 0.00 | 2522.84 | 0.00 | 0.00 | 0.00 | 733.32 | 1317.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1766.14 | 0.00 | -552.88 | -2254.65 |
Total Facility | 14-JAN-16:02 | 66920.02 | 81424.58 | 7212.40 | -81424.58 | 0.00 | 0.00 | 36286.90 | 17988.09 | 78718.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -57235.68 | 0.00 | -20291.30 | -129598.67 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 22.0915 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 21.9688 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0513 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 2.0513 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 11.6643 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 11.6643 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0513 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 2.0513 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BASEMENT | VAV WITH REHEAT | 0.000000 | 106.4990 | 0.000432 | 1978.83 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | 0.000000 | 10.8290 | 0.001181 | 67.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | 0.000000 | 12.5400 | 0.001181 | 77.67 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
MECH_FLR_1 | VAV WITH REHEAT | 0.000000 | 2.6520 | 0.000000 | 164.24 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | 0.000000 | 2.0400 | 0.000610 | 94.76 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | 0.000000 | 8.4000 | 0.000000 | 78.04 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | 0.000000 | 142.3000 | 0.003581 | 188.86 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | 0.000000 | 422.4350 | 0.001448 | 1308.19 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1863.81 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1864.32 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | 0.000000 | 83.8280 | 0.000305 | 1557.62 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000396 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000396 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.000000 | 13.5000 | 0.000449 | 220.77 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003581 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
DINING_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003581 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | 0.000000 | 22.2380 | 0.003556 | 103.30 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | 0.000000 | 22.1800 | 0.000305 | 412.12 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
VAV WITH REHEAT | 0.00 | 0.001045 | 6694.0231 | 0.0000 | 0.0000 | 0.0000 | |
FLR_3_DOAS | 0.00 | 0.000441 | 4651.2638 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5173 | 2.5173 | 1.3291 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3885 | 0.3885 | 0.2051 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2403 | 0.2403 | 0.1269 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2335 | 0.2335 | 0.1233 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1132 | 0.1132 | 0.0598 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.2642 | 3.2642 | 1.7235 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5678 | 1.5678 | 0.8278 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 4.7613 | 4.7613 | 2.5140 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8371 | 0.8371 | 0.8371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8373 | 0.8373 | 0.8373 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5041 | 1.5041 | 0.7942 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0992 | 0.0992 | 0.0992 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.1764 | 2.1764 | 1.1491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.2808 | 2.2808 | 1.2042 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.2695 | 2.2695 | 1.1983 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7746 | 0.7746 | 0.4090 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 22.0915 | 21.9688 | 22.0915 | 11.6643 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0513 | 2.0513 | 2.0513 | 2.0513 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3291 | 1.3291 | 1.3291 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2051 | 0.2051 | 0.2051 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1269 | 0.1269 | 0.1269 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1233 | 0.1233 | 0.1233 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0598 | 0.0598 | 0.0598 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.7235 | 1.7235 | 1.7235 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8278 | 0.8278 | 0.8278 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5140 | 2.5140 | 2.5140 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8371 | 0.8371 | 0.8371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8373 | 0.8373 | 0.8373 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7942 | 0.7942 | 0.7942 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0992 | 0.0992 | 0.0992 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1491 | 1.1491 | 1.1491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2042 | 1.2042 | 1.2042 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1983 | 1.1983 | 1.1983 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4090 | 0.4090 | 0.4090 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 11.6643 | 11.6643 | 11.6643 | 11.6643 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0513 | 2.0513 | 2.0513 | 2.0513 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 |
Total gross floor area [m2] | 11345.29 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BASEMENT | 1978.83 | 1978.83 | 0.00 | 168.00 |
RETAIL_1_FLR_1 | 67.07 | 67.07 | 0.00 | 168.00 |
RETAIL_2_FLR_1 | 77.67 | 77.67 | 0.00 | 168.00 |
MECH_FLR_1 | 164.24 | 164.24 | 0.00 | 168.00 |
STORAGE_FLR_1 | 94.76 | 94.76 | 0.00 | 168.00 |
LAUNDRY_FLR_1 | 78.04 | 78.04 | 0.00 | 168.00 |
CAFE_FLR_1 | 188.86 | 188.86 | 0.00 | 168.00 |
LOBBY_FLR_1 | 1308.19 | 1308.19 | 0.00 | 168.00 |
ROOM_1_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT19_FLR_3 | 24.52 | 24.52 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 24.53 | 24.53 | 0.00 | 168.00 |
ROOM_5_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_6_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
CORRIDOR_FLR_3 | 389.40 | 389.40 | 0.00 | 168.00 |
ROOM_1_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT9_FLR_6 | 24.53 | 24.53 | 0.00 | 168.00 |
BANQUET_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
DINING_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
KITCHEN_FLR_6 | 103.30 | 103.30 | 0.00 | 168.00 |
CORRIDOR_FLR_6 | 412.12 | 412.12 | 0.00 | 168.00 |
Totals | 11345.29 | 11345.29 | 0.00 |
Data | |
Number of hours heating loads not met | 2.50 |
Number of hours cooling loads not met | 310.50 |
Number of hours not met | 313.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler | 0.00 | 0.00 | 761.81 | 259652.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 1189.20 | 203778.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 766.54 | 62892.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 242.55 | 15448.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 959.56 | 59492.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Cooking | 762.04 | 29240.64 | 1198.64 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInFreezer | 14.43 | 457.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInRefrigerator | 8.99 | 285.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Laundry | 0.00 | 0.00 | 590.20 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 32.45 | 1868.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLift | 616.11 | 37691.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLightsFan | 2.91 | 188.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 571.72 | 44313.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 129.27 | 7648.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- General | 222.27 | 9938.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 90.75 | 4738.56 | 3097.94 | 297324.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- General | 7.09 | 2093.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- LowTempRefrigeration | 20.46 | 2049.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- MedTempRefrigeration | 34.47 | 1245.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1807.04 | 5670.82 |
Natural Gas | 1788.84 | 5648.58 |
Additional | 0.00 | 0.00 |
Total | 3595.87 | 11319.41 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 67.56 |
Space Heating | 0.00 |
Space Cooling | 104.82 |
Fans (All) | 50.39 |
Service Water Heating | 8.00 |
Receptacle Equipment | 153.81 |
Miscellaneous (All) | 499.84 |
Subtotal | 499.84 |
Natural Gas [MJ/m2] | |
Space Heating | 67.15 |
Service Water Heating | 273.06 |
Miscellaneous (All) | 497.88 |
Subtotal | 497.88 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 6.77 |
Space Heating | 6.73 |
Space Cooling | 10.51 |
Fans (All) | 5.05 |
Service Water Heating | 28.17 |
Receptacle Equipment | 31.22 |
Miscellaneous | 11.55 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_KITCHEN | 3061. | 8760. |
LTG_SCH_DINING | 3061. | 8760. |
LTG_SCH_BASEMENT | 2667. | 8760. |
LTG_SCH_LOBBY | 3061. | 8760. |
LTG_SCH_STORAGE | 1339. | 8760. |
LTG_SCH_MECHANIC | 3061. | 8760. |
LTG_SCH_LAUNDRY | 2678. | 8760. |
LTG_SCH_GUESTROOM | 2482. | 8760. |
LTG_SCH_CORRIDOR | 3061. | 8760. |
LTG_SCH_RETAIL | 2678. | 8760. |
WALKIN_OCC_LGHT_SCH_2 | 1591. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
BASEMENT_EQUIP_SCH | 3924. | 8760. |
BLDG_EQUIP_SCH | 3924. | 8760. |
GUESTROOM_EQP_SCH_BASE | 3239. | 8760. |
GUESTROOM_EQP_SCH_ADVA | 2762. | 8760. |
LOBBY_EQP_SCH | 3292. | 8760. |
OFFICE_EQP_SCH | 4941. | 8760. |
EMPLOYEELOUNGE_EQP_SCH | 4044. | 8760. |
LAUNDRYROOM_EQP_ELEC_SCH | 2920. | 2920. |
LAUNDRYROOM_EQP_GAS_SCH | 2920. | 2920. |
MEETINGROOM_EQP_SCH | 1336. | 4745. |
EXERCISEROOM_EQP_SCH | 3832. | 5840. |
KITCHEN_ELEC_EQUIP_SCH | 2172. | 8760. |
KITCHEN_GAS_EQUIP_SCH | 1332. | 8760. |
KITCHEN_EXHAUST_SCH | 6205. | 6205. |
BLDG_ELEVATORS | 2270. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
BLDG_OCC_SCH | 5026. | 8760. |
GUESTROOM_OCC_SCH | 5515. | 8760. |
LOBBY_OCC_SCH | 2304. | 8760. |
OFFICE_OCC_SCH | 3954. | 8760. |
EMPLOYEELOUNGE_OCC_SCH | 948. | 5475. |
MEETINGROOM_OCC_SCH | 1168. | 4745. |
LAUNDRYROOM_OCC_SCH | 427. | 2920. |
EXERCISEROOM_OCC_SCH | 5292. | 5840. |
INFIL_SCH | 8760. | 8760. |
INFIL_HALF_ON_SCH | 4380. | 8760. |
INFIL_QUARTER_ON_SCH | 2190. | 8760. |
LAUNDRY_SWH_SCH | 2555. | 2555. |
BLDG_SWH_SCH | 3301. | 8760. |
GUESTROOM_SWH_SCH | 2899. | 8760. |
LAUNDRYROOM_SWH_SCH | 2920. | 2920. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
ALWAYS_ON | 8760. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
OCC_GUESTROOM_VENT_CTRL_30MIN | 6570. | 6570. |
OCC_GUESTROOM_VENT_CTRL_20MIN | 6327. | 6327. |
VAC_GUESTROOM_VENTILATION_SCHEDULE | 365. | 365. |
MINOA_MOTORIZEDDAMPER_SCHED | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
ROOM_1_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6_CASE:1_WALKINFREEZER_CASECREDITREDUXSCHED | 2774. | 8760. |
FLR_3_DOAS_OAMINOAFRACSCHEDULE | 8760. | 8760. |
KITCHEN EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 5740. | 6205. |
LAUNDRY_FLR_1 EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 0. | 0. |
SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 3285. | 3285. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
VACGUESTROOM_HTGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 18.89 | 365 | 18.89 | 365 |
VACGUESTROOM_CLGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 23.33 | 365 |
OBCRESET_S_OCCGUESTROOM_HTGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_S_OCCGUESTROOM_CLGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_HTGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_CLGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
HTGSETP_SCH | BASEMENT DUAL SP CONTROL | January | 21.00 | 365 | 21.00 | 365 |
CLGSETP_SCH | BASEMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 8759.67 | 0.33 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8759.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 0.33 | 0.00 | 0.00 | 0.00 |
Average | 8759.98 | 0.02 | 0.00 | 0.00 | 0.00 |
Sum | 192719.67 | 0.33 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 529331.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 50179.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 59156.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8977.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 5588.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 37203.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 710417.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 2115429.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 100358.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 108265.83 | 3.17 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 105946.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 2115429.00 | 3.17 | 0.00 | 0.00 | 0.00 |
Average | 288886.90 | 0.14 | 0.00 | 0.00 | 0.00 |
Sum | 6355511.83 | 3.17 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 8606.17 | 153.83 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 7796.33 | 963.67 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 7800.50 | 959.50 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 8758.67 | 1.33 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 8730.67 | 29.33 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 8758.33 | 1.67 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 8759.17 | 0.83 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 8759.00 | 1.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 8704.50 | 55.50 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 8756.67 | 3.33 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 8756.67 | 3.33 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 8753.50 | 6.50 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 7727.67 | 1032.33 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 7821.00 | 939.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 8637.83 | 122.17 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 7727.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 1032.33 | 0.00 | 0.00 | 0.00 |
Average | 8565.70 | 194.30 | 0.00 | 0.00 | 0.00 |
Sum | 188445.50 | 4274.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 529331.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 50179.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 57507.33 | 1648.67 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8977.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 5588.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 37203.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 593817.50 | 116599.50 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 1780359.17 | 335069.83 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 99393.33 | 964.67 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 1034418.17 | 211296.83 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 1051004.00 | 194711.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 107351.67 | 917.33 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 105946.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 1780359.17 | 335069.83 | 0.00 | 0.00 | 0.00 |
Average | 249741.23 | 39145.81 | 0.00 | 0.00 | 0.00 |
Sum | 5494307.17 | 861207.83 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:59:43
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 0.00 | 8760.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 0.00 | 8760.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 0.00 | 8760.00 | 0.00 | 0.00 |
DINING_FLR_6 | 0.00 | 8760.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 0.00 | 0.00 |
Average | 0.00 | 1592.73 | 0.00 | 0.00 |
Sum | 0.00 | 35040.00 | 0.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 0.00 | 710417.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 0.00 | 2115429.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 0.00 | 1245715.00 | 0.00 | 0.00 |
DINING_FLR_6 | 0.00 | 1245715.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 2115429.00 | 0.00 | 0.00 |
Average | 0.00 | 241694.36 | 0.00 | 0.00 |
Sum | 0.00 | 5317276.00 | 0.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4A
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_NEWYORK
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 1.168 |
February | -0.18 |
March | 5.585 |
April | 10.941 |
May | 16.049 |
June | 21.711 |
July | 25.046 |
August | 24.788 |
September | 19.956 |
October | 14.024 |
November | 7.310 |
December | 3.332 |
Annual Sum or Average | 12.554 |
Minimum of Months | -0.18 |
Maximum of Months | 25.046 |
Report: ZoneCoolingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.351118E+11 | 35196.04 | 19-JAN-20:10 | 4.32 | 1.34 | 0.794126E+10 | 4961.90 | 12-JAN-23:10 | 4.32 | 1.34 |
February | 0.298318E+11 | 31136.11 | 01-FEB-20:38 | 5.60 | 3.16 | 0.696870E+10 | 4836.99 | 03-FEB-22:19 | -0.9 | -3.0 |
March | 0.317861E+11 | 22296.35 | 04-MAR-00:46 | 7.98 | 5.94 | 0.757397E+10 | 4769.37 | 06-MAR-22:10 | 9.82 | 5.94 |
April | 0.305831E+11 | 23040.62 | 12-APR-22:27 | 7.20 | 2.66 | 0.712060E+10 | 4712.54 | 14-APR-21:49 | 6.70 | 5.12 |
May | 0.315908E+11 | 21676.78 | 14-MAY-01:02 | 8.80 | 7.21 | 0.723010E+10 | 4531.75 | 03-MAY-21:10 | 8.80 | 7.21 |
June | 0.329413E+11 | 17414.25 | 22-JUN-18:10 | 28.72 | 17.28 | 0.726239E+10 | 4688.42 | 30-JUN-21:19 | 20.00 | 18.86 |
July | 0.362767E+11 | 17905.30 | 11-JUL-18:08 | 26.73 | 16.72 | 0.776146E+10 | 4837.04 | 27-JUL-21:19 | 23.17 | 21.94 |
August | 0.386415E+11 | 19218.40 | 25-AUG-21:00 | 22.80 | 14.70 | 0.804496E+10 | 4837.25 | 30-AUG-21:19 | 22.43 | 18.00 |
September | 0.394788E+11 | 22914.88 | 24-SEP-05:17 | 10.40 | 8.71 | 0.790670E+10 | 4838.45 | 29-SEP-23:10 | 12.02 | 10.24 |
October | 0.423717E+11 | 38083.22 | 27-OCT-21:45 | 7.20 | 3.64 | 0.820192E+10 | 4984.04 | 27-OCT-22:40 | 7.20 | 3.36 |
November | 0.399289E+11 | 37019.61 | 12-NOV-23:40 | 6.10 | 4.78 | 0.793398E+10 | 5080.83 | 30-NOV-23:40 | 5.73 | 2.09 |
December | 0.382984E+11 | 36005.90 | 20-DEC-20:21 | 5.00 | 1.74 | 0.815078E+10 | 4923.29 | 04-DEC-22:30 | 5.00 | 1.74 |
Annual Sum or Average | 0.426841E+12 | 0.920968E+11 | ||||||||
Minimum of Months | 0.298318E+11 | 17414.25 | 4.32 | 1.34 | 0.696870E+10 | 4531.75 | -0.9 | -3.0 | ||
Maximum of Months | 0.423717E+11 | 38083.22 | 28.72 | 17.28 | 0.820192E+10 | 5080.83 | 23.17 | 21.94 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.105760E+10 | 4309.33 | 17-JAN-12:30 | 9.70 | 5.27 | 0.624623E+09 | 388.92 | 19-JAN-22:00 | 5.60 | 1.07 |
February | 0.134462E+10 | 3984.85 | 02-FEB-13:28 | 6.15 | 0.25 | 0.567801E+09 | 364.16 | 16-FEB-02:49 | 2.12 | 0.96 |
March | 0.240104E+10 | 5327.76 | 29-MAR-13:31 | 7.80 | 5.42 | 0.639773E+09 | 410.48 | 24-MAR-21:40 | 7.80 | 5.42 |
April | 0.302422E+10 | 3561.98 | 08-APR-12:30 | 23.60 | 16.18 | 0.627203E+09 | 458.02 | 07-APR-21:30 | 23.60 | 16.18 |
May | 0.411561E+10 | 2938.37 | 14-MAY-01:02 | 8.80 | 7.21 | 0.663997E+09 | 462.61 | 31-MAY-21:30 | 20.25 | 17.49 |
June | 0.490814E+10 | 3120.76 | 19-JUN-13:10 | 34.90 | 23.89 | 0.701618E+09 | 491.82 | 19-JUN-21:19 | 28.53 | 20.50 |
July | 0.559689E+10 | 3322.29 | 08-JUL-12:00 | 32.20 | 26.10 | 0.758537E+09 | 491.82 | 10-JUL-21:19 | 27.03 | 20.02 |
August | 0.614073E+10 | 4061.75 | 18-AUG-12:40 | 33.13 | 20.27 | 0.778468E+09 | 491.82 | 18-AUG-21:40 | 24.27 | 17.61 |
September | 0.515618E+10 | 4457.72 | 01-SEP-13:47 | 31.02 | 17.52 | 0.698266E+09 | 491.81 | 01-SEP-21:10 | 26.60 | 18.09 |
October | 0.496969E+10 | 4470.45 | 04-OCT-12:10 | 24.50 | 18.64 | 0.696547E+09 | 467.71 | 04-OCT-21:30 | 16.95 | 15.74 |
November | 0.231769E+10 | 4683.14 | 18-NOV-11:01 | 6.78 | 3.82 | 0.613904E+09 | 417.53 | 03-NOV-21:30 | 6.78 | 3.82 |
December | 0.149315E+10 | 5384.71 | 03-DEC-11:07 | 6.38 | 2.27 | 0.627924E+09 | 378.96 | 04-DEC-23:19 | 8.13 | 7.50 |
Annual Sum or Average | 0.425256E+11 | 0.799866E+10 | ||||||||
Minimum of Months | 0.105760E+10 | 2938.37 | 6.15 | 0.25 | 0.567801E+09 | 364.16 | 2.12 | 0.96 | ||
Maximum of Months | 0.614073E+10 | 5384.71 | 34.90 | 26.10 | 0.778468E+09 | 491.82 | 28.53 | 20.50 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.222184E+10 | 2001.30 | 19-JAN-23:50 | 5.60 | 1.07 | 0.760202E+09 | 544.36 | 19-JAN-22:00 | 5.60 | 1.07 |
February | 0.208250E+10 | 2029.14 | 18-FEB-16:28 | 6.15 | 2.75 | 0.693511E+09 | 510.94 | 22-FEB-22:19 | 2.20 | -1.0 |
March | 0.265072E+10 | 2108.21 | 04-MAR-00:15 | 8.53 | 6.02 | 0.820677E+09 | 555.73 | 24-MAR-21:40 | 6.10 | 5.79 |
April | 0.280657E+10 | 2254.22 | 12-APR-22:27 | 7.20 | 2.66 | 0.820807E+09 | 569.51 | 07-APR-21:30 | 7.20 | 2.66 |
May | 0.318862E+10 | 2165.37 | 14-MAY-01:02 | 8.80 | 7.21 | 0.888871E+09 | 569.54 | 30-MAY-23:19 | 18.50 | 15.89 |
June | 0.349039E+10 | 2193.43 | 19-JUN-21:00 | 28.90 | 20.74 | 0.907417E+09 | 569.54 | 09-JUN-21:19 | 28.90 | 20.74 |
July | 0.383801E+10 | 2208.17 | 10-JUL-21:00 | 27.20 | 20.22 | 0.949562E+09 | 569.54 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.397749E+10 | 2272.90 | 04-AUG-21:00 | 32.20 | 23.82 | 0.959723E+09 | 569.67 | 18-AUG-02:09 | 25.60 | 18.92 |
September | 0.343335E+10 | 2171.67 | 01-SEP-21:00 | 26.70 | 18.23 | 0.897888E+09 | 569.54 | 28-SEP-21:10 | 16.42 | 11.03 |
October | 0.327482E+10 | 3009.21 | 26-OCT-22:05 | 7.70 | 3.58 | 0.905643E+09 | 569.53 | 04-OCT-23:19 | 7.70 | 3.58 |
November | 0.258553E+10 | 2310.65 | 07-NOV-01:03 | 7.02 | 5.17 | 0.791481E+09 | 565.75 | 03-NOV-21:30 | 7.02 | 5.17 |
December | 0.242936E+10 | 1911.46 | 03-DEC-23:05 | 6.60 | 3.13 | 0.780527E+09 | 527.27 | 04-DEC-22:00 | 8.30 | 7.50 |
Annual Sum or Average | 0.359792E+11 | 0.101763E+11 | ||||||||
Minimum of Months | 0.208250E+10 | 1911.46 | 5.60 | 1.07 | 0.693511E+09 | 510.94 | 2.20 | -1.0 | ||
Maximum of Months | 0.397749E+10 | 3009.21 | 32.20 | 23.82 | 0.959723E+09 | 569.67 | 28.90 | 20.74 |
Report: ZoneCoolingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.870848E+09 | 1726.09 | 19-JAN-23:50 | 5.60 | 1.07 | 0.152440E+09 | 98.24 | 18-JAN-22:10 | 5.60 | 1.07 |
February | 0.768347E+09 | 1401.53 | 18-FEB-15:46 | 6.70 | 3.01 | 0.137653E+09 | 93.99 | 24-FEB-22:10 | 0.32 | -3.7 |
March | 0.178207E+10 | 1847.98 | 04-MAR-00:46 | 7.98 | 5.94 | 0.156571E+09 | 103.29 | 28-MAR-21:10 | 8.22 | 5.85 |
April | 0.230746E+10 | 1992.30 | 12-APR-22:27 | 7.20 | 2.66 | 0.157889E+09 | 111.32 | 10-APR-21:10 | 7.20 | 2.66 |
May | 0.287138E+10 | 1971.56 | 14-MAY-01:02 | 8.80 | 7.21 | 0.176831E+09 | 120.45 | 31-MAY-21:19 | 20.37 | 17.53 |
June | 0.324444E+10 | 1967.22 | 19-JUN-21:00 | 28.90 | 20.74 | 0.187439E+09 | 120.45 | 20-JUN-21:19 | 20.93 | 17.07 |
July | 0.363338E+10 | 2209.59 | 10-JUL-20:00 | 28.30 | 20.24 | 0.199240E+09 | 120.45 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.367460E+10 | 2247.29 | 17-AUG-20:00 | 28.90 | 22.33 | 0.200503E+09 | 120.46 | 30-AUG-21:19 | 22.43 | 18.00 |
September | 0.313130E+10 | 1881.39 | 01-SEP-20:00 | 26.70 | 17.87 | 0.183554E+09 | 120.45 | 14-SEP-21:10 | 24.13 | 17.21 |
October | 0.284189E+10 | 2139.19 | 26-OCT-22:30 | 7.50 | 3.36 | 0.176610E+09 | 116.61 | 05-OCT-21:10 | 7.50 | 3.36 |
November | 0.190888E+10 | 2054.22 | 07-NOV-01:03 | 7.02 | 5.17 | 0.153854E+09 | 106.12 | 03-NOV-21:10 | 7.02 | 5.17 |
December | 0.131016E+10 | 1650.08 | 03-DEC-23:05 | 6.60 | 3.13 | 0.152858E+09 | 96.62 | 04-DEC-22:00 | 8.30 | 7.50 |
Annual Sum or Average | 0.283448E+11 | 0.203544E+10 | ||||||||
Minimum of Months | 0.768347E+09 | 1401.53 | 5.60 | 1.07 | 0.137653E+09 | 93.99 | 0.32 | -3.7 | ||
Maximum of Months | 0.367460E+10 | 2247.29 | 28.90 | 22.33 | 0.200503E+09 | 120.46 | 24.13 | 18.00 |
Report: ZoneCoolingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.194010E+09 | 814.59 | 19-JAN-23:50 | 5.60 | 1.07 | 0.116756E+09 | 71.68 | 19-JAN-23:49 | 5.60 | 1.07 |
February | 0.173555E+09 | 664.79 | 24-FEB-16:21 | 7.25 | 1.62 | 0.105503E+09 | 68.63 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.679148E+09 | 882.97 | 04-MAR-00:46 | 7.98 | 5.94 | 0.118648E+09 | 75.15 | 28-MAR-21:40 | 7.97 | 5.50 |
April | 0.102704E+10 | 940.75 | 12-APR-22:27 | 7.20 | 2.66 | 0.119016E+09 | 81.55 | 10-APR-21:40 | 7.20 | 2.66 |
May | 0.135275E+10 | 934.20 | 14-MAY-01:02 | 8.80 | 7.21 | 0.132997E+09 | 88.76 | 31-MAY-22:10 | 19.78 | 17.36 |
June | 0.152676E+10 | 815.14 | 22-JUN-18:10 | 28.72 | 17.28 | 0.141590E+09 | 92.66 | 19-JUN-21:19 | 28.72 | 17.28 |
July | 0.168763E+10 | 834.80 | 11-JUL-18:08 | 26.73 | 16.72 | 0.151580E+09 | 92.66 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.170316E+10 | 874.09 | 04-AUG-21:00 | 32.20 | 23.82 | 0.152697E+09 | 92.66 | 18-AUG-21:00 | 23.90 | 17.61 |
September | 0.147691E+10 | 818.03 | 01-SEP-18:08 | 27.70 | 17.44 | 0.138606E+09 | 92.60 | 01-SEP-21:40 | 26.30 | 17.68 |
October | 0.134215E+10 | 1012.55 | 26-OCT-22:30 | 7.50 | 3.36 | 0.133087E+09 | 85.94 | 05-OCT-22:10 | 7.50 | 3.36 |
November | 0.774080E+09 | 979.73 | 07-NOV-01:03 | 7.02 | 5.17 | 0.116289E+09 | 77.89 | 03-NOV-22:10 | 7.02 | 5.17 |
December | 0.352494E+09 | 779.49 | 03-DEC-23:05 | 6.60 | 3.13 | 0.116796E+09 | 70.94 | 04-DEC-22:00 | 8.30 | 7.50 |
Annual Sum or Average | 0.122897E+11 | 0.154357E+10 | ||||||||
Minimum of Months | 0.173555E+09 | 664.79 | 5.60 | 1.07 | 0.105503E+09 | 68.63 | 5.22 | 1.07 | ||
Maximum of Months | 0.170316E+10 | 1012.55 | 32.20 | 23.82 | 0.152697E+09 | 92.66 | 28.72 | 17.68 |
Report: ZoneCoolingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.469486E+11 | 50707.70 | 03-JAN-20:46 | 5.87 | 5.03 | 0.578074E+09 | 502.61 | 19-JAN-23:10 | 5.60 | 1.07 |
February | 0.424248E+11 | 50701.00 | 01-FEB-20:38 | 5.60 | 3.16 | 0.522180E+09 | 419.21 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.486605E+11 | 50495.57 | 20-MAR-19:27 | 4.70 | 4.11 | 0.590140E+09 | 446.54 | 20-MAR-21:19 | 5.00 | 4.51 |
April | 0.482437E+11 | 50163.61 | 13-APR-19:15 | 5.00 | 4.66 | 0.569857E+09 | 518.86 | 19-APR-21:40 | 6.70 | 3.78 |
May | 0.515070E+11 | 38626.70 | 01-MAY-20:20 | 9.40 | 5.24 | 0.591582E+09 | 415.42 | 01-MAY-02:39 | 9.40 | 5.24 |
June | 0.512672E+11 | 38917.85 | 19-JUN-20:00 | 30.00 | 22.01 | 0.574053E+09 | 382.46 | 22-JUN-21:10 | 25.92 | 16.12 |
July | 0.535536E+11 | 38870.02 | 10-JUL-20:00 | 28.30 | 20.24 | 0.593164E+09 | 381.70 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.539562E+11 | 39016.04 | 04-AUG-20:00 | 32.20 | 24.21 | 0.595144E+09 | 381.79 | 25-AUG-21:10 | 22.52 | 14.69 |
September | 0.506930E+11 | 38752.39 | 01-SEP-20:00 | 26.70 | 17.87 | 0.572182E+09 | 388.22 | 01-SEP-21:10 | 26.60 | 18.09 |
October | 0.510269E+11 | 51194.55 | 27-OCT-20:14 | 7.20 | 3.64 | 0.590367E+09 | 492.52 | 27-OCT-22:40 | 7.20 | 3.36 |
November | 0.471800E+11 | 51648.83 | 29-NOV-21:50 | 4.27 | 3.67 | 0.570423E+09 | 485.99 | 30-NOV-23:40 | 5.73 | 2.09 |
December | 0.474892E+11 | 51124.76 | 20-DEC-20:26 | 5.00 | 1.74 | 0.581611E+09 | 456.99 | 04-DEC-22:30 | 5.00 | 1.74 |
Annual Sum or Average | 0.592951E+12 | 0.692878E+10 | ||||||||
Minimum of Months | 0.424248E+11 | 38626.70 | 4.27 | 1.74 | 0.522180E+09 | 381.70 | 5.00 | 1.07 | ||
Maximum of Months | 0.539562E+11 | 51648.83 | 32.20 | 24.21 | 0.595144E+09 | 518.86 | 26.60 | 18.09 |
Report: ZoneCoolingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.143534E+11 | 16682.81 | 17-JAN-12:30 | 9.70 | 5.27 | 0.875564E+10 | 6512.51 | 19-JAN-23:49 | 5.60 | 1.07 |
February | 0.142941E+11 | 16885.66 | 02-FEB-13:28 | 6.15 | 0.25 | 0.805150E+10 | 5950.32 | 22-FEB-22:40 | 2.20 | -0.9 |
March | 0.178005E+11 | 21774.34 | 29-MAR-13:31 | 7.80 | 5.42 | 0.948781E+10 | 6580.01 | 27-MAR-00:49 | 7.80 | 5.42 |
April | 0.184817E+11 | 14672.54 | 12-APR-22:27 | 7.20 | 2.66 | 0.938475E+10 | 6503.96 | 12-APR-23:10 | 7.12 | 2.93 |
May | 0.207873E+11 | 13645.87 | 14-MAY-01:02 | 8.80 | 7.21 | 0.101110E+11 | 6727.33 | 01-MAY-02:39 | 8.80 | 7.21 |
June | 0.223254E+11 | 12165.10 | 19-JUN-21:10 | 28.72 | 20.62 | 0.102718E+11 | 6462.04 | 26-JUN-04:19 | 20.60 | 16.81 |
July | 0.247168E+11 | 11999.50 | 10-JUL-21:10 | 27.12 | 20.12 | 0.107523E+11 | 6462.02 | 11-JUL-04:19 | 19.80 | 15.19 |
August | 0.264648E+11 | 13747.94 | 19-AUG-13:00 | 27.20 | 15.80 | 0.108897E+11 | 6465.09 | 18-AUG-02:09 | 27.20 | 15.80 |
September | 0.234365E+11 | 15303.21 | 30-SEP-12:40 | 20.40 | 12.36 | 0.102318E+11 | 6466.59 | 29-SEP-23:10 | 20.40 | 12.36 |
October | 0.236247E+11 | 17885.02 | 08-OCT-09:30 | 7.75 | 3.26 | 0.104475E+11 | 6750.80 | 16-OCT-03:49 | 8.40 | 7.79 |
November | 0.172604E+11 | 20025.62 | 18-NOV-11:01 | 6.78 | 3.82 | 0.910283E+10 | 6584.07 | 09-NOV-03:09 | 6.78 | 3.82 |
December | 0.158820E+11 | 22336.11 | 17-DEC-10:08 | 8.68 | 4.02 | 0.899025E+10 | 6232.49 | 04-DEC-00:10 | 8.68 | 4.02 |
Annual Sum or Average | 0.239428E+12 | 0.116477E+12 | ||||||||
Minimum of Months | 0.142941E+11 | 11999.50 | 6.15 | 0.25 | 0.805150E+10 | 5950.32 | 2.20 | -0.9 | ||
Maximum of Months | 0.264648E+11 | 22336.11 | 28.72 | 20.62 | 0.108897E+11 | 6750.80 | 27.20 | 16.81 |
Report: ZoneCoolingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.519169E+11 | 45976.30 | 19-JAN-22:50 | 5.60 | 1.07 | 0.275858E+11 | 19238.26 | 19-JAN-23:49 | 5.60 | 1.07 |
February | 0.483557E+11 | 41669.74 | 18-FEB-16:28 | 6.15 | 2.75 | 0.252289E+11 | 18541.96 | 22-FEB-23:10 | 2.20 | -0.8 |
March | 0.581293E+11 | 60311.43 | 28-MAR-21:57 | 7.80 | 5.26 | 0.296471E+11 | 19387.02 | 27-MAR-00:49 | 7.80 | 5.26 |
April | 0.604287E+11 | 65143.00 | 11-APR-21:49 | 8.48 | 1.29 | 0.292852E+11 | 19681.48 | 19-APR-21:40 | 6.70 | 3.78 |
May | 0.678379E+11 | 52077.75 | 16-MAY-04:15 | 8.90 | 7.04 | 0.313543E+11 | 19786.48 | 01-MAY-02:39 | 8.90 | 7.04 |
June | 0.734644E+11 | 42272.40 | 19-JUN-21:10 | 28.72 | 20.62 | 0.311354E+11 | 19185.33 | 04-JUN-23:19 | 28.72 | 20.62 |
July | 0.805368E+11 | 42627.21 | 10-JUL-21:10 | 27.12 | 20.12 | 0.322582E+11 | 19185.26 | 23-JUL-23:19 | 21.47 | 20.57 |
August | 0.830865E+11 | 43844.34 | 04-AUG-21:10 | 31.55 | 23.93 | 0.325412E+11 | 19191.03 | 18-AUG-02:09 | 25.60 | 18.92 |
September | 0.733167E+11 | 42640.86 | 01-SEP-21:10 | 26.60 | 18.09 | 0.310766E+11 | 19194.09 | 29-SEP-23:10 | 12.02 | 10.24 |
October | 0.710048E+11 | 72518.94 | 21-OCT-05:42 | 9.18 | 9.18 | 0.318360E+11 | 19972.44 | 16-OCT-03:49 | 9.18 | 9.18 |
November | 0.571322E+11 | 65370.53 | 06-NOV-22:27 | 7.75 | 5.45 | 0.286964E+11 | 19471.13 | 07-NOV-01:10 | 7.02 | 5.17 |
December | 0.548884E+11 | 45118.47 | 03-DEC-21:50 | 6.42 | 3.42 | 0.284226E+11 | 19062.12 | 04-DEC-22:40 | 8.13 | 7.50 |
Annual Sum or Average | 0.780098E+12 | 0.359068E+12 | ||||||||
Minimum of Months | 0.483557E+11 | 41669.74 | 5.60 | 1.07 | 0.252289E+11 | 18541.96 | 2.20 | -0.8 | ||
Maximum of Months | 0.830865E+11 | 72518.94 | 31.55 | 23.93 | 0.325412E+11 | 19972.44 | 28.72 | 20.62 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 63233586.20 | 2997.06 | 19-JAN-16:01 | 8.22 | 2.84 | 93433940.93 | 56.69 | 12-JAN-22:00 | 8.22 | 2.84 |
February | 87014900.32 | 3011.53 | 02-FEB-16:01 | 4.13 | -2.3 | 84967886.53 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.312890E+09 | 3105.53 | 07-MAR-16:01 | 7.93 | 4.57 | 95743787.40 | 56.69 | 24-MAR-21:10 | 6.10 | 5.64 |
April | 0.685279E+09 | 3272.28 | 10-APR-15:02 | 20.00 | 11.51 | 93541893.05 | 56.69 | 27-APR-22:10 | 14.50 | 12.87 |
May | 0.133324E+10 | 3320.49 | 27-MAY-15:02 | 21.70 | 11.94 | 98119870.61 | 56.70 | 31-MAY-22:10 | 19.78 | 17.36 |
June | 0.219582E+10 | 3353.35 | 15-JUN-15:02 | 26.52 | 22.45 | 95708280.06 | 56.70 | 22-JUN-22:49 | 24.50 | 15.64 |
July | 0.271566E+10 | 3393.51 | 13-JUL-15:02 | 30.32 | 24.44 | 99004112.52 | 56.70 | 14-JUL-00:10 | 26.60 | 22.01 |
August | 0.294559E+10 | 3433.14 | 21-AUG-15:02 | 30.40 | 23.80 | 99113515.81 | 56.70 | 17-AUG-23:10 | 30.40 | 23.80 |
September | 0.183298E+10 | 3440.34 | 07-SEP-15:02 | 26.60 | 22.96 | 95318297.96 | 56.70 | 01-SEP-23:10 | 26.60 | 22.96 |
October | 0.123558E+10 | 3098.24 | 04-OCT-15:02 | 23.72 | 19.12 | 97945728.23 | 56.69 | 04-OCT-00:10 | 23.72 | 19.12 |
November | 0.197203E+09 | 3073.32 | 02-NOV-15:01 | 16.60 | 8.91 | 91984702.58 | 56.69 | 02-NOV-03:39 | 16.60 | 8.91 |
December | 76140362.49 | 2977.34 | 17-DEC-16:01 | 9.82 | 4.16 | 93863428.75 | 56.69 | 25-DEC-05:49 | 8.22 | 8.02 |
Annual Sum or Average | 0.136806E+11 | 0.113875E+10 | ||||||||
Minimum of Months | 63233586.20 | 2977.34 | 4.13 | -2.3 | 84967886.53 | 56.69 | 5.22 | 2.84 | ||
Maximum of Months | 0.294559E+10 | 3440.34 | 30.40 | 24.44 | 99113515.81 | 56.70 | 30.40 | 23.80 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 35621506.65 | 1748.28 | 17-JAN-16:02 | 9.45 | 4.59 | 92681884.31 | 56.69 | 03-JAN-04:19 | 9.45 | 4.59 |
February | 40168069.86 | 2641.80 | 20-FEB-16:02 | 7.12 | 4.40 | 83937165.84 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.178216E+09 | 2986.36 | 07-MAR-16:01 | 7.93 | 4.57 | 94687237.18 | 56.69 | 04-MAR-04:19 | 7.93 | 4.57 |
April | 0.515939E+09 | 3151.99 | 10-APR-15:02 | 20.00 | 11.51 | 93044280.81 | 56.69 | 27-APR-21:30 | 14.40 | 12.98 |
May | 0.122049E+10 | 3222.78 | 27-MAY-15:02 | 21.70 | 11.94 | 97965746.80 | 56.70 | 31-MAY-22:10 | 19.78 | 17.36 |
June | 0.210925E+10 | 3260.17 | 15-JUN-15:02 | 26.52 | 22.45 | 95681640.03 | 56.70 | 22-JUN-22:49 | 24.50 | 15.64 |
July | 0.259727E+10 | 3282.58 | 07-JUL-18:02 | 27.12 | 23.24 | 98992419.72 | 56.70 | 14-JUL-00:10 | 26.60 | 22.01 |
August | 0.264261E+10 | 3297.62 | 12-AUG-15:02 | 28.72 | 24.51 | 99048266.11 | 56.70 | 21-AUG-23:40 | 27.20 | 23.26 |
September | 0.149556E+10 | 3208.28 | 07-SEP-15:02 | 26.60 | 22.96 | 95030275.22 | 56.70 | 14-SEP-21:19 | 23.87 | 17.02 |
October | 0.769521E+09 | 3140.85 | 03-OCT-15:02 | 23.22 | 19.26 | 97047401.48 | 56.69 | 13-OCT-21:19 | 15.20 | 15.20 |
November | 95919349.64 | 2932.76 | 03-NOV-15:02 | 16.83 | 10.88 | 90996828.17 | 56.69 | 17-NOV-00:00 | 8.30 | 7.75 |
December | 41344578.25 | 1189.52 | 17-DEC-19:03 | 7.62 | 3.39 | 92783328.41 | 56.69 | 25-DEC-05:49 | 8.22 | 8.02 |
Annual Sum or Average | 0.117419E+11 | 0.113190E+10 | ||||||||
Minimum of Months | 35621506.65 | 1189.52 | 7.12 | 3.39 | 83937165.84 | 56.69 | 5.22 | 4.49 | ||
Maximum of Months | 0.264261E+10 | 3297.62 | 28.72 | 24.51 | 99048266.11 | 56.70 | 27.20 | 23.26 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.104506E+09 | 198.05 | 19-JAN-14:40 | 9.07 | 3.63 | 0.00 | 0.00 | 01-JAN-00:10 | 9.07 | 3.63 |
February | 0.153722E+09 | 318.22 | 20-FEB-13:23 | 9.15 | 4.45 | 0.00 | 0.00 | 01-FEB-00:10 | 9.15 | 4.45 |
March | 0.241108E+09 | 486.35 | 03-MAR-13:30 | 14.70 | 8.33 | 0.00 | 0.00 | 01-MAR-00:10 | 14.70 | 8.33 |
April | 0.306861E+09 | 633.66 | 08-APR-12:30 | 23.60 | 16.18 | 0.00 | 0.00 | 01-APR-00:10 | 23.60 | 16.18 |
May | 0.408525E+09 | 509.30 | 30-MAY-12:50 | 29.90 | 17.93 | 0.00 | 0.00 | 01-MAY-00:10 | 29.90 | 17.93 |
June | 0.580188E+09 | 536.34 | 19-JUN-13:20 | 34.80 | 23.85 | 0.00 | 0.00 | 01-JUN-00:10 | 34.80 | 23.85 |
July | 0.798393E+09 | 563.59 | 10-JUL-13:10 | 32.30 | 20.52 | 0.00 | 0.00 | 01-JUL-00:10 | 32.30 | 20.52 |
August | 0.919617E+09 | 698.25 | 30-AUG-13:00 | 27.20 | 15.60 | 0.00 | 0.00 | 01-AUG-00:10 | 27.20 | 15.60 |
September | 0.686650E+09 | 742.82 | 30-SEP-12:40 | 20.40 | 12.36 | 0.00 | 0.00 | 01-SEP-00:10 | 20.40 | 12.36 |
October | 0.660289E+09 | 796.57 | 04-OCT-12:10 | 24.50 | 18.64 | 0.00 | 0.00 | 01-OCT-00:10 | 24.50 | 18.64 |
November | 0.275369E+09 | 648.83 | 02-NOV-13:00 | 15.60 | 8.21 | 0.00 | 0.00 | 01-NOV-00:10 | 15.60 | 8.21 |
December | 0.177328E+09 | 492.07 | 17-DEC-13:40 | 12.20 | 5.18 | 0.00 | 0.00 | 01-DEC-00:10 | 12.20 | 5.18 |
Annual Sum or Average | 0.531256E+10 | 0.00 | ||||||||
Minimum of Months | 0.104506E+09 | 198.05 | 9.07 | 3.63 | 0.00 | 0.00 | 9.07 | 3.63 | ||
Maximum of Months | 0.919617E+09 | 796.57 | 34.80 | 23.85 | 0.00 | 0.00 | 34.80 | 23.85 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 55080492.36 | 602.00 | 03-JAN-19:03 | 7.70 | 6.60 | 93836283.16 | 56.69 | 12-JAN-22:10 | 5.10 | 3.43 |
February | 46105887.59 | 580.06 | 01-FEB-19:03 | 6.02 | 3.41 | 84723486.08 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.126525E+09 | 806.93 | 28-MAR-15:02 | 12.80 | 8.42 | 95031148.05 | 56.69 | 28-MAR-21:10 | 8.22 | 5.85 |
April | 0.294948E+09 | 927.76 | 08-APR-15:02 | 20.95 | 14.84 | 92847133.12 | 56.69 | 07-APR-21:19 | 20.95 | 14.84 |
May | 0.568400E+09 | 996.65 | 29-MAY-15:02 | 25.50 | 17.04 | 97109775.90 | 56.69 | 30-MAY-21:10 | 19.32 | 15.31 |
June | 0.796407E+09 | 1011.01 | 20-JUN-15:02 | 26.93 | 17.32 | 94710978.00 | 56.69 | 19-JUN-22:10 | 26.93 | 17.32 |
July | 0.965323E+09 | 1016.69 | 11-JUL-15:02 | 28.30 | 17.52 | 98303850.70 | 56.69 | 10-JUL-21:00 | 28.30 | 17.52 |
August | 0.906293E+09 | 1015.23 | 22-AUG-15:02 | 29.90 | 17.46 | 98191683.53 | 56.69 | 17-AUG-21:40 | 29.90 | 17.46 |
September | 0.622586E+09 | 993.14 | 01-SEP-15:02 | 30.22 | 17.51 | 93941217.41 | 56.69 | 01-SEP-21:10 | 26.60 | 18.09 |
October | 0.367416E+09 | 890.25 | 04-OCT-15:02 | 23.72 | 19.12 | 96139805.94 | 56.69 | 02-OCT-22:49 | 23.72 | 19.12 |
November | 0.143149E+09 | 807.11 | 05-NOV-08:62 | 9.08 | 6.32 | 91932706.62 | 56.69 | 08-NOV-22:10 | 11.78 | 11.28 |
December | 58100455.09 | 466.82 | 29-DEC-19:04 | 5.50 | 5.21 | 94014584.55 | 56.69 | 25-DEC-05:49 | 5.50 | 5.21 |
Annual Sum or Average | 0.495033E+10 | 0.113078E+10 | ||||||||
Minimum of Months | 46105887.59 | 466.82 | 5.50 | 3.41 | 84723486.08 | 56.69 | 5.10 | 3.43 | ||
Maximum of Months | 0.965323E+09 | 1016.69 | 30.22 | 19.12 | 98303850.70 | 56.69 | 29.90 | 19.12 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 76032245.44 | 2446.74 | 19-JAN-09:01 | 4.97 | 3.19 | 93384772.84 | 56.69 | 03-JAN-04:19 | 4.97 | 3.19 |
February | 96377224.86 | 2666.67 | 25-FEB-09:01 | -2.0 | -5.5 | 85021258.12 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.282743E+09 | 2854.21 | 07-MAR-09:01 | 6.38 | 2.56 | 95809224.31 | 56.69 | 24-MAR-21:10 | 6.10 | 5.64 |
April | 0.693317E+09 | 2931.70 | 10-APR-15:02 | 20.00 | 11.51 | 93786680.74 | 56.69 | 06-APR-22:10 | 20.00 | 11.51 |
May | 0.137670E+10 | 3003.40 | 31-MAY-08:62 | 23.17 | 18.85 | 98305162.99 | 56.70 | 31-MAY-21:00 | 19.90 | 17.35 |
June | 0.207925E+10 | 3112.29 | 23-JUN-08:62 | 26.70 | 18.47 | 95779547.94 | 56.70 | 20-JUN-00:10 | 26.70 | 18.47 |
July | 0.267386E+10 | 3082.24 | 13-JUL-15:02 | 30.32 | 24.44 | 99071325.27 | 56.70 | 10-JUL-01:10 | 30.32 | 24.44 |
August | 0.291275E+10 | 3112.89 | 01-AUG-08:62 | 26.97 | 22.14 | 99207012.93 | 56.70 | 03-AUG-00:40 | 26.87 | 23.61 |
September | 0.185099E+10 | 3101.04 | 07-SEP-15:02 | 26.60 | 22.96 | 95427768.24 | 56.70 | 14-SEP-21:30 | 23.60 | 16.82 |
October | 0.118948E+10 | 2969.61 | 03-OCT-15:02 | 23.22 | 19.26 | 98147952.14 | 56.69 | 05-OCT-00:49 | 16.78 | 15.39 |
November | 0.245961E+09 | 2807.85 | 02-NOV-15:01 | 16.60 | 8.91 | 92218420.56 | 56.69 | 03-NOV-21:10 | 12.80 | 10.17 |
December | 0.105328E+09 | 2655.02 | 20-DEC-09:01 | 6.47 | 4.26 | 93879069.07 | 56.69 | 25-DEC-05:49 | 8.22 | 8.02 |
Annual Sum or Average | 0.135828E+11 | 0.114004E+10 | ||||||||
Minimum of Months | 76032245.44 | 2446.74 | -2.0 | -5.5 | 85021258.12 | 56.69 | 4.97 | 3.19 | ||
Maximum of Months | 0.291275E+10 | 3112.89 | 30.32 | 24.44 | 99207012.93 | 56.70 | 30.32 | 24.44 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 34204778.17 | 1106.98 | 26-JAN-09:03 | 0.87 | -2.0 | 92667079.61 | 56.69 | 03-JAN-04:19 | 0.87 | -2.0 |
February | 40449930.97 | 2146.51 | 19-FEB-09:01 | 4.37 | 2.79 | 83960472.13 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.155143E+09 | 2683.05 | 03-MAR-09:02 | 10.78 | 6.54 | 94657750.78 | 56.69 | 04-MAR-04:19 | 7.40 | 6.71 |
April | 0.514223E+09 | 2830.22 | 08-APR-15:02 | 20.95 | 14.84 | 93348110.74 | 56.69 | 07-APR-22:10 | 20.95 | 14.84 |
May | 0.125397E+10 | 2985.42 | 31-MAY-15:02 | 25.82 | 19.50 | 98248910.62 | 56.70 | 31-MAY-21:49 | 20.02 | 17.39 |
June | 0.198999E+10 | 3030.77 | 23-JUN-08:62 | 26.70 | 18.47 | 95774337.42 | 56.70 | 20-JUN-00:10 | 26.70 | 18.47 |
July | 0.255459E+10 | 3043.27 | 14-JUL-08:62 | 27.98 | 20.73 | 99065149.96 | 56.70 | 13-JUL-23:40 | 27.98 | 20.73 |
August | 0.260545E+10 | 3069.06 | 02-AUG-08:62 | 28.48 | 24.65 | 99193172.36 | 56.70 | 17-AUG-23:10 | 26.70 | 20.78 |
September | 0.149960E+10 | 3018.60 | 01-SEP-08:61 | 26.20 | 19.61 | 95266805.90 | 56.70 | 01-SEP-22:00 | 26.10 | 16.86 |
October | 0.712248E+09 | 2732.24 | 02-OCT-15:02 | 22.88 | 16.78 | 97285796.32 | 56.69 | 04-OCT-22:19 | 17.07 | 15.80 |
November | 0.121928E+09 | 2452.06 | 06-NOV-09:02 | 7.98 | 4.28 | 91201203.73 | 56.69 | 17-NOV-00:00 | 8.30 | 7.75 |
December | 43563056.49 | 1035.01 | 09-DEC-09:03 | 0.78 | -0.9 | 92801260.34 | 56.69 | 25-DEC-05:49 | 8.22 | 8.02 |
Annual Sum or Average | 0.115254E+11 | 0.113347E+10 | ||||||||
Minimum of Months | 34204778.17 | 1035.01 | 0.78 | -2.0 | 83960472.13 | 56.69 | 0.87 | -2.0 | ||
Maximum of Months | 0.260545E+10 | 3069.06 | 28.48 | 24.65 | 99193172.36 | 56.70 | 27.98 | 20.78 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.158989E+10 | 2752.87 | 19-JAN-23:50 | 5.60 | 1.07 | 0.120112E+10 | 751.83 | 19-JAN-23:49 | 5.60 | 1.07 |
February | 0.173113E+10 | 3028.69 | 18-FEB-16:28 | 6.15 | 2.75 | 0.108630E+10 | 725.44 | 22-FEB-22:40 | 2.20 | -0.9 |
March | 0.322689E+10 | 2988.01 | 04-MAR-00:46 | 7.98 | 5.94 | 0.123745E+10 | 783.54 | 28-MAR-21:40 | 7.97 | 5.50 |
April | 0.384586E+10 | 3303.42 | 12-APR-22:27 | 7.20 | 2.66 | 0.125931E+10 | 862.25 | 10-APR-21:40 | 7.20 | 2.66 |
May | 0.468405E+10 | 3175.12 | 14-MAY-01:02 | 8.80 | 7.21 | 0.140474E+10 | 931.08 | 31-MAY-21:40 | 20.13 | 17.44 |
June | 0.523483E+10 | 2791.10 | 22-JUN-18:10 | 28.72 | 17.28 | 0.148807E+10 | 951.84 | 20-JUN-21:40 | 28.72 | 17.28 |
July | 0.576598E+10 | 3062.38 | 10-JUL-18:13 | 29.63 | 20.43 | 0.158002E+10 | 951.85 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.594937E+10 | 3145.04 | 22-AUG-19:00 | 26.70 | 15.84 | 0.160009E+10 | 951.89 | 30-AUG-21:19 | 22.43 | 18.00 |
September | 0.510791E+10 | 2808.28 | 01-SEP-18:08 | 27.70 | 17.44 | 0.146122E+10 | 951.83 | 06-SEP-21:19 | 22.60 | 20.77 |
October | 0.475510E+10 | 3447.02 | 26-OCT-22:30 | 7.50 | 3.36 | 0.142676E+10 | 910.51 | 05-OCT-21:40 | 7.50 | 3.36 |
November | 0.302774E+10 | 3350.37 | 07-NOV-01:03 | 7.02 | 5.17 | 0.120880E+10 | 823.08 | 03-NOV-21:49 | 7.02 | 5.17 |
December | 0.214295E+10 | 2645.78 | 03-DEC-23:05 | 6.60 | 3.13 | 0.120303E+10 | 734.95 | 04-DEC-22:00 | 8.30 | 7.50 |
Annual Sum or Average | 0.470617E+11 | 0.161569E+11 | ||||||||
Minimum of Months | 0.158989E+10 | 2645.78 | 5.60 | 1.07 | 0.108630E+10 | 725.44 | 2.20 | -0.9 | ||
Maximum of Months | 0.594937E+10 | 3447.02 | 29.63 | 20.43 | 0.160009E+10 | 951.89 | 28.72 | 20.77 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 51226360.50 | 3137.36 | 19-JAN-16:01 | 8.22 | 2.84 | 93045720.38 | 56.69 | 03-JAN-04:19 | 8.22 | 2.84 |
February | 77488507.25 | 3140.42 | 02-FEB-16:01 | 4.13 | -2.3 | 84584024.85 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.295212E+09 | 3248.98 | 07-MAR-16:01 | 7.93 | 4.57 | 95364856.75 | 56.69 | 24-MAR-21:10 | 6.10 | 5.64 |
April | 0.657775E+09 | 3420.07 | 10-APR-15:02 | 20.00 | 11.51 | 93269849.70 | 56.69 | 07-APR-22:30 | 20.00 | 11.51 |
May | 0.129083E+10 | 3476.98 | 27-MAY-15:02 | 21.70 | 11.94 | 97997941.75 | 56.70 | 30-MAY-21:30 | 19.15 | 15.12 |
June | 0.219098E+10 | 3589.54 | 19-JUN-15:02 | 32.93 | 23.30 | 95647497.48 | 56.70 | 20-JUN-21:40 | 20.77 | 17.22 |
July | 0.276540E+10 | 3569.84 | 07-JUL-15:02 | 31.73 | 23.66 | 98975994.69 | 56.70 | 13-JUL-22:00 | 27.20 | 23.27 |
August | 0.298615E+10 | 3601.34 | 01-AUG-15:02 | 30.50 | 22.68 | 99079798.61 | 56.70 | 04-AUG-23:49 | 28.30 | 23.48 |
September | 0.175592E+10 | 3556.16 | 07-SEP-15:02 | 26.60 | 22.96 | 95192281.39 | 56.70 | 01-SEP-22:10 | 26.60 | 22.96 |
October | 0.109409E+10 | 3364.89 | 04-OCT-15:02 | 23.72 | 19.12 | 97671858.43 | 56.69 | 12-OCT-21:49 | 15.68 | 15.68 |
November | 0.151812E+09 | 3205.02 | 02-NOV-15:01 | 16.60 | 8.91 | 91473650.54 | 56.69 | 02-NOV-02:39 | 16.60 | 8.91 |
December | 61284774.87 | 3121.90 | 17-DEC-16:01 | 9.82 | 4.16 | 93401055.92 | 56.69 | 25-DEC-05:49 | 8.22 | 8.02 |
Annual Sum or Average | 0.133782E+11 | 0.113570E+10 | ||||||||
Minimum of Months | 51226360.50 | 3121.90 | 4.13 | -2.3 | 84584024.85 | 56.69 | 5.22 | 2.84 | ||
Maximum of Months | 0.298615E+10 | 3601.34 | 32.93 | 23.66 | 99079798.61 | 56.70 | 28.30 | 23.48 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 21254829.93 | 1034.39 | 20-JAN-16:02 | 6.93 | 3.71 | 92456478.36 | 56.69 | 12-JAN-22:00 | 6.93 | 3.71 |
February | 27350120.78 | 2184.20 | 20-FEB-16:02 | 7.12 | 4.40 | 83692945.14 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.157838E+09 | 3099.07 | 07-MAR-16:01 | 7.93 | 4.57 | 94293675.89 | 56.69 | 27-MAR-21:10 | 14.13 | 10.87 |
April | 0.484093E+09 | 3284.36 | 10-APR-15:02 | 20.00 | 11.51 | 92764527.02 | 56.69 | 27-APR-21:10 | 14.40 | 13.08 |
May | 0.116962E+10 | 3366.92 | 27-MAY-15:02 | 21.70 | 11.94 | 97860868.28 | 56.70 | 17-MAY-01:00 | 21.70 | 11.94 |
June | 0.210048E+10 | 3362.85 | 02-JUN-15:02 | 22.20 | 12.50 | 95626181.69 | 56.70 | 19-JUN-23:40 | 25.17 | 21.12 |
July | 0.264173E+10 | 3478.61 | 07-JUL-15:02 | 31.73 | 23.66 | 98965790.44 | 56.70 | 13-JUL-22:00 | 27.20 | 23.27 |
August | 0.266740E+10 | 3477.21 | 04-AUG-15:02 | 31.02 | 25.38 | 99006525.37 | 56.70 | 21-AUG-22:40 | 27.40 | 23.29 |
September | 0.139606E+10 | 3318.77 | 11-SEP-15:02 | 20.50 | 12.46 | 94895031.22 | 56.70 | 01-SEP-21:19 | 20.50 | 12.46 |
October | 0.633008E+09 | 3289.54 | 03-OCT-15:02 | 23.22 | 19.26 | 96653420.93 | 56.69 | 19-OCT-21:30 | 13.30 | 11.74 |
November | 70130543.68 | 3013.85 | 03-NOV-15:02 | 16.83 | 10.88 | 90524961.23 | 56.69 | 03-NOV-21:10 | 12.80 | 10.17 |
December | 28457176.73 | 1166.15 | 08-DEC-16:03 | 5.92 | 1.77 | 92458287.20 | 56.69 | 05-DEC-02:49 | 5.92 | 1.77 |
Annual Sum or Average | 0.113974E+11 | 0.112920E+10 | ||||||||
Minimum of Months | 21254829.93 | 1034.39 | 5.92 | 1.77 | 83692945.14 | 56.69 | 5.22 | 1.77 | ||
Maximum of Months | 0.266740E+10 | 3478.61 | 31.73 | 25.38 | 99006525.37 | 56.70 | 27.40 | 23.29 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.158385E+09 | 1709.72 | 20-JAN-16:01 | 6.93 | 3.71 | 94846913.17 | 56.69 | 19-JAN-22:10 | 6.93 | 3.71 |
February | 0.212831E+09 | 1693.98 | 02-FEB-16:01 | 4.13 | -2.3 | 86570956.89 | 56.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.368655E+09 | 1713.89 | 07-MAR-16:01 | 7.93 | 4.57 | 96473868.29 | 56.69 | 15-MAR-21:10 | 9.82 | 3.29 |
April | 0.504542E+09 | 1783.54 | 10-APR-15:02 | 20.00 | 11.51 | 93766446.88 | 56.69 | 07-APR-22:10 | 20.00 | 11.51 |
May | 0.765961E+09 | 1804.61 | 27-MAY-15:02 | 21.70 | 11.94 | 97954413.01 | 56.69 | 31-MAY-21:40 | 20.13 | 17.44 |
June | 0.118218E+10 | 1843.16 | 15-JUN-15:02 | 26.52 | 22.45 | 95504425.35 | 56.69 | 19-JUN-23:00 | 24.40 | 21.27 |
July | 0.156123E+10 | 1845.88 | 16-JUL-15:02 | 30.50 | 21.72 | 98939873.36 | 56.70 | 20-JUL-22:00 | 26.10 | 24.12 |
August | 0.177383E+10 | 1896.18 | 18-AUG-15:02 | 32.80 | 20.65 | 99046718.28 | 56.70 | 04-AUG-21:10 | 32.80 | 20.65 |
September | 0.130543E+10 | 1863.40 | 06-SEP-15:02 | 26.02 | 20.15 | 95314469.23 | 56.70 | 02-SEP-00:00 | 26.02 | 20.15 |
October | 0.115438E+10 | 1836.37 | 04-OCT-15:02 | 23.72 | 19.12 | 98269785.01 | 56.69 | 10-OCT-21:10 | 14.32 | 14.08 |
November | 0.352419E+09 | 1718.75 | 02-NOV-15:01 | 16.60 | 8.91 | 93471869.07 | 56.69 | 02-NOV-21:30 | 12.25 | 6.94 |
December | 0.245776E+09 | 1692.27 | 17-DEC-16:01 | 9.82 | 4.16 | 95449196.71 | 56.69 | 04-DEC-23:49 | 9.82 | 4.16 |
Annual Sum or Average | 0.958561E+10 | 0.114561E+10 | ||||||||
Minimum of Months | 0.158385E+09 | 1692.27 | 4.13 | -2.3 | 86570956.89 | 56.69 | 5.22 | 3.29 | ||
Maximum of Months | 0.177383E+10 | 1896.18 | 32.80 | 22.45 | 99046718.28 | 56.70 | 32.80 | 24.12 |
Report: ZoneCoolingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.297929E+11 | 37322.73 | 19-JAN-23:50 | 5.60 | 1.07 | 0.184545E+11 | 12561.08 | 12-JAN-23:10 | 5.60 | 1.07 |
February | 0.267212E+11 | 27402.85 | 01-FEB-19:50 | 5.68 | 3.21 | 0.166879E+11 | 11430.97 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.327334E+11 | 33084.01 | 11-MAR-23:11 | 7.20 | 4.58 | 0.190280E+11 | 12740.16 | 27-MAR-00:49 | 8.90 | 8.54 |
April | 0.345871E+11 | 34557.15 | 12-APR-22:27 | 7.20 | 2.66 | 0.185032E+11 | 12803.42 | 19-APR-21:40 | 6.70 | 3.78 |
May | 0.396472E+11 | 30965.00 | 16-MAY-03:37 | 8.90 | 6.68 | 0.192791E+11 | 13234.28 | 01-MAY-02:39 | 8.90 | 6.68 |
June | 0.422180E+11 | 23718.41 | 19-JUN-21:20 | 28.53 | 20.50 | 0.187422E+11 | 11390.78 | 03-JUN-04:10 | 28.53 | 20.50 |
July | 0.454390E+11 | 23468.51 | 10-JUL-21:20 | 27.03 | 20.02 | 0.193050E+11 | 11371.15 | 25-JUL-21:19 | 22.60 | 20.76 |
August | 0.451141E+11 | 23825.34 | 04-AUG-21:20 | 30.90 | 23.99 | 0.193798E+11 | 11381.72 | 15-AUG-21:19 | 24.03 | 21.25 |
September | 0.399321E+11 | 24860.44 | 24-SEP-05:36 | 10.20 | 8.63 | 0.186612E+11 | 11629.27 | 29-SEP-03:30 | 11.95 | 8.45 |
October | 0.373097E+11 | 36520.12 | 26-OCT-22:59 | 7.20 | 3.02 | 0.191664E+11 | 12777.13 | 27-OCT-22:40 | 7.20 | 3.36 |
November | 0.316970E+11 | 38099.89 | 06-NOV-23:42 | 7.20 | 5.19 | 0.182683E+11 | 13451.73 | 30-NOV-23:40 | 5.73 | 2.09 |
December | 0.305401E+11 | 30975.27 | 04-DEC-23:34 | 7.97 | 7.50 | 0.186859E+11 | 12335.99 | 04-DEC-23:19 | 7.97 | 7.50 |
Annual Sum or Average | 0.435732E+12 | 0.224162E+12 | ||||||||
Minimum of Months | 0.267212E+11 | 23468.51 | 5.60 | 1.07 | 0.166879E+11 | 11371.15 | 5.22 | 1.07 | ||
Maximum of Months | 0.454390E+11 | 38099.89 | 30.90 | 23.99 | 0.193798E+11 | 13451.73 | 28.53 | 21.25 |
Report: ZoneCoolingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.331103E+11 | 39382.16 | 19-JAN-23:50 | 5.60 | 1.07 | 0.187681E+11 | 12710.09 | 12-JAN-23:10 | 5.60 | 1.07 |
February | 0.296882E+11 | 31706.19 | 01-FEB-19:38 | 5.77 | 3.26 | 0.169650E+11 | 11455.69 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.363985E+11 | 34803.46 | 11-MAR-23:11 | 7.20 | 4.58 | 0.192035E+11 | 12851.00 | 27-MAR-00:49 | 8.90 | 8.54 |
April | 0.381157E+11 | 37689.71 | 12-APR-22:27 | 7.20 | 2.66 | 0.186261E+11 | 12916.55 | 19-APR-21:40 | 6.70 | 3.78 |
May | 0.431351E+11 | 32920.33 | 15-MAY-05:47 | 9.13 | 7.09 | 0.193228E+11 | 13334.68 | 01-MAY-02:39 | 9.13 | 7.09 |
June | 0.451154E+11 | 24925.96 | 19-JUN-21:20 | 28.53 | 20.50 | 0.187547E+11 | 11392.41 | 03-JUN-04:10 | 28.53 | 20.50 |
July | 0.482704E+11 | 24634.72 | 10-JUL-21:20 | 27.03 | 20.02 | 0.193086E+11 | 11382.25 | 25-JUL-21:19 | 22.60 | 20.76 |
August | 0.479015E+11 | 24997.59 | 04-AUG-21:20 | 30.90 | 23.99 | 0.193872E+11 | 11390.04 | 15-AUG-21:19 | 24.03 | 21.25 |
September | 0.428788E+11 | 27452.14 | 24-SEP-05:36 | 10.20 | 8.63 | 0.186886E+11 | 11641.19 | 29-SEP-03:30 | 11.95 | 8.45 |
October | 0.405729E+11 | 37121.84 | 26-OCT-22:59 | 7.20 | 3.02 | 0.192453E+11 | 12851.37 | 27-OCT-22:40 | 7.20 | 3.36 |
November | 0.351539E+11 | 36241.84 | 06-NOV-23:42 | 7.20 | 5.19 | 0.184537E+11 | 13581.99 | 30-NOV-23:40 | 5.73 | 2.09 |
December | 0.340362E+11 | 32732.11 | 04-DEC-23:34 | 7.97 | 7.50 | 0.189174E+11 | 12444.52 | 04-DEC-23:19 | 7.97 | 7.50 |
Annual Sum or Average | 0.474377E+12 | 0.225641E+12 | ||||||||
Minimum of Months | 0.296882E+11 | 24634.72 | 5.60 | 1.07 | 0.169650E+11 | 11382.25 | 5.22 | 1.07 | ||
Maximum of Months | 0.482704E+11 | 39382.16 | 30.90 | 23.99 | 0.193872E+11 | 13581.99 | 28.53 | 21.25 |
Report: ZoneCoolingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.470724E+11 | 38400.91 | 19-JAN-23:50 | 5.60 | 1.07 | 0.187901E+11 | 11474.73 | 21-JAN-18:40 | 7.20 | 6.67 |
February | 0.427104E+11 | 37508.55 | 18-FEB-16:28 | 6.15 | 2.75 | 0.169691E+11 | 11341.87 | 16-FEB-18:40 | 6.15 | 2.75 |
March | 0.500855E+11 | 36665.68 | 29-MAR-15:51 | 7.20 | 4.88 | 0.188312E+11 | 11430.24 | 04-MAR-18:49 | 7.20 | 4.88 |
April | 0.508421E+11 | 35598.79 | 19-APR-09:21 | 8.05 | 3.80 | 0.182285E+11 | 11406.73 | 01-APR-17:40 | 8.05 | 3.80 |
May | 0.554392E+11 | 32986.96 | 15-MAY-05:54 | 9.40 | 7.22 | 0.188462E+11 | 11319.66 | 13-MAY-17:19 | 9.40 | 7.22 |
June | 0.559221E+11 | 32864.94 | 22-JUN-18:10 | 28.72 | 17.28 | 0.182548E+11 | 11319.69 | 17-JUN-17:19 | 28.72 | 17.28 |
July | 0.590982E+11 | 32413.64 | 11-JUL-18:08 | 26.73 | 16.72 | 0.188615E+11 | 11319.69 | 01-JUL-17:19 | 26.73 | 16.72 |
August | 0.593519E+11 | 34838.51 | 24-AUG-16:57 | 33.30 | 18.04 | 0.188694E+11 | 11319.69 | 19-AUG-17:19 | 33.30 | 18.04 |
September | 0.547658E+11 | 31476.78 | 01-SEP-18:08 | 27.70 | 17.44 | 0.182433E+11 | 11319.66 | 02-SEP-17:19 | 22.93 | 18.77 |
October | 0.539628E+11 | 35655.36 | 27-OCT-07:40 | 6.83 | 3.85 | 0.188387E+11 | 11472.66 | 28-OCT-17:30 | 8.85 | 2.90 |
November | 0.482018E+11 | 40163.50 | 30-NOV-13:52 | 6.70 | 3.52 | 0.182168E+11 | 11548.04 | 18-NOV-18:00 | 6.70 | 3.52 |
December | 0.479115E+11 | 36135.94 | 04-DEC-17:11 | 7.57 | 6.79 | 0.188029E+11 | 11442.49 | 16-DEC-18:00 | 6.70 | 2.70 |
Annual Sum or Average | 0.625364E+12 | 0.221752E+12 | ||||||||
Minimum of Months | 0.427104E+11 | 31476.78 | 5.60 | 1.07 | 0.169691E+11 | 11319.66 | 6.15 | 2.70 | ||
Maximum of Months | 0.593519E+11 | 40163.50 | 33.30 | 18.04 | 0.188694E+11 | 11548.04 | 33.30 | 18.77 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.243984E+10 | 5736.76 | 19-JAN-12:07 | 7.57 | 3.88 | 0.127018E+10 | 787.98 | 19-JAN-23:49 | 5.60 | 1.07 |
February | 0.248928E+10 | 6291.45 | 18-FEB-16:28 | 6.15 | 2.75 | 0.114914E+10 | 747.18 | 28-FEB-22:10 | 5.22 | 4.49 |
March | 0.584139E+10 | 6099.13 | 04-MAR-00:46 | 7.98 | 5.94 | 0.130223E+10 | 833.27 | 27-MAR-21:40 | 13.33 | 10.26 |
April | 0.759312E+10 | 6496.83 | 12-APR-22:27 | 7.20 | 2.66 | 0.131712E+10 | 919.65 | 07-APR-21:30 | 7.20 | 2.66 |
May | 0.967060E+10 | 6403.05 | 14-MAY-01:02 | 8.80 | 7.21 | 0.147578E+10 | 998.19 | 31-MAY-21:30 | 20.25 | 17.49 |
June | 0.110323E+11 | 6746.65 | 19-JUN-14:10 | 34.22 | 23.63 | 0.157454E+10 | 1007.40 | 20-JUN-21:19 | 20.93 | 17.07 |
July | 0.124961E+11 | 7130.15 | 08-JUL-12:00 | 32.20 | 26.10 | 0.167436E+10 | 1007.40 | 11-JUL-21:19 | 22.80 | 17.52 |
August | 0.128369E+11 | 7302.76 | 16-AUG-12:50 | 31.93 | 25.44 | 0.168065E+10 | 1007.41 | 30-AUG-21:40 | 22.07 | 17.86 |
September | 0.105316E+11 | 6681.40 | 01-SEP-14:10 | 31.02 | 17.36 | 0.152334E+10 | 1007.39 | 07-SEP-21:19 | 23.70 | 21.42 |
October | 0.936682E+10 | 6812.62 | 26-OCT-22:30 | 7.50 | 3.36 | 0.145411E+10 | 955.55 | 05-OCT-21:40 | 7.50 | 3.36 |
November | 0.560035E+10 | 6638.32 | 07-NOV-01:03 | 7.02 | 5.17 | 0.125687E+10 | 842.97 | 03-NOV-21:40 | 7.02 | 5.17 |
December | 0.345014E+10 | 5329.29 | 03-DEC-23:05 | 6.60 | 3.13 | 0.127165E+10 | 773.12 | 04-DEC-22:00 | 8.30 | 7.50 |
Annual Sum or Average | 0.933484E+11 | 0.169500E+11 | ||||||||
Minimum of Months | 0.243984E+10 | 5329.29 | 6.15 | 2.66 | 0.114914E+10 | 747.18 | 5.22 | 1.07 | ||
Maximum of Months | 0.128369E+11 | 7302.76 | 34.22 | 26.10 | 0.168065E+10 | 1007.41 | 23.70 | 21.42 |
Report: ZoneHeatingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 40848.68 | 408.49 | 19-JAN-23:48 | 5.60 |
February | 1145626.16 | 1364.98 | 24-FEB-16:15 | 7.43 |
March | 11917031.12 | 1951.84 | 20-MAR-15:07 | 6.20 |
April | 13747559.98 | 1985.68 | 20-APR-06:19 | 6.70 |
May | 7841370.04 | 1696.81 | 15-MAY-02:38 | 7.57 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 1157088.81 | 2843.86 | 27-OCT-22:30 | 7.20 |
November | 516552.86 | 2351.61 | 07-NOV-00:43 | 7.20 |
December | 5841.96 | 97.37 | 17-DEC-09:12 | 6.50 |
Annual Sum or Average | 36371919.61 | |||
Minimum of Months | 0.00 | 0.00 | 5.60 | |
Maximum of Months | 13747559.98 | 2843.86 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.524379E+09 | 1435.11 | 02-JAN-07:10 | -11.6 |
February | 0.355748E+09 | 1370.39 | 06-FEB-05:00 | -13.3 |
March | 63607545.46 | 726.76 | 27-MAR-05:50 | 8.22 |
April | 16270450.36 | 775.99 | 20-APR-06:19 | 6.70 |
May | 4840605.19 | 661.91 | 15-MAY-02:38 | 7.57 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 25012.17 | 149.86 | 24-SEP-05:16 | 10.40 |
October | 7426906.93 | 807.33 | 27-OCT-22:30 | 7.20 |
November | 66175306.03 | 913.77 | 30-NOV-13:53 | 6.70 |
December | 0.231111E+09 | 925.15 | 25-DEC-05:55 | 8.30 |
Annual Sum or Average | 0.126958E+10 | |||
Minimum of Months | 0.00 | 0.00 | -13.3 | |
Maximum of Months | 0.524379E+09 | 1435.11 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 705231.24 | 324.70 | 15-JAN-11:25 | 7.50 |
February | 487323.57 | 319.48 | 19-FEB-09:45 | 6.23 |
March | 3110423.80 | 276.94 | 20-MAR-15:07 | 6.20 |
April | 2086952.66 | 360.31 | 02-APR-08:59 | 6.70 |
May | 412922.00 | 99.17 | 02-MAY-03:50 | 8.30 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 841154.61 | 217.41 | 29-OCT-07:41 | 5.95 |
November | 4838676.73 | 331.28 | 27-NOV-07:15 | 7.40 |
December | 2058553.31 | 361.96 | 25-DEC-05:45 | 8.22 |
Annual Sum or Average | 14541237.92 | |||
Minimum of Months | 0.00 | 0.00 | 5.95 | |
Maximum of Months | 4838676.73 | 361.96 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.115763E+09 | 616.01 | 02-JAN-04:50 | -12.1 |
February | 0.135161E+09 | 579.70 | 06-FEB-05:00 | -13.3 |
March | 9237302.18 | 429.27 | 12-MAR-08:40 | 7.07 |
April | 5494087.02 | 439.12 | 02-APR-08:59 | 6.70 |
May | 1705056.88 | 284.92 | 02-MAY-03:55 | 8.30 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 3043116.66 | 390.86 | 27-OCT-22:30 | 7.20 |
November | 11634518.03 | 448.58 | 07-NOV-00:43 | 7.20 |
December | 6088142.83 | 453.20 | 17-DEC-09:12 | 6.50 |
Annual Sum or Average | 0.288126E+09 | |||
Minimum of Months | 0.00 | 0.00 | -13.3 | |
Maximum of Months | 0.135161E+09 | 616.01 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.223987E+09 | 478.83 | 02-JAN-05:00 | -12.2 |
February | 0.213874E+09 | 466.67 | 06-FEB-10:05 | -11.0 |
March | 14369588.52 | 217.86 | 26-MAR-06:20 | 6.87 |
April | 3183569.94 | 227.13 | 20-APR-06:19 | 6.70 |
May | 953954.77 | 151.64 | 02-MAY-00:33 | 8.90 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 1818397.46 | 217.54 | 27-OCT-22:30 | 7.20 |
November | 20676463.97 | 653.53 | 30-NOV-13:53 | 6.70 |
December | 39001137.92 | 245.61 | 31-DEC-18:00 | -5.0 |
Annual Sum or Average | 0.517864E+09 | |||
Minimum of Months | 0.00 | 0.00 | -12.2 | |
Maximum of Months | 0.223987E+09 | 653.53 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -9.6 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -1.1 |
March | 775170.67 | 2337.54 | 27-MAR-03:06 | 8.22 |
April | 583845.65 | 2489.67 | 11-APR-02:06 | 8.03 |
May | 571141.33 | 2423.82 | 15-MAY-02:38 | 7.57 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 890586.50 | 3199.48 | 16-OCT-03:24 | 8.60 |
November | 2772866.14 | 3147.86 | 02-NOV-03:30 | 7.50 |
December | 271993.46 | 1820.22 | 05-DEC-02:14 | 7.80 |
Annual Sum or Average | 5865603.74 | |||
Minimum of Months | 0.00 | 0.00 | -9.6 | |
Maximum of Months | 2772866.14 | 3199.48 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 8961524.73 | 2162.95 | 22-JAN-19:46 | 6.10 |
February | 906714.71 | 1378.56 | 16-FEB-16:25 | 6.95 |
March | 11466268.57 | 2053.95 | 06-MAR-07:10 | 8.58 |
April | 11205370.96 | 2346.75 | 20-APR-06:19 | 6.70 |
May | 563288.15 | 1214.03 | 01-MAY-06:30 | 8.60 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 3454959.93 | 1680.46 | 27-OCT-06:55 | 6.10 |
November | 19024754.84 | 2794.02 | 13-NOV-08:23 | 6.40 |
December | 6698770.01 | 2113.03 | 26-DEC-07:58 | 6.70 |
Annual Sum or Average | 62281651.89 | |||
Minimum of Months | 0.00 | 0.00 | 6.10 | |
Maximum of Months | 19024754.84 | 2794.02 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3716546.86 | 4992.73 | 15-JAN-11:25 | 7.50 |
February | 4165410.90 | 4127.90 | 16-FEB-16:25 | 6.95 |
March | 18747621.34 | 3613.57 | 25-MAR-14:35 | 7.20 |
April | 13459305.97 | 4900.64 | 02-APR-08:59 | 6.70 |
May | 59778.20 | 293.25 | 01-MAY-06:30 | 8.60 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 4042724.34 | 4987.23 | 27-OCT-22:30 | 7.20 |
November | 25380805.99 | 5051.70 | 13-NOV-08:23 | 6.40 |
December | 15204371.13 | 4293.77 | 25-DEC-05:45 | 8.22 |
Annual Sum or Average | 84776564.72 | |||
Minimum of Months | 0.00 | 0.00 | 6.40 | |
Maximum of Months | 25380805.99 | 5051.70 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.129752E+10 | 2690.73 | 02-JAN-09:01 | -10.3 |
February | 0.106096E+10 | 2697.70 | 06-FEB-19:01 | -8.2 |
March | 0.467797E+09 | 2622.87 | 17-MAR-08:61 | -1.1 |
April | 0.187960E+09 | 2533.08 | 01-APR-08:61 | 5.18 |
May | 6913881.28 | 795.33 | 29-MAY-08:04 | 24.27 |
June | 655134.68 | 752.75 | 22-JUN-08:04 | 24.60 |
July | 588495.37 | 471.35 | 27-JUL-08:05 | 24.60 |
August | 618735.52 | 471.68 | 06-AUG-08:05 | 22.12 |
September | 1185589.48 | 660.13 | 23-SEP-08:04 | 13.30 |
October | 26329214.97 | 1424.25 | 27-OCT-08:61 | 7.48 |
November | 0.544234E+09 | 2615.45 | 25-NOV-09:01 | -0.3 |
December | 0.100902E+10 | 2667.66 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.460377E+10 | |||
Minimum of Months | 588495.37 | 471.35 | -10.3 | |
Maximum of Months | 0.129752E+10 | 2697.70 | 24.60 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.154973E+10 | 2706.49 | 02-JAN-09:01 | -10.3 |
February | 0.137369E+10 | 2711.08 | 06-FEB-09:01 | -12.0 |
March | 0.615379E+09 | 2618.29 | 22-MAR-08:61 | -2.0 |
April | 0.222861E+09 | 2532.84 | 03-APR-08:61 | 5.68 |
May | 7827004.72 | 767.52 | 30-MAY-08:04 | 25.18 |
June | 664248.71 | 796.33 | 04-JUN-08:04 | 22.38 |
July | 516645.33 | 522.01 | 27-JUL-08:05 | 24.60 |
August | 686028.83 | 510.30 | 10-AUG-08:05 | 24.18 |
September | 1763165.20 | 733.73 | 23-SEP-15:04 | 16.60 |
October | 59426497.20 | 2527.64 | 27-OCT-08:61 | 7.48 |
November | 0.715527E+09 | 2631.32 | 24-NOV-09:01 | -1.5 |
December | 0.127456E+10 | 2668.65 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.582262E+10 | |||
Minimum of Months | 516645.33 | 510.30 | -12.0 | |
Maximum of Months | 0.154973E+10 | 2711.08 | 25.18 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 83582087.97 | 253.20 | 02-JAN-05:00 | -12.2 |
February | 24889693.23 | 205.24 | 07-FEB-06:00 | -9.4 |
March | 2536155.22 | 107.42 | 01-MAR-06:00 | 3.90 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.27 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 10.33 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 12.47 |
November | 743629.93 | 53.99 | 29-NOV-05:00 | 3.90 |
December | 30948524.69 | 183.58 | 31-DEC-06:00 | -1.7 |
Annual Sum or Average | 0.142700E+09 | |||
Minimum of Months | 0.00 | 0.00 | -12.2 | |
Maximum of Months | 83582087.97 | 253.20 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.235750E+09 | 792.96 | 02-JAN-16:01 | -6.0 |
February | 0.234877E+09 | 794.16 | 06-FEB-16:01 | -7.1 |
March | 52742906.16 | 759.21 | 16-MAR-15:01 | 0.68 |
April | 3582236.93 | 721.78 | 03-APR-08:61 | 5.68 |
May | 611998.84 | 405.50 | 03-MAY-15:07 | 15.92 |
June | 100248.94 | 169.14 | 20-JUN-08:07 | 25.28 |
July | 49202.84 | 93.17 | 14-JUL-08:07 | 27.98 |
August | 120747.76 | 184.78 | 30-AUG-08:05 | 22.30 |
September | 330765.23 | 245.56 | 24-SEP-15:05 | 17.70 |
October | 1220545.33 | 465.02 | 21-OCT-18:03 | 17.12 |
November | 58246714.86 | 763.39 | 24-NOV-16:01 | 1.20 |
December | 0.155163E+09 | 777.49 | 31-DEC-16:01 | -3.1 |
Annual Sum or Average | 0.742796E+09 | |||
Minimum of Months | 49202.84 | 93.17 | -7.1 | |
Maximum of Months | 0.235750E+09 | 794.16 | 27.98 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.128701E+10 | 2632.94 | 14-JAN-16:02 | -6.1 |
February | 0.103410E+10 | 2631.83 | 06-FEB-19:01 | -8.2 |
March | 0.498015E+09 | 2563.80 | 17-MAR-08:61 | -1.1 |
April | 0.191092E+09 | 2479.01 | 21-APR-15:01 | 7.30 |
May | 7273324.44 | 700.64 | 05-MAY-15:04 | 18.12 |
June | 334913.29 | 408.32 | 17-JUN-08:05 | 20.68 |
July | 155635.07 | 455.02 | 31-JUL-08:05 | 25.68 |
August | 45595.37 | 296.37 | 06-AUG-18:05 | 20.00 |
September | 987323.15 | 641.89 | 23-SEP-08:04 | 13.30 |
October | 28399682.31 | 837.94 | 31-OCT-15:02 | 13.30 |
November | 0.510249E+09 | 2559.78 | 30-NOV-19:01 | 5.00 |
December | 0.995587E+09 | 2614.10 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.455325E+10 | |||
Minimum of Months | 45595.37 | 296.37 | -8.2 | |
Maximum of Months | 0.128701E+10 | 2632.94 | 25.68 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.153050E+10 | 2639.35 | 02-JAN-16:01 | -6.0 |
February | 0.133357E+10 | 2636.98 | 06-FEB-16:01 | -7.1 |
March | 0.648117E+09 | 2557.08 | 17-MAR-08:61 | -1.1 |
April | 0.224405E+09 | 2476.65 | 01-APR-15:01 | 6.28 |
May | 8334929.85 | 690.35 | 04-MAY-08:63 | 11.20 |
June | 219425.82 | 416.80 | 17-JUN-08:05 | 20.68 |
July | 125313.21 | 403.65 | 31-JUL-08:05 | 25.68 |
August | 33884.19 | 278.15 | 06-AUG-18:05 | 20.00 |
September | 1059005.87 | 629.15 | 23-SEP-15:04 | 16.60 |
October | 60941812.48 | 1706.27 | 31-OCT-15:02 | 13.30 |
November | 0.653353E+09 | 2563.46 | 30-NOV-19:01 | 5.00 |
December | 0.123463E+10 | 2613.95 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.569530E+10 | |||
Minimum of Months | 33884.19 | 278.15 | -7.1 | |
Maximum of Months | 0.153050E+10 | 2639.35 | 25.68 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 81147408.39 | 816.55 | 14-JAN-16:30 | -6.1 |
February | 38135638.15 | 698.83 | 20-FEB-09:39 | 6.67 |
March | 14556021.78 | 701.10 | 26-MAR-06:20 | 6.87 |
April | 8623225.81 | 712.80 | 20-APR-06:19 | 6.70 |
May | 2487384.03 | 428.62 | 02-MAY-03:55 | 8.30 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 4239777.19 | 607.78 | 27-OCT-22:30 | 7.20 |
November | 19124037.29 | 1426.81 | 30-NOV-13:53 | 6.70 |
December | 27244627.04 | 719.15 | 25-DEC-05:45 | 8.22 |
Annual Sum or Average | 0.195558E+09 | |||
Minimum of Months | 0.00 | 0.00 | -6.1 | |
Maximum of Months | 81147408.39 | 1426.81 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.183249E+10 | 3152.23 | 02-JAN-09:01 | -10.3 |
February | 0.153174E+10 | 3160.19 | 06-FEB-19:01 | -8.2 |
March | 0.752082E+09 | 3056.54 | 17-MAR-08:61 | -1.1 |
April | 0.341097E+09 | 2974.88 | 01-APR-08:61 | 5.18 |
May | 27940851.22 | 1274.85 | 01-MAY-08:62 | 12.48 |
June | 648598.07 | 750.53 | 26-JUN-08:04 | 24.08 |
July | 702127.05 | 532.98 | 01-JUL-08:04 | 24.18 |
August | 617605.32 | 483.79 | 27-AUG-08:05 | 23.07 |
September | 4079250.81 | 910.04 | 23-SEP-15:04 | 16.60 |
October | 92810020.04 | 2952.58 | 27-OCT-08:61 | 7.48 |
November | 0.861578E+09 | 3061.79 | 30-NOV-19:01 | 5.00 |
December | 0.147776E+10 | 3116.80 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.692354E+10 | |||
Minimum of Months | 617605.32 | 483.79 | -10.3 | |
Maximum of Months | 0.183249E+10 | 3160.19 | 24.18 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.213937E+10 | 3164.22 | 02-JAN-09:01 | -10.3 |
February | 0.190746E+10 | 3170.45 | 06-FEB-09:01 | -12.0 |
March | 0.946777E+09 | 3052.92 | 22-MAR-08:61 | -2.0 |
April | 0.394903E+09 | 2970.74 | 03-APR-08:61 | 5.68 |
May | 30558605.14 | 1444.52 | 01-MAY-08:62 | 12.48 |
June | 680086.15 | 739.19 | 22-JUN-08:04 | 24.60 |
July | 663819.62 | 532.00 | 28-JUL-08:05 | 23.80 |
August | 658592.54 | 482.27 | 27-AUG-08:05 | 23.07 |
September | 5386667.41 | 916.15 | 23-SEP-15:04 | 16.60 |
October | 0.170547E+09 | 2991.62 | 27-OCT-08:61 | 7.48 |
November | 0.110095E+10 | 3064.63 | 24-NOV-09:01 | -1.5 |
December | 0.180907E+10 | 3120.98 | 31-DEC-19:01 | -5.7 |
Annual Sum or Average | 0.850702E+10 | |||
Minimum of Months | 658592.54 | 482.27 | -12.0 | |
Maximum of Months | 0.213937E+10 | 3170.45 | 24.60 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.572067E+09 | 1647.11 | 14-JAN-16:02 | -6.1 |
February | 0.409078E+09 | 1629.63 | 06-FEB-19:01 | -8.2 |
March | 0.198072E+09 | 1600.22 | 17-MAR-08:61 | -1.1 |
April | 87793929.12 | 1546.92 | 21-APR-15:01 | 7.30 |
May | 3091594.66 | 399.20 | 03-MAY-15:07 | 15.92 |
June | 403503.69 | 528.94 | 22-JUN-08:04 | 24.60 |
July | 431844.78 | 375.53 | 12-JUL-08:05 | 26.28 |
August | 355965.21 | 365.12 | 01-AUG-08:05 | 26.97 |
September | 319546.01 | 418.73 | 23-SEP-08:04 | 13.30 |
October | 5386248.34 | 521.22 | 27-OCT-18:03 | 8.80 |
November | 0.173188E+09 | 1571.64 | 25-NOV-09:01 | -0.3 |
December | 0.402527E+09 | 1603.88 | 11-DEC-16:01 | 1.10 |
Annual Sum or Average | 0.185271E+10 | |||
Minimum of Months | 319546.01 | 365.12 | -8.2 | |
Maximum of Months | 0.572067E+09 | 1647.11 | 26.97 |
Report: ZoneHeatingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -9.6 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -1.1 |
March | 43048.55 | 274.57 | 02-MAR-08:34 | 7.03 |
April | 20119.02 | 335.32 | 20-APR-06:19 | 6.70 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 10.33 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 118577.97 | 555.18 | 27-OCT-21:47 | 7.20 |
November | 24691.08 | 411.52 | 13-NOV-08:23 | 6.40 |
December | 27899.77 | 260.52 | 17-DEC-09:12 | 6.50 |
Annual Sum or Average | 234336.39 | |||
Minimum of Months | 0.00 | 0.00 | -9.6 | |
Maximum of Months | 118577.97 | 555.18 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -9.6 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -1.1 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 5.52 |
April | 8676.60 | 144.61 | 20-APR-06:19 | 6.70 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 10.33 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 78427.70 | 468.89 | 27-OCT-21:47 | 7.20 |
November | 11754.25 | 195.90 | 13-NOV-08:23 | 6.40 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 5.97 |
Annual Sum or Average | 98858.56 | |||
Minimum of Months | 0.00 | 0.00 | -9.6 | |
Maximum of Months | 78427.70 | 468.89 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -9.6 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -1.1 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 5.52 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.27 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 10.33 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 23.43 |
October | 22463.35 | 374.39 | 18-OCT-01:46 | 7.80 |
