Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:59

Tabular Output Report in Format: HTML

Building: HotelLarge

Environment: RUNPERIOD 1 ** Fairbanks Intl Arpt AK USA TMY3 WMO#=702610

Simulation Timestamp: 2023-10-16 08:59:07


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 15620.69 1376.84 1376.84
Net Site Energy 15620.69 1376.84 1376.84
Total Source Energy 26897.18 2370.78 2370.78
Net Source Energy 26897.18 2370.78 2370.78


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 11345.29
Net Conditioned Building Area 11345.29
Unconditioned Building Area 0.00


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 5420.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 326.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 766.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 240.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1745.01 1788.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 651.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 553.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 101.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 245.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 90.75 3627.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9857.19
Refrigeration 60.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 4783.66 10837.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9857.19
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler 0.00 5420.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 326.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 766.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 240.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 959.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Cooking 762.04 1198.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ReachInFreezer 14.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ReachInRefrigerator 8.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Laundry 0.00 590.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Transformer 32.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLift 616.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 2.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 553.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 101.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 245.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 90.75 3627.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5742.51
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4114.69
Refrigeration General 7.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  LowTempRefrigeration 20.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  MedTempRefrigeration 33.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 0.00 5420.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 326.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GENERAL 766.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 240.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 1745.01 1788.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 651.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 553.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 101.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 245.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 90.75 3627.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9857.19
Refrigeration Unassigned 60.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 88.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 94.57 797.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.87
Other 238.27 157.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 421.64 955.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.87


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 88.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 94.57 797.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.87
Other 238.27 157.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 421.64 955.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.87


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 4783.656 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 4783.656 100.00
     
Total On-Site and Utility Electric Sources 4783.656 100.00
Total Electricity End Uses 4783.656 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00 0.00
Air to Air Heat Recovery for Cooling 2.19 0.03
Air to Air Heat Recovery for Heating 6296.90 99.97
High-Temperature Geothermal* 0.00 0.00
Solar Water Thermal 0.00 0.00
Solar Air Thermal 0.00 0.00
Total On-Site Thermal Sources 6299.09 100.00


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 9857.19 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 9857.19 100.00
Total Water End Uses 9857.19 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 51.17
Time Setpoint Not Met During Occupied Cooling 297.17
Time Not Comfortable Based on Simple ASHRAE 55-2004 7978.67


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 8

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AK_FAIRBANKS

| Environment |

ZoneCoolingSummaryMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

ZoneHeatingSummaryMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

ZoneElectricSummaryMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

SpaceGainsMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

PeakSpaceGainsMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

SpaceGainComponentsAtCoolingPeakMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

ComfortReportSimple55Monthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

OccupantComfortDataSummaryMonthly

| BASEMENT PEOPLE | RETAIL_1_FLR_1 PEOPLE | RETAIL_2_FLR_1 PEOPLE | LAUNDRY_FLR_1 PEOPLE | CAFE_FLR_1 PEOPLE | LOBBY_FLR_1 PEOPLE | ROOM_1_FLR_3 PEOPLE | ROOM_2_FLR_3 PEOPLE | ROOM_3_MULT19_FLR_3 PEOPLE | ROOM_4_MULT19_FLR_3 PEOPLE | ROOM_5_FLR_3 PEOPLE | ROOM_6_FLR_3 PEOPLE | ROOM_1_FLR_6 PEOPLE | ROOM_2_FLR_6 PEOPLE | ROOM_3_MULT9_FLR_6 PEOPLE | BANQUET_FLR_6 PEOPLE | DINING_FLR_6 PEOPLE | KITCHEN_FLR_6 PEOPLE | STORAGE_FLR_1 PEOPLE | CORRIDOR_FLR_3 PEOPLE | CORRIDOR_FLR_6 PEOPLE | MECH_FLR_1 PEOPLE |

ChillerReportMonthly

| COOLSYS1 CHILLER1 |

BoilerReportMonthly

| HEATSYS1 BOILER |

DXReportMonthly

| VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |

WindowReportMonthly

| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |

WindowEnergyReportMonthly

| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |

WindowZoneSummaryMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

WindowEnergyZoneSummaryMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWH BOOSTER E WATER HEATER | SWH LAUNDRY G WATER HEATER | SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| LOBBY_FLR_1_DAYLCTRL | CAFE_FLR_1_DAYLCTRL | DINING_FLR_6_DAYLCTRL | BANQUET_FLR_6_DAYLCTRL |

CoilReportMonthly

| VAV WITH REHEAT HEATING COIL | BASEMENT VAV BOX REHEAT COIL | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | MECH_FLR_1 VAV BOX REHEAT COIL | STORAGE_FLR_1 VAV BOX REHEAT COIL | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | CAFE_FLR_1 VAV BOX REHEAT COIL | LOBBY_FLR_1 VAV BOX REHEAT COIL | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | BANQUET_FLR_6 VAV BOX REHEAT COIL | DINING_FLR_6 VAV BOX REHEAT COIL | KITCHEN_FLR_6 VAV BOX REHEAT COIL | FLR_3_DOAS HEATING COIL | ROOM_1_FLR_3 FAN COIL HEATING COIL | ROOM_2_FLR_3 FAN COIL HEATING COIL | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_5_FLR_3 FAN COIL HEATING COIL | ROOM_6_FLR_3 FAN COIL HEATING COIL | ROOM_1_FLR_6 FAN COIL HEATING COIL | ROOM_2_FLR_6 FAN COIL HEATING COIL | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |

PlantLoopDemandReportMonthly

| HEATSYS1 | COOLSYS1 | SWHSYS1 |

FanReportMonthly

| FLR_3_DOAS FAN | VAV WITH REHEAT FAN | LAUNDRY_FLR_1 EXHAUST FAN | LOBBY_FLR_1 EXHAUST FAN | BANQUET_FLR_6 EXHAUST FAN | DINING_FLR_6 EXHAUST FAN | KITCHEN_FLR_6 EXHAUST FAN | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN |

PumpReportMonthly

| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | COOLSYS1 PUMP | SWHSYS1 PUMP |

CondLoopDemandReportMonthly

| HEATSYS1 | COOLSYS1 | SWHSYS1 |

ZoneTemperatureOscillationReportMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

AirLoopSystemEnergyAndWaterUseMonthly

| VAV WITH REHEAT | FLR_3_DOAS |

AirLoopSystemComponentLoadsMonthly

| VAV WITH REHEAT | FLR_3_DOAS |

AirLoopSystemComponentEnergyUseMonthly

| VAV WITH REHEAT | FLR_3_DOAS |

MechanicalVentilationLoadsMonthly

| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:59
RunPeriod RUNPERIOD 1
Weather File Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Latitude [deg] 64.82
Longitude [deg] -147.8
Elevation [m] 133.00
Time Zone -9.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 4559.59 1873.43 406.47 1873.22 406.47
Above Ground Wall Area [m2] 4025.82 1662.30 350.71 1662.10 350.71
Window Opening Area [m2] 1213.79 432.95 85.85 609.15 85.85
Gross Window-Wall Ratio [%] 26.62 23.11 21.12 32.52 21.12
Above Ground Window-Wall Ratio [%] 30.15 26.05 24.48 36.65 24.48


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 4559.59 1873.43 406.47 1873.22 406.47
Above Ground Wall Area [m2] 4025.82 1662.30 350.71 1662.10 350.71
Window Opening Area [m2] 1213.79 432.95 85.85 609.15 85.85
Gross Window-Wall Ratio [%] 26.62 23.11 21.12 32.52 21.12
Above Ground Window-Wall Ratio [%] 30.15 26.05 24.48 36.65 24.48


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 1978.84
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
BASEMENT 1978.83 Yes Yes 4826.41 1.00 0.00 533.77 0.00 0.00 9.1389 18.58 5.3800
RETAIL_1_FLR_1 67.07 Yes Yes 265.76 1.00 68.84 0.00 23.26 23.26 13.3365 6.19 10.7600
RETAIL_2_FLR_1 77.67 Yes Yes 307.76 1.00 26.57 0.00 0.00 0.00 13.3365 6.19 10.7600
MECH_FLR_1 164.24 Yes Yes 650.80 1.00 62.80 0.00 0.00 0.00 9.2031 61.93 5.3800
STORAGE_FLR_1 94.76 Yes Yes 375.47 1.00 36.23 0.00 0.00 0.00 6.1031 46.45 2.6900
LAUNDRY_FLR_1 78.04 Yes Yes 309.22 1.00 85.75 0.00 0.00 0.00 5.8125 9.29 597.5300
CAFE_FLR_1 188.86 Yes Yes 748.35 1.00 152.17 0.00 65.50 65.50 10.3656 1.33 5.3800
LOBBY_FLR_1 1308.19 Yes Yes 5183.56 1.00 434.79 0.00 85.08 85.08 8.7188 3.10 8.0700
ROOM_1_FLR_3 39.02 Yes Yes 118.94 4.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
ROOM_2_FLR_3 39.02 Yes Yes 118.93 4.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
ROOM_3_MULT19_FLR_3 24.52 Yes Yes 74.75 76.00 11.15 0.00 3.68 3.68 4.5531 16.35 10.5200
ROOM_4_MULT19_FLR_3 24.53 Yes Yes 74.77 76.00 11.15 0.00 3.68 3.68 4.5531 16.35 10.5200
ROOM_5_FLR_3 39.02 Yes Yes 118.94 4.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
ROOM_6_FLR_3 39.02 Yes Yes 118.93 4.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
CORRIDOR_FLR_3 389.40 Yes Yes 1186.91 4.00 48.31 0.00 15.94 15.94 6.3938 18.58 0.0000
ROOM_1_FLR_6 39.02 Yes Yes 118.94 1.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
ROOM_2_FLR_6 39.02 Yes Yes 118.93 1.00 39.95 0.00 13.18 13.18 4.5531 26.01 6.7500
ROOM_3_MULT9_FLR_6 24.53 Yes Yes 74.77 9.00 20.44 0.00 6.74 6.74 4.5531 16.35 10.5200
BANQUET_FLR_6 331.66 Yes Yes 1010.89 1.00 97.55 0.00 32.19 32.19 10.3656 1.33 67.8200
DINING_FLR_6 331.66 Yes Yes 1010.89 1.00 97.55 0.00 32.19 32.19 10.3656 1.33 67.8200
KITCHEN_FLR_6 103.30 Yes Yes 314.87 1.00 87.33 0.00 26.37 26.37 11.7219 4.65 2934.4875
CORRIDOR_FLR_6 412.12 Yes Yes 1256.16 1.00 85.47 0.00 28.20 28.20 6.3938 18.58 0.0000
Total 11345.29     35184.81   4025.82 533.77 1213.79 1213.79 6.8557 7.07 41.0709
Conditioned Total 11345.29     35184.81   4025.82 533.77 1213.79 1213.79 6.8557 7.07 41.0709
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
BASEMENT 1978.83 Yes Yes 1.00 BASEMENT GENERAL BASEMENT 9.1389 18.58 5.3800  
RETAIL_1_FLR_1 67.07 Yes Yes 1.00 RETAIL_1_FLR_1 GENERAL RETAIL_1_FLR_1 13.3365 6.19 10.7600  
RETAIL_2_FLR_1 77.67 Yes Yes 1.00 RETAIL_2_FLR_1 GENERAL RETAIL_2_FLR_1 13.3365 6.19 10.7600  
MECH_FLR_1 164.24 Yes Yes 1.00 MECH_FLR_1 GENERAL MECH_FLR_1 9.2031 61.93 5.3800  
STORAGE_FLR_1 94.76 Yes Yes 1.00 STORAGE_FLR_1 GENERAL STORAGE_FLR_1 6.1031 46.45 2.6900  
LAUNDRY_FLR_1 78.04 Yes Yes 1.00 LAUNDRY_FLR_1 GENERAL LAUNDRY_FLR_1 5.8125 9.29 597.5300  
CAFE_FLR_1 188.86 Yes Yes 1.00 CAFE_FLR_1 GENERAL CAFE_FLR_1 10.3656 1.33 5.3800  
LOBBY_FLR_1 1308.19 Yes Yes 1.00 LOBBY_FLR_1 GENERAL LOBBY_FLR_1 8.7188 3.10 8.0700  
ROOM_1_FLR_3 39.02 Yes Yes 4.00 ROOM_1_FLR_3 GENERAL ROOM_1_FLR_3 4.5531 26.01 6.7500  
ROOM_2_FLR_3 39.02 Yes Yes 4.00 ROOM_2_FLR_3 GENERAL ROOM_2_FLR_3 4.5531 26.01 6.7500  
ROOM_3_MULT19_FLR_3 24.52 Yes Yes 76.00 ROOM_3_MULT19_FLR_3 GENERAL ROOM_3_MULT19_FLR_3 4.5531 16.35 10.5200  
ROOM_4_MULT19_FLR_3 24.53 Yes Yes 76.00 ROOM_4_MULT19_FLR_3 GENERAL ROOM_4_MULT19_FLR_3 4.5531 16.35 10.5200  
ROOM_5_FLR_3 39.02 Yes Yes 4.00 ROOM_5_FLR_3 GENERAL ROOM_5_FLR_3 4.5531 26.01 6.7500  
ROOM_6_FLR_3 39.02 Yes Yes 4.00 ROOM_6_FLR_3 GENERAL ROOM_6_FLR_3 4.5531 26.01 6.7500  
CORRIDOR_FLR_3 389.40 Yes Yes 4.00 CORRIDOR_FLR_3 GENERAL CORRIDOR_FLR_3 6.3938 18.58 0.0000  
ROOM_1_FLR_6 39.02 Yes Yes 1.00 ROOM_1_FLR_6 GENERAL ROOM_1_FLR_6 4.5531 26.01 6.7500  
ROOM_2_FLR_6 39.02 Yes Yes 1.00 ROOM_2_FLR_6 GENERAL ROOM_2_FLR_6 4.5531 26.01 6.7500  
ROOM_3_MULT9_FLR_6 24.53 Yes Yes 9.00 ROOM_3_MULT9_FLR_6 GENERAL ROOM_3_MULT9_FLR_6 4.5531 16.35 10.5200  
BANQUET_FLR_6 331.66 Yes Yes 1.00 BANQUET_FLR_6 GENERAL BANQUET_FLR_6 10.3656 1.33 67.8200  
DINING_FLR_6 331.66 Yes Yes 1.00 DINING_FLR_6 GENERAL DINING_FLR_6 10.3656 1.33 67.8200  
KITCHEN_FLR_6 103.30 Yes Yes 1.00 KITCHEN_FLR_6 GENERAL KITCHEN_FLR_6 11.7219 4.65 2934.4875  
CORRIDOR_FLR_6 412.12 Yes Yes 1.00 CORRIDOR_FLR_6 GENERAL CORRIDOR_FLR_6 6.3938 18.58 0.0000  
Total 11345.29             6.8557 3.54 41.0709  
Conditioned Total 11345.29             6.8557 3.54 41.0709  
Unconditioned Total 0.00             0.0000 0.00 0.0000  
Not Part of Total 0.00             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 11345.29 11345.29 0.00 0.00 4.4542 8.82 37.1989
Total 11345.29 11345.29 0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 20-JUN-19:10 12-JAN-17:00 - - - - - - - - - - 12-APR-20:10
Heating 0.00 1241198.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 102862.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 60249.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 88772.42 89612.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 32148.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 30526.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 7796.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 9938.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 3678.72 266446.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 1854.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 337827.26 1597257.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler 0.00 1241198.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 102862.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 60249.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 58789.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Cooking 29240.64 74976.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ReachInFreezer 457.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ReachInRefrigerator 285.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Laundry 0.00 14636.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Transformer 1844.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLift 30153.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 150.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 30526.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 7796.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 9938.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 3678.72 266446.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 241.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  LowTempRefrigeration 533.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  MedTempRefrigeration 1079.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 5875.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 1035.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 2427.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 762.79 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 5526.46 1939.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 2063.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 1753.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 322.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 778.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 287.41 3932.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 193.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 15149.84 11747.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 517.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 91.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 213.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 67.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 487.11 170.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 181.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 154.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 28.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 68.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 25.33 346.62 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 17.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1335.34 1035.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 517.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 91.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 213.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 67.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 487.11 170.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 181.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 154.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 28.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 68.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 25.33 346.62 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 17.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1335.34 1035.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

AirTerminal:SingleDuct:VAV:Reheat

Design Size Maximum Air Flow Rate [m3/s] Design Size Constant Minimum Air Flow Fraction User-Specified Constant Minimum Air Flow Fraction Design Size Minimum Air Flow Rate [m3/s] Design Size Maximum Flow Fraction during Reheat [] User-Specified Maximum Flow Fraction during Reheat [] Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] Design Size Maximum Reheat Water Flow Rate [m3/s] Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] Design Size Reheat Coil Sizing Inlet Air Temperature [C] Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir]
BASEMENT VAV BOX COMPONENT 2.46 0.611801 0.489000 1.21 1.00 0.500000 0.000623 0.000085 1.21 16.70 0.008000
RETAIL_1_FLR_1 VAV BOX COMPONENT 0.563139 0.090756 0.489000 0.275375 0.489000 0.500000 0.004198 0.000054 0.275375 16.70 0.008000
RETAIL_2_FLR_1 VAV BOX COMPONENT 0.249240 0.237457 0.489000 0.121878 0.633218 0.500000 0.001605 0.000019 0.121878 16.70 0.008000
MECH_FLR_1 VAV BOX COMPONENT 0.227444 0.550259 0.489000 0.111220 1.00 0.500000 0.000692 0.000032 0.130684 16.70 0.008000
STORAGE_FLR_1 VAV BOX COMPONENT 0.110121 0.655703 0.489000 0.053849 1.00 0.500000 0.000581 0.000020 0.082620 16.70 0.008000
LAUNDRY_FLR_1 VAV BOX COMPONENT 3.32 0.071122 0.489000 1.62 0.489000 0.500000 0.021258 0.000109 1.62 16.70 0.008000
CAFE_FLR_1 VAV BOX COMPONENT 2.09 0.068821 0.489000 1.02 0.489000 0.500000 0.005536 0.000151 1.02 16.70 0.008000
LOBBY_FLR_1 VAV BOX COMPONENT 5.44 0.183379 0.489000 2.66 0.489011 0.500000 0.002078 0.000367 2.66 16.70 0.008000
CORRIDOR_FLR_3 VAV BOX COMPONENT 1.74 0.681753 0.489000 0.851330 1.00 0.500000 0.000559 0.000180 0.851330 16.70 0.008000
BANQUET_FLR_6 VAV BOX COMPONENT 2.15 0.117702 0.489000 1.05 0.489000 0.500000 0.003237 0.000142 1.05 16.70 0.008000
DINING_FLR_6 VAV BOX COMPONENT 2.25 0.112402 0.489000 1.10 0.489000 0.500000 0.003390 0.000146 1.10 16.70 0.008000
KITCHEN_FLR_6 VAV BOX COMPONENT 2.37 0.059736 0.489000 1.16 0.489000 0.500000 0.011472 0.000098 1.16 16.70 0.008000
CORRIDOR_FLR_6 VAV BOX COMPONENT 0.863246 0.363788 0.489000 0.422127 0.970103 0.500000 0.001047 0.000120 0.488020 16.70 0.008000
User-Specified values were used. Design Size values were used if no User-Specified values were provided. Design Size values may be derived from alternate User-Specified values.

Coil:Heating:Water

Design Size Rated Capacity [W] Design Size Maximum Water Flow Rate [m3/s] Design Size U-Factor Times Area Value [W/K]
BASEMENT VAV BOX REHEAT COIL 9737.54 0.000085 209.09
RETAIL_1_FLR_1 VAV BOX REHEAT COIL 6225.25 0.000054 157.80
RETAIL_2_FLR_1 VAV BOX REHEAT COIL 2210.42 0.000019 53.04
MECH_FLR_1 VAV BOX REHEAT COIL 3679.96 0.000032 100.43
STORAGE_FLR_1 VAV BOX REHEAT COIL 2326.56 0.000020 63.49
LAUNDRY_FLR_1 VAV BOX REHEAT COIL 12407.85 0.000109 265.24
CAFE_FLR_1 VAV BOX REHEAT COIL 17280.07 0.000151 408.68
LOBBY_FLR_1 VAV BOX REHEAT COIL 41972.45 0.000367 980.02
ROOM_1_FLR_3 FAN COIL HEATING COIL 10951.56 0.000096 312.95
ROOM_2_FLR_3 FAN COIL HEATING COIL 10941.36 0.000096 312.66
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL 61702.12 0.000540 1763.18
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL 61554.79 0.000539 1758.98
ROOM_5_FLR_3 FAN COIL HEATING COIL 10932.85 0.000096 312.41
ROOM_6_FLR_3 FAN COIL HEATING COIL 10922.65 0.000096 312.12
CORRIDOR_FLR_3 VAV BOX REHEAT COIL 20585.68 0.000180 532.45
ROOM_1_FLR_6 FAN COIL HEATING COIL 3345.28 0.000029 95.59
ROOM_2_FLR_6 FAN COIL HEATING COIL 3341.81 0.000029 95.49
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL 15986.68 0.000140 456.81
BANQUET_FLR_6 VAV BOX REHEAT COIL 16205.70 0.000142 376.85
DINING_FLR_6 VAV BOX REHEAT COIL 16655.75 0.000146 386.06
KITCHEN_FLR_6 VAV BOX REHEAT COIL 11196.51 0.000098 244.42
CORRIDOR_FLR_6 VAV BOX REHEAT COIL 13744.05 0.000120 375.10
VAV WITH REHEAT HEATING COIL 495976.60 0.004339 6515.43
FLR_3_DOAS HEATING COIL 42957.20 0.000376 564.31
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:ZoneExhaust

User-Specified Maximum Flow Rate [m3/s]
LOBBY_FLR_1 EXHAUST FAN 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
ROOM_1_FLR_3 DIRECT AIR 0.061735
ROOM_2_FLR_3 DIRECT AIR 0.061728
ROOM_3_MULT19_FLR_3 DIRECT AIR 0.837072
ROOM_4_MULT19_FLR_3 DIRECT AIR 0.837300
ROOM_5_FLR_3 DIRECT AIR 0.061735
ROOM_6_FLR_3 DIRECT AIR 0.061728
ROOM_1_FLR_6 DIRECT AIR 0.015434
ROOM_2_FLR_6 DIRECT AIR 0.015432
ROOM_3_MULT9_FLR_6 DIRECT AIR 0.099154
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

ZoneHVAC:FourPipeFanCoil

Design Size Maximum Supply Air Flow Rate [m3/s] Design Size Maximum Hot Water Flow [m3/s] Design Size Maximum Cold Water Flow [m3/s]
ROOM_1_FLR_3 FAN COIL 1.31 0.000096 0.000507
ROOM_2_FLR_3 FAN COIL 1.17 0.000096 0.000452
ROOM_3_MULT19_FLR_3 FAN COIL 9.62 0.000540 0.003698
ROOM_4_MULT19_FLR_3 FAN COIL 5.78 0.000539 0.002352
ROOM_5_FLR_3 FAN COIL 1.23 0.000096 0.000476
ROOM_6_FLR_3 FAN COIL 1.10 0.000096 0.000428
ROOM_1_FLR_6 FAN COIL 0.340428 0.000029 0.000132
ROOM_2_FLR_6 FAN COIL 0.300281 0.000029 0.000117
ROOM_3_MULT9_FLR_6 FAN COIL 2.02 0.000140 0.000792
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN 1.31
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN 1.17
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN 9.62
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN 5.78
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN 1.23
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN 1.10
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN 0.340428
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN 0.300281
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN 2.02
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:Water

Design Size Design Inlet Air Temperature [C] Design Size Design Inlet Water Temperature [C] Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] Design Size Design Outlet Air Temperature [C] Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] Design Size Design Water Flow Rate [m3/s] Design Size Design Air Flow Rate [m3/s] Design Size Design Coil Load [W]
ROOM_1_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008532 12.80 0.008500 0.000507 1.31  
ROOM_2_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008535 12.80 0.008500 0.000452 1.17  
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008482 12.80 0.008482 0.003698 9.62  
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008712 12.80 0.008500 0.002352 5.78  
ROOM_5_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008534 12.80 0.008500 0.000476 1.23  
ROOM_6_FLR_3 FAN COIL COOLING COIL 21.69 6.70 0.008537 12.80 0.008500 0.000428 1.10  
ROOM_1_FLR_6 FAN COIL COOLING COIL 21.69 6.70 0.008531 12.80 0.008500 0.000132 0.340428  
ROOM_2_FLR_6 FAN COIL COOLING COIL 21.69 6.70 0.008534 12.80 0.008500 0.000117 0.300281  
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL 21.69 6.70 0.008564 12.80 0.008500 0.000792 2.02  
VAV WITH REHEAT COOLING COIL 25.67 6.70 0.008298 10.95 0.008298 0.015062 23.68 421695.42
FLR_3_DOAS COOLING COIL 27.40 6.70 0.007007 11.91 0.007007 0.001369 2.05 38332.30
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
VAV WITH REHEAT 11.91 11.65 23.83 11.65 23.68 23.68 0.300000 0.491999 23.68
FLR_3_DOAS 2.05 2.05 2.05 2.05 2.05 2.05 0.300000 1.00 2.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
VAV WITH REHEAT_OA_CONTROLLER 23.68 11.66
FLR_3_DOAS_OA_CONTROLLER 2.05 2.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

HeatExchanger:AirToAir:SensibleAndLatent

Design Size Nominal Supply Air Flow Rate [m3/s]
VAV WITH REHEAT OA HEAT RECOVERY 11.66
FLR_3_DOAS OA HEAT RECOVERY 2.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:VariableVolume

Design Size Maximum Flow Rate [m3/s]
VAV WITH REHEAT FAN 23.68
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:WaterCoil

Maximum Actuated Flow [m3/s] Controller Convergence Tolerance
VAV WITH REHEAT_COOLC_CONTROLLER 0.015062 0.000032
VAV WITH REHEAT_HEATC_CONTROLLER 0.004339  
FLR_3_DOAS_COOLC_CONTROLLER 0.001369 0.000348
FLR_3_DOAS_HEATC_CONTROLLER 0.000376  
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:ConstantVolume

User-Specified Maximum Flow Rate [m3/s]
FLR_3_DOAS FAN 2.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:VariableSpeed

Design Flow Rate [m3/s] Design Power Consumption [W] Design Minimum Flow Rate [m3/s]
COOLSYS1 PUMP SECONDARY 0.025385 5230.98  
HEATSYS1 PUMP 0.007898 2378.66 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
HEATSYS1 0.007898 0.947813
COOLSYS1 0.025385 3.05
SWHSYS1 0.000375 0.045004
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Boiler:HotWater

Design Size Nominal Capacity [W] User-Specified Nominal Capacity [W] Design Size Design Water Flow Rate [m3/s]
HEATSYS1 BOILER 902840.68 902840.68 0.007898
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
COOLSYS1 PUMP 0.025385 3621.59
SWHSYS1 PUMP 0.000375 47.91
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Chiller:Electric:EIR

Design Size Reference Chilled Water Flow Rate [m3/s] Design Size Reference Capacity [W] User-Specified Reference Capacity [W] Design Size Reference Condenser Fluid Flow Rate [m3/s]
COOLSYS1 CHILLER1 0.025385 710722.48 711369.19 81.10
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SWHSYS1 WATER HEATER 0.000375
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
RETAIL_1_FLR_1_CEILING ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH |
CAFE_FLR_1_CEILING ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH |
LOBBY_FLR_1_CEILING_2 ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
RETAIL_1_FLR_1_WALL_SOUTH RETAIL_1_FLR_1_WALL_SOUTH_WINDOW |
RETAIL_2_FLR_1_WALL_WEST RETAIL_2_FLR_1_WALL_WEST_DOOR |
STORAGE_FLR_1_WALL_NORTH STORAGE_FLR_1_WALL_NORTH_ROLLDOOR |
LAUNDRY_FLR_1_WALL_EAST LAUNDRY_FLR_1_WALL_EAST_DOOR |
CAFE_FLR_1_WALL_EAST CAFE_FLR_1_WALL_EAST_DOOR |
CAFE_FLR_1_WALL_SOUTH CAFE_FLR_1_WALL_SOUTH_WINDOW |
LOBBY_FLR_1_WALL_1_NORTH LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 |
LOBBY_FLR_1_WALL_1_SOUTH LOBBY_FLR_1_WALL_SOUTH_WINDOW |
ROOM_1_FLR_3_WALL_SOUTH ROOM_1_FLR_3_WALL_SOUTH_WINDOW |
ROOM_1_FLR_3_WALL_WEST ROOM_1_FLR_3_WALL_WEST_WINDOW |
ROOM_2_FLR_3_WALL_NORTH ROOM_2_FLR_3_WALL_NORTH_WINDOW |
ROOM_2_FLR_3_WALL_WEST ROOM_2_FLR_3_WALL_WEST_WINDOW |
ROOM_3_MULT19_FLR_3_WALL_SOUTH ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW |
ROOM_4_MULT19_FLR_3_WALL_NORTH ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW |
ROOM_5_FLR_3_WALL_EAST ROOM_5_FLR_3_WALL_EAST_WINDOW |
ROOM_5_FLR_3_WALL_SOUTH ROOM_5_FLR_3_WALL_SOUTH_WINDOW |
ROOM_6_FLR_3_WALL_NORTH ROOM_6_FLR_3_WALL_NORTH_WINDOW |
ROOM_6_FLR_3_WALL_EAST ROOM_6_FLR_3_WALL_EAST_WINDOW |
CORRIDOR_FLR_3_WALL_1_NORTH CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW |
CORRIDOR_FLR_3_WALL_2_NORTH CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW |
CORRIDOR_FLR_3_WALL_1_SOUTH CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW |
CORRIDOR_FLR_3_WALL_2_SOUTH CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW |
ROOM_1_FLR_6_WALL_SOUTH ROOM_1_FLR_6_WALL_SOUTH_WINDOW |
ROOM_1_FLR_6_WALL_WEST ROOM_1_FLR_6_WALL_WEST_WINDOW |
ROOM_2_FLR_6_WALL_NORTH ROOM_2_FLR_6_WALL_NORTH_WINDOW |
ROOM_2_FLR_6_WALL_WEST ROOM_2_FLR_6_WALL_WEST_WINDOW |
ROOM_3_MULT9_FLR_6_WALL_SOUTH ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW |
BANQUET_FLR_6_WALL_NORTH BANQUET_FLR_6_WALL_NORTH_WINDOW |
DINING_FLR_6_WALL_NORTH DINING_FLR_6_WALL_NORTH_WINDOW |
KITCHEN_FLR_6_WALL_NORTH KITCHEN_FLR_6_WALL_NORTH_WINDOW |
KITCHEN_FLR_6_WALL_EAST KITCHEN_FLR_6_WALL_EAST_WINDOW |
KITCHEN_FLR_6_WALL_1_SOUTH KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW |
CORRIDOR_FLR_6_WALL_1_NORTH CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW |
CORRIDOR_FLR_6_WALL_2_NORTH CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW |
CORRIDOR_FLR_6_WALL_2_SOUTH CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Version

Version ID
1 22.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes Yes No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 -3.10 -17.70 -19.30 -17.60 -15.40 -10.30 0.70 10.60 16.00 16.90 14.20 6.70


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 Fairbanks Intl Arpt AK USA TMY3 WMO#=702610 64.82 -147.85 -9.00 133.00 99737 1.1854


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA -1.53 36.20 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 HotelLarge 0.000 City 4.00000E-002 0.20000 FullInteriorAndExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 DOE-2


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 22 235 36


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 BASEMENT 0.0 0.00 0.00 0.00 41.45 11.51 -1.22 1 1 1 0.00 86.56 0.00 22.86 -2.44 0.00 2.44 4826.41 TARP DOE-2 1978.83 0.00 0.00 0.00 13 0 0 Yes
2 RETAIL_1_FLR_1 0.0 0.00 0.00 0.00 5.79 2.90 1.98 1 1 1 0.00 11.58 0.00 5.79 0.00 3.96 3.96 265.76 TARP DOE-2 67.07 68.84 45.58 23.26 6 1 0 Yes
3 RETAIL_2_FLR_1 0.0 0.00 0.00 0.00 5.79 9.14 1.98 1 1 1 0.00 11.58 5.79 12.50 0.00 3.96 3.96 307.76 TARP DOE-2 77.67 26.57 24.62 0.00 6 1 0 Yes
4 MECH_FLR_1 0.0 0.00 0.00 0.00 61.87 17.68 1.98 1 1 1 53.95 69.80 12.50 22.86 0.00 3.96 3.96 650.80 TARP DOE-2 164.24 62.80 62.80 0.00 6 0 0 Yes
5 STORAGE_FLR_1 0.0 0.00 0.00 0.00 74.37 17.68 1.98 1 1 1 69.80 78.94 12.50 22.86 0.00 3.96 3.96 375.47 TARP DOE-2 94.76 36.23 28.80 0.00 6 1 0 Yes
6 LAUNDRY_FLR_1 0.0 0.00 0.00 0.00 84.28 14.33 1.98 1 1 1 81.99 86.56 5.79 22.86 0.00 3.96 3.96 309.22 TARP DOE-2 78.04 85.75 83.80 0.00 6 1 0 Yes
7 CAFE_FLR_1 0.0 0.00 0.00 0.00 70.26 2.90 1.98 1 1 1 53.95 86.56 0.00 5.79 0.00 3.96 3.96 748.35 TARP DOE-2 188.86 152.17 84.72 65.50 7 2 0 Yes
8 LOBBY_FLR_1 0.0 0.00 0.00 0.00 38.29 12.45 1.98 1 1 1 0.00 81.99 0.00 22.86 0.00 3.96 3.96 5183.56 TARP DOE-2 1308.19 434.79 345.80 85.08 18 3 0 Yes
9 ROOM_1_FLR_3 0.0 0.00 0.00 0.00 2.29 10.06 8.53 1 4 1 0.00 4.57 5.79 14.33 7.01 10.06 3.05 118.94 TARP DOE-2 39.02 39.95 26.77 13.18 6 2 0 Yes
10 ROOM_2_FLR_3 0.0 0.00 0.00 0.00 2.29 18.59 8.53 1 4 1 0.00 4.57 14.33 22.86 7.01 10.06 3.05 118.93 TARP DOE-2 39.02 39.95 26.76 13.18 6 2 0 Yes
11 ROOM_3_MULT19_FLR_3 0.0 0.00 0.00 0.00 8.53 9.14 8.53 1 76 1 6.71 10.36 5.79 12.50 7.01 10.06 3.05 74.75 TARP DOE-2 24.52 11.15 7.47 3.68 6 1 0 Yes
12 ROOM_4_MULT19_FLR_3 0.0 0.00 0.00 0.00 12.19 19.51 8.53 1 76 1 10.36 14.02 16.15 22.86 7.01 10.06 3.05 74.77 TARP DOE-2 24.53 11.15 7.47 3.68 6 1 0 Yes
13 ROOM_5_FLR_3 0.0 0.00 0.00 0.00 84.28 10.06 8.53 1 4 1 81.99 86.56 5.79 14.33 7.01 10.06 3.05 118.94 TARP DOE-2 39.02 39.95 26.77 13.18 6 2 0 Yes
14 ROOM_6_FLR_3 0.0 0.00 0.00 0.00 84.28 18.59 8.53 1 4 1 81.99 86.56 14.33 22.86 7.01 10.06 3.05 118.93 TARP DOE-2 39.02 39.95 26.76 13.18 6 2 0 Yes
15 CORRIDOR_FLR_3 0.0 0.00 0.00 0.00 43.28 14.33 8.53 1 4 1 4.57 81.99 5.79 22.86 7.01 10.06 3.05 1186.91 TARP DOE-2 389.40 48.31 32.37 15.94 20 4 0 Yes
16 ROOM_1_FLR_6 0.0 0.00 0.00 0.00 2.29 10.06 17.68 1 1 1 0.00 4.57 5.79 14.33 16.15 19.20 3.05 118.94 TARP DOE-2 39.02 39.95 26.77 13.18 6 2 0 Yes
17 ROOM_2_FLR_6 0.0 0.00 0.00 0.00 2.29 18.59 17.68 1 1 1 0.00 4.57 14.33 22.86 16.15 19.20 3.05 118.93 TARP DOE-2 39.02 39.95 26.76 13.18 6 2 0 Yes
18 ROOM_3_MULT9_FLR_6 0.0 0.00 0.00 0.00 7.93 7.62 17.68 1 9 1 4.57 11.28 5.79 9.45 16.15 19.20 3.05 74.77 TARP DOE-2 24.53 20.44 13.70 6.74 6 1 0 Yes
19 BANQUET_FLR_6 0.0 0.00 0.00 0.00 26.37 17.68 17.68 1 1 1 10.36 42.37 12.50 22.86 16.15 19.20 3.05 1010.89 TARP DOE-2 331.66 97.55 65.36 32.19 6 1 0 Yes
20 DINING_FLR_6 0.0 0.00 0.00 0.00 63.55 17.68 17.68 1 1 1 47.55 79.55 12.50 22.86 16.15 19.20 3.05 1010.89 TARP DOE-2 331.66 97.55 65.36 32.19 6 1 0 Yes
21 KITCHEN_FLR_6 0.0 0.00 0.00 0.00 82.99 14.11 17.68 1 1 1 79.55 86.56 5.79 22.86 16.15 19.20 3.05 314.87 TARP DOE-2 103.30 87.33 60.96 26.37 8 3 0 Yes
22 CORRIDOR_FLR_6 0.0 0.00 0.00 0.00 41.51 13.35 17.68 1 1 1 4.57 81.99 5.79 22.86 16.15 19.20 3.05 1256.16 TARP DOE-2 412.12 85.47 57.27 28.20 15 3 0 Yes


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 BASEMENT 1978.83 106.5 18.581 5.382E-002 9.139 5.380 0.000 0.000 0.000 0.000 14.519 No
2 RETAIL_1_FLR_1 67.07 10.8 6.194 0.161 13.336 10.760 0.000 0.000 0.000 0.000 24.096 No
3 RETAIL_2_FLR_1 77.67 12.5 6.194 0.161 13.336 10.760 0.000 0.000 0.000 0.000 24.096 No
4 MECH_FLR_1 164.24 2.7 61.932 1.615E-002 9.203 5.380 0.000 0.000 0.000 0.000 14.583 No
5 STORAGE_FLR_1 94.76 2.0 46.451 2.153E-002 6.103 2.690 0.000 0.000 0.000 0.000 8.793 No
6 LAUNDRY_FLR_1 78.04 8.4 9.290 0.108 5.813 61.680 535.850 0.000 0.000 0.000 603.343 No
7 CAFE_FLR_1 188.86 142.3 1.327 0.753 10.366 5.380 0.000 0.000 0.000 0.000 15.746 No
8 LOBBY_FLR_1 1308.19 422.4 3.097 0.323 8.719 8.070 0.000 0.000 0.000 0.000 16.789 No
9 ROOM_1_FLR_3 39.02 1.5 26.015 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
10 ROOM_2_FLR_3 39.02 1.5 26.012 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
11 ROOM_3_MULT19_FLR_3 24.52 1.5 16.349 6.116E-002 4.553 10.520 0.000 0.000 0.000 0.000 15.073 No
12 ROOM_4_MULT19_FLR_3 24.53 1.5 16.354 6.115E-002 4.553 10.520 0.000 0.000 0.000 0.000 15.073 No
13 ROOM_5_FLR_3 39.02 1.5 26.015 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
14 ROOM_6_FLR_3 39.02 1.5 26.012 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
15 CORRIDOR_FLR_3 389.40 21.0 18.581 5.382E-002 6.394 0.000 0.000 0.000 0.000 0.000 6.394 No
16 ROOM_1_FLR_6 39.02 1.5 26.015 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
17 ROOM_2_FLR_6 39.02 1.5 26.012 3.844E-002 4.553 6.750 0.000 0.000 0.000 0.000 11.303 No
18 ROOM_3_MULT9_FLR_6 24.53 1.5 16.354 6.115E-002 4.553 10.520 0.000 0.000 0.000 0.000 15.073 No
19 BANQUET_FLR_6 331.66 249.9 1.327 0.753 10.366 67.820 0.000 0.000 0.000 0.000 78.186 No
20 DINING_FLR_6 331.66 249.9 1.327 0.753 10.366 67.820 0.000 0.000 0.000 0.000 78.186 No
21 KITCHEN_FLR_6 103.30 22.2 4.645 0.215 11.722 515.227 2419.260 0.000 0.000 0.000 2946.209 No
22 CORRIDOR_FLR_6 412.12 22.2 18.581 5.382E-002 6.394 0.000 0.000 0.000 0.000 0.000 6.394 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People MRT Calculation Type Work Efficiency Clothing Insulation Calculation Method Clothing Insulation Calculation Method Schedule Clothing Air Velocity Fanger Calculation Pierce Calculation KSU Calculation Cooling Effect Calculation Ankle Draft Calculation
1 BASEMENT PEOPLE BLDG_OCC_SCH BASEMENT 1978.83 106.5 106.5 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 106 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
2 RETAIL_1_FLR_1 PEOPLE BLDG_OCC_SCH RETAIL_1_FLR_1 67.07 10.8 10.8 0.161 6.194 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
3 RETAIL_2_FLR_1 PEOPLE BLDG_OCC_SCH RETAIL_2_FLR_1 77.67 12.5 12.5 0.161 6.194 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 13 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
4 LAUNDRY_FLR_1 PEOPLE BLDG_OCC_SCH LAUNDRY_FLR_1 78.04 8.4 8.4 0.108 9.290 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 8 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
5 CAFE_FLR_1 PEOPLE BLDG_OCC_SCH CAFE_FLR_1 188.86 142.3 142.3 0.753 1.327 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 142 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
6 LOBBY_FLR_1 PEOPLE BLDG_OCC_SCH LOBBY_FLR_1 1308.19 422.4 422.4 0.323 3.097 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 422 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
7 ROOM_1_FLR_3 PEOPLE GUESTROOM_OCC_SCH ROOM_1_FLR_3 39.02 1.5 1.5 3.844E-002 26.015 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
8 ROOM_2_FLR_3 PEOPLE GUESTROOM_OCC_SCH ROOM_2_FLR_3 39.02 1.5 1.5 3.844E-002 26.012 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
9 ROOM_3_MULT19_FLR_3 PEOPLE ALWAYS_OFF ROOM_3_MULT19_FLR_3 24.52 1.5 1.5 6.116E-002 16.349 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 0 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
10 ROOM_4_MULT19_FLR_3 PEOPLE GUESTROOM_OCC_SCH ROOM_4_MULT19_FLR_3 24.53 1.5 1.5 6.115E-002 16.354 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
11 ROOM_5_FLR_3 PEOPLE GUESTROOM_OCC_SCH ROOM_5_FLR_3 39.02 1.5 1.5 3.844E-002 26.015 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
12 ROOM_6_FLR_3 PEOPLE GUESTROOM_OCC_SCH ROOM_6_FLR_3 39.02 1.5 1.5 3.844E-002 26.012 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
13 ROOM_1_FLR_6 PEOPLE GUESTROOM_OCC_SCH ROOM_1_FLR_6 39.02 1.5 1.5 3.844E-002 26.015 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
14 ROOM_2_FLR_6 PEOPLE GUESTROOM_OCC_SCH ROOM_2_FLR_6 39.02 1.5 1.5 3.844E-002 26.012 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
15 ROOM_3_MULT9_FLR_6 PEOPLE GUESTROOM_OCC_SCH ROOM_3_MULT9_FLR_6 24.53 1.5 1.5 6.115E-002 16.354 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
16 BANQUET_FLR_6 PEOPLE BLDG_OCC_SCH BANQUET_FLR_6 331.66 249.9 249.9 0.753 1.327 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 250 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
17 DINING_FLR_6 PEOPLE BLDG_OCC_SCH DINING_FLR_6 331.66 249.9 249.9 0.753 1.327 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 250 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
18 KITCHEN_FLR_6 PEOPLE BLDG_OCC_SCH KITCHEN_FLR_6 103.30 22.2 22.2 0.215 4.645 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 22 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
19 STORAGE_FLR_1 PEOPLE BLDG_OCC_SCH STORAGE_FLR_1 94.76 2.0 2.0 2.153E-002 46.451 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
20 CORRIDOR_FLR_3 PEOPLE BLDG_OCC_SCH CORRIDOR_FLR_3 389.40 21.0 21.0 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 21 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
21 CORRIDOR_FLR_6 PEOPLE BLDG_OCC_SCH CORRIDOR_FLR_6 412.12 22.2 22.2 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 22 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
22 MECH_FLR_1 PEOPLE BLDG_OCC_SCH MECH_FLR_1 164.24 2.7 2.7 1.615E-002 61.932 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 3 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 BASEMENT_LIGHTS LTG_SCH_BASEMENT BASEMENT 1978.83 106.5 18084.325 9.139 169.807 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 18084.325
2 RETAIL_1_FLR_1_LIGHTS LTG_SCH_RETAIL RETAIL_1_FLR_1 67.07 10.8 894.495 13.336 82.602 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 894.495
3 RETAIL_2_FLR_1_LIGHTS LTG_SCH_RETAIL RETAIL_2_FLR_1 77.67 12.5 1035.829 13.336 82.602 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1035.829
4 MECH_FLR_1_LIGHTS LTG_SCH_MECHANIC MECH_FLR_1 164.24 2.7 1511.551 9.203 569.967 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1511.551
5 STORAGE_FLR_1_LIGHTS LTG_SCH_STORAGE STORAGE_FLR_1 94.76 2.0 578.329 6.103 283.494 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 578.329
6 LAUNDRY_FLR_1_LIGHTS LTG_SCH_LAUNDRY LAUNDRY_FLR_1 78.04 8.4 453.605 5.813 54.001 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 453.605
7 CAFE_FLR_1_LIGHTS LTG_SCH_DINING CAFE_FLR_1 188.86 142.3 1957.673 10.366 13.757 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1957.673
8 LOBBY_FLR_1_LIGHTS LTG_SCH_LOBBY LOBBY_FLR_1 1308.19 422.4 11405.759 8.719 27.000 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 11405.759
9 ROOM_1_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_1_FLR_3 39.02 1.5 177.672 4.553 118.448 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.672
10 ROOM_2_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_2_FLR_3 39.02 1.5 177.651 4.553 118.434 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.651
11 ROOM_3_MULT19_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_3_MULT19_FLR_3 24.52 1.5 111.660 4.553 74.440 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 111.660
12 ROOM_4_MULT19_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_4_MULT19_FLR_3 24.53 1.5 111.691 4.553 74.460 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 111.691
13 ROOM_5_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_5_FLR_3 39.02 1.5 177.672 4.553 118.448 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.672
14 ROOM_6_FLR_3_LIGHTS LTG_SCH_GUESTROOM ROOM_6_FLR_3 39.02 1.5 177.651 4.553 118.434 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.651
15 CORRIDOR_FLR_3_LIGHTS LTG_SCH_CORRIDOR CORRIDOR_FLR_3 389.40 21.0 2489.757 6.394 118.803 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 2489.757
16 ROOM_1_FLR_6_LIGHTS LTG_SCH_GUESTROOM ROOM_1_FLR_6 39.02 1.5 177.672 4.553 118.448 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.672
17 ROOM_2_FLR_6_LIGHTS LTG_SCH_GUESTROOM ROOM_2_FLR_6 39.02 1.5 177.651 4.553 118.434 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 177.651
18 ROOM_3_MULT9_FLR_6_LIGHTS LTG_SCH_GUESTROOM ROOM_3_MULT9_FLR_6 24.53 1.5 111.691 4.553 74.460 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 111.691
19 BANQUET_FLR_6_LIGHTS LTG_SCH_DINING BANQUET_FLR_6 331.66 249.9 3437.839 10.366 13.757 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 3437.839
20 DINING_FLR_6_LIGHTS LTG_SCH_DINING DINING_FLR_6 331.66 249.9 3437.839 10.366 13.757 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 3437.839
21 KITCHEN_FLR_6_LIGHTS LTG_SCH_KITCHEN KITCHEN_FLR_6 103.30 22.2 1210.923 11.722 54.453 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1210.923
22 CORRIDOR_FLR_6_LIGHTS LTG_SCH_CORRIDOR CORRIDOR_FLR_6 412.12 22.2 2635.024 6.394 118.802 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 2635.024


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 BASEMENT_MISCPLUG_EQUIP BASEMENT_EQUIP_SCH BASEMENT 1978.83 106.5 10646.106 5.380 99.964 0.000 0.500 0.000 0.500 MiscPlug 0.000 10646.106
2 RETAIL_1_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH RETAIL_1_FLR_1 67.07 10.8 721.688 10.760 66.644 0.000 0.500 0.000 0.500 MiscPlug 0.000 721.688
3 RETAIL_2_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH RETAIL_2_FLR_1 77.67 12.5 835.717 10.760 66.644 0.000 0.500 0.000 0.500 MiscPlug 0.000 835.717
4 MECH_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH MECH_FLR_1 164.24 2.7 883.628 5.380 333.193 0.000 0.500 0.000 0.500 MiscPlug 0.000 883.628
5 STORAGE_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH STORAGE_FLR_1 94.76 2.0 254.902 2.690 124.952 0.000 0.500 0.000 0.500 MiscPlug 0.000 254.902
6 LAUNDRY_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH LAUNDRY_FLR_1 78.04 8.4 4813.474 61.680 573.033 0.000 0.500 0.000 0.500 MiscPlug 0.000 4813.474
7 CAFE_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH CAFE_FLR_1 188.86 142.3 1016.077 5.380 7.140 0.000 0.500 0.000 0.500 MiscPlug 0.000 1016.077
8 LOBBY_FLR_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH LOBBY_FLR_1 1308.19 422.4 10557.062 8.070 24.991 0.000 0.500 0.000 0.500 MiscPlug 0.000 10557.062
9 ROOM_1_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_1_FLR_3 39.02 1.5 263.399 6.750 175.599 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.399
10 ROOM_2_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_2_FLR_3 39.02 1.5 263.368 6.750 175.579 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.368
11 ROOM_3_MULT19_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_3_MULT19_FLR_3 24.52 1.5 257.991 10.520 171.994 0.000 0.500 0.000 0.500 MiscPlug 0.000 257.991
12 ROOM_4_MULT19_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_4_MULT19_FLR_3 24.53 1.5 258.061 10.520 172.041 0.000 0.500 0.000 0.500 MiscPlug 0.000 258.061
13 ROOM_5_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_5_FLR_3 39.02 1.5 263.399 6.750 175.599 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.399
14 ROOM_6_FLR_3_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_6_FLR_3 39.02 1.5 263.368 6.750 175.579 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.368
15 ROOM_1_FLR_6_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_1_FLR_6 39.02 1.5 263.399 6.750 175.599 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.399
16 ROOM_2_FLR_6_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_2_FLR_6 39.02 1.5 263.368 6.750 175.579 0.000 0.500 0.000 0.500 MiscPlug 0.000 263.368
17 ROOM_3_MULT9_FLR_6_PLUGMISC_EQUIP GUESTROOM_EQP_SCH_BASE ROOM_3_MULT9_FLR_6 24.53 1.5 258.061 10.520 172.041 0.000 0.500 0.000 0.500 MiscPlug 0.000 258.061
18 BANQUET_FLR_6_MISCPLUG_EQUIP KITCHEN_ELEC_EQUIP_SCH BANQUET_FLR_6 331.66 249.9 22493.008 67.820 90.009 0.000 0.500 0.000 0.500 Cooking 0.000 6747.903
19 DINING_FLR_6_MISCPLUG_EQUIP KITCHEN_ELEC_EQUIP_SCH DINING_FLR_6 331.66 249.9 22493.008 67.820 90.009 0.000 0.500 0.000 0.500 Cooking 0.000 6747.903
20 KITCHEN_FLR_6_MISCELEC_EQUIP KITCHEN_ELEC_EQUIP_SCH KITCHEN_FLR_6 103.30 22.2 52482.799 508.040 2360.050 0.200 0.500 0.100 0.200 Cooking 0.000 15744.840
21 KITCHEN_FLR_6_REACH-IN-FREEZER ALWAYS_ON KITCHEN_FLR_6 103.30 22.2 457.500 4.429 20.573 0.000 0.250 0.000 0.750 ReachInFreezer 457.500 457.500
22 KITCHEN_FLR_6_REACH-IN-REFRIGERATOR ALWAYS_ON KITCHEN_FLR_6 103.30 22.2 285.000 2.759 12.816 0.000 0.250 0.000 0.750 ReachInRefrigerator 285.000 285.000


GasEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 LAUNDRY_FLR_1_MISCGAS_EQUIP BLDG_EQUIP_SCH LAUNDRY_FLR_1 78.04 8.4 41817.449 535.850 4978.268 0.000 0.500 0.000 0.500 Laundry 0.000 41817.449
2 KITCHEN_FLR_6_MISCGAS_EQUIP KITCHEN_GAS_EQUIP_SCH KITCHEN_FLR_6 103.30 22.2 249920.353 2419.260 11238.437 0.100 0.200 0.700 0.000 Cooking 0.000 74976.106


Construction CTF

Construction Name Index #Layers #CTFs Time Step {hours} ThermalConductance {w/m2-K} OuterThermalAbsorptance InnerThermalAbsorptance OuterSolarAbsorptance InnerSolarAbsorptance Roughness
1 SWINGING DOOR_CON 1 1 1 0.167 2.101 0.900 0.900 0.700 0.700 MediumRough
2 OVERHEAD DOOR_CON 2 1 1 0.167 1.198 0.900 0.900 0.700 0.700 MediumRough
3 INTERIORFURNISHINGS 3 1 9 0.167 0.8000 0.900 0.900 0.700 0.700 MediumSmooth
4 INT_WALL 8 2 4 0.167 6.299 0.900 0.900 0.700 0.700 Smooth
5 NONRES_ROOF 18 3 3 0.167 0.1625 0.900 0.900 0.770 0.700 Rough
6 RES_ROOF 19 3 3 0.167 0.1625 0.900 0.900 0.770 0.700 Rough
7 NONRES_EXT_WALL_GRD 21 3 9 0.167 0.6204 0.900 0.900 0.700 0.700 MediumRough
8 NONRES_EXT_WALL_MID 22 3 9 0.167 0.8896 0.900 0.900 0.700 0.700 MediumRough
9 NONRES_EXT_WALL_TOP 23 3 9 0.167 0.9532 0.900 0.900 0.700 0.700 MediumRough
10 RES_EXT_WALL_MID 25 3 9 0.167 0.8896 0.900 0.900 0.700 0.700 MediumRough
11 RES_EXT_WALL_TOP 26 3 9 0.167 0.9532 0.900 0.900 0.700 0.700 MediumRough
12 NONRES_FLOOR 30 3 7 0.167 0.1901 0.900 0.900 0.700 0.700 MediumSmooth
13 NONRES_FLOOR_CEILING 33 3 7 0.167 0.1901 0.900 0.900 0.700 0.700 VeryRough
14 BASEMENT_FLOOR 36 2 7 0.333 2.705 0.900 0.900 0.700 0.700 MediumRough
15 BASEMENT_WALL_NORTH_CFACTOR 39 2 7 0.167 0.3542 0.000 0.900 0.000 0.700 MediumRough
16 BASEMENT_WALL_EAST_CFACTOR 40 2 7 0.167 0.3542 0.000 0.900 0.000 0.700 MediumRough
17 BASEMENT_WALL_SOUTH_CFACTOR 41 2 7 0.167 0.3542 0.000 0.900 0.000 0.700 MediumRough
18 BASEMENT_WALL_WEST_CFACTOR 42 2 7 0.167 0.3542 0.000 0.900 0.000 0.700 MediumRough


Material CTF Summary

Material Name Thickness {m} Conductivity {w/m-K} Density {kg/m3} Specific Heat {J/kg-K} ThermalResistance {m2-K/w}
1 OPAQUE DOOR PANEL_CON 0.0000 0.000 0.000 0.000 0.4760
2 OVERHEAD DOOR_CON PANEL 0.0000 0.000 0.000 0.000 0.8346
3 STD WOOD 6INCH 0.1500 0.120 540.000 1210.000 1.250
4 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
5 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
6 F13 BUILT-UP ROOFING 0.0095 0.160 1120.000 1460.000 0.5938E-01
7 NONRES_ROOF_INSULATION 0.0000 0.000 0.000 0.000 6.093
8 F08 METAL SURFACE 0.0008 45.280 7824.000 500.000 0.1767E-04
9 F13 BUILT-UP ROOFING 0.0095 0.160 1120.000 1460.000 0.5938E-01
10 RES_ROOF_INSULATION 0.0000 0.000 0.000 0.000 6.093
11 F08 METAL SURFACE 0.0008 45.280 7824.000 500.000 0.1767E-04
12 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
13 NONRES_EXTERIOR_WALL_INSULATION_GRD 0.0000 0.000 0.000 0.000 1.444
14 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
15 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
16 NONRES_EXTERIOR_WALL_INSULATION_MID 0.0000 0.000 0.000 0.000 0.9567
17 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
18 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
19 NONRES_EXTERIOR_WALL_INSULATION_TOP 0.0000 0.000 0.000 0.000 0.8818
20 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
21 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
22 RES_EXTERIOR_WALL_INSULATION_MID 0.0000 0.000 0.000 0.000 0.9567
23 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
24 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
25 RES_EXTERIOR_WALL_INSULATION_TOP 0.0000 0.000 0.000 0.000 0.8818
26 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
27 NONRES_FLOOR_INSULATION 0.0000 0.000 0.000 0.000 5.000
28 100MM NORMALWEIGHT CONCRETE FLOOR 0.1016 2.310 2322.000 832.000 0.4398E-01
29 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
30 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
31 100MM NORMALWEIGHT CONCRETE FLOOR 0.1016 2.310 2322.000 832.000 0.4398E-01
32 NONRES_FLOOR_INSULATION 0.0000 0.000 0.000 0.000 5.000
33 M10 200MM CONCRETE BLOCK BASEMENT WALL 0.2032 1.326 1842.000 912.000 0.1532
34 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
35 ~FC_Insulation_1 0.0000 0.000 0.000 0.000 2.747
36 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
37 ~FC_Insulation_2 0.0000 0.000 0.000 0.000 2.747
38 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
39 ~FC_Insulation_3 0.0000 0.000 0.000 0.000 2.747
40 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
41 ~FC_Insulation_4 0.0000 0.000 0.000 0.000 2.747
42 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01


CTF

Time Outside Cross Inside Flux (except final one)
1 1 0.0000000 0.0000000 -0.0000000 -0.0000000
2 0 2.1009573 2.1009573 2.1009573  
3 1 0.0000000 0.0000000 -0.0000000 -0.0000000
4 0 1.1981135 1.1981135 1.1981135  
5 9 -0.27580628E-02 0.97439125E-12 -0.27580628E-02 0.28516790E-03
6 8 0.73590997E-01 0.21837543E-08 0.73590997E-01 -0.77836043E-02
7 7 -0.82599318 0.23162835E-06 -0.82599318 0.89703933E-01
8 6 5.1113916 0.48671053E-05 5.1113916 -0.57224845
9 5 -19.214933 0.30163627E-04 -19.214933 2.2266322
10 4 45.557404 0.63181060E-04 45.557404 -5.4853312
11 3 -68.275533 0.44785456E-04 -68.275533 8.5710568
12 2 62.555368 0.93952058E-05 62.555368 -8.2111738
13 1 -31.904423 0.39200004E-06 -31.904423 4.3886678
14 0 6.9260389 0.77047546E-09 6.9260389  
15 4 0.68458728E-09 0.26079551E-09 0.68458728E-09 -0.34507121E-18
16 3 -0.72180374E-03 0.24295686E-03 -0.72180374E-03 0.69691454E-09
17 2 0.83054762 0.27682775 0.83054762 -0.35168967E-03
18 1 -12.650482 3.3590720 -12.650482 0.19281313
19 0 16.907513 1.4507143 16.907513  
20 3 -0.63083111E-06 0.74112372E-09 -0.38647046E-05 0.15329585E-16
21 2 0.78415922 0.99752939E-03 1.0633801 -0.74093433E-06
22 1 -22.010056 0.66447931E-01 -6.3131541 0.20386814
23 0 21.355302 0.61958938E-01 5.3791822  
24 3 -0.63083111E-06 0.74112372E-09 -0.38647046E-05 0.15329585E-16
25 2 0.78415922 0.99752939E-03 1.0633801 -0.74093433E-06
26 1 -22.010056 0.66447931E-01 -6.3131541 0.20386814
27 0 21.355302 0.61958938E-01 5.3791822  
28 9 0.63051269E-15 -0.32308218E-15 -0.16410282E-09 -0.99951010E-17
29 8 0.23891583E-07 0.84466640E-13 0.39866495E-03 -0.27165551E-09
30 7 -0.12863314E-01 0.43064229E-08 -0.23980710E-01 0.14626058E-03
31 6 0.42224327 0.14880745E-05 0.48645232 -0.49468897E-02
32 5 -5.3554004 0.55240760E-04 -4.5514481 0.65227767E-01
33 4 33.731862 0.44951640E-03 21.870777 -0.43180224
34 3 -112.77696 0.97509968E-03 -56.474881 1.5375994
35 2 198.66781 0.54620071E-03 78.655647 -2.9251197
36 1 -171.73201 0.58083407E-04 -55.482579 2.7555333
37 0 57.057407 0.32915515E-06 15.521699  
38 9 -0.23907624E-14 0.31597480E-16 -0.15159381E-09 0.44487065E-16
39 8 0.22138174E-07 0.12005614E-12 0.38055753E-03 -0.25171865E-09
40 7 -0.12324050E-01 0.62153905E-08 -0.23204591E-01 0.14012894E-03
41 6 0.40759191 0.21632260E-05 0.47399999 -0.47741848E-02
42 5 -5.2124386 0.80803221E-04 -4.4559231 0.63455088E-01
43 4 33.099615 0.66123170E-03 21.497653 -0.42340758
44 3 -111.43211 0.14415773E-02 -55.737335 1.5181690
45 2 197.33529 0.81112906E-03 77.978757 -2.9039585
46 1 -171.23995 0.86614752E-04 -55.284900 2.7469094
47 0 57.057407 0.49323094E-06 15.553656  
48 9 0.63796015E-17 0.35026513E-16 -0.14861226E-09 0.64921151E-18
49 8 0.21719229E-07 0.12822517E-12 0.37616054E-03 -0.24695511E-09
50 7 -0.12192862E-01 0.66681186E-08 -0.23015708E-01 0.13863728E-03
51 6 0.40402730 0.23249961E-05 0.47096453 -0.47321665E-02
52 5 -5.1776524 0.86981116E-04 -4.4326110 0.63023755E-01
53 4 32.945748 0.71278800E-03 21.406536 -0.42136466
54 3 -111.10474 0.15559249E-02 -55.557197 1.5134395
55 2 197.01084 0.87644643E-03 77.813538 -2.8988062
56 1 -171.12011 0.93686201E-04 -55.236846 2.7448090
57 0 57.057407 0.53410260E-06 15.561584  
58 9 -0.23907624E-14 0.31597480E-16 -0.15159381E-09 0.44487065E-16
59 8 0.22138174E-07 0.12005614E-12 0.38055753E-03 -0.25171865E-09
60 7 -0.12324050E-01 0.62153905E-08 -0.23204591E-01 0.14012894E-03
61 6 0.40759191 0.21632260E-05 0.47399999 -0.47741848E-02
62 5 -5.2124386 0.80803221E-04 -4.4559231 0.63455088E-01
63 4 33.099615 0.66123170E-03 21.497653 -0.42340758
64 3 -111.43211 0.14415773E-02 -55.737335 1.5181690
65 2 197.33529 0.81112906E-03 77.978757 -2.9039585
66 1 -171.23995 0.86614752E-04 -55.284900 2.7469094
67 0 57.057407 0.49323094E-06 15.553656  
68 9 0.63796015E-17 0.35026513E-16 -0.14861226E-09 0.64921151E-18
69 8 0.21719229E-07 0.12822517E-12 0.37616054E-03 -0.24695511E-09
70 7 -0.12192862E-01 0.66681186E-08 -0.23015708E-01 0.13863728E-03
71 6 0.40402730 0.23249961E-05 0.47096453 -0.47321665E-02
72 5 -5.1776524 0.86981116E-04 -4.4326110 0.63023755E-01
73 4 32.945748 0.71278800E-03 21.406536 -0.42136466
74 3 -111.10474 0.15559249E-02 -55.557197 1.5134395
75 2 197.01084 0.87644643E-03 77.813538 -2.8988062
76 1 -171.12011 0.93686201E-04 -55.236846 2.7448090
77 0 57.057407 0.53410260E-06 15.561584  
78 7 -0.16359629E-14 -0.14530353E-16 -0.22331004E-13 0.54056000E-15
79 6 0.18262352E-10 0.22801053E-11 0.52333849E-09 -0.18642118E-10
80 5 -0.59540244E-07 0.11129510E-07 -0.21928235E-05 0.17164558E-06
81 4 0.60861605E-04 0.41961443E-05 0.17683552E-02 -0.28248824E-03
82 3 -0.87523238E-02 0.14809838E-03 -0.21562890 0.43346081E-01
83 2 0.12409989 0.64146884E-03 2.9009744 -0.61915653
84 1 -0.31397648 0.40472017E-03 -7.1381115 1.5697592
85 0 0.19977219 0.56546383E-05 4.4522022  
86 7 -0.22331004E-13 -0.14530353E-16 -0.16359629E-14 0.54056000E-15
87 6 0.52333849E-09 0.22801053E-11 0.18262352E-10 -0.18642118E-10
88 5 -0.21928235E-05 0.11129510E-07 -0.59540244E-07 0.17164558E-06
89 4 0.17683552E-02 0.41961443E-05 0.60861605E-04 -0.28248824E-03
90 3 -0.21562890 0.14809838E-03 -0.87523238E-02 0.43346081E-01
91 2 2.9009744 0.64146884E-03 0.12409989 -0.61915653
92 1 -7.1381115 0.40472017E-03 -0.31397648 1.5697592
93 0 4.4522022 0.56546383E-05 0.19977219  
94 7 -0.52459208E-15 -0.63961428E-15 -0.12292524E-09 -0.35846135E-17
95 6 0.39860198E-02 0.96339020E-07 0.40499006E-03 -0.70890431E-04
96 5 -0.20832379 0.49172556E-04 -0.20585669E-01 0.38489246E-02
97 4 3.5198270 0.18993977E-02 0.34924834 -0.69168259E-01
98 3 -23.366787 0.13311857E-01 -2.4329538 0.50524779
99 2 64.890127 0.19943872E-01 7.3672511 -1.5911358
100 1 -76.040094 0.56792084E-02 -9.5568013 2.1361271
101 0 31.242244 0.96490710E-04 4.3344156  
102 7 -0.11729247E-08 -0.12287178E-15 0.68000855E-14 -0.85819789E-16
103 6 0.99010087E-05 0.68275672E-08 0.31776201E-02 -0.26656541E-04
104 5 -0.71743827E-03 0.40498262E-05 -0.22302824 0.19500041E-02
105 4 0.16534150E-01 0.18445051E-03 4.8179460 -0.45153479E-01
106 3 -0.14527752 0.14677644E-02 -37.955880 0.39792938
107 2 0.51595076 0.24428280E-02 116.35639 -1.4162330
108 1 -0.74475336 0.74501918E-03 -143.83221 2.0478056
109 0 0.36311555 0.17917760E-04 60.838472  
110 7 -0.11729247E-08 -0.12287178E-15 0.68000855E-14 -0.85819789E-16
111 6 0.99010087E-05 0.68275672E-08 0.31776201E-02 -0.26656541E-04
112 5 -0.71743827E-03 0.40498262E-05 -0.22302824 0.19500041E-02
113 4 0.16534150E-01 0.18445051E-03 4.8179460 -0.45153479E-01
114 3 -0.14527752 0.14677644E-02 -37.955880 0.39792938
115 2 0.51595076 0.24428280E-02 116.35639 -1.4162330
116 1 -0.74475336 0.74501918E-03 -143.83221 2.0478056
117 0 0.36311555 0.17917760E-04 60.838472  
118 7 -0.11729247E-08 -0.12287178E-15 0.68000855E-14 -0.85819789E-16
119 6 0.99010087E-05 0.68275672E-08 0.31776201E-02 -0.26656541E-04
120 5 -0.71743827E-03 0.40498262E-05 -0.22302824 0.19500041E-02
121 4 0.16534150E-01 0.18445051E-03 4.8179460 -0.45153479E-01
122 3 -0.14527752 0.14677644E-02 -37.955880 0.39792938
123 2 0.51595076 0.24428280E-02 116.35639 -1.4162330
124 1 -0.74475336 0.74501918E-03 -143.83221 2.0478056
125 0 0.36311555 0.17917760E-04 60.838472  
126 7 -0.11729247E-08 -0.12287178E-15 0.68000855E-14 -0.85819789E-16
127 6 0.99010087E-05 0.68275672E-08 0.31776201E-02 -0.26656541E-04
128 5 -0.71743827E-03 0.40498262E-05 -0.22302824 0.19500041E-02
129 4 0.16534150E-01 0.18445051E-03 4.8179460 -0.45153479E-01
130 3 -0.14527752 0.14677644E-02 -37.955880 0.39792938
131 2 0.51595076 0.24428280E-02 116.35639 -1.4162330
132 1 -0.74475336 0.74501918E-03 -143.83221 2.0478056
133 0 0.36311555 0.17917760E-04 60.838472  


WindowConstruction

Construction Name Index #Layers Roughness Conductance {W/m2-K} Conductance (Before Adjusted) {W/m2-K} Convection Coefficient Adjustment Ratio SHGC Solar Transmittance at Normal Incidence Visible Transmittance at Normal Incidence
1 NONRESWINDOW_U_0.2964_SHGC_0.45 37 1 VerySmooth 1.683 1.683 1.000 0.451    
2 RESWINDOW_U_0.2964_SHGC_0.45 38 1 VerySmooth 1.683 1.683 1.000 0.451    


WindowMaterial:Glazing

Material Name Optical Data Type Spectral Data Set Name Thickness {m} Solar Transmittance Front Solar Reflectance Back Solar Reflectance Visible Transmittance Front Visible Reflectance Back Visible Reflectance Infrared Transmittance Front Thermal Emissivity Back Thermal Emissivity Conductivity {W/m-K} Dirt Factor Solar Diffusing
1 GLAZING LAYER SpectralAverage   4.21322E-002 0.36619 0.44048 0.44048 0.45000 0.13324 0.16828 0.00000 0.84000 0.84000 0.10036 1.00000 No
2 RESIDENTIAL WINDOW GLAZING LAYER SpectralAverage   4.21322E-002 0.36619 0.44048 0.44048 0.45000 0.13324 0.16828 0.00000 0.84000 0.84000 0.10036 1.00000 No


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 7 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Enclosure/Window Adjacency Daylighting Counts

Enclosure Name Number of Exterior Windows Number of Exterior Windows in Adjacent Enclosures
1 CAFE_FLR_1 1 0
2 LOBBY_FLR_1 1 0
3 BANQUET_FLR_6 1 0
4 DINING_FLR_6 1 0


Enclosure/Window Adjacency Daylighting Matrix

Enclosure Name Number of Adjacent Enclosures with Windows Adjacent Enclosure Names - 1st 100 (max)
1 CAFE_FLR_1 0  
2 LOBBY_FLR_1 0  
3 BANQUET_FLR_6 0  
4 DINING_FLR_6 0  


#Refrigeration Compressor Racks

Number of Refrigeration Compressor Racks
1 2


Refrigeration Compressor Rack

Compressor Rack Name # Refrigerated Cases Connected # WalkIn Coolers Connected Heat Rejection Location Condenser Type COP
1 RACK1 1 0 Zone Air-Cooled 1.500
2 RACK2 1 0 Zone Air-Cooled 3.000


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWH BOOSTER E WATER HEATER 2.2712E-002 8000.0 1.240 1.1473
2 WaterHeater:Mixed SWH LAUNDRY G WATER HEATER 1.1356 163316.0 0.576 0.5074
3 WaterHeater:Mixed SWHSYS1 WATER HEATER 2.2712 175842.6 0.263 2.9576E-002


Surface Convection Parameters

Surface Name Outside Model Assignment Outside Area [m2] Outside Perimeter [m] Outside Height [m] Inside Model Assignment Inside Height [m] Inside Perimeter Envelope [m] Inside Hydraulic Diameter [m] Window Wall Ratio Window Location Near Radiant {Yes/No} Has Active HVAC {Yes/No}
1 BASEMENT_WALL_NORTH 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
2 BASEMENT_WALL_EAST 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
3 BASEMENT_WALL_SOUTH 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
4 BASEMENT_WALL_WEST 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
5 BASEMENT_FLOOR 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
6 BASEMENT_CEILING_1 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
7 BASEMENT_CEILING_2 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
8 BASEMENT_CEILING_3 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
9 BASEMENT_CEILING_4 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
10 BASEMENT_CEILING_5 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
11 BASEMENT_CEILING_6 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
12 BASEMENT_CEILING_7 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
13 BASEMENT_CEILING_8 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
14 BASEMENT_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.44 0.00 36.17 -999.00 0 No No
15 RETAIL_1_FLR_1_WALL_SOUTH 0 506.51 211.91 19.20 0 3.96 17.37 7.72 0.34 4 No No
16 RETAIL_1_FLR_1_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.96 17.37 7.72 0.34 1 No No
17 RETAIL_1_FLR_1_WALL_WEST 0 194.63 84.12 19.20 0 3.96 17.37 7.72 0.34 3 No No
18 RETAIL_1_FLR_1_WALL_NORTH 0 0.00 0.00 0.00 0 3.96 17.37 7.72 0.34 0 No No
19 RETAIL_1_FLR_1_WALL_EAST 0 0.00 0.00 0.00 0 3.96 17.37 7.72 0.34 0 No No
20 RETAIL_1_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 17.37 7.72 0.34 0 No No
21 RETAIL_1_FLR_1_CEILING 0 1782.60 293.11 15.24 0 3.96 17.37 7.72 0.34 0 No No
22 RETAIL_1_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 17.37 7.72 0.34 0 No No
23 RETAIL_2_FLR_1_WALL_WEST 0 194.63 84.12 19.20 0 3.96 6.71 8.49 0.00 0 No No
24 RETAIL_2_FLR_1_WALL_WEST_DOOR 0 194.63 84.12 19.20 0 3.96 6.71 8.49 0.00 0 No No
25 RETAIL_2_FLR_1_WALL_SOUTH 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
26 RETAIL_2_FLR_1_WALL_NORTH 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
27 RETAIL_2_FLR_1_WALL_EAST 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
28 RETAIL_2_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
29 RETAIL_2_FLR_1_CEILING 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
30 RETAIL_2_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 6.71 8.49 0.00 0 No No
31 MECH_FLR_1_WALL_NORTH 0 670.01 217.46 19.20 0 3.96 15.85 12.53 0.00 0 No No
32 MECH_FLR_1_WALL_EAST 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
33 MECH_FLR_1_WALL_SOUTH 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
34 MECH_FLR_1_WALL_WEST 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
35 MECH_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
36 MECH_FLR_1_CEILING 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
37 MECH_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 15.85 12.53 0.00 0 No No
38 STORAGE_FLR_1_WALL_NORTH 0 670.01 217.46 19.20 0 3.96 9.14 9.72 0.00 0 No No
39 STORAGE_FLR_1_WALL_NORTH_ROLLDOOR 0 670.01 217.46 19.20 0 3.96 9.14 9.72 0.00 0 No No
40 STORAGE_FLR_1_WALL_EAST 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
41 STORAGE_FLR_1_WALL_SOUTH 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
42 STORAGE_FLR_1_WALL_WEST 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
43 STORAGE_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
44 STORAGE_FLR_1_CEILING 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
45 STORAGE_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 9.14 9.72 0.00 0 No No
46 LAUNDRY_FLR_1_WALL_NORTH 0 670.01 217.46 19.20 0 3.96 21.64 7.21 0.00 0 No No
47 LAUNDRY_FLR_1_WALL_EAST 0 194.63 217.46 19.20 0 3.96 21.64 7.21 0.00 0 No No
48 LAUNDRY_FLR_1_WALL_EAST_DOOR 0 194.63 217.46 19.20 0 3.96 21.64 7.21 0.00 0 No No
49 LAUNDRY_FLR_1_WALL_SOUTH 0 0.00 0.00 0.00 0 3.96 21.64 7.21 0.00 0 No No
50 LAUNDRY_FLR_1_WALL_WEST 0 0.00 0.00 0.00 0 3.96 21.64 7.21 0.00 0 No No
51 LAUNDRY_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 21.64 7.21 0.00 0 No No
52 LAUNDRY_FLR_1_CEILING 0 0.00 0.00 0.00 0 3.96 21.64 7.21 0.00 0 No No
53 LAUNDRY_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 21.64 7.21 0.00 0 No No
54 CAFE_FLR_1_WALL_EAST 0 194.63 217.46 19.20 0 3.96 38.40 9.84 0.43 3 No No
55 CAFE_FLR_1_WALL_EAST_DOOR 0 194.63 217.46 19.20 0 3.96 38.40 9.84 0.43 0 No No
56 CAFE_FLR_1_WALL_SOUTH 0 506.51 211.91 19.20 0 3.96 38.40 9.84 0.43 4 No No
57 CAFE_FLR_1_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.96 38.40 9.84 0.43 1 No No
58 CAFE_FLR_1_WALL_1_NORTH 0 0.00 0.00 0.00 0 3.96 38.40 9.84 0.43 0 No No
59 CAFE_FLR_1_WALL_2_NORTH 0 0.00 0.00 0.00 0 3.96 38.40 9.84 0.43 0 No No
60 CAFE_FLR_1_WALL_WEST 0 0.00 0.00 0.00 0 3.96 38.40 9.84 0.43 0 No No
61 CAFE_FLR_1_FLOOR 0 0.00 0.00 0.00 0 3.96 38.40 9.84 0.43 0 No No
62 CAFE_FLR_1_CEILING 0 1782.60 293.11 15.24 0 3.96 38.40 9.84 0.43 0 No No
63 CAFE_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 38.40 9.84 0.43 0 No No
64 LOBBY_FLR_1_WALL_1_NORTH 0 670.01 217.46 19.20 0 3.96 109.73 24.95 0.20 3 No No
65 LOBBY_FLR_1_WALL_1_NORTH_DOOR1 0 670.01 217.46 19.20 0 3.96 109.73 24.95 0.20 0 No No
66 LOBBY_FLR_1_WALL_1_NORTH_DOOR2 0 670.01 217.46 19.20 0 3.96 109.73 24.95 0.20 0 No No
67 LOBBY_FLR_1_WALL_2_NORTH 0 670.01 217.46 19.20 0 3.96 109.73 24.95 0.20 4 No No
68 LOBBY_FLR_1_WALL_1_SOUTH 0 506.51 211.91 19.20 0 3.96 109.73 24.95 0.20 4 No No
69 LOBBY_FLR_1_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.96 109.73 24.95 0.20 1 No No
70 LOBBY_FLR_1_WALL_1_WEST 0 194.63 84.12 19.20 0 3.96 109.73 24.95 0.20 3 No No
71 LOBBY_FLR_1_WALL_2_SOUTH 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
72 LOBBY_FLR_1_WALL_3_SOUTH 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
73 LOBBY_FLR_1_WALL_2_WEST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
74 LOBBY_FLR_1_WALL_3_WEST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
75 LOBBY_FLR_1_WALL_4_WEST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
76 LOBBY_FLR_1_WALL_3_NORTH 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
77 LOBBY_FLR_1_WALL_4_NORTH 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
78 LOBBY_FLR_1_WALL_1_EAST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
79 LOBBY_FLR_1_WALL_2_EAST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
80 LOBBY_FLR_1_WALL_3_EAST 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
81 LOBBY_FLR_1_FLOOR_1 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
82 LOBBY_FLR_1_FLOOR_2 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
83 LOBBY_FLR_1_CEILING_1 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
84 LOBBY_FLR_1_CEILING_2 0 1782.60 293.11 15.24 0 3.96 109.73 24.95 0.20 0 No No
85 LOBBY_FLR_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.96 109.73 24.95 0.20 0 No No
86 ROOM_1_FLR_3_WALL_SOUTH 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 3 No No
87 ROOM_1_FLR_3_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 2 No No
88 ROOM_1_FLR_3_WALL_WEST 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 3 No No
89 ROOM_1_FLR_3_WALL_WEST_WINDOW 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 2 No No
90 ROOM_1_FLR_3_WALL_NORTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
91 ROOM_1_FLR_3_WALL_EAST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
92 ROOM_1_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
93 ROOM_1_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
94 ROOM_1_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
95 ROOM_2_FLR_3_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 3 No No
96 ROOM_2_FLR_3_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 2 No No
97 ROOM_2_FLR_3_WALL_WEST 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 3 No No
98 ROOM_2_FLR_3_WALL_WEST_WINDOW 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 2 No No
99 ROOM_2_FLR_3_WALL_EAST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
100 ROOM_2_FLR_3_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
101 ROOM_2_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
102 ROOM_2_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
103 ROOM_2_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
104 ROOM_3_MULT19_FLR_3_WALL_SOUTH 0 506.51 211.91 19.20 0 3.05 3.66 4.73 0.33 3 No No
105 ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 3.66 4.73 0.33 2 No No
106 ROOM_3_MULT19_FLR_3_WALL_NORTH 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
107 ROOM_3_MULT19_FLR_3_WALL_EAST 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
108 ROOM_3_MULT19_FLR_3_WALL_WEST 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
109 ROOM_3_MULT19_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
110 ROOM_3_MULT19_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
111 ROOM_3_MULT19_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
112 ROOM_4_MULT19_FLR_3_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 3.66 4.73 0.33 3 No No
113 ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 3.66 4.73 0.33 2 No No
114 ROOM_4_MULT19_FLR_3_WALL_EAST 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
115 ROOM_4_MULT19_FLR_3_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
116 ROOM_4_MULT19_FLR_3_WALL_WEST 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
117 ROOM_4_MULT19_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
118 ROOM_4_MULT19_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
119 ROOM_4_MULT19_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 3.66 4.73 0.33 0 No No
120 ROOM_5_FLR_3_WALL_EAST 0 194.63 217.46 19.20 0 3.05 13.11 5.95 0.33 3 No No
121 ROOM_5_FLR_3_WALL_EAST_WINDOW 0 194.63 217.46 19.20 0 3.05 13.11 5.95 0.33 2 No No
122 ROOM_5_FLR_3_WALL_SOUTH 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 3 No No
123 ROOM_5_FLR_3_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 2 No No
124 ROOM_5_FLR_3_WALL_NORTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
125 ROOM_5_FLR_3_WALL_WEST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
126 ROOM_5_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
127 ROOM_5_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
128 ROOM_5_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
129 ROOM_6_FLR_3_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 3 No No
130 ROOM_6_FLR_3_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 2 No No
131 ROOM_6_FLR_3_WALL_EAST 0 194.63 217.46 19.20 0 3.05 13.11 5.95 0.33 3 No No
132 ROOM_6_FLR_3_WALL_EAST_WINDOW 0 194.63 217.46 19.20 0 3.05 13.11 5.95 0.33 2 No No
133 ROOM_6_FLR_3_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
134 ROOM_6_FLR_3_WALL_WEST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
135 ROOM_6_FLR_3_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
136 ROOM_6_FLR_3_CEILING 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
137 ROOM_6_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
138 CORRIDOR_FLR_3_WALL_1_NORTH 0 670.01 217.46 19.20 0 3.05 15.85 8.24 0.33 3 No No
139 CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 15.85 8.24 0.33 2 No No
140 CORRIDOR_FLR_3_WALL_2_NORTH 0 670.01 217.46 19.20 0 3.05 15.85 8.24 0.33 3 No No
141 CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 15.85 8.24 0.33 2 No No
142 CORRIDOR_FLR_3_WALL_1_SOUTH 0 506.51 211.91 19.20 0 3.05 15.85 8.24 0.33 3 No No
143 CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 15.85 8.24 0.33 2 No No
144 CORRIDOR_FLR_3_WALL_2_SOUTH 0 506.51 211.91 19.20 0 3.05 15.85 8.24 0.33 3 No No
145 CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 15.85 8.24 0.33 2 No No
146 CORRIDOR_FLR_3_WALL_3_NORTH 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
147 CORRIDOR_FLR_3_WALL_1_EAST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
148 CORRIDOR_FLR_3_WALL_2_EAST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
149 CORRIDOR_FLR_3_WALL_3_EAST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
150 CORRIDOR_FLR_3_WALL_4_EAST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
151 CORRIDOR_FLR_3_WALL_3_SOUTH 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
152 CORRIDOR_FLR_3_WALL_1_WEST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
153 CORRIDOR_FLR_3_WALL_2_WEST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
154 CORRIDOR_FLR_3_WALL_3_WEST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
155 CORRIDOR_FLR_3_WALL_4_WEST 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
156 CORRIDOR_FLR_3_FLOOR_1 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
157 CORRIDOR_FLR_3_FLOOR_2 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
158 CORRIDOR_FLR_3_FLOOR_3 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
159 CORRIDOR_FLR_3_CEILING_1 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
160 CORRIDOR_FLR_3_CEILING_2 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
161 CORRIDOR_FLR_3_CEILING_3 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
162 CORRIDOR_FLR_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 15.85 8.24 0.33 0 No No
163 ROOM_1_FLR_6_WALL_SOUTH 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 3 No No
164 ROOM_1_FLR_6_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 13.11 5.95 0.33 2 No No
165 ROOM_1_FLR_6_WALL_WEST 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 3 No No
166 ROOM_1_FLR_6_WALL_WEST_WINDOW 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 2 No No
167 ROOM_1_FLR_6_WALL_NORTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
168 ROOM_1_FLR_6_WALL_EAST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
169 ROOM_1_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
170 ROOM_1_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 13.11 5.95 0.33 0 No No
171 ROOM_1_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
172 ROOM_2_FLR_6_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 3 No No
173 ROOM_2_FLR_6_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 13.11 5.95 0.33 2 No No
174 ROOM_2_FLR_6_WALL_WEST 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 3 No No
175 ROOM_2_FLR_6_WALL_WEST_WINDOW 0 194.63 84.12 19.20 0 3.05 13.11 5.95 0.33 2 No No
176 ROOM_2_FLR_6_WALL_EAST 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
177 ROOM_2_FLR_6_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
178 ROOM_2_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
179 ROOM_2_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 13.11 5.95 0.33 0 No No
180 ROOM_2_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 13.11 5.95 0.33 0 No No
181 ROOM_3_MULT9_FLR_6_WALL_SOUTH 0 506.51 211.91 19.20 0 3.05 6.71 4.73 0.33 3 No No
182 ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 6.71 4.73 0.33 2 No No
183 ROOM_3_MULT9_FLR_6_WALL_NORTH 0 0.00 0.00 0.00 0 3.05 6.71 4.73 0.33 0 No No
184 ROOM_3_MULT9_FLR_6_WALL_EAST 0 0.00 0.00 0.00 0 3.05 6.71 4.73 0.33 0 No No
185 ROOM_3_MULT9_FLR_6_WALL_WEST 0 0.00 0.00 0.00 0 3.05 6.71 4.73 0.33 0 No No
186 ROOM_3_MULT9_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 6.71 4.73 0.33 0 No No
187 ROOM_3_MULT9_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 6.71 4.73 0.33 0 No No
188 ROOM_3_MULT9_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 6.71 4.73 0.33 0 No No
189 BANQUET_FLR_6_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 32.00 15.66 0.33 3 No No
190 BANQUET_FLR_6_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 32.00 15.66 0.33 2 No No
191 BANQUET_FLR_6_WALL_EAST 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
192 BANQUET_FLR_6_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
193 BANQUET_FLR_6_WALL_WEST 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
194 BANQUET_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
195 BANQUET_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 32.00 15.66 0.33 0 No No
196 BANQUET_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
197 DINING_FLR_6_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 32.00 15.66 0.33 3 No No
198 DINING_FLR_6_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 32.00 15.66 0.33 2 No No
199 DINING_FLR_6_WALL_EAST 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
200 DINING_FLR_6_WALL_SOUTH 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
201 DINING_FLR_6_WALL_WEST 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
202 DINING_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
203 DINING_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 32.00 15.66 0.33 0 No No
204 DINING_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 32.00 15.66 0.33 0 No No
205 KITCHEN_FLR_6_WALL_NORTH 0 670.01 217.46 19.20 0 3.05 28.65 8.58 0.30 3 No No
206 KITCHEN_FLR_6_WALL_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 28.65 8.58 0.30 2 No No
207 KITCHEN_FLR_6_WALL_EAST 0 194.63 217.46 19.20 0 3.05 28.65 8.58 0.30 3 No No
208 KITCHEN_FLR_6_WALL_EAST_WINDOW 0 194.63 217.46 19.20 0 3.05 28.65 8.58 0.30 2 No No
209 KITCHEN_FLR_6_WALL_1_SOUTH 0 506.51 211.91 19.20 0 3.05 28.65 8.58 0.30 3 No No
210 KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 28.65 8.58 0.30 2 No No
211 KITCHEN_FLR_6_WALL_2_SOUTH 0 0.00 0.00 0.00 0 3.05 28.65 8.58 0.30 0 No No
212 KITCHEN_FLR_6_WALL_1_WEST 0 0.00 0.00 0.00 0 3.05 28.65 8.58 0.30 0 No No
213 KITCHEN_FLR_6_WALL_2_WEST 0 0.00 0.00 0.00 0 3.05 28.65 8.58 0.30 0 No No
214 KITCHEN_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 28.65 8.58 0.30 0 No No
215 KITCHEN_FLR_6_CEILING 0 1782.60 293.11 15.24 0 3.05 28.65 8.58 0.30 0 No No
216 KITCHEN_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 28.65 8.58 0.30 0 No No
217 CORRIDOR_FLR_6_WALL_1_NORTH 0 670.01 217.46 19.20 0 3.05 28.04 8.72 0.33 3 No No
218 CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 28.04 8.72 0.33 2 No No
219 CORRIDOR_FLR_6_WALL_2_NORTH 0 670.01 217.46 19.20 0 3.05 28.04 8.72 0.33 3 No No
220 CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW 0 670.01 217.46 19.20 0 3.05 28.04 8.72 0.33 2 No No
221 CORRIDOR_FLR_6_WALL_2_SOUTH 0 506.51 211.91 19.20 0 3.05 28.04 8.72 0.33 3 No No
222 CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW 0 506.51 211.91 19.20 0 3.05 28.04 8.72 0.33 2 No No
223 CORRIDOR_FLR_6_WALL_3_NORTH 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
224 CORRIDOR_FLR_6_WALL_4_NORTH 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
225 CORRIDOR_FLR_6_WALL_1_SOUTH 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
226 CORRIDOR_FLR_6_WALL_1_WEST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
227 CORRIDOR_FLR_6_WALL_2_WEST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
228 CORRIDOR_FLR_6_WALL_3_WEST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
229 CORRIDOR_FLR_6_WALL_1_EAST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
230 CORRIDOR_FLR_6_WALL_2_EAST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
231 CORRIDOR_FLR_6_WALL_3_EAST 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
232 CORRIDOR_FLR_6_FLOOR 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No
233 CORRIDOR_FLR_6_CEILING_1 0 1782.60 293.11 15.24 0 3.05 28.04 8.72 0.33 0 No No
234 CORRIDOR_FLR_6_CEILING_2 0 1782.60 293.11 15.24 0 3.05 28.04 8.72 0.33 0 No No
235 CORRIDOR_FLR_6_INTERNALMASS_1 0 0.00 0.00 0.00 0 3.05 28.04 8.72 0.33 0 No No


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 RETAIL_1_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH RETAIL_1_FLR_1 67.07 10.8 3.921E-002 5.846E-004 2.885E-004 0.531 1.000 0.000 0.000 0.000
2 RETAIL_2_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH RETAIL_2_FLR_1 77.67 12.5 1.513E-002 1.949E-004 5.306E-004 0.177 1.000 0.000 0.000 0.000
3 MECH_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH MECH_FLR_1 164.24 2.7 3.577E-002 2.178E-004 5.696E-004 0.198 1.000 0.000 0.000 0.000
4 STORAGE_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH STORAGE_FLR_1 94.76 2.0 2.064E-002 2.178E-004 4.726E-004 0.198 1.000 0.000 0.000 0.000
5 LAUNDRY_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH LAUNDRY_FLR_1 78.04 8.4 4.884E-002 6.258E-004 5.569E-004 0.569 1.000 0.000 0.000 0.000
6 CAFE_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH CAFE_FLR_1 188.86 142.3 8.667E-002 4.589E-004 2.527E-004 0.417 1.000 0.000 0.000 0.000
7 LOBBY_FLR_1_INFILTRATION INFIL_QUARTER_ON_SCH LOBBY_FLR_1 1308.19 422.4 0.248 1.893E-004 3.620E-004 0.172 1.000 0.000 0.000 0.000
8 ROOM_1_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_1_FLR_3 39.02 1.5 2.275E-002 5.831E-004 5.696E-004 0.689 1.000 0.000 0.000 0.000
9 ROOM_2_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_2_FLR_3 39.02 1.5 2.275E-002 5.831E-004 5.696E-004 0.689 1.000 0.000 0.000 0.000
10 ROOM_3_MULT19_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_3_MULT19_FLR_3 24.52 1.5 6.349E-003 2.589E-004 5.696E-004 0.306 1.000 0.000 0.000 0.000
11 ROOM_4_MULT19_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_4_MULT19_FLR_3 24.53 1.5 6.350E-003 2.589E-004 5.696E-004 0.306 1.000 0.000 0.000 0.000
12 ROOM_5_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_5_FLR_3 39.02 1.5 2.275E-002 5.831E-004 5.696E-004 0.689 1.000 0.000 0.000 0.000
13 ROOM_6_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_6_FLR_3 39.02 1.5 2.275E-002 5.831E-004 5.696E-004 0.689 1.000 0.000 0.000 0.000
14 CORRIDOR_FLR_3_INFILTRATION INFIL_QUARTER_ON_SCH CORRIDOR_FLR_3 389.40 21.0 2.751E-002 7.066E-005 5.696E-004 8.345E-002 1.000 0.000 0.000 0.000
15 ROOM_1_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_1_FLR_6 39.02 1.5 2.275E-002 5.831E-004 2.881E-004 0.689 1.000 0.000 0.000 0.000
16 ROOM_2_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_2_FLR_6 39.02 1.5 2.275E-002 5.831E-004 2.881E-004 0.689 1.000 0.000 0.000 0.000
17 ROOM_3_MULT9_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH ROOM_3_MULT9_FLR_6 24.53 1.5 1.164E-002 4.746E-004 2.589E-004 0.561 1.000 0.000 0.000 0.000
18 BANQUET_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH BANQUET_FLR_6 331.66 249.9 5.556E-002 1.675E-004 1.295E-004 0.198 1.000 0.000 0.000 0.000
19 DINING_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH DINING_FLR_6 331.66 249.9 5.556E-002 1.675E-004 1.295E-004 0.198 1.000 0.000 0.000 0.000
20 KITCHEN_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH KITCHEN_FLR_6 103.30 22.2 4.974E-002 4.815E-004 2.609E-004 0.569 1.000 0.000 0.000 0.000
21 CORRIDOR_FLR_6_INFILTRATION INFIL_QUARTER_ON_SCH CORRIDOR_FLR_6 412.12 22.2 4.868E-002 1.181E-004 9.784E-005 0.140 1.000 0.000 0.000 0.000


ZoneVentilation Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/person Area {m3/s-person} ACH - Air Changes per Hour Fan Type {Exhaust;Intake;Natural} Fan Pressure Rise {Pa} Fan Efficiency {} Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2} Minimum Indoor Temperature{C}/Schedule Maximum Indoor Temperature{C}/Schedule Delta Temperature{C}/Schedule Minimum Outdoor Temperature{C}/Schedule Maximum Outdoor Temperature{C}/Schedule Maximum WindSpeed{m/s}
1 ROOM_1_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_1_FLR_3 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
2 ROOM_2_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_2_FLR_3 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
3 ROOM_3_MULT19_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_3_MULT19_FLR_3 24.52 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
4 ROOM_4_MULT19_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_4_MULT19_FLR_3 24.53 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
5 ROOM_5_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_5_FLR_3 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
6 ROOM_6_FLR_3 SLIDING DOOR VENTILATION Constant-0.0 ROOM_6_FLR_3 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
7 ROOM_1_FLR_6 SLIDING DOOR VENTILATION Constant-0.0 ROOM_1_FLR_6 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
8 ROOM_2_FLR_6 SLIDING DOOR VENTILATION Constant-0.0 ROOM_2_FLR_6 39.02 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
9 ROOM_3_MULT9_FLR_6 SLIDING DOOR VENTILATION Constant-0.0 ROOM_3_MULT9_FLR_6 24.53 1.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 BASEMENT Mixing/Well-Stirred
2 RETAIL_1_FLR_1 Mixing/Well-Stirred
3 RETAIL_2_FLR_1 Mixing/Well-Stirred
4 MECH_FLR_1 Mixing/Well-Stirred
5 STORAGE_FLR_1 Mixing/Well-Stirred
6 LAUNDRY_FLR_1 Mixing/Well-Stirred
7 CAFE_FLR_1 Mixing/Well-Stirred
8 LOBBY_FLR_1 Mixing/Well-Stirred
9 ROOM_1_FLR_3 Mixing/Well-Stirred
10 ROOM_2_FLR_3 Mixing/Well-Stirred
11 ROOM_3_MULT19_FLR_3 Mixing/Well-Stirred
12 ROOM_4_MULT19_FLR_3 Mixing/Well-Stirred
13 ROOM_5_FLR_3 Mixing/Well-Stirred
14 ROOM_6_FLR_3 Mixing/Well-Stirred
15 CORRIDOR_FLR_3 Mixing/Well-Stirred
16 ROOM_1_FLR_6 Mixing/Well-Stirred
17 ROOM_2_FLR_6 Mixing/Well-Stirred
18 ROOM_3_MULT9_FLR_6 Mixing/Well-Stirred
19 BANQUET_FLR_6 Mixing/Well-Stirred
20 DINING_FLR_6 Mixing/Well-Stirred
21 KITCHEN_FLR_6 Mixing/Well-Stirred
22 CORRIDOR_FLR_6 Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.0000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.0000


Sky Daylight Factors

Sky Type MonthAndDay Daylighting Control Name Enclosure Name Window Name Reference Point Daylight Factor
1 Clear Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT1 0.1676
2 Clear Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT2 0.1026
3 Clear Turbid Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT1 0.1980
4 Clear Turbid Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT2 0.1247
5 Intermediate Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT1 9.1965E-002
6 Intermediate Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT2 3.7622E-002
7 Overcast Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT1 4.7474E-002
8 Overcast Sky 01/21 LOBBY_FLR_1_DAYLCTRL LOBBY_FLR_1 LOBBY_FLR_1_WALL_SOUTH_WINDOW LOBBY_FLR_1_DAYLREFPT2 1.5758E-002
9 Clear Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT1 0.1870
10 Clear Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT2 0.1225
11 Clear Turbid Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT1 0.2208
12 Clear Turbid Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT2 0.1484
13 Intermediate Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT1 0.1018
14 Intermediate Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT2 4.7335E-002
15 Overcast Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT1 5.3310E-002
16 Overcast Sky 01/21 CAFE_FLR_1_DAYLCTRL CAFE_FLR_1 CAFE_FLR_1_WALL_SOUTH_WINDOW CAFE_FLR_1_DAYLREFPT2 2.1554E-002
17 Clear Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT1 5.5276E-002
18 Clear Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT2 3.1527E-002
19 Clear Turbid Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT1 4.4108E-002
20 Clear Turbid Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT2 2.4866E-002
21 Intermediate Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT1 3.7815E-002
22 Intermediate Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT2 1.4843E-002
23 Overcast Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT1 4.6736E-002
24 Overcast Sky 01/21 DINING_FLR_6_DAYLCTRL DINING_FLR_6 DINING_FLR_6_WALL_NORTH_WINDOW DINING_FLR_6_DAYLREFPT2 1.6558E-002
25 Clear Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT1 5.5276E-002
26 Clear Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT2 3.1527E-002
27 Clear Turbid Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT1 4.4108E-002
28 Clear Turbid Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT2 2.4866E-002
29 Intermediate Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT1 3.7815E-002
30 Intermediate Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT2 1.4843E-002
31 Overcast Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT1 4.6736E-002
32 Overcast Sky 01/21 BANQUET_FLR_6_DAYLCTRL BANQUET_FLR_6 BANQUET_FLR_6_WALL_NORTH_WINDOW BANQUET_FLR_6_DAYLREFPT2 1.6558E-002


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 BASEMENT Cooling 33393.80191 33393.80191 2.46464 2.46464 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42200 7.00114E-003 1978.83018 106.49900 0.85446 0.00000
2 BASEMENT Heating 3473.03351 3473.03351 0.15122 0.85446 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 1978.83018 106.49900 0.85446 0.00000
3 RETAIL_1_FLR_1 Cooling 7629.62960 7629.62960 0.56314 0.56314 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 27.40000 7.00714E-003 67.07136 10.82900 7.92179E-002 0.00000
4 RETAIL_1_FLR_1 Heating 4795.77234 4795.77234 0.20878 0.20878 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 67.07136 10.82900 7.92179E-002 0.00000
5 RETAIL_2_FLR_1 Cooling 3376.65741 3376.65741 0.24924 0.24924 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 27.09400 7.00668E-003 77.66889 12.54000 9.17347E-002 0.00000
6 RETAIL_2_FLR_1 Heating 1577.62899 1577.62899 6.86872E-002 9.17347E-002 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 77.66889 12.54000 9.17347E-002 0.00000
7 MECH_FLR_1 Cooling 3082.03390 3082.03390 0.22744 0.22744 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:20:00 27.19600 7.00683E-003 164.24319 2.65200 0.00000 0.00000
8 MECH_FLR_1 Heating 3001.61753 3001.61753 0.13068 0.13068 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 164.24319 2.65200 0.00000 0.00000
9 STORAGE_FLR_1 Cooling 1492.20422 1492.20422 0.11012 0.11012 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:10:00 27.29800 7.00699E-003 94.75927 2.04000 5.77652E-002 0.00000
10 STORAGE_FLR_1 Heating 1897.65814 1897.65814 8.26202E-002 8.26202E-002 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 94.75927 2.04000 5.77652E-002 0.00000
11 LAUNDRY_FLR_1 Cooling 44955.93738 44955.93738 3.31789 3.31789 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:50:00 27.40000 7.00714E-003 78.03947 8.40000 0.00000 0.00000
12 LAUNDRY_FLR_1 Heating 3989.18532 3989.18532 0.17367 0.17367 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 78.03947 8.40000 0.00000 0.00000
13 CAFE_FLR_1 Cooling 28308.98506 28308.98506 2.09111 2.09111 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 27.40000 7.00714E-003 188.86188 142.30000 0.67639 0.00000
14 CAFE_FLR_1 Heating 11971.05072 11971.05072 0.52117 0.67639 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 188.86188 142.30000 0.67639 0.00000
15 LOBBY_FLR_1 Cooling 73625.40191 73625.40191 5.43594 5.43594 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 27.40000 7.00714E-003 1308.18612 422.43500 1.89399 0.00000
16 LOBBY_FLR_1 Heating 28170.41650 28170.41650 1.22649 1.89399 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 1308.18612 422.43500 1.89399 0.00000
17 ROOM_1_FLR_3 Cooling 13138.47129 13138.47129 1.30662 1.30662 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 25.46200 7.00420E-003 39.02202 1.50000 6.17350E-002 0.00000
18 ROOM_1_FLR_3 Heating 10951.56408 10951.56408 0.47957 0.47957 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.02202 1.50000 6.17350E-002 0.00000
19 ROOM_2_FLR_3 Cooling 11722.58117 11722.58117 1.16581 1.16581 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 24.95200 7.00344E-003 39.01745 1.50000 6.17278E-002 0.00000
20 ROOM_2_FLR_3 Heating 10941.36172 10941.36172 0.47912 0.47912 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.01745 1.50000 6.17278E-002 0.00000
21 ROOM_3_MULT19_FLR_3 Cooling 96774.43130 96774.43130 9.62390 9.62390 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 27.40000 7.00714E-003 24.52384 1.50000 0.83707 0.00000
22 ROOM_3_MULT19_FLR_3 Heating 61702.12018 61702.12018 2.70214 2.70214 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 24.52384 1.50000 0.83707 0.00000
23 ROOM_4_MULT19_FLR_3 Cooling 58101.52927 58101.52927 5.77846 5.77846 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:20:00 21.07600 6.99765E-003 24.53055 1.50000 0.83730 0.00000
24 ROOM_4_MULT19_FLR_3 Heating 61554.79407 61554.79407 2.69568 2.69568 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 24.53055 1.50000 0.83730 0.00000
25 ROOM_5_FLR_3 Cooling 12346.38915 12346.38915 1.22785 1.22785 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:40:00 24.54400 7.00282E-003 39.02202 1.50000 6.17350E-002 0.00000
26 ROOM_5_FLR_3 Heating 10932.84852 10932.84852 0.47875 0.47875 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.02202 1.50000 6.17350E-002 0.00000
27 ROOM_6_FLR_3 Cooling 11087.72748 11087.72748 1.10267 1.10267 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 22.65700 7.00000E-003 39.01745 1.50000 6.17278E-002 0.00000
28 ROOM_6_FLR_3 Heating 10922.64765 10922.64765 0.47831 0.47831 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.01745 1.50000 6.17278E-002 0.00000
29 CORRIDOR_FLR_3 Cooling 23589.30239 23589.30239 1.74096 1.74096 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40000 7.00714E-003 389.40468 20.95700 0.47476 0.00000
30 CORRIDOR_FLR_3 Heating 16164.00432 16164.00432 0.70377 0.70377 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 389.40468 20.95700 0.47476 0.00000
31 ROOM_1_FLR_6 Cooling 3423.10807 3423.10807 0.34043 0.34043 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 25.46200 7.00420E-003 39.02202 1.50000 1.54338E-002 0.00000
32 ROOM_1_FLR_6 Heating 3345.28417 3345.28417 0.14649 0.14649 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.02202 1.50000 1.54338E-002 0.00000
33 ROOM_2_FLR_6 Cooling 3019.41345 3019.41345 0.30028 0.30028 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:10:00 24.69700 7.00305E-003 39.01745 1.50000 1.54319E-002 0.00000
34 ROOM_2_FLR_6 Heating 3341.80692 3341.80692 0.14634 0.14634 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 39.01745 1.50000 1.54319E-002 0.00000
35 ROOM_3_MULT9_FLR_6 Cooling 20354.29067 20354.29067 2.02429 2.02429 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 27.40000 7.00714E-003 24.53055 1.50000 9.91540E-002 0.00000
36 ROOM_3_MULT9_FLR_6 Heating 15986.67698 15986.67698 0.70008 0.70008 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 24.53055 1.50000 9.91540E-002 0.00000
37 BANQUET_FLR_6 Cooling 29057.01027 29057.01027 2.14714 2.14714 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 27.40000 7.00714E-003 331.65745 249.89600 1.18780 0.00000
38 BANQUET_FLR_6 Heating 10752.15092 10752.15092 0.46813 1.18780 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 331.65745 249.89600 1.18780 0.00000
39 DINING_FLR_6 Cooling 30427.68939 30427.68939 2.24839 2.24839 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 27.40000 7.00714E-003 331.65745 249.89600 1.18780 0.00000
40 DINING_FLR_6 Heating 10944.98055 10944.98055 0.47652 1.18780 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 331.65745 249.89600 1.18780 0.00000
41 KITCHEN_FLR_6 Cooling 32032.78200 32032.78200 2.37017 2.37017 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 12:30:00 26.48200 7.00575E-003 103.30446 22.23800 0.36735 0.00000
42 KITCHEN_FLR_6 Heating 5184.60685 5184.60685 0.22570 0.36735 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 -41.90000 6.45023E-005 103.30446 22.23800 0.36735 0.00000
43 CORRIDOR_FLR_6 Cooling 11696.74314 11696.74314 0.86325 0.86325 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40000 7.00714E-003 412.12471 22.18000 0.12562 0.00000
44 CORRIDOR_FLR_6 Heating 11208.85923 11208.85923 0.48802 0.48802 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 -41.90000 6.45023E-005 412.12471 22.18000 0.12562 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 VAV WITH REHEAT Cooling Sensible 363061.00 23.68416 23.68416 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 00:00:00
2 VAV WITH REHEAT Heating Sensible 561719.22 8.04706 8.04706 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00
3 FLR_3_DOAS Cooling Sensible 35674.24 20.77335 2.05125 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 00:00:00
4 FLR_3_DOAS Heating Sensible 143185.63 8.30648 2.05125 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 2.46464
2 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.61180
3 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
4 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.20521
5 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 1.00000
6 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
7 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 6.22751E-004
8 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 8.51883E-005
9 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.20521
10 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
11 AirTerminal:SingleDuct:VAV:Reheat BASEMENT VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
12 Coil:Heating:Water BASEMENT VAV BOX REHEAT COIL Design Size Rated Capacity [W] 9737.54202
13 Coil:Heating:Water BASEMENT VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 8.51883E-005
14 Coil:Heating:Water BASEMENT VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 209.08645
15 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.56314
16 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 9.07562E-002
17 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
18 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.27538
19 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
20 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
21 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 4.19806E-003
22 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 5.44612E-005
23 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.27538
24 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
25 AirTerminal:SingleDuct:VAV:Reheat RETAIL_1_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
26 Coil:Heating:Water RETAIL_1_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 6225.24597
27 Coil:Heating:Water RETAIL_1_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 5.44612E-005
28 Coil:Heating:Water RETAIL_1_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 157.80095
29 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.24924
30 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.23746
31 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
32 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.12188
33 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.63322
34 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
35 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.60450E-003
36 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.93377E-005
37 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.12188
38 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
39 AirTerminal:SingleDuct:VAV:Reheat RETAIL_2_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
40 Coil:Heating:Water RETAIL_2_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 2210.41533
41 Coil:Heating:Water RETAIL_2_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.93377E-005
42 Coil:Heating:Water RETAIL_2_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 53.03830
43 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.22744
44 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.55026
45 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
46 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.11122
47 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 1.00000
48 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
49 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 6.92401E-004
50 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 3.21939E-005
51 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.13068
52 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
53 AirTerminal:SingleDuct:VAV:Reheat MECH_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
54 Coil:Heating:Water MECH_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 3679.96020
55 Coil:Heating:Water MECH_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 3.21939E-005
56 Coil:Heating:Water MECH_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 100.42759
57 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.11012
58 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.65570
59 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
60 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 5.38491E-002
61 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 1.00000
62 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
63 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 5.81056E-004
64 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 2.03537E-005
65 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 8.26202E-002
66 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
67 AirTerminal:SingleDuct:VAV:Reheat STORAGE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
68 Coil:Heating:Water STORAGE_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 2326.55697
69 Coil:Heating:Water STORAGE_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 2.03537E-005
70 Coil:Heating:Water STORAGE_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 63.49311
71 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 3.31789
72 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 7.11217E-002
73 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
74 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.62245
75 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
76 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
77 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.12578E-002
78 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.08549E-004
79 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.62245
80 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
81 AirTerminal:SingleDuct:VAV:Reheat LAUNDRY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
82 Coil:Heating:Water LAUNDRY_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 12407.84626
83 Coil:Heating:Water LAUNDRY_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.08549E-004
84 Coil:Heating:Water LAUNDRY_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 265.24007
85 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 2.09111
86 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 6.88213E-002
87 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
88 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.02255
89 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
90 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
91 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 5.53608E-003
92 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.51174E-004
93 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.02255
94 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
95 AirTerminal:SingleDuct:VAV:Reheat CAFE_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
96 Coil:Heating:Water CAFE_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 17280.07270
97 Coil:Heating:Water CAFE_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.51174E-004
98 Coil:Heating:Water CAFE_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 408.68152
99 Fan:ZoneExhaust LOBBY_FLR_1 EXHAUST FAN User-Specified Maximum Flow Rate [m3/s] 0.00000
100 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 5.43594
101 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.18338
102 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
103 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 2.65817
104 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48901
105 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
106 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.07766E-003
107 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 3.67193E-004
108 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 2.65817
109 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
110 AirTerminal:SingleDuct:VAV:Reheat LOBBY_FLR_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
111 Coil:Heating:Water LOBBY_FLR_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 41972.45253
112 Coil:Heating:Water LOBBY_FLR_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 3.67193E-004
113 Coil:Heating:Water LOBBY_FLR_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 980.01587
114 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_1_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 6.17350E-002
115 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 1.30662
116 Fan:OnOff ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 1.30662
117 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 9.58091E-005
118 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 5.06573E-004
119 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69233
120 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
121 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53180E-003
122 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
123 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
124 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 5.06573E-004
125 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 1.30662
126 Coil:Heating:Water ROOM_1_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 10951.56408
127 Coil:Heating:Water ROOM_1_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 9.58091E-005
128 Coil:Heating:Water ROOM_1_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 312.94924
129 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_2_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 6.17278E-002
130 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 1.16581
131 Fan:OnOff ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 1.16581
132 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 9.57198E-005
133 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 4.52431E-004
134 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69232
135 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
136 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53538E-003
137 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
138 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
139 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 4.52431E-004
140 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 1.16581
141 Coil:Heating:Water ROOM_2_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 10941.36172
142 Coil:Heating:Water ROOM_2_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 9.57198E-005
143 Coil:Heating:Water ROOM_2_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 312.65777
144 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_3_MULT19_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.83707
145 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT19_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 9.62390
146 Fan:OnOff ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 9.62390
147 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT19_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 5.39797E-004
148 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT19_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 3.69825E-003
149 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69265
150 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
151 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.48217E-003
152 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
153 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.48217E-003
154 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 3.69825E-003
155 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 9.62390
156 Coil:Heating:Water ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 61702.12018
157 Coil:Heating:Water ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 5.39797E-004
158 Coil:Heating:Water ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 1763.18403
159 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_4_MULT19_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.83730
160 ZoneHVAC:FourPipeFanCoil ROOM_4_MULT19_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 5.77846
161 Fan:OnOff ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 5.77846
162 ZoneHVAC:FourPipeFanCoil ROOM_4_MULT19_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 5.38508E-004
163 ZoneHVAC:FourPipeFanCoil ROOM_4_MULT19_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 2.35232E-003
164 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69178
165 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
166 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.71220E-003
167 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
168 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
169 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 2.35232E-003
170 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 5.77846
171 Coil:Heating:Water ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 61554.79407
172 Coil:Heating:Water ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 5.38508E-004
173 Coil:Heating:Water ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 1758.97518
174 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_5_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 6.17350E-002
175 ZoneHVAC:FourPipeFanCoil ROOM_5_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 1.22785
176 Fan:OnOff ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 1.22785
177 ZoneHVAC:FourPipeFanCoil ROOM_5_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 9.56453E-005
178 ZoneHVAC:FourPipeFanCoil ROOM_5_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 4.76269E-004
179 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69233
180 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
181 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53358E-003
182 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
183 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
184 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 4.76269E-004
185 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 1.22785
186 Coil:Heating:Water ROOM_5_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 10932.84852
187 Coil:Heating:Water ROOM_5_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 9.56453E-005
188 Coil:Heating:Water ROOM_5_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 312.41456
189 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_6_FLR_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 6.17278E-002
190 ZoneHVAC:FourPipeFanCoil ROOM_6_FLR_3 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 1.10267
191 Fan:OnOff ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 1.10267
192 ZoneHVAC:FourPipeFanCoil ROOM_6_FLR_3 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 9.55561E-005
193 ZoneHVAC:FourPipeFanCoil ROOM_6_FLR_3 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 4.28132E-004
194 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69232
195 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
196 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53710E-003
197 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
198 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
199 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 4.28132E-004
200 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 1.10267
201 Coil:Heating:Water ROOM_6_FLR_3 FAN COIL HEATING COIL Design Size Rated Capacity [W] 10922.64765
202 Coil:Heating:Water ROOM_6_FLR_3 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 9.55561E-005
203 Coil:Heating:Water ROOM_6_FLR_3 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 312.12313
204 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 1.74096
205 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.68175
206 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
207 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.85133
208 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 1.00000
209 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
210 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 5.58853E-004
211 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.80092E-004
212 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.85133
213 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
214 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
215 Coil:Heating:Water CORRIDOR_FLR_3 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 20585.67544
216 Coil:Heating:Water CORRIDOR_FLR_3 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.80092E-004
217 Coil:Heating:Water CORRIDOR_FLR_3 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 532.44762
218 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_1_FLR_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 1.54338E-002
219 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_6 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 0.34043
220 Fan:OnOff ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 0.34043
221 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_6 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 2.92660E-005
222 ZoneHVAC:FourPipeFanCoil ROOM_1_FLR_6 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 1.31936E-004
223 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69233
224 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
225 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53053E-003
226 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
227 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
228 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 1.31936E-004
229 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 0.34043
230 Coil:Heating:Water ROOM_1_FLR_6 FAN COIL HEATING COIL Design Size Rated Capacity [W] 3345.28417
231 Coil:Heating:Water ROOM_1_FLR_6 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 2.92660E-005
232 Coil:Heating:Water ROOM_1_FLR_6 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 95.58972
233 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_2_FLR_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 1.54319E-002
234 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_6 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 0.30028
235 Fan:OnOff ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 0.30028
236 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_6 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 2.92356E-005
237 ZoneHVAC:FourPipeFanCoil ROOM_2_FLR_6 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 1.16505E-004
238 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69233
239 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
240 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.53448E-003
241 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
242 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
243 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 1.16505E-004
244 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 0.30028
245 Coil:Heating:Water ROOM_2_FLR_6 FAN COIL HEATING COIL Design Size Rated Capacity [W] 3341.80692
246 Coil:Heating:Water ROOM_2_FLR_6 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 2.92356E-005
247 Coil:Heating:Water ROOM_2_FLR_6 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 95.49038
248 AirTerminal:SingleDuct:ConstantVolume:NoReheat ROOM_3_MULT9_FLR_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 9.91540E-002
249 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT9_FLR_6 FAN COIL Design Size Maximum Supply Air Flow Rate [m3/s] 2.02429
250 Fan:OnOff ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN Design Size Maximum Flow Rate [m3/s] 2.02429
251 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT9_FLR_6 FAN COIL Design Size Maximum Hot Water Flow [m3/s] 1.39858E-004
252 ZoneHVAC:FourPipeFanCoil ROOM_3_MULT9_FLR_6 FAN COIL Design Size Maximum Cold Water Flow [m3/s] 7.91822E-004
253 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Temperature [C] 21.69207
254 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
255 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.56409E-003
256 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Temperature [C] 12.80000
257 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
258 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Water Flow Rate [m3/s] 7.91822E-004
259 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Design Size Design Air Flow Rate [m3/s] 2.02429
260 Coil:Heating:Water ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL Design Size Rated Capacity [W] 15986.67698
261 Coil:Heating:Water ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 1.39858E-004
262 Coil:Heating:Water ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL Design Size U-Factor Times Area Value [W/K] 456.80971
263 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 2.14714
264 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.11770
265 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
266 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.04995
267 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
268 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
269 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 3.23699E-003
270 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.41775E-004
271 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.04995
272 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
273 AirTerminal:SingleDuct:VAV:Reheat BANQUET_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
274 Coil:Heating:Water BANQUET_FLR_6 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 16205.69950
275 Coil:Heating:Water BANQUET_FLR_6 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.41775E-004
276 Coil:Heating:Water BANQUET_FLR_6 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 376.85216
277 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 2.24839
278 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.11240
279 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
280 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.09946
281 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
282 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
283 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 3.38963E-003
284 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.45712E-004
285 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.09946
286 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
287 AirTerminal:SingleDuct:VAV:Reheat DINING_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
288 Coil:Heating:Water DINING_FLR_6 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 16655.75418
289 Coil:Heating:Water DINING_FLR_6 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.45712E-004
290 Coil:Heating:Water DINING_FLR_6 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 386.05938
291 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 2.37017
292 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 5.97358E-002
293 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
294 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.15902
295 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.48900
296 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
297 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.14718E-002
298 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 9.79520E-005
299 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.15902
300 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
301 AirTerminal:SingleDuct:VAV:Reheat KITCHEN_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
302 Coil:Heating:Water KITCHEN_FLR_6 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 11196.51067
303 Coil:Heating:Water KITCHEN_FLR_6 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 9.79520E-005
304 Coil:Heating:Water KITCHEN_FLR_6 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 244.41642
305 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.86325
306 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.36379
307 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.48900
308 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.42213
309 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.97010
310 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
311 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.04731E-003
312 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.20239E-004
313 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.48802
314 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 16.70000
315 AirTerminal:SingleDuct:VAV:Reheat CORRIDOR_FLR_6 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
316 Coil:Heating:Water CORRIDOR_FLR_6 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 13744.04547
317 Coil:Heating:Water CORRIDOR_FLR_6 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.20239E-004
318 Coil:Heating:Water CORRIDOR_FLR_6 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 375.09988
319 AirLoopHVAC VAV WITH REHEAT Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 11.91472
320 AirLoopHVAC VAV WITH REHEAT Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 11.65259
321 AirLoopHVAC VAV WITH REHEAT Sum of Air Terminal Maximum Flow Rates [m3/s] 23.82943
322 AirLoopHVAC VAV WITH REHEAT Adjusted Heating Design Air Flow Rate [m3/s] 11.65259
323 AirLoopHVAC VAV WITH REHEAT Adjusted Cooling Design Air Flow Rate [m3/s] 23.68416
324 AirLoopHVAC VAV WITH REHEAT Adjusted Main Design Air Flow Rate [m3/s] 23.68416
325 AirLoopHVAC VAV WITH REHEAT User Heating Air Flow Ratio [] 0.30000
326 AirLoopHVAC VAV WITH REHEAT Calculated Heating Air Flow Ratio [] 0.49200
327 AirLoopHVAC FLR_3_DOAS Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 2.05132
328 AirLoopHVAC FLR_3_DOAS Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 2.05132
329 AirLoopHVAC FLR_3_DOAS Sum of Air Terminal Maximum Flow Rates [m3/s] 2.05132
330 AirLoopHVAC FLR_3_DOAS Adjusted Heating Design Air Flow Rate [m3/s] 2.05132
331 AirLoopHVAC FLR_3_DOAS Adjusted Cooling Design Air Flow Rate [m3/s] 2.05132
332 AirLoopHVAC FLR_3_DOAS Adjusted Main Design Air Flow Rate [m3/s] 2.05132
333 AirLoopHVAC FLR_3_DOAS User Heating Air Flow Ratio [] 0.30000
334 AirLoopHVAC FLR_3_DOAS Calculated Heating Air Flow Ratio [] 1.00000
335 AirLoopHVAC VAV WITH REHEAT Design Supply Air Flow Rate [m3/s] 23.68416
336 AirLoopHVAC FLR_3_DOAS Design Supply Air Flow Rate [m3/s] 2.05132
337 Controller:OutdoorAir VAV WITH REHEAT_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 23.68416
338 Controller:OutdoorAir VAV WITH REHEAT_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 11.66146
339 HeatExchanger:AirToAir:SensibleAndLatent VAV WITH REHEAT OA HEAT RECOVERY Design Size Nominal Supply Air Flow Rate [m3/s] 11.66146
340 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Inlet Air Temperature [C] 25.66878
341 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
342 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Outlet Air Temperature [C] 10.94741
343 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.29822E-003
344 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.29822E-003
345 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Coil Load [W] 421695.41800
346 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Water Flow Rate [m3/s] 1.50620E-002
347 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL Design Size Design Air Flow Rate [m3/s] 23.68416
348 Coil:Heating:Water VAV WITH REHEAT HEATING COIL Design Size Rated Capacity [W] 495976.60316
349 Coil:Heating:Water VAV WITH REHEAT HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 4.33902E-003
350 Coil:Heating:Water VAV WITH REHEAT HEATING COIL Design Size U-Factor Times Area Value [W/K] 6515.43054
351 Fan:VariableVolume VAV WITH REHEAT FAN Design Size Maximum Flow Rate [m3/s] 23.68416
352 Controller:WaterCoil VAV WITH REHEAT_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 1.50620E-002
353 Controller:WaterCoil VAV WITH REHEAT_COOLC_CONTROLLER Controller Convergence Tolerance 3.16154E-005
354 Controller:WaterCoil VAV WITH REHEAT_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 4.33902E-003
355 Controller:OutdoorAir FLR_3_DOAS_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 2.05132
356 Controller:OutdoorAir FLR_3_DOAS_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.05125
357 HeatExchanger:AirToAir:SensibleAndLatent FLR_3_DOAS OA HEAT RECOVERY Design Size Nominal Supply Air Flow Rate [m3/s] 2.05125
358 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Inlet Air Temperature [C] 27.40000
359 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Inlet Water Temperature [C] 6.70000
360 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Outlet Air Temperature [C] 11.91318
361 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 7.00714E-003
362 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 7.00714E-003
363 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Coil Load [W] 38332.29647
364 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Water Flow Rate [m3/s] 1.36914E-003
365 Coil:Cooling:Water FLR_3_DOAS COOLING COIL Design Size Design Air Flow Rate [m3/s] 2.05132
366 Coil:Heating:Water FLR_3_DOAS HEATING COIL Design Size Rated Capacity [W] 42957.20027
367 Coil:Heating:Water FLR_3_DOAS HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 3.75808E-004
368 Coil:Heating:Water FLR_3_DOAS HEATING COIL Design Size U-Factor Times Area Value [W/K] 564.31020
369 Fan:ConstantVolume FLR_3_DOAS FAN User-Specified Maximum Flow Rate [m3/s] 2.05125
370 Controller:WaterCoil FLR_3_DOAS_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 1.36914E-003
371 Controller:WaterCoil FLR_3_DOAS_COOLC_CONTROLLER Controller Convergence Tolerance 3.47802E-004
372 Controller:WaterCoil FLR_3_DOAS_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 3.75808E-004
373 Pump:VariableSpeed COOLSYS1 PUMP SECONDARY Design Flow Rate [m3/s] 2.53854E-002
374 Pump:VariableSpeed COOLSYS1 PUMP SECONDARY Design Power Consumption [W] 5230.98187
375 PlantLoop HEATSYS1 Maximum Loop Flow Rate [m3/s] 7.89844E-003
376 PlantLoop HEATSYS1 Plant Loop Volume [m3] 0.94781
377 Pump:VariableSpeed HEATSYS1 PUMP Design Flow Rate [m3/s] 7.89844E-003
378 Pump:VariableSpeed HEATSYS1 PUMP Design Power Consumption [W] 2378.66452
379 Pump:VariableSpeed HEATSYS1 PUMP Design Minimum Flow Rate [m3/s] 0.00000
380 Boiler:HotWater HEATSYS1 BOILER Design Size Nominal Capacity [W] 902840.68495
381 Boiler:HotWater HEATSYS1 BOILER User-Specified Nominal Capacity [W] 902840.68000
382 Boiler:HotWater HEATSYS1 BOILER Design Size Design Water Flow Rate [m3/s] 7.89844E-003
383 PlantLoop COOLSYS1 Maximum Loop Flow Rate [m3/s] 2.53854E-002
384 PlantLoop COOLSYS1 Plant Loop Volume [m3] 3.04624
385 Pump:ConstantSpeed COOLSYS1 PUMP Design Flow Rate [m3/s] 2.53854E-002
386 Pump:ConstantSpeed COOLSYS1 PUMP Design Power Consumption [W] 3621.58518
387 Chiller:Electric:EIR COOLSYS1 CHILLER1 Design Size Reference Chilled Water Flow Rate [m3/s] 2.53854E-002
388 Chiller:Electric:EIR COOLSYS1 CHILLER1 Design Size Reference Capacity [W] 710722.47950
389 Chiller:Electric:EIR COOLSYS1 CHILLER1 User-Specified Reference Capacity [W] 711369.19000
390 Chiller:Electric:EIR COOLSYS1 CHILLER1 Design Size Reference Condenser Fluid Flow Rate [m3/s] 81.09609
391 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 3.75036E-004
392 PlantLoop SWHSYS1 Plant Loop Volume [m3] 4.50044E-002
393 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 3.75036E-004
394 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 47.90688
395 WaterHeater:Mixed SWHSYS1 WATER HEATER Use Side Design Flow Rate [m3/s] 3.75036E-004