November | 2333.97 | 38.90 | 02-NOV-02:26 | 8.05 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 5.97 |
Annual Sum or Average | 24797.32 | |||
Minimum of Months | 0.00 | 0.00 | -9.6 | |
Maximum of Months | 22463.35 | 374.39 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.467220E+09 | 2523.12 | 02-JAN-07:10 | -11.6 |
February | 0.363164E+09 | 2462.73 | 06-FEB-07:10 | -13.2 |
March | 33420685.44 | 1488.78 | 26-MAR-06:20 | 6.87 |
April | 19984310.94 | 1574.28 | 20-APR-06:19 | 6.70 |
May | 6193781.55 | 994.89 | 02-MAY-04:13 | 8.30 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 23.90 |
September | 255.97 | 3.41 | 24-SEP-05:16 | 10.40 |
October | 13444869.63 | 1518.03 | 27-OCT-22:30 | 7.20 |
November | 62109063.29 | 1617.10 | 07-NOV-00:43 | 7.20 |
December | 44533376.20 | 1500.23 | 25-DEC-22:44 | 6.70 |
Annual Sum or Average | 0.101007E+10 | |||
Minimum of Months | 0.00 | 0.00 | -13.2 | |
Maximum of Months | 0.467220E+09 | 2523.12 | 23.90 |
Report: ZoneElectricSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.147273E+11 | 14185.34 | 02-JAN-20:10 | 0.127587E+11 | 10113.80 | 02-JAN-20:10 |
February | 0.132974E+11 | 14185.34 | 01-FEB-20:10 | 0.115208E+11 | 10113.80 | 01-FEB-20:10 |
March | 0.147727E+11 | 14185.34 | 01-MAR-20:10 | 0.127855E+11 | 10113.80 | 01-MAR-20:10 |
April | 0.142280E+11 | 14185.34 | 03-APR-19:10 | 0.123314E+11 | 10113.80 | 03-APR-19:10 |
May | 0.147528E+11 | 14185.34 | 01-MAY-19:10 | 0.127741E+11 | 10113.80 | 01-MAY-19:10 |
June | 0.142932E+11 | 14185.34 | 01-JUN-19:10 | 0.123716E+11 | 10113.80 | 01-JUN-19:10 |
July | 0.146876E+11 | 14185.34 | 03-JUL-19:10 | 0.127338E+11 | 10113.80 | 03-JUL-19:10 |
August | 0.147784E+11 | 14185.34 | 01-AUG-19:10 | 0.127894E+11 | 10113.80 | 01-AUG-19:10 |
September | 0.142337E+11 | 14185.34 | 01-SEP-19:10 | 0.123352E+11 | 10113.80 | 01-SEP-19:10 |
October | 0.147216E+11 | 14185.34 | 02-OCT-19:10 | 0.127549E+11 | 10113.80 | 02-OCT-19:10 |
November | 0.142819E+11 | 14185.34 | 01-NOV-19:10 | 0.123659E+11 | 10113.80 | 01-NOV-19:10 |
December | 0.146876E+11 | 14185.34 | 01-DEC-20:10 | 0.127338E+11 | 10113.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.173462E+12 | 0.150255E+12 | ||||
Minimum of Months | 0.132974E+11 | 14185.34 | 0.115208E+11 | 10113.80 | ||
Maximum of Months | 0.147784E+11 | 14185.34 | 0.127894E+11 | 10113.80 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.731324E+09 | 704.41 | 02-JAN-20:10 | 0.864900E+09 | 685.60 | 02-JAN-20:10 |
February | 0.660319E+09 | 704.41 | 01-FEB-20:10 | 0.780982E+09 | 685.60 | 01-FEB-20:10 |
March | 0.733578E+09 | 704.41 | 01-MAR-20:10 | 0.866718E+09 | 685.60 | 01-MAR-20:10 |
April | 0.706528E+09 | 704.41 | 03-APR-19:10 | 0.835931E+09 | 685.60 | 03-APR-19:10 |
May | 0.732592E+09 | 704.41 | 01-MAY-19:10 | 0.865939E+09 | 685.60 | 01-MAY-19:10 |
June | 0.709769E+09 | 704.41 | 01-JUN-19:10 | 0.838659E+09 | 685.60 | 01-JUN-19:10 |
July | 0.729351E+09 | 704.41 | 03-JUL-19:10 | 0.863211E+09 | 685.60 | 03-JUL-19:10 |
August | 0.733860E+09 | 704.41 | 01-AUG-19:10 | 0.866978E+09 | 685.60 | 01-AUG-19:10 |
September | 0.706810E+09 | 704.41 | 01-SEP-19:10 | 0.836191E+09 | 685.60 | 01-SEP-19:10 |
October | 0.731042E+09 | 704.41 | 02-OCT-19:10 | 0.864640E+09 | 685.60 | 02-OCT-19:10 |
November | 0.709205E+09 | 704.41 | 01-NOV-19:10 | 0.838269E+09 | 685.60 | 01-NOV-19:10 |
December | 0.729351E+09 | 704.41 | 01-DEC-20:10 | 0.863211E+09 | 685.60 | 01-DEC-20:10 |
Annual Sum or Average | 0.861373E+10 | 0.101856E+11 | ||||
Minimum of Months | 0.660319E+09 | 704.41 | 0.780982E+09 | 685.60 | ||
Maximum of Months | 0.733860E+09 | 704.41 | 0.866978E+09 | 685.60 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.846876E+09 | 815.72 | 02-JAN-20:10 | 0.100156E+10 | 793.93 | 02-JAN-20:10 |
February | 0.764651E+09 | 815.72 | 01-FEB-20:10 | 0.904380E+09 | 793.93 | 01-FEB-20:10 |
March | 0.849486E+09 | 815.72 | 01-MAR-20:10 | 0.100366E+10 | 793.93 | 01-MAR-20:10 |
April | 0.818162E+09 | 815.72 | 03-APR-19:10 | 0.968011E+09 | 793.93 | 03-APR-19:10 |
May | 0.848344E+09 | 815.72 | 01-MAY-19:10 | 0.100276E+10 | 793.93 | 01-MAY-19:10 |
June | 0.821915E+09 | 815.72 | 01-JUN-19:10 | 0.971170E+09 | 793.93 | 01-JUN-19:10 |
July | 0.844592E+09 | 815.72 | 03-JUL-19:10 | 0.999601E+09 | 793.93 | 03-JUL-19:10 |
August | 0.849812E+09 | 815.72 | 01-AUG-19:10 | 0.100396E+10 | 793.93 | 01-AUG-19:10 |
September | 0.818489E+09 | 815.72 | 01-SEP-19:10 | 0.968312E+09 | 793.93 | 01-SEP-19:10 |
October | 0.846549E+09 | 815.72 | 02-OCT-19:10 | 0.100126E+10 | 793.93 | 02-OCT-19:10 |
November | 0.821262E+09 | 815.72 | 01-NOV-19:10 | 0.970719E+09 | 793.93 | 01-NOV-19:10 |
December | 0.844592E+09 | 815.72 | 01-DEC-20:10 | 0.999601E+09 | 793.93 | 01-DEC-20:10 |
Annual Sum or Average | 0.997473E+10 | 0.117950E+11 | ||||
Minimum of Months | 0.764651E+09 | 815.72 | 0.904380E+09 | 793.93 | ||
Maximum of Months | 0.849812E+09 | 815.72 | 0.100396E+10 | 793.93 |
Report: ZoneElectricSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.141236E+10 | 1360.40 | 02-JAN-20:10 | 0.105898E+10 | 839.45 | 02-JAN-20:10 |
February | 0.127524E+10 | 1360.40 | 01-FEB-20:10 | 0.956227E+09 | 839.45 | 01-FEB-20:10 |
March | 0.141672E+10 | 1360.40 | 01-MAR-20:10 | 0.106120E+10 | 839.45 | 01-MAR-20:10 |
April | 0.136448E+10 | 1360.40 | 03-APR-19:10 | 0.102351E+10 | 839.45 | 03-APR-19:10 |
May | 0.141481E+10 | 1360.40 | 01-MAY-19:10 | 0.106025E+10 | 839.45 | 01-MAY-19:10 |
June | 0.137074E+10 | 1360.40 | 01-JUN-19:10 | 0.102685E+10 | 839.45 | 01-JUN-19:10 |
July | 0.140855E+10 | 1360.40 | 03-JUL-19:10 | 0.105691E+10 | 839.45 | 03-JUL-19:10 |
August | 0.141726E+10 | 1360.40 | 01-AUG-19:10 | 0.106152E+10 | 839.45 | 01-AUG-19:10 |
September | 0.136502E+10 | 1360.40 | 01-SEP-19:10 | 0.102382E+10 | 839.45 | 01-SEP-19:10 |
October | 0.141182E+10 | 1360.40 | 02-OCT-19:10 | 0.105866E+10 | 839.45 | 02-OCT-19:10 |
November | 0.136965E+10 | 1360.40 | 01-NOV-19:10 | 0.102637E+10 | 839.45 | 01-NOV-19:10 |
December | 0.140855E+10 | 1360.40 | 01-DEC-20:10 | 0.105691E+10 | 839.45 | 01-DEC-20:10 |
Annual Sum or Average | 0.166352E+11 | 0.124712E+11 | ||||
Minimum of Months | 0.127524E+10 | 1360.40 | 0.956227E+09 | 839.45 | ||
Maximum of Months | 0.141726E+10 | 1360.40 | 0.106152E+10 | 839.45 |
Report: ZoneElectricSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.236418E+09 | 227.72 | 02-JAN-20:10 | 0.305485E+09 | 242.16 | 02-JAN-20:10 |
February | 0.213464E+09 | 227.72 | 01-FEB-20:10 | 0.275845E+09 | 242.16 | 01-FEB-20:10 |
March | 0.237147E+09 | 227.72 | 01-MAR-20:10 | 0.306128E+09 | 242.16 | 01-MAR-20:10 |
April | 0.228402E+09 | 227.72 | 03-APR-19:10 | 0.295253E+09 | 242.16 | 03-APR-19:10 |
May | 0.236828E+09 | 227.72 | 01-MAY-19:10 | 0.305852E+09 | 242.16 | 01-MAY-19:10 |
June | 0.229450E+09 | 227.72 | 01-JUN-19:10 | 0.296217E+09 | 242.16 | 01-JUN-19:10 |
July | 0.235780E+09 | 227.72 | 03-JUL-19:10 | 0.304889E+09 | 242.16 | 03-JUL-19:10 |
August | 0.237238E+09 | 227.72 | 01-AUG-19:10 | 0.306219E+09 | 242.16 | 01-AUG-19:10 |
September | 0.228493E+09 | 227.72 | 01-SEP-19:10 | 0.295345E+09 | 242.16 | 01-SEP-19:10 |
October | 0.236327E+09 | 227.72 | 02-OCT-19:10 | 0.305393E+09 | 242.16 | 02-OCT-19:10 |
November | 0.229268E+09 | 227.72 | 01-NOV-19:10 | 0.296079E+09 | 242.16 | 01-NOV-19:10 |
December | 0.235780E+09 | 227.72 | 01-DEC-20:10 | 0.304889E+09 | 242.16 | 01-DEC-20:10 |
Annual Sum or Average | 0.278459E+10 | 0.359760E+10 | ||||
Minimum of Months | 0.213464E+09 | 227.72 | 0.275845E+09 | 242.16 | ||
Maximum of Months | 0.237238E+09 | 227.72 | 0.306219E+09 | 242.16 |
Report: ZoneElectricSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.370859E+09 | 357.21 | 02-JAN-20:10 | 0.576866E+10 | 4572.80 | 02-JAN-20:10 |
February | 0.334852E+09 | 357.21 | 01-FEB-20:10 | 0.520895E+10 | 4572.80 | 01-FEB-20:10 |
March | 0.372002E+09 | 357.21 | 01-MAR-20:10 | 0.578079E+10 | 4572.80 | 01-MAR-20:10 |
April | 0.358285E+09 | 357.21 | 03-APR-19:10 | 0.557545E+10 | 4572.80 | 03-APR-19:10 |
May | 0.371502E+09 | 357.21 | 01-MAY-19:10 | 0.577559E+10 | 4572.80 | 01-MAY-19:10 |
June | 0.359929E+09 | 357.21 | 01-JUN-19:10 | 0.559364E+10 | 4572.80 | 01-JUN-19:10 |
July | 0.369859E+09 | 357.21 | 03-JUL-19:10 | 0.575740E+10 | 4572.80 | 03-JUL-19:10 |
August | 0.372145E+09 | 357.21 | 01-AUG-19:10 | 0.578252E+10 | 4572.80 | 01-AUG-19:10 |
September | 0.358428E+09 | 357.21 | 01-SEP-19:10 | 0.557718E+10 | 4572.80 | 01-SEP-19:10 |
October | 0.370717E+09 | 357.21 | 02-OCT-19:10 | 0.576693E+10 | 4572.80 | 02-OCT-19:10 |
November | 0.359643E+09 | 357.21 | 01-NOV-19:10 | 0.559104E+10 | 4572.80 | 01-NOV-19:10 |
December | 0.369859E+09 | 357.21 | 01-DEC-20:10 | 0.575740E+10 | 4572.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.436808E+10 | 0.679355E+11 | ||||
Minimum of Months | 0.334852E+09 | 357.21 | 0.520895E+10 | 4572.80 | ||
Maximum of Months | 0.372145E+09 | 357.21 | 0.578252E+10 | 4572.80 |
Report: ZoneElectricSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.161485E+10 | 1761.91 | 02-JAN-20:10 | 0.121771E+10 | 965.27 | 02-JAN-20:10 |
February | 0.142581E+10 | 1761.91 | 01-FEB-20:10 | 0.109956E+10 | 965.27 | 01-FEB-20:10 |
March | 0.154426E+10 | 1761.91 | 01-MAR-20:10 | 0.122027E+10 | 965.27 | 01-MAR-20:10 |
April | 0.144251E+10 | 1761.91 | 03-APR-19:10 | 0.117692E+10 | 965.27 | 03-APR-19:10 |
May | 0.143957E+10 | 1761.91 | 01-MAY-19:10 | 0.121917E+10 | 965.27 | 01-MAY-19:10 |
June | 0.137211E+10 | 1761.91 | 01-JUN-19:19 | 0.118076E+10 | 965.27 | 01-JUN-19:10 |
July | 0.141436E+10 | 1761.91 | 03-JUL-19:19 | 0.121533E+10 | 965.27 | 03-JUL-19:10 |
August | 0.147541E+10 | 1761.91 | 01-AUG-19:10 | 0.122063E+10 | 965.27 | 01-AUG-19:10 |
September | 0.147004E+10 | 1761.91 | 01-SEP-19:10 | 0.117729E+10 | 965.27 | 01-SEP-19:10 |
October | 0.157141E+10 | 1761.91 | 02-OCT-19:10 | 0.121734E+10 | 965.27 | 02-OCT-19:10 |
November | 0.154685E+10 | 1761.91 | 01-NOV-19:10 | 0.118021E+10 | 965.27 | 01-NOV-19:10 |
December | 0.160913E+10 | 1761.91 | 01-DEC-20:10 | 0.121533E+10 | 965.27 | 01-DEC-20:10 |
Annual Sum or Average | 0.179263E+11 | 0.143405E+11 | ||||
Minimum of Months | 0.137211E+10 | 1761.91 | 0.109956E+10 | 965.27 | ||
Maximum of Months | 0.161485E+10 | 1761.91 | 0.122063E+10 | 965.27 |
Report: ZoneElectricSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.104401E+11 | 10265.18 | 02-JAN-20:10 | 0.126520E+11 | 10029.21 | 02-JAN-20:10 |
February | 0.939242E+10 | 10265.18 | 01-FEB-20:10 | 0.114244E+11 | 10029.21 | 01-FEB-20:10 |
March | 0.103944E+11 | 10265.18 | 01-MAR-20:10 | 0.126786E+11 | 10029.21 | 01-MAR-20:10 |
April | 0.996917E+10 | 10265.18 | 03-APR-19:10 | 0.122282E+11 | 10029.21 | 03-APR-19:10 |
May | 0.102791E+11 | 10265.18 | 01-MAY-19:10 | 0.126672E+11 | 10029.21 | 01-MAY-19:10 |
June | 0.993906E+10 | 10265.18 | 01-JUN-19:10 | 0.122682E+11 | 10029.21 | 01-JUN-19:10 |
July | 0.102179E+11 | 10265.18 | 03-JUL-19:19 | 0.126273E+11 | 10029.21 | 03-JUL-19:10 |
August | 0.103290E+11 | 10265.18 | 01-AUG-19:10 | 0.126824E+11 | 10029.21 | 01-AUG-19:10 |
September | 0.999889E+10 | 10265.18 | 01-SEP-19:10 | 0.122320E+11 | 10029.21 | 01-SEP-19:10 |
October | 0.103905E+11 | 10265.18 | 02-OCT-19:10 | 0.126482E+11 | 10029.21 | 02-OCT-19:10 |
November | 0.101030E+11 | 10265.18 | 01-NOV-19:10 | 0.122624E+11 | 10029.21 | 01-NOV-19:10 |
December | 0.104094E+11 | 10265.18 | 01-DEC-20:10 | 0.126273E+11 | 10029.21 | 01-DEC-20:10 |
Annual Sum or Average | 0.121863E+12 | 0.148998E+12 | ||||
Minimum of Months | 0.939242E+10 | 10265.18 | 0.114244E+11 | 10029.21 | ||
Maximum of Months | 0.104401E+11 | 10265.18 | 0.126824E+11 | 10029.21 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135397E+09 | 122.50 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.122277E+09 | 122.50 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.134321E+09 | 122.50 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.131185E+09 | 122.50 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.134859E+09 | 122.50 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.130145E+09 | 122.50 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.135918E+09 | 122.50 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.134321E+09 | 122.50 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.131221E+09 | 122.50 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.135380E+09 | 122.50 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.130665E+09 | 122.50 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.135935E+09 | 122.50 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.159162E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.122277E+09 | 122.50 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.135935E+09 | 122.50 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135381E+09 | 122.49 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.122263E+09 | 122.49 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.134305E+09 | 122.49 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.131170E+09 | 122.49 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.134843E+09 | 122.49 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.130129E+09 | 122.49 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.135902E+09 | 122.49 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.134305E+09 | 122.49 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.131205E+09 | 122.49 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.135364E+09 | 122.49 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.130650E+09 | 122.49 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.135919E+09 | 122.49 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.159144E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.122263E+09 | 122.49 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.135919E+09 | 122.49 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 85091918.49 | 76.99 | 01-JAN-19:10 | 0.255708E+09 | 232.19 | 01-JAN-08:09 |
February | 76846309.13 | 76.99 | 01-FEB-20:10 | 0.230956E+09 | 232.19 | 01-FEB-07:10 |
March | 84415649.14 | 76.99 | 01-MAR-20:10 | 0.255355E+09 | 232.19 | 01-MAR-07:10 |
April | 82445007.08 | 76.99 | 01-APR-18:10 | 0.247516E+09 | 232.19 | 01-APR-07:10 |
May | 84753783.81 | 76.99 | 01-MAY-19:10 | 0.255532E+09 | 232.19 | 01-MAY-06:10 |
June | 81790910.76 | 76.99 | 01-JUN-19:10 | 0.247163E+09 | 232.19 | 01-JUN-06:10 |
July | 85418966.65 | 76.99 | 01-JUL-18:10 | 0.255885E+09 | 232.19 | 01-JUL-07:10 |
August | 84415649.14 | 76.99 | 01-AUG-19:10 | 0.255355E+09 | 232.19 | 01-AUG-06:10 |
September | 82467180.11 | 76.99 | 01-SEP-19:10 | 0.247516E+09 | 232.19 | 01-SEP-06:10 |
October | 85080831.98 | 76.99 | 01-OCT-18:10 | 0.255708E+09 | 232.19 | 01-OCT-07:10 |
November | 82117958.92 | 76.99 | 01-NOV-19:10 | 0.247340E+09 | 232.19 | 01-NOV-06:10 |
December | 85430053.17 | 76.99 | 01-DEC-20:10 | 0.255885E+09 | 232.19 | 01-DEC-07:10 |
Annual Sum or Average | 0.100027E+10 | 0.300992E+10 | ||||
Minimum of Months | 76846309.13 | 76.99 | 0.230956E+09 | 232.19 | ||
Maximum of Months | 85430053.17 | 76.99 | 0.255885E+09 | 232.19 |
Report: ZoneElectricSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 85115186.72 | 77.01 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 76867322.62 | 77.01 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 84438732.44 | 77.01 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 82467551.52 | 77.01 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 84776959.58 | 77.01 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 81813276.33 | 77.01 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 85442324.32 | 77.01 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 84438732.44 | 77.01 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 82489730.61 | 77.01 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 85104097.18 | 77.01 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 82140413.93 | 77.01 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 85453413.86 | 77.01 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.100055E+10 | 0.301074E+10 | ||||
Minimum of Months | 76867322.62 | 77.01 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 85453413.86 | 77.01 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135397E+09 | 122.50 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.122277E+09 | 122.50 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.134321E+09 | 122.50 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.131185E+09 | 122.50 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.134859E+09 | 122.50 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.130145E+09 | 122.50 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.135918E+09 | 122.50 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.134321E+09 | 122.50 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.131221E+09 | 122.50 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.135380E+09 | 122.50 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.130665E+09 | 122.50 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.135935E+09 | 122.50 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.159162E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.122277E+09 | 122.50 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.135935E+09 | 122.50 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135381E+09 | 122.49 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.122263E+09 | 122.49 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.134305E+09 | 122.49 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.131170E+09 | 122.49 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.134843E+09 | 122.49 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.130129E+09 | 122.49 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.135902E+09 | 122.49 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.134305E+09 | 122.49 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.131205E+09 | 122.49 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.135364E+09 | 122.49 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.130650E+09 | 122.49 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.135919E+09 | 122.49 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.159144E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.122263E+09 | 122.49 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.135919E+09 | 122.49 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.232638E+10 | 2240.78 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.210051E+10 | 2240.78 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.233355E+10 | 2240.78 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.224750E+10 | 2240.78 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.233041E+10 | 2240.78 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.225781E+10 | 2240.78 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.232011E+10 | 2240.78 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.233445E+10 | 2240.78 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.224840E+10 | 2240.78 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.232548E+10 | 2240.78 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.225602E+10 | 2240.78 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.232011E+10 | 2240.78 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.274007E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.210051E+10 | 2240.78 | 0.00 | 0.00 | |
Maximum of Months | 0.233445E+10 | 2240.78 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135397E+09 | 122.50 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.122277E+09 | 122.50 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.134321E+09 | 122.50 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.131185E+09 | 122.50 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.134859E+09 | 122.50 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.130145E+09 | 122.50 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.135918E+09 | 122.50 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.134321E+09 | 122.50 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.131221E+09 | 122.50 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.135380E+09 | 122.50 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.130665E+09 | 122.50 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.135935E+09 | 122.50 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.159162E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.122277E+09 | 122.50 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.135935E+09 | 122.50 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.135381E+09 | 122.49 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.122263E+09 | 122.49 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.134305E+09 | 122.49 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.131170E+09 | 122.49 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.134843E+09 | 122.49 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.130129E+09 | 122.49 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.135902E+09 | 122.49 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.134305E+09 | 122.49 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.131205E+09 | 122.49 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.135364E+09 | 122.49 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.130650E+09 | 122.49 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.135919E+09 | 122.49 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.159144E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.122263E+09 | 122.49 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.135919E+09 | 122.49 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 85115186.72 | 77.01 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 76867322.62 | 77.01 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 84438732.44 | 77.01 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 82467551.52 | 77.01 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 84776959.58 | 77.01 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 81813276.33 | 77.01 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 85442324.32 | 77.01 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 84438732.44 | 77.01 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 82489730.61 | 77.01 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 85104097.18 | 77.01 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 82140413.93 | 77.01 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 85453413.86 | 77.01 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.100055E+10 | 0.301074E+10 | ||||
Minimum of Months | 76867322.62 | 77.01 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 85453413.86 | 77.01 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.303429E+10 | 3094.06 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.270887E+10 | 3094.06 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.296851E+10 | 3094.06 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.281177E+10 | 3094.06 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.285834E+10 | 3094.06 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.274883E+10 | 3094.06 | 01-JUN-19:19 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.282901E+10 | 3094.06 | 03-JUL-19:30 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.289613E+10 | 3094.06 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.284038E+10 | 3094.06 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.298860E+10 | 3094.06 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.292070E+10 | 3094.06 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.302980E+10 | 3094.06 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.346352E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.270887E+10 | 3094.06 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.303429E+10 | 3094.06 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.303429E+10 | 3094.06 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.270887E+10 | 3094.06 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.296851E+10 | 3094.06 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.281177E+10 | 3094.06 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.285834E+10 | 3094.06 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.274883E+10 | 3094.06 | 01-JUN-19:19 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.282901E+10 | 3094.06 | 03-JUL-19:30 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.289613E+10 | 3094.06 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.284038E+10 | 3094.06 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.298860E+10 | 3094.06 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.292070E+10 | 3094.06 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.302980E+10 | 3094.06 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.346352E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.270887E+10 | 3094.06 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.303429E+10 | 3094.06 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.113146E+10 | 1089.83 | 02-JAN-20:10 | 0.368383E+11 | 16487.34 | 01-JAN-07:10 |
February | 0.102161E+10 | 1089.83 | 01-FEB-20:10 | 0.332733E+11 | 16487.34 | 01-FEB-07:10 |
March | 0.113495E+10 | 1089.83 | 01-MAR-20:10 | 0.368383E+11 | 16487.34 | 01-MAR-07:10 |
April | 0.109310E+10 | 1089.83 | 03-APR-19:10 | 0.356500E+11 | 16487.34 | 01-APR-06:10 |
May | 0.113342E+10 | 1089.83 | 01-MAY-19:10 | 0.368383E+11 | 16487.34 | 01-MAY-06:10 |
June | 0.109811E+10 | 1089.83 | 01-JUN-19:10 | 0.356500E+11 | 16487.34 | 01-JUN-06:10 |
July | 0.112841E+10 | 1089.83 | 03-JUL-19:10 | 0.368383E+11 | 16487.34 | 01-JUL-06:10 |
August | 0.113539E+10 | 1089.83 | 01-AUG-19:10 | 0.368383E+11 | 16487.34 | 01-AUG-06:10 |
September | 0.109354E+10 | 1089.83 | 01-SEP-19:10 | 0.356500E+11 | 16487.34 | 01-SEP-06:10 |
October | 0.113103E+10 | 1089.83 | 02-OCT-19:10 | 0.368383E+11 | 16487.34 | 01-OCT-06:10 |
November | 0.109724E+10 | 1089.83 | 01-NOV-19:10 | 0.356500E+11 | 16487.34 | 01-NOV-06:10 |
December | 0.112841E+10 | 1089.83 | 01-DEC-20:10 | 0.368383E+11 | 16487.34 | 01-DEC-07:10 |
Annual Sum or Average | 0.133267E+11 | 0.433742E+12 | ||||
Minimum of Months | 0.102161E+10 | 1089.83 | 0.332733E+11 | 16487.34 | ||
Maximum of Months | 0.113539E+10 | 1089.83 | 0.368383E+11 | 16487.34 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.246211E+10 | 2371.52 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.222306E+10 | 2371.52 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.246970E+10 | 2371.52 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.237864E+10 | 2371.52 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.246638E+10 | 2371.52 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.238954E+10 | 2371.52 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.245547E+10 | 2371.52 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.247065E+10 | 2371.52 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.237958E+10 | 2371.52 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.246116E+10 | 2371.52 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.238765E+10 | 2371.52 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.245547E+10 | 2371.52 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.289994E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.222306E+10 | 2371.52 | 0.00 | 0.00 | |
Maximum of Months | 0.247065E+10 | 2371.52 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.195762E+11 | 0.147273E+11 | 0.127587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176991E+11 | 0.132974E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.196682E+11 | 0.147727E+11 | 0.127855E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.189781E+11 | 0.142280E+11 | 0.123314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196176E+11 | 0.147528E+11 | 0.127741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.190195E+11 | 0.142932E+11 | 0.123716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.195762E+11 | 0.146876E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.196590E+11 | 0.147784E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.189689E+11 | 0.142337E+11 | 0.123352E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.195854E+11 | 0.147216E+11 | 0.127549E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.189367E+11 | 0.142819E+11 | 0.123659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.195762E+11 | 0.146876E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230861E+12 | 0.173462E+12 | 0.150255E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.176991E+11 | 0.132974E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.196682E+11 | 0.147784E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.199054E+10 | 0.731324E+09 | 0.864900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.689402E+09 |
February | 0.179968E+10 | 0.660319E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665242E+09 |
March | 0.199990E+10 | 0.733578E+09 | 0.866718E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.535681E+09 |
April | 0.192973E+10 | 0.706528E+09 | 0.835931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 611204.45 | 0.341400E+09 |
May | 0.199475E+10 | 0.732592E+09 | 0.865939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4508869.53 | 0.191057E+09 |
June | 0.193394E+10 | 0.709769E+09 | 0.838659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25876377.51 | 53538936.08 |
July | 0.199054E+10 | 0.729351E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 67975699.52 | 6460497.32 |
August | 0.199896E+10 | 0.733860E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 66811184.94 | 21318761.41 |
September | 0.192879E+10 | 0.706810E+09 | 0.836191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10517506.68 | 93659730.75 |
October | 0.199148E+10 | 0.731042E+09 | 0.864640E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 143964.63 | 0.275496E+09 |
November | 0.192552E+10 | 0.709205E+09 | 0.838269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456562E+09 |
December | 0.199054E+10 | 0.729351E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604635E+09 |
Annual Sum or Average | 0.234744E+11 | 0.861373E+10 | 0.101856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176445E+09 | 0.393445E+10 |
Minimum of Months | 0.179968E+10 | 0.660319E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6460497.32 |
Maximum of Months | 0.199990E+10 | 0.733860E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 67975699.52 | 0.689402E+09 |
Report: SpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.230505E+10 | 0.846876E+09 | 0.100156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.269416E+09 |
February | 0.208403E+10 | 0.764651E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259679E+09 |
March | 0.231589E+10 | 0.849486E+09 | 0.100366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215251E+09 |
April | 0.223463E+10 | 0.818162E+09 | 0.968011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 374617.67 | 0.142802E+09 |
May | 0.230993E+10 | 0.848344E+09 | 0.100276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1918671.39 | 88182552.67 |
June | 0.223950E+10 | 0.821915E+09 | 0.971170E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9551048.72 | 30785417.98 |
July | 0.230505E+10 | 0.844592E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23378286.06 | 6926702.68 |
August | 0.231480E+10 | 0.849812E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25046698.87 | 13029129.97 |
September | 0.223354E+10 | 0.818489E+09 | 0.968312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4147596.20 | 45940091.76 |
October | 0.230614E+10 | 0.846549E+09 | 0.100126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 148940.83 | 0.116350E+09 |
November | 0.222975E+10 | 0.821262E+09 | 0.970719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185200E+09 |
December | 0.230505E+10 | 0.844592E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238720E+09 |
Annual Sum or Average | 0.271834E+11 | 0.997473E+10 | 0.117950E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 64565859.75 | 0.161228E+10 |
Minimum of Months | 0.208403E+10 | 0.764651E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6926702.68 |
Maximum of Months | 0.231589E+10 | 0.849812E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25046698.87 | 0.269416E+09 |
Report: SpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.487480E+09 | 0.141236E+10 | 0.105898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.624708E+09 |
February | 0.440737E+09 | 0.127524E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.600028E+09 |
March | 0.489771E+09 | 0.141672E+10 | 0.106120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22733.11 | 0.482401E+09 |
April | 0.472586E+09 | 0.136448E+10 | 0.102351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1369055.40 | 0.314214E+09 |
May | 0.488511E+09 | 0.141481E+10 | 0.106025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4961028.96 | 0.193508E+09 |
June | 0.473617E+09 | 0.137074E+10 | 0.102685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22707994.88 | 68206681.37 |
July | 0.487480E+09 | 0.140855E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54432058.74 | 15002513.61 |
August | 0.489542E+09 | 0.141726E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59718362.81 | 28990251.64 |
September | 0.472357E+09 | 0.136502E+10 | 0.102382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10497314.44 | 0.101102E+09 |
October | 0.487709E+09 | 0.141182E+10 | 0.105866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 727716.94 | 0.252755E+09 |
November | 0.471555E+09 | 0.136965E+10 | 0.102637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.416952E+09 |
December | 0.487480E+09 | 0.140855E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.545361E+09 |
Annual Sum or Average | 0.574883E+10 | 0.166352E+11 | 0.124712E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154436E+09 | 0.364323E+10 |
Minimum of Months | 0.440737E+09 | 0.127524E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15002513.61 |
Maximum of Months | 0.489771E+09 | 0.141726E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59718362.81 | 0.624708E+09 |
Report: SpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.374985E+09 | 0.236418E+09 | 0.305485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359911E+09 |
February | 0.339028E+09 | 0.213464E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345791E+09 |
March | 0.376747E+09 | 0.237147E+09 | 0.306128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13228.14 | 0.276307E+09 |
April | 0.363528E+09 | 0.228402E+09 | 0.295253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 803959.94 | 0.178500E+09 |
May | 0.375778E+09 | 0.236828E+09 | 0.305852E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2945859.87 | 0.108322E+09 |
June | 0.364321E+09 | 0.229450E+09 | 0.296217E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13559435.85 | 37063487.93 |
July | 0.374985E+09 | 0.235780E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 32334677.67 | 7779560.04 |
August | 0.376571E+09 | 0.237238E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35104189.08 | 15731059.19 |
September | 0.363352E+09 | 0.228493E+09 | 0.295345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6341531.75 | 55804904.05 |
October | 0.375161E+09 | 0.236327E+09 | 0.305393E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 430181.28 | 0.142691E+09 |
November | 0.362735E+09 | 0.229268E+09 | 0.296079E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238177E+09 |
December | 0.374985E+09 | 0.235780E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313823E+09 |
Annual Sum or Average | 0.442217E+10 | 0.278459E+10 | 0.359760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91533063.58 | 0.207990E+10 |
Minimum of Months | 0.339028E+09 | 0.213464E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7779560.04 |
Maximum of Months | 0.376747E+09 | 0.237238E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35104189.08 | 0.359911E+09 |
Report: SpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.154405E+10 | 0.370859E+09 | 0.576866E+10 | 0.501157E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.927937E+09 |
February | 0.139600E+10 | 0.334852E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.887752E+09 |
March | 0.155131E+10 | 0.372002E+09 | 0.578079E+10 | 0.502211E+11 | 0.00 | 0.00 | 0.00 | 324.05 | 0.733307E+09 |
April | 0.149688E+10 | 0.358285E+09 | 0.557545E+10 | 0.484372E+11 | 0.00 | 0.00 | 0.00 | 1377803.14 | 0.483183E+09 |
May | 0.154732E+10 | 0.371502E+09 | 0.577559E+10 | 0.501759E+11 | 0.00 | 0.00 | 0.00 | 6982893.75 | 0.290281E+09 |
June | 0.150015E+10 | 0.359929E+09 | 0.559364E+10 | 0.485952E+11 | 0.00 | 0.00 | 0.00 | 36891669.60 | 88774759.43 |
July | 0.154405E+10 | 0.369859E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 93161946.32 | 15312082.99 |
August | 0.155059E+10 | 0.372145E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 99416422.93 | 32616559.27 |
September | 0.149615E+10 | 0.358428E+09 | 0.557718E+10 | 0.484522E+11 | 0.00 | 0.00 | 0.00 | 18971413.69 | 0.139571E+09 |
October | 0.154478E+10 | 0.370717E+09 | 0.576693E+10 | 0.501006E+11 | 0.00 | 0.00 | 0.00 | 955181.45 | 0.371213E+09 |
November | 0.149361E+10 | 0.359643E+09 | 0.559104E+10 | 0.485726E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.634184E+09 |
December | 0.154405E+10 | 0.369859E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.821220E+09 |
Annual Sum or Average | 0.182090E+11 | 0.436808E+10 | 0.679355E+11 | 0.590196E+12 | 0.00 | 0.00 | 0.00 | 0.257758E+09 | 0.542535E+10 |
Minimum of Months | 0.139600E+10 | 0.334852E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 15312082.99 |
Maximum of Months | 0.155131E+10 | 0.372145E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 99416422.93 | 0.927937E+09 |
Report: SpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.261570E+11 | 0.161485E+10 | 0.121771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155947E+10 |
February | 0.236489E+11 | 0.142581E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151059E+10 |
March | 0.262800E+11 | 0.154426E+10 | 0.122027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125168E+10 |
April | 0.253579E+11 | 0.144251E+10 | 0.117692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1211103.25 | 0.824081E+09 |
May | 0.262123E+11 | 0.143957E+10 | 0.121917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9026461.98 | 0.504043E+09 |
June | 0.254132E+11 | 0.137211E+10 | 0.118076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52012251.38 | 0.170135E+09 |
July | 0.261570E+11 | 0.141436E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133535E+09 | 37929728.20 |
August | 0.262677E+11 | 0.147541E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138495E+09 | 71704617.04 |
September | 0.253456E+11 | 0.147004E+10 | 0.117729E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21142544.59 | 0.265027E+09 |
October | 0.261693E+11 | 0.157141E+10 | 0.121734E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 322555.16 | 0.684931E+09 |
November | 0.253025E+11 | 0.154685E+10 | 0.118021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107447E+10 |
December | 0.261570E+11 | 0.160913E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138385E+10 |
Annual Sum or Average | 0.308468E+12 | 0.179263E+11 | 0.143405E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355744E+09 | 0.933792E+10 |
Minimum of Months | 0.236489E+11 | 0.137211E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37929728.20 |
Maximum of Months | 0.262800E+11 | 0.161485E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138495E+09 | 0.155947E+10 |
Report: SpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.776503E+11 | 0.104401E+11 | 0.126520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.454161E+10 |
February | 0.702046E+11 | 0.939242E+10 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437832E+10 |
March | 0.780153E+11 | 0.103944E+11 | 0.126786E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365835E+10 |
April | 0.752779E+11 | 0.996917E+10 | 0.122282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4612380.47 | 0.244255E+10 |
May | 0.778146E+11 | 0.102791E+11 | 0.126672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 28115041.37 | 0.152741E+10 |
June | 0.754422E+11 | 0.993906E+10 | 0.122682E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150074E+09 | 0.532119E+09 |
July | 0.776503E+11 | 0.102179E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.374129E+09 | 0.122745E+09 |
August | 0.779788E+11 | 0.103290E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.398652E+09 | 0.219767E+09 |
September | 0.752414E+11 | 0.999889E+10 | 0.122320E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 61192406.63 | 0.802832E+09 |
October | 0.776868E+11 | 0.103905E+11 | 0.126482E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1268255.62 | 0.199851E+10 |
November | 0.751137E+11 | 0.101030E+11 | 0.122624E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.316827E+10 |
December | 0.776503E+11 | 0.104094E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.405041E+10 |
Annual Sum or Average | 0.915726E+12 | 0.121863E+12 | 0.148998E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101804E+10 | 0.274429E+11 |
Minimum of Months | 0.702046E+11 | 0.939242E+10 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122745E+09 |
Maximum of Months | 0.780153E+11 | 0.104401E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.398652E+09 | 0.454161E+10 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135397E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392384E+09 |
February | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379535E+09 |
March | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17319.82 | 0.306157E+09 |
April | 0.293479E+09 | 0.131185E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 728020.09 | 0.195433E+09 |
May | 0.303504E+09 | 0.134859E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3793080.15 | 0.109365E+09 |
June | 0.293842E+09 | 0.130145E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22567870.78 | 23989137.92 |
July | 0.303141E+09 | 0.135918E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60483383.49 | 1214464.37 |
August | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60848171.44 | 6783669.56 |
September | 0.293479E+09 | 0.131221E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13000254.79 | 45384673.45 |
October | 0.303322E+09 | 0.135380E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 474363.63 | 0.146200E+09 |
November | 0.293661E+09 | 0.130665E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259599E+09 |
December | 0.303141E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343448E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159162E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161912E+09 | 0.220949E+10 |
Minimum of Months | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1214464.37 |
Maximum of Months | 0.303685E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60848171.44 | 0.392384E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135381E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388903E+09 |
February | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.375030E+09 |
March | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17346.15 | 0.301646E+09 |
April | 0.293479E+09 | 0.131170E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 787289.45 | 0.193350E+09 |
May | 0.303504E+09 | 0.134843E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3814533.40 | 0.108718E+09 |
June | 0.293842E+09 | 0.130129E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22608968.35 | 23909988.68 |
July | 0.303141E+09 | 0.135902E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60533303.55 | 1210012.26 |
August | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 61033650.20 | 6735773.14 |
September | 0.293479E+09 | 0.131205E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13160847.03 | 44499377.96 |
October | 0.303322E+09 | 0.135364E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 548050.98 | 0.142967E+09 |
November | 0.293661E+09 | 0.130650E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255409E+09 |
December | 0.303141E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338897E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159144E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162504E+09 | 0.218128E+10 |
Minimum of Months | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1210012.26 |
Maximum of Months | 0.303685E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 61033650.20 | 0.388903E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 85091918.49 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103784E+09 |
February | 0.00 | 76846309.13 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104003E+09 |
March | 0.00 | 84415649.14 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86632660.54 |
April | 0.00 | 82445007.08 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 122030.78 | 57606400.49 |
May | 0.00 | 84753783.81 | 0.255532E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 689783.21 | 36965031.84 |
June | 0.00 | 81790910.76 | 0.247163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3965840.74 | 11933957.23 |
July | 0.00 | 85418966.65 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10545904.78 | 2119898.45 |
August | 0.00 | 84415649.14 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11548446.44 | 4574850.87 |
September | 0.00 | 82467180.11 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1859007.88 | 18718252.60 |
October | 0.00 | 85080831.98 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 46932.37 | 49012449.93 |
November | 0.00 | 82117958.92 | 0.247340E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74476828.94 |
December | 0.00 | 85430053.17 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93456552.10 |
Annual Sum or Average | 0.00 | 0.100027E+10 | 0.300992E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28777946.19 | 0.643283E+09 |
Minimum of Months | 0.00 | 76846309.13 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2119898.45 |
Maximum of Months | 0.00 | 85430053.17 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11548446.44 | 0.104003E+09 |
Report: SpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 85115186.72 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109678E+09 |
February | 0.273974E+09 | 76867322.62 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105413E+09 |
March | 0.303685E+09 | 84438732.44 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4843.07 | 84651823.64 |
April | 0.293479E+09 | 82467551.52 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 279325.13 | 53890791.38 |
May | 0.303504E+09 | 84776959.58 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1178497.26 | 29681723.63 |
June | 0.293842E+09 | 81813276.33 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6736871.42 | 6217573.15 |
July | 0.303141E+09 | 85442324.32 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17451722.51 | 308436.06 |
August | 0.303685E+09 | 84438732.44 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17737844.97 | 1813905.71 |
September | 0.293479E+09 | 82489730.61 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4143749.98 | 11881147.07 |
October | 0.303322E+09 | 85104097.18 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 284914.92 | 39122470.12 |
November | 0.293661E+09 | 82140413.93 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72148563.75 |
December | 0.303141E+09 | 85453413.86 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95766023.45 |
Annual Sum or Average | 0.357224E+10 | 0.100055E+10 | 0.301074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47817769.26 | 0.610574E+09 |
Minimum of Months | 0.273974E+09 | 76867322.62 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 308436.06 |
Maximum of Months | 0.303685E+09 | 85453413.86 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17737844.97 | 0.109678E+09 |
Report: SpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135397E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392192E+09 |
February | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379714E+09 |
March | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17346.45 | 0.307129E+09 |
April | 0.293479E+09 | 0.131185E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 729514.40 | 0.196661E+09 |
May | 0.303504E+09 | 0.134859E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3774365.38 | 0.110113E+09 |
June | 0.293842E+09 | 0.130145E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22484343.10 | 24171311.82 |
July | 0.303141E+09 | 0.135918E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60307669.77 | 1236478.41 |
August | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60776260.54 | 6975082.52 |
September | 0.293479E+09 | 0.131221E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13003681.65 | 45782448.30 |
October | 0.303322E+09 | 0.135380E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 481972.16 | 0.147026E+09 |
November | 0.293661E+09 | 0.130665E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260347E+09 |
December | 0.303141E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343405E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159162E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161575E+09 | 0.221475E+10 |
Minimum of Months | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1236478.41 |
Maximum of Months | 0.303685E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60776260.54 | 0.392192E+09 |
Report: SpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135381E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388850E+09 |
February | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.375059E+09 |
March | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17353.23 | 0.302445E+09 |
April | 0.293479E+09 | 0.131170E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 735990.62 | 0.194989E+09 |
May | 0.303504E+09 | 0.134843E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3776880.91 | 0.109899E+09 |
June | 0.293842E+09 | 0.130129E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22490839.85 | 24148971.55 |
July | 0.303141E+09 | 0.135902E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60317267.03 | 1232169.96 |
August | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60828595.59 | 6962107.12 |
September | 0.293479E+09 | 0.131205E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13062041.66 | 45325989.49 |
October | 0.303322E+09 | 0.135364E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 489177.23 | 0.144094E+09 |
November | 0.293661E+09 | 0.130650E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256109E+09 |
December | 0.303141E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338815E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159144E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161718E+09 | 0.218793E+10 |
Minimum of Months | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1232169.96 |
Maximum of Months | 0.303685E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60828595.59 | 0.388850E+09 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.385223E+10 | 0.232638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.481226E+09 |
February | 0.348285E+10 | 0.210051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462495E+09 |
March | 0.387034E+10 | 0.233355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7171.80 | 0.372558E+09 |
April | 0.373454E+10 | 0.224750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 863095.94 | 0.245040E+09 |
May | 0.386038E+10 | 0.233041E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3360146.76 | 0.151302E+09 |
June | 0.374269E+10 | 0.225781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16395209.09 | 53929184.49 |
July | 0.385223E+10 | 0.232011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39963275.87 | 11801299.79 |
August | 0.386853E+10 | 0.233445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42962935.57 | 23205373.36 |
September | 0.373273E+10 | 0.224840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6738829.93 | 79727427.39 |
October | 0.385404E+10 | 0.232548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 307856.57 | 0.201317E+09 |
November | 0.372639E+10 | 0.225602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321086E+09 |
December | 0.385223E+10 | 0.232011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420086E+09 |
Annual Sum or Average | 0.454292E+11 | 0.274007E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110599E+09 | 0.282377E+10 |
Minimum of Months | 0.348285E+10 | 0.210051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11801299.79 |
Maximum of Months | 0.387034E+10 | 0.233445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42962935.57 | 0.481226E+09 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135397E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392026E+09 |
February | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379108E+09 |
March | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15354.17 | 0.305851E+09 |
April | 0.293479E+09 | 0.131185E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 702678.23 | 0.195595E+09 |
May | 0.303504E+09 | 0.134859E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3689974.70 | 0.110026E+09 |
June | 0.293842E+09 | 0.130145E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22094723.35 | 24426796.46 |
July | 0.303141E+09 | 0.135918E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59503686.24 | 1265355.08 |
August | 0.303685E+09 | 0.134321E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59973380.50 | 6915103.31 |
September | 0.293479E+09 | 0.131221E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12642078.12 | 45755355.49 |
October | 0.303322E+09 | 0.135380E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 446996.36 | 0.146454E+09 |
November | 0.293661E+09 | 0.130665E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258879E+09 |
December | 0.303141E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342924E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159162E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159069E+09 | 0.220923E+10 |
Minimum of Months | 0.273974E+09 | 0.122277E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1265355.08 |
Maximum of Months | 0.303685E+09 | 0.135935E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59973380.50 | 0.392026E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.135381E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389248E+09 |
February | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.375187E+09 |
March | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15382.50 | 0.301273E+09 |
April | 0.293479E+09 | 0.131170E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 751197.80 | 0.193448E+09 |
May | 0.303504E+09 | 0.134843E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3708002.31 | 0.109456E+09 |
June | 0.293842E+09 | 0.130129E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22127106.09 | 24361064.05 |
July | 0.303141E+09 | 0.135902E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59544572.71 | 1260271.93 |
August | 0.303685E+09 | 0.134305E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60162062.68 | 6863093.06 |
September | 0.293479E+09 | 0.131205E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12809558.96 | 44851892.93 |
October | 0.303322E+09 | 0.135364E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 525534.44 | 0.142723E+09 |
November | 0.293661E+09 | 0.130650E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.254784E+09 |
December | 0.303141E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338838E+09 |
Annual Sum or Average | 0.357224E+10 | 0.159144E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159643E+09 | 0.218229E+10 |
Minimum of Months | 0.273974E+09 | 0.122263E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1260271.93 |
Maximum of Months | 0.303685E+09 | 0.135919E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60162062.68 | 0.389248E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 85115186.72 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204371E+09 |
February | 0.273974E+09 | 76867322.62 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198033E+09 |
March | 0.303685E+09 | 84438732.44 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7867.90 | 0.158945E+09 |
April | 0.293479E+09 | 82467551.52 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 358159.66 | 0.101174E+09 |
May | 0.303504E+09 | 84776959.58 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1902667.14 | 56366643.78 |
June | 0.293842E+09 | 81813276.33 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11352646.52 | 12347916.70 |
July | 0.303141E+09 | 85442324.32 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30514142.22 | 639627.77 |
August | 0.303685E+09 | 84438732.44 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30735835.08 | 3542922.21 |
September | 0.293479E+09 | 82489730.61 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6462194.59 | 23629787.99 |
October | 0.303322E+09 | 85104097.18 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 215698.19 | 75926549.48 |
November | 0.293661E+09 | 82140413.93 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136260E+09 |
December | 0.303141E+09 | 85453413.86 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179450E+09 |
Annual Sum or Average | 0.357224E+10 | 0.100055E+10 | 0.301074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81549211.28 | 0.115069E+10 |
Minimum of Months | 0.273974E+09 | 76867322.62 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 639627.77 |
Maximum of Months | 0.303685E+09 | 85453413.86 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30735835.08 | 0.204371E+09 |
Report: SpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.303429E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108053E+10 |
February | 0.415303E+11 | 0.270887E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103224E+10 |
March | 0.461508E+11 | 0.296851E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.867163E+09 |
April | 0.445315E+11 | 0.281177E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 771158.75 | 0.588298E+09 |
May | 0.460320E+11 | 0.285834E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4606049.30 | 0.372159E+09 |
June | 0.446286E+11 | 0.274883E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 27322772.71 | 0.132128E+09 |
July | 0.459349E+11 | 0.282901E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 71899091.06 | 30555807.52 |
August | 0.461292E+11 | 0.289613E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 81807965.51 | 52599862.88 |
September | 0.445099E+11 | 0.284038E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 11669046.03 | 0.193338E+09 |
October | 0.459565E+11 | 0.298860E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 259719.63 | 0.462686E+09 |
November | 0.444343E+11 | 0.292070E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.750666E+09 |
December | 0.459349E+11 | 0.302980E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.962331E+09 |
Annual Sum or Average | 0.541708E+12 | 0.346352E+11 | 0.175857E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198336E+09 | 0.652470E+10 |
Minimum of Months | 0.415303E+11 | 0.270887E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30555807.52 |
Maximum of Months | 0.461508E+11 | 0.303429E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 81807965.51 | 0.108053E+10 |
Report: SpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.303429E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109252E+10 |
February | 0.415303E+11 | 0.270887E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104278E+10 |
March | 0.461508E+11 | 0.296851E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.875336E+09 |
April | 0.445315E+11 | 0.281177E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 715444.40 | 0.594056E+09 |
May | 0.460320E+11 | 0.285834E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4567470.55 | 0.374801E+09 |
June | 0.446286E+11 | 0.274883E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 27161315.74 | 0.132820E+09 |
July | 0.459349E+11 | 0.282901E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 71709094.91 | 30589204.65 |
August | 0.461292E+11 | 0.289613E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 81419241.51 | 52706893.47 |
September | 0.445099E+11 | 0.284038E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 11469452.72 | 0.194843E+09 |
October | 0.459565E+11 | 0.298860E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 194094.59 | 0.466629E+09 |
November | 0.444343E+11 | 0.292070E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.758718E+09 |
December | 0.459349E+11 | 0.302980E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.972164E+09 |
Annual Sum or Average | 0.541708E+12 | 0.346352E+11 | 0.175857E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197236E+09 | 0.658797E+10 |
Minimum of Months | 0.415303E+11 | 0.270887E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30589204.65 |
Maximum of Months | 0.461508E+11 | 0.303429E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 81419241.51 | 0.109252E+10 |
Report: SpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.408770E+10 | 0.113146E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.987480E+09 |
February | 0.369574E+10 | 0.102161E+10 | 0.301256E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.941499E+09 |
March | 0.410691E+10 | 0.113495E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.788620E+09 |
April | 0.396281E+10 | 0.109310E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 583727.01 | 0.532045E+09 |
May | 0.409635E+10 | 0.113342E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 4019203.52 | 0.332941E+09 |
June | 0.397146E+10 | 0.109811E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 23936559.39 | 0.116981E+09 |
July | 0.408770E+10 | 0.112841E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 64296095.41 | 26353270.60 |
August | 0.410499E+10 | 0.113539E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 72335309.63 | 46083550.30 |
September | 0.396089E+10 | 0.109354E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 10056271.14 | 0.172206E+09 |
October | 0.408962E+10 | 0.113103E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 109198.17 | 0.417410E+09 |
November | 0.395417E+10 | 0.109724E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.684490E+09 |
December | 0.408770E+10 | 0.112841E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877566E+09 |
Annual Sum or Average | 0.482060E+11 | 0.133267E+11 | 0.392709E+12 | 0.359593E+12 | 0.00 | 0.00 | 0.00 | 0.175336E+09 | 0.592368E+10 |
Minimum of Months | 0.369574E+10 | 0.102161E+10 | 0.301256E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 26353270.60 |
Maximum of Months | 0.410691E+10 | 0.113539E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 72335309.63 | 0.987480E+09 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.407704E+10 | 0.246211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.854179E+09 |
February | 0.368610E+10 | 0.222306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.821200E+09 |
March | 0.409620E+10 | 0.246970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 539.80 | 0.661669E+09 |
April | 0.395248E+10 | 0.237864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1053697.82 | 0.433561E+09 |
May | 0.408566E+10 | 0.246638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4533839.94 | 0.268771E+09 |
June | 0.396110E+10 | 0.238954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25254024.76 | 96501456.94 |
July | 0.407704E+10 | 0.245547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65362654.80 | 20612609.59 |
August | 0.409429E+10 | 0.247065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73001553.01 | 39020241.98 |
September | 0.395056E+10 | 0.237958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10778491.62 | 0.138605E+09 |
October | 0.407896E+10 | 0.246116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 305180.14 | 0.345901E+09 |
November | 0.394385E+10 | 0.238765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.565685E+09 |
December | 0.407704E+10 | 0.245547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.746037E+09 |
Annual Sum or Average | 0.480803E+11 | 0.289994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180290E+09 | 0.499174E+10 |
Minimum of Months | 0.368610E+10 | 0.222306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20612609.59 |
Maximum of Months | 0.409620E+10 | 0.247065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73001553.01 | 0.854179E+09 |
Report: PeakSpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 11501.89 | 02-JAN-00:10 | 14185.34 | 02-JAN-20:10 | 10113.80 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 11501.89 | 01-FEB-00:10 | 14185.34 | 01-FEB-20:10 | 10113.80 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11501.89 | 01-MAR-00:10 | 14185.34 | 01-MAR-20:10 | 10113.80 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11501.89 | 01-APR-00:10 | 14185.34 | 03-APR-19:10 | 10113.80 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11501.89 | 01-MAY-00:10 | 14185.34 | 01-MAY-19:10 | 10113.80 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 11501.89 | 01-JUN-00:10 | 14185.34 | 01-JUN-19:10 | 10113.80 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 11501.89 | 01-JUL-00:10 | 14185.34 | 03-JUL-19:10 | 10113.80 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11501.89 | 01-AUG-00:10 | 14185.34 | 01-AUG-19:10 | 10113.80 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 11501.89 | 01-SEP-00:10 | 14185.34 | 01-SEP-19:10 | 10113.80 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 11501.89 | 01-OCT-23:10 | 14185.34 | 02-OCT-19:10 | 10113.80 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 11501.89 | 01-NOV-00:10 | 14185.34 | 01-NOV-19:10 | 10113.80 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 11501.89 | 01-DEC-00:10 | 14185.34 | 01-DEC-20:10 | 10113.80 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 11501.89 | 14185.34 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 11501.89 | 14185.34 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1169.53 | 02-JAN-00:10 | 704.41 | 02-JAN-20:10 | 685.60 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 452.52 | 02-JAN-05:00 |
February | 1169.53 | 01-FEB-00:10 | 704.41 | 01-FEB-20:10 | 685.60 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 464.93 | 06-FEB-03:00 |
March | 1169.53 | 01-MAR-00:10 | 704.41 | 01-MAR-20:10 | 685.60 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 343.22 | 23-MAR-06:00 |
April | 1169.53 | 01-APR-00:10 | 704.41 | 03-APR-19:10 | 685.60 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.91 | 08-APR-10:00 | 242.07 | 03-APR-06:00 |
May | 1169.53 | 01-MAY-00:10 | 704.41 | 01-MAY-19:10 | 685.60 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.45 | 30-MAY-13:00 | 187.97 | 01-MAY-05:00 |
June | 1169.53 | 01-JUN-00:10 | 704.41 | 01-JUN-19:10 | 685.60 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.94 | 19-JUN-12:00 | 99.35 | 03-JUN-03:00 |
July | 1169.53 | 01-JUL-00:10 | 704.41 | 03-JUL-19:10 | 685.60 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.65 | 07-JUL-12:00 | 40.98 | 01-JUL-23:00 |
August | 1169.53 | 01-AUG-00:10 | 704.41 | 01-AUG-19:10 | 685.60 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.87 | 24-AUG-15:00 | 79.96 | 08-AUG-05:00 |
September | 1169.53 | 01-SEP-00:10 | 704.41 | 01-SEP-19:10 | 685.60 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.75 | 01-SEP-14:00 | 139.19 | 30-SEP-01:00 |
October | 1169.53 | 01-OCT-23:10 | 704.41 | 02-OCT-19:10 | 685.60 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.68 | 04-OCT-13:00 | 243.51 | 09-OCT-06:00 |
November | 1169.53 | 01-NOV-00:10 | 704.41 | 01-NOV-19:10 | 685.60 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 334.28 | 24-NOV-07:00 |
December | 1169.53 | 01-DEC-00:10 | 704.41 | 01-DEC-20:10 | 685.60 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 389.28 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1169.53 | 704.41 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.98 | |||||
Maximum of Months | 1169.53 | 704.41 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 142.94 | 464.93 |
Report: PeakSpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1354.32 | 02-JAN-00:10 | 815.72 | 02-JAN-20:10 | 793.93 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 174.66 | 02-JAN-05:00 |
February | 1354.32 | 01-FEB-00:10 | 815.72 | 01-FEB-20:10 | 793.93 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 179.45 | 06-FEB-03:00 |
March | 1354.32 | 01-MAR-00:10 | 815.72 | 01-MAR-20:10 | 793.93 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 136.28 | 23-MAR-06:00 |
April | 1354.32 | 01-APR-00:10 | 815.72 | 03-APR-19:10 | 793.93 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.85 | 07-APR-13:00 | 97.79 | 03-APR-06:00 |
May | 1354.32 | 01-MAY-00:10 | 815.72 | 01-MAY-19:10 | 793.93 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.24 | 30-MAY-13:00 | 78.96 | 01-MAY-05:00 |
June | 1354.32 | 01-JUN-00:10 | 815.72 | 01-JUN-19:10 | 793.93 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.78 | 19-JUN-12:00 | 47.86 | 03-JUN-03:00 |