Water Heating Coil Capacity Information

Component Type Name Nominal Total Capacity {W}
1 Coil:Heating:Water BASEMENT VAV BOX REHEAT COIL 9786.56
2 Coil:Heating:Water RETAIL_1_FLR_1 VAV BOX REHEAT COIL 6251.13
3 Coil:Heating:Water RETAIL_2_FLR_1 VAV BOX REHEAT COIL 2220.13
4 Coil:Heating:Water MECH_FLR_1 VAV BOX REHEAT COIL 3693.93
5 Coil:Heating:Water STORAGE_FLR_1 VAV BOX REHEAT COIL 2335.39
6 Coil:Heating:Water LAUNDRY_FLR_1 VAV BOX REHEAT COIL 12470.56
7 Coil:Heating:Water CAFE_FLR_1 VAV BOX REHEAT COIL 17358.26
8 Coil:Heating:Water LOBBY_FLR_1 VAV BOX REHEAT COIL 42164.60
9 Coil:Heating:Water ROOM_1_FLR_3 FAN COIL HEATING COIL 11795.54
10 Coil:Heating:Water ROOM_2_FLR_3 FAN COIL HEATING COIL 11784.55
11 Coil:Heating:Water ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL 66457.98
12 Coil:Heating:Water ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL 66299.33
13 Coil:Heating:Water ROOM_5_FLR_3 FAN COIL HEATING COIL 11775.38
14 Coil:Heating:Water ROOM_6_FLR_3 FAN COIL HEATING COIL 11764.39
15 Coil:Heating:Water CORRIDOR_FLR_3 VAV BOX REHEAT COIL 20668.28
16 Coil:Heating:Water ROOM_1_FLR_6 FAN COIL HEATING COIL 3602.99
17 Coil:Heating:Water ROOM_2_FLR_6 FAN COIL HEATING COIL 3599.25
18 Coil:Heating:Water ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL 17218.29
19 Coil:Heating:Water BANQUET_FLR_6 VAV BOX REHEAT COIL 16280.17
20 Coil:Heating:Water DINING_FLR_6 VAV BOX REHEAT COIL 16732.53
21 Coil:Heating:Water KITCHEN_FLR_6 VAV BOX REHEAT COIL 11252.07
22 Coil:Heating:Water CORRIDOR_FLR_6 VAV BOX REHEAT COIL 13796.20
23 Coil:Heating:Water VAV WITH REHEAT HEATING COIL 263444.45
24 Coil:Heating:Water FLR_3_DOAS HEATING COIL 22817.28


Water Cooling Coil Capacity Information

Component Type Name Nominal Total Capacity {W} Nominal Sensible Capacity {W} Nominal Latent Capacity {W} Nominal Sensible Heat Ratio Nominal Coil UA Value {W/C} Nominal Coil Surface Area {m2}
1 Coil:Cooling:Water ROOM_1_FLR_3 FAN COIL COOLING COIL 21458.84 17343.32 4115.52 0.81 2468.26 25.03
2 Coil:Cooling:Water ROOM_2_FLR_3 FAN COIL COOLING COIL 19158.79 15480.38 3678.41 0.81 2203.46 22.35
3 Coil:Cooling:Water ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL 157385.90 127493.37 29892.53 0.81 18182.85 184.42
4 Coil:Cooling:Water ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL 97962.14 78189.04 19773.10 0.80 11211.87 113.72
5 Coil:Cooling:Water ROOM_5_FLR_3 FAN COIL COOLING COIL 20171.70 16300.93 3870.77 0.81 2320.08 23.53
6 Coil:Cooling:Water ROOM_6_FLR_3 FAN COIL COOLING COIL 18126.87 14644.77 3482.10 0.81 2084.67 21.14
7 Coil:Cooling:Water ROOM_1_FLR_6 FAN COIL COOLING COIL 5589.61 4518.01 1071.60 0.81 642.96 6.52
8 Coil:Cooling:Water ROOM_2_FLR_6 FAN COIL COOLING COIL 4933.97 3986.93 947.04 0.81 567.47 5.76
9 Coil:Cooling:Water ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL 33439.67 26964.00 6475.67 0.81 3842.63 38.97
10 Coil:Cooling:Water VAV WITH REHEAT COOLING COIL 552805.70 395252.20 157553.50 0.71 70587.17 715.93
11 Coil:Cooling:Water FLR_3_DOAS COOLING COIL 52427.63 36468.44 15959.19 0.70 7931.52 80.45


Chiller Standard Rating Information

Component Type Component Name IPLV in SI Units {W/W} IPLV in IP Units {Btu/W-h}
1 Chiller:Electric:EIR COOLSYS1 CHILLER1 3.93 13.40


Zone Surfaces

Zone Name # Surfaces
1 BASEMENT 14
2 RETAIL_1_FLR_1 8
3 RETAIL_2_FLR_1 8
4 MECH_FLR_1 7
5 STORAGE_FLR_1 8
6 LAUNDRY_FLR_1 8
7 CAFE_FLR_1 10
8 LOBBY_FLR_1 22
9 ROOM_1_FLR_3 9
10 ROOM_2_FLR_3 9
11 ROOM_3_MULT19_FLR_3 8
12 ROOM_4_MULT19_FLR_3 8
13 ROOM_5_FLR_3 9
14 ROOM_6_FLR_3 9
15 CORRIDOR_FLR_3 25
16 ROOM_1_FLR_6 9
17 ROOM_2_FLR_6 9
18 ROOM_3_MULT9_FLR_6 8
19 BANQUET_FLR_6 8
20 DINING_FLR_6 8
21 KITCHEN_FLR_6 12
22 CORRIDOR_FLR_6 19


HeatTransfer Surface

Surface Name Surface Class Base Surface Heat Transfer Algorithm Construction Nominal U (w/o film coefs) {W/m2-K} Nominal U (with film coefs) {W/m2-K} Solar Diffusing Area (Net) {m2} Area (Gross) {m2} Area (Sunlit Calc) {m2} Azimuth {deg} Tilt {deg} ~Width {m} ~Height {m} Reveal {m} ExtBoundCondition ExtConvCoeffCalc IntConvCoeffCalc SunExposure WindExposure ViewFactorToGround ViewFactorToSky ViewFactorToGround-IR ViewFactorToSky-IR #Sides
1 BASEMENT_WALL_NORTH Wall   CTF - ConductionTransferFunction BASEMENT_WALL_NORTH_CFACTOR 0.354 0.336   211.13 211.13 211.13 0.00 90.00 86.56 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
2 BASEMENT_WALL_EAST Wall   CTF - ConductionTransferFunction BASEMENT_WALL_EAST_CFACTOR 0.354 0.336   55.76 55.76 55.76 90.00 90.00 22.86 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
3 BASEMENT_WALL_SOUTH Wall   CTF - ConductionTransferFunction BASEMENT_WALL_SOUTH_CFACTOR 0.354 0.336   211.13 211.13 211.13 180.00 90.00 86.56 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
4 BASEMENT_WALL_WEST Wall   CTF - ConductionTransferFunction BASEMENT_WALL_WEST_CFACTOR 0.354 0.336   55.76 55.76 55.76 270.00 90.00 22.86 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
5 BASEMENT_FLOOR Floor   CTF - ConductionTransferFunction BASEMENT_FLOOR 2.705 1.632   1978.83 1978.83 1978.83 0.00 180.00 86.56 22.86 0.00 BASEMENT_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
6 BASEMENT_CEILING_1 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   67.07 67.07 67.07 180.00 0.00 11.58 5.79 0.00 RETAIL_1_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
7 BASEMENT_CEILING_2 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   77.67 77.67 77.67 180.00 0.00 11.58 6.71 0.00 RETAIL_2_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
8 BASEMENT_CEILING_3 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   164.24 164.24 164.24 180.00 0.00 15.85 10.36 0.00 MECH_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
9 BASEMENT_CEILING_4 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   94.76 94.76 94.76 180.00 0.00 9.14 10.36 0.00 STORAGE_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
10 BASEMENT_CEILING_5 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   78.04 78.04 78.04 180.00 0.00 4.57 17.07 0.00 LAUNDRY_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
11 BASEMENT_CEILING_6 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   188.86 188.86 188.86 180.00 0.00 32.61 5.79 0.00 CAFE_FLR_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
12 BASEMENT_CEILING_7 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   1088.56 1088.56 1088.56 180.00 0.00 32.99 32.99 0.00 LOBBY_FLR_1_FLOOR_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 6
13 BASEMENT_CEILING_8 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   219.63 219.63 219.63 90.00 0.00 14.82 14.82 0.00 LOBBY_FLR_1_FLOOR_2 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 6
14 BASEMENT_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   3957.66 3957.66 3957.66 0.00 90.00 3957.66 1.00 0.00 BASEMENT_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
15 RETAIL_1_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   22.63 45.89 22.63 180.00 90.00 11.58 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
16 RETAIL_1_FLR_1_WALL_SOUTH_WINDOW Window RETAIL_1_FLR_1_WALL_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 23.26 23.26 23.26 180.00 90.00 10.92 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
17 RETAIL_1_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   22.95 22.95 22.95 270.00 90.00 5.79 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
18 RETAIL_1_FLR_1_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   45.89 45.89 45.89 0.00 90.00 11.58 3.96 0.00 RETAIL_2_FLR_1_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
19 RETAIL_1_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   22.95 22.95 22.95 90.00 90.00 5.79 3.96 0.00 LOBBY_FLR_1_WALL_2_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
20 RETAIL_1_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   67.07 67.07 67.07 0.00 180.00 11.58 5.79 0.00 BASEMENT_CEILING_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
21 RETAIL_1_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   67.07 67.07 67.07 180.00 0.00 11.58 5.79 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 7.62E-002 0.92 4
22 RETAIL_1_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   134.14 134.14 134.14 0.00 90.00 134.14 1.00 0.00 RETAIL_1_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
23 RETAIL_2_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   24.62 26.57 24.62 270.00 90.00 6.71 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
24 RETAIL_2_FLR_1_WALL_WEST_DOOR Door RETAIL_2_FLR_1_WALL_WEST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 270.00 90.00 0.91 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
25 RETAIL_2_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   45.89 45.89 45.89 180.00 90.00 11.58 3.96 0.00 RETAIL_1_FLR_1_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
26 RETAIL_2_FLR_1_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   45.89 45.89 45.89 0.00 90.00 11.58 3.96 0.00 LOBBY_FLR_1_WALL_2_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
27 RETAIL_2_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.57 26.57 26.57 90.00 90.00 6.71 3.96 0.00 LOBBY_FLR_1_WALL_3_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
28 RETAIL_2_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   77.67 77.67 77.67 0.00 180.00 11.58 6.71 0.00 BASEMENT_CEILING_2 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
29 RETAIL_2_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   77.67 77.67 77.67 180.00 0.00 11.58 6.71 0.00 RETAIL_2_FLR_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
30 RETAIL_2_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   155.34 155.34 155.34 0.00 90.00 155.34 1.00 0.00 RETAIL_2_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
31 MECH_FLR_1_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   62.80 62.80 62.80 0.00 90.00 15.85 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
32 MECH_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 90.00 90.00 10.36 3.96 0.00 STORAGE_FLR_1_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
33 MECH_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   62.80 62.80 62.80 180.00 90.00 15.85 3.96 0.00 LOBBY_FLR_1_WALL_3_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
34 MECH_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 270.00 90.00 10.36 3.96 0.00 LOBBY_FLR_1_WALL_1_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
35 MECH_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   164.24 164.24 164.24 0.00 180.00 15.85 10.36 0.00 BASEMENT_CEILING_3 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
36 MECH_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   164.24 164.24 164.24 180.00 0.00 15.85 10.36 0.00 MECH_FLR_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
37 MECH_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   328.49 328.49 328.49 0.00 90.00 328.49 1.00 0.00 MECH_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
38 STORAGE_FLR_1_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   28.80 36.23 28.80 0.00 90.00 9.14 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
39 STORAGE_FLR_1_WALL_NORTH_ROLLDOOR Door STORAGE_FLR_1_WALL_NORTH CTF - ConductionTransferFunction OVERHEAD DOOR_CON 1.198 1.198   7.43 7.43 7.43 0.00 90.00 3.05 2.44 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
40 STORAGE_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 90.00 90.00 10.36 3.96 0.00 LOBBY_FLR_1_WALL_4_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
41 STORAGE_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   36.23 36.23 36.23 180.00 90.00 9.14 3.96 0.00 LOBBY_FLR_1_WALL_4_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
42 STORAGE_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 270.00 90.00 10.36 3.96 0.00 MECH_FLR_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
43 STORAGE_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   94.76 94.76 94.76 0.00 180.00 9.14 10.36 0.00 BASEMENT_CEILING_4 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
44 STORAGE_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   94.76 94.76 94.76 180.00 0.00 9.14 10.36 0.00 STORAGE_FLR_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
45 STORAGE_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   189.52 189.52 189.52 0.00 90.00 189.52 1.00 0.00 STORAGE_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
46 LAUNDRY_FLR_1_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   18.12 18.12 18.12 0.00 90.00 4.57 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
47 LAUNDRY_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   65.68 67.63 65.68 90.00 90.00 17.07 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
48 LAUNDRY_FLR_1_WALL_EAST_DOOR Door LAUNDRY_FLR_1_WALL_EAST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 90.00 90.00 0.91 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
49 LAUNDRY_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   18.12 18.12 18.12 180.00 90.00 4.57 3.96 0.00 CAFE_FLR_1_WALL_2_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
50 LAUNDRY_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   67.63 67.63 67.63 270.00 90.00 17.07 3.96 0.00 LOBBY_FLR_1_WALL_3_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
51 LAUNDRY_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   78.04 78.04 78.04 0.00 180.00 4.57 17.07 0.00 BASEMENT_CEILING_5 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
52 LAUNDRY_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   78.04 78.04 78.04 180.00 0.00 4.57 17.07 0.00 LAUNDRY_FLR_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
53 LAUNDRY_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   156.08 156.08 156.08 0.00 90.00 156.08 1.00 0.00 LAUNDRY_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
54 CAFE_FLR_1_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   21.00 22.95 21.00 90.00 90.00 5.79 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
55 CAFE_FLR_1_WALL_EAST_DOOR Door CAFE_FLR_1_WALL_EAST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 90.00 90.00 0.91 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
56 CAFE_FLR_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   63.73 129.23 63.73 180.00 90.00 32.61 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
57 CAFE_FLR_1_WALL_SOUTH_WINDOW Window CAFE_FLR_1_WALL_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 65.50 65.50 65.50 180.00 90.00 30.75 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
58 CAFE_FLR_1_WALL_1_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   111.11 111.11 111.11 0.00 90.00 28.04 3.96 0.00 LOBBY_FLR_1_WALL_3_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
59 CAFE_FLR_1_WALL_2_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   18.12 18.12 18.12 0.00 90.00 4.57 3.96 0.00 LAUNDRY_FLR_1_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
60 CAFE_FLR_1_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   22.95 22.95 22.95 270.00 90.00 5.79 3.96 0.00 LOBBY_FLR_1_WALL_2_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
61 CAFE_FLR_1_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   188.86 188.86 188.86 0.00 180.00 32.61 5.79 0.00 BASEMENT_CEILING_6 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
62 CAFE_FLR_1_CEILING Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   188.86 188.86 188.86 180.00 0.00 32.61 5.79 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 3.86E-002 0.96 4
63 CAFE_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   377.72 377.72 377.72 0.00 90.00 377.72 1.00 0.00 CAFE_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
64 LOBBY_FLR_1_WALL_1_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   209.87 213.77 209.87 0.00 90.00 53.95 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
65 LOBBY_FLR_1_WALL_1_NORTH_DOOR1 Door LOBBY_FLR_1_WALL_1_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
66 LOBBY_FLR_1_WALL_1_NORTH_DOOR2 Door LOBBY_FLR_1_WALL_1_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
67 LOBBY_FLR_1_WALL_2_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   12.08 12.08 12.08 0.00 90.00 3.05 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
68 LOBBY_FLR_1_WALL_1_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   82.79 167.88 82.79 180.00 90.00 42.37 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
69 LOBBY_FLR_1_WALL_SOUTH_WINDOW Window LOBBY_FLR_1_WALL_1_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 85.08 85.08 85.08 180.00 90.00 39.95 2.13 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
70 LOBBY_FLR_1_WALL_1_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.620 0.568   41.06 41.06 41.06 270.00 90.00 10.36 3.96 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
71 LOBBY_FLR_1_WALL_2_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   45.89 45.89 45.89 180.00 90.00 11.58 3.96 0.00 RETAIL_2_FLR_1_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
72 LOBBY_FLR_1_WALL_3_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   111.11 111.11 111.11 180.00 90.00 28.04 3.96 0.00 CAFE_FLR_1_WALL_1_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
73 LOBBY_FLR_1_WALL_2_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   22.95 22.95 22.95 270.00 90.00 5.79 3.96 0.00 RETAIL_1_FLR_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
74 LOBBY_FLR_1_WALL_3_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.57 26.57 26.57 270.00 90.00 6.71 3.96 0.00 RETAIL_2_FLR_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
75 LOBBY_FLR_1_WALL_4_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 270.00 90.00 10.36 3.96 0.00 STORAGE_FLR_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
76 LOBBY_FLR_1_WALL_3_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   62.80 62.80 62.80 0.00 90.00 15.85 3.96 0.00 MECH_FLR_1_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
77 LOBBY_FLR_1_WALL_4_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   36.23 36.23 36.23 0.00 90.00 9.14 3.96 0.00 STORAGE_FLR_1_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
78 LOBBY_FLR_1_WALL_1_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   41.06 41.06 41.06 90.00 90.00 10.36 3.96 0.00 MECH_FLR_1_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
79 LOBBY_FLR_1_WALL_2_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   22.95 22.95 22.95 90.00 90.00 5.79 3.96 0.00 CAFE_FLR_1_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
80 LOBBY_FLR_1_WALL_3_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   67.63 67.63 67.63 90.00 90.00 17.07 3.96 0.00 LAUNDRY_FLR_1_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
81 LOBBY_FLR_1_FLOOR_1 Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   1088.56 1088.56 1088.56 180.00 180.00 32.99 32.99 0.00 BASEMENT_CEILING_7 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 6
82 LOBBY_FLR_1_FLOOR_2 Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   219.63 219.63 219.63 90.00 180.00 14.82 14.82 0.00 BASEMENT_CEILING_8 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 6
83 LOBBY_FLR_1_CEILING_1 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   1062.83 1062.83 1062.83 270.00 0.00 32.60 32.60 0.00 LOBBY_FLR_1_CEILING_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 10
84 LOBBY_FLR_1_CEILING_2 Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   245.35 245.35 245.35 180.00 0.00 42.37 5.79 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 4.22E-003 1.00 4
85 LOBBY_FLR_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   2616.37 2616.37 2616.37 0.00 90.00 2616.37 1.00 0.00 LOBBY_FLR_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
86 ROOM_1_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   9.34 13.94 9.34 180.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
87 ROOM_1_FLR_3_WALL_SOUTH_WINDOW Window ROOM_1_FLR_3_WALL_SOUTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 180.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
88 ROOM_1_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   17.43 26.01 17.43 270.00 90.00 8.54 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
89 ROOM_1_FLR_3_WALL_WEST_WINDOW Window ROOM_1_FLR_3_WALL_WEST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 270.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
90 ROOM_1_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 0.00 90.00 4.57 3.05 0.00 ROOM_2_FLR_3_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
91 ROOM_1_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.54 3.05 0.00 CORRIDOR_FLR_3_WALL_3_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
92 ROOM_1_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.54 0.00 ROOM_1_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
93 ROOM_1_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   39.02 39.02 39.02 180.00 0.00 4.57 8.54 0.00 ROOM_1_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
94 ROOM_1_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.04 78.04 78.04 0.00 90.00 78.04 1.00 0.00 ROOM_1_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
95 ROOM_2_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   9.34 13.94 9.34 0.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
96 ROOM_2_FLR_3_WALL_NORTH_WINDOW Window ROOM_2_FLR_3_WALL_NORTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 0.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
97 ROOM_2_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   17.43 26.01 17.43 270.00 90.00 8.53 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
98 ROOM_2_FLR_3_WALL_WEST_WINDOW Window ROOM_2_FLR_3_WALL_WEST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 270.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
99 ROOM_2_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.53 3.05 0.00 CORRIDOR_FLR_3_WALL_4_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
100 ROOM_2_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 180.00 90.00 4.57 3.05 0.00 ROOM_1_FLR_3_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
101 ROOM_2_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.53 0.00 ROOM_2_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
102 ROOM_2_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   39.02 39.02 39.02 180.00 0.00 4.57 8.53 0.00 ROOM_2_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
103 ROOM_2_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.03 78.03 78.03 0.00 90.00 78.03 1.00 0.00 ROOM_2_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
104 ROOM_3_MULT19_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   7.47 11.15 7.47 180.00 90.00 3.66 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
105 ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW Window ROOM_3_MULT19_FLR_3_WALL_SOUTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 3.68 3.68 3.68 180.00 90.00 3.02 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
106 ROOM_3_MULT19_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   11.15 11.15 11.15 0.00 90.00 3.66 3.05 0.00 ROOM_3_MULT19_FLR_3_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
107 ROOM_3_MULT19_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 90.00 90.00 6.71 3.05 0.00 ROOM_3_MULT19_FLR_3_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
108 ROOM_3_MULT19_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 270.00 90.00 6.71 3.05 0.00 ROOM_3_MULT19_FLR_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
109 ROOM_3_MULT19_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   24.52 24.52 24.52 0.00 180.00 3.66 6.71 0.00 ROOM_3_MULT19_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
110 ROOM_3_MULT19_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   24.52 24.52 24.52 180.00 0.00 3.66 6.71 0.00 ROOM_3_MULT19_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
111 ROOM_3_MULT19_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   49.05 49.05 49.05 0.00 90.00 49.05 1.00 0.00 ROOM_3_MULT19_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
112 ROOM_4_MULT19_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   7.47 11.15 7.47 0.00 90.00 3.66 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
113 ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW Window ROOM_4_MULT19_FLR_3_WALL_NORTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 3.68 3.68 3.68 0.00 90.00 3.02 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
114 ROOM_4_MULT19_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 90.00 90.00 6.71 3.05 0.00 ROOM_4_MULT19_FLR_3_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
115 ROOM_4_MULT19_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   11.15 11.15 11.15 180.00 90.00 3.66 3.05 0.00 ROOM_4_MULT19_FLR_3_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
116 ROOM_4_MULT19_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 270.00 90.00 6.71 3.05 0.00 ROOM_4_MULT19_FLR_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
117 ROOM_4_MULT19_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   24.53 24.53 24.53 0.00 180.00 3.66 6.71 0.00 ROOM_4_MULT19_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
118 ROOM_4_MULT19_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   24.53 24.53 24.53 180.00 0.00 3.66 6.71 0.00 ROOM_4_MULT19_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
119 ROOM_4_MULT19_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   49.06 49.06 49.06 0.00 90.00 49.06 1.00 0.00 ROOM_4_MULT19_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
120 ROOM_5_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   17.43 26.01 17.43 90.00 90.00 8.54 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
121 ROOM_5_FLR_3_WALL_EAST_WINDOW Window ROOM_5_FLR_3_WALL_EAST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 90.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
122 ROOM_5_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   9.34 13.94 9.34 180.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
123 ROOM_5_FLR_3_WALL_SOUTH_WINDOW Window ROOM_5_FLR_3_WALL_SOUTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 180.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
124 ROOM_5_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 0.00 90.00 4.57 3.05 0.00 ROOM_6_FLR_3_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
125 ROOM_5_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 270.00 90.00 8.54 3.05 0.00 CORRIDOR_FLR_3_WALL_3_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
126 ROOM_5_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.54 0.00 ROOM_5_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
127 ROOM_5_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   39.02 39.02 39.02 180.00 0.00 4.57 8.54 0.00 ROOM_5_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
128 ROOM_5_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.04 78.04 78.04 0.00 90.00 78.04 1.00 0.00 ROOM_5_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
129 ROOM_6_FLR_3_WALL_NORTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   9.34 13.94 9.34 0.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
130 ROOM_6_FLR_3_WALL_NORTH_WINDOW Window ROOM_6_FLR_3_WALL_NORTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 0.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
131 ROOM_6_FLR_3_WALL_EAST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.890 0.785   17.43 26.01 17.43 90.00 90.00 8.53 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
132 ROOM_6_FLR_3_WALL_EAST_WINDOW Window ROOM_6_FLR_3_WALL_EAST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 90.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
133 ROOM_6_FLR_3_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 180.00 90.00 4.57 3.05 0.00 ROOM_5_FLR_3_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
134 ROOM_6_FLR_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 270.00 90.00 8.53 3.05 0.00 CORRIDOR_FLR_3_WALL_4_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
135 ROOM_6_FLR_3_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.53 0.00 ROOM_6_FLR_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
136 ROOM_6_FLR_3_CEILING Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   39.02 39.02 39.02 180.00 0.00 4.57 8.53 0.00 ROOM_6_FLR_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
137 ROOM_6_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.03 78.03 78.03 0.00 90.00 78.03 1.00 0.00 ROOM_6_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
138 CORRIDOR_FLR_3_WALL_1_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.890 0.785   11.83 17.65 11.83 0.00 90.00 5.79 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
139 CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW Window CORRIDOR_FLR_3_WALL_1_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 5.82 5.82 5.82 0.00 90.00 4.78 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
140 CORRIDOR_FLR_3_WALL_2_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.890 0.785   4.35 6.50 4.35 0.00 90.00 2.13 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
141 CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW Window CORRIDOR_FLR_3_WALL_2_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 2.15 2.15 2.15 0.00 90.00 1.76 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
142 CORRIDOR_FLR_3_WALL_1_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.890 0.785   4.36 6.50 4.36 180.00 90.00 2.13 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
143 CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW Window CORRIDOR_FLR_3_WALL_1_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 2.15 2.15 2.15 180.00 90.00 1.76 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
144 CORRIDOR_FLR_3_WALL_2_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.890 0.785   11.83 17.65 11.83 180.00 90.00 5.79 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
145 CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW Window CORRIDOR_FLR_3_WALL_2_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 5.82 5.82 5.82 180.00 90.00 4.78 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
146 CORRIDOR_FLR_3_WALL_3_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   211.82 211.82 211.82 0.00 90.00 69.50 3.05 0.00 CORRIDOR_FLR_3_WALL_3_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
147 CORRIDOR_FLR_3_WALL_1_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 90.00 90.00 6.71 3.05 0.00 CORRIDOR_FLR_3_WALL_1_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
148 CORRIDOR_FLR_3_WALL_2_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 90.00 90.00 6.71 3.05 0.00 CORRIDOR_FLR_3_WALL_2_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
149 CORRIDOR_FLR_3_WALL_3_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.54 3.05 0.00 ROOM_5_FLR_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
150 CORRIDOR_FLR_3_WALL_4_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.53 3.05 0.00 ROOM_6_FLR_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
151 CORRIDOR_FLR_3_WALL_3_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   211.82 211.82 211.82 180.00 90.00 69.49 3.05 0.00 CORRIDOR_FLR_3_WALL_3_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
152 CORRIDOR_FLR_3_WALL_1_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 270.00 90.00 6.71 3.05 0.00 CORRIDOR_FLR_3_WALL_1_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
153 CORRIDOR_FLR_3_WALL_2_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 270.00 90.00 6.71 3.05 0.00 CORRIDOR_FLR_3_WALL_2_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
154 CORRIDOR_FLR_3_WALL_3_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 270.00 90.00 8.54 3.05 0.00 ROOM_1_FLR_3_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
155 CORRIDOR_FLR_3_WALL_4_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 270.00 90.00 8.53 3.05 0.00 ROOM_2_FLR_3_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
156 CORRIDOR_FLR_3_FLOOR_1 Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   74.32 74.32 74.32 180.00 180.00 8.62 8.62 0.00 CORRIDOR_FLR_3_FLOOR_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 6
157 CORRIDOR_FLR_3_FLOOR_2 Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   240.77 240.77 240.77 270.00 180.00 3.66 65.84 0.00 CORRIDOR_FLR_3_FLOOR_2 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
158 CORRIDOR_FLR_3_FLOOR_3 Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   74.32 74.32 74.32 90.00 180.00 8.62 8.62 0.00 CORRIDOR_FLR_3_FLOOR_3 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 6
159 CORRIDOR_FLR_3_CEILING_1 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   74.32 74.32 74.32 90.00 0.00 8.62 8.62 0.00 CORRIDOR_FLR_3_CEILING_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 6
160 CORRIDOR_FLR_3_CEILING_2 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   240.77 240.77 240.77 90.00 0.00 3.66 65.84 0.00 CORRIDOR_FLR_3_CEILING_2 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
161 CORRIDOR_FLR_3_CEILING_3 Roof   CTF - ConductionTransferFunction NONRES_FLOOR_CEILING 0.190 0.184   74.32 74.32 74.32 90.00 0.00 8.62 8.62 0.00 CORRIDOR_FLR_3_CEILING_3 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 6
162 CORRIDOR_FLR_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   778.81 778.81 778.81 0.00 90.00 778.81 1.00 0.00 CORRIDOR_FLR_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
163 ROOM_1_FLR_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.953 0.834   9.34 13.94 9.34 180.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
164 ROOM_1_FLR_6_WALL_SOUTH_WINDOW Window ROOM_1_FLR_6_WALL_SOUTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 180.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
165 ROOM_1_FLR_6_WALL_WEST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.953 0.834   17.43 26.01 17.43 270.00 90.00 8.54 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
166 ROOM_1_FLR_6_WALL_WEST_WINDOW Window ROOM_1_FLR_6_WALL_WEST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 270.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
167 ROOM_1_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 0.00 90.00 4.57 3.05 0.00 ROOM_2_FLR_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
168 ROOM_1_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.54 3.05 0.00 ROOM_1_FLR_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
169 ROOM_1_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.54 0.00 ROOM_1_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
170 ROOM_1_FLR_6_CEILING Roof   CTF - ConductionTransferFunction RES_ROOF 0.163 0.158   39.02 39.02 39.02 180.00 0.00 4.57 8.54 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
171 ROOM_1_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.04 78.04 78.04 0.00 90.00 78.04 1.00 0.00 ROOM_1_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
172 ROOM_2_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.953 0.834   9.34 13.94 9.34 0.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
173 ROOM_2_FLR_6_WALL_NORTH_WINDOW Window ROOM_2_FLR_6_WALL_NORTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 0.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
174 ROOM_2_FLR_6_WALL_WEST Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.953 0.834   17.43 26.01 17.43 270.00 90.00 8.53 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
175 ROOM_2_FLR_6_WALL_WEST_WINDOW Window ROOM_2_FLR_6_WALL_WEST Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 8.58 8.58 8.58 270.00 90.00 7.04 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
176 ROOM_2_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   26.01 26.01 26.01 90.00 90.00 8.53 3.05 0.00 ROOM_2_FLR_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
177 ROOM_2_FLR_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   13.94 13.94 13.94 180.00 90.00 4.57 3.05 0.00 ROOM_1_FLR_6_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
178 ROOM_2_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   39.02 39.02 39.02 0.00 180.00 4.57 8.53 0.00 ROOM_2_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
179 ROOM_2_FLR_6_CEILING Roof   CTF - ConductionTransferFunction RES_ROOF 0.163 0.158   39.02 39.02 39.02 180.00 0.00 4.57 8.53 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
180 ROOM_2_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   78.03 78.03 78.03 0.00 90.00 78.03 1.00 0.00 ROOM_2_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
181 ROOM_3_MULT9_FLR_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.953 0.834   13.70 20.44 13.70 180.00 90.00 6.71 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
182 ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW Window ROOM_3_MULT9_FLR_6_WALL_SOUTH Window5 Detailed Fenestration RESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 6.74 6.74 6.74 180.00 90.00 5.53 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
183 ROOM_3_MULT9_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 0.00 90.00 6.71 3.05 0.00 ROOM_3_MULT9_FLR_6_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
184 ROOM_3_MULT9_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   11.15 11.15 11.15 90.00 90.00 3.66 3.05 0.00 ROOM_3_MULT9_FLR_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
185 ROOM_3_MULT9_FLR_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   11.15 11.15 11.15 270.00 90.00 3.66 3.05 0.00 ROOM_3_MULT9_FLR_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
186 ROOM_3_MULT9_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   24.53 24.53 24.53 0.00 180.00 6.71 3.66 0.00 ROOM_3_MULT9_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
187 ROOM_3_MULT9_FLR_6_CEILING Roof   CTF - ConductionTransferFunction RES_ROOF 0.163 0.158   24.53 24.53 24.53 180.00 0.00 6.71 3.66 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
188 ROOM_3_MULT9_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   49.06 49.06 49.06 0.00 90.00 49.06 1.00 0.00 ROOM_3_MULT9_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
189 BANQUET_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   65.36 97.55 65.36 0.00 90.00 32.00 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
190 BANQUET_FLR_6_WALL_NORTH_WINDOW Window BANQUET_FLR_6_WALL_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 32.19 32.19 32.19 0.00 90.00 26.40 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
191 BANQUET_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 90.00 90.00 10.36 3.05 0.00 CORRIDOR_FLR_6_WALL_3_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
192 BANQUET_FLR_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   97.55 97.55 97.55 180.00 90.00 32.00 3.05 0.00 CORRIDOR_FLR_6_WALL_3_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
193 BANQUET_FLR_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 270.00 90.00 10.36 3.05 0.00 CORRIDOR_FLR_6_WALL_1_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
194 BANQUET_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   331.66 331.66 331.66 0.00 180.00 32.00 10.36 0.00 BANQUET_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
195 BANQUET_FLR_6_CEILING Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   331.66 331.66 331.66 180.00 0.00 32.00 10.36 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
196 BANQUET_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   663.31 663.31 663.31 0.00 90.00 663.31 1.00 0.00 BANQUET_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
197 DINING_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   65.36 97.55 65.36 0.00 90.00 32.00 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
198 DINING_FLR_6_WALL_NORTH_WINDOW Window DINING_FLR_6_WALL_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 32.19 32.19 32.19 0.00 90.00 26.40 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
199 DINING_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 90.00 90.00 10.36 3.05 0.00 KITCHEN_FLR_6_WALL_2_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
200 DINING_FLR_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   97.55 97.55 97.55 180.00 90.00 32.00 3.05 0.00 DINING_FLR_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
201 DINING_FLR_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 270.00 90.00 10.36 3.05 0.00 CORRIDOR_FLR_6_WALL_2_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
202 DINING_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   331.66 331.66 331.66 0.00 180.00 32.00 10.36 0.00 DINING_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
203 DINING_FLR_6_CEILING Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   331.66 331.66 331.66 180.00 0.00 32.00 10.36 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
204 DINING_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   663.31 663.31 663.31 0.00 90.00 663.31 1.00 0.00 DINING_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
205 KITCHEN_FLR_6_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   16.77 21.37 16.77 0.00 90.00 7.01 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
206 KITCHEN_FLR_6_WALL_NORTH_WINDOW Window KITCHEN_FLR_6_WALL_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 0.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
207 KITCHEN_FLR_6_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   34.86 52.03 34.86 90.00 90.00 17.07 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
208 KITCHEN_FLR_6_WALL_EAST_WINDOW Window KITCHEN_FLR_6_WALL_EAST Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 17.17 17.17 17.17 90.00 90.00 14.08 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
209 KITCHEN_FLR_6_WALL_1_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   9.34 13.94 9.34 180.00 90.00 4.57 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
210 KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW Window KITCHEN_FLR_6_WALL_1_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 4.60 4.60 4.60 180.00 90.00 3.77 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
211 KITCHEN_FLR_6_WALL_2_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   7.43 7.43 7.43 180.00 90.00 2.44 3.05 0.00 KITCHEN_FLR_6_WALL_2_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
212 KITCHEN_FLR_6_WALL_1_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 270.00 90.00 6.71 3.05 0.00 CORRIDOR_FLR_6_WALL_3_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
213 KITCHEN_FLR_6_WALL_2_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 270.00 90.00 10.36 3.05 0.00 DINING_FLR_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
214 KITCHEN_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   103.30 103.30 103.30 180.00 180.00 10.16 10.16 0.00 KITCHEN_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 6
215 KITCHEN_FLR_6_CEILING Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   103.30 103.30 103.30 270.00 0.00 10.16 10.16 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 6
216 KITCHEN_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   206.61 206.61 206.61 0.00 90.00 206.61 1.00 0.00 KITCHEN_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
217 CORRIDOR_FLR_6_WALL_1_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   11.83 17.65 11.83 0.00 90.00 5.79 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
218 CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW Window CORRIDOR_FLR_6_WALL_1_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 5.82 5.82 5.82 0.00 90.00 4.78 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
219 CORRIDOR_FLR_6_WALL_2_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   10.58 15.79 10.58 0.00 90.00 5.18 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
220 CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW Window CORRIDOR_FLR_6_WALL_2_NORTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 5.21 5.21 5.21 0.00 90.00 4.27 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
221 CORRIDOR_FLR_6_WALL_2_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 0.953 0.834   34.86 52.03 34.86 180.00 90.00 17.07 3.05 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
222 CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW Window CORRIDOR_FLR_6_WALL_2_SOUTH Window5 Detailed Fenestration NONRESWINDOW_U_0.2964_SHGC_0.45 N/A 1.683 No 17.17 17.17 17.17 180.00 90.00 14.08 1.22 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
223 CORRIDOR_FLR_6_WALL_3_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   97.55 97.55 97.55 0.00 90.00 32.00 3.05 0.00 BANQUET_FLR_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
224 CORRIDOR_FLR_6_WALL_4_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   104.98 104.98 104.98 0.00 90.00 34.44 3.05 0.00 CORRIDOR_FLR_6_WALL_4_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
225 CORRIDOR_FLR_6_WALL_1_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   183.95 183.95 183.95 180.00 90.00 60.35 3.05 0.00 CORRIDOR_FLR_6_WALL_1_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
226 CORRIDOR_FLR_6_WALL_1_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   11.15 11.15 11.15 270.00 90.00 3.66 3.05 0.00 CORRIDOR_FLR_6_WALL_1_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
227 CORRIDOR_FLR_6_WALL_2_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   40.88 40.88 40.88 270.00 90.00 13.41 3.05 0.00 CORRIDOR_FLR_6_WALL_2_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
228 CORRIDOR_FLR_6_WALL_3_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 270.00 90.00 10.36 3.05 0.00 BANQUET_FLR_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
229 CORRIDOR_FLR_6_WALL_1_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 90.00 90.00 10.36 3.05 0.00 BANQUET_FLR_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
230 CORRIDOR_FLR_6_WALL_2_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   31.59 31.59 31.59 90.00 90.00 10.36 3.05 0.00 DINING_FLR_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
231 CORRIDOR_FLR_6_WALL_3_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   20.44 20.44 20.44 90.00 90.00 6.71 3.05 0.00 KITCHEN_FLR_6_WALL_1_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
232 CORRIDOR_FLR_6_FLOOR Floor   CTF - ConductionTransferFunction NONRES_FLOOR 0.190 0.182   412.12 412.12 412.12 180.00 180.00 20.30 20.30 0.00 CORRIDOR_FLR_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 12
233 CORRIDOR_FLR_6_CEILING_1 Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   244.71 244.71 244.71 90.00 0.00 15.64 15.64 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 8
234 CORRIDOR_FLR_6_CEILING_2 Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.163 0.158   167.42 167.42 167.42 270.00 0.00 12.94 12.94 0.00 ExternalEnvironment DOE-2 ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 6
235 CORRIDOR_FLR_6_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   824.25 824.25 824.25 0.00 90.00 824.25 1.00 0.00 CORRIDOR_FLR_6_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEARS DAY Holiday InputFile 01/01 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 BASEMENT RunPeriod: RUNPERIOD 1 1.8287102771E-002 2.3088303468E-002 Pass Pass 2.6527269458E-003 4.3214369395E-003 Pass Pass
2 RETAIL_1_FLR_1 RunPeriod: RUNPERIOD 1 2.4067694404E-003 1.7235393157E-003 Pass Pass 1.4123289866E-002 2.7154489869E-002 Pass Pass
3 RETAIL_2_FLR_1 RunPeriod: RUNPERIOD 1 2.4226012103E-003 5.4820320224E-003 Pass Pass 0.1176400233 0.6275579502 Pass Pass
4 MECH_FLR_1 RunPeriod: RUNPERIOD 1 6.0665225015E-004 4.4402206555E-004 Pass Pass 0.3233813707 2.6909619282 Pass Pass
5 STORAGE_FLR_1 RunPeriod: RUNPERIOD 1 5.1023270505E-004 4.2239748459E-004 Pass Pass 1.1338993672E-002 1.8916849380E-002 Pass Pass
6 LAUNDRY_FLR_1 RunPeriod: RUNPERIOD 1 6.6183268670E-002 0.2194940237 Pass Pass 1.9705813601E-002 5.5777716778E-002 Pass Pass
7 CAFE_FLR_1 RunPeriod: RUNPERIOD 1 2.5341534407E-003 1.8818578169E-003 Pass Pass 8.1345982353E-002 0.2281938400 Pass Pass
8 LOBBY_FLR_1 RunPeriod: RUNPERIOD 1 1.0233354094E-002 2.2980226522E-002 Pass Pass 5.7651102088E-002 0.1992350632 Pass Pass
9 ROOM_1_FLR_3 RunPeriod: RUNPERIOD 1 9.2662126950E-002 0.3773960319 Pass Pass 7.9787461222E-002 0.2673827187 Pass Pass
10 ROOM_2_FLR_3 RunPeriod: RUNPERIOD 1 9.2624901205E-002 0.3765499519 Pass Pass 7.9154342128E-002 0.2660656377 Pass Pass
11 ROOM_3_MULT19_FLR_3 RunPeriod: RUNPERIOD 1 5.0618894267E-005 1.0533160068E-004 Pass Pass 1.7256580118E-002 3.9663765697E-002 Pass Pass
12 ROOM_4_MULT19_FLR_3 RunPeriod: RUNPERIOD 1 8.2970203911E-002 0.2764497163 Pass Pass 0.2233169363 0.7987421368 Pass Pass
13 ROOM_5_FLR_3 RunPeriod: RUNPERIOD 1 9.2672561871E-002 0.3768730971 Pass Pass 8.0013071996E-002 0.2676556491 Pass Pass
14 ROOM_6_FLR_3 RunPeriod: RUNPERIOD 1 9.2680514500E-002 0.3760205743 Pass Pass 7.9348056908E-002 0.2664477766 Pass Pass
15 CORRIDOR_FLR_3 RunPeriod: RUNPERIOD 1 4.4016259739E-004 3.5115395764E-004 Pass Pass 6.4756343968E-002 0.2196761392 Pass Pass
16 ROOM_1_FLR_6 RunPeriod: RUNPERIOD 1 9.2759505697E-002 0.3886594443 Pass Pass 7.2503257130E-002 0.2505524188 Pass Pass
17 ROOM_2_FLR_6 RunPeriod: RUNPERIOD 1 9.2673977081E-002 0.3881297657 Pass Pass 7.1244680997E-002 0.2468568173 Pass Pass
18 ROOM_3_MULT9_FLR_6 RunPeriod: RUNPERIOD 1 9.2662949399E-002 0.3753975531 Pass Pass 9.3187478482E-002 0.2984149936 Pass Pass
19 BANQUET_FLR_6 RunPeriod: RUNPERIOD 1 5.5024398894E-002 0.1033936549 Pass Pass 9.3531667122E-003 2.2168569555E-002 Pass Pass
20 DINING_FLR_6 RunPeriod: RUNPERIOD 1 4.7015369286E-002 8.3716535580E-002 Pass Pass 1.0164246280E-002 2.9984332712E-002 Pass Pass
21 KITCHEN_FLR_6 RunPeriod: RUNPERIOD 1 3.6522466370E-002 0.1085195639 Pass Pass 2.3115516302E-002 4.2757355639E-002 Pass Pass
22 CORRIDOR_FLR_6 RunPeriod: RUNPERIOD 1 8.3639737579E-004 6.2811810827E-004 Pass Pass 1.5661625079E-002 2.3770427741E-002 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 2538.89 261.45 3103.30 13112.68 2780.76 21797.08



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB -41.90 0.00 -41.90 Wetbulb [C] 0.30 20.00
FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 27.40 10.20 16.10 Wetbulb [C] 3.10 180.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 0.00 0      
Feb 0.00 0      
Mar 0.00 0      
Apr 0.00 0      
May 0.00 0      
Jun 0.00 0      
Jul 0.00 0      
Aug 0.00 0      
Sep 0.00 0      
Oct 0.00 0      
Nov 0.00 0      
Dec 0.00 0      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
BASEMENT_WALL_NORTH BASEMENT_WALL_NORTH_CFACTOR 1.00 0.340 0.354 211.13 211.13 0.00 90.00 N
BASEMENT_WALL_EAST BASEMENT_WALL_EAST_CFACTOR 1.00 0.340 0.354 55.76 55.76 90.00 90.00 E
BASEMENT_WALL_SOUTH BASEMENT_WALL_SOUTH_CFACTOR 1.00 0.340 0.354 211.13 211.13 180.00 90.00 S
BASEMENT_WALL_WEST BASEMENT_WALL_WEST_CFACTOR 1.00 0.340 0.354 55.76 55.76 270.00 90.00 W
RETAIL_1_FLR_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 45.89 22.63 180.00 90.00 S
RETAIL_1_FLR_1_WALL_WEST NONRES_EXT_WALL_GRD 0.30 0.568 0.620 22.95 22.95 270.00 90.00 W
RETAIL_1_FLR_1_CEILING NONRES_ROOF 0.23 0.159 0.163 67.07 67.07 180.00 0.00  
RETAIL_2_FLR_1_WALL_WEST NONRES_EXT_WALL_GRD 0.30 0.568 0.620 26.57 24.62 270.00 90.00 W
MECH_FLR_1_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 62.80 62.80 0.00 90.00 N
STORAGE_FLR_1_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 36.23 28.80 0.00 90.00 N
LAUNDRY_FLR_1_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 18.12 18.12 0.00 90.00 N
LAUNDRY_FLR_1_WALL_EAST NONRES_EXT_WALL_GRD 0.30 0.568 0.620 67.63 65.68 90.00 90.00 E
CAFE_FLR_1_WALL_EAST NONRES_EXT_WALL_GRD 0.30 0.568 0.620 22.95 21.00 90.00 90.00 E
CAFE_FLR_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 129.23 63.73 180.00 90.00 S
CAFE_FLR_1_CEILING NONRES_ROOF 0.23 0.159 0.163 188.86 188.86 180.00 0.00  
LOBBY_FLR_1_WALL_1_NORTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 213.77 209.87 0.00 90.00 N
LOBBY_FLR_1_WALL_2_NORTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 12.08 12.08 0.00 90.00 N
LOBBY_FLR_1_WALL_1_SOUTH NONRES_EXT_WALL_GRD 0.30 0.568 0.620 167.88 82.79 180.00 90.00 S
LOBBY_FLR_1_WALL_1_WEST NONRES_EXT_WALL_GRD 0.30 0.568 0.620 41.06 41.06 270.00 90.00 W
LOBBY_FLR_1_CEILING_2 NONRES_ROOF 0.23 0.159 0.163 245.35 245.35 180.00 0.00  
ROOM_1_FLR_3_WALL_SOUTH RES_EXT_WALL_MID 0.30 0.785 0.890 55.74 37.35 180.00 90.00 S
ROOM_1_FLR_3_WALL_WEST RES_EXT_WALL_MID 0.30 0.785 0.890 104.06 69.72 270.00 90.00 W
ROOM_2_FLR_3_WALL_NORTH RES_EXT_WALL_MID 0.30 0.785 0.890 55.74 37.35 0.00 90.00 N
ROOM_2_FLR_3_WALL_WEST RES_EXT_WALL_MID 0.30 0.785 0.890 104.05 69.71 270.00 90.00 W
ROOM_3_MULT19_FLR_3_WALL_SOUTH RES_EXT_WALL_MID 0.30 0.785 0.890 847.14 567.58 180.00 90.00 S
ROOM_4_MULT19_FLR_3_WALL_NORTH RES_EXT_WALL_MID 0.30 0.785 0.890 847.37 567.71 0.00 90.00 N
ROOM_5_FLR_3_WALL_EAST RES_EXT_WALL_MID 0.30 0.785 0.890 104.06 69.72 90.00 90.00 E
ROOM_5_FLR_3_WALL_SOUTH RES_EXT_WALL_MID 0.30 0.785 0.890 55.74 37.35 180.00 90.00 S
ROOM_6_FLR_3_WALL_NORTH RES_EXT_WALL_MID 0.30 0.785 0.890 55.74 37.35 0.00 90.00 N
ROOM_6_FLR_3_WALL_EAST RES_EXT_WALL_MID 0.30 0.785 0.890 104.05 69.71 90.00 90.00 E
CORRIDOR_FLR_3_WALL_1_NORTH NONRES_EXT_WALL_MID 0.30 0.785 0.890 70.60 47.31 0.00 90.00 N
CORRIDOR_FLR_3_WALL_2_NORTH NONRES_EXT_WALL_MID 0.30 0.785 0.890 26.01 17.42 0.00 90.00 N
CORRIDOR_FLR_3_WALL_1_SOUTH NONRES_EXT_WALL_MID 0.30 0.785 0.890 26.02 17.43 180.00 90.00 S
CORRIDOR_FLR_3_WALL_2_SOUTH NONRES_EXT_WALL_MID 0.30 0.785 0.890 70.60 47.31 180.00 90.00 S
ROOM_1_FLR_6_WALL_SOUTH RES_EXT_WALL_TOP 0.30 0.834 0.953 13.94 9.34 180.00 90.00 S
ROOM_1_FLR_6_WALL_WEST RES_EXT_WALL_TOP 0.30 0.834 0.953 26.01 17.43 270.00 90.00 W
ROOM_1_FLR_6_CEILING RES_ROOF 0.23 0.159 0.163 39.02 39.02 180.00 0.00  
ROOM_2_FLR_6_WALL_NORTH RES_EXT_WALL_TOP 0.30 0.834 0.953 13.94 9.34 0.00 90.00 N
ROOM_2_FLR_6_WALL_WEST RES_EXT_WALL_TOP 0.30 0.834 0.953 26.01 17.43 270.00 90.00 W
ROOM_2_FLR_6_CEILING RES_ROOF 0.23 0.159 0.163 39.02 39.02 180.00 0.00  
ROOM_3_MULT9_FLR_6_WALL_SOUTH RES_EXT_WALL_TOP 0.30 0.834 0.953 183.96 123.26 180.00 90.00 S
ROOM_3_MULT9_FLR_6_CEILING RES_ROOF 0.23 0.159 0.163 220.77 220.77 180.00 0.00  
BANQUET_FLR_6_WALL_NORTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 97.55 65.36 0.00 90.00 N
BANQUET_FLR_6_CEILING NONRES_ROOF 0.23 0.159 0.163 331.66 331.66 180.00 0.00  
DINING_FLR_6_WALL_NORTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 97.55 65.36 0.00 90.00 N
DINING_FLR_6_CEILING NONRES_ROOF 0.23 0.159 0.163 331.66 331.66 180.00 0.00  
KITCHEN_FLR_6_WALL_NORTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 21.37 16.77 0.00 90.00 N
KITCHEN_FLR_6_WALL_EAST NONRES_EXT_WALL_TOP 0.30 0.834 0.953 52.03 34.86 90.00 90.00 E
KITCHEN_FLR_6_WALL_1_SOUTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 13.94 9.34 180.00 90.00 S
KITCHEN_FLR_6_CEILING NONRES_ROOF 0.23 0.159 0.163 103.30 103.30 270.00 0.00  
CORRIDOR_FLR_6_WALL_1_NORTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 17.65 11.83 0.00 90.00 N
CORRIDOR_FLR_6_WALL_2_NORTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 15.79 10.58 0.00 90.00 N
CORRIDOR_FLR_6_WALL_2_SOUTH NONRES_EXT_WALL_TOP 0.30 0.834 0.953 52.03 34.86 180.00 90.00 S
CORRIDOR_FLR_6_CEILING_1 NONRES_ROOF 0.23 0.159 0.163 244.71 244.71 90.00 0.00  
CORRIDOR_FLR_6_CEILING_2 NONRES_ROOF 0.23 0.159 0.163 167.42 167.42 270.00 0.00  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
BASEMENT_FLOOR BASEMENT_FLOOR 0.30 1.441 2.705 1978.83 1978.83 0.00 180.00  
BASEMENT_CEILING_1 NONRES_FLOOR_CEILING 0.30 0.181 0.190 67.07 67.07 180.00 0.00  
BASEMENT_CEILING_2 NONRES_FLOOR_CEILING 0.30 0.181 0.190 77.67 77.67 180.00 0.00  
BASEMENT_CEILING_3 NONRES_FLOOR_CEILING 0.30 0.181 0.190 164.24 164.24 180.00 0.00  
BASEMENT_CEILING_4 NONRES_FLOOR_CEILING 0.30 0.181 0.190 94.76 94.76 180.00 0.00  
BASEMENT_CEILING_5 NONRES_FLOOR_CEILING 0.30 0.181 0.190 78.04 78.04 180.00 0.00  
BASEMENT_CEILING_6 NONRES_FLOOR_CEILING 0.30 0.181 0.190 188.86 188.86 180.00 0.00  
BASEMENT_CEILING_7 NONRES_FLOOR_CEILING 0.30 0.181 0.190 1088.56 1088.56 180.00 0.00  
BASEMENT_CEILING_8 NONRES_FLOOR_CEILING 0.30 0.181 0.190 219.63 219.63 90.00 0.00  
RETAIL_1_FLR_1_WALL_NORTH INT_WALL 0.30 2.511 6.299 45.89 45.89 0.00 90.00 N
RETAIL_1_FLR_1_WALL_EAST INT_WALL 0.30 2.511 6.299 22.95 22.95 90.00 90.00 E
RETAIL_1_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 67.07 67.07 0.00 180.00  
RETAIL_2_FLR_1_WALL_SOUTH INT_WALL 0.30 2.511 6.299 45.89 45.89 180.00 90.00 S
RETAIL_2_FLR_1_WALL_NORTH INT_WALL 0.30 2.511 6.299 45.89 45.89 0.00 90.00 N
RETAIL_2_FLR_1_WALL_EAST INT_WALL 0.30 2.511 6.299 26.57 26.57 90.00 90.00 E
RETAIL_2_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 77.67 77.67 0.00 180.00  
RETAIL_2_FLR_1_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 77.67 77.67 180.00 0.00  
MECH_FLR_1_WALL_EAST INT_WALL 0.30 2.511 6.299 41.06 41.06 90.00 90.00 E
MECH_FLR_1_WALL_SOUTH INT_WALL 0.30 2.511 6.299 62.80 62.80 180.00 90.00 S
MECH_FLR_1_WALL_WEST INT_WALL 0.30 2.511 6.299 41.06 41.06 270.00 90.00 W
MECH_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 164.24 164.24 0.00 180.00  
MECH_FLR_1_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 164.24 164.24 180.00 0.00  
STORAGE_FLR_1_WALL_EAST INT_WALL 0.30 2.511 6.299 41.06 41.06 90.00 90.00 E
STORAGE_FLR_1_WALL_SOUTH INT_WALL 0.30 2.511 6.299 36.23 36.23 180.00 90.00 S
STORAGE_FLR_1_WALL_WEST INT_WALL 0.30 2.511 6.299 41.06 41.06 270.00 90.00 W
STORAGE_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 94.76 94.76 0.00 180.00  
STORAGE_FLR_1_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 94.76 94.76 180.00 0.00  
LAUNDRY_FLR_1_WALL_SOUTH INT_WALL 0.30 2.511 6.299 18.12 18.12 180.00 90.00 S
LAUNDRY_FLR_1_WALL_WEST INT_WALL 0.30 2.511 6.299 67.63 67.63 270.00 90.00 W
LAUNDRY_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 78.04 78.04 0.00 180.00  
LAUNDRY_FLR_1_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 78.04 78.04 180.00 0.00  
CAFE_FLR_1_WALL_1_NORTH INT_WALL 0.30 2.511 6.299 111.11 111.11 0.00 90.00 N
CAFE_FLR_1_WALL_2_NORTH INT_WALL 0.30 2.511 6.299 18.12 18.12 0.00 90.00 N
CAFE_FLR_1_WALL_WEST INT_WALL 0.30 2.511 6.299 22.95 22.95 270.00 90.00 W
CAFE_FLR_1_FLOOR NONRES_FLOOR 0.30 0.181 0.190 188.86 188.86 0.00 180.00  
LOBBY_FLR_1_WALL_2_SOUTH INT_WALL 0.30 2.511 6.299 45.89 45.89 180.00 90.00 S
LOBBY_FLR_1_WALL_3_SOUTH INT_WALL 0.30 2.511 6.299 111.11 111.11 180.00 90.00 S
LOBBY_FLR_1_WALL_2_WEST INT_WALL 0.30 2.511 6.299 22.95 22.95 270.00 90.00 W
LOBBY_FLR_1_WALL_3_WEST INT_WALL 0.30 2.511 6.299 26.57 26.57 270.00 90.00 W
LOBBY_FLR_1_WALL_4_WEST INT_WALL 0.30 2.511 6.299 41.06 41.06 270.00 90.00 W
LOBBY_FLR_1_WALL_3_NORTH INT_WALL 0.30 2.511 6.299 62.80 62.80 0.00 90.00 N
LOBBY_FLR_1_WALL_4_NORTH INT_WALL 0.30 2.511 6.299 36.23 36.23 0.00 90.00 N
LOBBY_FLR_1_WALL_1_EAST INT_WALL 0.30 2.511 6.299 41.06 41.06 90.00 90.00 E
LOBBY_FLR_1_WALL_2_EAST INT_WALL 0.30 2.511 6.299 22.95 22.95 90.00 90.00 E
LOBBY_FLR_1_WALL_3_EAST INT_WALL 0.30 2.511 6.299 67.63 67.63 90.00 90.00 E
LOBBY_FLR_1_FLOOR_1 NONRES_FLOOR 0.30 0.181 0.190 1088.56 1088.56 180.00 180.00  
LOBBY_FLR_1_FLOOR_2 NONRES_FLOOR 0.30 0.181 0.190 219.63 219.63 90.00 180.00  
LOBBY_FLR_1_CEILING_1 NONRES_FLOOR_CEILING 0.30 0.183 0.190 1062.83 1062.83 270.00 0.00  
ROOM_1_FLR_3_WALL_NORTH INT_WALL 0.30 2.511 6.299 55.74 55.74 0.00 90.00 N
ROOM_1_FLR_3_WALL_EAST INT_WALL 0.30 2.511 6.299 104.06 104.06 90.00 90.00 E
ROOM_1_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 156.09 156.09 0.00 180.00  
ROOM_1_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 156.09 156.09 180.00 0.00  
ROOM_2_FLR_3_WALL_EAST INT_WALL 0.30 2.511 6.299 104.05 104.05 90.00 90.00 E
ROOM_2_FLR_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 55.74 55.74 180.00 90.00 S
ROOM_2_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 156.07 156.07 0.00 180.00  
ROOM_2_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 156.07 156.07 180.00 0.00  
ROOM_3_MULT19_FLR_3_WALL_NORTH INT_WALL 0.30 2.511 6.299 847.14 847.14 0.00 90.00 N
ROOM_3_MULT19_FLR_3_WALL_EAST INT_WALL 0.30 2.511 6.299 1553.43 1553.43 90.00 90.00 E
ROOM_3_MULT19_FLR_3_WALL_WEST INT_WALL 0.30 2.511 6.299 1553.43 1553.43 270.00 90.00 W
ROOM_3_MULT19_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 1863.81 1863.81 0.00 180.00  
ROOM_3_MULT19_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 1863.81 1863.81 180.00 0.00  
ROOM_4_MULT19_FLR_3_WALL_EAST INT_WALL 0.30 2.511 6.299 1553.43 1553.43 90.00 90.00 E
ROOM_4_MULT19_FLR_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 847.37 847.37 180.00 90.00 S
ROOM_4_MULT19_FLR_3_WALL_WEST INT_WALL 0.30 2.511 6.299 1553.43 1553.43 270.00 90.00 W
ROOM_4_MULT19_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 1864.32 1864.32 0.00 180.00  
ROOM_4_MULT19_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 1864.32 1864.32 180.00 0.00  
ROOM_5_FLR_3_WALL_NORTH INT_WALL 0.30 2.511 6.299 55.74 55.74 0.00 90.00 N
ROOM_5_FLR_3_WALL_WEST INT_WALL 0.30 2.511 6.299 104.06 104.06 270.00 90.00 W
ROOM_5_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 156.09 156.09 0.00 180.00  
ROOM_5_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 156.09 156.09 180.00 0.00  
ROOM_6_FLR_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 55.74 55.74 180.00 90.00 S
ROOM_6_FLR_3_WALL_WEST INT_WALL 0.30 2.511 6.299 104.05 104.05 270.00 90.00 W
ROOM_6_FLR_3_FLOOR NONRES_FLOOR 0.30 0.179 0.190 156.07 156.07 0.00 180.00  
ROOM_6_FLR_3_CEILING NONRES_FLOOR_CEILING 0.30 0.183 0.190 156.07 156.07 180.00 0.00  
CORRIDOR_FLR_3_WALL_3_NORTH INT_WALL 0.30 2.511 6.299 847.28 847.28 0.00 90.00 N
CORRIDOR_FLR_3_WALL_1_EAST INT_WALL 0.30 2.511 6.299 81.76 81.76 90.00 90.00 E
CORRIDOR_FLR_3_WALL_2_EAST INT_WALL 0.30 2.511 6.299 81.76 81.76 90.00 90.00 E
CORRIDOR_FLR_3_WALL_3_EAST INT_WALL 0.30 2.511 6.299 104.06 104.06 90.00 90.00 E
CORRIDOR_FLR_3_WALL_4_EAST INT_WALL 0.30 2.511 6.299 104.05 104.05 90.00 90.00 E
CORRIDOR_FLR_3_WALL_3_SOUTH INT_WALL 0.30 2.511 6.299 847.27 847.27 180.00 90.00 S
CORRIDOR_FLR_3_WALL_1_WEST INT_WALL 0.30 2.511 6.299 81.76 81.76 270.00 90.00 W
CORRIDOR_FLR_3_WALL_2_WEST INT_WALL 0.30 2.511 6.299 81.76 81.76 270.00 90.00 W
CORRIDOR_FLR_3_WALL_3_WEST INT_WALL 0.30 2.511 6.299 104.06 104.06 270.00 90.00 W
CORRIDOR_FLR_3_WALL_4_WEST INT_WALL 0.30 2.511 6.299 104.05 104.05 270.00 90.00 W
CORRIDOR_FLR_3_FLOOR_1 NONRES_FLOOR 0.30 0.179 0.190 297.29 297.29 180.00 180.00  
CORRIDOR_FLR_3_FLOOR_2 NONRES_FLOOR 0.30 0.179 0.190 963.06 963.06 270.00 180.00  
CORRIDOR_FLR_3_FLOOR_3 NONRES_FLOOR 0.30 0.179 0.190 297.26 297.26 90.00 180.00  
CORRIDOR_FLR_3_CEILING_1 NONRES_FLOOR_CEILING 0.30 0.183 0.190 297.29 297.29 90.00 0.00  
CORRIDOR_FLR_3_CEILING_2 NONRES_FLOOR_CEILING 0.30 0.183 0.190 963.06 963.06 90.00 0.00  
CORRIDOR_FLR_3_CEILING_3 NONRES_FLOOR_CEILING 0.30 0.183 0.190 297.26 297.26 90.00 0.00  
ROOM_1_FLR_6_WALL_NORTH INT_WALL 0.30 2.511 6.299 13.94 13.94 0.00 90.00 N
ROOM_1_FLR_6_WALL_EAST INT_WALL 0.30 2.511 6.299 26.01 26.01 90.00 90.00 E
ROOM_1_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 39.02 39.02 0.00 180.00  
ROOM_2_FLR_6_WALL_EAST INT_WALL 0.30 2.511 6.299 26.01 26.01 90.00 90.00 E
ROOM_2_FLR_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 13.94 13.94 180.00 90.00 S
ROOM_2_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 39.02 39.02 0.00 180.00  
ROOM_3_MULT9_FLR_6_WALL_NORTH INT_WALL 0.30 2.511 6.299 183.96 183.96 0.00 90.00 N
ROOM_3_MULT9_FLR_6_WALL_EAST INT_WALL 0.30 2.511 6.299 100.35 100.35 90.00 90.00 E
ROOM_3_MULT9_FLR_6_WALL_WEST INT_WALL 0.30 2.511 6.299 100.35 100.35 270.00 90.00 W
ROOM_3_MULT9_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 220.77 220.77 0.00 180.00  
BANQUET_FLR_6_WALL_EAST INT_WALL 0.30 2.511 6.299 31.59 31.59 90.00 90.00 E
BANQUET_FLR_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 97.55 97.55 180.00 90.00 S
BANQUET_FLR_6_WALL_WEST INT_WALL 0.30 2.511 6.299 31.59 31.59 270.00 90.00 W
BANQUET_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 331.66 331.66 0.00 180.00  
DINING_FLR_6_WALL_EAST INT_WALL 0.30 2.511 6.299 31.59 31.59 90.00 90.00 E
DINING_FLR_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 97.55 97.55 180.00 90.00 S
DINING_FLR_6_WALL_WEST INT_WALL 0.30 2.511 6.299 31.59 31.59 270.00 90.00 W
DINING_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 331.66 331.66 0.00 180.00  
KITCHEN_FLR_6_WALL_2_SOUTH INT_WALL 0.30 2.511 6.299 7.43 7.43 180.00 90.00 S
KITCHEN_FLR_6_WALL_1_WEST INT_WALL 0.30 2.511 6.299 20.44 20.44 270.00 90.00 W
KITCHEN_FLR_6_WALL_2_WEST INT_WALL 0.30 2.511 6.299 31.59 31.59 270.00 90.00 W
KITCHEN_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 103.30 103.30 180.00 180.00  
CORRIDOR_FLR_6_WALL_3_NORTH INT_WALL 0.30 2.511 6.299 97.55 97.55 0.00 90.00 N
CORRIDOR_FLR_6_WALL_4_NORTH INT_WALL 0.30 2.511 6.299 104.98 104.98 0.00 90.00 N
CORRIDOR_FLR_6_WALL_1_SOUTH INT_WALL 0.30 2.511 6.299 183.95 183.95 180.00 90.00 S
CORRIDOR_FLR_6_WALL_1_WEST INT_WALL 0.30 2.511 6.299 11.15 11.15 270.00 90.00 W
CORRIDOR_FLR_6_WALL_2_WEST INT_WALL 0.30 2.511 6.299 40.88 40.88 270.00 90.00 W
CORRIDOR_FLR_6_WALL_3_WEST INT_WALL 0.30 2.511 6.299 31.59 31.59 270.00 90.00 W
CORRIDOR_FLR_6_WALL_1_EAST INT_WALL 0.30 2.511 6.299 31.59 31.59 90.00 90.00 E
CORRIDOR_FLR_6_WALL_2_EAST INT_WALL 0.30 2.511 6.299 31.59 31.59 90.00 90.00 E
CORRIDOR_FLR_6_WALL_3_EAST INT_WALL 0.30 2.511 6.299 20.44 20.44 90.00 90.00 E
CORRIDOR_FLR_6_FLOOR NONRES_FLOOR 0.30 0.179 0.190 412.12 412.12 180.00 180.00  
BASEMENT_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 3957.66   0.00 90.00 N
RETAIL_1_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.14   0.00 90.00 N
RETAIL_2_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 155.34   0.00 90.00 N
MECH_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 328.49   0.00 90.00 N
STORAGE_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 189.52   0.00 90.00 N
LAUNDRY_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 156.08   0.00 90.00 N
CAFE_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 377.72   0.00 90.00 N
LOBBY_FLR_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 2616.37   0.00 90.00 N
ROOM_1_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 312.18   0.00 90.00 N
ROOM_2_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 312.14   0.00 90.00 N
ROOM_3_MULT19_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 3727.63   0.00 90.00 N
ROOM_4_MULT19_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 3728.64   0.00 90.00 N
ROOM_5_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 312.18   0.00 90.00 N
ROOM_6_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 312.14   0.00 90.00 N
CORRIDOR_FLR_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 3115.24   0.00 90.00 N
ROOM_1_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 78.04   0.00 90.00 N
ROOM_2_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 78.03   0.00 90.00 N
ROOM_3_MULT9_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 441.55   0.00 90.00 N
BANQUET_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 663.31   0.00 90.00 N
DINING_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 663.31   0.00 90.00 N
KITCHEN_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 206.61   0.00 90.00 N
CORRIDOR_FLR_6_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 824.25   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   23.26 0.00 0.00 23.26 23.26 1.683 0.451 0.452             No RETAIL_1_FLR_1_WALL_SOUTH 180.00 90.00 S
CAFE_FLR_1_WALL_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   65.50 0.00 0.00 65.50 65.50 1.683 0.451 0.452             No CAFE_FLR_1_WALL_SOUTH 180.00 90.00 S
LOBBY_FLR_1_WALL_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   85.08 0.00 0.00 85.08 85.08 1.683 0.451 0.452             No LOBBY_FLR_1_WALL_1_SOUTH 180.00 90.00 S
ROOM_1_FLR_3_WALL_SOUTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 18.40 1.683 0.451 0.452             No ROOM_1_FLR_3_WALL_SOUTH 180.00 90.00 S
ROOM_1_FLR_3_WALL_WEST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 34.34 1.683 0.451 0.452             No ROOM_1_FLR_3_WALL_WEST 270.00 90.00 W
ROOM_2_FLR_3_WALL_NORTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 18.40 1.683 0.451 0.452             No ROOM_2_FLR_3_WALL_NORTH 0.00 90.00 N
ROOM_2_FLR_3_WALL_WEST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 34.34 1.683 0.451 0.452             No ROOM_2_FLR_3_WALL_WEST 270.00 90.00 W
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   3.68 0.00 0.00 3.68 279.56 1.683 0.451 0.452             No ROOM_3_MULT19_FLR_3_WALL_SOUTH 180.00 90.00 S
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   3.68 0.00 0.00 3.68 279.65 1.683 0.451 0.452             No ROOM_4_MULT19_FLR_3_WALL_NORTH 0.00 90.00 N
ROOM_5_FLR_3_WALL_EAST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 34.34 1.683 0.451 0.452             No ROOM_5_FLR_3_WALL_EAST 90.00 90.00 E
ROOM_5_FLR_3_WALL_SOUTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 18.40 1.683 0.451 0.452             No ROOM_5_FLR_3_WALL_SOUTH 180.00 90.00 S
ROOM_6_FLR_3_WALL_NORTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 18.40 1.683 0.451 0.452             No ROOM_6_FLR_3_WALL_NORTH 0.00 90.00 N
ROOM_6_FLR_3_WALL_EAST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 34.34 1.683 0.451 0.452             No ROOM_6_FLR_3_WALL_EAST 90.00 90.00 E
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   5.82 0.00 0.00 5.82 23.30 1.683 0.451 0.452             No CORRIDOR_FLR_3_WALL_1_NORTH 0.00 90.00 N
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   2.15 0.00 0.00 2.15 8.59 1.683 0.451 0.452             No CORRIDOR_FLR_3_WALL_2_NORTH 0.00 90.00 N
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   2.15 0.00 0.00 2.15 8.58 1.683 0.451 0.452             No CORRIDOR_FLR_3_WALL_1_SOUTH 180.00 90.00 S
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   5.82 0.00 0.00 5.82 23.30 1.683 0.451 0.452             No CORRIDOR_FLR_3_WALL_2_SOUTH 180.00 90.00 S
ROOM_1_FLR_6_WALL_SOUTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 4.60 1.683 0.451 0.452             No ROOM_1_FLR_6_WALL_SOUTH 180.00 90.00 S
ROOM_1_FLR_6_WALL_WEST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 8.58 1.683 0.451 0.452             No ROOM_1_FLR_6_WALL_WEST 270.00 90.00 W
ROOM_2_FLR_6_WALL_NORTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 4.60 1.683 0.451 0.452             No ROOM_2_FLR_6_WALL_NORTH 0.00 90.00 N
ROOM_2_FLR_6_WALL_WEST_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   8.58 0.00 0.00 8.58 8.58 1.683 0.451 0.452             No ROOM_2_FLR_6_WALL_WEST 270.00 90.00 W
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW RESWINDOW_U_0.2964_SHGC_0.45   6.74 0.00 0.00 6.74 60.70 1.683 0.451 0.452             No ROOM_3_MULT9_FLR_6_WALL_SOUTH 180.00 90.00 S
BANQUET_FLR_6_WALL_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   32.19 0.00 0.00 32.19 32.19 1.683 0.451 0.452             No BANQUET_FLR_6_WALL_NORTH 0.00 90.00 N
DINING_FLR_6_WALL_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   32.19 0.00 0.00 32.19 32.19 1.683 0.451 0.452             No DINING_FLR_6_WALL_NORTH 0.00 90.00 N
KITCHEN_FLR_6_WALL_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 4.60 1.683 0.451 0.452             No KITCHEN_FLR_6_WALL_NORTH 0.00 90.00 N
KITCHEN_FLR_6_WALL_EAST_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   17.17 0.00 0.00 17.17 17.17 1.683 0.451 0.452             No KITCHEN_FLR_6_WALL_EAST 90.00 90.00 E
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   4.60 0.00 0.00 4.60 4.60 1.683 0.451 0.452             No KITCHEN_FLR_6_WALL_1_SOUTH 180.00 90.00 S
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   5.82 0.00 0.00 5.82 5.82 1.683 0.451 0.452             No CORRIDOR_FLR_6_WALL_1_NORTH 0.00 90.00 N
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   5.21 0.00 0.00 5.21 5.21 1.683 0.451 0.452             No CORRIDOR_FLR_6_WALL_2_NORTH 0.00 90.00 N
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW NONRESWINDOW_U_0.2964_SHGC_0.45   17.17 0.00 0.00 17.17 17.17 1.683 0.451 0.452             No CORRIDOR_FLR_6_WALL_2_SOUTH 180.00 90.00 S
Total or Average             1213.79 1.683 0.451 0.452                      
North Total or Average             432.95 1.683 0.451 0.452                      
Non-North Total or Average             780.84 1.683 0.451 0.452                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
RETAIL_2_FLR_1_WALL_WEST_DOOR SWINGING DOOR_CON 1.598 2.101 1.95 RETAIL_2_FLR_1_WALL_WEST
STORAGE_FLR_1_WALL_NORTH_ROLLDOOR OVERHEAD DOOR_CON 1.016 1.198 7.43 STORAGE_FLR_1_WALL_NORTH
LAUNDRY_FLR_1_WALL_EAST_DOOR SWINGING DOOR_CON 1.598 2.101 1.95 LAUNDRY_FLR_1_WALL_EAST
CAFE_FLR_1_WALL_EAST_DOOR SWINGING DOOR_CON 1.598 2.101 1.95 CAFE_FLR_1_WALL_EAST
LOBBY_FLR_1_WALL_1_NORTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 LOBBY_FLR_1_WALL_1_NORTH
LOBBY_FLR_1_WALL_1_NORTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 LOBBY_FLR_1_WALL_1_NORTH


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
CAFE_FLR_1_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
LOBBY_FLR_1_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_1_FLR_3_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_1_FLR_3_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
ROOM_2_FLR_3_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_3_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ROOM_5_FLR_3_WALL_EAST_WINDOW 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
ROOM_5_FLR_3_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_6_FLR_3_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ROOM_6_FLR_3_WALL_EAST_WINDOW 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_1_FLR_6_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
ROOM_1_FLR_6_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
ROOM_2_FLR_6_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_6_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
BANQUET_FLR_6_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
DINING_FLR_6_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
KITCHEN_FLR_6_WALL_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
KITCHEN_FLR_6_WALL_EAST_WINDOW 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
BASEMENT_LIGHTS BASEMENT BASEMENT GENERAL 9.1389 1978.83 18084.33 LightsWired LTG_SCH_BASEMENT 51.16 168.00 51.10 0.0000 Y 173.46
RETAIL_1_FLR_1_LIGHTS RETAIL_1_FLR_1 RETAIL_1_FLR_1 GENERAL 13.3365 67.07 894.50 LightsWired LTG_SCH_RETAIL 51.36 168.00 51.30 0.0000 Y 8.61
RETAIL_2_FLR_1_LIGHTS RETAIL_2_FLR_1 RETAIL_2_FLR_1 GENERAL 13.3365 77.67 1035.83 LightsWired LTG_SCH_RETAIL 51.36 168.00 51.30 0.0000 Y 9.97
MECH_FLR_1_LIGHTS MECH_FLR_1 MECH_FLR_1 GENERAL 9.2031 164.24 1511.55 LightsWired LTG_SCH_MECHANIC 58.69 168.00 58.63 0.0000 Y 16.63
STORAGE_FLR_1_LIGHTS STORAGE_FLR_1 STORAGE_FLR_1 GENERAL 6.1031 94.76 578.33 LightsWired LTG_SCH_STORAGE 25.68 168.00 25.65 0.0000 Y 2.78
LAUNDRY_FLR_1_LIGHTS LAUNDRY_FLR_1 LAUNDRY_FLR_1 GENERAL 5.8125 78.04 453.60 LightsWired LTG_SCH_LAUNDRY 51.36 168.00 51.30 0.0000 Y 4.37
CAFE_FLR_1_LIGHTS CAFE_FLR_1 CAFE_FLR_1 GENERAL 10.3656 188.86 1957.67 LightsWired LTG_SCH_DINING 58.69 168.00 48.75 0.0000 Y 17.92
LOBBY_FLR_1_LIGHTS LOBBY_FLR_1 LOBBY_FLR_1 GENERAL 8.7188 1308.19 11405.76 LightsWired LTG_SCH_LOBBY 58.69 168.00 56.93 0.0000 Y 121.89
ROOM_1_FLR_3_LIGHTS ROOM_1_FLR_3 ROOM_1_FLR_3 GENERAL 4.5531 156.09 710.69 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 6.37
ROOM_2_FLR_3_LIGHTS ROOM_2_FLR_3 ROOM_2_FLR_3 GENERAL 4.5531 156.07 710.61 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 6.37
ROOM_3_MULT19_FLR_3_LIGHTS ROOM_3_MULT19_FLR_3 ROOM_3_MULT19_FLR_3 GENERAL 4.5531 1863.81 8486.17 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 76.02
ROOM_4_MULT19_FLR_3_LIGHTS ROOM_4_MULT19_FLR_3 ROOM_4_MULT19_FLR_3 GENERAL 4.5531 1864.32 8488.49 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 76.04
ROOM_5_FLR_3_LIGHTS ROOM_5_FLR_3 ROOM_5_FLR_3 GENERAL 4.5531 156.09 710.69 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 6.37
ROOM_6_FLR_3_LIGHTS ROOM_6_FLR_3 ROOM_6_FLR_3 GENERAL 4.5531 156.07 710.61 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 6.37
CORRIDOR_FLR_3_LIGHTS CORRIDOR_FLR_3 CORRIDOR_FLR_3 GENERAL 6.3938 1557.62 9959.03 LightsWired LTG_SCH_CORRIDOR 58.69 168.00 58.63 0.0000 Y 109.60
ROOM_1_FLR_6_LIGHTS ROOM_1_FLR_6 ROOM_1_FLR_6 GENERAL 4.5531 39.02 177.67 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 1.59
ROOM_2_FLR_6_LIGHTS ROOM_2_FLR_6 ROOM_2_FLR_6 GENERAL 4.5531 39.02 177.65 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 1.59
ROOM_3_MULT9_FLR_6_LIGHTS ROOM_3_MULT9_FLR_6 ROOM_3_MULT9_FLR_6 GENERAL 4.5531 220.77 1005.22 LightsWired LTG_SCH_GUESTROOM 47.59 168.00 47.72 0.0000 Y 9.00
BANQUET_FLR_6_LIGHTS BANQUET_FLR_6 BANQUET_FLR_6 GENERAL 10.3656 331.66 3437.84 LightsWired LTG_SCH_DINING 58.69 168.00 53.67 0.0000 Y 34.64
DINING_FLR_6_LIGHTS DINING_FLR_6 DINING_FLR_6 GENERAL 10.3656 331.66 3437.84 LightsWired LTG_SCH_DINING 58.69 168.00 53.67 0.0000 Y 34.64
KITCHEN_FLR_6_LIGHTS KITCHEN_FLR_6 KITCHEN_FLR_6 GENERAL 11.7219 103.30 1210.92 LightsWired LTG_SCH_KITCHEN 58.69 168.00 58.63 0.0000 Y 13.33
CORRIDOR_FLR_6_LIGHTS CORRIDOR_FLR_6 CORRIDOR_FLR_6 GENERAL 6.3938 412.12 2635.02 LightsWired LTG_SCH_CORRIDOR 58.69 168.00 58.63 0.0000 Y 29.00
Interior Lighting Total       6.8557 11345.29 77780.02               507.20


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
LOBBY_FLR_1_DAYLREFPT1 LOBBY_FLR_1 LOBBY_FLR_1_DAYLCTRL SplitFlux Stepped 0.07 11405.76 798.40
LOBBY_FLR_1_DAYLREFPT2 LOBBY_FLR_1 LOBBY_FLR_1_DAYLCTRL SplitFlux Stepped 0.00 11405.76 0.00
CAFE_FLR_1_DAYLREFPT1 CAFE_FLR_1 CAFE_FLR_1_DAYLCTRL SplitFlux Stepped 0.39 1957.67 763.49
CAFE_FLR_1_DAYLREFPT2 CAFE_FLR_1 CAFE_FLR_1_DAYLCTRL SplitFlux Stepped 0.00 1957.67 0.00
DINING_FLR_6_DAYLREFPT1 DINING_FLR_6 DINING_FLR_6_DAYLCTRL SplitFlux Stepped 0.20 3437.84 687.57
DINING_FLR_6_DAYLREFPT2 DINING_FLR_6 DINING_FLR_6_DAYLCTRL SplitFlux Stepped 0.00 3437.84 0.00
BANQUET_FLR_6_DAYLREFPT1 BANQUET_FLR_6 BANQUET_FLR_6_DAYLCTRL SplitFlux Stepped 0.20 3437.84 687.57
BANQUET_FLR_6_DAYLREFPT2 BANQUET_FLR_6 BANQUET_FLR_6_DAYLCTRL SplitFlux Stepped 0.00 3437.84 0.00


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
EXTERIOR FACADE LIGHTING 15448.40 AstronomicalClock -   83.06 83.06 240.86
Exterior Lighting Total 15448.40           240.86



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
HEATSYS1 BOILER Boiler:HotWater 902840.68 0.81        
COOLSYS1 CHILLER1 Chiller:Electric:EIR 711369.19 2.96 711494.23 2.96 3.93 13.40


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
ROOM_1_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 14182.97 21458.84 17343.32 4115.52 0.81 - 2468.26 25.03
ROOM_2_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 12667.09 19158.79 15480.38 3678.41 0.81 - 2203.46 22.35
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 103543.01 157385.90 127493.37 29892.53 0.81 - 18182.85 184.42
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 65859.95 97962.14 78189.04 19773.10 0.80 - 11211.87 113.72
ROOM_5_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 13334.51 20171.70 16300.93 3870.77 0.81 - 2320.08 23.53
ROOM_6_FLR_3 FAN COIL COOLING COIL Coil:Cooling:Water 11986.79 18126.87 14644.77 3482.10 0.81 - 2084.67 21.14
ROOM_1_FLR_6 FAN COIL COOLING COIL Coil:Cooling:Water 3693.94 5589.61 4518.01 1071.60 0.81 - 642.96 6.52
ROOM_2_FLR_6 FAN COIL COOLING COIL Coil:Cooling:Water 3261.88 4933.97 3986.93 947.04 0.81 - 567.47 5.76
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL Coil:Cooling:Water 22169.31 33439.67 26964.00 6475.67 0.81 - 3842.63 38.97
VAV WITH REHEAT COOLING COIL Coil:Cooling:Water 421695.42 552805.70 395252.20 157553.50 0.71 - 70587.17 715.93
FLR_3_DOAS COOLING COIL Coil:Cooling:Water 38332.30 52427.63 36468.44 15959.19 0.70 - 7931.52 80.45
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
None              


DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
None                  


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
BASEMENT VAV BOX REHEAT COIL Coil:Heating:Water 9737.54 9786.56 -
RETAIL_1_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 6225.25 6251.13 -
RETAIL_2_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 2210.42 2220.13 -
MECH_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 3679.96 3693.93 -
STORAGE_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 2326.56 2335.39 -
LAUNDRY_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 12407.85 12470.56 -
CAFE_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 17280.07 17358.26 -
LOBBY_FLR_1 VAV BOX REHEAT COIL Coil:Heating:Water 41972.45 42164.60 -
ROOM_1_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 10951.56 11795.54 -
ROOM_2_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 10941.36 11784.55 -
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 61702.12 66457.98 -
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 61554.79 66299.33 -
ROOM_5_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 10932.85 11775.38 -
ROOM_6_FLR_3 FAN COIL HEATING COIL Coil:Heating:Water 10922.65 11764.39 -
CORRIDOR_FLR_3 VAV BOX REHEAT COIL Coil:Heating:Water 20585.68 20668.28 -
ROOM_1_FLR_6 FAN COIL HEATING COIL Coil:Heating:Water 3345.28 3602.99 -
ROOM_2_FLR_6 FAN COIL HEATING COIL Coil:Heating:Water 3341.81 3599.25 -
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL Coil:Heating:Water 15986.68 17218.29 -
BANQUET_FLR_6 VAV BOX REHEAT COIL Coil:Heating:Water 16205.70 16280.17 -
DINING_FLR_6 VAV BOX REHEAT COIL Coil:Heating:Water 16655.75 16732.53 -
KITCHEN_FLR_6 VAV BOX REHEAT COIL Coil:Heating:Water 11196.51 11252.07 -
CORRIDOR_FLR_6 VAV BOX REHEAT COIL Coil:Heating:Water 13744.05 13796.20 -
VAV WITH REHEAT HEATING COIL Coil:Heating:Water 495976.60 263444.45 -
FLR_3_DOAS HEATING COIL Coil:Heating:Water 42957.20 22817.28 -
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
LAUNDRY_FLR_1 EXHAUST FAN Fan:ZoneExhaust 0.39 125.00 0.24 76.61 324.68 1.00 2.78 General    
LOBBY_FLR_1 EXHAUST FAN Fan:ZoneExhaust 1.00 0.00 0.00 0.00   1.00 0.00 General    
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 1.31 919.39 703.64 1.00 1.14 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 1.17 820.31 703.64 1.00 1.16 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 9.62 6771.73 703.64 1.00 0.93 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 5.78 4065.93 703.64 1.00 0.96 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:20:00
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 1.23 863.96 703.64 1.00 1.15 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:40:00
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 1.10 775.88 703.64 1.00 1.17 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 0.34 239.54 703.64 1.00 1.63 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 0.30 211.29 703.64 1.00 1.71 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:10:00
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.39 270.90 2.02 1424.36 703.64 1.00 1.06 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00
BANQUET_FLR_6 EXHAUST FAN Fan:ZoneExhaust 1.00 0.00 0.87 0.00 0.00 1.00 0.00 General    
DINING_FLR_6 EXHAUST FAN Fan:ZoneExhaust 1.00 0.00 0.87 0.00 0.00 1.00 0.00 General    
KITCHEN_FLR_6 EXHAUST FAN Fan:ZoneExhaust 0.39 125.00 1.89 612.92 324.68 1.00 1.48 General    
VAV WITH REHEAT FAN Fan:VariableVolume 0.62 1389.42 23.68 53067.65 2240.64 1.00 1.11 General FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00
FLR_3_DOAS FAN Fan:ConstantVolume 0.58 622.50 2.05 2194.93 1070.05 1.00 1.30 General FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
COOLSYS1 PUMP SECONDARY Pump:VariableSpeed Intermittent 133527.72 0.025385 5230.98 206062.94 0.90 General
HEATSYS1 PUMP Pump:VariableSpeed Intermittent 180705.70 0.007898 2378.66 301156.09 0.90 General
COOLSYS1 PUMP Pump:ConstantSpeed Intermittent 92445.74 0.025385 3621.59 142664.32 0.90 General
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.000375 47.91 127739.32 0.30 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWH BOOSTER E WATER HEATER WaterHeater:Mixed 0.02 8000.00 1.00 1.24 1.15
SWH LAUNDRY G WATER HEATER WaterHeater:Mixed 1.14 163316.00 0.80 0.58 0.51
SWHSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.60 0.80 0.26 0.03



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
BASEMENT 33393.80 33393.80 16.88 2.465 2.465 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00922 23.42 0.00700 0.854 0.00
RETAIL_1_FLR_1 7629.63 7629.63 113.75 0.563 0.563 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 24.00 24.00 0.00879 27.40 0.00701 0.079 0.00
RETAIL_2_FLR_1 3376.66 3376.66 43.48 0.249 0.249 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 24.00 24.00 0.00931 27.09 0.00701 0.092 0.00
MECH_FLR_1 3082.03 3082.03 18.77 0.227 0.227 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:20:00 24.00 24.00 0.00863 27.20 0.00701 0.000 0.00
STORAGE_FLR_1 1492.20 1492.20 15.75 0.110 0.110 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:10:00 24.00 24.00 0.00873 27.30 0.00701 0.058 0.00
LAUNDRY_FLR_1 44955.94 44955.94 576.07 3.318 3.318 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:50:00 24.00 24.00 0.00854 27.40 0.00701 0.000 0.00
CAFE_FLR_1 28308.99 28308.99 149.89 2.091 2.091 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 24.00 23.99 0.00961 27.40 0.00701 0.676 0.00
LOBBY_FLR_1 73625.40 73625.40 56.28 5.436 5.436 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 24.00 23.99 0.00977 27.40 0.00701 1.894 0.00
ROOM_1_FLR_3 13138.47 13138.47 336.69 1.307 1.307 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 21.11 21.11 0.00853 25.46 0.00700 0.062 0.00
ROOM_2_FLR_3 11722.58 11722.58 300.44 1.166 1.166 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 21.11 21.11 0.00854 24.95 0.00700 0.062 0.00
ROOM_3_MULT19_FLR_3 96774.43 96774.43 3946.14 9.624 9.624 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 21.11 21.11 0.00848 27.40 0.00701 0.837 0.00
ROOM_4_MULT19_FLR_3 58101.53 58101.53 2368.54 5.778 5.778 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:20:00 21.11 21.11 0.00871 21.08 0.00700 0.837 0.00
ROOM_5_FLR_3 12346.39 12346.39 316.40 1.228 1.228 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:40:00 21.11 21.11 0.00853 24.54 0.00700 0.062 0.00
ROOM_6_FLR_3 11087.73 11087.73 284.17 1.103 1.103 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 21.11 21.11 0.00854 22.66 0.00700 0.062 0.00
CORRIDOR_FLR_3 23589.30 23589.30 60.58 1.741 1.741 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 24.00 24.00 0.00928 27.40 0.00701 0.475 0.00
ROOM_1_FLR_6 3423.11 3423.11 87.72 0.340 0.340 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 21.11 21.11 0.00853 25.46 0.00700 0.015 0.00
ROOM_2_FLR_6 3019.41 3019.41 77.39 0.300 0.300 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:10:00 21.11 21.11 0.00853 24.70 0.00700 0.015 0.00
ROOM_3_MULT9_FLR_6 20354.29 20354.29 829.75 2.024 2.024 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 21.11 21.11 0.00856 27.40 0.00701 0.099 0.00
BANQUET_FLR_6 29057.01 29057.01 87.61 2.147 2.147 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 24.00 23.99 0.01042 27.40 0.00701 1.188 0.00
DINING_FLR_6 30427.69 30427.69 91.74 2.248 2.248 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 24.00 23.99 0.01034 27.40 0.00701 1.188 0.00
KITCHEN_FLR_6 32032.78 32032.78 310.08 2.370 2.370 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 12:30:00 24.00 23.97 0.01001 26.48 0.00701 0.367 0.00
CORRIDOR_FLR_6 11696.74 11696.74 28.38 0.863 0.863 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 24.00 24.00 0.00890 27.40 0.00701 0.126 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
BASEMENT 3473.03 3473.03 1.76 0.151 0.854 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00800 -41.90 0.00006 0.854 0.00
RETAIL_1_FLR_1 4795.77 4795.77 71.50 0.209 0.209 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00755 -41.90 0.00006 0.079 0.00
RETAIL_2_FLR_1 1577.63 1577.63 20.31 0.069 0.092 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00748 -41.90 0.00006 0.092 0.00
MECH_FLR_1 3001.62 3001.62 18.28 0.131 0.131 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00737 -41.90 0.00006 0.000 0.00
STORAGE_FLR_1 1897.66 1897.66 20.03 0.083 0.083 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00742 -41.90 0.00006 0.058 0.00
LAUNDRY_FLR_1 3989.19 3989.19 51.12 0.174 0.174 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00735 -41.90 0.00006 0.000 0.00
CAFE_FLR_1 11971.05 11971.05 63.39 0.521 0.676 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00760 -41.90 0.00006 0.676 0.00
LOBBY_FLR_1 28170.42 28170.42 21.53 1.226 1.894 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00752 -41.90 0.00006 1.894 0.00
ROOM_1_FLR_3 10951.56 10951.56 280.65 0.480 0.480 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00755 -41.90 0.00006 0.062 0.00
ROOM_2_FLR_3 10941.36 10941.36 280.42 0.479 0.479 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00755 -41.90 0.00006 0.062 0.00
ROOM_3_MULT19_FLR_3 61702.12 61702.12 2516.01 2.702 2.702 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00757 -41.90 0.00006 0.837 0.00
ROOM_4_MULT19_FLR_3 61554.79 61554.79 2509.31 2.696 2.696 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00757 -41.90 0.00006 0.837 0.00
ROOM_5_FLR_3 10932.85 10932.85 280.17 0.479 0.479 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00755 -41.90 0.00006 0.062 0.00
ROOM_6_FLR_3 10922.65 10922.65 279.94 0.478 0.478 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00755 -41.90 0.00006 0.062 0.00
CORRIDOR_FLR_3 16164.00 16164.00 41.51 0.704 0.704 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00763 -41.90 0.00006 0.475 0.00
ROOM_1_FLR_6 3345.28 3345.28 85.73 0.146 0.146 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00763 -41.90 0.00006 0.015 0.00
ROOM_2_FLR_6 3341.81 3341.81 85.65 0.146 0.146 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00763 -41.90 0.00006 0.015 0.00
ROOM_3_MULT9_FLR_6 15986.68 15986.68 651.70 0.700 0.700 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.11 21.11 0.00764 -41.90 0.00006 0.099 0.00
BANQUET_FLR_6 10752.15 10752.15 32.42 0.468 1.188 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00771 -41.90 0.00006 1.188 0.00
DINING_FLR_6 10944.98 10944.98 33.00 0.477 1.188 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00772 -41.90 0.00006 1.188 0.00
KITCHEN_FLR_6 5184.61 5184.61 50.19 0.226 0.367 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 21.00 21.00 0.00728 -41.90 0.00006 0.367 0.00
CORRIDOR_FLR_6 11208.86 11208.86 27.20 0.488 0.488 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 21.00 21.00 0.00776 -41.90 0.00006 0.126 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
VAV WITH REHEAT 23.68 23.68 8.05 8.05 23.6842 11.6526 23.6842 0.4920 0.3000
FLR_3_DOAS 20.77 2.05 8.31 2.05 2.0513 2.0513 2.0513 1.0000 0.3000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
BASEMENT VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT BASEMENT VAV BOX 9737.542 9737.542 1.205208 0.00008519 209.086 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 9737.54 9737.54 1.205208 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00799968 50.9110 3473.03 0.00 9791.73 9791.73
RETAIL_1_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT RETAIL_1_FLR_1 VAV BOX 6225.246 6225.246 0.275375 0.00005446 157.801 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 6225.25 6225.25 0.275375 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00755428 48.1169 4795.77 0.00 6257.21 6257.21
RETAIL_2_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT RETAIL_2_FLR_1 VAV BOX 2210.415 2210.415 0.121878 0.00001934 53.038 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 2210.42 2210.42 0.121878 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00748206 47.6585 1577.63 0.00 2221.97 2221.97
MECH_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT MECH_FLR_1 VAV BOX 3679.960 3679.960 0.130684 0.00003219 100.428 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 3679.96 3679.96 0.130684 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00736663 46.9322 3001.62 0.00 3698.21 3698.21
STORAGE_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT STORAGE_FLR_1 VAV BOX 2326.557 2326.557 0.082620 0.00002035 63.493 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 2326.56 2326.56 0.082620 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00741794 47.2551 1897.66 0.00 2338.09 2338.09
LAUNDRY_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown 12407.846 12407.846 1.622447 0.00010855 265.240 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 12407.85 12407.85 1.622447 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00735065 46.8356 3989.19 0.00 12476.99 12476.99
CAFE_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CAFE_FLR_1 VAV BOX 17280.073 17280.073 1.022552 0.00015117 408.682 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 17280.07 17280.07 1.022552 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00760273 48.4206 11971.05 0.00 17371.98 17371.98
LOBBY_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown 41972.453 41972.453 2.658173 0.00036719 980.016 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 41972.45 41972.45 2.658173 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00752278 47.9148 28170.42 0.00 42196.50 42196.50
ROOM_1_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_3 FAN COIL 14182.967 -999.000 1.306621 0.00050657 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 unknown 7/21 17:30:00 14182.97 14075.10 1.306621 21.69 15.43 0.00853180 12.80 11.96 0.00850000 25.46 0.00700420 15.45 0.0000 21.11 0.00853180 53.8836 13138.47 0.00 14398.48 14033.61
ROOM_1_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_3 FAN COIL 10951.564 10951.564 0.479571 0.00009581 312.949 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 10951.56 10951.56 0.479571 21.11 14.33 0.00754973 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00754973 47.7623 10951.56 0.00 11805.69 11805.69
ROOM_2_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_3 FAN COIL 12667.092 -999.000 1.165811 0.00045243 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 unknown 7/21 18:00:00 12667.09 12559.99 1.165811 21.69 15.43 0.00853538 12.80 11.96 0.00850000 24.95 0.00700344 15.26 0.0000 21.11 0.00853538 53.9059 11722.58 0.00 12859.47 12523.23
ROOM_2_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_3 FAN COIL 10941.362 10941.362 0.479125 0.00009572 312.658 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 10941.36 10941.36 0.479125 21.11 14.33 0.00754937 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00754937 47.7601 10941.36 0.00 11794.70 11794.70
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT19_FLR_3 FAN COIL 103543.009 -999.000 9.623903 0.00369825 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 unknown 7/21 14:10:00 103543.01 103543.01 9.623903 21.69 15.38 0.00848217 12.80 11.94 0.00848217 27.40 0.00700714 16.15 0.0000 21.11 0.00848217 53.5735 96774.43 0.00 105109.71 103490.21
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT19_FLR_3 FAN COIL 61702.120 61702.120 2.702135 0.00053980 1763.184 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 61702.12 61702.12 2.702135 21.11 14.35 0.00757494 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00757494 47.9160 61702.12 0.00 66515.80 66515.80
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_4_MULT19_FLR_3 FAN COIL 65859.948 -999.000 5.778455 0.00235232 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:20:00 unknown 7/21 21:20:00 65859.95 62655.25 5.778455 21.69 15.59 0.00871220 12.80 11.96 0.00850000 21.08 0.00699765 13.80 0.0000 21.11 0.00871220 55.0085 58101.53 0.00 66836.31 62534.99
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_4_MULT19_FLR_3 FAN COIL 61554.794 61554.794 2.695683 0.00053851 1758.975 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 61554.79 61554.79 2.695683 21.11 14.35 0.00757386 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00757386 47.9093 61554.79 0.00 66356.98 66356.98
ROOM_5_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_5_FLR_3 FAN COIL 13334.510 -999.000 1.227848 0.00047627 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:40:00 unknown 7/21 10:40:00 13334.51 13227.45 1.227848 21.69 15.43 0.00853358 12.80 11.96 0.00850000 24.54 0.00700282 15.11 0.0000 21.11 0.00853358 53.8947 12346.39 0.00 13537.08 13188.60
ROOM_5_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_5_FLR_3 FAN COIL 10932.849 10932.849 0.478752 0.00009565 312.415 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 10932.85 10932.85 0.478752 21.11 14.33 0.00754900 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00754900 47.7578 10932.85 0.00 11785.52 11785.52
ROOM_6_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_6_FLR_3 FAN COIL 11986.787 -999.000 1.102675 0.00042813 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 unknown 7/21 09:30:00 11986.79 11880.56 1.102675 21.69 15.43 0.00853710 12.80 11.96 0.00850000 22.66 0.00700000 14.41 0.0000 21.11 0.00853710 53.9166 11087.73 0.00 12168.79 11845.91
ROOM_6_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_6_FLR_3 FAN COIL 10922.648 10922.648 0.478305 0.00009556 312.123 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 10922.65 10922.65 0.478305 21.11 14.33 0.00754864 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00754864 47.7555 10922.65 0.00 11774.52 11774.52
CORRIDOR_FLR_3 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CORRIDOR_FLR_3 VAV BOX 20585.675 20585.675 0.851330 0.00018009 532.448 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 20585.68 20585.68 0.851330 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00762523 48.5580 16164.00 0.00 20689.46 20689.46
ROOM_1_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_6 FAN COIL 3693.939 -999.000 0.340428 0.00013194 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 unknown 7/21 17:30:00 3693.94 3666.96 0.340428 21.69 15.43 0.00853053 12.80 11.96 0.00850000 25.46 0.00700420 15.45 0.0000 21.11 0.00853053 53.8757 3423.11 0.00 3750.08 3656.12
ROOM_1_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_6 FAN COIL 3345.284 3345.284 0.146491 0.00002927 95.590 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 3345.28 3345.28 0.146491 21.11 14.40 0.00762756 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00762756 48.2485 3345.28 0.00 3606.19 3606.19
ROOM_2_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_6 FAN COIL 3261.882 -999.000 0.300281 0.00011650 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:10:00 unknown 7/21 18:10:00 3261.88 3235.00 0.300281 21.69 15.43 0.00853448 12.80 11.96 0.00850000 24.70 0.00700305 15.17 0.0000 21.11 0.00853448 53.9003 3019.41 0.00 3311.43 3225.51
ROOM_2_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_6 FAN COIL 3341.807 3341.807 0.146339 0.00002924 95.490 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 3341.81 3341.81 0.146339 21.11 14.40 0.00762722 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00762722 48.2464 3341.81 0.00 3602.44 3602.44
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT9_FLR_6 FAN COIL 22169.312 -999.000 2.024289 0.00079182 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 unknown 7/21 14:10:00 22169.31 21832.08 2.024289 21.69 15.46 0.00856409 12.80 11.96 0.00850000 27.40 0.00700714 16.15 0.0000 21.11 0.00856409 54.0855 20354.29 0.00 22504.67 21771.84
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT9_FLR_6 FAN COIL 15986.677 15986.677 0.700080 0.00013986 456.810 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 15986.68 15986.68 0.700080 21.11 14.41 0.00764052 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.11 0.00764052 48.3282 15986.68 0.00 17233.66 17233.66
BANQUET_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown 16205.700 16205.700 1.049953 0.00014177 376.852 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 16205.70 16205.70 1.049953 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00771223 49.1067 10752.15 0.00 16292.31 16292.31
DINING_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown 16655.754 16655.754 1.099465 0.00014571 386.059 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 16655.75 16655.75 1.099465 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00771712 49.1375 10944.98 0.00 16744.86 16744.86
KITCHEN_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown 11196.511 11196.511 1.159015 0.00009795 244.416 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 11196.51 11196.51 1.159015 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00727813 46.3815 5184.61 0.00 11258.53 11258.53
CORRIDOR_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CORRIDOR_FLR_6 VAV BOX 13744.045 13744.045 0.488020 0.00012024 375.100 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 13744.05 13744.05 0.488020 16.70 13.04 0.00800000 40.00 21.00 0.00800000 -41.90 0.00006450 -41.90 0.0000 21.00 0.00775673 49.3857 11208.86 0.00 13812.20 13812.20
VAV WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoopHVAC VAV WITH REHEAT 421695.418 -999.000 23.684164 0.01506198 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 421695.42 421695.42 23.684164 25.67 16.64 0.00829822 10.95 10.95 0.00829822 27.40 0.00700714 16.15 49.2374 23.99 0.00950124 50.2919 320704.72 0.00 427127.71 409323.58
VAV WITH REHEAT HEATING COIL Coil:Heating:Water AirLoopHVAC VAV WITH REHEAT 495976.603 495976.603 7.105249 0.00433902 6515.431 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 495976.60 495976.60 7.105249 -41.90 -41.90 0.00006450 16.70 13.04 0.00800000 -41.90 0.00006450 -41.90 164.1246 21.00 0.00760200 48.4131 112037.88 0.00 318058.48 318058.48
FLR_3_DOAS COOLING COIL Coil:Cooling:Water AirLoopHVAC FLR_3_DOAS 38332.296 -999.000 2.051317 0.00136914 -999.000 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 38332.30 38332.30 2.051317 27.40 16.15 0.00700714 11.91 10.04 0.00700714 27.40 0.00700714 16.15 99.9965 21.11 0.00857142 54.1303 208882.52 0.00 38851.60 38851.60
FLR_3_DOAS HEATING COIL Coil:Heating:Water AirLoopHVAC FLR_3_DOAS 42957.200 42957.200 0.615395 0.00037581 564.310 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 42957.20 42957.20 0.615395 -41.90 -41.90 0.00006450 16.70 13.04 0.00800000 -41.90 0.00006450 -41.90 333.3216 21.11 0.00757496 47.9163 189679.10 0.00 27547.47 27547.47



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
BASEMENT VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT BASEMENT VAV BOX BASEMENT N/A N/A N/A Yes Yes Yes No 9737.542 9737.542 1.205208 0.00008519 209.086 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.0573 1.078545 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 9737.54 9737.54 1.0000 1.42870134 1.205208 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.08517958 60.00 32.22 27.78 0.000 9737.54 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00799968 21.00 0.00799968 50.9110 3473.03 0.00 9791.73 9791.73 1.42870134 16.60 13.15 0.00800000 36934.7 23.32 15.71 0.00800000 43788.3
RETAIL_1_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT RETAIL_1_FLR_1 VAV BOX RETAIL_1_FLR_1 N/A N/A N/A Yes Yes Yes No 6225.246 6225.246 0.275375 0.00005446 157.801 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.6759 0.689518 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 6225.25 6225.25 1.0000 0.32644058 0.275375 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.05445561 60.00 32.22 27.78 0.000 6225.25 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00755428 21.00 0.00755428 48.1169 4795.77 0.00 6257.21 6257.21 0.32644058 16.60 13.15 0.00800000 36934.7 35.40 19.78 0.00800000 56102.7
RETAIL_2_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT RETAIL_2_FLR_1 VAV BOX RETAIL_2_FLR_1 N/A N/A N/A Yes Yes Yes No 2210.415 2210.415 0.121878 0.00001934 53.038 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.2400 0.244829 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 2210.42 2210.42 1.0000 0.14447939 0.121878 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.01933570 60.00 32.22 27.78 0.000 2210.42 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00748206 21.00 0.00748206 47.6585 1577.63 0.00 2221.97 2221.97 0.14447939 16.60 13.15 0.00800000 36934.7 31.68 18.59 0.00800000 52313.9
MECH_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT MECH_FLR_1 VAV BOX MECH_FLR_1 N/A N/A N/A Yes Yes Yes No 3679.960 3679.960 0.130684 0.00003219 100.428 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.3996 0.407598 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 3679.96 3679.96 1.0000 0.15491818 0.130684 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.03219061 60.00 32.22 27.78 0.000 3679.96 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00736663 21.00 0.00736663 46.9322 3001.62 0.00 3698.21 3698.21 0.15491818 16.60 13.15 0.00800000 36934.7 40.01 21.19 0.00800000 60806.8
STORAGE_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT STORAGE_FLR_1 VAV BOX STORAGE_FLR_1 N/A N/A N/A Yes Yes Yes No 2326.557 2326.557 0.082620 0.00002035 63.493 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.2526 0.257693 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 2326.56 2326.56 1.0000 0.09794121 0.082620 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.02035166 60.00 32.22 27.78 0.000 2326.56 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00741794 21.00 0.00741794 47.2551 1897.66 0.00 2338.09 2338.09 0.09794121 16.60 13.15 0.00800000 36934.7 40.01 21.19 0.00800000 60807.2
LAUNDRY_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown Unknown LAUNDRY_FLR_1 N/A N/A N/A Yes Yes Yes No 12407.846 12407.846 1.622447 0.00010855 265.240 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.3472 1.374312 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 12407.85 12407.85 1.0000 1.92331286 1.622447 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.10853818 60.00 32.22 27.78 0.000 12407.85 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00735065 21.00 0.00735065 46.8356 3989.19 0.00 12476.99 12476.99 1.92331286 16.60 13.15 0.00800000 36934.7 22.96 15.58 0.00800000 43422.0
CAFE_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CAFE_FLR_1 VAV BOX CAFE_FLR_1 N/A N/A N/A Yes Yes Yes No 17280.073 17280.073 1.022552 0.00015117 408.682 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.8762 1.913967 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 17280.07 17280.07 1.0000 1.21217320 1.022552 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.15115819 60.00 32.22 27.78 0.000 17280.07 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00760273 21.00 0.00760273 48.4206 11971.05 0.00 17371.98 17371.98 1.21217320 16.60 13.15 0.00800000 36934.7 30.65 18.26 0.00800000 51266.0
LOBBY_FLR_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown Unknown LOBBY_FLR_1 N/A N/A N/A Yes Yes Yes No 41972.453 41972.453 2.658173 0.00036719 980.016 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 4.5572 4.648932 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 41972.45 41972.45 1.0000 3.15110307 2.658173 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.36715587 60.00 32.22 27.78 0.000 41972.45 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00752278 21.00 0.00752278 47.9148 28170.42 0.00 42196.50 42196.50 3.15110307 16.60 13.15 0.00800000 36934.7 29.73 17.95 0.00800000 50325.8
ROOM_1_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_3 FAN COIL ROOM_1_FLR_3 N/A N/A N/A Yes Yes Yes No 14182.967 -999.000 1.306621 0.00050657 -999.000 -999.0000 1.00000 1.00000 1020.7002 1004.8586 1.1854 ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.306621 1.54892000   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 1.9956 1.995533 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 unknown unknown unknown 7/21 17:30:00 Sensible 14182.97 14075.10 1.0000 1.54892000 1.306621 21.69 15.43 0.00853180 43478.9 12.80 11.96 0.00850000 34322.2 0.50652158 6.70 13.37 6.67 0.000 14182.97 25.46 0.00700420 15.45 0.00000000 0.0000 21.11 0.00853180 21.11 0.00853180 53.8836 13138.47 0.00 14398.48 14033.61 1.54892000 21.69 15.59 0.00853180 43478.9 12.82 12.05 0.00843849 34183.1
ROOM_1_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_3 FAN COIL ROOM_1_FLR_3 N/A N/A N/A Yes Yes Yes No 10951.564 10951.564 0.479571 0.00009581 312.949 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.306621 1.54892000   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.1891 1.213012 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 10951.56 10951.56 1.0000 0.56850263 0.479571 21.11 14.33 0.00754973 40388.3 40.00 21.00 0.00800000 60796.0 0.09579929 60.00 32.22 27.78 0.000 10951.56 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00754973 21.11 0.00754973 47.7623 10951.56 0.00 11805.69 11805.69 0.56850263 16.60 12.71 0.00754973 35794.7 36.98 19.93 0.00754973 56561.0
ROOM_2_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_3 FAN COIL ROOM_2_FLR_3 N/A N/A N/A Yes Yes Yes No 12667.092 -999.000 1.165811 0.00045243 -999.000 -999.0000 1.00000 1.00000 1020.7068 1004.8586 1.1854 ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.165811 1.38199865   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 1.7823 1.782251 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 unknown unknown unknown 7/21 18:00:00 Sensible 12667.09 12559.99 1.0000 1.38199865 1.165811 21.69 15.43 0.00853538 43488.0 12.80 11.96 0.00850000 34322.2 0.45238457 6.70 13.37 6.67 0.000 12667.09 24.95 0.00700344 15.26 0.00000000 0.0000 21.11 0.00853538 21.11 0.00853538 53.9059 11722.58 0.00 12859.47 12523.23 1.38199865 21.69 15.59 0.00853538 43488.0 12.81 12.04 0.00843901 34183.0
ROOM_2_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_3 FAN COIL ROOM_2_FLR_3 N/A N/A N/A Yes Yes Yes No 10941.362 10941.362 0.479125 0.00009572 312.658 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.165811 1.38199865   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.1880 1.211882 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 10941.36 10941.36 1.0000 0.56797301 0.479125 21.11 14.33 0.00754937 40387.4 40.00 21.00 0.00800000 60796.0 0.09571004 60.00 32.22 27.78 0.000 10941.36 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00754937 21.11 0.00754937 47.7601 10941.36 0.00 11794.70 11794.70 0.56797301 16.60 12.71 0.00754937 35793.8 36.98 19.93 0.00754937 56560.1
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT19_FLR_3 FAN COIL ROOM_3_MULT19_FLR_3 N/A N/A N/A Yes Yes Yes No 103543.009 -999.000 9.623903 0.00369825 -999.000 -999.0000 1.00000 1.00000 1020.6079 1004.8586 1.1854 ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 9.623903 11.40855231   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 14.5687 14.568426 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 unknown unknown unknown 7/21 14:10:00 Sensible 103543.01 103543.01 1.0000 11.40855231 9.623903 21.69 15.38 0.00848217 43353.1 12.80 11.94 0.00848217 34277.2 3.69787005 6.70 13.37 6.67 0.000 103543.01 27.40 0.00700714 16.15 0.00000000 0.0000 21.11 0.00848217 21.11 0.00848217 53.5735 96774.43 0.00 105109.71 103490.21 11.40855231 21.69 15.54 0.00848217 43353.1 12.80 12.03 0.00842595 34139.9
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT19_FLR_3 FAN COIL ROOM_3_MULT19_FLR_3 N/A N/A N/A Yes Yes Yes No 61702.120 61702.120 2.702135 0.00053980 1763.184 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 9.623903 11.40855231   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 6.6994 6.834220 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 61702.12 61702.12 1.0000 3.20321735 2.702135 21.11 14.35 0.00757494 40453.7 40.00 21.00 0.00800000 60796.0 0.53974200 60.00 32.22 27.78 0.000 61702.12 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00757494 21.11 0.00757494 47.9160 61702.12 0.00 66515.80 66515.80 3.20321735 16.60 12.74 0.00757494 35858.6 36.98 19.95 0.00757494 56623.9
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_4_MULT19_FLR_3 FAN COIL ROOM_4_MULT19_FLR_3 N/A N/A N/A Yes Yes Yes No 65859.948 -999.000 5.778455 0.00235232 -999.000 -999.0000 1.00000 1.00000 1021.0356 1004.8586 1.1854 ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 5.778455 6.85000800   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 9.2666 9.266446 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:20:00 unknown unknown unknown 7/21 21:20:00 Sensible 65859.95 62655.25 1.0000 6.85000800 5.778455 21.69 15.59 0.00871220 43936.8 12.80 11.96 0.00850000 34322.2 2.35208085 6.70 13.37 6.67 0.000 65859.95 21.08 0.00699765 13.80 0.00000000 0.0000 21.11 0.00871220 21.11 0.00871220 55.0085 58101.53 0.00 66836.31 62534.99 6.85000800 21.69 15.74 0.00871220 43936.8 12.75 12.04 0.00846348 34179.7
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_4_MULT19_FLR_3 FAN COIL ROOM_4_MULT19_FLR_3 N/A N/A N/A Yes Yes Yes No 61554.794 61554.794 2.695683 0.00053851 1758.975 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 5.778455 6.85000800   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 6.6834 6.817902 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 61554.79 61554.79 1.0000 3.19556899 2.695683 21.11 14.35 0.00757386 40451.0 40.00 21.00 0.00800000 60796.0 0.53845326 60.00 32.22 27.78 0.000 61554.79 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00757386 21.11 0.00757386 47.9093 61554.79 0.00 66356.98 66356.98 3.19556899 16.60 12.73 0.00757386 35855.8 36.98 19.95 0.00757386 56621.1
ROOM_5_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_5_FLR_3 FAN COIL ROOM_5_FLR_3 N/A N/A N/A Yes Yes Yes No 13334.510 -999.000 1.227848 0.00047627 -999.000 -999.0000 1.00000 1.00000 1020.7035 1004.8586 1.1854 ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.227848 1.45553973   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 1.8762 1.876156 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:40:00 unknown unknown unknown 7/21 10:40:00 Sensible 13334.51 13227.45 1.0000 1.45553973 1.227848 21.69 15.43 0.00853358 43483.4 12.80 11.96 0.00850000 34322.2 0.47622034 6.70 13.37 6.67 0.000 13334.51 24.54 0.00700282 15.11 0.00000000 0.0000 21.11 0.00853358 21.11 0.00853358 53.8947 12346.39 0.00 13537.08 13188.60 1.45553973 21.69 15.59 0.00853358 43483.4 12.82 12.05 0.00843875 34183.0
ROOM_5_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_5_FLR_3 FAN COIL ROOM_5_FLR_3 N/A N/A N/A Yes Yes Yes No 10932.849 10932.849 0.478752 0.00009565 312.415 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.227848 1.45553973   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.1870 1.210939 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 10932.85 10932.85 1.0000 0.56753108 0.478752 21.11 14.33 0.00754900 40386.5 40.00 21.00 0.00800000 60796.0 0.09563557 60.00 32.22 27.78 0.000 10932.85 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00754900 21.11 0.00754900 47.7578 10932.85 0.00 11785.52 11785.52 0.56753108 16.60 12.71 0.00754900 35792.9 36.98 19.93 0.00754900 56559.2
ROOM_6_FLR_3 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_6_FLR_3 FAN COIL ROOM_6_FLR_3 N/A N/A N/A Yes Yes Yes No 11986.787 -999.000 1.102675 0.00042813 -999.000 -999.0000 1.00000 1.00000 1020.7100 1004.8586 1.1854 ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.102675 1.30715381   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 1.6866 1.686532 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 unknown unknown unknown 7/21 09:30:00 Sensible 11986.79 11880.56 1.0000 1.30715381 1.102675 21.69 15.43 0.00853710 43492.3 12.80 11.96 0.00850000 34322.2 0.42808859 6.70 13.37 6.67 0.000 11986.79 22.66 0.00700000 14.41 0.00000000 0.0000 21.11 0.00853710 21.11 0.00853710 53.9166 11087.73 0.00 12168.79 11845.91 1.30715381 21.69 15.59 0.00853710 43492.3 12.81 12.04 0.00843926 34183.0
ROOM_6_FLR_3 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_6_FLR_3 FAN COIL ROOM_6_FLR_3 N/A N/A N/A Yes Yes Yes No 10922.648 10922.648 0.478305 0.00009556 312.123 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN Fan:OnOff 1.102675 1.30715381   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.1859 1.209809 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 10922.65 10922.65 1.0000 0.56700154 0.478305 21.11 14.33 0.00754864 40385.6 40.00 21.00 0.00800000 60796.0 0.09554634 60.00 32.22 27.78 0.000 10922.65 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00754864 21.11 0.00754864 47.7555 10922.65 0.00 11774.52 11774.52 0.56700154 16.60 12.71 0.00754864 35792.0 36.98 19.93 0.00754864 56558.3
CORRIDOR_FLR_3 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CORRIDOR_FLR_3 VAV BOX CORRIDOR_FLR_3 N/A N/A N/A Yes Yes Yes No 20585.675 20585.675 0.851330 0.00018009 532.448 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 2.2351 2.280101 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 20585.68 20585.68 1.0000 1.00919963 0.851330 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.18007410 60.00 32.22 27.78 0.000 20585.68 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00762523 21.00 0.00762523 48.5580 16164.00 0.00 20689.46 20689.46 1.00919963 16.60 13.15 0.00800000 36934.7 36.70 20.19 0.00800000 57435.6
ROOM_1_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_6 FAN COIL ROOM_1_FLR_6 N/A N/A N/A Yes Yes Yes No 3693.939 -999.000 0.340428 0.00013194 -999.000 -999.0000 1.00000 1.00000 1020.6978 1004.8586 1.1854 ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.340428 0.40355683   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 0.5197 0.519735 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 unknown unknown unknown 7/21 17:30:00 Sensible 3693.94 3666.96 1.0000 0.40355683 0.340428 21.69 15.43 0.00853053 43475.7 12.80 11.96 0.00850000 34322.2 0.13192303 6.70 13.37 6.67 0.000 3693.94 25.46 0.00700420 15.45 0.00000000 0.0000 21.11 0.00853053 21.11 0.00853053 53.8757 3423.11 0.00 3750.08 3656.12 0.40355683 21.69 15.58 0.00853053 43475.7 12.82 12.05 0.00843831 34183.1
ROOM_1_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_1_FLR_6 FAN COIL ROOM_1_FLR_6 N/A N/A N/A Yes Yes Yes No 3345.284 3345.284 0.146491 0.00002927 95.590 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.340428 0.40355683   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.3632 0.370529 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 3345.28 3345.28 1.0000 0.17365651 0.146491 21.11 14.40 0.00762756 40586.1 40.00 21.00 0.00800000 60796.0 0.02926302 60.00 32.22 27.78 0.000 3345.28 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00762756 21.11 0.00762756 48.2485 3345.28 0.00 3606.19 3606.19 0.17365651 16.60 12.79 0.00762756 35991.8 36.98 19.99 0.00762756 56758.0
ROOM_2_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_6 FAN COIL ROOM_2_FLR_6 N/A N/A N/A Yes Yes Yes No 3261.882 -999.000 0.300281 0.00011650 -999.000 -999.0000 1.00000 1.00000 1020.7052 1004.8586 1.1854 ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.300281 0.35596463   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 0.4590 0.458944 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:10:00 unknown unknown unknown 7/21 18:10:00 Sensible 3261.88 3235.00 1.0000 0.35596463 0.300281 21.69 15.43 0.00853448 43485.7 12.80 11.96 0.00850000 34322.2 0.11649281 6.70 13.37 6.67 0.000 3261.88 24.70 0.00700305 15.17 0.00000000 0.0000 21.11 0.00853448 21.11 0.00853448 53.9003 3019.41 0.00 3311.43 3225.51 0.35596463 21.69 15.59 0.00853448 43485.7 12.81 12.04 0.00843888 34183.0
ROOM_2_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_2_FLR_6 FAN COIL ROOM_2_FLR_6 N/A N/A N/A Yes Yes Yes No 3341.807 3341.807 0.146339 0.00002924 95.490 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 0.300281 0.35596463   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 0.3628 0.370144 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 3341.81 3341.81 1.0000 0.17347600 0.146339 21.11 14.40 0.00762722 40585.2 40.00 21.00 0.00800000 60796.0 0.02923260 60.00 32.22 27.78 0.000 3341.81 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00762722 21.11 0.00762722 48.2464 3341.81 0.00 3602.44 3602.44 0.17347600 16.60 12.79 0.00762722 35990.9 36.98 19.99 0.00762722 56757.2
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL COIL:COOLING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT9_FLR_6 FAN COIL ROOM_3_MULT9_FLR_6 N/A N/A N/A Yes Yes Yes No 22169.312 -999.000 2.024289 0.00079182 -999.000 -999.0000 1.00000 1.00000 1020.7602 1004.8586 1.1854 ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 2.024289 2.39967166   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 3.1193 3.119206 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:10:00 unknown unknown unknown 7/21 14:10:00 Sensible 22169.31 21832.08 1.0000 2.39967166 2.024289 21.69 15.46 0.00856409 43560.7 12.80 11.96 0.00850000 34322.2 0.79174090 6.70 13.37 6.67 0.000 22169.31 27.40 0.00700714 16.15 0.00000000 0.0000 21.11 0.00856409 21.11 0.00856409 54.0855 20354.29 0.00 22504.67 21771.84 2.39967166 21.69 15.61 0.00856409 43560.7 12.80 12.04 0.00844313 34182.4
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:FOURPIPEFANCOIL ROOM_3_MULT9_FLR_6 FAN COIL ROOM_3_MULT9_FLR_6 N/A N/A N/A Yes Yes Yes No 15986.677 15986.677 0.700080 0.00013986 456.810 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN Fan:OnOff 2.024289 2.39967166   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.7358 1.770709 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 15986.68 15986.68 1.0000 0.82990242 0.700080 21.11 14.41 0.00764052 40619.5 40.00 21.00 0.00800000 60796.0 0.13984416 60.00 32.22 27.78 0.000 15986.68 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.11 0.00764052 21.11 0.00764052 48.3282 15986.68 0.00 17233.66 17233.66 0.82990242 16.60 12.80 0.00764052 36024.6 36.98 20.00 0.00764052 56790.5
BANQUET_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown Unknown BANQUET_FLR_6 N/A N/A N/A Yes Yes Yes No 16205.700 16205.700 1.049953 0.00014177 376.852 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.7596 1.794968 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 16205.70 16205.70 1.0000 1.24465512 1.049953 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.14176007 60.00 32.22 27.78 0.000 16205.70 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00771223 21.00 0.00771223 49.1067 10752.15 0.00 16292.31 16292.31 1.24465512 16.60 13.15 0.00800000 36934.7 29.44 17.85 0.00800000 50024.6
DINING_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown Unknown DINING_FLR_6 N/A N/A N/A Yes Yes Yes No 16655.754 16655.754 1.099465 0.00014571 386.059 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.8084 1.844817 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 16655.75 16655.75 1.0000 1.30334899 1.099465 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.14569694 60.00 32.22 27.78 0.000 16655.75 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00771712 21.00 0.00771712 49.1375 10944.98 0.00 16744.86 16744.86 1.30334899 16.60 13.15 0.00800000 36934.7 29.20 17.77 0.00800000 49782.3
KITCHEN_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Unknown Unknown Unknown KITCHEN_FLR_6 N/A N/A N/A Yes Yes Yes No 11196.511 11196.511 1.159015 0.00009795 244.416 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.2157 1.240142 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 23:30:00 Sensible 11196.51 11196.51 1.0000 1.37394206 1.159015 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.09794197 60.00 32.22 27.78 0.000 11196.51 -41.90 0.00006450 -41.90 0.00000000 0.0000 20.80 0.00727813 21.00 0.00727813 46.3815 5184.61 0.00 11258.53 11258.53 1.37394206 16.60 13.15 0.00800000 36934.7 24.64 16.18 0.00800000 45129.1
CORRIDOR_FLR_6 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CORRIDOR_FLR_6 VAV BOX CORRIDOR_FLR_6 N/A N/A N/A Yes Yes Yes No 13744.045 13744.045 0.488020 0.00012024 375.100 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 unknown unknown -999.0 -999.0   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 1.4923 1.522311 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 13744.05 13744.05 1.0000 0.57851796 0.488020 16.70 13.04 0.00800000 37036.7 40.00 21.00 0.00800000 60796.0 0.12022664 60.00 32.22 27.78 0.000 13744.05 -41.90 0.00006450 -41.90 0.00000000 0.0000 21.00 0.00775673 21.00 0.00775673 49.3857 11208.86 0.00 13812.20 13812.20 0.57851796 16.60 13.15 0.00800000 36934.7 40.01 21.19 0.00800000 60809.9
VAV WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC VAV WITH REHEAT BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; Coincident CoolingDesignCapacity N/A Yes Yes Yes No 421695.418 -999.000 23.684164 0.01506198 -999.000 -999.0000 1.00000 1.00000 1020.2660 1004.8586 1.1854 VAV WITH REHEAT FAN Fan:VariableVolume 23.684164 28.07613810   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 59.3333 59.333345 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 Sensible 421695.42 421695.42 1.0000 28.07613810 23.684164 25.67 16.64 0.00829822 46942.3 10.95 10.95 0.00829822 31922.6 15.06044678 6.70 13.37 6.67 53067.651 368627.77 27.40 0.00700714 16.15 11.66146000 49.2374 23.99 0.00955050 23.99 0.00950124 50.2919 320704.72 0.00 427127.71 409323.58 28.07613810 25.67 16.80 0.00829822 46942.3 11.38 11.04 0.00804678 31729.1
VAV WITH REHEAT HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC VAV WITH REHEAT BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; Coincident HeatingDesignCapacity N/A Yes Yes Yes No 495976.603 495976.603 7.105249 0.00433902 6515.431 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 VAV WITH REHEAT FAN Fan:VariableVolume 23.684164 28.07613810   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 53.8513 54.935119 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 495976.60 495976.60 1.0000 8.42284143 7.105249 -41.90 -41.90 0.00006450 -41946.5 16.70 13.04 0.00800000 37036.7 4.33857706 60.00 32.22 27.78 0.000 495976.60 -41.90 0.00006450 -41.90 11.66146000 164.1246 20.98 0.00763022 21.00 0.00760200 48.4131 112037.88 0.00 318058.48 318058.48 8.42284143 2.80 -4.37 0.00006450 2975.2 40.38 14.79 0.00006450 40736.6
FLR_3_DOAS COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC FLR_3_DOAS ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; Coincident CoolingDesignCapacity N/A Yes Yes Yes No 38332.296 -999.000 2.051317 0.00136914 -999.000 -999.0000 1.00000 1.00000 1017.8659 1004.8586 1.1854 FLR_3_DOAS FAN Fan:ConstantVolume 2.051245 2.43162656   4197.9300 999.8980 25.38277065 13.37 6.70 6.67 710722.48 5.3934 5.393427 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 Sensible 38332.30 38332.30 1.0000 2.43171206 2.051317 27.40 16.15 0.00700714 45414.0 11.91 10.04 0.00700714 29650.5 1.36900115 6.70 13.37 6.67 2195.006 36137.29 27.40 0.00700714 16.15 2.05124512 99.9965 21.11 0.00856612 21.11 0.00857142 54.1303 208882.52 0.00 38851.60 38851.60 2.43171206 27.40 16.31 0.00700714 45414.0 11.70 10.08 0.00700714 29436.9
FLR_3_DOAS HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC FLR_3_DOAS ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; Coincident HeatingDesignCapacity N/A Yes Yes Yes No 42957.200 42957.200 0.615395 0.00037581 564.310 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1854 FLR_3_DOAS FAN Fan:ConstantVolume 2.051245 2.43162656   4197.9300 999.8980 7.89763844 54.44 82.22 27.78 921010.71 4.6641 4.758004 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 unknown unknown FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 24:00:00 Sensible 42957.20 42957.20 1.0000 0.72951362 0.615395 -41.90 -41.90 0.00006450 -41946.5 16.70 13.04 0.00800000 37036.7 0.37576999 60.00 32.22 27.78 0.000 42957.20 -41.90 0.00006450 -41.90 2.05124512 333.3216 21.11 0.00757603 21.11 0.00757496 47.9163 189679.10 0.00 27547.47 27547.47 0.72951362 2.80 -4.37 0.00006450 2975.2 40.38 14.79 0.00006450 40736.6



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
VAV WITH REHEAT_OA_CONTROLLER DifferentialDryBulb 11.66 23.68 -      
FLR_3_DOAS_OA_CONTROLLER DifferentialDryBulb 2.05 2.05 -      


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
BASEMENT VAV WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
RETAIL_1_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.001181 0.000000 0.000000 Flow/Area   1.00 1.00  
RETAIL_2_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.001181 0.000000 0.000000 Flow/Area   1.00 1.00  
MECH_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.000000 0.000000 0.000000 Flow/Area   1.00 1.00  
STORAGE_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.000610 0.000000 0.000000 Flow/Area   1.00 1.00  
LAUNDRY_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.000000 0.000000 0.000000 Flow/Area   1.00 1.00  
CAFE_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.003581 0.000000 0.000000 Flow/Area   1.00 1.00  
LOBBY_FLR_1 VAV WITH REHEAT_DCV 0.000000 0.001448 0.000000 0.000000 Flow/Area   1.00 1.00  
CORRIDOR_FLR_3 VAV WITH REHEAT_DCV 0.000000 0.000305 0.000000 0.000000 Flow/Area   1.00 1.00  
BANQUET_FLR_6 VAV WITH REHEAT_DCV 0.000000 0.003581 0.000000 0.000000 Flow/Area   1.00 1.00  
DINING_FLR_6 VAV WITH REHEAT_DCV 0.000000 0.003581 0.000000 0.000000 Flow/Area   1.00 1.00  
KITCHEN_FLR_6 VAV WITH REHEAT_DCV 0.000000 0.003556 0.000000 0.000000 Flow/Area   1.00 1.00  
CORRIDOR_FLR_6 VAV WITH REHEAT_DCV 0.000000 0.000305 0.000000 0.000000 Flow/Area   1.00 1.00  


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
BASEMENT 288.50 7792.50 252.33
RETAIL_1_FLR_1 4274.83 7973.50 3805.33
RETAIL_2_FLR_1 2416.00 7817.17 2192.50
MECH_FLR_1 3687.33 8522.67 3669.33
STORAGE_FLR_1 3987.00 8723.00 3987.00
LAUNDRY_FLR_1 5889.83 3743.67 2164.33
CAFE_FLR_1 4017.50 6933.17 2927.17
LOBBY_FLR_1 2398.67 6535.00 1496.67
ROOM_1_FLR_3 4652.83 8498.00 4624.33
ROOM_2_FLR_3 4956.17 8684.33 4950.17
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 4659.33 8760.00 4659.33
ROOM_5_FLR_3 4530.00 8296.33 4414.33
ROOM_6_FLR_3 4758.50 8508.17 4737.00
CORRIDOR_FLR_3 3607.50 8505.67 3599.50
ROOM_1_FLR_6 4957.67 8474.33 4909.17
ROOM_2_FLR_6 5228.17 8663.50 5220.33
ROOM_3_MULT9_FLR_6 4323.00 8248.67 4181.00
BANQUET_FLR_6 2849.83 4551.17 475.33
DINING_FLR_6 3115.00 3902.50 243.33
KITCHEN_FLR_6 7580.50 5980.17 5148.17
CORRIDOR_FLR_6 3891.50 8123.50 3777.33
Facility 8759.67 8760.00 7978.67
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
BASEMENT 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 37.50 0.00 37.50 0.00
RETAIL_2_FLR_1 1.83 0.00 1.83 0.00
MECH_FLR_1 0.00 0.00 0.00 0.00
STORAGE_FLR_1 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 0.50 125.50 0.50 125.50
CAFE_FLR_1 22.17 0.67 22.17 0.67
LOBBY_FLR_1 5.83 0.00 5.83 0.00
ROOM_1_FLR_3 0.00 1.83 0.00 1.83
ROOM_2_FLR_3 0.00 1.17 0.00 1.17
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 7.33 1.50 7.33 1.50
ROOM_5_FLR_3 0.00 15.33 0.00 15.33
ROOM_6_FLR_3 0.00 23.00 0.00 23.00
CORRIDOR_FLR_3 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 0.00 2.33 0.00 2.33
ROOM_2_FLR_6 0.00 1.17 0.00 1.17
ROOM_3_MULT9_FLR_6 0.00 3.33 0.00 3.33
BANQUET_FLR_6 0.00 26.50 0.00 26.50
DINING_FLR_6 0.00 32.00 0.00 32.00
KITCHEN_FLR_6 0.00 242.83 0.00 242.83
CORRIDOR_FLR_6 0.00 0.00 0.00 0.00
Facility 51.17 297.17 51.17 297.17
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
BASEMENT 61.80 106.50 4826.41 0.880 0.000 0.000 0.000
RETAIL_1_FLR_1 6.28 10.83 265.76 3.535 0.145 0.000 0.000
RETAIL_2_FLR_1 7.28 12.54 307.76 1.353 0.048 0.000 0.000
MECH_FLR_1 1.54 2.65 650.80 0.579 0.054 0.000 0.000
STORAGE_FLR_1 1.18 2.04 375.47 0.485 0.054 0.000 0.000
LAUNDRY_FLR_1 4.87 8.40 309.22 20.985 0.156 0.000 0.000
CAFE_FLR_1 82.58 142.30 748.35 4.684 0.114 0.000 0.000
LOBBY_FLR_1 245.14 422.44 5183.56 1.775 0.047 0.000 0.000
ROOM_1_FLR_3 0.95 1.50 118.94 0.474 0.187 0.000 0.031
ROOM_2_FLR_3 0.95 1.50 118.93 0.474 0.187 0.000 0.032
ROOM_3_MULT19_FLR_3   1.50 74.75        
ROOM_4_MULT19_FLR_3 0.95 1.50 74.77 0.538 0.083 0.000 0.050
ROOM_5_FLR_3 0.95 1.50 118.94 0.474 0.187 0.000 0.031
ROOM_6_FLR_3 0.95 1.50 118.93 0.474 0.187 0.000 0.032
CORRIDOR_FLR_3 12.16 20.96 1186.91 0.607 0.023 0.000 0.000
ROOM_1_FLR_6 0.95 1.50 118.94 0.474 0.187 0.000 0.036
ROOM_2_FLR_6 0.95 1.50 118.93 0.474 0.187 0.000 0.038
ROOM_3_MULT9_FLR_6 0.95 1.50 74.77 0.539 0.153 0.000 0.058
BANQUET_FLR_6 145.01 249.90 1010.89 4.176 0.054 0.000 0.000
DINING_FLR_6 145.01 249.90 1010.89 4.505 0.054 0.000 0.000
KITCHEN_FLR_6 12.90 22.24 314.87 19.656 0.156 0.000 0.000
CORRIDOR_FLR_6 12.87 22.18 1256.16 1.140 0.038 0.000 0.000
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
BASEMENT 61.80 106.50 4826.41 0.508 0.000 0.000 0.000
RETAIL_1_FLR_1 6.28 10.83 265.76 1.977 0.002 0.000 0.000
RETAIL_2_FLR_1 7.28 12.54 307.76 0.775 0.001 0.000 0.000
MECH_FLR_1 1.54 2.65 650.80 0.328 0.001 0.000 0.000
STORAGE_FLR_1 1.18 2.04 375.47 0.275 0.001 0.000 0.000
LAUNDRY_FLR_1 4.87 8.40 309.22 10.231 0.002 0.000 0.000
CAFE_FLR_1 82.58 142.30 748.35 2.673 0.002 0.000 0.000
LOBBY_FLR_1 245.14 422.44 5183.56 1.018 0.001 0.000 0.000
ROOM_1_FLR_3 0.95 1.50 118.94 0.457 0.003 0.000 0.000
ROOM_2_FLR_3 0.95 1.50 118.93 0.457 0.003 0.000 0.000
ROOM_3_MULT19_FLR_3   1.50 74.75        
ROOM_4_MULT19_FLR_3 0.95 1.50 74.77 0.519 0.001 0.000 0.000
ROOM_5_FLR_3 0.95 1.50 118.94 0.457 0.003 0.000 0.000
ROOM_6_FLR_3 0.95 1.50 118.93 0.457 0.003 0.000 0.000
CORRIDOR_FLR_3 12.16 20.96 1186.91 0.344 0.000 0.000 0.000
ROOM_1_FLR_6 0.95 1.50 118.94 0.457 0.003 0.000 0.000
ROOM_2_FLR_6 0.95 1.50 118.93 0.457 0.003 0.000 0.000
ROOM_3_MULT9_FLR_6 0.95 1.50 74.77 0.519 0.002 0.000 0.000
BANQUET_FLR_6 145.01 249.90 1010.89 2.570 0.001 0.000 0.000
DINING_FLR_6 145.01 249.90 1010.89 2.827 0.001 0.000 0.000
KITCHEN_FLR_6 12.90 22.24 314.87 7.602 0.002 0.000 0.000
CORRIDOR_FLR_6 12.87 22.18 1256.16 0.644 0.001 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
BASEMENT VAV WITH REHEAT 61.80 106.50 4826.41 1978.83 0.0000 0.854
RETAIL_1_FLR_1 VAV WITH REHEAT 6.28 10.83 265.76 67.07 0.0000 0.079
RETAIL_2_FLR_1 VAV WITH REHEAT 7.28 12.54 307.76 77.67 0.0000 0.092
MECH_FLR_1 VAV WITH REHEAT 1.54 2.65 650.80 164.24 0.0000 0.000
STORAGE_FLR_1 VAV WITH REHEAT 1.18 2.04 375.47 94.76 0.0000 0.058
LAUNDRY_FLR_1 VAV WITH REHEAT 4.87 8.40 309.22 78.04 0.0000 0.000
CAFE_FLR_1 VAV WITH REHEAT 82.58 142.30 748.35 188.86 0.0000 0.676
LOBBY_FLR_1 VAV WITH REHEAT 245.14 422.44 5183.56 1308.19 0.0000 1.894
ROOM_1_FLR_3 FLR_3_DOAS 0.95 1.50 118.94 39.02 0.0000 0.062
ROOM_2_FLR_3 FLR_3_DOAS 0.95 1.50 118.93 39.02 0.0000 0.062
ROOM_3_MULT19_FLR_3 FLR_3_DOAS   1.50 74.75 24.52 0.0000 0.837
ROOM_4_MULT19_FLR_3 FLR_3_DOAS 0.95 1.50 74.77 24.53 0.0000 0.837
ROOM_5_FLR_3 FLR_3_DOAS 0.95 1.50 118.94 39.02 0.0000 0.062
ROOM_6_FLR_3 FLR_3_DOAS 0.95 1.50 118.93 39.02 0.0000 0.062
CORRIDOR_FLR_3 VAV WITH REHEAT 12.16 20.96 1186.91 389.40 0.0000 0.475
ROOM_1_FLR_6 FLR_3_DOAS 0.95 1.50 118.94 39.02 0.0000 0.015
ROOM_2_FLR_6 FLR_3_DOAS 0.95 1.50 118.93 39.02 0.0000 0.015
ROOM_3_MULT9_FLR_6 FLR_3_DOAS 0.95 1.50 74.77 24.53 0.0000 0.099
BANQUET_FLR_6 VAV WITH REHEAT 145.01 249.90 1010.89 331.66 0.0000 1.188
DINING_FLR_6 VAV WITH REHEAT 145.01 249.90 1010.89 331.66 0.0000 1.188
KITCHEN_FLR_6 VAV WITH REHEAT 12.90 22.24 314.87 103.30 0.0000 0.367
CORRIDOR_FLR_6 VAV WITH REHEAT 12.87 22.18 1256.16 412.12 0.0000 0.126
Total Facility   873.39 1604.23 35184.81 11345.29 0.0000 137.584


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
BASEMENT 36398406.09 0.00 36398406.09 0.00 36398406.09 26946214.98 80.16 11.28 8668.56 0.00
RETAIL_1_FLR_1 8102502.49 0.00 8102502.49 331381.90 8433884.39 2498216.28 0.00 0.00 8760.00 0.00
RETAIL_2_FLR_1 3579799.00 0.00 3579799.00 127913.83 3707712.83 2892943.94 263.71 98.63 8397.66 0.00
MECH_FLR_1 3244883.23 0.00 3244883.23 302312.31 3547195.54 0.00 0.00 0.00 8760.00 0.00
STORAGE_FLR_1 1568902.97 0.00 1568902.97 174417.55 1743320.52 1821682.01 8760.00 0.00 0.00 0.00
LAUNDRY_FLR_1 55649589.41 0.00 55649589.41 412792.02 56062381.43 0.00 0.00 0.00 8760.00 0.00
CAFE_FLR_1 30144309.61 0.00 30144309.61 732538.45 30876848.06 21330615.53 67.45 4.67 8687.88 0.00
LOBBY_FLR_1 78950978.89 0.00 78950978.89 2093029.67 81044008.56 59728886.00 84.47 17.20 8658.33 0.00
ROOM_1_FLR_3 1946875.62 31886.35 1978761.97 192345.67 2171107.64 1946875.62 0.00 8259.17 500.83 0.00
ROOM_2_FLR_3 1946647.51 32698.72 1979346.24 192330.99 2171677.23 1946647.51 0.00 8259.17 500.83 0.00
ROOM_3_MULT19_FLR_3 26397887.27 35012.24 26432899.51 53666.60 26486566.11 26397887.27 0.00 8272.17 487.83 8760.00
ROOM_4_MULT19_FLR_3 26405105.73 32330.15 26437435.88 53681.27 26491117.15 26405105.73 0.00 8281.66 478.34 0.00
ROOM_5_FLR_3 1946875.62 31898.82 1978774.44 192345.67 2171120.10 1946875.62 0.00 8259.21 500.79 0.00
ROOM_6_FLR_3 1946647.51 32659.88 1979307.39 192330.99 2171638.38 1946647.51 0.00 8259.17 500.83 0.00
CORRIDOR_FLR_3 24813674.34 0.00 24813674.34 232584.61 25046258.95 14972100.18 0.47 5.54 8753.99 0.00
ROOM_1_FLR_6 486718.90 37394.45 524113.36 192388.03 716501.38 486718.90 0.00 8258.83 501.17 0.00
ROOM_2_FLR_6 486661.88 38481.07 525142.95 192373.35 717516.30 486661.88 0.00 8258.83 501.17 0.00
ROOM_3_MULT9_FLR_6 3126920.42 37358.59 3164279.00 98432.45 3262711.45 3126920.42 0.00 8258.85 501.15 0.00
BANQUET_FLR_6 36067008.13 0.00 36067008.13 469763.21 36536771.34 37458366.31 6013.43 202.43 2544.14 0.00
DINING_FLR_6 38898093.70 0.00 38898093.70 469763.21 39367856.91 37458366.31 4879.89 224.94 3655.17 0.00
KITCHEN_FLR_6 52844776.78 0.00 52844776.78 420546.99 53265323.77 11584760.86 0.00 0.00 8760.00 0.00
CORRIDOR_FLR_6 12335127.38 0.00 12335127.38 411607.93 12746735.30 3961413.96 0.00 0.00 8760.00 0.00
Total Facility 0.45E+10 6046699.66 0.45E+10 19382910.50 0.46E+10 0.43E+10 8760.00 8307.70 8760.00 8760.00


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
BASEMENT 1.1542 0.0000 1.1542 0.0000 1.1542 0.8545 80.16 11.28 8668.56
RETAIL_1_FLR_1 0.2569 0.0000 0.2569 0.0105 0.2674 0.0792 0.00 0.00 8760.00
RETAIL_2_FLR_1 0.1135 0.0000 0.1135 0.0041 0.1176 0.0917 263.71 98.63 8397.66
MECH_FLR_1 0.1029 0.0000 0.1029 0.0096 0.1125 0.0000 0.00 0.00 8760.00
STORAGE_FLR_1 0.0497 0.0000 0.0497 0.0055 0.0553 0.0578 8760.00 0.00 0.00
LAUNDRY_FLR_1 1.7646 0.0000 1.7646 0.0131 1.7777 0.0000 0.00 0.00 8760.00
CAFE_FLR_1 0.9559 0.0000 0.9559 0.0232 0.9791 0.6764 67.45 4.67 8687.88
LOBBY_FLR_1 2.5035 0.0000 2.5035 0.0664 2.5699 1.8940 84.47 17.20 8658.33
ROOM_1_FLR_3 0.0617 0.0010 0.0627 0.0061 0.0688 0.0617 0.00 8259.17 500.83
ROOM_2_FLR_3 0.0617 0.0010 0.0628 0.0061 0.0689 0.0617 0.00 8259.17 500.83
ROOM_4_MULT19_FLR_3 0.8373 0.0010 0.8383 0.0017 0.8400 0.8373 0.00 8281.66 478.34
ROOM_5_FLR_3 0.0617 0.0010 0.0627 0.0061 0.0688 0.0617 0.00 8259.21 500.79
ROOM_6_FLR_3 0.0617 0.0010 0.0628 0.0061 0.0689 0.0617 0.00 8259.17 500.83
CORRIDOR_FLR_3 0.7868 0.0000 0.7868 0.0074 0.7942 0.4748 0.47 5.54 8753.99
ROOM_1_FLR_6 0.0154 0.0012 0.0166 0.0061 0.0227 0.0154 0.00 8258.83 501.17
ROOM_2_FLR_6 0.0154 0.0012 0.0167 0.0061 0.0228 0.0154 0.00 8258.83 501.17
ROOM_3_MULT9_FLR_6 0.0992 0.0012 0.1003 0.0031 0.1035 0.0992 0.00 8258.85 501.15
BANQUET_FLR_6 1.1437 0.0000 1.1437 0.0149 1.1586 1.1878 6013.43 202.43 2544.14
DINING_FLR_6 1.2335 0.0000 1.2335 0.0149 1.2483 1.1878 4879.89 224.94 3655.17
KITCHEN_FLR_6 1.6757 0.0000 1.6757 0.0133 1.6890 0.3674 0.00 0.00 8760.00
CORRIDOR_FLR_6 0.3911 0.0000 0.3911 0.0131 0.4042 0.1256 0.00 0.00 8760.00
Total Facility 80.0384 0.1074 80.1458 0.4853 80.6311 73.9670 8760.00 8307.70 8760.00


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
VAV WITH REHEAT 0.54E+09 0.00 0.54E+09 0.22E+09 0.00 0.00 8760.00 0.00
FLR_3_DOAS 90907156.64 309720.28 91216876.92 64690340.46 0.00 0.00 8760.00 0.00


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
VAV WITH REHEAT 17.0481 0.0000 17.0481 6.9969 0.00 0.00 8760.00
FLR_3_DOAS 2.8826 0.0098 2.8925 2.0513 0.00 0.00 8760.00


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
VAV WITH REHEAT 0.00 5917.83 2003.08 0.00 839.09 0.00 0.00 0.00 0.00 0.00
FLR_3_DOAS 0.00 8760.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
VAV WITH REHEAT 0.0000 16.3898 19.2823 0.0000 16.3773 0.0000 0.0000 0.0000 0.0000 0.0000
FLR_3_DOAS 0.0000 2.8826 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Surfaces by Class

Total Outdoors
Wall 119 44
Floor 25 0
Roof 33 11
Internal Mass 22 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 30 30
Door 6 6
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 2
Conditioned Zones 22
Unconditioned Zones 0
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1318
Defaulted Fields 1181
Fields with Defaults 4005
Autosized Fields 350
Autosizable Fields 402
Autocalculated Fields 280
Autocalculatable Fields 539



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
Electricity:Building 2518.68 32511.05 06-MAY-05:00 151906.32 02-JAN-20:10
Electricity:Zone:BASEMENT 323.72 3705.45 02-JAN-02:10 24299.15 02-JAN-20:10
Electricity:SpaceType:GENERAL 2511.59 32369.91 06-MAY-05:00 151664.99 02-JAN-20:10
InteriorLights:Electricity 766.57 6678.11 06-MAY-05:00 62892.57 02-JAN-20:10
InteriorLights:Electricity:Zone:BASEMENT 173.46 1576.23 02-JAN-02:10 14185.34 02-JAN-20:10
InteriorLights:Electricity:SpaceType:GENERAL 766.57 6678.11 06-MAY-05:00 62892.57 02-JAN-20:10
LightsWired:InteriorLights:Electricity 766.57 6678.11 06-MAY-05:00 62892.57 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:BASEMENT 173.46 1576.23 02-JAN-02:10 14185.34 02-JAN-20:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 766.57 6678.11 06-MAY-05:00 62892.57 02-JAN-20:10
Electricity:Zone:RETAIL_1_FLR_1 18.80 222.61 02-JAN-02:10 1390.02 02-JAN-20:10
InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 8.61 78.27 02-JAN-02:10 704.41 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 8.61 78.27 02-JAN-02:10 704.41 02-JAN-20:10
Electricity:Zone:RETAIL_2_FLR_1 21.77 257.78 02-JAN-02:10 1609.65 02-JAN-20:10
InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 9.97 90.64 02-JAN-02:10 815.72 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 9.97 90.64 02-JAN-02:10 815.72 02-JAN-20:10
Electricity:Zone:MECH_FLR_1 29.11 327.88 02-JAN-02:10 2199.84 02-JAN-20:10
InteriorLights:Electricity:Zone:MECH_FLR_1 16.64 151.16 02-JAN-02:10 1360.40 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:MECH_FLR_1 16.64 151.16 02-JAN-02:10 1360.40 02-JAN-20:10
Electricity:Zone:STORAGE_FLR_1 6.38 76.28 02-JAN-02:10 469.87 02-JAN-20:10
InteriorLights:Electricity:Zone:STORAGE_FLR_1 2.78 25.30 02-JAN-02:10 227.72 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:STORAGE_FLR_1 2.78 25.30 02-JAN-02:10 227.72 02-JAN-20:10
Electricity:Zone:LAUNDRY_FLR_1 72.30 1002.39 02-JAN-02:10 4930.01 02-JAN-20:10
InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 4.37 39.69 02-JAN-02:10 357.21 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 4.37 39.69 02-JAN-02:10 357.21 02-JAN-20:10
Electricity:Zone:CAFE_FLR_1 32.26 322.63 06-MAY-04:50 2727.18 02-JAN-20:10
InteriorLights:Electricity:Zone:CAFE_FLR_1 17.92 119.42 06-MAY-04:50 1761.91 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:CAFE_FLR_1 17.92 119.42 06-MAY-04:50 1761.91 02-JAN-20:10
Electricity:Zone:LOBBY_FLR_1 270.90 3172.15 06-MAY-05:00 20294.39 02-JAN-20:10
InteriorLights:Electricity:Zone:LOBBY_FLR_1 121.90 1060.74 06-MAY-05:00 10265.18 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:LOBBY_FLR_1 121.90 1060.74 06-MAY-05:00 10265.18 02-JAN-20:10
Electricity:Zone:ROOM_1_FLR_3 18.66 264.62 01-JAN-02:10 1227.54 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_1_FLR_3 6.37 53.90 01-JAN-02:10 490.02 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_3 6.37 53.90 01-JAN-02:10 490.02 01-JAN-19:10
Electricity:Zone:ROOM_2_FLR_3 18.66 264.59 01-JAN-02:10 1227.39 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_2_FLR_3 6.37 53.89 01-JAN-02:10 489.96 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_3 6.37 53.89 01-JAN-02:10 489.96 01-JAN-19:10
Electricity:Zone:ROOM_3_MULT19_FLR_3 304.77 4565.05 01-JAN-02:10 20923.25 01-JAN-08:10
InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 76.02 643.59 01-JAN-02:10 5851.22 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 76.02 643.59 01-JAN-02:10 5851.22 01-JAN-19:10
Electricity:Zone:ROOM_4_MULT19_FLR_3 304.86 4566.30 01-JAN-02:10 20928.98 01-JAN-08:10
InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 76.04 643.77 01-JAN-02:10 5852.82 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 76.04 643.77 01-JAN-02:10 5852.82 01-JAN-19:10
Electricity:Zone:ROOM_5_FLR_3 18.66 264.62 01-JAN-02:10 1227.54 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_5_FLR_3 6.37 53.90 01-JAN-02:10 490.02 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_5_FLR_3 6.37 53.90 01-JAN-02:10 490.02 01-JAN-19:10
Electricity:Zone:ROOM_6_FLR_3 18.66 264.59 01-JAN-02:10 1227.39 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_6_FLR_3 6.37 53.89 01-JAN-02:10 489.96 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_6_FLR_3 6.37 53.89 01-JAN-02:10 489.96 01-JAN-19:10
Electricity:Zone:CORRIDOR_FLR_3 109.60 995.90 02-JAN-02:10 8963.13 02-JAN-20:10
InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 109.60 995.90 02-JAN-02:10 8963.13 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 109.60 995.90 02-JAN-02:10 8963.13 02-JAN-20:10
Electricity:Zone:ROOM_1_FLR_6 4.66 66.15 01-JAN-02:10 306.88 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_1_FLR_6 1.59 13.47 01-JAN-02:10 122.50 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_6 1.59 13.47 01-JAN-02:10 122.50 01-JAN-19:10
Electricity:Zone:ROOM_2_FLR_6 4.66 66.15 01-JAN-02:10 306.85 01-JAN-21:10
InteriorLights:Electricity:Zone:ROOM_2_FLR_6 1.59 13.47 01-JAN-02:10 122.49 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_6 1.59 13.47 01-JAN-02:10 122.49 01-JAN-19:10
Electricity:Zone:ROOM_3_MULT9_FLR_6 36.10 540.75 01-JAN-02:10 2478.43 01-JAN-08:10
InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 9.00 76.24 01-JAN-02:10 693.10 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 9.00 76.24 01-JAN-02:10 693.10 01-JAN-19:10
Electricity:Zone:BANQUET_FLR_6 210.50 2524.33 06-MAY-04:40 9841.96 02-JAN-20:10
InteriorLights:Electricity:Zone:BANQUET_FLR_6 34.64 275.03 06-MAY-04:40 3094.06 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:BANQUET_FLR_6 34.64 275.03 06-MAY-04:40 3094.06 02-JAN-20:10
Electricity:Zone:DINING_FLR_6 210.50 2524.33 06-MAY-04:40 9841.96 02-JAN-20:10
InteriorLights:Electricity:Zone:DINING_FLR_6 34.64 275.03 06-MAY-04:40 3094.06 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:DINING_FLR_6 34.64 275.03 06-MAY-04:40 3094.06 02-JAN-20:10
Electricity:Zone:KITCHEN_FLR_6 454.16 6253.02 02-JAN-02:10 18944.06 01-JAN-11:10
InteriorLights:Electricity:Zone:KITCHEN_FLR_6 13.33 121.09 02-JAN-02:10 1089.83 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:KITCHEN_FLR_6 13.33 121.09 02-JAN-02:10 1089.83 02-JAN-20:10
Electricity:Zone:CORRIDOR_FLR_6 29.00 263.50 02-JAN-02:10 2371.52 02-JAN-20:10
InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 29.00 263.50 02-JAN-02:10 2371.52 02-JAN-20:10
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 29.00 263.50 02-JAN-02:10 2371.52 02-JAN-20:10
InteriorEquipment:Electricity 1745.01 25691.80 02-JAN-02:10 89475.41 02-JAN-07:10
InteriorEquipment:Electricity:Zone:BASEMENT 150.26 2129.22 02-JAN-02:10 10113.80 02-JAN-20:10
InteriorEquipment:Electricity:SpaceType:GENERAL 1745.01 25691.80 02-JAN-02:10 89475.41 02-JAN-07:10
MiscPlug:InteriorEquipment:Electricity 959.56 15202.41 02-JAN-02:10 59492.27 02-JAN-07:10
MiscPlug:InteriorEquipment:Electricity:Zone:BASEMENT 150.26 2129.22 02-JAN-02:10 10113.80 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 959.56 15202.41 02-JAN-02:10 59492.27 02-JAN-07:10
InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 10.19 144.34 02-JAN-02:10 685.60 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 10.19 144.34 02-JAN-02:10 685.60 02-JAN-20:10
InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 11.79 167.14 02-JAN-02:10 793.93 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 11.79 167.14 02-JAN-02:10 793.93 02-JAN-20:10
InteriorEquipment:Electricity:Zone:MECH_FLR_1 12.47 176.73 02-JAN-02:10 839.45 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:MECH_FLR_1 12.47 176.73 02-JAN-02:10 839.45 02-JAN-20:10
InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 3.60 50.98 02-JAN-02:10 242.16 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 3.60 50.98 02-JAN-02:10 242.16 02-JAN-20:10
InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 67.94 962.69 02-JAN-02:10 4572.80 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 67.94 962.69 02-JAN-02:10 4572.80 02-JAN-20:10
InteriorEquipment:Electricity:Zone:CAFE_FLR_1 14.34 203.22 02-JAN-02:10 965.27 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:CAFE_FLR_1 14.34 203.22 02-JAN-02:10 965.27 02-JAN-20:10
InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 149.00 2111.41 02-JAN-02:10 10029.21 02-JAN-20:10
MiscPlug:InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 149.00 2111.41 02-JAN-02:10 10029.21 02-JAN-20:10
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 12.29 210.72 01-JAN-00:10 948.23 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 12.29 210.72 01-JAN-00:10 948.23 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 12.29 210.69 01-JAN-00:10 948.12 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 12.29 210.69 01-JAN-00:10 948.12 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 228.75 3921.46 01-JAN-00:10 17646.57 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 228.75 3921.46 01-JAN-00:10 17646.57 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 228.82 3922.53 01-JAN-00:10 17651.40 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 228.82 3922.53 01-JAN-00:10 17651.40 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 12.29 210.72 01-JAN-00:10 948.23 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 12.29 210.72 01-JAN-00:10 948.23 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 12.29 210.69 01-JAN-00:10 948.12 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 12.29 210.69 01-JAN-00:10 948.12 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 3.07 52.68 01-JAN-00:10 237.06 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 3.07 52.68 01-JAN-00:10 237.06 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 3.07 52.67 01-JAN-00:10 237.03 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 3.07 52.67 01-JAN-00:10 237.03 01-JAN-08:10
InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 27.10 464.51 01-JAN-00:10 2090.30 01-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 27.10 464.51 01-JAN-00:10 2090.30 01-JAN-08:10
InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 175.86 2249.30 01-JAN-00:10 6747.90 01-JAN-07:10
Cooking:InteriorEquipment:Electricity 762.04 9746.88 01-JAN-00:10 29240.64 01-JAN-07:10
Cooking:InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 175.86 2249.30 01-JAN-00:10 6747.90 01-JAN-07:10
Cooking:InteriorEquipment:Electricity:SpaceType:GENERAL 762.04 9746.88 01-JAN-00:10 29240.64 01-JAN-07:10
InteriorEquipment:Electricity:Zone:DINING_FLR_6 175.86 2249.30 01-JAN-00:10 6747.90 01-JAN-07:10
Cooking:InteriorEquipment:Electricity:Zone:DINING_FLR_6 175.86 2249.30 01-JAN-00:10 6747.90 01-JAN-07:10
InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 433.74 5990.78 01-JAN-00:10 16487.34 01-JAN-07:10
Cooking:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 410.33 5248.28 01-JAN-00:10 15744.84 01-JAN-07:10
ReachInFreezer:InteriorEquipment:Electricity 14.43 457.50 01-JAN-00:10 457.50 01-JAN-00:10
ReachInFreezer:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 14.43 457.50 01-JAN-00:10 457.50 01-JAN-00:10
ReachInFreezer:InteriorEquipment:Electricity:SpaceType:GENERAL 14.43 457.50 01-JAN-00:10 457.50 01-JAN-00:10
ReachInRefrigerator:InteriorEquipment:Electricity 8.99 285.00 01-JAN-00:10 285.00 01-JAN-00:10
ReachInRefrigerator:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 8.99 285.00 01-JAN-00:10 285.00 01-JAN-00:10
ReachInRefrigerator:InteriorEquipment:Electricity:SpaceType:GENERAL 8.99 285.00 01-JAN-00:10 285.00 01-JAN-00:10
Refrigeration:Electricity 60.99 1026.99 11-JAN-23:30 3424.31 22-AUG-05:50
Refrigeration:Electricity:Zone:KITCHEN_FLR_6 7.09 88.82 02-JAN-11:30 2093.44 01-JAN-11:10
General:Refrigeration:Electricity 7.09 88.82 02-JAN-11:30 2093.44 01-JAN-11:10
General:Refrigeration:Electricity:Zone:KITCHEN_FLR_6 7.09 88.82 02-JAN-11:30 2093.44 01-JAN-11:10
Electricity:Plant 573.19 2589.27 05-MAY-02:50 134175.66 29-JUL-15:10
LowTempRefrigeration:Refrigeration:Electricity 20.30 0.00 01-JAN-11:10 2024.18 22-AUG-05:50
MedTempRefrigeration:Refrigeration:Electricity 33.60 866.91 12-JAN-04:00 1245.48 02-OCT-08:30
Fans:Electricity 553.69 12198.26 04-SEP-04:40 45649.25 21-AUG-00:50
Fans:Electricity:Zone:ROOM_1_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_2_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_5_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_5_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_6_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_6_FLR_3 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_1_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_2_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Electricity:HVAC 831.90 14562.96 13-AUG-02:30 47737.87 21-AUG-00:50
ExteriorEquipment:Electricity 651.48 9618.52 16-JUN-03:00 39726.11 02-JAN-07:20
Transformer:ExteriorEquipment:Electricity 32.45 553.70 20-MAY-04:50 1868.65 05-OCT-20:10
ElectricityPurchased:Facility 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
ElectricityPurchased:Plant 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
Cogeneration:ElectricityPurchased 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
General:Cogeneration:ElectricityPurchased 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
ElectricityNet:Plant 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
Cogeneration:ElectricityNet 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
General:Cogeneration:ElectricityNet 4783.66 69571.27 27-MAY-04:00 337827.26 20-JUN-19:10
General:Fans:Electricity 553.69 12198.26 04-SEP-04:40 45649.25 21-AUG-00:50
ExteriorLights:Electricity 240.86 0.00 01-JAN-11:20 15448.40 01-JAN-00:10
General:ExteriorLights:Electricity 240.86 0.00 01-JAN-11:20 15448.40 01-JAN-00:10
ElevatorLift:ExteriorEquipment:Electricity 616.11 9046.01 01-JAN-00:10 37691.69 01-JAN-07:10
ElevatorLightsFan:ExteriorEquipment:Electricity 2.91 18.80 01-JAN-00:10 188.00 01-JAN-07:10
HeatRecovery:Electricity 245.76 0.00 22-APR-12:40 9938.94 20-MAR-10:40
General:HeatRecovery:Electricity 245.76 0.00 22-APR-12:40 9938.94 20-MAR-10:40
WaterSystems:Electricity 90.75 1086.56 23-JUN-00:40 4739.94 12-JAN-08:00
Water Heater:WaterSystems:Electricity 90.75 1086.56 23-JUN-00:40 4739.94 12-JAN-08:00
Heating:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:Electricity 326.86 0.00 01-JAN-00:10 122158.15 29-JUL-15:10
General:Cooling:Electricity 326.86 0.00 01-JAN-00:10 122158.15 29-JUL-15:10
Pumps:Electricity 101.67 47.91 04-OCT-11:10 7970.73 10-JUL-18:10
General:Pumps:Electricity 101.67 47.91 04-OCT-11:10 7970.73 10-JUL-18:10
WIRED_LTG_ELECTRICITY 26.98 0.00 01-JAN-00:10 2213.82 02-JAN-20:20


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 10837.03 29270.80 31-MAY-01:10 1597257.76 12-JAN-18:00
NaturalGas:Building 1788.84 13361.90 02-JAN-02:10 104248.32 02-JAN-18:10
NaturalGas:Zone:LAUNDRY_FLR_1 590.20 8363.49 02-JAN-02:10 39726.58 02-JAN-20:10
NaturalGas:SpaceType:GENERAL 1788.84 13361.90 02-JAN-02:10 104248.32 02-JAN-18:10
InteriorEquipment:NaturalGas 1788.84 13361.90 02-JAN-02:10 104248.32 02-JAN-18:10
InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 590.20 8363.49 02-JAN-02:10 39726.58 02-JAN-20:10
InteriorEquipment:NaturalGas:SpaceType:GENERAL 1788.84 13361.90 02-JAN-02:10 104248.32 02-JAN-18:10
Laundry:InteriorEquipment:NaturalGas 590.20 8363.49 02-JAN-02:10 39726.58 02-JAN-20:10
Laundry:InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 590.20 8363.49 02-JAN-02:10 39726.58 02-JAN-20:10
Laundry:InteriorEquipment:NaturalGas:SpaceType:GENERAL 590.20 8363.49 02-JAN-02:10 39726.58 02-JAN-20:10
NaturalGas:Zone:KITCHEN_FLR_6 1198.64 4998.41 01-JAN-00:10 74976.11 01-JAN-16:10
InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 1198.64 4998.41 01-JAN-00:10 74976.11 01-JAN-16:10
Cooking:InteriorEquipment:NaturalGas 1198.64 4998.41 01-JAN-00:10 74976.11 01-JAN-16:10
Cooking:InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 1198.64 4998.41 01-JAN-00:10 74976.11 01-JAN-16:10
Cooking:InteriorEquipment:NaturalGas:SpaceType:GENERAL 1198.64 4998.41 01-JAN-00:10 74976.11 01-JAN-16:10
NaturalGas:Plant 9048.19 15908.90 27-JUL-10:10 1507645.54 12-JAN-18:00
WaterSystems:NaturalGas 3627.82 15908.90 13-JAN-11:10 312653.98 18-APR-20:20
Water Heater:WaterSystems:NaturalGas 3627.82 15908.90 13-JAN-11:10 312653.98 18-APR-20:20
Heating:NaturalGas 5420.38 0.00 11-APR-17:40 1290744.00 12-JAN-09:20
Boiler:Heating:NaturalGas 5420.38 0.00 11-APR-17:40 1290744.00 12-JAN-09:20


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
PlantLoopCoolingDemand:Facility 1005.42 0.00 01-JAN-00:10 415012.98 29-JUL-18:10
PlantLoopCoolingDemand:HVAC 1005.42 0.00 01-JAN-00:10 415012.98 29-JUL-18:10
CoolingCoils:PlantLoopCoolingDemand 1005.42 0.00 01-JAN-00:10 415012.98 29-JUL-18:10


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
Water:Plant 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
WaterSystems:Water 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
Water Heater:WaterSystems:Water 5742.51 0.00 01-MAY-01:10 0.00 02-JAN-19:10
MainsWater:Facility 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
MainsWater:Plant 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
WaterSystems:MainsWater 9857.19 0.00 02-JAN-01:10 0.00 12-APR-20:10
Water Heater:WaterSystems:MainsWater 5742.51 0.00 01-MAY-01:10 0.00 02-JAN-19:10
WaterUse:WaterSystems:Water 4114.69 0.00 02-JAN-01:10 0.00 30-JAN-07:10
WaterUse:WaterSystems:MainsWater 4114.69 0.00 02-JAN-01:10 0.00 30-JAN-07:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 24709.44 157990.86 01-OCT-15:00 2403763.98 12-JAN-09:20
EnergyTransfer:Building 5299.78 68619.43 02-OCT-08:20 345107.40 11-JUL-18:20
EnergyTransfer:Zone:KITCHEN_FLR_6 678.70 7373.84 13-JAN-04:00 37829.37 22-JUL-10:50
Refrigeration:EnergyTransfer 178.32 3490.67 11-JAN-23:10 10617.04 01-SEP-06:40
Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 89.16 1745.34 11-JAN-23:10 5308.52 01-SEP-06:40
General:Refrigeration:EnergyTransfer 89.16 1745.34 11-JAN-23:10 5308.52 01-SEP-06:40
General:Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 89.16 1745.34 11-JAN-23:10 5308.52 01-SEP-06:40
EnergyTransfer:Plant 7806.89 19870.01 08-SEP-03:00 1097611.81 12-JAN-09:20
LowTempRefrigeration:Refrigeration:EnergyTransfer 21.48 0.00 01-JAN-11:10 2686.44 01-JAN-11:40
MedTempRefrigeration:Refrigeration:EnergyTransfer 67.68 1550.74 12-JAN-04:00 2686.44 02-OCT-08:30
EnergyTransfer:Zone:BASEMENT 362.94 1396.51 22-APR-23:00 23228.29 05-SEP-20:00
Heating:EnergyTransfer 986.42 0.00 18-MAR-17:40 196286.26 12-JAN-16:10
Heating:EnergyTransfer:Zone:BASEMENT 0.05 0.00 01-JAN-00:10 1271.10 22-MAR-14:30
General:Heating:EnergyTransfer 986.42 0.00 18-MAR-17:40 196286.26 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:BASEMENT 0.05 0.00 01-JAN-00:10 1271.10 22-MAR-14:30
Cooling:EnergyTransfer 4224.21 41406.07 13-JAN-15:00 342439.77 11-JUL-18:20
Cooling:EnergyTransfer:Zone:BASEMENT 362.89 1396.51 22-APR-23:00 23228.29 05-SEP-20:00
General:Cooling:EnergyTransfer 4224.21 41406.07 13-JAN-15:00 342439.77 11-JUL-18:20
General:Cooling:EnergyTransfer:Zone:BASEMENT 362.89 1396.51 22-APR-23:00 23228.29 05-SEP-20:00
EnergyTransfer:Zone:RETAIL_1_FLR_1 48.71 0.20 09-MAR-22:30 5305.74 25-AUG-13:30
Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 15.86 0.00 23-JAN-11:50 3202.58 13-JAN-10:50
General:Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 15.86 0.00 23-JAN-11:50 3202.58 13-JAN-10:50
Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 32.86 0.00 01-JAN-00:10 5305.74 25-AUG-13:30
General:Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 32.86 0.00 01-JAN-00:10 5305.74 25-AUG-13:30
EnergyTransfer:Zone:RETAIL_2_FLR_1 26.98 0.07 16-JAN-15:30 2002.78 21-JUN-21:00
Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 0.13 0.00 01-JAN-00:10 468.37 13-JAN-11:00
General:Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 0.13 0.00 01-JAN-00:10 468.37 13-JAN-11:00
Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 26.85 0.00 01-JAN-13:10 2002.78 21-JUN-21:00
General:Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 26.85 0.00 01-JAN-13:10 2002.78 21-JUN-21:00
EnergyTransfer:Zone:MECH_FLR_1 22.99 0.01 28-MAR-07:00 1743.93 12-JUL-20:00
Heating:EnergyTransfer:Zone:MECH_FLR_1 6.22 0.00 01-JAN-20:40 1621.92 12-JAN-16:00
General:Heating:EnergyTransfer:Zone:MECH_FLR_1 6.22 0.00 01-JAN-20:40 1621.92 12-JAN-16:00
Cooling:EnergyTransfer:Zone:MECH_FLR_1 16.77 0.00 01-JAN-00:10 1743.93 12-JUL-20:00
General:Cooling:EnergyTransfer:Zone:MECH_FLR_1 16.77 0.00 01-JAN-00:10 1743.93 12-JUL-20:00
EnergyTransfer:Zone:STORAGE_FLR_1 14.03 0.01 03-APR-18:50 1203.70 13-JAN-10:50
Heating:EnergyTransfer:Zone:STORAGE_FLR_1 6.85 0.00 07-FEB-20:30 1203.70 13-JAN-10:50
General:Heating:EnergyTransfer:Zone:STORAGE_FLR_1 6.85 0.00 07-FEB-20:30 1203.70 13-JAN-10:50
Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 7.18 0.00 01-JAN-00:10 682.21 23-JUL-10:40
General:Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 7.18 0.00 01-JAN-00:10 682.21 23-JUL-10:40
EnergyTransfer:Zone:LAUNDRY_FLR_1 569.43 6904.49 28-AUG-04:00 39162.92 05-SEP-20:00
Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 0.01 0.00 01-JAN-00:10 543.70 02-OCT-03:40
General:Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 0.01 0.00 01-JAN-00:10 543.70 02-OCT-03:40
Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 569.42 6904.49 28-AUG-04:00 39162.92 05-SEP-20:00
General:Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 569.42 6904.49 28-AUG-04:00 39162.92 05-SEP-20:00
EnergyTransfer:Zone:CAFE_FLR_1 204.51 3.24 26-FEB-08:50 17830.39 25-AUG-14:10
Heating:EnergyTransfer:Zone:CAFE_FLR_1 4.94 0.00 01-JAN-00:10 5428.05 15-DEC-15:00
General:Heating:EnergyTransfer:Zone:CAFE_FLR_1 4.94 0.00 01-JAN-00:10 5428.05 15-DEC-15:00
Cooling:EnergyTransfer:Zone:CAFE_FLR_1 199.57 0.00 01-JAN-11:10 17830.39 25-AUG-14:10
General:Cooling:EnergyTransfer:Zone:CAFE_FLR_1 199.57 0.00 01-JAN-11:10 17830.39 25-AUG-14:10
EnergyTransfer:Zone:LOBBY_FLR_1 666.72 4.37 06-DEC-15:50 41408.95 21-JUL-21:10
Heating:EnergyTransfer:Zone:LOBBY_FLR_1 0.52 0.00 01-JAN-00:10 5809.19 13-JAN-10:50
General:Heating:EnergyTransfer:Zone:LOBBY_FLR_1 0.52 0.00 01-JAN-00:10 5809.19 13-JAN-10:50
Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 666.21 0.00 03-JAN-10:40 41408.95 21-JUL-21:10
General:Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 666.21 0.00 03-JAN-10:40 41408.95 21-JUL-21:10
EnergyTransfer:Zone:ROOM_1_FLR_3 101.51 0.51 18-APR-23:50 12455.56 11-JUL-18:10
Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 67.00 0.00 07-JAN-08:10 11987.60 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 67.00 0.00 07-JAN-08:10 11987.60 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 34.51 0.00 01-JAN-00:10 12455.56 11-JUL-18:10
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 34.51 0.00 01-JAN-00:10 12455.56 11-JUL-18:10
EnergyTransfer:Zone:ROOM_2_FLR_3 100.43 0.26 03-MAY-06:00 12133.86 12-JAN-16:10
Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 73.76 0.00 07-JAN-08:10 12133.86 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 73.76 0.00 07-JAN-08:10 12133.86 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 26.67 0.00 01-JAN-00:10 11502.26 19-JUN-18:10
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 26.67 0.00 01-JAN-00:10 11502.26 19-JUN-18:10
EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 524.58 3.63 10-FEB-21:50 75052.77 25-AUG-13:30
Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 215.04 0.00 23-JAN-12:10 44093.74 12-JAN-04:10
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 215.04 0.00 23-JAN-12:10 44093.74 12-JAN-04:10
Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 309.54 0.00 01-JAN-00:10 75052.77 25-AUG-13:30
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 309.54 0.00 01-JAN-00:10 75052.77 25-AUG-13:30
EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 512.85 1.79 22-JAN-15:50 69916.87 13-JAN-16:20
Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 274.82 0.00 01-JAN-08:10 69916.87 13-JAN-16:20
General:Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 274.82 0.00 01-JAN-08:10 69916.87 13-JAN-16:20
Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 238.03 0.00 01-JAN-00:10 59738.29 22-JUN-15:20
General:Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 238.03 0.00 01-JAN-00:10 59738.29 22-JUN-15:20
EnergyTransfer:Zone:ROOM_5_FLR_3 105.78 0.21 16-OCT-13:30 12397.06 22-JUL-08:10
Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 64.29 0.00 07-JAN-08:10 11917.93 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 64.29 0.00 07-JAN-08:10 11917.93 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 41.49 0.00 01-JAN-00:10 12397.06 22-JUL-08:10
General:Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 41.49 0.00 01-JAN-00:10 12397.06 22-JUL-08:10
EnergyTransfer:Zone:ROOM_6_FLR_3 103.32 0.40 16-OCT-11:20 12049.07 12-JAN-16:10
Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 70.54 0.00 07-JAN-08:10 12049.07 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 70.54 0.00 07-JAN-08:10 12049.07 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 32.78 0.00 01-JAN-00:10 11496.84 22-JUL-08:10
General:Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 32.78 0.00 01-JAN-00:10 11496.84 22-JUL-08:10
EnergyTransfer:Zone:CORRIDOR_FLR_3 160.54 0.06 19-JAN-06:40 11858.93 11-JUL-20:40
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 28.36 0.00 02-JAN-22:10 9523.55 15-DEC-15:00
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 28.36 0.00 02-JAN-22:10 9523.55 15-DEC-15:00
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 132.19 0.00 01-JAN-00:10 11858.93 11-JUL-20:40
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 132.19 0.00 01-JAN-00:10 11858.93 11-JUL-20:40
EnergyTransfer:Zone:ROOM_1_FLR_6 30.73 0.01 25-JUN-03:40 3713.92 12-JAN-16:10
Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 22.74 0.00 07-FEB-11:10 3713.92 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 22.74 0.00 07-FEB-11:10 3713.92 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 7.99 0.00 01-JAN-00:10 3256.81 11-JUL-18:10
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 7.99 0.00 01-JAN-00:10 3256.81 11-JUL-18:10
EnergyTransfer:Zone:ROOM_2_FLR_6 30.81 0.03 04-MAY-09:20 3741.24 12-JAN-16:10
Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 24.85 0.00 09-FEB-08:10 3741.24 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 24.85 0.00 09-FEB-08:10 3741.24 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 5.96 0.00 01-JAN-00:10 3014.57 11-JUL-18:10
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 5.96 0.00 01-JAN-00:10 3014.57 11-JUL-18:10
EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 144.78 0.59 14-SEP-04:30 21142.49 10-AUG-15:10
Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 80.88 0.00 07-JAN-08:10 17042.23 12-JAN-16:10
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 80.88 0.00 07-JAN-08:10 17042.23 12-JAN-16:10
Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 63.90 0.00 01-JAN-00:10 21142.49 10-AUG-15:10
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 63.90 0.00 01-JAN-00:10 21142.49 10-AUG-15:10
EnergyTransfer:Zone:BANQUET_FLR_6 380.07 2571.80 12-JAN-15:00 23668.85 11-JUL-21:10
Heating:EnergyTransfer:Zone:BANQUET_FLR_6 0.00 0.00 01-JAN-00:10 45.72 02-OCT-09:00
General:Heating:EnergyTransfer:Zone:BANQUET_FLR_6 0.00 0.00 01-JAN-00:10 45.72 02-OCT-09:00
Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 380.07 2571.80 12-JAN-15:00 23668.85 11-JUL-21:10
General:Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 380.07 2571.80 12-JAN-15:00 23668.85 11-JUL-21:10
EnergyTransfer:Zone:DINING_FLR_6 418.80 3508.57 12-JAN-15:00 24898.44 11-JUL-21:10
Heating:EnergyTransfer:Zone:DINING_FLR_6 0.00 0.00 01-JAN-00:10 4.95 02-OCT-09:00
General:Heating:EnergyTransfer:Zone:DINING_FLR_6 0.00 0.00 01-JAN-00:10 4.95 02-OCT-09:00
Cooling:EnergyTransfer:Zone:DINING_FLR_6 418.80 3508.57 12-JAN-15:00 24898.44 11-JUL-21:10
General:Cooling:EnergyTransfer:Zone:DINING_FLR_6 418.80 3508.57 12-JAN-15:00 24898.44 11-JUL-21:10
Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 589.54 5444.71 13-JAN-04:00 32763.69 22-JUL-10:50
General:Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 589.54 5444.71 13-JAN-04:00 32763.69 22-JUL-10:50
EnergyTransfer:Zone:CORRIDOR_FLR_6 90.54 0.06 02-FEB-20:30 7124.32 23-JUL-13:40
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 29.56 0.00 06-JAN-22:50 6961.76 12-JAN-16:00
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 29.56 0.00 06-JAN-22:50 6961.76 12-JAN-16:00
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 60.98 0.00 01-JAN-00:10 7124.32 23-JUL-13:40
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 60.98 0.00 01-JAN-00:10 7124.32 23-JUL-13:40
PlantLoopHeatingDemand:Facility 5270.26 12316.11 26-AUG-00:10 1103735.10 12-JAN-09:10
PlantLoopHeatingDemand:Plant 971.99 12243.59 12-SEP-00:40 67261.51 27-JAN-07:10
WaterSystems:PlantLoopHeatingDemand 971.99 12243.59 12-SEP-00:40 67261.51 27-JAN-07:10
General:WaterSystems:PlantLoopHeatingDemand 971.99 12243.59 12-SEP-00:40 67261.51 27-JAN-07:10
EnergyTransfer:HVAC 11602.77 3005.61 19-SEP-14:30 1065054.65 12-JAN-09:10
HeatingCoils:EnergyTransfer 4298.26 0.00 11-APR-17:40 1065054.65 12-JAN-09:10
PlantLoopHeatingDemand:HVAC 4298.26 0.00 11-APR-17:40 1065054.65 12-JAN-09:10
HeatingCoils:PlantLoopHeatingDemand 4298.26 0.00 11-APR-17:40 1065054.65 12-JAN-09:10
CoolingCoils:EnergyTransfer 1005.42 0.00 01-JAN-00:10 415012.98 29-JUL-18:10
HeatRecoveryForHeating:EnergyTransfer 6296.90 0.00 03-JAN-07:40 597724.94 07-NOV-06:30
HeatRecoveryForCooling:EnergyTransfer 2.19 0.00 01-JAN-00:10 49919.76 29-JUL-16:00
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
WaterSystems:EnergyTransfer 971.99 12243.59 12-SEP-00:40 67261.51 27-JAN-07:10
WaterUse:WaterSystems:EnergyTransfer 971.99 12243.59 12-SEP-00:40 67261.51 27-JAN-07:10
Boilers:EnergyTransfer 4261.64 0.00 11-APR-17:40 1056435.83 12-JAN-09:20
Chillers:EnergyTransfer 1078.62 0.00 01-JAN-00:10 423195.06 29-JUL-18:10
HeatRejection:EnergyTransfer 1405.48 0.00 01-JAN-00:10 540126.22 29-JUL-18:10
General:HeatRejection:EnergyTransfer 1405.48 0.00 01-JAN-00:10 540126.22 29-JUL-18:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
BASEMENT 0.000 0.000 0.050 -362.896 0.000 0.000 142.448 173.462 150.255 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -103.320
RETAIL_1_FLR_1 0.000 0.000 15.856 -32.857 0.000 0.000 15.918 8.614 10.186 27.086 0.000 0.009 0.000 0.000 -17.775 0.000 -9.391 -17.645
RETAIL_2_FLR_1 0.000 0.000 0.126 -26.853 0.000 0.000 17.514 9.975 11.795 0.000 0.000 0.003 0.000 0.000 0.000 0.000 -3.733 -8.827
MECH_FLR_1 0.000 0.000 6.217 -16.775 0.000 0.000 3.786 16.635 12.471 0.000 0.000 0.008 0.000 0.000 0.000 0.000 -8.709 -13.634
STORAGE_FLR_1 0.000 0.000 6.851 -7.176 0.000 0.000 2.935 2.785 3.598 0.000 0.000 0.005 0.000 0.000 0.000 0.000 -4.999 -3.999
LAUNDRY_FLR_1 0.000 0.000 0.010 -569.420 0.000 0.000 11.247 4.368 658.131 0.000 0.000 0.012 0.000 0.000 0.000 0.000 -12.504 -91.844
CAFE_FLR_1 0.000 0.000 4.942 -199.572 0.000 0.000 201.970 17.917 14.341 75.587 0.000 0.016 0.000 0.000 -50.563 0.000 -21.189 -43.448
LOBBY_FLR_1 0.000 0.000 0.517 -666.212 0.000 0.000 578.813 121.897 148.998 99.172 0.000 0.043 0.000 0.000 -68.726 0.000 -61.787 -152.715
ROOM_1_FLR_3 76.205 -27.440 0.000 -16.272 0.000 0.000 9.802 6.366 12.292 41.674 0.000 0.082 0.000 0.000 -41.347 0.000 -21.974 -39.389
ROOM_2_FLR_3 83.424 -20.299 0.000 -16.032 0.000 0.000 9.824 6.366 12.291 26.525 0.000 0.085 0.000 0.000 -43.583 0.000 -21.885 -36.714
ROOM_3_MULT19_FLR_3 292.443 -163.322 0.000 -223.623 0.000 0.000 0.000 76.021 228.754 324.782 0.000 0.165 0.000 0.000 -217.356 0.000 -128.711 -189.154
ROOM_4_MULT19_FLR_3 389.045 -134.780 0.000 -217.472 0.000 0.000 186.675 76.042 228.817 81.524 0.000 1.048 0.000 0.000 -241.892 0.000 -121.612 -247.394
ROOM_5_FLR_3 73.253 -34.008 0.000 -16.451 0.000 0.000 9.786 6.366 12.292 51.386 0.000 0.083 0.000 0.000 -40.767 0.000 -22.043 -39.896
ROOM_6_FLR_3 79.926 -25.903 0.000 -16.258 0.000 0.000 9.805 6.366 12.291 35.779 0.000 0.085 0.000 0.000 -42.583 0.000 -21.967 -37.542
CORRIDOR_FLR_3 0.000 0.000 28.356 -132.187 0.000 0.000 119.525 109.603 0.000 43.504 0.000 0.021 0.000 0.000 -52.222 0.000 -26.885 -89.716
ROOM_1_FLR_6 25.177 -6.383 0.000 -4.043 0.000 0.000 2.453 1.592 3.073 10.407 0.000 0.022 0.000 0.000 -10.259 0.000 -5.516 -16.521
ROOM_2_FLR_6 27.398 -4.518 0.000 -3.986 0.000 0.000 2.458 1.591 3.073 6.633 0.000 0.022 0.000 0.000 -10.815 0.000 -5.496 -16.361
ROOM_3_MULT9_FLR_6 94.628 -51.030 0.000 -26.624 0.000 0.000 21.993 9.005 27.097 70.441 0.000 0.146 0.000 0.000 -47.288 0.000 -26.142 -72.225
BANQUET_FLR_6 0.000 0.000 0.000 -380.077 0.000 0.000 322.973 34.639 175.857 8.450 0.000 0.008 0.000 0.000 -29.705 0.000 -14.458 -117.687
DINING_FLR_6 0.000 0.000 0.000 -418.805 0.000 0.000 320.629 34.639 175.857 8.311 0.000 0.008 0.000 0.000 -30.256 0.000 -14.549 -75.834
KITCHEN_FLR_6 0.000 0.000 0.000 -589.527 0.000 0.000 28.659 13.327 550.372 24.966 0.000 0.008 4.297 0.000 -18.962 0.000 -13.139 -0.002
CORRIDOR_FLR_6 0.000 0.000 29.564 -60.979 0.000 0.000 31.811 28.999 0.000 21.859 0.000 0.008 0.000 0.000 -23.002 0.000 -11.885 -16.375
Total Facility 1141.499 -467.682 92.489 -4004.097 0.000 0.000 2051.022 766.573 2451.839 958.086 0.000 1.889 4.297 0.000 -987.103 0.000 -578.574 -1430.241


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
BASEMENT 06-SEP-23:52 0.00 0.00 0.00 -41204.26 0.00 0.00 6477.49 3152.28 3193.83 0.00 0.00 0.00 28380.67 0.00 -0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 13-APR-15:07 0.00 0.00 0.00 -7772.73 0.00 0.00 376.30 195.67 252.59 6260.01 0.00 0.00 922.22 0.00 -0.00 0.00 -234.06 0.00
RETAIL_2_FLR_1 20-APR-21:29 0.00 0.00 0.00 -2693.15 0.00 0.00 784.80 543.81 585.00 0.00 0.00 0.00 863.77 0.00 -0.00 0.00 -84.24 0.00
MECH_FLR_1 03-SEP-01:23 0.00 0.00 0.00 -1969.19 0.00 0.00 140.07 302.31 265.09 0.00 0.00 0.00 1435.50 0.00 -0.00 0.00 -173.77 0.00
STORAGE_FLR_1 28-AUG-04:42 0.00 0.00 0.00 -937.41 0.00 0.00 137.47 50.60 76.47 0.00 0.00 0.00 779.57 0.00 -0.00 0.00 -106.71 0.00
LAUNDRY_FLR_1 13-APR-20:27 0.00 0.00 0.00 -51664.42 0.00 0.00 439.95 317.52 41967.83 0.00 0.00 0.00 9292.16 0.00 -0.00 0.00 -353.04 0.00
CAFE_FLR_1 13-APR-15:07 0.00 0.00 0.00 -29194.68 0.00 0.00 4941.93 298.55 355.63 17599.52 0.00 0.00 6519.80 0.00 -0.00 0.00 -520.75 0.00
LOBBY_FLR_1 20-APR-21:29 0.00 0.00 0.00 -67036.82 0.00 0.00 26432.04 6843.46 7389.94 0.00 0.00 0.00 30226.21 0.00 -2476.26 0.00 -1378.56 0.00
ROOM_1_FLR_3 10-AUG-18:02 0.00 -14276.36 0.00 -731.80 0.00 0.00 335.50 436.12 516.26 9506.74 0.00 0.00 4222.61 0.00 -0.00 0.00 -9.07 0.00
ROOM_2_FLR_3 19-JUN-18:02 0.00 -12859.89 0.00 -737.72 0.00 0.00 335.50 436.07 516.20 10083.13 0.00 13.40 2213.31 0.00 -0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 25-AUG-13:30 0.00 -64408.69 0.00 -10647.30 0.00 0.00 0.00 1638.34 5097.90 98295.50 0.00 0.00 0.00 0.00 -0.00 0.00 -242.00 -29733.75
ROOM_4_MULT19_FLR_3 13-JUL-18:02 0.00 -66441.30 0.00 -10025.83 0.00 0.00 6410.20 5209.05 9610.21 7107.78 0.00 1960.99 46168.92 0.00 -0.00 0.00 0.00 0.00
ROOM_5_FLR_3 10-AUG-15:02 0.00 -13306.45 0.00 -729.79 0.00 0.00 235.29 137.21 273.93 5698.42 0.00 0.00 7729.71 0.00 -0.00 0.00 -38.32 0.00
ROOM_6_FLR_3 13-JUL-18:02 0.00 -11958.88 0.00 -718.97 0.00 0.00 335.50 436.07 516.20 1241.24 0.00 155.34 9993.51 0.00 -0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 18-MAY-00:52 0.00 0.00 0.00 -15325.53 0.00 0.00 5527.93 1493.85 0.00 0.00 0.00 0.00 10739.32 0.00 -1828.75 0.00 -606.83 0.00
ROOM_1_FLR_6 10-AUG-18:02 0.00 -3720.05 0.00 -182.98 0.00 0.00 83.88 109.03 129.07 2368.35 0.00 0.00 1217.57 0.00 -0.00 0.00 -4.87 0.00
ROOM_2_FLR_6 19-JUN-18:02 0.00 -3309.50 0.00 -184.28 0.00 0.00 83.88 109.02 129.05 2511.47 0.00 2.22 658.15 0.00 -0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 10-AUG-15:02 0.00 -22306.56 0.00 -1185.72 0.00 0.00 529.40 194.07 603.86 15151.94 0.00 0.00 7145.78 0.00 -0.00 0.00 -132.78 0.00
BANQUET_FLR_6 14-SEP-22:50 0.00 0.00 0.00 -35170.78 0.00 0.00 15538.83 1031.35 6747.90 0.00 0.00 0.00 13083.29 0.00 -910.75 0.00 -319.85 0.00
DINING_FLR_6 14-SEP-22:50 0.00 0.00 0.00 -38188.02 0.00 0.00 15517.25 1031.35 6747.90 0.00 0.00 0.00 16138.79 0.00 -927.37 0.00 -319.90 0.00
KITCHEN_FLR_6 23-APR-08:62 0.00 0.00 0.00 -40547.78 0.00 0.00 680.59 363.28 19261.50 4361.11 0.00 0.00 16145.72 0.00 -0.00 0.00 -264.42 0.00
CORRIDOR_FLR_6 18-MAY-00:52 0.00 0.00 0.00 -7295.99 0.00 0.00 1509.72 395.25 0.00 0.00 0.00 0.00 6448.65 0.00 -797.19 0.00 -260.45 0.00
Total Facility 10-AUG-15:02 0.00 -195548.34 0.00 -187315.72 0.00 0.00 53038.89 16768.37 77329.74 189631.89 0.00 746.54 47789.32 0.00 0.00 0.00 -2440.70 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
BASEMENT 22-MAR-14:30 0.00 0.00 2542.24 0.00 0.00 0.00 2573.06 3940.39 3726.14 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -12781.84
RETAIL_1_FLR_1 13-JAN-10:50 0.00 0.00 3202.59 0.00 0.00 0.00 183.12 195.67 252.59 0.00 0.00 0.00 0.00 0.00 -1528.68 0.00 -724.56 -1580.73
RETAIL_2_FLR_1 13-JAN-11:00 0.00 0.00 468.37 0.00 0.00 0.00 207.31 226.59 292.50 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -281.58 -913.19
MECH_FLR_1 12-JAN-16:00 0.00 0.00 1621.93 0.00 0.00 0.00 65.76 377.89 309.27 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -747.54 -1627.31
STORAGE_FLR_1 13-JAN-11:03 0.00 0.00 1206.26 0.00 0.00 0.00 33.72 63.26 89.22 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -384.00 -1008.45
LAUNDRY_FLR_1 07-JUN-03:18 0.00 0.00 2358.19 0.00 0.00 0.00 597.75 39.69 9326.18 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -249.98 -12071.83
CAFE_FLR_1 15-DEC-15:00 0.00 0.00 5428.12 0.00 0.00 0.00 2405.35 489.42 355.63 0.00 0.00 0.00 0.00 0.00 -4640.15 0.00 -1596.82 -2441.54
LOBBY_FLR_1 13-JAN-10:50 0.00 0.00 5809.13 0.00 0.00 0.00 6982.89 2651.84 3694.97 0.00 0.00 0.00 0.00 0.00 -5819.49 0.00 -4616.54 -8702.79
ROOM_1_FLR_3 26-NOV-16:01 15731.30 309.17 0.00 -309.17 0.00 0.00 163.33 161.71 305.54 0.00 0.00 0.00 0.00 0.00 -3098.23 0.00 -1357.10 -11906.56
ROOM_2_FLR_3 26-NOV-16:01 15334.20 305.00 0.00 -305.00 0.00 0.00 163.33 161.69 305.51 0.00 0.00 0.00 0.00 0.00 -3089.83 0.00 -1355.19 -11519.70
ROOM_3_MULT19_FLR_3 12-JAN-04:05 44096.94 27083.09 0.00 -27083.09 0.00 0.00 0.00 643.59 3921.46 0.00 0.00 0.00 0.00 0.00 -22740.90 0.00 -10112.31 -15808.78
ROOM_4_MULT19_FLR_3 26-NOV-16:01 83249.58 3809.03 0.00 -3809.03 0.00 0.00 3103.18 1931.47 5687.67 0.00 0.00 0.00 0.00 0.00 -16723.64 0.00 -7130.91 -70117.35
ROOM_5_FLR_3 26-NOV-16:01 15490.12 307.70 0.00 -307.70 0.00 0.00 163.33 161.71 305.54 0.00 0.00 0.00 0.00 0.00 -3097.44 0.00 -1356.46 -11666.81
ROOM_6_FLR_3 26-NOV-16:01 15098.07 303.60 0.00 -303.60 0.00 0.00 163.33 161.69 305.51 0.00 0.00 0.00 0.00 0.00 -3089.24 0.00 -1354.58 -11284.77
CORRIDOR_FLR_3 15-DEC-15:00 0.00 0.00 9523.57 0.00 0.00 0.00 1385.83 2489.76 0.00 0.00 0.00 0.00 0.00 0.00 -4788.32 0.00 -2045.58 -6565.26
ROOM_1_FLR_6 26-NOV-16:01 4602.11 78.07 0.00 -78.07 0.00 0.00 40.83 40.43 76.39 0.00 0.00 0.00 0.00 0.00 -764.79 0.00 -340.17 -3654.79
ROOM_2_FLR_6 26-NOV-16:01 4456.73 76.71 0.00 -76.71 0.00 0.00 40.83 40.42 76.38 0.00 0.00 0.00 0.00 0.00 -762.55 0.00 -339.56 -3512.26
ROOM_3_MULT9_FLR_6 13-JAN-19:01 23080.04 505.39 0.00 -505.39 0.00 0.00 943.21 616.86 1138.05 0.00 0.00 0.00 0.00 0.00 -3257.09 0.00 -1441.80 -21079.27
BANQUET_FLR_6 02-OCT-08:53 0.00 0.00 457.23 0.00 0.00 0.00 3784.18 1100.11 6747.90 0.00 0.00 0.00 0.00 0.00 -428.23 0.00 -303.86 -11357.32
DINING_FLR_6 02-OCT-08:53 0.00 0.00 49.54 0.00 0.00 0.00 3723.50 1100.11 6747.90 0.00 0.00 0.00 0.00 0.00 -453.20 0.00 -309.49 -10858.36
KITCHEN_FLR_6 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_6 12-JAN-16:00 0.00 0.00 6961.82 0.00 0.00 0.00 551.19 658.76 0.00 0.00 0.00 0.00 0.00 0.00 -2241.92 0.00 -1018.89 -4910.95
Total Facility 13-JAN-16:02 155566.48 69693.44 20910.41 -69693.44 0.00 0.00 62627.64 17502.63 77329.74 0.00 0.00 0.00 0.00 0.00 -71952.75 0.00 -35182.70 -226801.45



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
VAV WITH REHEAT 23.8294 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 23.6842 0.0000 1.0000 Not calculated 0.0000 0.0000    
FLR_3_DOAS 2.0513 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 2.0513 0.0000 1.0000 Not calculated 0.0000 0.0000    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
VAV WITH REHEAT 11.9147 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 11.6526 0.0000 1.0000 Not calculated 0.0000 0.0000    
FLR_3_DOAS 2.0513 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 2.0513 0.0000 1.0000 Not calculated 0.0000 0.0000    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
BASEMENT VAV WITH REHEAT 0.000000 106.4990 0.000432 1978.83 0.0000 1.0000 0.0000 1.000 0.0000
RETAIL_1_FLR_1 VAV WITH REHEAT 0.000000 10.8290 0.001181 67.07 0.0000 1.0000 0.0000 1.000 0.0000
RETAIL_2_FLR_1 VAV WITH REHEAT 0.000000 12.5400 0.001181 77.67 0.0000 1.0000 0.0000 1.000 0.0000
MECH_FLR_1 VAV WITH REHEAT 0.000000 2.6520 0.000000 164.24 0.0000 1.0000 0.0000 1.000 0.0000
STORAGE_FLR_1 VAV WITH REHEAT 0.000000 2.0400 0.000610 94.76 0.0000 1.0000 0.0000 1.000 0.0000
LAUNDRY_FLR_1 VAV WITH REHEAT 0.000000 8.4000 0.000000 78.04 0.0000 1.0000 0.0000 1.000 0.0000
CAFE_FLR_1 VAV WITH REHEAT 0.000000 142.3000 0.003581 188.86 0.0000 1.0000 0.0000 1.000 0.0000
LOBBY_FLR_1 VAV WITH REHEAT 0.000000 422.4350 0.001448 1308.19 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_1_FLR_3 FLR_3_DOAS 0.000000 6.0000 0.000396 156.09 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_2_FLR_3 FLR_3_DOAS 0.000000 6.0000 0.000396 156.07 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_3_MULT19_FLR_3 FLR_3_DOAS 0.000000 114.0000 0.000449 1863.81 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_4_MULT19_FLR_3 FLR_3_DOAS 0.000000 114.0000 0.000449 1864.32 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_5_FLR_3 FLR_3_DOAS 0.000000 6.0000 0.000396 156.09 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_6_FLR_3 FLR_3_DOAS 0.000000 6.0000 0.000396 156.07 0.0000 1.0000 0.0000 1.000 0.0000
CORRIDOR_FLR_3 VAV WITH REHEAT 0.000000 83.8280 0.000305 1557.62 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_1_FLR_6 FLR_3_DOAS 0.000000 1.5000 0.000396 39.02 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_2_FLR_6 FLR_3_DOAS 0.000000 1.5000 0.000396 39.02 0.0000 1.0000 0.0000 1.000 0.0000
ROOM_3_MULT9_FLR_6 FLR_3_DOAS 0.000000 13.5000 0.000449 220.77 0.0000 1.0000 0.0000 1.000 0.0000
BANQUET_FLR_6 VAV WITH REHEAT 0.000000 249.8960 0.003581 331.66 0.0000 1.0000 0.0000 1.000 0.0000
DINING_FLR_6 VAV WITH REHEAT 0.000000 249.8960 0.003581 331.66 0.0000 1.0000 0.0000 1.000 0.0000
KITCHEN_FLR_6 VAV WITH REHEAT 0.000000 22.2380 0.003556 103.30 0.0000 1.0000 0.0000 1.000 0.0000
CORRIDOR_FLR_6 VAV WITH REHEAT 0.000000 22.1800 0.000305 412.12 0.0000 1.0000 0.0000 1.000 0.0000


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
VAV WITH REHEAT   0.00 0.001045 6694.0231 0.0000 0.0000 0.0000
FLR_3_DOAS   0.00 0.000441 4651.2638 0.0000 0.0000 0.0000


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
BASEMENT VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.4646 2.4646 1.2052 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
RETAIL_1_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.5631 0.5631 0.2754 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
RETAIL_2_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.2492 0.2492 0.1219 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
MECH_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.2274 0.2274 0.1112 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
STORAGE_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.1101 0.1101 0.0538 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
LAUNDRY_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 3.3179 3.3179 1.6224 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CAFE_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.0911 2.0911 1.0226 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
LOBBY_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 5.4359 5.4359 2.6582 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_1_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_2_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_3_MULT19_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.8371 0.8371 0.8371 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_4_MULT19_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.8373 0.8373 0.8373 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_5_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_6_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORRIDOR_FLR_3 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.7410 1.7410 0.8513 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_1_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0154 0.0154 0.0154 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_2_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0154 0.0154 0.0154 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_3_MULT9_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0992 0.0992 0.0992 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
BANQUET_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.1471 2.1471 1.0500 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DINING_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.2484 2.2484 1.0995 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
KITCHEN_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.3702 2.3702 1.1590 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORRIDOR_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.8632 0.8632 0.4221 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
VAV WITH REHEAT 23.8294 23.6842 23.8294 11.6526 0.0000 1.0000
FLR_3_DOAS 2.0513 2.0513 2.0513 2.0513 0.0000 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
BASEMENT VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.2323 1.2323 1.2052 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
RETAIL_1_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.2816 0.2816 0.2754 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
RETAIL_2_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.1246 0.1246 0.1219 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
MECH_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.1137 0.1137 0.1112 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
STORAGE_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.0551 0.0551 0.0538 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
LAUNDRY_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.6589 1.6589 1.6224 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CAFE_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.0456 1.0456 1.0226 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
LOBBY_FLR_1 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.7180 2.7180 2.6582 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_1_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_2_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_3_MULT19_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.8371 0.8371 0.8371 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_4_MULT19_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.8373 0.8373 0.8373 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_5_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_6_FLR_3 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0617 0.0617 0.0617 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORRIDOR_FLR_3 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.8705 0.8705 0.8513 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_1_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0154 0.0154 0.0154 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_2_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0154 0.0154 0.0154 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
ROOM_3_MULT9_FLR_6 FLR_3_DOAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.0992 0.0992 0.0992 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
BANQUET_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.0736 1.0736 1.0500 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DINING_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.1242 1.1242 1.0995 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
KITCHEN_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.1851 1.1851 1.1590 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORRIDOR_FLR_6 VAV WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.4316 0.4316 0.4221 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
VAV WITH REHEAT 11.9147 11.6526 11.6526 11.6526 0.0000 1.0000
FLR_3_DOAS 2.0513 2.0513 2.0513 2.0513 0.0000 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Total gross floor area [m2] 11345.29
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
BASEMENT 1978.83 1978.83 0.00 168.00
RETAIL_1_FLR_1 67.07 67.07 0.00 168.00
RETAIL_2_FLR_1 77.67 77.67 0.00 168.00
MECH_FLR_1 164.24 164.24 0.00 168.00
STORAGE_FLR_1 94.76 94.76 0.00 168.00
LAUNDRY_FLR_1 78.04 78.04 0.00 168.00
CAFE_FLR_1 188.86 188.86 0.00 168.00
LOBBY_FLR_1 1308.19 1308.19 0.00 168.00
ROOM_1_FLR_3 39.02 39.02 0.00 168.00
ROOM_2_FLR_3 39.02 39.02 0.00 168.00
ROOM_3_MULT19_FLR_3 24.52 24.52 0.00 0.00
ROOM_4_MULT19_FLR_3 24.53 24.53 0.00 168.00
ROOM_5_FLR_3 39.02 39.02 0.00 168.00
ROOM_6_FLR_3 39.02 39.02 0.00 168.00
CORRIDOR_FLR_3 389.40 389.40 0.00 168.00
ROOM_1_FLR_6 39.02 39.02 0.00 168.00
ROOM_2_FLR_6 39.02 39.02 0.00 168.00
ROOM_3_MULT9_FLR_6 24.53 24.53 0.00 168.00
BANQUET_FLR_6 331.66 331.66 0.00 168.00
DINING_FLR_6 331.66 331.66 0.00 168.00
KITCHEN_FLR_6 103.30 103.30 0.00 168.00
CORRIDOR_FLR_6 412.12 412.12 0.00 168.00
Totals 11345.29 11345.29 0.00  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 51.17
Number of hours cooling loads not met 297.17
Number of hours not met 348.33


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heating -- Boiler 0.00 0.00 5420.38 1290744.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heating -- Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 326.86 122158.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsWired 766.57 62892.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 240.86 15448.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 959.56 59492.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- Cooking 762.04 29240.64 1198.64 74976.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- ReachInFreezer 14.43 457.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- ReachInRefrigerator 8.99 285.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- Laundry 0.00 0.00 590.20 39726.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Transformer 32.45 1868.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- ElevatorLift 616.11 37691.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- ElevatorLightsFan 2.91 188.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 553.69 45649.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 101.67 7970.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- General 245.76 9938.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 90.75 4739.94 3627.82 312653.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- General 7.09 2093.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- LowTempRefrigeration 20.30 2024.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- MedTempRefrigeration 33.60 1245.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1806.01 4783.66
Natural Gas 1788.84 10837.03
Additional 0.00 0.00
Total 3594.85 15620.69


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 67.57
Space Heating 0.00
Space Cooling 28.81
Fans (All) 48.80
Service Water Heating 8.00
Receptacle Equipment 153.81
Miscellaneous (All) 421.64
Subtotal 421.64


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 477.76
Service Water Heating 319.76
Miscellaneous (All) 955.20
Subtotal 955.20


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 4.91
Space Heating 34.70
Space Cooling 2.09
Fans (All) 3.54
Service Water Heating 23.81
Receptacle Equipment 22.62
Miscellaneous 8.33


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
LTG_SCH_KITCHEN 3061. 8760.
LTG_SCH_DINING 3061. 8760.
LTG_SCH_BASEMENT 2667. 8760.
LTG_SCH_LOBBY 3061. 8760.
LTG_SCH_STORAGE 1339. 8760.
LTG_SCH_MECHANIC 3061. 8760.
LTG_SCH_LAUNDRY 2678. 8760.
LTG_SCH_GUESTROOM 2482. 8760.
LTG_SCH_CORRIDOR 3061. 8760.
LTG_SCH_RETAIL 2678. 8760.
WALKIN_OCC_LGHT_SCH_2 1591. 8760.
EXTERIOR_LTG_SCH 4380. 4380.
BASEMENT_EQUIP_SCH 3924. 8760.
BLDG_EQUIP_SCH 3924. 8760.
GUESTROOM_EQP_SCH_BASE 3239. 8760.
GUESTROOM_EQP_SCH_ADVA 2762. 8760.
LOBBY_EQP_SCH 3292. 8760.
OFFICE_EQP_SCH 4941. 8760.
EMPLOYEELOUNGE_EQP_SCH 4044. 8760.
LAUNDRYROOM_EQP_ELEC_SCH 2920. 2920.
LAUNDRYROOM_EQP_GAS_SCH 2920. 2920.
MEETINGROOM_EQP_SCH 1336. 4745.
EXERCISEROOM_EQP_SCH 3832. 5840.
KITCHEN_ELEC_EQUIP_SCH 2172. 8760.
KITCHEN_GAS_EQUIP_SCH 1332. 8760.
KITCHEN_EXHAUST_SCH 6205. 6205.
BLDG_ELEVATORS 2270. 8760.
ELEV_LIGHT_FAN_SCH_24_7 8760. 8760.
ELEV_LIGHT_FAN_SCH_ADD_DF 2154. 8760.
BLDG_OCC_SCH 5026. 8760.
GUESTROOM_OCC_SCH 5515. 8760.
LOBBY_OCC_SCH 2304. 8760.
OFFICE_OCC_SCH 3954. 8760.
EMPLOYEELOUNGE_OCC_SCH 948. 5475.
MEETINGROOM_OCC_SCH 1168. 4745.
LAUNDRYROOM_OCC_SCH 427. 2920.
EXERCISEROOM_OCC_SCH 5292. 5840.
INFIL_SCH 8760. 8760.
INFIL_HALF_ON_SCH 4380. 8760.
INFIL_QUARTER_ON_SCH 2190. 8760.
LAUNDRY_SWH_SCH 2555. 2555.
BLDG_SWH_SCH 3301. 8760.
GUESTROOM_SWH_SCH 2899. 8760.
LAUNDRYROOM_SWH_SCH 2920. 2920.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
ALWAYS_ON 8760. 8760.
ALWAYS_OFF 0. 0.
FAN_SCH 8760. 8760.
REHEATCOILAVAILSCHED 8760. 8760.
COOLINGCOILAVAILSCHED 8760. 8760.
OCC_GUESTROOM_VENT_CTRL_30MIN 6570. 6570.
OCC_GUESTROOM_VENT_CTRL_20MIN 6327. 6327.
VAC_GUESTROOM_VENTILATION_SCHEDULE 365. 365.
MINOA_MOTORIZEDDAMPER_SCHED 8760. 8760.
MINOA_SCHED 8760. 8760.
WORK_EFF_SCH 0. 0.
ROOM_1_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_1_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_2_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_2_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_5_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_5_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_6_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_6_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_1_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_1_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_2_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_2_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
KITCHEN_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
KITCHEN_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
KITCHEN_FLR_6_CASE:1_WALKINFREEZER_CASECREDITREDUXSCHED 2774. 8760.
FLR_3_DOAS_OAMINOAFRACSCHEDULE 8760. 8760.
KITCHEN EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE 5740. 6205.
LAUNDRY_FLR_1 EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE 0. 0.
SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH 3285. 3285.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
VACGUESTROOM_HTGSP_SCH VACGUESTROOM THERMOSTAT DUAL SP CONTROL January 18.89 365 18.89 365
VACGUESTROOM_CLGSP_SCH VACGUESTROOM THERMOSTAT DUAL SP CONTROL July 23.33 365 23.33 365
OBCRESET_S_OCCGUESTROOM_HTGSP_SCH_30MIN S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL January 21.11 365 21.11 365
OBCRESET_S_OCCGUESTROOM_CLGSP_SCH_30MIN S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL July 23.33 365 21.11 365
OBCRESET_N_OCCGUESTROOM_HTGSP_SCH_30MIN N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL January 21.11 365 21.11 365
OBCRESET_N_OCCGUESTROOM_CLGSP_SCH_30MIN N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL July 23.33 365 21.11 365
HTGSETP_SCH BASEMENT DUAL SP CONTROL January 21.00 365 21.00 365
CLGSETP_SCH BASEMENT DUAL SP CONTROL July 24.00 365 24.00 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
BASEMENT 8760.00 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 8760.00 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 8760.00 0.00 0.00 0.00 0.00
MECH_FLR_1 8760.00 0.00 0.00 0.00 0.00
STORAGE_FLR_1 8760.00 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 8760.00 0.00 0.00 0.00 0.00
CAFE_FLR_1 8760.00 0.00 0.00 0.00 0.00
LOBBY_FLR_1 8760.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 8760.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 8760.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 8760.00 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 8760.00 0.00 0.00 0.00 0.00
BANQUET_FLR_6 8760.00 0.00 0.00 0.00 0.00
DINING_FLR_6 8760.00 0.00 0.00 0.00 0.00
KITCHEN_FLR_6 8759.83 0.17 0.00 0.00 0.00
CORRIDOR_FLR_6 8760.00 0.00 0.00 0.00 0.00
Min 8759.83 0.00 0.00 0.00 0.00
Max 8760.00 0.17 0.00 0.00 0.00
Average 8759.99 0.01 0.00 0.00 0.00
Sum 192719.83 0.17 0.00 0.00 0.00


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
BASEMENT 529331.00 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 50179.00 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 59156.00 0.00 0.00 0.00 0.00
MECH_FLR_1 8977.00 0.00 0.00 0.00 0.00
STORAGE_FLR_1 5588.00 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 37203.00 0.00 0.00 0.00 0.00
CAFE_FLR_1 710417.00 0.00 0.00 0.00 0.00
LOBBY_FLR_1 2115429.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 4154.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 100358.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 4154.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 4154.00 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 4154.00 0.00 0.00 0.00 0.00
BANQUET_FLR_6 1245715.00 0.00 0.00 0.00 0.00
DINING_FLR_6 1245715.00 0.00 0.00 0.00 0.00
KITCHEN_FLR_6 108268.33 0.67 0.00 0.00 0.00
CORRIDOR_FLR_6 105946.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 2115429.00 0.67 0.00 0.00 0.00
Average 288887.02 0.03 0.00 0.00 0.00
Sum 6355514.33 0.67 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
BASEMENT 8760.00 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 8760.00 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 8760.00 0.00 0.00 0.00 0.00
MECH_FLR_1 8760.00 0.00 0.00 0.00 0.00
STORAGE_FLR_1 8760.00 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 8760.00 0.00 0.00 0.00 0.00
CAFE_FLR_1 8760.00 0.00 0.00 0.00 0.00
LOBBY_FLR_1 8745.00 15.00 0.00 0.00 0.00
ROOM_1_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 8760.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 8760.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 8760.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 8760.00 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 8760.00 0.00 0.00 0.00 0.00
BANQUET_FLR_6 8744.83 15.17 0.00 0.00 0.00
DINING_FLR_6 8750.83 9.17 0.00 0.00 0.00
KITCHEN_FLR_6 8759.33 0.67 0.00 0.00 0.00
CORRIDOR_FLR_6 8760.00 0.00 0.00 0.00 0.00
Min 8744.83 0.00 0.00 0.00 0.00
Max 8760.00 15.17 0.00 0.00 0.00
Average 8758.18 1.82 0.00 0.00 0.00
Sum 192680.00 40.00 0.00 0.00 0.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
BASEMENT 529331.00 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 50179.00 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 59156.00 0.00 0.00 0.00 0.00
MECH_FLR_1 8977.00 0.00 0.00 0.00 0.00
STORAGE_FLR_1 5588.00 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 37203.00 0.00 0.00 0.00 0.00
CAFE_FLR_1 710417.00 0.00 0.00 0.00 0.00
LOBBY_FLR_1 2110012.33 5416.67 0.00 0.00 0.00
ROOM_1_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 4154.00 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 4154.00 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 100358.00 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 4154.00 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 4154.00 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 4154.00 0.00 0.00 0.00 0.00
BANQUET_FLR_6 1242609.33 3105.67 0.00 0.00 0.00
DINING_FLR_6 1243878.33 1836.67 0.00 0.00 0.00
KITCHEN_FLR_6 108261.67 7.33 0.00 0.00 0.00
CORRIDOR_FLR_6 105946.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 2110012.33 5416.67 0.00 0.00 0.00
Average 288415.85 471.20 0.00 0.00 0.00
Sum 6345148.67 10366.33 0.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:59:07

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
BASEMENT 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 0.00 0.00 0.00 0.00
MECH_FLR_1 0.00 0.00 0.00 0.00
STORAGE_FLR_1 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 0.00 0.00 0.00 0.00
CAFE_FLR_1 0.00 8760.00 0.00 0.00
LOBBY_FLR_1 0.00 8760.00 0.00 0.00
ROOM_1_FLR_3 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 0.00 0.00 0.00 0.00
BANQUET_FLR_6 0.00 8760.00 0.00 0.00
DINING_FLR_6 0.00 8760.00 0.00 0.00
KITCHEN_FLR_6 0.00 0.00 0.00 0.00
CORRIDOR_FLR_6 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 8760.00 0.00 0.00
Average 0.00 1592.73 0.00 0.00
Sum 0.00 35040.00 0.00 0.00


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
BASEMENT 0.00 0.00 0.00 0.00
RETAIL_1_FLR_1 0.00 0.00 0.00 0.00
RETAIL_2_FLR_1 0.00 0.00 0.00 0.00
MECH_FLR_1 0.00 0.00 0.00 0.00
STORAGE_FLR_1 0.00 0.00 0.00 0.00
LAUNDRY_FLR_1 0.00 0.00 0.00 0.00
CAFE_FLR_1 0.00 710417.00 0.00 0.00
LOBBY_FLR_1 0.00 2115429.00 0.00 0.00
ROOM_1_FLR_3 0.00 0.00 0.00 0.00
ROOM_2_FLR_3 0.00 0.00 0.00 0.00
ROOM_3_MULT19_FLR_3 0.00 0.00 0.00 0.00
ROOM_4_MULT19_FLR_3 0.00 0.00 0.00 0.00
ROOM_5_FLR_3 0.00 0.00 0.00 0.00
ROOM_6_FLR_3 0.00 0.00 0.00 0.00
CORRIDOR_FLR_3 0.00 0.00 0.00 0.00
ROOM_1_FLR_6 0.00 0.00 0.00 0.00
ROOM_2_FLR_6 0.00 0.00 0.00 0.00
ROOM_3_MULT9_FLR_6 0.00 0.00 0.00 0.00
BANQUET_FLR_6 0.00 1245715.00 0.00 0.00
DINING_FLR_6 0.00 1245715.00 0.00 0.00
KITCHEN_FLR_6 0.00 0.00 0.00 0.00
CORRIDOR_FLR_6 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 2115429.00 0.00 0.00
Average 0.00 241694.36 0.00 0.00
Sum 0.00 5317276.00 0.00 0.00



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 8

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AK_FAIRBANKS

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January -17.62
February -15.41
March -10.29
April 0.726
May 10.596
June 15.955
July 16.857
August 14.239
September 6.723
October -3.07
November -17.64
December -19.26
   
Annual Sum or Average -1.44
Minimum of Months -19.26
Maximum of Months 16.857



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.291671E+11 22434.19 11-JAN-21:00 -35.6 -35.7 0.722015E+10 4703.64 25-JAN-22:10 -23.3 -23.5
February 0.228865E+11 15754.04 28-FEB-22:05 -29.6 -29.7 0.605217E+10 4501.13 01-FEB-22:10 -29.6 -29.7
March 0.242247E+11 13996.99 22-MAR-18:58 3.90 0.76 0.668029E+10 4252.54 30-MAR-21:10 -16.5 -17.7
April 0.247008E+11 19469.90 23-APR-08:62 6.97 1.91 0.671689E+10 4449.78 18-APR-21:10 6.97 1.91
May 0.268770E+11 21081.44 18-MAY-00:52 5.60 3.00 0.711240E+10 4534.63 26-MAY-21:10 3.12 1.18
June 0.279572E+11 16698.56 03-JUN-03:00 8.90 7.24 0.705775E+10 4541.42 15-JUN-21:19 16.33 10.71
July 0.319870E+11 21356.48 31-JUL-04:23 7.20 6.52 0.780138E+10 4837.03 28-JUL-22:10 7.20 6.52
August 0.357963E+11 37113.71 29-AUG-22:01 4.22 1.11 0.816976E+10 4906.83 21-AUG-00:20 4.22 1.11
September 0.362576E+11 41206.40 06-SEP-23:52 6.10 5.06 0.794832E+10 5024.41 06-SEP-23:00 6.10 5.06
October 0.367856E+11 36078.89 07-OCT-20:31 4.07 3.24 0.820421E+10 4947.90 04-OCT-00:10 4.07 3.24
November 0.343531E+11 20124.89 01-NOV-21:00 -8.9 -9.5 0.779097E+10 4837.09 08-NOV-00:20 -23.0 -23.2
December 0.319013E+11 20866.41 15-DEC-08:00 -33.9 -34.0 0.765872E+10 4836.95 04-DEC-22:10 -33.9 -34.0
                     
Annual Sum or Average 0.362894E+12         0.884130E+11        
Minimum of Months 0.228865E+11 13996.99   -35.6 -35.7 0.605217E+10 4252.54   -33.9 -34.0
Maximum of Months 0.367856E+11 41206.40   8.90 7.24 0.820421E+10 5024.41   16.33 10.71