July | 1354.32 | 01-JUL-00:10 | 815.72 | 03-JUL-19:10 | 793.93 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.20 | 07-JUL-12:00 | 24.03 | 02-JUL-03:00 |
August | 1354.32 | 01-AUG-00:10 | 815.72 | 01-AUG-19:10 | 793.93 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.42 | 24-AUG-15:00 | 40.38 | 08-AUG-05:00 |
September | 1354.32 | 01-SEP-00:10 | 815.72 | 01-SEP-19:10 | 793.93 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.19 | 01-SEP-14:00 | 62.47 | 30-SEP-01:00 |
October | 1354.32 | 01-OCT-23:10 | 815.72 | 02-OCT-19:10 | 793.93 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 25-OCT-10:53 | 101.38 | 09-OCT-06:00 |
November | 1354.32 | 01-NOV-00:10 | 815.72 | 01-NOV-19:10 | 793.93 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 130.81 | 24-NOV-07:00 |
December | 1354.32 | 01-DEC-00:10 | 815.72 | 01-DEC-20:10 | 793.93 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 151.67 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1354.32 | 815.72 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.03 | |||||
Maximum of Months | 1354.32 | 815.72 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 58.78 | 179.45 |
Report: PeakSpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 286.42 | 02-JAN-00:10 | 1360.40 | 02-JAN-20:10 | 839.45 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 412.79 | 02-JAN-05:00 |
February | 286.42 | 01-FEB-00:10 | 1360.40 | 01-FEB-20:10 | 839.45 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 424.08 | 06-FEB-03:00 |
March | 286.42 | 01-MAR-00:10 | 1360.40 | 01-MAR-20:10 | 839.45 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.32 | 27-MAR-16:00 | 313.10 | 23-MAR-06:00 |
April | 286.42 | 01-APR-00:10 | 1360.40 | 03-APR-19:10 | 839.45 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.24 | 07-APR-13:00 | 220.79 | 03-APR-06:00 |
May | 286.42 | 01-MAY-00:10 | 1360.40 | 01-MAY-19:10 | 839.45 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.63 | 30-MAY-13:00 | 176.96 | 01-MAY-05:00 |
June | 286.42 | 01-JUN-00:10 | 1360.40 | 01-JUN-19:10 | 839.45 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.85 | 19-JUN-12:00 | 107.05 | 03-JUN-03:00 |
July | 286.42 | 01-JUL-00:10 | 1360.40 | 03-JUL-19:10 | 839.45 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.40 | 07-JUL-12:00 | 54.11 | 02-JUL-03:00 |
August | 286.42 | 01-AUG-00:10 | 1360.40 | 01-AUG-19:10 | 839.45 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.07 | 24-AUG-16:00 | 91.98 | 08-AUG-05:00 |
September | 286.42 | 01-SEP-00:10 | 1360.40 | 01-SEP-19:10 | 839.45 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.32 | 01-SEP-14:00 | 140.16 | 24-SEP-06:00 |
October | 286.42 | 01-OCT-23:10 | 1360.40 | 02-OCT-19:10 | 839.45 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.62 | 25-OCT-10:53 | 229.74 | 09-OCT-06:00 |
November | 286.42 | 01-NOV-00:10 | 1360.40 | 01-NOV-19:10 | 839.45 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 304.94 | 24-NOV-07:00 |
December | 286.42 | 01-DEC-00:10 | 1360.40 | 01-DEC-20:10 | 839.45 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 355.13 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 286.42 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.11 | |||||
Maximum of Months | 286.42 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 137.85 | 424.08 |
Report: PeakSpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 220.32 | 02-JAN-00:10 | 227.72 | 02-JAN-20:10 | 242.16 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 238.15 | 02-JAN-05:00 |
February | 220.32 | 01-FEB-00:10 | 227.72 | 01-FEB-20:10 | 242.16 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 244.68 | 06-FEB-03:00 |
March | 220.32 | 01-MAR-00:10 | 227.72 | 01-MAR-20:10 | 242.16 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.98 | 27-MAR-16:00 | 180.64 | 23-MAR-06:00 |
April | 220.32 | 01-APR-00:10 | 227.72 | 03-APR-19:10 | 242.16 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.48 | 07-APR-13:00 | 127.39 | 03-APR-06:00 |
May | 220.32 | 01-MAY-00:10 | 227.72 | 01-MAY-19:10 | 242.16 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.14 | 30-MAY-13:00 | 101.16 | 01-MAY-05:00 |
June | 220.32 | 01-JUN-00:10 | 227.72 | 01-JUN-19:10 | 242.16 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.47 | 19-JUN-12:00 | 61.05 | 03-JUN-03:00 |
July | 220.32 | 01-JUL-00:10 | 227.72 | 03-JUL-19:10 | 242.16 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.95 | 07-JUL-12:00 | 30.16 | 02-JUL-03:00 |
August | 220.32 | 01-AUG-00:10 | 227.72 | 01-AUG-19:10 | 242.16 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.47 | 24-AUG-16:00 | 52.31 | 08-AUG-05:00 |
September | 220.32 | 01-SEP-00:10 | 227.72 | 01-SEP-19:10 | 242.16 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.26 | 01-SEP-14:00 | 79.33 | 24-SEP-06:00 |
October | 220.32 | 01-OCT-23:10 | 227.72 | 02-OCT-19:10 | 242.16 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.92 | 25-OCT-10:53 | 131.14 | 09-OCT-04:00 |
November | 220.32 | 01-NOV-00:10 | 227.72 | 01-NOV-19:10 | 242.16 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 175.93 | 24-NOV-07:00 |
December | 220.32 | 01-DEC-00:10 | 227.72 | 01-DEC-20:10 | 242.16 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 204.89 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 220.32 | 227.72 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.16 | |||||
Maximum of Months | 220.32 | 227.72 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 79.47 | 244.68 |
Report: PeakSpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 907.20 | 02-JAN-00:10 | 357.21 | 02-JAN-20:10 | 4572.80 | 02-JAN-20:10 | 39726.58 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 602.22 | 02-JAN-07:10 |
February | 907.20 | 01-FEB-00:10 | 357.21 | 01-FEB-20:10 | 4572.80 | 01-FEB-20:10 | 39726.58 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 615.14 | 06-FEB-07:10 |
March | 907.20 | 01-MAR-00:10 | 357.21 | 01-MAR-20:10 | 4572.80 | 01-MAR-20:10 | 39726.58 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.54 | 27-MAR-16:00 | 475.52 | 23-MAR-06:00 |
April | 907.20 | 01-APR-00:10 | 357.21 | 03-APR-19:10 | 4572.80 | 03-APR-19:10 | 39726.58 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 58.59 | 07-APR-13:00 | 349.03 | 03-APR-06:00 |
May | 907.20 | 01-MAY-00:10 | 357.21 | 01-MAY-19:10 | 4572.80 | 01-MAY-19:10 | 39726.58 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 108.08 | 30-MAY-10:50 | 293.95 | 01-MAY-06:05 |
June | 907.20 | 01-JUN-00:10 | 357.21 | 01-JUN-19:10 | 4572.80 | 01-JUN-19:10 | 39726.58 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 203.65 | 19-JUN-12:00 | 152.38 | 02-JUN-06:00 |
July | 907.20 | 01-JUL-00:10 | 357.21 | 03-JUL-19:10 | 4572.80 | 03-JUL-19:10 | 39726.58 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 166.66 | 07-JUL-10:50 | 76.05 | 01-JUL-23:20 |
August | 907.20 | 01-AUG-00:10 | 357.21 | 01-AUG-19:10 | 4572.80 | 01-AUG-19:10 | 39726.58 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 166.25 | 24-AUG-16:00 | 129.79 | 08-AUG-05:10 |
September | 907.20 | 01-SEP-00:10 | 357.21 | 01-SEP-19:10 | 4572.80 | 01-SEP-19:10 | 39726.58 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 114.40 | 01-SEP-14:20 | 212.74 | 24-SEP-05:34 |
October | 907.20 | 01-OCT-23:10 | 357.21 | 02-OCT-19:10 | 4572.80 | 02-OCT-19:10 | 39726.58 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 45.81 | 25-OCT-10:50 | 357.01 | 31-OCT-06:10 |
November | 907.20 | 01-NOV-00:10 | 357.21 | 01-NOV-19:10 | 4572.80 | 01-NOV-19:10 | 39726.58 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 463.42 | 24-NOV-07:10 |
December | 907.20 | 01-DEC-00:10 | 357.21 | 01-DEC-20:10 | 4572.80 | 01-DEC-20:10 | 39726.58 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 524.77 | 31-DEC-23:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 907.20 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 76.05 | ||||||
Maximum of Months | 907.20 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 203.65 | 615.14 |
Report: PeakSpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 15368.40 | 02-JAN-00:10 | 1761.91 | 02-JAN-20:10 | 965.27 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 1000.36 | 02-JAN-05:00 |
February | 15368.40 | 01-FEB-00:10 | 1761.91 | 01-FEB-20:10 | 965.27 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 1027.76 | 06-FEB-03:00 |
March | 15368.40 | 01-MAR-00:10 | 1761.91 | 01-MAR-20:10 | 965.27 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 784.54 | 23-MAR-04:20 |
April | 15368.40 | 01-APR-00:10 | 1761.91 | 03-APR-19:10 | 965.27 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.19 | 07-APR-13:00 | 557.43 | 01-APR-04:00 |
May | 15368.40 | 01-MAY-00:10 | 1761.91 | 01-MAY-19:10 | 965.27 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.54 | 30-MAY-13:00 | 456.35 | 01-MAY-05:00 |
June | 15368.40 | 01-JUN-00:10 | 1761.91 | 01-JUN-19:19 | 965.27 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 317.10 | 19-JUN-10:55 | 279.51 | 03-JUN-03:00 |
July | 15368.40 | 01-JUL-00:10 | 1761.91 | 03-JUL-19:19 | 965.27 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 249.03 | 07-JUL-12:00 | 129.53 | 02-JUL-03:00 |
August | 15368.40 | 01-AUG-00:10 | 1761.91 | 01-AUG-19:10 | 965.27 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.32 | 24-AUG-15:30 | 234.41 | 08-AUG-05:00 |
September | 15368.40 | 01-SEP-00:10 | 1761.91 | 01-SEP-19:10 | 965.27 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.52 | 01-SEP-14:00 | 363.60 | 30-SEP-01:00 |
October | 15368.40 | 01-OCT-23:10 | 1761.91 | 02-OCT-19:10 | 965.27 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.84 | 04-OCT-13:00 | 570.84 | 29-OCT-07:00 |
November | 15368.40 | 01-NOV-00:10 | 1761.91 | 01-NOV-19:10 | 965.27 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 757.50 | 24-NOV-06:00 |
December | 15368.40 | 01-DEC-00:10 | 1761.91 | 01-DEC-20:10 | 965.27 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 861.61 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 15368.40 | 1761.91 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.53 | |||||
Maximum of Months | 15368.40 | 1761.91 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 317.10 | 1027.76 |
Report: PeakSpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 45622.98 | 02-JAN-00:10 | 10265.18 | 02-JAN-20:10 | 10029.21 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 2907.27 | 02-JAN-05:00 |
February | 45622.98 | 01-FEB-00:10 | 10265.18 | 01-FEB-20:10 | 10029.21 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 3001.78 | 06-FEB-03:00 |
March | 45622.98 | 01-MAR-00:10 | 10265.18 | 01-MAR-20:10 | 10029.21 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 2306.84 | 23-MAR-04:40 |
April | 45622.98 | 01-APR-00:10 | 10265.18 | 03-APR-19:10 | 10029.21 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 241.85 | 07-APR-13:00 | 1658.37 | 03-APR-06:00 |
May | 45622.98 | 01-MAY-00:10 | 10265.18 | 01-MAY-19:10 | 10029.21 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 488.89 | 30-MAY-13:00 | 1366.04 | 01-MAY-05:00 |
June | 45622.98 | 01-JUN-00:10 | 10265.18 | 01-JUN-19:10 | 10029.21 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 950.79 | 19-JUN-12:00 | 824.70 | 03-JUN-03:00 |
July | 45622.98 | 01-JUL-00:10 | 10265.18 | 03-JUL-19:19 | 10029.21 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 749.67 | 07-JUL-12:00 | 420.50 | 02-JUL-03:00 |
August | 45622.98 | 01-AUG-00:10 | 10265.18 | 01-AUG-19:10 | 10029.21 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 711.72 | 24-AUG-15:00 | 694.66 | 08-AUG-05:00 |
September | 45622.98 | 01-SEP-00:10 | 10265.18 | 01-SEP-19:10 | 10029.21 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.23 | 01-SEP-14:00 | 1053.09 | 30-SEP-01:00 |
October | 45622.98 | 01-OCT-23:10 | 10265.18 | 02-OCT-19:10 | 10029.21 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.57 | 25-OCT-10:53 | 1707.40 | 09-OCT-06:00 |
November | 45622.98 | 01-NOV-00:10 | 10265.18 | 01-NOV-19:10 | 10029.21 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 2229.00 | 24-NOV-06:00 |
December | 45622.98 | 01-DEC-00:10 | 10265.18 | 01-DEC-20:10 | 10029.21 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 2549.01 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 45622.98 | 10265.18 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 420.50 | |||||
Maximum of Months | 45622.98 | 10265.18 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 950.79 | 3001.78 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.50 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 263.84 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.50 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.01 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.50 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 27-MAR-16:00 | 200.38 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.50 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.43 | 08-APR-10:00 | 141.62 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.50 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.23 | 30-MAY-16:00 | 110.20 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.50 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 19-JUN-12:00 | 55.64 | 03-JUN-03:00 |
July | 180.00 | 01-JUL-00:10 | 122.50 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.78 | 10-JUL-15:10 | 19.90 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.50 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.59 | 24-AUG-16:00 | 43.66 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.50 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.95 | 01-SEP-15:10 | 80.65 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.50 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.89 | 04-OCT-15:10 | 142.49 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.50 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.18 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.50 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.13 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.90 | |||||
Maximum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 271.01 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.49 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 263.82 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.49 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.00 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.49 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.18 | 27-MAR-16:00 | 200.36 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.49 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.43 | 08-APR-10:00 | 141.61 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.49 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.23 | 30-MAY-16:00 | 110.19 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.49 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.03 | 19-JUN-12:00 | 55.64 | 03-JUN-03:00 |
July | 180.00 | 01-JUL-00:10 | 122.49 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.80 | 10-JUL-15:10 | 19.90 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.49 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.58 | 24-AUG-15:50 | 43.66 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.49 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.00 | 01-SEP-15:10 | 80.64 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.49 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.47 | 04-OCT-15:10 | 142.47 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.49 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.17 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.49 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.10 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.90 | |||||
Maximum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 87.03 | 271.00 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 76.99 | 01-JAN-19:10 | 232.19 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 68.71 | 02-JAN-05:00 |
February | 0.00 | 01-FEB-00:10 | 76.99 | 01-FEB-20:10 | 232.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 70.82 | 06-FEB-03:00 |
March | 0.00 | 01-MAR-00:10 | 76.99 | 01-MAR-20:10 | 232.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 53.42 | 23-MAR-06:00 |
April | 0.00 | 01-APR-00:10 | 76.99 | 01-APR-18:10 | 232.19 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.24 | 07-APR-13:00 | 38.26 | 12-APR-06:20 |
May | 0.00 | 01-MAY-00:10 | 76.99 | 01-MAY-19:10 | 232.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.42 | 30-MAY-13:00 | 30.84 | 15-MAY-03:00 |
June | 0.00 | 01-JUN-00:10 | 76.99 | 01-JUN-19:10 | 232.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.29 | 19-JUN-12:00 | 18.86 | 03-JUN-02:55 |
July | 0.00 | 01-JUL-00:10 | 76.99 | 01-JUL-18:10 | 232.19 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.39 | 07-JUL-12:00 | 9.36 | 02-JUL-03:00 |
August | 0.00 | 01-AUG-00:10 | 76.99 | 01-AUG-19:10 | 232.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.26 | 24-AUG-15:00 | 15.93 | 08-AUG-05:00 |
September | 0.00 | 01-SEP-00:10 | 76.99 | 01-SEP-19:10 | 232.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.23 | 01-SEP-14:00 | 25.49 | 30-SEP-01:00 |
October | 0.00 | 01-OCT-00:10 | 76.99 | 01-OCT-18:10 | 232.19 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 04-OCT-13:00 | 41.86 | 29-OCT-07:00 |
November | 0.00 | 01-NOV-00:10 | 76.99 | 01-NOV-19:10 | 232.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 51.32 | 24-NOV-08:00 |
December | 0.00 | 01-DEC-00:10 | 76.99 | 01-DEC-20:10 | 232.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 58.59 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 0.00 | 76.99 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.36 | |||||
Maximum of Months | 0.00 | 76.99 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 24.29 | 70.82 |
Report: PeakSpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 77.01 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 73.63 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 77.01 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 75.64 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 77.01 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27-MAR-16:00 | 55.92 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 77.01 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 08-APR-10:00 | 39.52 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 77.01 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.46 | 30-MAY-16:00 | 30.76 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 77.01 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.66 | 19-JUN-12:00 | 15.53 | 03-JUN-03:00 |
July | 180.00 | 01-JUL-00:10 | 77.01 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.72 | 10-JUL-15:10 | 5.55 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 77.01 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.33 | 24-AUG-15:10 | 12.19 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 77.01 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.75 | 01-SEP-15:10 | 22.51 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 77.01 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.09 | 25-OCT-10:53 | 39.77 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 77.01 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 54.47 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 77.01 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 63.39 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 77.01 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.55 | |||||
Maximum of Months | 180.00 | 77.01 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 24.66 | 75.64 |
Report: PeakSpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.50 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 263.84 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.50 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.02 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.50 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.18 | 27-MAR-16:00 | 200.38 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.50 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.42 | 08-APR-10:00 | 141.62 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.50 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.24 | 30-MAY-16:00 | 110.20 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.50 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 19-JUN-12:00 | 60.96 | 02-JUN-07:10 |
July | 180.00 | 01-JUL-00:10 | 122.50 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.82 | 10-JUL-15:10 | 19.90 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.50 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.60 | 24-AUG-15:10 | 43.66 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.50 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.01 | 01-SEP-15:10 | 80.65 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.50 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.47 | 04-OCT-15:10 | 142.48 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.50 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.18 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.50 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.12 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.90 | |||||
Maximum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 271.02 |
Report: PeakSpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.49 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 263.82 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.49 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.00 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.49 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.18 | 27-MAR-16:00 | 200.36 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.49 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.43 | 08-APR-10:00 | 141.61 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.49 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.24 | 30-MAY-15:50 | 110.19 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.49 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.03 | 19-JUN-12:00 | 60.95 | 02-JUN-07:10 |
July | 180.00 | 01-JUL-00:10 | 122.49 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.81 | 10-JUL-15:10 | 19.90 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.49 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.59 | 24-AUG-15:10 | 43.66 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.49 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.01 | 01-SEP-15:10 | 80.64 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.49 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.47 | 04-OCT-15:10 | 142.48 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.49 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.17 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.49 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.11 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.90 | |||||
Maximum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 87.03 | 271.00 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2263.36 | 02-JAN-00:10 | 2240.78 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 317.99 | 02-JAN-05:00 |
February | 2263.36 | 01-FEB-00:10 | 2240.78 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 326.69 | 06-FEB-03:00 |
March | 2263.36 | 01-MAR-00:10 | 2240.78 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.95 | 27-MAR-16:00 | 241.28 | 23-MAR-06:00 |
April | 2263.36 | 01-APR-00:10 | 2240.78 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.41 | 07-APR-13:00 | 170.25 | 03-APR-06:00 |
May | 2263.36 | 01-MAY-00:10 | 2240.78 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.55 | 30-MAY-13:00 | 137.65 | 01-MAY-05:00 |
June | 2263.36 | 01-JUN-00:10 | 2240.78 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.47 | 19-JUN-12:00 | 85.41 | 03-JUN-03:00 |
July | 2263.36 | 01-JUL-00:10 | 2240.78 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.74 | 07-JUL-12:00 | 41.99 | 02-JUL-03:00 |
August | 2263.36 | 01-AUG-00:10 | 2240.78 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.17 | 24-AUG-15:00 | 71.89 | 08-AUG-05:00 |
September | 2263.36 | 01-SEP-00:10 | 2240.78 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 | 01-SEP-14:00 | 107.48 | 30-SEP-01:00 |
October | 2263.36 | 01-OCT-23:10 | 2240.78 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.90 | 25-OCT-10:53 | 180.98 | 09-OCT-04:00 |
November | 2263.36 | 01-NOV-00:10 | 2240.78 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 235.00 | 24-NOV-07:00 |
December | 2263.36 | 01-DEC-00:10 | 2240.78 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 273.63 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 2263.36 | 2240.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.99 | ||||
Maximum of Months | 2263.36 | 2240.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.47 | 326.69 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.50 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 264.38 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.50 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.54 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.50 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.77 | 27-MAR-16:00 | 200.87 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.50 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.03 | 08-APR-10:00 | 142.09 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.50 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.81 | 30-MAY-16:00 | 110.66 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.50 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 86.67 | 19-JUN-12:00 | 56.07 | 03-JUN-02:55 |
July | 180.00 | 01-JUL-00:10 | 122.50 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.26 | 10-JUL-15:10 | 20.32 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.50 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.21 | 24-AUG-15:50 | 44.09 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.50 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.56 | 01-SEP-15:10 | 81.09 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.50 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.39 | 04-OCT-15:10 | 142.96 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.50 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.68 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.50 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.63 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.32 | |||||
Maximum of Months | 180.00 | 122.50 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 86.67 | 271.54 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 122.49 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 264.36 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 122.49 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 271.51 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 122.49 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.77 | 27-MAR-16:00 | 200.86 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 122.49 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.03 | 08-APR-10:00 | 142.08 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 122.49 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.80 | 30-MAY-16:00 | 110.65 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 122.49 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 86.66 | 19-JUN-12:00 | 56.07 | 03-JUN-03:00 |
July | 180.00 | 01-JUL-00:10 | 122.49 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.24 | 10-JUL-15:10 | 20.31 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 122.49 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.20 | 24-AUG-16:00 | 44.09 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 122.49 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.61 | 01-SEP-15:10 | 81.09 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 122.49 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.06 | 04-OCT-15:10 | 142.95 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 122.49 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 195.67 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 122.49 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 227.62 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.31 | |||||
Maximum of Months | 180.00 | 122.49 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 86.66 | 271.51 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 77.01 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 135.26 | 02-JAN-05:00 |
February | 180.00 | 01-FEB-00:10 | 77.01 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 138.93 | 06-FEB-03:00 |
March | 180.00 | 01-MAR-00:10 | 77.01 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.46 | 27-MAR-16:00 | 102.78 | 23-MAR-06:00 |
April | 180.00 | 01-APR-00:10 | 77.01 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.90 | 08-APR-10:00 | 72.70 | 03-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 77.01 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.48 | 30-MAY-16:00 | 56.62 | 01-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 77.01 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.34 | 19-JUN-12:00 | 28.69 | 03-JUN-03:00 |
July | 180.00 | 01-JUL-00:10 | 77.01 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.62 | 10-JUL-15:10 | 10.39 | 02-JUL-05:00 |
August | 180.00 | 01-AUG-00:10 | 77.01 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.58 | 24-AUG-16:00 | 22.56 | 08-AUG-05:00 |
September | 180.00 | 01-SEP-00:10 | 77.01 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.48 | 01-SEP-15:10 | 41.49 | 24-SEP-06:00 |
October | 180.00 | 01-OCT-00:10 | 77.01 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.27 | 02-OCT-16:00 | 73.14 | 09-OCT-06:00 |
November | 180.00 | 01-NOV-00:10 | 77.01 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 100.12 | 24-NOV-07:00 |
December | 180.00 | 01-DEC-00:10 | 77.01 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 116.47 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 77.01 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.39 | |||||
Maximum of Months | 180.00 | 77.01 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 44.34 | 138.93 |
Report: PeakSpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3094.06 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 686.67 | 02-JAN-05:00 |
February | 26988.77 | 01-FEB-00:10 | 3094.06 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 704.09 | 06-FEB-03:00 |
March | 26988.77 | 01-MAR-00:10 | 3094.06 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 541.78 | 23-MAR-04:30 |
April | 26988.77 | 01-APR-00:10 | 3094.06 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.86 | 07-APR-13:00 | 399.59 | 03-APR-06:00 |
May | 26988.77 | 01-MAY-00:10 | 3094.06 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.79 | 30-MAY-13:00 | 321.76 | 01-MAY-05:00 |
June | 26988.77 | 01-JUN-00:10 | 3094.06 | 01-JUN-19:19 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.01 | 19-JUN-12:00 | 187.54 | 03-JUN-04:00 |
July | 26988.77 | 01-JUL-00:10 | 3094.06 | 03-JUL-19:30 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.05 | 07-JUL-12:00 | 98.67 | 02-JUL-05:00 |
August | 26988.77 | 01-AUG-00:10 | 3094.06 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.97 | 24-AUG-15:40 | 157.62 | 08-AUG-05:00 |
September | 26988.77 | 01-SEP-00:10 | 3094.06 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.84 | 01-SEP-14:00 | 251.48 | 24-SEP-05:34 |
October | 26988.77 | 01-OCT-23:10 | 3094.06 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.55 | 25-OCT-10:53 | 402.04 | 09-OCT-06:00 |
November | 26988.77 | 01-NOV-00:10 | 3094.06 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 526.84 | 24-NOV-06:00 |
December | 26988.77 | 01-DEC-00:10 | 3094.06 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 610.14 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.67 | |||||
Maximum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 201.01 | 704.09 |
Report: PeakSpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3094.06 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 690.87 | 02-JAN-05:00 |
February | 26988.77 | 01-FEB-00:10 | 3094.06 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 708.36 | 06-FEB-03:00 |
March | 26988.77 | 01-MAR-00:10 | 3094.06 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 544.42 | 23-MAR-06:00 |
April | 26988.77 | 01-APR-00:10 | 3094.06 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.28 | 07-APR-13:00 | 399.59 | 03-APR-06:00 |
May | 26988.77 | 01-MAY-00:10 | 3094.06 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.79 | 30-MAY-13:00 | 321.76 | 01-MAY-05:00 |
June | 26988.77 | 01-JUN-00:10 | 3094.06 | 01-JUN-19:19 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.00 | 19-JUN-12:00 | 187.56 | 03-JUN-04:00 |
July | 26988.77 | 01-JUL-00:10 | 3094.06 | 03-JUL-19:30 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.05 | 07-JUL-12:00 | 98.67 | 02-JUL-05:00 |
August | 26988.77 | 01-AUG-00:10 | 3094.06 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.97 | 24-AUG-15:40 | 157.62 | 08-AUG-05:00 |
September | 26988.77 | 01-SEP-00:10 | 3094.06 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.84 | 01-SEP-14:00 | 252.62 | 24-SEP-05:34 |
October | 26988.77 | 01-OCT-23:10 | 3094.06 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.11 | 25-OCT-10:53 | 402.05 | 09-OCT-06:00 |
November | 26988.77 | 01-NOV-00:10 | 3094.06 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 530.67 | 24-NOV-06:00 |
December | 26988.77 | 01-DEC-00:10 | 3094.06 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 610.15 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.67 | |||||
Maximum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 201.00 | 708.36 |
Report: PeakSpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2401.70 | 02-JAN-00:10 | 1089.83 | 02-JAN-20:10 | 14912.86 | 01-JAN-07:10 | 22492.83 | 01-JAN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 618.34 | 02-JAN-07:00 |
February | 2401.70 | 01-FEB-00:10 | 1089.83 | 01-FEB-20:10 | 14912.86 | 01-FEB-07:10 | 22492.83 | 01-FEB-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 630.97 | 06-FEB-07:00 |
March | 2401.70 | 01-MAR-00:10 | 1089.83 | 01-MAR-20:10 | 14912.86 | 01-MAR-07:10 | 22492.83 | 01-MAR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 487.33 | 23-MAR-06:00 |
April | 2401.70 | 01-APR-00:10 | 1089.83 | 03-APR-19:10 | 14912.86 | 01-APR-06:10 | 22492.83 | 01-APR-15:09 | 0.00 | 0.00 | 0.00 | 38.35 | 07-APR-13:00 | 357.64 | 03-APR-06:00 |
May | 2401.70 | 01-MAY-00:10 | 1089.83 | 01-MAY-19:10 | 14912.86 | 01-MAY-06:10 | 22492.83 | 01-MAY-15:09 | 0.00 | 0.00 | 0.00 | 86.79 | 30-MAY-13:00 | 300.86 | 01-MAY-06:05 |
June | 2401.70 | 01-JUN-00:10 | 1089.83 | 01-JUN-19:10 | 14912.86 | 01-JUN-06:10 | 22492.83 | 01-JUN-15:09 | 0.00 | 0.00 | 0.00 | 180.11 | 19-JUN-12:00 | 166.60 | 03-JUN-05:00 |
July | 2401.70 | 01-JUL-00:10 | 1089.83 | 03-JUL-19:10 | 14912.86 | 01-JUL-06:10 | 22492.83 | 01-JUL-15:09 | 0.00 | 0.00 | 0.00 | 141.66 | 07-JUL-12:00 | 88.31 | 02-JUL-05:00 |
August | 2401.70 | 01-AUG-00:10 | 1089.83 | 01-AUG-19:10 | 14912.86 | 01-AUG-06:10 | 22492.83 | 01-AUG-15:09 | 0.00 | 0.00 | 0.00 | 140.71 | 24-AUG-15:40 | 141.11 | 08-AUG-05:00 |
September | 2401.70 | 01-SEP-00:10 | 1089.83 | 01-SEP-19:10 | 14912.86 | 01-SEP-06:10 | 22492.83 | 01-SEP-15:09 | 0.00 | 0.00 | 0.00 | 100.60 | 01-SEP-14:00 | 235.70 | 24-SEP-05:34 |
October | 2401.70 | 01-OCT-23:10 | 1089.83 | 02-OCT-19:10 | 14912.86 | 01-OCT-06:10 | 22492.83 | 01-OCT-15:09 | 0.00 | 0.00 | 0.00 | 13.46 | 04-OCT-13:00 | 367.46 | 31-OCT-06:10 |
November | 2401.70 | 01-NOV-00:10 | 1089.83 | 01-NOV-19:10 | 14912.86 | 01-NOV-06:10 | 22492.83 | 01-NOV-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 475.83 | 24-NOV-07:00 |
December | 2401.70 | 01-DEC-00:10 | 1089.83 | 01-DEC-20:10 | 14912.86 | 01-DEC-07:10 | 22492.83 | 01-DEC-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 546.19 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 2401.70 | 1089.83 | 14912.86 | 22492.83 | 0.00 | 0.00 | 0.00 | 0.00 | 88.31 | ||||||
Maximum of Months | 2401.70 | 1089.83 | 14912.86 | 22492.83 | 0.00 | 0.00 | 0.00 | 180.11 | 630.97 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2395.44 | 02-JAN-00:10 | 2371.52 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 563.75 | 02-JAN-05:00 |
February | 2395.44 | 01-FEB-00:10 | 2371.52 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 579.12 | 06-FEB-03:00 |
March | 2395.44 | 01-MAR-00:10 | 2371.52 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 | 27-MAR-16:00 | 427.97 | 23-MAR-06:00 |
April | 2395.44 | 01-APR-00:10 | 2371.52 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.33 | 07-APR-13:00 | 302.25 | 03-APR-06:00 |
May | 2395.44 | 01-MAY-00:10 | 2371.52 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.79 | 30-MAY-13:00 | 236.15 | 01-MAY-05:00 |
June | 2395.44 | 01-JUN-00:10 | 2371.52 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.10 | 19-JUN-12:00 | 145.99 | 03-JUN-03:00 |
July | 2395.44 | 01-JUL-00:10 | 2371.52 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.46 | 07-JUL-12:00 | 70.62 | 02-JUL-03:00 |
August | 2395.44 | 01-AUG-00:10 | 2371.52 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.51 | 24-AUG-15:00 | 120.93 | 08-AUG-05:00 |
September | 2395.44 | 01-SEP-00:10 | 2371.52 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.85 | 01-SEP-14:00 | 185.54 | 30-SEP-01:00 |
October | 2395.44 | 01-OCT-23:10 | 2371.52 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.85 | 25-OCT-10:53 | 304.10 | 09-OCT-06:00 |
November | 2395.44 | 01-NOV-00:10 | 2371.52 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 416.84 | 24-NOV-07:00 |
December | 2395.44 | 01-DEC-00:10 | 2371.52 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 485.22 | 31-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 2395.44 | 2371.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.62 | ||||
Maximum of Months | 2395.44 | 2371.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.10 | 579.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 35196.04 | 19-JAN-20:10 | 17891.83 | 28370.69 | 20227.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 31136.11 | 01-FEB-20:38 | 80513.24 | 127668.10 | 91024.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 22296.35 | 04-MAR-00:46 | 92015.14 | 25218.23 | 25550.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 23040.62 | 12-APR-22:27 | 115018.92 | 47285.09 | 42584.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 21676.78 | 14-MAY-01:02 | 44729.58 | 15761.39 | 15969.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 17414.25 | 22-JUN-18:10 | 53675.50 | 75655.77 | 57488.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 17905.30 | 11-JUL-18:08 | 53675.50 | 75655.77 | 57488.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 19218.40 | 25-AUG-21:00 | 10223.90 | 12609.30 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 22914.88 | 24-SEP-05:17 | 71567.33 | 37828.07 | 34067.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 38083.22 | 27-OCT-21:45 | 115018.92 | 94570.17 | 74522.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 37019.61 | 12-NOV-23:40 | 102239.04 | 47285.09 | 42584.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 36005.90 | 20-DEC-20:21 | 62621.41 | 99297.41 | 70796.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 17414.25 | 10223.90 | 12609.30 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 38083.22 | 115018.92 | 127668.10 | 91024.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4309.33 | 17-JAN-12:30 | 779.69 | 587.01 | 757.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.58 |
February | 3984.85 | 02-FEB-13:28 | 2598.96 | 1956.71 | 2525.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 220.59 |
March | 5327.76 | 29-MAR-13:31 | 1819.27 | 1369.70 | 1768.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 203.79 |
April | 3561.98 | 08-APR-12:30 | 389.84 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.73 |
May | 2938.37 | 14-MAY-01:02 | 4548.18 | 782.68 | 1082.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.79 |
June | 3120.76 | 19-JUN-13:10 | 259.90 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 123.39 | 0.00 |
July | 3322.29 | 08-JUL-12:00 | 389.84 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 94.12 | 0.00 |
August | 4061.75 | 18-AUG-12:40 | 259.90 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 103.70 | 0.00 |
September | 4457.72 | 01-SEP-13:47 | 779.69 | 587.01 | 757.77 | 0.00 | 0.00 | 0.00 | 0.00 | 79.69 | 0.00 |
October | 4470.45 | 04-OCT-12:10 | 259.90 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 5.84 | 0.00 |
November | 4683.14 | 18-NOV-11:01 | 2728.91 | 1369.70 | 1768.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.75 |
December | 5384.71 | 03-DEC-11:07 | 2728.91 | 1643.63 | 2020.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 221.44 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2938.37 | 259.90 | 195.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5384.71 | 4548.18 | 1956.71 | 2525.91 | 0.00 | 0.00 | 0.00 | 0.00 | 123.39 | 221.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2001.30 | 19-JAN-23:50 | 8125.92 | 1631.43 | 2005.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.07 |
February | 2029.14 | 18-FEB-16:28 | 2257.20 | 1132.94 | 1462.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.66 |
March | 2108.21 | 04-MAR-00:15 | 8125.92 | 1087.62 | 1504.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.63 |
April | 2254.22 | 12-APR-22:27 | 13543.20 | 2719.05 | 3342.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.62 |
May | 2165.37 | 14-MAY-01:02 | 5266.80 | 906.35 | 1253.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.41 |
June | 2193.43 | 19-JUN-21:00 | 1203.84 | 725.08 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 0.00 |
July | 2208.17 | 10-JUL-21:00 | 1203.84 | 725.08 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 14.34 | 0.00 |
August | 2272.90 | 04-AUG-21:00 | 1203.84 | 725.08 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 36.16 | 0.00 |
September | 2171.67 | 01-SEP-21:00 | 1203.84 | 725.08 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 12.05 | 0.00 |
October | 3009.21 | 26-OCT-22:05 | 2708.64 | 543.81 | 668.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.55 |
November | 2310.65 | 07-NOV-01:03 | 5417.28 | 543.81 | 835.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.63 |
December | 1911.46 | 03-DEC-23:05 | 2407.68 | 543.81 | 668.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.07 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1911.46 | 1203.84 | 543.81 | 668.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3009.21 | 13543.20 | 2719.05 | 3342.87 | 0.00 | 0.00 | 0.00 | 0.00 | 36.16 | 84.07 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1726.09 | 19-JAN-23:50 | 1718.50 | 2720.79 | 2120.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182.34 |
February | 1401.53 | 18-FEB-15:46 | 954.72 | 3778.88 | 3092.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.80 |
March | 1847.98 | 04-MAR-00:46 | 2291.33 | 2418.48 | 2120.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157.40 |
April | 1992.30 | 12-APR-22:27 | 2864.16 | 4534.65 | 3534.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 173.34 |
May | 1971.56 | 14-MAY-01:02 | 1113.84 | 1511.55 | 1325.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.74 |
June | 1967.22 | 19-JUN-21:00 | 254.59 | 1209.24 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 51.72 | 0.00 |
July | 2209.59 | 10-JUL-20:00 | 222.77 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 45.33 | 0.00 |
August | 2247.29 | 17-AUG-20:00 | 222.77 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 51.44 | 0.00 |
September | 1881.39 | 01-SEP-20:00 | 222.77 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 28.47 | 0.00 |
October | 2139.19 | 26-OCT-22:30 | 2864.16 | 4534.65 | 3534.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 172.39 |
November | 2054.22 | 07-NOV-01:03 | 1145.66 | 906.93 | 883.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.43 |
December | 1650.08 | 03-DEC-23:05 | 509.18 | 906.93 | 706.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.77 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1401.53 | 222.77 | 906.93 | 706.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2247.29 | 2864.16 | 4534.65 | 3534.51 | 0.00 | 0.00 | 0.00 | 0.00 | 51.72 | 182.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 814.59 | 19-JAN-23:50 | 1321.92 | 455.43 | 611.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.20 |
February | 664.79 | 24-FEB-16:21 | 856.80 | 442.80 | 624.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.83 |
March | 882.97 | 04-MAR-00:46 | 1762.56 | 404.83 | 611.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.66 |
April | 940.75 | 12-APR-22:27 | 2203.20 | 759.06 | 1019.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.72 |
May | 934.20 | 14-MAY-01:02 | 856.80 | 253.02 | 382.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.52 |
June | 815.14 | 22-JUN-18:10 | 1028.16 | 1214.49 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 31.70 | 0.00 |
July | 834.80 | 11-JUL-18:08 | 1028.16 | 1214.49 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 17.96 | 0.00 |
August | 874.09 | 04-AUG-21:00 | 195.84 | 202.41 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 49.30 | 0.00 |
September | 818.03 | 01-SEP-18:08 | 1028.16 | 1214.49 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 24.64 | 0.00 |
October | 1012.55 | 26-OCT-22:30 | 2203.20 | 759.06 | 1019.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.29 |
November | 979.73 | 07-NOV-01:03 | 881.28 | 151.82 | 254.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 |
December | 779.49 | 03-DEC-23:05 | 391.68 | 151.81 | 203.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 94.40 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 664.79 | 195.84 | 151.81 | 203.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1012.55 | 2203.20 | 1214.49 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 49.30 | 103.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 50707.70 | 03-JAN-20:46 | 7056.00 | 3572.14 | 45728.01 | 397265.76 | 0.00 | 0.00 | 0.00 | 0.00 | 300.88 |
February | 50701.00 | 01-FEB-20:38 | 6350.40 | 3214.92 | 41155.21 | 357539.19 | 0.00 | 0.00 | 0.00 | 0.00 | 305.23 |
March | 50495.57 | 20-MAR-19:27 | 7056.00 | 3572.14 | 45728.01 | 397265.76 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 |
April | 50163.61 | 13-APR-19:15 | 7056.00 | 3572.14 | 45728.01 | 397265.76 | 0.00 | 0.00 | 0.00 | 0.00 | 310.10 |
May | 38626.70 | 01-MAY-20:20 | 2419.20 | 952.57 | 12996.38 | 112907.11 | 0.00 | 0.00 | 0.00 | 0.00 | 232.26 |
June | 38917.85 | 19-JUN-20:00 | 705.60 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 86.11 | 0.00 |
July | 38870.02 | 10-JUL-20:00 | 705.60 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 61.90 | 0.00 |
August | 39016.04 | 04-AUG-20:00 | 705.60 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 116.67 | 0.00 |
September | 38752.39 | 01-SEP-20:00 | 705.60 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 33.38 | 0.00 |
October | 51194.55 | 27-OCT-20:14 | 8064.00 | 3175.23 | 43321.27 | 376357.04 | 0.00 | 0.00 | 0.00 | 0.00 | 285.57 |
November | 51648.83 | 29-NOV-21:50 | 8064.00 | 3175.23 | 43321.27 | 376357.04 | 0.00 | 0.00 | 0.00 | 0.00 | 332.11 |
December | 51124.76 | 20-DEC-20:26 | 4939.20 | 2500.50 | 32009.60 | 278086.04 | 0.00 | 0.00 | 0.00 | 0.00 | 321.40 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 38626.70 | 705.60 | 357.21 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 51648.83 | 8064.00 | 3572.14 | 45728.01 | 397265.76 | 0.00 | 0.00 | 0.00 | 116.67 | 332.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16682.81 | 17-JAN-12:30 | 10245.60 | 895.64 | 1066.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 395.63 |
February | 16885.66 | 02-FEB-13:28 | 34152.00 | 2985.45 | 3556.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 487.73 |
March | 21774.34 | 29-MAR-13:31 | 23906.40 | 2089.82 | 2489.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 450.59 |
April | 14672.54 | 12-APR-22:27 | 153684.00 | 5873.02 | 4064.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.97 |
May | 13645.87 | 14-MAY-01:02 | 59766.00 | 1957.67 | 1524.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 389.70 |
June | 12165.10 | 19-JUN-21:10 | 15368.40 | 1174.60 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 120.79 | 0.00 |
July | 11999.50 | 10-JUL-21:10 | 15368.40 | 1174.60 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 80.09 | 0.00 |
August | 13747.94 | 19-AUG-13:00 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 85.66 | 0.00 |
September | 15303.21 | 30-SEP-12:40 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.63 |
October | 17885.02 | 08-OCT-09:30 | 25614.00 | 1074.76 | 1219.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 454.97 |
November | 20025.62 | 18-NOV-11:01 | 35859.60 | 2089.82 | 2489.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 480.15 |
December | 22336.11 | 17-DEC-10:08 | 42690.00 | 1791.27 | 2032.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 421.36 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 11999.50 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22336.11 | 153684.00 | 5873.02 | 4064.31 | 0.00 | 0.00 | 0.00 | 0.00 | 120.79 | 487.73 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 45976.30 | 19-JAN-22:50 | 91245.96 | 13686.91 | 14779.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1456.82 |
February | 41669.74 | 18-FEB-16:28 | 76038.30 | 13259.20 | 18474.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1275.76 |
March | 60311.43 | 28-MAR-21:57 | 364983.84 | 54747.65 | 59119.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1291.74 |
April | 65143.00 | 11-APR-21:49 | 456229.80 | 68434.56 | 73899.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1227.11 |
May | 52077.75 | 16-MAY-04:15 | 364983.84 | 18249.22 | 25336.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1193.00 |
June | 42272.40 | 19-JUN-21:10 | 45622.98 | 6843.46 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 344.97 | 0.00 |
July | 42627.21 | 10-JUL-21:10 | 45622.98 | 6843.46 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 228.67 | 0.00 |
August | 43844.34 | 04-AUG-21:10 | 45622.98 | 6843.46 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 546.00 | 0.00 |
September | 42640.86 | 01-SEP-21:10 | 45622.98 | 6843.46 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 190.05 | 0.00 |
October | 72518.94 | 21-OCT-05:42 | 212907.24 | 20530.37 | 25336.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1125.64 |
November | 65370.53 | 06-NOV-22:27 | 456229.80 | 68434.56 | 73899.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1277.56 |
December | 45118.47 | 03-DEC-21:50 | 162215.04 | 27373.82 | 29559.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1343.42 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 41669.74 | 45622.98 | 6843.46 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 72518.94 | 456229.80 | 68434.56 | 73899.43 | 0.00 | 0.00 | 0.00 | 0.00 | 546.00 | 1456.82 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2997.06 | 19-JAN-16:01 | 777.60 | 274.41 | 547.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 102.24 |
February | 3011.53 | 02-FEB-16:01 | 680.40 | 240.11 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.11 |
March | 3105.53 | 07-MAR-16:01 | 874.80 | 308.71 | 616.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.33 |
April | 3272.28 | 10-APR-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.75 |
May | 3320.49 | 27-MAY-15:02 | 324.00 | 242.57 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.77 |
June | 3353.35 | 15-JUN-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 25.98 | 0.00 |
July | 3393.51 | 13-JUL-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 49.73 | 0.00 |
August | 3433.14 | 21-AUG-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 49.77 | 0.00 |
September | 3440.34 | 07-SEP-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 25.17 | 0.00 |
October | 3098.24 | 04-OCT-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 5.24 | 0.00 |
November | 3073.32 | 02-NOV-15:01 | 680.40 | 240.11 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.85 |
December | 2977.34 | 17-DEC-16:01 | 378.00 | 282.99 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.68 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2977.34 | 324.00 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3440.34 | 874.80 | 308.71 | 616.35 | 0.00 | 0.00 | 0.00 | 0.00 | 49.77 | 133.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1748.28 | 17-JAN-16:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.87 |
February | 2641.80 | 20-FEB-16:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.86 |
March | 2986.36 | 07-MAR-16:01 | 874.80 | 308.68 | 616.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.71 |
April | 3151.99 | 10-APR-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.21 |
May | 3222.78 | 27-MAY-15:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.69 |
June | 3260.17 | 15-JUN-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 25.95 | 0.00 |
July | 3282.58 | 07-JUL-18:02 | 831.60 | 654.11 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 30.00 | 0.00 |
August | 3297.62 | 12-AUG-15:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 40.31 | 0.00 |
September | 3208.28 | 07-SEP-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 25.49 | 0.00 |
October | 3140.85 | 03-OCT-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 3.64 | 0.00 |
November | 2932.76 | 03-NOV-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.82 |
December | 1189.52 | 17-DEC-19:03 | 1170.00 | 1224.91 | 1290.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.27 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1189.52 | 324.00 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3297.62 | 1170.00 | 1224.91 | 1290.50 | 0.00 | 0.00 | 0.00 | 0.00 | 40.31 | 105.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 198.05 | 19-JAN-14:40 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.54 |
February | 318.22 | 20-FEB-13:23 | 0.00 | 101.63 | 299.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.27 |
March | 486.35 | 03-MAR-13:30 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.13 |
April | 633.66 | 08-APR-12:30 | 0.00 | 25.41 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 | 0.00 |
May | 509.30 | 30-MAY-12:50 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 12.24 | 0.00 |
June | 536.34 | 19-JUN-13:20 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 20.95 | 0.00 |
July | 563.59 | 10-JUL-13:10 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 16.50 | 0.00 |
August | 698.25 | 30-AUG-13:00 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 7.20 | 0.00 |
September | 742.82 | 30-SEP-12:40 | 0.00 | 25.41 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.79 |
October | 796.57 | 04-OCT-12:10 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 2.13 | 0.00 |
November | 648.83 | 02-NOV-13:00 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.24 |
December | 492.07 | 17-DEC-13:40 | 0.00 | 50.81 | 149.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.98 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 198.05 | 0.00 | 21.56 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 796.57 | 0.00 | 101.63 | 299.27 | 0.00 | 0.00 | 0.00 | 0.00 | 20.95 | 28.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 602.00 | 03-JAN-19:03 | 1386.00 | 685.40 | 1264.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.73 |
February | 580.06 | 01-FEB-19:03 | 1386.00 | 685.40 | 1264.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.24 |
March | 806.93 | 28-MAR-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.09 |
April | 927.76 | 08-APR-15:02 | 324.00 | 152.48 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.39 |
May | 996.65 | 29-MAY-15:02 | 324.00 | 152.48 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 5.03 | 0.00 |
June | 1011.01 | 20-JUN-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 7.57 | 0.00 |
July | 1016.69 | 11-JUL-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 10.11 | 0.00 |
August | 1015.23 | 22-AUG-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 13.03 | 0.00 |
September | 993.14 | 01-SEP-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 13.79 | 0.00 |
October | 890.25 | 04-OCT-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.54 | 0.00 |
November | 807.11 | 05-NOV-08:62 | 270.00 | 215.63 | 799.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.50 |
December | 466.82 | 29-DEC-19:04 | 970.20 | 479.78 | 885.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.17 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 466.82 | 270.00 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1016.69 | 1386.00 | 685.40 | 1264.50 | 0.00 | 0.00 | 0.00 | 0.00 | 13.79 | 31.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2446.74 | 19-JAN-09:01 | 252.00 | 377.32 | 792.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.08 |
February | 2666.67 | 25-FEB-09:01 | 378.00 | 480.22 | 1143.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.21 |
March | 2854.21 | 07-MAR-09:01 | 360.00 | 539.02 | 1132.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.84 |
April | 2931.70 | 10-APR-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.27 |
May | 3003.40 | 31-MAY-08:62 | 216.00 | 323.41 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 2.25 | 0.00 |
June | 3112.29 | 23-JUN-08:62 | 216.00 | 323.41 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 26.81 | 0.00 |
July | 3082.24 | 13-JUL-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 50.83 | 0.00 |
August | 3112.89 | 01-AUG-08:62 | 216.00 | 323.41 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 28.13 | 0.00 |
September | 3101.04 | 07-SEP-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 26.50 | 0.00 |
October | 2969.61 | 03-OCT-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 0.00 |
November | 2807.85 | 02-NOV-15:01 | 680.40 | 240.11 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.61 |
December | 2655.02 | 20-DEC-09:01 | 360.00 | 539.02 | 1132.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.44 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2446.74 | 216.00 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3112.89 | 680.40 | 539.02 | 1143.15 | 0.00 | 0.00 | 0.00 | 0.00 | 50.83 | 181.21 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1106.98 | 26-JAN-09:03 | 252.00 | 377.27 | 792.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 152.13 |
February | 2146.51 | 19-FEB-09:01 | 378.00 | 480.16 | 1143.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.03 |
March | 2683.05 | 03-MAR-09:02 | 216.00 | 323.38 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.25 |
April | 2830.22 | 08-APR-15:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.07 |
May | 2985.42 | 31-MAY-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 21.43 | 0.00 |
June | 3030.77 | 23-JUN-08:62 | 216.00 | 323.38 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 26.64 | 0.00 |
July | 3043.27 | 14-JUL-08:62 | 216.00 | 323.38 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 34.18 | 0.00 |
August | 3069.06 | 02-AUG-08:62 | 216.00 | 323.38 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 37.82 | 0.00 |
September | 3018.60 | 01-SEP-08:61 | 252.00 | 377.27 | 792.74 | 0.00 | 0.00 | 0.00 | 0.00 | 22.43 | 0.00 |
October | 2732.24 | 02-OCT-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 0.00 |
November | 2452.06 | 06-NOV-09:02 | 216.00 | 323.38 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.38 |
December | 1035.01 | 09-DEC-09:03 | 378.00 | 480.16 | 1143.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.87 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1035.01 | 216.00 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3069.06 | 583.20 | 480.16 | 1143.02 | 0.00 | 0.00 | 0.00 | 0.00 | 37.82 | 152.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2752.87 | 19-JAN-23:50 | 13580.14 | 4481.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.55 |
February | 3028.69 | 18-FEB-16:28 | 3772.26 | 3112.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.57 |
March | 2988.01 | 04-MAR-00:46 | 18106.85 | 3983.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 121.74 |
April | 3303.42 | 12-APR-22:27 | 22633.56 | 7469.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.07 |
May | 3175.12 | 14-MAY-01:02 | 8801.94 | 2489.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.82 |
June | 2791.10 | 22-JUN-18:10 | 10562.33 | 11950.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.28 | 0.00 |
July | 3062.38 | 10-JUL-18:13 | 5281.16 | 5975.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.12 | 0.00 |
August | 3145.04 | 22-AUG-19:00 | 3520.78 | 3983.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.87 | 0.00 |
September | 2808.28 | 01-SEP-18:08 | 10562.33 | 11950.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.60 | 0.00 |
October | 3447.02 | 26-OCT-22:30 | 22633.56 | 7469.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.88 |
November | 3350.37 | 07-NOV-01:03 | 9053.42 | 1493.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.07 |
December | 2645.78 | 03-DEC-23:05 | 4023.74 | 1493.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 2645.78 | 3520.78 | 1493.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3447.02 | 22633.56 | 11950.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.12 | 139.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3137.36 | 19-JAN-16:01 | 777.60 | 274.41 | 547.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 102.71 |
February | 3140.42 | 02-FEB-16:01 | 680.40 | 240.11 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.32 |
March | 3248.98 | 07-MAR-16:01 | 874.80 | 308.71 | 616.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.72 |
April | 3420.07 | 10-APR-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.06 |
May | 3476.98 | 27-MAY-15:02 | 324.00 | 242.57 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.21 |
June | 3589.54 | 19-JUN-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 66.62 | 0.00 |
July | 3569.84 | 07-JUL-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 58.53 | 0.00 |
August | 3601.34 | 01-AUG-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 50.44 | 0.00 |
September | 3556.16 | 07-SEP-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 24.64 | 0.00 |
October | 3364.89 | 04-OCT-15:02 | 583.20 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 5.01 | 0.00 |
November | 3205.02 | 02-NOV-15:01 | 680.40 | 240.11 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.04 |
December | 3121.90 | 17-DEC-16:01 | 378.00 | 282.99 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.36 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3121.90 | 324.00 | 205.81 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3601.34 | 874.80 | 308.71 | 616.35 | 0.00 | 0.00 | 0.00 | 0.00 | 66.62 | 133.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1034.39 | 20-JAN-16:02 | 972.00 | 342.97 | 684.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.53 |
February | 2184.20 | 20-FEB-16:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.51 |
March | 3099.07 | 07-MAR-16:01 | 874.80 | 308.68 | 616.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.62 |
April | 3284.36 | 10-APR-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.47 |
May | 3366.92 | 27-MAY-15:02 | 324.00 | 242.54 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.11 |
June | 3362.85 | 02-JUN-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 |
July | 3478.61 | 07-JUL-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 0.00 |
August | 3477.21 | 04-AUG-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 54.15 | 0.00 |
September | 3318.77 | 11-SEP-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.53 |
October | 3289.54 | 03-OCT-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 3.36 | 0.00 |
November | 3013.85 | 03-NOV-15:02 | 583.20 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.99 |
December | 1166.15 | 08-DEC-16:03 | 680.40 | 240.08 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.94 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1034.39 | 324.00 | 205.78 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3478.61 | 972.00 | 342.97 | 684.76 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 110.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1709.72 | 20-JAN-16:01 | 972.00 | 215.63 | 670.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.33 |
February | 1693.98 | 02-FEB-16:01 | 680.40 | 150.94 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.29 |
March | 1713.89 | 07-MAR-16:01 | 874.80 | 194.07 | 603.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.00 |
April | 1783.54 | 10-APR-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.67 |
May | 1804.61 | 27-MAY-15:02 | 324.00 | 152.48 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.44 |
June | 1843.16 | 15-JUN-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 12.98 | 0.00 |
July | 1845.88 | 16-JUL-15:02 | 324.00 | 152.48 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 | 0.00 |
August | 1896.18 | 18-AUG-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 33.26 | 0.00 |
September | 1863.40 | 06-SEP-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 10.59 | 0.00 |
October | 1836.37 | 04-OCT-15:02 | 583.20 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 2.28 | 0.00 |
November | 1718.75 | 02-NOV-15:01 | 680.40 | 150.94 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.36 |
December | 1692.27 | 17-DEC-16:01 | 378.00 | 177.90 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.44 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1692.27 | 324.00 | 129.38 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1896.18 | 972.00 | 215.63 | 670.96 | 0.00 | 0.00 | 0.00 | 0.00 | 33.26 | 69.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 37322.73 | 19-JAN-23:50 | 161932.61 | 6188.11 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 330.24 |
February | 27402.85 | 01-FEB-19:50 | 209912.64 | 27502.72 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 322.58 |
March | 33084.01 | 11-MAR-23:11 | 146938.85 | 7219.46 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 302.52 |
April | 34557.15 | 12-APR-22:27 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 297.13 |
May | 30965.00 | 16-MAY-03:37 | 161932.61 | 2062.70 | 13495.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 273.09 |
June | 23718.41 | 19-JUN-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 72.81 | 0.00 |
July | 23468.51 | 10-JUL-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 48.26 | 0.00 |
August | 23825.34 | 04-AUG-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 110.58 | 0.00 |
September | 24860.44 | 24-SEP-05:36 | 104956.32 | 5156.76 | 28116.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 245.86 |
October | 36520.12 | 26-OCT-22:59 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 289.07 |
November | 38099.89 | 06-NOV-23:42 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 289.93 |
December | 30975.27 | 04-DEC-23:34 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 284.85 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 23468.51 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 38099.89 | 269887.68 | 27502.72 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 110.58 | 330.24 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 39382.16 | 19-JAN-23:50 | 161932.61 | 6188.11 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 332.05 |
February | 31706.19 | 01-FEB-19:38 | 209912.64 | 27502.72 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 321.40 |
March | 34803.46 | 11-MAR-23:11 | 146938.85 | 7219.46 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 303.42 |
April | 37689.71 | 12-APR-22:27 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.57 |
May | 32920.33 | 15-MAY-05:47 | 62973.79 | 3300.33 | 16869.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 268.63 |
June | 24925.96 | 19-JUN-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 72.78 | 0.00 |
July | 24634.72 | 10-JUL-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 48.24 | 0.00 |
August | 24997.59 | 04-AUG-21:20 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 110.56 | 0.00 |
September | 27452.14 | 24-SEP-05:36 | 104956.32 | 5156.76 | 28116.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.04 |
October | 37121.84 | 26-OCT-22:59 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.93 |
November | 36241.84 | 06-NOV-23:42 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 291.65 |
December | 32732.11 | 04-DEC-23:34 | 269887.68 | 10313.52 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 286.59 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 24634.72 | 26988.77 | 2062.70 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39382.16 | 269887.68 | 27502.72 | 67479.03 | 0.00 | 0.00 | 0.00 | 0.00 | 110.56 | 332.05 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 38400.91 | 19-JAN-23:50 | 14410.22 | 2179.66 | 89477.13 | 22492.83 | 0.00 | 0.00 | 0.00 | 0.00 | 301.65 |
February | 37508.55 | 18-FEB-16:28 | 4002.84 | 1513.65 | 74564.28 | 112464.16 | 0.00 | 0.00 | 0.00 | 0.00 | 258.46 |
March | 36665.68 | 29-MAR-15:51 | 9339.96 | 2119.12 | 104389.99 | 157449.82 | 0.00 | 0.00 | 0.00 | 0.00 | 288.36 |
April | 35598.79 | 19-APR-09:21 | 3735.98 | 2119.12 | 104389.99 | 131208.19 | 0.00 | 0.00 | 0.00 | 0.00 | 243.51 |
May | 32986.96 | 15-MAY-05:54 | 18679.92 | 4843.69 | 125511.30 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 241.90 |
June | 32864.94 | 22-JUN-18:10 | 11207.95 | 5812.43 | 89477.13 | 89971.33 | 0.00 | 0.00 | 0.00 | 65.29 | 0.00 |
July | 32413.64 | 11-JUL-18:08 | 11207.95 | 5812.43 | 89477.13 | 89971.33 | 0.00 | 0.00 | 0.00 | 38.28 | 0.00 |
August | 34838.51 | 24-AUG-16:57 | 5337.12 | 1210.92 | 59651.42 | 89971.33 | 0.00 | 0.00 | 0.00 | 119.63 | 0.00 |
September | 31476.78 | 01-SEP-18:08 | 11207.95 | 5812.43 | 89477.13 | 89971.33 | 0.00 | 0.00 | 0.00 | 51.49 | 0.00 |
October | 35655.36 | 27-OCT-07:40 | 8539.39 | 3874.95 | 119302.85 | 119961.77 | 0.00 | 0.00 | 0.00 | 0.00 | 283.23 |
November | 40163.50 | 30-NOV-13:52 | 3202.27 | 1816.39 | 89477.13 | 89971.33 | 0.00 | 0.00 | 0.00 | 0.00 | 266.77 |
December | 36135.94 | 04-DEC-17:11 | 9339.96 | 2119.12 | 104389.99 | 157449.82 | 0.00 | 0.00 | 0.00 | 0.00 | 270.96 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 31476.78 | 3202.27 | 1210.92 | 59651.42 | 22492.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 40163.50 | 18679.92 | 5812.43 | 125511.30 | 157449.82 | 0.00 | 0.00 | 0.00 | 119.63 | 301.65 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5736.76 | 19-JAN-12:07 | 5323.20 | 6587.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.71 |
February | 6291.45 | 18-FEB-16:28 | 3992.40 | 3293.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 237.29 |
March | 6099.13 | 04-MAR-00:46 | 19163.52 | 4216.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.74 |
April | 6496.83 | 12-APR-22:27 | 23954.40 | 7905.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 233.82 |
May | 6403.05 | 14-MAY-01:02 | 9315.60 | 2635.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 210.60 |
June | 6746.65 | 19-JUN-14:10 | 798.48 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.52 | 0.00 |
July | 7130.15 | 08-JUL-12:00 | 798.48 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.44 | 0.00 |
August | 7302.76 | 16-AUG-12:50 | 532.32 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.28 | 0.00 |
September | 6681.40 | 01-SEP-14:10 | 798.48 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.70 | 0.00 |
October | 6812.62 | 26-OCT-22:30 | 23954.40 | 7905.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 227.35 |
November | 6638.32 | 07-NOV-01:03 | 9581.76 | 1581.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.65 |
December | 5329.29 | 03-DEC-23:05 | 4258.56 | 1581.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 224.07 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 5329.29 | 532.32 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 7302.76 | 23954.40 | 7905.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.52 | 237.29 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.383214E+12 | 257030.83 | 19-JAN-20:10 | 0.633424E+12 | 552115.21 | 14-JAN-17:10 |
February | 0.345694E+12 | 242843.52 | 22-FEB-20:19 | 0.564911E+12 | 560006.54 | 05-FEB-19:10 |
March | 0.384867E+12 | 268662.09 | 27-MAR-18:10 | 0.522172E+12 | 460153.02 | 05-MAR-18:00 |
April | 0.386132E+12 | 329039.52 | 07-APR-19:10 | 0.464783E+12 | 507412.10 | 01-APR-20:30 |
May | 0.443119E+12 | 348131.01 | 31-MAY-19:19 | 0.425535E+12 | 351763.38 | 04-MAY-17:40 |
June | 0.587270E+12 | 419870.13 | 19-JUN-19:30 | 0.388413E+12 | 352394.90 | 01-JUN-17:10 |
July | 0.714879E+12 | 419134.24 | 20-JUL-19:30 | 0.392558E+12 | 348386.46 | 11-JUL-17:10 |
August | 0.677975E+12 | 454905.91 | 04-AUG-19:10 | 0.391045E+12 | 350492.12 | 30-AUG-17:00 |
September | 0.531760E+12 | 414171.56 | 13-SEP-19:00 | 0.384711E+12 | 347960.57 | 26-SEP-17:19 |
October | 0.451829E+12 | 345415.26 | 05-OCT-19:10 | 0.429285E+12 | 391240.28 | 27-OCT-16:49 |
November | 0.376675E+12 | 248502.09 | 07-NOV-20:49 | 0.494796E+12 | 433154.92 | 29-NOV-19:10 |
December | 0.387409E+12 | 244560.10 | 18-DEC-20:10 | 0.556950E+12 | 520832.70 | 31-DEC-19:10 |
Annual Sum or Average | 0.567082E+13 | 0.564858E+13 | ||||
Minimum of Months | 0.345694E+12 | 242843.52 | 0.384711E+12 | 347960.57 | ||
Maximum of Months | 0.714879E+12 | 454905.91 | 0.633424E+12 | 560006.54 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.654865E+11 | 0.251006E+11 | 0.148212E+12 | 0.553310E+11 | 0.438231E+11 | 0.513403E+10 | 0.00 | 0.162124E+10 | 0.00 | 0.00 | 0.256175E+11 | 0.770508E+10 | 0.00 |
February | 0.590035E+11 | 0.210500E+11 | 0.133859E+12 | 0.499764E+11 | 0.390134E+11 | 0.515526E+10 | 0.00 | 0.203932E+10 | 0.00 | 0.00 | 0.239727E+11 | 0.696282E+10 | 0.00 |
March | 0.652066E+11 | 0.210778E+11 | 0.148223E+12 | 0.553337E+11 | 0.441630E+11 | 0.738505E+10 | 0.00 | 0.624398E+10 | 0.00 | 0.00 | 0.243038E+11 | 0.770329E+10 | 0.00 |
April | 0.628376E+11 | 0.181673E+11 | 0.143397E+12 | 0.535455E+11 | 0.438299E+11 | 0.970644E+10 | 0.00 | 0.256396E+11 | 0.00 | 0.00 | 0.164646E+11 | 0.746526E+10 | 0.00 |
May | 0.647884E+11 | 0.167955E+11 | 0.148223E+12 | 0.553319E+11 | 0.479710E+11 | 0.137228E+11 | 0.00 | 0.754869E+11 | 0.00 | 0.00 | 0.780028E+10 | 0.770467E+10 | 0.00 |
June | 0.626255E+11 | 0.152105E+11 | 0.143446E+12 | 0.535480E+11 | 0.508598E+11 | 0.146754E+11 | 0.00 | 0.220917E+12 | 0.00 | 0.00 | 0.133494E+11 | 0.745684E+10 | 0.00 |
July | 0.646311E+11 | 0.161837E+11 | 0.148174E+12 | 0.553289E+11 | 0.557770E+11 | 0.159983E+11 | 0.00 | 0.320858E+12 | 0.00 | 0.00 | 0.248716E+11 | 0.771256E+10 | 0.00 |
August | 0.649397E+11 | 0.178707E+11 | 0.148234E+12 | 0.553335E+11 | 0.575501E+11 | 0.156882E+11 | 0.00 | 0.287349E+12 | 0.00 | 0.00 | 0.179484E+11 | 0.770429E+10 | 0.00 |
September | 0.629683E+11 | 0.194186E+11 | 0.143408E+12 | 0.535457E+11 | 0.504823E+11 | 0.142782E+11 | 0.00 | 0.165822E+12 | 0.00 | 0.00 | 0.920946E+10 | 0.746645E+10 | 0.00 |
October | 0.652880E+11 | 0.223847E+11 | 0.148201E+12 | 0.553307E+11 | 0.496513E+11 | 0.132388E+11 | 0.00 | 0.731971E+11 | 0.00 | 0.00 | 0.115469E+11 | 0.770317E+10 | 0.00 |
November | 0.633458E+11 | 0.237009E+11 | 0.143462E+12 | 0.535468E+11 | 0.443463E+11 | 0.768113E+10 | 0.00 | 0.697494E+10 | 0.00 | 0.00 | 0.211105E+11 | 0.744912E+10 | 0.00 |
December | 0.654211E+11 | 0.255918E+11 | 0.148174E+12 | 0.553297E+11 | 0.442511E+11 | 0.661037E+10 | 0.00 | 0.304899E+10 | 0.00 | 0.00 | 0.260790E+11 | 0.771321E+10 | 0.00 |
Annual Sum or Average | 0.766542E+12 | 0.242552E+12 | 0.174501E+13 | 0.651482E+12 | 0.571718E+12 | 0.129274E+12 | 0.00 | 0.118920E+13 | 0.00 | 0.00 | 0.222274E+12 | 0.907468E+11 | 0.00 |
Minimum of Months | 0.590035E+11 | 0.152105E+11 | 0.133859E+12 | 0.499764E+11 | 0.390134E+11 | 0.513403E+10 | 0.00 | 0.162124E+10 | 0.00 | 0.00 | 0.780028E+10 | 0.696282E+10 | 0.00 |
Maximum of Months | 0.654865E+11 | 0.255918E+11 | 0.148234E+12 | 0.553337E+11 | 0.575501E+11 | 0.159983E+11 | 0.00 | 0.320858E+12 | 0.00 | 0.00 | 0.260790E+11 | 0.771321E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [J] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.151918E+12 | 0.00 | 0.195695E+12 | 0.00 | 0.285810E+12 | 0.00 | 0.00 |
February | 0.137204E+12 | 0.00 | 0.167721E+12 | 0.00 | 0.259987E+12 | 0.00 | 0.00 |
March | 0.152024E+12 | 0.00 | 0.866544E+11 | 0.00 | 0.283494E+12 | 0.00 | 0.00 |
April | 0.146956E+12 | 0.00 | 0.530593E+11 | 0.00 | 0.264768E+12 | 0.00 | 0.00 |
May | 0.151978E+12 | 0.00 | 0.125408E+11 | 0.00 | 0.261016E+12 | 0.00 | 0.00 |
June | 0.147114E+12 | 0.00 | 0.398180E+09 | 0.00 | 0.240901E+12 | 0.00 | 0.00 |
July | 0.151820E+12 | 0.00 | 92785785.25 | 0.00 | 0.240645E+12 | 0.00 | 0.00 |
August | 0.152039E+12 | 0.00 | 0.467698E+09 | 0.00 | 0.238539E+12 | 0.00 | 0.00 |
September | 0.146971E+12 | 0.00 | 0.255879E+10 | 0.00 | 0.235181E+12 | 0.00 | 0.00 |
October | 0.151903E+12 | 0.00 | 0.244168E+11 | 0.00 | 0.252965E+12 | 0.00 | 0.00 |
November | 0.147091E+12 | 0.00 | 0.906633E+11 | 0.00 | 0.257041E+12 | 0.00 | 0.00 |
December | 0.151820E+12 | 0.00 | 0.127540E+12 | 0.00 | 0.277590E+12 | 0.00 | 0.00 |
Annual Sum or Average | 0.178884E+13 | 0.00 | 0.761808E+12 | 0.00 | 0.309794E+13 | 0.00 | 0.00 |
Minimum of Months | 0.137204E+12 | 0.00 | 92785785.25 | 0.00 | 0.235181E+12 | 0.00 | 0.00 |
Maximum of Months | 0.152039E+12 | 0.00 | 0.195695E+12 | 0.00 | 0.285810E+12 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 62892.57 | 02-JAN-20:10 | 15448.40 | 01-JAN-00:10 | 89475.41 | 02-JAN-07:10 | 39726.11 | 02-JAN-07:19 | 44313.79 | 19-JAN-21:40 | 5748.37 | 11-JAN-16:30 | 0.00 | 01-JAN-00:10 |
February | 62892.57 | 01-FEB-20:10 | 15448.40 | 01-FEB-00:10 | 89475.41 | 01-FEB-07:10 | 39726.11 | 01-FEB-07:19 | 26701.78 | 20-FEB-15:09 | 5849.27 | 01-FEB-16:00 | 0.00 | 01-FEB-00:10 |
March | 62892.57 | 01-MAR-20:10 | 15448.40 | 01-MAR-00:10 | 89475.41 | 01-MAR-07:10 | 39726.11 | 13-MAR-06:19 | 32007.54 | 07-MAR-20:30 | 5778.28 | 12-MAR-09:00 | 0.00 | 01-MAR-00:10 |
April | 62892.57 | 03-APR-19:10 | 15448.40 | 01-APR-00:10 | 89475.41 | 03-APR-06:10 | 39725.08 | 18-APR-06:19 | 36645.99 | 17-APR-22:30 | 5988.16 | 07-APR-15:09 | 0.00 | 01-APR-00:10 |
May | 62892.57 | 01-MAY-19:10 | 15448.40 | 01-MAY-00:10 | 89475.41 | 01-MAY-06:10 | 39725.08 | 04-MAY-06:19 | 33559.97 | 31-MAY-21:10 | 6450.80 | 31-MAY-18:10 | 0.00 | 01-MAY-00:10 |
June | 62892.57 | 01-JUN-19:19 | 15448.40 | 01-JUN-00:10 | 89475.41 | 01-JUN-06:10 | 39724.49 | 16-JUN-06:19 | 35685.13 | 19-JUN-21:10 | 7648.61 | 24-JUN-18:10 | 0.00 | 01-JUN-00:10 |
July | 62892.57 | 03-JUL-19:30 | 15448.40 | 01-JUL-00:10 | 89475.41 | 03-JUL-06:10 | 39724.92 | 24-JUL-06:19 | 37431.79 | 10-JUL-21:10 | 7478.12 | 05-JUL-19:10 | 0.00 | 01-JUL-00:10 |
August | 62892.57 | 01-AUG-19:10 | 15448.40 | 01-AUG-00:10 | 89475.41 | 01-AUG-06:10 | 39724.92 | 16-AUG-06:19 | 40092.66 | 18-AUG-21:10 | 7418.06 | 11-AUG-20:00 | 0.00 | 01-AUG-00:10 |
September | 62892.57 | 01-SEP-19:10 | 15448.40 | 01-SEP-00:10 | 89475.41 | 01-SEP-06:10 | 39725.67 | 27-SEP-06:19 | 40471.82 | 01-SEP-20:10 | 7363.74 | 07-SEP-19:00 | 0.00 | 01-SEP-00:10 |
October | 62892.57 | 02-OCT-19:10 | 15448.40 | 01-OCT-00:10 | 89475.41 | 02-OCT-06:10 | 39726.11 | 06-OCT-06:19 | 35183.30 | 28-OCT-20:30 | 6286.07 | 05-OCT-15:30 | 0.00 | 01-OCT-00:10 |
November | 62892.57 | 01-NOV-19:10 | 15448.40 | 01-NOV-00:10 | 89475.41 | 01-NOV-06:10 | 39726.11 | 01-NOV-06:19 | 33700.77 | 05-NOV-21:00 | 5807.90 | 01-NOV-06:49 | 0.00 | 01-NOV-00:10 |
December | 62892.57 | 01-DEC-20:10 | 15448.40 | 01-DEC-00:10 | 89475.41 | 01-DEC-07:10 | 39726.11 | 01-DEC-07:19 | 36567.30 | 17-DEC-22:10 | 5839.50 | 20-DEC-16:40 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 62892.57 | 15448.40 | 89475.41 | 39724.49 | 26701.78 | 5748.37 | 0.00 | |||||||
Maximum of Months | 62892.57 | 15448.40 | 89475.41 | 39726.11 | 44313.79 | 7648.61 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 7373.56 | 17-JAN-16:10 | 0.00 | 0.00 | 9938.94 | 01-JAN-00:20 | 4738.31 | 03-JAN-19:40 | 0.00 |
February | 10072.28 | 02-FEB-16:10 | 0.00 | 0.00 | 9938.94 | 01-FEB-00:20 | 4738.33 | 07-FEB-07:19 | 0.00 |
March | 71617.71 | 27-MAR-15:00 | 0.00 | 0.00 | 9938.94 | 01-MAR-00:20 | 4738.50 | 10-MAR-19:10 | 0.00 |
April | 103942.73 | 07-APR-15:09 | 0.00 | 0.00 | 9938.94 | 01-APR-00:10 | 4738.50 | 18-APR-06:19 | 0.00 |
May | 120195.50 | 31-MAY-15:20 | 0.00 | 0.00 | 9938.94 | 01-MAY-00:20 | 4738.30 | 01-MAY-18:10 | 0.00 |
June | 188096.86 | 19-JUN-18:10 | 0.00 | 0.00 | 9938.94 | 01-JUN-10:30 | 4738.09 | 05-JUN-18:10 | 0.00 |
July | 180460.84 | 20-JUL-15:20 | 0.00 | 0.00 | 9938.94 | 01-JUL-06:00 | 4738.04 | 10-JUL-06:10 | 0.00 |
August | 203778.65 | 16-AUG-15:20 | 0.00 | 0.00 | 9938.94 | 01-AUG-00:10 | 4738.01 | 07-AUG-06:10 | 0.00 |
September | 164209.56 | 07-SEP-20:40 | 0.00 | 0.00 | 9938.94 | 01-SEP-00:10 | 4738.31 | 08-SEP-06:19 | 0.00 |
October | 119526.77 | 04-OCT-15:09 | 0.00 | 0.00 | 9938.94 | 01-OCT-00:10 | 4738.33 | 30-OCT-18:10 | 0.00 |
November | 46390.21 | 04-NOV-11:50 | 0.00 | 0.00 | 9938.94 | 01-NOV-00:10 | 4738.56 | 10-NOV-19:10 | 0.00 |
December | 14071.44 | 17-DEC-14:30 | 0.00 | 0.00 | 9938.94 | 01-DEC-00:10 | 4738.32 | 04-DEC-19:10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 7373.56 | 0.00 | 0.00 | 9938.94 | 4738.01 | 0.00 | |||
Maximum of Months | 203778.65 | 0.00 | 0.00 | 9938.94 | 4738.56 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 257030.83 | 19-JAN-20:10 | 62892.57 | 88772.42 | 15448.40 | 32151.31 | 34110.99 | 5617.48 | 0.00 | 1838.40 | 0.00 |
February | 242843.52 | 22-FEB-20:19 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 20060.42 | 5370.69 | 0.00 | 1798.74 | 0.00 |
March | 268662.09 | 27-MAR-18:10 | 55920.94 | 79417.81 | 15448.40 | 31836.58 | 20972.57 | 5393.22 | 0.00 | 52522.42 | 0.00 |
April | 329039.52 | 07-APR-19:10 | 62892.57 | 88772.42 | 15448.40 | 32151.31 | 26488.88 | 5965.29 | 0.00 | 90059.03 | 0.00 |
May | 348131.01 | 31-MAY-19:19 | 62892.57 | 88772.42 | 15448.40 | 32158.99 | 27719.80 | 6082.12 | 0.00 | 100562.95 | 0.00 |
June | 419870.13 | 19-JUN-19:30 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 30724.18 | 6592.93 | 0.00 | 166856.77 | 0.00 |
July | 419134.24 | 20-JUL-19:30 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 29641.61 | 7061.81 | 0.00 | 166922.73 | 0.00 |
August | 454905.91 | 04-AUG-19:10 | 62892.57 | 88772.42 | 15448.40 | 32150.62 | 33670.79 | 7013.13 | 0.00 | 199615.47 | 0.00 |
September | 414171.56 | 13-SEP-19:00 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 29589.02 | 7293.30 | 0.00 | 161861.30 | 0.00 |
October | 345415.26 | 05-OCT-19:10 | 62892.57 | 88772.42 | 15448.40 | 32151.31 | 27175.26 | 6088.86 | 0.00 | 98424.51 | 0.00 |
November | 248502.09 | 07-NOV-20:49 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 24591.17 | 5271.67 | 0.00 | 3869.75 | 0.00 |
December | 244560.10 | 18-DEC-20:10 | 62892.57 | 88772.42 | 15448.40 | 32151.31 | 21753.26 | 5366.85 | 0.00 | 2011.36 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 242843.52 | 55920.94 | 79417.81 | 15448.40 | 31836.58 | 20060.42 | 5271.67 | 0.00 | 1798.74 | 0.00 | |
Maximum of Months | 454905.91 | 62892.57 | 88772.42 | 15448.40 | 32159.77 | 34110.99 | 7293.30 | 0.00 | 199615.47 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS {Maximum} [W] | INTERIOREQUIPMENT:NATURALGAS {TIMESTAMP} | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 104248.32 | 02-JAN-18:10 | 0.00 | 257985.59 | 02-JAN-09:09 | 0.00 | 288372.64 | 24-JAN-21:19 | 0.00 |
February | 104248.32 | 01-FEB-18:10 | 0.00 | 259652.49 | 06-FEB-09:09 | 0.00 | 288809.98 | 07-FEB-21:00 | 0.00 |
March | 104248.32 | 01-MAR-18:10 | 0.00 | 156101.30 | 12-MAR-09:00 | 0.00 | 297324.00 | 03-MAR-21:19 | 0.00 |
April | 104248.32 | 01-APR-17:10 | 0.00 | 189927.45 | 01-APR-20:30 | 0.00 | 280395.16 | 05-APR-20:00 | 0.00 |
May | 104248.32 | 01-MAY-17:10 | 0.00 | 114516.12 | 15-MAY-02:49 | 0.00 | 249225.20 | 01-MAY-20:19 | 0.00 |
June | 104248.32 | 01-JUN-17:10 | 0.00 | 19032.21 | 22-JUN-19:00 | 0.00 | 245727.48 | 01-JUN-20:30 | 0.00 |
July | 104248.32 | 01-JUL-17:10 | 0.00 | 9686.38 | 15-JUL-08:09 | 0.00 | 243635.40 | 06-JUL-20:40 | 0.00 |
August | 104248.32 | 01-AUG-17:10 | 0.00 | 24893.77 | 30-AUG-14:30 | 0.00 | 242922.91 | 22-AUG-20:49 | 0.00 |
September | 104248.32 | 01-SEP-17:10 | 0.00 | 68622.33 | 30-SEP-05:19 | 0.00 | 244395.15 | 29-SEP-20:49 | 0.00 |
October | 104248.32 | 02-OCT-17:10 | 0.00 | 138000.71 | 31-OCT-08:39 | 0.00 | 247160.95 | 27-OCT-17:49 | 0.00 |
November | 104248.32 | 01-NOV-17:10 | 0.00 | 161147.49 | 28-NOV-12:00 | 0.00 | 261148.92 | 30-NOV-21:00 | 0.00 |
December | 104248.32 | 01-DEC-18:10 | 0.00 | 191097.53 | 31-DEC-23:00 | 0.00 | 284026.06 | 29-DEC-21:30 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 104248.32 | 0.00 | 9686.38 | 0.00 | 242922.91 | 0.00 | |||
Maximum of Months | 104248.32 | 0.00 | 259652.49 | 0.00 | 297324.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 25.17 | 16.67 | 25.17 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 24.83 | 4.67 | 24.83 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 32.67 | 25.11 | 32.67 | 25.11 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 24.50 | 25.05 | 24.50 | 25.05 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 25.08 | 2.33 | 25.08 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.95 | 0.67 | 24.95 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.66 | 0.17 | 24.66 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.58 | 0.83 | 24.58 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 11.33 | 25.28 | 11.33 | 25.28 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 29.67 | 25.05 | 29.67 | 25.05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 18.67 | 25.23 | 18.67 | 25.23 |
Annual Sum or Average | 0.00 | 0.00 | 142.17 | 25.11 | 142.17 | 25.11 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 32.67 | 25.28 | 32.67 | 25.28 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.63 | 0.17 | 24.63 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.67 | 0.17 | 24.67 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.83 | 0.17 | 24.83 |
Annual Sum or Average | 0.00 | 0.00 | 0.50 | 24.71 | 0.50 | 24.71 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.83 | 0.17 | 24.83 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.81 | 0.17 | 21.81 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 21.81 | 1.00 | 21.81 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 21.75 | 1.50 | 21.75 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.74 | 1.33 | 21.74 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 21.84 | 4.33 | 21.84 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 21.84 | 2.17 | 21.84 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.81 | 0.67 | 21.81 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 11.17 | 21.81 | 11.17 | 21.81 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 21.84 | 4.33 | 21.84 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.78 | 0.67 | 21.78 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 21.74 | 1.17 | 21.74 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.71 | 1.33 | 21.71 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 21.78 | 2.33 | 21.78 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.73 | 0.33 | 21.73 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 5.83 | 21.75 | 5.83 | 21.75 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 21.78 | 2.33 | 21.78 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 20.51 | 1.33 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
February | 1.17 | 20.52 | 1.17 | 20.52 | 0.00 | 20.52 | 0.00 | 20.52 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 21.71 | 1.83 | 21.71 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 21.72 | 5.17 | 21.72 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 21.73 | 2.83 | 21.73 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2.50 | 20.51 | 2.50 | 20.51 | 10.00 | 21.32 | 10.00 | 21.48 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.33 | 20.52 | 1.33 | 20.52 | 5.17 | 21.73 | 5.17 | 21.73 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.82 | 0.17 | 21.82 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.78 | 1.33 | 21.78 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.91 | 0.33 | 21.91 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.71 | 0.33 | 21.71 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.77 | 0.67 | 21.77 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.81 | 0.67 | 21.81 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.50 | 21.79 | 3.50 | 21.79 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.91 | 1.33 | 21.91 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.79 | 0.17 | 21.79 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.79 | 1.33 | 21.79 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 21.89 | 0.50 | 21.89 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 21.76 | 0.50 | 21.76 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.77 | 0.67 | 21.77 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.78 | 0.33 | 21.78 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.50 | 21.79 | 3.50 | 21.79 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.89 | 1.33 | 21.89 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.95 | 0.17 | 21.95 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 21.81 | 1.83 | 21.81 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 21.81 | 1.83 | 21.81 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 21.75 | 2.33 | 21.75 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 21.87 | 5.33 | 21.87 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 21.84 | 3.17 | 21.84 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 21.78 | 0.83 | 21.78 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 15.50 | 21.83 | 15.50 | 21.83 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 21.95 | 5.33 | 21.95 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 21.82 | 1.00 | 21.82 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 21.79 | 1.67 | 21.79 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 21.75 | 1.67 | 21.75 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 21.80 | 3.00 | 21.80 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.71 | 0.67 | 21.71 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 8.00 | 21.78 | 8.00 | 21.78 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 21.82 | 3.00 | 21.82 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.84 | 0.33 | 21.84 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.74 | 0.17 | 21.74 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.77 | 0.17 | 21.77 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.70 | 0.17 | 21.70 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 21.82 | 3.17 | 21.82 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 21.89 | 3.00 | 21.89 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 21.88 | 2.83 | 21.88 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 9.83 | 21.86 | 9.83 | 21.86 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 21.89 | 3.17 | 21.89 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 24.85 | 1.67 | 24.85 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 24.74 | 4.00 | 24.74 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 24.74 | 3.67 | 24.74 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.77 | 1.83 | 24.77 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 24.70 | 3.83 | 24.70 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 24.72 | 5.17 | 24.72 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.67 | 1.00 | 24.67 |
Annual Sum or Average | 0.00 | 0.00 | 21.17 | 24.74 | 21.17 | 24.74 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 24.85 | 5.17 | 24.85 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.86 | 2.00 | 24.86 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 24.76 | 6.00 | 24.76 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 24.76 | 5.33 | 24.76 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.86 | 1.83 | 24.86 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 24.75 | 4.33 | 24.75 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 24.74 | 7.17 | 24.74 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.69 | 2.17 | 24.69 |
Annual Sum or Average | 0.00 | 0.00 | 28.83 | 24.76 | 28.83 | 24.76 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 24.86 | 7.17 | 24.86 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 22.50 | 25.12 | 22.50 | 25.12 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 12.17 | 25.11 | 12.17 | 25.11 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 48.00 | 25.20 | 48.00 | 25.20 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 36.50 | 25.13 | 36.50 | 25.13 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 24.95 | 6.33 | 24.95 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 24.89 | 5.17 | 24.89 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.89 | 0.83 | 24.89 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 24.81 | 4.83 | 24.81 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.68 | 0.50 | 24.68 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 21.00 | 25.19 | 21.00 | 25.19 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 48.00 | 25.11 | 48.00 | 25.11 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 31.67 | 25.19 | 31.67 | 25.19 |
Annual Sum or Average | 0.00 | 0.00 | 237.50 | 25.13 | 237.50 | 25.13 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.68 | 0.50 | 24.68 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 48.00 | 25.20 | 48.00 | 25.20 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 725.17 | 23.51 | 0.00 | 23.51 | 0.00 | 23.51 |
February | 672.00 | 23.20 | 0.00 | 23.20 | 0.00 | 23.20 |
March | 744.00 | 22.97 | 0.00 | 22.97 | 0.00 | 22.97 |
April | 720.00 | 22.70 | 0.00 | 22.70 | 0.00 | 22.70 |
May | 744.00 | 22.51 | 0.00 | 22.51 | 0.00 | 22.51 |
June | 703.67 | 22.86 | 0.00 | 22.86 | 0.00 | 22.86 |
July | 443.33 | 23.04 | 20.67 | 23.08 | 0.00 | 23.08 |
August | 254.00 | 23.26 | 260.67 | 23.57 | 0.00 | 23.57 |
September | 105.50 | 23.63 | 286.17 | 23.87 | 0.00 | 23.87 |
October | 240.00 | 23.90 | 243.33 | 23.93 | 0.00 | 23.93 |
November | 335.33 | 23.87 | 20.00 | 23.88 | 0.00 | 23.88 |
December | 655.33 | 23.82 | 0.00 | 23.82 | 0.00 | 23.82 |
Annual Sum or Average | 6342.33 | 23.16 | 830.83 | 23.25 | 0.00 | 23.25 |
Minimum of Months | 105.50 | 22.51 | 0.00 | 22.51 | 0.00 | 22.51 |
Maximum of Months | 744.00 | 23.90 | 286.17 | 23.93 | 0.00 | 23.93 |
Report: ComfortReportSimple55Monthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 729.00 | 21.11 | 346.67 | 21.08 | 344.33 | 21.06 |
February | 646.67 | 21.17 | 311.50 | 21.12 | 311.17 | 21.09 |
March | 692.83 | 21.24 | 112.83 | 21.28 | 90.83 | 21.26 |
April | 652.67 | 21.32 | 39.17 | 21.41 | 14.67 | 21.40 |
May | 658.67 | 21.54 | 31.50 | 21.64 | 0.00 | 21.64 |
June | 447.83 | 22.10 | 161.83 | 22.49 | 0.00 | 22.49 |
July | 230.33 | 22.36 | 362.33 | 23.11 | 0.00 | 23.11 |
August | 177.67 | 22.36 | 453.33 | 23.35 | 0.00 | 23.35 |
September | 428.33 | 21.90 | 215.17 | 22.53 | 0.00 | 22.53 |
October | 500.33 | 21.71 | 172.83 | 22.26 | 0.00 | 22.26 |
November | 675.00 | 21.22 | 108.17 | 21.27 | 88.50 | 21.24 |
December | 712.00 | 21.14 | 310.33 | 21.12 | 303.17 | 21.09 |
Annual Sum or Average | 6551.33 | 21.45 | 2625.67 | 21.76 | 1152.67 | 21.67 |
Minimum of Months | 177.67 | 21.11 | 31.50 | 21.08 | 0.00 | 21.06 |
Maximum of Months | 729.00 | 22.36 | 453.33 | 23.35 | 344.33 | 23.35 |
Report: ComfortReportSimple55Monthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.42 | 39.17 | 21.40 | 39.17 | 21.38 |
February | 672.00 | 21.51 | 34.50 | 21.49 | 34.50 | 21.47 |
March | 744.00 | 22.06 | 0.00 | 22.06 | 0.00 | 22.06 |
April | 684.00 | 22.34 | 7.17 | 22.36 | 0.00 | 22.36 |
May | 619.83 | 22.73 | 45.67 | 22.80 | 1.33 | 22.81 |
June | 229.00 | 23.01 | 314.33 | 23.47 | 9.50 | 23.48 |
July | 67.33 | 23.31 | 518.67 | 23.78 | 26.50 | 23.78 |
August | 42.00 | 23.22 | 539.17 | 23.83 | 7.00 | 23.83 |
September | 309.17 | 22.95 | 243.17 | 23.34 | 7.33 | 23.35 |
October | 507.50 | 22.93 | 110.50 | 23.08 | 0.00 | 23.08 |
November | 715.83 | 22.09 | 0.00 | 22.09 | 0.00 | 22.09 |
December | 744.00 | 21.67 | 2.67 | 21.66 | 2.67 | 21.66 |
Annual Sum or Average | 6078.67 | 22.15 | 1855.00 | 22.52 | 128.00 | 22.51 |
Minimum of Months | 42.00 | 21.42 | 0.00 | 21.40 | 0.00 | 21.38 |
Maximum of Months | 744.00 | 23.31 | 539.17 | 23.83 | 39.17 | 23.83 |
Report: ComfortReportSimple55Monthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.03 | 246.67 | 21.02 | 246.67 | 21.02 |
February | 672.00 | 21.02 | 271.67 | 21.02 | 271.67 | 21.01 |
March | 744.00 | 21.20 | 43.00 | 21.19 | 43.00 | 21.18 |
April | 720.00 | 21.60 | 0.00 | 21.60 | 0.00 | 21.60 |
May | 730.17 | 22.35 | 2.17 | 22.35 | 0.00 | 22.35 |
June | 423.17 | 23.04 | 74.67 | 23.17 | 0.00 | 23.17 |
July | 74.17 | 23.19 | 307.00 | 23.74 | 0.00 | 23.74 |
August | 151.33 | 23.34 | 276.00 | 23.71 | 0.00 | 23.71 |
September | 520.83 | 22.90 | 36.33 | 22.97 | 0.00 | 22.97 |
October | 738.50 | 22.38 | 0.00 | 22.38 | 0.00 | 22.38 |
November | 720.00 | 21.40 | 32.83 | 21.38 | 32.83 | 21.36 |
December | 744.00 | 21.05 | 65.00 | 21.05 | 65.00 | 21.05 |
Annual Sum or Average | 6982.17 | 21.76 | 1355.33 | 21.88 | 659.17 | 21.82 |
Minimum of Months | 74.17 | 21.02 | 0.00 | 21.02 | 0.00 | 21.01 |
Maximum of Months | 744.00 | 23.34 | 307.00 | 23.74 | 271.67 | 23.74 |
Report: ComfortReportSimple55Monthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.00 | 302.83 | 21.00 | 302.83 | 21.00 |
February | 672.00 | 21.00 | 335.50 | 21.00 | 335.50 | 21.00 |
March | 744.00 | 21.09 | 65.33 | 21.08 | 65.33 | 21.08 |
April | 720.00 | 21.43 | 2.33 | 21.43 | 2.33 | 21.43 |
May | 742.17 | 22.17 | 0.00 | 22.17 | 0.00 | 22.17 |
June | 570.83 | 23.00 | 6.67 | 23.01 | 0.00 | 23.01 |
July | 175.00 | 23.24 | 129.00 | 23.49 | 0.00 | 23.49 |
August | 275.67 | 23.33 | 164.33 | 23.53 | 0.00 | 23.53 |
September | 622.00 | 22.83 | 0.00 | 22.83 | 0.00 | 22.83 |
October | 744.00 | 22.20 | 0.00 | 22.20 | 0.00 | 22.20 |
November | 720.00 | 21.25 | 53.00 | 21.24 | 53.00 | 21.22 |
December | 744.00 | 21.01 | 128.83 | 21.01 | 128.83 | 21.01 |
Annual Sum or Average | 7473.67 | 21.76 | 1187.83 | 21.75 | 887.83 | 21.68 |
Minimum of Months | 175.00 | 21.00 | 0.00 | 21.00 | 0.00 | 21.00 |
Maximum of Months | 744.00 | 23.33 | 335.50 | 23.53 | 335.50 | 23.53 |
Report: ComfortReportSimple55Monthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 306.83 | 22.59 | 397.33 | 23.20 | 135.00 | 23.36 |
February | 257.83 | 22.51 | 336.83 | 23.20 | 112.17 | 23.34 |
March | 270.67 | 23.14 | 506.67 | 23.41 | 171.67 | 23.57 |
April | 268.50 | 23.37 | 560.50 | 23.38 | 199.50 | 23.53 |
May | 286.67 | 23.72 | 661.50 | 23.37 | 259.17 | 23.50 |
June | 299.17 | 23.92 | 691.83 | 23.34 | 292.67 | 23.48 |
July | 319.67 | 23.96 | 739.50 | 23.32 | 319.67 | 23.47 |
August | 316.17 | 23.96 | 730.50 | 23.33 | 316.00 | 23.48 |
September | 293.83 | 23.84 | 670.50 | 23.36 | 279.33 | 23.50 |
October | 285.00 | 23.64 | 626.83 | 23.40 | 244.83 | 23.54 |
November | 264.17 | 23.21 | 519.83 | 23.41 | 175.50 | 23.56 |
December | 260.50 | 22.77 | 412.50 | 23.34 | 135.83 | 23.48 |
Annual Sum or Average | 3429.00 | 23.41 | 6854.33 | 23.34 | 2641.33 | 23.49 |
Minimum of Months | 257.83 | 22.51 | 336.83 | 23.20 | 112.17 | 23.34 |
Maximum of Months | 319.67 | 23.96 | 739.50 | 23.41 | 319.67 | 23.57 |
Report: ComfortReportSimple55Monthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 710.00 | 21.54 | 95.17 | 21.53 | 81.17 | 21.48 |
February | 615.83 | 21.69 | 68.67 | 21.73 | 44.17 | 21.68 |
March | 636.33 | 22.08 | 54.17 | 22.23 | 0.00 | 22.23 |
April | 523.50 | 22.14 | 104.00 | 22.40 | 0.00 | 22.40 |
May | 461.50 | 22.57 | 190.50 | 22.88 | 50.33 | 22.93 |
June | 290.00 | 23.43 | 548.67 | 23.55 | 213.67 | 23.60 |
July | 286.33 | 23.85 | 719.83 | 23.73 | 280.00 | 23.77 |
August | 215.50 | 23.88 | 717.17 | 23.83 | 207.67 | 23.85 |
September | 261.17 | 23.07 | 522.00 | 23.53 | 143.33 | 23.57 |
October | 330.00 | 22.99 | 407.83 | 23.45 | 92.17 | 23.49 |
November | 606.00 | 22.05 | 61.83 | 22.21 | 3.33 | 22.22 |
December | 687.33 | 21.74 | 46.17 | 21.82 | 14.50 | 21.81 |
Annual Sum or Average | 5623.50 | 22.30 | 3536.00 | 22.81 | 1130.33 | 22.89 |
Minimum of Months | 215.50 | 21.54 | 46.17 | 21.53 | 0.00 | 21.48 |
Maximum of Months | 710.00 | 23.88 | 719.83 | 23.83 | 280.00 | 23.85 |
Report: ComfortReportSimple55Monthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 22.03 | 6.83 | 22.02 | 6.83 | 22.02 |
February | 672.00 | 22.18 | 0.17 | 22.18 | 0.17 | 22.18 |
March | 703.17 | 22.63 | 0.00 | 22.63 | 0.00 | 22.63 |
April | 564.83 | 22.73 | 56.83 | 22.83 | 0.00 | 22.83 |
May | 415.67 | 22.97 | 173.33 | 23.23 | 45.83 | 23.28 |
June | 257.67 | 23.70 | 492.00 | 23.78 | 188.00 | 23.82 |
July | 244.50 | 23.99 | 690.17 | 23.85 | 244.17 | 23.88 |
August | 176.17 | 24.00 | 698.50 | 23.89 | 176.17 | 23.91 |
September | 217.67 | 23.52 | 468.33 | 23.76 | 128.83 | 23.79 |
October | 318.50 | 23.40 | 322.33 | 23.62 | 71.50 | 23.65 |
November | 640.83 | 22.65 | 23.17 | 22.69 | 3.67 | 22.70 |
December | 743.33 | 22.34 | 0.00 | 22.34 | 0.00 | 22.34 |
Annual Sum or Average | 5698.33 | 22.72 | 2931.67 | 23.10 | 865.17 | 23.18 |
Minimum of Months | 176.17 | 22.03 | 0.00 | 22.02 | 0.00 | 22.02 |
Maximum of Months | 744.00 | 24.00 | 698.50 | 23.89 | 244.17 | 23.91 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.73 | 624.67 | 20.68 | 624.67 | 20.67 |
February | 672.00 | 20.86 | 558.33 | 20.80 | 558.33 | 20.78 |
March | 744.00 | 21.12 | 266.17 | 21.01 | 266.17 | 20.95 |
April | 701.17 | 21.27 | 74.83 | 21.21 | 73.50 | 21.15 |
May | 701.17 | 21.46 | 5.00 | 21.47 | 0.00 | 21.47 |
June | 602.50 | 21.39 | 35.17 | 21.49 | 1.50 | 21.50 |
July | 588.17 | 21.32 | 60.00 | 21.50 | 1.67 | 21.51 |
August | 578.33 | 21.29 | 71.17 | 21.51 | 0.50 | 21.52 |
September | 631.17 | 21.42 | 27.17 | 21.49 | 3.33 | 21.49 |
October | 683.33 | 21.42 | 24.50 | 21.47 | 5.33 | 21.46 |
November | 720.00 | 21.05 | 289.00 | 20.95 | 289.00 | 20.89 |
December | 744.00 | 20.83 | 592.67 | 20.77 | 592.67 | 20.75 |
Annual Sum or Average | 8109.83 | 21.17 | 2628.67 | 21.10 | 2416.67 | 21.03 |
Minimum of Months | 578.33 | 20.73 | 5.00 | 20.68 | 0.00 | 20.67 |
Maximum of Months | 744.00 | 21.46 | 624.67 | 21.51 | 624.67 | 21.52 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.56 | 698.50 | 20.54 | 698.50 | 20.53 |
February | 672.00 | 20.61 | 643.00 | 20.59 | 643.00 | 20.59 |
March | 744.00 | 20.89 | 373.00 | 20.79 | 373.00 | 20.74 |
April | 712.00 | 21.18 | 112.83 | 21.10 | 112.83 | 21.04 |
May | 717.00 | 21.46 | 3.83 | 21.47 | 0.00 | 21.47 |
June | 618.33 | 21.43 | 26.83 | 21.50 | 1.17 | 21.51 |
July | 601.83 | 21.36 | 47.50 | 21.50 | 2.00 | 21.50 |
August | 611.33 | 21.38 | 43.33 | 21.51 | 0.83 | 21.51 |
September | 667.17 | 21.46 | 11.33 | 21.49 | 2.50 | 21.49 |
October | 722.83 | 21.34 | 35.67 | 21.32 | 35.00 | 21.30 |
November | 720.00 | 20.82 | 381.00 | 20.73 | 381.00 | 20.68 |
December | 744.00 | 20.60 | 705.33 | 20.58 | 705.33 | 20.58 |
Annual Sum or Average | 8274.50 | 21.08 | 3082.17 | 20.97 | 2955.17 | 20.89 |
Minimum of Months | 601.83 | 20.56 | 3.83 | 20.54 | 0.00 | 20.53 |
Maximum of Months | 744.00 | 21.46 | 705.33 | 21.51 | 705.33 | 21.51 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.76 | 544.83 | 20.72 | 544.83 | 20.70 |
February | 672.00 | 20.76 | 581.33 | 20.73 | 581.33 | 20.72 |
March | 744.00 | 20.98 | 279.50 | 20.93 | 279.50 | 20.90 |
April | 720.00 | 21.18 | 24.00 | 21.17 | 24.00 | 21.16 |
May | 744.00 | 21.38 | 0.00 | 21.38 | 0.00 | 21.38 |
June | 720.00 | 21.51 | 7.83 | 21.52 | 7.83 | 21.53 |
July | 744.00 | 21.61 | 5.83 | 21.62 | 5.83 | 21.63 |
August | 744.00 | 21.57 | 2.00 | 21.57 | 2.00 | 21.57 |
September | 720.00 | 21.39 | 4.50 | 21.39 | 4.50 | 21.40 |
October | 744.00 | 21.22 | 4.83 | 21.22 | 4.83 | 21.22 |
November | 720.00 | 20.99 | 204.00 | 20.93 | 204.00 | 20.89 |
December | 744.00 | 20.81 | 552.33 | 20.77 | 552.33 | 20.76 |
Annual Sum or Average | 8760.00 | 21.18 | 2211.00 | 21.09 | 2211.00 | 21.03 |
Minimum of Months | 672.00 | 20.76 | 0.00 | 20.72 | 0.00 | 20.70 |
Maximum of Months | 744.00 | 21.61 | 581.33 | 21.62 | 581.33 | 21.63 |
Report: ComfortReportSimple55Monthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.72 | 622.00 | 20.68 | 622.00 | 20.67 |
February | 672.00 | 20.87 | 541.50 | 20.82 | 541.50 | 20.79 |
March | 744.00 | 21.17 | 253.67 | 21.06 | 253.67 | 20.99 |
April | 700.83 | 21.34 | 79.50 | 21.26 | 79.50 | 21.21 |
May | 708.50 | 21.52 | 1.50 | 21.53 | 0.00 | 21.53 |
June | 588.33 | 21.35 | 6.83 | 21.38 | 2.00 | 21.38 |
July | 570.33 | 21.26 | 25.67 | 21.35 | 1.50 | 21.35 |
August | 560.33 | 21.23 | 54.67 | 21.42 | 0.17 | 21.42 |
September | 603.50 | 21.36 | 14.50 | 21.39 | 3.67 | 21.40 |
October | 677.50 | 21.45 | 6.50 | 21.45 | 5.17 | 21.45 |
November | 720.00 | 21.09 | 271.33 | 20.99 | 271.33 | 20.93 |
December | 744.00 | 20.83 | 577.83 | 20.77 | 577.83 | 20.75 |
Annual Sum or Average | 8033.33 | 21.17 | 2455.50 | 21.09 | 2358.33 | 21.02 |
Minimum of Months | 560.33 | 20.72 | 1.50 | 20.68 | 0.00 | 20.67 |
Maximum of Months | 744.00 | 21.52 | 622.00 | 21.53 | 622.00 | 21.53 |
Report: ComfortReportSimple55Monthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.56 | 689.17 | 20.53 | 689.17 | 20.53 |
February | 672.00 | 20.61 | 640.83 | 20.60 | 640.83 | 20.59 |
March | 744.00 | 20.93 | 355.67 | 20.85 | 355.67 | 20.81 |
April | 715.67 | 21.29 | 104.83 | 21.20 | 104.83 | 21.14 |
May | 717.83 | 21.53 | 1.50 | 21.54 | 0.00 | 21.54 |
June | 608.83 | 21.42 | 4.50 | 21.43 | 1.83 | 21.44 |
July | 572.83 | 21.27 | 11.33 | 21.31 | 1.50 | 21.31 |
August | 569.83 | 21.26 | 9.67 | 21.30 | 0.50 | 21.30 |
September | 667.83 | 21.52 | 5.00 | 21.52 | 3.00 | 21.52 |
October | 739.00 | 21.45 | 36.83 | 21.43 | 36.83 | 21.41 |
November | 720.00 | 20.86 | 348.17 | 20.76 | 348.17 | 20.71 |
December | 744.00 | 20.59 | 689.50 | 20.57 | 689.50 | 20.57 |
Annual Sum or Average | 8215.83 | 21.09 | 2897.00 | 20.97 | 2871.83 | 20.89 |
Minimum of Months | 569.83 | 20.56 | 1.50 | 20.53 | 0.00 | 20.53 |
Maximum of Months | 744.00 | 21.53 | 689.50 | 21.54 | 689.50 | 21.54 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.02 | 221.33 | 21.01 | 221.33 | 21.01 |
February | 672.00 | 21.02 | 213.67 | 21.02 | 213.67 | 21.01 |
March | 744.00 | 21.22 | 4.00 | 21.22 | 4.00 | 21.22 |
April | 720.00 | 21.71 | 0.00 | 21.71 | 0.00 | 21.71 |
May | 734.83 | 22.44 | 1.00 | 22.44 | 1.00 | 22.44 |
June | 481.33 | 23.21 | 49.00 | 23.27 | 14.17 | 23.27 |
July | 103.00 | 23.50 | 300.67 | 23.76 | 55.33 | 23.74 |
August | 92.83 | 23.60 | 351.00 | 23.85 | 23.83 | 23.84 |
September | 493.00 | 22.96 | 72.67 | 23.08 | 10.17 | 23.08 |
October | 743.00 | 22.65 | 0.00 | 22.65 | 0.00 | 22.65 |
November | 720.00 | 21.37 | 23.17 | 21.36 | 23.17 | 21.34 |
December | 744.00 | 21.03 | 68.83 | 21.03 | 68.83 | 21.03 |
Annual Sum or Average | 6992.00 | 21.83 | 1305.33 | 21.97 | 635.50 | 21.93 |
Minimum of Months | 92.83 | 21.02 | 0.00 | 21.01 | 0.00 | 21.01 |
Maximum of Months | 744.00 | 23.60 | 351.00 | 23.85 | 221.33 | 23.84 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.65 | 681.17 | 20.62 | 681.17 | 20.61 |
February | 672.00 | 20.77 | 597.50 | 20.72 | 597.50 | 20.71 |
March | 743.67 | 21.05 | 352.67 | 20.92 | 352.67 | 20.86 |
April | 697.17 | 21.21 | 171.67 | 21.11 | 167.33 | 21.04 |
May | 687.33 | 21.40 | 12.83 | 21.43 | 2.83 | 21.43 |
June | 592.83 | 21.35 | 65.67 | 21.53 | 11.00 | 21.54 |
July | 581.67 | 21.30 | 91.00 | 21.57 | 5.50 | 21.57 |
August | 566.83 | 21.26 | 98.67 | 21.56 | 1.83 | 21.57 |
September | 621.33 | 21.37 | 43.67 | 21.48 | 8.00 | 21.48 |
October | 678.83 | 21.36 | 93.00 | 21.39 | 67.33 | 21.35 |
November | 720.00 | 20.95 | 400.50 | 20.84 | 400.50 | 20.80 |
December | 744.00 | 20.74 | 666.67 | 20.70 | 666.67 | 20.69 |
Annual Sum or Average | 8049.67 | 21.10 | 3275.00 | 21.05 | 2962.33 | 20.97 |
Minimum of Months | 566.83 | 20.65 | 12.83 | 20.62 | 1.83 | 20.61 |
Maximum of Months | 744.00 | 21.40 | 681.17 | 21.57 | 681.17 | 21.57 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.51 | 719.67 | 20.50 | 719.67 | 20.50 |
February | 672.00 | 20.55 | 655.83 | 20.54 | 655.83 | 20.54 |
March | 744.00 | 20.81 | 474.33 | 20.72 | 474.33 | 20.68 |
April | 708.67 | 21.12 | 215.50 | 21.02 | 215.33 | 20.95 |
May | 703.17 | 21.41 | 10.83 | 21.43 | 3.83 | 21.43 |
June | 605.50 | 21.38 | 50.00 | 21.51 | 10.00 | 21.52 |
July | 589.50 | 21.32 | 73.00 | 21.53 | 6.33 | 21.54 |
August | 595.67 | 21.33 | 65.17 | 21.52 | 2.00 | 21.53 |
September | 657.83 | 21.41 | 19.83 | 21.45 | 7.33 | 21.45 |
October | 721.00 | 21.26 | 128.50 | 21.21 | 125.83 | 21.17 |
November | 720.00 | 20.73 | 480.67 | 20.65 | 480.67 | 20.62 |
December | 744.00 | 20.53 | 736.67 | 20.53 | 736.67 | 20.53 |
Annual Sum or Average | 8205.33 | 21.01 | 3630.00 | 20.92 | 3437.83 | 20.84 |
Minimum of Months | 589.50 | 20.51 | 10.83 | 20.50 | 2.00 | 20.50 |
Maximum of Months | 744.00 | 21.41 | 736.67 | 21.53 | 736.67 | 21.54 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 739.17 | 21.01 | 477.17 | 20.90 | 477.17 | 20.85 |
February | 671.83 | 21.22 | 394.17 | 21.07 | 394.17 | 21.01 |
March | 721.33 | 21.23 | 201.00 | 21.13 | 201.00 | 21.07 |
April | 691.50 | 21.31 | 67.83 | 21.27 | 62.50 | 21.22 |
May | 707.00 | 21.46 | 0.00 | 21.46 | 0.00 | 21.46 |
June | 626.00 | 21.42 | 14.17 | 21.44 | 12.83 | 21.46 |
July | 610.67 | 21.37 | 26.17 | 21.44 | 8.83 | 21.46 |
August | 596.67 | 21.33 | 80.00 | 21.57 | 2.00 | 21.57 |
September | 610.33 | 21.36 | 53.50 | 21.50 | 6.17 | 21.51 |
October | 633.17 | 21.33 | 52.67 | 21.49 | 1.17 | 21.49 |
November | 700.67 | 21.29 | 164.50 | 21.21 | 163.67 | 21.15 |
December | 736.83 | 21.12 | 419.33 | 21.00 | 419.33 | 20.94 |
Annual Sum or Average | 8045.17 | 21.28 | 1950.50 | 21.24 | 1748.83 | 21.17 |
Minimum of Months | 596.67 | 21.01 | 0.00 | 20.90 | 0.00 | 20.85 |
Maximum of Months | 739.17 | 21.46 | 477.17 | 21.57 | 477.17 | 21.57 |
Report: ComfortReportSimple55Monthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 582.50 | 22.97 | 12.50 | 22.99 | 0.00 | 22.99 |
February | 554.33 | 23.04 | 0.00 | 23.04 | 0.00 | 23.04 |
March | 355.17 | 23.13 | 79.67 | 23.30 | 0.00 | 23.30 |
April | 152.50 | 23.13 | 283.50 | 23.68 | 0.00 | 23.68 |
May | 65.83 | 23.80 | 601.83 | 23.93 | 50.00 | 23.93 |
June | 182.00 | 24.00 | 708.67 | 23.97 | 182.00 | 23.98 |
July | 227.33 | 24.00 | 744.00 | 23.99 | 227.33 | 23.99 |
August | 174.67 | 24.00 | 743.17 | 23.98 | 174.67 | 23.98 |
September | 129.50 | 24.00 | 670.50 | 23.95 | 129.50 | 23.96 |
October | 195.33 | 23.61 | 426.00 | 23.81 | 89.33 | 23.83 |
November | 342.33 | 23.07 | 108.33 | 23.30 | 4.83 | 23.30 |
December | 525.67 | 23.09 | 7.00 | 23.11 | 0.00 | 23.11 |
Annual Sum or Average | 3487.17 | 23.29 | 4385.17 | 23.67 | 857.67 | 23.70 |
Minimum of Months | 65.83 | 22.97 | 0.00 | 22.99 | 0.00 | 22.99 |
Maximum of Months | 582.50 | 24.00 | 744.00 | 23.99 | 227.33 | 23.99 |
Report: ComfortReportSimple55Monthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 432.17 | 23.06 | 53.00 | 23.17 | 0.00 | 23.17 |
February | 426.67 | 23.15 | 13.17 | 23.17 | 0.00 | 23.17 |
March | 186.83 | 23.11 | 222.00 | 23.61 | 0.00 | 23.61 |
April | 60.67 | 23.21 | 419.67 | 23.88 | 0.00 | 23.88 |
May | 41.17 | 24.00 | 685.50 | 23.96 | 41.17 | 23.97 |
June | 165.00 | 24.00 | 715.83 | 23.99 | 165.00 | 23.99 |
July | 211.50 | 24.00 | 744.00 | 23.99 | 211.50 | 23.99 |
August | 160.00 | 24.00 | 744.00 | 23.99 | 160.00 | 23.99 |
September | 116.50 | 24.00 | 701.67 | 23.97 | 116.50 | 23.97 |
October | 105.33 | 23.77 | 484.00 | 23.91 | 71.00 | 23.92 |
November | 196.50 | 23.14 | 227.00 | 23.61 | 2.83 | 23.61 |
December | 347.67 | 23.10 | 42.17 | 23.20 | 0.00 | 23.20 |
Annual Sum or Average | 2450.00 | 23.39 | 5052.00 | 23.79 | 768.00 | 23.81 |
Minimum of Months | 41.17 | 23.06 | 13.17 | 23.17 | 0.00 | 23.17 |
Maximum of Months | 432.17 | 24.00 | 744.00 | 23.99 | 211.50 | 23.99 |
Report: ComfortReportSimple55Monthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 535.17 | 23.74 | 598.67 | 23.87 | 451.67 | 23.92 |
February | 493.67 | 23.70 | 531.33 | 23.86 | 404.83 | 23.91 |
March | 529.50 | 24.07 | 657.33 | 24.05 | 503.83 | 24.08 |
April | 512.67 | 24.10 | 677.33 | 24.01 | 511.67 | 24.04 |
May | 554.33 | 24.01 | 743.83 | 23.94 | 554.33 | 23.96 |
June | 562.83 | 24.00 | 720.00 | 23.97 | 562.83 | 23.98 |
July | 602.67 | 23.99 | 744.00 | 23.98 | 602.67 | 23.98 |
August | 597.67 | 24.01 | 744.00 | 23.99 | 597.67 | 24.00 |
September | 547.83 | 24.00 | 719.83 | 23.95 | 547.83 | 23.96 |
October | 542.17 | 24.06 | 716.83 | 23.99 | 542.00 | 24.01 |
November | 513.67 | 24.05 | 648.83 | 24.02 | 491.33 | 24.05 |
December | 528.00 | 23.89 | 609.67 | 23.96 | 470.83 | 24.00 |
Annual Sum or Average | 6520.17 | 23.97 | 8111.67 | 23.97 | 6241.50 | 23.99 |
Minimum of Months | 493.67 | 23.70 | 531.33 | 23.86 | 404.83 | 23.91 |
Maximum of Months | 602.67 | 24.10 | 744.00 | 24.05 | 602.67 | 24.08 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.02 | 268.83 | 21.01 | 268.83 | 21.01 |
February | 672.00 | 21.03 | 275.33 | 21.02 | 275.33 | 21.02 |
March | 744.00 | 21.22 | 20.67 | 21.22 | 20.67 | 21.21 |
April | 716.33 | 21.66 | 0.00 | 21.66 | 0.00 | 21.66 |
May | 692.67 | 22.37 | 29.00 | 22.43 | 0.00 | 22.43 |
June | 261.17 | 23.03 | 225.50 | 23.41 | 0.00 | 23.41 |
July | 14.83 | 23.03 | 589.67 | 23.85 | 0.00 | 23.85 |
August | 61.67 | 23.19 | 495.33 | 23.82 | 0.00 | 23.82 |
September | 436.00 | 22.74 | 136.67 | 23.01 | 0.00 | 23.01 |
October | 694.83 | 22.27 | 12.67 | 22.30 | 0.00 | 22.30 |
November | 720.00 | 21.24 | 34.33 | 21.23 | 34.33 | 21.22 |
December | 744.00 | 21.04 | 80.50 | 21.03 | 80.50 | 21.03 |
Annual Sum or Average | 6501.50 | 21.64 | 2168.50 | 21.97 | 679.67 | 21.90 |
Minimum of Months | 14.83 | 21.02 | 0.00 | 21.01 | 0.00 | 21.01 |
Maximum of Months | 744.00 | 23.19 | 589.67 | 23.85 | 275.33 | 23.85 |
Report: OccupantComfortDataSummaryMonthly
For: BASEMENT PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.52642 | 27.54466 | 0.13716 | 5.57661 |
February | 672.00000 | 23.20375 | 24.03746 | 0.02914 | 5.20003 |
March | 744.00000 | 22.96987 | 32.89101 | 0.02643 | 5.24541 |
April | 720.00000 | 22.70316 | 39.59675 | 0.00254 | 5.22123 |
May | 744.00000 | 22.51496 | 48.05183 | -1.0494 | 28.52350 |
June | 720.00000 | 22.87297 | 57.53287 | -0.8537 | 20.72368 |
July | 744.00000 | 23.26157 | 60.05889 | -0.6909 | 15.29094 |
August | 744.00000 | 23.60807 | 56.12961 | -0.5853 | 12.40063 |
September | 720.00000 | 23.84319 | 51.14197 | -0.5269 | 11.01683 |
October | 744.00000 | 23.91667 | 42.67790 | 0.35755 | 7.89438 |
November | 720.00000 | 23.92556 | 32.89853 | 0.28863 | 6.83731 |
December | 744.00000 | 23.83951 | 26.92743 | 0.21860 | 6.08255 |
Annual Sum or Average | 8760.00000 | 23.35014 | 41.72842 | -0.2220 | 10.87947 |
Minimum of Months | 672.00000 | 22.51496 | 24.03746 | -1.0494 | 5.20003 |
Maximum of Months | 744.00000 | 23.92556 | 60.05889 | 0.35755 | 28.52350 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_1_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.16809 | 29.22259 | -0.4868 | 10.86773 |
February | 672.00000 | 21.27123 | 24.56398 | -0.4559 | 10.59896 |
March | 744.00000 | 21.41376 | 34.04069 | -0.3099 | 8.41757 |
April | 720.00000 | 21.53707 | 40.55744 | -0.2089 | 7.55638 |
May | 744.00000 | 21.75574 | 48.76364 | -1.1427 | 34.33590 |
June | 720.00000 | 22.56702 | 57.71632 | -0.7495 | 18.60145 |
July | 744.00000 | 23.06526 | 60.48992 | -0.5292 | 12.15441 |
August | 744.00000 | 23.29453 | 56.39561 | -0.4469 | 10.92899 |
September | 720.00000 | 22.58320 | 53.86772 | -0.7549 | 20.67813 |
October | 744.00000 | 22.36481 | 45.21495 | 0.10804 | 7.97600 |
November | 720.00000 | 21.38044 | 36.38306 | -0.3080 | 8.38623 |
December | 744.00000 | 21.25836 | 29.09330 | -0.4328 | 10.08893 |
Annual Sum or Average | 8760.00000 | 21.97689 | 43.13252 | -0.4763 | 13.40080 |
Minimum of Months | 672.00000 | 21.16809 | 24.56398 | -1.1427 | 7.55638 |
Maximum of Months | 744.00000 | 23.29453 | 60.48992 | 0.10804 | 34.33590 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_2_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.41957 | 30.97969 | -0.3491 | 7.96178 |
February | 672.00000 | 21.51344 | 26.41385 | -0.3483 | 7.90890 |
March | 744.00000 | 22.06276 | 34.98893 | -0.1508 | 6.02586 |
April | 720.00000 | 22.41386 | 40.81004 | -0.0198 | 5.78487 |
May | 744.00000 | 22.88858 | 47.90359 | -0.8473 | 20.96806 |
June | 720.00000 | 23.45066 | 56.78073 | -0.5691 | 12.30835 |
July | 744.00000 | 23.66092 | 60.02799 | -0.4610 | 9.69698 |
August | 744.00000 | 23.74406 | 56.64711 | -0.4467 | 9.41327 |
September | 720.00000 | 23.38613 | 53.46676 | -0.6150 | 13.76258 |
October | 744.00000 | 23.14161 | 45.56460 | 0.21003 | 6.57651 |
November | 720.00000 | 22.10194 | 37.12319 | -0.1281 | 6.04565 |
December | 744.00000 | 21.66720 | 30.66352 | -0.2831 | 7.01614 |
Annual Sum or Average | 8760.00000 | 22.62762 | 43.54807 | -0.3339 | 9.46825 |
Minimum of Months | 672.00000 | 21.41957 | 26.41385 | -0.8473 | 5.78487 |
Maximum of Months | 744.00000 | 23.74406 | 60.02799 | 0.21003 | 20.96806 |
Report: OccupantComfortDataSummaryMonthly
For: LAUNDRY_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.78900 | 24.90881 | 0.51416 | 13.70544 |
February | 672.00000 | 22.80602 | 20.76621 | 0.49456 | 13.12854 |
March | 744.00000 | 22.98334 | 29.18840 | 0.62613 | 16.32693 |
April | 720.00000 | 22.96893 | 35.41960 | 0.68970 | 17.97000 |
May | 744.00000 | 23.01061 | 43.14890 | 0.06208 | 10.31095 |
June | 720.00000 | 23.01533 | 53.55174 | 0.17506 | 10.78722 |
July | 744.00000 | 23.02851 | 57.33214 | 0.22377 | 10.85812 |
August | 744.00000 | 23.02868 | 54.38790 | 0.21418 | 10.92513 |
September | 720.00000 | 23.01492 | 50.08172 | 0.13803 | 10.60319 |
October | 744.00000 | 23.02139 | 41.55247 | 0.76921 | 20.20467 |
November | 720.00000 | 23.00751 | 31.23988 | 0.64640 | 16.75170 |
December | 744.00000 | 22.88003 | 24.76952 | 0.54792 | 14.22548 |
Annual Sum or Average | 8760.00000 | 22.96372 | 38.97034 | 0.42467 | 13.81978 |
Minimum of Months | 672.00000 | 22.78900 | 20.76621 | 0.06208 | 10.31095 |
Maximum of Months | 744.00000 | 23.02868 | 57.33214 | 0.76921 | 20.20467 |
Report: OccupantComfortDataSummaryMonthly
For: CAFE_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.63851 | 34.09724 | -0.2697 | 7.74305 |
February | 672.00000 | 21.85952 | 29.43355 | -0.2135 | 7.41806 |
March | 744.00000 | 22.32043 | 38.09600 | -0.0125 | 6.47244 |
April | 720.00000 | 22.51982 | 44.07100 | 0.09652 | 6.78934 |
May | 744.00000 | 22.90455 | 51.43180 | -0.6915 | 16.53761 |
June | 720.00000 | 23.40098 | 60.38212 | -0.4017 | 9.18149 |
July | 744.00000 | 23.64217 | 63.31697 | -0.2592 | 6.87605 |
August | 744.00000 | 23.77485 | 59.69076 | -0.2025 | 6.46945 |
September | 720.00000 | 23.45339 | 56.58989 | -0.3866 | 10.00732 |
October | 744.00000 | 23.40911 | 48.22831 | 0.42354 | 10.24857 |
November | 720.00000 | 22.29709 | 40.15012 | -0.0072 | 6.59158 |
December | 744.00000 | 21.89320 | 33.69205 | -0.1835 | 7.09248 |
Annual Sum or Average | 8760.00000 | 22.76513 | 46.69885 | -0.1754 | 8.46418 |
Minimum of Months | 672.00000 | 21.63851 | 29.43355 | -0.6915 | 6.46945 |
Maximum of Months | 744.00000 | 23.77485 | 63.31697 | 0.42354 | 16.53761 |
Report: OccupantComfortDataSummaryMonthly
For: LOBBY_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.03418 | 33.42354 | -0.1765 | 6.29542 |
February | 672.00000 | 22.17590 | 28.95880 | -0.1620 | 6.12359 |
March | 744.00000 | 22.70247 | 37.30146 | 0.03217 | 5.65074 |
April | 720.00000 | 22.94548 | 43.03093 | 0.14152 | 6.18180 |
May | 744.00000 | 23.31670 | 50.06864 | -0.6539 | 14.75390 |
June | 720.00000 | 23.62830 | 59.03482 | -0.4493 | 9.63897 |
July | 744.00000 | 23.75044 | 62.24407 | -0.3654 | 7.97907 |
August | 744.00000 | 23.83341 | 58.91263 | -0.3488 | 7.68052 |
September | 720.00000 | 23.67983 | 55.51932 | -0.4538 | 9.84079 |
October | 744.00000 | 23.60470 | 47.60305 | 0.36747 | 8.35549 |
November | 720.00000 | 22.77733 | 39.22079 | 0.06537 | 5.89642 |
December | 744.00000 | 22.34546 | 33.01415 | -0.0939 | 5.78168 |
Annual Sum or Average | 8760.00000 | 23.07140 | 45.79347 | -0.1749 | 7.86192 |
Minimum of Months | 672.00000 | 22.03418 | 28.95880 | -0.6539 | 5.65074 |
Maximum of Months | 744.00000 | 23.83341 | 62.24407 | 0.36747 | 14.75390 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.73291 | 32.82515 | -0.6607 | 14.82213 |
February | 672.00000 | 20.85908 | 27.50920 | -0.6419 | 14.40345 |
March | 744.00000 | 21.12493 | 37.85444 | -0.4477 | 10.07103 |
April | 720.00000 | 21.32338 | 45.01862 | -0.3058 | 8.09797 |
May | 744.00000 | 21.56698 | 51.95537 | -1.2567 | 39.29638 |
June | 720.00000 | 21.69974 | 56.26797 | -1.0871 | 31.59623 |
July | 744.00000 | 21.73122 | 56.45298 | -1.0370 | 29.50469 |
August | 744.00000 | 21.73437 | 53.97734 | -1.0289 | 29.31820 |
September | 720.00000 | 21.65351 | 55.05151 | -1.1487 | 34.45770 |
October | 744.00000 | 21.57279 | 48.81738 | -0.1560 | 6.76896 |
November | 720.00000 | 21.04770 | 41.27688 | -0.4695 | 10.43943 |
December | 744.00000 | 20.83000 | 32.88155 | -0.6175 | 13.60962 |
Annual Sum or Average | 8760.00000 | 21.32568 | 45.08602 | -0.7388 | 20.23605 |
Minimum of Months | 672.00000 | 20.73291 | 27.50920 | -1.2567 | 6.76896 |
Maximum of Months | 744.00000 | 21.73437 | 56.45298 | -0.1560 | 39.29638 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.55849 | 33.09369 | -0.7257 | 16.68736 |
February | 672.00000 | 20.60662 | 27.84801 | -0.7357 | 16.95744 |
March | 744.00000 | 20.89415 | 38.24842 | -0.5291 | 11.49891 |
April | 720.00000 | 21.20804 | 45.39222 | -0.3508 | 8.50452 |
May | 744.00000 | 21.53163 | 52.10638 | -1.2808 | 40.30693 |
June | 720.00000 | 21.69298 | 56.44663 | -1.0976 | 31.96011 |
July | 744.00000 | 21.72797 | 56.79679 | -1.0475 | 29.84793 |
August | 744.00000 | 21.72133 | 54.64047 | -1.0585 | 30.34977 |
September | 720.00000 | 21.59557 | 55.94570 | -1.2007 | 36.54346 |
October | 744.00000 | 21.39891 | 50.37497 | -0.2329 | 7.11171 |
November | 720.00000 | 20.82355 | 41.76918 | -0.5495 | 12.02526 |
December | 744.00000 | 20.59668 | 33.26039 | -0.6995 | 15.74040 |
Annual Sum or Average | 8760.00000 | 21.19971 | 45.59044 | -0.7928 | 21.48943 |
Minimum of Months | 672.00000 | 20.55849 | 27.84801 | -1.2808 | 7.11171 |
Maximum of Months | 744.00000 | 21.72797 | 56.79679 | -0.2329 | 40.30693 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT19_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_4_MULT19_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.76448 | 31.57265 | -0.6162 | 13.41867 |
February | 672.00000 | 20.75507 | 26.49253 | -0.6494 | 14.23509 |
March | 744.00000 | 20.97692 | 36.92807 | -0.4992 | 10.44205 |
April | 720.00000 | 21.17916 | 44.13613 | -0.3723 | 8.17051 |
May | 744.00000 | 21.38177 | 50.72387 | -1.4046 | 45.94708 |
June | 720.00000 | 21.51451 | 57.49845 | -1.2762 | 39.52794 |
July | 744.00000 | 21.61236 | 58.06445 | -1.2218 | 37.04335 |
August | 744.00000 | 21.56956 | 56.01823 | -1.2574 | 38.69393 |
September | 720.00000 | 21.39268 | 55.69016 | -1.3594 | 43.62136 |
October | 744.00000 | 21.22269 | 49.84086 | -0.3137 | 7.38183 |
November | 720.00000 | 20.98761 | 40.22375 | -0.4763 | 10.05872 |
December | 744.00000 | 20.81314 | 31.76133 | -0.5959 | 12.69290 |
Annual Sum or Average | 8760.00000 | 21.18337 | 45.01490 | -0.8380 | 23.49083 |
Minimum of Months | 672.00000 | 20.75507 | 26.49253 | -1.4046 | 7.38183 |
Maximum of Months | 744.00000 | 21.61236 | 58.06445 | -0.3137 | 45.94708 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_5_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.72280 | 32.81954 | -0.6604 | 14.75637 |
February | 672.00000 | 20.86826 | 27.47590 | -0.6355 | 14.12485 |
March | 744.00000 | 21.17387 | 37.80140 | -0.4413 | 9.96094 |
April | 720.00000 | 21.38955 | 44.88082 | -0.2887 | 8.00805 |
May | 744.00000 | 21.60776 | 51.81624 | -1.2379 | 38.48481 |
June | 720.00000 | 21.71455 | 56.58341 | -1.0907 | 31.72335 |
July | 744.00000 | 21.74205 | 56.51572 | -1.0354 | 29.44515 |
August | 744.00000 | 21.74859 | 54.06159 | -1.0246 | 29.14042 |
September | 720.00000 | 21.67508 | 55.07442 | -1.1381 | 34.00714 |
October | 744.00000 | 21.61543 | 48.86357 | -0.1486 | 6.73753 |
November | 720.00000 | 21.08775 | 41.16080 | -0.4516 | 10.15682 |
December | 744.00000 | 20.82730 | 32.87471 | -0.6136 | 13.46942 |
Annual Sum or Average | 8760.00000 | 21.35039 | 45.08944 | -0.7312 | 20.03888 |
Minimum of Months | 672.00000 | 20.72280 | 27.47590 | -1.2379 | 6.73753 |
Maximum of Months | 744.00000 | 21.74859 | 56.58341 | -0.1486 | 38.48481 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_6_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.55538 | 33.08325 | -0.7245 | 16.67019 |
February | 672.00000 | 20.60755 | 27.81647 | -0.7311 | 16.80222 |
March | 744.00000 | 20.93384 | 38.19153 | -0.5248 | 11.26616 |
April | 720.00000 | 21.29991 | 45.10276 | -0.3290 | 8.29934 |
May | 744.00000 | 21.59665 | 51.88392 | -1.2554 | 39.18753 |
June | 720.00000 | 21.71294 | 56.78174 | -1.0997 | 32.02513 |
July | 744.00000 | 21.74104 | 56.88304 | -1.0451 | 29.76136 |
August | 744.00000 | 21.74478 | 54.70815 | -1.0513 | 30.06720 |
September | 720.00000 | 21.64660 | 55.68226 | -1.1827 | 35.74203 |
October | 744.00000 | 21.46162 | 50.03086 | -0.2235 | 7.00696 |
November | 720.00000 | 20.86080 | 41.65415 | -0.5312 | 11.61936 |
December | 744.00000 | 20.59194 | 33.25034 | -0.6959 | 15.68332 |
Annual Sum or Average | 8760.00000 | 21.23288 | 45.51905 | -0.7832 | 21.20538 |
Minimum of Months | 672.00000 | 20.55538 | 27.81647 | -1.2554 | 7.00696 |
Maximum of Months | 744.00000 | 21.74478 | 56.88304 | -0.2235 | 39.18753 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.65061 | 33.28086 | -0.7215 | 16.65355 |
February | 672.00000 | 20.77065 | 27.88095 | -0.7042 | 16.25184 |
March | 744.00000 | 21.04651 | 38.33463 | -0.4933 | 11.18165 |
April | 720.00000 | 21.27215 | 45.64543 | -0.3353 | 8.78009 |
May | 744.00000 | 21.54712 | 52.94370 | -1.2707 | 40.22935 |
June | 720.00000 | 21.69153 | 57.47311 | -1.0843 | 31.69367 |
July | 744.00000 | 21.72894 | 57.38726 | -1.0275 | 29.32083 |
August | 744.00000 | 21.73076 | 54.84623 | -1.0216 | 29.29567 |
September | 720.00000 | 21.63434 | 56.36846 | -1.1603 | 35.23243 |
October | 744.00000 | 21.52695 | 50.01927 | -0.1831 | 7.20324 |
November | 720.00000 | 20.94660 | 41.89114 | -0.5258 | 11.75968 |
December | 744.00000 | 20.73948 | 33.33378 | -0.6778 | 15.30553 |
Annual Sum or Average | 8760.00000 | 21.27671 | 45.88090 | -0.7676 | 21.10661 |
Minimum of Months | 672.00000 | 20.65061 | 27.88095 | -1.2707 | 7.20324 |
Maximum of Months | 744.00000 | 21.73076 | 57.47311 | -0.1831 | 40.22935 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.51144 | 33.50900 | -0.7812 | 18.50618 |
February | 672.00000 | 20.55052 | 28.19964 | -0.7936 | 18.87223 |
March | 744.00000 | 20.81209 | 38.75480 | -0.5781 | 12.79011 |
April | 720.00000 | 21.15409 | 46.02771 | -0.3827 | 9.24834 |
May | 744.00000 | 21.51609 | 53.08411 | -1.2947 | 41.21500 |
June | 720.00000 | 21.68602 | 57.62739 | -1.0948 | 32.04004 |
July | 744.00000 | 21.72616 | 57.69489 | -1.0383 | 29.65599 |
August | 744.00000 | 21.71732 | 55.50344 | -1.0526 | 30.32952 |
September | 720.00000 | 21.57503 | 57.30209 | -1.2156 | 37.43774 |
October | 744.00000 | 21.32662 | 51.73282 | -0.2700 | 7.74755 |
November | 720.00000 | 20.72682 | 42.39669 | -0.6079 | 13.52539 |
December | 744.00000 | 20.52975 | 33.69220 | -0.7571 | 17.56721 |
Annual Sum or Average | 8760.00000 | 21.15616 | 46.39265 | -0.8224 | 22.43322 |
Minimum of Months | 672.00000 | 20.51144 | 28.19964 | -1.2947 | 7.74755 |
Maximum of Months | 744.00000 | 21.72616 | 57.69489 | -0.2700 | 41.21500 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT9_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.02399 | 33.88599 | -0.5517 | 12.57316 |
February | 672.00000 | 21.21563 | 28.59469 | -0.5060 | 11.78611 |
March | 744.00000 | 21.29241 | 39.06264 | -0.3848 | 9.34811 |
April | 720.00000 | 21.38795 | 45.89440 | -0.2917 | 8.04051 |
May | 744.00000 | 21.55308 | 52.52065 | -1.2998 | 41.44579 |
June | 720.00000 | 21.66980 | 57.81093 | -1.1506 | 34.39384 |
July | 744.00000 | 21.72059 | 57.38708 | -1.0903 | 31.79993 |
August | 744.00000 | 21.72572 | 54.84501 | -1.0725 | 31.34647 |
September | 720.00000 | 21.65861 | 55.26941 | -1.1529 | 34.96947 |
October | 744.00000 | 21.62999 | 49.03830 | -0.1184 | 6.85608 |
November | 720.00000 | 21.34397 | 42.02940 | -0.3553 | 8.80373 |
December | 744.00000 | 21.14097 | 33.86784 | -0.4948 | 11.43695 |
Annual Sum or Average | 8760.00000 | 21.44805 | 45.94413 | -0.7070 | 20.28833 |
Minimum of Months | 672.00000 | 21.02399 | 28.59469 | -1.2998 | 6.85608 |
Maximum of Months | 744.00000 | 21.72572 | 57.81093 | -0.1184 | 41.44579 |
Report: OccupantComfortDataSummaryMonthly
For: BANQUET_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.19242 | 34.09626 | 0.11215 | 6.18785 |
February | 672.00000 | 23.20504 | 30.11950 | 0.08753 | 6.01870 |
March | 744.00000 | 23.56355 | 37.48468 | 0.26338 | 6.99035 |
April | 720.00000 | 23.73441 | 42.64121 | 0.37623 | 8.37093 |
May | 744.00000 | 23.89294 | 49.15882 | -0.3602 | 7.99295 |
June | 720.00000 | 23.96607 | 58.22877 | -0.2106 | 6.04742 |
July | 744.00000 | 23.98800 | 61.58252 | -0.1524 | 5.50228 |
August | 744.00000 | 23.97739 | 58.89836 | -0.1810 | 5.75145 |
September | 720.00000 | 23.92392 | 55.49277 | -0.2794 | 6.87927 |
October | 744.00000 | 23.80680 | 48.24153 | 0.45279 | 9.77816 |
November | 720.00000 | 23.53831 | 39.40601 | 0.26943 | 7.13663 |
December | 744.00000 | 23.35927 | 33.72316 | 0.15994 | 6.17867 |
Annual Sum or Average | 8760.00000 | 23.68168 | 45.84974 | 0.04454 | 6.90790 |
Minimum of Months | 672.00000 | 23.19242 | 30.11950 | -0.3602 | 5.50228 |
Maximum of Months | 744.00000 | 23.98800 | 61.58252 | 0.45279 | 9.77816 |
Report: OccupantComfortDataSummaryMonthly
For: DINING_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.43937 | 33.06591 | 0.21026 | 6.64601 |
February | 672.00000 | 23.44583 | 29.15447 | 0.18372 | 6.36350 |
March | 744.00000 | 23.73495 | 36.41790 | 0.34296 | 7.84256 |
April | 720.00000 | 23.86307 | 41.66830 | 0.44368 | 9.41314 |
May | 744.00000 | 23.95150 | 48.37319 | -0.2918 | 6.97697 |
June | 720.00000 | 23.98570 | 57.68298 | -0.1644 | 5.66984 |
July | 744.00000 | 23.99304 | 61.12513 | -0.1139 | 5.28862 |
August | 744.00000 | 23.98854 | 58.42926 | -0.1409 | 5.47457 |
September | 720.00000 | 23.96276 | 54.84391 | -0.2248 | 6.24667 |
October | 744.00000 | 23.89334 | 47.41251 | 0.50523 | 10.74744 |
November | 720.00000 | 23.71453 | 38.35607 | 0.34978 | 8.00614 |
December | 744.00000 | 23.56578 | 32.64354 | 0.24844 | 6.74038 |
Annual Sum or Average | 8760.00000 | 23.79679 | 45.02563 | 0.11188 | 7.12182 |
Minimum of Months | 672.00000 | 23.43937 | 29.15447 | -0.2918 | 5.28862 |
Maximum of Months | 744.00000 | 23.99304 | 61.12513 | 0.50523 | 10.74744 |
Report: OccupantComfortDataSummaryMonthly
For: KITCHEN_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.65852 | 31.66660 | 0.86958 | 24.17447 |
February | 672.00000 | 23.65225 | 27.74251 | 0.84868 | 23.50118 |
March | 744.00000 | 23.85444 | 35.43397 | 1.00472 | 29.09698 |
April | 720.00000 | 23.87129 | 40.89913 | 1.09346 | 32.59610 |
May | 744.00000 | 23.89127 | 47.56939 | 0.63405 | 18.00069 |
June | 720.00000 | 23.94693 | 56.81201 | 0.77816 | 21.62118 |
July | 744.00000 | 23.96497 | 60.24229 | 0.84449 | 23.47079 |
August | 744.00000 | 23.97543 | 57.52174 | 0.83573 | 23.39124 |
September | 720.00000 | 23.91288 | 53.81657 | 0.71343 | 19.83418 |
October | 744.00000 | 23.88812 | 46.35445 | 1.16224 | 35.50812 |
November | 720.00000 | 23.84579 | 37.40665 | 1.00944 | 29.12857 |
December | 744.00000 | 23.73840 | 31.37506 | 0.90448 | 25.08024 |
Annual Sum or Average | 8760.00000 | 23.85117 | 43.99970 | 0.89181 | 25.46255 |
Minimum of Months | 672.00000 | 23.65225 | 27.74251 | 0.63405 | 18.00069 |
Maximum of Months | 744.00000 | 23.97543 | 60.24229 | 1.16224 | 35.50812 |
Report: OccupantComfortDataSummaryMonthly
For: STORAGE_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.00407 | 28.30132 | -0.5154 | 10.68052 |
February | 672.00000 | 21.00054 | 23.72132 | -0.5418 | 11.21537 |
March | 744.00000 | 21.09081 | 33.38641 | -0.4341 | 9.08776 |
April | 720.00000 | 21.43240 | 39.66965 | -0.3016 | 7.36499 |
May | 744.00000 | 22.17294 | 46.57817 | -1.1530 | 33.44198 |
June | 720.00000 | 23.11535 | 55.44035 | -0.7621 | 17.62188 |
July | 744.00000 | 23.53393 | 58.92921 | -0.5893 | 12.39775 |
August | 744.00000 | 23.56510 | 55.26638 | -0.6019 | 12.79968 |
September | 720.00000 | 22.92733 | 52.11107 | -0.8494 | 20.90926 |
October | 744.00000 | 22.20358 | 44.74040 | -0.0689 | 5.72029 |
November | 720.00000 | 21.25380 | 35.61879 | -0.3777 | 8.28338 |
December | 744.00000 | 21.00723 | 28.36741 | -0.4979 | 10.22619 |
Annual Sum or Average | 8760.00000 | 22.03230 | 41.95080 | -0.5577 | 13.32711 |
Minimum of Months | 672.00000 | 21.00054 | 23.72132 | -1.1530 | 5.72029 |
Maximum of Months | 744.00000 | 23.56510 | 58.92921 | -0.0689 | 33.44198 |
Report: OccupantComfortDataSummaryMonthly
For: CORRIDOR_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.01528 | 31.86563 | -0.4918 | 10.15473 |
February | 672.00000 | 21.02221 | 27.29196 | -0.5099 | 10.49462 |
March | 744.00000 | 21.22305 | 36.68867 | -0.3915 | 8.36024 |
April | 720.00000 | 21.71194 | 42.53516 | -0.2318 | 6.61923 |
May | 744.00000 | 22.45727 | 49.27405 | -1.0659 | 29.49430 |
June | 720.00000 | 23.36030 | 57.60033 | -0.6884 | 15.21845 |
July | 744.00000 | 23.69933 | 60.62349 | -0.5445 | 11.28150 |
August | 744.00000 | 23.79807 | 57.20356 | -0.5304 | 10.98285 |
September | 720.00000 | 23.20860 | 54.46464 | -0.7621 | 18.07997 |
October | 744.00000 | 22.65271 | 47.08644 | 0.03887 | 5.50864 |
November | 720.00000 | 21.36646 | 38.85956 | -0.3460 | 7.90026 |
December | 744.00000 | 21.03285 | 31.85548 | -0.4798 | 9.85444 |
Annual Sum or Average | 8760.00000 | 22.21993 | 44.71365 | -0.5001 | 12.00856 |
Minimum of Months | 672.00000 | 21.01528 | 27.29196 | -1.0659 | 5.50864 |
Maximum of Months | 744.00000 | 23.79807 | 60.62349 | 0.03887 | 29.49430 |
Report: OccupantComfortDataSummaryMonthly
For: CORRIDOR_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.01583 | 29.62811 | -0.4987 | 10.33738 |
February | 672.00000 | 21.03403 | 25.04209 | -0.5151 | 10.65348 |
March | 744.00000 | 21.22155 | 34.45618 | -0.3806 | 8.27752 |
April | 720.00000 | 21.66650 | 40.30892 | -0.2196 | 6.73860 |
May | 744.00000 | 22.46121 | 46.89268 | -1.0117 | 27.55046 |
June | 720.00000 | 23.42978 | 54.83480 | -0.6023 | 13.11867 |
July | 744.00000 | 23.77125 | 57.72879 | -0.4502 | 9.39997 |
August | 744.00000 | 23.76547 | 54.69585 | -0.4693 | 9.87395 |
September | 720.00000 | 23.11640 | 52.23580 | -0.7342 | 17.50904 |
October | 744.00000 | 22.34945 | 45.27417 | -0.0040 | 5.97591 |
November | 720.00000 | 21.24266 | 36.79363 | -0.3638 | 8.09524 |
December | 744.00000 | 21.03609 | 29.61427 | -0.4792 | 9.86126 |
Annual Sum or Average | 8760.00000 | 22.18318 | 42.39278 | -0.4771 | 11.45675 |
Minimum of Months | 672.00000 | 21.01583 | 25.04209 | -1.0117 | 5.97591 |
Maximum of Months | 744.00000 | 23.77125 | 57.72879 | -0.0040 | 27.55046 |
Report: OccupantComfortDataSummaryMonthly
For: MECH_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.03291 | 27.81534 | -0.4925 | 10.21998 |
February | 672.00000 | 21.02490 | 23.26489 | -0.5209 | 10.76358 |
March | 744.00000 | 21.20475 | 32.71339 | -0.3981 | 8.53385 |
April | 720.00000 | 21.59868 | 38.81232 | -0.2553 | 6.89484 |
May | 744.00000 | 22.37230 | 45.49685 | -1.0759 | 30.00401 |
June | 720.00000 | 23.28490 | 54.18166 | -0.6924 | 15.52994 |
July | 744.00000 | 23.64270 | 57.62753 | -0.5381 | 11.20471 |
August | 744.00000 | 23.66388 | 54.13000 | -0.5528 | 11.60959 |
September | 720.00000 | 23.09901 | 50.95365 | -0.7794 | 18.54288 |
October | 744.00000 | 22.38570 | 43.74443 | -0.0199 | 5.64405 |
November | 720.00000 | 21.39522 | 34.82794 | -0.3359 | 7.75506 |
December | 744.00000 | 21.05365 | 27.85889 | -0.4736 | 9.74845 |
Annual Sum or Average | 8760.00000 | 22.15360 | 41.05661 | -0.5111 | 12.21635 |
Minimum of Months | 672.00000 | 21.02490 | 23.26489 | -1.0759 | 5.64405 |
Maximum of Months | 744.00000 | 23.66388 | 57.62753 | -0.0199 | 30.00401 |
Report: ChillerReportMonthly
For: COOLSYS1 CHILLER1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCHILLER ELECTRICITY ENERGY [J] | CHILLER ELECTRICITY RATE {Maximum} [W] | CHILLER ELECTRICITY RATE {TIMESTAMP} | CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | CHILLER EVAPORATOR COOLING ENERGY [J] | CHILLER EVAPORATOR COOLING RATE [] | CHILLER CONDENSER HEAT TRANSFER ENERGY [J] | CHILLER COP [W/W] | CHILLER COP {Maximum} [W/W] | CHILLER COP {TIMESTAMP} | CHILLER PART LOAD RATIO [] | CHILLER PART LOAD RATIO [] | |
January | 0.162124E+10 | 15333.43 | 13-JAN-09:04 | 220.41 | 0.516597E+10 | 0.00 | 0.678721E+10 | 0.94 | 3.19 | 05-JAN-12:50 | 0.00 | 0.00 |
February | 0.203932E+10 | 16601.19 | 16-FEB-09:04 | 230.26 | 0.649817E+10 | 0.00 | 0.853749E+10 | 1.09 | 3.19 | 02-FEB-12:43 | 0.00 | 0.00 |
March | 0.624398E+10 | 74919.30 | 27-MAR-15:02 | 366.85 | 0.193101E+11 | 0.00 | 0.255541E+11 | 1.56 | 3.23 | 27-MAR-15:02 | 0.00 | 0.00 |
April | 0.256396E+11 | 112668.82 | 07-APR-15:03 | 500.51 | 0.764888E+11 | 0.00 | 0.102128E+12 | 2.17 | 3.53 | 07-APR-18:03 | 0.00 | 0.00 |
May | 0.754869E+11 | 127092.04 | 31-MAY-18:03 | 719.14 | 0.226108E+12 | 0.00 | 0.301595E+12 | 2.95 | 4.09 | 31-MAY-18:03 | 0.00 | 0.00 |
June | 0.220917E+12 | 194312.14 | 19-JUN-18:03 | 720.00 | 0.751385E+12 | 0.00 | 0.972303E+12 | 3.31 | 4.20 | 24-JUN-18:03 | 0.00 | 0.00 |
July | 0.320858E+12 | 188935.01 | 20-JUL-18:03 | 744.00 | 0.113257E+13 | 0.00 | 0.145343E+13 | 3.52 | 4.23 | 23-JUL-18:03 | 0.00 | 0.00 |
August | 0.287349E+12 | 209420.06 | 16-AUG-15:03 | 744.00 | 0.961589E+12 | 0.00 | 0.124894E+13 | 3.29 | 4.19 | 06-AUG-18:02 | 0.00 | 0.00 |
September | 0.165822E+12 | 164209.56 | 07-SEP-20:40 | 718.79 | 0.546447E+12 | 0.00 | 0.712269E+12 | 3.17 | 4.23 | 22-SEP-18:02 | 0.00 | 0.00 |
October | 0.731971E+11 | 126761.44 | 04-OCT-15:03 | 688.33 | 0.232261E+12 | 0.00 | 0.305458E+12 | 2.90 | 4.17 | 05-OCT-18:02 | 0.00 | 0.00 |
November | 0.697494E+10 | 46806.36 | 04-NOV-15:01 | 383.01 | 0.217679E+11 | 0.00 | 0.287428E+11 | 1.69 | 3.19 | 01-NOV-06:10 | 0.00 | 0.00 |
December | 0.304899E+10 | 18310.07 | 17-DEC-16:04 | 312.38 | 0.971540E+10 | 0.00 | 0.127644E+11 | 1.34 | 3.19 | 01-DEC-16:06 | 0.00 | 0.00 |