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 11219209.78 769.81 30-JAN-12:30 -23.9 -24.3 0.615592E+09 364.24 26-JAN-00:00 -23.9 -24.3
February 0.286496E+09 2184.94 15-FEB-13:40 -8.7 -9.6 0.560236E+09 364.23 25-FEB-01:39 -26.1 -26.4
March 0.142226E+10 3643.06 22-MAR-14:51 5.60 2.22 0.630153E+09 364.44 16-MAR-03:09 5.60 2.22
April 0.384732E+10 7772.62 13-APR-15:07 5.10 0.93 0.631596E+09 419.80 20-APR-21:19 6.33 2.30
May 0.523226E+10 4760.81 12-MAY-13:30 20.60 9.86 0.659725E+09 430.20 31-MAY-21:30 16.00 9.64
June 0.580368E+10 4309.22 29-JUN-14:10 25.68 16.21 0.658307E+09 445.58 21-JUN-21:10 25.68 16.21
July 0.602528E+10 5057.87 23-JUL-13:30 25.00 15.26 0.675024E+09 446.77 21-JUL-21:19 25.00 15.26
August 0.563508E+10 5870.69 30-AUG-13:08 8.98 2.62 0.667792E+09 448.79 11-AUG-21:30 8.98 2.62
September 0.336855E+10 5432.31 28-SEP-14:03 5.68 1.75 0.616559E+09 399.96 06-SEP-23:00 5.68 1.75
October 0.117864E+10 4761.01 03-OCT-12:45 9.63 5.75 0.623054E+09 391.00 04-OCT-00:10 7.62 3.01
November 45696331.36 1812.57 08-NOV-13:20 -13.7 -14.5 0.599286E+09 364.39 16-NOV-23:19 -23.9 -24.1
December 0.00 0.00 01-DEC-00:02 -25.8 -26.0 0.619388E+09 364.37 19-DEC-00:00 -23.9 -24.1
                     
Annual Sum or Average 0.328565E+11         0.755671E+10        
Minimum of Months 0.00 0.00   -25.8 -26.0 0.560236E+09 364.23   -26.1 -26.4
Maximum of Months 0.602528E+10 7772.62   25.68 16.21 0.675024E+09 448.79   25.68 16.21



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.106487E+10 975.52 30-JAN-22:10 -25.8 -26.1 0.722185E+09 458.40 23-JAN-22:10 -25.8 -26.1
February 0.131409E+10 1174.46 21-FEB-23:03 -26.2 -26.4 0.659973E+09 483.50 09-FEB-22:10 -26.2 -26.4
March 0.202089E+10 1468.50 22-MAR-18:58 3.90 0.76 0.758650E+09 517.40 22-MAR-21:40 1.87 0.05
April 0.262526E+10 2693.18 20-APR-21:29 6.15 2.20 0.824677E+09 570.08 27-APR-22:19 4.83 1.92
May 0.304635E+10 2247.18 18-MAY-00:52 5.60 3.00 0.907291E+09 576.57 01-MAY-22:10 5.60 3.00
June 0.323797E+10 2002.78 21-JUN-21:00 23.90 13.75 0.902915E+09 569.57 30-JUN-23:49 15.32 13.53
July 0.335747E+10 2160.03 31-JUL-04:23 7.20 6.52 0.928052E+09 569.57 21-JUL-23:10 7.20 6.52
August 0.322049E+10 2495.96 28-AUG-06:00 5.60 4.81 0.923149E+09 571.18 29-AUG-21:40 4.97 1.82
September 0.264901E+10 2255.54 03-SEP-01:23 7.20 5.89 0.840248E+09 570.08 08-SEP-22:30 6.95 5.53
October 0.222689E+10 1897.84 03-OCT-23:20 7.80 3.23 0.782271E+09 558.62 03-OCT-21:00 7.80 3.23
November 0.119485E+10 1056.30 08-NOV-23:05 -24.6 -24.9 0.700534E+09 465.59 01-NOV-21:10 -24.6 -24.9
December 0.894449E+09 1028.56 27-DEC-22:20 -26.1 -26.3 0.719685E+09 447.78 19-DEC-22:10 -26.1 -26.3
                     
Annual Sum or Average 0.268526E+11         0.966963E+10        
Minimum of Months 0.894449E+09 975.52   -26.2 -26.4 0.659973E+09 447.78   -26.2 -26.4
Maximum of Months 0.335747E+10 2693.18   23.90 13.75 0.928052E+09 576.57   15.32 13.53



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 45945421.67 535.81 22-JAN-21:00 -6.1 -6.3 0.151697E+09 89.15 26-JAN-00:00 -23.9 -24.2
February 0.128968E+09 823.60 09-FEB-21:00 -8.9 -9.2 0.137170E+09 90.66 09-FEB-22:10 -9.6 -9.9
March 0.446340E+09 1175.31 22-MAR-18:58 3.90 0.76 0.152728E+09 96.08 22-MAR-21:10 2.12 0.08
April 0.167974E+10 1773.19 23-APR-08:62 6.97 1.91 0.154907E+09 107.25 21-APR-21:10 6.97 1.91
May 0.254082E+10 1950.26 18-MAY-00:52 5.60 3.00 0.179464E+09 116.47 31-MAY-21:19 16.23 9.72
June 0.282264E+10 1674.63 22-JUN-20:00 21.70 12.19 0.186567E+09 120.46 16-JUN-21:10 21.70 12.19
July 0.297896E+10 1924.63 31-JUL-04:23 7.20 6.52 0.193709E+09 120.46 10-JUL-22:10 7.20 6.52
August 0.278731E+10 1957.55 28-AUG-04:42 6.38 5.53 0.189214E+09 120.46 03-AUG-22:10 6.38 5.53
September 0.215176E+10 1969.23 03-SEP-01:23 7.20 5.89 0.164440E+09 110.77 01-SEP-21:10 7.20 5.89
October 0.111263E+10 1577.00 03-OCT-23:20 7.80 3.23 0.154850E+09 102.95 04-OCT-21:10 3.30 1.41
November 56896028.08 637.31 02-NOV-21:00 -9.4 -9.6 0.146741E+09 89.15 08-NOV-01:39 -23.7 -24.0
December 22783395.13 557.39 24-DEC-21:00 -7.2 -7.4 0.151696E+09 89.15 19-DEC-01:00 -7.2 -7.4
                     
Annual Sum or Average 0.167748E+11         0.196318E+10        
Minimum of Months 22783395.13 535.81   -9.4 -9.6 0.137170E+09 89.15   -23.9 -24.2
Maximum of Months 0.297896E+10 1969.23   21.70 12.19 0.193709E+09 120.46   21.70 12.19



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9 -15.4 0.116664E+09 68.58 26-JAN-01:49 -23.9 -24.2
February 1955814.36 116.72 08-FEB-22:00 1.10 -1.7 0.105502E+09 68.58 18-FEB-05:19 -23.5 -23.8
March 46708471.08 554.51 22-MAR-15:03 5.60 2.29 0.117248E+09 69.60 22-MAR-22:10 1.42 -0.3
April 0.668041E+09 836.34 23-APR-08:62 6.97 1.91 0.116675E+09 78.28 21-APR-21:40 6.97 1.91
May 0.118449E+10 927.10 18-MAY-00:52 5.60 3.00 0.134039E+09 85.35 31-MAY-21:40 15.77 9.56
June 0.132056E+10 756.92 03-JUN-03:00 8.90 7.24 0.140215E+09 91.35 22-JUN-21:19 20.20 11.92
July 0.138920E+10 923.04 31-JUL-04:23 7.20 6.52 0.145674E+09 91.85 11-JUL-21:10 7.20 6.52
August 0.130142E+10 937.43 28-AUG-04:42 6.38 5.53 0.141560E+09 89.77 02-AUG-21:40 6.38 5.53
September 0.943933E+09 934.02 03-SEP-01:23 7.20 5.89 0.122380E+09 80.47 01-SEP-21:00 7.20 5.89
October 0.319458E+09 744.89 03-OCT-23:20 7.80 3.23 0.117628E+09 74.44 03-OCT-21:00 7.80 3.23
November 0.00 0.00 01-NOV-00:05 -10.0 -10.9 0.112879E+09 68.58 08-NOV-03:39 -24.1 -24.4
December 0.00 0.00 01-DEC-00:02 -25.8 -26.0 0.116691E+09 68.58 19-DEC-01:49 -24.3 -24.5
                     
Annual Sum or Average 0.717576E+10         0.148715E+10        
Minimum of Months 0.00 0.00   -25.8 -26.0 0.105502E+09 68.58   -24.3 -24.5
Maximum of Months 0.138920E+10 937.43   8.90 7.24 0.145674E+09 91.85   20.20 11.92



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.445231E+11 35341.89 19-JAN-21:00 -10.0 -10.4 0.564200E+09 381.60 03-JAN-22:19 -10.0 -10.4
February 0.408896E+11 36029.13 09-FEB-21:00 -8.9 -9.2 0.514645E+09 381.59 02-FEB-22:10 -8.9 -9.2
March 0.467922E+11 47263.13 22-MAR-18:58 3.90 0.76 0.585239E+09 381.65 22-MAR-21:10 2.12 0.08
April 0.474904E+11 51663.07 13-APR-20:27 2.80 -1.2 0.581287E+09 487.87 18-APR-21:19 4.03 -0.4
May 0.513834E+11 50538.97 26-MAY-20:40 3.50 1.53 0.610395E+09 534.98 01-MAY-22:10 3.50 1.53
June 0.508297E+11 38811.26 29-JUN-20:00 25.00 16.66 0.588279E+09 392.17 01-JUN-04:30 25.00 16.66
July 0.524434E+11 38895.18 21-JUL-20:00 25.00 16.11 0.606520E+09 397.28 05-JUL-04:00 25.00 16.11
August 0.519852E+11 50837.29 30-AUG-20:57 5.60 1.46 0.608004E+09 468.29 29-AUG-21:40 5.60 1.46
September 0.482193E+11 50614.15 21-SEP-18:49 5.68 4.11 0.589394E+09 481.73 10-SEP-23:10 5.68 4.11
October 0.475656E+11 49304.94 02-OCT-20:00 5.00 4.22 0.594690E+09 469.57 05-OCT-21:40 7.60 4.05
November 0.433333E+11 35484.19 01-NOV-20:00 -8.9 -9.5 0.552586E+09 381.63 20-NOV-22:10 -8.9 -9.4
December 0.439650E+11 34971.25 19-DEC-21:00 -6.1 -7.0 0.566397E+09 381.60 20-DEC-22:10 -17.5 -17.8
                     
Annual Sum or Average 0.569420E+12         0.696164E+10        
Minimum of Months 0.408896E+11 34971.25   -10.0 -10.4 0.514645E+09 381.59   -17.5 -17.8
Maximum of Months 0.524434E+11 51663.07   25.00 16.66 0.610395E+09 534.98   25.00 16.66



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.537493E+10 6652.50 06-JAN-23:00 -2.8 -3.9 0.812640E+10 4789.05 13-JAN-01:39 -33.9 -34.0
February 0.840440E+10 8608.33 15-FEB-13:40 -8.7 -9.6 0.738448E+10 5049.44 08-FEB-22:40 -8.7 -9.6
March 0.158625E+11 16755.71 22-MAR-14:35 5.60 2.12 0.851867E+10 5696.51 22-MAR-21:40 1.87 0.05
April 0.219270E+11 29194.22 13-APR-15:07 5.10 0.93 0.911578E+10 6508.80 19-APR-23:30 4.70 1.59
May 0.248476E+11 20730.31 11-MAY-01:30 7.75 2.66 0.987977E+10 6598.31 29-MAY-23:40 6.13 4.29
June 0.254598E+11 15475.17 20-JUN-15:03 25.10 14.57 0.984428E+10 6480.77 01-JUN-02:00 25.10 14.57
July 0.264466E+11 17224.46 31-JUL-04:33 7.20 6.46 0.100788E+11 6461.67 21-JUL-22:49 7.20 6.46
August 0.257385E+11 22706.12 30-AUG-15:03 9.40 3.01 0.998616E+10 6552.51 29-AUG-01:49 9.40 3.01
September 0.202933E+11 22928.21 28-SEP-15:10 6.20 2.04 0.903350E+10 6543.97 06-SEP-23:00 6.20 2.04
October 0.149674E+11 20337.75 04-OCT-03:23 7.50 2.69 0.851087E+10 6361.88 03-OCT-21:00 7.50 2.69
November 0.600434E+10 7330.39 08-NOV-13:30 -13.6 -14.4 0.787845E+10 4871.32 01-NOV-21:40 -13.6 -14.4
December 0.424339E+10 6029.69 19-DEC-22:10 -8.3 -8.9 0.814167E+10 4788.79 04-DEC-22:00 -8.3 -8.9
                     
Annual Sum or Average 0.199570E+12         0.106499E+12        
Minimum of Months 0.424339E+10 6029.69   -13.6 -14.4 0.738448E+10 4788.79   -33.9 -34.0
Maximum of Months 0.264466E+11 29194.22   25.10 14.57 0.100788E+11 6598.31   25.10 14.57



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.340473E+11 23425.27 30-JAN-23:05 -24.4 -24.8 0.249628E+11 16368.66 06-JAN-23:10 -24.4 -24.8
February 0.382034E+11 27352.84 21-FEB-23:03 -26.2 -26.4 0.229927E+11 17183.38 09-FEB-22:49 -26.2 -26.4
March 0.522927E+11 33783.96 22-MAR-15:10 5.60 2.29 0.269622E+11 18506.72 22-MAR-21:49 1.78 0.04
April 0.616250E+11 67039.82 20-APR-21:29 6.15 2.20 0.290749E+11 19566.49 18-APR-21:19 6.15 2.20
May 0.709948E+11 66581.01 15-MAY-23:15 6.50 2.19 0.315950E+11 20138.19 29-MAY-23:40 6.13 4.29
June 0.744508E+11 60506.21 01-JUN-04:37 7.03 5.10 0.310853E+11 19769.47 01-JUN-02:00 7.03 5.10
July 0.773172E+11 56989.70 31-JUL-03:55 7.20 6.67 0.319932E+11 19510.16 05-JUL-04:00 7.20 6.67
August 0.745506E+11 63357.44 29-AUG-21:14 5.53 2.44 0.319691E+11 19890.70 28-AUG-04:10 5.53 2.44
September 0.618091E+11 66862.66 18-SEP-21:50 6.38 4.32 0.295992E+11 20034.23 06-SEP-23:00 6.38 4.32
October 0.538893E+11 59422.03 04-OCT-01:53 7.20 2.62 0.277692E+11 19381.03 03-OCT-21:00 7.20 2.62
November 0.360643E+11 25431.38 09-NOV-00:03 -25.7 -25.9 0.242779E+11 16677.93 01-NOV-22:10 -25.7 -25.9
December 0.309615E+11 26760.00 27-DEC-23:03 -26.3 -26.5 0.246320E+11 16043.45 19-DEC-23:10 -26.3 -26.5
                     
Annual Sum or Average 0.666206E+12         0.336913E+12        
Minimum of Months 0.309615E+11 23425.27   -26.3 -26.5 0.229927E+11 16043.45   -26.3 -26.5
Maximum of Months 0.773172E+11 67039.82   7.20 6.67 0.319932E+11 20138.19   7.20 6.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 5522100.31 541.08 12-JAN-08:61 -38.2 -38.3 92280104.41 56.69 03-JAN-04:19 -38.2 -38.3
February 13384238.22 702.31 11-FEB-19:04 -3.0 -3.9 83402168.65 56.69 21-FEB-04:19 -22.8 -23.0
March 87417027.33 3139.06 29-MAR-15:01 -6.6 -9.6 93521672.93 56.69 17-MAR-03:20 -6.6 -9.6
April 0.788883E+09 3474.85 13-APR-15:01 5.10 0.93 93685590.85 56.69 21-APR-21:00 7.20 2.28
May 0.144873E+10 3684.76 31-MAY-15:02 21.28 10.75 98368560.06 56.69 10-MAY-21:10 21.28 10.75
June 0.214187E+10 3751.30 19-JUN-18:02 22.88 12.85 95614087.96 56.70 29-JUN-22:40 20.53 15.75
July 0.207733E+10 3544.83 29-JUL-18:02 27.12 18.22 98677173.23 56.70 24-JUL-21:10 27.12 18.22
August 0.157366E+10 3752.02 10-AUG-18:02 22.62 12.07 98421742.33 56.70 01-AUG-21:40 22.62 12.07
September 0.426854E+09 3400.02 09-SEP-15:02 15.10 8.93 93067942.26 56.69 01-SEP-01:10 15.10 8.93
October 53446118.56 3327.45 03-OCT-15:01 12.62 6.83 93161693.13 56.69 02-OCT-04:30 12.62 6.83
November 5196838.27 404.96 29-NOV-08:61 -29.0 -29.2 89354338.68 56.69 17-NOV-04:19 -29.0 -29.2
December 4862181.07 602.62 24-DEC-09:04 0.18 -1.3 92203376.01 56.69 17-DEC-02:20 0.18 -1.3
                     
Annual Sum or Average 0.862716E+10         0.112176E+10        
Minimum of Months 4862181.07 404.96   -38.2 -38.3 83402168.65 56.69   -38.2 -38.3
Maximum of Months 0.214187E+10 3752.02   27.12 18.22 98677173.23 56.70   27.12 18.22



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 5281693.96 553.14 22-JAN-09:04 -6.2 -6.5 92278460.51 56.69 24-JAN-04:19 -18.5 -18.8
February 6619380.38 793.84 09-FEB-16:04 0.13 -0.8 83356196.18 56.69 05-FEB-02:20 0.13 -0.8
March 22160695.28 1183.57 20-MAR-15:03 6.52 2.22 92679172.63 56.69 14-MAR-03:20 6.52 2.22
April 0.427614E+09 3094.06 21-APR-18:02 14.22 5.92 92125805.17 56.69 28-APR-21:10 3.53 1.78
May 0.107853E+10 3282.23 31-MAY-15:02 21.28 10.75 97799743.78 56.69 30-MAY-21:10 21.28 10.75
June 0.189617E+10 3399.38 19-JUN-18:02 22.88 12.85 95524305.28 56.70 29-JUN-21:10 23.22 16.42
July 0.178969E+10 3253.37 29-JUL-18:02 27.12 18.22 98544831.53 56.70 24-JUL-21:10 27.12 18.22
August 0.117556E+10 3376.74 10-AUG-18:02 22.62 12.07 97909954.85 56.70 02-AUG-21:10 22.62 12.07
September 0.227374E+09 3045.92 02-SEP-18:02 16.52 10.34 91905455.25 56.69 01-SEP-01:19 16.52 10.34
October 29071639.44 1424.83 04-OCT-18:03 7.43 3.81 92641417.17 56.69 02-OCT-04:30 7.43 3.81
November 4591379.41 404.73 29-NOV-08:61 -29.0 -29.2 89353064.36 56.69 07-NOV-04:19 -29.0 -29.2
December 4831776.87 671.41 24-DEC-09:04 0.18 -1.3 92202734.71 56.69 21-DEC-00:20 0.18 -1.3
                     
Annual Sum or Average 0.666749E+10         0.111632E+10        
Minimum of Months 4591379.41 404.73   -29.0 -29.2 83356196.18 56.69   -29.0 -29.2
Maximum of Months 0.189617E+10 3399.38   27.12 18.22 98544831.53 56.70   27.12 18.22



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 1690292.49 137.79 30-JAN-12:30 -23.9 -24.3 0.00 0.00 01-JAN-00:10 -23.9 -24.3
February 27138523.30 194.63 26-FEB-13:30 -24.4 -24.8 0.00 0.00 01-FEB-00:10 -24.4 -24.8
March 0.137977E+09 372.51 29-MAR-14:30 -6.7 -9.6 0.00 0.00 01-MAR-00:10 -6.7 -9.6
April 0.510595E+09 904.78 22-APR-13:20 15.20 6.93 0.00 0.00 01-APR-00:10 15.20 6.93
May 0.654686E+09 885.12 12-MAY-13:20 20.60 9.86 0.00 0.00 01-MAY-00:10 20.60 9.86
June 0.730048E+09 803.30 30-JUN-12:30 26.15 17.75 0.00 0.00 01-JUN-00:10 26.15 17.75
July 0.778783E+09 945.13 23-JUL-13:30 25.00 15.26 0.00 0.00 01-JUL-00:10 25.00 15.26
August 0.716477E+09 987.54 25-AUG-13:30 21.70 14.78 0.00 0.00 01-AUG-00:10 21.70 14.78
September 0.387758E+09 832.15 09-SEP-13:10 12.98 8.62 0.00 0.00 01-SEP-00:10 12.98 8.62
October 0.123093E+09 475.21 03-OCT-12:55 10.00 5.88 0.00 0.00 01-OCT-00:10 10.00 5.88
November 4660116.11 75.54 08-NOV-14:30 -13.6 -14.3 0.00 0.00 01-NOV-00:10 -13.6 -14.3
December 0.00 0.00 01-DEC-00:02 -25.8 -26.0 0.00 0.00 01-DEC-00:10 -25.8 -26.0
                     
Annual Sum or Average 0.407291E+10         0.00        
Minimum of Months 0.00 0.00   -25.8 -26.0 0.00 0.00   -25.8 -26.0
Maximum of Months 0.778783E+09 987.54   26.15 17.75 0.00 0.00   26.15 17.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 18732939.21 390.72 12-JAN-08:61 -38.2 -38.3 92600913.54 56.69 27-JAN-04:19 -14.8 -15.1
February 22568495.38 587.54 10-FEB-19:04 -3.1 -4.0 83763670.52 56.69 07-FEB-04:19 -3.1 -4.0
March 40824776.86 558.34 10-MAR-19:04 -7.4 -8.3 93427213.69 56.69 14-MAR-03:20 -18.9 -19.7
April 0.152016E+09 828.20 30-APR-18:01 9.72 3.97 91884970.10 56.69 27-APR-21:49 9.72 3.97
May 0.504178E+09 945.34 31-MAY-18:02 21.13 10.92 96875389.01 56.69 11-MAY-21:30 21.13 10.92
June 0.763796E+09 1002.17 22-JUN-18:02 23.22 12.45 94538395.48 56.69 29-JUN-21:00 22.80 16.33
July 0.770181E+09 1006.14 13-JUL-18:02 23.90 13.18 97550031.14 56.69 11-JUL-04:49 23.90 13.18
August 0.547599E+09 954.59 10-AUG-18:02 22.62 12.07 96981301.55 56.69 03-AUG-22:40 22.62 12.07
September 0.214284E+09 807.12 02-SEP-15:02 16.70 10.75 92393044.25 56.69 01-SEP-01:19 16.70 10.75
October 63626437.96 587.80 24-OCT-18:04 -2.9 -3.3 93817133.73 56.69 05-OCT-21:30 -2.9 -3.3
November 17322972.02 469.41 05-NOV-08:04 -14.3 -14.8 89665974.07 56.69 17-NOV-04:19 -20.6 -20.8
December 16843978.40 503.76 24-DEC-19:04 -4.0 -4.2 92489443.95 56.69 18-DEC-00:20 -4.0 -4.2
                     
Annual Sum or Average 0.313197E+10         0.111599E+10        
Minimum of Months 16843978.40 390.72   -38.2 -38.3 83763670.52 56.69   -20.6 -20.8
Maximum of Months 0.770181E+09 1006.14   23.90 13.18 97550031.14 56.69   23.90 16.33



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 5931840.95 541.10 12-JAN-08:61 -38.2 -38.3 92280653.26 56.69 06-JAN-04:19 -38.2 -38.3
February 18205205.67 753.32 10-FEB-19:04 -3.1 -4.0 83487051.65 56.69 21-FEB-04:19 -22.8 -23.0
March 0.128852E+09 3037.57 22-MAR-15:02 5.60 2.29 94481893.86 56.69 10-MAR-04:19 5.60 2.29
April 0.745773E+09 3256.30 13-APR-15:01 5.10 0.93 94216538.18 56.69 28-APR-21:10 3.53 1.78
May 0.197825E+10 3456.33 31-MAY-15:02 21.28 10.75 98849015.13 56.69 12-MAY-04:49 21.28 10.75
June 0.243278E+10 3494.02 22-JUN-15:02 22.88 11.98 95844309.32 56.70 30-JUN-21:19 18.47 14.95
July 0.252691E+10 3425.47 29-JUL-18:02 27.12 18.22 98933152.40 56.70 21-JUL-22:40 27.12 18.22
August 0.188029E+10 3509.11 10-AUG-15:02 22.30 12.06 98815340.31 56.70 25-AUG-21:40 16.30 12.97
September 0.561749E+09 3185.40 09-SEP-15:02 15.10 8.93 93747074.12 56.69 01-SEP-01:10 15.10 8.93
October 84299405.89 3138.66 03-OCT-15:01 12.62 6.83 93611523.89 56.69 02-OCT-00:49 12.62 6.83
November 5616304.05 404.98 29-NOV-08:61 -29.0 -29.2 89355012.50 56.69 14-NOV-04:19 -29.0 -29.2
December 4937912.42 642.11 24-DEC-09:04 0.18 -1.3 92203070.98 56.69 30-DEC-00:20 -15.6 -15.9
                     
Annual Sum or Average 0.103736E+11         0.112582E+10        
Minimum of Months 4937912.42 404.98   -38.2 -38.3 83487051.65 56.69   -38.2 -38.3
Maximum of Months 0.252691E+10 3509.11   27.12 18.22 98933152.40 56.70   27.12 18.22



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 5559249.67 540.98 12-JAN-08:61 -38.2 -38.3 92278559.91 56.69 24-JAN-04:19 -18.5 -18.8
February 8838837.75 817.34 09-FEB-19:04 -7.5 -7.8 83366493.79 56.69 14-FEB-04:19 -15.7 -16.0
March 56407572.41 1309.13 10-MAR-09:03 -8.1 -8.7 93162250.02 56.69 14-MAR-03:20 -18.9 -19.7
April 0.362585E+09 2915.12 22-APR-08:62 5.55 1.86 92846532.97 56.69 28-APR-21:10 3.53 1.78
May 0.156035E+10 3095.02 31-MAY-15:02 21.28 10.75 98646190.04 56.69 31-MAY-04:40 21.28 10.75
June 0.216563E+10 3161.36 22-JUN-15:02 22.88 11.98 95808900.12 56.70 30-JUN-21:30 18.25 14.71
July 0.221836E+10 3169.45 13-JUL-18:02 23.90 13.18 98895502.38 56.70 24-JUL-21:10 19.32 15.49
August 0.144389E+10 3125.12 10-AUG-15:02 22.30 12.06 98585657.55 56.69 02-AUG-21:10 22.30 12.06
September 0.318132E+09 2877.67 10-SEP-08:62 8.77 4.89 92884205.32 56.69 01-SEP-01:19 8.77 4.89
October 45096479.57 2546.16 04-OCT-08:61 7.88 2.97 92971826.56 56.69 04-OCT-04:10 7.88 2.97
November 4820844.46 415.80 04-NOV-08:04 -8.3 -9.8 89353207.00 56.69 14-NOV-04:19 -15.0 -15.4
December 4912009.65 708.85 24-DEC-09:04 0.18 -1.3 92202982.69 56.69 01-DEC-04:19 0.18 -1.3
                     
Annual Sum or Average 0.819459E+10         0.112100E+10        
Minimum of Months 4820844.46 415.80   -38.2 -38.3 83366493.79 56.69   -18.9 -19.7
Maximum of Months 0.221836E+10 3169.45   23.90 13.18 98895502.38 56.70   22.30 15.49



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 61705571.09 526.56 06-JAN-23:00 -2.8 -3.9 0.119869E+10 704.48 26-JAN-03:09 -24.4 -24.6
February 0.306654E+09 1121.87 09-FEB-22:10 -9.6 -9.9 0.108387E+10 704.51 18-FEB-05:19 -23.5 -23.8
March 0.157486E+10 2309.50 22-MAR-15:41 5.60 2.55 0.120657E+10 737.20 22-MAR-21:40 1.87 0.05
April 0.376104E+10 3469.97 23-APR-08:62 6.97 1.91 0.125635E+10 858.74 21-APR-21:30 6.97 1.91
May 0.508615E+10 3831.44 18-MAY-00:52 5.60 3.00 0.145690E+10 920.46 12-MAY-21:30 5.60 3.00
June 0.552121E+10 3095.91 17-JUN-06:00 8.90 7.50 0.149772E+10 951.86 16-JUN-21:10 8.90 7.50
July 0.569729E+10 3708.94 31-JUL-04:23 7.20 6.52 0.153263E+10 951.83 14-JUL-21:49 7.20 6.52
August 0.529982E+10 3804.80 28-AUG-04:42 6.38 5.53 0.148288E+10 948.17 02-AUG-21:40 6.38 5.53
September 0.387812E+10 3753.11 03-SEP-01:23 7.20 5.89 0.126777E+10 857.78 01-SEP-21:40 7.20 5.89
October 0.176333E+10 2933.17 03-OCT-23:20 7.80 3.23 0.120599E+10 762.83 03-OCT-21:00 7.80 3.23
November 73676427.99 682.10 01-NOV-21:10 -8.9 -9.5 0.115967E+10 704.50 16-NOV-23:19 -23.9 -24.1
December 22562128.47 520.51 24-DEC-22:00 -5.0 -5.4 0.119883E+10 704.51 19-DEC-01:49 -5.0 -5.4
                     
Annual Sum or Average 0.330464E+11         0.155479E+11        
Minimum of Months 22562128.47 520.51   -9.6 -9.9 0.108387E+10 704.48   -24.4 -24.6
Maximum of Months 0.569729E+10 3831.44   8.90 7.50 0.153263E+10 951.86   8.90 7.50



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 3386337.61 538.32 12-JAN-08:61 -38.2 -38.3 92276376.85 56.69 17-JAN-04:19 -7.2 -7.4
February 5765615.68 481.32 27-FEB-08:61 -34.3 -34.4 83356117.18 56.69 14-FEB-04:19 -34.3 -34.4
March 61643127.71 3165.84 22-MAR-15:02 5.60 2.29 93120422.57 56.69 24-MAR-03:20 -8.0 -8.5
April 0.747899E+09 3610.28 21-APR-18:02 14.22 5.92 93241640.12 56.69 20-APR-21:30 14.22 5.92
May 0.130509E+10 3835.51 31-MAY-15:02 21.28 10.75 98121707.97 56.69 10-MAY-21:10 21.28 10.75
June 0.204328E+10 3894.67 19-JUN-18:02 22.88 12.85 95479906.00 56.70 28-JUN-21:30 19.15 14.83
July 0.198645E+10 3828.00 13-JUL-18:02 23.90 13.18 98543224.76 56.70 19-JUL-21:10 20.82 14.93
August 0.144141E+10 3903.02 10-AUG-18:02 22.62 12.07 98192636.45 56.70 01-AUG-21:30 22.62 12.07
September 0.353837E+09 3524.25 09-SEP-15:02 15.10 8.93 92546558.21 56.69 01-SEP-01:19 15.10 8.93
October 36251398.59 3425.13 03-OCT-15:01 12.62 6.83 92822682.31 56.69 07-OCT-00:49 6.78 3.36
November 3247773.64 402.49 29-NOV-08:61 -29.0 -29.2 89351706.32 56.69 19-NOV-02:20 -29.0 -29.2
December 3065057.00 473.22 15-DEC-08:61 -33.8 -34.0 92200546.27 56.69 16-DEC-00:20 -22.8 -23.0
                     
Annual Sum or Average 0.799132E+10         0.111925E+10        
Minimum of Months 3065057.00 402.49   -38.2 -38.3 83356117.18 56.69   -34.3 -34.4
Maximum of Months 0.204328E+10 3903.02   23.90 13.18 98543224.76 56.70   22.62 14.93



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 3188935.56 538.20 12-JAN-08:61 -38.2 -38.3 92278258.40 56.69 17-JAN-04:19 -7.2 -7.4
February 3521442.79 480.84 27-FEB-08:61 -34.3 -34.4 83350380.46 56.69 21-FEB-04:19 -34.3 -34.4
March 11478845.58 1495.18 20-MAR-15:03 6.52 2.22 92578255.67 56.69 28-MAR-03:20 -15.6 -16.9
April 0.381616E+09 3190.34 21-APR-18:02 14.22 5.92 91690154.92 56.69 20-APR-21:10 14.22 5.92
May 0.909165E+09 3378.44 31-MAY-15:02 21.28 10.75 97436888.65 56.69 30-MAY-21:10 21.28 10.75
June 0.176885E+10 3493.76 19-JUN-18:02 22.88 12.85 95368856.29 56.70 29-JUN-21:10 23.22 16.42
July 0.166982E+10 3432.27 13-JUL-18:02 23.90 13.18 98392616.13 56.70 07-JUL-21:10 23.90 13.18
August 0.101684E+10 3473.77 10-AUG-18:02 22.62 12.07 97596564.55 56.69 01-AUG-21:30 22.62 12.07
September 0.168003E+09 3125.96 02-SEP-18:02 16.52 10.34 91327090.71 56.69 01-SEP-01:19 16.52 10.34
October 18813663.26 1870.68 02-OCT-15:03 8.30 6.13 92429104.06 56.69 06-OCT-01:49 6.93 3.20
November 2991950.60 402.26 29-NOV-08:61 -29.0 -29.2 89352727.70 56.69 24-NOV-04:19 -29.0 -29.2
December 3040301.78 473.18 15-DEC-08:61 -33.8 -34.0 92202182.04 56.69 01-DEC-04:19 -33.8 -34.0
                     
Annual Sum or Average 0.595733E+10         0.111400E+10        
Minimum of Months 2991950.60 402.26   -38.2 -38.3 83350380.46 56.69   -34.3 -34.4
Maximum of Months 0.176885E+10 3493.76   23.90 13.18 98392616.13 56.70   23.90 16.42



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 8657648.37 386.32 12-JAN-08:61 -38.2 -38.3 92323123.24 56.69 10-JAN-04:19 -38.2 -38.3
February 47538081.18 2266.64 15-FEB-16:01 -7.3 -8.7 84504980.11 56.69 09-FEB-00:20 -7.3 -8.7
March 0.285712E+09 2375.35 27-MAR-15:01 -4.9 -8.2 95647853.44 56.69 17-MAR-03:20 -4.9 -8.2
April 0.816901E+09 2447.44 13-APR-15:01 5.10 0.93 94582609.61 56.69 21-APR-21:00 7.20 2.28
May 0.111669E+10 2554.71 31-MAY-15:02 21.28 10.75 98466834.37 56.69 11-MAY-21:00 21.28 10.75
June 0.136409E+10 2549.17 22-JUN-15:02 22.88 11.98 95518314.69 56.70 29-JUN-21:19 23.13 16.41
July 0.144679E+10 2514.92 13-JUL-18:02 23.90 13.18 98618654.53 56.70 19-JUL-21:10 20.82 14.93
August 0.127722E+10 2610.34 10-AUG-15:02 22.30 12.06 98532887.16 56.70 23-AUG-21:10 18.43 14.55
September 0.562689E+09 2420.36 28-SEP-15:01 6.20 2.04 94014571.27 56.69 07-SEP-21:10 6.20 2.04
October 0.158319E+09 2373.93 03-OCT-15:01 12.62 6.83 94565566.53 56.69 05-OCT-21:30 7.50 4.00
November 11912988.52 1256.09 08-NOV-16:01 -16.5 -16.8 89572347.72 56.69 17-NOV-04:19 -20.6 -20.8
December 3986747.20 357.22 24-DEC-09:04 0.18 -1.3 92206569.53 56.69 29-DEC-04:19 -15.8 -16.2
                     
Annual Sum or Average 0.710050E+10         0.112855E+10        
Minimum of Months 3986747.20 357.22   -38.2 -38.3 84504980.11 56.69   -38.2 -38.3
Maximum of Months 0.144679E+10 2610.34   23.90 13.18 98618654.53 56.70   23.13 16.41



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.245689E+11 16009.88 11-JAN-22:08 -34.6 -34.7 0.174419E+11 11347.92 20-JAN-04:19 -8.1 -8.4
February 0.232949E+11 15732.95 08-FEB-23:00 -1.1 -2.8 0.159211E+11 11347.93 10-FEB-04:19 -7.8 -8.6
March 0.277793E+11 21246.79 22-MAR-15:10 5.60 2.29 0.184712E+11 11347.94 12-MAR-23:19 5.60 2.29
April 0.316704E+11 34560.48 22-APR-22:09 6.02 1.74 0.185025E+11 12288.93 18-APR-21:19 6.02 1.74
May 0.385578E+11 33122.64 10-MAY-00:46 6.20 1.31 0.193784E+11 13052.03 29-MAY-23:40 6.13 4.29
June 0.413877E+11 31727.99 19-JUN-04:33 7.43 6.68 0.187762E+11 12620.25 16-JUN-04:19 7.43 6.68
July 0.424703E+11 31499.94 31-JUL-04:33 7.20 6.46 0.193216E+11 12292.07 31-JUL-04:49 7.20 6.41
August 0.397427E+11 35119.39 29-AUG-22:01 4.22 1.11 0.193781E+11 12782.60 29-AUG-01:49 4.22 1.11
September 0.331755E+11 35172.11 14-SEP-22:50 5.78 4.18 0.186246E+11 13074.40 06-SEP-23:00 5.78 4.18
October 0.295029E+11 30995.98 02-OCT-04:45 6.28 4.79 0.188257E+11 12416.87 06-OCT-04:00 6.70 2.79
November 0.239525E+11 14406.11 03-NOV-22:00 -6.1 -7.9 0.169304E+11 11347.90 05-NOV-23:19 -10.0 -10.9
December 0.239710E+11 14890.21 14-DEC-23:53 -30.0 -30.1 0.171632E+11 11347.85 26-DEC-00:20 -10.9 -11.3
                     
Annual Sum or Average 0.380074E+12         0.218735E+12        
Minimum of Months 0.232949E+11 14406.11   -34.6 -34.7 0.159211E+11 11347.85   -10.9 -11.3
Maximum of Months 0.424703E+11 35172.11   7.43 6.68 0.193784E+11 13074.40   7.43 6.68



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.275238E+11 17415.62 11-JAN-22:04 -34.6 -34.7 0.178333E+11 11347.96 17-JAN-00:20 -12.1 -12.3
February 0.260461E+11 17816.42 08-FEB-22:10 0.73 -1.8 0.162551E+11 11348.00 13-FEB-00:20 -14.3 -14.6
March 0.311453E+11 26073.98 22-MAR-15:10 5.60 2.29 0.187553E+11 11347.98 26-MAR-23:19 -17.1 -18.1
April 0.352306E+11 36253.08 22-APR-22:09 6.02 1.74 0.186269E+11 12378.23 18-APR-21:19 6.02 1.74
May 0.420948E+11 37461.70 10-MAY-00:46 6.20 1.31 0.194127E+11 13151.43 29-MAY-23:40 6.13 4.29
June 0.444442E+11 33329.89 19-JUN-04:33 7.43 6.68 0.187827E+11 12696.19 16-JUN-04:19 7.43 6.68
July 0.456069E+11 33549.38 31-JUL-04:33 7.20 6.46 0.193288E+11 12343.10 31-JUL-04:49 7.20 6.41
August 0.430519E+11 36923.83 29-AUG-22:01 4.22 1.11 0.194010E+11 12825.79 29-AUG-01:49 4.22 1.11
September 0.368880E+11 38189.63 14-SEP-22:50 5.78 4.18 0.187119E+11 13187.13 06-SEP-23:00 5.78 4.18
October 0.331513E+11 32672.51 02-OCT-04:45 6.28 4.79 0.190507E+11 12518.83 04-OCT-00:10 7.62 3.01
November 0.268145E+11 16381.80 03-NOV-22:00 -6.1 -7.9 0.173377E+11 11347.98 05-NOV-23:19 -10.0 -10.9
December 0.268048E+11 15911.40 14-DEC-23:53 -30.0 -30.1 0.175830E+11 11347.95 26-DEC-04:19 -12.6 -12.9
                     
Annual Sum or Average 0.418802E+12         0.221079E+12        
Minimum of Months 0.260461E+11 15911.40   -34.6 -34.7 0.162551E+11 11347.95   -17.1 -18.1
Maximum of Months 0.456069E+11 38189.63   7.43 6.68 0.194127E+11 13187.13   7.62 6.68



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.423371E+11 24415.53 22-JAN-11:50 -6.6 -6.9 0.187293E+11 11319.71 14-JAN-18:19 -6.6 -6.9
February 0.398158E+11 26087.29 09-FEB-11:50 -2.0 -2.3 0.169354E+11 11319.71 18-FEB-18:19 -15.4 -16.7
March 0.474829E+11 36765.44 22-MAR-10:35 2.43 0.50 0.187839E+11 11319.69 04-MAR-18:19 2.43 0.50
April 0.501956E+11 40564.27 23-APR-08:62 6.97 1.91 0.182291E+11 11391.90 12-APR-16:49 6.97 1.91
May 0.563635E+11 36257.60 26-MAY-17:30 4.40 2.32 0.188696E+11 11357.48 27-MAY-17:30 9.75 3.95
June 0.565797E+11 35287.28 02-JUN-06:00 6.70 4.48 0.182602E+11 11337.02 24-JUN-17:10 12.20 10.91
July 0.585658E+11 34120.61 05-JUL-07:14 8.50 8.39 0.188620E+11 11319.69 29-JUL-17:19 29.07 18.36
August 0.567012E+11 36556.66 21-AUG-07:31 6.67 5.94 0.188674E+11 11319.69 26-AUG-17:19 20.93 13.69
September 0.507773E+11 36921.13 23-SEP-10:37 3.33 2.21 0.182527E+11 11415.35 23-SEP-17:10 6.60 4.21
October 0.480627E+11 37615.66 03-OCT-10:36 5.37 3.67 0.188162E+11 11479.77 07-OCT-17:49 5.60 3.82
November 0.411884E+11 23963.96 04-NOV-10:50 -8.3 -9.8 0.181408E+11 11319.71 25-NOV-18:19 -21.3 -21.6
December 0.414736E+11 24577.52 24-DEC-11:50 1.60 -0.2 0.187299E+11 11319.71 16-DEC-18:19 1.60 -0.2
                     
Annual Sum or Average 0.589544E+12         0.221476E+12        
Minimum of Months 0.398158E+11 23963.96   -8.3 -9.8 0.169354E+11 11319.69   -21.3 -21.6
Maximum of Months 0.585658E+11 40564.27   8.50 8.39 0.188696E+11 11479.77   29.07 18.36



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 2771579.57 339.01 21-JAN-21:30 -1.9 -3.2 0.126867E+10 745.71 13-JAN-02:49 -1.9 -3.2
February 0.189205E+09 2368.97 09-FEB-13:30 -0.3 -1.5 0.114714E+10 745.74 18-FEB-05:19 -23.5 -23.8
March 0.187111E+10 4836.67 22-MAR-15:03 5.60 2.29 0.127648E+10 771.76 22-MAR-21:40 1.87 0.05
April 0.649387E+10 6606.45 23-APR-08:62 6.97 1.91 0.130034E+10 894.02 21-APR-21:30 6.97 1.91
May 0.972340E+10 7296.21 18-MAY-00:52 5.60 3.00 0.149044E+10 970.96 31-MAY-21:30 16.00 9.64
June 0.109770E+11 6397.78 30-JUN-12:40 26.33 17.53 0.156415E+10 1007.38 22-JUN-21:10 26.33 17.53
July 0.114139E+11 7124.32 23-JUL-13:40 25.00 15.26 0.160518E+10 1007.39 20-JUL-21:10 25.00 15.26
August 0.103574E+11 7235.64 28-AUG-04:42 6.38 5.53 0.153915E+10 1003.05 02-AUG-21:30 6.38 5.53
September 0.719236E+10 7141.04 03-SEP-01:23 7.20 5.89 0.130701E+10 864.46 01-SEP-21:40 7.20 5.89
October 0.275288E+10 5745.67 03-OCT-23:20 7.80 3.23 0.127468E+10 808.57 03-OCT-21:00 7.80 3.23
November 2080444.96 199.44 01-NOV-21:10 -8.9 -9.5 0.122735E+10 745.74 16-NOV-23:49 -23.9 -24.1
December 2902333.63 340.57 24-DEC-23:00 -3.3 -3.7 0.126880E+10 745.75 19-DEC-01:00 -3.3 -3.7
                     
Annual Sum or Average 0.609789E+11         0.162694E+11        
Minimum of Months 2080444.96 199.44   -8.9 -9.5 0.114714E+10 745.71   -23.9 -24.1
Maximum of Months 0.114139E+11 7296.21   26.33 17.53 0.160518E+10 1007.39   26.33 17.53



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9
February 0.00 0.00 01-FEB-00:03 -20.2
March 2541100.84 2542.19 22-MAR-14:30 5.60
April 13276434.26 1943.52 18-APR-14:10 6.70
May 29853321.03 2005.88 15-MAY-02:28 6.40
June 4767816.59 1789.47 01-JUN-03:44 6.93
July 43860.71 184.74 31-JUL-03:06 7.20
August 0.00 0.00 01-AUG-00:05 16.35
September 7271.76 48.48 03-SEP-05:20 6.13
October 0.00 0.00 01-OCT-00:10 1.42
November 0.00 0.00 01-NOV-00:05 -10.0
December 0.00 0.00 01-DEC-00:02 -25.8
         
Annual Sum or Average 50489805.19      
Minimum of Months 0.00 0.00   -25.8
Maximum of Months 29853321.03 2542.19   16.35



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.396717E+10 3202.58 13-JAN-10:50 -30.7
February 0.211123E+10 2462.06 27-FEB-08:10 -34.3
March 0.809443E+09 2294.86 01-MAR-08:02 -28.1
April 79744969.15 976.87 03-APR-06:05 -21.5
May 30106867.10 876.88 20-MAY-00:44 6.28
June 7072012.13 845.06 07-JUN-03:18 6.33
July 6195507.77 804.69 31-JUL-03:06 7.20
August 11302551.54 913.64 29-AUG-22:04 4.22
September 56266515.61 904.31 03-SEP-05:20 6.13
October 0.621704E+09 1603.60 30-OCT-08:30 -16.7
November 0.337217E+10 2856.09 29-NOV-10:20 -29.4
December 0.478380E+10 3103.97 15-DEC-15:00 -30.6
         
Annual Sum or Average 0.158562E+11      
Minimum of Months 6195507.77 804.69   -34.3
Maximum of Months 0.478380E+10 3202.58   7.20



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 42840333.73 468.37 13-JAN-11:00 -30.6
February 4441562.16 157.94 27-FEB-11:00 -33.3
March 154255.91 201.13 22-MAR-14:30 5.60
April 298907.66 130.14 16-APR-14:55 6.10
May 222888.46 133.93 28-MAY-07:29 5.25
June 2171.44 28.35 07-JUN-03:18 6.33
July 6531.17 18.08 06-JUL-03:17 7.80
August 109368.26 96.26 20-AUG-03:14 6.67
September 1401199.40 219.90 25-SEP-15:15 5.40
October 693538.39 178.57 02-OCT-08:53 5.60
November 9206188.55 240.17 29-NOV-10:20 -29.4
December 66688575.94 385.08 15-DEC-11:01 -33.3
         
Annual Sum or Average 0.126066E+09      
Minimum of Months 2171.44 18.08   -33.3
Maximum of Months 66688575.94 468.37   7.80



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.150061E+10 1621.92 12-JAN-16:00 -35.6
February 0.104341E+10 1365.38 27-FEB-05:00 -36.1
March 0.485479E+09 1230.34 01-MAR-05:00 -28.3
April 29642393.76 390.27 03-APR-04:00 -21.1
May 2828552.90 218.28 01-MAY-04:59 7.20
June 170003.66 115.63 01-JUN-03:44 6.93
July 167734.46 98.09 06-JUL-03:17 7.80
August 666722.94 156.75 20-AUG-03:14 6.67
September 7111980.53 315.18 25-SEP-15:15 5.40
October 0.148761E+09 492.61 31-OCT-10:03 -16.5
November 0.123118E+10 1241.63 30-NOV-04:50 -27.9
December 0.176725E+10 1379.18 15-DEC-13:50 -32.3
         
Annual Sum or Average 0.621727E+10      
Minimum of Months 167734.46 98.09   -36.1
Maximum of Months 0.176725E+10 1621.92   7.80



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.156513E+10 1206.26 13-JAN-11:03 -30.6
February 0.114367E+10 1024.36 27-FEB-05:00 -36.1
March 0.659211E+09 919.56 01-MAR-05:00 -28.3
April 69510555.29 389.27 03-APR-08:03 -17.1
May 2189185.97 126.70 28-MAY-07:29 5.25
June 151778.27 63.61 01-JUN-03:44 6.93
July 139339.30 58.12 06-JUL-03:17 7.80
August 557699.45 98.02 20-AUG-03:14 6.67
September 5255199.60 159.91 25-SEP-15:15 5.40
October 0.275334E+09 515.93 31-OCT-09:30 -16.9
November 0.137405E+10 1012.11 30-NOV-11:00 -28.9
December 0.175538E+10 1119.46 15-DEC-14:10 -31.9
         
Annual Sum or Average 0.685058E+10      
Minimum of Months 139339.30 58.12   -36.1
Maximum of Months 0.175538E+10 1206.26   7.80



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9
February 0.00 0.00 01-FEB-00:03 -20.2
March 0.00 0.00 01-MAR-00:03 -28.9
April 0.00 0.00 01-APR-00:10 -11.7
May 1788318.27 1374.84 09-MAY-01:32 5.97
June 1357241.09 2357.79 07-JUN-03:18 6.33
July 1072944.39 1692.58 31-JUL-03:13 7.20
August 1237563.17 1936.97 29-AUG-03:50 7.20
September 3177042.28 2096.84 02-SEP-04:49 6.70
October 1297553.01 2003.39 02-OCT-03:28 6.65
November 0.00 0.00 01-NOV-00:05 -10.0
December 0.00 0.00 01-DEC-00:02 -25.8
         
Annual Sum or Average 9930662.21      
Minimum of Months 0.00 0.00   -28.9
Maximum of Months 3177042.28 2357.79   7.20



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.144814E+10 5395.21 13-JAN-10:50 -30.7
February 0.171658E+09 2401.99 01-FEB-09:50 -17.0
March 11183488.94 1703.31 01-MAR-08:10 -28.1
April 2129294.44 1463.52 20-APR-08:18 5.97
May 6901646.14 2511.94 04-MAY-06:35 5.03
June 84092.72 533.14 07-JUN-03:18 6.33
July 86975.92 331.00 17-JUL-06:00 8.30
August 5315908.51 2196.26 21-AUG-06:55 5.60
September 43655245.98 2583.04 06-SEP-07:29 6.15
October 20739224.52 2567.48 02-OCT-08:53 5.60
November 0.847694E+09 4810.99 29-NOV-10:20 -29.4
December 0.238495E+10 5428.05 15-DEC-15:00 -30.6
         
Annual Sum or Average 0.494253E+10      
Minimum of Months 84092.72 331.00   -30.7
Maximum of Months 0.238495E+10 5428.05   8.30



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.165825E+09 5809.19 13-JAN-10:50 -30.7
February 550497.91 511.97 27-FEB-15:00 -28.3
March 841059.02 2006.37 22-MAR-14:06 5.60
April 365008.72 1184.37 16-APR-14:55 6.10
May 1047512.60 1956.02 04-MAY-06:35 5.03
June 0.00 0.00 01-JUN-00:05 12.17
July 0.00 0.00 01-JUL-00:10 14.88
August 230577.52 862.98 21-AUG-06:55 5.60
September 10042082.46 2947.84 21-SEP-14:15 6.47
October 2295495.61 3794.22 02-OCT-08:53 5.60
November 24880803.83 2603.07 29-NOV-10:15 -29.4
December 0.310570E+09 4922.71 15-DEC-14:40 -31.1
         
Annual Sum or Average 0.516648E+09      
Minimum of Months 0.00 0.00   -31.1
Maximum of Months 0.310570E+09 5809.19   14.88



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.351569E+10 3932.07 13-JAN-19:01 -19.8
February 0.250548E+10 3904.37 25-FEB-16:01 -21.8
March 0.165358E+10 3866.79 15-MAR-08:61 -22.4
April 0.370045E+09 3836.67 03-APR-08:61 -17.1
May 17199395.94 1372.11 27-MAY-08:62 0.68
June 909617.97 829.05 02-JUN-08:03 10.55
July 843604.87 783.71 30-JUL-08:04 15.00
August 8443706.24 1933.38 30-AUG-08:62 2.07
September 0.249086E+09 3770.32 30-SEP-08:61 -5.0
October 0.141094E+10 3882.92 30-OCT-08:61 -16.7
November 0.317863E+10 3932.83 26-NOV-16:01 -22.4
December 0.383939E+10 3927.08 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.167502E+11      
Minimum of Months 843604.87 783.71   -23.3
Maximum of Months 0.383939E+10 3932.83   15.00



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.362499E+10 3828.43 30-JAN-16:01 -22.9
February 0.283941E+10 3811.27 25-FEB-16:01 -21.8
March 0.212842E+10 3798.86 03-MAR-09:01 -21.0
April 0.550578E+09 3749.31 03-APR-08:61 -17.1
May 23857322.52 1554.04 27-MAY-08:62 0.68
June 820757.70 508.49 26-JUN-08:04 13.07
July 930820.28 805.50 30-JUL-08:04 15.00
August 14887806.72 2485.30 30-AUG-08:62 2.07
September 0.349729E+09 3696.72 30-SEP-08:61 -5.0
October 0.167230E+10 3783.98 27-OCT-08:61 -18.2
November 0.336124E+10 3833.55 26-NOV-16:01 -22.4
December 0.387354E+10 3820.48 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.184407E+11      
Minimum of Months 820757.70 508.49   -23.3
Maximum of Months 0.387354E+10 3833.55   15.00



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.755911E+09 580.22 12-JAN-04:05 -37.3
February 0.351910E+09 450.58 27-FEB-06:00 -36.1
March 84011086.34 413.94 01-MAR-05:00 -28.3
April 0.00 0.00 01-APR-00:10 -11.7
May 0.00 0.00 01-MAY-00:03 6.70
June 0.00 0.00 01-JUN-00:05 12.17
July 0.00 0.00 01-JUL-00:10 14.88
August 0.00 0.00 01-AUG-00:05 16.35
September 294188.33 36.07 28-SEP-05:00 -2.2
October 0.111884E+09 298.63 22-OCT-05:00 -20.0
November 0.616456E+09 474.09 29-NOV-05:00 -28.9
December 0.908976E+09 544.15 15-DEC-05:00 -33.3
         
Annual Sum or Average 0.282944E+10      
Minimum of Months 0.00 0.00   -37.3
Maximum of Months 0.908976E+09 580.22   16.35



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.746744E+09 1094.66 30-JAN-16:01 -22.9
February 0.582880E+09 1093.15 28-FEB-16:01 -22.4
March 0.422559E+09 1090.30 01-MAR-16:01 -12.8
April 91536927.02 1079.91 02-APR-15:01 -6.8
May 722314.16 401.48 21-MAY-15:05 15.68
June 121053.28 205.98 27-JUN-08:06 13.40
July 167253.74 200.22 25-JUL-08:06 13.90
August 538196.37 421.03 07-AUG-15:04 17.38
September 16300026.02 1039.98 29-SEP-08:61 -4.4
October 0.245695E+09 1087.24 31-OCT-15:01 -11.6
November 0.695457E+09 1095.39 26-NOV-16:01 -22.4
December 0.813362E+09 1089.16 28-DEC-16:02 -21.5
         
Annual Sum or Average 0.361608E+10      
Minimum of Months 121053.28 200.22   -22.9
Maximum of Months 0.813362E+09 1095.39   17.38



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.347824E+10 3870.22 13-JAN-19:01 -19.8
February 0.236496E+10 3847.70 25-FEB-16:01 -21.8
March 0.138240E+10 3800.16 01-MAR-19:01 -19.7
April 0.363786E+09 3758.12 04-APR-08:61 -8.0
May 10851292.27 1097.88 26-MAY-18:02 4.32
June 493766.43 458.40 25-JUN-08:05 10.00
July 360356.27 560.45 17-JUL-15:04 17.02
August 5399882.29 782.29 29-AUG-08:03 7.38
September 0.199760E+09 3611.26 27-SEP-15:01 3.40
October 0.126133E+10 3822.99 30-OCT-08:61 -16.7
November 0.317222E+10 3872.53 26-NOV-16:01 -22.4
December 0.383201E+10 3866.22 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.160718E+11      
Minimum of Months 360356.27 458.40   -23.3
Maximum of Months 0.383201E+10 3872.53   17.02



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.358506E+10 3766.12 13-JAN-19:01 -19.8
February 0.268489E+10 3759.03 25-FEB-16:01 -21.8
March 0.179306E+10 3727.70 01-MAR-19:01 -19.7
April 0.552301E+09 3668.15 04-APR-08:61 -8.0
May 16040450.45 804.06 28-MAY-08:03 6.57
June 711458.62 461.27 24-JUN-08:05 12.30
July 497900.79 515.82 01-JUL-08:05 12.80
August 9500172.26 695.31 20-AUG-18:03 17.62
September 0.279806E+09 3593.03 25-SEP-15:01 5.50
October 0.149406E+10 3726.18 27-OCT-08:61 -18.2
November 0.335468E+10 3774.52 26-NOV-16:01 -22.4
December 0.386535E+10 3761.45 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.176359E+11      
Minimum of Months 497900.79 461.27   -23.3
Maximum of Months 0.386535E+10 3774.52   17.62



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.195950E+10 2309.20 13-JAN-15:00 -25.6
February 0.826952E+09 1565.61 27-FEB-16:00 -27.2
March 0.120576E+09 1237.36 01-MAR-08:02 -28.1
April 6307716.15 398.07 10-APR-14:45 6.60
May 3211357.48 368.09 28-MAY-07:29 5.25
June 104534.12 158.74 01-JUN-03:44 6.93
July 253485.97 175.46 06-JUL-03:17 7.80
August 1634226.53 397.99 20-AUG-03:14 6.67
September 19867467.73 599.77 25-SEP-15:15 5.40
October 0.138787E+09 937.33 30-OCT-08:03 -16.7
November 0.152844E+10 1927.36 29-NOV-10:20 -29.4
December 0.248337E+10 2380.89 15-DEC-15:00 -30.6
         
Annual Sum or Average 0.708901E+10      
Minimum of Months 104534.12 158.74   -30.6
Maximum of Months 0.248337E+10 2380.89   7.80



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.460831E+10 4599.57 13-JAN-19:01 -19.8
February 0.337762E+10 4564.45 25-FEB-16:01 -21.8
March 0.233086E+10 4525.77 15-MAR-08:61 -22.4
April 0.620741E+09 4480.80 03-APR-08:61 -17.1
May 64014789.44 2979.27 27-MAY-08:62 0.68
June 1260994.69 675.68 02-JUN-08:03 10.55
July 3320912.61 953.19 04-JUL-08:03 9.40
August 29926626.88 3817.35 30-AUG-08:62 2.07
September 0.477429E+09 4399.46 30-SEP-08:61 -5.0
October 0.202365E+10 4538.11 27-OCT-08:61 -18.2
November 0.421562E+10 4602.11 26-NOV-16:01 -22.4
December 0.498883E+10 4595.07 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.227416E+11      
Minimum of Months 1260994.69 675.68   -23.3
Maximum of Months 0.498883E+10 4602.11   10.55



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.472879E+10 4451.50 30-JAN-16:01 -22.9
February 0.375584E+10 4429.33 25-FEB-16:01 -21.8
March 0.291074E+10 4414.86 03-MAR-09:01 -21.0
April 0.883464E+09 4355.56 03-APR-08:61 -17.1
May 85406140.02 3212.59 27-MAY-08:62 0.68
June 1220365.50 657.53 02-JUN-08:03 10.55
July 2909626.17 849.71 04-JUL-08:03 9.40
August 45574379.38 4093.58 31-AUG-08:62 2.48
September 0.647796E+09 4274.62 30-SEP-08:61 -5.0
October 0.234165E+10 4395.56 27-OCT-08:61 -18.2
November 0.442243E+10 4456.73 26-NOV-16:01 -22.4
December 0.502593E+10 4440.91 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.248518E+11      
Minimum of Months 1220365.50 657.53   -23.3
Maximum of Months 0.502593E+10 4456.73   10.55



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.206153E+10 2564.44 13-JAN-19:01 -19.8
February 0.122811E+10 2545.94 01-FEB-16:01 -12.2
March 0.688044E+09 2505.22 13-MAR-08:61 -23.0
April 0.139458E+09 2494.36 03-APR-08:61 -17.1
May 8422537.91 773.54 26-MAY-18:02 4.32
June 747158.24 503.43 02-JUN-08:03 10.55
July 786467.14 548.80 17-JUL-08:03 12.15
August 3036256.62 775.95 30-AUG-08:62 2.07
September 80705610.42 2413.51 28-SEP-08:61 -2.0
October 0.625853E+09 2528.66 30-OCT-08:61 -16.7
November 0.178960E+10 2559.11 26-NOV-16:01 -22.4
December 0.236012E+10 2563.64 12-DEC-19:01 -23.3
         
Annual Sum or Average 0.898641E+10      
Minimum of Months 747158.24 503.43   -23.3
Maximum of Months 0.236012E+10 2564.44   12.15



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9
February 0.00 0.00 01-FEB-00:03 -20.2
March 0.00 0.00 01-MAR-00:03 -28.9
April 0.00 0.00 01-APR-00:10 -11.7
May 0.00 0.00 01-MAY-00:03 6.70
June 0.00 0.00 01-JUN-00:05 12.17
July 0.00 0.00 01-JUL-00:10 14.88
August 0.00 0.00 01-AUG-00:05 16.35
September 0.00 0.00 01-SEP-00:05 8.08
October 27432.92 457.22 02-OCT-08:53 5.60
November 0.00 0.00 01-NOV-00:05 -10.0
December 0.00 0.00 01-DEC-00:02 -25.8
         
Annual Sum or Average 27432.92      
Minimum of Months 0.00 0.00   -28.9
Maximum of Months 27432.92 457.22   16.35



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9
February 0.00 0.00 01-FEB-00:03 -20.2
March 0.00 0.00 01-MAR-00:03 -28.9
April 0.00 0.00 01-APR-00:10 -11.7
May 0.00 0.00 01-MAY-00:03 6.70
June 0.00 0.00 01-JUN-00:05 12.17
July 0.00 0.00 01-JUL-00:10 14.88
August 0.00 0.00 01-AUG-00:05 16.35
September 0.00 0.00 01-SEP-00:05 8.08
October 2972.55 49.54 02-OCT-08:53 5.60
November 0.00 0.00 01-NOV-00:05 -10.0
December 0.00 0.00 01-DEC-00:02 -25.8
         
Annual Sum or Average 2972.55      
Minimum of Months 0.00 0.00   -28.9
Maximum of Months 2972.55 49.54   16.35



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 -14.9
February 0.00 0.00 01-FEB-00:03 -20.2
March 0.00 0.00 01-MAR-00:03 -28.9
April 0.00 0.00 01-APR-00:10 -11.7
May 0.00 0.00 01-MAY-00:03 6.70
June 0.00 0.00 01-JUN-00:05 12.17
July 0.00 0.00 01-JUL-00:10 14.88
August 0.00 0.00 01-AUG-00:05 16.35
September 0.00 0.00 01-SEP-00:05 8.08
October 0.00 0.00 01-OCT-00:10 1.42
November 0.00 0.00 01-NOV-00:05 -10.0
December 0.00 0.00 01-DEC-00:02 -25.8
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   -28.9
Maximum of Months 0.00 0.00   16.35



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.744769E+10 6961.76 12-JAN-16:00 -35.6
February 0.422264E+10 5819.85 27-FEB-07:10 -34.9
March 0.142250E+10 5127.11 01-MAR-07:10 -28.8
April 0.116748E+09 2020.19 03-APR-06:10 -21.5
May 13782401.92 1035.40 28-MAY-07:29 5.25
June 617311.97 427.30 07-JUN-03:18 6.33
July 1419012.38 529.86 06-JUL-03:17 7.80
August 5999867.64 988.88 20-AUG-03:14 6.67
September 52387051.43 1171.61 21-SEP-06:28 6.40
October 0.743719E+09 2711.15 27-OCT-08:15 -18.5
November 0.659400E+10 6068.96 29-NOV-10:20 -29.4
December 0.894242E+10 6658.06 15-DEC-11:09 -33.3
         
Annual Sum or Average 0.295639E+11      
Minimum of Months 617311.97 427.30   -35.6
Maximum of Months 0.894242E+10 6961.76   7.80



Table of Contents

Report: ZoneElectricSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.147273E+11 14185.34 02-JAN-20:10 0.127587E+11 10113.80 02-JAN-20:10
February 0.132974E+11 14185.34 01-FEB-20:10 0.115208E+11 10113.80 01-FEB-20:10
March 0.147727E+11 14185.34 01-MAR-20:10 0.127855E+11 10113.80 01-MAR-20:10
April 0.142280E+11 14185.34 03-APR-19:10 0.123314E+11 10113.80 03-APR-19:10
May 0.147528E+11 14185.34 01-MAY-19:10 0.127741E+11 10113.80 01-MAY-19:10
June 0.142932E+11 14185.34 01-JUN-19:10 0.123716E+11 10113.80 01-JUN-19:10
July 0.146876E+11 14185.34 03-JUL-19:10 0.127338E+11 10113.80 03-JUL-19:10
August 0.147784E+11 14185.34 01-AUG-19:10 0.127894E+11 10113.80 01-AUG-19:10
September 0.142337E+11 14185.34 01-SEP-19:10 0.123352E+11 10113.80 01-SEP-19:10
October 0.147216E+11 14185.34 02-OCT-19:10 0.127549E+11 10113.80 02-OCT-19:10
November 0.142819E+11 14185.34 01-NOV-19:10 0.123659E+11 10113.80 01-NOV-19:10
December 0.146876E+11 14185.34 01-DEC-20:10 0.127338E+11 10113.80 01-DEC-20:10
             
Annual Sum or Average 0.173462E+12     0.150255E+12    
Minimum of Months 0.132974E+11 14185.34   0.115208E+11 10113.80  
Maximum of Months 0.147784E+11 14185.34   0.127894E+11 10113.80  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.731324E+09 704.41 02-JAN-20:10 0.864900E+09 685.60 02-JAN-20:10
February 0.660319E+09 704.41 01-FEB-20:10 0.780982E+09 685.60 01-FEB-20:10
March 0.733578E+09 704.41 01-MAR-20:10 0.866718E+09 685.60 01-MAR-20:10
April 0.706528E+09 704.41 03-APR-19:10 0.835931E+09 685.60 03-APR-19:10
May 0.732592E+09 704.41 01-MAY-19:10 0.865939E+09 685.60 01-MAY-19:10
June 0.709769E+09 704.41 01-JUN-19:10 0.838659E+09 685.60 01-JUN-19:10
July 0.729351E+09 704.41 03-JUL-19:10 0.863211E+09 685.60 03-JUL-19:10
August 0.733860E+09 704.41 01-AUG-19:10 0.866978E+09 685.60 01-AUG-19:10
September 0.706810E+09 704.41 01-SEP-19:10 0.836191E+09 685.60 01-SEP-19:10
October 0.731042E+09 704.41 02-OCT-19:10 0.864640E+09 685.60 02-OCT-19:10
November 0.709205E+09 704.41 01-NOV-19:10 0.838269E+09 685.60 01-NOV-19:10
December 0.729351E+09 704.41 01-DEC-20:10 0.863211E+09 685.60 01-DEC-20:10
             
Annual Sum or Average 0.861373E+10     0.101856E+11    
Minimum of Months 0.660319E+09 704.41   0.780982E+09 685.60  
Maximum of Months 0.733860E+09 704.41   0.866978E+09 685.60  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.846876E+09 815.72 02-JAN-20:10 0.100156E+10 793.93 02-JAN-20:10
February 0.764651E+09 815.72 01-FEB-20:10 0.904380E+09 793.93 01-FEB-20:10
March 0.849486E+09 815.72 01-MAR-20:10 0.100366E+10 793.93 01-MAR-20:10
April 0.818162E+09 815.72 03-APR-19:10 0.968011E+09 793.93 03-APR-19:10
May 0.848344E+09 815.72 01-MAY-19:10 0.100276E+10 793.93 01-MAY-19:10
June 0.821915E+09 815.72 01-JUN-19:10 0.971170E+09 793.93 01-JUN-19:10
July 0.844592E+09 815.72 03-JUL-19:10 0.999601E+09 793.93 03-JUL-19:10
August 0.849812E+09 815.72 01-AUG-19:10 0.100396E+10 793.93 01-AUG-19:10
September 0.818489E+09 815.72 01-SEP-19:10 0.968312E+09 793.93 01-SEP-19:10
October 0.846549E+09 815.72 02-OCT-19:10 0.100126E+10 793.93 02-OCT-19:10
November 0.821262E+09 815.72 01-NOV-19:10 0.970719E+09 793.93 01-NOV-19:10
December 0.844592E+09 815.72 01-DEC-20:10 0.999601E+09 793.93 01-DEC-20:10
             
Annual Sum or Average 0.997473E+10     0.117950E+11    
Minimum of Months 0.764651E+09 815.72   0.904380E+09 793.93  
Maximum of Months 0.849812E+09 815.72   0.100396E+10 793.93  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.141236E+10 1360.40 02-JAN-20:10 0.105898E+10 839.45 02-JAN-20:10
February 0.127524E+10 1360.40 01-FEB-20:10 0.956227E+09 839.45 01-FEB-20:10
March 0.141672E+10 1360.40 01-MAR-20:10 0.106120E+10 839.45 01-MAR-20:10
April 0.136448E+10 1360.40 03-APR-19:10 0.102351E+10 839.45 03-APR-19:10
May 0.141481E+10 1360.40 01-MAY-19:10 0.106025E+10 839.45 01-MAY-19:10
June 0.137074E+10 1360.40 01-JUN-19:10 0.102685E+10 839.45 01-JUN-19:10
July 0.140855E+10 1360.40 03-JUL-19:10 0.105691E+10 839.45 03-JUL-19:10
August 0.141726E+10 1360.40 01-AUG-19:10 0.106152E+10 839.45 01-AUG-19:10
September 0.136502E+10 1360.40 01-SEP-19:10 0.102382E+10 839.45 01-SEP-19:10
October 0.141182E+10 1360.40 02-OCT-19:10 0.105866E+10 839.45 02-OCT-19:10
November 0.136965E+10 1360.40 01-NOV-19:10 0.102637E+10 839.45 01-NOV-19:10
December 0.140855E+10 1360.40 01-DEC-20:10 0.105691E+10 839.45 01-DEC-20:10
             
Annual Sum or Average 0.166352E+11     0.124712E+11    
Minimum of Months 0.127524E+10 1360.40   0.956227E+09 839.45  
Maximum of Months 0.141726E+10 1360.40   0.106152E+10 839.45  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.236418E+09 227.72 02-JAN-20:10 0.305485E+09 242.16 02-JAN-20:10
February 0.213464E+09 227.72 01-FEB-20:10 0.275845E+09 242.16 01-FEB-20:10
March 0.237147E+09 227.72 01-MAR-20:10 0.306128E+09 242.16 01-MAR-20:10
April 0.228402E+09 227.72 03-APR-19:10 0.295253E+09 242.16 03-APR-19:10
May 0.236828E+09 227.72 01-MAY-19:10 0.305852E+09 242.16 01-MAY-19:10
June 0.229450E+09 227.72 01-JUN-19:10 0.296217E+09 242.16 01-JUN-19:10
July 0.235780E+09 227.72 03-JUL-19:10 0.304889E+09 242.16 03-JUL-19:10
August 0.237238E+09 227.72 01-AUG-19:10 0.306219E+09 242.16 01-AUG-19:10
September 0.228493E+09 227.72 01-SEP-19:10 0.295345E+09 242.16 01-SEP-19:10
October 0.236327E+09 227.72 02-OCT-19:10 0.305393E+09 242.16 02-OCT-19:10
November 0.229268E+09 227.72 01-NOV-19:10 0.296079E+09 242.16 01-NOV-19:10
December 0.235780E+09 227.72 01-DEC-20:10 0.304889E+09 242.16 01-DEC-20:10
             
Annual Sum or Average 0.278459E+10     0.359760E+10    
Minimum of Months 0.213464E+09 227.72   0.275845E+09 242.16  
Maximum of Months 0.237238E+09 227.72   0.306219E+09 242.16  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.370859E+09 357.21 02-JAN-20:10 0.576866E+10 4572.80 02-JAN-20:10
February 0.334852E+09 357.21 01-FEB-20:10 0.520895E+10 4572.80 01-FEB-20:10
March 0.372002E+09 357.21 01-MAR-20:10 0.578079E+10 4572.80 01-MAR-20:10
April 0.358285E+09 357.21 03-APR-19:10 0.557545E+10 4572.80 03-APR-19:10
May 0.371502E+09 357.21 01-MAY-19:10 0.577559E+10 4572.80 01-MAY-19:10
June 0.359929E+09 357.21 01-JUN-19:10 0.559364E+10 4572.80 01-JUN-19:10
July 0.369859E+09 357.21 03-JUL-19:10 0.575740E+10 4572.80 03-JUL-19:10
August 0.372145E+09 357.21 01-AUG-19:10 0.578252E+10 4572.80 01-AUG-19:10
September 0.358428E+09 357.21 01-SEP-19:10 0.557718E+10 4572.80 01-SEP-19:10
October 0.370717E+09 357.21 02-OCT-19:10 0.576693E+10 4572.80 02-OCT-19:10
November 0.359643E+09 357.21 01-NOV-19:10 0.559104E+10 4572.80 01-NOV-19:10
December 0.369859E+09 357.21 01-DEC-20:10 0.575740E+10 4572.80 01-DEC-20:10
             
Annual Sum or Average 0.436808E+10     0.679355E+11    
Minimum of Months 0.334852E+09 357.21   0.520895E+10 4572.80  
Maximum of Months 0.372145E+09 357.21   0.578252E+10 4572.80  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.175838E+10 1761.91 02-JAN-20:10 0.121771E+10 965.27 02-JAN-20:10
February 0.150663E+10 1761.91 01-FEB-20:10 0.109956E+10 965.27 01-FEB-20:10
March 0.156853E+10 1761.91 01-MAR-20:10 0.122027E+10 965.27 01-MAR-20:10
April 0.133560E+10 1761.91 03-APR-19:30 0.117692E+10 965.27 03-APR-19:10
May 0.131501E+10 1761.91 02-MAY-19:00 0.121917E+10 965.27 01-MAY-19:10
June 0.121172E+10 1566.14 02-JUN-20:49 0.118076E+10 965.27 01-JUN-19:10
July 0.127133E+10 1566.14 17-JUL-20:00 0.121533E+10 965.27 03-JUL-19:10
August 0.138099E+10 1761.91 17-AUG-19:00 0.122063E+10 965.27 01-AUG-19:10
September 0.146907E+10 1761.91 01-SEP-19:10 0.117729E+10 965.27 01-SEP-19:10
October 0.163798E+10 1761.91 02-OCT-19:10 0.121734E+10 965.27 02-OCT-19:10
November 0.166694E+10 1761.91 01-NOV-19:10 0.118021E+10 965.27 01-NOV-19:10
December 0.179438E+10 1761.91 01-DEC-20:10 0.121533E+10 965.27 01-DEC-20:10
             
Annual Sum or Average 0.179166E+11     0.143405E+11    
Minimum of Months 0.121172E+10 1566.14   0.109956E+10 965.27  
Maximum of Months 0.179438E+10 1761.91   0.122063E+10 965.27  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.105901E+11 10265.18 02-JAN-20:10 0.126520E+11 10029.21 02-JAN-20:10
February 0.947482E+10 10265.18 01-FEB-20:10 0.114244E+11 10029.21 01-FEB-20:10
March 0.104188E+11 10265.18 01-MAR-20:10 0.126786E+11 10029.21 01-MAR-20:10
April 0.986187E+10 10265.18 03-APR-19:19 0.122282E+11 10029.21 03-APR-19:10
May 0.101589E+11 10265.18 02-MAY-19:49 0.126672E+11 10029.21 01-MAY-19:10
June 0.977822E+10 10025.66 02-JUN-19:30 0.122682E+11 10029.21 01-JUN-19:10
July 0.100752E+11 10025.66 24-JUL-19:49 0.126273E+11 10029.21 03-JUL-19:10
August 0.102430E+11 10265.18 07-AUG-19:00 0.126824E+11 10029.21 01-AUG-19:10
September 0.999925E+10 10265.18 01-SEP-19:10 0.122320E+11 10029.21 01-SEP-19:10
October 0.104600E+11 10265.18 02-OCT-19:10 0.126482E+11 10029.21 02-OCT-19:10
November 0.102306E+11 10265.18 01-NOV-19:10 0.122624E+11 10029.21 01-NOV-19:10
December 0.106063E+11 10265.18 01-DEC-20:10 0.126273E+11 10029.21 01-DEC-20:10
             
Annual Sum or Average 0.121897E+12     0.148998E+12    
Minimum of Months 0.947482E+10 10025.66   0.114244E+11 10029.21  
Maximum of Months 0.106063E+11 10265.18   0.126824E+11 10029.21  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135397E+09 122.50 01-JAN-19:10 0.261068E+09 237.06 01-JAN-08:09
February 0.122277E+09 122.50 01-FEB-20:10 0.235798E+09 237.06 01-FEB-07:10
March 0.134321E+09 122.50 01-MAR-20:10 0.260708E+09 237.06 01-MAR-07:10
April 0.131185E+09 122.50 01-APR-18:10 0.252705E+09 237.06 01-APR-07:10
May 0.134859E+09 122.50 01-MAY-19:10 0.260888E+09 237.06 01-MAY-06:10
June 0.130145E+09 122.50 01-JUN-19:10 0.252344E+09 237.06 01-JUN-06:10
July 0.135918E+09 122.50 01-JUL-18:10 0.261248E+09 237.06 01-JUL-07:10
August 0.134321E+09 122.50 01-AUG-19:10 0.260708E+09 237.06 01-AUG-06:10
September 0.131221E+09 122.50 01-SEP-19:10 0.252705E+09 237.06 01-SEP-06:10
October 0.135380E+09 122.50 01-OCT-18:10 0.261068E+09 237.06 01-OCT-07:10
November 0.130665E+09 122.50 01-NOV-19:10 0.252524E+09 237.06 01-NOV-06:10
December 0.135935E+09 122.50 01-DEC-20:10 0.261248E+09 237.06 01-DEC-07:10
             
Annual Sum or Average 0.159162E+10     0.307301E+10    
Minimum of Months 0.122277E+09 122.50   0.235798E+09 237.06  
Maximum of Months 0.135935E+09 122.50   0.261248E+09 237.06  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135381E+09 122.49 01-JAN-19:10 0.261038E+09 237.03 01-JAN-08:09
February 0.122263E+09 122.49 01-FEB-20:10 0.235770E+09 237.03 01-FEB-07:10
March 0.134305E+09 122.49 01-MAR-20:10 0.260677E+09 237.03 01-MAR-07:10
April 0.131170E+09 122.49 01-APR-18:10 0.252675E+09 237.03 01-APR-07:10
May 0.134843E+09 122.49 01-MAY-19:10 0.260857E+09 237.03 01-MAY-06:10
June 0.130129E+09 122.49 01-JUN-19:10 0.252315E+09 237.03 01-JUN-06:10
July 0.135902E+09 122.49 01-JUL-18:10 0.261218E+09 237.03 01-JUL-07:10
August 0.134305E+09 122.49 01-AUG-19:10 0.260677E+09 237.03 01-AUG-06:10
September 0.131205E+09 122.49 01-SEP-19:10 0.252675E+09 237.03 01-SEP-06:10
October 0.135364E+09 122.49 01-OCT-18:10 0.261038E+09 237.03 01-OCT-07:10
November 0.130650E+09 122.49 01-NOV-19:10 0.252495E+09 237.03 01-NOV-06:10
December 0.135919E+09 122.49 01-DEC-20:10 0.261218E+09 237.03 01-DEC-07:10
             
Annual Sum or Average 0.159144E+10     0.307265E+10    
Minimum of Months 0.122263E+09 122.49   0.235770E+09 237.03  
Maximum of Months 0.135919E+09 122.49   0.261218E+09 237.03  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 85091918.49 76.99 01-JAN-19:10 0.255708E+09 232.19 01-JAN-08:09
February 76846309.13 76.99 01-FEB-20:10 0.230956E+09 232.19 01-FEB-07:10
March 84415649.14 76.99 01-MAR-20:10 0.255355E+09 232.19 01-MAR-07:10
April 82445007.08 76.99 01-APR-18:10 0.247516E+09 232.19 01-APR-07:10
May 84753783.81 76.99 01-MAY-19:10 0.255532E+09 232.19 01-MAY-06:10
June 81790910.76 76.99 01-JUN-19:10 0.247163E+09 232.19 01-JUN-06:10
July 85418966.65 76.99 01-JUL-18:10 0.255885E+09 232.19 01-JUL-07:10
August 84415649.14 76.99 01-AUG-19:10 0.255355E+09 232.19 01-AUG-06:10
September 82467180.11 76.99 01-SEP-19:10 0.247516E+09 232.19 01-SEP-06:10
October 85080831.98 76.99 01-OCT-18:10 0.255708E+09 232.19 01-OCT-07:10
November 82117958.92 76.99 01-NOV-19:10 0.247340E+09 232.19 01-NOV-06:10
December 85430053.17 76.99 01-DEC-20:10 0.255885E+09 232.19 01-DEC-07:10
             
Annual Sum or Average 0.100027E+10     0.300992E+10    
Minimum of Months 76846309.13 76.99   0.230956E+09 232.19  
Maximum of Months 85430053.17 76.99   0.255885E+09 232.19  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 85115186.72 77.01 01-JAN-19:10 0.255778E+09 232.26 01-JAN-08:09
February 76867322.62 77.01 01-FEB-20:10 0.231020E+09 232.26 01-FEB-07:10
March 84438732.44 77.01 01-MAR-20:10 0.255425E+09 232.26 01-MAR-07:10
April 82467551.52 77.01 01-APR-18:10 0.247584E+09 232.26 01-APR-07:10
May 84776959.58 77.01 01-MAY-19:10 0.255602E+09 232.26 01-MAY-06:10
June 81813276.33 77.01 01-JUN-19:10 0.247231E+09 232.26 01-JUN-06:10
July 85442324.32 77.01 01-JUL-18:10 0.255955E+09 232.26 01-JUL-07:10
August 84438732.44 77.01 01-AUG-19:10 0.255425E+09 232.26 01-AUG-06:10
September 82489730.61 77.01 01-SEP-19:10 0.247584E+09 232.26 01-SEP-06:10
October 85104097.18 77.01 01-OCT-18:10 0.255778E+09 232.26 01-OCT-07:10
November 82140413.93 77.01 01-NOV-19:10 0.247408E+09 232.26 01-NOV-06:10
December 85453413.86 77.01 01-DEC-20:10 0.255955E+09 232.26 01-DEC-07:10
             
Annual Sum or Average 0.100055E+10     0.301074E+10    
Minimum of Months 76867322.62 77.01   0.231020E+09 232.26  
Maximum of Months 85453413.86 77.01   0.255955E+09 232.26  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135397E+09 122.50 01-JAN-19:10 0.261068E+09 237.06 01-JAN-08:09
February 0.122277E+09 122.50 01-FEB-20:10 0.235798E+09 237.06 01-FEB-07:10
March 0.134321E+09 122.50 01-MAR-20:10 0.260708E+09 237.06 01-MAR-07:10
April 0.131185E+09 122.50 01-APR-18:10 0.252705E+09 237.06 01-APR-07:10
May 0.134859E+09 122.50 01-MAY-19:10 0.260888E+09 237.06 01-MAY-06:10
June 0.130145E+09 122.50 01-JUN-19:10 0.252344E+09 237.06 01-JUN-06:10
July 0.135918E+09 122.50 01-JUL-18:10 0.261248E+09 237.06 01-JUL-07:10
August 0.134321E+09 122.50 01-AUG-19:10 0.260708E+09 237.06 01-AUG-06:10
September 0.131221E+09 122.50 01-SEP-19:10 0.252705E+09 237.06 01-SEP-06:10
October 0.135380E+09 122.50 01-OCT-18:10 0.261068E+09 237.06 01-OCT-07:10
November 0.130665E+09 122.50 01-NOV-19:10 0.252524E+09 237.06 01-NOV-06:10
December 0.135935E+09 122.50 01-DEC-20:10 0.261248E+09 237.06 01-DEC-07:10
             
Annual Sum or Average 0.159162E+10     0.307301E+10    
Minimum of Months 0.122277E+09 122.50   0.235798E+09 237.06  
Maximum of Months 0.135935E+09 122.50   0.261248E+09 237.06  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135381E+09 122.49 01-JAN-19:10 0.261038E+09 237.03 01-JAN-08:09
February 0.122263E+09 122.49 01-FEB-20:10 0.235770E+09 237.03 01-FEB-07:10
March 0.134305E+09 122.49 01-MAR-20:10 0.260677E+09 237.03 01-MAR-07:10
April 0.131170E+09 122.49 01-APR-18:10 0.252675E+09 237.03 01-APR-07:10
May 0.134843E+09 122.49 01-MAY-19:10 0.260857E+09 237.03 01-MAY-06:10
June 0.130129E+09 122.49 01-JUN-19:10 0.252315E+09 237.03 01-JUN-06:10
July 0.135902E+09 122.49 01-JUL-18:10 0.261218E+09 237.03 01-JUL-07:10
August 0.134305E+09 122.49 01-AUG-19:10 0.260677E+09 237.03 01-AUG-06:10
September 0.131205E+09 122.49 01-SEP-19:10 0.252675E+09 237.03 01-SEP-06:10
October 0.135364E+09 122.49 01-OCT-18:10 0.261038E+09 237.03 01-OCT-07:10
November 0.130650E+09 122.49 01-NOV-19:10 0.252495E+09 237.03 01-NOV-06:10
December 0.135919E+09 122.49 01-DEC-20:10 0.261218E+09 237.03 01-DEC-07:10
             
Annual Sum or Average 0.159144E+10     0.307265E+10    
Minimum of Months 0.122263E+09 122.49   0.235770E+09 237.03  
Maximum of Months 0.135919E+09 122.49   0.261218E+09 237.03  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY []
January 0.232638E+10 2240.78 02-JAN-20:10 0.00 0.00
February 0.210051E+10 2240.78 01-FEB-20:10 0.00 0.00
March 0.233355E+10 2240.78 01-MAR-20:10 0.00 0.00
April 0.224750E+10 2240.78 03-APR-19:10 0.00 0.00
May 0.233041E+10 2240.78 01-MAY-19:10 0.00 0.00
June 0.225781E+10 2240.78 01-JUN-19:10 0.00 0.00
July 0.232011E+10 2240.78 03-JUL-19:10 0.00 0.00
August 0.233445E+10 2240.78 01-AUG-19:10 0.00 0.00
September 0.224840E+10 2240.78 01-SEP-19:10 0.00 0.00
October 0.232548E+10 2240.78 02-OCT-19:10 0.00 0.00
November 0.225602E+10 2240.78 01-NOV-19:10 0.00 0.00
December 0.232011E+10 2240.78 01-DEC-20:10 0.00 0.00
           
Annual Sum or Average 0.274007E+11     0.00 0.00
Minimum of Months 0.210051E+10 2240.78   0.00 0.00
Maximum of Months 0.233445E+10 2240.78   0.00 0.00



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135397E+09 122.50 01-JAN-19:10 0.261068E+09 237.06 01-JAN-08:09
February 0.122277E+09 122.50 01-FEB-20:10 0.235798E+09 237.06 01-FEB-07:10
March 0.134321E+09 122.50 01-MAR-20:10 0.260708E+09 237.06 01-MAR-07:10
April 0.131185E+09 122.50 01-APR-18:10 0.252705E+09 237.06 01-APR-07:10
May 0.134859E+09 122.50 01-MAY-19:10 0.260888E+09 237.06 01-MAY-06:10
June 0.130145E+09 122.50 01-JUN-19:10 0.252344E+09 237.06 01-JUN-06:10
July 0.135918E+09 122.50 01-JUL-18:10 0.261248E+09 237.06 01-JUL-07:10
August 0.134321E+09 122.50 01-AUG-19:10 0.260708E+09 237.06 01-AUG-06:10
September 0.131221E+09 122.50 01-SEP-19:10 0.252705E+09 237.06 01-SEP-06:10
October 0.135380E+09 122.50 01-OCT-18:10 0.261068E+09 237.06 01-OCT-07:10
November 0.130665E+09 122.50 01-NOV-19:10 0.252524E+09 237.06 01-NOV-06:10
December 0.135935E+09 122.50 01-DEC-20:10 0.261248E+09 237.06 01-DEC-07:10
             
Annual Sum or Average 0.159162E+10     0.307301E+10    
Minimum of Months 0.122277E+09 122.50   0.235798E+09 237.06  
Maximum of Months 0.135935E+09 122.50   0.261248E+09 237.06  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.135381E+09 122.49 01-JAN-19:10 0.261038E+09 237.03 01-JAN-08:09
February 0.122263E+09 122.49 01-FEB-20:10 0.235770E+09 237.03 01-FEB-07:10
March 0.134305E+09 122.49 01-MAR-20:10 0.260677E+09 237.03 01-MAR-07:10
April 0.131170E+09 122.49 01-APR-18:10 0.252675E+09 237.03 01-APR-07:10
May 0.134843E+09 122.49 01-MAY-19:10 0.260857E+09 237.03 01-MAY-06:10
June 0.130129E+09 122.49 01-JUN-19:10 0.252315E+09 237.03 01-JUN-06:10
July 0.135902E+09 122.49 01-JUL-18:10 0.261218E+09 237.03 01-JUL-07:10
August 0.134305E+09 122.49 01-AUG-19:10 0.260677E+09 237.03 01-AUG-06:10
September 0.131205E+09 122.49 01-SEP-19:10 0.252675E+09 237.03 01-SEP-06:10
October 0.135364E+09 122.49 01-OCT-18:10 0.261038E+09 237.03 01-OCT-07:10
November 0.130650E+09 122.49 01-NOV-19:10 0.252495E+09 237.03 01-NOV-06:10
December 0.135919E+09 122.49 01-DEC-20:10 0.261218E+09 237.03 01-DEC-07:10
             
Annual Sum or Average 0.159144E+10     0.307265E+10    
Minimum of Months 0.122263E+09 122.49   0.235770E+09 237.03  
Maximum of Months 0.135919E+09 122.49   0.261218E+09 237.03  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 85115186.72 77.01 01-JAN-19:10 0.255778E+09 232.26 01-JAN-08:09
February 76867322.62 77.01 01-FEB-20:10 0.231020E+09 232.26 01-FEB-07:10
March 84438732.44 77.01 01-MAR-20:10 0.255425E+09 232.26 01-MAR-07:10
April 82467551.52 77.01 01-APR-18:10 0.247584E+09 232.26 01-APR-07:10
May 84776959.58 77.01 01-MAY-19:10 0.255602E+09 232.26 01-MAY-06:10
June 81813276.33 77.01 01-JUN-19:10 0.247231E+09 232.26 01-JUN-06:10
July 85442324.32 77.01 01-JUL-18:10 0.255955E+09 232.26 01-JUL-07:10
August 84438732.44 77.01 01-AUG-19:10 0.255425E+09 232.26 01-AUG-06:10
September 82489730.61 77.01 01-SEP-19:10 0.247584E+09 232.26 01-SEP-06:10
October 85104097.18 77.01 01-OCT-18:10 0.255778E+09 232.26 01-OCT-07:10
November 82140413.93 77.01 01-NOV-19:10 0.247408E+09 232.26 01-NOV-06:10
December 85453413.86 77.01 01-DEC-20:10 0.255955E+09 232.26 01-DEC-07:10
             
Annual Sum or Average 0.100055E+10     0.301074E+10    
Minimum of Months 76867322.62 77.01   0.231020E+09 232.26  
Maximum of Months 85453413.86 77.01   0.255955E+09 232.26  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.318005E+10 3094.06 02-JAN-20:10 0.149358E+11 6747.90 01-JAN-07:10
February 0.279039E+10 3094.06 01-FEB-20:10 0.134904E+11 6747.90 01-FEB-07:10
March 0.299943E+10 3094.06 01-MAR-20:10 0.149358E+11 6747.90 01-MAR-07:10
April 0.270957E+10 3094.06 03-APR-19:30 0.144540E+11 6747.90 01-APR-06:10
May 0.272826E+10 2887.79 02-MAY-19:30 0.149358E+11 6747.90 01-MAY-06:10
June 0.258421E+10 2887.79 02-JUN-19:49 0.144540E+11 6747.90 01-JUN-06:10
July 0.268424E+10 2750.27 25-JUL-20:00 0.149358E+11 6747.90 01-JUL-06:10
August 0.280584E+10 3094.06 18-AUG-19:10 0.149358E+11 6747.90 01-AUG-06:10
September 0.284945E+10 3094.06 01-SEP-19:10 0.144540E+11 6747.90 01-SEP-06:10
October 0.305449E+10 3094.06 02-OCT-19:10 0.149358E+11 6747.90 01-OCT-06:10
November 0.305415E+10 3094.06 01-NOV-19:10 0.144540E+11 6747.90 01-NOV-06:10
December 0.319860E+10 3094.06 01-DEC-20:10 0.149358E+11 6747.90 01-DEC-07:10
             
Annual Sum or Average 0.346387E+11     0.175857E+12    
Minimum of Months 0.258421E+10 2750.27   0.134904E+11 6747.90  
Maximum of Months 0.319860E+10 3094.06   0.149358E+11 6747.90  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.318005E+10 3094.06 02-JAN-20:10 0.149358E+11 6747.90 01-JAN-07:10
February 0.279039E+10 3094.06 01-FEB-20:10 0.134904E+11 6747.90 01-FEB-07:10
March 0.299943E+10 3094.06 01-MAR-20:10 0.149358E+11 6747.90 01-MAR-07:10
April 0.270957E+10 3094.06 03-APR-19:30 0.144540E+11 6747.90 01-APR-06:10
May 0.272826E+10 2887.79 02-MAY-19:30 0.149358E+11 6747.90 01-MAY-06:10
June 0.258421E+10 2887.79 02-JUN-19:49 0.144540E+11 6747.90 01-JUN-06:10
July 0.268424E+10 2750.27 25-JUL-20:00 0.149358E+11 6747.90 01-JUL-06:10
August 0.280584E+10 3094.06 18-AUG-19:10 0.149358E+11 6747.90 01-AUG-06:10
September 0.284945E+10 3094.06 01-SEP-19:10 0.144540E+11 6747.90 01-SEP-06:10
October 0.305449E+10 3094.06 02-OCT-19:10 0.149358E+11 6747.90 01-OCT-06:10
November 0.305415E+10 3094.06 01-NOV-19:10 0.144540E+11 6747.90 01-NOV-06:10
December 0.319860E+10 3094.06 01-DEC-20:10 0.149358E+11 6747.90 01-DEC-07:10
             
Annual Sum or Average 0.346387E+11     0.175857E+12    
Minimum of Months 0.258421E+10 2750.27   0.134904E+11 6747.90  
Maximum of Months 0.319860E+10 3094.06   0.149358E+11 6747.90  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.113146E+10 1089.83 02-JAN-20:10 0.368383E+11 16487.34 01-JAN-07:10
February 0.102161E+10 1089.83 01-FEB-20:10 0.332733E+11 16487.34 01-FEB-07:10
March 0.113495E+10 1089.83 01-MAR-20:10 0.368383E+11 16487.34 01-MAR-07:10
April 0.109310E+10 1089.83 03-APR-19:10 0.356500E+11 16487.34 01-APR-06:10
May 0.113342E+10 1089.83 01-MAY-19:10 0.368383E+11 16487.34 01-MAY-06:10
June 0.109811E+10 1089.83 01-JUN-19:10 0.356500E+11 16487.34 01-JUN-06:10
July 0.112841E+10 1089.83 03-JUL-19:10 0.368383E+11 16487.34 01-JUL-06:10
August 0.113539E+10 1089.83 01-AUG-19:10 0.368383E+11 16487.34 01-AUG-06:10
September 0.109354E+10 1089.83 01-SEP-19:10 0.356500E+11 16487.34 01-SEP-06:10
October 0.113103E+10 1089.83 02-OCT-19:10 0.368383E+11 16487.34 01-OCT-06:10
November 0.109724E+10 1089.83 01-NOV-19:10 0.356500E+11 16487.34 01-NOV-06:10
December 0.112841E+10 1089.83 01-DEC-20:10 0.368383E+11 16487.34 01-DEC-07:10
             
Annual Sum or Average 0.133267E+11     0.433742E+12    
Minimum of Months 0.102161E+10 1089.83   0.332733E+11 16487.34  
Maximum of Months 0.113539E+10 1089.83   0.368383E+11 16487.34  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY []
January 0.246211E+10 2371.52 02-JAN-20:10 0.00 0.00
February 0.222306E+10 2371.52 01-FEB-20:10 0.00 0.00
March 0.246970E+10 2371.52 01-MAR-20:10 0.00 0.00
April 0.237864E+10 2371.52 03-APR-19:10 0.00 0.00
May 0.246638E+10 2371.52 01-MAY-19:10 0.00 0.00
June 0.238954E+10 2371.52 01-JUN-19:10 0.00 0.00
July 0.245547E+10 2371.52 03-JUL-19:10 0.00 0.00
August 0.247065E+10 2371.52 01-AUG-19:10 0.00 0.00
September 0.237958E+10 2371.52 01-SEP-19:10 0.00 0.00
October 0.246116E+10 2371.52 02-OCT-19:10 0.00 0.00
November 0.238765E+10 2371.52 01-NOV-19:10 0.00 0.00
December 0.245547E+10 2371.52 01-DEC-20:10 0.00 0.00
           
Annual Sum or Average 0.289994E+11     0.00 0.00
Minimum of Months 0.222306E+10 2371.52   0.00 0.00
Maximum of Months 0.247065E+10 2371.52   0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.195762E+11 0.147273E+11 0.127587E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.176991E+11 0.132974E+11 0.115208E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.196682E+11 0.147727E+11 0.127855E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.189781E+11 0.142280E+11 0.123314E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.196176E+11 0.147528E+11 0.127741E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.190195E+11 0.142932E+11 0.123716E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.195762E+11 0.146876E+11 0.127338E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.196590E+11 0.147784E+11 0.127894E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.189689E+11 0.142337E+11 0.123352E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.195854E+11 0.147216E+11 0.127549E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.189367E+11 0.142819E+11 0.123659E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.195762E+11 0.146876E+11 0.127338E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.230861E+12 0.173462E+12 0.150255E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.176991E+11 0.132974E+11 0.115208E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.196682E+11 0.147784E+11 0.127894E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.199054E+10 0.731324E+09 0.864900E+09 0.00 0.00 0.00 0.00 0.00 0.137686E+10
February 0.179968E+10 0.660319E+09 0.780982E+09 0.00 0.00 0.00 0.00 0.00 0.117853E+10
March 0.199990E+10 0.733578E+09 0.866718E+09 0.00 0.00 0.00 0.00 0.00 0.110644E+10
April 0.192973E+10 0.706528E+09 0.835931E+09 0.00 0.00 0.00 0.00 0.00 0.680452E+09
May 0.199475E+10 0.732592E+09 0.865939E+09 0.00 0.00 0.00 0.00 0.00 0.362881E+09
June 0.193394E+10 0.709769E+09 0.838659E+09 0.00 0.00 0.00 0.00 2576823.23 0.190152E+09
July 0.199054E+10 0.729351E+09 0.863211E+09 0.00 0.00 0.00 0.00 5677238.43 0.168721E+09
August 0.199896E+10 0.733860E+09 0.866978E+09 0.00 0.00 0.00 0.00 707557.58 0.247098E+09
September 0.192879E+10 0.706810E+09 0.836191E+09 0.00 0.00 0.00 0.00 0.00 0.465645E+09
October 0.199148E+10 0.731042E+09 0.864640E+09 0.00 0.00 0.00 0.00 0.00 0.825362E+09
November 0.192552E+10 0.709205E+09 0.838269E+09 0.00 0.00 0.00 0.00 0.00 0.133942E+10
December 0.199054E+10 0.729351E+09 0.863211E+09 0.00 0.00 0.00 0.00 0.00 0.144970E+10
                   
Annual Sum or Average 0.234744E+11 0.861373E+10 0.101856E+11 0.00 0.00 0.00 0.00 8961619.24 0.939126E+10
Minimum of Months 0.179968E+10 0.660319E+09 0.780982E+09 0.00 0.00 0.00 0.00 0.00 0.168721E+09
Maximum of Months 0.199990E+10 0.733860E+09 0.866978E+09 0.00 0.00 0.00 0.00 5677238.43 0.144970E+10



Table of Contents

Report: SpaceGainsMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.230505E+10 0.846876E+09 0.100156E+10 0.00 0.00 0.00 0.00 0.00 0.532911E+09
February 0.208403E+10 0.764651E+09 0.904380E+09 0.00 0.00 0.00 0.00 0.00 0.456188E+09
March 0.231589E+10 0.849486E+09 0.100366E+10 0.00 0.00 0.00 0.00 0.00 0.428973E+09
April 0.223463E+10 0.818162E+09 0.968011E+09 0.00 0.00 0.00 0.00 0.00 0.272412E+09
May 0.230993E+10 0.848344E+09 0.100276E+10 0.00 0.00 0.00 0.00 0.00 0.156772E+09
June 0.223950E+10 0.821915E+09 0.971170E+09 0.00 0.00 0.00 0.00 906481.50 89905922.70
July 0.230505E+10 0.844592E+09 0.999601E+09 0.00 0.00 0.00 0.00 2092894.52 82642372.42
August 0.231480E+10 0.849812E+09 0.100396E+10 0.00 0.00 0.00 0.00 252724.14 0.113594E+09
September 0.223354E+10 0.818489E+09 0.968312E+09 0.00 0.00 0.00 0.00 0.00 0.195536E+09
October 0.230614E+10 0.846549E+09 0.100126E+10 0.00 0.00 0.00 0.00 0.00 0.325964E+09
November 0.222975E+10 0.821262E+09 0.970719E+09 0.00 0.00 0.00 0.00 0.00 0.517808E+09
December 0.230505E+10 0.844592E+09 0.999601E+09 0.00 0.00 0.00 0.00 0.00 0.559931E+09
                   
Annual Sum or Average 0.271834E+11 0.997473E+10 0.117950E+11 0.00 0.00 0.00 0.00 3252100.17 0.373263E+10
Minimum of Months 0.208403E+10 0.764651E+09 0.904380E+09 0.00 0.00 0.00 0.00 0.00 82642372.42
Maximum of Months 0.231589E+10 0.849812E+09 0.100396E+10 0.00 0.00 0.00 0.00 2092894.52 0.559931E+09



Table of Contents

Report: SpaceGainsMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.487480E+09 0.141236E+10 0.105898E+10 0.00 0.00 0.00 0.00 0.00 0.125819E+10
February 0.440737E+09 0.127524E+10 0.956227E+09 0.00 0.00 0.00 0.00 0.00 0.107485E+10
March 0.489771E+09 0.141672E+10 0.106120E+10 0.00 0.00 0.00 0.00 0.00 0.100285E+10
April 0.472586E+09 0.136448E+10 0.102351E+10 0.00 0.00 0.00 0.00 0.00 0.613472E+09
May 0.488511E+09 0.141481E+10 0.106025E+10 0.00 0.00 0.00 0.00 0.00 0.353130E+09
June 0.473617E+09 0.137074E+10 0.102685E+10 0.00 0.00 0.00 0.00 2307074.77 0.208305E+09
July 0.487480E+09 0.140855E+10 0.105691E+10 0.00 0.00 0.00 0.00 5230743.41 0.194070E+09
August 0.489542E+09 0.141726E+10 0.106152E+10 0.00 0.00 0.00 0.00 957657.52 0.261730E+09
September 0.472357E+09 0.136502E+10 0.102382E+10 0.00 0.00 0.00 0.00 0.00 0.442871E+09
October 0.487709E+09 0.141182E+10 0.105866E+10 0.00 0.00 0.00 0.00 0.00 0.754843E+09
November 0.471555E+09 0.136965E+10 0.102637E+10 0.00 0.00 0.00 0.00 0.00 0.122189E+10
December 0.487480E+09 0.140855E+10 0.105691E+10 0.00 0.00 0.00 0.00 0.00 0.132264E+10
                   
Annual Sum or Average 0.574883E+10 0.166352E+11 0.124712E+11 0.00 0.00 0.00 0.00 8495475.70 0.870884E+10
Minimum of Months 0.440737E+09 0.127524E+10 0.956227E+09 0.00 0.00 0.00 0.00 0.00 0.194070E+09
Maximum of Months 0.489771E+09 0.141726E+10 0.106152E+10 0.00 0.00 0.00 0.00 5230743.41 0.132264E+10



Table of Contents

Report: SpaceGainsMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.374985E+09 0.236418E+09 0.305485E+09 0.00 0.00 0.00 0.00 0.00 0.725836E+09
February 0.339028E+09 0.213464E+09 0.275845E+09 0.00 0.00 0.00 0.00 0.00 0.620115E+09
March 0.376747E+09 0.237147E+09 0.306128E+09 0.00 0.00 0.00 0.00 0.00 0.578357E+09
April 0.363528E+09 0.228402E+09 0.295253E+09 0.00 0.00 0.00 0.00 0.00 0.351101E+09
May 0.375778E+09 0.236828E+09 0.305852E+09 0.00 0.00 0.00 0.00 0.00 0.199155E+09
June 0.364321E+09 0.229450E+09 0.296217E+09 0.00 0.00 0.00 0.00 1453126.27 0.116654E+09
July 0.374985E+09 0.235780E+09 0.304889E+09 0.00 0.00 0.00 0.00 3265395.93 0.108557E+09
August 0.376571E+09 0.237238E+09 0.306219E+09 0.00 0.00 0.00 0.00 626582.80 0.146566E+09
September 0.363352E+09 0.228493E+09 0.295345E+09 0.00 0.00 0.00 0.00 0.00 0.250599E+09
October 0.375161E+09 0.236327E+09 0.305393E+09 0.00 0.00 0.00 0.00 0.00 0.433775E+09
November 0.362735E+09 0.229268E+09 0.296079E+09 0.00 0.00 0.00 0.00 0.00 0.704963E+09
December 0.374985E+09 0.235780E+09 0.304889E+09 0.00 0.00 0.00 0.00 0.00 0.763091E+09
                   
Annual Sum or Average 0.442217E+10 0.278459E+10 0.359760E+10 0.00 0.00 0.00 0.00 5345105.00 0.499877E+10
Minimum of Months 0.339028E+09 0.213464E+09 0.275845E+09 0.00 0.00 0.00 0.00 0.00 0.108557E+09
Maximum of Months 0.376747E+09 0.237238E+09 0.306219E+09 0.00 0.00 0.00 0.00 3265395.93 0.763091E+09



Table of Contents

Report: SpaceGainsMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.154405E+10 0.370859E+09 0.576866E+10 0.501157E+11 0.00 0.00 0.00 0.00 0.178493E+10
February 0.139600E+10 0.334852E+09 0.520895E+10 0.452532E+11 0.00 0.00 0.00 0.00 0.153356E+10
March 0.155131E+10 0.372002E+09 0.578079E+10 0.502211E+11 0.00 0.00 0.00 0.00 0.145241E+10
April 0.149688E+10 0.358285E+09 0.557545E+10 0.484372E+11 0.00 0.00 0.00 0.00 0.909991E+09
May 0.154732E+10 0.371502E+09 0.577559E+10 0.501759E+11 0.00 0.00 0.00 0.00 0.516307E+09
June 0.150015E+10 0.359929E+09 0.559364E+10 0.485952E+11 0.00 0.00 0.00 3278543.11 0.287138E+09
July 0.154405E+10 0.369859E+09 0.575740E+10 0.500179E+11 0.00 0.00 0.00 8031216.71 0.264897E+09
August 0.155059E+10 0.372145E+09 0.578252E+10 0.502361E+11 0.00 0.00 0.00 1157494.38 0.368523E+09
September 0.149615E+10 0.358428E+09 0.557718E+10 0.484522E+11 0.00 0.00 0.00 0.00 0.659506E+09
October 0.154478E+10 0.370717E+09 0.576693E+10 0.501006E+11 0.00 0.00 0.00 0.00 0.111328E+10
November 0.149361E+10 0.359643E+09 0.559104E+10 0.485726E+11 0.00 0.00 0.00 0.00 0.173904E+10
December 0.154405E+10 0.369859E+09 0.575740E+10 0.500179E+11 0.00 0.00 0.00 0.00 0.187461E+10
                   
Annual Sum or Average 0.182090E+11 0.436808E+10 0.679355E+11 0.590196E+12 0.00 0.00 0.00 12467254.20 0.125042E+11
Minimum of Months 0.139600E+10 0.334852E+09 0.520895E+10 0.452532E+11 0.00 0.00 0.00 0.00 0.264897E+09
Maximum of Months 0.155131E+10 0.372145E+09 0.578252E+10 0.502361E+11 0.00 0.00 0.00 8031216.71 0.187461E+10



Table of Contents

Report: SpaceGainsMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.261570E+11 0.175838E+10 0.121771E+10 0.00 0.00 0.00 0.00 0.00 0.304584E+10
February 0.236489E+11 0.150663E+10 0.109956E+10 0.00 0.00 0.00 0.00 0.00 0.260745E+10
March 0.262800E+11 0.156853E+10 0.122027E+10 0.00 0.00 0.00 0.00 0.00 0.246369E+10
April 0.253579E+11 0.133560E+10 0.117692E+10 0.00 0.00 0.00 0.00 0.00 0.155420E+10
May 0.262123E+11 0.131501E+10 0.121917E+10 0.00 0.00 0.00 0.00 0.00 0.875291E+09
June 0.254132E+11 0.121172E+10 0.118076E+10 0.00 0.00 0.00 0.00 4500011.57 0.487902E+09
July 0.261570E+11 0.127133E+10 0.121533E+10 0.00 0.00 0.00 0.00 10437853.17 0.441286E+09
August 0.262677E+11 0.138099E+10 0.122063E+10 0.00 0.00 0.00 0.00 1124098.66 0.616823E+09
September 0.253456E+11 0.146907E+10 0.117729E+10 0.00 0.00 0.00 0.00 0.00 0.108597E+10
October 0.261693E+11 0.163798E+10 0.121734E+10 0.00 0.00 0.00 0.00 0.00 0.184446E+10
November 0.253025E+11 0.166694E+10 0.118021E+10 0.00 0.00 0.00 0.00 0.00 0.296121E+10
December 0.261570E+11 0.179438E+10 0.121533E+10 0.00 0.00 0.00 0.00 0.00 0.320467E+10
                   
Annual Sum or Average 0.308468E+12 0.179166E+11 0.143405E+11 0.00 0.00 0.00 0.00 16061963.40 0.211888E+11
Minimum of Months 0.236489E+11 0.121172E+10 0.109956E+10 0.00 0.00 0.00 0.00 0.00 0.441286E+09
Maximum of Months 0.262800E+11 0.179438E+10 0.122063E+10 0.00 0.00 0.00 0.00 10437853.17 0.320467E+10



Table of Contents

Report: SpaceGainsMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.776503E+11 0.105901E+11 0.126520E+11 0.00 0.00 0.00 0.00 0.00 0.875481E+10
February 0.702046E+11 0.947482E+10 0.114244E+11 0.00 0.00 0.00 0.00 0.00 0.750967E+10
March 0.780153E+11 0.104188E+11 0.126786E+11 0.00 0.00 0.00 0.00 0.00 0.711520E+10
April 0.752779E+11 0.986187E+10 0.122282E+11 0.00 0.00 0.00 0.00 0.00 0.454960E+10
May 0.778146E+11 0.101589E+11 0.126672E+11 0.00 0.00 0.00 0.00 0.00 0.263617E+10
June 0.754422E+11 0.977822E+10 0.122682E+11 0.00 0.00 0.00 0.00 12373757.54 0.151354E+10
July 0.776503E+11 0.100752E+11 0.126273E+11 0.00 0.00 0.00 0.00 28205878.96 0.139481E+10
August 0.779788E+11 0.102430E+11 0.126824E+11 0.00 0.00 0.00 0.00 2895878.86 0.191552E+10
September 0.752414E+11 0.999925E+10 0.122320E+11 0.00 0.00 0.00 0.00 0.00 0.328134E+10
October 0.776868E+11 0.104600E+11 0.126482E+11 0.00 0.00 0.00 0.00 0.00 0.542055E+10
November 0.751137E+11 0.102306E+11 0.122624E+11 0.00 0.00 0.00 0.00 0.00 0.851126E+10
December 0.776503E+11 0.106063E+11 0.126273E+11 0.00 0.00 0.00 0.00 0.00 0.918483E+10
                   
Annual Sum or Average 0.915726E+12 0.121897E+12 0.148998E+12 0.00 0.00 0.00 0.00 43475515.36 0.617873E+11
Minimum of Months 0.702046E+11 0.947482E+10 0.114244E+11 0.00 0.00 0.00 0.00 0.00 0.139481E+10
Maximum of Months 0.780153E+11 0.106063E+11 0.126824E+11 0.00 0.00 0.00 0.00 28205878.96 0.918483E+10



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135397E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.790492E+09
February 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 0.675214E+09
March 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 0.00 0.632611E+09
April 0.293479E+09 0.131185E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.389249E+09
May 0.303504E+09 0.134859E+09 0.260888E+09 0.00 0.00 0.00 0.00 31901.28 0.208405E+09
June 0.293842E+09 0.130145E+09 0.252344E+09 0.00 0.00 0.00 0.00 3220160.08 0.107325E+09
July 0.303141E+09 0.135918E+09 0.261248E+09 0.00 0.00 0.00 0.00 6541675.56 97116135.12
August 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 1666284.87 0.141888E+09
September 0.293479E+09 0.131221E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.268365E+09
October 0.303322E+09 0.135380E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.471422E+09
November 0.293661E+09 0.130665E+09 0.252524E+09 0.00 0.00 0.00 0.00 0.00 0.767718E+09
December 0.303141E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 0.00 0.831370E+09
                   
Annual Sum or Average 0.357224E+10 0.159162E+10 0.307301E+10 0.00 0.00 0.00 0.00 11460021.79 0.538117E+10
Minimum of Months 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 97116135.12
Maximum of Months 0.303685E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 6541675.56 0.831370E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135381E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.790409E+09
February 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 0.674860E+09
March 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 0.00 0.628852E+09
April 0.293479E+09 0.131170E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.382687E+09
May 0.303504E+09 0.134843E+09 0.260857E+09 0.00 0.00 0.00 0.00 32023.95 0.206022E+09
June 0.293842E+09 0.130129E+09 0.252315E+09 0.00 0.00 0.00 0.00 3222672.18 0.106937E+09
July 0.303141E+09 0.135902E+09 0.261218E+09 0.00 0.00 0.00 0.00 6576796.54 96590642.59
August 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 1683918.90 0.139753E+09
September 0.293479E+09 0.131205E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.263802E+09
October 0.303322E+09 0.135364E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.469174E+09
November 0.293661E+09 0.130650E+09 0.252495E+09 0.00 0.00 0.00 0.00 0.00 0.767630E+09
December 0.303141E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 0.00 0.831297E+09
                   
Annual Sum or Average 0.357224E+10 0.159144E+10 0.307265E+10 0.00 0.00 0.00 0.00 11515411.57 0.535801E+10
Minimum of Months 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 96590642.59
Maximum of Months 0.303685E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 6576796.54 0.831297E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 85091918.49 0.255708E+09 0.00 0.00 0.00 0.00 0.00 0.211492E+09
February 0.00 76846309.13 0.230956E+09 0.00 0.00 0.00 0.00 0.00 0.180998E+09
March 0.00 84415649.14 0.255355E+09 0.00 0.00 0.00 0.00 0.00 0.172807E+09
April 0.00 82445007.08 0.247516E+09 0.00 0.00 0.00 0.00 0.00 0.114171E+09
May 0.00 84753783.81 0.255532E+09 0.00 0.00 0.00 0.00 0.00 66041816.47
June 0.00 81790910.76 0.247163E+09 0.00 0.00 0.00 0.00 424111.63 37479404.34
July 0.00 85418966.65 0.255885E+09 0.00 0.00 0.00 0.00 967174.73 34464194.11
August 0.00 84415649.14 0.255355E+09 0.00 0.00 0.00 0.00 138657.38 47641902.42
September 0.00 82467180.11 0.247516E+09 0.00 0.00 0.00 0.00 0.00 80440370.21
October 0.00 85080831.98 0.255708E+09 0.00 0.00 0.00 0.00 0.00 0.128179E+09
November 0.00 82117958.92 0.247340E+09 0.00 0.00 0.00 0.00 0.00 0.205472E+09
December 0.00 85430053.17 0.255885E+09 0.00 0.00 0.00 0.00 0.00 0.222793E+09
                   
Annual Sum or Average 0.00 0.100027E+10 0.300992E+10 0.00 0.00 0.00 0.00 1529943.75 0.150198E+10
Minimum of Months 0.00 76846309.13 0.230956E+09 0.00 0.00 0.00 0.00 0.00 34464194.11
Maximum of Months 0.00 85430053.17 0.255885E+09 0.00 0.00 0.00 0.00 967174.73 0.222793E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 85115186.72 0.255778E+09 0.00 0.00 0.00 0.00 0.00 0.220907E+09
February 0.273974E+09 76867322.62 0.231020E+09 0.00 0.00 0.00 0.00 0.00 0.188747E+09
March 0.303685E+09 84438732.44 0.255425E+09 0.00 0.00 0.00 0.00 0.00 0.176309E+09
April 0.293479E+09 82467551.52 0.247584E+09 0.00 0.00 0.00 0.00 0.00 0.106850E+09
May 0.303504E+09 84776959.58 0.255602E+09 0.00 0.00 0.00 0.00 9041.87 56745488.49
June 0.293842E+09 81813276.33 0.247231E+09 0.00 0.00 0.00 0.00 967930.23 29047472.99
July 0.303141E+09 85442324.32 0.255955E+09 0.00 0.00 0.00 0.00 2052694.60 26300634.50
August 0.303685E+09 84438732.44 0.255425E+09 0.00 0.00 0.00 0.00 565884.68 38290513.45
September 0.293479E+09 82489730.61 0.247584E+09 0.00 0.00 0.00 0.00 0.00 74208276.80
October 0.303322E+09 85104097.18 0.255778E+09 0.00 0.00 0.00 0.00 0.00 0.132084E+09
November 0.293661E+09 82140413.93 0.247408E+09 0.00 0.00 0.00 0.00 0.00 0.214542E+09
December 0.303141E+09 85453413.86 0.255955E+09 0.00 0.00 0.00 0.00 0.00 0.232291E+09
                   
Annual Sum or Average 0.357224E+10 0.100055E+10 0.301074E+10 0.00 0.00 0.00 0.00 3595551.39 0.149632E+10
Minimum of Months 0.273974E+09 76867322.62 0.231020E+09 0.00 0.00 0.00 0.00 0.00 26300634.50
Maximum of Months 0.303685E+09 85453413.86 0.255955E+09 0.00 0.00 0.00 0.00 2052694.60 0.232291E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135397E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.790506E+09
February 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 0.675717E+09
March 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 0.00 0.637495E+09
April 0.293479E+09 0.131185E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.391921E+09
May 0.303504E+09 0.134859E+09 0.260888E+09 0.00 0.00 0.00 0.00 32043.89 0.210031E+09
June 0.293842E+09 0.130145E+09 0.252344E+09 0.00 0.00 0.00 0.00 3236733.29 0.108142E+09
July 0.303141E+09 0.135918E+09 0.261248E+09 0.00 0.00 0.00 0.00 6563093.99 97992239.10
August 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 1682359.91 0.143281E+09
September 0.293479E+09 0.131221E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.271070E+09
October 0.303322E+09 0.135380E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.473419E+09
November 0.293661E+09 0.130665E+09 0.252524E+09 0.00 0.00 0.00 0.00 0.00 0.767736E+09
December 0.303141E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 0.00 0.831368E+09
                   
Annual Sum or Average 0.357224E+10 0.159162E+10 0.307301E+10 0.00 0.00 0.00 0.00 11514231.08 0.539868E+10
Minimum of Months 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 97992239.10
Maximum of Months 0.303685E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 6563093.99 0.831368E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135381E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.790416E+09
February 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 0.674961E+09
March 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 0.00 0.631482E+09
April 0.293479E+09 0.131170E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.387009E+09
May 0.303504E+09 0.134843E+09 0.260857E+09 0.00 0.00 0.00 0.00 32177.66 0.209517E+09
June 0.293842E+09 0.130129E+09 0.252315E+09 0.00 0.00 0.00 0.00 3245564.20 0.108081E+09
July 0.303141E+09 0.135902E+09 0.261218E+09 0.00 0.00 0.00 0.00 6591689.99 97927950.23
August 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 1706056.07 0.142615E+09
September 0.293479E+09 0.131205E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.267966E+09
October 0.303322E+09 0.135364E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.470670E+09
November 0.293661E+09 0.130650E+09 0.252495E+09 0.00 0.00 0.00 0.00 0.00 0.767636E+09
December 0.303141E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 0.00 0.831295E+09
                   
Annual Sum or Average 0.357224E+10 0.159144E+10 0.307265E+10 0.00 0.00 0.00 0.00 11575487.92 0.537958E+10
Minimum of Months 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 97927950.23
Maximum of Months 0.303685E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 6591689.99 0.831295E+09



Table of Contents

Report: SpaceGainsMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.385223E+10 0.232638E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.969015E+09
February 0.348285E+10 0.210051E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.827894E+09
March 0.387034E+10 0.233355E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.772622E+09
April 0.373454E+10 0.224750E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.479027E+09
May 0.386038E+10 0.233041E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.279886E+09
June 0.374269E+10 0.225781E+10 0.00 0.00 0.00 0.00 0.00 1402240.95 0.165089E+09
July 0.385223E+10 0.232011E+10 0.00 0.00 0.00 0.00 0.00 3328091.18 0.150573E+09
August 0.386853E+10 0.233445E+10 0.00 0.00 0.00 0.00 0.00 560116.26 0.201086E+09
September 0.373273E+10 0.224840E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.337044E+09
October 0.385404E+10 0.232548E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.579112E+09
November 0.372639E+10 0.225602E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.941113E+09
December 0.385223E+10 0.232011E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.101867E+10
                   
Annual Sum or Average 0.454292E+11 0.274007E+11 0.00 0.00 0.00 0.00 0.00 5290448.38 0.672113E+10
Minimum of Months 0.348285E+10 0.210051E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.150573E+09
Maximum of Months 0.387034E+10 0.233445E+10 0.00 0.00 0.00 0.00 0.00 3328091.18 0.101867E+10



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135397E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.791823E+09
February 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 0.676171E+09
March 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 0.00 0.632045E+09
April 0.293479E+09 0.131185E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.388677E+09
May 0.303504E+09 0.134859E+09 0.260888E+09 0.00 0.00 0.00 0.00 29060.60 0.208773E+09
June 0.293842E+09 0.130145E+09 0.252344E+09 0.00 0.00 0.00 0.00 3123287.97 0.107923E+09
July 0.303141E+09 0.135918E+09 0.261248E+09 0.00 0.00 0.00 0.00 6364809.05 97671436.13
August 0.303685E+09 0.134321E+09 0.260708E+09 0.00 0.00 0.00 0.00 1605406.34 0.142216E+09
September 0.293479E+09 0.131221E+09 0.252705E+09 0.00 0.00 0.00 0.00 0.00 0.267564E+09
October 0.303322E+09 0.135380E+09 0.261068E+09 0.00 0.00 0.00 0.00 0.00 0.471332E+09
November 0.293661E+09 0.130665E+09 0.252524E+09 0.00 0.00 0.00 0.00 0.00 0.769009E+09
December 0.303141E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 0.00 0.832740E+09
                   
Annual Sum or Average 0.357224E+10 0.159162E+10 0.307301E+10 0.00 0.00 0.00 0.00 11122563.97 0.538594E+10
Minimum of Months 0.273974E+09 0.122277E+09 0.235798E+09 0.00 0.00 0.00 0.00 0.00 97671436.13
Maximum of Months 0.303685E+09 0.135935E+09 0.261248E+09 0.00 0.00 0.00 0.00 6364809.05 0.832740E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 0.135381E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.791750E+09
February 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 0.676038E+09
March 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 0.00 0.629802E+09
April 0.293479E+09 0.131170E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.382204E+09
May 0.303504E+09 0.134843E+09 0.260857E+09 0.00 0.00 0.00 0.00 29177.24 0.205934E+09
June 0.293842E+09 0.130129E+09 0.252315E+09 0.00 0.00 0.00 0.00 3128053.25 0.107466E+09
July 0.303141E+09 0.135902E+09 0.261218E+09 0.00 0.00 0.00 0.00 6400671.80 97092992.39
August 0.303685E+09 0.134305E+09 0.260677E+09 0.00 0.00 0.00 0.00 1623294.36 0.139758E+09
September 0.293479E+09 0.131205E+09 0.252675E+09 0.00 0.00 0.00 0.00 0.00 0.262830E+09
October 0.303322E+09 0.135364E+09 0.261038E+09 0.00 0.00 0.00 0.00 0.00 0.469610E+09
November 0.293661E+09 0.130650E+09 0.252495E+09 0.00 0.00 0.00 0.00 0.00 0.768931E+09
December 0.303141E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 0.00 0.832671E+09
                   
Annual Sum or Average 0.357224E+10 0.159144E+10 0.307265E+10 0.00 0.00 0.00 0.00 11181196.65 0.536409E+10
Minimum of Months 0.273974E+09 0.122263E+09 0.235770E+09 0.00 0.00 0.00 0.00 0.00 97092992.39
Maximum of Months 0.303685E+09 0.135919E+09 0.261218E+09 0.00 0.00 0.00 0.00 6400671.80 0.832671E+09



Table of Contents

Report: SpaceGainsMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.303322E+09 85115186.72 0.255778E+09 0.00 0.00 0.00 0.00 0.00 0.405335E+09
February 0.273974E+09 76867322.62 0.231020E+09 0.00 0.00 0.00 0.00 0.00 0.348793E+09
March 0.303685E+09 84438732.44 0.255425E+09 0.00 0.00 0.00 0.00 0.00 0.329134E+09
April 0.293479E+09 82467551.52 0.247584E+09 0.00 0.00 0.00 0.00 0.00 0.201666E+09
May 0.303504E+09 84776959.58 0.255602E+09 0.00 0.00 0.00 0.00 14887.05 0.107459E+09
June 0.293842E+09 81813276.33 0.247231E+09 0.00 0.00 0.00 0.00 1606227.67 55312702.81
July 0.303141E+09 85442324.32 0.255955E+09 0.00 0.00 0.00 0.00 3264556.87 50126296.08
August 0.303685E+09 84438732.44 0.255425E+09 0.00 0.00 0.00 0.00 819027.07 73393865.93
September 0.293479E+09 82489730.61 0.247584E+09 0.00 0.00 0.00 0.00 0.00 0.139695E+09
October 0.303322E+09 85104097.18 0.255778E+09 0.00 0.00 0.00 0.00 0.00 0.244786E+09
November 0.293661E+09 82140413.93 0.247408E+09 0.00 0.00 0.00 0.00 0.00 0.394124E+09
December 0.303141E+09 85453413.86 0.255955E+09 0.00 0.00 0.00 0.00 0.00 0.426108E+09
                   
Annual Sum or Average 0.357224E+10 0.100055E+10 0.301074E+10 0.00 0.00 0.00 0.00 5704698.65 0.277593E+10
Minimum of Months 0.273974E+09 76867322.62 0.231020E+09 0.00 0.00 0.00 0.00 0.00 50126296.08
Maximum of Months 0.303685E+09 85453413.86 0.255955E+09 0.00 0.00 0.00 0.00 3264556.87 0.426108E+09



Table of Contents

Report: SpaceGainsMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.459349E+11 0.318005E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.203617E+10
February 0.415303E+11 0.279039E+10 0.134904E+11 0.00 0.00 0.00 0.00 0.00 0.174994E+10
March 0.461508E+11 0.299943E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.166918E+10
April 0.445315E+11 0.270957E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.106295E+10
May 0.460320E+11 0.272826E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.620013E+09
June 0.446286E+11 0.258421E+10 0.144540E+11 0.00 0.00 0.00 0.00 2314374.42 0.360048E+09
July 0.459349E+11 0.268424E+10 0.149358E+11 0.00 0.00 0.00 0.00 5472115.11 0.333182E+09
August 0.461292E+11 0.280584E+10 0.149358E+11 0.00 0.00 0.00 0.00 548870.39 0.452561E+09
September 0.445099E+11 0.284945E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.775805E+09
October 0.459565E+11 0.305449E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.128764E+10
November 0.444343E+11 0.305415E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.197979E+10
December 0.459349E+11 0.319860E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.213059E+10
                   
Annual Sum or Average 0.541708E+12 0.346387E+11 0.175857E+12 0.00 0.00 0.00 0.00 8335359.92 0.144579E+11
Minimum of Months 0.415303E+11 0.258421E+10 0.134904E+11 0.00 0.00 0.00 0.00 0.00 0.333182E+09
Maximum of Months 0.461508E+11 0.319860E+10 0.149358E+11 0.00 0.00 0.00 0.00 5472115.11 0.213059E+10



Table of Contents

Report: SpaceGainsMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.459349E+11 0.318005E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.204981E+10
February 0.415303E+11 0.279039E+10 0.134904E+11 0.00 0.00 0.00 0.00 0.00 0.176225E+10
March 0.461508E+11 0.299943E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.168111E+10
April 0.445315E+11 0.270957E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.106927E+10
May 0.460320E+11 0.272826E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.621882E+09
June 0.446286E+11 0.258421E+10 0.144540E+11 0.00 0.00 0.00 0.00 2314307.68 0.360379E+09
July 0.459349E+11 0.268424E+10 0.149358E+11 0.00 0.00 0.00 0.00 5471971.71 0.333563E+09
August 0.461292E+11 0.280584E+10 0.149358E+11 0.00 0.00 0.00 0.00 548836.16 0.454001E+09
September 0.445099E+11 0.284945E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.780602E+09
October 0.459565E+11 0.305449E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.129779E+10
November 0.444343E+11 0.305415E+10 0.144540E+11 0.00 0.00 0.00 0.00 0.00 0.199402E+10
December 0.459349E+11 0.319860E+10 0.149358E+11 0.00 0.00 0.00 0.00 0.00 0.214410E+10
                   
Annual Sum or Average 0.541708E+12 0.346387E+11 0.175857E+12 0.00 0.00 0.00 0.00 8335115.55 0.145488E+11
Minimum of Months 0.415303E+11 0.258421E+10 0.134904E+11 0.00 0.00 0.00 0.00 0.00 0.333563E+09
Maximum of Months 0.461508E+11 0.319860E+10 0.149358E+11 0.00 0.00 0.00 0.00 5471971.71 0.214410E+10



Table of Contents

Report: SpaceGainsMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.408770E+10 0.113146E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 0.00 0.185712E+10
February 0.369574E+10 0.102161E+10 0.301256E+11 0.275852E+11 0.00 0.00 0.00 0.00 0.159798E+10
March 0.410691E+10 0.113495E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 0.00 0.151298E+10
April 0.396281E+10 0.109310E+10 0.322775E+11 0.295556E+11 0.00 0.00 0.00 0.00 0.958316E+09
May 0.409635E+10 0.113342E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 0.00 0.557555E+09
June 0.397146E+10 0.109811E+10 0.322775E+11 0.295556E+11 0.00 0.00 0.00 2082962.20 0.321536E+09
July 0.408770E+10 0.112841E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 4921203.98 0.297367E+09
August 0.410499E+10 0.113539E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 496509.00 0.406304E+09
September 0.396089E+10 0.109354E+10 0.322775E+11 0.295556E+11 0.00 0.00 0.00 0.00 0.702243E+09
October 0.408962E+10 0.113103E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 0.00 0.116693E+10
November 0.395417E+10 0.109724E+10 0.322775E+11 0.295556E+11 0.00 0.00 0.00 0.00 0.181016E+10
December 0.408770E+10 0.112841E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 0.00 0.195050E+10
                   
Annual Sum or Average 0.482060E+11 0.133267E+11 0.392709E+12 0.359593E+12 0.00 0.00 0.00 7500675.18 0.131390E+11
Minimum of Months 0.369574E+10 0.102161E+10 0.301256E+11 0.275852E+11 0.00 0.00 0.00 0.00 0.297367E+09
Maximum of Months 0.410691E+10 0.113539E+10 0.333534E+11 0.305408E+11 0.00 0.00 0.00 4921203.98 0.195050E+10



Table of Contents

Report: SpaceGainsMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.407704E+10 0.246211E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.171754E+10
February 0.368610E+10 0.222306E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.146753E+10
March 0.409620E+10 0.246970E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.136999E+10
April 0.395248E+10 0.237864E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.844060E+09
May 0.408566E+10 0.246638E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.486714E+09
June 0.396110E+10 0.238954E+10 0.00 0.00 0.00 0.00 0.00 2030915.43 0.290712E+09
July 0.407704E+10 0.245547E+10 0.00 0.00 0.00 0.00 0.00 4858374.04 0.265551E+09
August 0.409429E+10 0.247065E+10 0.00 0.00 0.00 0.00 0.00 625174.04 0.351915E+09
September 0.395056E+10 0.237958E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.590767E+09
October 0.407896E+10 0.246116E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.102721E+10
November 0.394385E+10 0.238765E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.166807E+10
December 0.407704E+10 0.245547E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.180543E+10
                   
Annual Sum or Average 0.480803E+11 0.289994E+11 0.00 0.00 0.00 0.00 0.00 7514463.50 0.118855E+11
Minimum of Months 0.368610E+10 0.222306E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.265551E+09
Maximum of Months 0.409620E+10 0.247065E+10 0.00 0.00 0.00 0.00 0.00 4858374.04 0.180543E+10



Table of Contents

Report: PeakSpaceGainsMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 11501.89 02-JAN-00:10 14185.34 02-JAN-20:10 10113.80 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 0.00
February 11501.89 01-FEB-00:10 14185.34 01-FEB-20:10 10113.80 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 0.00
March 11501.89 01-MAR-00:10 14185.34 01-MAR-20:10 10113.80 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 0.00
April 11501.89 01-APR-00:10 14185.34 03-APR-19:10 10113.80 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 0.00
May 11501.89 01-MAY-00:10 14185.34 01-MAY-19:10 10113.80 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 0.00
June 11501.89 01-JUN-00:10 14185.34 01-JUN-19:10 10113.80 01-JUN-19:10 0.00 0.00 0.00 0.00 0.00 0.00
July 11501.89 01-JUL-00:10 14185.34 03-JUL-19:10 10113.80 03-JUL-19:10 0.00 0.00 0.00 0.00 0.00 0.00
August 11501.89 01-AUG-00:10 14185.34 01-AUG-19:10 10113.80 01-AUG-19:10 0.00 0.00 0.00 0.00 0.00 0.00
September 11501.89 01-SEP-00:10 14185.34 01-SEP-19:10 10113.80 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 0.00
October 11501.89 01-OCT-23:10 14185.34 02-OCT-19:10 10113.80 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 0.00
November 11501.89 01-NOV-00:10 14185.34 01-NOV-19:10 10113.80 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 0.00
December 11501.89 01-DEC-00:10 14185.34 01-DEC-20:10 10113.80 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 11501.89   14185.34   10113.80   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 11501.89   14185.34   10113.80   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1169.53 02-JAN-00:10 704.41 02-JAN-20:10 685.60 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 843.62 12-JAN-06:02
February 1169.53 01-FEB-00:10 704.41 01-FEB-20:10 685.60 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 811.72 27-FEB-05:03
March 1169.53 01-MAR-00:10 704.41 01-MAR-20:10 685.60 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 705.47 01-MAR-07:00
April 1169.53 01-APR-00:10 704.41 03-APR-19:10 685.60 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 580.54 03-APR-06:00
May 1169.53 01-MAY-00:10 704.41 01-MAY-19:10 685.60 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 262.46 28-MAY-02:00
June 1169.53 01-JUN-00:10 704.41 01-JUN-19:10 685.60 01-JUN-19:10 0.00 0.00 0.00 0.00 48.62 30-JUN-15:00 221.98 02-JUN-04:00
July 1169.53 01-JUL-00:10 704.41 03-JUL-19:10 685.60 03-JUL-19:10 0.00 0.00 0.00 0.00 74.45 29-JUL-17:00 183.48 31-JUL-02:55
August 1169.53 01-AUG-00:10 704.41 01-AUG-19:10 685.60 01-AUG-19:10 0.00 0.00 0.00 0.00 27.88 11-AUG-18:00 290.13 31-AUG-06:00
September 1169.53 01-SEP-00:10 704.41 01-SEP-19:10 685.60 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 334.66 30-SEP-09:00
October 1169.53 01-OCT-23:10 704.41 02-OCT-19:10 685.60 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 567.75 22-OCT-06:50
November 1169.53 01-NOV-00:10 704.41 01-NOV-19:10 685.60 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 717.04 29-NOV-10:00
December 1169.53 01-DEC-00:10 704.41 01-DEC-20:10 685.60 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 785.59 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1169.53   704.41   685.60   0.00 0.00 0.00 0.00 0.00   183.48  
Maximum of Months 1169.53   704.41   685.60   0.00 0.00 0.00 0.00 74.45   843.62  



Table of Contents

Report: PeakSpaceGainsMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1354.32 02-JAN-00:10 815.72 02-JAN-20:10 793.93 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 335.88 12-JAN-06:40
February 1354.32 01-FEB-00:10 815.72 01-FEB-20:10 793.93 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 315.63 27-FEB-06:00
March 1354.32 01-MAR-00:10 815.72 01-MAR-20:10 793.93 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 272.31 01-MAR-07:00
April 1354.32 01-APR-00:10 815.72 03-APR-19:10 793.93 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 225.84 03-APR-06:00
May 1354.32 01-MAY-00:10 815.72 01-MAY-19:10 793.93 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 108.00 27-MAY-04:00
June 1354.32 01-JUN-00:10 815.72 01-JUN-19:10 793.93 01-JUN-19:10 0.00 0.00 0.00 0.00 20.52 30-JUN-15:00 96.10 02-JUN-04:00
July 1354.32 01-JUL-00:10 815.72 03-JUL-19:10 793.93 03-JUL-19:10 0.00 0.00 0.00 0.00 28.65 29-JUL-16:00 80.74 31-JUL-02:55
August 1354.32 01-AUG-00:10 815.72 01-AUG-19:10 793.93 01-AUG-19:10 0.00 0.00 0.00 0.00 8.77 11-AUG-17:00 121.58 31-AUG-06:00
September 1354.32 01-SEP-00:10 815.72 01-SEP-19:10 793.93 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 133.91 29-SEP-07:00
October 1354.32 01-OCT-23:10 815.72 02-OCT-19:10 793.93 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 219.14 22-OCT-06:20
November 1354.32 01-NOV-00:10 815.72 01-NOV-19:10 793.93 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 276.79 29-NOV-10:00
December 1354.32 01-DEC-00:10 815.72 01-DEC-20:10 793.93 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 305.23 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1354.32   815.72   793.93   0.00 0.00 0.00 0.00 0.00   80.74  
Maximum of Months 1354.32   815.72   793.93   0.00 0.00 0.00 0.00 28.65   335.88  



Table of Contents

Report: PeakSpaceGainsMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 286.42 02-JAN-00:10 1360.40 02-JAN-20:10 839.45 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 793.80 12-JAN-06:00
February 286.42 01-FEB-00:10 1360.40 01-FEB-20:10 839.45 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 745.94 27-FEB-05:20
March 286.42 01-MAR-00:10 1360.40 01-MAR-20:10 839.45 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 643.53 01-MAR-07:00
April 286.42 01-APR-00:10 1360.40 03-APR-19:10 839.45 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 529.63 03-APR-06:00
May 286.42 01-MAY-00:10 1360.40 01-MAY-19:10 839.45 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 247.88 27-MAY-07:00
June 286.42 01-JUN-00:10 1360.40 01-JUN-19:10 839.45 01-JUN-19:10 0.00 0.00 0.00 0.00 49.85 30-JUN-15:00 220.69 02-JUN-04:00
July 286.42 01-JUL-00:10 1360.40 03-JUL-19:10 839.45 03-JUL-19:10 0.00 0.00 0.00 0.00 69.00 29-JUL-17:00 183.88 31-JUL-02:55
August 286.42 01-AUG-00:10 1360.40 01-AUG-19:10 839.45 01-AUG-19:10 0.00 0.00 0.00 0.00 25.57 11-AUG-17:00 278.92 31-AUG-06:00
September 286.42 01-SEP-00:10 1360.40 01-SEP-19:10 839.45 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 306.37 29-SEP-07:00
October 286.42 01-OCT-23:10 1360.40 02-OCT-19:10 839.45 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 517.90 22-OCT-06:30
November 286.42 01-NOV-00:10 1360.40 01-NOV-19:10 839.45 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 654.13 29-NOV-10:00
December 286.42 01-DEC-00:10 1360.40 01-DEC-20:10 839.45 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 721.38 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 286.42   1360.40   839.45   0.00 0.00 0.00 0.00 0.00   183.88  
Maximum of Months 286.42   1360.40   839.45   0.00 0.00 0.00 0.00 69.00   793.80  



Table of Contents

Report: PeakSpaceGainsMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 220.32 02-JAN-00:10 227.72 02-JAN-20:10 242.16 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 457.61 12-JAN-07:00
February 220.32 01-FEB-00:10 227.72 01-FEB-20:10 242.16 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 430.37 27-FEB-05:30
March 220.32 01-MAR-00:10 227.72 01-MAR-20:10 242.16 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 371.30 01-MAR-07:00
April 220.32 01-APR-00:10 227.72 03-APR-19:10 242.16 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 305.56 03-APR-06:00
May 220.32 01-MAY-00:10 227.72 01-MAY-19:10 242.16 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 141.60 27-MAY-04:00
June 220.32 01-JUN-00:10 227.72 01-JUN-19:10 242.16 01-JUN-19:10 0.00 0.00 0.00 0.00 29.13 30-JUN-15:00 126.74 02-JUN-04:00
July 220.32 01-JUL-00:10 227.72 03-JUL-19:10 242.16 03-JUL-19:10 0.00 0.00 0.00 0.00 39.83 29-JUL-17:00 104.69 31-JUL-02:55
August 220.32 01-AUG-00:10 227.72 01-AUG-19:10 242.16 01-AUG-19:10 0.00 0.00 0.00 0.00 15.00 11-AUG-17:00 158.66 31-AUG-06:00
September 220.32 01-SEP-00:10 227.72 01-SEP-19:10 242.16 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 176.14 30-SEP-09:00
October 220.32 01-OCT-23:10 227.72 02-OCT-19:10 242.16 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 298.80 22-OCT-06:20
November 220.32 01-NOV-00:10 227.72 01-NOV-19:10 242.16 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 377.40 29-NOV-10:00
December 220.32 01-DEC-00:10 227.72 01-DEC-20:10 242.16 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 416.19 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 220.32   227.72   242.16   0.00 0.00 0.00 0.00 0.00   104.69  
Maximum of Months 220.32   227.72   242.16   0.00 0.00 0.00 0.00 39.83   457.61  



Table of Contents

Report: PeakSpaceGainsMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 907.20 02-JAN-00:10 357.21 02-JAN-20:10 4572.80 02-JAN-20:10 39726.58 02-JAN-20:10 0.00 0.00 0.00 0.00 01-JAN-00:05 1083.86 12-JAN-08:00
February 907.20 01-FEB-00:10 357.21 01-FEB-20:10 4572.80 01-FEB-20:10 39726.58 01-FEB-20:10 0.00 0.00 0.00 0.00 01-FEB-00:03 1013.21 27-FEB-06:10
March 907.20 01-MAR-00:10 357.21 01-MAR-20:10 4572.80 01-MAR-20:10 39726.58 01-MAR-20:10 0.00 0.00 0.00 0.00 01-MAR-00:03 886.25 01-MAR-07:20
April 907.20 01-APR-00:10 357.21 03-APR-19:10 4572.80 03-APR-19:10 39726.58 03-APR-19:10 0.00 0.00 0.00 0.00 01-APR-00:10 773.69 03-APR-06:00
May 907.20 01-MAY-00:10 357.21 01-MAY-19:10 4572.80 01-MAY-19:10 39726.58 01-MAY-19:10 0.00 0.00 0.00 0.00 01-MAY-00:03 368.85 27-MAY-07:10
June 907.20 01-JUN-00:10 357.21 01-JUN-19:10 4572.80 01-JUN-19:10 39726.58 01-JUN-19:10 0.00 0.00 0.00 69.63 30-JUN-15:00 307.82 02-JUN-05:33
July 907.20 01-JUL-00:10 357.21 03-JUL-19:10 4572.80 03-JUL-19:10 39726.58 03-JUL-19:10 0.00 0.00 0.00 105.72 29-JUL-17:00 272.26 31-JUL-05:03
August 907.20 01-AUG-00:10 357.21 01-AUG-19:10 4572.80 01-AUG-19:10 39726.58 01-AUG-19:10 0.00 0.00 0.00 42.30 11-AUG-17:00 409.04 31-AUG-06:00
September 907.20 01-SEP-00:10 357.21 01-SEP-19:10 4572.80 01-SEP-19:10 39726.58 01-SEP-19:10 0.00 0.00 0.00 0.00 01-SEP-00:05 464.94 30-SEP-09:00
October 907.20 01-OCT-23:10 357.21 02-OCT-19:10 4572.80 02-OCT-19:10 39726.58 02-OCT-19:10 0.00 0.00 0.00 0.00 01-OCT-00:10 758.08 22-OCT-07:00
November 907.20 01-NOV-00:10 357.21 01-NOV-19:10 4572.80 01-NOV-19:10 39726.58 01-NOV-19:10 0.00 0.00 0.00 0.00 01-NOV-00:05 922.28 28-NOV-23:00
December 907.20 01-DEC-00:10 357.21 01-DEC-20:10 4572.80 01-DEC-20:10 39726.58 01-DEC-20:10 0.00 0.00 0.00 0.00 01-DEC-00:02 985.07 15-DEC-08:00
                               
Annual Sum or Average                 0.00 0.00 0.00        
Minimum of Months 907.20   357.21   4572.80   39726.58   0.00 0.00 0.00 0.00   272.26  
Maximum of Months 907.20   357.21   4572.80   39726.58   0.00 0.00 0.00 105.72   1083.86  



Table of Contents

Report: PeakSpaceGainsMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 15368.40 02-JAN-00:10 1761.91 02-JAN-20:10 965.27 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 1919.97 12-JAN-06:00
February 15368.40 01-FEB-00:10 1761.91 01-FEB-20:10 965.27 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 1807.81 27-FEB-05:00
March 15368.40 01-MAR-00:10 1761.91 01-MAR-20:10 965.27 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 1559.60 01-MAR-07:00
April 15368.40 01-APR-00:10 1761.91 03-APR-19:30 965.27 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 1283.53 03-APR-06:00
May 15368.40 01-MAY-00:10 1761.91 02-MAY-19:00 965.27 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 604.05 27-MAY-05:00
June 15368.40 01-JUN-00:10 1566.14 02-JUN-20:49 965.27 01-JUN-19:10 0.00 0.00 0.00 0.00 107.51 30-JUN-15:00 537.65 02-JUN-04:00
July 15368.40 01-JUL-00:10 1566.14 17-JUL-20:00 965.27 03-JUL-19:10 0.00 0.00 0.00 0.00 154.66 29-JUL-17:00 468.70 31-JUL-02:55
August 15368.40 01-AUG-00:10 1761.91 17-AUG-19:00 965.27 01-AUG-19:10 0.00 0.00 0.00 0.00 54.66 11-AUG-18:00 665.30 31-AUG-06:00
September 15368.40 01-SEP-00:10 1761.91 01-SEP-19:10 965.27 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 741.48 30-SEP-09:00
October 15368.40 01-OCT-23:10 1761.91 02-OCT-19:10 965.27 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 1255.13 22-OCT-06:20
November 15368.40 01-NOV-00:10 1761.91 01-NOV-19:10 965.27 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 1584.96 29-NOV-10:00
December 15368.40 01-DEC-00:10 1761.91 01-DEC-20:10 965.27 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 1740.98 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 15368.40   1566.14   965.27   0.00 0.00 0.00 0.00 0.00   468.70  
Maximum of Months 15368.40   1761.91   965.27   0.00 0.00 0.00 0.00 154.66   1919.97  



Table of Contents

Report: PeakSpaceGainsMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 45622.98 02-JAN-00:10 10265.18 02-JAN-20:10 10029.21 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 5495.94 12-JAN-06:50
February 45622.98 01-FEB-00:10 10265.18 01-FEB-20:10 10029.21 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 5164.70 27-FEB-05:50
March 45622.98 01-MAR-00:10 10265.18 01-MAR-20:10 10029.21 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 4455.65 01-MAR-07:00
April 45622.98 01-APR-00:10 10265.18 03-APR-19:19 10029.21 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 3739.98 03-APR-06:00
May 45622.98 01-MAY-00:10 10265.18 02-MAY-19:49 10029.21 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 1826.72 27-MAY-04:00
June 45622.98 01-JUN-00:10 10025.66 02-JUN-19:30 10029.21 01-JUN-19:10 0.00 0.00 0.00 0.00 315.27 30-JUN-15:00 1620.48 02-JUN-04:00
July 45622.98 01-JUL-00:10 10025.66 24-JUL-19:49 10029.21 03-JUL-19:10 0.00 0.00 0.00 0.00 444.40 29-JUL-16:00 1351.03 31-JUL-02:55
August 45622.98 01-AUG-00:10 10265.18 07-AUG-19:00 10029.21 01-AUG-19:10 0.00 0.00 0.00 0.00 123.55 11-AUG-17:00 2022.58 31-AUG-06:00
September 45622.98 01-SEP-00:10 10265.18 01-SEP-19:10 10029.21 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 2222.65 30-SEP-06:00
October 45622.98 01-OCT-23:10 10265.18 02-OCT-19:10 10029.21 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 3622.42 22-OCT-07:00
November 45622.98 01-NOV-00:10 10265.18 01-NOV-19:10 10029.21 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 4528.90 29-NOV-10:00
December 45622.98 01-DEC-00:10 10265.18 01-DEC-20:10 10029.21 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 4994.46 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 45622.98   10025.66   10029.21   0.00 0.00 0.00 0.00 0.00   1351.03  
Maximum of Months 45622.98   10265.18   10029.21   0.00 0.00 0.00 0.00 444.40   5495.94  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.50 01-JAN-19:10 237.06 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.35 12-JAN-06:08
February 180.00 01-FEB-00:10 122.50 01-FEB-20:10 237.06 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 475.87 27-FEB-05:10
March 180.00 01-MAR-00:10 122.50 01-MAR-20:10 237.06 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 410.70 01-MAR-07:00
April 180.00 01-APR-00:10 122.50 01-APR-18:10 237.06 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.18 03-APR-06:00
May 180.00 01-MAY-00:10 122.50 01-MAY-19:10 237.06 01-MAY-06:10 0.00 0.00 0.00 0.00 7.00 31-MAY-16:00 153.45 28-MAY-02:00
June 180.00 01-JUN-00:10 122.50 01-JUN-19:10 237.06 01-JUN-06:10 0.00 0.00 0.00 0.00 41.02 30-JUN-15:10 129.96 02-JUN-04:00
July 180.00 01-JUL-00:10 122.50 01-JUL-18:10 237.06 01-JUL-07:10 0.00 0.00 0.00 0.00 58.05 29-JUL-16:30 100.50 31-JUL-03:30
August 180.00 01-AUG-00:10 122.50 01-AUG-19:10 237.06 01-AUG-06:10 0.00 0.00 0.00 0.00 29.44 11-AUG-16:20 169.51 31-AUG-06:00
September 180.00 01-SEP-00:10 122.50 01-SEP-19:10 237.06 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 195.38 30-SEP-09:00
October 180.00 01-OCT-00:10 122.50 01-OCT-18:10 237.06 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 330.72 22-OCT-06:10
November 180.00 01-NOV-00:10 122.50 01-NOV-19:10 237.06 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 417.44 29-NOV-10:00
December 180.00 01-DEC-00:10 122.50 01-DEC-20:10 237.06 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.24 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 0.00   100.50  
Maximum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 58.05   506.35  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.49 01-JAN-19:10 237.03 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.31 12-JAN-06:06
February 180.00 01-FEB-00:10 122.49 01-FEB-20:10 237.03 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 475.84 27-FEB-05:10
March 180.00 01-MAR-00:10 122.49 01-MAR-20:10 237.03 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 410.66 01-MAR-07:00
April 180.00 01-APR-00:10 122.49 01-APR-18:10 237.03 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.16 03-APR-06:00
May 180.00 01-MAY-00:10 122.49 01-MAY-19:10 237.03 01-MAY-06:10 0.00 0.00 0.00 0.00 7.00 31-MAY-16:00 153.44 28-MAY-02:00
June 180.00 01-JUN-00:10 122.49 01-JUN-19:10 237.03 01-JUN-06:10 0.00 0.00 0.00 0.00 41.02 30-JUN-15:08 129.95 02-JUN-04:00
July 180.00 01-JUL-00:10 122.49 01-JUL-18:10 237.03 01-JUL-07:10 0.00 0.00 0.00 0.00 58.05 29-JUL-16:00 100.49 31-JUL-03:20
August 180.00 01-AUG-00:10 122.49 01-AUG-19:10 237.03 01-AUG-06:10 0.00 0.00 0.00 0.00 29.46 11-AUG-16:00 169.50 31-AUG-06:00
September 180.00 01-SEP-00:10 122.49 01-SEP-19:10 237.03 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 195.37 30-SEP-09:00
October 180.00 01-OCT-00:10 122.49 01-OCT-18:10 237.03 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 330.70 22-OCT-06:10
November 180.00 01-NOV-00:10 122.49 01-NOV-19:10 237.03 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 417.41 29-NOV-10:00
December 180.00 01-DEC-00:10 122.49 01-DEC-20:10 237.03 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.21 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 0.00   100.49  
Maximum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 58.05   506.31  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 01-JAN-00:10 76.99 01-JAN-19:10 232.19 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 136.00 12-JAN-08:00
February 0.00 01-FEB-00:10 76.99 01-FEB-20:10 232.19 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 127.62 27-FEB-05:10
March 0.00 01-MAR-00:10 76.99 01-MAR-20:10 232.19 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 109.51 01-MAR-07:00
April 0.00 01-APR-00:10 76.99 01-APR-18:10 232.19 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 91.02 03-APR-06:00
May 0.00 01-MAY-00:10 76.99 01-MAY-19:10 232.19 01-MAY-06:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 44.41 27-MAY-07:20
June 0.00 01-JUN-00:10 76.99 01-JUN-19:10 232.19 01-JUN-06:10 0.00 0.00 0.00 0.00 9.02 30-JUN-15:00 39.46 02-JUN-04:00
July 0.00 01-JUL-00:10 76.99 01-JUL-18:10 232.19 01-JUL-07:10 0.00 0.00 0.00 0.00 12.13 29-JUL-16:00 32.04 31-JUL-02:55
August 0.00 01-AUG-00:10 76.99 01-AUG-19:10 232.19 01-AUG-06:10 0.00 0.00 0.00 0.00 4.11 11-AUG-16:00 50.07 31-AUG-06:00
September 0.00 01-SEP-00:10 76.99 01-SEP-19:10 232.19 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 54.08 30-SEP-09:00
October 0.00 01-OCT-00:10 76.99 01-OCT-18:10 232.19 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 87.37 22-OCT-06:00
November 0.00 01-NOV-00:10 76.99 01-NOV-19:10 232.19 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 111.41 29-NOV-10:00
December 0.00 01-DEC-00:10 76.99 01-DEC-20:10 232.19 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 123.24 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 0.00   76.99   232.19   0.00 0.00 0.00 0.00 0.00   32.04  
Maximum of Months 0.00   76.99   232.19   0.00 0.00 0.00 0.00 12.13   136.00  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 77.01 01-JAN-19:10 232.26 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 141.32 12-JAN-06:10
February 180.00 01-FEB-00:10 77.01 01-FEB-20:10 232.26 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 132.81 27-FEB-05:10
March 180.00 01-MAR-00:10 77.01 01-MAR-20:10 232.26 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 114.62 01-MAR-07:00
April 180.00 01-APR-00:10 77.01 01-APR-18:10 232.26 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 94.38 03-APR-06:00
May 180.00 01-MAY-00:10 77.01 01-MAY-19:10 232.26 01-MAY-06:10 0.00 0.00 0.00 0.00 1.95 31-MAY-16:00 43.21 27-MAY-07:30
June 180.00 01-JUN-00:10 77.01 01-JUN-19:10 232.26 01-JUN-06:10 0.00 0.00 0.00 0.00 11.45 30-JUN-15:10 36.27 02-JUN-04:00
July 180.00 01-JUL-00:10 77.01 01-JUL-18:10 232.26 01-JUL-07:10 0.00 0.00 0.00 0.00 16.20 29-JUL-16:40 28.05 31-JUL-03:22
August 180.00 01-AUG-00:10 77.01 01-AUG-19:10 232.26 01-AUG-06:10 0.00 0.00 0.00 0.00 8.22 11-AUG-16:00 47.31 31-AUG-06:00
September 180.00 01-SEP-00:10 77.01 01-SEP-19:10 232.26 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 54.53 30-SEP-09:00
October 180.00 01-OCT-00:10 77.01 01-OCT-18:10 232.26 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 92.30 22-OCT-06:10
November 180.00 01-NOV-00:10 77.01 01-NOV-19:10 232.26 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 116.50 29-NOV-10:00
December 180.00 01-DEC-00:10 77.01 01-DEC-20:10 232.26 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 128.45 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   77.01   232.26   0.00 0.00 0.00 0.00 0.00   28.05  
Maximum of Months 180.00   77.01   232.26   0.00 0.00 0.00 0.00 16.20   141.32  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.50 01-JAN-19:10 237.06 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.35 12-JAN-06:08
February 180.00 01-FEB-00:10 122.50 01-FEB-20:10 237.06 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 475.87 27-FEB-05:10
March 180.00 01-MAR-00:10 122.50 01-MAR-20:10 237.06 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 410.70 01-MAR-07:00
April 180.00 01-APR-00:10 122.50 01-APR-18:10 237.06 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.18 03-APR-06:00
May 180.00 01-MAY-00:10 122.50 01-MAY-19:10 237.06 01-MAY-06:10 0.00 0.00 0.00 0.00 7.00 31-MAY-16:00 153.45 28-MAY-02:00
June 180.00 01-JUN-00:10 122.50 01-JUN-19:10 237.06 01-JUN-06:10 0.00 0.00 0.00 0.00 41.02 30-JUN-15:10 129.96 02-JUN-04:00
July 180.00 01-JUL-00:10 122.50 01-JUL-18:10 237.06 01-JUL-07:10 0.00 0.00 0.00 0.00 58.05 29-JUL-16:10 100.50 31-JUL-03:30
August 180.00 01-AUG-00:10 122.50 01-AUG-19:10 237.06 01-AUG-06:10 0.00 0.00 0.00 0.00 29.46 11-AUG-16:00 173.13 31-AUG-07:10
September 180.00 01-SEP-00:10 122.50 01-SEP-19:10 237.06 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 199.39 30-SEP-08:00
October 180.00 01-OCT-00:10 122.50 01-OCT-18:10 237.06 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 330.72 22-OCT-06:10
November 180.00 01-NOV-00:10 122.50 01-NOV-19:10 237.06 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 417.44 29-NOV-10:00
December 180.00 01-DEC-00:10 122.50 01-DEC-20:10 237.06 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.25 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 0.00   100.50  
Maximum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 58.05   506.35  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.49 01-JAN-19:10 237.03 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.31 12-JAN-06:06
February 180.00 01-FEB-00:10 122.49 01-FEB-20:10 237.03 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 475.84 27-FEB-05:10
March 180.00 01-MAR-00:10 122.49 01-MAR-20:10 237.03 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 410.66 01-MAR-07:00
April 180.00 01-APR-00:10 122.49 01-APR-18:10 237.03 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.16 03-APR-06:00
May 180.00 01-MAY-00:10 122.49 01-MAY-19:10 237.03 01-MAY-06:10 0.00 0.00 0.00 0.00 7.00 31-MAY-16:00 153.44 28-MAY-02:00
June 180.00 01-JUN-00:10 122.49 01-JUN-19:10 237.03 01-JUN-06:10 0.00 0.00 0.00 0.00 41.02 30-JUN-15:08 129.95 02-JUN-04:00
July 180.00 01-JUL-00:10 122.49 01-JUL-18:10 237.03 01-JUL-07:10 0.00 0.00 0.00 0.00 58.05 29-JUL-16:50 100.49 31-JUL-03:30
August 180.00 01-AUG-00:10 122.49 01-AUG-19:10 237.03 01-AUG-06:10 0.00 0.00 0.00 0.00 29.46 11-AUG-16:00 172.01 31-AUG-07:10
September 180.00 01-SEP-00:10 122.49 01-SEP-19:10 237.03 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 195.96 30-SEP-08:00
October 180.00 01-OCT-00:10 122.49 01-OCT-18:10 237.03 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 330.70 22-OCT-06:10
November 180.00 01-NOV-00:10 122.49 01-NOV-19:10 237.03 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 417.41 29-NOV-10:00
December 180.00 01-DEC-00:10 122.49 01-DEC-20:10 237.03 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.21 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 0.00   100.49  
Maximum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 58.05   506.31  



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2263.36 02-JAN-00:10 2240.78 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 611.16 12-JAN-06:00
February 2263.36 01-FEB-00:10 2240.78 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 574.33 27-FEB-05:30
March 2263.36 01-MAR-00:10 2240.78 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 495.55 01-MAR-07:00
April 2263.36 01-APR-00:10 2240.78 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 407.89 03-APR-06:00
May 2263.36 01-MAY-00:10 2240.78 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 193.80 27-MAY-04:00
June 2263.36 01-JUN-00:10 2240.78 01-JUN-19:10 0.00 0.00 0.00 0.00 0.00 35.43 30-JUN-15:00 173.32 02-JUN-04:00
July 2263.36 01-JUL-00:10 2240.78 03-JUL-19:10 0.00 0.00 0.00 0.00 0.00 50.43 29-JUL-17:00 142.36 31-JUL-02:55
August 2263.36 01-AUG-00:10 2240.78 01-AUG-19:10 0.00 0.00 0.00 0.00 0.00 15.90 11-AUG-17:00 216.73 31-AUG-06:00
September 2263.36 01-SEP-00:10 2240.78 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 235.27 30-SEP-09:00
October 2263.36 01-OCT-23:10 2240.78 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 398.87 22-OCT-06:20
November 2263.36 01-NOV-00:10 2240.78 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 503.69 29-NOV-10:00
December 2263.36 01-DEC-00:10 2240.78 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 555.44 15-DEC-08:00
                           
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00        
Minimum of Months 2263.36   2240.78   0.00 0.00 0.00 0.00 0.00 0.00   142.36  
Maximum of Months 2263.36   2240.78   0.00 0.00 0.00 0.00 0.00 50.43   611.16  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.50 01-JAN-19:10 237.06 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.99 12-JAN-06:08
February 180.00 01-FEB-00:10 122.50 01-FEB-20:10 237.06 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 476.48 27-FEB-05:10
March 180.00 01-MAR-00:10 122.50 01-MAR-20:10 237.06 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 411.28 01-MAR-07:00
April 180.00 01-APR-00:10 122.50 01-APR-18:10 237.06 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.73 03-APR-06:00
May 180.00 01-MAY-00:10 122.50 01-MAY-19:10 237.06 01-MAY-06:10 0.00 0.00 0.00 0.00 6.60 31-MAY-16:00 153.91 28-MAY-02:00
June 180.00 01-JUN-00:10 122.50 01-JUN-19:10 237.06 01-JUN-06:10 0.00 0.00 0.00 0.00 40.64 30-JUN-15:10 130.41 02-JUN-04:00
July 180.00 01-JUL-00:10 122.50 01-JUL-18:10 237.06 01-JUL-07:10 0.00 0.00 0.00 0.00 57.67 29-JUL-16:30 100.95 31-JUL-03:30
August 180.00 01-AUG-00:10 122.50 01-AUG-19:10 237.06 01-AUG-06:10 0.00 0.00 0.00 0.00 29.05 11-AUG-16:30 169.99 31-AUG-06:00
September 180.00 01-SEP-00:10 122.50 01-SEP-19:10 237.06 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 195.87 30-SEP-09:00
October 180.00 01-OCT-00:10 122.50 01-OCT-18:10 237.06 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 331.27 22-OCT-06:10
November 180.00 01-NOV-00:10 122.50 01-NOV-19:10 237.06 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 418.02 29-NOV-10:00
December 180.00 01-DEC-00:10 122.50 01-DEC-20:10 237.06 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.86 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 0.00   100.95  
Maximum of Months 180.00   122.50   237.06   0.00 0.00 0.00 0.00 57.67   506.99  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 122.49 01-JAN-19:10 237.03 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 506.95 12-JAN-06:08
February 180.00 01-FEB-00:10 122.49 01-FEB-20:10 237.03 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 476.45 27-FEB-05:10
March 180.00 01-MAR-00:10 122.49 01-MAR-20:10 237.03 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 411.26 01-MAR-07:00
April 180.00 01-APR-00:10 122.49 01-APR-18:10 237.03 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 338.71 03-APR-06:00
May 180.00 01-MAY-00:10 122.49 01-MAY-19:10 237.03 01-MAY-06:10 0.00 0.00 0.00 0.00 6.59 31-MAY-16:00 153.90 28-MAY-02:00
June 180.00 01-JUN-00:10 122.49 01-JUN-19:10 237.03 01-JUN-06:10 0.00 0.00 0.00 0.00 40.63 30-JUN-15:10 130.40 02-JUN-04:00
July 180.00 01-JUL-00:10 122.49 01-JUL-18:10 237.03 01-JUL-07:10 0.00 0.00 0.00 0.00 57.67 29-JUL-16:00 100.94 31-JUL-03:30
August 180.00 01-AUG-00:10 122.49 01-AUG-19:10 237.03 01-AUG-06:10 0.00 0.00 0.00 0.00 29.07 11-AUG-16:00 169.98 31-AUG-06:00
September 180.00 01-SEP-00:10 122.49 01-SEP-19:10 237.03 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 195.86 30-SEP-09:00
October 180.00 01-OCT-00:10 122.49 01-OCT-18:10 237.03 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 331.24 22-OCT-06:10
November 180.00 01-NOV-00:10 122.49 01-NOV-19:10 237.03 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 418.00 29-NOV-10:00
December 180.00 01-DEC-00:10 122.49 01-DEC-20:10 237.03 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 460.82 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 0.00   100.94  
Maximum of Months 180.00   122.49   237.03   0.00 0.00 0.00 0.00 57.67   506.95  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 180.00 01-JAN-00:10 77.01 01-JAN-19:10 232.26 01-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 259.39 12-JAN-06:10
February 180.00 01-FEB-00:10 77.01 01-FEB-20:10 232.26 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 243.79 27-FEB-05:10
March 180.00 01-MAR-00:10 77.01 01-MAR-20:10 232.26 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 210.43 01-MAR-07:00
April 180.00 01-APR-00:10 77.01 01-APR-18:10 232.26 01-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 173.31 03-APR-06:00
May 180.00 01-MAY-00:10 77.01 01-MAY-19:10 232.26 01-MAY-06:10 0.00 0.00 0.00 0.00 3.37 31-MAY-16:00 78.75 28-MAY-02:00
June 180.00 01-JUN-00:10 77.01 01-JUN-19:10 232.26 01-JUN-06:10 0.00 0.00 0.00 0.00 20.79 30-JUN-15:10 66.72 02-JUN-04:00
July 180.00 01-JUL-00:10 77.01 01-JUL-18:10 232.26 01-JUL-07:10 0.00 0.00 0.00 0.00 29.51 29-JUL-16:30 51.65 31-JUL-03:22
August 180.00 01-AUG-00:10 77.01 01-AUG-19:10 232.26 01-AUG-06:10 0.00 0.00 0.00 0.00 14.87 11-AUG-16:30 86.97 31-AUG-06:00
September 180.00 01-SEP-00:10 77.01 01-SEP-19:10 232.26 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 100.21 30-SEP-09:00
October 180.00 01-OCT-00:10 77.01 01-OCT-18:10 232.26 01-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 169.49 22-OCT-06:10
November 180.00 01-NOV-00:10 77.01 01-NOV-19:10 232.26 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 213.87 29-NOV-10:00
December 180.00 01-DEC-00:10 77.01 01-DEC-20:10 232.26 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 235.79 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 180.00   77.01   232.26   0.00 0.00 0.00 0.00 0.00   51.65  
Maximum of Months 180.00   77.01   232.26   0.00 0.00 0.00 0.00 29.51   259.39  



Table of Contents

Report: PeakSpaceGainsMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 26988.77 02-JAN-00:10 3094.06 02-JAN-20:10 6747.90 01-JAN-07:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 1235.72 12-JAN-07:10
February 26988.77 01-FEB-00:10 3094.06 01-FEB-20:10 6747.90 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 1161.29 27-FEB-05:50
March 26988.77 01-MAR-00:10 3094.06 01-MAR-20:10 6747.90 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 1018.77 01-MAR-00:03
April 26988.77 01-APR-00:10 3094.06 03-APR-19:30 6747.90 01-APR-06:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 876.50 03-APR-06:00
May 26988.77 01-MAY-00:10 2887.79 02-MAY-19:30 6747.90 01-MAY-06:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 426.92 28-MAY-02:00
June 26988.77 01-JUN-00:10 2887.79 02-JUN-19:49 6747.90 01-JUN-06:10 0.00 0.00 0.00 0.00 67.31 30-JUN-15:00 369.70 02-JUN-04:00
July 26988.77 01-JUL-00:10 2750.27 25-JUL-20:00 6747.90 01-JUL-06:10 0.00 0.00 0.00 0.00 94.57 29-JUL-17:00 319.44 31-JUL-04:45
August 26988.77 01-AUG-00:10 3094.06 18-AUG-19:10 6747.90 01-AUG-06:10 0.00 0.00 0.00 0.00 24.26 11-AUG-16:00 467.32 31-AUG-06:00
September 26988.77 01-SEP-00:10 3094.06 01-SEP-19:10 6747.90 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 529.83 30-SEP-06:00
October 26988.77 01-OCT-23:10 3094.06 02-OCT-19:10 6747.90 01-OCT-06:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 862.35 22-OCT-07:00
November 26988.77 01-NOV-00:10 3094.06 01-NOV-19:10 6747.90 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 1018.56 29-NOV-10:00
December 26988.77 01-DEC-00:10 3094.06 01-DEC-20:10 6747.90 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 1123.15 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 26988.77   2750.27   6747.90   0.00 0.00 0.00 0.00 0.00   319.44  
Maximum of Months 26988.77   3094.06   6747.90   0.00 0.00 0.00 0.00 94.57   1235.72  



Table of Contents

Report: PeakSpaceGainsMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 26988.77 02-JAN-00:10 3094.06 02-JAN-20:10 6747.90 01-JAN-07:10 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 1235.75 12-JAN-07:40
February 26988.77 01-FEB-00:10 3094.06 01-FEB-20:10 6747.90 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 1161.26 27-FEB-05:50
March 26988.77 01-MAR-00:10 3094.06 01-MAR-20:10 6747.90 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 1023.12 01-MAR-00:03
April 26988.77 01-APR-00:10 3094.06 03-APR-19:30 6747.90 01-APR-06:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 881.81 03-APR-06:00
May 26988.77 01-MAY-00:10 2887.79 02-MAY-19:30 6747.90 01-MAY-06:10 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 426.92 28-MAY-02:00
June 26988.77 01-JUN-00:10 2887.79 02-JUN-19:49 6747.90 01-JUN-06:10 0.00 0.00 0.00 0.00 67.31 30-JUN-15:00 369.70 02-JUN-04:00
July 26988.77 01-JUL-00:10 2750.27 25-JUL-20:00 6747.90 01-JUL-06:10 0.00 0.00 0.00 0.00 94.57 29-JUL-17:00 320.51 31-JUL-04:45
August 26988.77 01-AUG-00:10 3094.06 18-AUG-19:10 6747.90 01-AUG-06:10 0.00 0.00 0.00 0.00 24.25 11-AUG-16:00 467.33 31-AUG-06:00
September 26988.77 01-SEP-00:10 3094.06 01-SEP-19:10 6747.90 01-SEP-06:10 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 530.44 30-SEP-07:10
October 26988.77 01-OCT-23:10 3094.06 02-OCT-19:10 6747.90 01-OCT-06:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 864.68 22-OCT-07:00
November 26988.77 01-NOV-00:10 3094.06 01-NOV-19:10 6747.90 01-NOV-06:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 1020.07 28-NOV-23:00
December 26988.77 01-DEC-00:10 3094.06 01-DEC-20:10 6747.90 01-DEC-07:10 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 1123.10 15-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 26988.77   2750.27   6747.90   0.00 0.00 0.00 0.00 0.00   320.51  
Maximum of Months 26988.77   3094.06   6747.90   0.00 0.00 0.00 0.00 94.57   1235.75  



Table of Contents

Report: PeakSpaceGainsMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2401.70 02-JAN-00:10 1089.83 02-JAN-20:10 14912.86 01-JAN-07:10 22492.83 01-JAN-16:10 0.00 0.00 0.00 0.00 01-JAN-00:05 1106.28 12-JAN-07:00
February 2401.70 01-FEB-00:10 1089.83 01-FEB-20:10 14912.86 01-FEB-07:10 22492.83 01-FEB-16:10 0.00 0.00 0.00 0.00 01-FEB-00:03 1036.85 27-FEB-05:40
March 2401.70 01-MAR-00:10 1089.83 01-MAR-20:10 14912.86 01-MAR-07:10 22492.83 01-MAR-16:10 0.00 0.00 0.00 0.00 01-MAR-00:03 913.27 01-MAR-08:50
April 2401.70 01-APR-00:10 1089.83 03-APR-19:10 14912.86 01-APR-06:10 22492.83 01-APR-15:09 0.00 0.00 0.00 0.00 01-APR-00:10 790.11 03-APR-06:00
May 2401.70 01-MAY-00:10 1089.83 01-MAY-19:10 14912.86 01-MAY-06:10 22492.83 01-MAY-15:09 0.00 0.00 0.00 0.00 01-MAY-00:03 379.88 27-MAY-07:00
June 2401.70 01-JUN-00:10 1089.83 01-JUN-19:10 14912.86 01-JUN-06:10 22492.83 01-JUN-15:09 0.00 0.00 0.00 60.38 30-JUN-15:00 330.96 02-JUN-04:00
July 2401.70 01-JUL-00:10 1089.83 03-JUL-19:10 14912.86 01-JUL-06:10 22492.83 01-JUL-15:09 0.00 0.00 0.00 84.82 29-JUL-17:00 294.98 31-JUL-04:45
August 2401.70 01-AUG-00:10 1089.83 01-AUG-19:10 14912.86 01-AUG-06:10 22492.83 01-AUG-15:09 0.00 0.00 0.00 21.88 11-AUG-16:00 418.29 31-AUG-06:00
September 2401.70 01-SEP-00:10 1089.83 01-SEP-19:10 14912.86 01-SEP-06:10 22492.83 01-SEP-15:09 0.00 0.00 0.00 0.00 01-SEP-00:05 475.18 30-SEP-09:00
October 2401.70 01-OCT-23:10 1089.83 02-OCT-19:10 14912.86 01-OCT-06:10 22492.83 01-OCT-15:09 0.00 0.00 0.00 0.00 01-OCT-00:10 774.03 22-OCT-06:10
November 2401.70 01-NOV-00:10 1089.83 01-NOV-19:10 14912.86 01-NOV-06:10 22492.83 01-NOV-15:09 0.00 0.00 0.00 0.00 01-NOV-00:05 934.56 30-NOV-21:00
December 2401.70 01-DEC-00:10 1089.83 01-DEC-20:10 14912.86 01-DEC-07:10 22492.83 01-DEC-16:10 0.00 0.00 0.00 0.00 01-DEC-00:02 1011.00 15-DEC-11:50
                               
Annual Sum or Average                 0.00 0.00 0.00        
Minimum of Months 2401.70   1089.83   14912.86   22492.83   0.00 0.00 0.00 0.00   294.98  
Maximum of Months 2401.70   1089.83   14912.86   22492.83   0.00 0.00 0.00 84.82   1106.28  



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2395.44 02-JAN-00:10 2371.52 02-JAN-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 1081.72 12-JAN-06:00
February 2395.44 01-FEB-00:10 2371.52 01-FEB-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 1017.52 27-FEB-06:00
March 2395.44 01-MAR-00:10 2371.52 01-MAR-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 878.01 01-MAR-07:00
April 2395.44 01-APR-00:10 2371.52 03-APR-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 722.87 03-APR-06:00
May 2395.44 01-MAY-00:10 2371.52 01-MAY-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-MAY-00:03 330.39 27-MAY-04:00
June 2395.44 01-JUN-00:10 2371.52 01-JUN-19:10 0.00 0.00 0.00 0.00 0.00 58.96 30-JUN-15:00 300.12 02-JUN-04:00
July 2395.44 01-JUL-00:10 2371.52 03-JUL-19:10 0.00 0.00 0.00 0.00 0.00 82.81 29-JUL-17:00 248.45 31-JUL-02:55
August 2395.44 01-AUG-00:10 2371.52 01-AUG-19:10 0.00 0.00 0.00 0.00 0.00 24.30 11-AUG-18:00 368.43 31-AUG-06:00
September 2395.44 01-SEP-00:10 2371.52 01-SEP-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-SEP-00:05 417.29 30-SEP-09:00
October 2395.44 01-OCT-23:10 2371.52 02-OCT-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 706.91 22-OCT-06:20
November 2395.44 01-NOV-00:10 2371.52 01-NOV-19:10 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 892.49 29-NOV-10:00
December 2395.44 01-DEC-00:10 2371.52 01-DEC-20:10 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 984.06 15-DEC-08:00
                           
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00        
Minimum of Months 2395.44   2371.52   0.00 0.00 0.00 0.00 0.00 0.00   248.45  
Maximum of Months 2395.44   2371.52   0.00 0.00 0.00 0.00 0.00 82.81   1081.72  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 22434.19 11-JAN-21:00 8945.92 14185.34 10113.80 0.00 0.00 0.00 0.00 0.00 0.00
February 15754.04 28-FEB-22:05 23003.78 18914.03 14904.55 0.00 0.00 0.00 0.00 0.00 0.00
March 13996.99 22-MAR-18:58 80513.24 113483.66 86233.46 0.00 0.00 0.00 0.00 0.00 0.00
April 19469.90 23-APR-08:62 38339.64 28371.05 25550.66 0.00 0.00 0.00 0.00 0.00 0.00
May 21081.44 18-MAY-00:52 69011.35 14184.98 15969.16 0.00 0.00 0.00 0.00 0.00 0.00
June 16698.56 03-JUN-03:00 23003.78 3152.46 4258.44 0.00 0.00 0.00 0.00 0.00 0.00
July 21356.48 31-JUL-04:23 34505.68 9456.84 9581.50 0.00 0.00 0.00 0.00 0.00 0.00
August 37113.71 29-AUG-22:01 80513.24 33099.56 29809.10 0.00 0.00 0.00 0.00 0.00 0.00
September 41206.40 06-SEP-23:52 69011.35 18913.67 19162.99 0.00 0.00 0.00 0.00 0.00 0.00
October 36078.89 07-OCT-20:31 62621.41 77231.46 59618.20 0.00 0.00 0.00 0.00 0.00 0.00
November 20124.89 01-NOV-21:00 10223.90 12609.30 9581.50 0.00 0.00 0.00 0.00 0.00 0.00
December 20866.41 15-DEC-08:00 5111.95 7880.79 6387.66 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 13996.99   5111.95 3152.46 4258.44 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 41206.40   80513.24 113483.66 86233.46 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 769.81 30-JAN-12:30 259.90 195.67 252.59 0.00 0.00 0.00 0.00 0.00 606.41
February 2184.94 15-FEB-13:40 259.90 195.67 252.59 0.00 0.00 0.00 0.00 0.00 402.92
March 3643.06 22-MAR-14:51 3898.44 1956.71 2525.91 0.00 0.00 0.00 0.00 0.00 220.56
April 7772.62 13-APR-15:07 5847.66 1761.04 2273.32 0.00 0.00 0.00 0.00 0.00 234.06
May 4760.81 12-MAY-13:30 259.90 195.67 252.59 0.00 0.00 0.00 0.00 0.00 39.23
June 4309.22 29-JUN-14:10 389.84 195.67 252.59 0.00 0.00 0.00 0.00 19.16 0.00
July 5057.87 23-JUL-13:30 259.90 156.54 216.51 0.00 0.00 0.00 0.00 11.43 0.00
August 5870.69 30-AUG-13:08 1299.48 978.35 1262.95 0.00 0.00 0.00 0.00 0.00 185.42
September 5432.31 28-SEP-14:03 3898.44 1956.71 2525.91 0.00 0.00 0.00 0.00 0.00 221.63
October 4761.01 03-OCT-12:45 519.79 391.34 505.18 0.00 0.00 0.00 0.00 0.00 167.22
November 1812.57 08-NOV-13:20 259.90 195.67 252.59 0.00 0.00 0.00 0.00 0.00 455.04
December 0.00 01-DEC-00:02 5847.66 782.68 1082.53 0.00 0.00 0.00 0.00 0.00 639.32
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 0.00   259.90 156.54 216.51 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7772.62   5847.66 1956.71 2525.91 0.00 0.00 0.00 0.00 19.16 639.32



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 975.52 30-JAN-22:10 1354.32 543.81 585.00 0.00 0.00 0.00 0.00 0.00 245.86
February 1174.46 21-FEB-23:03 5417.28 1087.62 1337.15 0.00 0.00 0.00 0.00 0.00 253.50
March 1468.50 22-MAR-18:58 9480.24 6525.72 6769.31 0.00 0.00 0.00 0.00 0.00 90.00
April 2693.18 20-APR-21:29 10834.56 4350.48 4680.02 0.00 0.00 0.00 0.00 0.00 84.24
May 2247.18 18-MAY-00:52 8125.92 815.72 1253.58 0.00 0.00 0.00 0.00 0.00 84.91
June 2002.78 21-JUN-21:00 1203.84 725.08 752.15 0.00 0.00 0.00 0.00 0.00 0.45
July 2160.03 31-JUL-04:23 4062.96 543.81 752.15 0.00 0.00 0.00 0.00 0.00 77.90
August 2495.96 28-AUG-06:00 3160.08 1087.62 1253.58 0.00 0.00 0.00 0.00 0.00 85.71
September 2255.54 03-SEP-01:23 4213.44 725.08 1002.86 0.00 0.00 0.00 0.00 0.00 76.57
October 1897.84 03-OCT-23:20 4062.96 543.81 752.15 0.00 0.00 0.00 0.00 0.00 70.62
November 1056.30 08-NOV-23:05 2708.64 543.81 668.57 0.00 0.00 0.00 0.00 0.00 242.44
December 1028.56 27-DEC-22:20 1354.32 543.81 585.00 0.00 0.00 0.00 0.00 0.00 256.50
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 975.52   1203.84 543.81 585.00 0.00 0.00 0.00 0.00 0.00 0.45
Maximum of Months 2693.18   10834.56 6525.72 6769.31 0.00 0.00 0.00 0.00 0.00 256.50



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 535.81 22-JAN-21:00 190.94 1209.24 795.27 0.00 0.00 0.00 0.00 0.00 309.34
February 823.60 09-FEB-21:00 222.77 1360.40 839.45 0.00 0.00 0.00 0.00 0.00 358.27
March 1175.31 22-MAR-18:58 2004.91 10883.17 7157.39 0.00 0.00 0.00 0.00 0.00 198.92
April 1773.19 23-APR-08:62 954.72 2720.79 2120.71 0.00 0.00 0.00 0.00 0.00 167.63
May 1950.26 18-MAY-00:52 1718.50 1360.40 1325.44 0.00 0.00 0.00 0.00 0.00 192.67
June 1674.63 22-JUN-20:00 222.77 1360.40 839.45 0.00 0.00 0.00 0.00 0.00 24.51
July 1924.63 31-JUL-04:23 859.25 906.93 795.27 0.00 0.00 0.00 0.00 0.00 180.50
August 1957.55 28-AUG-04:42 1145.66 1209.24 1060.35 0.00 0.00 0.00 0.00 0.00 186.79
September 1969.23 03-SEP-01:23 891.07 1209.24 1060.35 0.00 0.00 0.00 0.00 0.00 173.77
October 1577.00 03-OCT-23:20 859.25 906.93 795.27 0.00 0.00 0.00 0.00 0.00 154.42
November 637.31 02-NOV-21:00 254.59 1209.24 795.27 0.00 0.00 0.00 0.00 0.00 354.20
December 557.39 24-DEC-21:00 190.94 1209.24 795.27 0.00 0.00 0.00 0.00 0.00 324.22
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 535.81   190.94 906.93 795.27 0.00 0.00 0.00 0.00 0.00 24.51
Maximum of Months 1969.23   2004.91 10883.17 7157.39 0.00 0.00 0.00 0.00 0.00 358.27



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:05 342.72 151.81 203.92 0.00 0.00 0.00 0.00 0.00 244.19
February 116.72 08-FEB-22:00 195.84 202.41 229.41 0.00 0.00 0.00 0.00 0.00 130.12
March 554.51 22-MAR-15:03 734.40 379.55 535.30 0.00 0.00 0.00 0.00 0.00 99.75
April 836.34 23-APR-08:62 734.40 455.43 611.77 0.00 0.00 0.00 0.00 0.00 94.53
May 927.10 18-MAY-00:52 1321.92 227.73 382.35 0.00 0.00 0.00 0.00 0.00 109.43
June 756.92 03-JUN-03:00 440.64 50.60 101.96 0.00 0.00 0.00 0.00 0.00 87.34
July 923.04 31-JUL-04:23 660.96 151.81 229.41 0.00 0.00 0.00 0.00 0.00 103.23
August 937.43 28-AUG-04:42 881.28 202.41 305.88 0.00 0.00 0.00 0.00 0.00 106.71
September 934.02 03-SEP-01:23 685.44 202.41 305.88 0.00 0.00 0.00 0.00 0.00 98.30
October 744.89 03-OCT-23:20 660.96 151.81 229.41 0.00 0.00 0.00 0.00 0.00 87.24
November 0.00 01-NOV-00:05 440.64 75.91 127.45 0.00 0.00 0.00 0.00 0.00 210.89
December 0.00 01-DEC-00:02 1101.60 253.02 382.35 0.00 0.00 0.00 0.00 0.00 336.49
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 0.00   195.84 50.60 101.96 0.00 0.00 0.00 0.00 0.00 87.24
Maximum of Months 937.43   1321.92 455.43 611.77 0.00 0.00 0.00 0.00 0.00 336.49



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 35341.89 19-JAN-21:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 0.00 543.76
February 36029.13 09-FEB-21:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 0.00 536.24
March 47263.13 22-MAR-18:58 6350.40 2857.71 38989.14 338721.34 0.00 0.00 0.00 0.00 318.89
April 51663.07 13-APR-20:27 4838.40 1905.14 25992.76 225814.22 0.00 0.00 0.00 0.00 353.04
May 50538.97 26-MAY-20:40 4032.00 1587.62 21660.63 188178.52 0.00 0.00 0.00 0.00 330.84
June 38811.26 29-JUN-20:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 14.18 0.00
July 38895.18 21-JUL-20:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 14.05 0.00
August 50837.29 30-AUG-20:57 7257.60 2857.71 38989.14 338721.34 0.00 0.00 0.00 0.00 308.43
September 50614.15 21-SEP-18:49 7056.00 3175.23 43321.27 376357.04 0.00 0.00 0.00 0.00 286.59
October 49304.94 02-OCT-20:00 6350.40 3214.92 41155.21 357539.19 0.00 0.00 0.00 0.00 307.85
November 35484.19 01-NOV-20:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 0.00 516.00
December 34971.25 19-DEC-21:00 705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 0.00 465.24
                       
Annual Sum or Average             0.00 0.00 0.00    
Minimum of Months 34971.25   705.60 357.21 4572.80 39726.58 0.00 0.00 0.00 0.00 0.00
Maximum of Months 51663.07   7257.60 3214.92 43321.27 376357.04 0.00 0.00 0.00 14.18 543.76



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 6652.50 06-JAN-23:00 15368.40 1174.60 711.25 0.00 0.00 0.00 0.00 0.00 645.19
February 8608.33 15-FEB-13:40 3415.20 298.55 355.63 0.00 0.00 0.00 0.00 0.00 902.23
March 16755.71 22-MAR-14:35 20491.20 1194.18 1422.51 0.00 0.00 0.00 0.00 0.00 501.27
April 29194.22 13-APR-15:07 76842.00 2686.91 3200.64 0.00 0.00 0.00 0.00 0.00 520.75
May 20730.31 11-MAY-01:30 61473.60 783.07 812.86 0.00 0.00 0.00 0.00 0.00 389.89
June 15475.17 20-JUN-15:03 51228.00 1791.27 2133.76 0.00 0.00 0.00 0.00 27.76 0.00
July 17224.46 31-JUL-04:33 46105.20 869.21 914.47 0.00 0.00 0.00 0.00 0.00 429.42
August 22706.12 30-AUG-15:03 51228.00 1791.27 2133.76 0.00 0.00 0.00 0.00 0.00 397.93
September 22928.21 28-SEP-15:10 85380.00 2985.45 3556.27 0.00 0.00 0.00 0.00 0.00 474.96
October 20337.75 04-OCT-03:23 61473.60 783.07 812.86 0.00 0.00 0.00 0.00 0.00 399.60
November 7330.39 08-NOV-13:30 3415.20 298.55 355.63 0.00 0.00 0.00 0.00 0.00 1016.80
December 6029.69 19-DEC-22:10 15368.40 1174.60 711.25 0.00 0.00 0.00 0.00 0.00 810.20
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 6029.69   3415.20 298.55 355.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 29194.22   85380.00 2985.45 3556.27 0.00 0.00 0.00 0.00 27.76 1016.80



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 23425.27 30-JAN-23:05 91245.96 6843.46 8445.65 0.00 0.00 0.00 0.00 0.00 3917.10
February 27352.84 21-FEB-23:03 182491.92 13686.91 16891.30 0.00 0.00 0.00 0.00 0.00 4186.78
March 33783.96 22-MAR-15:10 152076.60 15911.03 22169.83 0.00 0.00 0.00 0.00 0.00 1354.79
April 67039.82 20-APR-21:29 364983.84 54747.65 59119.55 0.00 0.00 0.00 0.00 0.00 1378.56
May 66581.01 15-MAY-23:15 182491.92 9124.61 12668.47 0.00 0.00 0.00 0.00 0.00 1339.32
June 60506.21 01-JUN-04:37 273737.88 12728.83 19002.71 0.00 0.00 0.00 0.00 0.00 1317.05
July 56989.70 31-JUL-03:55 182491.92 4562.30 8445.65 0.00 0.00 0.00 0.00 0.00 1317.77
August 63357.44 29-AUG-21:14 456229.80 68434.56 73899.43 0.00 0.00 0.00 0.00 0.00 1445.58
September 66862.66 18-SEP-21:50 456229.80 68434.56 73899.43 0.00 0.00 0.00 0.00 0.00 1349.10
October 59422.03 04-OCT-01:53 136868.94 3421.73 6334.24 0.00 0.00 0.00 0.00 0.00 1234.71
November 25431.38 09-NOV-00:03 182491.92 9124.61 12668.47 0.00 0.00 0.00 0.00 0.00 4059.48
December 26760.00 27-DEC-23:03 182491.92 13686.91 16891.30 0.00 0.00 0.00 0.00 0.00 4232.34
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 23425.27   91245.96 3421.73 6334.24 0.00 0.00 0.00 0.00 0.00 1234.71
Maximum of Months 67039.82   456229.80 68434.56 73899.43 0.00 0.00 0.00 0.00 0.00 4232.34



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 541.08 12-JAN-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 498.74
February 702.31 11-FEB-19:04 819.00 857.53 903.46 0.00 0.00 0.00 0.00 0.00 179.87
March 3139.06 29-MAR-15:01 680.40 240.11 479.39 0.00 0.00 0.00 0.00 0.00 209.62
April 3474.85 13-APR-15:01 874.80 308.71 616.35 0.00 0.00 0.00 0.00 0.00 126.40
May 3684.76 31-MAY-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 9.35
June 3751.30 19-JUN-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 1.35 0.00
July 3544.83 29-JUL-18:02 702.00 735.03 774.39 0.00 0.00 0.00 0.00 30.17 0.00
August 3752.02 10-AUG-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 0.00 0.53
September 3400.02 09-SEP-15:02 324.00 242.57 458.31 0.00 0.00 0.00 0.00 0.00 51.54
October 3327.45 03-OCT-15:01 680.40 240.11 479.39 0.00 0.00 0.00 0.00 0.00 67.74
November 404.96 29-NOV-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 402.05
December 602.62 24-DEC-09:04 378.00 480.22 1143.15 0.00 0.00 0.00 0.00 0.00 148.67
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 404.96   324.00 205.81 410.90 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3752.02   874.80 857.53 1143.15 0.00 0.00 0.00 0.00 30.17 498.74



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 553.14 22-JAN-09:04 378.00 480.16 1143.02 0.00 0.00 0.00 0.00 0.00 199.08
February 793.84 09-FEB-16:04 680.40 240.08 479.33 0.00 0.00 0.00 0.00 0.00 154.29
March 1183.57 20-MAR-15:03 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 103.49
April 3094.06 21-APR-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.00 58.45
May 3282.23 31-MAY-15:02 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 8.86
June 3399.38 19-JUN-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.79 0.00
July 3253.37 29-JUL-18:02 702.00 734.94 774.30 0.00 0.00 0.00 0.00 29.99 0.00
August 3376.74 10-AUG-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.00 0.68
September 3045.92 02-SEP-18:02 702.00 734.94 774.30 0.00 0.00 0.00 0.00 0.00 41.24
October 1424.83 04-OCT-18:03 970.20 763.12 903.35 0.00 0.00 0.00 0.00 0.00 95.81
November 404.73 29-NOV-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 401.94
December 671.41 24-DEC-09:04 378.00 480.16 1143.02 0.00 0.00 0.00 0.00 0.00 148.66
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 404.73   378.00 205.78 410.85 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3399.38   970.20 763.12 1143.02 0.00 0.00 0.00 0.00 29.99 401.94



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 137.79 30-JAN-12:30 0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 93.68
February 194.63 26-FEB-13:30 0.00 25.41 74.82 0.00 0.00 0.00 0.00 0.00 95.41
March 372.51 29-MAR-14:30 0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 62.19
April 904.78 22-APR-13:20 0.00 25.41 74.82 0.00 0.00 0.00 0.00 0.00 15.53
May 885.12 12-MAY-13:20 0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 5.19
June 803.30 30-JUN-12:30 0.00 21.56 67.08 0.00 0.00 0.00 0.00 5.12 0.00
July 945.13 23-JUL-13:30 0.00 25.41 74.82 0.00 0.00 0.00 0.00 3.01 0.00
August 987.54 25-AUG-13:30 0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 3.18
September 832.15 09-SEP-13:10 0.00 25.41 74.82 0.00 0.00 0.00 0.00 0.00 20.15
October 475.21 03-OCT-12:55 0.00 86.23 268.31 0.00 0.00 0.00 0.00 0.00 26.10
November 75.54 08-NOV-14:30 0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 73.80
December 0.00 01-DEC-00:02 0.00 84.69 257.99 0.00 0.00 0.00 0.00 0.00 98.96
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 0.00   0.00 21.56 67.08 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 987.54   0.00 86.23 268.31 0.00 0.00 0.00 0.00 5.12 98.96



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 390.72 12-JAN-08:61 541.80 237.19 776.76 0.00 0.00 0.00 0.00 0.00 140.07
February 587.54 10-FEB-19:04 970.20 479.78 885.15 0.00 0.00 0.00 0.00 0.00 50.09
March 558.34 10-MAR-19:04 970.20 479.78 885.15 0.00 0.00 0.00 0.00 0.00 58.95
April 828.20 30-APR-18:01 819.00 539.08 885.15 0.00 0.00 0.00 0.00 0.00 23.84
May 945.34 31-MAY-18:02 831.60 411.24 758.70 0.00 0.00 0.00 0.00 0.00 2.09
June 1002.17 22-JUN-18:02 831.60 411.24 758.70 0.00 0.00 0.00 0.00 0.75 0.00
July 1006.14 13-JUL-18:02 831.60 411.24 758.70 0.00 0.00 0.00 0.00 2.06 0.00
August 954.59 10-AUG-18:02 831.60 411.24 758.70 0.00 0.00 0.00 0.00 0.75 0.00
September 807.12 02-SEP-15:02 324.00 152.48 449.03 0.00 0.00 0.00 0.00 0.00 8.85
October 587.80 24-OCT-18:04 970.20 479.78 885.15 0.00 0.00 0.00 0.00 0.00 48.94
November 469.41 05-NOV-08:04 378.00 301.88 1119.99 0.00 0.00 0.00 0.00 0.00 76.28
December 503.76 24-DEC-19:04 819.00 539.08 885.15 0.00 0.00 0.00 0.00 0.00 50.71
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 390.72   324.00 152.48 449.03 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 1006.14   970.20 539.08 1119.99 0.00 0.00 0.00 0.00 2.06 140.07



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 541.10 12-JAN-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 498.75
February 753.32 10-FEB-19:04 970.20 763.21 903.46 0.00 0.00 0.00 0.00 0.00 179.47
March 3037.57 22-MAR-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 117.42
April 3256.30 13-APR-15:01 874.80 308.71 616.35 0.00 0.00 0.00 0.00 0.00 126.07
May 3456.33 31-MAY-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 9.03
June 3494.02 22-JUN-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 2.11 0.00
July 3425.47 29-JUL-18:02 702.00 735.03 774.39 0.00 0.00 0.00 0.00 30.62 0.00
August 3509.11 10-AUG-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 2.45
September 3185.40 09-SEP-15:02 324.00 242.57 458.31 0.00 0.00 0.00 0.00 0.00 51.22
October 3138.66 03-OCT-15:01 680.40 240.11 479.39 0.00 0.00 0.00 0.00 0.00 67.73
November 404.98 29-NOV-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 402.06
December 642.11 24-DEC-09:04 378.00 480.22 1143.15 0.00 0.00 0.00 0.00 0.00 148.67
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 404.98   324.00 205.81 410.90 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3509.11   970.20 763.21 1143.15 0.00 0.00 0.00 0.00 30.62 498.75



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 540.98 12-JAN-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 498.68
February 817.34 09-FEB-19:04 970.20 763.12 903.35 0.00 0.00 0.00 0.00 0.00 216.36
March 1309.13 10-MAR-09:03 252.00 377.27 792.74 0.00 0.00 0.00 0.00 0.00 216.30
April 2915.12 22-APR-08:62 324.00 411.57 979.73 0.00 0.00 0.00 0.00 0.00 120.99
May 3095.02 31-MAY-15:02 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 8.47
June 3161.36 22-JUN-15:02 583.20 205.78 410.85 0.00 0.00 0.00 0.00 2.04 0.00
July 3169.45 13-JUL-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 9.25 0.00
August 3125.12 10-AUG-15:02 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 1.56
September 2877.67 10-SEP-08:62 324.00 411.57 979.73 0.00 0.00 0.00 0.00 0.00 95.99
October 2546.16 04-OCT-08:61 324.00 485.06 1019.23 0.00 0.00 0.00 0.00 0.00 92.98
November 415.80 04-NOV-08:04 378.00 480.16 1143.02 0.00 0.00 0.00 0.00 0.00 219.41
December 708.85 24-DEC-09:04 378.00 480.16 1143.02 0.00 0.00 0.00 0.00 0.00 148.66
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 415.80   252.00 205.78 410.85 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3169.45   970.20 763.12 1143.02 0.00 0.00 0.00 0.00 9.25 498.68



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 526.56 06-JAN-23:00 2263.36 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 205.14
February 1121.87 09-FEB-22:10 2263.36 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 282.17
March 2309.50 22-MAR-15:41 12574.20 6224.39 0.00 0.00 0.00 0.00 0.00 0.00 136.84
April 3469.97 23-APR-08:62 7544.52 4481.56 0.00 0.00 0.00 0.00 0.00 0.00 131.71
May 3831.44 18-MAY-00:52 13580.14 2240.78 0.00 0.00 0.00 0.00 0.00 0.00 151.71
June 3095.91 17-JUN-06:00 5281.16 2240.78 0.00 0.00 0.00 0.00 0.00 0.00 125.43
July 3708.94 31-JUL-04:23 6790.07 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 139.88
August 3804.80 28-AUG-04:42 9053.42 1991.81 0.00 0.00 0.00 0.00 0.00 0.00 145.81
September 3753.11 03-SEP-01:23 7041.55 1991.81 0.00 0.00 0.00 0.00 0.00 0.00 133.37
October 2933.17 03-OCT-23:20 6790.07 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 116.21
November 682.10 01-NOV-21:10 2263.36 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 264.66
December 520.51 24-DEC-22:00 2011.87 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 228.49
                       
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00    
Minimum of Months 520.51   2011.87 1493.85 0.00 0.00 0.00 0.00 0.00 0.00 116.21
Maximum of Months 3831.44   13580.14 6224.39 0.00 0.00 0.00 0.00 0.00 0.00 282.17



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 538.32 12-JAN-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 498.07
February 481.32 27-FEB-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 450.21
March 3165.84 22-MAR-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 113.16
April 3610.28 21-APR-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 0.00 59.21
May 3835.51 31-MAY-15:02 583.20 205.81 410.90 0.00 0.00 0.00 0.00 0.00 9.81
June 3894.67 19-JUN-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 1.05 0.00
July 3828.00 13-JUL-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 9.47 0.00
August 3903.02 10-AUG-18:02 831.60 654.18 774.39 0.00 0.00 0.00 0.00 0.00 0.95
September 3524.25 09-SEP-15:02 324.00 242.57 458.31 0.00 0.00 0.00 0.00 0.00 51.75
October 3425.13 03-OCT-15:01 680.40 240.11 479.39 0.00 0.00 0.00 0.00 0.00 67.45
November 402.49 29-NOV-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 401.51
December 473.22 15-DEC-08:61 541.80 377.32 792.83 0.00 0.00 0.00 0.00 0.00 452.53
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 402.49   324.00 205.81 410.90 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3903.02   831.60 654.18 792.83 0.00 0.00 0.00 0.00 9.47 498.07



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 538.20 12-JAN-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 498.01
February 480.84 27-FEB-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 450.00
March 1495.18 20-MAR-15:03 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 103.88
April 3190.34 21-APR-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.00 59.00
May 3378.44 31-MAY-15:02 583.20 205.78 410.85 0.00 0.00 0.00 0.00 0.00 9.31
June 3493.76 19-JUN-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.44 0.00
July 3432.27 13-JUL-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 8.90 0.00
August 3473.77 10-AUG-18:02 831.60 654.11 774.30 0.00 0.00 0.00 0.00 0.00 1.10
September 3125.96 02-SEP-18:02 702.00 734.94 774.30 0.00 0.00 0.00 0.00 0.00 41.52
October 1870.68 02-OCT-15:03 972.00 342.97 684.76 0.00 0.00 0.00 0.00 0.00 91.15
November 402.26 29-NOV-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 401.41
December 473.18 15-DEC-08:61 541.80 377.27 792.74 0.00 0.00 0.00 0.00 0.00 452.49
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 402.26   541.80 205.78 410.85 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3493.76   972.00 734.94 792.74 0.00 0.00 0.00 0.00 8.90 498.01



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 386.32 12-JAN-08:61 541.80 237.19 776.76 0.00 0.00 0.00 0.00 0.00 255.50
February 2266.64 15-FEB-16:01 680.40 150.94 469.67 0.00 0.00 0.00 0.00 0.00 114.01
March 2375.35 27-MAR-15:01 680.40 150.94 469.67 0.00 0.00 0.00 0.00 0.00 104.10
April 2447.44 13-APR-15:01 874.80 194.07 603.86 0.00 0.00 0.00 0.00 0.00 65.42
May 2554.71 31-MAY-15:02 583.20 129.38 402.58 0.00 0.00 0.00 0.00 0.00 5.00
June 2549.17 22-JUN-15:02 583.20 129.38 402.58 0.00 0.00 0.00 0.00 1.10 0.00
July 2514.92 13-JUL-18:02 831.60 411.24 758.70 0.00 0.00 0.00 0.00 5.27 0.00
August 2610.34 10-AUG-15:02 583.20 129.38 402.58 0.00 0.00 0.00 0.00 0.00 1.84
September 2420.36 28-SEP-15:01 972.00 215.63 670.96 0.00 0.00 0.00 0.00 0.00 59.76
October 2373.93 03-OCT-15:01 680.40 150.94 469.67 0.00 0.00 0.00 0.00 0.00 35.73
November 1256.09 08-NOV-16:01 680.40 150.94 469.67 0.00 0.00 0.00 0.00 0.00 147.93
December 357.22 24-DEC-09:04 378.00 301.88 1119.99 0.00 0.00 0.00 0.00 0.00 76.30
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 357.22   378.00 129.38 402.58 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 2610.34   972.00 411.24 1119.99 0.00 0.00 0.00 0.00 5.27 255.50



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 16009.88 11-JAN-22:08 134943.84 10313.52 33739.51 0.00 0.00 0.00 0.00 0.00 1140.69
February 15732.95 08-FEB-23:00 26988.77 2062.70 6747.90 0.00 0.00 0.00 0.00 0.00 447.75
March 21246.79 22-MAR-15:10 89962.56 4125.41 40487.42 0.00 0.00 0.00 0.00 0.00 322.60
April 34560.48 22-APR-22:09 167930.11 8250.81 53983.22 0.00 0.00 0.00 0.00 0.00 310.50
May 33122.64 10-MAY-00:46 242898.91 4641.08 20243.71 0.00 0.00 0.00 0.00 0.00 309.20
June 31727.99 19-JUN-04:33 80966.30 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 289.10
July 31499.94 31-JUL-04:33 80966.30 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 296.38
August 35119.39 29-AUG-22:01 188921.38 7219.46 47235.32 0.00 0.00 0.00 0.00 0.00 354.55
September 35172.11 14-SEP-22:50 269887.68 10313.52 67479.03 0.00 0.00 0.00 0.00 0.00 319.85
October 30995.98 02-OCT-04:45 107955.07 2750.27 8997.20 0.00 0.00 0.00 0.00 0.00 311.45
November 14406.11 03-NOV-22:00 26988.77 2062.70 6747.90 0.00 0.00 0.00 0.00 0.00 540.44
December 14890.21 14-DEC-23:53 107955.07 4125.41 26991.61 0.00 0.00 0.00 0.00 0.00 1049.79
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 14406.11   26988.77 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 289.10
Maximum of Months 35172.11   269887.68 10313.52 67479.03 0.00 0.00 0.00 0.00 0.00 1140.69



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 17415.62 11-JAN-22:04 134943.84 10313.52 33739.51 0.00 0.00 0.00 0.00 0.00 1140.69
February 17816.42 08-FEB-22:10 26988.77 2062.70 6747.90 0.00 0.00 0.00 0.00 0.00 412.05
March 26073.98 22-MAR-15:10 89962.56 4125.41 40487.42 0.00 0.00 0.00 0.00 0.00 322.81
April 36253.08 22-APR-22:09 167930.11 8250.81 53983.22 0.00 0.00 0.00 0.00 0.00 310.93
May 37461.70 10-MAY-00:46 242898.91 4641.08 20243.71 0.00 0.00 0.00 0.00 0.00 309.56
June 33329.89 19-JUN-04:33 80966.30 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 289.82
July 33549.38 31-JUL-04:33 80966.30 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 296.35
August 36923.83 29-AUG-22:01 188921.38 7219.46 47235.32 0.00 0.00 0.00 0.00 0.00 355.56
September 38189.63 14-SEP-22:50 269887.68 10313.52 67479.03 0.00 0.00 0.00 0.00 0.00 319.90
October 32672.51 02-OCT-04:45 107955.07 2750.27 8997.20 0.00 0.00 0.00 0.00 0.00 312.87
November 16381.80 03-NOV-22:00 26988.77 2062.70 6747.90 0.00 0.00 0.00 0.00 0.00 540.45
December 15911.40 14-DEC-23:53 107955.07 4125.41 26991.61 0.00 0.00 0.00 0.00 0.00 1054.71
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 15911.40   26988.77 1650.16 6747.90 0.00 0.00 0.00 0.00 0.00 289.82
Maximum of Months 38189.63   269887.68 10313.52 67479.03 0.00 0.00 0.00 0.00 0.00 1140.69



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 24415.53 22-JAN-11:50 800.57 363.28 14912.86 18744.03 0.00 0.00 0.00 0.00 488.72
February 26087.29 09-FEB-11:50 1067.42 605.46 29825.71 37488.05 0.00 0.00 0.00 0.00 421.32
March 36765.44 22-MAR-10:35 5337.12 3027.31 149128.56 187440.26 0.00 0.00 0.00 0.00 367.85
April 40564.27 23-APR-08:62 8005.68 2179.66 89477.13 67478.50 0.00 0.00 0.00 0.00 264.42
May 36257.60 26-MAY-17:30 8005.68 4359.32 89477.13 134956.99 0.00 0.00 0.00 0.00 326.26
June 35287.28 02-JUN-06:00 18679.92 4843.69 125511.30 74976.11 0.00 0.00 0.00 0.00 285.94
July 34120.61 05-JUL-07:14 9606.82 4359.32 134215.70 134956.99 0.00 0.00 0.00 0.00 248.76
August 36556.66 21-AUG-07:31 7471.97 3390.59 104389.99 104966.55 0.00 0.00 0.00 0.00 287.85
September 36921.13 23-SEP-10:37 2401.70 908.19 44738.57 56232.08 0.00 0.00 0.00 0.00 350.30
October 37615.66 03-OCT-10:36 4269.70 2421.85 119302.85 149952.21 0.00 0.00 0.00 0.00 298.68
November 23963.96 04-NOV-10:50 800.57 302.73 14912.86 18744.03 0.00 0.00 0.00 0.00 528.49
December 24577.52 24-DEC-11:50 800.57 363.28 14912.86 18744.03 0.00 0.00 0.00 0.00 346.47
                       
Annual Sum or Average             0.00 0.00 0.00    
Minimum of Months 23963.96   800.57 302.73 14912.86 18744.03 0.00 0.00 0.00 0.00 248.76
Maximum of Months 40564.27   18679.92 4843.69 149128.56 187440.26 0.00 0.00 0.00 0.00 528.49



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 339.01 21-JAN-21:30 1863.12 1844.52 0.00 0.00 0.00 0.00 0.00 0.00 355.36
February 2368.97 09-FEB-13:30 532.32 658.76 0.00 0.00 0.00 0.00 0.00 0.00 336.67
March 4836.67 22-MAR-15:03 7984.80 3952.54 0.00 0.00 0.00 0.00 0.00 0.00 251.72
April 6606.45 23-APR-08:62 7984.80 4743.04 0.00 0.00 0.00 0.00 0.00 0.00 226.05
May 7296.21 18-MAY-00:52 14372.64 2371.52 0.00 0.00 0.00 0.00 0.00 0.00 260.45
June 6397.78 30-JUN-12:40 532.32 658.76 0.00 0.00 0.00 0.00 0.00 31.54 0.00
July 7124.32 23-JUL-13:40 532.32 527.00 0.00 0.00 0.00 0.00 0.00 12.74 0.00
August 7235.64 28-AUG-04:42 9581.76 2108.02 0.00 0.00 0.00 0.00 0.00 0.00 249.84
September 7141.04 03-SEP-01:23 7452.48 2108.02 0.00 0.00 0.00 0.00 0.00 0.00 227.99
October 5745.67 03-OCT-23:20 7186.32 1581.01 0.00 0.00 0.00 0.00 0.00 0.00 204.56
November 199.44 01-NOV-21:10 2395.44 1581.01 0.00 0.00 0.00 0.00 0.00 0.00 469.28
December 340.57 24-DEC-23:00 2129.28 1317.51 0.00 0.00 0.00 0.00 0.00 0.00 376.52
                       
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00    
Minimum of Months 199.44   532.32 527.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7296.21   14372.64 4743.04 0.00 0.00 0.00 0.00 0.00 31.54 469.28



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.391146E+12 239694.77 30-JAN-20:10 0.158684E+13 1597257.76 12-JAN-17:00
February 0.346644E+12 241120.19 08-FEB-20:49 0.130865E+13 1350514.71 28-FEB-21:30
March 0.378687E+12 241577.61 22-MAR-19:19 0.100282E+13 1206984.68 01-MAR-07:10
April 0.378372E+12 251103.67 20-APR-19:30 0.573964E+12 539193.16 02-APR-21:40
May 0.413664E+12 278894.62 31-MAY-18:10 0.500141E+12 468104.72 26-MAY-17:40
June 0.439713E+12 337827.26 20-JUN-19:10 0.456999E+12 406266.92 01-JUN-17:19
July 0.466407E+12 337043.43 11-JUL-19:10 0.466378E+12 407740.40 05-JUL-17:30
August 0.437870E+12 328620.84 11-AUG-19:10 0.474381E+12 418960.19 30-AUG-17:19
September 0.378292E+12 256858.28 08-SEP-19:49 0.510554E+12 471350.91 23-SEP-18:10
October 0.382447E+12 248831.78 04-OCT-19:10 0.736051E+12 635400.74 30-OCT-18:10
November 0.376134E+12 240673.41 27-NOV-20:10 0.147651E+13 1396759.01 30-NOV-17:00
December 0.394279E+12 240101.15 14-DEC-20:10 0.174374E+13 1453517.14 15-DEC-17:10
             
Annual Sum or Average 0.478366E+13     0.108370E+14    
Minimum of Months 0.346644E+12 239694.77   0.456999E+12 406266.92  
Maximum of Months 0.466407E+12 337827.26   0.174374E+13 1597257.76  



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [J] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [J] WATERSYSTEMS:ELECTRICITY [J] COGENERATION:ELECTRICITY []
January 0.660716E+11 0.332388E+11 0.148212E+12 0.553314E+11 0.452133E+11 0.365514E+10 0.00 14039921.41 0.00 0.00 0.266205E+11 0.770614E+10 0.00
February 0.593298E+11 0.248688E+11 0.133859E+12 0.499767E+11 0.395286E+11 0.328784E+10 0.00 0.176971E+09 0.00 0.00 0.240443E+11 0.696324E+10 0.00
March 0.653172E+11 0.216988E+11 0.148223E+12 0.553338E+11 0.422861E+11 0.449534E+10 0.00 0.187980E+10 0.00 0.00 0.266205E+11 0.770416E+10 0.00
April 0.624190E+11 0.152754E+11 0.143397E+12 0.535450E+11 0.433850E+11 0.859267E+10 0.00 0.151482E+11 0.00 0.00 0.241445E+11 0.746514E+10 0.00
May 0.642834E+11 0.998276E+10 0.148223E+12 0.553313E+11 0.498917E+11 0.140352E+11 0.00 0.428224E+11 0.00 0.00 0.161744E+11 0.770412E+10 0.00
June 0.619750E+11 0.556142E+10 0.143446E+12 0.535474E+11 0.514737E+11 0.158663E+11 0.00 0.869446E+11 0.00 0.00 0.833676E+10 0.745690E+10 0.00
July 0.640559E+11 0.773038E+10 0.148174E+12 0.553283E+11 0.526365E+11 0.166618E+11 0.00 0.998428E+11 0.00 0.00 0.897701E+10 0.771250E+10 0.00
August 0.645787E+11 0.133381E+11 0.148234E+12 0.553332E+11 0.507615E+11 0.150987E+11 0.00 0.664656E+11 0.00 0.00 0.110625E+11 0.770430E+10 0.00
September 0.629858E+11 0.185473E+11 0.143408E+12 0.535457E+11 0.452633E+11 0.865691E+10 0.00 0.120585E+11 0.00 0.00 0.212770E+11 0.746616E+10 0.00
October 0.655559E+11 0.250171E+11 0.148201E+12 0.553310E+11 0.439659E+11 0.389363E+10 0.00 0.147705E+10 0.00 0.00 0.261241E+11 0.770348E+10 0.00
November 0.638604E+11 0.300039E+11 0.143462E+12 0.535473E+11 0.436321E+11 0.347027E+10 0.00 21340983.23 0.00 0.00 0.257617E+11 0.745028E+10 0.00
December 0.661408E+11 0.355931E+11 0.148174E+12 0.553302E+11 0.456487E+11 0.395933E+10 0.00 13006676.16 0.00 0.00 0.266205E+11 0.771423E+10 0.00
                           
Annual Sum or Average 0.766573E+12 0.240856E+12 0.174501E+13 0.651481E+12 0.553686E+12 0.101673E+12 0.00 0.326864E+12 0.00 0.00 0.245764E+12 0.907507E+11 0.00
Minimum of Months 0.593298E+11 0.556142E+10 0.133859E+12 0.499767E+11 0.395286E+11 0.328784E+10 0.00 13006676.16 0.00 0.00 0.833676E+10 0.696324E+10 0.00
Maximum of Months 0.661408E+11 0.355931E+11 0.148234E+12 0.553338E+11 0.526365E+11 0.166618E+11 0.00 0.998428E+11 0.00 0.00 0.266205E+11 0.771423E+10 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [J] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [J] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [J] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.151918E+12 0.00 0.112190E+13 0.00 0.313017E+12 0.00 0.00
February 0.137204E+12 0.00 0.888618E+12 0.00 0.282829E+12 0.00 0.00
March 0.152024E+12 0.00 0.537522E+12 0.00 0.313276E+12 0.00 0.00
April 0.146956E+12 0.00 0.123971E+12 0.00 0.303038E+12 0.00 0.00
May 0.151978E+12 0.00 0.359129E+11 0.00 0.312250E+12 0.00 0.00
June 0.147114E+12 0.00 0.118961E+11 0.00 0.297989E+12 0.00 0.00
July 0.151820E+12 0.00 0.110221E+11 0.00 0.303536E+12 0.00 0.00
August 0.152039E+12 0.00 0.214491E+11 0.00 0.300893E+12 0.00 0.00
September 0.146971E+12 0.00 0.727705E+11 0.00 0.290813E+12 0.00 0.00
October 0.151903E+12 0.00 0.281624E+12 0.00 0.302524E+12 0.00 0.00
November 0.147091E+12 0.00 0.103289E+13 0.00 0.296524E+12 0.00 0.00
December 0.151820E+12 0.00 0.128080E+13 0.00 0.311125E+12 0.00 0.00
               
Annual Sum or Average 0.178884E+13 0.00 0.542038E+13 0.00 0.362782E+13 0.00 0.00
Minimum of Months 0.137204E+12 0.00 0.110221E+11 0.00 0.282829E+12 0.00 0.00
Maximum of Months 0.152039E+12 0.00 0.128080E+13 0.00 0.313276E+12 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 62892.57 02-JAN-20:10 15448.40 01-JAN-00:10 89475.41 02-JAN-07:10 39726.11 02-JAN-07:19 23383.20 10-JAN-19:10 2580.35 19-JAN-06:19 0.00 01-JAN-00:10
February 62892.57 01-FEB-20:10 15448.40 01-FEB-00:10 89475.41 01-FEB-07:10 39726.11 01-FEB-07:19 22956.96 25-FEB-19:10 4895.97 15-FEB-16:10 0.00 01-FEB-00:10
March 62892.57 01-MAR-20:10 15448.40 01-MAR-00:10 89475.41 01-MAR-07:10 39726.11 01-MAR-07:19 23880.63 22-MAR-15:30 6138.92 29-MAR-15:09 0.00 01-MAR-00:10
April 62892.57 03-APR-19:30 15448.40 01-APR-00:10 89475.41 03-APR-06:10 39726.11 03-APR-06:19 33499.69 23-APR-18:40 6957.01 22-APR-16:30 0.00 01-APR-00:10
May 62480.03 02-MAY-19:00 15448.40 01-MAY-00:10 89475.41 01-MAY-06:10 39724.33 01-MAY-06:19 40119.54 18-MAY-23:00 7534.92 31-MAY-15:00 0.00 01-MAY-00:10
June 62011.46 02-JUN-19:00 15448.40 01-JUN-00:10 89475.41 01-JUN-06:10 39724.33 01-JUN-06:19 34138.33 21-JUN-20:00 7914.82 20-JUN-20:40 0.00 01-JUN-00:10
July 61369.87 26-JUL-19:49 15448.40 01-JUL-00:10 89475.41 03-JUL-06:10 39724.33 03-JUL-06:19 35118.29 11-JUL-20:10 7970.73 10-JUL-18:10 0.00 01-JUL-00:10
August 62892.57 18-AUG-19:19 15448.40 01-AUG-00:10 89475.41 01-AUG-06:10 39724.33 01-AUG-06:19 45649.25 21-AUG-00:49 7914.25 25-AUG-18:10 0.00 01-AUG-00:10
September 62892.57 01-SEP-19:10 15448.40 01-SEP-00:10 89475.41 01-SEP-06:10 39726.11 11-SEP-06:19 33178.83 15-SEP-21:10 6867.33 09-SEP-16:10 0.00 01-SEP-00:10
October 62892.57 02-OCT-19:10 15448.40 01-OCT-00:10 89475.41 02-OCT-06:10 39726.11 02-OCT-06:19 30565.86 03-OCT-21:49 5847.79 03-OCT-15:09 0.00 01-OCT-00:10
November 62892.57 01-NOV-19:10 15448.40 01-NOV-00:10 89475.41 01-NOV-06:10 39726.11 01-NOV-06:19 23641.23 27-NOV-19:10 4498.60 08-NOV-14:09 0.00 01-NOV-00:10
December 62892.57 01-DEC-20:10 15448.40 01-DEC-00:10 89475.41 01-DEC-07:10 39726.11 01-DEC-07:19 23807.92 11-DEC-19:10 4411.52 24-DEC-06:40 0.00 01-DEC-00:10
                             
Annual Sum or Average                            
Minimum of Months 61369.87   15448.40   89475.41   39724.33   22956.96   2580.35   0.00  
Maximum of Months 62892.57   15448.40   89475.41   39726.11   45649.25   7970.73   0.00  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY {Maximum} [W] HEATRECOVERY:ELECTRICITY {TIMESTAMP} WATERSYSTEMS:ELECTRICITY {Maximum} [W] WATERSYSTEMS:ELECTRICITY {TIMESTAMP} COGENERATION:ELECTRICITY []
January 1061.50 16-JAN-09:09 0.00 0.00 9938.94 01-JAN-00:10 4739.94 12-JAN-07:00 0.00
February 3335.09 15-FEB-16:10 0.00 0.00 9938.94 01-FEB-00:20 4738.77 27-FEB-07:00 0.00
March 15480.28 29-MAR-15:09 0.00 0.00 9938.94 01-MAR-00:20 4738.85 01-MAR-07:19 0.00
April 44523.32 22-APR-15:09 0.00 0.00 9938.94 01-APR-00:10 4738.51 28-APR-18:19 0.00
May 78114.30 31-MAY-15:09 0.00 0.00 9938.94 01-MAY-00:10 4738.32 01-MAY-06:10 0.00
June 106322.22 30-JUN-15:09 0.00 0.00 9938.94 01-JUN-00:10 4738.66 22-JUN-18:10 0.00
July 122158.15 29-JUL-15:09 0.00 0.00 9938.94 01-JUL-01:19 4738.25 10-JUL-06:10 0.00
August 100141.28 11-AUG-18:10 0.00 0.00 9938.94 01-AUG-02:09 4738.28 21-AUG-06:10 0.00
September 43037.30 02-SEP-15:09 0.00 0.00 9938.94 01-SEP-00:49 4738.34 20-SEP-06:10 0.00
October 17321.63 03-OCT-15:09 0.00 0.00 9938.94 01-OCT-00:10 4738.00 30-OCT-18:10 0.00
November 1272.47 08-NOV-13:50 0.00 0.00 9938.94 01-NOV-00:10 4739.85 09-NOV-07:10 0.00
December 1679.03 24-DEC-09:09 0.00 0.00 9938.94 01-DEC-00:10 4738.53 15-DEC-07:40 0.00
                   
Annual Sum or Average     0.00 0.00         0.00
Minimum of Months 1061.50   0.00 0.00 9938.94   4738.00   0.00
Maximum of Months 122158.15   0.00 0.00 9938.94   4739.94   0.00



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY []
January 239694.77 30-JAN-20:10 62892.57 88772.42 15448.40 32151.31 22378.99 2017.05 0.00 0.00 0.00
February 241120.19 08-FEB-20:49 62892.57 88772.42 15448.40 32159.77 20290.68 4208.87 0.00 1023.31 0.00
March 241577.61 22-MAR-19:19 62892.57 88772.42 15448.40 32159.77 20606.00 3977.15 0.00 1817.16 0.00
April 251103.67 20-APR-19:30 60488.76 88772.42 0.00 32156.56 24866.36 6326.97 0.00 22469.15 0.00
May 278894.62 31-MAY-18:10 53571.31 79417.81 0.00 31835.81 25303.73 7394.95 0.00 74398.65 0.00
June 337827.26 20-JUN-19:10 60249.24 88772.42 0.00 32148.47 30526.40 7796.61 0.00 102862.15 0.00
July 337043.43 11-JUL-19:10 60249.24 88772.42 0.00 32148.47 31761.56 7763.97 0.00 100912.15 0.00
August 328620.84 11-AUG-19:10 60488.76 88772.42 0.00 32148.47 30636.99 7776.58 0.00 93350.73 0.00
September 256858.28 08-SEP-19:49 62892.57 88772.42 15448.40 32159.77 23773.98 5710.19 0.00 12740.87 0.00
October 248831.78 04-OCT-19:10 62892.57 88772.42 15448.40 32151.31 26854.90 4307.21 0.00 2228.88 0.00
November 240673.41 27-NOV-20:10 62892.57 88772.42 15448.40 32151.31 23299.51 2069.15 0.00 0.00 0.00
December 240101.15 14-DEC-20:10 62892.57 88772.42 15448.40 32151.31 22670.66 2067.63 0.00 0.00 0.00
                       
Annual Sum or Average                     0.00
Minimum of Months 239694.77   53571.31 79417.81 0.00 31835.81 20290.68 2017.05 0.00 0.00 0.00
Maximum of Months 337827.26   62892.57 88772.42 15448.40 32159.77 31761.56 7796.61 0.00 102862.15 0.00



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS {Maximum} [W] INTERIOREQUIPMENT:NATURALGAS {TIMESTAMP} EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS {Maximum} [W] HEATING:NATURALGAS {TIMESTAMP} COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS {Maximum} [W] WATERSYSTEMS:NATURALGAS {TIMESTAMP} COGENERATION:NATURALGAS []
January 104248.32 02-JAN-18:10 0.00 1290744.00 12-JAN-09:20 0.00 312576.37 11-JAN-21:00 0.00
February 104248.32 01-FEB-18:10 0.00 1184655.87 27-FEB-04:00 0.00 312564.75 13-FEB-21:40 0.00
March 104248.32 01-MAR-18:10 0.00 1017606.16 01-MAR-04:00 0.00 312571.59 21-MAR-20:49 0.00
April 104248.32 01-APR-17:10 0.00 325030.87 03-APR-08:09 0.00 312653.98 18-APR-20:19 0.00
May 104248.32 01-MAY-17:10 0.00 141678.81 19-MAY-00:20 0.00 312557.90 09-MAY-20:49 0.00
June 104248.32 01-JUN-17:10 0.00 87556.47 07-JUN-05:40 0.00 309313.36 01-JUN-20:00 0.00
July 104248.32 01-JUL-17:10 0.00 90823.04 05-JUL-01:49 0.00 303673.63 03-JUL-20:40 0.00
August 104248.32 01-AUG-17:10 0.00 110199.65 28-AUG-05:40 0.00 299369.18 01-AUG-20:49 0.00
September 104248.32 01-SEP-17:10 0.00 175135.12 29-SEP-08:09 0.00 306042.42 15-SEP-20:40 0.00
October 104248.32 02-OCT-17:10 0.00 370337.22 27-OCT-08:09 0.00 302574.95 31-OCT-20:19 0.00
November 104248.32 01-NOV-17:10 0.00 1112560.62 29-NOV-09:20 0.00 307761.16 30-NOV-21:40 0.00
December 104248.32 01-DEC-18:10 0.00 1198658.76 15-DEC-09:20 0.00 312468.56 28-DEC-21:30 0.00
                   
Annual Sum or Average     0.00     0.00     0.00
Minimum of Months 104248.32   0.00 87556.47   0.00 299369.18   0.00
Maximum of Months 104248.32   0.00 1290744.00   0.00 312653.98   0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 35.67 19.83 35.67 19.83 0.00 19.83 0.00 19.83
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 1.83 20.33 1.83 20.33 0.00 20.33 0.00 20.33
                 
Annual Sum or Average 37.50 19.85 37.50 19.85 0.00 19.85 0.00 19.85
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 35.67 20.33 35.67 20.33 0.00 20.33 0.00 20.33



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 1.83 20.33 1.83 20.33 0.00 20.33 0.00 20.33
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 1.83 20.33 1.83 20.33 0.00 20.33 0.00 20.33
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 1.83 20.33 1.83 20.33 0.00 20.33 0.00 20.33



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.50 17.79 0.50 17.79 0.00 17.79 0.00 17.79
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.67 25.02 0.67 25.02
April 0.00 0.00 0.00 0.00 27.17 25.08 27.17 25.08
May 0.00 0.00 0.00 0.00 26.33 24.99 26.33 24.99
June 0.00 0.00 0.00 0.00 2.33 24.99 2.33 24.99
July 0.00 0.00 0.00 0.00 4.00 24.84 4.00 24.84
August 0.00 0.00 0.00 0.00 10.67 25.03 10.67 25.03
September 0.00 0.00 0.00 0.00 39.17 25.03 39.17 25.03
October 0.00 0.00 0.00 0.00 15.17 25.03 15.17 25.03
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.50 17.79 0.50 17.79 125.50 24.97 125.50 25.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.50 17.79 0.50 17.79 39.17 25.08 39.17 25.08



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 16.83 19.55 16.83 19.55 0.00 19.55 0.00 19.55
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.50 24.66 0.50 24.66
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.17 24.56 0.17 24.56
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 5.33 20.22 5.33 20.22 0.00 20.22 0.00 20.22
                 
Annual Sum or Average 22.17 19.71 22.17 19.71 0.67 19.78 0.67 19.85
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 16.83 20.22 16.83 20.22 0.50 24.66 0.50 24.66



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 5.83 20.16 5.83 20.16 0.00 20.16 0.00 20.16
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 5.83 20.16 5.83 20.16 0.00 20.16 0.00 20.16
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5.83 20.16 5.83 20.16 0.00 20.16 0.00 20.16



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.67 21.78 0.67 21.78
July 0.00 0.00 0.00 0.00 0.83 21.81 0.83 21.81
August 0.00 0.00 0.00 0.00 0.33 21.84 0.33 21.84
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   1.83 21.81 1.83 21.81
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.83 21.84 0.83 21.84



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.50 21.70 0.50 21.70
July 0.00 0.00 0.00 0.00 0.67 21.80 0.67 21.80
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   1.17 21.76 1.17 21.76
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.67 21.80 0.67 21.80



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 2.17 20.33 2.17 20.33 0.00 20.33 0.00 20.33
February 0.83 20.46 0.83 20.46 0.00 20.46 0.00 20.46
March 0.17 20.53 0.17 20.53 0.00 20.53 0.00 20.53
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.67 21.78 0.67 21.78
July 0.00 0.00 0.00 0.00 0.83 21.74 0.83 21.74
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 1.83 20.46 1.83 20.46 0.00 20.46 0.00 20.46
December 2.33 20.44 2.33 20.44 0.00 20.44 0.00 20.44
                 
Annual Sum or Average 7.33 20.42 7.33 20.42 1.50 20.54 1.50 20.65
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 2.33 20.53 2.33 20.53 0.83 21.78 0.83 21.78



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.83 21.96 0.83 21.96
June 0.00 0.00 0.00 0.00 7.50 21.95 7.50 21.95
July 0.00 0.00 0.00 0.00 4.33 21.92 4.33 21.92
August 0.00 0.00 0.00 0.00 2.67 21.83 2.67 21.83
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   15.33 21.92 15.33 21.92
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 7.50 21.96 7.50 21.96



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 1.67 21.91 1.67 21.91
June 0.00 0.00 0.00 0.00 12.50 22.02 12.50 22.02
July 0.00 0.00 0.00 0.00 6.50 22.01 6.50 22.01
August 0.00 0.00 0.00 0.00 2.33 21.88 2.33 21.88
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   23.00 22.00 23.00 22.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 12.50 22.02 12.50 22.02



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.83 21.79 0.83 21.79
July 0.00 0.00 0.00 0.00 1.17 21.80 1.17 21.80
August 0.00 0.00 0.00 0.00 0.33 21.86 0.33 21.86
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   2.33 21.81 2.33 21.81
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 1.17 21.86 1.17 21.86



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.50 21.73 0.50 21.73
July 0.00 0.00 0.00 0.00 0.67 21.82 0.67 21.82
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   1.17 21.78 1.17 21.78
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.67 21.82 0.67 21.82



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.33 21.71 0.33 21.71
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.50 21.75 0.50 21.75
July 0.00 0.00 0.00 0.00 1.00 21.84 1.00 21.84
August 0.00 0.00 0.00 0.00 1.33 21.86 1.33 21.86
September 0.00 0.00 0.00 0.00 0.17 21.77 0.17 21.77
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   3.33 21.82 3.33 21.82
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 1.33 21.86 1.33 21.86