Annual Sum or Average | 0.118920E+13 | 6347.69 | 0.398931E+13 | 0.00 | 0.517851E+13 | 2.33 | 0.00 | 0.00 | ||||
Minimum of Months | 0.162124E+10 | 15333.43 | 220.41 | 0.516597E+10 | 0.00 | 0.678721E+10 | 0.94 | 3.19 | 0.00 | 0.00 | ||
Maximum of Months | 0.320858E+12 | 209420.06 | 744.00 | 0.113257E+13 | 0.00 | 0.145343E+13 | 3.52 | 4.23 | 0.00 | 0.00 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum} [] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.142967E+12 | 0.00 | 744.00 | 244134.17 | 02-JAN-09:03 | 0.00 | 51.36 | 80.87 | 0.43 | 0.00 | 0.11 | 0.50 | 02-JAN-09:03 |
February | 0.121360E+12 | 0.00 | 671.93 | 250248.53 | 06-FEB-09:01 | 0.00 | 52.31 | 81.06 | 0.40 | 0.00 | 0.10 | 0.51 | 06-FEB-09:01 |
March | 0.581199E+11 | 0.00 | 725.08 | 188916.36 | 31-MAR-15:01 | 0.00 | 52.23 | 79.35 | 0.20 | 0.00 | 0.04 | 0.39 | 31-MAR-15:01 |
April | 0.356546E+11 | 0.00 | 552.30 | 179631.66 | 21-APR-15:01 | 0.00 | 45.03 | 70.64 | 0.11 | 0.00 | 0.03 | 0.37 | 21-APR-15:01 |
May | 0.847328E+10 | 0.00 | 294.09 | 121348.43 | 15-MAY-02:45 | 0.00 | 41.86 | 56.05 | 0.02 | 0.00 | 0.01 | 0.25 | 15-MAY-02:45 |
June | 0.260198E+09 | 0.00 | 14.14 | 42838.50 | 06-JUN-15:05 | 0.00 | 48.25 | 48.97 | 0.00 | 0.00 | 0.00 | 0.09 | 06-JUN-15:05 |
July | 57763819.46 | 0.00 | 2.54 | 22033.06 | 14-JUL-08:07 | 0.00 | 53.85 | 53.94 | 0.00 | 0.00 | 0.00 | 0.04 | 14-JUL-08:07 |
August | 0.298431E+09 | 0.00 | 13.81 | 43179.12 | 30-AUG-08:05 | 0.00 | 48.13 | 48.74 | 0.00 | 0.00 | 0.00 | 0.09 | 30-AUG-08:05 |
September | 0.168547E+10 | 0.00 | 112.44 | 58380.05 | 24-SEP-05:16 | 0.00 | 53.19 | 57.34 | 0.00 | 0.00 | 0.00 | 0.12 | 24-SEP-05:16 |
October | 0.165279E+11 | 0.00 | 370.51 | 141585.99 | 26-OCT-23:27 | 0.00 | 48.14 | 64.19 | 0.05 | 0.00 | 0.01 | 0.29 | 26-OCT-23:27 |
November | 0.619180E+11 | 0.00 | 687.15 | 203416.42 | 27-NOV-16:01 | 0.00 | 51.37 | 78.59 | 0.21 | 0.00 | 0.05 | 0.41 | 27-NOV-16:01 |
December | 0.878531E+11 | 0.00 | 743.91 | 192608.75 | 04-DEC-19:01 | 0.00 | 54.19 | 80.52 | 0.31 | 0.00 | 0.07 | 0.39 | 04-DEC-19:01 |
Annual Sum or Average | 0.535176E+12 | 0.00 | 4931.90 | 0.00 | 49.98 | 66.60 | 0.14 | 0.00 | 0.03 | ||||
Minimum of Months | 57763819.46 | 0.00 | 2.54 | 22033.06 | 0.00 | 41.86 | 48.74 | 0.00 | 0.00 | 0.00 | 0.04 | ||
Maximum of Months | 0.142967E+12 | 0.00 | 744.00 | 250248.53 | 0.00 | 54.19 | 81.06 | 0.43 | 0.00 | 0.11 | 0.51 |
Report: DXReportMonthly
For: VAV WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.227956E+09 | 0.00 | 138.31 | 0.227956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28016.06 | 12-JAN-22:44 | 28016.06 | 12-JAN-22:44 | 0.00 | 0.00 | 0.00 |
February | 0.207446E+09 | 0.00 | 123.71 | 0.207446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14207.43 | 28-FEB-21:59 | 14207.43 | 28-FEB-21:59 | 0.00 | 0.00 | 0.00 |
March | 0.355282E+10 | 0.00 | 153.29 | 0.352241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 130064.22 | 27-MAR-16:00 | 130064.22 | 27-MAR-16:00 | 0.00 | 0.00 | 0.00 |
April | 0.341923E+11 | 0.00 | 252.63 | 0.339495E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 210145.33 | 09-APR-10:50 | 205181.39 | 07-APR-17:04 | 0.00 | 0.00 | 0.00 |
May | 0.126129E+12 | 0.00 | 486.96 | 0.108859E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 291468.15 | 31-MAY-17:17 | 222435.02 | 29-MAY-12:25 | 0.00 | 0.00 | 0.00 |
June | 0.519220E+12 | 0.00 | 707.92 | 0.312368E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 471839.16 | 24-JUN-17:12 | 301944.59 | 22-JUN-18:20 | 0.00 | 0.00 | 0.00 |
July | 0.817177E+12 | 0.00 | 744.00 | 0.447467E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 489707.03 | 27-JUL-21:00 | 283289.18 | 11-JUL-18:03 | 0.00 | 0.00 | 0.00 |
August | 0.666890E+12 | 0.00 | 744.00 | 0.440176E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 505719.26 | 11-AUG-22:00 | 353485.27 | 24-AUG-18:30 | 0.00 | 0.00 | 0.00 |
September | 0.362678E+12 | 0.00 | 652.35 | 0.251324E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 479564.58 | 13-SEP-21:00 | 296392.49 | 01-SEP-20:30 | 0.00 | 0.00 | 0.00 |
October | 0.125687E+12 | 0.00 | 410.24 | 0.811245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 287726.08 | 05-OCT-19:10 | 181628.31 | 25-OCT-10:33 | 0.00 | 0.00 | 0.00 |
November | 0.359820E+10 | 0.00 | 164.09 | 0.330487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63869.16 | 04-NOV-10:50 | 63869.16 | 04-NOV-10:50 | 0.00 | 0.00 | 0.00 |
December | 0.459344E+09 | 0.00 | 206.18 | 0.459344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30701.03 | 03-DEC-20:45 | 30701.03 | 03-DEC-20:45 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.266002E+13 | 0.00 | 4783.68 | 0.168299E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.207446E+09 | 0.00 | 123.71 | 0.207446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14207.43 | 14207.43 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.817177E+12 | 0.00 | 744.00 | 0.447467E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 505719.26 | 353485.27 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: FLR_3_DOAS COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 |
March | 0.697382E+09 | 0.00 | 19.92 | 0.589145E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 32906.47 | 27-MAR-13:00 | 25442.26 | 27-MAR-16:00 | 0.00 | 0.00 | 0.00 |
April | 0.634269E+10 | 0.00 | 144.69 | 0.616737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40374.02 | 09-APR-11:00 | 29723.00 | 07-APR-13:00 | 0.00 | 0.00 | 0.00 |
May | 0.232123E+11 | 0.00 | 446.03 | 0.196119E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 51821.69 | 31-MAY-17:06 | 32643.06 | 30-MAY-13:00 | 0.00 | 0.00 | 0.00 |
June | 0.961906E+11 | 0.00 | 707.83 | 0.555096E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 79002.93 | 24-JUN-17:25 | 37360.91 | 19-JUN-12:00 | 0.00 | 0.00 | 0.00 |
July | 0.130865E+12 | 0.00 | 744.00 | 0.745834E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 77079.99 | 23-JUL-14:20 | 35565.34 | 07-JUL-12:00 | 0.00 | 0.00 | 0.00 |
August | 0.107294E+12 | 0.00 | 744.00 | 0.710766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 73614.51 | 06-AUG-07:17 | 35442.98 | 24-AUG-15:00 | 0.00 | 0.00 | 0.00 |
September | 0.663363E+11 | 0.00 | 641.83 | 0.447544E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 76059.89 | 22-SEP-17:30 | 33319.71 | 01-SEP-14:00 | 0.00 | 0.00 | 0.00 |
October | 0.245200E+11 | 0.00 | 337.89 | 0.147924E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52292.02 | 24-OCT-14:00 | 28849.49 | 04-OCT-13:00 | 0.00 | 0.00 | 0.00 |
November | 0.605095E+09 | 0.00 | 33.17 | 0.541138E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12351.77 | 10-NOV-08:00 | 10814.14 | 04-NOV-13:00 | 0.00 | 0.00 | 0.00 |
December | 2300.65 | 0.00 | 0.02 | 2300.65 | 0.00 | 0.00 | 0.00 | 0.00 | 34.51 | 04-DEC-21:10 | 34.51 | 04-DEC-21:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.456064E+12 | 0.00 | 3819.38 | 0.287626E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.130865E+12 | 0.00 | 744.00 | 0.745834E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 79002.93 | 37360.91 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_1_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 42773173.65 | 0.00 | 9.81 | 41754485.90 | 0.00 | 0.00 | 0.00 | 0.00 | 13495.69 | 17-JAN-16:02 | 13495.69 | 17-JAN-16:02 | 0.00 | 0.00 | 0.00 |
February | 0.116071E+09 | 0.00 | 20.39 | 0.116007E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13498.30 | 20-FEB-16:02 | 13498.30 | 20-FEB-16:02 | 0.00 | 0.00 | 0.00 |
March | 0.814529E+09 | 0.00 | 117.95 | 0.756171E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14380.44 | 27-MAR-15:02 | 13502.96 | 29-MAR-15:02 | 0.00 | 0.00 | 0.00 |
April | 0.213957E+10 | 0.00 | 289.33 | 0.156050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14069.37 | 10-APR-15:02 | 14069.37 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.457448E+10 | 0.00 | 552.68 | 0.317833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15534.62 | 18-MAY-15:02 | 14344.02 | 20-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.901664E+10 | 0.00 | 656.55 | 0.535116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18881.22 | 27-JUN-08:62 | 14419.37 | 15-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.116257E+11 | 0.00 | 701.11 | 0.698409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18931.26 | 30-JUL-08:62 | 14562.71 | 07-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.122018E+11 | 0.00 | 703.89 | 0.801563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18177.60 | 27-AUG-08:62 | 14445.03 | 02-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.699127E+10 | 0.00 | 625.38 | 0.425074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19228.94 | 22-SEP-18:02 | 14508.73 | 07-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.448725E+10 | 0.00 | 524.90 | 0.286025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16562.04 | 05-OCT-18:02 | 13691.80 | 02-OCT-18:02 | 0.00 | 0.00 | 0.00 |
November | 0.361447E+09 | 0.00 | 95.56 | 0.283646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13696.27 | 03-NOV-15:02 | 13696.27 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 50638906.34 | 0.00 | 14.15 | 50096024.44 | 0.00 | 0.00 | 0.00 | 0.00 | 13434.86 | 17-DEC-16:01 | 13434.86 | 17-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.524221E+11 | 0.00 | 4311.68 | 0.334484E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 42773173.65 | 0.00 | 9.81 | 41754485.90 | 0.00 | 0.00 | 0.00 | 0.00 | 13434.86 | 13434.86 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.122018E+11 | 0.00 | 703.89 | 0.801563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19228.94 | 14562.71 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 8835162.58 | 0.00 | 1.53 | 7858671.06 | 0.00 | 0.00 | 0.00 | 0.00 | 7460.77 | 17-JAN-16:02 | 7460.77 | 17-JAN-16:02 | 0.00 | 0.00 | 0.00 |
February | 18847774.53 | 0.00 | 6.06 | 18771190.86 | 0.00 | 0.00 | 0.00 | 0.00 | 12121.39 | 20-FEB-16:02 | 12121.39 | 20-FEB-16:02 | 0.00 | 0.00 | 0.00 |
March | 0.364371E+09 | 0.00 | 57.79 | 0.328886E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13522.11 | 27-MAR-15:02 | 13092.28 | 07-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.147966E+10 | 0.00 | 227.88 | 0.104669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13646.92 | 10-APR-15:02 | 13646.92 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.409612E+10 | 0.00 | 521.73 | 0.280103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15027.43 | 18-MAY-15:02 | 13914.03 | 20-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.862299E+10 | 0.00 | 648.98 | 0.510424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18286.21 | 27-JUN-08:62 | 13987.03 | 15-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.110843E+11 | 0.00 | 697.37 | 0.659705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18380.73 | 30-JUL-08:62 | 14118.29 | 07-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.108497E+11 | 0.00 | 693.94 | 0.687075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17679.79 | 27-AUG-08:62 | 14185.70 | 12-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.547440E+10 | 0.00 | 579.95 | 0.306363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18637.62 | 22-SEP-18:02 | 14002.42 | 01-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.246441E+10 | 0.00 | 394.02 | 0.136717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15492.37 | 05-OCT-18:02 | 13537.15 | 03-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 80861084.93 | 0.00 | 25.52 | 66294791.70 | 0.00 | 0.00 | 0.00 | 0.00 | 13285.58 | 03-NOV-15:02 | 13285.58 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 6128130.11 | 0.00 | 0.95 | 5630201.85 | 0.00 | 0.00 | 0.00 | 0.00 | 4554.49 | 17-DEC-19:03 | 4554.49 | 17-DEC-19:03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.445506E+11 | 0.00 | 3855.72 | 0.272780E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 6128130.11 | 0.00 | 0.95 | 5630201.85 | 0.00 | 0.00 | 0.00 | 0.00 | 4554.49 | 4554.49 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.110843E+11 | 0.00 | 697.37 | 0.687075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18637.62 | 14185.70 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.123189E+09 | 0.00 | 7.94 | 0.123189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7563.27 | 19-JAN-14:40 | 7563.27 | 19-JAN-14:40 | 0.00 | 0.00 | 0.00 |
February | 0.814508E+09 | 0.00 | 26.68 | 0.814508E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17093.77 | 20-FEB-13:23 | 17093.77 | 20-FEB-13:23 | 0.00 | 0.00 | 0.00 |
March | 0.258465E+10 | 0.00 | 69.57 | 0.257064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30352.29 | 03-MAR-13:30 | 30352.29 | 03-MAR-13:30 | 0.00 | 0.00 | 0.00 |
April | 0.601189E+10 | 0.00 | 132.03 | 0.452566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39540.94 | 08-APR-12:30 | 36068.39 | 07-APR-13:00 | 0.00 | 0.00 | 0.00 |
May | 0.954621E+10 | 0.00 | 271.16 | 0.694827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30973.35 | 31-MAY-12:30 | 23561.44 | 30-MAY-12:50 | 0.00 | 0.00 | 0.00 |
June | 0.213051E+11 | 0.00 | 458.78 | 0.996113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35298.71 | 19-JUN-12:50 | 27245.40 | 19-JUN-13:20 | 0.00 | 0.00 | 0.00 |
July | 0.388565E+11 | 0.00 | 666.69 | 0.189783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37812.58 | 08-JUL-12:10 | 30731.19 | 10-JUL-13:10 | 0.00 | 0.00 | 0.00 |
August | 0.478974E+11 | 0.00 | 696.41 | 0.285532E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 45562.27 | 16-AUG-14:50 | 37415.05 | 30-AUG-13:30 | 0.00 | 0.00 | 0.00 |
September | 0.304814E+11 | 0.00 | 501.94 | 0.198099E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 50077.34 | 30-SEP-12:30 | 48431.08 | 30-SEP-12:50 | 0.00 | 0.00 | 0.00 |
October | 0.305560E+11 | 0.00 | 437.27 | 0.239748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 54513.71 | 04-OCT-12:00 | 49230.71 | 30-OCT-13:20 | 0.00 | 0.00 | 0.00 |
November | 0.557547E+10 | 0.00 | 110.65 | 0.532256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43745.13 | 02-NOV-12:50 | 43745.13 | 02-NOV-12:50 | 0.00 | 0.00 | 0.00 |
December | 0.214862E+10 | 0.00 | 45.18 | 0.214862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30820.04 | 17-DEC-13:40 | 30820.04 | 17-DEC-13:40 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.195901E+12 | 0.00 | 3424.30 | 0.123731E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.123189E+09 | 0.00 | 7.94 | 0.123189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7563.27 | 7563.27 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.478974E+11 | 0.00 | 696.41 | 0.285532E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 54513.71 | 49230.71 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.120826E+09 | 0.00 | 9.00 | 79896470.38 | 0.00 | 0.00 | 0.00 | 0.00 | 43724.31 | 03-JAN-19:03 | 41427.88 | 03-JAN-19:03 | 0.00 | 0.00 | 0.00 |
February | 54776754.09 | 0.00 | 1.53 | 54776754.09 | 0.00 | 0.00 | 0.00 | 0.00 | 40768.03 | 01-FEB-19:03 | 40768.03 | 01-FEB-19:03 | 0.00 | 0.00 | 0.00 |
March | 0.152831E+10 | 0.00 | 100.95 | 0.109903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62586.23 | 28-MAR-18:02 | 62586.23 | 28-MAR-18:02 | 0.00 | 0.00 | 0.00 |
April | 0.999686E+10 | 0.00 | 329.23 | 0.625558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68282.57 | 08-APR-15:02 | 68282.57 | 08-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.298417E+11 | 0.00 | 522.50 | 0.203196E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 81769.96 | 31-MAY-18:02 | 72889.82 | 29-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.529524E+11 | 0.00 | 519.74 | 0.325324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 100007.38 | 27-JUN-08:62 | 73694.59 | 20-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.668572E+11 | 0.00 | 564.41 | 0.426349E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 100848.22 | 30-JUL-08:62 | 74218.87 | 11-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.585720E+11 | 0.00 | 552.91 | 0.378434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 95871.55 | 06-AUG-08:62 | 74232.65 | 22-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.353832E+11 | 0.00 | 506.78 | 0.201302E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 102790.43 | 22-SEP-18:02 | 72819.62 | 01-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.151273E+11 | 0.00 | 435.97 | 0.750615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 80764.54 | 05-OCT-18:02 | 65144.70 | 04-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.215206E+10 | 0.00 | 145.23 | 0.133799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63042.10 | 05-NOV-08:62 | 63042.10 | 05-NOV-08:62 | 0.00 | 0.00 | 0.00 |
December | 0.116948E+09 | 0.00 | 6.48 | 0.107466E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 31687.95 | 29-DEC-19:04 | 31687.95 | 29-DEC-19:04 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.272704E+12 | 0.00 | 3694.74 | 0.169901E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 54776754.09 | 0.00 | 1.53 | 54776754.09 | 0.00 | 0.00 | 0.00 | 0.00 | 31687.95 | 31687.95 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.668572E+11 | 0.00 | 564.41 | 0.426349E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 102790.43 | 74232.65 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_5_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 81009770.63 | 0.00 | 17.25 | 80064473.08 | 0.00 | 0.00 | 0.00 | 0.00 | 10932.81 | 19-JAN-09:01 | 10932.81 | 19-JAN-09:01 | 0.00 | 0.00 | 0.00 |
February | 0.127168E+09 | 0.00 | 25.57 | 0.127112E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11864.33 | 25-FEB-09:01 | 11864.33 | 25-FEB-09:01 | 0.00 | 0.00 | 0.00 |
March | 0.671305E+09 | 0.00 | 121.65 | 0.634803E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12622.56 | 27-MAR-15:02 | 12336.09 | 03-MAR-09:02 | 0.00 | 0.00 | 0.00 |
April | 0.215556E+10 | 0.00 | 314.89 | 0.153309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12845.27 | 10-APR-15:02 | 12845.27 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.477714E+10 | 0.00 | 565.24 | 0.337386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14480.16 | 31-MAY-18:02 | 13095.38 | 20-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.849075E+10 | 0.00 | 666.66 | 0.496273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16811.57 | 21-JUN-18:02 | 13274.37 | 23-JUN-08:62 | 0.00 | 0.00 | 0.00 |
July | 0.114733E+11 | 0.00 | 713.30 | 0.686222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17021.36 | 30-JUL-08:62 | 13154.56 | 13-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.120791E+11 | 0.00 | 721.38 | 0.790925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16208.78 | 06-AUG-08:62 | 13211.00 | 02-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.706971E+10 | 0.00 | 641.82 | 0.433513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17558.22 | 22-SEP-18:02 | 13282.84 | 07-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.429773E+10 | 0.00 | 536.61 | 0.271408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14997.85 | 05-OCT-18:02 | 12777.14 | 03-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.535234E+09 | 0.00 | 115.65 | 0.437506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12504.88 | 03-NOV-15:02 | 12504.88 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 0.145900E+09 | 0.00 | 29.25 | 0.141820E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11794.94 | 17-DEC-09:01 | 11794.94 | 17-DEC-09:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.519039E+11 | 0.00 | 4469.27 | 0.331117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 81009770.63 | 0.00 | 17.25 | 80064473.08 | 0.00 | 0.00 | 0.00 | 0.00 | 10932.81 | 10932.81 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.120791E+11 | 0.00 | 721.38 | 0.790925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17558.22 | 13282.84 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_6_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 9518493.76 | 0.00 | 3.15 | 8663992.49 | 0.00 | 0.00 | 0.00 | 0.00 | 4711.70 | 24-JAN-19:04 | 4213.35 | 26-JAN-09:03 | 0.00 | 0.00 | 0.00 |
February | 18186644.54 | 0.00 | 6.57 | 18156523.46 | 0.00 | 0.00 | 0.00 | 0.00 | 9493.41 | 19-FEB-09:01 | 9493.41 | 19-FEB-09:01 | 0.00 | 0.00 | 0.00 |
March | 0.252296E+09 | 0.00 | 53.75 | 0.233750E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11981.71 | 03-MAR-09:02 | 11981.71 | 03-MAR-09:02 | 0.00 | 0.00 | 0.00 |
April | 0.144536E+10 | 0.00 | 251.57 | 0.990257E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12482.92 | 09-APR-15:02 | 12477.33 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.425831E+10 | 0.00 | 547.97 | 0.295713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13857.10 | 18-MAY-15:02 | 12789.55 | 31-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.807934E+10 | 0.00 | 663.69 | 0.470656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16302.50 | 21-JUN-18:02 | 12975.69 | 07-JUN-18:02 | 0.00 | 0.00 | 0.00 |
July | 0.109252E+11 | 0.00 | 712.16 | 0.644854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16557.90 | 30-JUL-08:62 | 12915.51 | 07-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.107131E+11 | 0.00 | 717.62 | 0.667766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16142.21 | 06-AUG-08:62 | 12830.38 | 13-AUG-08:62 | 0.00 | 0.00 | 0.00 |
September | 0.550850E+10 | 0.00 | 614.67 | 0.313846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17043.29 | 22-SEP-18:02 | 12974.82 | 01-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.223169E+10 | 0.00 | 383.44 | 0.123375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14776.48 | 25-OCT-08:62 | 11997.93 | 02-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.157155E+09 | 0.00 | 43.00 | 0.116888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10946.07 | 06-NOV-09:02 | 10946.07 | 06-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 11629740.17 | 0.00 | 5.02 | 11261315.91 | 0.00 | 0.00 | 0.00 | 0.00 | 3902.90 | 09-DEC-09:03 | 3902.90 | 09-DEC-09:03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.436103E+11 | 0.00 | 4002.60 | 0.265411E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 9518493.76 | 0.00 | 3.15 | 8663992.49 | 0.00 | 0.00 | 0.00 | 0.00 | 3902.90 | 3902.90 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.109252E+11 | 0.00 | 717.62 | 0.667766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17043.29 | 12975.69 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_1_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 11597952.98 | 0.00 | 7.95 | 11282813.33 | 0.00 | 0.00 | 0.00 | 0.00 | 3541.01 | 17-JAN-16:02 | 3541.01 | 17-JAN-16:02 | 0.00 | 0.00 | 0.00 |
February | 29898443.97 | 0.00 | 18.29 | 29859265.87 | 0.00 | 0.00 | 0.00 | 0.00 | 3541.70 | 20-FEB-16:02 | 3541.70 | 20-FEB-16:02 | 0.00 | 0.00 | 0.00 |
March | 0.203734E+09 | 0.00 | 99.08 | 0.189028E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3797.28 | 27-MAR-15:02 | 3543.92 | 29-MAR-18:02 | 0.00 | 0.00 | 0.00 |
April | 0.526167E+09 | 0.00 | 249.42 | 0.397838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3691.48 | 10-APR-15:02 | 3691.48 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.111371E+10 | 0.00 | 495.03 | 0.803077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4143.73 | 31-MAY-08:62 | 3763.42 | 20-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.225745E+10 | 0.00 | 655.59 | 0.133289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5142.55 | 27-JUN-08:62 | 3822.97 | 19-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.297448E+10 | 0.00 | 700.57 | 0.177382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5192.21 | 30-JUL-08:62 | 3789.70 | 07-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.309870E+10 | 0.00 | 702.45 | 0.201853E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4981.70 | 27-AUG-08:62 | 3810.67 | 03-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.167196E+10 | 0.00 | 584.25 | 0.101370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5217.02 | 22-SEP-18:02 | 3826.58 | 14-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.990745E+09 | 0.00 | 439.71 | 0.636464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4433.72 | 05-OCT-18:02 | 3592.81 | 02-OCT-18:02 | 0.00 | 0.00 | 0.00 |
November | 67547344.21 | 0.00 | 61.56 | 55227836.72 | 0.00 | 0.00 | 0.00 | 0.00 | 3593.58 | 03-NOV-15:02 | 3593.58 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 11437305.67 | 0.00 | 8.39 | 11281907.28 | 0.00 | 0.00 | 0.00 | 0.00 | 3540.21 | 17-DEC-16:01 | 3540.21 | 17-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.129574E+11 | 0.00 | 4022.30 | 0.827300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 11437305.67 | 0.00 | 7.95 | 11281907.28 | 0.00 | 0.00 | 0.00 | 0.00 | 3540.21 | 3540.21 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.309870E+10 | 0.00 | 702.45 | 0.201853E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5217.02 | 3826.58 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 2828151.59 | 0.00 | 1.62 | 2527977.89 | 0.00 | 0.00 | 0.00 | 0.00 | 1134.88 | 23-JAN-19:04 | 982.02 | 20-JAN-16:02 | 0.00 | 0.00 | 0.00 |
February | 3468788.35 | 0.00 | 4.19 | 3432166.88 | 0.00 | 0.00 | 0.00 | 0.00 | 2467.47 | 20-FEB-16:02 | 2467.47 | 20-FEB-16:02 | 0.00 | 0.00 | 0.00 |
March | 84507225.04 | 0.00 | 47.35 | 75442682.21 | 0.00 | 0.00 | 0.00 | 0.00 | 3546.50 | 27-MAR-15:02 | 3426.73 | 11-MAR-16:02 | 0.00 | 0.00 | 0.00 |
April | 0.356736E+09 | 0.00 | 188.24 | 0.263281E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3591.99 | 16-APR-18:02 | 3591.99 | 16-APR-18:02 | 0.00 | 0.00 | 0.00 |
May | 0.985549E+09 | 0.00 | 464.45 | 0.700930E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3989.40 | 31-MAY-08:62 | 3643.04 | 20-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.215412E+10 | 0.00 | 649.59 | 0.126552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4973.87 | 27-JUN-08:62 | 3646.36 | 02-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.283332E+10 | 0.00 | 697.21 | 0.166990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5030.61 | 30-JUL-08:62 | 3675.89 | 07-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.274168E+10 | 0.00 | 693.83 | 0.172027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4813.87 | 27-AUG-08:62 | 3684.23 | 04-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.127207E+10 | 0.00 | 525.45 | 0.709840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5046.91 | 22-SEP-18:02 | 3645.20 | 01-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.495607E+09 | 0.00 | 289.55 | 0.285122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4141.58 | 05-OCT-18:02 | 3560.76 | 03-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 14855461.42 | 0.00 | 13.28 | 13146505.72 | 0.00 | 0.00 | 0.00 | 0.00 | 3449.67 | 03-NOV-15:02 | 3449.67 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 3176098.86 | 0.00 | 1.62 | 3040947.07 | 0.00 | 0.00 | 0.00 | 0.00 | 1115.01 | 08-DEC-16:03 | 1115.01 | 08-DEC-16:03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.109479E+11 | 0.00 | 3576.38 | 0.671245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2828151.59 | 0.00 | 1.62 | 2527977.89 | 0.00 | 0.00 | 0.00 | 0.00 | 1115.01 | 982.02 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.283332E+10 | 0.00 | 697.21 | 0.172027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5046.91 | 3684.23 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.876715E+09 | 0.00 | 89.34 | 0.875637E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16313.45 | 17-JAN-16:02 | 16313.45 | 17-JAN-16:02 | 0.00 | 0.00 | 0.00 |
February | 0.129096E+10 | 0.00 | 137.82 | 0.129081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16316.88 | 20-FEB-16:02 | 16316.88 | 20-FEB-16:02 | 0.00 | 0.00 | 0.00 |
March | 0.244458E+10 | 0.00 | 222.22 | 0.230192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17177.87 | 27-MAR-15:02 | 16325.10 | 28-MAR-15:02 | 0.00 | 0.00 | 0.00 |
April | 0.347770E+10 | 0.00 | 333.88 | 0.260216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17004.97 | 10-APR-15:02 | 17004.97 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.548088E+10 | 0.00 | 545.96 | 0.370435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20114.29 | 31-MAY-18:02 | 17344.91 | 10-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.105766E+11 | 0.00 | 637.66 | 0.583795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24173.56 | 27-JUN-08:62 | 17645.67 | 22-JUN-18:02 | 0.00 | 0.00 | 0.00 |
July | 0.146900E+11 | 0.00 | 690.34 | 0.863362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24194.19 | 30-JUL-08:62 | 17532.67 | 16-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.160992E+11 | 0.00 | 699.65 | 0.105282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 23130.48 | 27-AUG-08:62 | 17620.92 | 18-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.112189E+11 | 0.00 | 633.86 | 0.726285E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24643.94 | 22-SEP-18:02 | 17381.28 | 01-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.982079E+10 | 0.00 | 592.24 | 0.724863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20732.55 | 05-OCT-18:02 | 16937.57 | 05-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.227208E+10 | 0.00 | 224.51 | 0.197977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16554.48 | 03-NOV-15:02 | 16554.48 | 03-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 0.156237E+10 | 0.00 | 136.88 | 0.155626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16312.71 | 03-DEC-16:02 | 16312.71 | 03-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.798107E+11 | 0.00 | 4944.35 | 0.538221E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.876715E+09 | 0.00 | 89.34 | 0.875637E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16312.71 | 16312.71 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.160992E+11 | 0.00 | 699.65 | 0.105282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 24643.94 | 17645.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 701.21 | 460.14 | 241.07 | 679.60 | 627.85 | 0.00 | 0.00 | 0.00 |
February | 927.98 | 616.76 | 311.22 | 916.07 | 621.23 | 0.00 | 0.00 | 0.00 |
March | 822.19 | 452.60 | 369.58 | 859.05 | 441.64 | 0.00 | 0.00 | 0.00 |
April | 654.44 | 264.77 | 389.67 | 720.61 | 311.18 | 0.00 | 0.00 | 0.00 |
May | 562.08 | 115.08 | 447.01 | 670.77 | 178.61 | 0.00 | 0.00 | 0.00 |
June | 530.75 | 81.78 | 448.97 | 721.13 | 85.70 | 0.00 | 0.00 | 0.00 |
July | 552.24 | 93.21 | 459.04 | 820.57 | 36.90 | 0.00 | 0.00 | 0.00 |
August | 739.68 | 272.86 | 466.82 | 1086.32 | 64.97 | 0.00 | 0.00 | 0.00 |
September | 780.56 | 391.91 | 388.65 | 1029.02 | 137.01 | 0.00 | 0.00 | 0.00 |
October | 1103.06 | 691.71 | 411.35 | 1343.67 | 282.19 | 0.00 | 0.00 | 0.00 |
November | 763.80 | 458.18 | 305.62 | 801.95 | 436.38 | 0.00 | 0.00 | 0.00 |
December | 757.58 | 538.07 | 219.51 | 763.09 | 564.69 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 740.41 | 368.50 | 371.91 | 867.80 | 313.98 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 530.75 | 81.78 | 219.51 | 670.77 | 36.90 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1103.06 | 691.71 | 466.82 | 1343.67 | 627.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1974.55 | 1295.73 | 678.82 | 1890.77 | 1822.60 | 0.00 | 0.00 | 0.00 |
February | 2613.12 | 1736.75 | 876.37 | 2547.67 | 1808.21 | 0.00 | 0.00 | 0.00 |
March | 2315.23 | 1274.50 | 1040.72 | 2386.24 | 1325.27 | 0.00 | 0.00 | 0.00 |
April | 1842.86 | 745.58 | 1097.28 | 1992.38 | 952.97 | 0.00 | 0.00 | 0.00 |
May | 1582.79 | 324.05 | 1258.74 | 1838.35 | 572.49 | 0.00 | 0.00 | 0.00 |
June | 1494.54 | 230.28 | 1264.27 | 1992.65 | 283.86 | 0.00 | 0.00 | 0.00 |
July | 1555.08 | 262.47 | 1292.62 | 2281.11 | 128.38 | 0.00 | 0.00 | 0.00 |
August | 2082.88 | 768.36 | 1314.52 | 3034.84 | 204.25 | 0.00 | 0.00 | 0.00 |
September | 2198.00 | 1103.59 | 1094.42 | 2864.23 | 442.71 | 0.00 | 0.00 | 0.00 |
October | 3106.15 | 1947.82 | 1158.33 | 3746.46 | 872.22 | 0.00 | 0.00 | 0.00 |
November | 2150.80 | 1290.21 | 860.60 | 2221.95 | 1309.40 | 0.00 | 0.00 | 0.00 |
December | 2133.29 | 1515.17 | 618.12 | 2122.91 | 1658.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2084.94 | 1037.67 | 1047.27 | 2410.39 | 943.50 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1494.54 | 230.28 | 618.12 | 1838.35 | 128.38 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3106.15 | 1947.82 | 1314.52 | 3746.46 | 1822.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2565.06 | 1683.23 | 881.83 | 2496.08 | 2487.71 | 0.00 | 0.00 | 0.00 |
February | 3394.59 | 2256.14 | 1138.45 | 3372.45 | 2449.35 | 0.00 | 0.00 | 0.00 |
March | 3007.61 | 1655.65 | 1351.96 | 3157.90 | 1805.36 | 0.00 | 0.00 | 0.00 |
April | 2393.98 | 968.55 | 1425.43 | 2633.62 | 1308.44 | 0.00 | 0.00 | 0.00 |
May | 2056.14 | 420.96 | 1635.17 | 2426.84 | 788.81 | 0.00 | 0.00 | 0.00 |
June | 1941.50 | 299.14 | 1642.35 | 2639.55 | 382.51 | 0.00 | 0.00 | 0.00 |
July | 2020.14 | 340.96 | 1679.18 | 3031.05 | 168.59 | 0.00 | 0.00 | 0.00 |
August | 2705.78 | 998.14 | 1707.64 | 4030.56 | 263.05 | 0.00 | 0.00 | 0.00 |
September | 2855.33 | 1433.62 | 1421.71 | 3788.10 | 592.08 | 0.00 | 0.00 | 0.00 |
October | 4035.07 | 2530.33 | 1504.74 | 4957.12 | 1160.34 | 0.00 | 0.00 | 0.00 |
November | 2794.02 | 1676.05 | 1117.96 | 2929.67 | 1793.22 | 0.00 | 0.00 | 0.00 |
December | 2771.26 | 1968.29 | 802.97 | 2800.32 | 2267.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2708.45 | 1347.99 | 1360.46 | 3189.19 | 1282.33 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1941.50 | 299.14 | 802.97 | 2426.84 | 168.59 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4035.07 | 2530.33 | 1707.64 | 4957.12 | 2487.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 138.64 | 90.98 | 47.66 | 135.49 | 125.55 | 0.00 | 0.00 | 0.00 |
February | 183.48 | 121.94 | 61.53 | 182.58 | 124.54 | 0.00 | 0.00 | 0.00 |
March | 162.56 | 89.49 | 73.07 | 170.31 | 88.61 | 0.00 | 0.00 | 0.00 |
April | 129.39 | 52.35 | 77.04 | 142.51 | 62.04 | 0.00 | 0.00 | 0.00 |
May | 111.13 | 22.75 | 88.38 | 131.85 | 34.78 | 0.00 | 0.00 | 0.00 |
June | 104.94 | 16.17 | 88.77 | 144.94 | 13.39 | 0.00 | 0.00 | 0.00 |
July | 109.19 | 18.43 | 90.76 | 168.95 | 3.40 | 0.00 | 0.00 | 0.00 |
August | 146.25 | 53.95 | 92.30 | 222.58 | 8.03 | 0.00 | 0.00 | 0.00 |
September | 154.33 | 77.49 | 76.84 | 207.05 | 22.66 | 0.00 | 0.00 | 0.00 |
October | 218.09 | 136.76 | 81.33 | 268.58 | 52.30 | 0.00 | 0.00 | 0.00 |
November | 151.02 | 90.59 | 60.43 | 160.46 | 85.77 | 0.00 | 0.00 | 0.00 |
December | 149.79 | 106.39 | 43.40 | 152.75 | 111.92 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.39 | 72.86 | 73.53 | 174.05 | 60.73 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 104.94 | 16.17 | 43.40 | 131.85 | 3.40 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 218.09 | 136.76 | 92.30 | 268.58 | 125.55 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.04 | 42.30 | 60.74 | 62.30 | 252.44 | 0.00 | 0.00 | 0.00 |
February | 151.36 | 66.43 | 84.93 | 101.89 | 254.84 | 0.00 | 0.00 | 0.00 |
March | 224.83 | 104.19 | 120.64 | 199.40 | 164.88 | 0.00 | 0.00 | 0.00 |
April | 244.19 | 104.35 | 139.83 | 250.16 | 113.19 | 0.00 | 0.00 | 0.00 |
May | 285.26 | 108.44 | 176.82 | 335.10 | 63.07 | 0.00 | 0.00 | 0.00 |
June | 311.67 | 125.78 | 185.89 | 414.02 | 24.48 | 0.00 | 0.00 | 0.00 |
July | 291.59 | 109.58 | 182.02 | 421.27 | 6.27 | 0.00 | 0.00 | 0.00 |
August | 322.62 | 149.16 | 173.45 | 460.27 | 14.88 | 0.00 | 0.00 | 0.00 |
September | 229.53 | 100.21 | 129.33 | 292.10 | 42.38 | 0.00 | 0.00 | 0.00 |
October | 227.75 | 110.94 | 116.80 | 254.63 | 100.33 | 0.00 | 0.00 | 0.00 |
November | 107.25 | 31.33 | 75.92 | 73.58 | 169.67 | 0.00 | 0.00 | 0.00 |
December | 94.74 | 40.89 | 53.84 | 58.57 | 228.61 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 216.61 | 91.35 | 125.26 | 244.62 | 118.83 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.74 | 31.33 | 53.84 | 58.57 | 6.27 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 322.62 | 149.16 | 185.89 | 460.27 | 254.84 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.67 | 0.00 | 26.67 | 2.23 | 139.87 | 0.00 | 0.00 | 0.00 |
February | 36.50 | 0.00 | 36.50 | 4.36 | 142.77 | 0.00 | 0.00 | 0.00 |
March | 50.63 | 0.00 | 50.63 | 20.12 | 92.25 | 0.00 | 0.00 | 0.00 |
April | 60.93 | 0.25 | 60.68 | 41.73 | 60.97 | 0.00 | 0.00 | 0.00 |
May | 81.04 | 2.97 | 78.07 | 81.73 | 32.37 | 0.00 | 0.00 | 0.00 |
June | 85.49 | 4.55 | 80.95 | 111.30 | 12.64 | 0.00 | 0.00 | 0.00 |
July | 82.98 | 3.24 | 79.74 | 125.83 | 3.30 | 0.00 | 0.00 | 0.00 |
August | 73.38 | 0.98 | 72.41 | 110.32 | 7.63 | 0.00 | 0.00 | 0.00 |
September | 55.25 | 0.03 | 55.22 | 64.42 | 22.35 | 0.00 | 0.00 | 0.00 |
October | 47.78 | 0.00 | 47.78 | 38.71 | 53.54 | 0.00 | 0.00 | 0.00 |
November | 33.51 | 0.00 | 33.51 | 11.57 | 91.93 | 0.00 | 0.00 | 0.00 |
December | 23.27 | 0.00 | 23.27 | 1.56 | 126.01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 54.89 | 1.01 | 53.89 | 51.47 | 65.04 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.27 | 0.00 | 23.27 | 1.56 | 3.30 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 85.49 | 4.55 | 80.95 | 125.83 | 142.77 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.04 | 42.30 | 60.74 | 65.34 | 249.92 | 0.00 | 0.00 | 0.00 |
February | 151.36 | 66.43 | 84.93 | 106.52 | 251.05 | 0.00 | 0.00 | 0.00 |
March | 224.83 | 104.19 | 120.64 | 204.56 | 162.46 | 0.00 | 0.00 | 0.00 |
April | 244.19 | 104.35 | 139.83 | 253.44 | 112.06 | 0.00 | 0.00 | 0.00 |
May | 285.26 | 108.44 | 176.82 | 336.52 | 62.73 | 0.00 | 0.00 | 0.00 |
June | 311.67 | 125.78 | 185.89 | 414.81 | 24.30 | 0.00 | 0.00 | 0.00 |
July | 291.59 | 109.58 | 182.02 | 422.21 | 6.16 | 0.00 | 0.00 | 0.00 |
August | 322.62 | 149.16 | 173.45 | 462.57 | 14.46 | 0.00 | 0.00 | 0.00 |
September | 229.53 | 100.21 | 129.33 | 295.29 | 41.34 | 0.00 | 0.00 | 0.00 |
October | 227.75 | 110.94 | 116.80 | 260.27 | 97.80 | 0.00 | 0.00 | 0.00 |
November | 107.25 | 31.33 | 75.92 | 77.81 | 166.80 | 0.00 | 0.00 | 0.00 |
December | 94.74 | 40.89 | 53.84 | 62.17 | 225.40 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 216.61 | 91.35 | 125.26 | 247.80 | 117.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.74 | 31.33 | 53.84 | 62.17 | 6.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 322.62 | 149.16 | 185.89 | 462.57 | 251.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 110.89 | 72.77 | 38.12 | 107.99 | 97.62 | 0.00 | 0.00 | 0.00 |
February | 146.75 | 97.54 | 49.22 | 144.36 | 100.62 | 0.00 | 0.00 | 0.00 |
March | 130.02 | 71.58 | 58.45 | 135.04 | 73.71 | 0.00 | 0.00 | 0.00 |
April | 103.50 | 41.87 | 61.62 | 112.77 | 52.83 | 0.00 | 0.00 | 0.00 |
May | 88.89 | 18.20 | 70.69 | 103.50 | 32.23 | 0.00 | 0.00 | 0.00 |
June | 83.93 | 12.93 | 71.00 | 114.17 | 14.53 | 0.00 | 0.00 | 0.00 |
July | 87.33 | 14.74 | 72.59 | 132.30 | 5.44 | 0.00 | 0.00 | 0.00 |
August | 116.97 | 43.15 | 73.82 | 175.56 | 9.45 | 0.00 | 0.00 | 0.00 |
September | 123.44 | 61.98 | 61.46 | 163.16 | 23.54 | 0.00 | 0.00 | 0.00 |
October | 174.44 | 109.39 | 65.05 | 211.81 | 49.24 | 0.00 | 0.00 | 0.00 |
November | 120.79 | 72.46 | 48.33 | 125.74 | 72.78 | 0.00 | 0.00 | 0.00 |
December | 119.81 | 85.09 | 34.71 | 120.68 | 89.93 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 117.09 | 58.28 | 58.81 | 137.29 | 51.55 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 83.93 | 12.93 | 34.71 | 103.50 | 5.44 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 174.44 | 109.39 | 73.82 | 211.81 | 100.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.34 | 0.00 | 21.34 | 1.41 | 116.81 | 0.00 | 0.00 | 0.00 |
February | 29.20 | 0.00 | 29.20 | 3.15 | 118.05 | 0.00 | 0.00 | 0.00 |
March | 40.51 | 0.00 | 40.51 | 16.20 | 75.12 | 0.00 | 0.00 | 0.00 |
April | 48.75 | 0.20 | 48.55 | 34.67 | 49.10 | 0.00 | 0.00 | 0.00 |
May | 64.84 | 2.37 | 62.47 | 68.59 | 25.23 | 0.00 | 0.00 | 0.00 |
June | 68.40 | 3.64 | 64.76 | 93.94 | 8.77 | 0.00 | 0.00 | 0.00 |
July | 66.39 | 2.59 | 63.80 | 106.14 | 1.80 | 0.00 | 0.00 | 0.00 |
August | 58.71 | 0.78 | 57.93 | 94.15 | 4.89 | 0.00 | 0.00 | 0.00 |
September | 44.21 | 0.03 | 44.18 | 55.13 | 16.44 | 0.00 | 0.00 | 0.00 |
October | 38.23 | 0.00 | 38.23 | 33.02 | 41.78 | 0.00 | 0.00 | 0.00 |
November | 26.81 | 0.00 | 26.81 | 8.92 | 76.61 | 0.00 | 0.00 | 0.00 |
December | 18.62 | 0.00 | 18.62 | 0.98 | 105.54 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 43.92 | 0.81 | 43.11 | 43.30 | 52.98 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.62 | 0.00 | 18.62 | 0.98 | 1.80 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 68.40 | 3.64 | 64.76 | 106.14 | 118.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.76 | 41.46 | 62.31 | 61.21 | 248.22 | 0.00 | 0.00 | 0.00 |
February | 161.10 | 75.02 | 86.08 | 108.85 | 245.76 | 0.00 | 0.00 | 0.00 |
March | 206.88 | 87.92 | 118.96 | 177.65 | 165.46 | 0.00 | 0.00 | 0.00 |
April | 247.65 | 108.70 | 138.95 | 251.93 | 109.87 | 0.00 | 0.00 | 0.00 |
May | 298.99 | 119.15 | 179.84 | 351.91 | 61.14 | 0.00 | 0.00 | 0.00 |
June | 277.63 | 100.56 | 177.07 | 369.21 | 23.36 | 0.00 | 0.00 | 0.00 |
July | 278.48 | 100.26 | 178.22 | 404.93 | 5.93 | 0.00 | 0.00 | 0.00 |
August | 314.15 | 141.73 | 172.42 | 448.64 | 13.95 | 0.00 | 0.00 | 0.00 |
September | 235.00 | 105.87 | 129.14 | 298.24 | 40.71 | 0.00 | 0.00 | 0.00 |
October | 212.30 | 96.10 | 116.20 | 233.72 | 97.73 | 0.00 | 0.00 | 0.00 |
November | 131.49 | 50.53 | 80.96 | 103.84 | 165.61 | 0.00 | 0.00 | 0.00 |
December | 102.80 | 48.51 | 54.30 | 66.90 | 223.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 214.53 | 89.75 | 124.78 | 240.65 | 116.02 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 102.80 | 41.46 | 54.30 | 61.21 | 5.93 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 314.15 | 141.73 | 179.84 | 448.64 | 248.22 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 138.64 | 90.98 | 47.66 | 135.21 | 125.36 | 0.00 | 0.00 | 0.00 |
February | 183.48 | 121.94 | 61.53 | 181.86 | 124.21 | 0.00 | 0.00 | 0.00 |
March | 162.56 | 89.49 | 73.07 | 169.38 | 87.74 | 0.00 | 0.00 | 0.00 |
April | 129.39 | 52.35 | 77.04 | 141.36 | 61.55 | 0.00 | 0.00 | 0.00 |
May | 111.13 | 22.75 | 88.38 | 130.76 | 34.30 | 0.00 | 0.00 | 0.00 |
June | 104.94 | 16.17 | 88.77 | 144.92 | 12.92 | 0.00 | 0.00 | 0.00 |
July | 109.19 | 18.43 | 90.76 | 168.85 | 3.20 | 0.00 | 0.00 | 0.00 |
August | 146.25 | 53.95 | 92.30 | 222.29 | 7.72 | 0.00 | 0.00 | 0.00 |
September | 154.33 | 77.49 | 76.84 | 206.47 | 22.33 | 0.00 | 0.00 | 0.00 |
October | 218.09 | 136.76 | 81.33 | 267.95 | 51.75 | 0.00 | 0.00 | 0.00 |
November | 151.02 | 90.59 | 60.43 | 159.61 | 85.88 | 0.00 | 0.00 | 0.00 |
December | 149.79 | 106.39 | 43.40 | 152.33 | 111.77 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.39 | 72.86 | 73.53 | 173.46 | 60.37 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 104.94 | 16.17 | 43.40 | 130.76 | 3.20 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 218.09 | 136.76 | 92.30 | 267.95 | 125.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.67 | 0.00 | 26.67 | 2.05 | 139.83 | 0.00 | 0.00 | 0.00 |
February | 36.50 | 0.00 | 36.50 | 4.09 | 142.70 | 0.00 | 0.00 | 0.00 |
March | 50.63 | 0.00 | 50.63 | 19.27 | 91.41 | 0.00 | 0.00 | 0.00 |
April | 60.93 | 0.25 | 60.68 | 40.50 | 60.64 | 0.00 | 0.00 | 0.00 |
May | 81.04 | 2.97 | 78.07 | 80.57 | 32.02 | 0.00 | 0.00 | 0.00 |
June | 85.49 | 4.55 | 80.95 | 111.28 | 12.23 | 0.00 | 0.00 | 0.00 |
July | 82.98 | 3.24 | 79.74 | 125.71 | 3.11 | 0.00 | 0.00 | 0.00 |
August | 73.38 | 0.98 | 72.41 | 109.92 | 7.33 | 0.00 | 0.00 | 0.00 |
September | 55.25 | 0.03 | 55.22 | 63.60 | 22.06 | 0.00 | 0.00 | 0.00 |
October | 47.78 | 0.00 | 47.78 | 37.73 | 52.84 | 0.00 | 0.00 | 0.00 |
November | 33.51 | 0.00 | 33.51 | 10.94 | 92.14 | 0.00 | 0.00 | 0.00 |
December | 23.27 | 0.00 | 23.27 | 1.37 | 125.95 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 54.89 | 1.01 | 53.89 | 50.90 | 64.75 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.27 | 0.00 | 23.27 | 1.37 | 3.11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 85.49 | 4.55 | 80.95 | 125.71 | 142.70 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.76 | 41.46 | 62.31 | 63.21 | 244.71 | 0.00 | 0.00 | 0.00 |
February | 161.10 | 75.02 | 86.08 | 112.21 | 240.48 | 0.00 | 0.00 | 0.00 |
March | 206.88 | 87.92 | 118.96 | 182.34 | 162.42 | 0.00 | 0.00 | 0.00 |
April | 247.65 | 108.70 | 138.95 | 254.76 | 108.63 | 0.00 | 0.00 | 0.00 |
May | 298.99 | 119.15 | 179.84 | 353.06 | 60.79 | 0.00 | 0.00 | 0.00 |
June | 277.63 | 100.56 | 177.07 | 369.97 | 23.19 | 0.00 | 0.00 | 0.00 |
July | 278.48 | 100.26 | 178.22 | 405.87 | 5.82 | 0.00 | 0.00 | 0.00 |
August | 314.15 | 141.73 | 172.42 | 450.82 | 13.55 | 0.00 | 0.00 | 0.00 |
September | 235.00 | 105.87 | 129.14 | 301.03 | 39.65 | 0.00 | 0.00 | 0.00 |
October | 212.30 | 96.10 | 116.20 | 238.84 | 94.87 | 0.00 | 0.00 | 0.00 |
November | 131.49 | 50.53 | 80.96 | 107.51 | 162.12 | 0.00 | 0.00 | 0.00 |
December | 102.80 | 48.51 | 54.30 | 69.12 | 218.26 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 214.53 | 89.75 | 124.78 | 243.29 | 113.85 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 102.80 | 41.46 | 54.30 | 63.21 | 5.82 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 314.15 | 141.73 | 179.84 | 450.82 | 244.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.78 | 0.00 | 33.78 | 1.66 | 191.93 | 0.00 | 0.00 | 0.00 |
February | 46.23 | 0.00 | 46.23 | 4.13 | 194.41 | 0.00 | 0.00 | 0.00 |
March | 64.12 | 0.00 | 64.12 | 23.86 | 123.81 | 0.00 | 0.00 | 0.00 |
April | 77.16 | 0.32 | 76.84 | 52.56 | 83.08 | 0.00 | 0.00 | 0.00 |
May | 102.63 | 3.76 | 98.87 | 103.70 | 46.12 | 0.00 | 0.00 | 0.00 |
June | 108.27 | 5.76 | 102.51 | 138.90 | 22.13 | 0.00 | 0.00 | 0.00 |
July | 105.09 | 4.10 | 100.99 | 154.27 | 9.15 | 0.00 | 0.00 | 0.00 |
August | 92.93 | 1.23 | 91.70 | 134.37 | 15.40 | 0.00 | 0.00 | 0.00 |
September | 69.98 | 0.04 | 69.94 | 78.71 | 36.74 | 0.00 | 0.00 | 0.00 |
October | 60.51 | 0.00 | 60.51 | 46.48 | 77.86 | 0.00 | 0.00 | 0.00 |
November | 42.44 | 0.00 | 42.44 | 12.51 | 127.65 | 0.00 | 0.00 | 0.00 |
December | 29.46 | 0.00 | 29.46 | 1.13 | 173.98 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 69.52 | 1.28 | 68.24 | 63.08 | 91.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 29.46 | 0.00 | 29.46 | 1.13 | 9.15 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 108.27 | 5.76 | 102.51 | 154.27 | 194.41 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 12.45 | 0.00 | 12.45 | 0.61 | 70.75 | 0.00 | 0.00 | 0.00 |
February | 17.04 | 0.00 | 17.04 | 1.52 | 71.67 | 0.00 | 0.00 | 0.00 |
March | 23.64 | 0.00 | 23.64 | 8.80 | 45.64 | 0.00 | 0.00 | 0.00 |
April | 28.45 | 0.12 | 28.33 | 19.37 | 30.63 | 0.00 | 0.00 | 0.00 |
May | 37.83 | 1.38 | 36.45 | 38.23 | 17.00 | 0.00 | 0.00 | 0.00 |
June | 39.91 | 2.12 | 37.79 | 51.21 | 8.16 | 0.00 | 0.00 | 0.00 |
July | 38.74 | 1.51 | 37.23 | 56.87 | 3.37 | 0.00 | 0.00 | 0.00 |
August | 34.26 | 0.46 | 33.80 | 49.53 | 5.68 | 0.00 | 0.00 | 0.00 |
September | 25.80 | 0.01 | 25.78 | 29.02 | 13.54 | 0.00 | 0.00 | 0.00 |
October | 22.31 | 0.00 | 22.31 | 17.13 | 28.70 | 0.00 | 0.00 | 0.00 |
November | 15.65 | 0.00 | 15.65 | 4.61 | 47.06 | 0.00 | 0.00 | 0.00 |
December | 10.86 | 0.00 | 10.86 | 0.42 | 64.14 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 25.63 | 0.47 | 25.16 | 23.26 | 33.65 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 10.86 | 0.00 | 10.86 | 0.42 | 3.37 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 39.91 | 2.12 | 37.79 | 56.87 | 71.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.69 | 42.45 | 22.24 | 62.74 | 62.16 | 0.00 | 0.00 | 0.00 |
February | 85.61 | 56.90 | 28.71 | 84.95 | 60.98 | 0.00 | 0.00 | 0.00 |
March | 75.85 | 41.75 | 34.10 | 80.01 | 43.14 | 0.00 | 0.00 | 0.00 |
April | 60.37 | 24.43 | 35.95 | 67.05 | 30.73 | 0.00 | 0.00 | 0.00 |
May | 51.85 | 10.62 | 41.24 | 61.98 | 18.15 | 0.00 | 0.00 | 0.00 |
June | 48.96 | 7.54 | 41.42 | 67.14 | 8.61 | 0.00 | 0.00 | 0.00 |
July | 50.95 | 8.60 | 42.35 | 77.17 | 3.44 | 0.00 | 0.00 | 0.00 |
August | 68.24 | 25.17 | 43.07 | 102.41 | 5.84 | 0.00 | 0.00 | 0.00 |
September | 72.01 | 36.16 | 35.85 | 96.20 | 13.40 | 0.00 | 0.00 | 0.00 |
October | 101.76 | 63.81 | 37.95 | 125.69 | 27.25 | 0.00 | 0.00 | 0.00 |
November | 70.46 | 42.27 | 28.19 | 74.61 | 42.68 | 0.00 | 0.00 | 0.00 |
December | 69.89 | 49.64 | 20.25 | 71.00 | 55.35 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 68.31 | 34.00 | 34.31 | 80.93 | 30.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 48.96 | 7.54 | 20.25 | 61.98 | 3.44 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 101.76 | 63.81 | 43.07 | 125.69 | 62.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 175.58 | 115.22 | 60.36 | 170.28 | 168.73 | 0.00 | 0.00 | 0.00 |
February | 232.36 | 154.43 | 77.93 | 230.58 | 165.53 | 0.00 | 0.00 | 0.00 |
March | 205.87 | 113.33 | 92.54 | 217.15 | 117.09 | 0.00 | 0.00 | 0.00 |
April | 163.87 | 66.30 | 97.57 | 181.99 | 83.40 | 0.00 | 0.00 | 0.00 |
May | 140.74 | 28.82 | 111.93 | 168.22 | 49.26 | 0.00 | 0.00 | 0.00 |
June | 132.90 | 20.48 | 112.42 | 182.24 | 23.37 | 0.00 | 0.00 | 0.00 |
July | 138.28 | 23.34 | 114.94 | 209.45 | 9.35 | 0.00 | 0.00 | 0.00 |
August | 185.21 | 68.32 | 116.89 | 277.97 | 15.84 | 0.00 | 0.00 | 0.00 |
September | 195.45 | 98.13 | 97.32 | 261.11 | 36.36 | 0.00 | 0.00 | 0.00 |
October | 276.20 | 173.20 | 103.00 | 341.14 | 73.97 | 0.00 | 0.00 | 0.00 |
November | 191.25 | 114.73 | 76.53 | 202.52 | 115.85 | 0.00 | 0.00 | 0.00 |
December | 189.69 | 134.73 | 54.96 | 192.72 | 150.24 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 185.40 | 92.27 | 93.13 | 219.66 | 83.62 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 132.90 | 20.48 | 54.96 | 168.22 | 9.35 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 276.20 | 173.20 | 116.89 | 341.14 | 168.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 138.64 | 90.98 | 47.66 | 135.13 | 124.85 | 0.00 | 0.00 | 0.00 |
February | 183.48 | 121.94 | 61.53 | 181.98 | 123.98 | 0.00 | 0.00 | 0.00 |
March | 162.56 | 89.49 | 73.07 | 169.39 | 88.19 | 0.00 | 0.00 | 0.00 |
April | 129.39 | 52.35 | 77.04 | 141.55 | 61.56 | 0.00 | 0.00 | 0.00 |
May | 111.13 | 22.75 | 88.38 | 130.66 | 34.42 | 0.00 | 0.00 | 0.00 |
June | 104.94 | 16.17 | 88.77 | 143.84 | 12.98 | 0.00 | 0.00 | 0.00 |
July | 109.19 | 18.43 | 90.76 | 168.01 | 3.11 | 0.00 | 0.00 | 0.00 |
August | 146.25 | 53.95 | 92.30 | 221.48 | 7.60 | 0.00 | 0.00 | 0.00 |
September | 154.33 | 77.49 | 76.84 | 205.98 | 21.99 | 0.00 | 0.00 | 0.00 |
October | 218.09 | 136.76 | 81.33 | 267.37 | 51.39 | 0.00 | 0.00 | 0.00 |
November | 151.02 | 90.59 | 60.43 | 160.19 | 84.75 | 0.00 | 0.00 | 0.00 |
December | 149.79 | 106.39 | 43.40 | 152.49 | 111.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.39 | 72.86 | 73.53 | 173.21 | 60.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 104.94 | 16.17 | 43.40 | 130.66 | 3.11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 218.09 | 136.76 | 92.30 | 267.37 | 124.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.04 | 42.30 | 60.74 | 62.21 | 251.19 | 0.00 | 0.00 | 0.00 |
February | 151.36 | 66.43 | 84.93 | 101.30 | 254.02 | 0.00 | 0.00 | 0.00 |
March | 224.83 | 104.19 | 120.64 | 198.10 | 163.84 | 0.00 | 0.00 | 0.00 |
April | 244.19 | 104.35 | 139.83 | 248.54 | 112.08 | 0.00 | 0.00 | 0.00 |
May | 285.26 | 108.44 | 176.82 | 332.70 | 62.24 | 0.00 | 0.00 | 0.00 |
June | 311.67 | 125.78 | 185.89 | 411.35 | 23.65 | 0.00 | 0.00 | 0.00 |
July | 291.59 | 109.58 | 182.02 | 419.15 | 5.73 | 0.00 | 0.00 | 0.00 |
August | 322.62 | 149.16 | 173.45 | 458.35 | 14.06 | 0.00 | 0.00 | 0.00 |
September | 229.53 | 100.21 | 129.33 | 290.67 | 41.08 | 0.00 | 0.00 | 0.00 |
October | 227.75 | 110.94 | 116.80 | 253.36 | 98.49 | 0.00 | 0.00 | 0.00 |
November | 107.25 | 31.33 | 75.92 | 73.67 | 167.70 | 0.00 | 0.00 | 0.00 |
December | 94.74 | 40.89 | 53.84 | 58.56 | 226.86 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 216.61 | 91.35 | 125.26 | 243.34 | 117.65 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.74 | 31.33 | 53.84 | 58.56 | 5.73 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 322.62 | 149.16 | 185.89 | 458.35 | 254.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.67 | 0.00 | 26.67 | 2.31 | 139.19 | 0.00 | 0.00 | 0.00 |
February | 36.50 | 0.00 | 36.50 | 4.45 | 142.39 | 0.00 | 0.00 | 0.00 |
March | 50.63 | 0.00 | 50.63 | 20.21 | 91.74 | 0.00 | 0.00 | 0.00 |
April | 60.93 | 0.25 | 60.68 | 41.65 | 60.37 | 0.00 | 0.00 | 0.00 |
May | 81.04 | 2.97 | 78.07 | 80.97 | 32.00 | 0.00 | 0.00 | 0.00 |
June | 85.49 | 4.55 | 80.95 | 110.59 | 12.24 | 0.00 | 0.00 | 0.00 |
July | 82.98 | 3.24 | 79.74 | 125.25 | 3.05 | 0.00 | 0.00 | 0.00 |
August | 73.38 | 0.98 | 72.41 | 110.03 | 7.21 | 0.00 | 0.00 | 0.00 |
September | 55.25 | 0.03 | 55.22 | 64.27 | 21.64 | 0.00 | 0.00 | 0.00 |
October | 47.78 | 0.00 | 47.78 | 39.04 | 52.37 | 0.00 | 0.00 | 0.00 |
November | 33.51 | 0.00 | 33.51 | 11.91 | 90.66 | 0.00 | 0.00 | 0.00 |
December | 23.27 | 0.00 | 23.27 | 1.67 | 124.92 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 54.89 | 1.01 | 53.89 | 51.34 | 64.38 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.27 | 0.00 | 23.27 | 1.67 | 3.05 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 85.49 | 4.55 | 80.95 | 125.25 | 142.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.04 | 42.30 | 60.74 | 65.23 | 248.81 | 0.00 | 0.00 | 0.00 |
February | 151.36 | 66.43 | 84.93 | 106.03 | 250.37 | 0.00 | 0.00 | 0.00 |
March | 224.83 | 104.19 | 120.64 | 203.65 | 161.31 | 0.00 | 0.00 | 0.00 |
April | 244.19 | 104.35 | 139.83 | 252.08 | 110.87 | 0.00 | 0.00 | 0.00 |
May | 285.26 | 108.44 | 176.82 | 334.15 | 61.88 | 0.00 | 0.00 | 0.00 |
June | 311.67 | 125.78 | 185.89 | 412.15 | 23.48 | 0.00 | 0.00 | 0.00 |
July | 291.59 | 109.58 | 182.02 | 420.13 | 5.62 | 0.00 | 0.00 | 0.00 |
August | 322.62 | 149.16 | 173.45 | 460.76 | 13.62 | 0.00 | 0.00 | 0.00 |
September | 229.53 | 100.21 | 129.33 | 294.09 | 39.92 | 0.00 | 0.00 | 0.00 |
October | 227.75 | 110.94 | 116.80 | 259.74 | 95.54 | 0.00 | 0.00 | 0.00 |
November | 107.25 | 31.33 | 75.92 | 78.22 | 164.71 | 0.00 | 0.00 | 0.00 |
December | 94.74 | 40.89 | 53.84 | 62.31 | 223.77 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 216.61 | 91.35 | 125.26 | 246.71 | 115.91 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.74 | 31.33 | 53.84 | 62.31 | 5.62 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 322.62 | 149.16 | 185.89 | 460.76 | 250.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 203.33 | 133.43 | 69.90 | 192.02 | 190.09 | 0.00 | 0.00 | 0.00 |
February | 269.09 | 178.84 | 90.24 | 258.94 | 189.12 | 0.00 | 0.00 | 0.00 |
March | 238.41 | 131.24 | 107.17 | 243.99 | 132.95 | 0.00 | 0.00 | 0.00 |
April | 189.77 | 76.78 | 112.99 | 205.69 | 91.38 | 0.00 | 0.00 | 0.00 |
May | 162.99 | 33.37 | 129.62 | 192.84 | 49.74 | 0.00 | 0.00 | 0.00 |
June | 153.90 | 23.71 | 130.19 | 214.50 | 17.71 | 0.00 | 0.00 | 0.00 |
July | 160.14 | 27.03 | 133.11 | 250.38 | 3.82 | 0.00 | 0.00 | 0.00 |
August | 214.49 | 79.12 | 135.36 | 328.05 | 10.27 | 0.00 | 0.00 | 0.00 |
September | 226.34 | 113.64 | 112.70 | 301.81 | 32.18 | 0.00 | 0.00 | 0.00 |
October | 319.86 | 200.58 | 119.28 | 388.68 | 77.40 | 0.00 | 0.00 | 0.00 |
November | 221.48 | 132.86 | 88.62 | 228.58 | 130.87 | 0.00 | 0.00 | 0.00 |
December | 219.68 | 156.02 | 63.65 | 216.95 | 170.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 214.70 | 106.85 | 107.84 | 251.97 | 90.76 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 153.90 | 23.71 | 63.65 | 192.02 | 3.82 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 319.86 | 200.58 | 135.36 | 388.68 | 190.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 186.70 | 0.00 | 186.70 | 4.17 | 1177.81 | 0.00 | 0.00 | 0.00 |
February | 255.50 | 0.00 | 255.50 | 14.31 | 1187.26 | 0.00 | 0.00 | 0.00 |
March | 354.39 | 0.01 | 354.39 | 103.09 | 790.65 | 0.00 | 0.00 | 0.00 |
April | 426.48 | 1.76 | 424.73 | 247.09 | 535.30 | 0.00 | 0.00 | 0.00 |
May | 567.24 | 20.76 | 546.48 | 516.90 | 292.65 | 0.00 | 0.00 | 0.00 |
June | 598.43 | 31.83 | 566.60 | 732.39 | 138.24 | 0.00 | 0.00 | 0.00 |
July | 580.84 | 22.67 | 558.17 | 828.77 | 58.71 | 0.00 | 0.00 | 0.00 |
August | 513.65 | 6.82 | 506.83 | 726.66 | 89.70 | 0.00 | 0.00 | 0.00 |
September | 386.77 | 0.22 | 386.54 | 411.55 | 226.48 | 0.00 | 0.00 | 0.00 |
October | 334.44 | 0.00 | 334.44 | 235.00 | 468.51 | 0.00 | 0.00 | 0.00 |
November | 234.58 | 0.00 | 234.58 | 52.01 | 811.03 | 0.00 | 0.00 | 0.00 |
December | 162.86 | 0.00 | 162.86 | 2.97 | 1087.28 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 384.23 | 7.05 | 377.19 | 325.03 | 568.49 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 162.86 | 0.00 | 162.86 | 2.97 | 58.71 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 598.43 | 31.83 | 566.60 | 828.77 | 1187.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 186.70 | 0.00 | 186.70 | 2.83 | 1212.98 | 0.00 | 0.00 | 0.00 |
February | 255.50 | 0.00 | 255.50 | 12.06 | 1220.76 | 0.00 | 0.00 | 0.00 |
March | 354.39 | 0.01 | 354.39 | 95.36 | 813.89 | 0.00 | 0.00 | 0.00 |
April | 426.48 | 1.76 | 424.73 | 236.39 | 551.55 | 0.00 | 0.00 | 0.00 |
May | 567.24 | 20.76 | 546.48 | 505.08 | 300.96 | 0.00 | 0.00 | 0.00 |
June | 598.43 | 31.83 | 566.60 | 723.60 | 143.67 | 0.00 | 0.00 | 0.00 |
July | 580.84 | 22.67 | 558.17 | 821.04 | 62.77 | 0.00 | 0.00 | 0.00 |
August | 513.65 | 6.82 | 506.83 | 718.70 | 93.95 | 0.00 | 0.00 | 0.00 |
September | 386.77 | 0.22 | 386.54 | 403.51 | 234.72 | 0.00 | 0.00 | 0.00 |
October | 334.44 | 0.00 | 334.44 | 226.51 | 481.41 | 0.00 | 0.00 | 0.00 |
November | 234.58 | 0.00 | 234.58 | 47.12 | 837.28 | 0.00 | 0.00 | 0.00 |
December | 162.86 | 0.00 | 162.86 | 2.17 | 1120.23 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 384.23 | 7.05 | 377.19 | 318.30 | 585.95 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 162.86 | 0.00 | 162.86 | 2.17 | 62.77 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 598.43 | 31.83 | 566.60 | 821.04 | 1220.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.67 | 0.00 | 26.67 | 2.37 | 150.22 | 0.00 | 0.00 | 0.00 |
February | 36.50 | 0.00 | 36.50 | 4.37 | 152.27 | 0.00 | 0.00 | 0.00 |
March | 50.63 | 0.00 | 50.63 | 21.60 | 99.90 | 0.00 | 0.00 | 0.00 |
April | 60.93 | 0.25 | 60.68 | 49.08 | 68.20 | 0.00 | 0.00 | 0.00 |
May | 81.04 | 2.97 | 78.07 | 96.20 | 38.78 | 0.00 | 0.00 | 0.00 |
June | 85.49 | 4.55 | 80.95 | 131.08 | 18.64 | 0.00 | 0.00 | 0.00 |
July | 82.98 | 3.24 | 79.74 | 147.45 | 8.36 | 0.00 | 0.00 | 0.00 |
August | 73.38 | 0.98 | 72.41 | 130.89 | 12.05 | 0.00 | 0.00 | 0.00 |
September | 55.25 | 0.03 | 55.22 | 80.32 | 27.22 | 0.00 | 0.00 | 0.00 |
October | 47.78 | 0.00 | 47.78 | 47.20 | 56.80 | 0.00 | 0.00 | 0.00 |
November | 33.51 | 0.00 | 33.51 | 12.85 | 101.01 | 0.00 | 0.00 | 0.00 |
December | 23.27 | 0.00 | 23.27 | 1.66 | 136.25 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 54.89 | 1.01 | 53.89 | 60.80 | 72.02 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.27 | 0.00 | 23.27 | 1.66 | 8.36 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 85.49 | 4.55 | 80.95 | 147.45 | 152.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 207.51 | 82.91 | 124.60 | 129.51 | 527.42 | 0.00 | 0.00 | 0.00 |
February | 322.18 | 150.03 | 172.15 | 228.64 | 513.88 | 0.00 | 0.00 | 0.00 |
March | 413.73 | 175.83 | 237.90 | 377.01 | 358.59 | 0.00 | 0.00 | 0.00 |
April | 495.27 | 217.38 | 277.89 | 543.65 | 246.67 | 0.00 | 0.00 | 0.00 |
May | 597.93 | 238.28 | 359.65 | 762.17 | 145.96 | 0.00 | 0.00 | 0.00 |
June | 555.22 | 201.11 | 354.12 | 812.50 | 70.06 | 0.00 | 0.00 | 0.00 |
July | 556.92 | 200.50 | 356.42 | 891.77 | 31.51 | 0.00 | 0.00 | 0.00 |
August | 628.26 | 283.45 | 344.82 | 979.28 | 45.09 | 0.00 | 0.00 | 0.00 |
September | 469.97 | 211.72 | 258.25 | 665.51 | 100.00 | 0.00 | 0.00 | 0.00 |
October | 424.58 | 192.19 | 232.39 | 518.07 | 206.24 | 0.00 | 0.00 | 0.00 |
November | 262.97 | 101.05 | 161.91 | 226.22 | 354.60 | 0.00 | 0.00 | 0.00 |
December | 205.59 | 97.01 | 108.58 | 142.51 | 472.43 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 429.02 | 179.49 | 249.53 | 525.06 | 254.61 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 205.59 | 82.91 | 108.58 | 129.51 | 31.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 628.26 | 283.45 | 359.65 | 979.28 | 527.42 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 138.64 | 90.98 | 47.66 | 137.96 | 133.58 | 0.00 | 0.00 | 0.00 |
February | 183.48 | 121.94 | 61.53 | 186.30 | 130.52 | 0.00 | 0.00 | 0.00 |
March | 162.56 | 89.49 | 73.07 | 176.57 | 95.17 | 0.00 | 0.00 | 0.00 |
April | 129.39 | 52.35 | 77.04 | 151.88 | 68.45 | 0.00 | 0.00 | 0.00 |
May | 111.13 | 22.75 | 88.38 | 146.66 | 40.50 | 0.00 | 0.00 | 0.00 |
June | 104.94 | 16.17 | 88.77 | 164.41 | 19.42 | 0.00 | 0.00 | 0.00 |
July | 109.19 | 18.43 | 90.76 | 190.46 | 8.54 | 0.00 | 0.00 | 0.00 |
August | 146.25 | 53.95 | 92.30 | 244.37 | 12.16 | 0.00 | 0.00 | 0.00 |
September | 154.33 | 77.49 | 76.84 | 225.10 | 26.99 | 0.00 | 0.00 | 0.00 |
October | 218.09 | 136.76 | 81.33 | 282.50 | 55.31 | 0.00 | 0.00 | 0.00 |
November | 151.02 | 90.59 | 60.43 | 165.53 | 92.44 | 0.00 | 0.00 | 0.00 |
December | 149.79 | 106.39 | 43.40 | 155.89 | 119.26 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.39 | 72.86 | 73.53 | 185.73 | 66.50 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 104.94 | 16.17 | 43.40 | 137.96 | 8.54 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 218.09 | 136.76 | 92.30 | 282.50 | 133.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.78 | 0.00 | 33.78 | 1.28 | 195.51 | 0.00 | 0.00 | 0.00 |
February | 46.23 | 0.00 | 46.23 | 3.46 | 198.32 | 0.00 | 0.00 | 0.00 |
March | 64.12 | 0.00 | 64.12 | 21.64 | 126.43 | 0.00 | 0.00 | 0.00 |
April | 77.16 | 0.32 | 76.84 | 49.66 | 84.42 | 0.00 | 0.00 | 0.00 |
May | 102.63 | 3.76 | 98.87 | 99.50 | 47.33 | 0.00 | 0.00 | 0.00 |
June | 108.27 | 5.76 | 102.51 | 134.19 | 23.58 | 0.00 | 0.00 | 0.00 |
July | 105.09 | 4.10 | 100.99 | 149.47 | 10.60 | 0.00 | 0.00 | 0.00 |
August | 92.93 | 1.23 | 91.70 | 130.45 | 16.27 | 0.00 | 0.00 | 0.00 |
September | 69.98 | 0.04 | 69.94 | 75.73 | 37.73 | 0.00 | 0.00 | 0.00 |
October | 60.51 | 0.00 | 60.51 | 44.53 | 77.31 | 0.00 | 0.00 | 0.00 |
November | 42.44 | 0.00 | 42.44 | 11.47 | 129.59 | 0.00 | 0.00 | 0.00 |
December | 29.46 | 0.00 | 29.46 | 0.87 | 177.74 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 69.52 | 1.28 | 68.24 | 60.57 | 93.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 29.46 | 0.00 | 29.46 | 0.87 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 108.27 | 5.76 | 102.51 | 149.47 | 198.32 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 30.22 | 0.00 | 30.22 | 1.14 | 174.92 | 0.00 | 0.00 | 0.00 |
February | 41.36 | 0.00 | 41.36 | 3.10 | 177.44 | 0.00 | 0.00 | 0.00 |
March | 57.37 | 0.00 | 57.37 | 19.36 | 113.12 | 0.00 | 0.00 | 0.00 |
April | 69.04 | 0.28 | 68.75 | 44.43 | 75.53 | 0.00 | 0.00 | 0.00 |
May | 91.82 | 3.36 | 88.46 | 89.03 | 42.35 | 0.00 | 0.00 | 0.00 |
June | 96.87 | 5.15 | 91.72 | 120.06 | 21.10 | 0.00 | 0.00 | 0.00 |
July | 94.02 | 3.67 | 90.35 | 133.73 | 9.49 | 0.00 | 0.00 | 0.00 |
August | 83.15 | 1.10 | 82.04 | 116.71 | 14.56 | 0.00 | 0.00 | 0.00 |
September | 62.61 | 0.04 | 62.57 | 67.76 | 33.76 | 0.00 | 0.00 | 0.00 |
October | 54.14 | 0.00 | 54.14 | 39.84 | 69.17 | 0.00 | 0.00 | 0.00 |
November | 37.97 | 0.00 | 37.97 | 10.26 | 115.94 | 0.00 | 0.00 | 0.00 |
December | 26.36 | 0.00 | 26.36 | 0.78 | 159.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 62.20 | 1.14 | 61.06 | 54.19 | 83.34 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.36 | 0.00 | 26.36 | 0.78 | 9.49 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 96.87 | 5.15 | 91.72 | 133.73 | 177.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 517.59 | 339.65 | 177.94 | 494.88 | 505.10 | 0.00 | 0.00 | 0.00 |
February | 684.98 | 455.25 | 229.72 | 670.33 | 494.92 | 0.00 | 0.00 | 0.00 |
March | 606.89 | 334.08 | 272.80 | 628.94 | 352.21 | 0.00 | 0.00 | 0.00 |
April | 483.07 | 195.44 | 287.63 | 524.83 | 250.61 | 0.00 | 0.00 | 0.00 |
May | 414.90 | 84.94 | 329.95 | 482.24 | 149.65 | 0.00 | 0.00 | 0.00 |
June | 391.77 | 60.36 | 331.40 | 521.96 | 73.80 | 0.00 | 0.00 | 0.00 |
July | 407.63 | 68.80 | 338.83 | 601.76 | 31.98 | 0.00 | 0.00 | 0.00 |
August | 545.99 | 201.41 | 344.58 | 805.22 | 49.42 | 0.00 | 0.00 | 0.00 |
September | 576.16 | 289.28 | 286.88 | 758.01 | 110.31 | 0.00 | 0.00 | 0.00 |
October | 814.21 | 510.58 | 303.63 | 995.35 | 216.76 | 0.00 | 0.00 | 0.00 |
November | 563.79 | 338.20 | 225.59 | 589.40 | 345.83 | 0.00 | 0.00 | 0.00 |
December | 559.20 | 397.17 | 162.03 | 560.61 | 450.39 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 546.52 | 272.00 | 274.52 | 636.26 | 251.22 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 391.77 | 60.36 | 162.03 | 482.24 | 31.98 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 814.21 | 510.58 | 344.58 | 995.35 | 505.10 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.187811E+10 | 0.123244E+10 | 0.645669E+09 | 0.182023E+10 | 0.168163E+10 |
February | 0.224496E+10 | 0.149206E+10 | 0.752897E+09 | 0.221617E+10 | 0.150288E+10 |
March | 0.220215E+10 | 0.121226E+10 | 0.989890E+09 | 0.230088E+10 | 0.118290E+10 |
April | 0.169631E+10 | 0.686285E+09 | 0.101002E+10 | 0.186783E+10 | 0.806577E+09 |
May | 0.150549E+10 | 0.308226E+09 | 0.119726E+10 | 0.179658E+10 | 0.478379E+09 |
June | 0.137569E+10 | 0.211965E+09 | 0.116373E+10 | 0.186916E+10 | 0.222137E+09 |
July | 0.147913E+10 | 0.249647E+09 | 0.122948E+10 | 0.219781E+10 | 98823119.18 |
August | 0.198115E+10 | 0.730828E+09 | 0.125032E+10 | 0.290961E+10 | 0.174012E+09 |
September | 0.202321E+10 | 0.101583E+10 | 0.100738E+10 | 0.266721E+10 | 0.355119E+09 |
October | 0.295444E+10 | 0.185269E+10 | 0.110176E+10 | 0.359887E+10 | 0.755806E+09 |
November | 0.197976E+10 | 0.118761E+10 | 0.792159E+09 | 0.207865E+10 | 0.113109E+10 |
December | 0.202909E+10 | 0.144117E+10 | 0.587926E+09 | 0.204387E+10 | 0.151246E+10 |
Annual Sum or Average | 0.233495E+11 | 0.116210E+11 | 0.117285E+11 | 0.273669E+11 | 0.990181E+10 |
Minimum of Months | 0.137569E+10 | 0.211965E+09 | 0.587926E+09 | 0.179658E+10 | 98823119.18 |
Maximum of Months | 0.295444E+10 | 0.185269E+10 | 0.125032E+10 | 0.359887E+10 | 0.168163E+10 |
Report: WindowEnergyReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.528864E+10 | 0.347048E+10 | 0.181816E+10 | 0.506423E+10 | 0.488166E+10 |
February | 0.632166E+10 | 0.420155E+10 | 0.212011E+10 | 0.616332E+10 | 0.437443E+10 |
March | 0.620110E+10 | 0.341363E+10 | 0.278747E+10 | 0.639130E+10 | 0.354960E+10 |
April | 0.477669E+10 | 0.193253E+10 | 0.284415E+10 | 0.516424E+10 | 0.247010E+10 |
May | 0.423935E+10 | 0.867945E+09 | 0.337140E+10 | 0.492384E+10 | 0.153335E+10 |
June | 0.387386E+10 | 0.596881E+09 | 0.327698E+10 | 0.516495E+10 | 0.735757E+09 |
July | 0.416513E+10 | 0.702990E+09 | 0.346214E+10 | 0.610973E+10 | 0.343841E+09 |
August | 0.557879E+10 | 0.205796E+10 | 0.352082E+10 | 0.812851E+10 | 0.547074E+09 |
September | 0.569723E+10 | 0.286050E+10 | 0.283673E+10 | 0.742407E+10 | 0.114749E+10 |
October | 0.831952E+10 | 0.521704E+10 | 0.310247E+10 | 0.100345E+11 | 0.233615E+10 |
November | 0.557489E+10 | 0.334422E+10 | 0.223067E+10 | 0.575928E+10 | 0.339396E+10 |
December | 0.571380E+10 | 0.405823E+10 | 0.165556E+10 | 0.568600E+10 | 0.444087E+10 |
Annual Sum or Average | 0.657506E+11 | 0.327240E+11 | 0.330267E+11 | 0.760140E+11 | 0.297543E+11 |
Minimum of Months | 0.387386E+10 | 0.596881E+09 | 0.165556E+10 | 0.492384E+10 | 0.343841E+09 |
Maximum of Months | 0.831952E+10 | 0.521704E+10 | 0.352082E+10 | 0.100345E+11 | 0.488166E+10 |
Report: WindowEnergyReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.687025E+10 | 0.450835E+10 | 0.236190E+10 | 0.668550E+10 | 0.666308E+10 |
February | 0.821220E+10 | 0.545806E+10 | 0.275414E+10 | 0.815862E+10 | 0.592547E+10 |
March | 0.805558E+10 | 0.443450E+10 | 0.362108E+10 | 0.845812E+10 | 0.483547E+10 |
April | 0.620519E+10 | 0.251047E+10 | 0.369472E+10 | 0.682635E+10 | 0.339148E+10 |
May | 0.550715E+10 | 0.112751E+10 | 0.437965E+10 | 0.650006E+10 | 0.211276E+10 |
June | 0.503236E+10 | 0.775382E+09 | 0.425698E+10 | 0.684172E+10 | 0.991455E+09 |
July | 0.541074E+10 | 0.913224E+09 | 0.449752E+10 | 0.811838E+10 | 0.451539E+09 |
August | 0.724716E+10 | 0.267341E+10 | 0.457375E+10 | 0.107954E+11 | 0.704559E+09 |
September | 0.740102E+10 | 0.371595E+10 | 0.368507E+10 | 0.981876E+10 | 0.153466E+10 |
October | 0.108075E+11 | 0.677724E+10 | 0.403029E+10 | 0.132772E+11 | 0.310787E+10 |
November | 0.724209E+10 | 0.434433E+10 | 0.289776E+10 | 0.759371E+10 | 0.464802E+10 |
December | 0.742255E+10 | 0.527188E+10 | 0.215067E+10 | 0.750037E+10 | 0.607307E+10 |
Annual Sum or Average | 0.854138E+11 | 0.425103E+11 | 0.429035E+11 | 0.100574E+12 | 0.404394E+11 |
Minimum of Months | 0.503236E+10 | 0.775382E+09 | 0.215067E+10 | 0.650006E+10 | 0.451539E+09 |
Maximum of Months | 0.108075E+11 | 0.677724E+10 | 0.457375E+10 | 0.132772E+11 | 0.666308E+10 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.371336E+09 | 0.243675E+09 | 0.127661E+09 | 0.362905E+09 | 0.336283E+09 |
February | 0.443868E+09 | 0.295007E+09 | 0.148862E+09 | 0.441692E+09 | 0.301282E+09 |
March | 0.435404E+09 | 0.239684E+09 | 0.195720E+09 | 0.456148E+09 | 0.237327E+09 |
April | 0.335391E+09 | 0.135690E+09 | 0.199700E+09 | 0.369382E+09 | 0.160797E+09 |
May | 0.297663E+09 | 60941606.69 | 0.236721E+09 | 0.353151E+09 | 93146835.19 |
June | 0.272000E+09 | 41909203.44 | 0.230091E+09 | 0.375688E+09 | 34715035.74 |
July | 0.292452E+09 | 49359538.74 | 0.243092E+09 | 0.452503E+09 | 9105150.51 |
August | 0.391710E+09 | 0.144497E+09 | 0.247212E+09 | 0.596152E+09 | 21503058.71 |
September | 0.400025E+09 | 0.200846E+09 | 0.199179E+09 | 0.536676E+09 | 58724013.72 |
October | 0.584146E+09 | 0.366308E+09 | 0.217837E+09 | 0.719366E+09 | 0.140070E+09 |
November | 0.391434E+09 | 0.234810E+09 | 0.156624E+09 | 0.415901E+09 | 0.222324E+09 |
December | 0.401187E+09 | 0.284944E+09 | 0.116244E+09 | 0.409137E+09 | 0.299756E+09 |
Annual Sum or Average | 0.461662E+10 | 0.229767E+10 | 0.231894E+10 | 0.548870E+10 | 0.191503E+10 |
Minimum of Months | 0.272000E+09 | 41909203.44 | 0.116244E+09 | 0.353151E+09 | 9105150.51 |
Maximum of Months | 0.584146E+09 | 0.366308E+09 | 0.247212E+09 | 0.719366E+09 | 0.336283E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.275986E+09 | 0.113300E+09 | 0.162686E+09 | 0.166864E+09 | 0.676130E+09 |
February | 0.366176E+09 | 0.160704E+09 | 0.205472E+09 | 0.246503E+09 | 0.616511E+09 |
March | 0.602184E+09 | 0.279066E+09 | 0.323119E+09 | 0.534067E+09 | 0.441625E+09 |
April | 0.632930E+09 | 0.270479E+09 | 0.362451E+09 | 0.648406E+09 | 0.293379E+09 |
May | 0.764046E+09 | 0.290443E+09 | 0.473603E+09 | 0.897535E+09 | 0.168918E+09 |
June | 0.807850E+09 | 0.326026E+09 | 0.481824E+09 | 0.107315E+10 | 63439759.33 |
July | 0.781005E+09 | 0.293491E+09 | 0.487514E+09 | 0.112832E+10 | 16796150.21 |
August | 0.864094E+09 | 0.399519E+09 | 0.464575E+09 | 0.123280E+10 | 39857094.96 |
September | 0.594954E+09 | 0.259739E+09 | 0.335215E+09 | 0.757111E+09 | 0.109861E+09 |
October | 0.610005E+09 | 0.297155E+09 | 0.312850E+09 | 0.682002E+09 | 0.268725E+09 |
November | 0.278002E+09 | 81216406.75 | 0.196786E+09 | 0.190713E+09 | 0.439787E+09 |
December | 0.253740E+09 | 0.109532E+09 | 0.144208E+09 | 0.156881E+09 | 0.612315E+09 |
Annual Sum or Average | 0.683097E+10 | 0.288067E+10 | 0.395030E+10 | 0.771434E+10 | 0.374735E+10 |
Minimum of Months | 0.253740E+09 | 81216406.75 | 0.144208E+09 | 0.156881E+09 | 16796150.21 |
Maximum of Months | 0.864094E+09 | 0.399519E+09 | 0.487514E+09 | 0.123280E+10 | 0.676130E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 71441120.58 | 0.00 | 71441120.58 | 5967491.99 | 0.374641E+09 |
February | 88303223.66 | 0.00 | 88303223.66 | 10557105.63 | 0.345392E+09 |
March | 0.135606E+09 | 2824.51 | 0.135604E+09 | 53881037.94 | 0.247082E+09 |
April | 0.157926E+09 | 650731.43 | 0.157276E+09 | 0.108157E+09 | 0.158028E+09 |
May | 0.217051E+09 | 7943454.65 | 0.209108E+09 | 0.218912E+09 | 86699783.75 |
June | 0.221597E+09 | 11786401.62 | 0.209811E+09 | 0.288495E+09 | 32759229.80 |
July | 0.222253E+09 | 8673946.39 | 0.213579E+09 | 0.337034E+09 | 8836045.39 |
August | 0.196546E+09 | 2611506.30 | 0.193935E+09 | 0.295487E+09 | 20438986.45 |
September | 0.143220E+09 | 83260.91 | 0.143137E+09 | 0.166977E+09 | 57932554.47 |
October | 0.127973E+09 | 0.00 | 0.127973E+09 | 0.103669E+09 | 0.143412E+09 |
November | 86865075.47 | 0.00 | 86865075.47 | 29985856.48 | 0.238270E+09 |
December | 62315669.45 | 0.00 | 62315669.45 | 4165019.77 | 0.337513E+09 |
Annual Sum or Average | 0.173110E+10 | 31752125.80 | 0.169935E+10 | 0.162329E+10 | 0.205101E+10 |
Minimum of Months | 62315669.45 | 0.00 | 62315669.45 | 4165019.77 | 8836045.39 |
Maximum of Months | 0.222253E+09 | 11786401.62 | 0.213579E+09 | 0.337034E+09 | 0.374641E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.275986E+09 | 0.113300E+09 | 0.162686E+09 | 0.175000E+09 | 0.669393E+09 |
February | 0.366176E+09 | 0.160704E+09 | 0.205472E+09 | 0.257684E+09 | 0.607331E+09 |
March | 0.602184E+09 | 0.279066E+09 | 0.323119E+09 | 0.547886E+09 | 0.435129E+09 |
April | 0.632930E+09 | 0.270479E+09 | 0.362451E+09 | 0.656923E+09 | 0.290462E+09 |
May | 0.764046E+09 | 0.290443E+09 | 0.473603E+09 | 0.901330E+09 | 0.168004E+09 |
June | 0.807850E+09 | 0.326026E+09 | 0.481824E+09 | 0.107519E+10 | 62976002.70 |
July | 0.781005E+09 | 0.293491E+09 | 0.487514E+09 | 0.113085E+10 | 16494007.00 |
August | 0.864094E+09 | 0.399519E+09 | 0.464575E+09 | 0.123894E+10 | 38742029.36 |
September | 0.594954E+09 | 0.259739E+09 | 0.335215E+09 | 0.765385E+09 | 0.107159E+09 |
October | 0.610005E+09 | 0.297155E+09 | 0.312850E+09 | 0.697118E+09 | 0.261946E+09 |
November | 0.278002E+09 | 81216406.75 | 0.196786E+09 | 0.201675E+09 | 0.432343E+09 |
December | 0.253740E+09 | 0.109532E+09 | 0.144208E+09 | 0.166509E+09 | 0.603722E+09 |
Annual Sum or Average | 0.683097E+10 | 0.288067E+10 | 0.395030E+10 | 0.781450E+10 | 0.369370E+10 |
Minimum of Months | 0.253740E+09 | 81216406.75 | 0.144208E+09 | 0.166509E+09 | 16494007.00 |
Maximum of Months | 0.864094E+09 | 0.399519E+09 | 0.487514E+09 | 0.123894E+10 | 0.669393E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.297010E+09 | 0.194901E+09 | 0.102108E+09 | 0.289244E+09 | 0.261477E+09 |
February | 0.355024E+09 | 0.235958E+09 | 0.119066E+09 | 0.349229E+09 | 0.243422E+09 |
March | 0.348254E+09 | 0.191709E+09 | 0.156545E+09 | 0.361686E+09 | 0.197435E+09 |
April | 0.268259E+09 | 0.108531E+09 | 0.159729E+09 | 0.292304E+09 | 0.136938E+09 |
May | 0.238083E+09 | 48743591.57 | 0.189339E+09 | 0.277222E+09 | 86334040.19 |
June | 0.217557E+09 | 33520696.39 | 0.184036E+09 | 0.295916E+09 | 37667383.94 |
July | 0.233915E+09 | 39479779.53 | 0.194435E+09 | 0.354339E+09 | 14581042.49 |
August | 0.313305E+09 | 0.115575E+09 | 0.197731E+09 | 0.470218E+09 | 25307151.50 |
September | 0.319956E+09 | 0.160645E+09 | 0.159311E+09 | 0.422922E+09 | 61007818.16 |
October | 0.467223E+09 | 0.292988E+09 | 0.174235E+09 | 0.567322E+09 | 0.131883E+09 |
November | 0.313085E+09 | 0.187811E+09 | 0.125275E+09 | 0.325928E+09 | 0.188638E+09 |
December | 0.320886E+09 | 0.227910E+09 | 92976446.14 | 0.323239E+09 | 0.240881E+09 |
Annual Sum or Average | 0.369256E+10 | 0.183777E+10 | 0.185479E+10 | 0.432957E+10 | 0.162557E+10 |
Minimum of Months | 0.217557E+09 | 33520696.39 | 92976446.14 | 0.277222E+09 | 14581042.49 |
Maximum of Months | 0.467223E+09 | 0.292988E+09 | 0.197731E+09 | 0.567322E+09 | 0.261477E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 57160472.40 | 0.00 | 57160472.40 | 3788975.13 | 0.312862E+09 |
February | 70651943.00 | 0.00 | 70651943.00 | 7619990.17 | 0.285580E+09 |
March | 0.108500E+09 | 2259.91 | 0.108497E+09 | 43383682.13 | 0.201212E+09 |
April | 0.126358E+09 | 520654.15 | 0.125837E+09 | 89873410.25 | 0.127255E+09 |
May | 0.173664E+09 | 6355606.08 | 0.167308E+09 | 0.183712E+09 | 67581883.40 |
June | 0.177301E+09 | 9430371.18 | 0.167871E+09 | 0.243495E+09 | 22738375.97 |
July | 0.177826E+09 | 6940076.94 | 0.170886E+09 | 0.284291E+09 | 4822951.90 |
August | 0.157258E+09 | 2089481.97 | 0.155168E+09 | 0.252164E+09 | 13099673.25 |
September | 0.114591E+09 | 66617.56 | 0.114525E+09 | 0.142890E+09 | 42613322.58 |
October | 0.102392E+09 | 0.00 | 0.102392E+09 | 88452923.59 | 0.111895E+09 |
November | 69501271.94 | 0.00 | 69501271.94 | 23112353.82 | 0.198561E+09 |
December | 49859143.80 | 0.00 | 49859143.80 | 2616352.80 | 0.282667E+09 |
Annual Sum or Average | 0.138506E+10 | 25405067.78 | 0.135966E+10 | 0.136540E+10 | 0.167089E+10 |
Minimum of Months | 49859143.80 | 0.00 | 49859143.80 | 2616352.80 | 4822951.90 |
Maximum of Months | 0.177826E+09 | 9430371.18 | 0.170886E+09 | 0.284291E+09 | 0.312862E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277917E+09 | 0.111036E+09 | 0.166880E+09 | 0.163939E+09 | 0.664824E+09 |
February | 0.389732E+09 | 0.181489E+09 | 0.208243E+09 | 0.263328E+09 | 0.594547E+09 |
March | 0.554101E+09 | 0.235489E+09 | 0.318612E+09 | 0.475812E+09 | 0.443169E+09 |
April | 0.641909E+09 | 0.281741E+09 | 0.360168E+09 | 0.653005E+09 | 0.284791E+09 |
May | 0.800805E+09 | 0.319132E+09 | 0.481673E+09 | 0.942568E+09 | 0.163751E+09 |
June | 0.719622E+09 | 0.260655E+09 | 0.458966E+09 | 0.956996E+09 | 60536965.87 |
July | 0.745874E+09 | 0.268526E+09 | 0.477348E+09 | 0.108455E+10 | 15871570.64 |
August | 0.841430E+09 | 0.379618E+09 | 0.461812E+09 | 0.120163E+10 | 37373538.15 |
September | 0.609123E+09 | 0.274405E+09 | 0.334718E+09 | 0.773042E+09 | 0.105526E+09 |
October | 0.568633E+09 | 0.257394E+09 | 0.311239E+09 | 0.625989E+09 | 0.261756E+09 |
November | 0.340829E+09 | 0.130973E+09 | 0.209856E+09 | 0.269161E+09 | 0.429258E+09 |
December | 0.275346E+09 | 0.129921E+09 | 0.145425E+09 | 0.179176E+09 | 0.597342E+09 |
Annual Sum or Average | 0.676532E+10 | 0.283038E+10 | 0.393494E+10 | 0.758920E+10 | 0.365875E+10 |
Minimum of Months | 0.275346E+09 | 0.111036E+09 | 0.145425E+09 | 0.163939E+09 | 15871570.64 |
Maximum of Months | 0.841430E+09 | 0.379618E+09 | 0.481673E+09 | 0.120163E+10 | 0.664824E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.371336E+09 | 0.243675E+09 | 0.127661E+09 | 0.362157E+09 | 0.335764E+09 |
February | 0.443868E+09 | 0.295007E+09 | 0.148862E+09 | 0.439956E+09 | 0.300484E+09 |
March | 0.435404E+09 | 0.239684E+09 | 0.195720E+09 | 0.453674E+09 | 0.235012E+09 |
April | 0.335391E+09 | 0.135690E+09 | 0.199700E+09 | 0.366410E+09 | 0.159528E+09 |
May | 0.297663E+09 | 60941606.69 | 0.236721E+09 | 0.350238E+09 | 91863285.24 |
June | 0.272000E+09 | 41909203.44 | 0.230091E+09 | 0.375633E+09 | 33494264.38 |
July | 0.292452E+09 | 49359538.74 | 0.243092E+09 | 0.452256E+09 | 8570053.80 |
August | 0.391710E+09 | 0.144497E+09 | 0.247212E+09 | 0.595391E+09 | 20678023.05 |
September | 0.400025E+09 | 0.200846E+09 | 0.199179E+09 | 0.535165E+09 | 57871516.29 |
October | 0.584146E+09 | 0.366308E+09 | 0.217837E+09 | 0.717682E+09 | 0.138612E+09 |
November | 0.391434E+09 | 0.234810E+09 | 0.156624E+09 | 0.413702E+09 | 0.222601E+09 |
December | 0.401187E+09 | 0.284944E+09 | 0.116244E+09 | 0.408007E+09 | 0.299365E+09 |
Annual Sum or Average | 0.461662E+10 | 0.229767E+10 | 0.231894E+10 | 0.547027E+10 | 0.190385E+10 |
Minimum of Months | 0.272000E+09 | 41909203.44 | 0.116244E+09 | 0.350238E+09 | 8570053.80 |
Maximum of Months | 0.584146E+09 | 0.366308E+09 | 0.247212E+09 | 0.717682E+09 | 0.335764E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 71441120.58 | 0.00 | 71441120.58 | 5490725.15 | 0.374515E+09 |
February | 88303223.66 | 0.00 | 88303223.66 | 9891443.37 | 0.345213E+09 |
March | 0.135606E+09 | 2824.51 | 0.135604E+09 | 51605040.04 | 0.244837E+09 |
April | 0.157926E+09 | 650731.43 | 0.157276E+09 | 0.104980E+09 | 0.157185E+09 |
May | 0.217051E+09 | 7943454.65 | 0.209108E+09 | 0.215809E+09 | 85749098.29 |
June | 0.221597E+09 | 11786401.62 | 0.209811E+09 | 0.288427E+09 | 31699766.35 |
July | 0.222253E+09 | 8673946.39 | 0.213579E+09 | 0.336705E+09 | 8337590.82 |
August | 0.196546E+09 | 2611506.30 | 0.193935E+09 | 0.294398E+09 | 19642592.02 |
September | 0.143220E+09 | 83260.91 | 0.143137E+09 | 0.164852E+09 | 57186569.91 |
October | 0.127973E+09 | 0.00 | 0.127973E+09 | 0.101051E+09 | 0.141529E+09 |
November | 86865075.47 | 0.00 | 86865075.47 | 28368042.41 | 0.238819E+09 |
December | 62315669.45 | 0.00 | 62315669.45 | 3671556.39 | 0.337336E+09 |
Annual Sum or Average | 0.173110E+10 | 31752125.80 | 0.169935E+10 | 0.160525E+10 | 0.204205E+10 |
Minimum of Months | 62315669.45 | 0.00 | 62315669.45 | 3671556.39 | 8337590.82 |
Maximum of Months | 0.222253E+09 | 11786401.62 | 0.213579E+09 | 0.336705E+09 | 0.374515E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277917E+09 | 0.111036E+09 | 0.166880E+09 | 0.169308E+09 | 0.655425E+09 |
February | 0.389732E+09 | 0.181489E+09 | 0.208243E+09 | 0.271464E+09 | 0.581776E+09 |
March | 0.554101E+09 | 0.235489E+09 | 0.318612E+09 | 0.488366E+09 | 0.435031E+09 |
April | 0.641909E+09 | 0.281741E+09 | 0.360168E+09 | 0.660348E+09 | 0.281565E+09 |
May | 0.800805E+09 | 0.319132E+09 | 0.481673E+09 | 0.945641E+09 | 0.162833E+09 |
June | 0.719622E+09 | 0.260655E+09 | 0.458966E+09 | 0.958957E+09 | 60110630.48 |
July | 0.745874E+09 | 0.268526E+09 | 0.477348E+09 | 0.108708E+10 | 15601648.25 |
August | 0.841430E+09 | 0.379618E+09 | 0.461812E+09 | 0.120747E+10 | 36284108.36 |
September | 0.609123E+09 | 0.274405E+09 | 0.334718E+09 | 0.780257E+09 | 0.102765E+09 |
October | 0.568633E+09 | 0.257394E+09 | 0.311239E+09 | 0.639706E+09 | 0.254108E+09 |
November | 0.340829E+09 | 0.130973E+09 | 0.209856E+09 | 0.278678E+09 | 0.420211E+09 |
December | 0.275346E+09 | 0.129921E+09 | 0.145425E+09 | 0.185122E+09 | 0.584597E+09 |
Annual Sum or Average | 0.676532E+10 | 0.283038E+10 | 0.393494E+10 | 0.767240E+10 | 0.359031E+10 |
Minimum of Months | 0.275346E+09 | 0.111036E+09 | 0.145425E+09 | 0.169308E+09 | 15601648.25 |
Maximum of Months | 0.841430E+09 | 0.379618E+09 | 0.481673E+09 | 0.120747E+10 | 0.655425E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90475671.53 | 0.00 | 90475671.53 | 4454844.01 | 0.514057E+09 |
February | 0.111830E+09 | 0.00 | 0.111830E+09 | 9981855.12 | 0.470320E+09 |
March | 0.171737E+09 | 3577.06 | 0.171733E+09 | 63903544.73 | 0.331618E+09 |
April | 0.200004E+09 | 824110.29 | 0.199180E+09 | 0.136228E+09 | 0.215336E+09 |
May | 0.274881E+09 | 10059884.11 | 0.264822E+09 | 0.277762E+09 | 0.123521E+09 |
June | 0.280639E+09 | 14926733.97 | 0.265712E+09 | 0.360034E+09 | 57354825.06 |
July | 0.281470E+09 | 10985005.81 | 0.270485E+09 | 0.413187E+09 | 24514411.72 |
August | 0.248914E+09 | 3307307.95 | 0.245606E+09 | 0.359897E+09 | 41243447.20 |
September | 0.181379E+09 | 105444.69 | 0.181274E+09 | 0.204016E+09 | 95236599.99 |
October | 0.162070E+09 | 0.00 | 0.162070E+09 | 0.124494E+09 | 0.208539E+09 |
November | 0.110009E+09 | 0.00 | 0.110009E+09 | 32413948.66 | 0.330879E+09 |
December | 78918863.46 | 0.00 | 78918863.46 | 3038009.83 | 0.465989E+09 |
Annual Sum or Average | 0.219233E+10 | 40212063.88 | 0.215212E+10 | 0.198941E+10 | 0.287861E+10 |
Minimum of Months | 78918863.46 | 0.00 | 78918863.46 | 3038009.83 | 24514411.72 |
Maximum of Months | 0.281470E+09 | 14926733.97 | 0.270485E+09 | 0.413187E+09 | 0.514057E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 33353078.83 | 0.00 | 33353078.83 | 1642239.96 | 0.189503E+09 |
February | 41225338.51 | 0.00 | 41225338.51 | 3679725.11 | 0.173379E+09 |
March | 63309370.74 | 1318.65 | 63308052.09 | 23557492.62 | 0.122248E+09 |
April | 73729728.02 | 303801.18 | 73425926.85 | 50219387.14 | 79381894.44 |
May | 0.101333E+09 | 3708489.83 | 97624177.01 | 0.102395E+09 | 45534939.84 |
June | 0.103455E+09 | 5502612.21 | 97952429.60 | 0.132724E+09 | 21143363.39 |
July | 0.103761E+09 | 4049527.99 | 99711821.83 | 0.152318E+09 | 9037027.22 |
August | 91759824.79 | 1219210.65 | 90540614.14 | 0.132673E+09 | 15204042.40 |
September | 66863956.86 | 38871.28 | 66825085.58 | 75208592.04 | 35108154.19 |
October | 59745607.08 | 0.00 | 59745607.08 | 45893512.25 | 76876089.20 |
November | 40553923.09 | 0.00 | 40553923.09 | 11949123.63 | 0.121976E+09 |
December | 29092760.85 | 0.00 | 29092760.85 | 1119936.22 | 0.171783E+09 |
Annual Sum or Average | 0.808183E+09 | 14823831.80 | 0.793359E+09 | 0.733379E+09 | 0.106117E+10 |
Minimum of Months | 29092760.85 | 0.00 | 29092760.85 | 1119936.22 | 9037027.22 |
Maximum of Months | 0.103761E+09 | 5502612.21 | 99711821.83 | 0.152318E+09 | 0.189503E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.173264E+09 | 0.113698E+09 | 59565921.67 | 0.168031E+09 | 0.166502E+09 |
February | 0.207107E+09 | 0.137649E+09 | 69458271.60 | 0.205522E+09 | 0.147535E+09 |
March | 0.203158E+09 | 0.111836E+09 | 91322098.46 | 0.214286E+09 | 0.115541E+09 |
April | 0.156492E+09 | 63312522.45 | 93179403.01 | 0.173798E+09 | 79641905.94 |
May | 0.138888E+09 | 28435108.11 | 0.110453E+09 | 0.166002E+09 | 48606504.30 |
June | 0.126914E+09 | 19554665.45 | 0.107360E+09 | 0.174033E+09 | 22321022.86 |
July | 0.136457E+09 | 23030961.87 | 0.113426E+09 | 0.206683E+09 | 9222854.02 |
August | 0.182770E+09 | 67421861.27 | 0.115348E+09 | 0.274302E+09 | 15630161.23 |
September | 0.186650E+09 | 93714060.14 | 92935999.63 | 0.249352E+09 | 34726931.00 |
October | 0.272560E+09 | 0.170918E+09 | 0.101642E+09 | 0.336643E+09 | 72994606.06 |
November | 0.182642E+09 | 0.109561E+09 | 73080255.50 | 0.193399E+09 | 0.110638E+09 |
December | 0.187192E+09 | 0.132954E+09 | 54238828.37 | 0.190180E+09 | 0.148261E+09 |
Annual Sum or Average | 0.215409E+10 | 0.107208E+10 | 0.108201E+10 | 0.255223E+10 | 0.971621E+09 |
Minimum of Months | 0.126914E+09 | 19554665.45 | 54238828.37 | 0.166002E+09 | 9222854.02 |
Maximum of Months | 0.272560E+09 | 0.170918E+09 | 0.115348E+09 | 0.336643E+09 | 0.166502E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.470274E+09 | 0.308599E+09 | 0.161674E+09 | 0.456071E+09 | 0.451922E+09 |
February | 0.562131E+09 | 0.373607E+09 | 0.188524E+09 | 0.557829E+09 | 0.400439E+09 |
March | 0.551411E+09 | 0.303545E+09 | 0.247867E+09 | 0.581615E+09 | 0.313603E+09 |
April | 0.424751E+09 | 0.171843E+09 | 0.252908E+09 | 0.471724E+09 | 0.216164E+09 |
May | 0.376971E+09 | 77178699.67 | 0.299792E+09 | 0.450564E+09 | 0.131928E+09 |
June | 0.344471E+09 | 53075361.84 | 0.291396E+09 | 0.472362E+09 | 60583821.72 |
July | 0.370372E+09 | 62510741.40 | 0.307861E+09 | 0.560980E+09 | 25032712.30 |
August | 0.496076E+09 | 0.182997E+09 | 0.313079E+09 | 0.744511E+09 | 42423454.66 |
September | 0.506606E+09 | 0.254359E+09 | 0.252247E+09 | 0.676792E+09 | 94255993.96 |
October | 0.739783E+09 | 0.463906E+09 | 0.275877E+09 | 0.913718E+09 | 0.198122E+09 |
November | 0.495727E+09 | 0.297372E+09 | 0.198355E+09 | 0.524924E+09 | 0.300293E+09 |
December | 0.508078E+09 | 0.360863E+09 | 0.147215E+09 | 0.516187E+09 | 0.402411E+09 |
Annual Sum or Average | 0.584665E+10 | 0.290986E+10 | 0.293680E+10 | 0.692728E+10 | 0.263718E+10 |
Minimum of Months | 0.344471E+09 | 53075361.84 | 0.147215E+09 | 0.450564E+09 | 25032712.30 |
Maximum of Months | 0.739783E+09 | 0.463906E+09 | 0.313079E+09 | 0.913718E+09 | 0.451922E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.371336E+09 | 0.243675E+09 | 0.127661E+09 | 0.361929E+09 | 0.334402E+09 |
February | 0.443868E+09 | 0.295007E+09 | 0.148862E+09 | 0.440252E+09 | 0.299931E+09 |
March | 0.435404E+09 | 0.239684E+09 | 0.195720E+09 | 0.453690E+09 | 0.236210E+09 |
April | 0.335391E+09 | 0.135690E+09 | 0.199700E+09 | 0.366885E+09 | 0.159571E+09 |
May | 0.297663E+09 | 60941606.69 | 0.236721E+09 | 0.349950E+09 | 92192595.02 |
June | 0.272000E+09 | 41909203.44 | 0.230091E+09 | 0.372825E+09 | 33641360.52 |
July | 0.292452E+09 | 49359538.74 | 0.243092E+09 | 0.450000E+09 | 8327366.95 |
August | 0.391710E+09 | 0.144497E+09 | 0.247212E+09 | 0.593200E+09 | 20345493.04 |
September | 0.400025E+09 | 0.200846E+09 | 0.199179E+09 | 0.533897E+09 | 57008703.89 |
October | 0.584146E+09 | 0.366308E+09 | 0.217837E+09 | 0.716112E+09 | 0.137656E+09 |
November | 0.391434E+09 | 0.234810E+09 | 0.156624E+09 | 0.415207E+09 | 0.219667E+09 |
December | 0.401187E+09 | 0.284944E+09 | 0.116244E+09 | 0.408433E+09 | 0.297390E+09 |
Annual Sum or Average | 0.461662E+10 | 0.229767E+10 | 0.231894E+10 | 0.546238E+10 | 0.189634E+10 |
Minimum of Months | 0.272000E+09 | 41909203.44 | 0.116244E+09 | 0.349950E+09 | 8327366.95 |
Maximum of Months | 0.584146E+09 | 0.366308E+09 | 0.247212E+09 | 0.716112E+09 | 0.334402E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.275986E+09 | 0.113300E+09 | 0.162686E+09 | 0.166634E+09 | 0.672794E+09 |
February | 0.366176E+09 | 0.160704E+09 | 0.205472E+09 | 0.245054E+09 | 0.614536E+09 |
March | 0.602184E+09 | 0.279066E+09 | 0.323119E+09 | 0.530600E+09 | 0.438837E+09 |
April | 0.632930E+09 | 0.270479E+09 | 0.362451E+09 | 0.644227E+09 | 0.290523E+09 |
May | 0.764046E+09 | 0.290443E+09 | 0.473603E+09 | 0.891098E+09 | 0.166705E+09 |
June | 0.807850E+09 | 0.326026E+09 | 0.481824E+09 | 0.106622E+10 | 61308946.25 |
July | 0.781005E+09 | 0.293491E+09 | 0.487514E+09 | 0.112264E+10 | 15337710.14 |
August | 0.864094E+09 | 0.399519E+09 | 0.464575E+09 | 0.122764E+10 | 37654263.42 |
September | 0.594954E+09 | 0.259739E+09 | 0.335215E+09 | 0.753411E+09 | 0.106468E+09 |
October | 0.610005E+09 | 0.297155E+09 | 0.312850E+09 | 0.678592E+09 | 0.263792E+09 |
November | 0.278002E+09 | 81216406.75 | 0.196786E+09 | 0.190962E+09 | 0.434680E+09 |
December | 0.253740E+09 | 0.109532E+09 | 0.144208E+09 | 0.156843E+09 | 0.607629E+09 |
Annual Sum or Average | 0.683097E+10 | 0.288067E+10 | 0.395030E+10 | 0.767392E+10 | 0.371026E+10 |
Minimum of Months | 0.253740E+09 | 81216406.75 | 0.144208E+09 | 0.156843E+09 | 15337710.14 |
Maximum of Months | 0.864094E+09 | 0.399519E+09 | 0.487514E+09 | 0.122764E+10 | 0.672794E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 71441120.58 | 0.00 | 71441120.58 | 6192480.38 | 0.372820E+09 |
February | 88303223.66 | 0.00 | 88303223.66 | 10770782.08 | 0.344476E+09 |
March | 0.135606E+09 | 2824.51 | 0.135604E+09 | 54126533.93 | 0.245706E+09 |
April | 0.157926E+09 | 650731.43 | 0.157276E+09 | 0.107948E+09 | 0.156485E+09 |
May | 0.217051E+09 | 7943454.65 | 0.209108E+09 | 0.216875E+09 | 85710249.80 |
June | 0.221597E+09 | 11786401.62 | 0.209811E+09 | 0.286638E+09 | 31735699.91 |
July | 0.222253E+09 | 8673946.39 | 0.213579E+09 | 0.335481E+09 | 8162861.62 |
August | 0.196546E+09 | 2611506.30 | 0.193935E+09 | 0.294711E+09 | 19316824.29 |
September | 0.143220E+09 | 83260.91 | 0.143137E+09 | 0.166577E+09 | 56082094.17 |
October | 0.127973E+09 | 0.00 | 0.127973E+09 | 0.104569E+09 | 0.140261E+09 |
November | 86865075.47 | 0.00 | 86865075.47 | 30861812.13 | 0.234997E+09 |
December | 62315669.45 | 0.00 | 62315669.45 | 4463079.65 | 0.334591E+09 |
Annual Sum or Average | 0.173110E+10 | 31752125.80 | 0.169935E+10 | 0.161921E+10 | 0.203034E+10 |
Minimum of Months | 62315669.45 | 0.00 | 62315669.45 | 4463079.65 | 8162861.62 |
Maximum of Months | 0.222253E+09 | 11786401.62 | 0.213579E+09 | 0.335481E+09 | 0.372820E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.275986E+09 | 0.113300E+09 | 0.162686E+09 | 0.174706E+09 | 0.666413E+09 |
February | 0.366176E+09 | 0.160704E+09 | 0.205472E+09 | 0.256512E+09 | 0.605691E+09 |
March | 0.602184E+09 | 0.279066E+09 | 0.323119E+09 | 0.545457E+09 | 0.432044E+09 |
April | 0.632930E+09 | 0.270479E+09 | 0.362451E+09 | 0.653387E+09 | 0.287373E+09 |
May | 0.764046E+09 | 0.290443E+09 | 0.473603E+09 | 0.895000E+09 | 0.165738E+09 |
June | 0.807850E+09 | 0.326026E+09 | 0.481824E+09 | 0.106830E+10 | 60861764.39 |
July | 0.781005E+09 | 0.293491E+09 | 0.487514E+09 | 0.112526E+10 | 15049853.71 |
August | 0.864094E+09 | 0.399519E+09 | 0.464575E+09 | 0.123410E+10 | 36475732.62 |
September | 0.594954E+09 | 0.259739E+09 | 0.335215E+09 | 0.762272E+09 | 0.103472E+09 |
October | 0.610005E+09 | 0.297155E+09 | 0.312850E+09 | 0.695698E+09 | 0.255892E+09 |
November | 0.278002E+09 | 81216406.75 | 0.196786E+09 | 0.202736E+09 | 0.426928E+09 |
December | 0.253740E+09 | 0.109532E+09 | 0.144208E+09 | 0.166893E+09 | 0.599349E+09 |
Annual Sum or Average | 0.683097E+10 | 0.288067E+10 | 0.395030E+10 | 0.778032E+10 | 0.365529E+10 |
Minimum of Months | 0.253740E+09 | 81216406.75 | 0.144208E+09 | 0.166893E+09 | 15049853.71 |
Maximum of Months | 0.864094E+09 | 0.399519E+09 | 0.487514E+09 | 0.123410E+10 | 0.666413E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.544600E+09 | 0.357373E+09 | 0.187227E+09 | 0.514317E+09 | 0.509143E+09 |
February | 0.650976E+09 | 0.432656E+09 | 0.218320E+09 | 0.626423E+09 | 0.457531E+09 |
March | 0.638561E+09 | 0.351519E+09 | 0.287042E+09 | 0.653513E+09 | 0.356085E+09 |
April | 0.491883E+09 | 0.199003E+09 | 0.292880E+09 | 0.533158E+09 | 0.236863E+09 |
May | 0.436551E+09 | 89376714.80 | 0.347174E+09 | 0.516509E+09 | 0.133232E+09 |
June | 0.398915E+09 | 61463868.89 | 0.337451E+09 | 0.555986E+09 | 45891613.01 |
July | 0.428908E+09 | 72390500.62 | 0.356518E+09 | 0.670620E+09 | 10234254.94 |
August | 0.574480E+09 | 0.211919E+09 | 0.362561E+09 | 0.878638E+09 | 27513527.85 |
September | 0.586675E+09 | 0.294560E+09 | 0.292115E+09 | 0.782281E+09 | 83410388.13 |
October | 0.856705E+09 | 0.537226E+09 | 0.319480E+09 | 0.104103E+10 | 0.207312E+09 |
November | 0.574076E+09 | 0.344371E+09 | 0.229705E+09 | 0.592489E+09 | 0.339217E+09 |
December | 0.588380E+09 | 0.417897E+09 | 0.170482E+09 | 0.581071E+09 | 0.455752E+09 |
Annual Sum or Average | 0.677071E+10 | 0.336976E+10 | 0.340095E+10 | 0.794604E+10 | 0.286218E+10 |
Minimum of Months | 0.398915E+09 | 61463868.89 | 0.170482E+09 | 0.514317E+09 | 10234254.94 |
Maximum of Months | 0.856705E+09 | 0.537226E+09 | 0.362561E+09 | 0.104103E+10 | 0.509143E+09 |
Report: WindowEnergyReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.500069E+09 | 0.00 | 0.500069E+09 | 11159821.63 | 0.315464E+10 |
February | 0.618099E+09 | 0.00 | 0.618099E+09 | 34614031.82 | 0.287222E+10 |
March | 0.949209E+09 | 19770.80 | 0.949189E+09 | 0.276116E+09 | 0.211767E+10 |
April | 0.110544E+10 | 4554947.47 | 0.110089E+10 | 0.640459E+09 | 0.138749E+10 |
May | 0.151930E+10 | 55602076.65 | 0.146370E+10 | 0.138447E+10 | 0.783825E+09 |
June | 0.155112E+10 | 82501686.62 | 0.146862E+10 | 0.189835E+10 | 0.358325E+09 |
July | 0.155571E+10 | 60715325.16 | 0.149500E+10 | 0.221979E+10 | 0.157246E+09 |
August | 0.137577E+10 | 18279851.73 | 0.135749E+10 | 0.194628E+10 | 0.240249E+09 |
September | 0.100250E+10 | 582804.32 | 0.100192E+10 | 0.106673E+10 | 0.587043E+09 |
October | 0.895777E+09 | 0.00 | 0.895777E+09 | 0.629417E+09 | 0.125487E+10 |
November | 0.608032E+09 | 0.00 | 0.608032E+09 | 0.134807E+09 | 0.210220E+10 |
December | 0.436193E+09 | 0.00 | 0.436193E+09 | 7950607.59 | 0.291218E+10 |
Annual Sum or Average | 0.121172E+11 | 0.222256E+09 | 0.118950E+11 | 0.102501E+11 | 0.179279E+11 |
Minimum of Months | 0.436193E+09 | 0.00 | 0.436193E+09 | 7950607.59 | 0.157246E+09 |
Maximum of Months | 0.155571E+10 | 82501686.62 | 0.149500E+10 | 0.221979E+10 | 0.315464E+10 |
Report: WindowEnergyReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.500069E+09 | 0.00 | 0.500069E+09 | 7588443.67 | 0.324885E+10 |
February | 0.618099E+09 | 0.00 | 0.618099E+09 | 29170304.40 | 0.295327E+10 |
March | 0.949209E+09 | 19770.80 | 0.949189E+09 | 0.255415E+09 | 0.217993E+10 |
April | 0.110544E+10 | 4554947.47 | 0.110089E+10 | 0.612733E+09 | 0.142963E+10 |
May | 0.151930E+10 | 55602076.65 | 0.146370E+10 | 0.135279E+10 | 0.806096E+09 |
June | 0.155112E+10 | 82501686.62 | 0.146862E+10 | 0.187558E+10 | 0.372397E+09 |
July | 0.155571E+10 | 60715325.16 | 0.149500E+10 | 0.219908E+10 | 0.168115E+09 |
August | 0.137577E+10 | 18279851.73 | 0.135749E+10 | 0.192498E+10 | 0.251630E+09 |
September | 0.100250E+10 | 582804.32 | 0.100192E+10 | 0.104589E+10 | 0.608403E+09 |
October | 0.895777E+09 | 0.00 | 0.895777E+09 | 0.606690E+09 | 0.128942E+10 |
November | 0.608032E+09 | 0.00 | 0.608032E+09 | 0.122126E+09 | 0.217023E+10 |
December | 0.436193E+09 | 0.00 | 0.436193E+09 | 5819826.30 | 0.300042E+10 |
Annual Sum or Average | 0.121172E+11 | 0.222256E+09 | 0.118950E+11 | 0.100379E+11 | 0.184784E+11 |
Minimum of Months | 0.436193E+09 | 0.00 | 0.436193E+09 | 5819826.30 | 0.168115E+09 |
Maximum of Months | 0.155571E+10 | 82501686.62 | 0.149500E+10 | 0.219908E+10 | 0.324885E+10 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 71441120.58 | 0.00 | 71441120.58 | 6337811.45 | 0.402352E+09 |
February | 88303223.66 | 0.00 | 88303223.66 | 10575015.24 | 0.368363E+09 |
March | 0.135606E+09 | 2824.51 | 0.135604E+09 | 57850519.88 | 0.267559E+09 |
April | 0.157926E+09 | 650731.43 | 0.157276E+09 | 0.127219E+09 | 0.176768E+09 |
May | 0.217051E+09 | 7943454.65 | 0.209108E+09 | 0.257671E+09 | 0.103876E+09 |
June | 0.221597E+09 | 11786401.62 | 0.209811E+09 | 0.339746E+09 | 48310463.55 |
July | 0.222253E+09 | 8673946.39 | 0.213579E+09 | 0.394942E+09 | 22398294.11 |
August | 0.196546E+09 | 2611506.30 | 0.193935E+09 | 0.350586E+09 | 32268774.66 |
September | 0.143220E+09 | 83260.91 | 0.143137E+09 | 0.208184E+09 | 70558887.20 |
October | 0.127973E+09 | 0.00 | 0.127973E+09 | 0.126428E+09 | 0.152142E+09 |
November | 86865075.47 | 0.00 | 86865075.47 | 33313897.58 | 0.261809E+09 |
December | 62315669.45 | 0.00 | 62315669.45 | 4449316.77 | 0.364923E+09 |
Annual Sum or Average | 0.173110E+10 | 31752125.80 | 0.169935E+10 | 0.191730E+10 | 0.227133E+10 |
Minimum of Months | 62315669.45 | 0.00 | 62315669.45 | 4449316.77 | 22398294.11 |
Maximum of Months | 0.222253E+09 | 11786401.62 | 0.213579E+09 | 0.394942E+09 | 0.402352E+09 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.555794E+09 | 0.222057E+09 | 0.333737E+09 | 0.346890E+09 | 0.141264E+10 |
February | 0.779409E+09 | 0.362953E+09 | 0.416456E+09 | 0.553114E+09 | 0.124317E+10 |
March | 0.110812E+10 | 0.470944E+09 | 0.637179E+09 | 0.100978E+10 | 0.960451E+09 |
April | 0.128373E+10 | 0.563442E+09 | 0.720285E+09 | 0.140913E+10 | 0.639369E+09 |
May | 0.160150E+10 | 0.638219E+09 | 0.963277E+09 | 0.204141E+10 | 0.390935E+09 |
June | 0.143914E+10 | 0.521274E+09 | 0.917867E+09 | 0.210601E+10 | 0.181606E+09 |
July | 0.149164E+10 | 0.537013E+09 | 0.954629E+09 | 0.238850E+10 | 84396011.22 |
August | 0.168274E+10 | 0.759182E+09 | 0.923559E+09 | 0.262290E+10 | 0.120776E+09 |
September | 0.121816E+10 | 0.548771E+09 | 0.669389E+09 | 0.172500E+10 | 0.259190E+09 |
October | 0.113718E+10 | 0.514751E+09 | 0.622434E+09 | 0.138760E+10 | 0.552381E+09 |
November | 0.681609E+09 | 0.261927E+09 | 0.419682E+09 | 0.586371E+09 | 0.919122E+09 |
December | 0.550653E+09 | 0.259823E+09 | 0.290830E+09 | 0.381709E+09 | 0.126535E+10 |
Annual Sum or Average | 0.135297E+11 | 0.566036E+10 | 0.786932E+10 | 0.165584E+11 | 0.802939E+10 |
Minimum of Months | 0.550653E+09 | 0.222057E+09 | 0.290830E+09 | 0.346890E+09 | 84396011.22 |
Maximum of Months | 0.168274E+10 | 0.759182E+09 | 0.963277E+09 | 0.262290E+10 | 0.141264E+10 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.371336E+09 | 0.243675E+09 | 0.127661E+09 | 0.369507E+09 | 0.357778E+09 |
February | 0.443868E+09 | 0.295007E+09 | 0.148862E+09 | 0.450709E+09 | 0.315765E+09 |
March | 0.435404E+09 | 0.239684E+09 | 0.195720E+09 | 0.472913E+09 | 0.254915E+09 |
April | 0.335391E+09 | 0.135690E+09 | 0.199700E+09 | 0.393675E+09 | 0.177429E+09 |
May | 0.297663E+09 | 60941606.69 | 0.236721E+09 | 0.392818E+09 | 0.108482E+09 |
June | 0.272000E+09 | 41909203.44 | 0.230091E+09 | 0.426152E+09 | 50330085.64 |
July | 0.292452E+09 | 49359538.74 | 0.243092E+09 | 0.510139E+09 | 22866013.12 |
August | 0.391710E+09 | 0.144497E+09 | 0.247212E+09 | 0.654512E+09 | 32567645.11 |
September | 0.400025E+09 | 0.200846E+09 | 0.199179E+09 | 0.583469E+09 | 69967500.89 |
October | 0.584146E+09 | 0.366308E+09 | 0.217837E+09 | 0.756652E+09 | 0.148154E+09 |
November | 0.391434E+09 | 0.234810E+09 | 0.156624E+09 | 0.429050E+09 | 0.239603E+09 |
December | 0.401187E+09 | 0.284944E+09 | 0.116244E+09 | 0.417548E+09 | 0.319421E+09 |
Annual Sum or Average | 0.461662E+10 | 0.229767E+10 | 0.231894E+10 | 0.585714E+10 | 0.209728E+10 |
Minimum of Months | 0.272000E+09 | 41909203.44 | 0.116244E+09 | 0.369507E+09 | 22866013.12 |
Maximum of Months | 0.584146E+09 | 0.366308E+09 | 0.247212E+09 | 0.756652E+09 | 0.357778E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90475671.53 | 0.00 | 90475671.53 | 3424782.77 | 0.523655E+09 |
February | 0.111830E+09 | 0.00 | 0.111830E+09 | 8382172.66 | 0.479776E+09 |
March | 0.171737E+09 | 3577.06 | 0.171733E+09 | 57966995.61 | 0.338640E+09 |
April | 0.200004E+09 | 824110.29 | 0.199180E+09 | 0.128721E+09 | 0.218820E+09 |
May | 0.274881E+09 | 10059884.11 | 0.264822E+09 | 0.266508E+09 | 0.126769E+09 |
June | 0.280639E+09 | 14926733.97 | 0.265712E+09 | 0.347814E+09 | 61118965.08 |
July | 0.281470E+09 | 10985005.81 | 0.270485E+09 | 0.400337E+09 | 28403549.10 |
August | 0.248914E+09 | 3307307.95 | 0.245606E+09 | 0.349398E+09 | 43581393.66 |
September | 0.181379E+09 | 105444.69 | 0.181274E+09 | 0.196301E+09 | 97805645.92 |
October | 0.162070E+09 | 0.00 | 0.162070E+09 | 0.119260E+09 | 0.207057E+09 |
November | 0.110009E+09 | 0.00 | 0.110009E+09 | 29737998.85 | 0.335894E+09 |
December | 78918863.46 | 0.00 | 78918863.46 | 2340593.72 | 0.476070E+09 |
Annual Sum or Average | 0.219233E+10 | 40212063.88 | 0.215212E+10 | 0.191019E+10 | 0.293759E+10 |
Minimum of Months | 78918863.46 | 0.00 | 78918863.46 | 2340593.72 | 28403549.10 |
Maximum of Months | 0.281470E+09 | 14926733.97 | 0.270485E+09 | 0.400337E+09 | 0.523655E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 80948926.13 | 0.00 | 80948926.13 | 3064166.12 | 0.468495E+09 |
February | 0.100055E+09 | 0.00 | 0.100055E+09 | 7499561.64 | 0.429258E+09 |
March | 0.153654E+09 | 3200.41 | 0.153651E+09 | 51863290.61 | 0.302982E+09 |
April | 0.178944E+09 | 737334.60 | 0.178207E+09 | 0.115167E+09 | 0.195779E+09 |
May | 0.245937E+09 | 9000616.43 | 0.236937E+09 | 0.238446E+09 | 0.113421E+09 |
June | 0.251089E+09 | 13355005.44 | 0.237733E+09 | 0.311190E+09 | 54683369.63 |
July | 0.251832E+09 | 9828326.32 | 0.242004E+09 | 0.358183E+09 | 25412763.00 |
August | 0.222704E+09 | 2959060.95 | 0.219745E+09 | 0.312608E+09 | 38992438.04 |
September | 0.162281E+09 | 94341.77 | 0.162186E+09 | 0.175632E+09 | 87507081.99 |
October | 0.145004E+09 | 0.00 | 0.145004E+09 | 0.106702E+09 | 0.185255E+09 |
November | 98425591.88 | 0.00 | 98425591.88 | 26606700.25 | 0.300522E+09 |
December | 70609006.16 | 0.00 | 70609006.16 | 2094138.07 | 0.425877E+09 |
Annual Sum or Average | 0.196148E+10 | 35977885.91 | 0.192551E+10 | 0.170906E+10 | 0.262818E+10 |
Minimum of Months | 70609006.16 | 0.00 | 70609006.16 | 2094138.07 | 25412763.00 |
Maximum of Months | 0.251832E+09 | 13355005.44 | 0.242004E+09 | 0.358183E+09 | 0.468495E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.138631E+10 | 0.909713E+09 | 0.476595E+09 | 0.132549E+10 | 0.135287E+10 |
February | 0.165709E+10 | 0.110135E+10 | 0.555745E+09 | 0.162166E+10 | 0.119732E+10 |
March | 0.162549E+10 | 0.894811E+09 | 0.730681E+09 | 0.168454E+10 | 0.943353E+09 |
April | 0.125211E+10 | 0.506572E+09 | 0.745541E+09 | 0.136037E+10 | 0.649569E+09 |
May | 0.111126E+10 | 0.227513E+09 | 0.883750E+09 | 0.129164E+10 | 0.400822E+09 |
June | 0.101546E+10 | 0.156460E+09 | 0.858999E+09 | 0.135291E+10 | 0.191290E+09 |
July | 0.109181E+10 | 0.184274E+09 | 0.907535E+09 | 0.161175E+10 | 85662839.27 |
August | 0.146237E+10 | 0.539452E+09 | 0.922918E+09 | 0.215671E+10 | 0.132369E+09 |
September | 0.149341E+10 | 0.749819E+09 | 0.743594E+09 | 0.196475E+10 | 0.285921E+09 |
October | 0.218079E+10 | 0.136754E+10 | 0.813252E+09 | 0.266595E+10 | 0.580558E+09 |
November | 0.146134E+10 | 0.876615E+09 | 0.584725E+09 | 0.152773E+10 | 0.896399E+09 |
December | 0.149775E+10 | 0.106378E+10 | 0.433972E+09 | 0.150155E+10 | 0.120632E+10 |
Annual Sum or Average | 0.172352E+11 | 0.857789E+10 | 0.865731E+10 | 0.200651E+11 | 0.792246E+10 |
Minimum of Months | 0.101546E+10 | 0.156460E+09 | 0.433972E+09 | 0.129164E+10 | 85662839.27 |
Maximum of Months | 0.218079E+10 | 0.136754E+10 | 0.922918E+09 | 0.266595E+10 | 0.135287E+10 |
Report: WindowZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 679.60 | 627.85 | 701.21 | 460.14 | 241.07 | 0.00 | 0.00 |
February | 916.07 | 621.23 | 927.98 | 616.76 | 311.22 | 0.00 | 0.00 |
March | 859.05 | 441.64 | 822.19 | 452.60 | 369.58 | 0.00 | 0.00 |
April | 720.61 | 311.18 | 654.44 | 264.77 | 389.67 | 0.00 | 0.00 |
May | 670.77 | 178.61 | 562.08 | 115.08 | 447.01 | 0.00 | 0.00 |
June | 721.13 | 85.70 | 530.75 | 81.78 | 448.97 | 0.00 | 0.00 |
July | 820.57 | 36.90 | 552.24 | 93.21 | 459.04 | 0.00 | 0.00 |
August | 1086.32 | 64.97 | 739.68 | 272.86 | 466.82 | 0.00 | 0.00 |
September | 1029.02 | 137.01 | 780.56 | 391.91 | 388.65 | 0.00 | 0.00 |
October | 1343.67 | 282.19 | 1103.06 | 691.71 | 411.35 | 0.00 | 0.00 |
November | 801.95 | 436.38 | 763.80 | 458.18 | 305.62 | 0.00 | 0.00 |
December | 763.09 | 564.69 | 757.58 | 538.07 | 219.51 | 0.00 | 0.00 |
Annual Sum or Average | 867.80 | 313.98 | 740.41 | 368.50 | 371.91 | 0.00 | 0.00 |
Minimum of Months | 670.77 | 36.90 | 530.75 | 81.78 | 219.51 | 0.00 | 0.00 |
Maximum of Months | 1343.67 | 627.85 | 1103.06 | 691.71 | 466.82 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1890.77 | 1822.60 | 1974.55 | 1295.73 | 678.82 | 0.00 | 0.00 |
February | 2547.67 | 1808.21 | 2613.12 | 1736.75 | 876.37 | 0.00 | 0.00 |
March | 2386.24 | 1325.27 | 2315.23 | 1274.50 | 1040.72 | 0.00 | 0.00 |
April | 1992.38 | 952.97 | 1842.86 | 745.58 | 1097.28 | 0.00 | 0.00 |
May | 1838.35 | 572.49 | 1582.79 | 324.05 | 1258.74 | 0.00 | 0.00 |
June | 1992.65 | 283.86 | 1494.54 | 230.28 | 1264.27 | 0.00 | 0.00 |
July | 2281.11 | 128.38 | 1555.08 | 262.47 | 1292.62 | 0.00 | 0.00 |
August | 3034.84 | 204.25 | 2082.88 | 768.36 | 1314.52 | 0.00 | 0.00 |
September | 2864.23 | 442.71 | 2198.00 | 1103.59 | 1094.42 | 0.00 | 0.00 |
October | 3746.46 | 872.22 | 3106.15 | 1947.82 | 1158.33 | 0.00 | 0.00 |
November | 2221.95 | 1309.40 | 2150.80 | 1290.21 | 860.60 | 0.00 | 0.00 |
December | 2122.91 | 1658.03 | 2133.29 | 1515.17 | 618.12 | 0.00 | 0.00 |
Annual Sum or Average | 2410.39 | 943.50 | 2084.94 | 1037.67 | 1047.27 | 0.00 | 0.00 |
Minimum of Months | 1838.35 | 128.38 | 1494.54 | 230.28 | 618.12 | 0.00 | 0.00 |
Maximum of Months | 3746.46 | 1822.60 | 3106.15 | 1947.82 | 1314.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2496.08 | 2487.71 | 2565.06 | 1683.23 | 881.83 | 0.00 | 0.00 |
February | 3372.45 | 2449.35 | 3394.59 | 2256.14 | 1138.45 | 0.00 | 0.00 |
March | 3157.90 | 1805.36 | 3007.61 | 1655.65 | 1351.96 | 0.00 | 0.00 |
April | 2633.62 | 1308.44 | 2393.98 | 968.55 | 1425.43 | 0.00 | 0.00 |
May | 2426.84 | 788.81 | 2056.14 | 420.96 | 1635.17 | 0.00 | 0.00 |
June | 2639.55 | 382.51 | 1941.50 | 299.14 | 1642.35 | 0.00 | 0.00 |
July | 3031.05 | 168.59 | 2020.14 | 340.96 | 1679.18 | 0.00 | 0.00 |
August | 4030.56 | 263.05 | 2705.78 | 998.14 | 1707.64 | 0.00 | 0.00 |
September | 3788.10 | 592.08 | 2855.33 | 1433.62 | 1421.71 | 0.00 | 0.00 |
October | 4957.12 | 1160.34 | 4035.07 | 2530.33 | 1504.74 | 0.00 | 0.00 |
November | 2929.67 | 1793.22 | 2794.02 | 1676.05 | 1117.96 | 0.00 | 0.00 |
December | 2800.32 | 2267.42 | 2771.26 | 1968.29 | 802.97 | 0.00 | 0.00 |
Annual Sum or Average | 3189.19 | 1282.33 | 2708.45 | 1347.99 | 1360.46 | 0.00 | 0.00 |
Minimum of Months | 2426.84 | 168.59 | 1941.50 | 299.14 | 802.97 | 0.00 | 0.00 |
Maximum of Months | 4957.12 | 2487.71 | 4035.07 | 2530.33 | 1707.64 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 186.17 | 366.37 | 241.68 | 133.28 | 108.40 | 0.00 | 0.00 |
February | 268.89 | 363.80 | 334.84 | 188.37 | 146.47 | 0.00 | 0.00 |
March | 364.98 | 248.76 | 387.39 | 193.68 | 193.71 | 0.00 | 0.00 |
April | 390.83 | 173.39 | 373.58 | 156.70 | 216.88 | 0.00 | 0.00 |
May | 465.96 | 96.85 | 396.40 | 131.19 | 265.20 | 0.00 | 0.00 |
June | 558.73 | 37.63 | 416.61 | 141.95 | 274.66 | 0.00 | 0.00 |
July | 590.20 | 9.66 | 400.78 | 128.01 | 272.78 | 0.00 | 0.00 |
August | 682.82 | 22.88 | 468.86 | 203.11 | 265.75 | 0.00 | 0.00 |
September | 498.79 | 64.69 | 383.87 | 177.69 | 206.17 | 0.00 | 0.00 |
October | 521.87 | 151.29 | 445.84 | 247.71 | 198.14 | 0.00 | 0.00 |
November | 228.88 | 250.29 | 258.27 | 121.92 | 136.35 | 0.00 | 0.00 |
December | 199.13 | 328.33 | 244.52 | 147.28 | 97.24 | 0.00 | 0.00 |
Annual Sum or Average | 414.22 | 175.11 | 363.00 | 164.20 | 198.80 | 0.00 | 0.00 |
Minimum of Months | 186.17 | 9.66 | 241.68 | 121.92 | 97.24 | 0.00 | 0.00 |
Maximum of Months | 682.82 | 366.37 | 468.86 | 247.71 | 274.66 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 62.46 | 384.70 | 129.71 | 42.30 | 87.41 | 0.00 | 0.00 |
February | 104.05 | 386.99 | 187.86 | 66.43 | 121.44 | 0.00 | 0.00 |
March | 219.62 | 249.66 | 275.46 | 104.19 | 171.27 | 0.00 | 0.00 |
April | 293.79 | 171.65 | 305.11 | 104.60 | 200.51 | 0.00 | 0.00 |
May | 417.35 | 94.20 | 366.30 | 111.40 | 254.89 | 0.00 | 0.00 |
June | 525.71 | 36.53 | 397.16 | 130.33 | 266.83 | 0.00 | 0.00 |
July | 547.97 | 9.38 | 374.57 | 112.82 | 261.76 | 0.00 | 0.00 |
August | 572.81 | 22.01 | 396.00 | 150.14 | 245.86 | 0.00 | 0.00 |
September | 359.47 | 63.45 | 284.79 | 100.24 | 184.55 | 0.00 | 0.00 |
October | 297.78 | 150.14 | 275.53 | 110.94 | 164.58 | 0.00 | 0.00 |
November | 87.20 | 256.55 | 140.77 | 31.33 | 109.43 | 0.00 | 0.00 |
December | 58.74 | 346.43 | 118.00 | 40.89 | 77.11 | 0.00 | 0.00 |
Annual Sum or Average | 296.92 | 179.82 | 271.50 | 92.35 | 179.15 | 0.00 | 0.00 |
Minimum of Months | 58.74 | 9.38 | 118.00 | 31.33 | 77.11 | 0.00 | 0.00 |
Maximum of Months | 572.81 | 386.99 | 397.16 | 150.14 | 266.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 107.99 | 97.62 | 110.89 | 72.77 | 38.12 | 0.00 | 0.00 |
February | 144.36 | 100.62 | 146.75 | 97.54 | 49.22 | 0.00 | 0.00 |
March | 135.04 | 73.71 | 130.02 | 71.58 | 58.45 | 0.00 | 0.00 |
April | 112.77 | 52.83 | 103.50 | 41.87 | 61.62 | 0.00 | 0.00 |
May | 103.50 | 32.23 | 88.89 | 18.20 | 70.69 | 0.00 | 0.00 |
June | 114.17 | 14.53 | 83.93 | 12.93 | 71.00 | 0.00 | 0.00 |
July | 132.30 | 5.44 | 87.33 | 14.74 | 72.59 | 0.00 | 0.00 |
August | 175.56 | 9.45 | 116.97 | 43.15 | 73.82 | 0.00 | 0.00 |
September | 163.16 | 23.54 | 123.44 | 61.98 | 61.46 | 0.00 | 0.00 |
October | 211.81 | 49.24 | 174.44 | 109.39 | 65.05 | 0.00 | 0.00 |
November | 125.74 | 72.78 | 120.79 | 72.46 | 48.33 | 0.00 | 0.00 |
December | 120.68 | 89.93 | 119.81 | 85.09 | 34.71 | 0.00 | 0.00 |
Annual Sum or Average | 137.29 | 51.55 | 117.09 | 58.28 | 58.81 | 0.00 | 0.00 |
Minimum of Months | 103.50 | 5.44 | 83.93 | 12.93 | 34.71 | 0.00 | 0.00 |
Maximum of Months | 211.81 | 100.62 | 174.44 | 109.39 | 73.82 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1.41 | 116.81 | 21.34 | 0.00 | 21.34 | 0.00 | 0.00 |
February | 3.15 | 118.05 | 29.20 | 0.00 | 29.20 | 0.00 | 0.00 |
March | 16.20 | 75.12 | 40.51 | 0.00 | 40.51 | 0.00 | 0.00 |
April | 34.67 | 49.10 | 48.75 | 0.20 | 48.55 | 0.00 | 0.00 |
May | 68.59 | 25.23 | 64.84 | 2.37 | 62.47 | 0.00 | 0.00 |
June | 93.94 | 8.77 | 68.40 | 3.64 | 64.76 | 0.00 | 0.00 |
July | 106.14 | 1.80 | 66.39 | 2.59 | 63.80 | 0.00 | 0.00 |
August | 94.15 | 4.89 | 58.71 | 0.78 | 57.93 | 0.00 | 0.00 |
September | 55.13 | 16.44 | 44.21 | 0.03 | 44.18 | 0.00 | 0.00 |
October | 33.02 | 41.78 | 38.23 | 0.00 | 38.23 | 0.00 | 0.00 |
November | 8.92 | 76.61 | 26.81 | 0.00 | 26.81 | 0.00 | 0.00 |
December | 0.98 | 105.54 | 18.62 | 0.00 | 18.62 | 0.00 | 0.00 |
Annual Sum or Average | 43.30 | 52.98 | 43.92 | 0.81 | 43.11 | 0.00 | 0.00 |
Minimum of Months | 0.98 | 1.80 | 18.62 | 0.00 | 18.62 | 0.00 | 0.00 |
Maximum of Months | 106.14 | 118.05 | 68.40 | 3.64 | 64.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 186.91 | 364.06 | 242.40 | 132.43 | 109.97 | 0.00 | 0.00 |
February | 279.85 | 359.11 | 344.58 | 196.96 | 147.61 | 0.00 | 0.00 |
March | 343.99 | 250.16 | 369.44 | 177.41 | 192.03 | 0.00 | 0.00 |
April | 390.85 | 168.98 | 377.04 | 161.05 | 216.00 | 0.00 | 0.00 |
May | 481.33 | 94.09 | 410.12 | 141.90 | 268.22 | 0.00 | 0.00 |
June | 513.74 | 35.89 | 382.57 | 116.73 | 265.84 | 0.00 | 0.00 |
July | 573.73 | 9.08 | 387.67 | 118.68 | 268.98 | 0.00 | 0.00 |
August | 670.73 | 21.47 | 460.40 | 195.68 | 264.72 | 0.00 | 0.00 |
September | 504.09 | 62.42 | 389.33 | 183.35 | 205.98 | 0.00 | 0.00 |
October | 500.36 | 148.17 | 430.40 | 232.86 | 197.53 | 0.00 | 0.00 |
November | 260.04 | 248.08 | 282.51 | 141.12 | 141.39 | 0.00 | 0.00 |
December | 209.23 | 324.80 | 252.59 | 154.89 | 97.70 | 0.00 | 0.00 |
Annual Sum or Average | 410.55 | 172.83 | 360.92 | 162.61 | 198.31 | 0.00 | 0.00 |
Minimum of Months | 186.91 | 9.08 | 242.40 | 116.73 | 97.70 | 0.00 | 0.00 |
Maximum of Months | 670.73 | 364.06 | 460.40 | 232.86 | 268.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 58.26 | 377.53 | 130.44 | 41.46 | 88.98 | 0.00 | 0.00 |
February | 104.68 | 371.56 | 197.60 | 75.02 | 122.58 | 0.00 | 0.00 |
March | 197.70 | 249.93 | 257.51 | 87.92 | 169.58 | 0.00 | 0.00 |
April | 292.87 | 166.87 | 308.58 | 108.95 | 199.63 | 0.00 | 0.00 |
May | 432.93 | 92.10 | 380.02 | 122.12 | 257.91 | 0.00 | 0.00 |
June | 480.99 | 35.17 | 363.12 | 105.11 | 258.02 | 0.00 | 0.00 |
July | 531.56 | 8.92 | 361.46 | 103.49 | 257.96 | 0.00 | 0.00 |
August | 560.69 | 20.83 | 387.54 | 142.71 | 244.83 | 0.00 | 0.00 |
September | 363.81 | 60.89 | 290.26 | 105.90 | 184.36 | 0.00 | 0.00 |
October | 274.97 | 146.12 | 260.08 | 96.10 | 163.98 | 0.00 | 0.00 |
November | 114.51 | 250.31 | 165.01 | 50.53 | 114.48 | 0.00 | 0.00 |
December | 63.18 | 336.90 | 126.07 | 48.51 | 77.56 | 0.00 | 0.00 |
Annual Sum or Average | 290.94 | 175.35 | 269.42 | 90.76 | 178.66 | 0.00 | 0.00 |
Minimum of Months | 58.26 | 8.92 | 126.07 | 41.46 | 77.56 | 0.00 | 0.00 |
Maximum of Months | 560.69 | 377.53 | 387.54 | 142.71 | 258.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 212.85 | 471.13 | 286.50 | 157.67 | 128.83 | 0.00 | 0.00 |
February | 294.89 | 466.29 | 381.24 | 211.33 | 169.91 | 0.00 | 0.00 |
March | 326.06 | 325.93 | 369.48 | 155.09 | 214.39 | 0.00 | 0.00 |
April | 320.46 | 227.31 | 329.85 | 91.16 | 238.69 | 0.00 | 0.00 |
May | 370.27 | 128.66 | 333.06 | 44.57 | 288.49 | 0.00 | 0.00 |
June | 438.50 | 61.28 | 330.05 | 35.90 | 294.14 | 0.00 | 0.00 |
July | 497.51 | 25.08 | 333.06 | 37.55 | 295.51 | 0.00 | 0.00 |
August | 564.11 | 42.57 | 380.64 | 95.19 | 285.46 | 0.00 | 0.00 |
September | 464.77 | 99.78 | 363.23 | 134.34 | 228.89 | 0.00 | 0.00 |
October | 527.67 | 205.01 | 460.78 | 237.02 | 223.77 | 0.00 | 0.00 |
November | 284.49 | 323.50 | 319.80 | 157.00 | 162.81 | 0.00 | 0.00 |
December | 241.94 | 420.37 | 299.91 | 184.37 | 115.54 | 0.00 | 0.00 |
Annual Sum or Average | 379.33 | 231.76 | 348.85 | 128.01 | 220.84 | 0.00 | 0.00 |
Minimum of Months | 212.85 | 25.08 | 286.50 | 35.90 | 115.54 | 0.00 | 0.00 |
Maximum of Months | 564.11 | 471.13 | 460.78 | 237.02 | 295.51 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 185.80 | 364.50 | 241.68 | 133.28 | 108.40 | 0.00 | 0.00 |
February | 267.77 | 362.50 | 334.84 | 188.37 | 146.47 | 0.00 | 0.00 |
March | 362.75 | 247.29 | 387.39 | 193.68 | 193.71 | 0.00 | 0.00 |
April | 388.23 | 171.79 | 373.58 | 156.70 | 216.88 | 0.00 | 0.00 |
May | 462.31 | 95.61 | 396.40 | 131.19 | 265.20 | 0.00 | 0.00 |
June | 554.94 | 36.38 | 416.61 | 141.95 | 274.66 | 0.00 | 0.00 |
July | 587.14 | 8.82 | 400.78 | 128.01 | 272.78 | 0.00 | 0.00 |
August | 679.79 | 21.62 | 468.86 | 203.11 | 265.75 | 0.00 | 0.00 |
September | 496.29 | 62.71 | 383.87 | 177.69 | 206.17 | 0.00 | 0.00 |
October | 519.46 | 148.62 | 445.84 | 247.71 | 198.14 | 0.00 | 0.00 |
November | 228.87 | 247.45 | 258.27 | 121.92 | 136.35 | 0.00 | 0.00 |
December | 199.14 | 325.98 | 244.52 | 147.28 | 97.24 | 0.00 | 0.00 |
Annual Sum or Average | 412.15 | 173.39 | 363.00 | 164.20 | 198.80 | 0.00 | 0.00 |
Minimum of Months | 185.80 | 8.82 | 241.68 | 121.92 | 97.24 | 0.00 | 0.00 |
Maximum of Months | 679.79 | 364.50 | 468.86 | 247.71 | 274.66 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 62.55 | 383.01 | 129.71 | 42.30 | 87.41 | 0.00 | 0.00 |
February | 103.76 | 386.04 | 187.86 | 66.43 | 121.44 | 0.00 | 0.00 |
March | 218.77 | 247.95 | 275.46 | 104.19 | 171.27 | 0.00 | 0.00 |
April | 292.30 | 169.82 | 305.11 | 104.60 | 200.51 | 0.00 | 0.00 |
May | 414.24 | 92.99 | 366.30 | 111.40 | 254.89 | 0.00 | 0.00 |
June | 522.36 | 35.34 | 397.16 | 130.33 | 266.83 | 0.00 | 0.00 |
July | 545.31 | 8.59 | 374.57 | 112.82 | 261.76 | 0.00 | 0.00 |
August | 570.71 | 20.75 | 396.00 | 150.14 | 245.86 | 0.00 | 0.00 |
September | 358.10 | 61.31 | 284.79 | 100.24 | 184.55 | 0.00 | 0.00 |
October | 297.58 | 146.70 | 275.53 | 110.94 | 164.58 | 0.00 | 0.00 |
November | 88.04 | 253.29 | 140.77 | 31.33 | 109.43 | 0.00 | 0.00 |
December | 59.20 | 343.92 | 118.00 | 40.89 | 77.11 | 0.00 | 0.00 |
Annual Sum or Average | 295.75 | 177.98 | 271.50 | 92.35 | 179.15 | 0.00 | 0.00 |
Minimum of Months | 59.20 | 8.59 | 118.00 | 31.33 | 77.11 | 0.00 | 0.00 |
Maximum of Months | 570.71 | 386.04 | 397.16 | 150.14 | 266.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 192.02 | 190.09 | 203.33 | 133.43 | 69.90 | 0.00 | 0.00 |
February | 258.94 | 189.12 | 269.09 | 178.84 | 90.24 | 0.00 | 0.00 |
March | 243.99 | 132.95 | 238.41 | 131.24 | 107.17 | 0.00 | 0.00 |
April | 205.69 | 91.38 | 189.77 | 76.78 | 112.99 | 0.00 | 0.00 |
May | 192.84 | 49.74 | 162.99 | 33.37 | 129.62 | 0.00 | 0.00 |
June | 214.50 | 17.71 | 153.90 | 23.71 | 130.19 | 0.00 | 0.00 |
July | 250.38 | 3.82 | 160.14 | 27.03 | 133.11 | 0.00 | 0.00 |
August | 328.05 | 10.27 | 214.49 | 79.12 | 135.36 | 0.00 | 0.00 |
September | 301.81 | 32.18 | 226.34 | 113.64 | 112.70 | 0.00 | 0.00 |
October | 388.68 | 77.40 | 319.86 | 200.58 | 119.28 | 0.00 | 0.00 |
November | 228.58 | 130.87 | 221.48 | 132.86 | 88.62 | 0.00 | 0.00 |
December | 216.95 | 170.16 | 219.68 | 156.02 | 63.65 | 0.00 | 0.00 |
Annual Sum or Average | 251.97 | 90.76 | 214.70 | 106.85 | 107.84 | 0.00 | 0.00 |
Minimum of Months | 192.02 | 3.82 | 153.90 | 23.71 | 63.65 | 0.00 | 0.00 |
Maximum of Months | 388.68 | 190.09 | 319.86 | 200.58 | 135.36 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4.17 | 1177.81 | 186.70 | 0.00 | 186.70 | 0.00 | 0.00 |
February | 14.31 | 1187.26 | 255.50 | 0.00 | 255.50 | 0.00 | 0.00 |
March | 103.09 | 790.65 | 354.39 | 0.01 | 354.39 | 0.00 | 0.00 |
April | 247.09 | 535.30 | 426.48 | 1.76 | 424.73 | 0.00 | 0.00 |
May | 516.90 | 292.65 | 567.24 | 20.76 | 546.48 | 0.00 | 0.00 |
June | 732.39 | 138.24 | 598.43 | 31.83 | 566.60 | 0.00 | 0.00 |
July | 828.77 | 58.71 | 580.84 | 22.67 | 558.17 | 0.00 | 0.00 |
August | 726.66 | 89.70 | 513.65 | 6.82 | 506.83 | 0.00 | 0.00 |
September | 411.55 | 226.48 | 386.77 | 0.22 | 386.54 | 0.00 | 0.00 |
October | 235.00 | 468.51 | 334.44 | 0.00 | 334.44 | 0.00 | 0.00 |
November | 52.01 | 811.03 | 234.58 | 0.00 | 234.58 | 0.00 | 0.00 |
December | 2.97 | 1087.28 | 162.86 | 0.00 | 162.86 | 0.00 | 0.00 |
Annual Sum or Average | 325.03 | 568.49 | 384.23 | 7.05 | 377.19 | 0.00 | 0.00 |
Minimum of Months | 2.97 | 58.71 | 162.86 | 0.00 | 162.86 | 0.00 | 0.00 |
Maximum of Months | 828.77 | 1187.26 | 598.43 | 31.83 | 566.60 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2.83 | 1212.98 | 186.70 | 0.00 | 186.70 | 0.00 | 0.00 |
February | 12.06 | 1220.76 | 255.50 | 0.00 | 255.50 | 0.00 | 0.00 |
March | 95.36 | 813.89 | 354.39 | 0.01 | 354.39 | 0.00 | 0.00 |
April | 236.39 | 551.55 | 426.48 | 1.76 | 424.73 | 0.00 | 0.00 |
May | 505.08 | 300.96 | 567.24 | 20.76 | 546.48 | 0.00 | 0.00 |
June | 723.60 | 143.67 | 598.43 | 31.83 | 566.60 | 0.00 | 0.00 |
July | 821.04 | 62.77 | 580.84 | 22.67 | 558.17 | 0.00 | 0.00 |
August | 718.70 | 93.95 | 513.65 | 6.82 | 506.83 | 0.00 | 0.00 |
September | 403.51 | 234.72 | 386.77 | 0.22 | 386.54 | 0.00 | 0.00 |
October | 226.51 | 481.41 | 334.44 | 0.00 | 334.44 | 0.00 | 0.00 |
November | 47.12 | 837.28 | 234.58 | 0.00 | 234.58 | 0.00 | 0.00 |
December | 2.17 | 1120.23 | 162.86 | 0.00 | 162.86 | 0.00 | 0.00 |
Annual Sum or Average | 318.30 | 585.95 | 384.23 | 7.05 | 377.19 | 0.00 | 0.00 |
Minimum of Months | 2.17 | 62.77 | 162.86 | 0.00 | 162.86 | 0.00 | 0.00 |
Maximum of Months | 821.04 | 1220.76 | 598.43 | 31.83 | 566.60 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 243.32 | 784.71 | 372.82 | 173.88 | 198.94 | 0.00 | 0.00 |
February | 387.58 | 764.94 | 542.15 | 271.97 | 270.18 | 0.00 | 0.00 |
March | 568.54 | 547.02 | 626.92 | 265.32 | 361.60 | 0.00 | 0.00 |
April | 740.23 | 378.94 | 685.59 | 269.98 | 415.61 | 0.00 | 0.00 |
May | 1002.90 | 223.11 | 790.10 | 264.00 | 526.10 | 0.00 | 0.00 |
June | 1107.25 | 107.38 | 745.66 | 221.82 | 523.83 | 0.00 | 0.00 |
July | 1229.54 | 48.27 | 749.08 | 222.16 | 526.92 | 0.00 | 0.00 |
August | 1354.36 | 69.11 | 847.89 | 338.37 | 509.52 | 0.00 | 0.00 |
September | 969.96 | 153.24 | 679.55 | 289.24 | 390.32 | 0.00 | 0.00 |
October | 845.52 | 316.10 | 690.45 | 328.95 | 361.50 | 0.00 | 0.00 |
November | 394.90 | 538.34 | 447.50 | 191.64 | 255.85 | 0.00 | 0.00 |
December | 274.01 | 701.87 | 378.64 | 203.39 | 175.25 | 0.00 | 0.00 |
Annual Sum or Average | 762.43 | 383.98 | 630.31 | 253.35 | 376.95 | 0.00 | 0.00 |
Minimum of Months | 243.32 | 48.27 | 372.82 | 173.88 | 175.25 | 0.00 | 0.00 |
Maximum of Months | 1354.36 | 784.71 | 847.89 | 338.37 | 526.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 463.21 | 841.43 | 581.59 | 339.65 | 241.94 | 0.00 | 0.00 |
February | 636.59 | 830.37 | 772.56 | 455.25 | 317.31 | 0.00 | 0.00 |
March | 663.84 | 585.66 | 728.38 | 334.09 | 394.29 | 0.00 | 0.00 |
April | 618.11 | 409.75 | 629.27 | 196.04 | 433.23 | 0.00 | 0.00 |
May | 667.37 | 235.93 | 609.35 | 92.06 | 517.29 | 0.00 | 0.00 |
June | 774.23 | 116.51 | 596.91 | 71.27 | 525.63 | 0.00 | 0.00 |
July | 884.41 | 51.53 | 606.75 | 76.57 | 530.18 | 0.00 | 0.00 |
August | 1052.04 | 79.90 | 722.07 | 203.75 | 518.32 | 0.00 | 0.00 |
September | 901.07 | 181.37 | 708.75 | 289.36 | 419.39 | 0.00 | 0.00 |
October | 1075.57 | 359.08 | 928.86 | 510.58 | 418.28 | 0.00 | 0.00 |
November | 596.00 | 576.22 | 644.20 | 338.20 | 306.00 | 0.00 | 0.00 |
December | 526.51 | 751.38 | 615.02 | 397.17 | 217.85 | 0.00 | 0.00 |
Annual Sum or Average | 739.26 | 415.94 | 678.24 | 274.42 | 403.82 | 0.00 | 0.00 |
Minimum of Months | 463.21 | 51.53 | 581.59 | 71.27 | 217.85 | 0.00 | 0.00 |
Maximum of Months | 1075.57 | 841.43 | 928.86 | 510.58 | 530.18 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.182023E+10 | 0.168163E+10 | 0.187811E+10 | 0.123244E+10 | 0.645669E+09 | 0.00 | 0.00 |
February | 0.221617E+10 | 0.150288E+10 | 0.224496E+10 | 0.149206E+10 | 0.752897E+09 | 0.00 | 0.00 |
March | 0.230088E+10 | 0.118290E+10 | 0.220215E+10 | 0.121226E+10 | 0.989890E+09 | 0.00 | 0.00 |
April | 0.186783E+10 | 0.806577E+09 | 0.169631E+10 | 0.686285E+09 | 0.101002E+10 | 0.00 | 0.00 |
May | 0.179658E+10 | 0.478379E+09 | 0.150549E+10 | 0.308226E+09 | 0.119726E+10 | 0.00 | 0.00 |
June | 0.186916E+10 | 0.222137E+09 | 0.137569E+10 | 0.211965E+09 | 0.116373E+10 | 0.00 | 0.00 |
July | 0.219781E+10 | 98823119.18 | 0.147913E+10 | 0.249647E+09 | 0.122948E+10 | 0.00 | 0.00 |
August | 0.290961E+10 | 0.174012E+09 | 0.198115E+10 | 0.730828E+09 | 0.125032E+10 | 0.00 | 0.00 |
September | 0.266721E+10 | 0.355119E+09 | 0.202321E+10 | 0.101583E+10 | 0.100738E+10 | 0.00 | 0.00 |
October | 0.359887E+10 | 0.755806E+09 | 0.295444E+10 | 0.185269E+10 | 0.110176E+10 | 0.00 | 0.00 |
November | 0.207865E+10 | 0.113109E+10 | 0.197976E+10 | 0.118761E+10 | 0.792159E+09 | 0.00 | 0.00 |
December | 0.204387E+10 | 0.151246E+10 | 0.202909E+10 | 0.144117E+10 | 0.587926E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.273669E+11 | 0.990181E+10 | 0.233495E+11 | 0.116210E+11 | 0.117285E+11 | 0.00 | 0.00 |
Minimum of Months | 0.179658E+10 | 98823119.18 | 0.137569E+10 | 0.211965E+09 | 0.587926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.359887E+10 | 0.168163E+10 | 0.295444E+10 | 0.185269E+10 | 0.125032E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.506423E+10 | 0.488166E+10 | 0.528864E+10 | 0.347048E+10 | 0.181816E+10 | 0.00 | 0.00 |
February | 0.616332E+10 | 0.437443E+10 | 0.632166E+10 | 0.420155E+10 | 0.212011E+10 | 0.00 | 0.00 |
March | 0.639130E+10 | 0.354960E+10 | 0.620110E+10 | 0.341363E+10 | 0.278747E+10 | 0.00 | 0.00 |
April | 0.516424E+10 | 0.247010E+10 | 0.477669E+10 | 0.193253E+10 | 0.284415E+10 | 0.00 | 0.00 |
May | 0.492384E+10 | 0.153335E+10 | 0.423935E+10 | 0.867945E+09 | 0.337140E+10 | 0.00 | 0.00 |
June | 0.516495E+10 | 0.735757E+09 | 0.387386E+10 | 0.596881E+09 | 0.327698E+10 | 0.00 | 0.00 |
July | 0.610973E+10 | 0.343841E+09 | 0.416513E+10 | 0.702990E+09 | 0.346214E+10 | 0.00 | 0.00 |
August | 0.812851E+10 | 0.547074E+09 | 0.557879E+10 | 0.205796E+10 | 0.352082E+10 | 0.00 | 0.00 |
September | 0.742407E+10 | 0.114749E+10 | 0.569723E+10 | 0.286050E+10 | 0.283673E+10 | 0.00 | 0.00 |
October | 0.100345E+11 | 0.233615E+10 | 0.831952E+10 | 0.521704E+10 | 0.310247E+10 | 0.00 | 0.00 |
November | 0.575928E+10 | 0.339396E+10 | 0.557489E+10 | 0.334422E+10 | 0.223067E+10 | 0.00 | 0.00 |
December | 0.568600E+10 | 0.444087E+10 | 0.571380E+10 | 0.405823E+10 | 0.165556E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.760140E+11 | 0.297543E+11 | 0.657506E+11 | 0.327240E+11 | 0.330267E+11 | 0.00 | 0.00 |
Minimum of Months | 0.492384E+10 | 0.343841E+09 | 0.387386E+10 | 0.596881E+09 | 0.165556E+10 | 0.00 | 0.00 |
Maximum of Months | 0.100345E+11 | 0.488166E+10 | 0.831952E+10 | 0.521704E+10 | 0.352082E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.668550E+10 | 0.666308E+10 | 0.687025E+10 | 0.450835E+10 | 0.236190E+10 | 0.00 | 0.00 |
February | 0.815862E+10 | 0.592547E+10 | 0.821220E+10 | 0.545806E+10 | 0.275414E+10 | 0.00 | 0.00 |
March | 0.845812E+10 | 0.483547E+10 | 0.805558E+10 | 0.443450E+10 | 0.362108E+10 | 0.00 | 0.00 |
April | 0.682635E+10 | 0.339148E+10 | 0.620519E+10 | 0.251047E+10 | 0.369472E+10 | 0.00 | 0.00 |
May | 0.650006E+10 | 0.211276E+10 | 0.550715E+10 | 0.112751E+10 | 0.437965E+10 | 0.00 | 0.00 |
June | 0.684172E+10 | 0.991455E+09 | 0.503236E+10 | 0.775382E+09 | 0.425698E+10 | 0.00 | 0.00 |
July | 0.811838E+10 | 0.451539E+09 | 0.541074E+10 | 0.913224E+09 | 0.449752E+10 | 0.00 | 0.00 |
August | 0.107954E+11 | 0.704559E+09 | 0.724716E+10 | 0.267341E+10 | 0.457375E+10 | 0.00 | 0.00 |
September | 0.981876E+10 | 0.153466E+10 | 0.740102E+10 | 0.371595E+10 | 0.368507E+10 | 0.00 | 0.00 |
October | 0.132772E+11 | 0.310787E+10 | 0.108075E+11 | 0.677724E+10 | 0.403029E+10 | 0.00 | 0.00 |
November | 0.759371E+10 | 0.464802E+10 | 0.724209E+10 | 0.434433E+10 | 0.289776E+10 | 0.00 | 0.00 |
December | 0.750037E+10 | 0.607307E+10 | 0.742255E+10 | 0.527188E+10 | 0.215067E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.100574E+12 | 0.404394E+11 | 0.854138E+11 | 0.425103E+11 | 0.429035E+11 | 0.00 | 0.00 |
Minimum of Months | 0.650006E+10 | 0.451539E+09 | 0.503236E+10 | 0.775382E+09 | 0.215067E+10 | 0.00 | 0.00 |
Maximum of Months | 0.132772E+11 | 0.666308E+10 | 0.108075E+11 | 0.677724E+10 | 0.457375E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.498635E+09 | 0.981280E+09 | 0.647322E+09 | 0.356975E+09 | 0.290347E+09 | 0.00 | 0.00 |
February | 0.650507E+09 | 0.880105E+09 | 0.810044E+09 | 0.455710E+09 | 0.354334E+09 | 0.00 | 0.00 |
March | 0.977554E+09 | 0.666291E+09 | 0.103759E+10 | 0.518749E+09 | 0.518839E+09 | 0.00 | 0.00 |
April | 0.101304E+10 | 0.449425E+09 | 0.968321E+09 | 0.406169E+09 | 0.562152E+09 | 0.00 | 0.00 |
May | 0.124803E+10 | 0.259413E+09 | 0.106171E+10 | 0.351385E+09 | 0.710324E+09 | 0.00 | 0.00 |
June | 0.144823E+10 | 97547647.86 | 0.107985E+10 | 0.367935E+09 | 0.711915E+09 | 0.00 | 0.00 |
July | 0.158078E+10 | 25863032.79 | 0.107346E+10 | 0.342851E+09 | 0.730606E+09 | 0.00 | 0.00 |
August | 0.182887E+10 | 61284980.56 | 0.125580E+10 | 0.544016E+09 | 0.711787E+09 | 0.00 | 0.00 |
September | 0.129287E+10 | 0.167667E+09 | 0.994979E+09 | 0.460585E+09 | 0.534394E+09 | 0.00 | 0.00 |
October | 0.139778E+10 | 0.405208E+09 | 0.119415E+10 | 0.663463E+09 | 0.530687E+09 | 0.00 | 0.00 |
November | 0.593266E+09 | 0.648764E+09 | 0.669436E+09 | 0.316026E+09 | 0.353410E+09 | 0.00 | 0.00 |
December | 0.533354E+09 | 0.879407E+09 | 0.654927E+09 | 0.394476E+09 | 0.260452E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.130629E+11 | 0.552226E+10 | 0.114476E+11 | 0.517834E+10 | 0.626925E+10 | 0.00 | 0.00 |
Minimum of Months | 0.498635E+09 | 25863032.79 | 0.647322E+09 | 0.316026E+09 | 0.260452E+09 | 0.00 | 0.00 |
Maximum of Months | 0.182887E+10 | 0.981280E+09 | 0.125580E+10 | 0.663463E+09 | 0.730606E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.167304E+09 | 0.103037E+10 | 0.347427E+09 | 0.113300E+09 | 0.234127E+09 | 0.00 | 0.00 |
February | 0.251715E+09 | 0.936198E+09 | 0.454479E+09 | 0.160704E+09 | 0.293776E+09 | 0.00 | 0.00 |
March | 0.588240E+09 | 0.668684E+09 | 0.737791E+09 | 0.279068E+09 | 0.458722E+09 | 0.00 | 0.00 |
April | 0.761514E+09 | 0.444924E+09 | 0.790856E+09 | 0.271129E+09 | 0.519727E+09 | 0.00 | 0.00 |
May | 0.111783E+10 | 0.252295E+09 | 0.981097E+09 | 0.298386E+09 | 0.682711E+09 | 0.00 | 0.00 |
June | 0.136264E+10 | 94688361.77 | 0.102945E+10 | 0.337812E+09 | 0.691635E+09 | 0.00 | 0.00 |
July | 0.146767E+10 | 25113175.44 | 0.100326E+10 | 0.302165E+09 | 0.701093E+09 | 0.00 | 0.00 |
August | 0.153420E+10 | 58949605.53 | 0.106064E+10 | 0.402130E+09 | 0.658510E+09 | 0.00 | 0.00 |
September | 0.931735E+09 | 0.164465E+09 | 0.738174E+09 | 0.259822E+09 | 0.478352E+09 | 0.00 | 0.00 |
October | 0.797571E+09 | 0.402142E+09 | 0.737978E+09 | 0.297155E+09 | 0.440823E+09 | 0.00 | 0.00 |
November | 0.226026E+09 | 0.664977E+09 | 0.364867E+09 | 81216406.75 | 0.283651E+09 | 0.00 | 0.00 |
December | 0.157328E+09 | 0.927889E+09 | 0.316056E+09 | 0.109532E+09 | 0.206524E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.936377E+10 | 0.567070E+10 | 0.856207E+10 | 0.291242E+10 | 0.564965E+10 | 0.00 | 0.00 |
Minimum of Months | 0.157328E+09 | 25113175.44 | 0.316056E+09 | 81216406.75 | 0.206524E+09 | 0.00 | 0.00 |
Maximum of Months | 0.153420E+10 | 0.103037E+10 | 0.106064E+10 | 0.402130E+09 | 0.701093E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.289244E+09 | 0.261477E+09 | 0.297010E+09 | 0.194901E+09 | 0.102108E+09 | 0.00 | 0.00 |
February | 0.349229E+09 | 0.243422E+09 | 0.355024E+09 | 0.235958E+09 | 0.119066E+09 | 0.00 | 0.00 |
March | 0.361686E+09 | 0.197435E+09 | 0.348254E+09 | 0.191709E+09 | 0.156545E+09 | 0.00 | 0.00 |
April | 0.292304E+09 | 0.136938E+09 | 0.268259E+09 | 0.108531E+09 | 0.159729E+09 | 0.00 | 0.00 |
May | 0.277222E+09 | 86334040.19 | 0.238083E+09 | 48743591.57 | 0.189339E+09 | 0.00 | 0.00 |
June | 0.295916E+09 | 37667383.94 | 0.217557E+09 | 33520696.39 | 0.184036E+09 | 0.00 | 0.00 |
July | 0.354339E+09 | 14581042.49 | 0.233915E+09 | 39479779.53 | 0.194435E+09 | 0.00 | 0.00 |
August | 0.470218E+09 | 25307151.50 | 0.313305E+09 | 0.115575E+09 | 0.197731E+09 | 0.00 | 0.00 |
September | 0.422922E+09 | 61007818.16 | 0.319956E+09 | 0.160645E+09 | 0.159311E+09 | 0.00 | 0.00 |
October | 0.567322E+09 | 0.131883E+09 | 0.467223E+09 | 0.292988E+09 | 0.174235E+09 | 0.00 | 0.00 |
November | 0.325928E+09 | 0.188638E+09 | 0.313085E+09 | 0.187811E+09 | 0.125275E+09 | 0.00 | 0.00 |
December | 0.323239E+09 | 0.240881E+09 | 0.320886E+09 | 0.227910E+09 | 92976446.14 | 0.00 | 0.00 |
Annual Sum or Average | 0.432957E+10 | 0.162557E+10 | 0.369256E+10 | 0.183777E+10 | 0.185479E+10 | 0.00 | 0.00 |
Minimum of Months | 0.277222E+09 | 14581042.49 | 0.217557E+09 | 33520696.39 | 92976446.14 | 0.00 | 0.00 |
Maximum of Months | 0.567322E+09 | 0.261477E+09 | 0.467223E+09 | 0.292988E+09 | 0.197731E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 3788975.13 | 0.312862E+09 | 57160472.40 | 0.00 | 57160472.40 | 0.00 | 0.00 |
February | 7619990.17 | 0.285580E+09 | 70651943.00 | 0.00 | 70651943.00 | 0.00 | 0.00 |
March | 43383682.13 | 0.201212E+09 | 0.108500E+09 | 2259.91 | 0.108497E+09 | 0.00 | 0.00 |
April | 89873410.25 | 0.127255E+09 | 0.126358E+09 | 520654.15 | 0.125837E+09 | 0.00 | 0.00 |
May | 0.183712E+09 | 67581883.40 | 0.173664E+09 | 6355606.08 | 0.167308E+09 | 0.00 | 0.00 |
June | 0.243495E+09 | 22738375.97 | 0.177301E+09 | 9430371.18 | 0.167871E+09 | 0.00 | 0.00 |
July | 0.284291E+09 | 4822951.90 | 0.177826E+09 | 6940076.94 | 0.170886E+09 | 0.00 | 0.00 |
August | 0.252164E+09 | 13099673.25 | 0.157258E+09 | 2089481.97 | 0.155168E+09 | 0.00 | 0.00 |
September | 0.142890E+09 | 42613322.58 | 0.114591E+09 | 66617.56 | 0.114525E+09 | 0.00 | 0.00 |
October | 88452923.59 | 0.111895E+09 | 0.102392E+09 | 0.00 | 0.102392E+09 | 0.00 | 0.00 |
November | 23112353.82 | 0.198561E+09 | 69501271.94 | 0.00 | 69501271.94 | 0.00 | 0.00 |
December | 2616352.80 | 0.282667E+09 | 49859143.80 | 0.00 | 49859143.80 | 0.00 | 0.00 |
Annual Sum or Average | 0.136540E+10 | 0.167089E+10 | 0.138506E+10 | 25405067.78 | 0.135966E+10 | 0.00 | 0.00 |
Minimum of Months | 2616352.80 | 4822951.90 | 49859143.80 | 0.00 | 49859143.80 | 0.00 | 0.00 |
Maximum of Months | 0.284291E+09 | 0.312862E+09 | 0.177826E+09 | 9430371.18 | 0.170886E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.500609E+09 | 0.975101E+09 | 0.649253E+09 | 0.354712E+09 | 0.294541E+09 | 0.00 | 0.00 |
February | 0.677014E+09 | 0.868761E+09 | 0.833601E+09 | 0.476496E+09 | 0.357104E+09 | 0.00 | 0.00 |
March | 0.921342E+09 | 0.670037E+09 | 0.989505E+09 | 0.475173E+09 | 0.514332E+09 | 0.00 | 0.00 |
April | 0.101309E+10 | 0.437990E+09 | 0.977300E+09 | 0.417431E+09 | 0.559869E+09 | 0.00 | 0.00 |
May | 0.128919E+10 | 0.252000E+09 | 0.109847E+10 | 0.380074E+09 | 0.718394E+09 | 0.00 | 0.00 |
June | 0.133161E+10 | 93015259.66 | 0.991622E+09 | 0.302565E+09 | 0.689057E+09 | 0.00 | 0.00 |
July | 0.153667E+10 | 24306682.24 | 0.103833E+10 | 0.317885E+09 | 0.720441E+09 | 0.00 | 0.00 |
August | 0.179647E+10 | 57505440.00 | 0.123314E+10 | 0.524115E+09 | 0.709025E+09 | 0.00 | 0.00 |
September | 0.130659E+10 | 0.161785E+09 | 0.100915E+10 | 0.475251E+09 | 0.533897E+09 | 0.00 | 0.00 |
October | 0.134017E+10 | 0.396865E+09 | 0.115278E+10 | 0.623702E+09 | 0.529077E+09 | 0.00 | 0.00 |
November | 0.674020E+09 | 0.643016E+09 | 0.732263E+09 | 0.365783E+09 | 0.366480E+09 | 0.00 | 0.00 |
December | 0.560409E+09 | 0.869933E+09 | 0.676533E+09 | 0.414864E+09 | 0.261669E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.129472E+11 | 0.545032E+10 | 0.113819E+11 | 0.512805E+10 | 0.625389E+10 | 0.00 | 0.00 |
Minimum of Months | 0.500609E+09 | 24306682.24 | 0.649253E+09 | 0.302565E+09 | 0.261669E+09 | 0.00 | 0.00 |
Maximum of Months | 0.179647E+10 | 0.975101E+09 | 0.123314E+10 | 0.623702E+09 | 0.720441E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.156033E+09 | 0.101117E+10 | 0.349358E+09 | 0.111036E+09 | 0.238322E+09 | 0.00 | 0.00 |
February | 0.253246E+09 | 0.898880E+09 | 0.478035E+09 | 0.181489E+09 | 0.296546E+09 | 0.00 | 0.00 |
March | 0.529513E+09 | 0.669409E+09 | 0.689708E+09 | 0.235492E+09 | 0.454216E+09 | 0.00 | 0.00 |
April | 0.759107E+09 | 0.432528E+09 | 0.799836E+09 | 0.282392E+09 | 0.517444E+09 | 0.00 | 0.00 |
May | 0.115955E+10 | 0.246680E+09 | 0.101786E+10 | 0.327076E+09 | 0.690780E+09 | 0.00 | 0.00 |
June | 0.124672E+10 | 91147736.72 | 0.941219E+09 | 0.272442E+09 | 0.668777E+09 | 0.00 | 0.00 |
July | 0.142374E+10 | 23893714.95 | 0.968127E+09 | 0.277199E+09 | 0.690928E+09 | 0.00 | 0.00 |
August | 0.150174E+10 | 55795721.93 | 0.103798E+10 | 0.382230E+09 | 0.655747E+09 | 0.00 | 0.00 |
September | 0.942986E+09 | 0.157829E+09 | 0.752343E+09 | 0.274488E+09 | 0.477855E+09 | 0.00 | 0.00 |
October | 0.736484E+09 | 0.391365E+09 | 0.696606E+09 | 0.257394E+09 | 0.439212E+09 | 0.00 | 0.00 |
November | 0.296812E+09 | 0.648796E+09 | 0.427694E+09 | 0.130973E+09 | 0.296721E+09 | 0.00 | 0.00 |
December | 0.169220E+09 | 0.902359E+09 | 0.337662E+09 | 0.129921E+09 | 0.207741E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.917515E+10 | 0.552986E+10 | 0.849642E+10 | 0.286213E+10 | 0.563429E+10 | 0.00 | 0.00 |
Minimum of Months | 0.156033E+09 | 23893714.95 | 0.337662E+09 | 0.111036E+09 | 0.207741E+09 | 0.00 | 0.00 |
Maximum of Months | 0.150174E+10 | 0.101117E+10 | 0.103798E+10 | 0.382230E+09 | 0.690928E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.570087E+09 | 0.126187E+10 | 0.767366E+09 | 0.422297E+09 | 0.345069E+09 | 0.00 | 0.00 |
February | 0.713396E+09 | 0.112806E+10 | 0.922294E+09 | 0.511256E+09 | 0.411038E+09 | 0.00 | 0.00 |
March | 0.873321E+09 | 0.872970E+09 | 0.989615E+09 | 0.415385E+09 | 0.574230E+09 | 0.00 | 0.00 |
April | 0.830631E+09 | 0.589186E+09 | 0.854977E+09 | 0.236284E+09 | 0.618693E+09 | 0.00 | 0.00 |
May | 0.991729E+09 | 0.344596E+09 | 0.892073E+09 | 0.119382E+09 | 0.772691E+09 | 0.00 | 0.00 |
June | 0.113659E+10 | 0.158844E+09 | 0.855479E+09 | 93059373.46 | 0.762420E+09 | 0.00 | 0.00 |
July | 0.133252E+10 | 67163543.92 | 0.892059E+09 | 0.100576E+09 | 0.791483E+09 | 0.00 | 0.00 |
August | 0.151090E+10 | 0.114020E+09 | 0.101952E+10 | 0.254945E+09 | 0.764574E+09 | 0.00 | 0.00 |
September | 0.120467E+10 | 0.258634E+09 | 0.941500E+09 | 0.348218E+09 | 0.593282E+09 | 0.00 | 0.00 |
October | 0.141332E+10 | 0.549104E+09 | 0.123416E+10 | 0.634824E+09 | 0.599335E+09 | 0.00 | 0.00 |
November | 0.737400E+09 | 0.838501E+09 | 0.828931E+09 | 0.406933E+09 | 0.421998E+09 | 0.00 | 0.00 |
December | 0.648012E+09 | 0.112593E+10 | 0.803283E+09 | 0.493817E+09 | 0.309466E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.119626E+11 | 0.730888E+10 | 0.110013E+11 | 0.403698E+10 | 0.696428E+10 | 0.00 | 0.00 |
Minimum of Months | 0.570087E+09 | 67163543.92 | 0.767366E+09 | 93059373.46 | 0.309466E+09 | 0.00 | 0.00 |
Maximum of Months | 0.151090E+10 | 0.126187E+10 | 0.123416E+10 | 0.634824E+09 | 0.791483E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.497634E+09 | 0.976267E+09 | 0.647322E+09 | 0.356975E+09 | 0.290347E+09 | 0.00 | 0.00 |
February | 0.647800E+09 | 0.876960E+09 | 0.810044E+09 | 0.455710E+09 | 0.354334E+09 | 0.00 | 0.00 |
March | 0.971597E+09 | 0.662355E+09 | 0.103759E+10 | 0.518749E+09 | 0.518839E+09 | 0.00 | 0.00 |
April | 0.100629E+10 | 0.445268E+09 | 0.968321E+09 | 0.406169E+09 | 0.562152E+09 | 0.00 | 0.00 |
May | 0.123824E+10 | 0.256092E+09 | 0.106171E+10 | 0.351385E+09 | 0.710324E+09 | 0.00 | 0.00 |
June | 0.143840E+10 | 94305764.77 | 0.107985E+10 | 0.367935E+09 | 0.711915E+09 | 0.00 | 0.00 |
July | 0.157260E+10 | 23621917.82 | 0.107346E+10 | 0.342851E+09 | 0.730606E+09 | 0.00 | 0.00 |
August | 0.182076E+10 | 57913902.00 | 0.125580E+10 | 0.544016E+09 | 0.711787E+09 | 0.00 | 0.00 |
September | 0.128639E+10 | 0.162557E+09 | 0.994979E+09 | 0.460585E+09 | 0.534394E+09 | 0.00 | 0.00 |
October | 0.139133E+10 | 0.398074E+09 | 0.119415E+10 | 0.663463E+09 | 0.530687E+09 | 0.00 | 0.00 |
November | 0.593224E+09 | 0.641401E+09 | 0.669436E+09 | 0.316026E+09 | 0.353410E+09 | 0.00 | 0.00 |
December | 0.533371E+09 | 0.873114E+09 | 0.654927E+09 | 0.394476E+09 | 0.260452E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.129976E+11 | 0.546793E+10 | 0.114476E+11 | 0.517834E+10 | 0.626925E+10 | 0.00 | 0.00 |
Minimum of Months | 0.497634E+09 | 23621917.82 | 0.647322E+09 | 0.316026E+09 | 0.260452E+09 | 0.00 | 0.00 |
Maximum of Months | 0.182076E+10 | 0.976267E+09 | 0.125580E+10 | 0.663463E+09 | 0.730606E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.167528E+09 | 0.102586E+10 | 0.347427E+09 | 0.113300E+09 | 0.234127E+09 | 0.00 | 0.00 |
February | 0.251020E+09 | 0.933903E+09 | 0.454479E+09 | 0.160704E+09 | 0.293776E+09 | 0.00 | 0.00 |