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 3.33 24.80 3.33 24.80
May 0.00 0.00 0.00 0.00 8.00 24.74 8.00 24.74
June 0.00 0.00 0.00 0.00 3.33 24.76 3.33 24.76
July 0.00 0.00 0.00 0.00 1.83 24.66 1.83 24.66
August 0.00 0.00 0.00 0.00 2.50 24.71 2.50 24.71
September 0.00 0.00 0.00 0.00 5.67 24.69 5.67 24.69
October 0.00 0.00 0.00 0.00 1.83 24.64 1.83 24.64
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   26.50 24.72 26.50 24.72
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 8.00 24.80 8.00 24.80



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 4.00 24.83 4.00 24.83
May 0.00 0.00 0.00 0.00 9.67 24.75 9.67 24.75
June 0.00 0.00 0.00 0.00 3.67 24.79 3.67 24.79
July 0.00 0.00 0.00 0.00 2.17 24.68 2.17 24.68
August 0.00 0.00 0.00 0.00 2.83 24.72 2.83 24.72
September 0.00 0.00 0.00 0.00 7.17 24.71 7.17 24.71
October 0.00 0.00 0.00 0.00 2.50 24.68 2.50 24.68
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   32.00 24.74 32.00 24.74
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 9.67 24.83 9.67 24.83



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 3.00 25.13 3.00 25.13
April 0.00 0.00 0.00 0.00 47.83 25.12 47.83 25.12
May 0.00 0.00 0.00 0.00 52.50 25.06 52.50 25.06
June 0.00 0.00 0.00 0.00 11.00 24.91 11.00 24.91
July 0.00 0.00 0.00 0.00 8.00 24.96 8.00 24.96
August 0.00 0.00 0.00 0.00 26.17 25.06 26.17 25.06
September 0.00 0.00 0.00 0.00 70.17 25.13 70.17 25.13
October 0.00 0.00 0.00 0.00 24.17 24.99 24.17 24.99
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   242.83 25.08 242.83 25.08
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 70.17 25.13 70.17 25.13



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 22.53 47.83 22.43 47.83 22.35
February 672.00 21.78 125.83 21.67 125.83 21.59
March 744.00 21.71 77.50 21.65 77.50 21.60
April 720.00 22.12 0.00 22.12 0.00 22.12
May 744.00 22.35 0.00 22.35 0.00 22.35
June 720.00 22.58 0.00 22.58 0.00 22.58
July 627.00 23.23 10.83 23.24 0.00 23.24
August 312.00 23.61 25.33 23.64 0.00 23.64
September 373.00 23.86 0.00 23.86 0.00 23.86
October 672.50 23.91 0.00 23.91 0.00 23.91
November 720.00 23.70 0.00 23.70 0.00 23.70
December 744.00 23.13 1.17 23.13 1.17 23.13
             
Annual Sum or Average 7792.50 22.78 288.50 22.73 252.33 22.68
Minimum of Months 312.00 21.71 0.00 21.65 0.00 21.59
Maximum of Months 744.00 23.91 125.83 23.91 125.83 23.91



Table of Contents

Report: ComfortReportSimple55Monthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.94 739.67 20.94 739.67 20.94
February 672.00 21.01 611.50 21.01 611.50 21.00
March 717.17 21.13 489.83 21.08 489.83 21.06
April 615.83 21.32 169.00 21.48 109.83 21.42
May 632.67 21.44 61.50 21.67 0.00 21.67
June 565.33 21.59 92.67 21.90 0.00 21.90
July 559.67 21.47 122.67 21.87 0.00 21.87
August 604.33 21.41 98.33 21.75 0.00 21.75
September 667.33 21.18 48.33 21.30 16.50 21.30
October 731.17 21.05 389.83 21.04 386.50 21.03
November 720.00 21.00 707.50 21.00 707.50 21.00
December 744.00 21.00 744.00 21.00 744.00 21.00
             
Annual Sum or Average 7973.50 21.19 4274.83 21.23 3805.33 21.17
Minimum of Months 559.67 20.94 48.33 20.94 0.00 20.94
Maximum of Months 744.00 21.59 744.00 21.90 744.00 21.90



Table of Contents

Report: ComfortReportSimple55Monthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.04 524.00 21.02 524.00 21.02
February 672.00 21.12 348.50 21.08 348.50 21.06
March 744.00 21.36 156.83 21.30 156.83 21.26
April 717.17 22.45 6.67 22.44 6.67 22.43
May 703.83 23.06 0.00 23.06 0.00 23.06
June 463.00 23.14 34.00 23.19 0.00 23.19
July 374.50 23.03 134.00 23.27 0.00 23.27
August 483.00 23.01 55.50 23.11 0.00 23.11
September 707.67 22.64 0.00 22.64 0.00 22.64
October 744.00 21.67 54.17 21.62 54.17 21.58
November 720.00 21.06 482.17 21.04 482.17 21.03
December 744.00 21.02 620.17 21.01 620.17 21.01
             
Annual Sum or Average 7817.17 21.94 2416.00 21.78 2192.50 21.64
Minimum of Months 374.50 21.02 0.00 21.01 0.00 21.01
Maximum of Months 744.00 23.14 620.17 23.27 620.17 23.27



Table of Contents

Report: ComfortReportSimple55Monthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.00 723.17 21.00 723.17 21.00
February 672.00 21.00 585.33 21.00 585.33 21.00
March 744.00 21.01 551.00 21.01 551.00 21.01
April 720.00 21.42 135.67 21.36 135.67 21.31
May 744.00 22.52 0.00 22.52 0.00 22.52
June 678.33 23.20 3.83 23.20 0.00 23.20
July 591.17 23.21 13.50 23.23 0.00 23.23
August 701.17 22.99 0.67 22.99 0.00 22.99
September 720.00 21.99 0.00 21.99 0.00 21.99
October 744.00 21.16 234.50 21.12 234.50 21.10
November 720.00 21.00 716.83 21.00 716.83 21.00
December 744.00 21.00 722.83 21.00 722.83 21.00
             
Annual Sum or Average 8522.67 21.76 3687.33 21.53 3669.33 21.41
Minimum of Months 591.17 21.00 0.00 21.00 0.00 21.00
Maximum of Months 744.00 23.21 723.17 23.23 723.17 23.23



Table of Contents

Report: ComfortReportSimple55Monthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.00 744.00 21.00 744.00 21.00
February 672.00 21.00 649.50 21.00 649.50 21.00
March 744.00 21.00 632.33 21.00 632.33 21.00
April 720.00 21.26 196.50 21.20 196.50 21.17
May 744.00 22.25 0.00 22.25 0.00 22.25
June 713.83 23.01 0.00 23.01 0.00 23.01
July 713.17 23.09 0.00 23.09 0.00 23.09
August 744.00 22.77 0.00 22.77 0.00 22.77
September 720.00 21.70 0.00 21.70 0.00 21.70
October 744.00 21.06 300.67 21.04 300.67 21.03
November 720.00 21.00 720.00 21.00 720.00 21.00
December 744.00 21.00 744.00 21.00 744.00 21.00
             
Annual Sum or Average 8723.00 21.68 3987.00 21.46 3987.00 21.35
Minimum of Months 672.00 21.00 0.00 21.00 0.00 21.00
Maximum of Months 744.00 23.09 744.00 23.09 744.00 23.09



Table of Contents

Report: ComfortReportSimple55Monthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 412.33 21.98 293.17 22.70 106.00 22.81
February 333.50 22.14 272.83 22.87 99.50 23.01
March 271.83 22.56 373.33 23.27 125.67 23.39
April 232.50 23.22 536.33 23.54 152.67 23.66
May 259.67 23.77 644.17 23.67 223.83 23.77
June 283.67 23.99 669.33 23.60 281.67 23.69
July 317.17 24.00 718.00 23.56 316.83 23.67
August 302.00 23.96 690.33 23.61 293.33 23.71
September 259.67 23.77 635.33 23.67 219.17 23.78
October 238.67 23.02 493.00 23.46 145.17 23.57
November 377.33 22.14 282.50 22.89 100.50 23.03
December 455.33 22.04 281.50 22.74 100.00 22.89
             
Annual Sum or Average 3743.67 22.93 5889.83 23.35 2164.33 23.47
Minimum of Months 232.50 21.98 272.83 22.70 99.50 22.81
Maximum of Months 455.33 24.00 718.00 23.67 316.83 23.78



Table of Contents

Report: ComfortReportSimple55Monthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.97 719.17 20.97 719.17 20.97
February 672.00 21.04 460.67 21.03 460.67 21.02
March 686.50 21.27 194.33 21.29 171.50 21.24
April 552.17 21.97 111.17 22.26 11.17 22.24
May 522.17 22.47 109.67 22.71 0.00 22.71
June 280.17 22.31 226.17 22.93 0.00 22.93
July 268.50 22.20 340.00 22.96 5.67 22.97
August 398.33 22.22 233.83 22.77 3.17 22.77
September 620.83 21.96 56.67 22.12 0.00 22.12
October 724.50 21.30 154.50 21.28 144.50 21.24
November 720.00 21.01 675.83 21.00 675.83 21.00
December 744.00 21.00 735.50 21.00 735.50 21.00
             
Annual Sum or Average 6933.17 21.50 4017.50 21.59 2927.17 21.47
Minimum of Months 268.50 20.97 56.67 20.97 0.00 20.97
Maximum of Months 744.00 22.47 735.50 22.96 735.50 22.97



Table of Contents

Report: ComfortReportSimple55Monthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.20 378.67 21.13 378.67 21.09
February 672.00 21.34 219.33 21.26 219.33 21.21
March 744.00 21.80 47.00 21.75 47.00 21.71
April 649.50 22.80 0.00 22.80 0.00 22.80
May 472.83 23.20 0.17 23.20 0.00 23.20
June 165.83 23.00 180.50 23.49 0.00 23.49
July 125.33 22.97 435.50 23.69 13.17 23.70
August 222.83 22.99 303.50 23.53 5.83 23.54
September 532.17 22.79 1.33 22.80 0.00 22.80
October 742.50 22.07 6.00 22.06 6.00 22.05
November 720.00 21.24 334.33 21.17 334.33 21.13
December 744.00 21.12 492.33 21.08 492.33 21.06
             
Annual Sum or Average 6535.00 21.95 2398.67 22.00 1496.67 21.86
Minimum of Months 125.33 21.12 0.00 21.08 0.00 21.06
Maximum of Months 744.00 23.20 492.33 23.69 492.33 23.70



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.49 672.00 20.49 672.00 20.49
March 744.00 20.70 688.00 20.68 688.00 20.67
April 714.50 21.31 248.33 21.19 248.33 21.11
May 730.50 21.58 7.83 21.57 7.83 21.56
June 647.00 21.50 9.83 21.53 0.00 21.53
July 640.00 21.42 11.83 21.45 0.00 21.45
August 679.83 21.46 8.17 21.48 1.33 21.47
September 718.17 21.22 161.67 21.12 161.67 21.05
October 744.00 20.66 637.17 20.62 637.17 20.61
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.47 744.00 20.47 744.00 20.47
             
Annual Sum or Average 8498.00 20.97 4652.83 20.82 4624.33 20.75
Minimum of Months 640.00 20.47 7.83 20.47 0.00 20.47
Maximum of Months 744.00 21.58 744.00 21.57 744.00 21.56



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.47 672.00 20.47 672.00 20.47
March 744.00 20.51 737.83 20.51 737.83 20.51
April 720.00 20.97 377.83 20.86 377.83 20.81
May 742.67 21.48 7.17 21.47 7.17 21.46
June 694.33 21.60 3.17 21.61 0.00 21.61
July 710.83 21.57 2.83 21.58 0.00 21.58
August 728.50 21.47 10.50 21.46 10.50 21.45
September 720.00 20.97 216.83 20.88 216.83 20.82
October 744.00 20.54 720.00 20.54 720.00 20.53
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.47 744.00 20.47 744.00 20.47
             
Annual Sum or Average 8684.33 20.91 4956.17 20.77 4950.17 20.70
Minimum of Months 672.00 20.47 2.83 20.47 0.00 20.47
Maximum of Months 744.00 21.60 744.00 21.61 744.00 21.61



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.52 744.00 20.52 744.00 20.52
February 672.00 20.55 670.00 20.55 670.00 20.55
March 744.00 20.66 723.17 20.65 723.17 20.65
April 720.00 20.98 410.67 20.93 410.67 20.90
May 744.00 21.34 0.00 21.34 0.00 21.34
June 720.00 21.49 0.00 21.49 0.00 21.49
July 744.00 21.48 0.00 21.48 0.00 21.48
August 744.00 21.35 6.00 21.34 6.00 21.34
September 720.00 21.08 93.50 21.04 93.50 21.00
October 744.00 20.76 548.00 20.71 548.00 20.69
November 720.00 20.52 720.00 20.52 720.00 20.52
December 744.00 20.51 744.00 20.51 744.00 20.51
             
Annual Sum or Average 8760.00 20.94 4659.33 20.82 4659.33 20.76
Minimum of Months 672.00 20.51 0.00 20.51 0.00 20.51
Maximum of Months 744.00 21.49 744.00 21.49 744.00 21.49



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.52 668.50 20.52 668.50 20.51
March 744.00 20.94 598.83 20.87 598.83 20.84
April 712.00 21.45 227.17 21.33 227.17 21.26
May 667.83 21.52 3.33 21.51 3.33 21.51
June 588.17 21.38 22.00 21.45 0.00 21.45
July 594.50 21.33 61.00 21.52 0.00 21.52
August 652.67 21.47 32.67 21.56 0.00 21.56
September 713.17 21.35 127.33 21.27 127.33 21.21
October 744.00 20.76 581.17 20.70 581.17 20.67
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.47 744.00 20.47 744.00 20.47
             
Annual Sum or Average 8296.33 20.99 4530.00 20.87 4414.33 20.79
Minimum of Months 588.17 20.47 3.33 20.47 0.00 20.47
Maximum of Months 744.00 21.52 744.00 21.56 744.00 21.56



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.48 672.00 20.48 672.00 20.48
March 744.00 20.64 697.00 20.63 697.00 20.62
April 720.00 21.21 329.33 21.08 329.33 21.02
May 724.00 21.63 3.83 21.63 3.83 21.62
June 644.00 21.54 6.00 21.56 0.00 21.56
July 631.00 21.44 14.67 21.49 0.00 21.49
August 701.17 21.55 2.67 21.56 1.83 21.55
September 720.00 21.20 177.50 21.10 177.50 21.04
October 744.00 20.62 647.50 20.59 647.50 20.58
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.47 744.00 20.47 744.00 20.47
             
Annual Sum or Average 8508.17 20.96 4758.50 20.82 4737.00 20.74
Minimum of Months 631.00 20.47 2.67 20.47 0.00 20.47
Maximum of Months 744.00 21.63 744.00 21.63 744.00 21.62



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.00 716.83 21.00 716.83 21.00
February 672.00 21.00 591.17 21.00 591.17 21.00
March 744.00 21.02 493.83 21.01 493.83 21.01
April 720.00 21.70 99.17 21.61 99.17 21.55
May 744.00 22.85 0.00 22.85 0.00 22.85
June 672.17 23.41 1.83 23.41 0.00 23.41
July 564.83 23.26 6.17 23.26 0.00 23.26
August 716.67 22.96 0.00 22.96 0.00 22.96
September 720.00 21.79 0.00 21.79 0.00 21.79
October 744.00 21.04 249.67 21.03 249.67 21.02
November 720.00 21.00 720.00 21.00 720.00 21.00
December 744.00 21.00 728.83 21.00 728.83 21.00
             
Annual Sum or Average 8505.67 21.80 3607.50 21.56 3599.50 21.43
Minimum of Months 564.83 21.00 0.00 21.00 0.00 21.00
Maximum of Months 744.00 23.41 728.83 23.41 728.83 23.41



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.47 672.00 20.47 672.00 20.47
March 744.00 20.60 709.50 20.59 709.50 20.58
April 712.67 21.21 329.67 21.08 329.67 21.01
May 725.17 21.53 33.33 21.50 33.33 21.47
June 638.33 21.45 14.17 21.49 0.00 21.49
July 634.17 21.38 20.83 21.44 0.00 21.44
August 678.50 21.41 27.33 21.44 13.83 21.43
September 717.50 21.11 229.33 20.99 229.33 20.92
October 744.00 20.59 713.50 20.58 713.50 20.57
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.46 744.00 20.46 744.00 20.46
             
Annual Sum or Average 8474.33 20.92 4957.67 20.78 4909.17 20.71
Minimum of Months 634.17 20.46 14.17 20.46 0.00 20.46
Maximum of Months 744.00 21.53 744.00 21.50 744.00 21.49



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.47 744.00 20.47 744.00 20.47
February 672.00 20.47 672.00 20.47 672.00 20.47
March 744.00 20.49 742.17 20.49 742.17 20.49
April 719.33 20.88 468.50 20.78 468.50 20.74
May 742.33 21.42 51.00 21.38 51.00 21.35
June 688.50 21.56 4.00 21.57 0.00 21.57
July 700.17 21.52 3.83 21.53 0.00 21.53
August 725.17 21.40 28.33 21.37 28.33 21.35
September 720.00 20.86 308.83 20.75 308.83 20.70
October 744.00 20.50 741.50 20.50 741.50 20.50
November 720.00 20.47 720.00 20.47 720.00 20.47
December 744.00 20.46 744.00 20.46 744.00 20.46
             
Annual Sum or Average 8663.50 20.87 5228.17 20.73 5220.33 20.67
Minimum of Months 672.00 20.46 3.83 20.46 0.00 20.46
Maximum of Months 744.00 21.56 744.00 21.57 744.00 21.57



Table of Contents

Report: ComfortReportSimple55Monthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 20.49 744.00 20.49 744.00 20.49
February 672.00 20.77 623.00 20.71 623.00 20.69
March 732.50 21.13 554.17 21.00 554.17 20.95
April 664.17 21.37 192.17 21.28 189.33 21.22
May 670.33 21.45 13.67 21.45 11.33 21.44
June 619.33 21.40 27.67 21.49 0.00 21.49
July 623.50 21.36 57.17 21.52 0.00 21.52
August 643.83 21.39 48.67 21.52 1.00 21.52
September 680.67 21.30 101.67 21.26 97.33 21.21
October 734.33 20.92 501.50 20.82 501.50 20.78
November 720.00 20.53 715.33 20.53 715.33 20.52
December 744.00 20.47 744.00 20.47 744.00 20.47
             
Annual Sum or Average 8248.67 21.03 4323.00 20.92 4181.00 20.84
Minimum of Months 619.33 20.47 13.67 20.47 0.00 20.47
Maximum of Months 744.00 21.45 744.00 21.52 744.00 21.52



Table of Contents

Report: ComfortReportSimple55Monthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 22.53 126.33 22.31 126.33 22.15
February 658.00 22.63 79.67 22.46 79.67 22.32
March 670.00 23.07 18.00 23.02 18.00 22.97
April 331.50 23.40 2.67 23.41 0.00 23.41
May 19.83 23.46 131.67 24.00 0.00 24.00
June 0.00 0.00 678.83 24.00 0.00 24.00
July 10.00 24.00 739.67 24.00 10.00 24.00
August 20.83 23.60 644.67 23.98 7.83 23.98
September 135.17 23.26 192.83 23.74 0.00 23.74
October 497.83 23.17 2.00 23.18 0.00 23.18
November 720.00 22.57 79.33 22.41 79.33 22.29
December 744.00 22.39 154.17 22.16 154.17 21.99
             
Annual Sum or Average 4551.17 22.78 2849.83 23.07 475.33 22.95
Minimum of Months 0.00 0.00 2.00 22.16 0.00 21.99
Maximum of Months 744.00 24.00 739.67 24.00 154.17 24.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 706.50 22.74 69.50 22.58 69.50 22.46
February 590.83 22.79 34.00 22.69 34.00 22.60
March 555.33 23.21 5.67 23.19 4.83 23.17
April 194.83 23.49 22.67 23.57 0.00 23.57
May 0.00 0.00 328.50 24.06 0.00 24.06
June 0.00 0.00 703.83 24.01 0.00 24.01
July 5.00 23.99 744.00 24.00 5.00 24.00
August 11.17 23.73 693.17 23.99 5.67 23.99
September 49.50 23.35 349.00 23.97 0.00 23.97
October 353.50 23.29 40.33 23.37 0.00 23.37
November 706.67 22.84 46.83 22.72 46.83 22.62
December 729.17 22.63 77.50 22.48 77.50 22.35
             
Annual Sum or Average 3902.50 22.91 3115.00 23.30 243.33 23.23
Minimum of Months 0.00 0.00 5.67 22.48 0.00 22.35
Maximum of Months 729.17 23.99 744.00 24.06 77.50 24.06



Table of Contents

Report: ComfortReportSimple55Monthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 437.83 23.03 523.33 23.50 264.50 23.59
February 434.83 23.29 499.33 23.64 299.50 23.72
March 544.83 23.58 577.00 23.78 434.17 23.84
April 502.00 24.06 636.67 24.05 475.33 24.08
May 549.33 24.15 741.33 24.09 549.33 24.11
June 546.67 24.02 720.00 23.99 546.67 24.00
July 571.50 24.01 744.00 23.99 571.50 24.00
August 558.33 24.06 742.17 24.02 558.33 24.03
September 510.00 24.20 704.00 24.12 510.00 24.15
October 499.00 23.89 633.83 23.94 452.50 23.98
November 426.83 23.17 525.67 23.60 266.33 23.69
December 399.00 22.93 533.17 23.51 220.00 23.60
             
Annual Sum or Average 5980.17 23.74 7580.50 23.88 5148.17 23.93
Minimum of Months 399.00 22.93 499.33 23.50 220.00 23.59
Maximum of Months 571.50 24.20 744.00 24.12 571.50 24.15



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 21.00 744.00 21.00 744.00 21.00
February 672.00 21.00 634.33 21.00 634.33 21.00
March 744.00 21.02 549.00 21.01 549.00 21.01
April 720.00 21.55 115.17 21.47 115.17 21.42
May 738.50 22.57 0.00 22.57 0.00 22.57
June 529.50 23.17 27.50 23.21 0.00 23.21
July 426.00 23.00 74.50 23.14 0.00 23.14
August 621.50 22.67 12.17 22.69 0.00 22.69
September 720.00 21.58 0.00 21.58 0.00 21.58
October 744.00 21.04 270.83 21.03 270.83 21.02
November 720.00 21.00 720.00 21.00 720.00 21.00
December 744.00 21.00 744.00 21.00 744.00 21.00
             
Annual Sum or Average 8123.50 21.62 3891.50 21.45 3777.33 21.34
Minimum of Months 426.00 21.00 0.00 21.00 0.00 21.00
Maximum of Months 744.00 23.17 744.00 23.21 744.00 23.21



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: BASEMENT PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 22.52520 14.90439 -0.2034 6.37565
February 672.00000 21.78419 16.28588 -0.3801 8.44354
March 744.00000 21.71381 18.65729 -0.3860 8.36924
April 720.00000 22.11599 22.85264 -0.2620 6.63066
May 744.00000 22.34704 27.93142 -1.2529 38.02835
June 720.00000 22.58034 41.45001 -1.0795 29.83403
July 744.00000 23.31812 48.68895 -0.7656 17.69435
August 744.00000 23.80487 42.48625 -0.6225 13.30060
September 720.00000 23.92654 32.00632 -0.6442 13.82179
October 744.00000 23.91786 23.47514 0.20922 5.98931
November 720.00000 23.69689 13.55691 0.08489 5.41928
December 744.00000 23.13366 13.14105 -0.0629 5.43190
           
Annual Sum or Average 8760.00000 22.91268 26.35562 -0.4473 13.31086
Minimum of Months 672.00000 21.71381 13.14105 -1.2529 5.41928
Maximum of Months 744.00000 23.92654 48.68895 0.20922 38.02835



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: RETAIL_1_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.94047 13.22386 -0.8193 19.44292
February 672.00000 21.01139 14.24171 -0.7072 15.93947
March 744.00000 21.22157 16.48985 -0.5237 12.18514
April 720.00000 21.68116 20.79094 -0.2489 8.83743
May 744.00000 21.78203 26.26018 -1.2017 38.21225
June 720.00000 22.00132 40.45963 -0.9966 28.85204
July 744.00000 21.95195 50.05069 -0.9547 27.58093
August 744.00000 21.81655 45.01356 -1.0558 32.08631
September 720.00000 21.36732 34.59639 -1.4004 47.22796
October 744.00000 21.09110 24.66658 -0.5230 11.46270
November 720.00000 21.00134 12.51867 -0.7855 18.14861
December 744.00000 20.99707 11.56307 -0.8479 20.28153
           
Annual Sum or Average 8760.00000 21.40733 25.90421 -0.8396 23.38929
Minimum of Months 672.00000 20.94047 11.56307 -1.4004 8.83743
Maximum of Months 744.00000 22.00132 50.05069 -0.2489 47.22796



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: RETAIL_2_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 21.04129 16.01644 -0.5788 12.14956
February 672.00000 21.11608 17.01619 -0.5316 11.13407
March 744.00000 21.36262 19.17453 -0.4346 9.31137
April 720.00000 22.46048 22.79191 -0.1242 6.15211
May 744.00000 23.11340 27.42308 -0.9093 23.02776
June 720.00000 23.39117 40.23075 -0.7131 16.19350
July 744.00000 23.38467 48.91846 -0.6568 14.59518
August 744.00000 23.27829 44.35828 -0.7317 16.93162
September 720.00000 22.66075 35.09683 -1.0308 28.33434
October 744.00000 21.66760 26.71606 -0.3118 7.68022
November 720.00000 21.06157 15.33208 -0.5651 11.79472
December 744.00000 21.02213 14.36676 -0.6034 12.72475
           
Annual Sum or Average 8760.00000 22.13545 27.35940 -0.5997 14.17816
Minimum of Months 672.00000 21.02213 14.36676 -1.0308 6.15211
Maximum of Months 744.00000 23.39117 48.91846 -0.1242 28.33434



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: LAUNDRY_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 22.53620 10.78127 0.32311 10.89801
February 672.00000 22.65871 11.63254 0.37524 11.36570
March 744.00000 22.93553 13.67123 0.48557 12.92939
April 720.00000 23.22761 17.74953 0.62847 15.93335
May 744.00000 23.37412 22.51086 0.05289 9.46845
June 720.00000 23.30514 35.85226 0.15090 9.63541
July 744.00000 23.30770 44.60242 0.21084 10.12872
August 744.00000 23.31786 39.65209 0.16440 9.95336
September 720.00000 23.38280 29.41507 0.05565 9.83514
October 744.00000 23.11738 20.74193 0.58769 14.97693
November 720.00000 22.65056 10.13641 0.35149 10.84110
December 744.00000 22.54907 9.26114 0.30516 10.39809
           
Annual Sum or Average 8760.00000 23.03206 22.24153 0.30718 11.36146
Minimum of Months 672.00000 22.53620 9.26114 0.05289 9.46845
Maximum of Months 744.00000 23.38280 44.60242 0.62847 15.93335



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CAFE_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.96664 17.70192 -0.7118 15.95341
February 672.00000 21.04339 18.75548 -0.5864 12.67679
March 744.00000 21.45552 20.92210 -0.3557 9.35677
April 720.00000 22.38515 24.65395 0.00210 7.31953
May 744.00000 22.80295 29.54290 -0.7796 20.09865
June 720.00000 23.00842 42.94020 -0.5873 14.02051
July 744.00000 22.95363 51.90209 -0.5462 13.38340
August 744.00000 22.81220 47.23077 -0.6452 16.48647
September 720.00000 22.17855 37.67635 -1.0319 30.02812
October 744.00000 21.36451 28.84652 -0.3530 8.68554
November 720.00000 21.00583 17.02677 -0.6782 14.84577
December 744.00000 20.99755 16.06041 -0.7500 17.00583
           
Annual Sum or Average 8760.00000 21.91917 29.51364 -0.5854 14.99025
Minimum of Months 672.00000 20.96664 16.06041 -1.0319 7.31953
Maximum of Months 744.00000 23.00842 51.90209 0.00210 30.02812



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: LOBBY_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 21.20045 18.45155 -0.5221 11.02685
February 672.00000 21.34094 19.43570 -0.4509 9.70416
March 744.00000 21.80096 21.52526 -0.2958 7.43790
April 720.00000 22.91312 25.07080 0.02848 5.81185
May 744.00000 23.46116 29.49064 -0.7226 16.46978
June 720.00000 23.62204 42.17835 -0.5574 11.89848
July 744.00000 23.62773 50.69096 -0.4961 10.59721
August 744.00000 23.56335 46.20725 -0.5607 12.17251
September 720.00000 23.06945 37.02880 -0.8378 20.96479
October 744.00000 22.07494 28.88570 -0.1839 6.64040
November 720.00000 21.24059 17.78756 -0.5022 10.56428
December 744.00000 21.12451 16.86290 -0.5615 11.81568
           
Annual Sum or Average 8760.00000 22.42561 29.53892 -0.4721 11.25991
Minimum of Months 672.00000 21.12451 16.86290 -0.8378 5.81185
Maximum of Months 744.00000 23.62773 50.69096 0.02848 20.96479



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_1_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.46961 17.28314 -0.9469 24.54250
February 672.00000 20.48924 18.33126 -0.8850 22.05887
March 744.00000 20.69907 19.93311 -0.7440 17.23052
April 720.00000 21.32780 24.26611 -0.4179 10.07768
May 744.00000 21.61431 31.34219 -1.3404 43.51938
June 720.00000 21.68410 44.95695 -1.1570 34.68788
July 744.00000 21.68062 52.55263 -1.1290 33.41300
August 744.00000 21.61972 49.45767 -1.2211 37.71675
September 720.00000 21.22119 39.32284 -1.5782 55.32994
October 744.00000 20.66067 28.28768 -0.7079 16.25368
November 720.00000 20.47037 16.46618 -0.9352 24.00088
December 744.00000 20.46782 15.88441 -0.9738 25.63935
           
Annual Sum or Average 8760.00000 21.03663 29.91946 -1.0038 28.73510
Minimum of Months 672.00000 20.46782 15.88441 -1.5782 10.07768
Maximum of Months 744.00000 21.68410 52.55263 -0.4179 55.32994



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_2_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.46852 17.29079 -0.9549 24.89970
February 672.00000 20.47260 18.37079 -0.9184 23.42564
March 744.00000 20.51208 20.12505 -0.8322 20.21480
April 720.00000 20.97400 24.67981 -0.5481 12.36980
May 744.00000 21.48644 31.51409 -1.4247 47.34652
June 720.00000 21.66261 44.95477 -1.1898 35.84309
July 744.00000 21.65024 52.73532 -1.1678 34.79681
August 744.00000 21.50512 49.88685 -1.3025 41.19559
September 720.00000 20.97167 39.82531 -1.7024 61.46298
October 744.00000 20.54497 28.48694 -0.7601 17.85336
November 720.00000 20.46887 16.47753 -0.9495 24.62212
December 744.00000 20.46738 15.88818 -0.9761 25.74679
           
Annual Sum or Average 8760.00000 20.93486 30.09931 -1.0613 30.84526
Minimum of Months 672.00000 20.46738 15.88818 -1.7024 12.36980
Maximum of Months 744.00000 21.66261 52.73532 -0.5481 61.46298



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_3_MULT19_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 0.00000 0.00000 0.00000 0.00000 0.00000
February 0.00000 0.00000 0.00000 0.00000 0.00000
March 0.00000 0.00000 0.00000 0.00000 0.00000
April 0.00000 0.00000 0.00000 0.00000 0.00000
May 0.00000 0.00000 0.00000 0.00000 0.00000
June 0.00000 0.00000 0.00000 0.00000 0.00000
July 0.00000 0.00000 0.00000 0.00000 0.00000
August 0.00000 0.00000 0.00000 0.00000 0.00000
September 0.00000 0.00000 0.00000 0.00000 0.00000
October 0.00000 0.00000 0.00000 0.00000 0.00000
November 0.00000 0.00000 0.00000 0.00000 0.00000
December 0.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 0.00000        
Minimum of Months 0.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 0.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_4_MULT19_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.52157 15.92097 -0.8135 19.60239
February 672.00000 20.54863 16.98177 -0.7895 18.75237
March 744.00000 20.65531 18.74522 -0.7300 16.72264
April 720.00000 20.97806 23.72314 -0.5718 12.17809
May 744.00000 21.33806 30.46944 -1.5468 53.47307
June 720.00000 21.48635 44.07070 -1.3636 43.83336
July 744.00000 21.47693 51.99008 -1.3263 41.90751
August 744.00000 21.34616 48.62588 -1.4321 47.34936
September 720.00000 21.08265 38.51789 -1.6545 59.22403
October 744.00000 20.75517 27.09664 -0.6403 14.10309
November 720.00000 20.52135 15.14109 -0.8145 19.59893
December 744.00000 20.51479 14.47095 -0.8300 20.16747
           
Annual Sum or Average 8760.00000 20.93770 28.89307 -1.0442 30.63888
Minimum of Months 672.00000 20.51479 14.47095 -1.6545 12.17809
Maximum of Months 744.00000 21.48635 51.99008 -0.5718 59.22403



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_5_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.47031 17.28038 -0.9439 24.41785
February 672.00000 20.51631 18.29071 -0.8661 21.38573
March 744.00000 20.94269 19.70259 -0.6584 15.01004
April 720.00000 21.46995 24.16026 -0.3845 9.63868
May 744.00000 21.70086 31.28294 -1.2533 39.67991
June 720.00000 21.72868 44.87881 -1.1096 32.86786
July 744.00000 21.72709 51.77886 -1.0716 31.26410
August 744.00000 21.69240 48.82026 -1.1651 35.38441
September 720.00000 21.36763 39.03871 -1.5029 51.69939
October 744.00000 20.76387 28.11728 -0.6667 15.23716
November 720.00000 20.47124 16.46357 -0.9345 23.98267
December 744.00000 20.46772 15.88428 -0.9733 25.61801
           
Annual Sum or Average 8760.00000 21.11314 29.71848 -0.9614 27.20387
Minimum of Months 672.00000 20.46772 15.88428 -1.5029 9.63868
Maximum of Months 744.00000 21.72868 51.77886 -0.3845 51.69939



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_6_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.46890 17.28830 -0.9520 24.77546
February 672.00000 20.47804 18.35001 -0.9041 22.87326
March 744.00000 20.64441 19.93232 -0.7691 18.07633
April 720.00000 21.20767 24.39074 -0.4981 11.38698
May 744.00000 21.67410 31.28460 -1.3072 41.91640
June 720.00000 21.72511 44.87422 -1.1375 33.82214
July 744.00000 21.72240 51.98521 -1.1018 32.27443
August 744.00000 21.65596 49.07664 -1.2227 37.68213
September 720.00000 21.19883 39.34616 -1.6032 56.54607
October 744.00000 20.62340 28.32601 -0.7241 16.76570
November 720.00000 20.46921 16.47487 -0.9489 24.60510
December 744.00000 20.46728 15.88887 -0.9756 25.72416
           
Annual Sum or Average 8760.00000 21.03112 29.84554 -1.0125 28.89017
Minimum of Months 672.00000 20.46728 15.88887 -1.6032 11.38698
Maximum of Months 744.00000 21.72511 51.98521 -0.4981 56.54607



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_1_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.46580 17.41634 -1.0145 27.33819
February 672.00000 20.47227 18.50286 -0.9537 24.74074
March 744.00000 20.60335 20.18174 -0.8180 19.72758
April 720.00000 21.23336 24.58924 -0.4690 11.32575
May 744.00000 21.57251 31.56273 -1.3826 45.75816
June 720.00000 21.66275 45.37101 -1.1758 35.76140
July 744.00000 21.66030 53.49234 -1.1439 34.28659
August 744.00000 21.57987 50.19360 -1.2541 39.48266
September 720.00000 21.11492 39.88343 -1.6581 59.33711
October 744.00000 20.58956 28.67331 -0.7728 18.30995
November 720.00000 20.46636 16.59588 -1.0036 26.79337
December 744.00000 20.46477 15.99679 -1.0422 28.53061
           
Annual Sum or Average 8760.00000 20.99333 30.28572 -1.0580 30.97456
Minimum of Months 672.00000 20.46477 15.99679 -1.6581 11.32575
Maximum of Months 744.00000 21.66275 53.49234 -0.4690 59.33711



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_2_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.46519 17.42573 -1.0220 27.68935
February 672.00000 20.46784 18.52672 -0.9839 26.05855
March 744.00000 20.49192 20.31668 -0.8938 22.48379
April 720.00000 20.88293 25.02771 -0.6046 13.91354
May 744.00000 21.42002 31.77992 -1.4801 50.26072
June 720.00000 21.63721 45.39342 -1.2124 37.06197
July 744.00000 21.62701 53.76751 -1.1857 35.77654
August 744.00000 21.44802 50.69983 -1.3456 43.46053
September 720.00000 20.85525 40.43832 -1.7926 65.94242
October 744.00000 20.50072 28.84447 -0.8207 19.92611
November 720.00000 20.46538 16.60518 -1.0173 27.42165
December 744.00000 20.46453 16.00165 -1.0444 28.63789
           
Annual Sum or Average 8760.00000 20.89661 30.48383 -1.1176 33.24688
Minimum of Months 672.00000 20.46453 16.00165 -1.7926 13.91354
Maximum of Months 744.00000 21.63721 53.76751 -0.6046 65.94242



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: ROOM_3_MULT9_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.48597 18.76787 -0.9236 23.59745
February 672.00000 20.77292 19.68227 -0.7727 18.69171
March 744.00000 21.16391 21.20600 -0.5726 13.66832
April 720.00000 21.52594 25.93074 -0.3353 9.27412
May 744.00000 21.63964 32.81579 -1.3267 43.43718
June 720.00000 21.67207 45.47499 -1.1903 36.65937
July 744.00000 21.67570 52.84904 -1.1435 34.55296
August 744.00000 21.64572 49.72209 -1.2010 37.38537
September 720.00000 21.41317 40.49021 -1.4681 50.26211
October 744.00000 20.95380 29.44807 -0.5968 13.78362
November 720.00000 20.53218 17.97812 -0.8952 22.49831
December 744.00000 20.46950 17.41717 -0.9633 25.21929
           
Annual Sum or Average 8760.00000 21.16439 31.05844 -0.9503 27.46618
Minimum of Months 672.00000 20.46950 17.41717 -1.4681 9.27412
Maximum of Months 744.00000 21.67570 52.84904 -0.3353 50.26211



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: BANQUET_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 22.52985 21.49997 -0.1987 7.56461
February 672.00000 22.66210 22.33107 -0.1436 7.12933
March 744.00000 23.16479 23.97242 0.01747 6.21159
April 720.00000 23.72160 26.57578 0.23133 6.57219
May 744.00000 23.97953 29.85967 -0.4780 9.87989
June 720.00000 23.99777 42.02176 -0.3221 7.25372
July 744.00000 23.99473 50.45687 -0.2683 6.57679
August 744.00000 23.95987 46.25567 -0.3537 7.82196
September 720.00000 23.84304 37.34350 -0.5457 11.71346
October 744.00000 23.44974 30.22177 0.14876 6.33127
November 720.00000 22.56631 20.95804 -0.1904 7.28358
December 744.00000 22.39266 20.19703 -0.2501 7.77389
           
Annual Sum or Average 8760.00000 23.35892 31.03728 -0.1964 7.67471
Minimum of Months 672.00000 22.39266 20.19703 -0.5457 6.21159
Maximum of Months 744.00000 23.99777 50.45687 0.23133 11.71346



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: DINING_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 22.80329 20.70943 -0.0919 6.90424
February 672.00000 22.93318 21.48536 -0.0385 6.62943
March 744.00000 23.40648 22.97787 0.11527 6.27901
April 720.00000 23.85933 25.62786 0.30222 7.18834
May 744.00000 24.02061 29.15316 -0.4146 8.64951
June 720.00000 24.00529 41.48888 -0.2775 6.68880
July 744.00000 24.00319 49.92258 -0.2235 6.10780
August 744.00000 23.99127 45.58807 -0.2973 6.99633
September 720.00000 23.95004 36.37449 -0.4518 9.54225
October 744.00000 23.66039 29.12323 0.24077 6.81990
November 720.00000 22.85837 20.17517 -0.0794 6.60267
December 744.00000 22.66041 19.51271 -0.1450 6.95848
           
Annual Sum or Average 8760.00000 23.51571 30.24159 -0.1139 7.11359
Minimum of Months 672.00000 22.66041 19.51271 -0.4518 6.10780
Maximum of Months 744.00000 24.02061 49.92258 0.30222 9.54225



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: KITCHEN_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 23.29256 19.63047 0.61311 17.23806
February 672.00000 23.43170 20.04480 0.68796 19.22786
March 744.00000 23.59023 21.15860 0.80435 22.55292
April 720.00000 23.89131 24.65468 0.98556 28.43030
May 744.00000 24.04184 28.77043 0.59810 17.16159
June 720.00000 23.97742 40.91194 0.71340 19.47178
July 744.00000 23.97190 49.13581 0.76784 21.35415
August 744.00000 23.98778 44.70388 0.68969 19.25955
September 720.00000 24.03675 35.65112 0.52827 15.75786
October 744.00000 23.77987 27.75780 0.90107 24.83652
November 720.00000 23.42520 18.91317 0.64706 17.74003
December 744.00000 23.33837 18.39189 0.59794 16.80324
           
Annual Sum or Average 8760.00000 23.73175 29.20876 0.71131 19.98840
Minimum of Months 672.00000 23.29256 18.39189 0.52827 15.75786
Maximum of Months 744.00000 24.04184 49.13581 0.98556 28.43030



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: STORAGE_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.99662 12.76013 -0.6691 14.47484
February 672.00000 21.00016 13.80139 -0.6488 13.93095
March 744.00000 21.00067 16.03596 -0.6068 12.80346
April 720.00000 21.25507 20.60444 -0.4696 9.86589
May 744.00000 22.25394 25.19829 -1.2651 38.65289
June 720.00000 23.01152 37.82864 -0.9212 23.14600
July 744.00000 23.11299 46.53383 -0.8286 19.76966
August 744.00000 22.77205 42.32610 -0.9763 25.57462
September 720.00000 21.69852 33.41403 -1.4088 46.16167
October 744.00000 21.05619 24.14635 -0.5195 10.78889
November 720.00000 21.00017 12.07258 -0.6645 14.32202
December 744.00000 21.00018 11.08538 -0.6850 14.91575
           
Annual Sum or Average 8760.00000 21.68475 24.72520 -0.8059 20.38717
Minimum of Months 672.00000 20.99662 11.08538 -1.4088 9.86589
Maximum of Months 744.00000 23.11299 46.53383 -0.4696 46.16167



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORRIDOR_FLR_3 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.99841 15.88076 -0.6322 13.44621
February 672.00000 21.00050 16.95626 -0.6062 12.77226
March 744.00000 21.01508 19.26289 -0.5602 11.63051
April 720.00000 21.69764 23.33617 -0.3482 8.09644
May 744.00000 22.84543 27.58605 -1.0640 29.18961
June 720.00000 23.43697 40.07728 -0.7724 17.78623
July 744.00000 23.38011 48.87852 -0.7333 16.63049
August 744.00000 22.99228 44.95616 -0.8988 22.55107
September 720.00000 21.78679 36.37200 -1.3801 44.76159
October 744.00000 21.04132 27.36941 -0.5092 10.51279
November 720.00000 21.00056 15.22167 -0.6302 13.37436
December 744.00000 21.00060 14.19230 -0.6479 13.86131
           
Annual Sum or Average 8760.00000 21.85519 27.58054 -0.7324 17.89223
Minimum of Months 672.00000 20.99841 14.19230 -1.3801 8.09644
Maximum of Months 744.00000 23.43697 48.87852 -0.3482 44.76159



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORRIDOR_FLR_6 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 20.99885 13.88581 -0.6856 14.97630
February 672.00000 21.00056 14.92928 -0.6498 13.98601
March 744.00000 21.01741 17.25297 -0.5801 12.17768
April 720.00000 21.54832 21.50004 -0.3706 8.50054
May 744.00000 22.57590 25.79210 -1.1050 31.37393
June 720.00000 23.35462 38.04681 -0.7401 17.03203
July 744.00000 23.32714 46.81955 -0.6903 15.65053
August 744.00000 22.84792 42.99594 -0.8939 22.90450
September 720.00000 21.58265 34.72498 -1.4148 46.56983
October 744.00000 21.03777 25.37802 -0.5172 10.73272
November 720.00000 21.00061 13.19817 -0.6833 14.87835
December 744.00000 21.00064 12.20456 -0.7077 15.61459
           
Annual Sum or Average 8760.00000 21.77966 25.63375 -0.7535 18.70512
Minimum of Months 672.00000 20.99885 12.20456 -1.4148 8.50054
Maximum of Months 744.00000 23.35462 46.81955 -0.3706 46.56983



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: MECH_FLR_1 PEOPLE

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 744.00000 21.00010 12.28724 -0.6429 13.74410
February 672.00000 21.00096 13.31932 -0.6238 13.26045
March 744.00000 21.01387 15.55730 -0.5815 12.18227
April 720.00000 21.42421 19.93227 -0.4203 9.06358
May 744.00000 22.52371 24.27125 -1.1668 33.91853
June 720.00000 23.23737 36.75229 -0.8347 19.99775
July 744.00000 23.33274 45.33194 -0.7435 16.98388
August 744.00000 23.03835 41.07919 -0.8776 21.77595
September 720.00000 21.99410 32.33249 -1.3014 40.72611
October 744.00000 21.15651 23.52407 -0.4784 10.01716
November 720.00000 21.00007 11.59480 -0.6375 13.57871
December 744.00000 21.00008 10.60722 -0.6603 14.21278
           
Annual Sum or Average 8760.00000 21.81568 23.95534 -0.7479 18.30179
Minimum of Months 672.00000 21.00007 10.60722 -1.3014 9.06358
Maximum of Months 744.00000 23.33274 45.33194 -0.4203 40.72611



Table of Contents

Report: ChillerReportMonthly

For: COOLSYS1 CHILLER1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

CHILLER ELECTRICITY ENERGY [J] CHILLER ELECTRICITY RATE {Maximum} [W] CHILLER ELECTRICITY RATE {TIMESTAMP} CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] CHILLER EVAPORATOR COOLING ENERGY [J] CHILLER EVAPORATOR COOLING RATE [] CHILLER CONDENSER HEAT TRANSFER ENERGY [J] CHILLER COP [W/W] CHILLER COP {Maximum} [W/W] CHILLER COP {TIMESTAMP} CHILLER PART LOAD RATIO [] CHILLER PART LOAD RATIO []
January 14039921.41 7430.49 16-JAN-09:04 1.23 44737303.01 0.00 58777224.42 0.01 3.19 06-JAN-19:06 0.00 0.00
February 0.176971E+09 19851.20 09-FEB-09:04 28.20 0.563906E+09 0.00 0.740877E+09 0.13 3.19 09-FEB-16:15 0.00 0.00
March 0.187980E+10 20287.68 29-MAR-15:06 164.56 0.598985E+10 0.00 0.786965E+10 0.70 3.19 02-MAR-15:30 0.00 0.00
April 0.151482E+11 50585.01 22-APR-15:02 454.96 0.481528E+11 0.00 0.633010E+11 2.01 3.59 22-APR-15:02 0.00 0.00
May 0.428224E+11 86605.25 31-MAY-15:03 713.46 0.136125E+12 0.00 0.178947E+12 3.04 4.07 31-MAY-15:03 0.00 0.00
June 0.869446E+11 115517.27 30-JUN-15:03 713.65 0.289025E+12 0.00 0.375969E+12 3.19 4.35 30-JUN-18:03 0.00 0.00
July 0.998428E+11 133520.17 29-JUL-15:02 740.60 0.336437E+12 0.00 0.436280E+12 3.23 4.26 03-JUL-15:03 0.00 0.00
August 0.664656E+11 109925.51 11-AUG-18:03 725.21 0.219613E+12 0.00 0.286079E+12 3.12 4.07 10-AUG-15:03 0.00 0.00
September 0.120585E+11 52060.99 02-SEP-18:02 502.26 0.378533E+11 0.00 0.499118E+11 2.21 3.52 02-SEP-18:02 0.00 0.00
October 0.147705E+10 27273.61 03-OCT-15:03 168.43 0.470593E+10 0.00 0.618298E+10 0.72 3.19 01-OCT-22:00 0.00 0.00
November 21340983.23 8062.23 05-NOV-08:04 2.81 68001665.06 0.00 89342648.28 0.01 3.19 24-NOV-09:06 0.00 0.00
December 13006676.16 11080.54 24-DEC-19:04 1.29 41444933.73 0.00 54451609.89 0.01 3.19 16-DEC-09:06 0.00 0.00
                         
Annual Sum or Average 0.326864E+12     4216.65 0.107862E+13 0.00 0.140548E+13 1.54     0.00 0.00
Minimum of Months 13006676.16 7430.49   1.23 41444933.73 0.00 54451609.89 0.01 3.19   0.00 0.00
Maximum of Months 0.998428E+11 133520.17   740.60 0.336437E+12 0.00 0.436280E+12 3.23 4.35   0.00 0.00



Table of Contents

Report: BoilerReportMonthly

For: HEATSYS1 BOILER

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

BOILER HEATING ENERGY [J] BOILER GAS CONSUMPTION [] BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] BOILER HEATING RATE {Maximum} [W] BOILER HEATING RATE {TIMESTAMP} BOILER GAS CONSUMPTION RATE [] BOILER INLET TEMPERATURE [C] BOILER OUTLET TEMPERATURE [C] BOILER MASS FLOW RATE [kg/s] BOILER ANCILLARY ELECTRICITY RATE [W] BOILER PART LOAD RATIO [] BOILER PART LOAD RATIO {Maximum} [] BOILER PART LOAD RATIO {TIMESTAMP}
January 0.901053E+12 0.00 744.00 1068591.40 12-JAN-09:03 0.00 50.14 82.18 2.55 0.00 0.37 1.18 12-JAN-09:03
February 0.707004E+12 0.00 672.00 981931.47 27-FEB-09:03 0.00 50.38 82.07 2.25 0.00 0.32 1.09 27-FEB-09:03
March 0.404473E+12 0.00 744.00 862041.20 01-MAR-09:03 0.00 49.88 81.96 1.15 0.00 0.17 0.95 01-MAR-09:03
April 0.840460E+11 0.00 673.52 341909.32 03-APR-08:61 0.00 51.66 78.41 0.27 0.00 0.04 0.38 03-APR-08:61
May 0.244503E+11 0.00 456.15 127849.86 29-MAY-23:18 0.00 39.33 62.58 0.06 0.00 0.01 0.14 29-MAY-23:18
June 0.810622E+10 0.00 233.74 115294.75 07-JUN-03:18 0.00 34.21 48.56 0.02 0.00 0.00 0.13 07-JUN-03:18
July 0.735013E+10 0.00 222.17 111151.19 31-JUL-03:48 0.00 37.64 50.06 0.02 0.00 0.00 0.12 31-JUL-03:48
August 0.141868E+11 0.00 360.30 132312.67 20-AUG-08:02 0.00 39.00 57.87 0.04 0.00 0.01 0.15 20-AUG-08:02
September 0.480167E+11 0.00 646.84 246384.11 29-SEP-08:61 0.00 50.71 76.22 0.18 0.00 0.02 0.27 29-SEP-08:61
October 0.198958E+12 0.00 743.04 356639.74 22-OCT-08:61 0.00 53.89 81.27 0.63 0.00 0.08 0.40 22-OCT-08:61
November 0.825416E+12 0.00 720.00 938503.95 29-NOV-09:03 0.00 50.01 82.20 2.43 0.00 0.35 1.04 29-NOV-09:03
December 0.103857E+13 0.00 744.00 1000360.59 15-DEC-09:03 0.00 50.07 82.15 2.95 0.00 0.43 1.11 15-DEC-09:03
                           
Annual Sum or Average 0.426164E+13 0.00 6959.77     0.00 46.37 72.05 1.04 0.00 0.15    
Minimum of Months 0.735013E+10 0.00 222.17 111151.19   0.00 34.21 48.56 0.02 0.00 0.00 0.12  
Maximum of Months 0.103857E+13 0.00 744.00 1068591.40   0.00 53.89 82.20 2.95 0.00 0.43 1.18  



Table of Contents

Report: DXReportMonthly

For: VAV WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 10389.95 0.00 0.08 10389.95 0.00 0.00 0.00 0.00 34.63 19-JAN-06:20 34.63 19-JAN-06:20 0.00 0.00 0.00
February 12630076.55 0.00 7.20 12630076.55 0.00 0.00 0.00 0.00 3883.87 07-FEB-21:10 3883.87 07-FEB-21:10 0.00 0.00 0.00
March 55323215.14 0.00 23.95 55323215.14 0.00 0.00 0.00 0.00 15137.64 22-MAR-18:49 15137.64 22-MAR-18:49 0.00 0.00 0.00
April 0.612247E+09 0.00 103.73 0.612247E+09 0.00 0.00 0.00 0.00 20916.25 27-APR-22:36 20916.25 27-APR-22:36 0.00 0.00 0.00
May 0.330998E+11 0.00 277.89 0.330998E+11 0.00 0.00 0.00 0.00 150268.02 31-MAY-18:03 150268.02 31-MAY-18:03 0.00 0.00 0.00
June 0.128881E+12 0.00 470.38 0.127899E+12 0.00 0.00 0.00 0.00 239341.11 29-JUN-20:00 227744.19 21-JUN-20:10 0.00 0.00 0.00
July 0.163163E+12 0.00 510.41 0.161095E+12 0.00 0.00 0.00 0.00 254705.18 29-JUL-18:03 225309.23 11-JUL-19:10 0.00 0.00 0.00
August 0.955801E+11 0.00 403.81 0.954680E+11 0.00 0.00 0.00 0.00 221678.89 11-AUG-20:10 221678.89 11-AUG-20:10 0.00 0.00 0.00
September 0.426427E+10 0.00 164.43 0.426427E+10 0.00 0.00 0.00 0.00 56246.15 02-SEP-17:50 56246.15 02-SEP-17:50 0.00 0.00 0.00
October 0.215145E+09 0.00 82.16 0.215145E+09 0.00 0.00 0.00 0.00 32355.45 07-OCT-20:40 32355.45 07-OCT-20:40 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 01-NOV-00:05 0.00 0.00 0.00
December 767558.00 0.00 0.50 767558.00 0.00 0.00 0.00 0.00 652.83 24-DEC-06:40 652.83 24-DEC-06:40 0.00 0.00 0.00
                               
Annual Sum or Average 0.425884E+12 0.00 2044.55 0.422722E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00 0.00 0.00
Maximum of Months 0.163163E+12 0.00 510.41 0.161095E+12 0.00 0.00 0.00 0.00 254705.18   227744.19   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: FLR_3_DOAS COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 0.00 01-FEB-00:03 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 0.00 01-MAR-00:03 0.00 0.00 0.00
April 12777529.52 0.00 3.33 12777529.52 0.00 0.00 0.00 0.00 2561.18 22-APR-14:00 2561.18 22-APR-14:00 0.00 0.00 0.00
May 0.491070E+10 0.00 174.97 0.491070E+10 0.00 0.00 0.00 0.00 24999.69 31-MAY-16:00 24999.69 31-MAY-16:00 0.00 0.00 0.00
June 0.211800E+11 0.00 428.33 0.209782E+11 0.00 0.00 0.00 0.00 35079.14 30-JUN-11:00 31352.36 30-JUN-15:00 0.00 0.00 0.00
July 0.271142E+11 0.00 478.83 0.266102E+11 0.00 0.00 0.00 0.00 39281.29 03-JUL-15:00 31815.88 29-JUL-15:02 0.00 0.00 0.00
August 0.159136E+11 0.00 345.83 0.158183E+11 0.00 0.00 0.00 0.00 29129.45 11-AUG-18:02 29129.45 11-AUG-18:02 0.00 0.00 0.00
September 0.477581E+09 0.00 44.36 0.477581E+09 0.00 0.00 0.00 0.00 8431.64 07-SEP-16:00 8431.64 07-SEP-16:00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 0.00 01-OCT-00:10 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 01-NOV-00:05 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 01-DEC-00:02 0.00 0.00 0.00
                               
Annual Sum or Average 0.696088E+11 0.00 1475.66 0.688077E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00 0.00 0.00
Maximum of Months 0.271142E+11 0.00 478.83 0.266102E+11 0.00 0.00 0.00 0.00 39281.29   31815.88   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_1_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 835052.91 0.00 0.43 835052.91 0.00 0.00 0.00 0.00 1653.52 22-JAN-09:04 1653.52 22-JAN-09:04 0.00 0.00 0.00
February 5620793.55 0.00 1.14 5620793.55 0.00 0.00 0.00 0.00 2543.83 11-FEB-19:04 2543.83 11-FEB-19:04 0.00 0.00 0.00
March 0.149968E+09 0.00 20.33 0.149968E+09 0.00 0.00 0.00 0.00 14508.22 22-MAR-15:02 14508.22 22-MAR-15:02 0.00 0.00 0.00
April 0.266479E+10 0.00 258.23 0.266479E+10 0.00 0.00 0.00 0.00 15228.80 30-APR-15:02 15228.80 30-APR-15:02 0.00 0.00 0.00
May 0.497982E+10 0.00 567.75 0.496830E+10 0.00 0.00 0.00 0.00 16081.95 31-MAY-18:02 16081.95 31-MAY-18:02 0.00 0.00 0.00
June 0.783000E+10 0.00 650.43 0.623750E+10 0.00 0.00 0.00 0.00 16453.32 13-JUN-15:02 16453.32 13-JUN-15:02 0.00 0.00 0.00
July 0.772311E+10 0.00 659.88 0.489012E+10 0.00 0.00 0.00 0.00 16297.12 26-JUL-15:02 15780.19 07-JUL-18:02 0.00 0.00 0.00
August 0.548435E+10 0.00 603.53 0.357947E+10 0.00 0.00 0.00 0.00 16270.36 10-AUG-18:02 16270.36 10-AUG-18:02 0.00 0.00 0.00
September 0.115939E+10 0.00 187.70 0.103894E+10 0.00 0.00 0.00 0.00 15389.21 02-SEP-18:02 15389.21 02-SEP-18:02 0.00 0.00 0.00
October 46503300.04 0.00 9.43 46503300.04 0.00 0.00 0.00 0.00 15231.87 03-OCT-15:01 15231.87 03-OCT-15:01 0.00 0.00 0.00
November 861891.61 0.00 0.45 861891.61 0.00 0.00 0.00 0.00 1071.89 01-NOV-15:04 1071.89 01-NOV-15:04 0.00 0.00 0.00
December 676886.25 0.00 0.29 676886.25 0.00 0.00 0.00 0.00 2126.16 24-DEC-09:04 2126.16 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.300459E+11 0.00 2959.56 0.235836E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 676886.25 0.00 0.29 676886.25 0.00 0.00 0.00 0.00 1071.89   1071.89   0.00 0.00 0.00
Maximum of Months 0.783000E+10 0.00 659.88 0.623750E+10 0.00 0.00 0.00 0.00 16453.32   16453.32   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_2_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 1160395.53 0.00 0.50 1160395.53 0.00 0.00 0.00 0.00 1914.45 22-JAN-09:04 1914.45 22-JAN-09:04 0.00 0.00 0.00
February 4495597.56 0.00 0.86 4495597.56 0.00 0.00 0.00 0.00 2921.53 09-FEB-16:04 2921.53 09-FEB-16:04 0.00 0.00 0.00
March 15372209.97 0.00 3.09 15372209.97 0.00 0.00 0.00 0.00 4538.03 20-MAR-15:03 4538.03 20-MAR-15:03 0.00 0.00 0.00
April 0.131473E+10 0.00 146.20 0.131473E+10 0.00 0.00 0.00 0.00 13592.89 30-APR-18:01 13592.89 30-APR-18:01 0.00 0.00 0.00
May 0.345305E+10 0.00 467.43 0.344540E+10 0.00 0.00 0.00 0.00 14355.38 31-MAY-18:02 14355.38 31-MAY-18:02 0.00 0.00 0.00
June 0.678843E+10 0.00 621.05 0.545222E+10 0.00 0.00 0.00 0.00 14686.60 13-JUN-15:02 14686.60 13-JUN-15:02 0.00 0.00 0.00
July 0.649482E+10 0.00 623.83 0.413124E+10 0.00 0.00 0.00 0.00 14531.03 26-JUL-15:02 14214.87 29-JUL-18:02 0.00 0.00 0.00
August 0.380422E+10 0.00 521.05 0.239281E+10 0.00 0.00 0.00 0.00 14560.53 03-AUG-15:02 14523.24 10-AUG-18:02 0.00 0.00 0.00
September 0.477110E+09 0.00 105.65 0.422394E+09 0.00 0.00 0.00 0.00 13736.57 02-SEP-18:02 13736.57 02-SEP-18:02 0.00 0.00 0.00
October 16998779.84 0.00 2.76 16998779.84 0.00 0.00 0.00 0.00 5598.45 04-OCT-18:03 5598.45 04-OCT-18:03 0.00 0.00 0.00
November 852305.11 0.00 0.36 852305.11 0.00 0.00 0.00 0.00 1151.03 04-NOV-08:04 1151.03 04-NOV-08:04 0.00 0.00 0.00
December 891469.05 0.00 0.26 891469.05 0.00 0.00 0.00 0.00 2409.32 24-DEC-09:04 2409.32 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.223721E+11 0.00 2493.05 0.171986E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 852305.11 0.00 0.26 852305.11 0.00 0.00 0.00 0.00 1151.03   1151.03   0.00 0.00 0.00
Maximum of Months 0.678843E+10 0.00 623.83 0.545222E+10 0.00 0.00 0.00 0.00 14686.60   14686.60   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 0.00 01-FEB-00:03 0.00 0.00 0.00
March 0.121275E+10 0.00 33.54 0.121275E+10 0.00 0.00 0.00 0.00 21663.62 29-MAR-14:30 21663.62 29-MAR-14:30 0.00 0.00 0.00
April 0.220677E+11 0.00 272.54 0.220677E+11 0.00 0.00 0.00 0.00 64515.83 22-APR-13:20 64515.83 22-APR-13:20 0.00 0.00 0.00
May 0.304516E+11 0.00 466.08 0.304516E+11 0.00 0.00 0.00 0.00 60207.34 12-MAY-13:20 60207.34 12-MAY-13:20 0.00 0.00 0.00
June 0.349707E+11 0.00 587.55 0.305177E+11 0.00 0.00 0.00 0.00 58334.07 30-JUN-12:30 52453.66 16-JUN-13:40 0.00 0.00 0.00
July 0.378253E+11 0.00 611.12 0.245944E+11 0.00 0.00 0.00 0.00 64743.91 23-JUL-13:30 58071.68 12-JUL-13:30 0.00 0.00 0.00
August 0.339423E+11 0.00 540.24 0.256484E+11 0.00 0.00 0.00 0.00 68415.92 25-AUG-13:30 63508.13 10-AUG-13:30 0.00 0.00 0.00
September 0.124307E+11 0.00 225.84 0.124307E+11 0.00 0.00 0.00 0.00 58718.87 09-SEP-13:10 58718.87 09-SEP-13:10 0.00 0.00 0.00
October 0.869594E+09 0.00 17.87 0.869594E+09 0.00 0.00 0.00 0.00 29725.74 03-OCT-12:55 29725.74 03-OCT-12:55 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 01-NOV-00:05 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 01-DEC-00:02 0.00 0.00 0.00
                               
Annual Sum or Average 0.173771E+12 0.00 2754.78 0.147793E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00 0.00 0.00
Maximum of Months 0.378253E+11 0.00 611.12 0.305177E+11 0.00 0.00 0.00 0.00 68415.92   64515.83   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 22257334.70 0.00 0.74 22257334.70 0.00 0.00 0.00 0.00 22705.78 16-JAN-09:04 22705.78 16-JAN-09:04 0.00 0.00 0.00
February 42923003.20 0.00 0.71 42923003.20 0.00 0.00 0.00 0.00 41394.64 10-FEB-19:04 41394.64 10-FEB-19:04 0.00 0.00 0.00
March 88869808.34 0.00 3.44 88869808.34 0.00 0.00 0.00 0.00 39076.95 10-MAR-19:04 39076.95 10-MAR-19:04 0.00 0.00 0.00
April 0.361338E+10 0.00 146.42 0.361338E+10 0.00 0.00 0.00 0.00 63309.47 30-APR-18:01 63309.47 30-APR-18:01 0.00 0.00 0.00
May 0.237146E+11 0.00 502.52 0.236544E+11 0.00 0.00 0.00 0.00 69730.58 31-MAY-18:02 69730.58 31-MAY-18:02 0.00 0.00 0.00
June 0.439852E+11 0.00 508.95 0.379408E+11 0.00 0.00 0.00 0.00 73622.64 22-JUN-18:02 73622.64 22-JUN-18:02 0.00 0.00 0.00
July 0.460262E+11 0.00 526.11 0.334648E+11 0.00 0.00 0.00 0.00 73979.01 13-JUL-18:02 73979.01 13-JUL-18:02 0.00 0.00 0.00
August 0.275036E+11 0.00 508.40 0.186816E+11 0.00 0.00 0.00 0.00 70559.92 11-AUG-15:02 70559.92 11-AUG-15:02 0.00 0.00 0.00
September 0.506412E+10 0.00 256.03 0.396714E+10 0.00 0.00 0.00 0.00 62300.05 10-SEP-18:02 62300.05 10-SEP-18:02 0.00 0.00 0.00
October 0.362716E+09 0.00 31.62 0.362716E+09 0.00 0.00 0.00 0.00 41482.36 07-OCT-08:62 41482.36 07-OCT-08:62 0.00 0.00 0.00
November 23172360.99 0.00 0.71 23172360.99 0.00 0.00 0.00 0.00 32011.63 05-NOV-08:04 32011.63 05-NOV-08:04 0.00 0.00 0.00
December 21082777.04 0.00 0.55 21082777.04 0.00 0.00 0.00 0.00 34597.52 24-DEC-19:04 34597.52 24-DEC-19:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.150468E+12 0.00 2486.21 0.121883E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 21082777.04 0.00 0.55 21082777.04 0.00 0.00 0.00 0.00 22705.78   22705.78   0.00 0.00 0.00
Maximum of Months 0.460262E+11 0.00 526.11 0.379408E+11 0.00 0.00 0.00 0.00 73979.01   73979.01   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_5_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 1109822.07 0.00 0.50 1109822.07 0.00 0.00 0.00 0.00 1846.97 22-JAN-09:04 1846.97 22-JAN-09:04 0.00 0.00 0.00
February 7397102.85 0.00 1.40 7397102.85 0.00 0.00 0.00 0.00 2754.74 10-FEB-19:04 2754.74 10-FEB-19:04 0.00 0.00 0.00
March 0.208639E+09 0.00 39.57 0.208639E+09 0.00 0.00 0.00 0.00 14037.60 22-MAR-15:02 14037.60 22-MAR-15:02 0.00 0.00 0.00
April 0.243515E+10 0.00 297.77 0.243515E+10 0.00 0.00 0.00 0.00 14319.78 28-APR-08:62 14319.78 28-APR-08:62 0.00 0.00 0.00
May 0.717769E+10 0.00 629.17 0.716828E+10 0.00 0.00 0.00 0.00 15115.40 31-MAY-18:02 15115.40 31-MAY-18:02 0.00 0.00 0.00
June 0.908307E+10 0.00 673.57 0.748815E+10 0.00 0.00 0.00 0.00 15365.67 22-JUN-18:02 15365.67 22-JUN-18:02 0.00 0.00 0.00
July 0.971902E+10 0.00 694.79 0.682431E+10 0.00 0.00 0.00 0.00 15265.50 26-JUL-15:02 15153.97 29-JUL-18:02 0.00 0.00 0.00
August 0.682301E+10 0.00 641.89 0.478675E+10 0.00 0.00 0.00 0.00 15292.78 10-AUG-18:02 15292.78 10-AUG-18:02 0.00 0.00 0.00
September 0.163548E+10 0.00 268.94 0.145340E+10 0.00 0.00 0.00 0.00 14393.33 07-SEP-15:02 14393.33 07-SEP-15:02 0.00 0.00 0.00
October 0.109892E+09 0.00 29.95 0.109892E+09 0.00 0.00 0.00 0.00 14288.95 03-OCT-15:01 14288.95 03-OCT-15:01 0.00 0.00 0.00
November 1013856.27 0.00 0.55 1013856.27 0.00 0.00 0.00 0.00 1030.26 04-NOV-08:04 1030.26 04-NOV-08:04 0.00 0.00 0.00
December 835768.88 0.00 0.29 835768.88 0.00 0.00 0.00 0.00 2288.88 24-DEC-09:04 2288.88 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.372023E+11 0.00 3278.39 0.304849E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 835768.88 0.00 0.29 835768.88 0.00 0.00 0.00 0.00 1030.26   1030.26   0.00 0.00 0.00
Maximum of Months 0.971902E+10 0.00 694.79 0.748815E+10 0.00 0.00 0.00 0.00 15365.67   15365.67   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_6_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 1335792.75 0.00 0.40 1335792.75 0.00 0.00 0.00 0.00 1666.96 22-JAN-09:04 1666.96 22-JAN-09:04 0.00 0.00 0.00
February 5294172.98 0.00 1.02 5294172.98 0.00 0.00 0.00 0.00 3017.11 09-FEB-19:04 3017.11 09-FEB-19:04 0.00 0.00 0.00
March 57371211.43 0.00 14.52 57371211.43 0.00 0.00 0.00 0.00 5089.07 10-MAR-09:03 5089.07 10-MAR-09:03 0.00 0.00 0.00
April 0.961823E+09 0.00 160.91 0.961823E+09 0.00 0.00 0.00 0.00 12865.87 28-APR-08:62 12865.87 28-APR-08:62 0.00 0.00 0.00
May 0.544065E+10 0.00 578.95 0.543412E+10 0.00 0.00 0.00 0.00 13581.01 31-MAY-18:02 13581.01 31-MAY-18:02 0.00 0.00 0.00
June 0.794952E+10 0.00 665.63 0.658651E+10 0.00 0.00 0.00 0.00 13805.57 22-JUN-18:02 13805.57 22-JUN-18:02 0.00 0.00 0.00
July 0.839012E+10 0.00 686.13 0.582789E+10 0.00 0.00 0.00 0.00 13890.54 13-JUL-18:02 13890.54 13-JUL-18:02 0.00 0.00 0.00
August 0.496463E+10 0.00 600.81 0.332733E+10 0.00 0.00 0.00 0.00 13757.84 03-AUG-15:02 13738.72 10-AUG-18:02 0.00 0.00 0.00
September 0.716234E+09 0.00 160.37 0.622020E+09 0.00 0.00 0.00 0.00 12872.35 09-SEP-08:62 12872.35 09-SEP-08:62 0.00 0.00 0.00
October 31693289.68 0.00 6.77 31693289.68 0.00 0.00 0.00 0.00 11321.76 04-OCT-08:61 11321.76 04-OCT-08:61 0.00 0.00 0.00
November 901989.21 0.00 0.38 901989.21 0.00 0.00 0.00 0.00 1333.23 04-NOV-08:04 1333.23 04-NOV-08:04 0.00 0.00 0.00
December 1002959.42 0.00 0.31 1002959.42 0.00 0.00 0.00 0.00 2563.43 24-DEC-09:04 2563.43 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.285206E+11 0.00 2876.20 0.228573E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 901989.21 0.00 0.31 901989.21 0.00 0.00 0.00 0.00 1333.23   1333.23   0.00 0.00 0.00
Maximum of Months 0.839012E+10 0.00 686.13 0.658651E+10 0.00 0.00 0.00 0.00 13890.54   13890.54   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_1_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 0.00 0.00
February 69791.87 0.00 0.19 69791.87 0.00 0.00 0.00 0.00 243.61 09-FEB-16:04 243.61 09-FEB-16:04 0.00 0.00 0.00
March 26109425.55 0.00 17.87 26109425.55 0.00 0.00 0.00 0.00 3724.27 22-MAR-15:02 3724.27 22-MAR-15:02 0.00 0.00 0.00
April 0.648124E+09 0.00 211.90 0.648124E+09 0.00 0.00 0.00 0.00 3966.85 30-APR-18:01 3966.85 30-APR-18:01 0.00 0.00 0.00
May 0.112432E+10 0.00 461.84 0.112236E+10 0.00 0.00 0.00 0.00 4189.13 31-MAY-18:02 4189.13 31-MAY-18:02 0.00 0.00 0.00
June 0.186134E+10 0.00 625.18 0.148687E+10 0.00 0.00 0.00 0.00 4286.03 13-JUN-15:02 4286.03 13-JUN-15:02 0.00 0.00 0.00
July 0.183417E+10 0.00 636.34 0.117535E+10 0.00 0.00 0.00 0.00 4284.48 13-JUL-18:02 4284.48 13-JUL-18:02 0.00 0.00 0.00
August 0.124512E+10 0.00 538.86 0.840460E+09 0.00 0.00 0.00 0.00 4239.81 13-AUG-08:62 4238.16 10-AUG-18:02 0.00 0.00 0.00
September 0.246804E+09 0.00 138.13 0.227911E+09 0.00 0.00 0.00 0.00 4008.75 02-SEP-18:02 4008.75 02-SEP-18:02 0.00 0.00 0.00
October 6613907.03 0.00 6.50 6607442.95 0.00 0.00 0.00 0.00 3954.05 03-OCT-15:01 3954.05 03-OCT-15:01 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 01-NOV-00:05 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 01-DEC-00:02 0.00 0.00 0.00
                               
Annual Sum or Average 0.699267E+10 0.00 2636.81 0.553386E+10 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00 0.00 0.00
Maximum of Months 0.186134E+10 0.00 636.34 0.148687E+10 0.00 0.00 0.00 0.00 4286.03   4286.03   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_2_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 0.00 0.00
February 35519.84 0.00 0.10 35519.84 0.00 0.00 0.00 0.00 199.95 09-FEB-16:04 199.95 09-FEB-16:04 0.00 0.00 0.00
March 1742105.67 0.00 1.17 1742105.67 0.00 0.00 0.00 0.00 1466.01 20-MAR-15:03 1466.01 20-MAR-15:03 0.00 0.00 0.00
April 0.302715E+09 0.00 115.29 0.302715E+09 0.00 0.00 0.00 0.00 3500.75 30-APR-18:01 3500.75 30-APR-18:01 0.00 0.00 0.00
May 0.723627E+09 0.00 348.32 0.722540E+09 0.00 0.00 0.00 0.00 3697.03 31-MAY-18:02 3697.03 31-MAY-18:02 0.00 0.00 0.00
June 0.157032E+10 0.00 595.58 0.125208E+10 0.00 0.00 0.00 0.00 3782.42 13-JUN-15:02 3782.42 13-JUN-15:02 0.00 0.00 0.00
July 0.149362E+10 0.00 598.92 0.950234E+09 0.00 0.00 0.00 0.00 3781.13 13-JUL-18:02 3781.13 13-JUL-18:02 0.00 0.00 0.00
August 0.803736E+09 0.00 438.69 0.528545E+09 0.00 0.00 0.00 0.00 3754.92 03-AUG-15:02 3740.09 10-AUG-18:02 0.00 0.00 0.00
September 85310602.06 0.00 62.06 78724407.14 0.00 0.00 0.00 0.00 3537.68 02-SEP-18:02 3537.68 02-SEP-18:02 0.00 0.00 0.00
October 2191372.62 0.00 1.56 2173421.66 0.00 0.00 0.00 0.00 1873.61 02-OCT-15:03 1873.61 02-OCT-15:03 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 01-NOV-00:05 0.00 0.00 0.00
December 574.94 0.00 0.02 574.94 0.00 0.00 0.00 0.00 6.71 24-DEC-09:04 6.71 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.498330E+10 0.00 2161.71 0.383879E+10 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00 0.00 0.00
Maximum of Months 0.157032E+10 0.00 598.92 0.125208E+10 0.00 0.00 0.00 0.00 3782.42   3782.42   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 1656852.58 0.00 0.43 1656852.58 0.00 0.00 0.00 0.00 2218.37 22-JAN-09:04 2218.37 22-JAN-09:04 0.00 0.00 0.00
February 0.141852E+09 0.00 20.24 0.141852E+09 0.00 0.00 0.00 0.00 23613.76 15-FEB-16:01 23613.76 15-FEB-16:01 0.00 0.00 0.00
March 0.203473E+10 0.00 127.03 0.203473E+10 0.00 0.00 0.00 0.00 23688.01 22-MAR-15:02 23688.01 22-MAR-15:02 0.00 0.00 0.00
April 0.648031E+10 0.00 369.13 0.648031E+10 0.00 0.00 0.00 0.00 23697.07 30-APR-15:02 23697.07 30-APR-15:02 0.00 0.00 0.00
May 0.871220E+10 0.00 590.01 0.866997E+10 0.00 0.00 0.00 0.00 25017.16 31-MAY-18:02 25017.16 31-MAY-18:02 0.00 0.00 0.00
June 0.109604E+11 0.00 646.99 0.846765E+10 0.00 0.00 0.00 0.00 25429.54 22-JUN-18:02 25429.54 22-JUN-18:02 0.00 0.00 0.00
July 0.120262E+11 0.00 662.04 0.765976E+10 0.00 0.00 0.00 0.00 25584.97 13-JUL-18:02 25584.97 13-JUL-18:02 0.00 0.00 0.00
August 0.102720E+11 0.00 628.42 0.712828E+10 0.00 0.00 0.00 0.00 25308.67 10-AUG-18:02 25308.67 10-AUG-18:02 0.00 0.00 0.00
September 0.400769E+10 0.00 336.39 0.361010E+10 0.00 0.00 0.00 0.00 23940.32 02-SEP-18:02 23940.32 02-SEP-18:02 0.00 0.00 0.00
October 0.925303E+09 0.00 80.64 0.925042E+09 0.00 0.00 0.00 0.00 23701.22 03-OCT-15:01 23701.22 03-OCT-15:01 0.00 0.00 0.00
November 5963798.85 0.00 2.10 5963798.85 0.00 0.00 0.00 0.00 12189.39 08-NOV-16:01 12189.39 08-NOV-16:01 0.00 0.00 0.00
December 993946.49 0.00 0.21 993946.49 0.00 0.00 0.00 0.00 2726.89 24-DEC-09:04 2726.89 24-DEC-09:04 0.00 0.00 0.00
                               
Annual Sum or Average 0.555693E+11 0.00 3463.64 0.451263E+11 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 993946.49 0.00 0.21 993946.49 0.00 0.00 0.00 0.00 2218.37   2218.37   0.00 0.00 0.00
Maximum of Months 0.120262E+11 0.00 662.04 0.866997E+10 0.00 0.00 0.00 0.00 25584.97   25584.97   0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 208.78 138.61 70.17 119.48 1097.02 0.00 0.00 0.00
February 697.78 483.41 214.37 577.51 879.26 0.00 0.00 0.00
March 1183.30 799.24 384.05 1142.58 673.59 0.00 0.00 0.00
April 1452.44 902.97 549.47 1566.63 428.45 0.00 0.00 0.00
May 1202.77 625.06 577.71 1350.77 207.94 0.00 0.00 0.00
June 1094.14 448.14 646.00 1275.16 97.54 0.00 0.00 0.00
July 1051.72 456.35 595.37 1257.61 102.02 0.00 0.00 0.00
August 1092.85 602.53 490.32 1276.44 163.43 0.00 0.00 0.00
September 871.13 519.88 351.25 918.72 319.82 0.00 0.00 0.00
October 643.96 407.53 236.43 577.72 571.87 0.00 0.00 0.00
November 348.67 245.15 103.52 223.60 1021.69 0.00 0.00 0.00
December 61.65 43.35 18.30 10.95 1219.28 0.00 0.00 0.00
                 
Annual Sum or Average 825.55 471.98 353.57 858.89 563.66 0.00 0.00 0.00
Minimum of Months 61.65 43.35 18.30 10.95 97.54 0.00 0.00 0.00
Maximum of Months 1452.44 902.97 646.00 1566.63 1219.28 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CAFE_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 587.92 390.33 197.59 333.90 3080.07 0.00 0.00 0.00
February 1964.90 1361.25 603.64 1615.64 2469.57 0.00 0.00 0.00
March 3332.09 2250.62 1081.47 3196.16 1902.62 0.00 0.00 0.00
April 4089.98 2542.70 1547.28 4384.52 1239.62 0.00 0.00 0.00
May 3386.93 1760.14 1626.79 3765.58 627.33 0.00 0.00 0.00
June 3081.01 1261.93 1819.08 3547.92 304.90 0.00 0.00 0.00
July 2961.57 1285.05 1676.52 3500.21 318.06 0.00 0.00 0.00
August 3077.41 1696.70 1380.71 3561.48 499.99 0.00 0.00 0.00
September 2453.03 1463.94 989.09 2563.26 939.25 0.00 0.00 0.00
October 1813.35 1147.58 665.78 1612.46 1621.80 0.00 0.00 0.00
November 981.84 690.33 291.52 624.42 2866.62 0.00 0.00 0.00
December 173.61 122.08 51.54 30.42 3419.96 0.00 0.00 0.00
                 
Annual Sum or Average 2324.69 1329.07 995.63 2396.84 1603.36 0.00 0.00 0.00
Minimum of Months 173.61 122.08 51.54 30.42 304.90 0.00 0.00 0.00
Maximum of Months 4089.98 2542.70 1819.08 4384.52 3419.96 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: LOBBY_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 763.74 507.06 256.68 432.59 4163.34 0.00 0.00 0.00
February 2552.51 1768.34 784.17 2115.06 3332.08 0.00 0.00 0.00
March 4328.57 2923.68 1404.89 4211.92 2567.65 0.00 0.00 0.00
April 5313.12 3303.11 2010.01 5776.39 1682.02 0.00 0.00 0.00
May 4399.81 2286.52 2113.29 4947.33 868.37 0.00 0.00 0.00
June 4002.41 1639.32 2363.09 4654.97 426.66 0.00 0.00 0.00
July 3847.25 1669.35 2177.90 4586.95 447.69 0.00 0.00 0.00
August 3997.73 2204.11 1793.62 4665.36 699.49 0.00 0.00 0.00
September 3186.63 1901.75 1284.88 3353.53 1313.82 0.00 0.00 0.00
October 2355.65 1490.77 864.88 2107.75 2230.47 0.00 0.00 0.00
November 1275.47 896.77 378.70 811.81 3873.33 0.00 0.00 0.00
December 225.54 158.58 66.95 38.57 4612.28 0.00 0.00 0.00
                 
Annual Sum or Average 3019.91 1726.53 1293.37 3144.73 2179.29 0.00 0.00 0.00
Minimum of Months 225.54 158.58 66.95 38.57 426.66 0.00 0.00 0.00
Maximum of Months 5313.12 3303.11 2363.09 5776.39 4612.28 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 41.28 27.41 13.87 24.17 219.64 0.00 0.00 0.00
February 137.96 95.58 42.38 116.72 175.70 0.00 0.00 0.00
March 233.96 158.02 75.93 229.64 135.10 0.00 0.00 0.00
April 287.17 178.53 108.64 312.18 86.12 0.00 0.00 0.00
May 237.81 123.59 114.22 267.72 41.39 0.00 0.00 0.00
June 216.33 88.60 127.73 252.79 18.55 0.00 0.00 0.00
July 207.94 90.23 117.72 249.89 19.36 0.00 0.00 0.00
August 216.08 119.13 96.95 253.79 31.70 0.00 0.00 0.00
September 172.24 102.79 69.45 183.85 63.40 0.00 0.00 0.00
October 127.32 80.58 46.75 116.53 113.94 0.00 0.00 0.00
November 68.94 48.47 20.47 45.73 203.07 0.00 0.00 0.00
December 12.19 8.57 3.62 2.29 243.53 0.00 0.00 0.00
                 
Annual Sum or Average 163.23 93.32 69.91 171.42 112.32 0.00 0.00 0.00
Minimum of Months 12.19 8.57 3.62 2.29 18.55 0.00 0.00 0.00
Maximum of Months 287.17 178.53 127.73 312.18 243.53 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_1_FLR_3_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 8.60 1.51 7.09 0.00 453.04 0.00 0.00 0.00
February 51.12 17.95 33.17 10.56 384.77 0.00 0.00 0.00
March 153.29 66.28 87.01 87.04 278.70 0.00 0.00 0.00
April 362.42 187.92 174.50 342.26 156.08 0.00 0.00 0.00
May 351.53 160.09 191.44 358.59 70.99 0.00 0.00 0.00
June 385.09 164.10 220.99 431.65 31.97 0.00 0.00 0.00
July 321.80 121.38 200.41 366.35 34.24 0.00 0.00 0.00
August 265.55 112.77 152.78 284.42 57.00 0.00 0.00 0.00
September 159.86 66.61 93.25 132.88 121.03 0.00 0.00 0.00
October 62.86 18.93 43.92 23.38 242.81 0.00 0.00 0.00
November 25.50 9.45 16.05 2.80 427.86 0.00 0.00 0.00
December 2.26 0.24 2.02 0.00 477.35 0.00 0.00 0.00
                 
Annual Sum or Average 179.62 77.43 102.18 170.67 227.18 0.00 0.00 0.00
Minimum of Months 2.26 0.24 2.02 0.00 31.97 0.00 0.00 0.00
Maximum of Months 385.09 187.92 220.99 431.65 477.35 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_2_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 3.32 0.00 3.32 0.00 243.84 0.00 0.00 0.00
February 14.69 0.00 14.69 0.00 216.34 0.00 0.00 0.00
March 39.36 0.01 39.35 3.97 160.02 0.00 0.00 0.00
April 71.97 2.14 69.82 30.57 84.46 0.00 0.00 0.00
May 110.17 17.90 92.28 90.21 32.82 0.00 0.00 0.00
June 142.46 31.76 110.71 146.95 12.97 0.00 0.00 0.00
July 120.49 20.30 100.19 128.53 15.45 0.00 0.00 0.00
August 77.67 4.79 72.88 69.04 28.34 0.00 0.00 0.00
September 42.76 0.15 42.61 19.12 66.00 0.00 0.00 0.00
October 20.69 0.00 20.69 1.95 134.99 0.00 0.00 0.00
November 6.42 0.00 6.42 0.00 236.57 0.00 0.00 0.00
December 1.01 0.00 1.01 0.00 255.06 0.00 0.00 0.00
                 
Annual Sum or Average 54.45 6.45 48.00 41.11 123.41 0.00 0.00 0.00
Minimum of Months 1.01 0.00 1.01 0.00 12.97 0.00 0.00 0.00
Maximum of Months 142.46 31.76 110.71 146.95 255.06 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_2_FLR_3_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 8.60 1.51 7.09 0.00 453.09 0.00 0.00 0.00
February 51.12 17.95 33.17 11.10 384.11 0.00 0.00 0.00
March 153.29 66.28 87.01 90.17 276.13 0.00 0.00 0.00
April 362.42 187.92 174.50 349.41 153.82 0.00 0.00 0.00
May 351.53 160.09 191.44 362.85 69.69 0.00 0.00 0.00
June 385.09 164.10 220.99 433.96 30.68 0.00 0.00 0.00
July 321.80 121.38 200.41 368.83 33.32 0.00 0.00 0.00
August 265.55 112.77 152.78 288.23 56.00 0.00 0.00 0.00
September 159.86 66.61 93.25 136.88 119.14 0.00 0.00 0.00
October 62.86 18.93 43.92 24.87 241.33 0.00 0.00 0.00
November 25.50 9.45 16.05 2.96 427.70 0.00 0.00 0.00
December 2.26 0.24 2.02 0.00 477.33 0.00 0.00 0.00
                 
Annual Sum or Average 179.62 77.43 102.18 173.12 226.05 0.00 0.00 0.00
Minimum of Months 2.26 0.24 2.02 0.00 30.68 0.00 0.00 0.00
Maximum of Months 385.09 187.92 220.99 433.96 477.33 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 33.02 21.92 11.10 19.28 171.95 0.00 0.00 0.00
February 110.35 76.45 33.90 92.83 137.52 0.00 0.00 0.00
March 187.13 126.39 60.74 182.08 107.56 0.00 0.00 0.00
April 229.69 142.80 86.90 247.09 73.24 0.00 0.00 0.00
May 190.21 98.85 91.36 211.66 37.54 0.00 0.00 0.00
June 173.03 70.87 102.16 199.77 18.14 0.00 0.00 0.00
July 166.32 72.17 94.15 197.26 18.97 0.00 0.00 0.00
August 172.83 95.29 77.54 200.36 29.96 0.00 0.00 0.00
September 137.76 82.21 55.55 144.30 55.43 0.00 0.00 0.00
October 101.84 64.45 37.39 91.91 90.82 0.00 0.00 0.00
November 55.14 38.77 16.37 36.39 158.73 0.00 0.00 0.00
December 9.75 6.86 2.89 1.81 191.08 0.00 0.00 0.00
                 
Annual Sum or Average 130.55 74.64 55.91 135.51 90.69 0.00 0.00 0.00
Minimum of Months 9.75 6.86 2.89 1.81 18.14 0.00 0.00 0.00
Maximum of Months 229.69 142.80 102.16 247.09 191.08 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 2.66 0.00 2.66 0.00 200.22 0.00 0.00 0.00
February 11.76 0.00 11.76 0.00 178.03 0.00 0.00 0.00
March 31.49 0.01 31.49 2.83 131.49 0.00 0.00 0.00
April 57.58 1.71 55.87 25.51 67.51 0.00 0.00 0.00
May 88.15 14.32 73.83 75.02 25.77 0.00 0.00 0.00
June 113.99 25.41 88.58 121.68 9.83 0.00 0.00 0.00
July 96.40 16.24 80.16 106.39 11.76 0.00 0.00 0.00
August 62.15 3.83 58.32 57.76 21.97 0.00 0.00 0.00
September 34.21 0.12 34.09 15.21 53.72 0.00 0.00 0.00
October 16.55 0.00 16.55 1.32 111.94 0.00 0.00 0.00
November 5.14 0.00 5.14 0.00 194.50 0.00 0.00 0.00
December 0.81 0.00 0.81 0.00 209.30 0.00 0.00 0.00
                 
Annual Sum or Average 43.56 5.16 38.40 34.01 100.93 0.00 0.00 0.00
Minimum of Months 0.81 0.00 0.81 0.00 9.83 0.00 0.00 0.00
Maximum of Months 113.99 25.41 88.58 121.68 209.30 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_5_FLR_3_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 18.51 6.94 11.57 2.48 442.42 0.00 0.00 0.00
February 95.50 45.86 49.63 49.83 366.01 0.00 0.00 0.00
March 267.11 135.10 132.01 223.74 272.02 0.00 0.00 0.00
April 355.26 179.71 175.55 323.76 146.41 0.00 0.00 0.00
May 516.75 291.12 225.64 565.12 66.69 0.00 0.00 0.00
June 473.55 220.67 252.88 542.22 27.77 0.00 0.00 0.00
July 450.97 218.81 232.16 530.18 31.37 0.00 0.00 0.00
August 362.45 177.29 185.16 405.83 54.20 0.00 0.00 0.00
September 226.99 102.52 124.47 214.09 117.76 0.00 0.00 0.00
October 123.11 49.89 73.22 89.00 231.97 0.00 0.00 0.00
November 25.68 9.43 16.25 2.07 426.50 0.00 0.00 0.00
December 3.67 0.90 2.77 0.00 475.10 0.00 0.00 0.00
                 
Annual Sum or Average 244.21 120.37 123.84 247.03 220.79 0.00 0.00 0.00
Minimum of Months 3.67 0.90 2.77 0.00 27.77 0.00 0.00 0.00
Maximum of Months 516.75 291.12 252.88 565.12 475.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 41.28 27.41 13.87 24.09 219.70 0.00 0.00 0.00
February 137.96 95.58 42.38 116.08 175.91 0.00 0.00 0.00
March 233.96 158.02 75.93 226.96 135.70 0.00 0.00 0.00
April 287.17 178.53 108.64 310.75 85.61 0.00 0.00 0.00
May 237.81 123.59 114.22 265.30 40.88 0.00 0.00 0.00
June 216.33 88.60 127.73 251.52 17.62 0.00 0.00 0.00
July 207.94 90.23 117.72 248.22 18.90 0.00 0.00 0.00
August 216.08 119.13 96.95 252.27 31.65 0.00 0.00 0.00
September 172.24 102.79 69.45 182.17 63.73 0.00 0.00 0.00
October 127.32 80.58 46.75 115.29 114.35 0.00 0.00 0.00
November 68.94 48.47 20.47 45.68 203.06 0.00 0.00 0.00
December 12.19 8.57 3.62 2.29 243.55 0.00 0.00 0.00
                 
Annual Sum or Average 163.23 93.32 69.91 170.19 112.25 0.00 0.00 0.00
Minimum of Months 12.19 8.57 3.62 2.29 17.62 0.00 0.00 0.00
Maximum of Months 287.17 178.53 127.73 310.75 243.55 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_6_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 3.32 0.00 3.32 0.00 243.60 0.00 0.00 0.00
February 14.69 0.00 14.69 0.00 216.01 0.00 0.00 0.00
March 39.36 0.01 39.35 3.43 161.32 0.00 0.00 0.00
April 71.97 2.14 69.82 29.04 84.30 0.00 0.00 0.00
May 110.17 17.90 92.28 86.64 32.82 0.00 0.00 0.00
June 142.46 31.76 110.71 145.24 12.87 0.00 0.00 0.00
July 120.49 20.30 100.19 126.30 15.44 0.00 0.00 0.00
August 77.67 4.79 72.88 66.89 28.50 0.00 0.00 0.00
September 42.76 0.15 42.61 17.54 66.84 0.00 0.00 0.00
October 20.69 0.00 20.69 1.65 135.49 0.00 0.00 0.00
November 6.42 0.00 6.42 0.00 236.61 0.00 0.00 0.00
December 1.01 0.00 1.01 0.00 255.03 0.00 0.00 0.00
                 
Annual Sum or Average 54.45 6.45 48.00 39.96 123.58 0.00 0.00 0.00
Minimum of Months 1.01 0.00 1.01 0.00 12.87 0.00 0.00 0.00
Maximum of Months 142.46 31.76 110.71 145.24 255.03 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_6_FLR_3_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 18.51 6.94 11.57 2.54 441.92 0.00 0.00 0.00
February 95.50 45.86 49.63 50.60 364.25 0.00 0.00 0.00
March 267.11 135.10 132.01 226.69 267.46 0.00 0.00 0.00
April 355.26 179.71 175.55 329.54 143.40 0.00 0.00 0.00
May 516.75 291.12 225.64 568.12 65.87 0.00 0.00 0.00
June 473.55 220.67 252.88 544.06 27.35 0.00 0.00 0.00
July 450.97 218.81 232.16 532.12 30.94 0.00 0.00 0.00
August 362.45 177.29 185.16 408.76 53.33 0.00 0.00 0.00
September 226.99 102.52 124.47 217.06 115.60 0.00 0.00 0.00
October 123.11 49.89 73.22 90.54 229.62 0.00 0.00 0.00
November 25.68 9.43 16.25 2.13 426.24 0.00 0.00 0.00
December 3.67 0.90 2.77 0.00 474.93 0.00 0.00 0.00
                 
Annual Sum or Average 244.21 120.37 123.84 249.02 219.35 0.00 0.00 0.00
Minimum of Months 3.67 0.90 2.77 0.00 27.35 0.00 0.00 0.00
Maximum of Months 516.75 291.12 252.88 568.12 474.93 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 4.21 0.00 4.21 0.00 324.85 0.00 0.00 0.00
February 18.61 0.00 18.61 0.00 290.03 0.00 0.00 0.00
March 49.85 0.01 49.84 3.77 215.37 0.00 0.00 0.00
April 91.14 2.71 88.43 36.34 112.73 0.00 0.00 0.00
May 139.53 22.67 116.86 110.70 46.11 0.00 0.00 0.00
June 180.42 40.22 140.20 181.64 19.80 0.00 0.00 0.00
July 152.59 25.71 126.88 158.36 23.63 0.00 0.00 0.00
August 98.37 6.06 92.30 83.78 41.48 0.00 0.00 0.00
September 54.15 0.19 53.96 21.53 90.99 0.00 0.00 0.00
October 26.20 0.00 26.20 1.78 183.14 0.00 0.00 0.00
November 8.13 0.00 8.13 0.00 315.84 0.00 0.00 0.00
December 1.28 0.00 1.28 0.00 339.20 0.00 0.00 0.00
                 
Annual Sum or Average 68.96 8.17 60.79 50.12 166.27 0.00 0.00 0.00
Minimum of Months 1.28 0.00 1.28 0.00 19.80 0.00 0.00 0.00
Maximum of Months 180.42 40.22 140.20 181.64 339.20 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 1.55 0.00 1.55 0.00 119.74 0.00 0.00 0.00
February 6.86 0.00 6.86 0.00 106.92 0.00 0.00 0.00
March 18.38 0.00 18.37 1.39 79.40 0.00 0.00 0.00
April 33.60 1.00 32.60 13.40 41.56 0.00 0.00 0.00
May 51.44 8.36 43.08 40.81 17.00 0.00 0.00 0.00
June 66.51 14.83 51.69 66.96 7.30 0.00 0.00 0.00
July 56.25 9.48 46.77 58.38 8.71 0.00 0.00 0.00
August 36.26 2.24 34.03 30.88 15.29 0.00 0.00 0.00
September 19.96 0.07 19.89 7.94 33.54 0.00 0.00 0.00
October 9.66 0.00 9.66 0.66 67.51 0.00 0.00 0.00
November 3.00 0.00 3.00 0.00 116.42 0.00 0.00 0.00
December 0.47 0.00 0.47 0.00 125.00 0.00 0.00 0.00
                 
Annual Sum or Average 25.42 3.01 22.41 18.48 61.29 0.00 0.00 0.00
Minimum of Months 0.47 0.00 0.47 0.00 7.30 0.00 0.00 0.00
Maximum of Months 66.51 14.83 51.69 66.96 125.00 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 19.26 12.79 6.47 10.77 107.66 0.00 0.00 0.00
February 64.37 44.60 19.78 53.28 85.71 0.00 0.00 0.00
March 109.16 73.73 35.43 106.32 65.36 0.00 0.00 0.00
April 133.99 83.30 50.69 146.47 41.54 0.00 0.00 0.00
May 110.96 57.66 53.30 125.03 21.41 0.00 0.00 0.00
June 100.94 41.34 59.60 117.30 10.60 0.00 0.00 0.00
July 97.03 42.10 54.93 115.90 11.01 0.00 0.00 0.00
August 100.82 55.59 45.23 118.28 16.95 0.00 0.00 0.00
September 80.37 47.96 32.40 85.64 31.45 0.00 0.00 0.00
October 59.41 37.60 21.81 53.47 55.80 0.00 0.00 0.00
November 32.17 22.62 9.55 20.44 99.23 0.00 0.00 0.00
December 5.69 4.00 1.69 0.95 119.44 0.00 0.00 0.00
                 
Annual Sum or Average 76.16 43.54 32.62 79.56 55.37 0.00 0.00 0.00
Minimum of Months 5.69 4.00 1.69 0.95 10.60 0.00 0.00 0.00
Maximum of Months 133.99 83.30 59.60 146.47 119.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 52.28 34.71 17.57 29.24 292.22 0.00 0.00 0.00
February 174.72 121.04 53.68 144.62 232.64 0.00 0.00 0.00
March 296.29 200.13 96.17 288.59 177.39 0.00 0.00 0.00
April 363.69 226.10 137.59 397.54 112.74 0.00 0.00 0.00
May 301.17 156.51 144.66 339.37 58.11 0.00 0.00 0.00
June 273.97 112.21 161.76 318.38 28.77 0.00 0.00 0.00
July 263.35 114.27 149.08 314.59 29.88 0.00 0.00 0.00
August 273.65 150.87 122.78 321.03 46.01 0.00 0.00 0.00
September 218.13 130.18 87.95 232.44 85.37 0.00 0.00 0.00
October 161.25 102.04 59.20 145.12 151.44 0.00 0.00 0.00
November 87.31 61.38 25.92 55.47 269.32 0.00 0.00 0.00
December 15.44 10.86 4.58 2.57 324.18 0.00 0.00 0.00
                 
Annual Sum or Average 206.72 118.18 88.53 215.95 150.29 0.00 0.00 0.00
Minimum of Months 15.44 10.86 4.58 2.57 28.77 0.00 0.00 0.00
Maximum of Months 363.69 226.10 161.76 397.54 324.18 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 41.28 27.41 13.87 24.28 218.31 0.00 0.00 0.00
February 137.96 95.58 42.38 117.05 174.59 0.00 0.00 0.00
March 233.96 158.02 75.93 229.80 134.54 0.00 0.00 0.00
April 287.17 178.53 108.64 311.66 85.77 0.00 0.00 0.00
May 237.81 123.59 114.22 266.99 40.94 0.00 0.00 0.00
June 216.33 88.60 127.73 251.89 18.23 0.00 0.00 0.00
July 207.94 90.23 117.72 249.11 19.02 0.00 0.00 0.00
August 216.08 119.13 96.95 253.29 31.22 0.00 0.00 0.00
September 172.24 102.79 69.45 184.10 62.58 0.00 0.00 0.00
October 127.32 80.58 46.75 116.78 113.23 0.00 0.00 0.00
November 68.94 48.47 20.47 46.08 201.19 0.00 0.00 0.00
December 12.19 8.57 3.62 2.33 242.06 0.00 0.00 0.00
                 
Annual Sum or Average 163.23 93.32 69.91 171.26 111.51 0.00 0.00 0.00
Minimum of Months 12.19 8.57 3.62 2.33 18.23 0.00 0.00 0.00
Maximum of Months 287.17 178.53 127.73 311.66 242.06 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_1_FLR_6_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 8.60 1.51 7.09 0.00 450.33 0.00 0.00 0.00
February 51.12 17.95 33.17 10.70 382.17 0.00 0.00 0.00
March 153.29 66.28 87.01 87.30 277.21 0.00 0.00 0.00
April 362.42 187.92 174.50 341.27 155.27 0.00 0.00 0.00
May 351.53 160.09 191.44 357.70 70.14 0.00 0.00 0.00
June 385.09 164.10 220.99 430.19 31.38 0.00 0.00 0.00
July 321.80 121.38 200.41 365.18 33.59 0.00 0.00 0.00
August 265.55 112.77 152.78 283.77 56.04 0.00 0.00 0.00
September 159.86 66.61 93.25 133.45 119.23 0.00 0.00 0.00
October 62.86 18.93 43.92 23.79 241.17 0.00 0.00 0.00
November 25.50 9.45 16.05 2.90 423.73 0.00 0.00 0.00
December 2.26 0.24 2.02 0.00 474.50 0.00 0.00 0.00
                 
Annual Sum or Average 179.62 77.43 102.18 170.37 225.43 0.00 0.00 0.00
Minimum of Months 2.26 0.24 2.02 0.00 31.38 0.00 0.00 0.00
Maximum of Months 385.09 187.92 220.99 430.19 474.50 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_2_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 3.32 0.00 3.32 0.00 242.51 0.00 0.00 0.00
February 14.69 0.00 14.69 0.00 215.05 0.00 0.00 0.00
March 39.36 0.01 39.35 4.07 159.35 0.00 0.00 0.00
April 71.97 2.14 69.82 30.93 84.10 0.00 0.00 0.00
May 110.17 17.90 92.28 90.49 32.45 0.00 0.00 0.00
June 142.46 31.76 110.71 146.71 12.75 0.00 0.00 0.00
July 120.49 20.30 100.19 128.35 15.18 0.00 0.00 0.00
August 77.67 4.79 72.88 69.32 27.84 0.00 0.00 0.00
September 42.76 0.15 42.61 19.75 64.89 0.00 0.00 0.00
October 20.69 0.00 20.69 2.12 134.17 0.00 0.00 0.00
November 6.42 0.00 6.42 0.00 234.45 0.00 0.00 0.00
December 1.01 0.00 1.01 0.00 253.57 0.00 0.00 0.00
                 
Annual Sum or Average 54.45 6.45 48.00 41.22 122.53 0.00 0.00 0.00
Minimum of Months 1.01 0.00 1.01 0.00 12.75 0.00 0.00 0.00
Maximum of Months 142.46 31.76 110.71 146.71 253.57 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_2_FLR_6_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 8.60 1.51 7.09 0.00 450.42 0.00 0.00 0.00
February 51.12 17.95 33.17 11.23 381.65 0.00 0.00 0.00
March 153.29 66.28 87.01 90.31 274.97 0.00 0.00 0.00
April 362.42 187.92 174.50 348.98 152.92 0.00 0.00 0.00
May 351.53 160.09 191.44 362.52 68.67 0.00 0.00 0.00
June 385.09 164.10 220.99 432.70 30.04 0.00 0.00 0.00
July 321.80 121.38 200.41 367.85 32.63 0.00 0.00 0.00
August 265.55 112.77 152.78 288.01 54.89 0.00 0.00 0.00
September 159.86 66.61 93.25 137.91 117.16 0.00 0.00 0.00
October 62.86 18.93 43.92 25.28 239.83 0.00 0.00 0.00
November 25.50 9.45 16.05 3.06 423.61 0.00 0.00 0.00
December 2.26 0.24 2.02 0.00 474.48 0.00 0.00 0.00
                 
Annual Sum or Average 179.62 77.43 102.18 173.00 224.30 0.00 0.00 0.00
Minimum of Months 2.26 0.24 2.02 0.00 30.04 0.00 0.00 0.00
Maximum of Months 385.09 187.92 220.99 432.70 474.48 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 60.54 40.19 20.35 34.53 325.47 0.00 0.00 0.00
February 202.34 140.17 62.16 166.44 261.91 0.00 0.00 0.00
March 343.12 231.76 111.37 328.35 202.83 0.00 0.00 0.00
April 421.17 261.84 159.33 451.65 127.75 0.00 0.00 0.00
May 348.77 181.25 167.52 389.76 60.28 0.00 0.00 0.00
June 317.27 129.95 187.32 369.96 26.43 0.00 0.00 0.00
July 304.97 132.33 172.64 365.21 27.77 0.00 0.00 0.00
August 316.90 174.72 142.18 369.67 46.16 0.00 0.00 0.00
September 252.60 150.75 101.85 265.34 94.61 0.00 0.00 0.00
October 186.73 118.17 68.56 165.83 170.99 0.00 0.00 0.00
November 101.11 71.09 30.02 65.46 300.15 0.00 0.00 0.00
December 17.88 12.57 5.31 3.25 360.38 0.00 0.00 0.00
                 
Annual Sum or Average 239.39 136.86 102.53 248.18 166.61 0.00 0.00 0.00
Minimum of Months 17.88 12.57 5.31 3.25 26.43 0.00 0.00 0.00
Maximum of Months 421.17 261.84 187.32 451.65 360.38 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: BANQUET_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 23.27 0.00 23.27 0.00 1812.91 0.00 0.00 0.00
February 102.86 0.00 102.86 0.00 1626.17 0.00 0.00 0.00
March 275.53 0.05 275.47 16.43 1239.57 0.00 0.00 0.00
April 503.74 15.00 488.74 182.01 665.24 0.00 0.00 0.00
May 771.18 125.28 645.90 586.34 262.43 0.00 0.00 0.00
June 997.21 222.29 774.92 991.19 109.89 0.00 0.00 0.00
July 843.38 142.08 701.30 862.99 130.95 0.00 0.00 0.00
August 543.68 33.51 510.17 446.99 234.23 0.00 0.00 0.00
September 299.28 1.05 298.24 103.92 545.07 0.00 0.00 0.00
October 144.80 0.00 144.80 6.18 1081.62 0.00 0.00 0.00
November 44.94 0.00 44.94 0.00 1756.75 0.00 0.00 0.00
December 7.06 0.00 7.06 0.00 1882.34 0.00 0.00 0.00
                 
Annual Sum or Average 381.13 45.15 335.98 267.95 941.94 0.00 0.00 0.00
Minimum of Months 7.06 0.00 7.06 0.00 109.89 0.00 0.00 0.00
Maximum of Months 997.21 222.29 774.92 991.19 1882.34 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: DINING_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 23.27 0.00 23.27 0.00 1842.11 0.00 0.00 0.00
February 102.86 0.00 102.86 0.00 1654.83 0.00 0.00 0.00
March 275.53 0.05 275.47 14.35 1265.11 0.00 0.00 0.00
April 503.74 15.00 488.74 173.79 679.04 0.00 0.00 0.00
May 771.18 125.28 645.90 575.87 267.18 0.00 0.00 0.00
June 997.21 222.29 774.92 982.65 112.39 0.00 0.00 0.00
July 843.38 142.08 701.30 855.04 133.96 0.00 0.00 0.00
August 543.68 33.51 510.17 438.86 239.51 0.00 0.00 0.00
September 299.28 1.05 298.24 97.95 559.25 0.00 0.00 0.00
October 144.80 0.00 144.80 4.99 1107.26 0.00 0.00 0.00
November 44.94 0.00 44.94 0.00 1786.36 0.00 0.00 0.00
December 7.06 0.00 7.06 0.00 1910.78 0.00 0.00 0.00
                 
Annual Sum or Average 381.13 45.15 335.98 263.54 959.42 0.00 0.00 0.00
Minimum of Months 7.06 0.00 7.06 0.00 112.39 0.00 0.00 0.00
Maximum of Months 997.21 222.29 774.92 982.65 1910.78 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: KITCHEN_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 3.32 0.00 3.32 0.00 219.47 0.00 0.00 0.00
February 14.69 0.00 14.69 0.00 193.39 0.00 0.00 0.00
March 39.36 0.01 39.35 7.50 144.63 0.00 0.00 0.00
April 71.97 2.14 69.82 48.11 80.06 0.00 0.00 0.00
May 110.17 17.90 92.28 118.70 34.30 0.00 0.00 0.00
June 142.46 31.76 110.71 182.44 15.05 0.00 0.00 0.00
July 120.49 20.30 100.19 163.72 17.38 0.00 0.00 0.00
August 77.67 4.79 72.88 99.86 28.74 0.00 0.00 0.00
September 42.76 0.15 42.61 34.88 58.54 0.00 0.00 0.00
October 20.69 0.00 20.69 4.71 119.56 0.00 0.00 0.00
November 6.42 0.00 6.42 0.00 211.44 0.00 0.00 0.00
December 1.01 0.00 1.01 0.00 230.08 0.00 0.00 0.00
                 
Annual Sum or Average 54.45 6.45 48.00 55.32 112.29 0.00 0.00 0.00
Minimum of Months 1.01 0.00 1.01 0.00 15.05 0.00 0.00 0.00
Maximum of Months 142.46 31.76 110.71 182.44 230.08 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: KITCHEN_FLR_6_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 37.02 13.87 23.15 7.68 797.47 0.00 0.00 0.00
February 190.98 91.72 99.26 118.74 660.65 0.00 0.00 0.00
March 534.18 270.18 264.00 494.22 494.20 0.00 0.00 0.00
April 710.48 359.40 351.08 744.51 281.16 0.00 0.00 0.00
May 1033.44 582.19 451.25 1254.15 133.40 0.00 0.00 0.00
June 947.02 441.31 505.72 1225.02 60.49 0.00 0.00 0.00
July 901.87 437.59 464.28 1202.60 67.40 0.00 0.00 0.00
August 724.85 354.55 370.30 942.74 107.57 0.00 0.00 0.00
September 453.95 205.03 248.92 514.08 212.52 0.00 0.00 0.00
October 246.20 99.77 146.43 211.67 416.67 0.00 0.00 0.00
November 51.36 18.86 32.49 7.22 761.67 0.00 0.00 0.00
December 7.34 1.80 5.54 0.00 858.43 0.00 0.00 0.00
                 
Annual Sum or Average 488.39 240.72 247.67 563.16 403.02 0.00 0.00 0.00
Minimum of Months 7.34 1.80 5.54 0.00 60.49 0.00 0.00 0.00
Maximum of Months 1033.44 582.19 505.72 1254.15 858.43 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 41.28 27.41 13.87 27.60 198.57 0.00 0.00 0.00
February 137.96 95.58 42.38 125.72 160.45 0.00 0.00 0.00
March 233.96 158.02 75.93 244.63 126.33 0.00 0.00 0.00
April 287.17 178.53 108.64 336.73 81.08 0.00 0.00 0.00
May 237.81 123.59 114.22 298.19 40.44 0.00 0.00 0.00
June 216.33 88.60 127.73 289.47 19.96 0.00 0.00 0.00
July 207.94 90.23 117.72 286.41 20.66 0.00 0.00 0.00
August 216.08 119.13 96.95 286.19 30.48 0.00 0.00 0.00
September 172.24 102.79 69.45 205.96 57.66 0.00 0.00 0.00
October 127.32 80.58 46.75 128.22 104.73 0.00 0.00 0.00
November 68.94 48.47 20.47 51.34 182.80 0.00 0.00 0.00
December 12.19 8.57 3.62 3.20 219.56 0.00 0.00 0.00
                 
Annual Sum or Average 163.23 93.32 69.91 190.50 103.29 0.00 0.00 0.00
Minimum of Months 12.19 8.57 3.62 3.20 19.96 0.00 0.00 0.00
Maximum of Months 287.17 178.53 127.73 336.73 219.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 4.21 0.00 4.21 0.00 324.70 0.00 0.00 0.00
February 18.61 0.00 18.61 0.00 290.44 0.00 0.00 0.00
March 49.85 0.01 49.84 3.43 217.47 0.00 0.00 0.00
April 91.14 2.71 88.43 34.43 113.51 0.00 0.00 0.00
May 139.53 22.67 116.86 108.55 45.97 0.00 0.00 0.00
June 180.42 40.22 140.20 178.11 20.13 0.00 0.00 0.00
July 152.59 25.71 126.88 154.91 24.12 0.00 0.00 0.00
August 98.37 6.06 92.30 81.33 41.80 0.00 0.00 0.00
September 54.15 0.19 53.96 20.59 91.52 0.00 0.00 0.00
October 26.20 0.00 26.20 1.55 185.51 0.00 0.00 0.00
November 8.13 0.00 8.13 0.00 314.68 0.00 0.00 0.00
December 1.28 0.00 1.28 0.00 338.58 0.00 0.00 0.00
                 
Annual Sum or Average 68.96 8.17 60.79 48.87 166.71 0.00 0.00 0.00
Minimum of Months 1.28 0.00 1.28 0.00 20.13 0.00 0.00 0.00
Maximum of Months 180.42 40.22 140.20 178.11 338.58 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 3.77 0.00 3.77 0.00 290.51 0.00 0.00 0.00
February 16.65 0.00 16.65 0.00 259.78 0.00 0.00 0.00
March 44.60 0.01 44.59 3.07 194.57 0.00 0.00 0.00
April 81.54 2.43 79.12 30.81 101.56 0.00 0.00 0.00
May 124.84 20.28 104.56 97.12 41.13 0.00 0.00 0.00
June 161.42 35.98 125.44 159.36 18.01 0.00 0.00 0.00
July 136.52 23.00 113.52 138.60 21.58 0.00 0.00 0.00
August 88.01 5.42 82.58 72.77 37.40 0.00 0.00 0.00
September 48.45 0.17 48.28 18.43 81.88 0.00 0.00 0.00
October 23.44 0.00 23.44 1.39 165.94 0.00 0.00 0.00
November 7.27 0.00 7.27 0.00 281.54 0.00 0.00 0.00
December 1.14 0.00 1.14 0.00 302.93 0.00 0.00 0.00
                 
Annual Sum or Average 61.70 7.31 54.39 43.72 149.15 0.00 0.00 0.00
Minimum of Months 1.14 0.00 1.14 0.00 18.01 0.00 0.00 0.00
Maximum of Months 161.42 35.98 125.44 159.36 302.93 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 154.11 102.32 51.79 85.91 861.29 0.00 0.00 0.00
February 515.06 356.82 158.23 424.83 686.32 0.00 0.00 0.00
March 873.44 589.95 283.49 844.79 526.24 0.00 0.00 0.00
April 1072.10 666.52 405.59 1162.45 333.32 0.00 0.00 0.00
May 887.81 461.38 426.43 991.92 170.55 0.00 0.00 0.00
June 807.63 330.79 476.84 927.11 86.53 0.00 0.00 0.00
July 776.32 336.85 439.47 916.07 90.13 0.00 0.00 0.00
August 806.68 444.75 361.93 937.49 136.96 0.00 0.00 0.00
September 643.01 383.74 259.27 679.93 252.52 0.00 0.00 0.00
October 475.33 300.81 174.52 423.56 451.23 0.00 0.00 0.00
November 257.37 180.95 76.42 163.56 791.18 0.00 0.00 0.00
December 45.51 32.00 13.51 7.60 954.56 0.00 0.00 0.00
                 