March | 0.585949E+09 | 0.664116E+09 | 0.737791E+09 | 0.279068E+09 | 0.458722E+09 | 0.00 | 0.00 |
April | 0.757652E+09 | 0.440176E+09 | 0.790856E+09 | 0.271129E+09 | 0.519727E+09 | 0.00 | 0.00 |
May | 0.110949E+10 | 0.249063E+09 | 0.981097E+09 | 0.298386E+09 | 0.682711E+09 | 0.00 | 0.00 |
June | 0.135395E+10 | 91601831.34 | 0.102945E+10 | 0.337812E+09 | 0.691635E+09 | 0.00 | 0.00 |
July | 0.146055E+10 | 23018343.46 | 0.100326E+10 | 0.302165E+09 | 0.701093E+09 | 0.00 | 0.00 |
August | 0.152859E+10 | 55572598.04 | 0.106064E+10 | 0.402130E+09 | 0.658510E+09 | 0.00 | 0.00 |
September | 0.928200E+09 | 0.158905E+09 | 0.738174E+09 | 0.259822E+09 | 0.478352E+09 | 0.00 | 0.00 |
October | 0.797035E+09 | 0.392921E+09 | 0.737978E+09 | 0.297155E+09 | 0.440823E+09 | 0.00 | 0.00 |
November | 0.228196E+09 | 0.656522E+09 | 0.364867E+09 | 81216406.75 | 0.283651E+09 | 0.00 | 0.00 |
December | 0.158562E+09 | 0.921147E+09 | 0.316056E+09 | 0.109532E+09 | 0.206524E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.932672E+10 | 0.561281E+10 | 0.856207E+10 | 0.291242E+10 | 0.564965E+10 | 0.00 | 0.00 |
Minimum of Months | 0.158562E+09 | 23018343.46 | 0.316056E+09 | 81216406.75 | 0.206524E+09 | 0.00 | 0.00 |
Maximum of Months | 0.152859E+10 | 0.102586E+10 | 0.106064E+10 | 0.402130E+09 | 0.701093E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.514317E+09 | 0.509143E+09 | 0.544600E+09 | 0.357373E+09 | 0.187227E+09 | 0.00 | 0.00 |
February | 0.626423E+09 | 0.457531E+09 | 0.650976E+09 | 0.432656E+09 | 0.218320E+09 | 0.00 | 0.00 |
March | 0.653513E+09 | 0.356085E+09 | 0.638561E+09 | 0.351519E+09 | 0.287042E+09 | 0.00 | 0.00 |
April | 0.533158E+09 | 0.236863E+09 | 0.491883E+09 | 0.199003E+09 | 0.292880E+09 | 0.00 | 0.00 |
May | 0.516509E+09 | 0.133232E+09 | 0.436551E+09 | 89376714.80 | 0.347174E+09 | 0.00 | 0.00 |
June | 0.555986E+09 | 45891613.01 | 0.398915E+09 | 61463868.89 | 0.337451E+09 | 0.00 | 0.00 |
July | 0.670620E+09 | 10234254.94 | 0.428908E+09 | 72390500.62 | 0.356518E+09 | 0.00 | 0.00 |
August | 0.878638E+09 | 27513527.85 | 0.574480E+09 | 0.211919E+09 | 0.362561E+09 | 0.00 | 0.00 |
September | 0.782281E+09 | 83410388.13 | 0.586675E+09 | 0.294560E+09 | 0.292115E+09 | 0.00 | 0.00 |
October | 0.104103E+10 | 0.207312E+09 | 0.856705E+09 | 0.537226E+09 | 0.319480E+09 | 0.00 | 0.00 |
November | 0.592489E+09 | 0.339217E+09 | 0.574076E+09 | 0.344371E+09 | 0.229705E+09 | 0.00 | 0.00 |
December | 0.581071E+09 | 0.455752E+09 | 0.588380E+09 | 0.417897E+09 | 0.170482E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.794604E+10 | 0.286218E+10 | 0.677071E+10 | 0.336976E+10 | 0.340095E+10 | 0.00 | 0.00 |
Minimum of Months | 0.514317E+09 | 10234254.94 | 0.398915E+09 | 61463868.89 | 0.170482E+09 | 0.00 | 0.00 |
Maximum of Months | 0.104103E+10 | 0.509143E+09 | 0.856705E+09 | 0.537226E+09 | 0.362561E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 11159821.63 | 0.315464E+10 | 0.500069E+09 | 0.00 | 0.500069E+09 | 0.00 | 0.00 |
February | 34614031.82 | 0.287222E+10 | 0.618099E+09 | 0.00 | 0.618099E+09 | 0.00 | 0.00 |
March | 0.276116E+09 | 0.211767E+10 | 0.949209E+09 | 19770.80 | 0.949189E+09 | 0.00 | 0.00 |
April | 0.640459E+09 | 0.138749E+10 | 0.110544E+10 | 4554947.47 | 0.110089E+10 | 0.00 | 0.00 |
May | 0.138447E+10 | 0.783825E+09 | 0.151930E+10 | 55602076.65 | 0.146370E+10 | 0.00 | 0.00 |
June | 0.189835E+10 | 0.358325E+09 | 0.155112E+10 | 82501686.62 | 0.146862E+10 | 0.00 | 0.00 |
July | 0.221979E+10 | 0.157246E+09 | 0.155571E+10 | 60715325.16 | 0.149500E+10 | 0.00 | 0.00 |
August | 0.194628E+10 | 0.240249E+09 | 0.137577E+10 | 18279851.73 | 0.135749E+10 | 0.00 | 0.00 |
September | 0.106673E+10 | 0.587043E+09 | 0.100250E+10 | 582804.32 | 0.100192E+10 | 0.00 | 0.00 |
October | 0.629417E+09 | 0.125487E+10 | 0.895777E+09 | 0.00 | 0.895777E+09 | 0.00 | 0.00 |
November | 0.134807E+09 | 0.210220E+10 | 0.608032E+09 | 0.00 | 0.608032E+09 | 0.00 | 0.00 |
December | 7950607.59 | 0.291218E+10 | 0.436193E+09 | 0.00 | 0.436193E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.102501E+11 | 0.179279E+11 | 0.121172E+11 | 0.222256E+09 | 0.118950E+11 | 0.00 | 0.00 |
Minimum of Months | 7950607.59 | 0.157246E+09 | 0.436193E+09 | 0.00 | 0.436193E+09 | 0.00 | 0.00 |
Maximum of Months | 0.221979E+10 | 0.315464E+10 | 0.155571E+10 | 82501686.62 | 0.149500E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 7588443.67 | 0.324885E+10 | 0.500069E+09 | 0.00 | 0.500069E+09 | 0.00 | 0.00 |
February | 29170304.40 | 0.295327E+10 | 0.618099E+09 | 0.00 | 0.618099E+09 | 0.00 | 0.00 |
March | 0.255415E+09 | 0.217993E+10 | 0.949209E+09 | 19770.80 | 0.949189E+09 | 0.00 | 0.00 |
April | 0.612733E+09 | 0.142963E+10 | 0.110544E+10 | 4554947.47 | 0.110089E+10 | 0.00 | 0.00 |
May | 0.135279E+10 | 0.806096E+09 | 0.151930E+10 | 55602076.65 | 0.146370E+10 | 0.00 | 0.00 |
June | 0.187558E+10 | 0.372397E+09 | 0.155112E+10 | 82501686.62 | 0.146862E+10 | 0.00 | 0.00 |
July | 0.219908E+10 | 0.168115E+09 | 0.155571E+10 | 60715325.16 | 0.149500E+10 | 0.00 | 0.00 |
August | 0.192498E+10 | 0.251630E+09 | 0.137577E+10 | 18279851.73 | 0.135749E+10 | 0.00 | 0.00 |
September | 0.104589E+10 | 0.608403E+09 | 0.100250E+10 | 582804.32 | 0.100192E+10 | 0.00 | 0.00 |
October | 0.606690E+09 | 0.128942E+10 | 0.895777E+09 | 0.00 | 0.895777E+09 | 0.00 | 0.00 |
November | 0.122126E+09 | 0.217023E+10 | 0.608032E+09 | 0.00 | 0.608032E+09 | 0.00 | 0.00 |
December | 5819826.30 | 0.300042E+10 | 0.436193E+09 | 0.00 | 0.436193E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.100379E+11 | 0.184784E+11 | 0.121172E+11 | 0.222256E+09 | 0.118950E+11 | 0.00 | 0.00 |
Minimum of Months | 5819826.30 | 0.168115E+09 | 0.436193E+09 | 0.00 | 0.436193E+09 | 0.00 | 0.00 |
Maximum of Months | 0.219908E+10 | 0.324885E+10 | 0.155571E+10 | 82501686.62 | 0.149500E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.651720E+09 | 0.210176E+10 | 0.998571E+09 | 0.465732E+09 | 0.532839E+09 | 0.00 | 0.00 |
February | 0.937634E+09 | 0.185054E+10 | 0.131158E+10 | 0.657960E+09 | 0.653621E+09 | 0.00 | 0.00 |
March | 0.152277E+10 | 0.146514E+10 | 0.167913E+10 | 0.710631E+09 | 0.968503E+09 | 0.00 | 0.00 |
April | 0.191867E+10 | 0.982208E+09 | 0.177704E+10 | 0.699783E+09 | 0.107726E+10 | 0.00 | 0.00 |
May | 0.268617E+10 | 0.597567E+09 | 0.211621E+10 | 0.707104E+09 | 0.140911E+10 | 0.00 | 0.00 |
June | 0.287000E+10 | 0.278333E+09 | 0.193274E+10 | 0.574969E+09 | 0.135777E+10 | 0.00 | 0.00 |
July | 0.329321E+10 | 0.129286E+09 | 0.200635E+10 | 0.595046E+09 | 0.141130E+10 | 0.00 | 0.00 |
August | 0.362751E+10 | 0.185116E+09 | 0.227100E+10 | 0.906291E+09 | 0.136471E+10 | 0.00 | 0.00 |
September | 0.251413E+10 | 0.397199E+09 | 0.176141E+10 | 0.749700E+09 | 0.101171E+10 | 0.00 | 0.00 |
October | 0.226463E+10 | 0.846630E+09 | 0.184930E+10 | 0.881059E+09 | 0.968244E+09 | 0.00 | 0.00 |
November | 0.102357E+10 | 0.139537E+10 | 0.115991E+10 | 0.496737E+09 | 0.663171E+09 | 0.00 | 0.00 |
December | 0.733908E+09 | 0.187990E+10 | 0.101416E+10 | 0.544767E+09 | 0.469389E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.240439E+11 | 0.121090E+11 | 0.198774E+11 | 0.798978E+10 | 0.118876E+11 | 0.00 | 0.00 |
Minimum of Months | 0.651720E+09 | 0.129286E+09 | 0.998571E+09 | 0.465732E+09 | 0.469389E+09 | 0.00 | 0.00 |
Maximum of Months | 0.362751E+10 | 0.210176E+10 | 0.227100E+10 | 0.906291E+09 | 0.141130E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.124065E+10 | 0.225370E+10 | 0.155773E+10 | 0.909713E+09 | 0.648020E+09 | 0.00 | 0.00 |
February | 0.154003E+10 | 0.200883E+10 | 0.186898E+10 | 0.110135E+10 | 0.767631E+09 | 0.00 | 0.00 |
March | 0.177804E+10 | 0.156864E+10 | 0.195088E+10 | 0.894818E+09 | 0.105606E+10 | 0.00 | 0.00 |
April | 0.160215E+10 | 0.106206E+10 | 0.163106E+10 | 0.508134E+09 | 0.112293E+10 | 0.00 | 0.00 |
May | 0.178749E+10 | 0.631912E+09 | 0.163208E+10 | 0.246574E+09 | 0.138551E+10 | 0.00 | 0.00 |
June | 0.200682E+10 | 0.301993E+09 | 0.154719E+10 | 0.184741E+09 | 0.136244E+10 | 0.00 | 0.00 |
July | 0.236880E+10 | 0.138008E+09 | 0.162511E+10 | 0.205087E+09 | 0.142002E+10 | 0.00 | 0.00 |
August | 0.281778E+10 | 0.214008E+09 | 0.193399E+10 | 0.545718E+09 | 0.138827E+10 | 0.00 | 0.00 |
September | 0.233557E+10 | 0.470117E+09 | 0.183707E+10 | 0.750019E+09 | 0.108705E+10 | 0.00 | 0.00 |
October | 0.288081E+10 | 0.961772E+09 | 0.248786E+10 | 0.136754E+10 | 0.112033E+10 | 0.00 | 0.00 |
November | 0.154483E+10 | 0.149357E+10 | 0.166978E+10 | 0.876615E+09 | 0.793160E+09 | 0.00 | 0.00 |
December | 0.141021E+10 | 0.201250E+10 | 0.164728E+10 | 0.106378E+10 | 0.583500E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.233132E+11 | 0.131171E+11 | 0.213890E+11 | 0.865408E+10 | 0.127349E+11 | 0.00 | 0.00 |
Minimum of Months | 0.124065E+10 | 0.138008E+09 | 0.154719E+10 | 0.184741E+09 | 0.583500E+09 | 0.00 | 0.00 |
Maximum of Months | 0.288081E+10 | 0.225370E+10 | 0.248786E+10 | 0.136754E+10 | 0.142002E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 1.17 | -0.7 | -4.4 | 5.65 | -10.4 | 36.91 | 88.07 | 0.05 |
February | -0.2 | -2.6 | -7.5 | 5.07 | -13.4 | 46.98 | 136.68 | 0.04 |
March | 5.59 | 3.43 | 0.29 | 5.58 | -4.1 | 68.24 | 153.73 | 0.03 |
April | 10.94 | 8.00 | 4.75 | 4.99 | 0.53 | 82.64 | 161.98 | 0.05 |
May | 16.05 | 12.31 | 9.14 | 4.42 | 7.77 | 109.28 | 173.60 | 0.03 |
June | 21.71 | 18.08 | 15.84 | 4.92 | 13.23 | 112.36 | 186.51 | 0.01 |
July | 25.05 | 21.76 | 20.26 | 4.06 | 17.39 | 114.46 | 172.96 | 0.02 |
August | 24.79 | 19.84 | 17.14 | 4.19 | 14.42 | 95.56 | 226.16 | 0.00 |
September | 19.96 | 15.96 | 13.24 | 3.91 | 10.59 | 73.65 | 166.08 | 0.03 |
October | 14.02 | 11.03 | 7.95 | 4.86 | 2.64 | 61.34 | 179.75 | 0.00 |
November | 7.31 | 4.98 | 2.14 | 5.60 | -4.0 | 48.23 | 90.71 | 0.03 |
December | 3.33 | 0.91 | -2.8 | 5.64 | -8.5 | 30.23 | 98.59 | 0.04 |
Annual Sum or Average | 12.55 | 9.49 | 6.43 | 4.91 | 2.28 | 73.48 | 153.05 | 0.03 |
Minimum of Months | -0.2 | -2.6 | -7.5 | 3.91 | -13.4 | 30.23 | 88.07 | 0.00 |
Maximum of Months | 25.05 | 21.76 | 20.26 | 5.65 | 17.39 | 114.46 | 226.16 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.20 | 24-JAN-12:20 | 11.81 | 11.50 | 1.00 | 8.15 | 93.67 | 0.00 |
February | 10.00 | 20-FEB-11:00 | 4.36 | -3.3 | 2.60 | -3.9 | 151.50 | 540.00 |
March | 22.20 | 27-MAR-15:00 | 16.34 | 12.80 | 6.70 | 11.65 | 136.50 | 590.00 |
April | 26.70 | 07-APR-12:00 | 16.40 | 9.40 | 6.20 | 11.65 | 179.00 | 713.50 |
May | 30.00 | 30-MAY-12:00 | 18.00 | 10.60 | 5.20 | 17.39 | 233.50 | 730.00 |
June | 36.70 | 19-JUN-11:00 | 24.28 | 19.40 | 5.20 | 24.83 | 185.00 | 771.50 |
July | 33.90 | 07-JUL-11:00 | 23.31 | 18.90 | 3.60 | 23.82 | 331.00 | 570.00 |
August | 33.90 | 24-AUG-14:00 | 20.23 | 12.80 | 8.80 | 21.61 | 240.00 | 432.00 |
September | 31.10 | 01-SEP-13:00 | 17.34 | 8.30 | 4.60 | 18.46 | 182.00 | 662.00 |
October | 25.00 | 04-OCT-12:00 | 18.54 | 15.00 | 5.20 | 11.27 | 171.50 | 695.00 |
November | 17.80 | 04-NOV-12:20 | 12.57 | 8.50 | 3.60 | 6.15 | 182.50 | 595.67 |
December | 12.20 | 17-DEC-12:20 | 4.65 | -6.1 | 4.27 | -4.7 | 53.17 | 801.67 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.00 | 4.36 | -6.1 | 1.00 | -4.7 | 53.17 | 0.00 | |
Maximum of Months | 36.70 | 24.28 | 19.40 | 8.80 | 24.83 | 331.00 | 801.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -12.2 | 02-JAN-04:00 | -13.6 | -19.4 | 2.60 | -30.7 | 0.00 | 0.00 |
February | -13.9 | 06-FEB-02:00 | -15.3 | -22.8 | 7.20 | -34.1 | 0.00 | 0.00 |
March | -5.0 | 23-MAR-03:00 | -7.6 | -14.4 | 1.50 | -23.9 | 0.00 | 0.00 |
April | 2.20 | 01-APR-03:00 | 0.57 | -1.7 | 3.10 | -6.6 | 0.00 | 0.00 |
May | 6.10 | 01-MAY-04:00 | 4.33 | 2.20 | 3.60 | -9.7 | 25.50 | 0.00 |
June | 13.30 | 03-JUN-02:00 | 9.35 | 5.60 | 4.60 | -2.1 | 0.00 | 0.00 |
July | 18.30 | 02-JUL-02:00 | 17.54 | 17.20 | 0.00 | 5.33 | 0.00 | 0.00 |
August | 15.00 | 08-AUG-04:00 | 12.47 | 10.60 | 3.10 | 3.06 | 0.00 | 0.00 |
September | 10.00 | 24-SEP-05:00 | 8.56 | 7.20 | 2.60 | -3.4 | 18.50 | 158.50 |
October | 2.20 | 09-OCT-03:00 | 1.71 | 1.10 | 0.00 | -13.7 | 0.00 | 0.00 |
November | -4.4 | 24-NOV-05:00 | -6.2 | -10.0 | 1.50 | -19.7 | 0.00 | 0.00 |
December | -8.3 | 31-DEC-23:00 | -10.6 | -18.9 | 9.30 | -26.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -13.9 | -15.3 | -22.8 | 0.00 | -34.1 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 17.54 | 17.20 | 9.30 | 5.33 | 25.50 | 158.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.93 | 24-JAN-11:00 | 12.20 | 11.70 | 1.50 | 8.15 | 103.00 | 0.00 |
February | 6.67 | 28-FEB-09:00 | 7.20 | 6.10 | 4.10 | 2.01 | 101.50 | 0.00 |
March | 16.99 | 27-MAR-12:00 | 20.60 | 15.00 | 3.60 | 10.50 | 295.50 | 565.50 |
April | 17.70 | 09-APR-10:00 | 21.70 | 15.60 | 4.10 | 14.84 | 244.50 | 281.50 |
May | 20.43 | 31-MAY-12:00 | 26.10 | 17.80 | 4.10 | 17.03 | 214.00 | 772.00 |
June | 24.96 | 15-JUN-11:00 | 31.10 | 22.80 | 5.20 | 22.47 | 380.00 | 460.00 |
July | 26.10 | 08-JUL-11:00 | 32.20 | 23.90 | 5.20 | 22.47 | 354.00 | 501.50 |
August | 25.84 | 03-AUG-13:00 | 30.00 | 24.40 | 6.20 | 20.57 | 298.00 | 500.00 |
September | 23.57 | 07-SEP-13:00 | 27.20 | 22.20 | 6.20 | 15.02 | 148.00 | 730.50 |
October | 19.76 | 25-OCT-10:00 | 25.00 | 17.20 | 7.70 | 14.84 | 189.00 | 308.50 |
November | 16.10 | 10-NOV-07:00 | 16.10 | 16.10 | 8.20 | 12.98 | 71.50 | 0.00 |
December | 10.26 | 25-DEC-08:00 | 10.60 | 10.00 | 3.60 | 6.15 | 43.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.67 | 7.20 | 6.10 | 1.50 | 2.01 | 43.00 | 0.00 | |
Maximum of Months | 26.10 | 32.20 | 24.40 | 8.20 | 22.47 | 380.00 | 772.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.70 | 18-JAN-15:00 | 12.20 | 11.93 | 14.90 | 8.15 | 22.00 | 2.00 |
February | 6.10 | 28-FEB-10:20 | 7.03 | 6.58 | 3.43 | 1.87 | 109.83 | 0.00 |
March | 15.00 | 27-MAR-12:20 | 18.00 | 16.18 | 3.93 | 10.11 | 271.83 | 611.17 |
April | 15.60 | 09-APR-10:00 | 21.70 | 17.70 | 4.10 | 14.84 | 244.50 | 281.50 |
May | 18.00 | 18-MAY-09:00 | 18.00 | 18.00 | 4.60 | 15.39 | 265.50 | 12.00 |
June | 22.80 | 15-JUN-11:00 | 31.10 | 24.96 | 5.20 | 22.47 | 380.00 | 460.00 |
July | 24.40 | 09-JUL-07:00 | 27.20 | 25.17 | 2.10 | 15.39 | 195.00 | 504.00 |
August | 25.00 | 03-AUG-19:00 | 26.10 | 25.32 | 5.70 | 19.35 | 0.00 | 0.00 |
September | 22.20 | 07-SEP-13:00 | 27.20 | 23.57 | 6.20 | 15.02 | 148.00 | 730.50 |
October | 18.30 | 05-OCT-18:00 | 19.40 | 18.62 | 7.70 | 6.55 | 0.00 | 0.00 |
November | 16.10 | 10-NOV-07:00 | 16.10 | 16.10 | 8.20 | 12.98 | 71.50 | 0.00 |
December | 10.00 | 25-DEC-08:00 | 10.60 | 10.26 | 3.60 | 6.15 | 43.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.10 | 7.03 | 6.58 | 2.10 | 1.87 | 0.00 | 0.00 | |
Maximum of Months | 25.00 | 31.10 | 25.32 | 14.90 | 22.47 | 380.00 | 730.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.03 | 13.58 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 9.54 | 21.42 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.65 | 30.29 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 13.15 | 37.02 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 16.36 | 45.86 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 19.42 | 49.74 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 21.50 | 48.12 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 22.05 | 49.54 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 20.89 | 34.71 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 18.36 | 29.93 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 15.14 | 17.00 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 12.10 | 12.41 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 15.80 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 9.54 | 12.41 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 22.05 | 49.74 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWH BOOSTER E WATER HEATER
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.770511E+10 | -0.754279E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162323089.7 | 81.21 | 0.00 | 0.00 |
February | 0.696260E+10 | -0.681596E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -146634554.5 | 81.21 | 0.00 | 0.00 |
March | 0.770324E+10 | -0.754148E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -161759541.7 | 81.21 | 0.00 | 0.00 |
April | 0.746509E+10 | -0.730859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -156499009.9 | 81.21 | 0.00 | 0.00 |
May | 0.770447E+10 | -0.754279E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -161680925.5 | 81.21 | 0.00 | 0.00 |
June | 0.745685E+10 | -0.730052E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -156323209.5 | 81.21 | 0.00 | 0.00 |
July | 0.771233E+10 | -0.755085E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -161486406.6 | 81.21 | 0.00 | 0.00 |
August | 0.770426E+10 | -0.754280E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -161452484.2 | 81.21 | 0.00 | 0.00 |
September | 0.746634E+10 | -0.730993E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -156414477.2 | 81.21 | 0.00 | 0.00 |
October | 0.770312E+10 | -0.754144E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -161687216.5 | 81.21 | 0.00 | 0.00 |
November | 0.744899E+10 | -0.729242E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -156569392.4 | 81.21 | 0.00 | 0.00 |
December | 0.771297E+10 | -0.755086E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162103272.8 | 81.21 | 0.00 | 0.00 |
Annual Sum or Average | 0.907454E+11 | -0.888404E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.190493E+10 | 81.21 | 0.00 | 0.00 |
Minimum of Months | 0.696260E+10 | -0.755086E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -162323089.7 | 81.21 | 0.00 | 0.00 |
Maximum of Months | 0.771297E+10 | -0.681596E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -146634554.5 | 81.21 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWH LAUNDRY G WATER HEATER
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.122409E+12 | -0.120669E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.174051E+10 | 81.27 | 0.00 | 0.00 |
February | 0.111344E+12 | -0.109763E+12 | 0.00 | 0.00 | 672.00 | 0.00 | -0.158092E+10 | 81.27 | 0.00 | 0.00 |
March | 0.121352E+12 | -0.119595E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.175716E+10 | 81.27 | 0.00 | 0.00 |
April | 0.113316E+12 | -0.111608E+12 | 0.00 | 0.00 | 720.00 | 0.00 | -0.170810E+10 | 81.26 | 0.00 | 0.00 |
May | 0.111635E+12 | -0.109865E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.177047E+10 | 81.25 | 0.00 | 0.00 |
June | 0.102994E+12 | -0.101291E+12 | 0.00 | 0.00 | 720.00 | 0.00 | -0.170304E+10 | 81.26 | 0.00 | 0.00 |
July | 0.102882E+12 | -0.101134E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.174786E+10 | 81.25 | 0.00 | 0.00 |
August | 0.101948E+12 | -0.100211E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.173707E+10 | 81.24 | 0.00 | 0.00 |
September | 0.100547E+12 | -0.988729E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.167440E+10 | 81.24 | 0.00 | 0.00 |
October | 0.108194E+12 | -0.106466E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.172806E+10 | 81.25 | 0.00 | 0.00 |
November | 0.109993E+12 | -0.108321E+12 | 0.00 | 0.00 | 720.00 | 0.00 | -0.167218E+10 | 81.25 | 0.00 | 0.00 |
December | 0.118843E+12 | -0.117112E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.173081E+10 | 81.26 | 0.00 | 0.00 |
Annual Sum or Average | 0.132546E+13 | -0.130491E+13 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205506E+11 | 81.25 | 0.00 | 0.00 |
Minimum of Months | 0.100547E+12 | -0.120669E+12 | 0.00 | 0.00 | 672.00 | 0.00 | -0.177047E+10 | 81.24 | 0.00 | 0.00 |
Maximum of Months | 0.122409E+12 | -0.988729E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158092E+10 | 81.27 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.730145E+11 | -0.715330E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.148155E+10 | 58.98 | 0.00 | 0.00 |
February | 0.666208E+11 | -0.652704E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -0.135034E+10 | 58.98 | 0.00 | 0.00 |
March | 0.721896E+11 | -0.706847E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.150481E+10 | 58.98 | 0.00 | 0.00 |
April | 0.663049E+11 | -0.648378E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.146705E+10 | 58.98 | 0.00 | 0.00 |
May | 0.638333E+11 | -0.623095E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.152378E+10 | 58.98 | 0.00 | 0.00 |
June | 0.574448E+11 | -0.559847E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.146008E+10 | 58.98 | 0.00 | 0.00 |
July | 0.562410E+11 | -0.547486E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.149248E+10 | 58.98 | 0.00 | 0.00 |
August | 0.554849E+11 | -0.540069E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.147798E+10 | 58.98 | 0.00 | 0.00 |
September | 0.552932E+11 | -0.538724E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.142082E+10 | 58.98 | 0.00 | 0.00 |
October | 0.608114E+11 | -0.593462E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.146522E+10 | 58.98 | 0.00 | 0.00 |
November | 0.634053E+11 | -0.619877E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.141760E+10 | 58.98 | 0.00 | 0.00 |
December | 0.699672E+11 | -0.684987E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.146847E+10 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.760611E+12 | -0.743081E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.175302E+11 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.552932E+11 | -0.715330E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -0.152378E+10 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.730145E+11 | -0.538724E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.135034E+10 | 58.98 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: LOBBY_FLR_1_DAYLCTRL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 199.50 | 0.93 | 0.93 | 01-JAN-07:49 | 5752.10 | 37.03 | 197.00 | 248.83 | 2745.59 | 33.81 | 188.00 | 189.67 |
February | 216.00 | 0.93 | 0.93 | 01-FEB-07:40 | 8418.83 | 37.65 | 208.33 | 260.00 | 1191.73 | 27.31 | 206.83 | 227.33 |
March | 275.00 | 0.93 | 0.93 | 01-MAR-06:00 | 4067.36 | 25.80 | 163.50 | 328.83 | 736.97 | 22.68 | 209.67 | 263.67 |
April | 261.17 | 0.93 | 0.93 | 01-APR-06:10 | 1445.62 | 20.50 | 84.83 | 345.67 | 588.98 | 22.24 | 203.33 | 281.50 |
May | 372.00 | 0.93 | 0.93 | 01-MAY-05:40 | 1308.04 | 20.22 | 124.17 | 397.67 | 519.20 | 21.93 | 243.67 | 320.50 |
June | 351.83 | 0.93 | 0.93 | 01-JUN-05:10 | 1240.43 | 20.13 | 92.17 | 387.67 | 500.41 | 21.87 | 250.33 | 321.67 |
July | 365.17 | 0.93 | 0.93 | 01-JUL-05:19 | 1383.00 | 20.29 | 124.83 | 397.00 | 547.52 | 22.02 | 268.67 | 325.67 |
August | 389.17 | 0.93 | 0.93 | 01-AUG-05:40 | 1480.96 | 20.57 | 155.50 | 375.17 | 599.15 | 22.29 | 308.00 | 325.17 |
September | 285.33 | 0.93 | 0.93 | 01-SEP-05:00 | 1648.08 | 20.68 | 98.17 | 329.17 | 665.12 | 22.45 | 236.50 | 276.67 |
October | 305.50 | 0.93 | 0.93 | 01-OCT-14:39 | 8133.96 | 35.73 | 284.00 | 310.17 | 1018.57 | 25.01 | 277.33 | 282.33 |
November | 240.83 | 0.93 | 0.93 | 01-NOV-06:49 | 5706.93 | 36.47 | 235.00 | 260.17 | 1514.66 | 29.94 | 223.67 | 229.67 |
December | 211.17 | 0.93 | 0.93 | 01-DEC-07:30 | 5342.60 | 38.01 | 208.00 | 248.83 | 4126.65 | 37.99 | 207.17 | 208.50 |
Annual Sum or Average | 3472.67 | 0.93 | 3433.74 | 26.38 | 1975.50 | 3889.17 | 1065.78 | 24.92 | 2823.17 | 3252.33 | ||
Minimum of Months | 199.50 | 0.93 | 0.93 | 1240.43 | 20.13 | 84.83 | 248.83 | 500.41 | 21.87 | 188.00 | 189.67 | |
Maximum of Months | 389.17 | 0.93 | 0.93 | 8418.83 | 38.01 | 284.00 | 397.67 | 4126.65 | 37.99 | 308.00 | 325.67 |
Report: DaylightingReportMonthly
For: CAFE_FLR_1_DAYLCTRL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 199.50 | 0.62 | 0.61 | 01-JAN-07:40 | 6185.22 | 37.09 | 197.00 | 260.50 | 3179.37 | 33.77 | 190.17 | 220.83 |
February | 216.00 | 0.62 | 0.61 | 01-FEB-07:40 | 8914.43 | 37.73 | 208.33 | 269.33 | 1686.90 | 27.00 | 195.50 | 246.67 |
March | 275.00 | 0.62 | 0.61 | 01-MAR-06:49 | 4472.40 | 25.93 | 155.50 | 337.50 | 1140.36 | 22.70 | 221.33 | 307.50 |
April | 261.17 | 0.62 | 0.61 | 01-APR-05:00 | 1758.70 | 20.81 | 91.33 | 358.17 | 901.28 | 22.39 | 240.33 | 320.67 |
May | 372.00 | 0.62 | 0.61 | 01-MAY-05:40 | 1533.17 | 20.81 | 156.00 | 412.00 | 743.54 | 22.34 | 273.83 | 372.33 |
June | 351.83 | 0.62 | 0.61 | 01-JUN-04:00 | 1455.71 | 20.73 | 155.33 | 404.83 | 714.97 | 22.28 | 283.83 | 362.00 |
July | 365.17 | 0.62 | 0.61 | 01-JUL-05:10 | 1612.27 | 20.87 | 171.17 | 414.00 | 775.94 | 22.42 | 296.83 | 368.17 |
August | 389.17 | 0.63 | 0.61 | 01-AUG-05:19 | 1770.11 | 20.95 | 183.50 | 385.00 | 887.46 | 22.51 | 321.33 | 358.67 |
September | 285.33 | 0.62 | 0.61 | 01-SEP-05:00 | 2009.72 | 20.86 | 108.00 | 340.50 | 1025.77 | 22.49 | 236.83 | 308.00 |
October | 305.50 | 0.62 | 0.61 | 01-OCT-14:39 | 8629.00 | 35.78 | 273.50 | 317.33 | 1512.06 | 24.86 | 283.67 | 300.00 |
November | 240.83 | 0.62 | 0.61 | 01-NOV-06:49 | 6110.78 | 36.55 | 235.17 | 267.83 | 1914.92 | 29.86 | 229.17 | 250.33 |
December | 211.17 | 0.63 | 0.61 | 01-DEC-07:30 | 5773.44 | 38.07 | 208.00 | 256.67 | 4555.57 | 38.00 | 204.67 | 233.67 |
Annual Sum or Average | 3472.67 | 0.62 | 3774.98 | 26.68 | 2142.83 | 4023.67 | 1405.92 | 25.05 | 2977.50 | 3648.83 | ||
Minimum of Months | 199.50 | 0.62 | 0.61 | 1455.71 | 20.73 | 91.33 | 256.67 | 714.97 | 22.28 | 190.17 | 220.83 | |
Maximum of Months | 389.17 | 0.63 | 0.61 | 8914.43 | 38.07 | 273.50 | 414.00 | 4555.57 | 38.00 | 321.33 | 372.33 |
Report: DaylightingReportMonthly
For: DINING_FLR_6_DAYLCTRL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 199.50 | 0.82 | 0.80 | 01-JAN-08:09 | 434.52 | 15.20 | 0.00 | 231.83 | 209.59 | 18.60 | 0.00 | 116.83 |
February | 216.00 | 0.82 | 0.80 | 01-FEB-08:09 | 446.61 | 15.89 | 0.00 | 247.33 | 228.99 | 19.35 | 0.00 | 155.67 |
March | 275.00 | 0.81 | 0.80 | 01-MAR-06:00 | 612.35 | 17.24 | 0.00 | 325.83 | 295.33 | 20.48 | 30.00 | 242.17 |
April | 261.17 | 0.81 | 0.80 | 01-APR-06:10 | 674.70 | 17.83 | 0.00 | 356.67 | 325.40 | 21.05 | 87.83 | 300.83 |
May | 372.00 | 0.80 | 0.80 | 01-MAY-05:40 | 926.59 | 18.52 | 0.00 | 418.17 | 413.94 | 22.41 | 250.83 | 373.67 |
June | 351.83 | 0.80 | 0.80 | 01-JUN-04:00 | 1028.76 | 19.64 | 29.00 | 410.33 | 447.19 | 23.45 | 264.83 | 376.17 |
July | 365.17 | 0.80 | 0.80 | 01-JUL-04:00 | 1033.92 | 18.58 | 0.00 | 419.83 | 446.06 | 23.09 | 271.67 | 377.17 |
August | 389.17 | 0.81 | 0.80 | 01-AUG-05:10 | 819.58 | 18.27 | 0.00 | 387.83 | 379.21 | 21.49 | 226.00 | 356.17 |
September | 285.33 | 0.81 | 0.80 | 01-SEP-05:00 | 618.25 | 17.45 | 0.00 | 334.17 | 302.12 | 20.70 | 53.67 | 271.67 |
October | 305.50 | 0.81 | 0.80 | 01-OCT-14:39 | 559.22 | 17.01 | 0.00 | 302.17 | 286.58 | 20.37 | 0.17 | 246.33 |
November | 240.83 | 0.81 | 0.80 | 01-NOV-06:00 | 488.27 | 15.75 | 0.00 | 248.83 | 228.94 | 19.07 | 0.00 | 156.17 |
December | 211.17 | 0.83 | 0.80 | 01-DEC-07:00 | 344.08 | 14.30 | 0.00 | 219.50 | 172.97 | 17.86 | 0.00 | 73.83 |
Annual Sum or Average | 3472.67 | 0.81 | 710.81 | 17.43 | 29.00 | 3902.50 | 329.62 | 20.99 | 1185.00 | 3046.67 | ||
Minimum of Months | 199.50 | 0.80 | 0.80 | 344.08 | 14.30 | 0.00 | 219.50 | 172.97 | 17.86 | 0.00 | 73.83 | |
Maximum of Months | 389.17 | 0.83 | 0.80 | 1033.92 | 19.64 | 29.00 | 419.83 | 447.19 | 23.45 | 271.67 | 377.17 |
Report: DaylightingReportMonthly
For: BANQUET_FLR_6_DAYLCTRL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 199.50 | 0.82 | 0.80 | 01-JAN-08:09 | 434.52 | 15.20 | 0.00 | 231.83 | 209.59 | 18.60 | 0.00 | 116.83 |
February | 216.00 | 0.82 | 0.80 | 01-FEB-08:09 | 446.61 | 15.89 | 0.00 | 247.33 | 228.99 | 19.35 | 0.00 | 155.67 |
March | 275.00 | 0.81 | 0.80 | 01-MAR-06:00 | 612.35 | 17.24 | 0.00 | 325.83 | 295.33 | 20.48 | 30.00 | 242.17 |
April | 261.17 | 0.81 | 0.80 | 01-APR-06:10 | 674.70 | 17.83 | 0.00 | 356.67 | 325.40 | 21.05 | 87.83 | 300.83 |
May | 372.00 | 0.80 | 0.80 | 01-MAY-05:40 | 926.59 | 18.52 | 0.00 | 418.17 | 413.94 | 22.41 | 250.83 | 373.67 |
June | 351.83 | 0.80 | 0.80 | 01-JUN-04:00 | 1028.76 | 19.64 | 29.00 | 410.33 | 447.19 | 23.45 | 264.83 | 376.17 |
July | 365.17 | 0.80 | 0.80 | 01-JUL-04:00 | 1033.92 | 18.58 | 0.00 | 419.83 | 446.06 | 23.09 | 271.67 | 377.17 |
August | 389.17 | 0.81 | 0.80 | 01-AUG-05:10 | 819.58 | 18.27 | 0.00 | 387.83 | 379.21 | 21.49 | 225.83 | 356.17 |
September | 285.33 | 0.81 | 0.80 | 01-SEP-05:00 | 618.25 | 17.45 | 0.00 | 334.17 | 302.12 | 20.70 | 53.67 | 271.67 |
October | 305.50 | 0.81 | 0.80 | 01-OCT-14:39 | 559.22 | 17.01 | 0.00 | 302.17 | 286.58 | 20.37 | 0.17 | 246.33 |
November | 240.83 | 0.81 | 0.80 | 01-NOV-06:00 | 488.27 | 15.75 | 0.00 | 248.83 | 228.94 | 19.07 | 0.00 | 156.17 |
December | 211.17 | 0.83 | 0.80 | 01-DEC-07:00 | 344.08 | 14.30 | 0.00 | 219.50 | 172.97 | 17.86 | 0.00 | 73.83 |
Annual Sum or Average | 3472.67 | 0.81 | 710.81 | 17.43 | 29.00 | 3902.50 | 329.62 | 20.99 | 1184.83 | 3046.67 | ||
Minimum of Months | 199.50 | 0.80 | 0.80 | 344.08 | 14.30 | 0.00 | 219.50 | 172.97 | 17.86 | 0.00 | 73.83 | |
Maximum of Months | 389.17 | 0.83 | 0.80 | 1033.92 | 19.64 | 29.00 | 419.83 | 447.19 | 23.45 | 271.67 | 377.17 |
Report: CoilReportMonthly
For: VAV WITH REHEAT HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.451206E+11 | 143711.29 | 19-JAN-22:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.419631E+11 | 141320.17 | 18-FEB-14:43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.257380E+11 | 148754.29 | 05-MAR-07:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.244793E+11 | 151315.44 | 13-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.743606E+10 | 122080.52 | 15-MAY-04:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.203912E+09 | 17085.42 | 01-JUN-13:47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 17396389.89 | 12585.75 | 11-JUL-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.257035E+09 | 30117.18 | 24-AUG-18:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.148309E+10 | 58663.17 | 24-SEP-05:34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.136507E+11 | 147684.13 | 26-OCT-23:27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.293646E+11 | 148235.34 | 13-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.189447E+11 | 139206.66 | 04-DEC-08:45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.208658E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 17396389.89 | 12585.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.451206E+11 | 151315.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: BASEMENT VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_1_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.320753E+10 | 2777.67 | 02-JAN-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.244292E+10 | 2717.04 | 06-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.156621E+10 | 2318.77 | 27-MAR-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.984444E+09 | 2482.26 | 20-APR-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.259192E+09 | 1801.97 | 04-MAY-04:48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 253567.20 | 82.65 | 07-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 50355134.29 | 1516.93 | 24-SEP-05:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.164643E+09 | 2071.10 | 27-OCT-06:59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.151000E+10 | 2410.80 | 14-NOV-20:31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.253822E+10 | 2346.44 | 25-DEC-05:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.127238E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.320753E+10 | 2777.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_2_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.195545E+09 | 844.70 | 15-JAN-11:36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.129595E+09 | 569.88 | 06-FEB-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 9127010.60 | 335.57 | 17-MAR-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 1913415.50 | 147.11 | 21-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 13295696.98 | 370.98 | 28-NOV-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 73974024.84 | 458.42 | 12-DEC-11:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.423450E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.195545E+09 | 844.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: MECH_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.143481E+10 | 1425.52 | 02-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.133579E+10 | 1415.59 | 01-FEB-16:47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.459499E+09 | 1311.31 | 23-MAR-16:47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 99413085.77 | 1166.15 | 03-APR-09:43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.344333E+09 | 910.04 | 24-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.876457E+09 | 1249.96 | 20-DEC-16:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.455031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.143481E+10 | 1425.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: STORAGE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.108559E+10 | 871.09 | 02-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.990224E+09 | 857.62 | 06-FEB-10:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.394866E+09 | 680.00 | 23-MAR-16:47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.108553E+09 | 650.80 | 03-APR-09:43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.306247E+09 | 1051.14 | 30-NOV-13:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.734203E+09 | 637.10 | 31-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.361969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.108559E+10 | 1051.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LAUNDRY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.392495E+09 | 4253.37 | 24-JAN-04:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.361369E+09 | 5526.79 | 18-FEB-16:28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.232537E+09 | 9144.40 | 28-MAR-02:38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.161947E+09 | 9299.21 | 29-APR-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 73965705.13 | 7185.86 | 17-MAY-03:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1810046.05 | 648.23 | 03-JUN-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 26780554.48 | 6336.44 | 30-SEP-03:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.112756E+09 | 9723.22 | 17-OCT-03:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.213916E+09 | 10466.88 | 09-NOV-02:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.300725E+09 | 3039.90 | 05-DEC-02:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.187830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.392495E+09 | 10466.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CAFE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.207649E+10 | 7394.74 | 15-JAN-11:36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109249E+10 | 5507.71 | 28-FEB-09:59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.543898E+09 | 6585.54 | 04-MAR-16:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.296553E+09 | 5046.89 | 21-APR-10:37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 39768712.39 | 1989.18 | 04-MAY-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 194643.02 | 269.98 | 26-SEP-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 3130999.69 | 927.68 | 31-OCT-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.449817E+09 | 4452.70 | 13-NOV-10:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130555E+10 | 4985.07 | 11-DEC-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.580789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.207649E+10 | 7394.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LOBBY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.111182E+10 | 10901.99 | 03-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.433842E+09 | 6668.21 | 27-FEB-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 25391456.53 | 3375.06 | 17-MAR-12:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 256935.62 | 284.84 | 21-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 28608658.17 | 5391.71 | 28-NOV-14:45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.344412E+09 | 6202.10 | 11-DEC-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.111182E+10 | 10901.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.803073E+10 | 9383.63 | 15-JAN-11:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.591123E+10 | 7887.56 | 01-FEB-17:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.159045E+10 | 5429.39 | 17-MAR-12:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.420387E+09 | 4835.37 | 21-APR-14:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.234427E+10 | 10993.31 | 30-NOV-13:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.553713E+10 | 7485.51 | 20-DEC-16:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.238342E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.803073E+10 | 10993.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.526884E+10 | 5200.17 | 02-JAN-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.441666E+10 | 5139.95 | 06-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.162138E+10 | 3271.57 | 23-MAR-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.483439E+09 | 3838.42 | 20-APR-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 18901321.62 | 1126.83 | 29-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.170120E+10 | 3685.41 | 17-NOV-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.380499E+10 | 3824.23 | 20-DEC-16:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.173154E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.526884E+10 | 5200.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: BANQUET_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: DINING_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: KITCHEN_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 185941.57 | 619.81 | 02-OCT-02:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 286129.74 | 953.77 | 09-NOV-02:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 472071.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 286129.74 | 953.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.472799E+10 | 11056.22 | 02-JAN-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.483628E+10 | 12245.64 | 06-FEB-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.539191E+09 | 4390.40 | 23-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 3170.73 | 0.39 | 25-APR-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17171.13 | 0.39 | 26-MAY-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 21241.03 | 0.39 | 27-JUN-10:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 12464.12 | 0.39 | 20-JUL-04:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 21984.90 | 10.44 | 09-AUG-04:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16076.36 | 0.39 | 18-SEP-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 23495.34 | 27.40 | 21-OCT-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.434607E+09 | 4401.19 | 24-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.903161E+09 | 7377.47 | 31-DEC-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.114414E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 3170.73 | 0.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.483628E+10 | 12245.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.576450E+10 | 11205.43 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.475345E+10 | 11204.63 | 07-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.237140E+10 | 11022.52 | 22-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.106289E+10 | 10753.64 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 92758382.52 | 3608.33 | 29-MAY-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4088106.50 | 3447.62 | 22-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3811446.45 | 2361.73 | 27-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 3871087.06 | 2356.11 | 06-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13068211.19 | 2901.89 | 23-SEP-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.216190E+09 | 6043.23 | 27-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.265947E+10 | 11011.29 | 25-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.462215E+10 | 11165.90 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.215676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 3811446.45 | 2356.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.576450E+10 | 11205.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.678757E+10 | 11158.53 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.601679E+10 | 11157.72 | 07-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.301119E+10 | 11013.99 | 22-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.124510E+10 | 10724.03 | 03-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.100954E+09 | 3506.63 | 30-MAY-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4062819.51 | 3617.68 | 04-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3391247.41 | 2559.94 | 27-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4105766.73 | 2524.61 | 10-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 17921684.15 | 3187.91 | 23-SEP-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.426075E+09 | 10541.51 | 29-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.342057E+10 | 11012.41 | 24-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.570195E+10 | 11119.07 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.267397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 3391247.41 | 2524.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.678757E+10 | 11158.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.946168E+10 | 21751.32 | 02-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.307108E+10 | 18209.79 | 07-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.353112E+09 | 11005.35 | 01-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 32259049.39 | 2975.17 | 02-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.189859E+09 | 7092.45 | 29-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.401922E+10 | 16610.67 | 31-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.171272E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.946168E+10 | 21751.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.270395E+11 | 62538.11 | 14-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.262231E+11 | 62633.94 | 06-FEB-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.102586E+11 | 60815.13 | 17-MAR-15:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.223597E+10 | 59067.39 | 03-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 93418546.47 | 35491.48 | 03-MAY-15:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 26129771.42 | 20506.47 | 20-JUN-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 14763752.54 | 14904.89 | 14-JUL-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 30821307.55 | 21586.66 | 30-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 67119227.34 | 24503.28 | 24-SEP-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.903567E+09 | 41247.86 | 21-OCT-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.955783E+10 | 60907.33 | 22-NOV-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.209892E+11 | 61840.73 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.974400E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 14763752.54 | 14904.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.270395E+11 | 62633.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.572446E+10 | 10939.10 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.464029E+10 | 10936.88 | 06-FEB-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.249591E+10 | 10758.87 | 17-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.106950E+10 | 10489.58 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.103131E+09 | 3169.36 | 05-MAY-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 2350812.79 | 2131.20 | 17-JUN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 902282.40 | 2304.59 | 31-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 311282.30 | 1668.41 | 06-AUG-18:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 11109487.82 | 2835.76 | 23-SEP-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.236540E+09 | 3721.80 | 31-OCT-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.251017E+10 | 10749.84 | 25-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455824E+10 | 10900.33 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.213529E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 311282.30 | 1668.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.572446E+10 | 10939.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.673488E+10 | 10891.37 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.587512E+10 | 10890.48 | 07-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.314864E+10 | 10712.08 | 17-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.123744E+10 | 10451.95 | 01-APR-15:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.115150E+09 | 3164.43 | 04-MAY-08:63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1876559.57 | 2166.57 | 17-JUN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 769852.61 | 2107.48 | 31-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 239544.80 | 1601.32 | 06-AUG-18:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13785499.77 | 2797.59 | 23-SEP-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.439918E+09 | 7351.56 | 31-OCT-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.316306E+10 | 10703.07 | 25-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.555806E+10 | 10852.76 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.262889E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 239544.80 | 1601.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.673488E+10 | 10891.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.197079E+10 | 3277.45 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.165315E+10 | 3277.20 | 07-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.881282E+09 | 3235.07 | 22-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.430090E+09 | 3173.15 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 60404155.30 | 1372.58 | 04-MAY-08:63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1233686.84 | 860.29 | 26-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1103788.24 | 645.82 | 01-JUL-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1031323.22 | 603.31 | 27-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13036108.62 | 971.66 | 23-SEP-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142036E+09 | 3091.24 | 27-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.991156E+09 | 3234.61 | 24-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.162046E+10 | 3265.78 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.776577E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 1031323.22 | 603.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.197079E+10 | 3277.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.228383E+10 | 3260.34 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.203379E+10 | 3260.06 | 07-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.108439E+10 | 3218.18 | 22-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.494085E+09 | 3158.88 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 65138126.88 | 1545.87 | 01-MAY-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1252861.82 | 851.76 | 22-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1056708.90 | 651.11 | 28-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1023943.93 | 603.96 | 27-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 20380275.78 | 980.46 | 23-SEP-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.244808E+09 | 3118.90 | 29-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.124466E+10 | 3217.73 | 24-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.195673E+10 | 3248.71 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.943114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 1023943.93 | 603.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.228383E+10 | 3260.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.606947E+10 | 15435.43 | 14-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.444326E+10 | 15432.67 | 06-FEB-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.249267E+10 | 15181.60 | 17-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.125425E+10 | 14778.94 | 21-APR-15:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.125537E+09 | 4104.38 | 03-MAY-15:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6951275.61 | 5518.95 | 22-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 5639929.80 | 4171.08 | 12-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4901540.46 | 4077.99 | 01-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 12725578.00 | 4218.73 | 23-SEP-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157324E+09 | 5139.45 | 27-OCT-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.220542E+10 | 14999.52 | 25-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.449028E+10 | 15286.09 | 31-DEC-19:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.212684E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 4901540.46 | 4077.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.606947E+10 | 15435.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.227956E+09 | 0.227956E+09 | 28016.06 | 12-JAN-22:44 | 28016.06 | 0.01 |
February | 0.00 | 0.00 | 0.207446E+09 | 0.207446E+09 | 14207.43 | 28-FEB-21:59 | 14207.43 | 0.00 |
March | 0.00 | 0.00 | 0.355282E+10 | 0.352241E+10 | 130064.22 | 27-MAR-16:00 | 130064.22 | 0.03 |
April | 0.00 | 0.00 | 0.341923E+11 | 0.339495E+11 | 210145.33 | 09-APR-10:50 | 140272.00 | 0.17 |
May | 0.00 | 0.00 | 0.126129E+12 | 0.108859E+12 | 291468.15 | 31-MAY-17:17 | 164536.86 | 0.39 |
June | 0.00 | 0.00 | 0.519220E+12 | 0.312368E+12 | 471839.16 | 24-JUN-17:12 | 175081.69 | 0.91 |
July | 0.00 | 0.00 | 0.817177E+12 | 0.447467E+12 | 489707.03 | 27-JUL-21:00 | 216083.01 | 1.00 |
August | 0.00 | 0.00 | 0.666890E+12 | 0.440176E+12 | 505719.26 | 11-AUG-22:00 | 216611.12 | 0.97 |
September | 0.00 | 0.00 | 0.362678E+12 | 0.251324E+12 | 479564.58 | 13-SEP-21:00 | 219979.68 | 0.80 |
October | 0.00 | 0.00 | 0.125687E+12 | 0.811245E+11 | 287726.08 | 05-OCT-19:10 | 145893.15 | 0.42 |
November | 0.00 | 0.00 | 0.359820E+10 | 0.330487E+10 | 63869.16 | 04-NOV-10:50 | 63869.16 | 0.03 |
December | 0.00 | 0.00 | 0.459344E+09 | 0.459344E+09 | 30701.03 | 03-DEC-20:45 | 30701.03 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.266002E+13 | 0.168299E+13 | 0.40 | |||
Minimum of Months | 0.00 | 0.00 | 0.207446E+09 | 0.207446E+09 | 14207.43 | 14207.43 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.817177E+12 | 0.447467E+12 | 505719.26 | 219979.68 | 1.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.697382E+09 | 0.589145E+09 | 32906.47 | 27-MAR-13:00 | 21433.80 | 0.02 |
April | 0.00 | 0.00 | 0.634269E+10 | 0.616737E+10 | 40374.02 | 09-APR-11:00 | 24738.55 | 0.13 |
May | 0.00 | 0.00 | 0.232123E+11 | 0.196119E+11 | 51821.69 | 31-MAY-17:06 | 27132.03 | 0.37 |
June | 0.00 | 0.00 | 0.961906E+11 | 0.555096E+11 | 79002.93 | 24-JUN-17:25 | 27247.14 | 0.91 |
July | 0.00 | 0.00 | 0.130865E+12 | 0.745834E+11 | 77079.99 | 23-JUL-14:20 | 28184.74 | 1.00 |
August | 0.00 | 0.00 | 0.107294E+12 | 0.710766E+11 | 73614.51 | 06-AUG-07:17 | 27093.61 | 0.99 |
September | 0.00 | 0.00 | 0.663363E+11 | 0.447544E+11 | 76059.89 | 22-SEP-17:30 | 26335.39 | 0.80 |
October | 0.00 | 0.00 | 0.245200E+11 | 0.147924E+11 | 52292.02 | 24-OCT-14:00 | 26086.26 | 0.41 |
November | 0.00 | 0.00 | 0.605095E+09 | 0.541138E+09 | 12351.77 | 10-NOV-08:00 | 4466.91 | 0.02 |
December | 0.00 | 0.00 | 2300.65 | 2300.65 | 34.51 | 04-DEC-21:10 | 34.51 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.456064E+12 | 0.287626E+12 | 0.39 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.130865E+12 | 0.745834E+11 | 79002.93 | 28184.74 | 1.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 42773173.65 | 41754485.90 | 13495.69 | 17-JAN-16:02 | 13495.69 | 0.00 |
February | 0.00 | 0.00 | 0.116071E+09 | 0.116007E+09 | 13498.30 | 20-FEB-16:02 | 13498.30 | 0.00 |
March | 0.00 | 0.00 | 0.814529E+09 | 0.756171E+09 | 14380.44 | 27-MAR-15:02 | 12847.47 | 0.03 |
April | 0.00 | 0.00 | 0.213957E+10 | 0.156050E+10 | 14069.37 | 10-APR-15:02 | 14069.37 | 0.28 |
May | 0.00 | 0.00 | 0.457448E+10 | 0.317833E+10 | 15534.62 | 18-MAY-15:02 | 11985.16 | 0.57 |
June | 0.00 | 0.00 | 0.901664E+10 | 0.535116E+10 | 18881.22 | 27-JUN-08:62 | 11210.03 | 0.87 |
July | 0.00 | 0.00 | 0.116257E+11 | 0.698409E+10 | 18931.26 | 30-JUL-08:62 | 11414.52 | 0.94 |
August | 0.00 | 0.00 | 0.122018E+11 | 0.801563E+10 | 18177.60 | 27-AUG-08:62 | 11571.14 | 0.95 |
September | 0.00 | 0.00 | 0.699127E+10 | 0.425074E+10 | 19228.94 | 22-SEP-18:02 | 9727.40 | 0.82 |
October | 0.00 | 0.00 | 0.448725E+10 | 0.286025E+10 | 16562.04 | 05-OCT-18:02 | 11905.22 | 0.51 |
November | 0.00 | 0.00 | 0.361447E+09 | 0.283646E+09 | 13696.27 | 03-NOV-15:02 | 13696.27 | 0.06 |
December | 0.00 | 0.00 | 50638906.34 | 50096024.44 | 13434.86 | 17-DEC-16:01 | 13434.86 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.524221E+11 | 0.334484E+11 | 0.42 | |||
Minimum of Months | 0.00 | 0.00 | 42773173.65 | 41754485.90 | 13434.86 | 9727.40 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.122018E+11 | 0.801563E+10 | 19228.94 | 14069.37 | 0.95 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 8835162.58 | 7858671.06 | 7460.77 | 17-JAN-16:02 | 7460.77 | 0.00 |
February | 0.00 | 0.00 | 18847774.53 | 18771190.86 | 12121.39 | 20-FEB-16:02 | 12121.39 | 0.00 |
March | 0.00 | 0.00 | 0.364371E+09 | 0.328886E+09 | 13522.11 | 27-MAR-15:02 | 11823.21 | 0.02 |
April | 0.00 | 0.00 | 0.147966E+10 | 0.104669E+10 | 13646.92 | 10-APR-15:02 | 13646.92 | 0.23 |
May | 0.00 | 0.00 | 0.409612E+10 | 0.280103E+10 | 15027.43 | 18-MAY-15:02 | 11544.83 | 0.54 |
June | 0.00 | 0.00 | 0.862299E+10 | 0.510424E+10 | 18286.21 | 27-JUN-08:62 | 10894.89 | 0.86 |
July | 0.00 | 0.00 | 0.110843E+11 | 0.659705E+10 | 18380.73 | 30-JUL-08:62 | 11065.20 | 0.94 |
August | 0.00 | 0.00 | 0.108497E+11 | 0.687075E+10 | 17679.79 | 27-AUG-08:62 | 11180.97 | 0.93 |
September | 0.00 | 0.00 | 0.547440E+10 | 0.306363E+10 | 18637.62 | 22-SEP-18:02 | 9401.07 | 0.76 |
October | 0.00 | 0.00 | 0.246441E+10 | 0.136717E+10 | 15492.37 | 05-OCT-18:02 | 11660.85 | 0.42 |
November | 0.00 | 0.00 | 80861084.93 | 66294791.70 | 13285.58 | 03-NOV-15:02 | 13285.58 | 0.02 |
December | 0.00 | 0.00 | 6128130.11 | 5630201.85 | 4554.49 | 17-DEC-19:03 | 4554.49 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.445506E+11 | 0.272780E+11 | 0.40 | |||
Minimum of Months | 0.00 | 0.00 | 6128130.11 | 5630201.85 | 4554.49 | 4554.49 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.110843E+11 | 0.687075E+10 | 18637.62 | 13646.92 | 0.94 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.123189E+09 | 0.123189E+09 | 7563.27 | 19-JAN-14:40 | 7563.27 | 0.00 |
February | 0.00 | 0.00 | 0.814508E+09 | 0.814508E+09 | 17093.77 | 20-FEB-13:23 | 17093.77 | 0.00 |
March | 0.00 | 0.00 | 0.258465E+10 | 0.257064E+10 | 30352.29 | 03-MAR-13:30 | 30352.29 | 0.00 |
April | 0.00 | 0.00 | 0.601189E+10 | 0.452566E+10 | 39540.94 | 08-APR-12:30 | 28743.49 | 0.10 |
May | 0.00 | 0.00 | 0.954621E+10 | 0.694827E+10 | 30973.35 | 31-MAY-12:30 | 21295.17 | 0.18 |
June | 0.00 | 0.00 | 0.213051E+11 | 0.996113E+10 | 35298.71 | 19-JUN-12:50 | 27004.51 | 0.60 |
July | 0.00 | 0.00 | 0.388565E+11 | 0.189783E+11 | 37812.58 | 08-JUL-12:10 | 29028.88 | 0.90 |
August | 0.00 | 0.00 | 0.478974E+11 | 0.285532E+11 | 45562.27 | 16-AUG-14:50 | 34718.07 | 0.93 |
September | 0.00 | 0.00 | 0.304814E+11 | 0.198099E+11 | 50077.34 | 30-SEP-12:30 | 44415.70 | 0.61 |
October | 0.00 | 0.00 | 0.305560E+11 | 0.239748E+11 | 54513.71 | 04-OCT-12:00 | 46026.32 | 0.36 |
November | 0.00 | 0.00 | 0.557547E+10 | 0.532256E+10 | 43745.13 | 02-NOV-12:50 | 43745.13 | 0.03 |
December | 0.00 | 0.00 | 0.214862E+10 | 0.214862E+10 | 30820.04 | 17-DEC-13:40 | 30820.04 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.195901E+12 | 0.123731E+12 | 0.31 | |||
Minimum of Months | 0.00 | 0.00 | 0.123189E+09 | 0.123189E+09 | 7563.27 | 7563.27 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.478974E+11 | 0.285532E+11 | 54513.71 | 46026.32 | 0.93 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.120826E+09 | 79896470.38 | 43724.31 | 03-JAN-19:03 | 41427.88 | 0.01 |
February | 0.00 | 0.00 | 54776754.09 | 54776754.09 | 40768.03 | 01-FEB-19:03 | 40768.03 | 0.00 |
March | 0.00 | 0.00 | 0.152831E+10 | 0.109903E+10 | 62586.23 | 28-MAR-18:02 | 62586.23 | 0.06 |
April | 0.00 | 0.00 | 0.999686E+10 | 0.625558E+10 | 68282.57 | 08-APR-15:02 | 68282.57 | 0.31 |
May | 0.00 | 0.00 | 0.298417E+11 | 0.203196E+11 | 81769.96 | 31-MAY-18:02 | 64240.13 | 0.53 |
June | 0.00 | 0.00 | 0.529524E+11 | 0.325324E+11 | 100007.38 | 27-JUN-08:62 | 53472.40 | 0.69 |
July | 0.00 | 0.00 | 0.668572E+11 | 0.426349E+11 | 100848.22 | 30-JUL-08:62 | 56911.29 | 0.76 |
August | 0.00 | 0.00 | 0.585720E+11 | 0.378434E+11 | 95871.55 | 06-AUG-08:62 | 55533.04 | 0.74 |
September | 0.00 | 0.00 | 0.353832E+11 | 0.201302E+11 | 102790.43 | 22-SEP-18:02 | 47483.79 | 0.66 |
October | 0.00 | 0.00 | 0.151273E+11 | 0.750615E+10 | 80764.54 | 05-OCT-18:02 | 54874.23 | 0.43 |
November | 0.00 | 0.00 | 0.215206E+10 | 0.133799E+10 | 63042.10 | 05-NOV-08:62 | 63042.10 | 0.12 |
December | 0.00 | 0.00 | 0.116948E+09 | 0.107466E+09 | 31687.95 | 29-DEC-19:04 | 31687.95 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.272704E+12 | 0.169901E+12 | 0.36 | |||
Minimum of Months | 0.00 | 0.00 | 54776754.09 | 54776754.09 | 31687.95 | 31687.95 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.668572E+11 | 0.426349E+11 | 102790.43 | 68282.57 | 0.76 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 81009770.63 | 80064473.08 | 10932.81 | 19-JAN-09:01 | 10932.81 | 0.00 |
February | 0.00 | 0.00 | 0.127168E+09 | 0.127112E+09 | 11864.33 | 25-FEB-09:01 | 11864.33 | 0.00 |
March | 0.00 | 0.00 | 0.671305E+09 | 0.634803E+09 | 12622.56 | 27-MAR-15:02 | 10929.56 | 0.03 |
April | 0.00 | 0.00 | 0.215556E+10 | 0.153309E+10 | 12845.27 | 10-APR-15:02 | 12845.27 | 0.30 |
May | 0.00 | 0.00 | 0.477714E+10 | 0.337386E+10 | 14480.16 | 31-MAY-18:02 | 11607.36 | 0.58 |
June | 0.00 | 0.00 | 0.849075E+10 | 0.496273E+10 | 16811.57 | 21-JUN-18:02 | 10336.13 | 0.88 |
July | 0.00 | 0.00 | 0.114733E+11 | 0.686222E+10 | 17021.36 | 30-JUL-08:62 | 10589.57 | 0.96 |
August | 0.00 | 0.00 | 0.120791E+11 | 0.790925E+10 | 16208.78 | 06-AUG-08:62 | 10626.52 | 0.97 |
September | 0.00 | 0.00 | 0.706971E+10 | 0.433513E+10 | 17558.22 | 22-SEP-18:02 | 8828.46 | 0.85 |
October | 0.00 | 0.00 | 0.429773E+10 | 0.271408E+10 | 14997.85 | 05-OCT-18:02 | 10621.22 | 0.52 |
November | 0.00 | 0.00 | 0.535234E+09 | 0.437506E+09 | 12504.88 | 03-NOV-15:02 | 12504.88 | 0.07 |
December | 0.00 | 0.00 | 0.145900E+09 | 0.141820E+09 | 11794.94 | 17-DEC-09:01 | 11794.94 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.519039E+11 | 0.331117E+11 | 0.43 | |||
Minimum of Months | 0.00 | 0.00 | 81009770.63 | 80064473.08 | 10932.81 | 8828.46 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.120791E+11 | 0.790925E+10 | 17558.22 | 12845.27 | 0.97 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 9518493.76 | 8663992.49 | 4711.70 | 24-JAN-19:04 | 3527.17 | 0.00 |
February | 0.00 | 0.00 | 18186644.54 | 18156523.46 | 9493.41 | 19-FEB-09:01 | 9493.41 | 0.00 |
March | 0.00 | 0.00 | 0.252296E+09 | 0.233750E+09 | 11981.71 | 03-MAR-09:02 | 11981.71 | 0.01 |
April | 0.00 | 0.00 | 0.144536E+10 | 0.990257E+09 | 12482.92 | 09-APR-15:02 | 11365.85 | 0.26 |
May | 0.00 | 0.00 | 0.425831E+10 | 0.295713E+10 | 13857.10 | 18-MAY-15:02 | 10772.05 | 0.57 |
June | 0.00 | 0.00 | 0.807934E+10 | 0.470656E+10 | 16302.50 | 21-JUN-18:02 | 10060.84 | 0.88 |
July | 0.00 | 0.00 | 0.109252E+11 | 0.644854E+10 | 16557.90 | 30-JUL-08:62 | 10275.97 | 0.96 |
August | 0.00 | 0.00 | 0.107131E+11 | 0.667766E+10 | 16142.21 | 06-AUG-08:62 | 10057.23 | 0.96 |
September | 0.00 | 0.00 | 0.550850E+10 | 0.313846E+10 | 17043.29 | 22-SEP-18:02 | 8545.81 | 0.81 |
October | 0.00 | 0.00 | 0.223169E+10 | 0.123375E+10 | 14776.48 | 25-OCT-08:62 | 10382.15 | 0.41 |
November | 0.00 | 0.00 | 0.157155E+09 | 0.116888E+09 | 10946.07 | 06-NOV-09:02 | 10946.07 | 0.03 |
December | 0.00 | 0.00 | 11629740.17 | 11261315.91 | 3902.90 | 09-DEC-09:03 | 3902.90 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.436103E+11 | 0.265411E+11 | 0.41 | |||
Minimum of Months | 0.00 | 0.00 | 9518493.76 | 8663992.49 | 3902.90 | 3527.17 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.109252E+11 | 0.667766E+10 | 17043.29 | 11981.71 | 0.96 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 11597952.98 | 11282813.33 | 3541.01 | 17-JAN-16:02 | 3541.01 | 0.00 |
February | 0.00 | 0.00 | 29898443.97 | 29859265.87 | 3541.70 | 20-FEB-16:02 | 3541.70 | 0.00 |
March | 0.00 | 0.00 | 0.203734E+09 | 0.189028E+09 | 3797.28 | 27-MAR-15:02 | 3410.93 | 0.03 |
April | 0.00 | 0.00 | 0.526167E+09 | 0.397838E+09 | 3691.48 | 10-APR-15:02 | 3691.48 | 0.24 |
May | 0.00 | 0.00 | 0.111371E+10 | 0.803077E+09 | 4143.73 | 31-MAY-08:62 | 3420.42 | 0.51 |
June | 0.00 | 0.00 | 0.225745E+10 | 0.133289E+10 | 5142.55 | 27-JUN-08:62 | 2824.25 | 0.87 |
July | 0.00 | 0.00 | 0.297448E+10 | 0.177382E+10 | 5192.21 | 30-JUL-08:62 | 2855.64 | 0.94 |
August | 0.00 | 0.00 | 0.309870E+10 | 0.201853E+10 | 4981.70 | 27-AUG-08:62 | 2865.99 | 0.94 |
September | 0.00 | 0.00 | 0.167196E+10 | 0.101370E+10 | 5217.02 | 22-SEP-18:02 | 2393.82 | 0.77 |
October | 0.00 | 0.00 | 0.990745E+09 | 0.636464E+09 | 4433.72 | 05-OCT-18:02 | 3071.32 | 0.44 |
November | 0.00 | 0.00 | 67547344.21 | 55227836.72 | 3593.58 | 03-NOV-15:02 | 3593.58 | 0.04 |
December | 0.00 | 0.00 | 11437305.67 | 11281907.28 | 3540.21 | 17-DEC-16:01 | 3540.21 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.129574E+11 | 0.827300E+10 | 0.40 | |||
Minimum of Months | 0.00 | 0.00 | 11437305.67 | 11281907.28 | 3540.21 | 2393.82 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.309870E+10 | 0.201853E+10 | 5217.02 | 3691.48 | 0.94 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 2828151.59 | 2527977.89 | 1134.88 | 23-JAN-19:04 | 776.64 | 0.00 |
February | 0.00 | 0.00 | 3468788.35 | 3432166.88 | 2467.47 | 20-FEB-16:02 | 2467.47 | 0.00 |
March | 0.00 | 0.00 | 84507225.04 | 75442682.21 | 3546.50 | 27-MAR-15:02 | 3107.72 | 0.02 |
April | 0.00 | 0.00 | 0.356736E+09 | 0.263281E+09 | 3591.99 | 16-APR-18:02 | 3591.99 | 0.19 |
May | 0.00 | 0.00 | 0.985549E+09 | 0.700930E+09 | 3989.40 | 31-MAY-08:62 | 3323.86 | 0.48 |
June | 0.00 | 0.00 | 0.215412E+10 | 0.126552E+10 | 4973.87 | 27-JUN-08:62 | 2737.53 | 0.86 |
July | 0.00 | 0.00 | 0.283332E+10 | 0.166990E+10 | 5030.61 | 30-JUL-08:62 | 2762.36 | 0.94 |
August | 0.00 | 0.00 | 0.274168E+10 | 0.172027E+10 | 4813.87 | 27-AUG-08:62 | 2733.15 | 0.93 |
September | 0.00 | 0.00 | 0.127207E+10 | 0.709840E+09 | 5046.91 | 22-SEP-18:02 | 2306.91 | 0.69 |
October | 0.00 | 0.00 | 0.495607E+09 | 0.285122E+09 | 4141.58 | 05-OCT-18:02 | 3009.11 | 0.32 |
November | 0.00 | 0.00 | 14855461.42 | 13146505.72 | 3449.67 | 03-NOV-15:02 | 3449.67 | 0.01 |
December | 0.00 | 0.00 | 3176098.86 | 3040947.07 | 1115.01 | 08-DEC-16:03 | 1115.01 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.109479E+11 | 0.671245E+10 | 0.37 | |||
Minimum of Months | 0.00 | 0.00 | 2828151.59 | 2527977.89 | 1115.01 | 776.64 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.283332E+10 | 0.172027E+10 | 5046.91 | 3591.99 | 0.94 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.876715E+09 | 0.875637E+09 | 16313.45 | 17-JAN-16:02 | 16313.45 | 0.00 |
February | 0.00 | 0.00 | 0.129096E+10 | 0.129081E+10 | 16316.88 | 20-FEB-16:02 | 16316.88 | 0.00 |
March | 0.00 | 0.00 | 0.244458E+10 | 0.230192E+10 | 17177.87 | 27-MAR-15:02 | 16008.76 | 0.06 |
April | 0.00 | 0.00 | 0.347770E+10 | 0.260216E+10 | 17004.97 | 10-APR-15:02 | 17004.97 | 0.31 |
May | 0.00 | 0.00 | 0.548088E+10 | 0.370435E+10 | 20114.29 | 31-MAY-18:02 | 14833.04 | 0.57 |
June | 0.00 | 0.00 | 0.105766E+11 | 0.583795E+10 | 24173.56 | 27-JUN-08:62 | 12540.46 | 0.85 |
July | 0.00 | 0.00 | 0.146900E+11 | 0.863362E+10 | 24194.19 | 30-JUL-08:62 | 13035.45 | 0.93 |
August | 0.00 | 0.00 | 0.160992E+11 | 0.105282E+11 | 23130.48 | 27-AUG-08:62 | 13317.41 | 0.94 |
September | 0.00 | 0.00 | 0.112189E+11 | 0.726285E+10 | 24643.94 | 22-SEP-18:02 | 10937.57 | 0.84 |
October | 0.00 | 0.00 | 0.982079E+10 | 0.724863E+10 | 20732.55 | 05-OCT-18:02 | 13726.95 | 0.55 |
November | 0.00 | 0.00 | 0.227208E+10 | 0.197977E+10 | 16554.48 | 03-NOV-15:02 | 16554.48 | 0.13 |
December | 0.00 | 0.00 | 0.156237E+10 | 0.155626E+10 | 16312.71 | 03-DEC-16:02 | 16312.71 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.798107E+11 | 0.538221E+11 | 0.43 | |||
Minimum of Months | 0.00 | 0.00 | 0.876715E+09 | 0.875637E+09 | 16312.71 | 10937.57 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.160992E+11 | 0.105282E+11 | 24643.94 | 17004.97 | 0.94 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 53377.77 | 244134.17 | 02-JAN-09:03 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 50165.40 | 250248.53 | 06-FEB-09:01 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 21699.48 | 188916.36 | 31-MAR-15:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 13755.62 | 179631.66 | 21-APR-15:01 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 3163.56 | 121348.43 | 15-MAY-02:45 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 100.39 | 42838.50 | 06-JUN-15:05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 21.57 | 22033.06 | 14-JUL-08:07 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 111.42 | 43179.12 | 30-AUG-08:05 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 650.26 | 58380.05 | 24-SEP-05:16 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 6170.83 | 141585.99 | 26-OCT-23:27 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 23888.13 | 203416.42 | 27-NOV-16:01 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 32800.61 | 192608.75 | 04-DEC-19:01 |
Annual Sum or Average | 0.00 | 16970.32 | ||||
Minimum of Months | 0.00 | 0.00 | 21.57 | 22033.06 | ||
Maximum of Months | 0.00 | 0.00 | 53377.77 | 250248.53 |
Report: PlantLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 1928.75 | 48858.99 | 13-JAN-09:04 | 0.00 | 0.00 | 01-JAN-00:03 |
February | 2686.08 | 52898.63 | 16-FEB-09:04 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 7209.57 | 242235.07 | 27-MAR-15:02 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 29509.56 | 384848.35 | 07-APR-15:03 | 0.00 | 0.00 | 01-APR-00:10 |
May | 84419.21 | 519182.81 | 31-MAY-18:03 | 0.00 | 0.00 | 01-MAY-00:05 |
June | 289886.33 | 753327.34 | 24-JUN-18:03 | 0.00 | 0.00 | 01-JUN-00:05 |
July | 422855.05 | 716524.30 | 14-JUL-18:03 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 359016.28 | 698936.02 | 04-AUG-18:03 | 0.00 | 0.00 | 01-AUG-00:05 |
September | 210820.64 | 659088.70 | 22-SEP-18:02 | 0.00 | 0.00 | 01-SEP-00:05 |
October | 86716.27 | 493398.93 | 05-OCT-15:03 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 8398.10 | 138801.50 | 04-NOV-15:01 | 0.00 | 0.00 | 01-NOV-00:05 |
December | 3627.31 | 58343.85 | 17-DEC-16:04 | 0.00 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 126500.26 | 0.00 | ||||
Minimum of Months | 1928.75 | 48858.99 | 0.00 | 0.00 | ||
Maximum of Months | 422855.05 | 753327.34 | 0.00 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 28260.05 | 61840.28 | 24-JAN-07:20 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 28541.20 | 64221.49 | 16-FEB-18:41 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 27934.38 | 65211.05 | 26-MAR-07:41 |
April | 0.00 | 0.00 | 01-APR-00:10 | 26541.77 | 64141.31 | 13-APR-06:21 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 24818.45 | 56873.09 | 02-MAY-06:05 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 23174.66 | 48133.40 | 01-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22020.11 | 44991.42 | 03-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 21739.19 | 45215.16 | 22-AUG-06:50 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 22357.33 | 49893.27 | 20-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 23700.37 | 56813.64 | 27-OCT-20:11 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 25447.27 | 59097.62 | 27-NOV-07:19 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 27134.22 | 64015.78 | 26-DEC-21:31 |
Annual Sum or Average | 0.00 | 25119.44 | ||||
Minimum of Months | 0.00 | 0.00 | 21739.19 | 44991.42 | ||
Maximum of Months | 0.00 | 0.00 | 28541.20 | 65211.05 |
Report: FanReportMonthly
For: FLR_3_DOAS FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.587890E+10 | 0.88 | 2194.93 | 01-JAN-00:03 | 0.88 |
February | 0.530997E+10 | 0.88 | 2194.93 | 01-FEB-00:03 | 0.88 |
March | 0.587890E+10 | 0.88 | 2194.93 | 01-MAR-00:03 | 0.88 |
April | 0.568926E+10 | 0.88 | 2194.93 | 01-APR-00:10 | 0.87 |
May | 0.587890E+10 | 0.87 | 2194.93 | 01-MAY-00:05 | 0.87 |
June | 0.568926E+10 | 0.87 | 2194.93 | 01-JUN-00:05 | 0.87 |
July | 0.587890E+10 | 0.87 | 2194.93 | 01-JUL-00:10 | 0.87 |
August | 0.587890E+10 | 0.87 | 2194.93 | 01-AUG-00:05 | 0.87 |
September | 0.568926E+10 | 0.87 | 2194.93 | 01-SEP-00:05 | 0.87 |
October | 0.587890E+10 | 0.87 | 2194.93 | 01-OCT-00:10 | 0.87 |
November | 0.568926E+10 | 0.88 | 2194.93 | 01-NOV-00:05 | 0.87 |
December | 0.587890E+10 | 0.88 | 2194.93 | 01-DEC-00:03 | 0.88 |
Annual Sum or Average | 0.692193E+11 | 0.87 | |||
Minimum of Months | 0.530997E+10 | 0.87 | 2194.93 | 0.87 | |
Maximum of Months | 0.587890E+10 | 0.88 | 2194.93 | 0.88 |
Report: FanReportMonthly
For: VAV WITH REHEAT FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.330328E+11 | 0.79 | 40971.51 | 19-JAN-20:05 | 1.64 |