Annual Sum or Average 609.37 348.39 260.98 631.00 443.95 0.00 0.00 0.00
Minimum of Months 45.51 32.00 13.51 7.60 86.53 0.00 0.00 0.00
Maximum of Months 1072.10 666.52 476.84 1162.45 954.56 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.559203E+09 0.371266E+09 0.187937E+09 0.320012E+09 0.293825E+10
February 0.168806E+10 0.116947E+10 0.518598E+09 0.139712E+10 0.212711E+10
March 0.316934E+10 0.214069E+10 0.102865E+10 0.306028E+10 0.180415E+10
April 0.376473E+10 0.234050E+10 0.142424E+10 0.406070E+10 0.111054E+10
May 0.322150E+10 0.167417E+10 0.154734E+10 0.361792E+10 0.556942E+09
June 0.283600E+10 0.116157E+10 0.167442E+10 0.330520E+10 0.252833E+09
July 0.281692E+10 0.122228E+10 0.159464E+10 0.336837E+10 0.273248E+09
August 0.292710E+10 0.161383E+10 0.131327E+10 0.341882E+10 0.437734E+09
September 0.225796E+10 0.134752E+10 0.910433E+09 0.238131E+10 0.828978E+09
October 0.172479E+10 0.109153E+10 0.633259E+09 0.154736E+10 0.153170E+10
November 0.903765E+09 0.635430E+09 0.268335E+09 0.579560E+09 0.264822E+10
December 0.165135E+09 0.116113E+09 49022045.21 29331857.35 0.326573E+10
           
Annual Sum or Average 0.260345E+11 0.148844E+11 0.111501E+11 0.270860E+11 0.177754E+11
Minimum of Months 0.165135E+09 0.116113E+09 49022045.21 29331857.35 0.252833E+09
Maximum of Months 0.376473E+10 0.234050E+10 0.167442E+10 0.406070E+10 0.326573E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: CAFE_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.157468E+10 0.104546E+10 0.529219E+09 0.894315E+09 0.824967E+10
February 0.475348E+10 0.329314E+10 0.146034E+10 0.390855E+10 0.597438E+10
March 0.892466E+10 0.602805E+10 0.289661E+10 0.856059E+10 0.509598E+10
April 0.106012E+11 0.659068E+10 0.401055E+10 0.113647E+11 0.321309E+10
May 0.907154E+10 0.471435E+10 0.435719E+10 0.100857E+11 0.168025E+10
June 0.798599E+10 0.327092E+10 0.471507E+10 0.919621E+10 0.790307E+09
July 0.793227E+10 0.344187E+10 0.449040E+10 0.937496E+10 0.851905E+09
August 0.824253E+10 0.454444E+10 0.369809E+10 0.953906E+10 0.133918E+10
September 0.635826E+10 0.379454E+10 0.256372E+10 0.664398E+10 0.243455E+10
October 0.485689E+10 0.307367E+10 0.178321E+10 0.431880E+10 0.434383E+10
November 0.254494E+10 0.178933E+10 0.755614E+09 0.161851E+10 0.743029E+10
December 0.465010E+09 0.326967E+09 0.138043E+09 81482475.74 0.916002E+10
           
Annual Sum or Average 0.733115E+11 0.419134E+11 0.313981E+11 0.755868E+11 0.505634E+11
Minimum of Months 0.465010E+09 0.326967E+09 0.138043E+09 81482475.74 0.790307E+09
Maximum of Months 0.106012E+11 0.659068E+10 0.471507E+10 0.113647E+11 0.916002E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: LOBBY_FLR_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.204560E+10 0.135811E+10 0.687486E+09 0.115864E+10 0.111511E+11
February 0.617504E+10 0.427797E+10 0.189706E+10 0.511675E+10 0.806096E+10
March 0.115936E+11 0.783078E+10 0.376286E+10 0.112812E+11 0.687721E+10
April 0.137716E+11 0.856167E+10 0.520994E+10 0.149724E+11 0.435979E+10
May 0.117845E+11 0.612421E+10 0.566024E+10 0.132509E+11 0.232583E+10
June 0.103742E+11 0.424911E+10 0.612514E+10 0.120657E+11 0.110591E+10
July 0.103045E+11 0.447118E+10 0.583329E+10 0.122857E+11 0.119908E+10
August 0.107075E+11 0.590348E+10 0.480403E+10 0.124957E+11 0.187352E+10
September 0.825974E+10 0.492932E+10 0.333042E+10 0.869235E+10 0.340541E+10
October 0.630937E+10 0.399287E+10 0.231650E+10 0.564541E+10 0.597408E+10
November 0.330602E+10 0.232444E+10 0.981585E+09 0.210422E+10 0.100397E+11
December 0.604074E+09 0.424749E+09 0.179326E+09 0.103304E+09 0.123535E+11
           
Annual Sum or Average 0.952358E+11 0.544479E+11 0.407879E+11 0.991723E+11 0.687261E+11
Minimum of Months 0.604074E+09 0.424749E+09 0.179326E+09 0.103304E+09 0.110591E+10
Maximum of Months 0.137716E+11 0.856167E+10 0.612514E+10 0.149724E+11 0.123535E+11



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.110564E+09 73405614.99 37158509.44 64746269.22 0.588294E+09
February 0.333759E+09 0.231223E+09 0.102536E+09 0.282360E+09 0.425063E+09
March 0.626634E+09 0.423252E+09 0.203383E+09 0.615055E+09 0.361848E+09
April 0.744354E+09 0.462756E+09 0.281598E+09 0.809167E+09 0.223230E+09
May 0.636949E+09 0.331012E+09 0.305937E+09 0.717059E+09 0.110868E+09
June 0.560728E+09 0.229663E+09 0.331065E+09 0.655236E+09 48074287.82
July 0.556956E+09 0.241666E+09 0.315290E+09 0.669316E+09 51844105.26
August 0.578740E+09 0.319082E+09 0.259658E+09 0.679746E+09 84910480.33
September 0.446438E+09 0.266429E+09 0.180009E+09 0.476535E+09 0.164330E+09
October 0.341020E+09 0.215814E+09 0.125207E+09 0.312124E+09 0.305178E+09
November 0.178690E+09 0.125635E+09 53054557.55 0.118527E+09 0.526360E+09
December 32650088.02 22957571.06 9692516.96 6144050.05 0.652272E+09
           
Annual Sum or Average 0.514748E+10 0.294290E+10 0.220459E+10 0.540602E+10 0.354227E+10
Minimum of Months 32650088.02 22957571.06 9692516.96 6144050.05 48074287.82
Maximum of Months 0.744354E+09 0.462756E+09 0.331065E+09 0.809167E+09 0.652272E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_1_FLR_3_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 23027276.62 4040088.38 18987188.23 0.00 0.121341E+10
February 0.123676E+09 43420979.82 80255376.49 25546077.31 0.930824E+09
March 0.410572E+09 0.177514E+09 0.233059E+09 0.233125E+09 0.746478E+09
April 0.939386E+09 0.487081E+09 0.452305E+09 0.887128E+09 0.404570E+09
May 0.941543E+09 0.428795E+09 0.512747E+09 0.960436E+09 0.190128E+09
June 0.998144E+09 0.425339E+09 0.572805E+09 0.111882E+10 82873289.19
July 0.861900E+09 0.325115E+09 0.536786E+09 0.981222E+09 91711165.19
August 0.711248E+09 0.302051E+09 0.409197E+09 0.761793E+09 0.152670E+09
September 0.414345E+09 0.172645E+09 0.241700E+09 0.344423E+09 0.313718E+09
October 0.168359E+09 50713878.96 0.117645E+09 62629097.61 0.650331E+09
November 66100104.82 24494500.61 41605604.21 7255393.45 0.110903E+10
December 6052526.62 646601.17 5405925.45 0.00 0.127854E+10
           
Annual Sum or Average 0.566435E+10 0.244186E+10 0.322250E+10 0.538238E+10 0.716429E+10
Minimum of Months 6052526.62 646601.17 5405925.45 0.00 82873289.19
Maximum of Months 0.998144E+09 0.487081E+09 0.572805E+09 0.111882E+10 0.127854E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_2_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 8903365.66 0.00 8903365.66 0.00 0.653104E+09
February 35548435.04 0.00 35548435.04 0.00 0.523361E+09
March 0.105429E+09 20769.03 0.105408E+09 10641483.89 0.428608E+09
April 0.186535E+09 5554766.90 0.180981E+09 79235086.13 0.218921E+09
May 0.295088E+09 47938100.07 0.247150E+09 0.241613E+09 87892889.70
June 0.369268E+09 82313943.57 0.286954E+09 0.380898E+09 33615216.37
July 0.322713E+09 54364303.60 0.268349E+09 0.344259E+09 41393314.43
August 0.208037E+09 12822498.21 0.195214E+09 0.184914E+09 75918907.02
September 0.110825E+09 387910.37 0.110437E+09 49550931.66 0.171077E+09
October 55405927.66 0.00 55405927.66 5227712.33 0.361569E+09
November 16639755.89 0.00 16639755.89 0.00 0.613198E+09
December 2700813.42 0.00 2700813.42 0.00 0.683146E+09
           
Annual Sum or Average 0.171709E+10 0.203402E+09 0.151369E+10 0.129634E+10 0.389180E+10
Minimum of Months 2700813.42 0.00 2700813.42 0.00 33615216.37
Maximum of Months 0.369268E+09 82313943.57 0.286954E+09 0.380898E+09 0.683146E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_2_FLR_3_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 23027276.62 4040088.38 18987188.23 0.00 0.121356E+10
February 0.123676E+09 43420979.82 80255376.49 26841606.33 0.929231E+09
March 0.410572E+09 0.177514E+09 0.233059E+09 0.241501E+09 0.739595E+09
April 0.939386E+09 0.487081E+09 0.452305E+09 0.905677E+09 0.398700E+09
May 0.941543E+09 0.428795E+09 0.512747E+09 0.971855E+09 0.186646E+09
June 0.998144E+09 0.425339E+09 0.572805E+09 0.112481E+10 79519890.27
July 0.861900E+09 0.325115E+09 0.536786E+09 0.987869E+09 89253445.31
August 0.711248E+09 0.302051E+09 0.409197E+09 0.772002E+09 0.150002E+09
September 0.414345E+09 0.172645E+09 0.241700E+09 0.354790E+09 0.308811E+09
October 0.168359E+09 50713878.96 0.117645E+09 66600048.14 0.646367E+09
November 66100104.82 24494500.61 41605604.21 7661472.21 0.110859E+10
December 6052526.62 646601.17 5405925.45 0.00 0.127847E+10
           
Annual Sum or Average 0.566435E+10 0.244186E+10 0.322250E+10 0.545961E+10 0.712874E+10
Minimum of Months 6052526.62 646601.17 5405925.45 0.00 79519890.27
Maximum of Months 0.998144E+09 0.487081E+09 0.572805E+09 0.112481E+10 0.127847E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 88433712.47 58712815.60 29720896.87 51648481.22 0.460559E+09
February 0.266954E+09 0.184942E+09 82012514.30 0.224581E+09 0.332686E+09
March 0.501208E+09 0.338534E+09 0.162674E+09 0.487695E+09 0.288102E+09
April 0.595365E+09 0.370131E+09 0.225234E+09 0.640456E+09 0.189850E+09
May 0.509458E+09 0.264757E+09 0.244701E+09 0.566918E+09 0.100534E+09
June 0.448493E+09 0.183694E+09 0.264799E+09 0.517800E+09 47026533.21
July 0.445476E+09 0.193294E+09 0.252182E+09 0.528330E+09 50803746.01
August 0.462900E+09 0.255215E+09 0.207685E+09 0.536654E+09 80252730.27
September 0.357079E+09 0.213101E+09 0.143979E+09 0.374026E+09 0.143664E+09
October 0.272762E+09 0.172617E+09 0.100145E+09 0.246175E+09 0.243265E+09
November 0.142924E+09 0.100488E+09 42435206.82 94313248.80 0.411418E+09
December 26114876.87 18362405.06 7752471.81 4847111.02 0.511788E+09
           
Annual Sum or Average 0.411717E+10 0.235385E+10 0.176332E+10 0.427344E+10 0.285995E+10
Minimum of Months 26114876.87 18362405.06 7752471.81 4847111.02 47026533.21
Maximum of Months 0.595365E+09 0.370131E+09 0.264799E+09 0.640456E+09 0.511788E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 7123636.68 0.00 7123636.68 0.00 0.536275E+09
February 28442517.75 0.00 28442517.75 0.00 0.430700E+09
March 84353997.24 16617.43 84337379.81 7569515.52 0.352189E+09
April 0.149248E+09 4444402.57 0.144804E+09 66131657.10 0.174998E+09
May 0.236102E+09 38355563.63 0.197746E+09 0.200940E+09 69014504.24
June 0.295454E+09 65859883.80 0.229594E+09 0.315400E+09 25469982.24
July 0.258205E+09 43497207.92 0.214707E+09 0.284967E+09 31495630.49
August 0.166451E+09 10259358.32 0.156192E+09 0.154711E+09 58855636.77
September 88671519.31 310369.43 88361149.88 39419964.43 0.139252E+09
October 44330617.62 0.00 44330617.62 3542928.45 0.299812E+09
November 13313569.27 0.00 13313569.27 0.00 0.504155E+09
December 2160937.14 0.00 2160937.14 0.00 0.560577E+09
           
Annual Sum or Average 0.137386E+10 0.162743E+09 0.121111E+10 0.107268E+10 0.318280E+10
Minimum of Months 2160937.14 0.00 2160937.14 0.00 25469982.24
Maximum of Months 0.295454E+09 65859883.80 0.229594E+09 0.315400E+09 0.560577E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_5_FLR_3_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 49579463.84 18581123.47 30998340.38 6639499.36 0.118498E+10
February 0.231022E+09 0.110948E+09 0.120073E+09 0.120549E+09 0.885463E+09
March 0.715425E+09 0.361845E+09 0.353579E+09 0.599266E+09 0.728573E+09
April 0.920846E+09 0.465817E+09 0.455029E+09 0.839192E+09 0.379482E+09
May 0.138407E+10 0.779723E+09 0.604352E+09 0.151362E+10 0.178622E+09
June 0.122743E+10 0.571977E+09 0.655454E+09 0.140544E+10 71984287.49
July 0.120787E+10 0.586057E+09 0.621808E+09 0.142004E+10 84015461.56
August 0.970784E+09 0.474845E+09 0.495938E+09 0.108698E+10 0.145177E+09
September 0.588361E+09 0.265743E+09 0.322618E+09 0.554922E+09 0.305232E+09
October 0.329733E+09 0.133619E+09 0.196115E+09 0.238382E+09 0.621310E+09
November 66562843.98 24447723.86 42115120.13 5354471.57 0.110548E+10
December 9834683.28 2409699.07 7424984.20 0.00 0.127252E+10
           
Annual Sum or Average 0.770152E+10 0.379601E+10 0.390551E+10 0.779038E+10 0.696284E+10
Minimum of Months 9834683.28 2409699.07 7424984.20 0.00 71984287.49
Maximum of Months 0.138407E+10 0.779723E+09 0.655454E+09 0.151362E+10 0.127252E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.110564E+09 73405614.99 37158509.44 64520086.35 0.588454E+09
February 0.333759E+09 0.231223E+09 0.102536E+09 0.280811E+09 0.425553E+09
March 0.626634E+09 0.423252E+09 0.203383E+09 0.607893E+09 0.363449E+09
April 0.744354E+09 0.462756E+09 0.281598E+09 0.805453E+09 0.221890E+09
May 0.636949E+09 0.331012E+09 0.305937E+09 0.710571E+09 0.109492E+09
June 0.560728E+09 0.229663E+09 0.331065E+09 0.651948E+09 45658264.21
July 0.556956E+09 0.241666E+09 0.315290E+09 0.664839E+09 50613466.14
August 0.578740E+09 0.319082E+09 0.259658E+09 0.675685E+09 84759733.13
September 0.446438E+09 0.266429E+09 0.180009E+09 0.472183E+09 0.165189E+09
October 0.341020E+09 0.215814E+09 0.125207E+09 0.308799E+09 0.306274E+09
November 0.178690E+09 0.125635E+09 53054557.55 0.118409E+09 0.526321E+09
December 32650088.02 22957571.06 9692516.96 6131842.77 0.652319E+09
           
Annual Sum or Average 0.514748E+10 0.294290E+10 0.220459E+10 0.536724E+10 0.353997E+10
Minimum of Months 32650088.02 22957571.06 9692516.96 6131842.77 45658264.21
Maximum of Months 0.744354E+09 0.462756E+09 0.331065E+09 0.805453E+09 0.652319E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_6_FLR_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 8903365.66 0.00 8903365.66 0.00 0.652460E+09
February 35548435.04 0.00 35548435.04 0.00 0.522569E+09
March 0.105429E+09 20769.03 0.105408E+09 9186366.29 0.432081E+09
April 0.186535E+09 5554766.90 0.180981E+09 75267231.66 0.218509E+09
May 0.295088E+09 47938100.07 0.247150E+09 0.232064E+09 87908456.69
June 0.369268E+09 82313943.57 0.286954E+09 0.376459E+09 33364641.93
July 0.322713E+09 54364303.60 0.268349E+09 0.338293E+09 41364935.49
August 0.208037E+09 12822498.21 0.195214E+09 0.179155E+09 76340212.23
September 0.110825E+09 387910.37 0.110437E+09 45469130.20 0.173243E+09
October 55405927.66 0.00 55405927.66 4410047.24 0.362903E+09
November 16639755.89 0.00 16639755.89 0.00 0.613282E+09
December 2700813.42 0.00 2700813.42 0.00 0.683059E+09
           
Annual Sum or Average 0.171709E+10 0.203402E+09 0.151369E+10 0.126030E+10 0.389708E+10
Minimum of Months 2700813.42 0.00 2700813.42 0.00 33364641.93
Maximum of Months 0.369268E+09 82313943.57 0.286954E+09 0.376459E+09 0.683059E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_6_FLR_3_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 49579463.84 18581123.47 30998340.38 6803075.24 0.118364E+10
February 0.231022E+09 0.110948E+09 0.120073E+09 0.122404E+09 0.881187E+09
March 0.715425E+09 0.361845E+09 0.353579E+09 0.607172E+09 0.716375E+09
April 0.920846E+09 0.465817E+09 0.455029E+09 0.854176E+09 0.371689E+09
May 0.138407E+10 0.779723E+09 0.604352E+09 0.152166E+10 0.176431E+09
June 0.122743E+10 0.571977E+09 0.655454E+09 0.141020E+10 70894879.30
July 0.120787E+10 0.586057E+09 0.621808E+09 0.142524E+10 82863041.50
August 0.970784E+09 0.474845E+09 0.495938E+09 0.109483E+10 0.142836E+09
September 0.588361E+09 0.265743E+09 0.322618E+09 0.562620E+09 0.299638E+09
October 0.329733E+09 0.133619E+09 0.196115E+09 0.242492E+09 0.615005E+09
November 66562843.98 24447723.86 42115120.13 5527973.00 0.110481E+10
December 9834683.28 2409699.07 7424984.20 0.00 0.127207E+10
           
Annual Sum or Average 0.770152E+10 0.379601E+10 0.390551E+10 0.785312E+10 0.691743E+10
Minimum of Months 9834683.28 2409699.07 7424984.20 0.00 70894879.30
Maximum of Months 0.138407E+10 0.779723E+09 0.655454E+09 0.152166E+10 0.127207E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 11275550.84 0.00 11275550.84 0.00 0.870075E+09
February 45019849.99 0.00 45019849.99 0.00 0.701637E+09
March 0.133519E+09 26302.67 0.133492E+09 10088674.79 0.576852E+09
April 0.236235E+09 7034761.79 0.229201E+09 94195235.90 0.292187E+09
May 0.373711E+09 60710579.01 0.313000E+09 0.296504E+09 0.123500E+09
June 0.467655E+09 0.104245E+09 0.363410E+09 0.470819E+09 51330999.01
July 0.408696E+09 68848960.32 0.339847E+09 0.424165E+09 63301652.90
August 0.263465E+09 16238884.92 0.247226E+09 0.224389E+09 0.111111E+09
September 0.140353E+09 491264.00 0.139861E+09 55805355.32 0.235839E+09
October 70168111.46 0.00 70168111.46 4759243.24 0.490528E+09
November 21073200.92 0.00 21073200.92 0.00 0.818665E+09
December 3420409.78 0.00 3420409.78 0.00 0.908509E+09
           
Annual Sum or Average 0.217459E+10 0.257596E+09 0.191699E+10 0.158073E+10 0.524354E+10
Minimum of Months 3420409.78 0.00 3420409.78 0.00 51330999.01
Maximum of Months 0.467655E+09 0.104245E+09 0.363410E+09 0.470819E+09 0.908509E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 4156634.92 0.00 4156634.92 0.00 0.320712E+09
February 16596180.83 0.00 16596180.83 0.00 0.258652E+09
March 49220473.54 9696.25 49210777.28 3719103.27 0.212652E+09
April 87086120.75 2593304.48 84492816.26 34724264.27 0.107712E+09
May 0.137765E+09 22380433.25 0.115385E+09 0.109304E+09 45527034.51
June 0.172397E+09 38429176.73 0.133968E+09 0.173563E+09 18922731.68
July 0.150662E+09 25380577.58 0.125282E+09 0.156365E+09 23335610.37
August 97124191.36 5986325.38 91137865.98 82719179.08 40960283.98
September 51739743.37 181100.25 51558643.12 20572164.69 86940014.63
October 25866871.32 0.00 25866871.32 1754454.12 0.180829E+09
November 7768454.43 0.00 7768454.43 0.00 0.301772E+09
December 1260904.67 0.00 1260904.67 0.00 0.334810E+09
           
Annual Sum or Average 0.801644E+09 94960613.94 0.706683E+09 0.582721E+09 0.193282E+10
Minimum of Months 1260904.67 0.00 1260904.67 0.00 18922731.68
Maximum of Months 0.172397E+09 38429176.73 0.133968E+09 0.173563E+09 0.334810E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 51588774.92 34250764.15 17338010.77 28858406.40 0.288367E+09
February 0.155731E+09 0.107888E+09 47842898.63 0.128905E+09 0.207357E+09
March 0.292385E+09 0.197488E+09 94897488.90 0.284778E+09 0.175055E+09
April 0.347313E+09 0.215920E+09 0.131392E+09 0.379642E+09 0.107662E+09
May 0.297198E+09 0.154449E+09 0.142749E+09 0.334892E+09 57341107.12
June 0.261634E+09 0.107160E+09 0.154474E+09 0.304048E+09 27475918.07
July 0.259874E+09 0.112760E+09 0.147113E+09 0.310438E+09 29482383.14
August 0.270038E+09 0.148882E+09 0.121156E+09 0.316791E+09 45405678.20
September 0.208306E+09 0.124315E+09 83991627.46 0.221978E+09 81526579.82
October 0.159119E+09 0.100698E+09 58420891.65 0.143207E+09 0.149443E+09
November 83376003.23 58620960.47 24755042.76 52976608.86 0.257198E+09
December 15234399.50 10711910.15 4522489.35 2538921.89 0.319902E+09
           
Annual Sum or Average 0.240180E+10 0.137314E+10 0.102865E+10 0.250905E+10 0.174622E+10
Minimum of Months 15234399.50 10711910.15 4522489.35 2538921.89 27475918.07
Maximum of Months 0.347313E+09 0.215920E+09 0.154474E+09 0.379642E+09 0.319902E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.140022E+09 92963579.75 47058907.64 78327617.82 0.782686E+09
February 0.422685E+09 0.292830E+09 0.129855E+09 0.349876E+09 0.562809E+09
March 0.793593E+09 0.536022E+09 0.257571E+09 0.772946E+09 0.475135E+09
April 0.942678E+09 0.586052E+09 0.356626E+09 0.103043E+10 0.292218E+09
May 0.806656E+09 0.419206E+09 0.387450E+09 0.908965E+09 0.155635E+09
June 0.710127E+09 0.290854E+09 0.419273E+09 0.825249E+09 74575261.71
July 0.705350E+09 0.306055E+09 0.399295E+09 0.842591E+09 80021218.33
August 0.732938E+09 0.404097E+09 0.328841E+09 0.859836E+09 0.123240E+09
September 0.565386E+09 0.337415E+09 0.227970E+09 0.602494E+09 0.221280E+09
October 0.431881E+09 0.273315E+09 0.158566E+09 0.388692E+09 0.405620E+09
November 0.226300E+09 0.159109E+09 67190249.58 0.143789E+09 0.698088E+09
December 41349276.37 29074315.21 12274961.16 6891153.34 0.868279E+09
           
Annual Sum or Average 0.651896E+10 0.372699E+10 0.279197E+10 0.681008E+10 0.473959E+10
Minimum of Months 41349276.37 29074315.21 12274961.16 6891153.34 74575261.71
Maximum of Months 0.942678E+09 0.586052E+09 0.419273E+09 0.103043E+10 0.868279E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.110564E+09 73405614.99 37158509.44 65024896.91 0.584731E+09
February 0.333759E+09 0.231223E+09 0.102536E+09 0.283171E+09 0.422380E+09
March 0.626634E+09 0.423252E+09 0.203383E+09 0.615505E+09 0.360360E+09
April 0.744354E+09 0.462756E+09 0.281598E+09 0.807832E+09 0.222306E+09
May 0.636949E+09 0.331012E+09 0.305937E+09 0.715117E+09 0.109651E+09
June 0.560728E+09 0.229663E+09 0.331065E+09 0.652890E+09 47245604.01
July 0.556956E+09 0.241666E+09 0.315290E+09 0.667211E+09 50941046.52
August 0.578740E+09 0.319082E+09 0.259658E+09 0.678407E+09 83615663.15
September 0.446438E+09 0.266429E+09 0.180009E+09 0.477189E+09 0.162196E+09
October 0.341020E+09 0.215814E+09 0.125207E+09 0.312797E+09 0.303285E+09
November 0.178690E+09 0.125635E+09 53054557.55 0.119434E+09 0.521480E+09
December 32650088.02 22957571.06 9692516.96 6236135.66 0.648337E+09
           
Annual Sum or Average 0.514748E+10 0.294290E+10 0.220459E+10 0.540081E+10 0.351653E+10
Minimum of Months 32650088.02 22957571.06 9692516.96 6236135.66 47245604.01
Maximum of Months 0.744354E+09 0.462756E+09 0.331065E+09 0.807832E+09 0.648337E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_1_FLR_6_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 23027276.62 4040088.38 18987188.23 0.00 0.120616E+10
February 0.123676E+09 43420979.82 80255376.49 25893327.06 0.924557E+09
March 0.410572E+09 0.177514E+09 0.233059E+09 0.233819E+09 0.742488E+09
April 0.939386E+09 0.487081E+09 0.452305E+09 0.884565E+09 0.402466E+09
May 0.941543E+09 0.428795E+09 0.512747E+09 0.958067E+09 0.187872E+09
June 0.998144E+09 0.425339E+09 0.572805E+09 0.111505E+10 81330734.70
July 0.861900E+09 0.325115E+09 0.536786E+09 0.978093E+09 89971485.68
August 0.711248E+09 0.302051E+09 0.409197E+09 0.760059E+09 0.150095E+09
September 0.414345E+09 0.172645E+09 0.241700E+09 0.345892E+09 0.309054E+09
October 0.168359E+09 50713878.96 0.117645E+09 63712689.99 0.645937E+09
November 66100104.82 24494500.61 41605604.21 7508429.10 0.109832E+10
December 6052526.62 646601.17 5405925.45 0.00 0.127091E+10
           
Annual Sum or Average 0.566435E+10 0.244186E+10 0.322250E+10 0.537266E+10 0.710915E+10
Minimum of Months 6052526.62 646601.17 5405925.45 0.00 81330734.70
Maximum of Months 0.998144E+09 0.487081E+09 0.572805E+09 0.111505E+10 0.127091E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_2_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 8903365.66 0.00 8903365.66 0.00 0.649542E+09
February 35548435.04 0.00 35548435.04 0.00 0.520247E+09
March 0.105429E+09 20769.03 0.105408E+09 10888029.65 0.426809E+09
April 0.186535E+09 5554766.90 0.180981E+09 80172943.98 0.217988E+09
May 0.295088E+09 47938100.07 0.247150E+09 0.242357E+09 86915945.85
June 0.369268E+09 82313943.57 0.286954E+09 0.380271E+09 33036851.22
July 0.322713E+09 54364303.60 0.268349E+09 0.343774E+09 40661913.33
August 0.208037E+09 12822498.21 0.195214E+09 0.185680E+09 74554033.71
September 0.110825E+09 387910.37 0.110437E+09 51179871.18 0.168197E+09
October 55405927.66 0.00 55405927.66 5666121.49 0.359374E+09
November 16639755.89 0.00 16639755.89 0.00 0.607696E+09
December 2700813.42 0.00 2700813.42 0.00 0.679155E+09
           
Annual Sum or Average 0.171709E+10 0.203402E+09 0.151369E+10 0.129999E+10 0.386418E+10
Minimum of Months 2700813.42 0.00 2700813.42 0.00 33036851.22
Maximum of Months 0.369268E+09 82313943.57 0.286954E+09 0.380271E+09 0.679155E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_2_FLR_6_WALL_WEST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 23027276.62 4040088.38 18987188.23 0.00 0.120640E+10
February 0.123676E+09 43420979.82 80255376.49 27161763.41 0.923298E+09
March 0.410572E+09 0.177514E+09 0.233059E+09 0.241877E+09 0.736471E+09
April 0.939386E+09 0.487081E+09 0.452305E+09 0.904551E+09 0.396375E+09
May 0.941543E+09 0.428795E+09 0.512747E+09 0.970975E+09 0.183927E+09
June 0.998144E+09 0.425339E+09 0.572805E+09 0.112155E+10 77872234.95
July 0.861900E+09 0.325115E+09 0.536786E+09 0.985247E+09 87398840.79
August 0.711248E+09 0.302051E+09 0.409197E+09 0.771407E+09 0.147011E+09
September 0.414345E+09 0.172645E+09 0.241700E+09 0.357458E+09 0.303668E+09
October 0.168359E+09 50713878.96 0.117645E+09 67698717.03 0.642364E+09
November 66100104.82 24494500.61 41605604.21 7928501.94 0.109799E+10
December 6052526.62 646601.17 5405925.45 0.00 0.127086E+10
           
Annual Sum or Average 0.566435E+10 0.244186E+10 0.322250E+10 0.545586E+10 0.707364E+10
Minimum of Months 6052526.62 646601.17 5405925.45 0.00 77872234.95
Maximum of Months 0.998144E+09 0.487081E+09 0.572805E+09 0.112155E+10 0.127086E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.162153E+09 0.107656E+09 54496520.21 92489239.87 0.871739E+09
February 0.489490E+09 0.339111E+09 0.150379E+09 0.402646E+09 0.633615E+09
March 0.919020E+09 0.620739E+09 0.298280E+09 0.879457E+09 0.543273E+09
April 0.109167E+10 0.678677E+09 0.412990E+09 0.117069E+10 0.331140E+09
May 0.934147E+09 0.485461E+09 0.448686E+09 0.104392E+10 0.161442E+09
June 0.822362E+09 0.336823E+09 0.485539E+09 0.958932E+09 68503096.75
July 0.816830E+09 0.354427E+09 0.462403E+09 0.978172E+09 74381275.76
August 0.848778E+09 0.467964E+09 0.380814E+09 0.990134E+09 0.123638E+09
September 0.654744E+09 0.390743E+09 0.264001E+09 0.687752E+09 0.245241E+09
October 0.500139E+09 0.316512E+09 0.183627E+09 0.444166E+09 0.457972E+09
November 0.262066E+09 0.184256E+09 77809600.31 0.169667E+09 0.777988E+09
December 47884487.52 33669481.21 14215006.31 8702535.85 0.965255E+09
           
Annual Sum or Average 0.754928E+10 0.431604E+10 0.323324E+10 0.782673E+10 0.525419E+10
Minimum of Months 47884487.52 33669481.21 14215006.31 8702535.85 68503096.75
Maximum of Months 0.109167E+10 0.678677E+09 0.485539E+09 0.117069E+10 0.965255E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: BANQUET_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 62321199.25 0.00 62321199.25 0.00 0.485571E+10
February 0.248830E+09 0.00 0.248830E+09 0.00 0.393402E+10
March 0.737972E+09 145377.71 0.737826E+09 43996759.36 0.332006E+10
April 0.130570E+10 38881895.68 0.126682E+10 0.471768E+09 0.172430E+10
May 0.206554E+10 0.335554E+09 0.172998E+10 0.157046E+10 0.702899E+09
June 0.258478E+10 0.576176E+09 0.200861E+10 0.256916E+10 0.284831E+09
July 0.225891E+10 0.380536E+09 0.187837E+10 0.231143E+10 0.350726E+09
August 0.145620E+10 89754088.05 0.136645E+10 0.119721E+10 0.627359E+09
September 0.775744E+09 2715269.72 0.773028E+09 0.269364E+09 0.141283E+10
October 0.387827E+09 0.00 0.387827E+09 16542117.31 0.289702E+10
November 0.116474E+09 0.00 0.116474E+09 0.00 0.455349E+10
December 18904977.91 0.00 18904977.91 0.00 0.504166E+10
           
Annual Sum or Average 0.120192E+11 0.142376E+10 0.105954E+11 0.844993E+10 0.297049E+11
Minimum of Months 18904977.91 0.00 18904977.91 0.00 0.284831E+09
Maximum of Months 0.258478E+10 0.576176E+09 0.200861E+10 0.256916E+10 0.504166E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: DINING_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 62321199.25 0.00 62321199.25 0.00 0.493390E+10
February 0.248830E+09 0.00 0.248830E+09 0.00 0.400336E+10
March 0.737972E+09 145377.71 0.737826E+09 38422877.93 0.338846E+10
April 0.130570E+10 38881895.68 0.126682E+10 0.450466E+09 0.176006E+10
May 0.206554E+10 0.335554E+09 0.172998E+10 0.154242E+10 0.715623E+09
June 0.258478E+10 0.576176E+09 0.200861E+10 0.254702E+10 0.291304E+09
July 0.225891E+10 0.380536E+09 0.187837E+10 0.229013E+10 0.358790E+09
August 0.145620E+10 89754088.05 0.136645E+10 0.117543E+10 0.641497E+09
September 0.775744E+09 2715269.72 0.773028E+09 0.253896E+09 0.144957E+10
October 0.387827E+09 0.00 0.387827E+09 13363151.66 0.296568E+10
November 0.116474E+09 0.00 0.116474E+09 0.00 0.463025E+10
December 18904977.91 0.00 18904977.91 0.00 0.511783E+10
           
Annual Sum or Average 0.120192E+11 0.142376E+10 0.105954E+11 0.831115E+10 0.302563E+11
Minimum of Months 18904977.91 0.00 18904977.91 0.00 0.291304E+09
Maximum of Months 0.258478E+10 0.576176E+09 0.200861E+10 0.254702E+10 0.511783E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: KITCHEN_FLR_6_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 8903365.66 0.00 8903365.66 0.00 0.587823E+09
February 35548435.04 0.00 35548435.04 0.00 0.467856E+09
March 0.105429E+09 20769.03 0.105408E+09 20078711.29 0.387387E+09
April 0.186535E+09 5554766.90 0.180981E+09 0.124696E+09 0.207510E+09
May 0.295088E+09 47938100.07 0.247150E+09 0.317935E+09 91879512.07
June 0.369268E+09 82313943.57 0.286954E+09 0.472896E+09 39008239.06
July 0.322713E+09 54364303.60 0.268349E+09 0.438506E+09 46562867.04
August 0.208037E+09 12822498.21 0.195214E+09 0.267462E+09 76972333.76
September 0.110825E+09 387910.37 0.110437E+09 90407007.51 0.151748E+09
October 55405927.66 0.00 55405927.66 12618503.51 0.320224E+09
November 16639755.89 0.00 16639755.89 0.00 0.548062E+09
December 2700813.42 0.00 2700813.42 0.00 0.616259E+09
           
Annual Sum or Average 0.171709E+10 0.203402E+09 0.151369E+10 0.174460E+10 0.354129E+10
Minimum of Months 2700813.42 0.00 2700813.42 0.00 39008239.06
Maximum of Months 0.369268E+09 82313943.57 0.286954E+09 0.472896E+09 0.616259E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: KITCHEN_FLR_6_WALL_EAST_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 99151886.15 37159607.94 61992278.21 20559144.93 0.213594E+10
February 0.462011E+09 0.221881E+09 0.240130E+09 0.287251E+09 0.159824E+10
March 0.143075E+10 0.723639E+09 0.707109E+09 0.132371E+10 0.132366E+10
April 0.184156E+10 0.931568E+09 0.909994E+09 0.192976E+10 0.728755E+09
May 0.276795E+10 0.155933E+10 0.120862E+10 0.335910E+10 0.357302E+09
June 0.245469E+10 0.114387E+10 0.131082E+10 0.317525E+10 0.156793E+09
July 0.241556E+10 0.117203E+10 0.124353E+10 0.322103E+10 0.180525E+09
August 0.194143E+10 0.949623E+09 0.991806E+09 0.252504E+10 0.288127E+09
September 0.117664E+10 0.531449E+09 0.645190E+09 0.133249E+10 0.550860E+09
October 0.659420E+09 0.267219E+09 0.392201E+09 0.566929E+09 0.111600E+10
November 0.133116E+09 48891975.52 84224258.84 18703448.67 0.197426E+10
December 19667969.78 4819055.91 14848913.87 0.00 0.229921E+10
           
Annual Sum or Average 0.154019E+11 0.759149E+10 0.781046E+10 0.177598E+11 0.127097E+11
Minimum of Months 19667969.78 4819055.91 14848913.87 0.00 0.156793E+09
Maximum of Months 0.276795E+10 0.155933E+10 0.131082E+10 0.335910E+10 0.229921E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.110564E+09 73405614.99 37158509.44 73919209.60 0.531842E+09
February 0.333759E+09 0.231223E+09 0.102536E+09 0.304140E+09 0.388164E+09
March 0.626634E+09 0.423252E+09 0.203383E+09 0.655212E+09 0.338362E+09
April 0.744354E+09 0.462756E+09 0.281598E+09 0.872801E+09 0.210167E+09
May 0.636949E+09 0.331012E+09 0.305937E+09 0.798668E+09 0.108308E+09
June 0.560728E+09 0.229663E+09 0.331065E+09 0.750301E+09 51739479.01
July 0.556956E+09 0.241666E+09 0.315290E+09 0.767114E+09 55335146.11
August 0.578740E+09 0.319082E+09 0.259658E+09 0.766518E+09 81648261.60
September 0.446438E+09 0.266429E+09 0.180009E+09 0.533846E+09 0.149460E+09
October 0.341020E+09 0.215814E+09 0.125207E+09 0.343434E+09 0.280512E+09
November 0.178690E+09 0.125635E+09 53054557.55 0.133080E+09 0.473828E+09
December 32650088.02 22957571.06 9692516.96 8578632.56 0.588062E+09
           
Annual Sum or Average 0.514748E+10 0.294290E+10 0.220459E+10 0.600761E+10 0.325743E+10
Minimum of Months 32650088.02 22957571.06 9692516.96 8578632.56 51739479.01
Maximum of Months 0.744354E+09 0.462756E+09 0.331065E+09 0.872801E+09 0.588062E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 11275550.84 0.00 11275550.84 0.00 0.869674E+09
February 45019849.99 0.00 45019849.99 0.00 0.702625E+09
March 0.133519E+09 26302.67 0.133492E+09 9190902.30 0.582478E+09
April 0.236235E+09 7034761.79 0.229201E+09 89250842.91 0.294216E+09
May 0.373711E+09 60710579.01 0.313000E+09 0.290739E+09 0.123115E+09
June 0.467655E+09 0.104245E+09 0.363410E+09 0.461668E+09 52167840.57
July 0.408696E+09 68848960.32 0.339847E+09 0.414910E+09 64591794.85
August 0.263465E+09 16238884.92 0.247226E+09 0.217831E+09 0.111949E+09
September 0.140353E+09 491264.00 0.139861E+09 53379649.52 0.237208E+09
October 70168111.46 0.00 70168111.46 4155023.10 0.496873E+09
November 21073200.92 0.00 21073200.92 0.00 0.815649E+09
December 3420409.78 0.00 3420409.78 0.00 0.906847E+09
           
Annual Sum or Average 0.217459E+10 0.257596E+09 0.191699E+10 0.154112E+10 0.525739E+10
Minimum of Months 3420409.78 0.00 3420409.78 0.00 52167840.57
Maximum of Months 0.467655E+09 0.104245E+09 0.363410E+09 0.461668E+09 0.906847E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 10088278.06 0.00 10088278.06 0.00 0.778100E+09
February 40279430.37 0.00 40279430.37 0.00 0.628467E+09
March 0.119460E+09 23533.10 0.119436E+09 8223135.11 0.521146E+09
April 0.211361E+09 6294028.03 0.205067E+09 79853067.33 0.263236E+09
May 0.334360E+09 54317985.07 0.280042E+09 0.260125E+09 0.110152E+09
June 0.418413E+09 93268768.51 0.325144E+09 0.413056E+09 46674764.62
July 0.365662E+09 61599425.66 0.304062E+09 0.371221E+09 57790523.59
August 0.235723E+09 14528991.87 0.221194E+09 0.194895E+09 0.100161E+09
September 0.125574E+09 439535.76 0.125134E+09 47758974.68 0.212231E+09
October 62779675.19 0.00 62779675.19 3717514.91 0.444460E+09
November 18854272.71 0.00 18854272.71 0.00 0.729763E+09
December 3060253.59 0.00 3060253.59 0.00 0.811359E+09
           
Annual Sum or Average 0.194561E+10 0.230472E+09 0.171514E+10 0.137885E+10 0.470354E+10
Minimum of Months 3060253.59 0.00 3060253.59 0.00 46674764.62
Maximum of Months 0.418413E+09 93268768.51 0.325144E+09 0.413056E+09 0.811359E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.412769E+09 0.274045E+09 0.138724E+09 0.230099E+09 0.230689E+10
February 0.124602E+10 0.863226E+09 0.382798E+09 0.102775E+10 0.166034E+10
March 0.233941E+10 0.158013E+10 0.759288E+09 0.226269E+10 0.140948E+10
April 0.277890E+10 0.172761E+10 0.105129E+10 0.301306E+10 0.863968E+09
May 0.237792E+10 0.123577E+10 0.114216E+10 0.265675E+10 0.456796E+09
June 0.209337E+10 0.857402E+09 0.123596E+10 0.240307E+10 0.224273E+09
July 0.207928E+10 0.902212E+09 0.117707E+10 0.245361E+10 0.241411E+09
August 0.216061E+10 0.119123E+10 0.969383E+09 0.251096E+10 0.366826E+09
September 0.166669E+10 0.994658E+09 0.672028E+09 0.176237E+10 0.654536E+09
October 0.127313E+10 0.805697E+09 0.467434E+09 0.113446E+10 0.120858E+10
November 0.667103E+09 0.469034E+09 0.198068E+09 0.423941E+09 0.205073E+10
December 0.121893E+09 85707453.80 36185054.02 20365356.66 0.255670E+10
           
Annual Sum or Average 0.192171E+11 0.109867E+11 0.823039E+10 0.198991E+11 0.140005E+11
Minimum of Months 0.121893E+09 85707453.80 36185054.02 20365356.66 0.224273E+09
Maximum of Months 0.277890E+10 0.172761E+10 0.123596E+10 0.301306E+10 0.255670E+10



Table of Contents

Report: WindowZoneSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 119.48 1097.02 208.78 138.61 70.17 0.00 0.00
February 577.51 879.26 697.78 483.41 214.37 0.00 0.00
March 1142.58 673.59 1183.30 799.24 384.05 0.00 0.00
April 1566.63 428.45 1452.44 902.97 549.47 0.00 0.00
May 1350.77 207.94 1202.77 625.06 577.71 0.00 0.00
June 1275.16 97.54 1094.14 448.14 646.00 0.00 0.00
July 1257.61 102.02 1051.72 456.35 595.37 0.00 0.00
August 1276.44 163.43 1092.85 602.53 490.32 0.00 0.00
September 918.72 319.82 871.13 519.88 351.25 0.00 0.00
October 577.72 571.87 643.96 407.53 236.43 0.00 0.00
November 223.60 1021.69 348.67 245.15 103.52 0.00 0.00
December 10.95 1219.28 61.65 43.35 18.30 0.00 0.00
               
Annual Sum or Average 858.89 563.66 825.55 471.98 353.57 0.00 0.00
Minimum of Months 10.95 97.54 61.65 43.35 18.30 0.00 0.00
Maximum of Months 1566.63 1219.28 1452.44 902.97 646.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 333.90 3080.07 587.92 390.33 197.59 0.00 0.00
February 1615.64 2469.57 1964.90 1361.25 603.64 0.00 0.00
March 3196.16 1902.62 3332.09 2250.62 1081.47 0.00 0.00
April 4384.52 1239.62 4089.98 2542.70 1547.28 0.00 0.00
May 3765.58 627.33 3386.93 1760.14 1626.79 0.00 0.00
June 3547.92 304.90 3081.01 1261.93 1819.08 0.00 0.00
July 3500.21 318.06 2961.57 1285.05 1676.52 0.00 0.00
August 3561.48 499.99 3077.41 1696.70 1380.71 0.00 0.00
September 2563.26 939.25 2453.03 1463.94 989.09 0.00 0.00
October 1612.46 1621.80 1813.35 1147.58 665.78 0.00 0.00
November 624.42 2866.62 981.84 690.33 291.52 0.00 0.00
December 30.42 3419.96 173.61 122.08 51.54 0.00 0.00
               
Annual Sum or Average 2396.84 1603.36 2324.69 1329.07 995.63 0.00 0.00
Minimum of Months 30.42 304.90 173.61 122.08 51.54 0.00 0.00
Maximum of Months 4384.52 3419.96 4089.98 2542.70 1819.08 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 432.59 4163.34 763.74 507.06 256.68 0.00 0.00
February 2115.06 3332.08 2552.51 1768.34 784.17 0.00 0.00
March 4211.92 2567.65 4328.57 2923.68 1404.89 0.00 0.00
April 5776.39 1682.02 5313.12 3303.11 2010.01 0.00 0.00
May 4947.33 868.37 4399.81 2286.52 2113.29 0.00 0.00
June 4654.97 426.66 4002.41 1639.32 2363.09 0.00 0.00
July 4586.95 447.69 3847.25 1669.35 2177.90 0.00 0.00
August 4665.36 699.49 3997.73 2204.11 1793.62 0.00 0.00
September 3353.53 1313.82 3186.63 1901.75 1284.88 0.00 0.00
October 2107.75 2230.47 2355.65 1490.77 864.88 0.00 0.00
November 811.81 3873.33 1275.47 896.77 378.70 0.00 0.00
December 38.57 4612.28 225.54 158.58 66.95 0.00 0.00
               
Annual Sum or Average 3144.73 2179.29 3019.91 1726.53 1293.37 0.00 0.00
Minimum of Months 38.57 426.66 225.54 158.58 66.95 0.00 0.00
Maximum of Months 5776.39 4612.28 5313.12 3303.11 2363.09 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 6.98 655.49 49.88 28.91 20.96 0.00 0.00
February 87.99 521.18 189.09 113.53 75.56 0.00 0.00
March 293.18 390.30 387.25 224.30 162.95 0.00 0.00
April 646.18 233.96 649.59 366.45 283.14 0.00 0.00
May 624.09 110.17 589.34 283.68 305.66 0.00 0.00
June 683.59 49.67 601.42 252.70 348.72 0.00 0.00
July 615.69 53.05 529.74 211.61 318.13 0.00 0.00
August 537.08 87.58 481.63 231.90 249.72 0.00 0.00
September 312.91 180.62 332.09 169.40 162.70 0.00 0.00
October 118.64 335.47 190.18 99.51 90.67 0.00 0.00
November 25.84 608.25 94.44 57.92 36.52 0.00 0.00
December 0.00 718.59 14.45 8.81 5.64 0.00 0.00
               
Annual Sum or Average 330.37 327.78 342.84 170.75 172.09 0.00 0.00
Minimum of Months 0.00 49.67 14.45 8.81 5.64 0.00 0.00
Maximum of Months 683.59 718.59 649.59 366.45 348.72 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 696.93 11.92 1.51 10.41 0.00 0.00
February 5.62 594.97 65.82 17.95 47.87 0.00 0.00
March 84.87 426.89 192.65 66.28 126.37 0.00 0.00
April 375.14 233.43 434.38 190.06 244.32 0.00 0.00
May 444.63 94.08 461.71 177.99 283.71 0.00 0.00
June 575.93 38.68 527.55 195.85 331.70 0.00 0.00
July 494.16 45.57 442.28 141.68 300.60 0.00 0.00
August 353.60 80.67 343.22 117.56 225.66 0.00 0.00
September 153.62 182.77 202.61 66.76 135.86 0.00 0.00
October 23.36 372.87 83.54 18.93 64.61 0.00 0.00
November 1.11 662.42 31.92 9.45 22.47 0.00 0.00
December 0.00 732.38 3.27 0.24 3.03 0.00 0.00
               
Annual Sum or Average 210.28 345.50 234.06 83.88 150.18 0.00 0.00
Minimum of Months 0.00 38.68 3.27 0.24 3.03 0.00 0.00
Maximum of Months 575.93 732.38 527.55 195.85 331.70 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 19.28 171.95 33.02 21.92 11.10 0.00 0.00
February 92.83 137.52 110.35 76.45 33.90 0.00 0.00
March 182.08 107.56 187.13 126.39 60.74 0.00 0.00
April 247.09 73.24 229.69 142.80 86.90 0.00 0.00
May 211.66 37.54 190.21 98.85 91.36 0.00 0.00
June 199.77 18.14 173.03 70.87 102.16 0.00 0.00
July 197.26 18.97 166.32 72.17 94.15 0.00 0.00
August 200.36 29.96 172.83 95.29 77.54 0.00 0.00
September 144.30 55.43 137.76 82.21 55.55 0.00 0.00
October 91.91 90.82 101.84 64.45 37.39 0.00 0.00
November 36.39 158.73 55.14 38.77 16.37 0.00 0.00
December 1.81 191.08 9.75 6.86 2.89 0.00 0.00
               
Annual Sum or Average 135.51 90.69 130.55 74.64 55.91 0.00 0.00
Minimum of Months 1.81 18.14 9.75 6.86 2.89 0.00 0.00
Maximum of Months 247.09 191.08 229.69 142.80 102.16 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 200.22 2.66 0.00 2.66 0.00 0.00
February 0.00 178.03 11.76 0.00 11.76 0.00 0.00
March 2.83 131.49 31.49 0.01 31.49 0.00 0.00
April 25.51 67.51 57.58 1.71 55.87 0.00 0.00
May 75.02 25.77 88.15 14.32 73.83 0.00 0.00
June 121.68 9.83 113.99 25.41 88.58 0.00 0.00
July 106.39 11.76 96.40 16.24 80.16 0.00 0.00
August 57.76 21.97 62.15 3.83 58.32 0.00 0.00
September 15.21 53.72 34.21 0.12 34.09 0.00 0.00
October 1.32 111.94 16.55 0.00 16.55 0.00 0.00
November 0.00 194.50 5.14 0.00 5.14 0.00 0.00
December 0.00 209.30 0.81 0.00 0.81 0.00 0.00
               
Annual Sum or Average 34.01 100.93 43.56 5.16 38.40 0.00 0.00
Minimum of Months 0.00 9.83 0.81 0.00 0.81 0.00 0.00
Maximum of Months 121.68 209.30 113.99 25.41 88.58 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 14.83 650.39 59.79 34.34 25.45 0.00 0.00
February 140.83 516.84 233.46 141.44 92.02 0.00 0.00
March 431.22 388.23 501.07 293.12 207.95 0.00 0.00
April 624.75 222.25 642.44 358.25 284.19 0.00 0.00
May 825.46 102.62 754.56 414.70 339.86 0.00 0.00
June 791.48 43.12 689.88 309.27 380.60 0.00 0.00
July 776.78 48.65 658.91 309.04 349.87 0.00 0.00
August 655.31 83.05 578.53 296.42 282.11 0.00 0.00
September 391.35 176.58 399.23 205.31 193.91 0.00 0.00
October 192.72 334.74 250.43 130.46 119.97 0.00 0.00
November 24.34 606.14 94.62 57.90 36.72 0.00 0.00
December 0.00 716.36 15.86 9.47 6.39 0.00 0.00
               
Annual Sum or Average 407.36 323.18 407.44 213.69 193.75 0.00 0.00
Minimum of Months 0.00 43.12 15.86 9.47 6.39 0.00 0.00
Maximum of Months 825.46 716.36 754.56 414.70 380.60 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.94 683.92 21.83 6.94 14.90 0.00 0.00
February 35.23 564.89 110.19 45.86 64.33 0.00 0.00
March 212.09 410.75 306.47 135.11 171.37 0.00 0.00
April 349.79 218.91 427.23 181.86 245.37 0.00 0.00
May 653.34 97.26 626.93 309.01 317.91 0.00 0.00
June 687.99 38.91 616.01 252.43 363.58 0.00 0.00
July 657.80 45.75 571.45 239.11 332.35 0.00 0.00
August 474.94 81.12 440.12 182.07 258.05 0.00 0.00
September 229.67 177.51 269.75 102.67 167.07 0.00 0.00
October 81.43 354.35 143.79 49.89 93.91 0.00 0.00
November 0.66 661.37 32.10 9.43 22.67 0.00 0.00
December 0.00 729.96 4.68 0.90 3.78 0.00 0.00
               
Annual Sum or Average 283.63 337.57 298.66 126.82 171.84 0.00 0.00
Minimum of Months 0.00 38.91 4.68 0.90 3.78 0.00 0.00
Maximum of Months 687.99 729.96 626.93 309.01 363.58 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 18.62 823.07 77.30 47.50 29.80 0.00 0.00
February 140.11 657.50 264.56 165.64 98.92 0.00 0.00
March 360.95 498.41 473.68 273.87 199.81 0.00 0.00
April 586.56 301.37 622.42 313.12 309.30 0.00 0.00
May 604.24 130.95 603.10 245.20 357.89 0.00 0.00
June 675.15 57.33 621.84 208.60 413.24 0.00 0.00
July 641.64 67.64 569.21 191.55 377.66 0.00 0.00
August 549.33 115.11 509.10 214.76 294.34 0.00 0.00
September 341.69 235.50 372.60 178.40 194.21 0.00 0.00
October 169.26 426.13 256.51 139.64 116.87 0.00 0.00
November 39.40 764.31 130.60 84.00 46.60 0.00 0.00
December 0.19 904.49 22.87 14.85 8.02 0.00 0.00
               
Annual Sum or Average 344.87 413.99 377.25 172.90 204.35 0.00 0.00
Minimum of Months 0.19 57.33 22.87 14.85 8.02 0.00 0.00
Maximum of Months 675.15 904.49 622.42 313.12 413.24 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 7.13 651.50 49.88 28.91 20.96 0.00 0.00
February 88.85 517.87 189.09 113.53 75.56 0.00 0.00
March 294.07 388.72 387.25 224.30 162.95 0.00 0.00
April 644.70 232.80 649.59 366.45 283.14 0.00 0.00
May 622.46 108.85 589.34 283.68 305.66 0.00 0.00
June 681.23 48.76 601.42 252.70 348.72 0.00 0.00
July 613.73 52.05 529.74 211.61 318.13 0.00 0.00
August 535.94 86.14 481.63 231.90 249.72 0.00 0.00
September 313.84 178.11 332.09 169.40 162.70 0.00 0.00
October 119.60 333.43 190.18 99.51 90.67 0.00 0.00
November 26.37 602.31 94.44 57.92 36.52 0.00 0.00
December 0.00 714.23 14.45 8.81 5.64 0.00 0.00
               
Annual Sum or Average 330.01 325.32 342.84 170.75 172.09 0.00 0.00
Minimum of Months 0.00 48.76 14.45 8.81 5.64 0.00 0.00
Maximum of Months 681.23 714.23 649.59 366.45 348.72 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 692.93 11.92 1.51 10.41 0.00 0.00
February 5.78 591.25 65.82 17.95 47.87 0.00 0.00
March 85.21 425.15 192.65 66.28 126.37 0.00 0.00
April 375.03 232.15 434.38 190.06 244.32 0.00 0.00
May 444.84 92.96 461.71 177.99 283.71 0.00 0.00
June 574.62 38.00 527.55 195.85 331.70 0.00 0.00
July 493.13 44.74 442.28 141.68 300.60 0.00 0.00
August 353.76 79.15 343.22 117.56 225.66 0.00 0.00
September 155.34 179.73 202.61 66.76 135.86 0.00 0.00
October 23.99 370.61 83.54 18.93 64.61 0.00 0.00
November 1.15 656.15 31.92 9.45 22.47 0.00 0.00
December 0.00 728.05 3.27 0.24 3.03 0.00 0.00
               
Annual Sum or Average 210.34 342.95 234.06 83.88 150.18 0.00 0.00
Minimum of Months 0.00 38.00 3.27 0.24 3.03 0.00 0.00
Maximum of Months 574.62 728.05 527.55 195.85 331.70 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 34.53 325.47 60.54 40.19 20.35 0.00 0.00
February 166.44 261.91 202.34 140.17 62.16 0.00 0.00
March 328.35 202.83 343.12 231.76 111.37 0.00 0.00
April 451.65 127.75 421.17 261.84 159.33 0.00 0.00
May 389.76 60.28 348.77 181.25 167.52 0.00 0.00
June 369.96 26.43 317.27 129.95 187.32 0.00 0.00
July 365.21 27.77 304.97 132.33 172.64 0.00 0.00
August 369.67 46.16 316.90 174.72 142.18 0.00 0.00
September 265.34 94.61 252.60 150.75 101.85 0.00 0.00
October 165.83 170.99 186.73 118.17 68.56 0.00 0.00
November 65.46 300.15 101.11 71.09 30.02 0.00 0.00
December 3.25 360.38 17.88 12.57 5.31 0.00 0.00
               
Annual Sum or Average 248.18 166.61 239.39 136.86 102.53 0.00 0.00
Minimum of Months 3.25 26.43 17.88 12.57 5.31 0.00 0.00
Maximum of Months 451.65 360.38 421.17 261.84 187.32 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 1812.91 23.27 0.00 23.27 0.00 0.00
February 0.00 1626.17 102.86 0.00 102.86 0.00 0.00
March 16.43 1239.57 275.53 0.05 275.47 0.00 0.00
April 182.01 665.24 503.74 15.00 488.74 0.00 0.00
May 586.34 262.43 771.18 125.28 645.90 0.00 0.00
June 991.19 109.89 997.21 222.29 774.92 0.00 0.00
July 862.99 130.95 843.38 142.08 701.30 0.00 0.00
August 446.99 234.23 543.68 33.51 510.17 0.00 0.00
September 103.92 545.07 299.28 1.05 298.24 0.00 0.00
October 6.18 1081.62 144.80 0.00 144.80 0.00 0.00
November 0.00 1756.75 44.94 0.00 44.94 0.00 0.00
December 0.00 1882.34 7.06 0.00 7.06 0.00 0.00
               
Annual Sum or Average 267.95 941.94 381.13 45.15 335.98 0.00 0.00
Minimum of Months 0.00 109.89 7.06 0.00 7.06 0.00 0.00
Maximum of Months 991.19 1882.34 997.21 222.29 774.92 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 1842.11 23.27 0.00 23.27 0.00 0.00
February 0.00 1654.83 102.86 0.00 102.86 0.00 0.00
March 14.35 1265.11 275.53 0.05 275.47 0.00 0.00
April 173.79 679.04 503.74 15.00 488.74 0.00 0.00
May 575.87 267.18 771.18 125.28 645.90 0.00 0.00
June 982.65 112.39 997.21 222.29 774.92 0.00 0.00
July 855.04 133.96 843.38 142.08 701.30 0.00 0.00
August 438.86 239.51 543.68 33.51 510.17 0.00 0.00
September 97.95 559.25 299.28 1.05 298.24 0.00 0.00
October 4.99 1107.26 144.80 0.00 144.80 0.00 0.00
November 0.00 1786.36 44.94 0.00 44.94 0.00 0.00
December 0.00 1910.78 7.06 0.00 7.06 0.00 0.00
               
Annual Sum or Average 263.54 959.42 381.13 45.15 335.98 0.00 0.00
Minimum of Months 0.00 112.39 7.06 0.00 7.06 0.00 0.00
Maximum of Months 982.65 1910.78 997.21 222.29 774.92 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 14.85 1195.08 81.62 41.28 40.34 0.00 0.00
February 189.12 959.15 343.63 187.30 156.34 0.00 0.00
March 709.87 728.69 807.50 428.21 379.29 0.00 0.00
April 1116.73 429.68 1069.62 540.08 529.54 0.00 0.00
May 1665.09 202.19 1381.42 723.67 657.75 0.00 0.00
June 1692.46 91.03 1305.82 561.67 744.15 0.00 0.00
July 1650.14 102.86 1230.30 548.11 682.19 0.00 0.00
August 1326.85 164.86 1018.60 478.47 540.13 0.00 0.00
September 751.12 324.94 668.94 307.97 360.97 0.00 0.00
October 319.82 616.17 394.21 180.34 213.86 0.00 0.00
November 19.01 1116.37 126.72 67.33 59.38 0.00 0.00
December 0.00 1304.86 20.54 10.37 10.17 0.00 0.00
               
Annual Sum or Average 791.67 601.30 706.07 340.49 365.57 0.00 0.00
Minimum of Months 0.00 91.03 20.54 10.37 10.17 0.00 0.00
Maximum of Months 1692.46 1304.86 1381.42 723.67 744.15 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 51.91 1442.50 162.09 102.32 59.77 0.00 0.00
February 340.65 1152.36 550.32 356.82 193.49 0.00 0.00
March 793.37 880.37 967.89 589.97 377.92 0.00 0.00
April 1216.63 537.33 1244.79 671.66 573.13 0.00 0.00
May 1174.24 234.30 1152.18 504.33 647.85 0.00 0.00
June 1245.28 105.36 1149.47 406.99 742.48 0.00 0.00
July 1197.72 123.96 1065.43 385.55 679.88 0.00 0.00
August 1082.59 207.16 993.05 456.24 536.81 0.00 0.00
September 709.71 416.69 745.61 384.10 361.51 0.00 0.00
October 379.34 755.53 524.97 300.81 224.16 0.00 0.00
November 106.72 1330.56 272.77 180.95 91.82 0.00 0.00
December 1.87 1590.33 47.93 32.00 15.93 0.00 0.00
               
Annual Sum or Average 693.15 729.38 740.02 363.86 376.16 0.00 0.00
Minimum of Months 1.87 105.36 47.93 32.00 15.93 0.00 0.00
Maximum of Months 1245.28 1590.33 1244.79 671.66 742.48 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.320012E+09 0.293825E+10 0.559203E+09 0.371266E+09 0.187937E+09 0.00 0.00
February 0.139712E+10 0.212711E+10 0.168806E+10 0.116947E+10 0.518598E+09 0.00 0.00
March 0.306028E+10 0.180415E+10 0.316934E+10 0.214069E+10 0.102865E+10 0.00 0.00
April 0.406070E+10 0.111054E+10 0.376473E+10 0.234050E+10 0.142424E+10 0.00 0.00
May 0.361792E+10 0.556942E+09 0.322150E+10 0.167417E+10 0.154734E+10 0.00 0.00
June 0.330520E+10 0.252833E+09 0.283600E+10 0.116157E+10 0.167442E+10 0.00 0.00
July 0.336837E+10 0.273248E+09 0.281692E+10 0.122228E+10 0.159464E+10 0.00 0.00
August 0.341882E+10 0.437734E+09 0.292710E+10 0.161383E+10 0.131327E+10 0.00 0.00
September 0.238131E+10 0.828978E+09 0.225796E+10 0.134752E+10 0.910433E+09 0.00 0.00
October 0.154736E+10 0.153170E+10 0.172479E+10 0.109153E+10 0.633259E+09 0.00 0.00
November 0.579560E+09 0.264822E+10 0.903765E+09 0.635430E+09 0.268335E+09 0.00 0.00
December 29331857.35 0.326573E+10 0.165135E+09 0.116113E+09 49022045.21 0.00 0.00
               
Annual Sum or Average 0.270860E+11 0.177754E+11 0.260345E+11 0.148844E+11 0.111501E+11 0.00 0.00
Minimum of Months 29331857.35 0.252833E+09 0.165135E+09 0.116113E+09 49022045.21 0.00 0.00
Maximum of Months 0.406070E+10 0.326573E+10 0.376473E+10 0.234050E+10 0.167442E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.894315E+09 0.824967E+10 0.157468E+10 0.104546E+10 0.529219E+09 0.00 0.00
February 0.390855E+10 0.597438E+10 0.475348E+10 0.329314E+10 0.146034E+10 0.00 0.00
March 0.856059E+10 0.509598E+10 0.892466E+10 0.602805E+10 0.289661E+10 0.00 0.00
April 0.113647E+11 0.321309E+10 0.106012E+11 0.659068E+10 0.401055E+10 0.00 0.00
May 0.100857E+11 0.168025E+10 0.907154E+10 0.471435E+10 0.435719E+10 0.00 0.00
June 0.919621E+10 0.790307E+09 0.798599E+10 0.327092E+10 0.471507E+10 0.00 0.00
July 0.937496E+10 0.851905E+09 0.793227E+10 0.344187E+10 0.449040E+10 0.00 0.00
August 0.953906E+10 0.133918E+10 0.824253E+10 0.454444E+10 0.369809E+10 0.00 0.00
September 0.664398E+10 0.243455E+10 0.635826E+10 0.379454E+10 0.256372E+10 0.00 0.00
October 0.431880E+10 0.434383E+10 0.485689E+10 0.307367E+10 0.178321E+10 0.00 0.00
November 0.161851E+10 0.743029E+10 0.254494E+10 0.178933E+10 0.755614E+09 0.00 0.00
December 81482475.74 0.916002E+10 0.465010E+09 0.326967E+09 0.138043E+09 0.00 0.00
               
Annual Sum or Average 0.755868E+11 0.505634E+11 0.733115E+11 0.419134E+11 0.313981E+11 0.00 0.00
Minimum of Months 81482475.74 0.790307E+09 0.465010E+09 0.326967E+09 0.138043E+09 0.00 0.00
Maximum of Months 0.113647E+11 0.916002E+10 0.106012E+11 0.659068E+10 0.471507E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.115864E+10 0.111511E+11 0.204560E+10 0.135811E+10 0.687486E+09 0.00 0.00
February 0.511675E+10 0.806096E+10 0.617504E+10 0.427797E+10 0.189706E+10 0.00 0.00
March 0.112812E+11 0.687721E+10 0.115936E+11 0.783078E+10 0.376286E+10 0.00 0.00
April 0.149724E+11 0.435979E+10 0.137716E+11 0.856167E+10 0.520994E+10 0.00 0.00
May 0.132509E+11 0.232583E+10 0.117845E+11 0.612421E+10 0.566024E+10 0.00 0.00
June 0.120657E+11 0.110591E+10 0.103742E+11 0.424911E+10 0.612514E+10 0.00 0.00
July 0.122857E+11 0.119908E+10 0.103045E+11 0.447118E+10 0.583329E+10 0.00 0.00
August 0.124957E+11 0.187352E+10 0.107075E+11 0.590348E+10 0.480403E+10 0.00 0.00
September 0.869235E+10 0.340541E+10 0.825974E+10 0.492932E+10 0.333042E+10 0.00 0.00
October 0.564541E+10 0.597408E+10 0.630937E+10 0.399287E+10 0.231650E+10 0.00 0.00
November 0.210422E+10 0.100397E+11 0.330602E+10 0.232444E+10 0.981585E+09 0.00 0.00
December 0.103304E+09 0.123535E+11 0.604074E+09 0.424749E+09 0.179326E+09 0.00 0.00
               
Annual Sum or Average 0.991723E+11 0.687261E+11 0.952358E+11 0.544479E+11 0.407879E+11 0.00 0.00
Minimum of Months 0.103304E+09 0.110591E+10 0.604074E+09 0.424749E+09 0.179326E+09 0.00 0.00
Maximum of Months 0.149724E+11 0.123535E+11 0.137716E+11 0.856167E+10 0.612514E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 18707304.14 0.175567E+10 0.133591E+09 77445703.38 56145697.68 0.00 0.00
February 0.212866E+09 0.126085E+10 0.457436E+09 0.274644E+09 0.182791E+09 0.00 0.00
March 0.785246E+09 0.104539E+10 0.103721E+10 0.600766E+09 0.436441E+09 0.00 0.00
April 0.167491E+10 0.606412E+09 0.168374E+10 0.949838E+09 0.733903E+09 0.00 0.00
May 0.167157E+10 0.295071E+09 0.157849E+10 0.759807E+09 0.818685E+09 0.00 0.00
June 0.177187E+10 0.128754E+09 0.155887E+10 0.655002E+09 0.903870E+09 0.00 0.00
July 0.164907E+10 0.142084E+09 0.141886E+10 0.566781E+09 0.852076E+09 0.00 0.00
August 0.143852E+10 0.234565E+09 0.128999E+10 0.621133E+09 0.668855E+09 0.00 0.00
September 0.811064E+09 0.468155E+09 0.860783E+09 0.439074E+09 0.421709E+09 0.00 0.00
October 0.317760E+09 0.898516E+09 0.509379E+09 0.266528E+09 0.242851E+09 0.00 0.00
November 66986757.61 0.157659E+10 0.244790E+09 0.150130E+09 94660161.76 0.00 0.00
December 0.00 0.192467E+10 38702614.64 23604172.24 15098442.40 0.00 0.00
               
Annual Sum or Average 0.104186E+11 0.103367E+11 0.108118E+11 0.538475E+10 0.542709E+10 0.00 0.00
Minimum of Months 0.00 0.128754E+09 38702614.64 23604172.24 15098442.40 0.00 0.00
Maximum of Months 0.177187E+10 0.192467E+10 0.168374E+10 0.949838E+09 0.903870E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.186666E+10 31930642.28 4040088.38 27890553.90 0.00 0.00
February 13589176.71 0.143934E+10 0.159225E+09 43420979.82 0.115804E+09 0.00 0.00
March 0.227313E+09 0.114337E+10 0.516001E+09 0.177535E+09 0.338466E+09 0.00 0.00
April 0.972351E+09 0.605061E+09 0.112592E+10 0.492636E+09 0.633285E+09 0.00 0.00
May 0.119090E+10 0.251973E+09 0.123663E+10 0.476734E+09 0.759897E+09 0.00 0.00
June 0.149282E+10 0.100246E+09 0.136741E+10 0.507653E+09 0.859760E+09 0.00 0.00
July 0.132355E+10 0.122065E+09 0.118461E+10 0.379479E+09 0.805134E+09 0.00 0.00
August 0.947071E+09 0.216076E+09 0.919284E+09 0.314874E+09 0.604411E+09 0.00 0.00
September 0.398190E+09 0.473737E+09 0.525170E+09 0.173033E+09 0.352137E+09 0.00 0.00
October 62580360.24 0.998689E+09 0.223765E+09 50713878.96 0.173051E+09 0.00 0.00
November 2875034.43 0.171700E+10 82739860.71 24494500.61 58245360.10 0.00 0.00
December 0.00 0.196161E+10 8753340.04 646601.17 8106738.86 0.00 0.00
               
Annual Sum or Average 0.663124E+10 0.108958E+11 0.738145E+10 0.264526E+10 0.473619E+10 0.00 0.00
Minimum of Months 0.00 0.100246E+09 8753340.04 646601.17 8106738.86 0.00 0.00
Maximum of Months 0.149282E+10 0.196161E+10 0.136741E+10 0.507653E+09 0.859760E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 51648481.22 0.460559E+09 88433712.47 58712815.60 29720896.87 0.00 0.00
February 0.224581E+09 0.332686E+09 0.266954E+09 0.184942E+09 82012514.30 0.00 0.00
March 0.487695E+09 0.288102E+09 0.501208E+09 0.338534E+09 0.162674E+09 0.00 0.00
April 0.640456E+09 0.189850E+09 0.595365E+09 0.370131E+09 0.225234E+09 0.00 0.00
May 0.566918E+09 0.100534E+09 0.509458E+09 0.264757E+09 0.244701E+09 0.00 0.00
June 0.517800E+09 47026533.21 0.448493E+09 0.183694E+09 0.264799E+09 0.00 0.00
July 0.528330E+09 50803746.01 0.445476E+09 0.193294E+09 0.252182E+09 0.00 0.00
August 0.536654E+09 80252730.27 0.462900E+09 0.255215E+09 0.207685E+09 0.00 0.00
September 0.374026E+09 0.143664E+09 0.357079E+09 0.213101E+09 0.143979E+09 0.00 0.00
October 0.246175E+09 0.243265E+09 0.272762E+09 0.172617E+09 0.100145E+09 0.00 0.00
November 94313248.80 0.411418E+09 0.142924E+09 0.100488E+09 42435206.82 0.00 0.00
December 4847111.02 0.511788E+09 26114876.87 18362405.06 7752471.81 0.00 0.00
               
Annual Sum or Average 0.427344E+10 0.285995E+10 0.411717E+10 0.235385E+10 0.176332E+10 0.00 0.00
Minimum of Months 4847111.02 47026533.21 26114876.87 18362405.06 7752471.81 0.00 0.00
Maximum of Months 0.640456E+09 0.511788E+09 0.595365E+09 0.370131E+09 0.264799E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.536275E+09 7123636.68 0.00 7123636.68 0.00 0.00
February 0.00 0.430700E+09 28442517.75 0.00 28442517.75 0.00 0.00
March 7569515.52 0.352189E+09 84353997.24 16617.43 84337379.81 0.00 0.00
April 66131657.10 0.174998E+09 0.149248E+09 4444402.57 0.144804E+09 0.00 0.00
May 0.200940E+09 69014504.24 0.236102E+09 38355563.63 0.197746E+09 0.00 0.00
June 0.315400E+09 25469982.24 0.295454E+09 65859883.80 0.229594E+09 0.00 0.00
July 0.284967E+09 31495630.49 0.258205E+09 43497207.92 0.214707E+09 0.00 0.00
August 0.154711E+09 58855636.77 0.166451E+09 10259358.32 0.156192E+09 0.00 0.00
September 39419964.43 0.139252E+09 88671519.31 310369.43 88361149.88 0.00 0.00
October 3542928.45 0.299812E+09 44330617.62 0.00 44330617.62 0.00 0.00
November 0.00 0.504155E+09 13313569.27 0.00 13313569.27 0.00 0.00
December 0.00 0.560577E+09 2160937.14 0.00 2160937.14 0.00 0.00
               
Annual Sum or Average 0.107268E+10 0.318280E+10 0.137386E+10 0.162743E+09 0.121111E+10 0.00 0.00
Minimum of Months 0.00 25469982.24 2160937.14 0.00 2160937.14 0.00 0.00
Maximum of Months 0.315400E+09 0.560577E+09 0.295454E+09 65859883.80 0.229594E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 39716335.82 0.174199E+10 0.160144E+09 91986738.46 68156849.82 0.00 0.00
February 0.340685E+09 0.125034E+10 0.564781E+09 0.342172E+09 0.222609E+09 0.00 0.00
March 0.115498E+10 0.103984E+10 0.134206E+10 0.785097E+09 0.556962E+09 0.00 0.00
April 0.161936E+10 0.576083E+09 0.166520E+10 0.928573E+09 0.736627E+09 0.00 0.00
May 0.221092E+10 0.274845E+09 0.202102E+10 0.111073E+10 0.910290E+09 0.00 0.00
June 0.205151E+10 0.111769E+09 0.178816E+10 0.801641E+09 0.986519E+09 0.00 0.00
July 0.208054E+10 0.130293E+09 0.176482E+10 0.827723E+09 0.937098E+09 0.00 0.00
August 0.175517E+10 0.222447E+09 0.154952E+10 0.793927E+09 0.755597E+09 0.00 0.00
September 0.101439E+10 0.457702E+09 0.103480E+10 0.532172E+09 0.502627E+09 0.00 0.00
October 0.516172E+09 0.896575E+09 0.670754E+09 0.349433E+09 0.321321E+09 0.00 0.00
November 63080382.88 0.157112E+10 0.245253E+09 0.150083E+09 95169677.68 0.00 0.00
December 6851.72 0.191871E+10 42484771.30 25367270.14 17117501.16 0.00 0.00
               
Annual Sum or Average 0.128465E+11 0.101917E+11 0.128490E+11 0.673891E+10 0.611009E+10 0.00 0.00
Minimum of Months 6851.72 0.111769E+09 42484771.30 25367270.14 17117501.16 0.00 0.00
Maximum of Months 0.221092E+10 0.191871E+10 0.202102E+10 0.111073E+10 0.986519E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 2518947.19 0.183182E+10 58482829.51 18581123.47 39901706.04 0.00 0.00
February 85226140.47 0.136658E+10 0.266570E+09 0.110948E+09 0.155622E+09 0.00 0.00
March 0.568052E+09 0.110015E+10 0.820853E+09 0.361866E+09 0.458987E+09 0.00 0.00
April 0.906660E+09 0.567415E+09 0.110738E+10 0.471372E+09 0.636010E+09 0.00 0.00
May 0.174990E+10 0.260513E+09 0.167916E+10 0.827661E+09 0.851502E+09 0.00 0.00
June 0.178327E+10 0.100865E+09 0.159670E+10 0.654291E+09 0.942409E+09 0.00 0.00
July 0.176185E+10 0.122544E+09 0.153058E+10 0.640422E+09 0.890157E+09 0.00 0.00
August 0.127207E+10 0.217266E+09 0.117882E+10 0.487668E+09 0.691152E+09 0.00 0.00
September 0.595317E+09 0.460108E+09 0.699186E+09 0.266131E+09 0.433055E+09 0.00 0.00
October 0.218095E+09 0.949101E+09 0.385139E+09 0.133619E+09 0.251521E+09 0.00 0.00
November 1701773.21 0.171426E+10 83202599.87 24447723.86 58754876.02 0.00 0.00
December 0.00 0.195512E+10 12535496.69 2409699.07 10125797.62 0.00 0.00
               
Annual Sum or Average 0.894465E+10 0.106457E+11 0.941861E+10 0.399942E+10 0.541920E+10 0.00 0.00
Minimum of Months 0.00 0.100865E+09 12535496.69 2409699.07 10125797.62 0.00 0.00
Maximum of Months 0.178327E+10 0.195512E+10 0.167916E+10 0.827661E+09 0.942409E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 49867537.02 0.220452E+10 0.207043E+09 0.127214E+09 79829104.17 0.00 0.00
February 0.338952E+09 0.159063E+10 0.640032E+09 0.400718E+09 0.239314E+09 0.00 0.00
March 0.966768E+09 0.133493E+10 0.126872E+10 0.733545E+09 0.535172E+09 0.00 0.00
April 0.152035E+10 0.781142E+09 0.161331E+10 0.811600E+09 0.801712E+09 0.00 0.00
May 0.161840E+10 0.350736E+09 0.161533E+10 0.656746E+09 0.958584E+09 0.00 0.00
June 0.174998E+10 0.148606E+09 0.161181E+10 0.540689E+09 0.107112E+10 0.00 0.00
July 0.171858E+10 0.181161E+09 0.152458E+10 0.513045E+09 0.101154E+10 0.00 0.00
August 0.147133E+10 0.308312E+09 0.136357E+10 0.575204E+09 0.788361E+09 0.00 0.00
September 0.885673E+09 0.610408E+09 0.965784E+09 0.462402E+09 0.503382E+09 0.00 0.00
October 0.453333E+09 0.114134E+10 0.687035E+09 0.374012E+09 0.313022E+09 0.00 0.00
November 0.102127E+09 0.198108E+10 0.338517E+09 0.217730E+09 0.120787E+09 0.00 0.00
December 521925.33 0.242259E+10 61264990.33 39786225.36 21478764.97 0.00 0.00
               
Annual Sum or Average 0.108759E+11 0.130555E+11 0.118970E+11 0.545269E+10 0.644430E+10 0.00 0.00
Minimum of Months 521925.33 0.148606E+09 61264990.33 39786225.36 21478764.97 0.00 0.00
Maximum of Months 0.174998E+10 0.242259E+10 0.161533E+10 0.811600E+09 0.107112E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 19106438.04 0.174497E+10 0.133591E+09 77445703.38 56145697.68 0.00 0.00
February 0.214949E+09 0.125282E+10 0.457436E+09 0.274644E+09 0.182791E+09 0.00 0.00
March 0.787627E+09 0.104115E+10 0.103721E+10 0.600766E+09 0.436441E+09 0.00 0.00
April 0.167105E+10 0.603429E+09 0.168374E+10 0.949838E+09 0.733903E+09 0.00 0.00
May 0.166720E+10 0.291539E+09 0.157849E+10 0.759807E+09 0.818685E+09 0.00 0.00
June 0.176574E+10 0.126383E+09 0.155887E+10 0.655002E+09 0.903870E+09 0.00 0.00
July 0.164381E+10 0.139422E+09 0.141886E+10 0.566781E+09 0.852076E+09 0.00 0.00
August 0.143546E+10 0.230709E+09 0.128999E+10 0.621133E+09 0.668855E+09 0.00 0.00
September 0.813484E+09 0.461654E+09 0.860783E+09 0.439074E+09 0.421709E+09 0.00 0.00
October 0.320340E+09 0.893052E+09 0.509379E+09 0.266528E+09 0.242851E+09 0.00 0.00
November 68344722.48 0.156120E+10 0.244790E+09 0.150130E+09 94660161.76 0.00 0.00
December 0.00 0.191301E+10 38702614.64 23604172.24 15098442.40 0.00 0.00
               
Annual Sum or Average 0.104071E+11 0.102593E+11 0.108118E+11 0.538475E+10 0.542709E+10 0.00 0.00
Minimum of Months 0.00 0.126383E+09 38702614.64 23604172.24 15098442.40 0.00 0.00
Maximum of Months 0.176574E+10 0.191301E+10 0.168374E+10 0.949838E+09 0.903870E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.185594E+10 31930642.28 4040088.38 27890553.90 0.00 0.00
February 13971507.51 0.143035E+10 0.159225E+09 43420979.82 0.115804E+09 0.00 0.00
March 0.228218E+09 0.113873E+10 0.516001E+09 0.177535E+09 0.338466E+09 0.00 0.00
April 0.972087E+09 0.601725E+09 0.112592E+10 0.492636E+09 0.633285E+09 0.00 0.00
May 0.119146E+10 0.248971E+09 0.123663E+10 0.476734E+09 0.759897E+09 0.00 0.00
June 0.148942E+10 98506145.16 0.136741E+10 0.507653E+09 0.859760E+09 0.00 0.00
July 0.132080E+10 0.119839E+09 0.118461E+10 0.379479E+09 0.805134E+09 0.00 0.00
August 0.947516E+09 0.211994E+09 0.919284E+09 0.314874E+09 0.604411E+09 0.00 0.00
September 0.402643E+09 0.465870E+09 0.525170E+09 0.173033E+09 0.352137E+09 0.00 0.00
October 64256322.48 0.992629E+09 0.223765E+09 50713878.96 0.173051E+09 0.00 0.00
November 2982916.32 0.170074E+10 82739860.71 24494500.61 58245360.10 0.00 0.00
December 0.00 0.195001E+10 8753340.04 646601.17 8106738.86 0.00 0.00
               
Annual Sum or Average 0.663335E+10 0.108153E+11 0.738145E+10 0.264526E+10 0.473619E+10 0.00 0.00
Minimum of Months 0.00 98506145.16 8753340.04 646601.17 8106738.86 0.00 0.00
Maximum of Months 0.148942E+10 0.195001E+10 0.136741E+10 0.507653E+09 0.859760E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 92489239.87 0.871739E+09 0.162153E+09 0.107656E+09 54496520.21 0.00 0.00
February 0.402646E+09 0.633615E+09 0.489490E+09 0.339111E+09 0.150379E+09 0.00 0.00
March 0.879457E+09 0.543273E+09 0.919020E+09 0.620739E+09 0.298280E+09 0.00 0.00
April 0.117069E+10 0.331140E+09 0.109167E+10 0.678677E+09 0.412990E+09 0.00 0.00
May 0.104392E+10 0.161442E+09 0.934147E+09 0.485461E+09 0.448686E+09 0.00 0.00
June 0.958932E+09 68503096.75 0.822362E+09 0.336823E+09 0.485539E+09 0.00 0.00
July 0.978172E+09 74381275.76 0.816830E+09 0.354427E+09 0.462403E+09 0.00 0.00
August 0.990134E+09 0.123638E+09 0.848778E+09 0.467964E+09 0.380814E+09 0.00 0.00
September 0.687752E+09 0.245241E+09 0.654744E+09 0.390743E+09 0.264001E+09 0.00 0.00
October 0.444166E+09 0.457972E+09 0.500139E+09 0.316512E+09 0.183627E+09 0.00 0.00
November 0.169667E+09 0.777988E+09 0.262066E+09 0.184256E+09 77809600.31 0.00 0.00
December 8702535.85 0.965255E+09 47884487.52 33669481.21 14215006.31 0.00 0.00
               
Annual Sum or Average 0.782673E+10 0.525419E+10 0.754928E+10 0.431604E+10 0.323324E+10 0.00 0.00
Minimum of Months 8702535.85 68503096.75 47884487.52 33669481.21 14215006.31 0.00 0.00
Maximum of Months 0.117069E+10 0.965255E+09 0.109167E+10 0.678677E+09 0.485539E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.485571E+10 62321199.25 0.00 62321199.25 0.00 0.00
February 0.00 0.393402E+10 0.248830E+09 0.00 0.248830E+09 0.00 0.00
March 43996759.36 0.332006E+10 0.737972E+09 145377.71 0.737826E+09 0.00 0.00
April 0.471768E+09 0.172430E+10 0.130570E+10 38881895.68 0.126682E+10 0.00 0.00
May 0.157046E+10 0.702899E+09 0.206554E+10 0.335554E+09 0.172998E+10 0.00 0.00
June 0.256916E+10 0.284831E+09 0.258478E+10 0.576176E+09 0.200861E+10 0.00 0.00
July 0.231143E+10 0.350726E+09 0.225891E+10 0.380536E+09 0.187837E+10 0.00 0.00
August 0.119721E+10 0.627359E+09 0.145620E+10 89754088.05 0.136645E+10 0.00 0.00
September 0.269364E+09 0.141283E+10 0.775744E+09 2715269.72 0.773028E+09 0.00 0.00
October 16542117.31 0.289702E+10 0.387827E+09 0.00 0.387827E+09 0.00 0.00
November 0.00 0.455349E+10 0.116474E+09 0.00 0.116474E+09 0.00 0.00
December 0.00 0.504166E+10 18904977.91 0.00 18904977.91 0.00 0.00
               
Annual Sum or Average 0.844993E+10 0.297049E+11 0.120192E+11 0.142376E+10 0.105954E+11 0.00 0.00
Minimum of Months 0.00 0.284831E+09 18904977.91 0.00 18904977.91 0.00 0.00
Maximum of Months 0.256916E+10 0.504166E+10 0.258478E+10 0.576176E+09 0.200861E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.493390E+10 62321199.25 0.00 62321199.25 0.00 0.00
February 0.00 0.400336E+10 0.248830E+09 0.00 0.248830E+09 0.00 0.00
March 38422877.93 0.338846E+10 0.737972E+09 145377.71 0.737826E+09 0.00 0.00
April 0.450466E+09 0.176006E+10 0.130570E+10 38881895.68 0.126682E+10 0.00 0.00
May 0.154242E+10 0.715623E+09 0.206554E+10 0.335554E+09 0.172998E+10 0.00 0.00
June 0.254702E+10 0.291304E+09 0.258478E+10 0.576176E+09 0.200861E+10 0.00 0.00
July 0.229013E+10 0.358790E+09 0.225891E+10 0.380536E+09 0.187837E+10 0.00 0.00
August 0.117543E+10 0.641497E+09 0.145620E+10 89754088.05 0.136645E+10 0.00 0.00
September 0.253896E+09 0.144957E+10 0.775744E+09 2715269.72 0.773028E+09 0.00 0.00
October 13363151.66 0.296568E+10 0.387827E+09 0.00 0.387827E+09 0.00 0.00
November 0.00 0.463025E+10 0.116474E+09 0.00 0.116474E+09 0.00 0.00
December 0.00 0.511783E+10 18904977.91 0.00 18904977.91 0.00 0.00
               
Annual Sum or Average 0.831115E+10 0.302563E+11 0.120192E+11 0.142376E+10 0.105954E+11 0.00 0.00
Minimum of Months 0.00 0.291304E+09 18904977.91 0.00 18904977.91 0.00 0.00
Maximum of Months 0.254702E+10 0.511783E+10 0.258478E+10 0.576176E+09 0.200861E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 39775649.18 0.320090E+10 0.218619E+09 0.110565E+09 0.108054E+09 0.00 0.00
February 0.457513E+09 0.232039E+10 0.831319E+09 0.453105E+09 0.378214E+09 0.00 0.00
March 0.190132E+10 0.195173E+10 0.216281E+10 0.114691E+10 0.101590E+10 0.00 0.00
April 0.289456E+10 0.111374E+10 0.277245E+10 0.139988E+10 0.137257E+10 0.00 0.00
May 0.445977E+10 0.541557E+09 0.369999E+10 0.193828E+10 0.176171E+10 0.00 0.00
June 0.438687E+10 0.235960E+09 0.338469E+10 0.145585E+10 0.192883E+10 0.00 0.00
July 0.441973E+10 0.275496E+09 0.329523E+10 0.146806E+10 0.182717E+10 0.00 0.00
August 0.355383E+10 0.441558E+09 0.272821E+10 0.128153E+10 0.144668E+10 0.00 0.00
September 0.194691E+10 0.842232E+09 0.173390E+10 0.798265E+09 0.935636E+09 0.00 0.00
October 0.856594E+09 0.165035E+10 0.105585E+10 0.483033E+09 0.572814E+09 0.00 0.00
November 49277379.39 0.289364E+10 0.328446E+09 0.174527E+09 0.153919E+09 0.00 0.00
December 0.00 0.349495E+10 55018871.22 27776626.97 27242244.24 0.00 0.00
               
Annual Sum or Average 0.249662E+11 0.189625E+11 0.222665E+11 0.107378E+11 0.115287E+11 0.00 0.00
Minimum of Months 0.00 0.235960E+09 55018871.22 27776626.97 27242244.24 0.00 0.00
Maximum of Months 0.445977E+10 0.349495E+10 0.369999E+10 0.193828E+10 0.192883E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.139027E+09 0.386359E+10 0.434133E+09 0.274045E+09 0.160088E+09 0.00 0.00
February 0.824111E+09 0.278779E+10 0.133132E+10 0.863226E+09 0.468097E+09 0.00 0.00
March 0.212497E+10 0.235797E+10 0.259239E+10 0.158018E+10 0.101222E+10 0.00 0.00
April 0.315350E+10 0.139275E+10 0.322649E+10 0.174094E+10 0.148556E+10 0.00 0.00
May 0.314510E+10 0.627541E+09 0.308599E+10 0.135079E+10 0.173520E+10 0.00 0.00
June 0.322778E+10 0.273101E+09 0.297943E+10 0.105492E+10 0.192452E+10 0.00 0.00
July 0.320796E+10 0.332017E+09 0.285364E+10 0.103266E+10 0.182098E+10 0.00 0.00
August 0.289961E+10 0.554858E+09 0.265980E+10 0.122199E+10 0.143780E+10 0.00 0.00
September 0.183958E+10 0.108005E+10 0.193261E+10 0.995589E+09 0.937024E+09 0.00 0.00
October 0.101603E+10 0.202361E+10 0.140608E+10 0.805697E+09 0.600381E+09 0.00 0.00
November 0.276612E+09 0.344881E+10 0.707030E+09 0.469034E+09 0.237996E+09 0.00 0.00
December 4999348.11 0.425954E+10 0.128373E+09 85707453.80 42665717.39 0.00 0.00
               
Annual Sum or Average 0.218593E+11 0.230016E+11 0.233373E+11 0.114748E+11 0.118625E+11 0.00 0.00
Minimum of Months 4999348.11 0.273101E+09 0.128373E+09 85707453.80 42665717.39 0.00 0.00
Maximum of Months 0.322778E+10 0.425954E+10 0.322649E+10 0.174094E+10 0.192452E+10 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January -17.6 -17.9 -19.9 1.62 -32.2 4.20 17.57 0.00
February -15.4 -16.0 -18.9 1.58 -31.2 17.68 68.90 0.00
March -10.3 -11.6 -17.1 2.46 -25.4 47.11 147.56 0.00
April 0.73 -2.7 -8.8 3.74 -14.2 75.81 230.75 0.00
May 10.60 5.25 -1.5 3.99 -2.1 92.54 252.99 0.00
June 15.96 10.88 6.41 3.45 5.66 116.77 222.76 0.00
July 16.86 12.85 9.90 2.85 7.58 107.92 197.90 0.00
August 14.24 10.70 7.59 2.94 4.33 81.01 176.65 0.00
September 6.72 4.45 1.76 2.11 -4.1 51.38 110.92 0.00
October -3.1 -4.4 -7.1 2.79 -14.3 26.50 62.95 0.00
November -17.6 -18.1 -20.3 0.70 -32.8 8.03 31.72 0.00
December -19.3 -19.6 -21.9 1.25 -33.6 1.27 5.23 0.00
                 
Annual Sum or Average -1.4 -3.8 -7.4 2.46 -14.3 52.69 127.40 0.00
Minimum of Months -19.3 -19.6 -21.9 0.70 -33.6 1.27 5.23 0.00
Maximum of Months 16.86 12.85 9.90 3.99 7.58 116.77 252.99 0.00



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -1.1 21-JAN-20:00 -2.7 -5.6 0.00 -9.0 0.00 0.00
February 2.80 08-FEB-15:09 -0.7 -6.5 2.68 -7.9 21.67 32.33
March 6.70 20-MAR-14:09 2.60 -3.5 1.37 -7.5 138.33 487.67
April 15.60 22-APR-13:00 7.03 -3.3 4.10 -0.8 117.50 760.50
May 22.20 31-MAY-15:00 10.79 -1.1 3.10 7.75 143.50 516.50
June 28.30 30-JUN-14:00 17.30 10.60 6.20 17.57 223.50 277.50
July 30.00 29-JUL-16:19 18.34 11.70 4.67 18.88 163.67 322.83
August 25.60 11-AUG-15:00 14.77 6.70 6.20 12.22 99.50 604.00
September 17.20 07-SEP-15:00 8.91 0.00 1.50 2.64 77.00 480.50
October 13.90 01-OCT-14:00 8.01 1.70 2.60 1.58 78.50 227.50
November -3.9 18-NOV-03:00 -5.6 -8.9 1.50 -12.4 0.00 0.00
December 1.70 24-DEC-11:00 -0.1 -2.8 2.60 -8.8 13.50 31.50
                 
Annual Sum or Average                
Minimum of Months -3.9   -5.6 -8.9 0.00 -12.4 0.00 0.00
Maximum of Months 30.00   18.34 11.70 6.20 18.88 223.50 760.50



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -38.3 12-JAN-05:00 -38.4 -40.4 0.00 -60.9 0.00 0.00
February -36.1 27-FEB-04:00 -36.2 -39.4 0.00 -58.7 0.00 0.00
March -28.9 01-MAR-00:10 -29.2 -34.0 0.65 -51.0 0.00 0.00
April -21.7 03-APR-05:00 -22.3 -27.2 2.60 -42.7 0.00 0.00
May 0.00 27-MAY-03:00 -1.1 -2.8 6.20 -7.1 29.00 14.00
June 3.30 02-JUN-03:00 2.38 1.10 1.50 -11.2 45.50 266.00
July 7.20 31-JUL-03:49 6.67 6.10 2.18 -7.6 0.00 0.00
August -1.7 31-AUG-05:00 -2.9 -5.0 2.60 -18.6 25.00 538.50
September -5.6 29-SEP-06:00 -6.1 -7.2 2.60 -21.6 0.00 0.00
October -20.6 22-OCT-05:00 -20.8 -22.2 2.60 -40.2 0.00 0.00
November -30.0 29-NOV-09:00 -30.2 -33.3 0.00 -51.8 0.00 0.00
December -33.9 15-DEC-07:00 -34.0 -37.8 0.00 -56.5 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -38.3   -38.4 -40.4 0.00 -60.9 0.00 0.00
Maximum of Months 7.20   6.67 6.10 6.20 -7.1 45.50 538.50



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -2.7 21-JAN-20:00 -1.1 -5.6 0.00 -9.0 0.00 0.00
February 1.24 09-FEB-01:00 2.80 -1.1 8.80 -4.1 0.00 0.00
March 2.65 20-MAR-13:00 6.70 -3.3 0.00 -7.6 139.00 515.00
April 7.03 22-APR-13:00 15.60 -3.3 4.10 -0.8 117.50 760.50
May 10.97 31-MAY-17:00 21.70 0.00 2.60 11.07 73.50 187.00
June 18.33 30-JUN-11:00 25.60 14.40 1.50 15.21 221.00 616.00
July 18.36 29-JUL-17:19 29.07 12.23 3.10 19.29 141.00 225.33
August 16.14 04-AUG-19:00 21.70 12.80 3.10 14.28 25.50 28.50
September 10.82 01-SEP-15:00 15.60 6.70 2.60 4.31 145.50 176.00
October 8.01 01-OCT-14:00 13.90 1.70 2.60 1.58 78.50 227.50
November -5.6 18-NOV-03:00 -3.9 -8.9 1.50 -12.4 0.00 0.00
December -0.1 24-DEC-11:00 1.70 -2.8 2.60 -8.8 13.50 31.50
                 
Annual Sum or Average                
Minimum of Months -5.6   -3.9 -8.9 0.00 -12.4 0.00 0.00
Maximum of Months 18.36   29.07 14.40 8.80 19.29 221.00 760.50



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -4.4 06-JAN-19:00 -1.7 -2.7 2.60 -12.4 0.00 0.00
February -0.6 09-FEB-00:00 1.70 0.78 3.60 -5.0 0.00 0.00
March 0.00 21-MAR-15:00 1.10 0.62 2.10 -5.5 70.50 4.00
April 0.00 30-APR-07:00 3.30 1.91 2.60 -8.3 198.00 170.00
May 6.10 16-MAY-19:00 8.90 7.49 5.20 3.69 16.00 15.00
June 15.60 30-JUN-17:00 18.90 16.75 3.60 12.22 99.50 223.00
July 17.80 03-JUL-14:00 19.40 18.27 1.50 10.11 223.00 401.50
August 15.00 12-AUG-22:00 16.10 15.38 0.00 12.79 0.00 0.00
September 8.90 04-SEP-11:00 10.00 9.41 2.60 5.33 238.50 0.50
October 5.60 02-OCT-11:09 7.30 6.41 4.95 0.30 123.67 16.00
November -8.3 18-NOV-04:00 -5.0 -6.1 1.50 -13.4 0.00 0.00
December -2.8 24-DEC-09:00 1.10 -0.5 3.10 -6.2 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -8.3   -5.0 -6.1 0.00 -13.4 0.00 0.00
Maximum of Months 17.80   19.40 18.27 5.20 12.79 238.50 401.50



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 0.00 1.10 0.00
February 18.00 13.00 16.00 0.00 5.89 0.00
March 18.00 13.00 16.00 0.00 18.25 0.00
April 18.00 13.00 16.00 0.00 35.02 0.00
May 18.00 13.00 16.00 0.44 43.39 0.00
June 18.00 13.00 16.00 2.62 46.67 0.00
July 18.00 13.00 16.00 4.74 42.09 0.00
August 18.00 13.00 16.00 6.08 32.30 0.00
September 18.00 13.00 16.00 6.25 18.21 0.00
October 18.00 13.00 16.00 5.21 8.04 0.00
November 18.00 13.00 16.00 3.27 2.12 0.00
December 18.00 13.00 16.00 0.94 0.28 0.00
             
Annual Sum or Average 18.00 13.00 16.00 2.48 21.19 0.00
Minimum of Months 18.00 13.00 16.00 0.00 0.28 0.00
Maximum of Months 18.00 13.00 16.00 6.25 46.67 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWH BOOSTER E WATER HEATER

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.770615E+10 -0.754278E+10 0.00 0.00 744.00 0.00 -163375025.3 81.21 0.00 0.00
February 0.696318E+10 -0.681597E+10 0.00 0.00 672.00 0.00 -147209883.0 81.21 0.00 0.00
March 0.770399E+10 -0.754146E+10 0.00 0.00 744.00 0.00 -162528474.4 81.21 0.00 0.00
April 0.746502E+10 -0.730860E+10 0.00 0.00 720.00 0.00 -156426647.2 81.21 0.00 0.00
May 0.770402E+10 -0.754279E+10 0.00 0.00 744.00 0.00 -161231774.6 81.21 0.00 0.00
June 0.745676E+10 -0.730053E+10 0.00 0.00 720.00 0.00 -156232126.2 81.21 0.00 0.00
July 0.771231E+10 -0.755084E+10 0.00 0.00 744.00 0.00 -161463153.4 81.21 0.00 0.00
August 0.770421E+10 -0.754280E+10 0.00 0.00 744.00 0.00 -161410873.7 81.21 0.00 0.00
September 0.746595E+10 -0.730993E+10 0.00 0.00 720.00 0.00 -156025140.3 81.21 0.00 0.00
October 0.770340E+10 -0.754143E+10 0.00 0.00 744.00 0.00 -161973130.7 81.21 0.00 0.00
November 0.745017E+10 -0.729243E+10 0.00 0.00 720.00 0.00 -157742712.3 81.21 0.00 0.00
December 0.771409E+10 -0.755084E+10 0.00 0.00 744.00 0.00 -163249288.4 81.21 0.00 0.00
                     
Annual Sum or Average 0.907493E+11 -0.888404E+11 0.00 0.00 8760.00 0.00 -0.190887E+10 81.21 0.00 0.00
Minimum of Months 0.696318E+10 -0.755084E+10 0.00 0.00 672.00 0.00 -163375025.3 81.21 0.00 0.00
Maximum of Months 0.771409E+10 -0.681597E+10 0.00 0.00 744.00 0.00 -147209883.0 81.21 0.00 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWH LAUNDRY G WATER HEATER

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.129580E+12 -0.127859E+12 0.00 0.00 744.00 0.00 -0.172053E+10 79.60 0.00 0.00
February 0.117053E+12 -0.115479E+12 0.00 0.00 672.00 0.00 -0.157421E+10 79.61 0.00 0.00
March 0.129597E+12 -0.127852E+12 0.00 0.00 744.00 0.00 -0.174500E+10 79.61 0.00 0.00
April 0.125408E+12 -0.123731E+12 0.00 0.00 720.00 0.00 -0.167693E+10 79.61 0.00 0.00
May 0.129519E+12 -0.127790E+12 0.00 0.00 744.00 0.00 -0.172939E+10 79.72 0.00 0.00
June 0.125035E+12 -0.123351E+12 0.00 0.00 720.00 0.00 -0.168353E+10 80.29 0.00 0.00
July 0.128883E+12 -0.127149E+12 0.00 0.00 744.00 0.00 -0.173414E+10 80.85 0.00 0.00
August 0.128678E+12 -0.126948E+12 0.00 0.00 744.00 0.00 -0.173003E+10 81.20 0.00 0.00
September 0.124501E+12 -0.122829E+12 0.00 0.00 720.00 0.00 -0.167190E+10 81.24 0.00 0.00
October 0.128800E+12 -0.127080E+12 0.00 0.00 744.00 0.00 -0.171973E+10 80.97 0.00 0.00
November 0.124921E+12 -0.123265E+12 0.00 0.00 720.00 0.00 -0.165581E+10 80.46 0.00 0.00
December 0.129433E+12 -0.127723E+12 0.00 0.00 744.00 0.00 -0.170961E+10 79.85 0.00 0.00
                     
Annual Sum or Average 0.152141E+13 -0.150106E+13 0.00 0.00 8760.00 0.00 -0.203508E+11 80.25 0.00 0.00
Minimum of Months 0.117053E+12 -0.127859E+12 0.00 0.00 672.00 0.00 -0.174500E+10 79.60 0.00 0.00
Maximum of Months 0.129597E+12 -0.115479E+12 0.00 0.00 744.00 0.00 -0.157421E+10 81.24 0.00 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.877206E+11 -0.861971E+11 0.00 0.00 744.00 0.00 -0.152352E+10 58.99 0.00 0.00
February 0.792751E+11 -0.778711E+11 0.00 0.00 672.00 0.00 -0.140404E+10 58.99 0.00 0.00
March 0.878322E+11 -0.862748E+11 0.00 0.00 744.00 0.00 -0.155742E+10 58.99 0.00 0.00
April 0.849371E+11 -0.834462E+11 0.00 0.00 720.00 0.00 -0.149090E+10 58.99 0.00 0.00
May 0.871252E+11 -0.855942E+11 0.00 0.00 744.00 0.00 -0.153097E+10 58.99 0.00 0.00
June 0.812540E+11 -0.797818E+11 0.00 0.00 720.00 0.00 -0.147213E+10 58.99 0.00 0.00
July 0.807572E+11 -0.792669E+11 0.00 0.00 744.00 0.00 -0.149035E+10 58.99 0.00 0.00
August 0.788541E+11 -0.773841E+11 0.00 0.00 744.00 0.00 -0.147002E+10 58.99 0.00 0.00
September 0.760288E+11 -0.746111E+11 0.00 0.00 720.00 0.00 -0.141762E+10 58.99 0.00 0.00
October 0.800370E+11 -0.785717E+11 0.00 0.00 744.00 0.00 -0.146527E+10 58.99 0.00 0.00
November 0.802175E+11 -0.787905E+11 0.00 0.00 720.00 0.00 -0.142695E+10 58.99 0.00 0.00
December 0.863169E+11 -0.848188E+11 0.00 0.00 744.00 0.00 -0.149808E+10 58.99 0.00 0.00
                     
Annual Sum or Average 0.990356E+12 -0.972608E+12 0.00 0.00 8760.00 0.00 -0.177473E+11 58.99 0.00 0.00
Minimum of Months 0.760288E+11 -0.862748E+11 0.00 0.00 672.00 0.00 -0.155742E+10 58.99 0.00 0.00
Maximum of Months 0.878322E+11 -0.746111E+11 0.00 0.00 744.00 0.00 -0.140404E+10 58.99 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: LOBBY_FLR_1_DAYLCTRL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 108.67 0.95 0.93 08-JAN-11:09 594.96 26.53 72.33 76.33 422.80 28.07 72.67 43.83
February 205.83 0.94 0.93 01-FEB-10:39 2221.33 35.27 190.33 183.50 1782.90 36.29 191.83 157.17
March 329.50 0.93 0.93 01-MAR-08:30 5260.04 33.44 284.00 308.50 2820.88 31.33 288.50 274.17
April 421.83 0.94 0.93 01-APR-07:10 7402.36 30.58 279.17 388.83 815.76 22.15 312.50 324.00
May 545.00 0.94 0.93 01-MAY-04:00 3321.02 21.78 215.83 459.33 602.38 20.83 339.50 367.67
June 583.50 0.94 0.93 01-JUN-04:10 1471.27 18.68 197.33 485.83 575.47 20.42 322.83 377.00
July 562.83 0.94 0.93 01-JUL-03:00 1825.21 19.33 178.50 481.50 586.48 20.52 326.50 372.67
August 467.17 0.94 0.93 01-AUG-04:49 5083.14 26.25 247.17 412.00 650.01 21.11 288.50 333.67
September 356.33 0.94 0.93 01-SEP-05:00 4315.01 31.09 280.00 325.67 1166.01 23.56 231.17 270.67
October 265.50 0.94 0.93 01-OCT-07:40 2338.33 33.01 241.83 240.00 1835.43 33.99 245.17 211.00
November 135.83 0.94 0.93 01-NOV-09:30 874.60 32.66 117.50 127.33 638.73 33.91 117.67 93.33
December 71.17 0.98 0.93 04-DEC-10:00 141.78 6.02 0.00 12.50 83.84 9.04 0.00 1.17
                         
Annual Sum or Average 4053.17 0.94     3388.79 25.83 2304.00 3501.33 981.92 24.06 2736.83 2826.33
Minimum of Months 71.17 0.93 0.93   141.78 6.02 0.00 12.50 83.84 9.04 0.00 1.17
Maximum of Months 583.50 0.98 0.93   7402.36 35.27 284.00 485.83 2820.88 36.29 339.50 377.00



Table of Contents

Report: DaylightingReportMonthly

For: CAFE_FLR_1_DAYLCTRL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 108.67 0.69 0.61 01-JAN-11:00 699.26 27.00 72.50 87.17 525.44 28.51 72.67 63.00
February 205.83 0.64 0.61 01-FEB-09:00 2501.88 35.40 190.33 190.33 2062.68 36.39 192.67 175.67
March 329.50 0.63 0.61 01-MAR-08:30 5681.28 33.62 287.67 314.67 3243.09 31.36 279.50 297.33
April 421.83 0.63 0.61 01-APR-06:00 7844.89 30.97 296.33 402.67 1256.71 22.16 311.00 364.83
May 545.00 0.64 0.61 01-MAY-04:49 3632.02 22.27 238.00 481.83 912.24 21.04 348.17 432.17
June 583.50 0.65 0.61 01-JUN-03:20 1734.86 19.22 204.67 514.67 838.02 20.79 355.33 449.67
July 562.83 0.64 0.61 01-JUL-03:30 2095.41 19.86 210.17 508.17 856.01 20.87 339.50 440.33
August 467.17 0.64 0.61 01-AUG-04:40 5406.99 26.77 274.00 431.00 973.25 21.33 292.50 387.00
September 356.33 0.64 0.61 01-SEP-05:49 4620.54 31.35 284.33 336.67 1468.91 23.81 241.33 302.17
October 265.50 0.63 0.61 01-OCT-07:30 2586.72 33.13 242.50 249.17 2081.84 34.10 247.33 229.50
November 135.83 0.65 0.61 01-NOV-09:20 1029.21 32.89 117.50 138.83 792.83 34.12 117.67 113.50
December 71.17 0.81 0.61 04-DEC-10:50 160.13 7.45 0.00 26.33 100.97 10.40 0.00 9.17
                         
Annual Sum or Average 4053.17 0.64     3689.38 26.24 2418.00 3681.50 1281.47 24.30 2797.67 3264.33
Minimum of Months 71.17 0.63 0.61   160.13 7.45 0.00 26.33 100.97 10.40 0.00 9.17
Maximum of Months 583.50 0.81 0.61   7844.89 35.40 296.33 514.67 3243.09 36.39 355.33 449.67



Table of Contents

Report: DaylightingReportMonthly

For: DINING_FLR_6_DAYLCTRL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 108.67 0.92 0.80 21-JAN-11:00 124.43 8.34 0.00 14.50 60.09 11.77 0.00 0.00
February 205.83 0.84 0.80 01-FEB-11:20 275.14 12.70 0.00 143.00 131.16 16.15 0.00 22.00
March 329.50 0.82 0.80 01-MAR-08:00 489.93 15.71 0.00 291.33 229.89 19.00 7.50 198.33
April 421.83 0.81 0.80 01-APR-06:00 620.36 17.85 10.17 408.17 308.17 21.10 98.83 351.83
May 545.00 0.81 0.80 01-MAY-04:40 785.18 19.89 89.00 505.83 376.85 23.39 246.33 472.00
June 583.50 0.81 0.80 01-JUN-02:00 978.52 21.42 149.33 548.17 458.17 23.67 332.33 505.83
July 562.83 0.81 0.80 01-JUL-02:00 883.09 20.67 126.17 537.17 396.21 22.91 269.67 478.17
August 467.17 0.81 0.80 01-AUG-04:30 661.15 18.13 35.33 438.83 315.15 21.64 118.00 365.33
September 356.33 0.82 0.80 01-SEP-05:49 480.58 15.59 0.00 319.50 218.40 18.76 11.17 203.33
October 265.50 0.83 0.80 01-OCT-07:40 342.72 13.68 0.00 215.00 149.82 16.93 0.00 29.17
November 135.83 0.89 0.80 01-NOV-09:50 168.61 10.28 0.00 47.83 79.39 13.97 0.00 0.00
December 71.17 0.99 0.93 04-DEC-10:50 45.77 3.54 0.00 0.00 22.81 6.59 0.00 0.00
                         
Annual Sum or Average 4053.17 0.82     638.13 17.40 410.00 3469.33 299.08 20.45 1083.83 2626.00
Minimum of Months 71.17 0.81 0.80   45.77 3.54 0.00 0.00 22.81 6.59 0.00 0.00
Maximum of Months 583.50 0.99 0.93   978.52 21.42 149.33 548.17 458.17 23.67 332.33 505.83



Table of Contents

Report: DaylightingReportMonthly

For: BANQUET_FLR_6_DAYLCTRL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 108.67 0.92 0.80 21-JAN-11:00 124.43 8.34 0.00 14.50 60.09 11.77 0.00 0.00
February 205.83 0.84 0.80 01-FEB-11:20 275.14 12.70 0.00 143.00 131.16 16.15 0.00 22.00
March 329.50 0.82 0.80 01-MAR-08:00 489.93 15.71 0.00 291.33 229.89 19.00 7.50 198.33
April 421.83 0.81 0.80 01-APR-06:00 620.36 17.85 10.17 408.17 308.17 21.10 98.83 351.83
May 545.00 0.81 0.80 01-MAY-04:40 785.18 19.89 89.00 505.83 376.85 23.39 246.33 472.00
June 583.50 0.81 0.80 01-JUN-02:00 978.52 21.42 149.33 548.17 458.17 23.67 332.33 505.83
July 562.83 0.81 0.80 01-JUL-02:00 883.09 20.67 126.17 537.17 396.21 22.91 269.67 478.17
August 467.17 0.81 0.80 01-AUG-04:30 661.15 18.13 35.33 438.83 315.15 21.64 118.00 365.33
September 356.33 0.82 0.80 01-SEP-05:49 480.58 15.59 0.00 319.50 218.40 18.76 11.17 203.33
October 265.50 0.83 0.80 01-OCT-07:40 342.72 13.68 0.00 215.00 149.82 16.93 0.00 29.17
November 135.83 0.89 0.80 01-NOV-09:50 168.61 10.28 0.00 47.83 79.39 13.97 0.00 0.00
December 71.17 0.99 0.93 04-DEC-10:50 45.77 3.54 0.00 0.00 22.81 6.59 0.00 0.00
                         
Annual Sum or Average 4053.17 0.82     638.13 17.40 410.00 3469.33 299.08 20.45 1083.83 2626.00
Minimum of Months 71.17 0.81 0.80   45.77 3.54 0.00 0.00 22.81 6.59 0.00 0.00
Maximum of Months 583.50 0.99 0.93   978.52 21.42 149.33 548.17 458.17 23.67 332.33 505.83