February | 0.295480E+11 | 0.79 | 26933.30 | 01-FEB-19:37 | 1.26 |
March | 0.348413E+11 | 0.82 | 34865.54 | 03-MAR-05:45 | 1.47 |
April | 0.345567E+11 | 0.83 | 35417.67 | 11-APR-21:48 | 1.50 |
May | 0.370209E+11 | 0.84 | 34865.54 | 16-MAY-04:35 | 1.47 |
June | 0.380460E+11 | 0.87 | 28658.33 | 20-JUN-21:10 | 1.29 |
July | 0.409099E+11 | 0.88 | 30354.91 | 10-JUL-21:10 | 1.34 |
August | 0.422116E+11 | 0.90 | 34811.66 | 22-AUG-19:00 | 1.47 |
September | 0.382746E+11 | 0.87 | 33648.52 | 07-SEP-21:10 | 1.43 |
October | 0.384278E+11 | 0.86 | 40971.51 | 07-OCT-22:33 | 1.64 |
November | 0.351837E+11 | 0.83 | 40971.51 | 05-NOV-21:55 | 1.63 |
December | 0.340181E+11 | 0.81 | 39971.55 | 17-DEC-22:12 | 1.61 |
Annual Sum or Average | 0.436071E+12 | 0.84 | |||
Minimum of Months | 0.295480E+11 | 0.79 | 26933.30 | 1.26 | |
Maximum of Months | 0.422116E+11 | 0.90 | 40971.51 | 1.64 |
Report: FanReportMonthly
For: LAUNDRY_FLR_1 EXHAUST FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.205205E+09 | 0.27 | 76.61 | 01-JAN-00:03 | 0.27 |
February | 0.185347E+09 | 0.27 | 76.61 | 01-FEB-00:03 | 0.27 |
March | 0.205205E+09 | 0.27 | 76.61 | 01-MAR-00:03 | 0.27 |
April | 0.198586E+09 | 0.27 | 76.61 | 01-APR-00:10 | 0.27 |
May | 0.205205E+09 | 0.26 | 76.61 | 01-MAY-00:05 | 0.26 |
June | 0.198586E+09 | 0.26 | 76.61 | 01-JUN-00:05 | 0.26 |
July | 0.205205E+09 | 0.26 | 76.61 | 01-JUL-00:10 | 0.26 |
August | 0.205205E+09 | 0.26 | 76.61 | 01-AUG-00:05 | 0.26 |
September | 0.198586E+09 | 0.26 | 76.61 | 01-SEP-00:05 | 0.26 |
October | 0.205205E+09 | 0.26 | 76.61 | 01-OCT-00:10 | 0.26 |
November | 0.198586E+09 | 0.27 | 76.61 | 01-NOV-00:05 | 0.27 |
December | 0.205205E+09 | 0.27 | 76.61 | 01-DEC-00:03 | 0.27 |
Annual Sum or Average | 0.241613E+10 | 0.27 | |||
Minimum of Months | 0.185347E+09 | 0.26 | 76.61 | 0.26 | |
Maximum of Months | 0.205205E+09 | 0.27 | 76.61 | 0.27 |
Report: FanReportMonthly
For: LOBBY_FLR_1 EXHAUST FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:05 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: BANQUET_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | -0.0 | 0.00 | 01-JAN-00:03 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | -0.0 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | -0.0 | 0.00 | 01-JUN-00:05 | 0.00 |
July | 0.00 | -0.0 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | -0.0 | 0.00 | 01-AUG-00:05 | 0.00 |
September | 0.00 | -0.0 | 0.00 | 01-SEP-00:05 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | -0.0 | 0.00 | 01-NOV-00:05 | 0.00 |
December | 0.00 | -0.0 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | -0.0 | |||
Minimum of Months | 0.00 | -0.0 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: DINING_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | -0.0 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | -0.0 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:05 | 0.00 |
July | 0.00 | -0.0 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | -0.0 | 0.00 | 01-AUG-00:05 | 0.00 |
September | 0.00 | -0.0 | 0.00 | 01-SEP-00:05 | 0.00 |
October | 0.00 | -0.0 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | -0.0 | 0.00 | 01-NOV-00:05 | 0.00 |
December | 0.00 | -0.0 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | -0.0 | |||
Minimum of Months | 0.00 | -0.0 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: KITCHEN_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.116283E+10 | 0.19 | 612.92 | 01-JAN-07:03 | 0.27 |
February | 0.105030E+10 | 0.19 | 612.92 | 01-FEB-07:05 | 0.27 |
March | 0.116283E+10 | 0.19 | 612.92 | 01-MAR-07:05 | 0.27 |
April | 0.112532E+10 | 0.19 | 612.92 | 01-APR-06:05 | 0.27 |
May | 0.116283E+10 | 0.19 | 612.92 | 01-MAY-06:05 | 0.27 |
June | 0.112532E+10 | 0.19 | 612.92 | 01-JUN-06:05 | 0.26 |
July | 0.116283E+10 | 0.19 | 612.92 | 01-JUL-06:10 | 0.26 |
August | 0.116283E+10 | 0.19 | 612.92 | 01-AUG-06:05 | 0.26 |
September | 0.112532E+10 | 0.19 | 612.92 | 01-SEP-06:05 | 0.26 |
October | 0.116283E+10 | 0.19 | 612.92 | 01-OCT-06:05 | 0.26 |
November | 0.112532E+10 | 0.19 | 612.92 | 01-NOV-06:05 | 0.27 |
December | 0.116283E+10 | 0.19 | 612.92 | 01-DEC-07:05 | 0.27 |
Annual Sum or Average | 0.136914E+11 | 0.19 | |||
Minimum of Months | 0.105030E+10 | 0.19 | 612.92 | 0.26 | |
Maximum of Months | 0.116283E+10 | 0.19 | 612.92 | 0.27 |
Report: FanReportMonthly
For: ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.286554E+09 | 0.46 | 801.85 | 01-JAN-09:01 | 0.58 |
February | 0.244233E+09 | 0.45 | 801.85 | 01-FEB-09:01 | 0.58 |
March | 0.196903E+09 | 0.43 | 801.85 | 01-MAR-16:02 | 0.58 |
April | 0.207127E+09 | 0.45 | 801.85 | 01-APR-08:61 | 0.58 |
May | 0.285804E+09 | 0.48 | 801.85 | 01-MAY-15:02 | 0.58 |
June | 0.442531E+09 | 0.52 | 801.85 | 01-JUN-08:62 | 0.57 |
July | 0.528957E+09 | 0.54 | 801.85 | 01-JUL-08:61 | 0.57 |
August | 0.583747E+09 | 0.54 | 801.85 | 01-AUG-08:62 | 0.57 |
September | 0.360539E+09 | 0.51 | 801.85 | 01-SEP-08:61 | 0.57 |
October | 0.269247E+09 | 0.49 | 801.85 | 02-OCT-15:02 | 0.57 |
November | 0.180695E+09 | 0.42 | 801.85 | 01-NOV-15:02 | 0.58 |
December | 0.248017E+09 | 0.45 | 801.85 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.383435E+10 | 0.48 | |||
Minimum of Months | 0.180695E+09 | 0.42 | 801.85 | 0.57 | |
Maximum of Months | 0.583747E+09 | 0.54 | 801.85 | 0.58 |
Report: FanReportMonthly
For: ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.316879E+09 | 0.49 | 777.29 | 01-JAN-09:01 | 0.58 |
February | 0.280634E+09 | 0.48 | 777.29 | 01-FEB-09:01 | 0.58 |
March | 0.194500E+09 | 0.42 | 777.29 | 01-MAR-09:02 | 0.58 |
April | 0.176201E+09 | 0.43 | 777.29 | 01-APR-08:61 | 0.58 |
May | 0.259316E+09 | 0.46 | 777.29 | 01-MAY-15:02 | 0.58 |
June | 0.424471E+09 | 0.52 | 777.29 | 01-JUN-08:62 | 0.57 |
July | 0.505386E+09 | 0.54 | 777.29 | 01-JUL-08:61 | 0.57 |
August | 0.517864E+09 | 0.53 | 777.29 | 01-AUG-08:62 | 0.57 |
September | 0.287011E+09 | 0.48 | 777.29 | 01-SEP-08:61 | 0.57 |
October | 0.176325E+09 | 0.44 | 777.29 | 02-OCT-15:02 | 0.57 |
November | 0.193698E+09 | 0.43 | 777.29 | 01-NOV-08:62 | 0.57 |
December | 0.282895E+09 | 0.47 | 777.29 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.361518E+10 | 0.47 | |||
Minimum of Months | 0.176201E+09 | 0.42 | 777.29 | 0.57 | |
Maximum of Months | 0.517864E+09 | 0.54 | 777.29 | 0.58 |
Report: FanReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.569275E+09 | 0.26 | 932.55 | 02-JAN-05:00 | 0.58 |
February | 0.243677E+09 | 0.13 | 893.11 | 20-FEB-13:23 | 0.58 |
March | 0.172239E+09 | 0.07 | 1384.36 | 03-MAR-13:30 | 0.58 |
April | 0.324906E+09 | 0.11 | 2265.19 | 07-APR-12:30 | 0.57 |
May | 0.525645E+09 | 0.21 | 1226.89 | 30-MAY-12:50 | 0.57 |
June | 0.957813E+09 | 0.36 | 1321.56 | 19-JUN-13:20 | 0.57 |
July | 0.161190E+10 | 0.51 | 1394.76 | 10-JUL-13:10 | 0.57 |
August | 0.210864E+10 | 0.54 | 2538.91 | 30-AUG-13:30 | 0.57 |
September | 0.148210E+10 | 0.40 | 4090.13 | 30-SEP-12:40 | 0.57 |
October | 0.156828E+10 | 0.34 | 2711.78 | 10-OCT-12:30 | 0.57 |
November | 0.327154E+09 | 0.10 | 2527.60 | 04-NOV-13:10 | 0.57 |
December | 0.380092E+09 | 0.17 | 1402.48 | 17-DEC-13:40 | 0.58 |
Annual Sum or Average | 0.102717E+11 | 0.27 | |||
Minimum of Months | 0.172239E+09 | 0.07 | 893.11 | 0.57 | |
Maximum of Months | 0.210864E+10 | 0.54 | 4090.13 | 0.58 |
Report: FanReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.129288E+10 | 0.42 | 4053.44 | 01-JAN-09:01 | 0.58 |
February | 0.122228E+10 | 0.42 | 4053.44 | 01-FEB-09:01 | 0.58 |
March | 0.741043E+09 | 0.41 | 4053.44 | 03-MAR-19:02 | 0.58 |
April | 0.793457E+09 | 0.41 | 4053.44 | 01-APR-15:01 | 0.58 |
May | 0.160793E+10 | 0.41 | 4053.44 | 01-MAY-08:62 | 0.57 |
June | 0.245583E+10 | 0.41 | 4053.44 | 01-JUN-08:62 | 0.57 |
July | 0.303970E+10 | 0.43 | 4053.44 | 01-JUL-08:61 | 0.57 |
August | 0.274548E+10 | 0.43 | 4053.44 | 01-AUG-08:62 | 0.57 |
September | 0.168155E+10 | 0.41 | 4053.44 | 01-SEP-08:61 | 0.57 |
October | 0.890382E+09 | 0.41 | 4053.44 | 01-OCT-08:62 | 0.57 |
November | 0.717819E+09 | 0.41 | 4053.44 | 04-NOV-08:62 | 0.57 |
December | 0.110217E+10 | 0.41 | 4053.44 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.182905E+11 | 0.41 | |||
Minimum of Months | 0.717819E+09 | 0.41 | 4053.44 | 0.57 | |
Maximum of Months | 0.303970E+10 | 0.43 | 4053.44 | 0.58 |
Report: FanReportMonthly
For: ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.268632E+09 | 0.46 | 730.51 | 01-JAN-09:01 | 0.58 |
February | 0.224295E+09 | 0.44 | 730.51 | 01-FEB-16:01 | 0.58 |
March | 0.183734E+09 | 0.43 | 730.51 | 01-MAR-09:02 | 0.58 |
April | 0.201627E+09 | 0.46 | 730.51 | 01-APR-08:61 | 0.58 |
May | 0.294735E+09 | 0.50 | 730.51 | 01-MAY-08:62 | 0.57 |
June | 0.413060E+09 | 0.53 | 730.51 | 01-JUN-08:62 | 0.57 |
July | 0.519759E+09 | 0.55 | 730.51 | 01-JUL-08:61 | 0.57 |
August | 0.574504E+09 | 0.56 | 730.51 | 01-AUG-08:62 | 0.57 |
September | 0.365822E+09 | 0.52 | 730.51 | 01-SEP-08:61 | 0.57 |
October | 0.259124E+09 | 0.50 | 730.51 | 02-OCT-08:62 | 0.57 |
November | 0.173277E+09 | 0.42 | 730.51 | 01-NOV-08:62 | 0.57 |
December | 0.234512E+09 | 0.44 | 730.51 | 01-DEC-16:01 | 0.58 |
Annual Sum or Average | 0.371308E+10 | 0.48 | |||
Minimum of Months | 0.173277E+09 | 0.42 | 730.51 | 0.57 | |
Maximum of Months | 0.574504E+09 | 0.56 | 730.51 | 0.58 |
Report: FanReportMonthly
For: ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.297225E+09 | 0.50 | 709.14 | 01-JAN-09:01 | 0.58 |
February | 0.259299E+09 | 0.48 | 709.14 | 01-FEB-09:01 | 0.58 |
March | 0.182801E+09 | 0.42 | 709.14 | 01-MAR-09:02 | 0.58 |
April | 0.167247E+09 | 0.43 | 709.14 | 01-APR-08:61 | 0.58 |
May | 0.266901E+09 | 0.49 | 709.14 | 01-MAY-08:62 | 0.57 |
June | 0.394745E+09 | 0.53 | 709.14 | 01-JUN-08:62 | 0.57 |
July | 0.496877E+09 | 0.55 | 709.14 | 01-JUL-08:61 | 0.57 |
August | 0.508858E+09 | 0.55 | 709.14 | 01-AUG-08:62 | 0.57 |
September | 0.286074E+09 | 0.50 | 709.14 | 01-SEP-08:61 | 0.57 |
October | 0.158807E+09 | 0.44 | 709.14 | 02-OCT-08:62 | 0.57 |
November | 0.176281E+09 | 0.43 | 709.14 | 04-NOV-08:62 | 0.57 |
December | 0.260982E+09 | 0.48 | 709.14 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.345609E+10 | 0.48 | |||
Minimum of Months | 0.158807E+09 | 0.42 | 709.14 | 0.57 | |
Maximum of Months | 0.508858E+09 | 0.55 | 709.14 | 0.58 |
Report: FanReportMonthly
For: ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 86591463.45 | 0.49 | 210.60 | 01-JAN-09:01 | 0.58 |
February | 74244692.24 | 0.47 | 210.60 | 01-FEB-09:01 | 0.58 |
March | 59365118.07 | 0.44 | 210.60 | 01-MAR-16:02 | 0.58 |
April | 58039820.95 | 0.46 | 210.60 | 01-APR-08:61 | 0.58 |
May | 72233235.92 | 0.48 | 210.60 | 01-MAY-15:02 | 0.58 |
June | 0.111925E+09 | 0.52 | 210.60 | 01-JUN-08:62 | 0.57 |
July | 0.136465E+09 | 0.54 | 210.60 | 01-JUL-08:61 | 0.57 |
August | 0.149834E+09 | 0.54 | 210.60 | 01-AUG-08:62 | 0.57 |
September | 87820754.04 | 0.50 | 210.60 | 01-SEP-08:61 | 0.57 |
October | 65341866.40 | 0.48 | 210.60 | 02-OCT-15:02 | 0.57 |
November | 55155960.45 | 0.44 | 210.60 | 01-NOV-08:62 | 0.57 |
December | 75953953.47 | 0.47 | 210.60 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.103297E+10 | 0.49 | |||
Minimum of Months | 55155960.45 | 0.44 | 210.60 | 0.57 | |
Maximum of Months | 0.149834E+09 | 0.54 | 210.60 | 0.58 |
Report: FanReportMonthly
For: ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 95310161.84 | 0.53 | 203.72 | 01-JAN-09:01 | 0.58 |
February | 84159461.38 | 0.51 | 203.72 | 01-FEB-09:01 | 0.58 |
March | 59018613.29 | 0.44 | 203.72 | 01-MAR-09:02 | 0.58 |
April | 50542761.92 | 0.44 | 203.72 | 01-APR-08:61 | 0.58 |
May | 65579738.22 | 0.47 | 203.72 | 01-MAY-15:02 | 0.58 |
June | 0.107115E+09 | 0.52 | 203.72 | 01-JUN-08:62 | 0.57 |
July | 0.130195E+09 | 0.54 | 203.72 | 01-JUL-08:61 | 0.57 |
August | 0.132358E+09 | 0.53 | 203.72 | 01-AUG-08:62 | 0.57 |
September | 68602678.05 | 0.48 | 203.72 | 01-SEP-08:61 | 0.57 |
October | 44426481.67 | 0.43 | 203.72 | 02-OCT-15:02 | 0.57 |
November | 60952680.77 | 0.46 | 203.72 | 01-NOV-08:62 | 0.57 |
December | 86036994.60 | 0.51 | 203.72 | 01-DEC-09:01 | 0.58 |
Annual Sum or Average | 0.984298E+09 | 0.49 | |||
Minimum of Months | 44426481.67 | 0.43 | 203.72 | 0.57 | |
Maximum of Months | 0.132358E+09 | 0.54 | 203.72 | 0.58 |
Report: FanReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.330040E+09 | 0.46 | 962.80 | 01-JAN-16:01 | 0.58 |
February | 0.286956E+09 | 0.48 | 962.80 | 01-FEB-16:01 | 0.58 |
March | 0.285134E+09 | 0.46 | 962.80 | 01-MAR-09:02 | 0.58 |
April | 0.280964E+09 | 0.47 | 962.80 | 01-APR-08:61 | 0.58 |
May | 0.324984E+09 | 0.48 | 962.80 | 01-MAY-15:02 | 0.58 |
June | 0.493220E+09 | 0.51 | 962.80 | 01-JUN-08:62 | 0.57 |
July | 0.650962E+09 | 0.53 | 962.80 | 01-JUL-08:61 | 0.57 |
August | 0.770307E+09 | 0.54 | 962.80 | 01-AUG-08:62 | 0.57 |
September | 0.574931E+09 | 0.51 | 962.80 | 01-SEP-08:61 | 0.57 |
October | 0.544651E+09 | 0.51 | 962.80 | 02-OCT-08:62 | 0.57 |
November | 0.264331E+09 | 0.45 | 962.80 | 01-NOV-15:02 | 0.58 |
December | 0.315442E+09 | 0.47 | 962.80 | 01-DEC-19:01 | 0.58 |
Annual Sum or Average | 0.512192E+10 | 0.49 | |||
Minimum of Months | 0.264331E+09 | 0.45 | 962.80 | 0.57 | |
Maximum of Months | 0.770307E+09 | 0.54 | 962.80 | 0.58 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.936310E+09 | 0.842679E+09 | 820.65 | 14-JAN-16:02 | 738.58 | 738.58 | 44.26 | 1.35 |
February | 0.787135E+09 | 0.708422E+09 | 801.55 | 06-FEB-07:05 | 721.39 | 721.39 | 46.84 | 1.29 |
March | 0.473750E+09 | 0.426375E+09 | 717.00 | 05-MAR-16:15 | 645.30 | 645.30 | 49.94 | 1.06 |
April | 0.257812E+09 | 0.232030E+09 | 681.34 | 01-APR-21:25 | 613.21 | 613.21 | 49.36 | 0.98 |
May | 53506128.73 | 48155515.86 | 568.57 | 02-MAY-03:25 | 511.72 | 511.72 | 43.57 | 0.75 |
June | 1733481.07 | 1560132.96 | 242.01 | 06-JUN-15:05 | 217.81 | 217.81 | 41.35 | 0.27 |
July | 504127.72 | 453714.95 | 185.33 | 24-JUL-08:06 | 166.80 | 166.80 | 56.35 | 0.20 |
August | 2050868.46 | 1845781.62 | 288.82 | 30-AUG-08:05 | 259.94 | 259.94 | 47.84 | 0.33 |
September | 10775930.63 | 9698337.56 | 322.97 | 26-SEP-15:05 | 290.68 | 290.68 | 59.64 | 0.37 |
October | 0.121849E+09 | 0.109664E+09 | 679.94 | 28-OCT-00:03 | 611.94 | 611.94 | 52.13 | 0.97 |
November | 0.473172E+09 | 0.425855E+09 | 734.07 | 26-NOV-04:20 | 660.66 | 660.66 | 67.65 | 1.09 |
December | 0.712511E+09 | 0.641260E+09 | 738.10 | 04-DEC-09:13 | 664.29 | 664.29 | 45.12 | 1.11 |
Annual Sum or Average | 0.383111E+10 | 0.344800E+10 | ||||||
Minimum of Months | 504127.72 | 453714.95 | 185.33 | 166.80 | 166.80 | 41.35 | 0.20 | |
Maximum of Months | 0.936310E+09 | 0.842679E+09 | 820.65 | 738.58 | 738.58 | 67.65 | 1.35 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP SECONDARY
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 845358.80 | 760822.92 | 42.08 | 18-JAN-16:04 | 37.87 | 37.87 | 8.40 | 3.27 |
February | 1769905.33 | 1592914.79 | 48.98 | 16-FEB-09:04 | 44.08 | 44.08 | 8.40 | 3.56 |
March | 11369454.77 | 10232509.29 | 316.70 | 27-MAR-18:02 | 285.03 | 285.03 | 7.91 | 9.30 |
April | 85519406.81 | 76967466.13 | 923.45 | 07-APR-15:03 | 831.10 | 831.10 | 6.90 | 15.15 |
May | 0.266262E+09 | 0.239636E+09 | 1389.58 | 31-MAY-18:03 | 1250.62 | 1250.62 | 7.50 | 18.09 |
June | 0.125899E+10 | 0.113309E+10 | 2696.41 | 24-JUN-18:03 | 2426.77 | 2426.77 | 7.33 | 23.89 |
July | 0.213595E+10 | 0.192235E+10 | 2356.96 | 26-JUL-18:03 | 2121.26 | 2121.26 | 7.41 | 22.60 |
August | 0.182439E+10 | 0.164195E+10 | 2325.64 | 03-AUG-18:05 | 2093.08 | 2093.08 | 6.74 | 22.48 |
September | 0.875036E+09 | 0.787532E+09 | 2188.33 | 07-SEP-20:00 | 1969.50 | 1969.50 | 7.15 | 21.91 |
October | 0.282811E+09 | 0.254530E+09 | 1155.96 | 05-OCT-18:02 | 1040.36 | 1040.36 | 7.74 | 16.71 |
November | 13713525.56 | 12342173.00 | 215.27 | 04-NOV-15:01 | 193.75 | 193.75 | 8.15 | 7.72 |
December | 3231056.06 | 2907950.45 | 61.20 | 17-DEC-16:04 | 55.08 | 55.08 | 8.40 | 4.03 |
Annual Sum or Average | 0.675988E+10 | 0.608389E+10 | ||||||
Minimum of Months | 845358.80 | 760822.92 | 42.08 | 37.87 | 37.87 | 6.74 | 3.27 | |
Maximum of Months | 0.213595E+10 | 0.192235E+10 | 2696.41 | 2426.77 | 2426.77 | 8.40 | 23.89 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.406856E+10 | 0.366170E+10 | 5127.50 | 01-JAN-09:03 | 4614.75 | 4614.75 | 8.43 | 35.94 |
February | 0.425046E+10 | 0.382541E+10 | 5127.50 | 01-FEB-00:03 | 4614.75 | 4614.75 | 8.40 | 35.94 |
March | 0.677161E+10 | 0.609445E+10 | 5127.50 | 01-MAR-00:03 | 4614.75 | 4614.75 | 8.40 | 35.94 |
April | 0.923893E+10 | 0.831504E+10 | 5127.50 | 01-APR-01:07 | 4614.75 | 4614.75 | 8.40 | 35.94 |
May | 0.132747E+11 | 0.119472E+11 | 5127.50 | 01-MAY-00:05 | 4614.75 | 4614.75 | 8.43 | 35.94 |
June | 0.132905E+11 | 0.119614E+11 | 5127.50 | 01-JUN-00:05 | 4614.75 | 4614.75 | 8.97 | 35.94 |
July | 0.137335E+11 | 0.123601E+11 | 5127.50 | 01-JUL-00:10 | 4614.75 | 4614.75 | 9.69 | 35.94 |
August | 0.137335E+11 | 0.123601E+11 | 5127.50 | 01-AUG-00:05 | 4614.75 | 4614.75 | 9.52 | 35.94 |
September | 0.132682E+11 | 0.119414E+11 | 5127.50 | 01-SEP-00:05 | 4614.75 | 4614.75 | 9.48 | 35.94 |
October | 0.127058E+11 | 0.114352E+11 | 5127.50 | 01-OCT-00:10 | 4614.75 | 4614.75 | 8.50 | 35.94 |
November | 0.707007E+10 | 0.636306E+10 | 5127.50 | 01-NOV-03:16 | 4614.75 | 4614.75 | 8.41 | 35.94 |
December | 0.576631E+10 | 0.518968E+10 | 5127.50 | 01-DEC-00:03 | 4614.75 | 4614.75 | 8.51 | 35.94 |
Annual Sum or Average | 0.117172E+12 | 0.105455E+12 | ||||||
Minimum of Months | 0.406856E+10 | 0.366170E+10 | 5127.50 | 4614.75 | 4614.75 | 8.40 | 35.94 | |
Maximum of Months | 0.137335E+11 | 0.123601E+11 | 5127.50 | 4614.75 | 4614.75 | 9.69 | 35.94 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.128314E+09 | 38494137.67 | 47.91 | 01-JAN-00:03 | 14.37 | 14.37 | 47.67 | 0.37 |
February | 0.115896E+09 | 34768898.54 | 47.91 | 01-FEB-00:03 | 14.37 | 14.37 | 48.42 | 0.37 |
March | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAR-00:03 | 14.37 | 14.37 | 48.52 | 0.37 |
April | 0.124175E+09 | 37252391.29 | 47.91 | 01-APR-00:10 | 14.37 | 14.37 | 51.85 | 0.37 |
May | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAY-00:05 | 14.37 | 14.37 | 51.69 | 0.37 |
June | 0.124175E+09 | 37252391.29 | 47.91 | 01-JUN-00:05 | 14.37 | 14.37 | 52.74 | 0.37 |
July | 0.128314E+09 | 38494137.67 | 47.91 | 01-JUL-00:10 | 14.37 | 14.37 | 52.90 | 0.37 |
August | 0.128314E+09 | 38494137.67 | 47.91 | 01-AUG-00:05 | 14.37 | 14.37 | 52.93 | 0.37 |
September | 0.124175E+09 | 37252391.29 | 47.91 | 01-SEP-00:05 | 14.37 | 14.37 | 52.51 | 0.37 |
October | 0.128314E+09 | 38494137.67 | 47.91 | 01-OCT-00:10 | 14.37 | 14.37 | 52.49 | 0.37 |
November | 0.124175E+09 | 37252391.29 | 47.91 | 01-NOV-00:05 | 14.37 | 14.37 | 52.34 | 0.37 |
December | 0.128314E+09 | 38494137.67 | 47.91 | 01-DEC-00:03 | 14.37 | 14.37 | 49.39 | 0.37 |
Annual Sum or Average | 0.151079E+10 | 0.453237E+09 | ||||||
Minimum of Months | 0.115896E+09 | 34768898.54 | 47.91 | 14.37 | 14.37 | 47.67 | 0.37 | |
Maximum of Months | 0.128314E+09 | 38494137.67 | 47.91 | 14.37 | 14.37 | 52.93 | 0.37 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 47.42 | 82.20 | 53377.77 | 244134.17 | 02-JAN-09:03 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 53.23 | 81.26 | 50165.40 | 250248.53 | 06-FEB-09:01 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 59.62 | 80.15 | 21699.48 | 188916.36 | 31-MAR-15:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 62.50 | 80.20 | 13755.62 | 179631.66 | 21-APR-15:01 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 39.58 | 79.40 | 3163.56 | 121348.43 | 15-MAY-02:45 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 41.58 | 41.58 | 100.39 | 42838.50 | 06-JUN-15:05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 49.90 | 49.90 | 21.57 | 22033.06 | 14-JUL-08:07 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 58.79 | 58.79 | 111.42 | 43179.12 | 30-AUG-08:05 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 57.19 | 57.19 | 650.26 | 58380.05 | 24-SEP-05:16 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 32.72 | 79.40 | 6170.83 | 141585.99 | 26-OCT-23:27 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 47.48 | 79.40 | 23888.13 | 203416.42 | 27-NOV-16:01 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 48.34 | 80.08 | 32800.61 | 192608.75 | 04-DEC-19:01 |
Annual Sum or Average | 0.00 | 16970.32 | ||||||
Minimum of Months | 0.00 | 0.00 | 32.72 | 41.58 | 21.57 | 22033.06 | ||
Maximum of Months | 0.00 | 0.00 | 62.50 | 82.20 | 53377.77 | 250248.53 |
Report: CondLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 1928.75 | 48858.99 | 13-JAN-09:04 | 8.69 | 8.37 | 0.00 | 0.00 | 01-JAN-00:03 |
February | 2686.08 | 52898.63 | 16-FEB-09:04 | 8.72 | 8.37 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 7209.57 | 242235.07 | 27-MAR-15:02 | 9.34 | 7.73 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 29509.56 | 384848.35 | 07-APR-15:03 | 9.42 | 6.87 | 0.00 | 0.00 | 01-APR-00:10 |
May | 84419.21 | 519182.81 | 31-MAY-18:03 | 10.93 | 7.48 | 0.00 | 0.00 | 01-MAY-00:05 |
June | 289886.33 | 753327.34 | 24-JUN-18:03 | 12.31 | 7.30 | 0.00 | 0.00 | 01-JUN-00:05 |
July | 422855.05 | 716524.30 | 14-JUL-18:03 | 12.06 | 7.30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 359016.28 | 698936.02 | 04-AUG-18:03 | 11.34 | 6.70 | 0.00 | 0.00 | 01-AUG-00:05 |
September | 210820.64 | 659088.70 | 22-SEP-18:02 | 11.81 | 7.43 | 0.00 | 0.00 | 01-SEP-00:05 |
October | 86716.27 | 493398.93 | 05-OCT-15:03 | 10.67 | 7.39 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 8398.10 | 138801.50 | 04-NOV-15:01 | 9.04 | 8.11 | 0.00 | 0.00 | 01-NOV-00:05 |
December | 3627.31 | 58343.85 | 17-DEC-16:04 | 8.76 | 8.37 | 0.00 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 126500.26 | 0.00 | ||||||
Minimum of Months | 1928.75 | 48858.99 | 8.69 | 6.70 | 0.00 | 0.00 | ||
Maximum of Months | 422855.05 | 753327.34 | 12.31 | 8.37 | 0.00 | 0.00 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 47.67 | 59.79 | 28260.05 | 61840.28 | 24-JAN-07:20 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 48.42 | 58.72 | 28541.20 | 64221.49 | 16-FEB-18:41 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 48.52 | 58.94 | 27934.38 | 65211.05 | 26-MAR-07:41 |
April | 0.00 | 0.00 | 01-APR-00:10 | 51.85 | 59.26 | 26541.77 | 64141.31 | 13-APR-06:21 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 51.69 | 58.49 | 24818.45 | 56873.09 | 02-MAY-06:05 |
June | 0.00 | 0.00 | 01-JUN-00:05 | 52.74 | 59.75 | 23174.66 | 48133.40 | 01-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 52.90 | 58.67 | 22020.11 | 44991.42 | 03-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:05 | 52.93 | 58.61 | 21739.19 | 45215.16 | 22-AUG-06:50 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 52.51 | 58.16 | 22357.33 | 49893.27 | 20-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 52.49 | 59.55 | 23700.37 | 56813.64 | 27-OCT-20:11 |
November | 0.00 | 0.00 | 01-NOV-00:05 | 52.34 | 58.91 | 25447.27 | 59097.62 | 27-NOV-07:19 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 49.39 | 59.22 | 27134.22 | 64015.78 | 26-DEC-21:31 |
Annual Sum or Average | 0.00 | 25119.44 | ||||||
Minimum of Months | 0.00 | 0.00 | 47.67 | 58.16 | 21739.19 | 44991.42 | ||
Maximum of Months | 0.00 | 0.00 | 52.93 | 59.79 | 28541.20 | 65211.05 |
Report: ZoneTemperatureOscillationReportMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.679245E+11 | 0.00 | 0.227956E+09 | 0.330328E+11 | 0.00 | 0.00 |
February | 0.590772E+11 | 0.00 | 0.207446E+09 | 0.295480E+11 | 0.00 | 0.00 |
March | 0.321814E+11 | 0.00 | 0.355282E+10 | 0.348413E+11 | 0.00 | 0.00 |
April | 0.270362E+11 | 0.00 | 0.341923E+11 | 0.345567E+11 | 0.00 | 0.00 |
May | 0.780898E+10 | 0.00 | 0.126129E+12 | 0.370209E+11 | 0.00 | 0.00 |
June | 0.205975E+09 | 0.00 | 0.519220E+12 | 0.380460E+11 | 0.00 | 0.00 |
July | 17396389.89 | 0.00 | 0.817177E+12 | 0.409099E+11 | 0.00 | 0.00 |
August | 0.257035E+09 | 0.00 | 0.666890E+12 | 0.422116E+11 | 0.00 | 0.00 |
September | 0.156042E+10 | 0.00 | 0.362678E+12 | 0.382746E+11 | 0.00 | 0.00 |
October | 0.139503E+11 | 0.00 | 0.125687E+12 | 0.384278E+11 | 0.00 | 0.00 |
November | 0.362765E+11 | 0.00 | 0.359820E+10 | 0.351837E+11 | 0.00 | 0.00 |
December | 0.344603E+11 | 0.00 | 0.459344E+09 | 0.340181E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.280756E+12 | 0.00 | 0.266002E+13 | 0.436071E+12 | 0.00 | 0.00 |
Minimum of Months | 17396389.89 | 0.00 | 0.207446E+09 | 0.295480E+11 | 0.00 | 0.00 |
Maximum of Months | 0.679245E+11 | 0.00 | 0.817177E+12 | 0.422116E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.472799E+10 | 0.00 | 0.00 | 0.587890E+10 | 0.00 | 0.00 |
February | 0.483628E+10 | 0.00 | 0.00 | 0.530997E+10 | 0.00 | 0.00 |
March | 0.539191E+09 | 0.00 | 0.697382E+09 | 0.587890E+10 | 0.00 | 0.00 |
April | 3170.73 | 0.00 | 0.634269E+10 | 0.568926E+10 | 0.00 | 0.00 |
May | 17171.13 | 0.00 | 0.232123E+11 | 0.587890E+10 | 0.00 | 0.00 |
June | 21241.03 | 0.00 | 0.961906E+11 | 0.568926E+10 | 0.00 | 0.00 |
July | 12464.12 | 0.00 | 0.130865E+12 | 0.587890E+10 | 0.00 | 0.00 |
August | 21984.90 | 0.00 | 0.107294E+12 | 0.587890E+10 | 0.00 | 0.00 |
September | 16076.36 | 0.00 | 0.663363E+11 | 0.568926E+10 | 0.00 | 0.00 |
October | 23495.34 | 0.00 | 0.245200E+11 | 0.587890E+10 | 0.00 | 0.00 |
November | 0.434607E+09 | 0.00 | 0.605095E+09 | 0.568926E+10 | 0.00 | 0.00 |
December | 0.903161E+09 | 0.00 | 2300.65 | 0.587890E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.114414E+11 | 0.00 | 0.456064E+12 | 0.692193E+11 | 0.00 | 0.00 |
Minimum of Months | 3170.73 | 0.00 | 0.00 | 0.530997E+10 | 0.00 | 0.00 |
Maximum of Months | 0.483628E+10 | 0.00 | 0.130865E+12 | 0.587890E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.330328E+11 | 0.227956E+09 | 0.679245E+11 | 0.544395E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.295480E+11 | 0.207447E+09 | 0.590772E+11 | 0.544316E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.348413E+11 | 0.355316E+10 | 0.321814E+11 | 0.372526E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.345567E+11 | 0.341924E+11 | 0.270362E+11 | 0.150063E+12 | 0.148108E+09 | 0.00 | 0.00 | 0.00 |
May | 0.370209E+11 | 0.126129E+12 | 0.780898E+10 | 0.232786E+11 | 0.274233E+10 | 0.00 | 0.00 | 0.00 |
June | 0.380460E+11 | 0.519220E+12 | 0.205975E+09 | 0.121927E+09 | 0.474842E+11 | 0.00 | 0.00 | 0.00 |
July | 0.409099E+11 | 0.817177E+12 | 17396389.89 | 0.00 | 0.185054E+12 | 0.00 | 0.00 | 0.00 |
August | 0.422116E+11 | 0.666890E+12 | 0.257035E+09 | 0.00 | 0.149522E+12 | 0.00 | 0.00 | 0.00 |
September | 0.382746E+11 | 0.362678E+12 | 0.156042E+10 | 0.339044E+10 | 0.190039E+11 | 0.00 | 0.00 | 0.00 |
October | 0.384278E+11 | 0.125688E+12 | 0.139503E+11 | 0.701619E+11 | 0.498861E+09 | 0.00 | 0.00 | 0.00 |
November | 0.351837E+11 | 0.359820E+10 | 0.362765E+11 | 0.271267E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.340181E+11 | 0.459345E+09 | 0.344603E+11 | 0.480351E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.436071E+12 | 0.266002E+13 | 0.280756E+12 | 0.245987E+13 | 0.404454E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.295480E+11 | 0.207447E+09 | 17396389.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.422116E+11 | 0.817177E+12 | 0.679245E+11 | 0.544395E+12 | 0.185054E+12 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.587890E+10 | 0.00 | 0.472799E+10 | 0.978969E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530997E+10 | 0.00 | 0.483628E+10 | 0.960321E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.587890E+10 | 0.697382E+09 | 0.539191E+09 | 0.702677E+11 | 194869.44 | 0.00 | 0.00 | 0.00 |
April | 0.568926E+10 | 0.634269E+10 | 3170.73 | 0.341716E+11 | 0.161524E+09 | 0.00 | 0.00 | 0.00 |
May | 0.587890E+10 | 0.232123E+11 | 17171.13 | 0.728761E+10 | 0.136179E+10 | 0.00 | 0.00 | 0.00 |
June | 0.568926E+10 | 0.961906E+11 | 21241.03 | 0.128936E+09 | 0.192307E+11 | 0.00 | 0.00 | 0.00 |
July | 0.587890E+10 | 0.130865E+12 | 12464.12 | 29061.28 | 0.666868E+11 | 0.00 | 0.00 | 0.00 |
August | 0.587890E+10 | 0.107294E+12 | 21984.90 | 88902343.20 | 0.511435E+11 | 0.00 | 0.00 | 0.00 |
September | 0.568926E+10 | 0.663363E+11 | 16076.36 | 0.146367E+10 | 0.118721E+11 | 0.00 | 0.00 | 0.00 |
October | 0.587890E+10 | 0.245200E+11 | 23495.34 | 0.178925E+11 | 0.663179E+09 | 0.00 | 0.00 | 0.00 |
November | 0.568926E+10 | 0.605095E+09 | 0.434607E+09 | 0.560636E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587890E+10 | 2300.65 | 0.903161E+09 | 0.869951E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692193E+11 | 0.456064E+12 | 0.114414E+11 | 0.468289E+12 | 0.151120E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.530997E+10 | 0.00 | 3170.73 | 29061.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587890E+10 | 0.130865E+12 | 0.483628E+10 | 0.978969E+11 | 0.666868E+11 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.330328E+11 | 0.679245E+11 | 0.227956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.295480E+11 | 0.590772E+11 | 0.207446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.348413E+11 | 0.321814E+11 | 0.355282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.345567E+11 | 0.270362E+11 | 0.341923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.370209E+11 | 0.780898E+10 | 0.126129E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.380460E+11 | 0.205975E+09 | 0.519220E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.409099E+11 | 17396389.89 | 0.817177E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.422116E+11 | 0.257035E+09 | 0.666890E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.382746E+11 | 0.156042E+10 | 0.362678E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.384278E+11 | 0.139503E+11 | 0.125687E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.351837E+11 | 0.362765E+11 | 0.359820E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.340181E+11 | 0.344603E+11 | 0.459344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.436071E+12 | 0.280756E+12 | 0.266002E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.295480E+11 | 17396389.89 | 0.207446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.422116E+11 | 0.679245E+11 | 0.817177E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.587890E+10 | 0.472799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530997E+10 | 0.483628E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.587890E+10 | 0.539191E+09 | 0.697382E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.568926E+10 | 3170.73 | 0.634269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.587890E+10 | 17171.13 | 0.232123E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.568926E+10 | 21241.03 | 0.961906E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587890E+10 | 12464.12 | 0.130865E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.587890E+10 | 21984.90 | 0.107294E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.568926E+10 | 16076.36 | 0.663363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.587890E+10 | 23495.34 | 0.245200E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.568926E+10 | 0.434607E+09 | 0.605095E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587890E+10 | 0.903161E+09 | 2300.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692193E+11 | 0.114414E+11 | 0.456064E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.530997E+10 | 3170.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587890E+10 | 0.483628E+10 | 0.130865E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.272467E+11 | 0.00 | 0.00 | 23605185.09 | 0.00 | 0.00 | 0.234291E+11 | 0.00 | 0.95 |
February | 0.365968E+11 | 0.00 | 0.00 | 5204941.31 | 0.00 | 0.00 | 0.853327E+10 | 0.00 | 0.94 |
March | 0.448183E+11 | 0.00 | 0.00 | 963795.66 | 0.00 | 0.00 | 0.362255E+10 | 0.00 | 0.92 |
April | 0.449798E+11 | 0.00 | 0.00 | 71020.12 | 6613760.25 | 0.00 | 0.283304E+09 | 0.00 | 0.93 |
May | 0.381455E+11 | 0.00 | 0.00 | 0.00 | 0.222987E+09 | 0.00 | 0.00 | 0.00 | 0.97 |
June | 0.100617E+11 | 0.538656E+09 | 0.00 | 211055.08 | 0.965981E+10 | 0.00 | 0.397116E+09 | 0.00 | 0.94 |
July | 0.506465E+09 | 0.571257E+10 | 0.00 | 254259.05 | 0.193036E+11 | 0.00 | 57854585.23 | 0.00 | 0.87 |
August | 0.597703E+09 | 0.739538E+10 | 0.00 | 11362311.29 | 0.801538E+10 | 0.00 | 0.583468E+10 | 0.00 | 0.92 |
September | 0.775494E+09 | 0.522334E+10 | 0.00 | 41327837.50 | 0.537961E+09 | 0.00 | 0.221503E+11 | 0.00 | 1.03 |
October | 0.106908E+10 | 0.348071E+09 | 0.00 | 93202830.70 | 45104347.27 | 0.00 | 0.453420E+11 | 0.00 | 1.08 |
November | 0.239845E+10 | 0.00 | 0.00 | 0.117107E+09 | 0.00 | 0.00 | 0.534184E+11 | 0.00 | 1.05 |
December | 0.630897E+10 | 0.00 | 0.00 | 69174528.50 | 0.00 | 0.00 | 0.451143E+11 | 0.00 | 0.99 |
Annual Sum or Average | 0.213505E+12 | 0.192180E+11 | 0.00 | 0.362484E+09 | 0.377915E+11 | 0.00 | 0.208183E+12 | 0.00 | 0.97 |
Minimum of Months | 0.506465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Maximum of Months | 0.449798E+11 | 0.739538E+10 | 0.00 | 0.117107E+09 | 0.193036E+11 | 0.00 | 0.534184E+11 | 0.00 | 1.08 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.392604E+10 | 0.00 | 0.00 | 294831.65 | 0.00 | 0.351814E+10 | 0.232851E+09 | 0.00 | 2.59 |
February | 0.399247E+10 | 0.00 | 0.00 | 578147.27 | 0.00 | 0.262362E+10 | 0.351950E+09 | 0.00 | 2.61 |
March | 0.618508E+10 | 0.00 | 0.00 | 1024933.51 | 0.00 | 0.757753E+09 | 0.596149E+09 | 0.00 | 2.58 |
April | 0.642173E+10 | 1386996.09 | 0.00 | 675211.50 | 103116.72 | 0.168228E+09 | 0.404177E+09 | 0.00 | 2.63 |
May | 0.559473E+10 | 29213215.20 | 0.00 | 375409.22 | 6965484.55 | 460122.84 | 0.291848E+09 | 0.00 | 2.72 |
June | 0.148124E+10 | 0.746787E+09 | 0.00 | 361467.48 | 0.840452E+09 | 0.00 | 0.132734E+09 | 0.00 | 2.64 |
July | 65925377.50 | 0.234326E+10 | 0.00 | 68961.09 | 0.162469E+10 | 0.00 | 21142418.17 | 0.00 | 2.49 |
August | 0.736467E+09 | 0.213710E+10 | 0.00 | 1198390.29 | 0.439755E+09 | 0.00 | 0.244086E+09 | 0.00 | 2.75 |
September | 0.260465E+10 | 0.436509E+09 | 0.00 | 2365249.01 | 0.453255E+09 | 0.00 | 0.742888E+09 | 0.00 | 2.84 |
October | 0.488618E+10 | 84268075.38 | 0.00 | 3450609.08 | 1331782.40 | 491965.92 | 0.154207E+10 | 0.00 | 2.85 |
November | 0.634586E+10 | 0.00 | 0.00 | 826808.72 | 0.00 | 0.639685E+09 | 0.470601E+09 | 0.00 | 2.57 |
December | 0.471651E+10 | 0.00 | 0.00 | 1011116.57 | 0.00 | 0.228040E+10 | 0.403131E+09 | 0.00 | 2.60 |
Annual Sum or Average | 0.469569E+11 | 0.577852E+10 | 0.00 | 12231135.39 | 0.336655E+10 | 0.998878E+10 | 0.543362E+10 | 0.00 | 2.65 |
Minimum of Months | 65925377.50 | 0.00 | 0.00 | 68961.09 | 0.00 | 0.00 | 21142418.17 | 0.00 | 2.49 |
Maximum of Months | 0.642173E+10 | 0.234326E+10 | 0.00 | 3450609.08 | 0.162469E+10 | 0.351814E+10 | 0.154207E+10 | 0.00 | 2.85 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.474020E+10 | 0.00 | 0.00 | 573.78 | 0.00 | 0.00 | 2466653.99 | 0.00 | 1.38 |
February | 0.430346E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.39 |
March | 0.449475E+10 | 0.00 | 0.00 | 39847.18 | 0.00 | 0.00 | 0.129256E+09 | 0.00 | 1.37 |
April | 0.392820E+10 | 0.00 | 0.00 | 316025.60 | 631427.21 | 0.00 | 0.397012E+09 | 0.00 | 1.40 |
May | 0.277763E+10 | 6719782.98 | 0.00 | 738767.67 | 14599608.88 | 0.00 | 0.874571E+09 | 0.00 | 1.46 |
June | 0.338744E+09 | 0.574681E+09 | 0.00 | 1060247.65 | 0.429228E+09 | 0.00 | 0.679249E+09 | 0.00 | 1.45 |
July | 2210246.15 | 0.198111E+10 | 0.00 | 294249.06 | 0.525270E+09 | 0.00 | 54278243.12 | 0.00 | 1.36 |
August | 48892798.69 | 0.139917E+10 | 0.00 | 1601854.44 | 0.169343E+09 | 0.00 | 0.585385E+09 | 0.00 | 1.46 |
September | 0.103223E+10 | 0.365213E+09 | 0.00 | 1377960.41 | 0.172391E+09 | 0.00 | 0.103038E+10 | 0.00 | 1.48 |
October | 0.271668E+10 | 15221369.58 | 0.00 | 1120798.09 | 21996200.78 | 0.00 | 0.115523E+10 | 0.00 | 1.44 |
November | 0.439023E+10 | 0.00 | 0.00 | 76267.41 | 0.00 | 0.00 | 0.193333E+09 | 0.00 | 1.37 |
December | 0.454434E+10 | 0.00 | 0.00 | 63.81 | 0.00 | 0.00 | 933283.78 | 0.00 | 1.38 |
Annual Sum or Average | 0.333176E+11 | 0.434212E+10 | 0.00 | 6626655.11 | 0.133346E+10 | 0.00 | 0.510210E+10 | 0.00 | 1.41 |
Minimum of Months | 2210246.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.36 |
Maximum of Months | 0.474020E+10 | 0.198111E+10 | 0.00 | 1601854.44 | 0.525270E+09 | 0.00 | 0.115523E+10 | 0.00 | 1.48 |
Report: MechanicalVentilationLoadsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.345636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115213E+10 | 0.00 | 0.00 | 0.63 |
February | 0.303162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115009E+10 | 0.00 | 0.00 | 0.64 |
March | 0.447392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19313989.85 | 0.00 | 0.00 | 0.63 |
April | 0.419910E+10 | 0.00 | 0.00 | 0.00 | 613563.61 | 0.00 | 0.00 | 0.00 | 0.64 |
May | 0.351898E+10 | 136399.75 | 0.00 | 41320.11 | 20550255.57 | 0.00 | 19778263.61 | 0.00 | 0.67 |
June | 0.877859E+09 | 0.211635E+09 | 0.00 | 184825.69 | 0.743616E+09 | 0.00 | 94750933.09 | 0.00 | 0.65 |
July | 16562423.34 | 0.112271E+10 | 0.00 | 140044.08 | 0.126402E+10 | 0.00 | 36782783.79 | 0.00 | 0.61 |
August | 0.401752E+09 | 0.948735E+09 | 0.00 | 525952.79 | 0.525840E+09 | 0.00 | 0.193884E+09 | 0.00 | 0.64 |
September | 0.185742E+10 | 94567603.67 | 0.00 | 207998.45 | 0.408548E+09 | 0.00 | 0.115297E+09 | 0.00 | 0.66 |
October | 0.373856E+10 | 0.00 | 0.00 | 546.52 | 36024047.46 | 0.00 | 718565.48 | 0.00 | 0.65 |
November | 0.441978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34177251.62 | 0.00 | 0.00 | 0.63 |
December | 0.437717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39514282.30 | 0.00 | 0.00 | 0.63 |
Annual Sum or Average | 0.343691E+11 | 0.237779E+10 | 0.00 | 1100687.64 | 0.299921E+10 | 0.239523E+10 | 0.461211E+09 | 0.00 | 0.64 |
Minimum of Months | 16562423.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.61 |
Maximum of Months | 0.447392E+10 | 0.112271E+10 | 0.00 | 525952.79 | 0.126402E+10 | 0.115213E+10 | 0.193884E+09 | 0.00 | 0.67 |
Report: MechanicalVentilationLoadsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.104372E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118972E+10 | 0.00 | 0.00 | 0.53 |
February | 0.915339E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111127E+10 | 0.00 | 0.00 | 0.54 |
March | 0.201928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158304E+09 | 0.00 | 0.00 | 0.53 |
April | 0.203474E+10 | 0.00 | 0.00 | 0.00 | 297355.31 | 299013.06 | 0.00 | 0.00 | 0.54 |
May | 0.171503E+10 | 0.00 | 0.00 | 0.00 | 10025507.75 | 0.00 | 0.00 | 0.00 | 0.56 |
June | 0.464837E+09 | 21644016.50 | 0.00 | 15108.67 | 0.436895E+09 | 0.00 | 5385973.95 | 0.00 | 0.54 |
July | 12425604.39 | 0.247227E+09 | 0.00 | 26669.93 | 0.878719E+09 | 0.00 | 12977408.09 | 0.00 | 0.50 |
August | 0.254692E+09 | 0.310426E+09 | 0.00 | 75057.67 | 0.377770E+09 | 0.00 | 30752494.46 | 0.00 | 0.53 |
September | 0.951506E+09 | 11052318.72 | 0.00 | 10008.77 | 0.230649E+09 | 0.00 | 3978399.68 | 0.00 | 0.55 |
October | 0.181219E+10 | 0.00 | 0.00 | 0.00 | 17458567.43 | 0.00 | 0.00 | 0.00 | 0.55 |
November | 0.199548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163069E+09 | 0.00 | 0.00 | 0.53 |
December | 0.171350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.426980E+09 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.149327E+11 | 0.590349E+09 | 0.00 | 126845.04 | 0.195182E+10 | 0.304964E+10 | 53094276.19 | 0.00 | 0.54 |
Minimum of Months | 12425604.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 |
Maximum of Months | 0.203474E+10 | 0.310426E+09 | 0.00 | 75057.67 | 0.878719E+09 | 0.118972E+10 | 30752494.46 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.115600E+10 | 0.00 | 0.00 | 0.119290E+09 | 0.00 | 0.00 | 0.726910E+11 | 0.00 | 21.21 |
February | 0.120959E+10 | 0.00 | 0.00 | 91764306.21 | 0.00 | 0.00 | 0.656639E+11 | 0.00 | 21.37 |
March | 0.167828E+10 | 0.00 | 0.00 | 0.154112E+09 | 0.00 | 0.00 | 0.718261E+11 | 0.00 | 21.30 |
April | 0.108956E+10 | 8576114.01 | 0.00 | 0.138253E+09 | 0.00 | 0.00 | 0.675802E+11 | 0.00 | 21.78 |
May | 0.851072E+09 | 0.304972E+09 | 0.00 | 99119174.19 | 343656.18 | 0.00 | 0.567001E+11 | 0.00 | 22.74 |
June | 5393020.11 | 0.151364E+11 | 0.00 | 43329880.83 | 16747778.16 | 0.00 | 0.155057E+11 | 0.00 | 21.75 |
July | 0.00 | 0.371132E+11 | 0.00 | 4557698.84 | 40289976.60 | 0.00 | 0.779939E+09 | 0.00 | 19.90 |
August | 4762834.86 | 0.226247E+11 | 0.00 | 32620049.40 | 19843787.24 | 0.00 | 0.901375E+10 | 0.00 | 20.93 |
September | 0.191727E+09 | 0.818185E+10 | 0.00 | 65539752.56 | 1286741.46 | 0.00 | 0.313314E+11 | 0.00 | 22.25 |
October | 0.701624E+09 | 0.521931E+09 | 0.00 | 0.114172E+09 | 0.00 | 0.00 | 0.596886E+11 | 0.00 | 22.25 |
November | 0.164204E+10 | 0.00 | 0.00 | 0.144259E+09 | 0.00 | 0.00 | 0.708950E+11 | 0.00 | 21.21 |
December | 0.118629E+10 | 0.00 | 0.00 | 0.122988E+09 | 0.00 | 0.00 | 0.700516E+11 | 0.00 | 21.23 |
Annual Sum or Average | 0.971634E+10 | 0.838916E+11 | 0.00 | 0.113001E+10 | 78511939.65 | 0.00 | 0.591727E+12 | 0.00 | 21.49 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 4557698.84 | 0.00 | 0.00 | 0.779939E+09 | 0.00 | 19.90 |
Maximum of Months | 0.167828E+10 | 0.371132E+11 | 0.00 | 0.154112E+09 | 40289976.60 | 0.00 | 0.726910E+11 | 0.00 | 22.74 |
Report: MechanicalVentilationLoadsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.269682E+11 | 0.00 | 0.00 | 3257268.03 | 0.00 | 0.241219E+09 | 0.380885E+10 | 0.00 | 3.73 |
February | 0.224308E+11 | 0.00 | 0.00 | 5871287.47 | 0.00 | 0.00 | 0.579097E+10 | 0.00 | 3.77 |
March | 0.191274E+11 | 0.00 | 0.00 | 11825809.62 | 0.00 | 0.00 | 0.114617E+11 | 0.00 | 3.73 |
April | 0.152387E+11 | 5623634.43 | 0.00 | 12114635.55 | 0.00 | 0.00 | 0.130612E+11 | 0.00 | 3.79 |
May | 0.757063E+10 | 0.126571E+09 | 0.00 | 15152377.88 | 14653697.46 | 0.00 | 0.162311E+11 | 0.00 | 3.93 |
June | 0.618039E+09 | 0.540971E+10 | 0.00 | 12071421.99 | 0.105063E+10 | 0.00 | 0.594238E+10 | 0.00 | 3.84 |
July | 13585678.84 | 0.151648E+11 | 0.00 | 1932230.40 | 0.105222E+10 | 0.00 | 0.358611E+09 | 0.00 | 3.64 |
August | 0.146753E+09 | 0.100502E+11 | 0.00 | 13784050.55 | 0.349212E+09 | 0.00 | 0.398271E+10 | 0.00 | 4.00 |
September | 0.226921E+10 | 0.300663E+10 | 0.00 | 23009739.84 | 0.610812E+09 | 0.00 | 0.113564E+11 | 0.00 | 4.11 |
October | 0.511354E+10 | 0.322025E+09 | 0.00 | 33914301.59 | 479265.04 | 0.00 | 0.211107E+11 | 0.00 | 4.12 |
November | 0.191585E+11 | 0.00 | 0.00 | 10310401.34 | 0.00 | 0.00 | 0.110443E+11 | 0.00 | 3.71 |
December | 0.235217E+11 | 0.00 | 0.00 | 7517697.39 | 0.00 | 0.00 | 0.648401E+10 | 0.00 | 3.76 |
Annual Sum or Average | 0.142177E+12 | 0.340855E+11 | 0.00 | 0.150761E+09 | 0.307801E+10 | 0.241219E+09 | 0.110633E+12 | 0.00 | 3.84 |
Minimum of Months | 13585678.84 | 0.00 | 0.00 | 1932230.40 | 0.00 | 0.00 | 0.358611E+09 | 0.00 | 3.64 |
Maximum of Months | 0.269682E+11 | 0.151648E+11 | 0.00 | 33914301.59 | 0.105222E+10 | 0.241219E+09 | 0.211107E+11 | 0.00 | 4.12 |
Report: MechanicalVentilationLoadsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.894717E+11 | 0.00 | 0.00 | 2017237.06 | 0.00 | 0.00 | 0.458667E+10 | 0.00 | 1.63 |
February | 0.802304E+11 | 0.00 | 0.00 | 1308935.25 | 0.00 | 0.00 | 0.502619E+10 | 0.00 | 1.64 |
March | 0.695864E+11 | 0.00 | 0.00 | 18653611.29 | 0.00 | 0.00 | 0.224116E+11 | 0.00 | 1.62 |
April | 0.526019E+11 | 10276312.77 | 0.00 | 34916625.18 | 2233200.68 | 0.00 | 0.338867E+11 | 0.00 | 1.67 |
May | 0.256964E+11 | 0.304705E+09 | 0.00 | 57392837.73 | 0.117679E+09 | 0.00 | 0.480092E+11 | 0.00 | 1.75 |
June | 0.218263E+10 | 0.158603E+11 | 0.00 | 44254951.01 | 0.459828E+10 | 0.00 | 0.189433E+11 | 0.00 | 1.77 |
July | 24338842.72 | 0.470678E+11 | 0.00 | 7402704.86 | 0.473583E+10 | 0.00 | 0.122078E+10 | 0.00 | 1.69 |
August | 0.322954E+09 | 0.299076E+11 | 0.00 | 45057352.13 | 0.209433E+10 | 0.00 | 0.134286E+11 | 0.00 | 1.80 |
September | 0.667063E+10 | 0.902956E+10 | 0.00 | 66914586.59 | 0.210312E+10 | 0.00 | 0.358700E+11 | 0.00 | 1.81 |
October | 0.189130E+11 | 0.692674E+09 | 0.00 | 85662698.09 | 49401303.62 | 0.00 | 0.604086E+11 | 0.00 | 1.75 |
November | 0.653485E+11 | 0.00 | 0.00 | 23081659.98 | 0.00 | 0.00 | 0.260130E+11 | 0.00 | 1.62 |
December | 0.800521E+11 | 0.00 | 0.00 | 4084176.18 | 0.00 | 0.00 | 0.100488E+11 | 0.00 | 1.63 |
Annual Sum or Average | 0.491101E+12 | 0.102873E+12 | 0.00 | 0.390747E+09 | 0.137009E+11 | 0.00 | 0.279854E+12 | 0.00 | 1.70 |
Minimum of Months | 24338842.72 | 0.00 | 0.00 | 1308935.25 | 0.00 | 0.00 | 0.122078E+10 | 0.00 | 1.62 |
Maximum of Months | 0.894717E+11 | 0.470678E+11 | 0.00 | 85662698.09 | 0.473583E+10 | 0.00 | 0.604086E+11 | 0.00 | 1.81 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.312751E+09 | 0.00 | 0.00 | 494859.25 | 0.00 | 0.123599E+10 | 36379754.71 | 0.00 | 0.47 |
February | 0.323696E+09 | 0.00 | 0.00 | 921087.18 | 0.00 | 0.111584E+10 | 71022571.08 | 0.00 | 0.47 |
March | 0.380143E+09 | 81138.54 | 0.00 | 4593474.53 | 0.00 | 0.876607E+09 | 0.369223E+09 | 0.00 | 0.47 |
April | 0.309256E+09 | 2290010.05 | 0.00 | 7139893.12 | 979987.09 | 0.498533E+09 | 0.684319E+09 | 0.00 | 0.47 |
May | 0.183716E+09 | 28669821.00 | 29656.78 | 11132480.46 | 5342035.20 | 65244727.26 | 0.974720E+09 | 4534.08 | 0.47 |
June | 12788305.10 | 0.721180E+09 | 383614.11 | 4470392.53 | 48215107.66 | 155643.47 | 0.195364E+09 | 15600.29 | 0.48 |
July | 26656.78 | 0.140507E+10 | 1226636.56 | 112562.81 | 64206094.42 | 146.74 | 1813823.34 | 21993.82 | 0.47 |
August | 4704232.42 | 0.985526E+09 | 675396.98 | 2717512.73 | 38754490.67 | 80212.04 | 75386967.02 | 19384.58 | 0.47 |
September | 68493438.05 | 0.361708E+09 | 488555.28 | 6899151.15 | 43498215.38 | 6402270.81 | 0.472478E+09 | 12507.63 | 0.47 |
October | 0.192397E+09 | 71204881.38 | 44939.22 | 9113954.64 | 5410952.21 | 0.147051E+09 | 0.924096E+09 | 1020.89 | 0.47 |
November | 0.408108E+09 | 0.00 | 0.00 | 1634923.24 | 0.00 | 0.881372E+09 | 0.312719E+09 | 0.00 | 0.47 |
December | 0.354434E+09 | 0.00 | 0.00 | 582276.70 | 0.00 | 0.113395E+10 | 59056428.28 | 0.00 | 0.47 |
Annual Sum or Average | 0.255051E+10 | 0.357573E+10 | 2848798.94 | 49812568.35 | 0.206407E+09 | 0.596122E+10 | 0.417658E+10 | 75041.29 | 0.47 |
Minimum of Months | 26656.78 | 0.00 | 0.00 | 112562.81 | 0.00 | 146.74 | 1813823.34 | 0.00 | 0.47 |
Maximum of Months | 0.408108E+09 | 0.140507E+10 | 1226636.56 | 11132480.46 | 64206094.42 | 0.123599E+10 | 0.974720E+09 | 21993.82 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.250186E+09 | 0.00 | 0.00 | 124262.41 | 0.00 | 0.132814E+10 | 6971182.43 | 0.00 | 0.47 |
February | 0.254223E+09 | 0.00 | 0.00 | 212363.75 | 0.00 | 0.123417E+10 | 22698875.28 | 0.00 | 0.47 |
March | 0.429775E+09 | 1077.85 | 0.00 | 2133443.97 | 80051.19 | 0.101239E+10 | 0.186082E+09 | 0.00 | 0.47 |
April | 0.355856E+09 | 1435574.63 | 0.00 | 5132629.87 | 1834039.38 | 0.565936E+09 | 0.572147E+09 | 0.00 | 0.47 |
May | 0.214389E+09 | 28169144.48 | 29585.56 | 10183878.04 | 5838726.74 | 70472893.54 | 0.939623E+09 | 4601.30 | 0.47 |
June | 14644103.21 | 0.715519E+09 | 375593.97 | 4300281.56 | 53796135.40 | 102932.32 | 0.193706E+09 | 13936.65 | 0.48 |
July | 26653.65 | 0.139843E+10 | 918485.91 | 113319.97 | 70977654.09 | 146.72 | 1812840.47 | 18964.05 | 0.47 |
August | 5675425.59 | 0.975649E+09 | 612323.84 | 2375906.87 | 48570597.99 | 80202.64 | 74747677.46 | 23184.52 | 0.47 |
September | 90225458.36 | 0.354922E+09 | 579920.36 | 5093459.58 | 50137139.10 | 7285651.27 | 0.451604E+09 | 20848.18 | 0.47 |
October | 0.276772E+09 | 58591738.79 | 42527.31 | 5133664.11 | 18013517.29 | 0.282676E+09 | 0.707927E+09 | 5028.27 | 0.47 |
November | 0.413528E+09 | 0.00 | 0.00 | 541533.94 | 0.00 | 0.104752E+10 | 0.142058E+09 | 0.00 | 0.47 |
December | 0.307790E+09 | 0.00 | 0.00 | 92493.98 | 0.00 | 0.123726E+10 | 2699729.75 | 0.00 | 0.47 |
Annual Sum or Average | 0.261309E+10 | 0.353272E+10 | 2558436.94 | 35437238.05 | 0.249248E+09 | 0.678602E+10 | 0.330208E+10 | 86562.97 | 0.47 |
Minimum of Months | 26653.65 | 0.00 | 0.00 | 92493.98 | 0.00 | 146.72 | 1812840.47 | 0.00 | 0.47 |
Maximum of Months | 0.429775E+09 | 0.139843E+10 | 918485.91 | 10183878.04 | 70977654.09 | 0.132814E+10 | 0.939623E+09 | 23184.52 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.134212E+11 | 0.00 | 0.00 | 1311347.31 | 0.00 | 0.767761E+10 | 0.399338E+09 | 0.00 | 0.53 |
February | 0.164697E+11 | 0.00 | 0.00 | 6134944.18 | 0.00 | 0.296896E+10 | 0.104948E+10 | 0.00 | 0.53 |
March | 0.189000E+11 | 1100165.90 | 0.00 | 16564954.96 | 0.00 | 0.345252E+09 | 0.284716E+10 | 0.00 | 0.53 |
April | 0.165427E+11 | 44338228.43 | 0.00 | 20322876.39 | 0.00 | 0.00 | 0.376542E+10 | 0.00 | 0.54 |
May | 0.107996E+11 | 0.440897E+09 | 0.00 | 33074262.69 | 20736933.48 | 0.00 | 0.591025E+10 | 0.00 | 0.54 |
June | 0.137743E+10 | 0.969709E+10 | 0.00 | 15156865.35 | 0.740629E+09 | 0.00 | 0.149249E+10 | 0.00 | 0.54 |
July | 0.00 | 0.196543E+11 | 0.00 | 691818.26 | 0.284613E+09 | 0.00 | 25791681.73 | 0.00 | 0.54 |
August | 0.192600E+09 | 0.138805E+11 | 0.00 | 17051259.91 | 17215079.38 | 0.00 | 0.914249E+09 | 0.00 | 0.54 |
September | 0.297717E+10 | 0.536584E+10 | 0.00 | 46446645.69 | 0.135188E+09 | 0.00 | 0.449183E+10 | 0.00 | 0.54 |
October | 0.624910E+10 | 0.101999E+10 | 0.00 | 81508424.60 | 19472083.02 | 0.00 | 0.109255E+11 | 0.00 | 0.54 |
November | 0.171176E+11 | 0.00 | 0.00 | 24314879.51 | 0.00 | 0.189910E+09 | 0.441468E+10 | 0.00 | 0.54 |
December | 0.157318E+11 | 0.00 | 0.00 | 14355373.12 | 0.00 | 0.355769E+10 | 0.168596E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.119779E+12 | 0.501041E+11 | 0.00 | 0.276934E+09 | 0.121785E+10 | 0.147394E+11 | 0.379221E+11 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 691818.26 | 0.00 | 0.00 | 25791681.73 | 0.00 | 0.53 |
Maximum of Months | 0.189000E+11 | 0.196543E+11 | 0.00 | 81508424.60 | 0.740629E+09 | 0.767761E+10 | 0.109255E+11 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.560565E+10 | 0.00 | 0.00 | 4056399.21 | 0.00 | 0.139506E+11 | 0.194508E+10 | 0.00 | 0.53 |
February | 0.554248E+10 | 0.00 | 0.00 | 1831746.36 | 0.00 | 0.135923E+11 | 0.136330E+10 | 0.00 | 0.53 |
March | 0.621014E+10 | 14620.36 | 0.00 | 24664564.50 | 1085846.38 | 0.684424E+10 | 0.903603E+10 | 0.00 | 0.53 |
April | 0.539657E+10 | 10324357.25 | 67027.48 | 55464668.40 | 33953031.41 | 0.112894E+10 | 0.137530E+11 | 5936.49 | 0.54 |
May | 0.390529E+10 | 0.280290E+09 | 187766.58 | 89854283.94 | 0.181264E+09 | 39183467.56 | 0.127132E+11 | 18493.99 | 0.54 |
June | 0.345556E+09 | 0.793239E+10 | 3021409.56 | 31966660.33 | 0.250512E+10 | 1252294.20 | 0.250709E+10 | 47537.13 | 0.54 |
July | 1342130.99 | 0.167183E+11 | 5957708.97 | 1039467.75 | 0.322006E+10 | 0.00 | 24109143.12 | 36512.58 | 0.54 |
August | 99511846.19 | 0.112823E+11 | 8537066.70 | 16896832.66 | 0.261069E+10 | 144712.47 | 0.100765E+10 | 69559.22 | 0.54 |
September | 0.148733E+10 | 0.390638E+10 | 5305468.65 | 41818253.83 | 0.159081E+10 | 11283332.57 | 0.597707E+10 | 39627.99 | 0.54 |
October | 0.431940E+10 | 0.485255E+09 | 2304008.11 | 50924153.73 | 0.552160E+09 | 0.231151E+09 | 0.126593E+11 | 30127.57 | 0.54 |
November | 0.609370E+10 | 0.00 | 0.00 | 25704413.84 | 0.00 | 0.555339E+10 | 0.100797E+11 | 0.00 | 0.54 |
December | 0.584248E+10 | 0.00 | 0.00 | 4239674.63 | 0.00 | 0.130278E+11 | 0.212095E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.448495E+11 | 0.406152E+11 | 25380456.06 | 0.348461E+09 | 0.106951E+11 | 0.543802E+11 | 0.731866E+11 | 247794.97 | 0.54 |
Minimum of Months | 1342130.99 | 0.00 | 0.00 | 1039467.75 | 0.00 | 0.00 | 24109143.12 | 0.00 | 0.53 |
Maximum of Months | 0.621014E+10 | 0.167183E+11 | 8537066.70 | 89854283.94 | 0.322006E+10 | 0.139506E+11 | 0.137530E+11 | 69559.22 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.329702E+09 | 0.00 | 0.00 | 599618.69 | 0.00 | 0.120738E+10 | 47929788.74 | 0.00 | 0.47 |
February | 0.354689E+09 | 0.00 | 0.00 | 824418.12 | 0.00 | 0.106928E+10 | 86690113.31 | 0.00 | 0.47 |
March | 0.368933E+09 | 1077.97 | 0.00 | 4080000.09 | 80060.57 | 0.888074E+09 | 0.369480E+09 | 0.00 | 0.47 |
April | 0.272440E+09 | 2999778.45 | 0.00 | 7962215.60 | 270218.69 | 0.483071E+09 | 0.735775E+09 | 0.00 | 0.47 |
May | 0.150303E+09 | 30445233.03 | 14563.42 | 12036871.72 | 3585606.24 | 72996582.75 | 0.999477E+09 | 644.39 | 0.47 |
June | 6522095.58 | 0.726312E+09 | 193924.09 | 5048870.55 | 43280166.61 | 122237.03 | 0.201085E+09 | 8128.83 | 0.48 |
July | 0.00 | 0.142072E+10 | 169395.58 | 163733.47 | 49627965.69 | 0.00 | 1789456.18 | 6095.01 | 0.47 |
August | 1294966.30 | 0.998343E+09 | 34429.23 | 3116613.53 | 26595673.02 | 0.00 | 78477344.38 | 1769.85 | 0.47 |
September | 51199258.54 | 0.364428E+09 | 425843.31 | 8040692.10 | 40845577.73 | 5746064.18 | 0.489287E+09 | 8243.64 | 0.47 |
October | 0.147649E+09 | 72607889.29 | 35745.69 | 9943885.02 | 4016799.27 | 0.163944E+09 | 0.951122E+09 | 1359.46 | 0.47 |
November | 0.399382E+09 | 0.00 | 0.00 | 2657465.78 | 0.00 | 0.833248E+09 | 0.368545E+09 | 0.00 | 0.47 |
December | 0.366202E+09 | 0.00 | 0.00 | 961359.87 | 0.00 | 0.109726E+10 | 83598842.69 | 0.00 | 0.47 |
Annual Sum or Average | 0.244832E+10 | 0.361586E+10 | 873901.31 | 55435744.57 | 0.168302E+09 | 0.582111E+10 | 0.441326E+10 | 26241.18 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 163733.47 | 0.00 | 0.00 | 1789456.18 | 0.00 | 0.47 |
Maximum of Months | 0.399382E+09 | 0.142072E+10 | 425843.31 | 12036871.72 | 49627965.69 | 0.120738E+10 | 0.999477E+09 | 8243.64 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.234472E+09 | 0.00 | 0.00 | 143530.37 | 0.00 | 0.133565E+10 | 15162883.25 | 0.00 | 0.47 |
February | 0.259025E+09 | 0.00 | 0.00 | 206075.34 | 0.00 | 0.122259E+10 | 29483950.62 | 0.00 | 0.47 |
March | 0.436698E+09 | 1077.85 | 0.00 | 1633365.02 | 80051.19 | 0.101243E+10 | 0.179616E+09 | 0.00 | 0.47 |
April | 0.343117E+09 | 2663373.40 | 0.00 | 5598363.79 | 605893.47 | 0.553326E+09 | 0.597031E+09 | 347.14 | 0.47 |
May | 0.156188E+09 | 29972069.51 | 14543.43 | 11003350.03 | 4054782.55 | 81378024.28 | 0.986099E+09 | 662.59 | 0.47 |
June | 6709099.85 | 0.723502E+09 | 171011.76 | 4871410.67 | 46024873.13 | 82525.64 | 0.201090E+09 | 6117.14 | 0.48 |
July | 0.00 | 0.141767E+10 | 170593.81 | 163734.72 | 52499251.25 | 0.00 | 1789226.10 | 4876.22 | 0.47 |
August | 1589202.50 | 0.994122E+09 | 34893.61 | 2744618.08 | 30696858.06 | 0.00 | 78545391.98 | 1301.24 | 0.47 |
September | 63753530.95 | 0.360079E+09 | 512769.62 | 6027165.89 | 45055959.91 | 5939592.79 | 0.478488E+09 | 11973.75 | 0.47 |
October | 0.304281E+09 | 68728303.90 | 162266.74 | 5345101.01 | 7752375.91 | 0.280836E+09 | 0.682046E+09 | 9865.11 | 0.47 |
November | 0.410340E+09 | 0.00 | 0.00 | 935043.22 | 0.00 | 0.994269E+09 | 0.198101E+09 | 0.00 | 0.47 |
December | 0.295763E+09 | 0.00 | 0.00 | 191991.36 | 0.00 | 0.122396E+10 | 27919796.15 | 0.00 | 0.47 |
Annual Sum or Average | 0.251194E+10 | 0.359674E+10 | 1066078.98 | 38863749.50 | 0.186770E+09 | 0.671046E+10 | 0.347537E+10 | 35143.18 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 143530.37 | 0.00 | 0.00 | 1789226.10 | 0.00 | 0.47 |
Maximum of Months | 0.436698E+09 | 0.141767E+10 | 512769.62 | 11003350.03 | 52499251.25 | 0.133565E+10 | 0.986099E+09 | 11973.75 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.256523E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402976E+10 | 0.00 | 0.00 | 0.56 |
February | 0.243119E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262136E+10 | 0.00 | 0.00 | 0.56 |
March | 0.289275E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 12258454.02 | 0.00 | 0.00 | 0.55 |
April | 0.270453E+11 | 0.00 | 0.00 | 0.00 | 3951802.24 | 0.00 | 0.00 | 0.00 | 0.57 |
May | 0.227738E+11 | 0.00 | 0.00 | 14387.08 | 0.133237E+09 | 0.00 | 18568695.80 | 0.00 | 0.59 |
June | 0.604385E+10 | 0.960711E+09 | 0.00 | 617776.57 | 0.513627E+10 | 0.00 | 0.205812E+09 | 0.00 | 0.57 |
July | 0.116249E+09 | 0.725315E+10 | 0.00 | 787434.71 | 0.779761E+10 | 0.00 | 0.225455E+09 | 0.00 | 0.53 |
August | 0.215365E+10 | 0.733763E+10 | 0.00 | 4055634.30 | 0.202904E+10 | 0.00 | 0.166311E+10 | 0.00 | 0.56 |
September | 0.119619E+11 | 0.115044E+10 | 0.00 | 1185459.40 | 0.208364E+10 | 0.00 | 0.737016E+09 | 0.00 | 0.58 |
October | 0.240837E+11 | 0.00 | 0.00 | 0.00 | 0.232021E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
November | 0.286591E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 27728132.58 | 0.00 | 0.00 | 0.55 |
December | 0.271733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127339E+10 | 0.00 | 0.00 | 0.56 |
Annual Sum or Average | 0.228903E+12 | 0.167019E+11 | 0.00 | 6660692.06 | 0.174158E+11 | 0.796450E+10 | 0.284996E+10 | 0.00 | 0.56 |
Minimum of Months | 0.116249E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.289275E+11 | 0.733763E+10 | 0.00 | 4055634.30 | 0.779761E+10 | 0.402976E+10 | 0.166311E+10 | 0.00 | 0.59 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 62977744.84 | 0.00 | 0.00 | 119038.72 | 0.00 | 0.327042E+09 | 6263967.02 | 0.00 | 0.47 |
February | 69882999.71 | 0.00 | 0.00 | 226006.38 | 0.00 | 0.294311E+09 | 13449257.73 | 0.00 | 0.47 |
March | 89737627.43 | 18306.49 | 0.00 | 1094833.53 | 1978.14 | 0.246971E+09 | 69838423.85 | 0.00 | 0.47 |
April | 75117304.60 | 573486.59 | 0.00 | 1668402.00 | 244012.69 | 0.155671E+09 | 0.142356E+09 | 0.00 | 0.47 |
May | 44688011.61 | 7220427.53 | 7480.91 | 2603433.24 | 1282536.53 | 41825888.03 | 0.219586E+09 | 1066.81 | 0.47 |
June | 3274543.29 | 0.179596E+09 | 104266.52 | 1052979.26 | 12745010.87 | 58858.34 | 48808083.68 | 3818.89 | 0.48 |
July | 9795.33 | 0.350919E+09 | 326414.36 | 24392.66 | 16377975.36 | 36.68 | 454072.74 | 6566.32 | 0.47 |
August | 1327751.00 | 0.246188E+09 | 191683.27 | 631107.69 | 9859308.82 | 15581.78 | 18747790.58 | 5048.47 | 0.47 |
September | 17156065.43 | 90240149.34 | 123146.89 | 1569676.95 | 11059161.40 | 4980851.69 | 0.114862E+09 | 4362.76 | 0.47 |
October | 51925989.86 | 17760219.10 | 0.00 | 1821028.47 | 1405229.32 | 76091297.39 | 0.188326E+09 | 0.00 | 0.47 |
November | 96438213.12 | 0.00 | 0.00 | 317828.79 | 0.00 | 0.251958E+09 | 52244082.40 | 0.00 | 0.47 |
December | 76494343.10 | 0.00 | 0.00 | 135162.72 | 0.00 | 0.301683E+09 | 8691911.06 | 0.00 | 0.47 |
Annual Sum or Average | 0.589030E+09 | 0.892515E+09 | 752991.96 | 11263890.41 | 52975213.13 | 0.170061E+10 | 0.883627E+09 | 20863.24 | 0.47 |
Minimum of Months | 9795.33 | 0.00 | 0.00 | 24392.66 | 0.00 | 36.68 | 454072.74 | 0.00 | 0.47 |
Maximum of Months | 96438213.12 | 0.350919E+09 | 326414.36 | 2603433.24 | 16377975.36 | 0.327042E+09 | 0.219586E+09 | 6566.32 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 35931139.62 | 0.00 | 0.00 | 37379.73 | 0.00 | 0.358984E+09 | 1404247.38 | 0.00 | 0.47 |
February | 45446198.84 | 0.00 | 0.00 | 47186.60 | 0.00 | 0.328184E+09 | 4148166.07 | 0.00 | 0.47 |
March | 96962207.90 | 269.46 | 0.00 | 494545.74 | 20012.80 | 0.275116E+09 | 35020812.62 | 0.00 | 0.47 |
April | 86102610.60 | 371219.91 | 0.00 | 1178681.34 | 446183.59 | 0.171485E+09 | 0.116002E+09 | 0.00 | 0.47 |
May | 51685435.91 | 7115473.83 | 7470.62 | 2359742.70 | 1386493.97 | 44626565.42 | 0.209995E+09 | 1076.10 | 0.47 |
June | 3609246.00 | 0.178437E+09 | 91837.97 | 1010643.37 | 13893576.38 | 63527.61 | 48504815.09 | 3670.69 | 0.48 |
July | 9794.19 | 0.349447E+09 | 295735.38 | 24446.56 | 17837918.18 | 36.68 | 453962.78 | 6150.97 | 0.47 |
August | 1437730.96 | 0.243646E+09 | 191018.28 | 542920.11 | 12371346.13 | 4620.63 | 18734531.45 | 5690.40 | 0.47 |
September | 22076192.70 | 88440870.78 | 161787.52 | 1097306.18 | 12807081.33 | 10466959.05 | 0.104912E+09 | 5197.12 | 0.47 |
October | 71568552.36 | 14760982.06 | 15662.94 | 945470.09 | 4384673.28 | 0.119051E+09 | 0.126563E+09 | 1884.64 | 0.47 |
November | 87694617.85 | 0.00 | 0.00 | 108798.36 | 0.00 | 0.297840E+09 | 15268312.39 | 0.00 | 0.47 |
December | 51529205.92 | 0.00 | 0.00 | 42169.89 | 0.00 | 0.334465E+09 | 923167.11 | 0.00 | 0.47 |
Annual Sum or Average | 0.554053E+09 | 0.882219E+09 | 763512.71 | 7889290.66 | 63147285.67 | 0.194029E+10 | 0.681930E+09 | 23669.92 | 0.47 |
Minimum of Months | 9794.19 | 0.00 | 0.00 | 24446.56 | 0.00 | 36.68 | 453962.78 | 0.00 | 0.47 |
Maximum of Months | 96962207.90 | 0.349447E+09 | 295735.38 | 2359742.70 | 17837918.18 | 0.358984E+09 | 0.209995E+09 | 6150.97 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.459472E+09 | 0.00 | 0.00 | 4607333.37 | 0.00 | 0.170139E+10 | 0.381219E+09 | 0.00 | 0.53 |
February | 0.401241E+09 | 0.00 | 0.00 | 6773270.66 | 0.00 | 0.140934E+10 | 0.610263E+09 | 0.00 | 0.54 |
March | 0.461819E+09 | 130318.43 | 0.00 | 12308119.23 | 0.00 | 0.111071E+10 | 0.103405E+10 | 0.00 | 0.53 |
April | 0.437157E+09 | 4434136.12 | 0.00 | 11593019.35 | 817879.32 | 0.653601E+09 | 0.130562E+10 | 0.00 | 0.54 |
May | 0.293536E+09 | 44979659.86 | 47534.46 | 13665524.40 | 9649721.47 | 60288153.00 | 0.161577E+10 | 5200.84 | 0.54 |
June | 26281626.71 | 0.113732E+10 | 479353.02 | 5116042.29 | 98562704.73 | 261616.90 | 0.310088E+09 | 21721.16 | 0.54 |
July | 62930.02 | 0.223144E+10 | 1313182.26 | 143657.23 | 0.129047E+09 | 235.68 | 2930238.61 | 35300.55 | 0.54 |
August | 8252953.24 | 0.157365E+10 | 482942.77 | 3758232.59 | 72075314.81 | 128830.35 | 0.120990E+09 | 25069.16 | 0.54 |
September | 0.103311E+09 | 0.579434E+09 | 400915.39 | 12181709.48 | 71775284.64 | 4694115.60 | 0.770044E+09 | 5474.19 | 0.54 |
October | 0.223617E+09 | 0.117860E+09 | 37804.78 | 21056295.69 | 5227151.12 | 0.115861E+09 | 0.168351E+10 | 3051.81 | 0.54 |
November | 0.492999E+09 | 0.00 | 0.00 | 9686650.23 | 0.00 | 0.100823E+10 | 0.106504E+10 | 0.00 | 0.54 |
December | 0.442418E+09 | 0.00 | 0.00 | 8815683.07 | 0.00 | 0.142828E+10 | 0.606794E+09 | 0.00 | 0.54 |
Annual Sum or Average | 0.335017E+10 | 0.568925E+10 | 2761732.70 | 0.109706E+09 | 0.387155E+09 | 0.749279E+10 | 0.950632E+10 | 95817.72 | 0.54 |
Minimum of Months | 62930.02 | 0.00 | 0.00 | 143657.23 | 0.00 | 235.68 | 2930238.61 | 0.00 | 0.53 |
Maximum of Months | 0.492999E+09 | 0.223144E+10 | 1313182.26 | 21056295.69 | 0.129047E+09 | 0.170139E+10 | 0.168351E+10 | 35300.55 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.118616E+11 | 0.00 | 0.00 | 43257091.51 | 0.00 | 0.00 | 0.328863E+11 | 0.00 | 3.98 |
February | 0.103072E+11 | 0.00 | 0.00 | 33033807.91 | 0.00 | 0.00 | 0.299349E+11 | 0.00 | 3.99 |
March | 0.532038E+10 | 0.00 | 0.00 | 81972657.29 | 0.00 | 0.00 | 0.412654E+11 | 0.00 | 4.17 |
April | 0.231610E+10 | 5912676.99 | 0.00 | 89233833.02 | 0.00 | 0.00 | 0.431329E+11 | 0.00 | 4.43 |
May | 0.116280E+09 | 0.214074E+09 | 0.00 | 90021895.47 | 152194.84 | 0.00 | 0.412664E+11 | 0.00 | 4.91 |
June | 0.00 | 0.110503E+11 | 0.00 | 42160950.39 | 0.00 | 0.00 | 0.122427E+11 | 0.00 | 5.04 |
July | 0.00 | 0.283904E+11 | 0.00 | 4805032.65 | 0.00 | 0.00 | 0.693571E+09 | 0.00 | 4.77 |
August | 0.00 | 0.170539E+11 | 0.00 | 31997567.24 | 0.00 | 0.00 | 0.765134E+10 | 0.00 | 4.95 |
September | 33302249.03 | 0.581306E+10 | 0.00 | 57458623.83 | 0.00 | 0.00 | 0.231743E+11 | 0.00 | 4.93 |
October | 0.101233E+10 | 0.346602E+09 | 0.00 | 84016956.37 | 5069721.65 | 0.00 | 0.402537E+11 | 0.00 | 4.61 |
November | 0.590983E+10 | 0.00 | 0.00 | 77471354.66 | 0.00 | 0.00 | 0.402333E+11 | 0.00 | 4.16 |
December | 0.906146E+10 | 0.00 | 0.00 | 49698407.17 | 0.00 | 0.00 | 0.342764E+11 | 0.00 | 4.02 |
Annual Sum or Average | 0.459385E+11 | 0.628743E+11 | 0.00 | 0.685128E+09 | 5221916.49 | 0.00 | 0.347011E+12 | 0.00 | 4.50 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 4805032.65 | 0.00 | 0.00 | 0.693571E+09 | 0.00 | 3.98 |
Maximum of Months | 0.118616E+11 | 0.283904E+11 | 0.00 | 90021895.47 | 5069721.65 | 0.00 | 0.431329E+11 | 0.00 | 5.04 |
Report: MechanicalVentilationLoadsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.719432E+10 | 0.00 | 0.00 | 59926869.13 | 0.00 | 0.00 | 0.409952E+11 | 0.00 | 4.29 |
February | 0.662317E+10 | 0.00 | 0.00 | 46778536.17 | 0.00 | 0.00 | 0.367180E+11 | 0.00 | 4.29 |
March | 0.226417E+10 | 0.00 | 0.00 | 0.108182E+09 | 0.00 | 0.00 | 0.485704E+11 | 0.00 | 4.54 |
April | 0.805596E+09 | 6393887.80 | 0.00 | 0.111335E+09 | 0.00 | 0.00 | 0.486420E+11 | 0.00 | 4.81 |
May | 12928494.81 | 0.230616E+09 | 0.00 | 0.102134E+09 | 0.00 | 0.00 | 0.447430E+11 | 0.00 | 5.31 |
June | 0.00 | 0.117957E+11 | 0.00 | 45670438.44 | 0.00 | 0.00 | 0.130269E+11 | 0.00 | 5.38 |
July | 0.00 | 0.301709E+11 | 0.00 | 5077109.04 | 0.00 | 0.00 | 0.729112E+09 | 0.00 | 5.06 |
August | 0.00 | 0.181116E+11 | 0.00 | 34454445.42 | 0.00 | 0.00 | 0.807365E+10 | 0.00 | 5.25 |
September | 1647149.50 | 0.620072E+10 | 0.00 | 64077331.14 | 0.00 | 0.00 | 0.248852E+11 | 0.00 | 5.27 |
October | 0.298857E+09 | 0.377115E+09 | 0.00 | 99038626.47 | 0.00 | 0.00 | 0.442104E+11 | 0.00 | 4.96 |
November | 0.244396E+10 | 0.00 | 0.00 | 0.101598E+09 | 0.00 | 0.00 | 0.477358E+11 | 0.00 | 4.51 |
December | 0.339700E+10 | 0.00 | 0.00 | 68771393.19 | 0.00 | 0.00 | 0.437210E+11 | 0.00 | 4.36 |
Annual Sum or Average | 0.230416E+11 | 0.668930E+11 | 0.00 | 0.847043E+09 | 0.00 | 0.00 | 0.402051E+12 | 0.00 | 4.84 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 5077109.04 | 0.00 | 0.00 | 0.729112E+09 | 0.00 | 4.29 |
Maximum of Months | 0.719432E+10 | 0.301709E+11 | 0.00 | 0.111335E+09 | 0.00 | 0.00 | 0.486420E+11 | 0.00 | 5.38 |
Report: MechanicalVentilationLoadsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 37185826.17 | 0.00 | 0.00 | 0.147168E+09 | 0.00 | 0.00 | 0.650354E+11 | 0.00 | 18.70 |
February | 22089806.36 | 0.00 | 0.00 | 0.124644E+09 | 0.00 | 0.00 | 0.593511E+11 | 0.00 | 18.95 |
March | 39651122.76 | 0.00 | 0.00 | 0.200072E+09 | 0.00 | 0.00 | 0.663128E+11 | 0.00 | 19.39 |
April | 40464280.72 | 11264844.79 | 0.00 | 0.175635E+09 | 0.00 | 0.00 | 0.621253E+11 | 0.00 | 20.30 |
May | 38845820.02 | 0.380269E+09 | 0.00 | 0.127937E+09 | 0.00 | 0.00 | 0.520831E+11 | 0.00 | 21.83 |
June | 0.00 | 0.159647E+11 | 0.00 | 54672527.69 | 0.00 | 0.00 | 0.135654E+11 | 0.00 | 21.17 |
July | 0.00 | 0.377019E+11 | 0.00 | 4923060.98 | 0.00 | 0.00 | 0.655407E+09 | 0.00 | 19.72 |
August | 0.00 | 0.236241E+11 | 0.00 | 40239177.66 | 0.00 | 0.00 | 0.767869E+10 | 0.00 | 20.55 |
September | 2172050.35 | 0.824874E+10 | 0.00 | 84246285.18 | 0.00 | 0.00 | 0.284169E+11 | 0.00 | 21.48 |
October | 81205672.00 | 0.659619E+09 | 0.00 | 0.144215E+09 | 0.00 | 0.00 | 0.548495E+11 | 0.00 | 20.96 |
November | 0.108596E+09 | 0.00 | 0.00 | 0.182333E+09 | 0.00 | 0.00 | 0.651738E+11 | 0.00 | 19.29 |
December | 17368645.33 | 0.00 | 0.00 | 0.157129E+09 | 0.00 | 0.00 | 0.632217E+11 | 0.00 | 18.94 |
Annual Sum or Average | 0.387579E+09 | 0.865906E+11 | 0.00 | 0.144321E+10 | 0.00 | 0.00 | 0.538469E+12 | 0.00 | 20.11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 4923060.98 | 0.00 | 0.00 | 0.655407E+09 | 0.00 | 18.70 |
Maximum of Months | 0.108596E+09 | 0.377019E+11 | 0.00 | 0.200072E+09 | 0.00 | 0.00 | 0.663128E+11 | 0.00 | 21.83 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.111717E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411425E+10 | 0.00 | 0.00 | 1.09 |
February | 0.100749E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379549E+10 | 0.00 | 0.00 | 1.10 |
March | 0.147390E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164645E+09 | 0.00 | 0.00 | 1.08 |
April | 0.139122E+11 | 0.00 | 0.00 | 19592.68 | 2035134.64 | 0.00 | 15788949.17 | 0.00 | 1.10 |
May | 0.116224E+11 | 64578226.35 | 0.00 | 238615.88 | 8562951.19 | 0.00 | 0.115187E+09 | 0.00 | 1.15 |
June | 0.261348E+10 | 0.205671E+10 | 0.00 | 1277346.22 | 0.115570E+10 | 0.00 | 0.605370E+09 | 0.00 | 1.13 |
July | 54738887.45 | 0.679203E+10 | 0.00 | 429363.95 | 0.136484E+10 | 0.00 | 0.119697E+09 | 0.00 | 1.08 |
August | 0.123397E+10 | 0.484908E+10 | 0.00 | 2622443.80 | 0.376636E+09 | 0.00 | 0.720609E+09 | 0.00 | 1.15 |
September | 0.585582E+10 | 0.848922E+09 | 0.00 | 1729350.00 | 0.850829E+09 | 0.00 | 0.684987E+09 | 0.00 | 1.15 |
October | 0.123494E+11 | 55994792.63 | 0.00 | 45980.66 | 63493693.01 | 0.00 | 53435165.64 | 0.00 | 1.12 |
November | 0.143795E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.393867E+09 | 0.00 | 0.00 | 1.07 |
December | 0.138569E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.792817E+09 | 0.00 | 0.00 | 1.09 |
Annual Sum or Average | 0.111864E+12 | 0.146673E+11 | 0.00 | 6362693.19 | 0.382210E+10 | 0.926107E+10 | 0.231507E+10 | 0.00 | 1.11 |
Minimum of Months | 54738887.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 |
Maximum of Months | 0.147390E+11 | 0.679203E+10 | 0.00 | 2622443.80 | 0.136484E+10 | 0.411425E+10 | 0.720609E+09 | 0.00 | 1.15 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:59:43
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.141688E+12 | 0.202491E+11 | 0.253798E+12 | 0.103743E+13 | 0.784514E+11 |
February | 0.233127E+12 | 0.193764E+11 | 0.240357E+12 | 0.993798E+12 | 0.708532E+11 |
March | 0.417057E+12 | 0.165145E+11 | 0.208643E+12 | 0.862918E+12 | 0.776675E+11 |
April | 0.444255E+12 | 0.113490E+11 | 0.144428E+12 | 0.608279E+12 | 0.140587E+12 |
May | 0.572562E+12 | 0.723331E+10 | 0.886016E+11 | 0.404210E+12 | 0.322813E+12 |
June | 0.568509E+12 | -0.227527E+10 | -0.171036E+11 | -0.676713E+11 | 0.987834E+12 |
July | 0.540581E+12 | -0.962532E+10 | -0.109368E+12 | -0.488402E+12 | 0.146948E+13 |
August | 0.515805E+12 | -0.558824E+10 | -0.685333E+11 | -0.283944E+12 | 0.126554E+13 |
September | 0.354700E+12 | 0.169621E+10 | 0.274823E+11 | 0.128387E+12 | 0.728301E+12 |
October | 0.342086E+12 | 0.856249E+10 | 0.105015E+12 | 0.476980E+12 | 0.332032E+12 |
November | 0.166805E+12 | 0.143391E+11 | 0.183493E+12 | 0.762881E+12 | 0.803258E+11 |
December | 0.114099E+12 | 0.182674E+11 | 0.235464E+12 | 0.957195E+12 | 0.719396E+11 |
Annual Sum or Average | 0.441128E+13 | 0.100099E+12 | 0.129228E+13 | 0.539207E+13 | 0.562582E+13 |
Minimum of Months | 0.114099E+12 | -0.962532E+10 | -0.109368E+12 | -0.488402E+12 | 0.708532E+11 |
Maximum of Months | 0.572562E+12 | 0.202491E+11 | 0.253798E+12 | 0.103743E+13 | 0.146948E+13 |