Table of Contents

Report: CoilReportMonthly

For: VAV WITH REHEAT HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.500879E+12 576535.23 12-JAN-10:00 0.00 0.00 0.00 0.00 0.00
February 0.428297E+12 568503.95 27-FEB-05:03 0.00 0.00 0.00 0.00 0.00
March 0.245426E+12 542748.74 01-MAR-00:07 0.00 0.00 0.00 0.00 0.00
April 0.499961E+11 150829.79 03-APR-06:10 0.00 0.00 0.00 0.00 0.00
May 0.229061E+11 139826.36 07-MAY-03:43 0.00 0.00 0.00 0.00 0.00
June 0.787671E+10 106183.58 07-JUN-03:18 0.00 0.00 0.00 0.00 0.00
July 0.710225E+10 101941.82 31-JUL-03:06 0.00 0.00 0.00 0.00 0.00
August 0.130682E+11 131894.04 21-AUG-02:13 0.00 0.00 0.00 0.00 0.00
September 0.319188E+11 142026.98 10-SEP-04:03 0.00 0.00 0.00 0.00 0.00
October 0.883531E+11 146808.29 22-OCT-06:05 0.00 0.00 0.00 0.00 0.00
November 0.475468E+12 548880.12 30-NOV-21:00 0.00 0.00 0.00 0.00 0.00
December 0.596197E+12 560804.88 15-DEC-08:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.246749E+13     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.710225E+10 101941.82   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.596197E+12 576535.23   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: BASEMENT VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.102614E+10 11294.79 12-JAN-10:10 0.00 0.00 0.00 0.00 0.00
February 0.809442E+09 11141.93 27-FEB-05:50 0.00 0.00 0.00 0.00 0.00
March 0.197734E+09 4292.71 01-MAR-05:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:05 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:02 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.203332E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.102614E+10 11294.79   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: RETAIL_1_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.946334E+10 7343.07 12-JAN-06:00 0.00 0.00 0.00 0.00 0.00
February 0.661673E+10 7213.73 27-FEB-05:15 0.00 0.00 0.00 0.00 0.00
March 0.452723E+10 5548.24 01-MAR-07:05 0.00 0.00 0.00 0.00 0.00
April 0.167150E+10 2754.31 03-APR-06:05 0.00 0.00 0.00 0.00 0.00
May 0.563872E+09 2576.01 02-MAY-07:08 0.00 0.00 0.00 0.00 0.00
June 0.177993E+09 1984.54 25-JUN-04:10 0.00 0.00 0.00 0.00 0.00
July 0.200402E+09 2307.82 05-JUL-03:35 0.00 0.00 0.00 0.00 0.00
August 0.421232E+09 2514.64 21-AUG-00:53 0.00 0.00 0.00 0.00 0.00
September 0.159331E+10 3043.72 21-SEP-17:47 0.00 0.00 0.00 0.00 0.00
October 0.428121E+10 3380.39 30-OCT-08:30 0.00 0.00 0.00 0.00 0.00
November 0.837215E+10 6362.96 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.101590E+11 7080.40 15-DEC-08:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.480480E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.177993E+09 1984.54   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.101590E+11 7343.07   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: RETAIL_2_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.145153E+10 2601.91 12-JAN-07:05 0.00 0.00 0.00 0.00 0.00
February 0.849596E+09 2141.63 27-FEB-10:10 0.00 0.00 0.00 0.00 0.00
March 0.311187E+09 1311.11 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00
April 12052507.55 355.39 03-APR-10:50 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 0.142210E+09 603.41 29-OCT-15:00 0.00 0.00 0.00 0.00 0.00
November 0.107269E+10 1781.26 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.156161E+10 2324.07 15-DEC-11:20 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.540087E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.156161E+10 2601.91   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: MECH_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.369367E+10 3740.55 12-JAN-11:50 0.00 0.00 0.00 0.00 0.00
February 0.284589E+10 3419.88 27-FEB-05:00 0.00 0.00 0.00 0.00 0.00
March 0.204009E+10 2514.09 01-MAR-05:00 0.00 0.00 0.00 0.00 0.00
April 0.386439E+09 1126.54 03-APR-10:50 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 36528766.49 450.56 30-SEP-10:33 0.00 0.00 0.00 0.00 0.00
October 0.101191E+10 1209.41 31-OCT-10:05 0.00 0.00 0.00 0.00 0.00
November 0.321208E+10 2585.41 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.391554E+10 3139.30 15-DEC-12:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.171421E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.391554E+10 3740.55   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: STORAGE_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.264960E+10 2181.43 12-JAN-06:00 0.00 0.00 0.00 0.00 0.00
February 0.207643E+10 2018.62 27-FEB-05:00 0.00 0.00 0.00 0.00 0.00
March 0.157883E+10 1540.72 01-MAR-05:00 0.00 0.00 0.00 0.00 0.00
April 0.359226E+09 736.34 03-APR-10:40 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 67847019.39 357.18 29-SEP-10:50 0.00 0.00 0.00 0.00 0.00
October 0.895043E+09 862.66 31-OCT-09:15 0.00 0.00 0.00 0.00 0.00
November 0.236036E+10 1682.66 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.280616E+10 1974.59 15-DEC-12:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.127935E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.280616E+10 2181.43   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: LAUNDRY_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.281558E+10 14560.70 12-JAN-06:02 0.00 0.00 0.00 0.00 0.00
February 0.152694E+10 14328.44 27-FEB-05:03 0.00 0.00 0.00 0.00 0.00
March 0.651715E+09 10793.92 01-MAR-05:00 0.00 0.00 0.00 0.00 0.00
April 31729846.41 2990.57 16-APR-16:23 0.00 0.00 0.00 0.00 0.00
May 16444029.42 6200.00 24-MAY-03:35 0.00 0.00 0.00 0.00 0.00
June 31233066.85 7314.26 03-JUN-03:00 0.00 0.00 0.00 0.00 0.00
July 20172620.67 8696.60 05-JUL-03:35 0.00 0.00 0.00 0.00 0.00
August 43799104.49 9463.45 28-AUG-03:35 0.00 0.00 0.00 0.00 0.00
September 25311464.52 8789.41 01-SEP-01:45 0.00 0.00 0.00 0.00 0.00
October 94893113.42 4719.52 04-OCT-01:40 0.00 0.00 0.00 0.00 0.00
November 0.141273E+10 11823.93 29-NOV-04:50 0.00 0.00 0.00 0.00 0.00
December 0.239778E+10 13879.03 15-DEC-05:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.906833E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 16444029.42 2990.57   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.281558E+10 14560.70   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CAFE_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.166012E+11 20345.87 12-JAN-06:04 0.00 0.00 0.00 0.00 0.00
February 0.966991E+10 19799.00 27-FEB-07:10 0.00 0.00 0.00 0.00 0.00
March 0.409903E+10 13720.35 01-MAR-07:10 0.00 0.00 0.00 0.00 0.00
April 0.703560E+09 5722.49 03-APR-08:03 0.00 0.00 0.00 0.00 0.00
May 44952100.78 6074.67 02-MAY-07:20 0.00 0.00 0.00 0.00 0.00
June 31676056.12 2782.33 25-JUN-10:45 0.00 0.00 0.00 0.00 0.00
July 10808604.87 2233.82 05-JUL-10:20 0.00 0.00 0.00 0.00 0.00
August 34490890.57 2653.95 07-AUG-10:37 0.00 0.00 0.00 0.00 0.00
September 0.686000E+09 5811.64 21-SEP-10:12 0.00 0.00 0.00 0.00 0.00
October 0.396376E+10 8229.22 30-OCT-08:40 0.00 0.00 0.00 0.00 0.00
November 0.136118E+11 17927.26 29-NOV-10:00 0.00 0.00 0.00 0.00 0.00
December 0.181146E+11 19636.14 15-DEC-08:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.675718E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 10808604.87 2233.82   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.181146E+11 20345.87   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: LOBBY_FLR_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.214729E+11 49320.45 12-JAN-10:00 0.00 0.00 0.00 0.00 0.00
February 0.106705E+11 41751.70 27-FEB-09:04 0.00 0.00 0.00 0.00 0.00
March 0.236321E+10 25339.01 01-MAR-07:05 0.00 0.00 0.00 0.00 0.00
April 69625353.68 5134.07 03-APR-08:06 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 0.136252E+10 10808.15 29-OCT-15:00 0.00 0.00 0.00 0.00 0.00
November 0.147402E+11 36417.73 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.223836E+11 47393.53 15-DEC-11:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.730625E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.223836E+11 49320.45   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CORRIDOR_FLR_3 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.247338E+11 24266.04 12-JAN-07:05 0.00 0.00 0.00 0.00 0.00
February 0.168631E+11 20528.85 27-FEB-07:10 0.00 0.00 0.00 0.00 0.00
March 0.950847E+10 15126.91 01-MAR-07:05 0.00 0.00 0.00 0.00 0.00
April 0.130973E+10 6591.02 03-APR-08:07 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.728785E+09 5169.22 24-SEP-14:07 0.00 0.00 0.00 0.00 0.00
October 0.831643E+10 9234.67 30-OCT-08:30 0.00 0.00 0.00 0.00 0.00
November 0.214139E+11 18542.73 29-NOV-10:05 0.00 0.00 0.00 0.00 0.00
December 0.264545E+11 22262.80 15-DEC-10:40 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.109329E+12     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.264545E+11 24266.04   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CORRIDOR_FLR_6 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.159447E+11 14971.79 12-JAN-06:00 0.00 0.00 0.00 0.00 0.00
February 0.113614E+11 13413.36 27-FEB-06:05 0.00 0.00 0.00 0.00 0.00
March 0.715039E+10 10181.62 01-MAR-07:05 0.00 0.00 0.00 0.00 0.00
April 0.151771E+10 4742.02 03-APR-06:05 0.00 0.00 0.00 0.00 0.00
May 2228517.48 489.01 28-MAY-03:00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.599436E+09 2656.64 30-SEP-07:00 0.00 0.00 0.00 0.00 0.00
October 0.532907E+10 5432.03 27-OCT-08:15 0.00 0.00 0.00 0.00 0.00
November 0.143237E+11 11426.25 29-NOV-10:10 0.00 0.00 0.00 0.00 0.00
December 0.171761E+11 13331.38 15-DEC-11:09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.734047E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.171761E+11 14971.79   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: BANQUET_FLR_6 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.217750E+10 18228.78 12-JAN-10:00 0.00 0.00 0.00 0.00 0.00
February 0.708820E+09 13179.40 27-FEB-09:17 0.00 0.00 0.00 0.00 0.00
March 72034873.06 5523.20 01-MAR-09:01 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.844834E+09 9577.64 29-NOV-10:00 0.00 0.00 0.00 0.00 0.00
December 0.149007E+10 13360.74 15-DEC-12:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.529326E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.217750E+10 18228.78   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: DINING_FLR_6 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.196441E+10 18252.69 12-JAN-10:00 0.00 0.00 0.00 0.00 0.00
February 0.559671E+09 12765.08 27-FEB-09:13 0.00 0.00 0.00 0.00 0.00
March 35457025.72 4588.53 01-MAR-09:01 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.643539E+09 9041.78 29-NOV-10:00 0.00 0.00 0.00 0.00 0.00
December 0.110159E+10 13009.35 15-DEC-11:57 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.430466E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.196441E+10 18252.69   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: KITCHEN_FLR_6 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.119829E+10 13144.93 12-JAN-06:02 0.00 0.00 0.00 0.00 0.00
February 0.622371E+09 12813.17 27-FEB-05:15 0.00 0.00 0.00 0.00 0.00
March 0.209988E+09 5979.40 01-MAR-04:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 57918.84 110.48 01-SEP-01:45 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.413523E+09 7309.37 29-NOV-04:00 0.00 0.00 0.00 0.00 0.00
December 0.716515E+09 10887.59 15-DEC-04:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.316075E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.119829E+10 13144.93   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: FLR_3_DOAS HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.632534E+11 69206.10 12-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.537999E+11 68231.45 27-FEB-05:00 0.00 0.00 0.00 0.00 0.00
March 0.309502E+11 64951.00 01-MAR-00:07 0.00 0.00 0.00 0.00 0.00
April 0.416912E+10 16747.70 03-APR-07:10 0.00 0.00 0.00 0.00 0.00
May 38046.06 0.85 22-MAY-18:08 0.00 0.00 0.00 0.00 0.00
June 83073.20 0.86 22-JUN-12:10 0.00 0.00 0.00 0.00 0.00
July 89197.17 0.86 31-JUL-11:00 0.00 0.00 0.00 0.00 0.00
August 49766.25 0.86 13-AUG-20:20 0.00 0.00 0.00 0.00 0.00
September 0.402138E+09 4682.02 30-SEP-07:10 0.00 0.00 0.00 0.00 0.00
October 0.116797E+11 17401.27 22-OCT-07:10 0.00 0.00 0.00 0.00 0.00
November 0.608867E+11 65449.28 29-NOV-10:00 0.00 0.00 0.00 0.00 0.00
December 0.748580E+11 67241.25 15-DEC-08:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.299999E+12     0.00 0.00 0.00 0.00 0.00
Minimum of Months 38046.06 0.85   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.748580E+11 69206.10   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_1_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.151596E+11 16386.20 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.110359E+11 16385.61 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.733502E+10 16385.64 19-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.182326E+10 16383.71 05-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.147809E+09 5901.08 27-MAY-08:62 0.00 0.00 0.00 0.00 0.00
June 4546727.12 3538.37 02-JUN-08:03 0.00 0.00 0.00 0.00 0.00
July 6725485.40 3374.00 30-JUL-08:04 0.00 0.00 0.00 0.00 0.00
August 71402192.97 8197.08 30-AUG-08:62 0.00 0.00 0.00 0.00 0.00
September 0.137814E+10 16276.69 30-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.622973E+10 16384.59 13-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.137360E+11 16384.46 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.165591E+11 16384.53 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.734872E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 4546727.12 3374.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.165591E+11 16386.20   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_2_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.156201E+11 15870.49 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.123831E+11 15869.84 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.929243E+10 15869.93 19-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.264024E+10 15868.68 08-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.197757E+09 6654.68 27-MAY-08:62 0.00 0.00 0.00 0.00 0.00
June 4430681.15 2328.42 26-JUN-08:04 0.00 0.00 0.00 0.00 0.00
July 6468285.76 3472.74 30-JUL-08:04 0.00 0.00 0.00 0.00 0.00
August 0.112010E+09 10580.72 30-AUG-08:62 0.00 0.00 0.00 0.00 0.00
September 0.188224E+10 15793.34 30-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.730670E+10 15868.82 13-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.144813E+11 15868.74 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.167246E+11 15868.70 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.806515E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 4430681.15 2328.42   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.167246E+11 15870.49   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.722650E+11 68107.02 12-JAN-02:50 0.00 0.00 0.00 0.00 0.00
February 0.390710E+11 58343.86 27-FEB-06:00 0.00 0.00 0.00 0.00 0.00
March 0.112419E+11 49451.64 01-MAR-05:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:05 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 73071260.97 5676.77 28-SEP-05:00 0.00 0.00 0.00 0.00 0.00
October 0.115351E+11 24934.41 22-OCT-05:00 0.00 0.00 0.00 0.00 0.00
November 0.602278E+11 54392.24 29-NOV-05:00 0.00 0.00 0.00 0.00 0.00
December 0.852477E+11 63071.49 15-DEC-05:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.279662E+12     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.852477E+11 68107.02   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.754024E+11 85937.00 07-JAN-16:01 0.00 0.00 0.00 0.00 0.00
February 0.605103E+11 85930.21 03-FEB-16:01 0.00 0.00 0.00 0.00 0.00
March 0.440944E+11 85923.36 12-MAR-15:01 0.00 0.00 0.00 0.00 0.00
April 0.124674E+11 85766.90 02-APR-15:01 0.00 0.00 0.00 0.00 0.00
May 0.177611E+09 35086.34 21-MAY-15:05 0.00 0.00 0.00 0.00 0.00
June 26865997.53 20527.14 27-JUN-08:06 0.00 0.00 0.00 0.00 0.00
July 33181831.96 20119.42 25-JUL-08:06 0.00 0.00 0.00 0.00 0.00
August 0.231217E+09 37436.45 07-AUG-15:04 0.00 0.00 0.00 0.00 0.00
September 0.400884E+10 83887.43 29-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.272842E+11 85925.08 29-OCT-15:01 0.00 0.00 0.00 0.00 0.00
November 0.700005E+11 85928.51 10-NOV-09:01 0.00 0.00 0.00 0.00 0.00
December 0.820373E+11 85930.07 25-DEC-16:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.376274E+12     0.00 0.00 0.00 0.00 0.00
Minimum of Months 26865997.53 20119.42   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.820373E+11 85937.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_5_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.150303E+11 16094.05 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.104920E+11 16093.42 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.623560E+10 16091.84 09-MAR-09:01 0.00 0.00 0.00 0.00 0.00
April 0.179325E+10 16090.61 04-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 98319206.60 4617.17 26-MAY-18:02 0.00 0.00 0.00 0.00 0.00
June 2795407.36 2125.26 25-JUN-08:05 0.00 0.00 0.00 0.00 0.00
July 3381843.73 2567.10 17-JUL-15:04 0.00 0.00 0.00 0.00 0.00
August 50904131.40 3394.95 29-AUG-08:03 0.00 0.00 0.00 0.00 0.00
September 0.113092E+10 15587.50 27-SEP-15:01 0.00 0.00 0.00 0.00 0.00
October 0.561958E+10 16092.10 25-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.137277E+11 16092.38 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.165494E+11 16092.30 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.707341E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 2795407.36 2125.26   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.165494E+11 16094.05   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_6_FLR_3 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.154796E+11 15596.01 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.117848E+11 15595.33 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.793444E+10 15594.70 09-MAR-09:01 0.00 0.00 0.00 0.00 0.00
April 0.262850E+10 15593.24 05-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.146145E+09 3483.66 28-MAY-08:03 0.00 0.00 0.00 0.00 0.00
June 4311106.12 2151.62 24-JUN-08:05 0.00 0.00 0.00 0.00 0.00
July 4231325.64 2360.51 01-JUL-08:05 0.00 0.00 0.00 0.00 0.00
August 78758743.99 3118.90 20-AUG-18:03 0.00 0.00 0.00 0.00 0.00
September 0.152435E+10 15181.71 29-SEP-15:01 0.00 0.00 0.00 0.00 0.00
October 0.659188E+10 15594.05 25-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.144676E+11 15594.20 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.167044E+11 15594.16 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.773490E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 4231325.64 2151.62   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.167044E+11 15596.01   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_1_FLR_6 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.486321E+10 4787.97 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.361892E+10 4787.73 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.250568E+10 4787.71 19-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.717554E+09 4787.32 08-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.108935E+09 3232.48 27-MAY-08:62 0.00 0.00 0.00 0.00 0.00
June 6408513.72 742.57 02-JUN-08:03 0.00 0.00 0.00 0.00 0.00
July 8260771.06 1009.98 04-JUL-08:03 0.00 0.00 0.00 0.00 0.00
August 52371957.28 4204.85 30-AUG-08:62 0.00 0.00 0.00 0.00 0.00
September 0.591875E+09 4764.63 30-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.216394E+10 4787.44 13-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.445262E+10 4787.37 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.526834E+10 4787.39 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.243581E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 6408513.72 742.57   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.526834E+10 4787.97   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_2_FLR_6 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.499113E+10 4602.67 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.399693E+10 4602.47 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.309687E+10 4602.41 19-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.100105E+10 4601.99 08-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.142485E+09 3480.48 27-MAY-08:62 0.00 0.00 0.00 0.00 0.00
June 6546466.46 727.09 02-JUN-08:03 0.00 0.00 0.00 0.00 0.00
July 8290275.78 914.42 04-JUL-08:03 0.00 0.00 0.00 0.00 0.00
August 77988964.53 4492.54 31-AUG-08:62 0.00 0.00 0.00 0.00 0.00
September 0.781236E+09 4580.36 30-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.248811E+10 4602.12 13-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.465926E+10 4602.09 02-NOV-08:61 0.00 0.00 0.00 0.00 0.00
December 0.531071E+10 4602.05 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.265606E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 6546466.46 727.09   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.531071E+10 4602.67   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.203963E+11 24288.54 07-JAN-09:01 0.00 0.00 0.00 0.00 0.00
February 0.126883E+11 24287.49 02-FEB-09:01 0.00 0.00 0.00 0.00 0.00
March 0.731466E+10 24287.13 09-MAR-09:01 0.00 0.00 0.00 0.00 0.00
April 0.171717E+10 24285.28 05-APR-08:61 0.00 0.00 0.00 0.00 0.00
May 0.177656E+09 7306.14 26-MAY-18:02 0.00 0.00 0.00 0.00 0.00
June 8507785.34 4920.07 02-JUN-08:03 0.00 0.00 0.00 0.00 0.00
July 12984102.01 5307.71 17-JUL-08:03 0.00 0.00 0.00 0.00 0.00
August 72225433.04 7592.38 30-AUG-08:62 0.00 0.00 0.00 0.00 0.00
September 0.114729E+10 23802.30 28-SEP-08:61 0.00 0.00 0.00 0.00 0.00
October 0.650442E+10 24285.75 25-OCT-08:61 0.00 0.00 0.00 0.00 0.00
November 0.178074E+11 24286.02 18-NOV-09:01 0.00 0.00 0.00 0.00 0.00
December 0.232402E+11 24286.14 25-DEC-09:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.910872E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 8507785.34 4920.07   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.232402E+11 24288.54   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: VAV WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 10389.95 10389.95 34.63 19-JAN-06:20 34.63 0.00
February 0.00 0.00 12630076.55 12630076.55 3883.87 07-FEB-21:10 3883.87 0.00
March 0.00 0.00 55323215.14 55323215.14 15137.64 22-MAR-18:49 15137.64 0.00
April 0.00 0.00 0.612247E+09 0.612247E+09 20916.25 27-APR-22:36 20916.25 0.00
May 0.00 0.00 0.330998E+11 0.330998E+11 150268.02 31-MAY-18:03 150268.02 0.00
June 0.00 0.00 0.128881E+12 0.127899E+12 239341.11 29-JUN-20:00 222714.32 0.19
July 0.00 0.00 0.163163E+12 0.161095E+12 254705.18 29-JUL-18:03 217386.37 0.56
August 0.00 0.00 0.955801E+11 0.954680E+11 221678.89 11-AUG-20:10 221678.89 0.36
September 0.00 0.00 0.426427E+10 0.426427E+10 56246.15 02-SEP-17:50 56246.15 0.00
October 0.00 0.00 0.215145E+09 0.215145E+09 32355.45 07-OCT-20:40 32355.45 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 0.00
December 0.00 0.00 767558.00 767558.00 652.83 24-DEC-06:40 652.83 0.00
                 
Annual Sum or Average 0.00 0.00 0.425884E+12 0.422722E+12       0.09
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.163163E+12 0.161095E+12 254705.18   222714.32 0.56



Table of Contents

Report: CoilReportMonthly

For: FLR_3_DOAS COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 01-MAR-00:03 0.00 0.00
April 0.00 0.00 12777529.52 12777529.52 2561.18 22-APR-14:00 2561.18 0.00
May 0.00 0.00 0.491070E+10 0.491070E+10 24999.69 31-MAY-16:00 24999.69 0.00
June 0.00 0.00 0.211800E+11 0.209782E+11 35079.14 30-JUN-11:00 27090.40 0.17
July 0.00 0.00 0.271142E+11 0.266102E+11 39281.29 03-JUL-15:00 16760.87 0.51
August 0.00 0.00 0.159136E+11 0.158183E+11 29129.45 11-AUG-18:02 29129.45 0.32
September 0.00 0.00 0.477581E+09 0.477581E+09 8431.64 07-SEP-16:00 8431.64 0.00
October 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.696088E+11 0.688077E+11       0.08
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.271142E+11 0.266102E+11 39281.29   29129.45 0.51



Table of Contents

Report: CoilReportMonthly

For: ROOM_1_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 835052.91 835052.91 1653.52 22-JAN-09:04 1653.52 0.00
February 0.00 0.00 5620793.55 5620793.55 2543.83 11-FEB-19:04 2543.83 0.00
March 0.00 0.00 0.149968E+09 0.149968E+09 14508.22 22-MAR-15:02 14508.22 0.00
April 0.00 0.00 0.266479E+10 0.266479E+10 15228.80 30-APR-15:02 15228.80 0.00
May 0.00 0.00 0.497982E+10 0.496830E+10 16081.95 31-MAY-18:02 16081.95 0.01
June 0.00 0.00 0.783000E+10 0.623750E+10 16453.32 13-JUN-15:02 16453.32 0.56
July 0.00 0.00 0.772311E+10 0.489012E+10 16297.12 26-JUL-15:02 14378.03 0.88
August 0.00 0.00 0.548435E+10 0.357947E+10 16270.36 10-AUG-18:02 16270.36 0.72
September 0.00 0.00 0.115939E+10 0.103894E+10 15389.21 02-SEP-18:02 15389.21 0.08
October 0.00 0.00 46503300.04 46503300.04 15231.87 03-OCT-15:01 15231.87 0.00
November 0.00 0.00 861891.61 861891.61 1071.89 01-NOV-15:04 1071.89 0.00
December 0.00 0.00 676886.25 676886.25 2126.16 24-DEC-09:04 2126.16 0.00
                 
Annual Sum or Average 0.00 0.00 0.300459E+11 0.235836E+11       0.19
Minimum of Months 0.00 0.00 676886.25 676886.25 1071.89   1071.89 0.00
Maximum of Months 0.00 0.00 0.783000E+10 0.623750E+10 16453.32   16453.32 0.88



Table of Contents

Report: CoilReportMonthly

For: ROOM_2_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 1160395.53 1160395.53 1914.45 22-JAN-09:04 1914.45 0.00
February 0.00 0.00 4495597.56 4495597.56 2921.53 09-FEB-16:04 2921.53 0.00
March 0.00 0.00 15372209.97 15372209.97 4538.03 20-MAR-15:03 4538.03 0.00
April 0.00 0.00 0.131473E+10 0.131473E+10 13592.89 30-APR-18:01 13592.89 0.00
May 0.00 0.00 0.345305E+10 0.344540E+10 14355.38 31-MAY-18:02 14355.38 0.01
June 0.00 0.00 0.678843E+10 0.545222E+10 14686.60 13-JUN-15:02 14686.60 0.54
July 0.00 0.00 0.649482E+10 0.413124E+10 14531.03 26-JUL-15:02 12761.74 0.83
August 0.00 0.00 0.380422E+10 0.239281E+10 14560.53 03-AUG-15:02 13171.87 0.63
September 0.00 0.00 0.477110E+09 0.422394E+09 13736.57 02-SEP-18:02 13736.57 0.05
October 0.00 0.00 16998779.84 16998779.84 5598.45 04-OCT-18:03 5598.45 0.00
November 0.00 0.00 852305.11 852305.11 1151.03 04-NOV-08:04 1151.03 0.00
December 0.00 0.00 891469.05 891469.05 2409.32 24-DEC-09:04 2409.32 0.00
                 
Annual Sum or Average 0.00 0.00 0.223721E+11 0.171986E+11       0.17
Minimum of Months 0.00 0.00 852305.11 852305.11 1151.03   1151.03 0.00
Maximum of Months 0.00 0.00 0.678843E+10 0.545222E+10 14686.60   14686.60 0.83



Table of Contents

Report: CoilReportMonthly

For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:03 0.00 0.00
March 0.00 0.00 0.121275E+10 0.121275E+10 21663.62 29-MAR-14:30 21663.62 0.00
April 0.00 0.00 0.220677E+11 0.220677E+11 64515.83 22-APR-13:20 64515.83 0.00
May 0.00 0.00 0.304516E+11 0.304516E+11 60207.34 12-MAY-13:20 60207.34 0.00
June 0.00 0.00 0.349707E+11 0.305177E+11 58334.07 30-JUN-12:30 51916.21 0.25
July 0.00 0.00 0.378253E+11 0.245944E+11 64743.91 23-JUL-13:30 51705.85 0.69
August 0.00 0.00 0.339423E+11 0.256484E+11 68415.92 25-AUG-13:30 61392.54 0.47
September 0.00 0.00 0.124307E+11 0.124307E+11 58718.87 09-SEP-13:10 58718.87 0.00
October 0.00 0.00 0.869594E+09 0.869594E+09 29725.74 03-OCT-12:55 29725.74 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.173771E+12 0.147793E+12       0.12
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.378253E+11 0.305177E+11 68415.92   64515.83 0.69



Table of Contents

Report: CoilReportMonthly

For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 22257334.70 22257334.70 22705.78 16-JAN-09:04 22705.78 0.00
February 0.00 0.00 42923003.20 42923003.20 41394.64 10-FEB-19:04 41394.64 0.00
March 0.00 0.00 88869808.34 88869808.34 39076.95 10-MAR-19:04 39076.95 0.00
April 0.00 0.00 0.361338E+10 0.361338E+10 63309.47 30-APR-18:01 63309.47 0.00
May 0.00 0.00 0.237146E+11 0.236544E+11 69730.58 31-MAY-18:02 69730.58 0.01
June 0.00 0.00 0.439852E+11 0.379408E+11 73622.64 22-JUN-18:02 73622.64 0.44
July 0.00 0.00 0.460262E+11 0.334648E+11 73979.01 13-JUL-18:02 73979.01 0.69
August 0.00 0.00 0.275036E+11 0.186816E+11 70559.92 11-AUG-15:02 70559.92 0.58
September 0.00 0.00 0.506412E+10 0.396714E+10 62300.05 10-SEP-18:02 62300.05 0.15
October 0.00 0.00 0.362716E+09 0.362716E+09 41482.36 07-OCT-08:62 41482.36 0.00
November 0.00 0.00 23172360.99 23172360.99 32011.63 05-NOV-08:04 32011.63 0.00
December 0.00 0.00 21082777.04 21082777.04 34597.52 24-DEC-19:04 34597.52 0.00
                 
Annual Sum or Average 0.00 0.00 0.150468E+12 0.121883E+12       0.16
Minimum of Months 0.00 0.00 21082777.04 21082777.04 22705.78   22705.78 0.00
Maximum of Months 0.00 0.00 0.460262E+11 0.379408E+11 73979.01   73979.01 0.69



Table of Contents

Report: CoilReportMonthly

For: ROOM_5_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 1109822.07 1109822.07 1846.97 22-JAN-09:04 1846.97 0.00
February 0.00 0.00 7397102.85 7397102.85 2754.74 10-FEB-19:04 2754.74 0.00
March 0.00 0.00 0.208639E+09 0.208639E+09 14037.60 22-MAR-15:02 14037.60 0.00
April 0.00 0.00 0.243515E+10 0.243515E+10 14319.78 28-APR-08:62 14319.78 0.00
May 0.00 0.00 0.717769E+10 0.716828E+10 15115.40 31-MAY-18:02 15115.40 0.01
June 0.00 0.00 0.908307E+10 0.748815E+10 15365.67 22-JUN-18:02 15365.67 0.61
July 0.00 0.00 0.971902E+10 0.682431E+10 15265.50 26-JUL-15:02 13544.89 0.93
August 0.00 0.00 0.682301E+10 0.478675E+10 15292.78 10-AUG-18:02 15292.78 0.76
September 0.00 0.00 0.163548E+10 0.145340E+10 14393.33 07-SEP-15:02 14393.33 0.13
October 0.00 0.00 0.109892E+09 0.109892E+09 14288.95 03-OCT-15:01 14288.95 0.00
November 0.00 0.00 1013856.27 1013856.27 1030.26 04-NOV-08:04 1030.26 0.00
December 0.00 0.00 835768.88 835768.88 2288.88 24-DEC-09:04 2288.88 0.00
                 
Annual Sum or Average 0.00 0.00 0.372023E+11 0.304849E+11       0.20
Minimum of Months 0.00 0.00 835768.88 835768.88 1030.26   1030.26 0.00
Maximum of Months 0.00 0.00 0.971902E+10 0.748815E+10 15365.67   15365.67 0.93



Table of Contents

Report: CoilReportMonthly

For: ROOM_6_FLR_3 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 1335792.75 1335792.75 1666.96 22-JAN-09:04 1666.96 0.00
February 0.00 0.00 5294172.98 5294172.98 3017.11 09-FEB-19:04 3017.11 0.00
March 0.00 0.00 57371211.43 57371211.43 5089.07 10-MAR-09:03 5089.07 0.00
April 0.00 0.00 0.961823E+09 0.961823E+09 12865.87 28-APR-08:62 12865.87 0.00
May 0.00 0.00 0.544065E+10 0.543412E+10 13581.01 31-MAY-18:02 13581.01 0.01
June 0.00 0.00 0.794952E+10 0.658651E+10 13805.57 22-JUN-18:02 13805.57 0.60
July 0.00 0.00 0.839012E+10 0.582789E+10 13890.54 13-JUL-18:02 13890.54 0.91
August 0.00 0.00 0.496463E+10 0.332733E+10 13757.84 03-AUG-15:02 12471.41 0.72
September 0.00 0.00 0.716234E+09 0.622020E+09 12872.35 09-SEP-08:62 12872.35 0.08
October 0.00 0.00 31693289.68 31693289.68 11321.76 04-OCT-08:61 11321.76 0.00
November 0.00 0.00 901989.21 901989.21 1333.23 04-NOV-08:04 1333.23 0.00
December 0.00 0.00 1002959.42 1002959.42 2563.43 24-DEC-09:04 2563.43 0.00
                 
Annual Sum or Average 0.00 0.00 0.285206E+11 0.228573E+11       0.19
Minimum of Months 0.00 0.00 901989.21 901989.21 1333.23   1333.23 0.00
Maximum of Months 0.00 0.00 0.839012E+10 0.658651E+10 13890.54   13890.54 0.91



Table of Contents

Report: CoilReportMonthly

For: ROOM_1_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 0.00
February 0.00 0.00 69791.87 69791.87 243.61 09-FEB-16:04 243.61 0.00
March 0.00 0.00 26109425.55 26109425.55 3724.27 22-MAR-15:02 3724.27 0.00
April 0.00 0.00 0.648124E+09 0.648124E+09 3966.85 30-APR-18:01 3966.85 0.00
May 0.00 0.00 0.112432E+10 0.112236E+10 4189.13 31-MAY-18:02 4189.13 0.01
June 0.00 0.00 0.186134E+10 0.148687E+10 4286.03 13-JUN-15:02 4286.03 0.55
July 0.00 0.00 0.183417E+10 0.117535E+10 4284.48 13-JUL-18:02 4284.48 0.85
August 0.00 0.00 0.124512E+10 0.840460E+09 4239.81 13-AUG-08:62 3217.29 0.64
September 0.00 0.00 0.246804E+09 0.227911E+09 4008.75 02-SEP-18:02 4008.75 0.05
October 0.00 0.00 6613907.03 6607442.95 3954.05 03-OCT-15:01 3954.05 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:02 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.699267E+10 0.553386E+10       0.18
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.186134E+10 0.148687E+10 4286.03   4286.03 0.85



Table of Contents

Report: CoilReportMonthly

For: ROOM_2_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 0.00
February 0.00 0.00 35519.84 35519.84 199.95 09-FEB-16:04 199.95 0.00
March 0.00 0.00 1742105.67 1742105.67 1466.01 20-MAR-15:03 1466.01 0.00
April 0.00 0.00 0.302715E+09 0.302715E+09 3500.75 30-APR-18:01 3500.75 0.00
May 0.00 0.00 0.723627E+09 0.722540E+09 3697.03 31-MAY-18:02 3697.03 0.00
June 0.00 0.00 0.157032E+10 0.125208E+10 3782.42 13-JUN-15:02 3782.42 0.52
July 0.00 0.00 0.149362E+10 0.950234E+09 3781.13 13-JUL-18:02 3781.13 0.79
August 0.00 0.00 0.803736E+09 0.528545E+09 3754.92 03-AUG-15:02 3389.57 0.52
September 0.00 0.00 85310602.06 78724407.14 3537.68 02-SEP-18:02 3537.68 0.02
October 0.00 0.00 2191372.62 2173421.66 1873.61 02-OCT-15:03 1873.61 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:05 0.00 0.00
December 0.00 0.00 574.94 574.94 6.71 24-DEC-09:04 6.71 0.00
                 
Annual Sum or Average 0.00 0.00 0.498330E+10 0.383879E+10       0.16
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.157032E+10 0.125208E+10 3782.42   3782.42 0.79



Table of Contents

Report: CoilReportMonthly

For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 1656852.58 1656852.58 2218.37 22-JAN-09:04 2218.37 0.00
February 0.00 0.00 0.141852E+09 0.141852E+09 23613.76 15-FEB-16:01 23613.76 0.00
March 0.00 0.00 0.203473E+10 0.203473E+10 23688.01 22-MAR-15:02 23688.01 0.00
April 0.00 0.00 0.648031E+10 0.648031E+10 23697.07 30-APR-15:02 23697.07 0.00
May 0.00 0.00 0.871220E+10 0.866997E+10 25017.16 31-MAY-18:02 25017.16 0.02
June 0.00 0.00 0.109604E+11 0.846765E+10 25429.54 22-JUN-18:02 25429.54 0.61
July 0.00 0.00 0.120262E+11 0.765976E+10 25584.97 13-JUL-18:02 25584.97 0.88
August 0.00 0.00 0.102720E+11 0.712828E+10 25308.67 10-AUG-18:02 25308.67 0.75
September 0.00 0.00 0.400769E+10 0.361010E+10 23940.32 02-SEP-18:02 23940.32 0.17
October 0.00 0.00 0.925303E+09 0.925042E+09 23701.22 03-OCT-15:01 23701.22 0.00
November 0.00 0.00 5963798.85 5963798.85 12189.39 08-NOV-16:01 12189.39 0.00
December 0.00 0.00 993946.49 993946.49 2726.89 24-DEC-09:04 2726.89 0.00
                 
Annual Sum or Average 0.00 0.00 0.555693E+11 0.451263E+11       0.20
Minimum of Months 0.00 0.00 993946.49 993946.49 2218.37   2218.37 0.00
Maximum of Months 0.00 0.00 0.120262E+11 0.866997E+10 25584.97   25584.97 0.88



Table of Contents

Report: PlantLoopDemandReportMonthly

For: HEATSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 336414.75 1068591.40 12-JAN-09:03
February 0.00 0.00 01-FEB-00:03 292247.11 981931.47 27-FEB-09:03
March 0.00 0.00 01-MAR-00:03 151012.73 862041.20 01-MAR-09:03
April 0.00 0.00 01-APR-00:10 32425.16 341909.32 03-APR-08:61
May 0.00 0.00 01-MAY-00:03 9128.72 127849.86 29-MAY-23:18
June 0.00 0.00 01-JUN-00:05 3127.43 115294.75 07-JUN-03:18
July 0.00 0.00 01-JUL-00:10 2744.25 111151.19 31-JUL-03:48
August 0.00 0.00 01-AUG-00:05 5296.77 132312.67 20-AUG-08:02
September 0.00 0.00 01-SEP-00:05 18524.95 246384.11 29-SEP-08:61
October 0.00 0.00 01-OCT-00:10 74282.32 356639.74 22-OCT-08:61
November 0.00 0.00 01-NOV-00:05 318447.62 938503.95 29-NOV-09:03
December 0.00 0.00 01-DEC-00:02 387759.44 1000360.59 15-DEC-09:03
             
Annual Sum or Average 0.00     135135.57    
Minimum of Months 0.00 0.00   2744.25 111151.19  
Maximum of Months 0.00 0.00   387759.44 1068591.40  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: COOLSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 16.70 23676.77 16-JAN-09:04 0.00 0.00 01-JAN-00:05
February 233.10 63254.55 09-FEB-09:04 0.00 0.00 01-FEB-00:03
March 2236.35 64645.37 29-MAR-15:06 0.00 0.00 01-MAR-00:03
April 18577.47 181601.99 22-APR-15:02 0.00 0.00 01-APR-00:10
May 50823.10 352472.20 31-MAY-15:03 0.00 0.00 01-MAY-00:03
June 111506.37 421246.93 20-JUN-18:03 0.00 0.00 01-JUN-00:05
July 125611.13 478655.46 29-JUL-18:03 0.00 0.00 01-JUL-00:10
August 81994.14 415182.66 11-AUG-18:03 0.00 0.00 01-AUG-00:05
September 14603.90 183293.68 02-SEP-18:02 0.00 0.00 01-SEP-00:05
October 1756.99 86905.59 03-OCT-15:03 0.00 0.00 01-OCT-00:10
November 26.24 25689.76 05-NOV-08:04 0.00 0.00 01-NOV-00:05
December 15.47 35307.43 24-DEC-19:04 0.00 0.00 01-DEC-00:02
             
Annual Sum or Average 34202.79     0.00    
Minimum of Months 15.47 23676.77   0.00 0.00  
Maximum of Months 125611.13 478655.46   0.00 0.00  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 33736.79 68795.01 05-JAN-07:20
February 0.00 0.00 01-FEB-00:03 33743.39 68793.65 02-FEB-07:20
March 0.00 0.00 01-MAR-00:03 33766.04 68795.34 31-MAR-06:20
April 0.00 0.00 01-APR-00:10 33727.67 77674.55 13-APR-17:01
May 0.00 0.00 01-MAY-00:03 33486.92 80940.08 15-MAY-06:49
June 0.00 0.00 01-JUN-00:05 32303.38 75387.20 01-JUN-06:24
July 0.00 0.00 01-JUL-00:10 31123.84 71882.82 13-JUL-06:12
August 0.00 0.00 01-AUG-00:05 30414.98 72393.52 28-AUG-06:09
September 0.00 0.00 01-SEP-00:05 30309.55 70700.28 03-SEP-06:31
October 0.00 0.00 01-OCT-00:10 30887.34 67307.70 02-OCT-17:51
November 0.00 0.00 01-NOV-00:05 31955.27 66287.95 30-NOV-07:10
December 0.00 0.00 01-DEC-00:02 33223.39 68754.13 29-DEC-08:00
             
Annual Sum or Average 0.00     32382.22    
Minimum of Months 0.00 0.00   30309.55 66287.95  
Maximum of Months 0.00 0.00   33766.04 80940.08  



Table of Contents

Report: FanReportMonthly

For: FLR_3_DOAS FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.587890E+10 0.90 2194.93 01-JAN-00:05 0.90
February 0.530997E+10 0.90 2194.93 01-FEB-00:03 0.90
March 0.587890E+10 0.90 2194.93 01-MAR-00:03 0.90
April 0.568926E+10 0.89 2194.93 01-APR-00:10 0.90
May 0.587890E+10 0.89 2194.93 01-MAY-00:03 0.89
June 0.568926E+10 0.89 2194.93 01-JUN-00:05 0.89
July 0.587890E+10 0.89 2194.93 01-JUL-00:10 0.88
August 0.587890E+10 0.89 2194.93 01-AUG-00:05 0.89
September 0.568926E+10 0.89 2194.93 01-SEP-00:05 0.89
October 0.587890E+10 0.89 2194.93 01-OCT-00:10 0.89
November 0.568926E+10 0.90 2194.93 01-NOV-00:05 0.89
December 0.587890E+10 0.90 2194.93 01-DEC-00:02 0.90
           
Annual Sum or Average 0.692193E+11 0.89      
Minimum of Months 0.530997E+10 0.89 2194.93   0.88
Maximum of Months 0.587890E+10 0.90 2194.93   0.90



Table of Contents

Report: FanReportMonthly

For: VAV WITH REHEAT FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.288770E+11 0.73 15666.43 19-JAN-21:10 0.89
February 0.265569E+11 0.73 16528.36 08-FEB-21:20 0.91
March 0.308208E+11 0.75 26052.94 22-MAR-14:43 1.20
April 0.327875E+11 0.79 37103.71 13-APR-20:10 1.49
May 0.374190E+11 0.83 37103.71 01-MAY-21:45 1.49
June 0.370627E+11 0.83 37103.71 01-JUN-03:33 1.48
July 0.379815E+11 0.83 36496.93 31-JUL-02:65 1.46
August 0.379228E+11 0.83 43509.81 29-AUG-21:55 1.64
September 0.358316E+11 0.82 42827.80 18-SEP-22:40 1.62
October 0.331411E+11 0.78 39290.94 04-OCT-02:23 1.55
November 0.284974E+11 0.73 17630.77 01-NOV-20:10 0.95
December 0.286086E+11 0.72 15375.05 26-DEC-21:20 0.88
           
Annual Sum or Average 0.395507E+12 0.78      
Minimum of Months 0.265569E+11 0.72 15375.05   0.88
Maximum of Months 0.379815E+11 0.83 43509.81   1.64



Table of Contents

Report: FanReportMonthly

For: LAUNDRY_FLR_1 EXHAUST FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.205205E+09 0.27 76.61 01-JAN-00:05 0.27
February 0.185347E+09 0.27 76.61 01-FEB-00:03 0.27
March 0.205205E+09 0.27 76.61 01-MAR-00:03 0.27
April 0.198586E+09 0.27 76.61 01-APR-00:10 0.27
May 0.205205E+09 0.27 76.61 01-MAY-00:03 0.27
June 0.198586E+09 0.27 76.61 01-JUN-00:05 0.27
July 0.205205E+09 0.27 76.61 01-JUL-00:10 0.27
August 0.205205E+09 0.27 76.61 01-AUG-00:05 0.27
September 0.198586E+09 0.27 76.61 01-SEP-00:05 0.27
October 0.205205E+09 0.27 76.61 01-OCT-00:10 0.27
November 0.198586E+09 0.27 76.61 01-NOV-00:05 0.27
December 0.205205E+09 0.27 76.61 01-DEC-00:02 0.27
           
Annual Sum or Average 0.241613E+10 0.27      
Minimum of Months 0.185347E+09 0.27 76.61   0.27
Maximum of Months 0.205205E+09 0.27 76.61   0.27



Table of Contents

Report: FanReportMonthly

For: LOBBY_FLR_1 EXHAUST FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.00 0.00 0.00 01-JAN-00:05 0.00
February 0.00 0.00 0.00 01-FEB-00:03 0.00
March 0.00 0.00 0.00 01-MAR-00:03 0.00
April 0.00 0.00 0.00 01-APR-00:10 0.00
May 0.00 0.00 0.00 01-MAY-00:03 0.00
June 0.00 0.00 0.00 01-JUN-00:05 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00
August 0.00 0.00 0.00 01-AUG-00:05 0.00
September 0.00 0.00 0.00 01-SEP-00:05 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00
November 0.00 0.00 0.00 01-NOV-00:05 0.00
December 0.00 0.00 0.00 01-DEC-00:02 0.00
           
Annual Sum or Average 0.00 0.00      
Minimum of Months 0.00 0.00 0.00   0.00
Maximum of Months 0.00 0.00 0.00   0.00



Table of Contents

Report: FanReportMonthly

For: BANQUET_FLR_6 EXHAUST FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.00 -0.0 0.00 01-JAN-00:05 0.00
February 0.00 0.00 0.00 01-FEB-00:03 0.00
March 0.00 0.00 0.00 01-MAR-00:03 0.00
April 0.00 -0.0 0.00 01-APR-00:10 0.00
May 0.00 -0.0 0.00 01-MAY-00:03 0.00
June 0.00 0.00 0.00 01-JUN-00:05 0.00
July 0.00 -0.0 0.00 01-JUL-00:10 0.00
August 0.00 0.00 0.00 01-AUG-00:05 0.00
September 0.00 -0.0 0.00 01-SEP-00:05 0.00
October 0.00 -0.0 0.00 01-OCT-00:10 0.00
November 0.00 -0.0 0.00 01-NOV-00:05 0.00
December 0.00 0.00 0.00 01-DEC-00:02 0.00
           
Annual Sum or Average 0.00 -0.0      
Minimum of Months 0.00 -0.0 0.00   0.00
Maximum of Months 0.00 0.00 0.00   0.00



Table of Contents

Report: FanReportMonthly

For: DINING_FLR_6 EXHAUST FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.00 -0.0 0.00 01-JAN-00:05 0.00
February 0.00 0.00 0.00 01-FEB-00:03 0.00
March 0.00 -0.0 0.00 01-MAR-00:03 0.00
April 0.00 -0.0 0.00 01-APR-00:10 0.00
May 0.00 -0.0 0.00 01-MAY-00:03 0.00
June 0.00 -0.0 0.00 01-JUN-00:05 0.00
July 0.00 -0.0 0.00 01-JUL-00:10 0.00
August 0.00 0.00 0.00 01-AUG-00:05 0.00
September 0.00 0.00 0.00 01-SEP-00:05 0.00
October 0.00 -0.0 0.00 01-OCT-00:10 0.00
November 0.00 0.00 0.00 01-NOV-00:05 0.00
December 0.00 0.00 0.00 01-DEC-00:02 0.00
           
Annual Sum or Average 0.00 0.00      
Minimum of Months 0.00 -0.0 0.00   0.00
Maximum of Months 0.00 0.00 0.00   0.00



Table of Contents

Report: FanReportMonthly

For: KITCHEN_FLR_6 EXHAUST FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.116283E+10 0.19 612.92 01-JAN-07:05 0.27
February 0.105030E+10 0.19 612.92 01-FEB-07:05 0.27
March 0.116283E+10 0.19 612.92 01-MAR-07:05 0.27
April 0.112532E+10 0.19 612.92 01-APR-06:10 0.27
May 0.116283E+10 0.19 612.92 01-MAY-06:01 0.27
June 0.112532E+10 0.19 612.92 01-JUN-06:03 0.27
July 0.116283E+10 0.19 612.92 01-JUL-06:05 0.27
August 0.116283E+10 0.19 612.92 01-AUG-06:10 0.27
September 0.112532E+10 0.19 612.92 01-SEP-06:02 0.27
October 0.116283E+10 0.19 612.92 01-OCT-06:10 0.27
November 0.112532E+10 0.19 612.92 01-NOV-06:05 0.27
December 0.116283E+10 0.19 612.92 01-DEC-07:05 0.27
           
Annual Sum or Average 0.136914E+11 0.19      
Minimum of Months 0.105030E+10 0.19 612.92   0.27
Maximum of Months 0.116283E+10 0.19 612.92   0.27



Table of Contents

Report: FanReportMonthly

For: ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.560489E+09 0.58 919.39 01-JAN-09:01 0.59
February 0.414698E+09 0.56 919.39 01-FEB-09:01 0.59
March 0.317220E+09 0.48 919.39 01-MAR-09:01 0.59
April 0.272767E+09 0.47 919.39 01-APR-08:61 0.59
May 0.335544E+09 0.51 919.39 01-MAY-15:02 0.59
June 0.475637E+09 0.53 919.39 01-JUN-08:62 0.58
July 0.451369E+09 0.52 919.39 01-JUL-08:62 0.58
August 0.347959E+09 0.50 919.39 01-AUG-08:62 0.58
September 0.170161E+09 0.44 919.39 01-SEP-15:02 0.58
October 0.286097E+09 0.49 919.39 02-OCT-08:61 0.58
November 0.500863E+09 0.58 919.39 01-NOV-08:61 0.59
December 0.578939E+09 0.58 919.39 01-DEC-09:01 0.59
           
Annual Sum or Average 0.471175E+10 0.52      
Minimum of Months 0.170161E+09 0.44 919.39   0.58
Maximum of Months 0.578939E+09 0.58 919.39   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.536777E+09 0.58 820.31 01-JAN-09:01 0.59
February 0.426067E+09 0.57 820.31 01-FEB-09:01 0.59
March 0.352220E+09 0.54 820.31 01-MAR-09:01 0.59
April 0.213179E+09 0.45 820.31 01-APR-08:61 0.59
May 0.244502E+09 0.45 820.31 01-MAY-15:02 0.59
June 0.414279E+09 0.50 820.31 01-JUN-08:62 0.58
July 0.382475E+09 0.49 820.31 01-JUL-08:62 0.58
August 0.248464E+09 0.45 820.31 01-AUG-08:62 0.58
September 0.141644E+09 0.43 820.31 01-SEP-15:02 0.58
October 0.300566E+09 0.52 820.31 01-OCT-08:62 0.58
November 0.487242E+09 0.58 820.31 01-NOV-08:61 0.59
December 0.548165E+09 0.58 820.31 01-DEC-09:01 0.59
           
Annual Sum or Average 0.429558E+10 0.51      
Minimum of Months 0.141644E+09 0.43 820.31   0.58
Maximum of Months 0.548165E+09 0.58 820.31   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.318532E+10 0.58 3720.99 12-JAN-06:00 0.59
February 0.189394E+10 0.49 2006.62 27-FEB-06:00 0.59
March 0.718154E+09 0.24 1796.53 01-MAR-05:00 0.59
April 0.120277E+10 0.22 3611.66 22-APR-13:20 0.59
May 0.170735E+10 0.37 3374.38 09-MAY-13:20 0.59
June 0.190954E+10 0.48 3015.13 16-JUN-13:40 0.59
July 0.203681E+10 0.48 3804.76 21-JUL-13:30 0.58
August 0.193998E+10 0.42 4094.85 26-AUG-12:30 0.58
September 0.728739E+09 0.19 3363.12 09-SEP-13:10 0.58
October 0.778968E+09 0.27 1492.46 03-OCT-13:00 0.59
November 0.276611E+10 0.57 1914.33 29-NOV-05:00 0.59
December 0.356525E+10 0.59 2114.98 15-DEC-05:00 0.59
           
Annual Sum or Average 0.224329E+11 0.41      
Minimum of Months 0.718154E+09 0.19 1492.46   0.58
Maximum of Months 0.356525E+10 0.59 4094.85   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.265837E+10 0.53 4065.93 01-JAN-09:01 0.59
February 0.214109E+10 0.51 4065.93 01-FEB-09:01 0.59
March 0.160048E+10 0.46 4065.93 01-MAR-09:01 0.59
April 0.823615E+09 0.42 4065.93 01-APR-08:61 0.59
May 0.144548E+10 0.41 4065.93 01-MAY-08:62 0.59
June 0.268066E+10 0.41 4065.93 01-JUN-08:62 0.58
July 0.261255E+10 0.41 4065.93 01-JUL-08:62 0.58
August 0.157193E+10 0.41 4065.93 01-AUG-08:62 0.58
September 0.625474E+09 0.41 4065.93 01-SEP-15:02 0.58
October 0.113200E+10 0.44 4065.93 02-OCT-15:01 0.58
November 0.243194E+10 0.54 4065.93 01-NOV-08:61 0.59
December 0.282597E+10 0.54 4065.93 01-DEC-09:01 0.59
           
Annual Sum or Average 0.225496E+11 0.46      
Minimum of Months 0.625474E+09 0.41 4065.93   0.58
Maximum of Months 0.282597E+10 0.54 4065.93   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.538173E+09 0.58 863.96 01-JAN-09:01 0.59
February 0.382895E+09 0.55 863.96 01-FEB-09:01 0.59
March 0.270373E+09 0.45 863.96 01-MAR-09:01 0.59
April 0.248180E+09 0.49 863.96 01-APR-08:61 0.59
May 0.451357E+09 0.54 863.96 01-MAY-08:62 0.58
June 0.559146E+09 0.55 863.96 01-JUN-08:62 0.58
July 0.557856E+09 0.55 863.96 01-JUL-08:62 0.58
August 0.413737E+09 0.53 863.96 01-AUG-08:62 0.58
September 0.181941E+09 0.46 863.96 01-SEP-08:62 0.58
October 0.256268E+09 0.48 863.96 02-OCT-15:01 0.58
November 0.481649E+09 0.58 863.96 01-NOV-08:61 0.59
December 0.557925E+09 0.58 863.96 01-DEC-09:01 0.59
           
Annual Sum or Average 0.489950E+10 0.53      
Minimum of Months 0.181941E+09 0.45 863.96   0.58
Maximum of Months 0.559146E+09 0.58 863.96   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.515830E+09 0.58 775.88 01-JAN-09:01 0.59
February 0.398311E+09 0.57 775.88 01-FEB-09:01 0.59
March 0.297891E+09 0.49 775.88 01-MAR-09:01 0.59
April 0.185701E+09 0.44 775.88 01-APR-08:61 0.59
May 0.356989E+09 0.52 775.88 01-MAY-08:62 0.58
June 0.502234E+09 0.54 775.88 01-JUN-08:62 0.58
July 0.491830E+09 0.54 775.88 01-JUL-08:62 0.58
August 0.310578E+09 0.50 775.88 01-AUG-08:62 0.58
September 0.137400E+09 0.42 775.88 01-SEP-08:62 0.58
October 0.266920E+09 0.50 775.88 02-OCT-15:01 0.58
November 0.473192E+09 0.58 775.88 01-NOV-08:61 0.59
December 0.534293E+09 0.58 775.88 01-DEC-09:01 0.59
           
Annual Sum or Average 0.447117E+10 0.52      
Minimum of Months 0.137400E+09 0.42 775.88   0.58
Maximum of Months 0.534293E+09 0.58 775.88   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.161463E+09 0.58 239.54 01-JAN-09:01 0.59
February 0.121592E+09 0.57 239.54 01-FEB-09:01 0.59
March 94896154.12 0.51 239.54 01-MAR-09:01 0.59
April 75923304.25 0.47 239.54 01-APR-08:61 0.59
May 80056627.02 0.50 239.54 01-MAY-15:02 0.59
June 0.114587E+09 0.52 239.54 01-JUN-08:62 0.58
July 0.109399E+09 0.52 239.54 01-JUL-08:62 0.58
August 82081457.97 0.50 239.54 01-AUG-08:62 0.58
September 49249826.71 0.44 239.54 01-SEP-15:02 0.58
October 86865086.02 0.51 239.54 02-OCT-08:61 0.58
November 0.145271E+09 0.58 239.54 01-NOV-08:61 0.59
December 0.167352E+09 0.58 239.54 01-DEC-09:01 0.59
           
Annual Sum or Average 0.128874E+10 0.52      
Minimum of Months 49249826.71 0.44 239.54   0.58
Maximum of Months 0.167352E+09 0.58 239.54   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.153862E+09 0.58 211.29 01-JAN-09:01 0.59
February 0.123748E+09 0.58 211.29 01-FEB-09:01 0.59
March 0.104453E+09 0.56 211.29 01-MAR-09:01 0.59
April 61439102.56 0.46 211.29 01-APR-08:61 0.59
May 56626517.29 0.44 211.29 01-MAY-15:02 0.59
June 98194007.94 0.50 211.29 01-JUN-08:62 0.58
July 90541733.11 0.49 211.29 01-JUL-08:62 0.58
August 56297481.07 0.45 211.29 01-AUG-08:62 0.58
September 43589335.64 0.44 211.29 01-SEP-15:02 0.58
October 89485896.40 0.54 211.29 01-OCT-08:62 0.58
November 0.145556E+09 0.58 211.29 01-NOV-08:61 0.59
December 0.161595E+09 0.58 211.29 01-DEC-09:01 0.59
           
Annual Sum or Average 0.118539E+10 0.52      
Minimum of Months 43589335.64 0.44 211.29   0.58
Maximum of Months 0.161595E+09 0.58 211.29   0.59



Table of Contents

Report: FanReportMonthly

For: ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.779076E+09 0.56 1424.36 01-JAN-09:01 0.59
February 0.523757E+09 0.51 1424.36 01-FEB-09:01 0.59
March 0.462682E+09 0.49 1424.36 01-MAR-09:01 0.59
April 0.500794E+09 0.52 1424.36 01-APR-08:61 0.59
May 0.547857E+09 0.52 1424.36 01-MAY-15:02 0.59
June 0.643559E+09 0.52 1424.36 01-JUN-08:62 0.58
July 0.675159E+09 0.52 1424.36 01-JUL-08:62 0.58
August 0.620784E+09 0.52 1424.36 01-AUG-08:62 0.58
September 0.340351E+09 0.47 1424.36 01-SEP-15:02 0.58
October 0.380658E+09 0.47 1424.36 01-OCT-15:02 0.58
November 0.689704E+09 0.55 1424.36 01-NOV-08:61 0.59
December 0.853714E+09 0.58 1424.36 01-DEC-09:01 0.59
           
Annual Sum or Average 0.701809E+10 0.52      
Minimum of Months 0.340351E+09 0.47 1424.36   0.58
Maximum of Months 0.853714E+09 0.58 1424.36   0.59



Table of Contents

Report: PumpReportMonthly

For: HEATSYS1 PUMP

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.350864E+10 0.315777E+10 2425.11 12-JAN-09:13 2182.60 2182.60 49.14 7.72
February 0.278978E+10 0.251080E+10 2239.56 27-FEB-05:00 2015.60 2015.60 50.02 7.17
March 0.199141E+10 0.179226E+10 2098.20 01-MAR-07:10 1888.38 1888.38 52.06 6.57
April 0.637023E+09 0.573321E+09 1279.50 03-APR-08:61 1151.55 1151.55 38.29 1.86
May 0.146331E+09 0.131698E+09 607.60 07-MAY-03:43 546.84 546.84 38.63 0.70
June 41937912.75 37744121.47 529.31 02-JUN-00:33 476.38 476.38 36.52 0.60
July 40127652.63 36114887.37 505.96 31-JUL-03:06 455.36 455.36 34.38 0.57
August 89935889.92 80942300.93 655.54 21-AUG-02:10 589.98 589.98 46.19 0.77
September 0.422888E+09 0.380600E+09 1028.87 24-SEP-15:01 925.98 925.98 37.18 1.35
October 0.140878E+10 0.126790E+10 1414.70 27-OCT-08:61 1273.23 1273.23 43.61 2.20
November 0.330697E+10 0.297628E+10 2175.20 29-NOV-10:05 1957.68 1957.68 51.01 6.92
December 0.381262E+10 0.343136E+10 2294.13 15-DEC-10:40 2064.72 2064.72 50.67 7.35
                 
Annual Sum or Average 0.181964E+11 0.163768E+11            
Minimum of Months 40127652.63 36114887.37 505.96   455.36 455.36 34.38 0.57
Maximum of Months 0.381262E+10 0.343136E+10 2425.11   2182.60 2182.60 52.06 7.72



Table of Contents

Report: PumpReportMonthly

For: COOLSYS1 PUMP SECONDARY

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 2199702.56 1979732.30 1323.61 16-JAN-09:04 1191.25 1191.25 8.40 2.26
February 14472890.16 13025601.15 1940.15 09-FEB-09:04 1746.13 1746.13 8.40 3.58
March 0.230187E+09 0.207168E+09 2281.73 29-MAR-15:06 2053.56 2053.56 8.40 4.43
April 0.189980E+10 0.170982E+10 3415.32 23-APR-15:02 3073.79 3073.79 8.40 8.56
May 0.445865E+10 0.401278E+10 3890.37 31-MAY-15:03 3501.34 3501.34 7.55 12.06
June 0.639583E+10 0.575625E+10 4271.83 21-JUN-18:03 3844.65 3844.65 6.92 17.75
July 0.683755E+10 0.615379E+10 4338.25 10-JUL-18:03 3904.43 3904.43 7.20 18.68
August 0.542532E+10 0.488279E+10 4275.24 25-AUG-18:03 3847.72 3847.72 7.26 17.80
September 0.156157E+10 0.140541E+10 3491.59 02-SEP-15:02 3142.43 3142.43 8.24 8.98
October 0.160663E+09 0.144596E+09 2640.35 03-OCT-15:03 2376.31 2376.31 8.40 5.46
November 2493727.39 2244354.65 1422.92 05-NOV-08:04 1280.63 1280.63 8.40 2.45
December 1632564.20 1469307.78 1651.79 24-DEC-19:04 1486.61 1486.61 8.40 2.93
                 
Annual Sum or Average 0.269904E+11 0.242913E+11            
Minimum of Months 1632564.20 1469307.78 1323.61   1191.25 1191.25 6.92 2.26
Maximum of Months 0.683755E+10 0.615379E+10 4338.25   3904.43 3904.43 8.40 18.68



Table of Contents

Report: PumpReportMonthly

For: COOLSYS1 PUMP

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 15986711.74 14388040.56 3621.59 01-JAN-09:04 3259.43 3259.43 8.42 25.38
February 0.367694E+09 0.330925E+09 3621.59 01-FEB-19:06 3259.43 3259.43 8.54 25.38
March 0.214543E+10 0.193089E+10 3621.59 01-MAR-09:04 3259.43 3259.43 8.42 25.38
April 0.593167E+10 0.533850E+10 3621.59 01-APR-08:03 3259.43 3259.43 8.40 25.38
May 0.930190E+10 0.837171E+10 3621.59 01-MAY-00:03 3259.43 3259.43 8.43 25.38
June 0.930432E+10 0.837389E+10 3621.59 01-JUN-00:05 3259.43 3259.43 8.69 25.38
July 0.965578E+10 0.869020E+10 3621.59 01-JUL-00:10 3259.43 3259.43 8.81 25.38
August 0.945510E+10 0.850959E+10 3621.59 01-AUG-00:05 3259.43 3259.43 9.01 25.38
September 0.654828E+10 0.589345E+10 3621.59 01-SEP-00:05 3259.43 3259.43 8.43 25.38
October 0.219588E+10 0.197629E+10 3621.59 01-OCT-01:07 3259.43 3259.43 8.40 25.38
November 36629747.28 32966772.55 3621.59 01-NOV-08:04 3259.43 3259.43 8.43 25.38
December 16762765.71 15086489.13 3621.59 01-DEC-19:06 3259.43 3259.43 8.43 25.38
                 
Annual Sum or Average 0.549754E+11 0.494779E+11            
Minimum of Months 15986711.74 14388040.56 3621.59   3259.43 3259.43 8.40 25.38
Maximum of Months 0.965578E+10 0.869020E+10 3621.59   3259.43 3259.43 9.01 25.38



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.128314E+09 38494137.67 47.91 01-JAN-00:05 14.37 14.37 45.60 0.37
February 0.115896E+09 34768898.54 47.91 01-FEB-00:03 14.37 14.37 46.37 0.37
March 0.128314E+09 38494137.67 47.91 01-MAR-00:03 14.37 14.37 46.18 0.37
April 0.124175E+09 37252391.29 47.91 01-APR-00:10 14.37 14.37 49.53 0.37
May 0.128314E+09 38494137.67 47.91 01-MAY-00:03 14.37 14.37 49.07 0.37
June 0.124175E+09 37252391.29 47.91 01-JUN-00:05 14.37 14.37 49.51 0.37
July 0.128314E+09 38494137.67 47.91 01-JUL-00:10 14.37 14.37 50.26 0.37
August 0.128314E+09 38494137.67 47.91 01-AUG-00:05 14.37 14.37 50.75 0.37
September 0.124175E+09 37252391.29 47.91 01-SEP-00:05 14.37 14.37 50.85 0.37
October 0.128314E+09 38494137.67 47.91 01-OCT-00:10 14.37 14.37 49.80 0.37
November 0.124175E+09 37252391.29 47.91 01-NOV-00:05 14.37 14.37 50.37 0.37
December 0.128314E+09 38494137.67 47.91 01-DEC-00:02 14.37 14.37 46.71 0.37
                 
Annual Sum or Average 0.151079E+10 0.453237E+09            
Minimum of Months 0.115896E+09 34768898.54 47.91   14.37 14.37 45.60 0.37
Maximum of Months 0.128314E+09 38494137.67 47.91   14.37 14.37 50.85 0.37



Table of Contents

Report: CondLoopDemandReportMonthly

For: HEATSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 50.88 82.20 336414.75 1068591.40 12-JAN-09:03
February 0.00 0.00 01-FEB-00:03 49.63 82.20 292247.11 981931.47 27-FEB-09:03
March 0.00 0.00 01-MAR-00:03 51.57 82.20 151012.73 862041.20 01-MAR-09:03
April 0.00 0.00 01-APR-00:10 54.08 82.20 32425.16 341909.32 03-APR-08:61
May 0.00 0.00 01-MAY-00:03 46.73 79.95 9128.72 127849.86 29-MAY-23:18
June 0.00 0.00 01-JUN-00:05 31.42 31.42 3127.43 115294.75 07-JUN-03:18
July 0.00 0.00 01-JUL-00:10 31.87 31.87 2744.25 111151.19 31-JUL-03:48
August 0.00 0.00 01-AUG-00:05 34.44 34.44 5296.77 132312.67 20-AUG-08:02
September 0.00 0.00 01-SEP-00:05 44.53 79.72 18524.95 246384.11 29-SEP-08:61
October 0.00 0.00 01-OCT-00:10 66.91 80.84 74282.32 356639.74 22-OCT-08:61
November 0.00 0.00 01-NOV-00:05 56.03 82.20 318447.62 938503.95 29-NOV-09:03
December 0.00 0.00 01-DEC-00:02 52.33 82.20 387759.44 1000360.59 15-DEC-09:03
                 
Annual Sum or Average 0.00         135135.57    
Minimum of Months 0.00 0.00   31.42 31.42 2744.25 111151.19  
Maximum of Months 0.00 0.00   66.91 82.20 387759.44 1068591.40  



Table of Contents

Report: CondLoopDemandReportMonthly

For: COOLSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 16.70 23676.77 16-JAN-09:04 8.59 8.37 0.00 0.00 01-JAN-00:05
February 233.10 63254.55 09-FEB-09:04 8.96 8.37 0.00 0.00 01-FEB-00:03
March 2236.35 64645.37 29-MAR-15:06 8.98 8.37 0.00 0.00 01-MAR-00:03
April 18577.47 181601.99 22-APR-15:02 10.08 8.37 0.00 0.00 01-APR-00:10
May 50823.10 352472.20 31-MAY-15:03 10.83 7.51 0.00 0.00 01-MAY-00:03
June 111506.37 421246.93 20-JUN-18:03 10.66 6.70 0.00 0.00 01-JUN-00:05
July 125611.13 478655.46 29-JUL-18:03 11.20 6.70 0.00 0.00 01-JUL-00:10
August 81994.14 415182.66 11-AUG-18:03 10.78 6.88 0.00 0.00 01-AUG-00:05
September 14603.90 183293.68 02-SEP-18:02 9.96 8.23 0.00 0.00 01-SEP-00:05
October 1756.99 86905.59 03-OCT-15:03 9.19 8.37 0.00 0.00 01-OCT-00:10
November 26.24 25689.76 05-NOV-08:04 8.61 8.37 0.00 0.00 01-NOV-00:05
December 15.47 35307.43 24-DEC-19:04 8.70 8.37 0.00 0.00 01-DEC-00:02
                 
Annual Sum or Average 34202.79         0.00    
Minimum of Months 15.47 23676.77   8.59 6.70 0.00 0.00  
Maximum of Months 125611.13 478655.46   11.20 8.37 0.00 0.00  



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 45.60 59.63 33736.79 68795.01 05-JAN-07:20
February 0.00 0.00 01-FEB-00:03 46.37 58.95 33743.39 68793.65 02-FEB-07:20
March 0.00 0.00 01-MAR-00:03 46.18 59.20 33766.04 68795.34 31-MAR-06:20
April 0.00 0.00 01-APR-00:10 49.53 58.43 33727.67 77674.55 13-APR-17:01
May 0.00 0.00 01-MAY-00:03 49.07 58.74 33486.92 80940.08 15-MAY-06:49
June 0.00 0.00 01-JUN-00:05 49.51 58.36 32303.38 75387.20 01-JUN-06:24
July 0.00 0.00 01-JUL-00:10 50.26 58.65 31123.84 71882.82 13-JUL-06:12
August 0.00 0.00 01-AUG-00:05 50.75 59.72 30414.98 72393.52 28-AUG-06:09
September 0.00 0.00 01-SEP-00:05 50.85 59.17 30309.55 70700.28 03-SEP-06:31
October 0.00 0.00 01-OCT-00:10 49.80 59.02 30887.34 67307.70 02-OCT-17:51
November 0.00 0.00 01-NOV-00:05 50.37 59.15 31955.27 66287.95 30-NOV-07:10
December 0.00 0.00 01-DEC-00:02 46.71 59.18 33223.39 68754.13 29-DEC-08:00
                 
Annual Sum or Average 0.00         32382.22    
Minimum of Months 0.00 0.00   45.60 58.36 30309.55 66287.95  
Maximum of Months 0.00 0.00   50.85 59.72 33766.04 80940.08  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: VAV WITH REHEAT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.606072E+12 0.00 10389.95 0.288770E+11 0.00 0.00
February 0.493478E+12 0.00 12630076.55 0.265569E+11 0.00 0.00
March 0.278172E+12 0.00 55323215.14 0.308208E+11 0.00 0.00
April 0.560576E+11 0.00 0.612247E+09 0.327875E+11 0.00 0.00
May 0.235336E+11 0.00 0.330998E+11 0.374190E+11 0.00 0.00
June 0.811761E+10 0.00 0.128881E+12 0.370627E+11 0.00 0.00
July 0.733364E+10 0.00 0.163163E+12 0.379815E+11 0.00 0.00
August 0.135677E+11 0.00 0.955801E+11 0.379228E+11 0.00 0.00
September 0.356561E+11 0.00 0.426427E+10 0.358316E+11 0.00 0.00
October 0.113750E+12 0.00 0.215145E+09 0.331411E+11 0.00 0.00
November 0.557890E+12 0.00 0.00 0.284974E+11 0.00 0.00
December 0.704474E+12 0.00 767558.00 0.286086E+11 0.00 0.00
             
Annual Sum or Average 0.289810E+13 0.00 0.425884E+12 0.395507E+12 0.00 0.00
Minimum of Months 0.733364E+10 0.00 0.00 0.265569E+11 0.00 0.00
Maximum of Months 0.704474E+12 0.00 0.163163E+12 0.379815E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: FLR_3_DOAS

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.632534E+11 0.00 0.00 0.587890E+10 0.00 0.00
February 0.537999E+11 0.00 0.00 0.530997E+10 0.00 0.00
March 0.309502E+11 0.00 0.00 0.587890E+10 0.00 0.00
April 0.416912E+10 0.00 12777529.52 0.568926E+10 0.00 0.00
May 38046.06 0.00 0.491070E+10 0.587890E+10 0.00 0.00
June 83073.20 0.00 0.211800E+11 0.568926E+10 0.00 0.00
July 89197.17 0.00 0.271142E+11 0.587890E+10 0.00 0.00
August 49766.25 0.00 0.159136E+11 0.587890E+10 0.00 0.00
September 0.402138E+09 0.00 0.477581E+09 0.568926E+10 0.00 0.00
October 0.116797E+11 0.00 0.00 0.587890E+10 0.00 0.00
November 0.608867E+11 0.00 0.00 0.568926E+10 0.00 0.00
December 0.748580E+11 0.00 0.00 0.587890E+10 0.00 0.00
             
Annual Sum or Average 0.299999E+12 0.00 0.696088E+11 0.692193E+11 0.00 0.00
Minimum of Months 38046.06 0.00 0.00 0.530997E+10 0.00 0.00
Maximum of Months 0.748580E+11 0.00 0.271142E+11 0.587890E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: VAV WITH REHEAT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.288770E+11 10389.95 0.606072E+12 0.745956E+12 0.00 0.00 0.00 0.00
February 0.265569E+11 12630076.55 0.493478E+12 0.628824E+12 0.00 0.00 0.00 0.00
March 0.308208E+11 55323215.14 0.278172E+12 0.758650E+12 0.00 0.00 0.00 0.00
April 0.327875E+11 0.612275E+09 0.560576E+11 0.507940E+12 0.00 0.00 0.00 0.00
May 0.374190E+11 0.330999E+11 0.235336E+11 0.152449E+12 0.00 0.00 0.00 0.00
June 0.370627E+11 0.128881E+12 0.811761E+10 0.306057E+11 0.106571E+09 0.00 0.00 0.00
July 0.379815E+11 0.163163E+12 0.733364E+10 0.290515E+11 0.562007E+09 0.00 0.00 0.00
August 0.379228E+11 0.955801E+11 0.135677E+11 0.665338E+11 0.00 0.00 0.00 0.00
September 0.358316E+11 0.426470E+10 0.356561E+11 0.279008E+12 0.00 0.00 0.00 0.00
October 0.331411E+11 0.215145E+09 0.113750E+12 0.645151E+12 0.00 0.00 0.00 0.00
November 0.284974E+11 0.00 0.557890E+12 0.743869E+12 0.00 0.00 0.00 0.00
December 0.286086E+11 767558.00 0.704474E+12 0.709996E+12 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.395507E+12 0.425885E+12 0.289810E+13 0.529803E+13 0.668578E+09 0.00 0.00 0.00
Minimum of Months 0.265569E+11 0.00 0.733364E+10 0.290515E+11 0.00 0.00 0.00 0.00
Maximum of Months 0.379815E+11 0.163163E+12 0.704474E+12 0.758650E+12 0.562007E+09 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: FLR_3_DOAS

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.587890E+10 0.00 0.632534E+11 0.136501E+12 0.00 0.00 0.00 0.00
February 0.530997E+10 0.00 0.537999E+11 0.114642E+12 0.00 0.00 0.00 0.00
March 0.587890E+10 0.00 0.309502E+11 0.138381E+12 0.00 0.00 0.00 0.00
April 0.568926E+10 12777529.52 0.416912E+10 0.958747E+11 0.00 0.00 0.00 0.00
May 0.587890E+10 0.491070E+10 38046.06 0.360066E+11 0.00 0.00 0.00 0.00
June 0.568926E+10 0.211800E+11 83073.20 0.910583E+10 0.387207E+09 0.00 0.00 0.00
July 0.587890E+10 0.271142E+11 89197.17 0.779220E+10 0.997594E+09 0.00 0.00 0.00
August 0.587890E+10 0.159136E+11 49766.25 0.176018E+11 0.132370E+09 0.00 0.00 0.00
September 0.568926E+10 0.477581E+09 0.402138E+09 0.594307E+11 0.00 0.00 0.00 0.00
October 0.587890E+10 0.00 0.116797E+11 0.117683E+12 0.00 0.00 0.00 0.00
November 0.568926E+10 0.00 0.608867E+11 0.135414E+12 0.00 0.00 0.00 0.00
December 0.587890E+10 0.00 0.748580E+11 0.130434E+12 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.692193E+11 0.696088E+11 0.299999E+12 0.998866E+12 0.151717E+10 0.00 0.00 0.00
Minimum of Months 0.530997E+10 0.00 38046.06 0.779220E+10 0.00 0.00 0.00 0.00
Maximum of Months 0.587890E+10 0.271142E+11 0.748580E+11 0.138381E+12 0.997594E+09 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: VAV WITH REHEAT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.288770E+11 0.606072E+12 10389.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.265569E+11 0.493478E+12 12630076.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.308208E+11 0.278172E+12 55323215.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.327875E+11 0.560576E+11 0.612247E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.374190E+11 0.235336E+11 0.330998E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.370627E+11 0.811761E+10 0.128881E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.379815E+11 0.733364E+10 0.163163E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.379228E+11 0.135677E+11 0.955801E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.358316E+11 0.356561E+11 0.426427E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.331411E+11 0.113750E+12 0.215145E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.284974E+11 0.557890E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.286086E+11 0.704474E+12 767558.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.395507E+12 0.289810E+13 0.425884E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.265569E+11 0.733364E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.379815E+11 0.704474E+12 0.163163E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: FLR_3_DOAS

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.587890E+10 0.632534E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.530997E+10 0.537999E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.587890E+10 0.309502E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.568926E+10 0.416912E+10 12777529.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.587890E+10 38046.06 0.491070E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.568926E+10 83073.20 0.211800E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.587890E+10 89197.17 0.271142E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.587890E+10 49766.25 0.159136E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.568926E+10 0.402138E+09 0.477581E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.587890E+10 0.116797E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.568926E+10 0.608867E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.587890E+10 0.748580E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.692193E+11 0.299999E+12 0.696088E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.530997E+10 38046.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.587890E+10 0.748580E+11 0.271142E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: BASEMENT

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.883072E+11 0.00 0.00 183036.16 0.00 0.00 0.190059E+10 0.00 0.87
February 0.777955E+11 0.00 0.00 0.00 0.00 0.217822E+09 0.00 0.00 0.85
March 0.631827E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.84
April 0.449100E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.82
May 0.430099E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.83
June 0.340670E+11 0.00 0.00 0.00 3868175.83 0.00 0.00 0.00 0.87
July 0.246703E+11 1487238.86 0.00 7286238.15 14188400.41 0.00 0.827745E+10 0.00 0.87
August 0.657763E+10 0.00 0.00 55660936.06 0.00 0.00 0.352178E+11 0.00 0.93
September 0.270888E+10 0.00 0.00 0.114034E+09 0.00 0.00 0.490063E+11 0.00 0.95
October 0.229256E+10 0.00 0.00 84484436.76 0.00 0.00 0.530400E+11 0.00 0.94
November 0.342583E+11 0.00 0.00 39696066.07 0.00 0.00 0.556086E+11 0.00 0.92
December 0.837040E+11 0.00 0.00 5757892.80 0.00 0.00 0.154596E+11 0.00 0.88
                   
Annual Sum or Average 0.505484E+12 1487238.86 0.00 0.307102E+09 18056576.24 0.217822E+09 0.218510E+12 0.00 0.88
Minimum of Months 0.229256E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.82
Maximum of Months 0.883072E+11 1487238.86 0.00 0.114034E+09 14188400.41 0.217822E+09 0.556086E+11 0.00 0.95



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: RETAIL_1_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.217221E+09 0.00 0.00 0.00 0.00 0.204659E+11 0.00 0.00 3.60
February 0.175586E+10 0.00 0.00 0.00 0.00 0.160768E+11 0.00 0.00 3.53
March 0.490600E+10 0.00 0.00 448645.62 0.00 0.877604E+10 0.758629E+09 0.00 3.47
April 0.757572E+10 0.00 0.00 3663546.25 0.00 0.113781E+10 0.178566E+10 0.00 3.48
May 0.844379E+10 0.00 0.00 2116751.20 0.00 2690492.31 0.149430E+10 0.00 3.49
June 0.666067E+10 1000793.52 0.00 2330460.08 0.00 0.00 0.115980E+10 0.00 3.63
July 0.674100E+10 3725445.12 0.00 2629247.37 154688.94 2299521.90 0.796510E+09 0.00 3.66
August 0.771254E+10 0.00 0.00 2765294.40 0.00 1522049.99 0.121347E+10 0.00 3.65
September 0.890202E+10 0.00 0.00 1001717.16 0.00 0.248890E+09 0.775553E+09 0.00 3.35
October 0.530110E+10 0.00 0.00 311021.01 0.00 0.553817E+10 0.199070E+09 0.00 3.40
November 0.424418E+09 0.00 0.00 0.00 0.00 0.191134E+11 0.00 0.00 3.55
December 0.00 0.00 0.00 0.00 0.00 0.226099E+11 0.00 0.00 3.60
                   
Annual Sum or Average 0.586403E+11 4726238.64 0.00 15266683.09 154688.94 0.939734E+11 0.818300E+10 0.00 3.54
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3.35
Maximum of Months 0.890202E+10 3725445.12 0.00 3663546.25 154688.94 0.226099E+11 0.178566E+10 0.00 3.66



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: RETAIL_2_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.739576E+10 0.00 0.00 0.00 0.00 0.173426E+10 0.00 0.00 1.38
February 0.750201E+10 0.00 0.00 0.00 0.00 0.386705E+09 0.00 0.00 1.35
March 0.638944E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.33
April 0.398852E+10 0.00 0.00 686901.78 0.00 0.00 0.571945E+09 0.00 1.30
May 0.314430E+10 0.00 0.00 1209063.85 0.00 0.00 0.124839E+10 0.00 1.33
June 0.172889E+10 0.00 0.00 2064681.08 391174.60 0.00 0.179260E+10 0.00 1.42
July 0.156465E+10 1024936.51 0.00 2107372.90 576208.11 0.00 0.183148E+10 0.00 1.42
August 0.226894E+10 0.00 0.00 1772233.58 0.00 0.00 0.168798E+10 0.00 1.39
September 0.384537E+10 0.00 0.00 334516.89 0.00 0.00 0.524913E+09 0.00 1.28
October 0.485347E+10 0.00 0.00 6457.70 0.00 0.00 29208223.16 0.00 1.30
November 0.793106E+10 0.00 0.00 0.00 0.00 0.716203E+09 0.00 0.00 1.36
December 0.748937E+10 0.00 0.00 0.00 0.00 0.251040E+10 0.00 0.00 1.38
                   
Annual Sum or Average 0.581018E+11 1024936.51 0.00 8181227.77 967382.72 0.534757E+10 0.768651E+10 0.00 1.35
Minimum of Months 0.156465E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.28
Maximum of Months 0.793106E+10 1024936.51 0.00 2107372.90 576208.11 0.251040E+10 0.183148E+10 0.00 1.42



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: MECH_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.464286E+09 0.00 0.00 0.00 0.00 0.786037E+10 0.00 0.00 0.59
February 0.746209E+09 0.00 0.00 0.00 0.00 0.645265E+10 0.00 0.00 0.58
March 0.207715E+10 0.00 0.00 0.00 0.00 0.375354E+10 0.00 0.00 0.57
April 0.375547E+10 0.00 0.00 0.00 0.00 0.388962E+09 0.00 0.00 0.56
May 0.396830E+10 0.00 0.00 23.96 0.00 0.00 787987.77 0.00 0.57
June 0.279916E+10 0.00 0.00 452030.04 356966.90 0.00 0.354028E+09 0.00 0.60
July 0.256324E+10 171712.06 0.00 655787.21 1274883.07 0.00 0.490953E+09 0.00 0.60
August 0.335382E+10 0.00 0.00 230111.35 0.00 0.00 0.202323E+09 0.00 0.59
September 0.398752E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.55
October 0.320649E+10 0.00 0.00 0.00 0.00 0.124921E+10 0.00 0.00 0.56
November 0.568802E+09 0.00 0.00 0.00 0.00 0.732227E+10 0.00 0.00 0.59
December 0.252911E+09 0.00 0.00 0.00 0.00 0.887240E+10 0.00 0.00 0.59
                   
Annual Sum or Average 0.277434E+11 171712.06 0.00 1337952.56 1631849.96 0.358994E+11 0.104809E+10 0.00 0.58
Minimum of Months 0.252911E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.55
Maximum of Months 0.398752E+10 171712.06 0.00 655787.21 1274883.07 0.887240E+10 0.490953E+09 0.00 0.60



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: STORAGE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.00 0.00 0.00 0.00 0.00 0.403565E+10 0.00 0.00 0.50
February 35994150.33 0.00 0.00 0.00 0.00 0.344945E+10 0.00 0.00 0.49
March 0.300568E+09 0.00 0.00 0.00 0.00 0.252246E+10 0.00 0.00 0.48
April 0.164167E+10 0.00 0.00 0.00 0.00 0.364928E+09 0.00 0.00 0.47
May 0.192170E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.47
June 0.151010E+10 0.00 0.00 8168.72 172831.33 0.00 12020590.26 0.00 0.50
July 0.143917E+10 0.00 0.00 22537.86 700392.55 0.00 30422434.49 0.00 0.50
August 0.172038E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.49
September 0.193062E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.46
October 0.105981E+10 0.00 0.00 0.00 0.00 0.109749E+10 0.00 0.00 0.47
November 0.00 0.00 0.00 0.00 0.00 0.382059E+10 0.00 0.00 0.49
December 0.00 0.00 0.00 0.00 0.00 0.441817E+10 0.00 0.00 0.50
                   
Annual Sum or Average 0.115600E+11 0.00 0.00 30706.58 873223.87 0.197087E+11 42443024.75 0.00 0.48
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.46
Maximum of Months 0.193062E+10 0.00 0.00 22537.86 700392.55 0.441817E+10 30422434.49 0.00 0.50



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: LAUNDRY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.652773E+10 0.00 0.00 82916627.22 0.00 0.264463E+09 0.129298E+12 0.00 20.80
February 0.398927E+10 0.00 0.00 77924255.79 0.00 23674296.64 0.115261E+12 0.00 20.55
March 0.100948E+10 0.00 0.00 96520108.01 0.00 0.00 0.974178E+11 0.00 20.57
April 0.564617E+09 0.00 0.00 0.151461E+09 0.00 0.00 0.722900E+11 0.00 20.39
May 0.666408E+09 0.00 0.00 0.162121E+09 0.00 0.00 0.705231E+11 0.00 21.25
June 0.749240E+09 5207325.07 0.00 0.112412E+09 0.00 0.00 0.536522E+11 0.00 22.14
July 0.509659E+09 23924679.13 0.00 0.113518E+09 0.00 0.00 0.518849E+11 0.00 22.04
August 0.537267E+09 0.00 0.00 0.127421E+09 0.00 0.00 0.617572E+11 0.00 21.87
September 0.102239E+10 0.00 0.00 0.171618E+09 0.00 0.00 0.704865E+11 0.00 20.51
October 0.816854E+09 0.00 0.00 0.123973E+09 0.00 0.00 0.765805E+11 0.00 20.33
November 0.285248E+10 0.00 0.00 82256156.38 0.00 0.00 0.127260E+12 0.00 20.56
December 0.433465E+10 0.00 0.00 81707381.50 0.00 0.00 0.147005E+12 0.00 20.77
                   
Annual Sum or Average 0.235801E+11 29132004.20 0.00 0.138385E+10 0.00 0.288137E+09 0.107342E+13 0.00 20.99
Minimum of Months 0.509659E+09 0.00 0.00 77924255.79 0.00 0.00 0.518849E+11 0.00 20.33
Maximum of Months 0.652773E+10 23924679.13 0.00 0.171618E+09 0.00 0.264463E+09 0.147005E+12 0.00 22.14



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CAFE_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.486658E+11 0.00 0.00 0.00 0.00 0.280295E+11 0.00 0.00 4.75
February 0.579133E+11 0.00 0.00 25517.58 0.00 0.802484E+10 0.254597E+09 0.00 4.66
March 0.470798E+11 0.00 0.00 3941622.22 0.00 0.924487E+09 0.572767E+10 0.00 4.59
April 0.202302E+11 0.00 0.00 24365919.68 0.00 0.00 0.190393E+11 0.00 4.63
May 0.134617E+11 0.00 0.00 21892130.96 0.00 0.00 0.236649E+11 0.00 4.65
June 0.802984E+10 3539366.27 0.00 26296356.79 0.00 0.00 0.211129E+11 0.00 4.83
July 0.831758E+10 14376749.15 0.00 25980441.04 0.00 0.00 0.197043E+11 0.00 4.86
August 0.112993E+11 0.00 0.00 24999053.63 0.00 0.00 0.218882E+11 0.00 4.83
September 0.232065E+11 0.00 0.00 10018429.37 0.00 0.00 0.137997E+11 0.00 4.46
October 0.378713E+11 0.00 0.00 2422134.25 0.00 0.252545E+09 0.289445E+10 0.00 4.50
November 0.511786E+11 0.00 0.00 0.00 0.00 0.213714E+11 0.00 0.00 4.69
December 0.469358E+11 0.00 0.00 0.00 0.00 0.370054E+11 0.00 0.00 4.75
                   
Annual Sum or Average 0.374190E+12 17916115.42 0.00 0.139942E+09 0.00 0.956082E+11 0.128086E+12 0.00 4.68
Minimum of Months 0.802984E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.46
Maximum of Months 0.579133E+11 14376749.15 0.00 26296356.79 0.00 0.370054E+11 0.236649E+11 0.00 4.86



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: LOBBY_FLR_1

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.182648E+12 0.00 0.00 0.00 0.00 0.164797E+11 0.00 0.00 1.78
February 0.171764E+12 0.00 0.00 0.00 0.00 0.289401E+09 0.00 0.00 1.75
March 0.137070E+12 0.00 0.00 452633.15 0.00 0.00 0.228349E+10 0.00 1.72
April 0.613668E+11 0.00 0.00 45100158.56 0.00 0.00 0.388004E+11 0.00 1.70
May 0.313262E+11 0.00 0.00 99826887.26 0.00 0.00 0.675633E+11 0.00 1.77
June 0.149694E+11 8452157.41 0.00 0.104516E+09 79381.27 0.00 0.646606E+11 0.00 1.90
July 0.138393E+11 35428964.01 0.00 0.104423E+09 0.00 0.00 0.629731E+11 0.00 1.90
August 0.227665E+11 0.00 0.00 99537376.01 0.00 0.00 0.660091E+11 0.00 1.85
September 0.522031E+11 0.00 0.00 53601357.63 0.00 0.00 0.446463E+11 0.00 1.68
October 0.979024E+11 0.00 0.00 6702431.54 0.00 0.00 0.877659E+10 0.00 1.69
November 0.184160E+12 0.00 0.00 0.00 0.00 0.443707E+10 0.00 0.00 1.76
December 0.191675E+12 0.00 0.00 0.00 0.00 0.264281E+11 0.00 0.00 1.78
                   
Annual Sum or Average 0.116169E+13 43881121.42 0.00 0.514160E+09 79381.27 0.476342E+11 0.355713E+12 0.00 1.77
Minimum of Months 0.138393E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.68
Maximum of Months 0.191675E+12 35428964.01 0.00 0.104516E+09 79381.27 0.264281E+11 0.675633E+11 0.00 1.90



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_1_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 58559860.98 0.00 0.00 18104.88 0.00 0.384899E+10 1718660.58 0.00 0.48
February 0.122213E+09 0.00 0.00 84165.40 0.00 0.328662E+10 3931650.32 0.00 0.47
March 0.370735E+09 0.00 0.00 798460.41 0.00 0.215271E+10 53364748.46 0.00 0.47
April 0.330633E+09 0.00 0.00 13998234.14 0.00 0.712505E+09 0.724675E+09 0.00 0.48
May 0.218079E+09 0.00 0.00 17706877.70 0.00 92520610.43 0.139043E+10 0.00 0.48
June 0.143557E+09 4726233.07 0.00 19699945.36 74834.81 1790551.07 0.109732E+10 0.00 0.48
July 0.128984E+09 14277255.03 0.00 15479711.99 198951.32 1587701.64 0.959920E+09 0.00 0.48
August 0.206202E+09 1105216.72 0.00 15097689.95 31894.20 51790029.92 0.113813E+10 0.00 0.47
September 0.399659E+09 0.00 0.00 5211153.31 0.00 0.628551E+09 0.636999E+09 0.00 0.48
October 0.279132E+09 0.00 0.00 416640.28 0.00 0.149537E+10 41997905.67 0.00 0.47
November 60518915.45 0.00 0.00 20537.04 0.00 0.363276E+10 2665929.20 0.00 0.47
December 52336825.24 0.00 0.00 13023.02 0.00 0.432580E+10 929962.51 0.00 0.47
                   
Annual Sum or Average 0.237061E+10 20108704.82 0.00 88544543.49 305680.33 0.202310E+11 0.605208E+10 0.00 0.47
Minimum of Months 52336825.24 0.00 0.00 13023.02 0.00 1587701.64 929962.51 0.00 0.47
Maximum of Months 0.399659E+09 14277255.03 0.00 19699945.36 198951.32 0.432580E+10 0.139043E+10 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_2_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 52919522.11 0.00 0.00 20923.61 0.00 0.385451E+10 1377582.62 0.00 0.48
February 57380397.18 0.00 0.00 65080.55 0.00 0.335239E+10 2612082.60 0.00 0.47
March 0.158619E+09 0.00 0.00 205451.75 0.00 0.239897E+10 19519035.78 0.00 0.47
April 0.412759E+09 0.00 0.00 7198721.54 0.00 0.921807E+09 0.439837E+09 0.00 0.47
May 0.394499E+09 0.00 0.00 13542677.32 0.00 0.145300E+09 0.116520E+10 0.00 0.47
June 0.180130E+09 4632564.01 0.00 18067890.21 167941.36 1899936.39 0.106212E+10 0.00 0.48
July 0.162617E+09 13946466.19 0.00 13803264.75 528044.05 1623309.13 0.927798E+09 0.00 0.48
August 0.310513E+09 1103146.82 0.00 11157016.46 33830.88 77908872.68 0.101147E+10 0.00 0.47
September 0.460266E+09 0.00 0.00 2183362.11 0.00 0.839810E+09 0.367965E+09 0.00 0.47
October 0.196090E+09 0.00 0.00 225786.33 0.00 0.160762E+10 12772587.02 0.00 0.47
November 50245139.17 0.00 0.00 16033.77 0.00 0.364403E+10 1239496.88 0.00 0.47
December 50873125.14 0.00 0.00 14931.02 0.00 0.432683E+10 854896.28 0.00 0.47
                   
Annual Sum or Average 0.248691E+10 19682177.02 0.00 66501139.43 729816.29 0.211727E+11 0.501276E+10 0.00 0.47
Minimum of Months 50245139.17 0.00 0.00 14931.02 0.00 1623309.13 854896.28 0.00 0.47
Maximum of Months 0.460266E+09 13946466.19 0.00 18067890.21 528044.05 0.432683E+10 0.116520E+10 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_3_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.639171E+09 0.00 0.00 0.00 0.00 0.523673E+11 0.00 0.00 0.54
February 0.592497E+10 0.00 0.00 0.00 0.00 0.403502E+11 0.00 0.00 0.53
March 0.196728E+11 0.00 0.00 4996439.03 0.00 0.137955E+11 0.147684E+10 0.00 0.53
April 0.142889E+11 0.00 0.00 0.129095E+09 0.00 0.00 0.974173E+10 0.00 0.54
May 0.763783E+10 0.00 0.00 0.116685E+09 0.00 0.00 0.155501E+11 0.00 0.54
June 0.209242E+10 65098174.50 0.00 0.119265E+09 0.00 0.00 0.149048E+11 0.00 0.54
July 0.236012E+10 0.196284E+09 0.00 0.109509E+09 0.00 0.00 0.125263E+11 0.00 0.54
August 0.427174E+10 15418204.26 0.00 0.121583E+09 0.00 0.00 0.147415E+11 0.00 0.54
September 0.144265E+11 0.00 0.00 53383252.15 0.00 0.122584E+09 0.804688E+10 0.00 0.54
October 0.134164E+11 0.00 0.00 5369537.00 0.00 0.104654E+11 0.748675E+09 0.00 0.54
November 0.112728E+10 0.00 0.00 0.00 0.00 0.489867E+11 0.00 0.00 0.53
December 0.00 0.00 0.00 0.00 0.00 0.593764E+11 0.00 0.00 0.53
                   
Annual Sum or Average 0.858581E+11 0.276801E+09 0.00 0.659886E+09 0.00 0.225464E+12 0.777369E+11 0.00 0.54
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.53
Maximum of Months 0.196728E+11 0.196284E+09 0.00 0.129095E+09 0.00 0.593764E+11 0.155501E+11 0.00 0.54



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_4_MULT19_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.426926E+10 0.00 0.00 450030.63 0.00 0.487084E+11 42881074.20 0.00 0.54
February 0.462592E+10 0.00 0.00 670234.57 0.00 0.416102E+11 51029013.58 0.00 0.53
March 0.648089E+10 0.00 0.00 1745564.89 0.00 0.276579E+11 0.819124E+09 0.00 0.54
April 0.682051E+10 0.00 0.00 33265353.43 0.00 0.817553E+10 0.913706E+10 0.00 0.54
May 0.672770E+10 0.00 0.00 0.127492E+09 0.00 49952435.52 0.164058E+11 0.00 0.54
June 0.466018E+10 40566851.55 0.00 0.145560E+09 24549123.92 10296142.32 0.123052E+11 0.00 0.54
July 0.334615E+10 0.133871E+09 301366.02 0.123876E+09 62155806.12 12809708.22 0.115172E+11 10065.81 0.54
August 0.498984E+10 13009684.05 0.00 0.102339E+09 2412736.29 38228523.69 0.140096E+11 0.00 0.54
September 0.648043E+10 0.00 0.00 51766182.77 0.00 0.231599E+10 0.138074E+11 0.00 0.54
October 0.587854E+10 0.00 0.00 8770034.74 0.00 0.150186E+11 0.373666E+10 0.00 0.54
November 0.416589E+10 0.00 0.00 430069.91 0.00 0.459235E+11 37894603.17 0.00 0.54
December 0.379881E+10 0.00 0.00 372350.44 0.00 0.555642E+11 29229806.06 0.00 0.54
                   
Annual Sum or Average 0.622441E+11 0.187447E+09 301366.02 0.596736E+09 89117666.33 0.245086E+12 0.818991E+11 10065.81 0.54
Minimum of Months 0.334615E+10 0.00 0.00 372350.44 0.00 10296142.32 29229806.06 0.00 0.53
Maximum of Months 0.682051E+10 0.133871E+09 301366.02 0.145560E+09 62155806.12 0.555642E+11 0.164058E+11 10065.81 0.54



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_5_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 62723812.24 0.00 0.00 21465.87 0.00 0.384490E+10 1647723.09 0.00 0.48
February 0.162086E+09 0.00 0.00 111416.84 0.00 0.324445E+10 6206336.53 0.00 0.47
March 0.455591E+09 0.00 0.00 1028401.55 0.00 0.198322E+10 0.137771E+09 0.00 0.47
April 0.261894E+09 0.00 0.00 13521849.77 0.00 0.695490E+09 0.810905E+09 0.00 0.48
May 0.114827E+09 0.00 0.00 28338361.39 0.00 64495287.05 0.151108E+10 0.00 0.48
June 80996213.84 4712615.07 0.00 25403069.73 88452.81 1044151.44 0.115492E+10 0.00 0.48
July 73757387.04 14291835.72 0.00 21962603.50 184370.62 1197276.29 0.100905E+10 0.00 0.48
August 0.134396E+09 1095760.76 0.00 20800738.98 41350.17 38460890.36 0.121756E+10 0.00 0.47
September 0.323955E+09 0.00 0.00 8770137.39 0.00 0.547072E+09 0.790623E+09 0.00 0.48
October 0.315837E+09 0.00 0.00 911971.21 0.00 0.139747E+10 0.102705E+09 0.00 0.47
November 61738468.23 0.00 0.00 22447.44 0.00 0.363180E+10 2406382.34 0.00 0.47
December 53138870.73 0.00 0.00 14775.84 0.00 0.432500E+10 928209.69 0.00 0.47
                   
Annual Sum or Average 0.210094E+10 20100211.55 0.00 0.120907E+09 314173.60 0.197746E+11 0.674580E+10 0.00 0.47
Minimum of Months 53138870.73 0.00 0.00 14775.84 0.00 1044151.44 928209.69 0.00 0.47
Maximum of Months 0.455591E+09 14291835.72 0.00 28338361.39 184370.62 0.432500E+10 0.151108E+10 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_6_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 56521231.28 0.00 0.00 23312.24 0.00 0.385057E+10 1717567.31 0.00 0.48
February 76425756.85 0.00 0.00 80557.75 0.00 0.333180E+10 4139332.33 0.00 0.47
March 0.315623E+09 0.00 0.00 339643.85 0.00 0.221083E+10 50521196.23 0.00 0.47
April 0.400857E+09 0.00 0.00 5815483.01 0.00 0.878197E+09 0.496733E+09 0.00 0.48
May 0.155440E+09 0.00 0.00 23788583.02 0.00 0.101840E+09 0.143747E+10 0.00 0.48
June 94375924.13 4700227.67 0.00 23810911.01 100277.69 1542573.58 0.114249E+10 0.00 0.48
July 84654204.04 14246552.92 0.00 20252739.45 227957.32 1034696.56 0.999900E+09 0.00 0.48
August 0.192747E+09 1081435.92 0.00 16232000.61 55541.77 56556203.78 0.114551E+10 0.00 0.47
September 0.442300E+09 0.00 0.00 4746940.73 0.00 0.684648E+09 0.538530E+09 0.00 0.48
October 0.255395E+09 0.00 0.00 347101.13 0.00 0.152540E+10 35567105.68 0.00 0.47
November 52232810.04 0.00 0.00 17790.94 0.00 0.364152E+10 1760742.30 0.00 0.47
December 51489536.98 0.00 0.00 16639.76 0.00 0.432605E+10 1010559.37 0.00 0.47
                   
Annual Sum or Average 0.217806E+10 20028216.52 0.00 95471703.51 383776.79 0.206100E+11 0.585535E+10 0.00 0.47
Minimum of Months 51489536.98 0.00 0.00 16639.76 0.00 1034696.56 1010559.37 0.00 0.47
Maximum of Months 0.442300E+09 14246552.92 0.00 23810911.01 227957.32 0.432605E+10 0.143747E+10 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORRIDOR_FLR_3

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.495404E+10 0.00 0.00 0.00 0.00 0.588226E+11 0.00 0.00 0.62
February 0.131610E+11 0.00 0.00 0.00 0.00 0.419422E+11 0.00 0.00 0.61
March 0.322039E+11 0.00 0.00 0.00 0.00 0.124268E+11 0.00 0.00 0.60
April 0.313649E+11 0.00 0.00 0.00 0.00 0.358409E+09 0.00 0.00 0.59
May 0.303173E+11 0.00 0.00 8723.45 0.00 0.00 63897993.46 0.00 0.60
June 0.199293E+11 0.00 0.00 4603424.38 2732384.64 0.00 0.415993E+10 0.00 0.63
July 0.203184E+11 5681203.13 0.00 4764532.98 5391684.40 0.00 0.294695E+10 0.00 0.63
August 0.264932E+11 0.00 0.00 592042.12 0.00 0.00 0.704542E+09 0.00 0.61
September 0.305223E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.58
October 0.270533E+11 0.00 0.00 0.00 0.00 0.705262E+10 0.00 0.00 0.59
November 0.594067E+10 0.00 0.00 0.00 0.00 0.544611E+11 0.00 0.00 0.62
December 0.188022E+10 0.00 0.00 0.00 0.00 0.679690E+11 0.00 0.00 0.62
                   
Annual Sum or Average 0.244139E+12 5681203.13 0.00 9968722.93 8124069.04 0.243033E+12 0.787532E+10 0.00 0.61
Minimum of Months 0.188022E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.58
Maximum of Months 0.322039E+11 5681203.13 0.00 4764532.98 5391684.40 0.679690E+11 0.415993E+10 0.00 0.63



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_1_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 9320093.18 0.00 0.00 0.00 0.00 0.968002E+09 0.00 0.00 0.48
February 14628137.70 0.00 0.00 1898.95 0.00 0.838361E+09 221359.19 0.00 0.47
March 66038654.16 0.00 0.00 136431.84 0.00 0.566203E+09 12024603.43 0.00 0.47
April 81847580.42 0.00 0.00 3312993.76 0.00 0.217170E+09 0.143122E+09 0.00 0.48
May 59819364.29 0.00 0.00 3708907.36 0.00 65001558.33 0.301155E+09 0.00 0.47
June 38090449.52 1181558.27 0.00 4533892.93 18708.70 4562929.54 0.268404E+09 0.00 0.48
July 35174835.88 3569822.57 0.00 3494871.65 49229.01 6319763.00 0.231503E+09 0.00 0.48
August 55957329.92 276304.18 0.00 3281872.13 7973.55 30571716.27 0.262993E+09 0.00 0.47
September 99965642.92 0.00 0.00 976323.66 0.00 0.218236E+09 98427180.60 0.00 0.47
October 51417264.32 0.00 0.00 57984.87 0.00 0.397359E+09 5395765.05 0.00 0.47
November 9655579.61 0.00 0.00 0.00 0.00 0.914336E+09 0.00 0.00 0.47
December 8267011.05 0.00 0.00 12.07 0.00 0.108649E+10 11733.35 0.00 0.47
                   
Annual Sum or Average 0.530182E+09 5027685.02 0.00 19505189.21 75911.26 0.531262E+10 0.132326E+10 0.00 0.47
Minimum of Months 8267011.05 0.00 0.00 0.00 0.00 4562929.54 0.00 0.00 0.47
Maximum of Months 99965642.92 3569822.57 0.00 4533892.93 49229.01 0.108649E+10 0.301155E+09 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_2_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 8818416.42 0.00 0.00 0.00 0.00 0.968390E+09 0.00 0.00 0.48
February 8863523.83 0.00 0.00 1344.70 0.00 0.844082E+09 165324.30 0.00 0.47
March 22491405.03 0.00 0.00 22653.39 0.00 0.620924E+09 888948.02 0.00 0.47
April 90552953.89 0.00 0.00 1581612.56 0.00 0.269811E+09 83454615.09 0.00 0.47
May 0.103191E+09 0.00 0.00 2592439.69 0.00 85344972.23 0.238506E+09 0.00 0.47
June 48571814.36 1157878.95 0.00 4048028.00 42247.39 4309981.02 0.258624E+09 0.00 0.48
July 43648942.57 3455101.27 0.00 3028742.41 163526.29 5857091.22 0.223926E+09 0.00 0.48
August 79297765.13 275786.70 0.00 2264181.62 8457.72 43584292.00 0.227616E+09 0.00 0.47
September 0.104155E+09 0.00 0.00 373417.36 0.00 0.258496E+09 54532157.82 0.00 0.47
October 36086504.75 0.00 0.00 30140.03 0.00 0.417017E+09 1042998.40 0.00 0.47
November 8666447.62 0.00 0.00 0.00 0.00 0.915217E+09 0.00 0.00 0.47
December 8125181.40 0.00 0.00 107.71 0.00 0.108651E+10 11636.33 0.00 0.47
                   
Annual Sum or Average 0.562469E+09 4888766.92 0.00 13942667.46 214231.41 0.551954E+10 0.108877E+10 0.00 0.47
Minimum of Months 8125181.40 0.00 0.00 0.00 0.00 4309981.02 0.00 0.00 0.47
Maximum of Months 0.104155E+09 3455101.27 0.00 4048028.00 163526.29 0.108651E+10 0.258624E+09 0.00 0.48



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: ROOM_3_MULT9_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.226717E+09 0.00 0.00 30659.18 0.00 0.604974E+10 2308115.55 0.00 0.54
February 0.534406E+09 0.00 0.00 716287.08 0.00 0.483856E+10 0.107774E+09 0.00 0.54
March 0.507526E+09 0.00 0.00 7169131.15 0.00 0.303037E+10 0.594898E+09 0.00 0.54
April 0.318351E+09 0.00 0.00 31991474.32 0.00 0.892048E+09 0.161941E+10 0.00 0.54
May 0.279730E+09 0.00 0.00 28959670.37 0.00 95928485.19 0.235589E+10 0.00 0.54
June 0.227702E+09 7557397.49 0.00 27321557.48 153704.87 3520594.60 0.176897E+10 0.00 0.54
July 0.205004E+09 22938603.31 0.00 23633596.77 311955.03 2963840.13 0.154472E+10 0.00 0.54
August 0.272937E+09 1772248.81 0.00 27500661.93 54090.44 52287431.40 0.191386E+10 0.00 0.54
September 0.470099E+09 0.00 0.00 16880023.53 0.00 0.627842E+09 0.156808E+10 0.00 0.54
October 0.521389E+09 0.00 0.00 4448094.95 0.00 0.197972E+10 0.412636E+09 0.00 0.54
November 0.260347E+09 0.00 0.00 80761.71 0.00 0.566163E+10 14111965.56 0.00 0.54
December 0.107141E+09 0.00 0.00 17395.68 0.00 0.692497E+10 1206361.10 0.00 0.54
                   
Annual Sum or Average 0.393135E+10 32268249.61 0.00 0.168749E+09 519750.34 0.301596E+11 0.119039E+11 0.00 0.54
Minimum of Months 0.107141E+09 0.00 0.00 17395.68 0.00 2963840.13 1206361.10 0.00 0.54
Maximum of Months 0.534406E+09 22938603.31 0.00 31991474.32 311955.03 0.692497E+10 0.235589E+10 0.00 0.54



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: BANQUET_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.456068E+11 0.00 0.00 18594934.40 0.00 0.00 0.336617E+11 0.00 3.68
February 0.363317E+11 0.00 0.00 19512204.03 0.00 0.00 0.326341E+11 0.00 3.65
March 0.174554E+11 0.00 0.00 34769093.53 0.00 0.00 0.400926E+11 0.00 3.69
April 0.332500E+10 0.00 0.00 85626041.79 0.00 0.00 0.429445E+11 0.00 4.02
May 0.137394E+09 0.00 0.00 0.137386E+09 0.00 0.00 0.510392E+11 0.00 4.61
June 0.00 3657109.24 0.00 0.108974E+09 0.00 0.00 0.433049E+11 0.00 5.18
July 0.00 17610664.16 0.00 0.106328E+09 0.00 0.00 0.419582E+11 0.00 5.15
August 0.251118E+09 0.00 0.00 0.105102E+09 0.00 0.00 0.459063E+11 0.00 4.83
September 0.158211E+10 0.00 0.00 0.117160E+09 0.00 0.00 0.460244E+11 0.00 4.17
October 0.903800E+10 0.00 0.00 60237045.97 0.00 0.00 0.375866E+11 0.00 3.80
November 0.409766E+11 0.00 0.00 17745463.88 0.00 0.00 0.342151E+11 0.00 3.63
December 0.492208E+11 0.00 0.00 14564175.88 0.00 0.00 0.372999E+11 0.00 3.65
                   
Annual Sum or Average 0.203925E+12 21267773.40 0.00 0.825999E+09 0.00 0.00 0.486667E+12 0.00 4.18
Minimum of Months 0.00 0.00 0.00 14564175.88 0.00 0.00 0.326341E+11 0.00 3.63
Maximum of Months 0.492208E+11 17610664.16 0.00 0.137386E+09 0.00 0.00 0.510392E+11 0.00 5.18



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: DINING_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.422299E+11 0.00 0.00 26756107.17 0.00 0.00 0.417384E+11 0.00 3.92
February 0.307037E+11 0.00 0.00 27690554.58 0.00 0.00 0.425612E+11 0.00 3.90
March 0.119225E+11 0.00 0.00 48477448.26 0.00 0.00 0.501791E+11 0.00 4.01
April 0.109661E+10 0.00 0.00 0.108593E+09 0.00 0.00 0.496105E+11 0.00 4.40
May 6998717.08 0.00 0.00 0.156636E+09 0.00 0.00 0.555779E+11 0.00 5.01
June 0.00 3992399.37 0.00 0.117784E+09 0.00 0.00 0.463942E+11 0.00 5.56
July 0.00 18995311.04 0.00 0.115241E+09 0.00 0.00 0.448973E+11 0.00 5.52
August 0.137180E+09 0.00 0.00 0.117629E+09 0.00 0.00 0.496627E+11 0.00 5.22
September 0.349956E+09 0.00 0.00 0.145469E+09 0.00 0.00 0.519732E+11 0.00 4.58
October 0.491914E+10 0.00 0.00 80188774.88 0.00 0.00 0.460688E+11 0.00 4.16
November 0.361828E+11 0.00 0.00 25729989.54 0.00 0.00 0.434993E+11 0.00 3.87
December 0.433702E+11 0.00 0.00 21786740.08 0.00 0.00 0.478909E+11 0.00 3.87
                   
Annual Sum or Average 0.170919E+12 22987710.41 0.00 0.991982E+09 0.00 0.00 0.570054E+12 0.00 4.51
Minimum of Months 0.00 0.00 0.00 21786740.08 0.00 0.00 0.417384E+11 0.00 3.87
Maximum of Months 0.433702E+11 18995311.04 0.00 0.156636E+09 0.00 0.00 0.555779E+11 0.00 5.56



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: KITCHEN_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.365052E+10 0.00 0.00 95235191.16 0.00 10433703.17 0.107672E+12 0.00 17.49
February 0.119761E+10 0.00 0.00 93105757.66 0.00 0.00 0.980979E+11 0.00 17.83
March 0.202552E+09 0.00 0.00 0.118839E+09 0.00 0.00 0.881248E+11 0.00 18.98
April 0.00 0.00 0.00 0.201959E+09 0.00 0.00 0.700387E+11 0.00 19.69
May 7576840.41 0.00 0.00 0.207623E+09 0.00 0.00 0.700686E+11 0.00 21.36
June 0.00 7602431.08 0.00 0.148010E+09 0.00 0.00 0.543242E+11 0.00 22.64
July 1826145.50 30783372.07 0.00 0.148224E+09 0.00 0.00 0.509730E+11 0.00 22.61
August 13504552.44 0.00 0.00 0.164393E+09 0.00 0.00 0.606164E+11 0.00 21.89
September 41214019.57 0.00 0.00 0.222621E+09 0.00 0.00 0.682216E+11 0.00 19.86
October 10595262.15 0.00 0.00 0.154516E+09 0.00 0.00 0.716530E+11 0.00 18.86
November 0.592927E+09 0.00 0.00 95789044.70 0.00 0.00 0.106486E+12 0.00 17.38
December 0.952035E+09 0.00 0.00 94562473.77 0.00 0.00 0.120215E+12 0.00 17.15
                   
Annual Sum or Average 0.667037E+10 38385803.15 0.00 0.174488E+10 0.00 10433703.17 0.966492E+12 0.00 19.66
Minimum of Months 0.00 0.00 0.00 93105757.66 0.00 0.00 0.509730E+11 0.00 17.15
Maximum of Months 0.365052E+10 30783372.07 0.00 0.222621E+09 0.00 10433703.17 0.120215E+12 0.00 22.64



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORRIDOR_FLR_6

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 97268351.97 0.00 0.00 0.00 0.00 0.315237E+11 0.00 0.00 1.17
February 0.203985E+10 0.00 0.00 0.00 0.00 0.252828E+11 0.00 0.00 1.15
March 0.950696E+10 0.00 0.00 0.00 0.00 0.126230E+11 0.00 0.00 1.12
April 0.143290E+11 0.00 0.00 0.00 0.00 0.140088E+10 0.00 0.00 1.10
May 0.143192E+11 0.00 0.00 635411.63 0.00 0.00 0.746933E+09 0.00 1.11
June 0.856311E+10 1555246.62 0.00 6306330.87 0.00 0.00 0.341274E+10 0.00 1.19
July 0.879712E+10 5910403.23 0.00 6964219.69 0.00 0.00 0.275379E+10 0.00 1.19
August 0.121437E+11 0.00 0.00 2628874.64 0.00 0.00 0.135894E+10 0.00 1.15
September 0.151343E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.08
October 0.106715E+11 0.00 0.00 0.00 0.00 0.623975E+10 0.00 0.00 1.10
November 0.122429E+09 0.00 0.00 0.00 0.00 0.298275E+11 0.00 0.00 1.15
December 91430964.73 0.00 0.00 0.00 0.00 0.345429E+11 0.00 0.00 1.17
                   
Annual Sum or Average 0.958159E+11 7465649.84 0.00 16534836.82 0.00 0.141441E+12 0.827241E+10 0.00 1.14
Minimum of Months 91430964.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.08
Maximum of Months 0.151343E+11 5910403.23 0.00 6964219.69 0.00 0.345429E+11 0.341274E+10 0.00 1.19



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2023-10-16 08:59:07

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January -0.249282E+11 0.354793E+11 0.421778E+12 0.170627E+13 0.236126E+12
February 0.302985E+11 0.305896E+11 0.357320E+12 0.146709E+13 0.196354E+12
March 0.196924E+12 0.297454E+11 0.348664E+12 0.146087E+13 0.156637E+12
April 0.373568E+12 0.199187E+11 0.236343E+12 0.103487E+13 0.124268E+12
May 0.495458E+12 0.122585E+11 0.141724E+12 0.668672E+12 0.213336E+12
June 0.512425E+12 0.765462E+10 0.881674E+11 0.431906E+12 0.396612E+12
July 0.456127E+12 0.691770E+10 0.819864E+11 0.410692E+12 0.457002E+12
August 0.336057E+12 0.921391E+10 0.109552E+12 0.518811E+12 0.312255E+12
September 0.147079E+12 0.147172E+11 0.184908E+12 0.792758E+12 0.999845E+11
October 0.564420E+11 0.234803E+11 0.292322E+12 0.119666E+13 0.108185E+12
November -0.312735E+10 0.345612E+11 0.407187E+12 0.166236E+13 0.222407E+12
December -0.374375E+11 0.369146E+11 0.433353E+12 0.176151E+13 0.257575E+12
           
Annual Sum or Average 0.253889E+13 0.261451E+12 0.310330E+13 0.131125E+14 0.278074E+13
Minimum of Months -0.374375E+11 0.691770E+10 0.819864E+11 0.410692E+12 0.999845E+11
Maximum of Months 0.512425E+12 0.369146E+11 0.433353E+12 0.176151E+13 0.457002E+12